Loading...
HomeMy WebLinkAbout1771 WP Ball Blvd 12-377 (fr alarm elec)_ f 1 � ,a 0\ I NOV S Zip BY: _ Application No: t P":3q I Job Address: 1771 W.P. BALL BLVD Parcel ID: 32- 19 -30- 507 - 0000 -0090 Zoning: Description of Work: Adding power supply, notificai, ,)n devices, and connecting to existing panel. Plan Review Contact Person: Brian Corton Title: Eng 11 Phone. 407- 830 -6500 Fax: 407 - 478 -2385 E -mail: brian.corton @dynafire.com CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Docume .t d Construction Value: $ 8155.00 Historic District: Yes ❑ No ❑ Name WRI Seminole II LLC Street: P.O. Box 3467 Property Owner Information Phone: Resident of property? City, State Zip: Houston, Tx. 77253 Name DynaFire, Inc. Street: 109B Concord Drive Contractor Information Phone: 407 - 830 -6500 Fax: 407 -478 -2385 City, State Zip: Casselberry, Fl. 32707 State License No.: EF20000528 Name: Street: City, St, Zip: Bonding Company: Address: Building Permit ❑ Square Footage: _ Architect/Engineer Information Phone: Fax: E -mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: No. of Stories: No. of Dwelling Units: Flood Zone: Electrical ❑ New Service — No. of AMPS: Mechanical ❑ (Duct layout required for new systems) Plumbing ❑ New Construction - No. of Fixtures: Fire Sprinkle /Alarm 11 No. of heads: _b/ 0 Application is hereby made to obtain a permit to do tl:; work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit�/vill�be appl' your permit fees when the permit is released. �� Signature of Owner /Agent Date Print Owner /Agent's Name Signature of Notary-State of Florida Date Owner /Agent is Personally Known to Me or Produced ID Type of ID APPROVALS: ZONING: ENGINEERING: COMMENTS: Rev 11.08 Date ,a, Ye KRISTYN S WELCH MY COMMISSION # DD845564 ''�dctti EXPIRES January 05, 2013 (407) 398 -0153 Florida oteryService.com Contractor /Agent is Personally Known to Me or Produced ID Type of ID UTILITIES: ---WASTE WATER: FIRE: UILDING:_ Sanford City oy U i I g -ER–F- . 4 We rever 10ii IV 91 ofi Fire Plan Review Service Fees Jel: 407.688.5050 Fax: 407,688.5051 Date: Permit 9- 117 Business or Project Name: Address: Contact Name: Contact Ph: Plan Revlelnr Information ❑ Construction ❑ ce� Fib ❑ Fire Sprinkler ❑ Hood ❑ Tank ❑ Paint Booth ■ S-c DynaFire Inc.. 109 Concord Drive Casselberry, FL 32707 Phone: 407 - 830 -6500 — Fag: 407 - 478 -2385 E -mail: engineering @dynafire.com TO: City of Sanford ATTN: Permitting Services DATE: November 22, 2011 FROM: Brian Corton RE: Shoe Carnival Should you require anything else, please contact me. Thank you, Brian Corton Engineering Dept. DynaFire Inc. 109B Concord Drive Casselberry, Fl. 32707 Ph.:407- 830 -6500 ext.109 Cell: 407 - 383 -4748 Fax: 407-478-2385 "Large Enough to Deliver, Yet Small Enough to Care" BUILDING PERMITS 24 HOUR NOTICE REQUIPFn 300 N PARK AV SANFORD, FOR ALL INSPECT FL 32771 PHONE 407.688.5151 ----------------- " ------ --- --- ----- - - - - -- _______ Application Number 12- 00000105 - - - -- Application pin number . 11/08/11 Property Address ' . Parcel Number _� � 1 1771 771 W WP BALL BLVD , Application t 32.19.30.507- 0000 -0090 Subdivision Name description INTERIOR COMMERCIAL REMODELING Property Zoning . , _ _ _ Application valuation . PUD • - 148000 Owner --- ----------- - - - - -- Contractor Weingarten Realty Investors ------------------------ R D MICHAELS INC 1111 N KENTUCKY AVE WINTER PARK FL 32789 -------- --- --- (407) 831 -1110 Structure Information 000 000 - - -___ Construction Type . , Occupancy Type . ' TYPE 1113 Other struct info MERCANTILE USE GROUP • - NUMBER OF STORIES SQUARE FOOTAGE 1.00 --------------------- 17007.00 Permit ------------------ ELECTRIC PERMIT -ALTER /ADD /FIX --------------- ----- Additional desc 400 AMP SERVICE Sub Contractor ELECTRIC SERVICE GROUP LLC Permit Fee . . . Issue Date 430 00 . 