Loading...
HomeMy WebLinkAbout60 Keyes Ct 94-1924CERTIFICATE OF OCCUPANCY / COMPLETION This is to certify that the building located at 90 KEYES CT for which permit 94- 00001924 has heretofore been issued on 7/22/94 has been completed according to plans and specifications filed in the office of the Buildin OffiFial�rior to the issuance of said building permit, to wit as �'lA•l k4T ;u-(-, complies with all the building, plumbing, electrical, zoning and subdivision regulations ordinances of the City of Sanford and with the provisions of these regulations. STAFF APPROVAL Subdivision Regulations Apply: Yes No _ DATE APPROVAL DATE APPROVAL BUILDING: FIRE: Finaled Inspected ZONING- Inspected UTILITIES: Water Sewer Lines In / Lines In Meter yu fi Sewer Set z`l���r'' Tap�%;��;_ Reclaimed Water ENGINEERING: Street Drainage z ZG �'S Paved Maintenance !( Bond PUBLIC WORKS: Street Name / Street Signs Lights Storm / r Sewer Drivewa y Street / Z •� /��' S Work DESCRIPTION WATER -SEWER IMPACT FEES 01- APPLCTN FEE - BUILDING 01 -FIRE IMPACT - NONRES 01 -FIRE INSPECT -NEW CONST 01- POLICE IMPACT - NONRES 01 -RADON GAS TAX FEE 01 -ROAD IMPACT FEES 01- RECOVERY FD /CERT. PGM_ OWNER DATE AMOUNT PN =7 /IXas 49�SZ7 213 7/22/94 10.00 7/22/94 19.95 7/22/94 159.60 7/22/94 119.70 7/22/94 39.90 7/22/94 5331.34 7/22/94 39.90 BUILDING OFFICIAL / DATE j Law & Associates, Inc. ® Geotechnical & Environmental Services Telephone: 407 / 246 -1880 & Construction Materials Testing Fax: 407 / 246 -1940 November 15, 1994 At Cost Construction Co. P.O. Box 400 Altamonte Springs, Florida 32715 Attention: Mr. Sandford Butler Subject: TESTING OF A -325 BOLT TORQUE ON STEEL STRUCTURE, 60 KEYES COURT, SEMINOLE COUNTY, FLORIDA (LA94 -02.090) Dear Mr. Butler: Law & Associates, Inc. is pleased to present this report on the bolt torque inspection at the subject project. This report presents the results of our tests performed on November 11, 1994. BOLT TOROUE A random check of A -325 bolt torque was performed on site. Bolts on beam to column, column to floor slab and other connections were tested for minimum torque value using an OTC 7176 calibrated torque wrench. All bolts tested met or exceeded a minimum torque of 350 foot pounds. The installation of the bolts and the subsequent torquing procedure was performed using the turn of the nut procedure. Based upon the on -site testing and to the best of our knowledge, we believe that the A -325 structural steel bolts have been installed to meet minimum design criteria. CLOSURE Law & Associates, Inc. appreciates the opportunity to provide our services on this assignment and trust that the information provided herein is sufficient for your present needs. Should you have any questions of if we can be of further assistance, please do not hesitate to contact us. Sincerely, LAW & A SSOICIAMt. INC. President No. 1650 Acme Street • Orlando, Florida • 32805 /