11430.00 Expiration Date 5/06/12 Valuation 79720 Qty Unit Charge Per BASE FEE Extension - - - - -- 80.00 - - -- - -- 5.0000 -THOU ELEC PERMIT -ORD 4137 11.24,08 30.00 -------- ---- - - - - -- 400.00 Special Notes and Comments ------- - - - - -- -------- - - - - -_ All sub- contractors shall pull their Own permits. P11 projects within the City shall use WastePrO for debris removal. Please contact WastePro at 407.774.0800. noc on file exp 17..02.:12 RIS $0 October 17, 2011 4:53c18 PM Maker. Water impact fee $2350.25 - - _ - -Sewer service is by Seminole County. Other Fees - ---- - - - - -- 01- APPLCTN FEE-FIECTRIC----------------- 01- APPLCTN FEE - BUILDING 25.00 25.00 01 -BLDG PLAN REVIEW 01 /RPR -FIRE INSPECT -AL 444.00 WD IMPACT: COMMERCIAL 850.00 01 -BLDG DCA SURCHARGE 2350.25 O1 -BLDG DBPR SURCHARGE 30.38 - _ - -- ---- ------- - - - - -- 30.38 --------------- - Fee summa ------- - - - - -- -Due ry Charged Paid --- - - - --- - ---------------- Credited Permit Fee Total 00 Other Fee Total 430.00 .00 3755.01 3715.61 430.00 0-Z—d Total 4185..01 39.40 3715.61 _ .00 469.40 - - - -- - - ------------------ F2LTLURE TO COMPLY WITH MECHANIC, --- ---- -- - - - - -- S LEIN -------------------- ?ROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. ALL � THE NCYrE: ALL FEES MUST BE PAID PRIOR TO C_O. BEING ISSUED. NOTE: PLEASE BE ADVISED ALL PERMITS MUST BE INSPECTED. SCPA HyperLiteWeb Parcel View: 32 -19 -30 -507- 0000 -0090 C" d,lorx,ron.CfrA Parcel: 32-19-30-507-0000-0090 PR&ijt �' Owner: WRI SEMINOLE II LLC .APPRAISER Property Address: 1751 W P BALL & 1771 BLVD SANFORD, FL 32771 SE 1Y FLORK)A < Back Save Layout Reset Layout New Search Parcel: 32 -19 -30 -507- 0000 -0090 Value Summary Property Address: 1751 W P BALL & 1771 BLVD Owner: WRI SEMINOLE II LLC Mailing: PO BOX 3467 HOUSTON, TX 77253 Subdivision MARKETPLACE AT SEMINOLE TOWNE CENTER Name: REPLAT Tax District: Sl- SANFORD Exemptions: DOR Use Code: 1602 - RETAIL -POWER CENTER N X17 5 sR 7 41 r Map Aerial Both Footprint + R Extents Center Dual Map View - External Legal Description LOT 9 MARKETPLACE AT SEMINOLE TOWNE CENTER REPLAT PB 75 PGS 35 - 37 Tax Details Tax Amount without SOH: 2011 Tax Bill Amount Tax Estimator Save Our Homes Savings: ° Does NOT INCLUDE Non Ad Valorem Assessments 5423,320 5423.320 50 Taxing Authority 2012 Working 2011 Certified Taxable Valu Values Values Valuation S21,247,37 Schools Method Income Income Number of 521,247,375 SO Buildings 14 14 Depreciated S21,247,37 County Bonds Bldg Value s0 S21,247,37 Depreciated 3 MASONRY PILASTER. EXFT Value 25,043.00 CONCRETE TILT UP- MASONRY Land Value 51,379,393 (Market) MACrIAIDV DII ACTLR 7nnc 1 Land Value Ag rr)Alr'RFTr Tit T IID - MACr %IAV C1 rr:z 977 Just /Market Value 521,247,375 521,247,375 Portability Adj Save Our SO s0 Homes Adj Amendment 1 Adj so 50 Assessed Value 521,247,375 521,247,375 Tax Amount without SOH: 2011 Tax Bill Amount Tax Estimator Save Our Homes Savings: ° Does NOT INCLUDE Non Ad Valorem Assessments 5423,320 5423.320 50 Taxing Authority Assessment Value Exempt Values Taxable Valu County General Fund 521,247,375 s0 S21,247,37 Schools 521,247,375 50 521,247,37 City Sanford 521,247,375 SO 521,247,37 SJWM(Saint Johns Water Management) 521,247,375 s0 S21,247,37 County Bonds S21,247,375 s0 S21,247,37 Sales Deed Date Book Page Amount Vac /Imp Land Method Frontage Depth Units Unit Price Land Value ACREAGE 24.568 304,920.00 57,491,275 Building Information Page 1 of 2 L V` http:// www. sepafl. org/ ParcelDetails.aspx ?PID= 32 -19 -30 -507- 0000 -0090 11/14/2011 # Description Year Built Stories Total SF Ext Wall Adj Value Repl Value 1 MASONRY PILASTER. 2005 1 41,500.00 CONCRETE TILT UP - MASONRY 52,109,829 52,312,141 2 MASONRY PILASTER. 2005 1 12,080.00 CONCRETE TILT UP - MASONRY 5613,840 5672,701 3 MASONRY PILASTER. 2005 1 25,043.00 CONCRETE TILT UP- MASONRY 51,258,696 51,379,393 A MACrIAIDV DII ACTLR 7nnc 1 73 100 nn rr)Alr'RFTr Tit T IID - MACr %IAV C1 rr:z 977 C1 R77 n3R Page 1 of 2 L V` http:// www. sepafl. org/ ParcelDetails.aspx ?PID= 32 -19 -30 -507- 0000 -0090 11/14/2011 L SILENT 30 KNIGHT by Honeywell Model SD5OO -ARM Addressable Relay Module Place relay applications anywhere on the IntelliKnight loop with the SD500 -ARM Addressable Relay Module. The SD500 -ARM is an addressable device that adds great flexibility to the IntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500 -ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other IntelliKnight SLC devices, the SD500 -ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices —easy installation and stable operation —and it adds up to a flexible solution for all your fire protection needs. Model SD500 -ARM Addressable Relay Module The SD500 -ARM provides two Form C contacts rated at 2A @ 30 VDC or .6A @ 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the IntelliKnight panel. Features • Two sets of Form C contacts. • Contacts are rated at 2A @ 30 VDC or .6A @ 120 VAC. • Up to 127 relays can be used on each SLC loop. • Relay programming is completely flexible —can be mapped to zone conditions. • Polling LED visible through cover plate. Specifications Contact Rating: Form C Mounting 4- square electrical box Model S113500 -ARM Approvals • UL listed, complies with NFPA 72. • CSFM approved • MEA Approved, 429 -92 -E, Vol. 9 • FM approved Compatible Control Panels • 5820XL • 5808 • 5700 2A @ 30 VDC .6A @ 120 VAC Standby Current: .55 mA Alarm Current: .55 mA Ambient 32 °F to 120 °F Temperature (0 °C to 49 °C) Mounting 4- square electrical box Model S113500 -ARM Approvals • UL listed, complies with NFPA 72. • CSFM approved • MEA Approved, 429 -92 -E, Vol. 9 • FM approved Compatible Control Panels • 5820XL • 5808 • 5700 Model SD500 -ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500 -ARM. The modules shall be UL listed compatible with Silent Knight's Intelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4- square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW 4 -7/8" Model SD500 -ARM Addressable Relay Module Dimensions 1/4" SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT to keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350218 Rev. D b Honeywell subject to change without notice. For more information, contact Silent ©2010 Honeywell International Inc. y y Knight 12 Clintonville Road, Northford, CT 06472 -1610. Phone: (800) 328 -0103, Fax: (203) 484 -7118. www.silentknight.com Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert °Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug -in design with minimal intrusion into the back box Tamper- resistant construction Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela Field- selectable candela settings on ceiling units: 15,15/75, 30, 75, 95, 110, 115, 135, 150,177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL sync module Agency Listings SIGNALING 9 LISTED APPROVED 5401;:chims, horn mobss. horns) 3023572 5551: (mobe$) 715 - 1653:1:6 (nor. mobs. SPECTRAiert t �s'r::a'q•:,hi`SL'!.SXs t e'm'+Sa.°e: <n*?s`o. The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE- printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time - consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections. 9 MEA approved 7175-1653.1:6 fmdoor mobes) 715 - 1653:1:6 (nor. mobs. MEA452 -05 -E chore motes) 7135- 1653:1:9(horn %6i ) SPECTRAiert t �s'r::a'q•:,hi`SL'!.SXs t e'm'+Sa.°e: <n*?s`o. The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE- printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time - consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box, or double -gang back box.Two- wire products shall also mount to a single -gang 2 x 4 x 17 /s -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync - ircuit` Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync - Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24- volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95, 110, 115, 135, 150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens /reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non - temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11A6 x 477,8 x 21/8 -inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32T to 120T (0 °C to 49 °C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V 0 2 V nominal) or 16 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8- diameter x 25 -high (173 mm diameter x 64 mm high) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1- diameter x 2.2- high (180 mm diameter x 57 mm high) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC- HS,TRCW -HS) 6.9- diameter x 035 "high (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVD500500 UL Current Draw Data High Candela Range DC Input 135 150 177 185 8 -17.5 Volts 15 15/75 NA NA NA NA 16 -33 Volts 15 NA NA NA NA 15/75 30 75 8 -17.5 Volts 228 246 281 286 95 16 -33 Volts 207 220 251 258 115 Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range DC Input 135 150 177 185 8 -17.5 Volts 15 15/75 NA NA NA NA 16 -33 Volts 15 NA NA NA NA 15/75 30 75 228 246 281 286 95 110 207 220 251 258 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low e DC Input 132 16-33 Volts 135 150 154 177 80 185 90 105 FWR Input 161 184 16 -33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data 8 -17.5 Switch Volts Position Sound Pattern dB DC FWR 16 -33 Volts DC FWR 24 -Volt Nominal Reverberant DC FWR Anechoic DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 95 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 TSettings 7, 8, and 9 are not available on 2 -wire horn strobes AVJS0C500 SSpectrAlert Advance Dimensions a. 2.5' Ceiling -mount horn strobes SpectrAlert Advance Ordering Information ,. Ceilinq Horn Strobes PC2R' 2 -Wire Horn Strobe, Standard cd, Red Ceiling Strobes SCR Strobe, Standard cd, Red ° 225 Li Ceiling back box skirt PC2RH 2 -Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red PC2W" 2 -Wire Horn Strobe, Standard cd, White SCW` Strobe, Standard cd, White PC2WH` 2 -Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red Accessories PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White BBSC -2 Back Box Skirt, Ceiling, Red BBSCVd -2 Back Box Skirt, Ceiling, White TRC -HS Trim Ring, Ceiling, Red TRCkN -HS Trim Ring, Ceiling, White Notes: ' Add' -P'to model number for plain housing (no'FIRE' marking on cover), e.g., P2R -P. t Add' -SP"to model number for'FUEGO °marking on cover, e.g., P2R -SP. ?"Standard cd'refers to strobes that include 15,15175,30,75,95, 110, and 11S candela settinas.'Hioh cd'refers to strobes that include 135,150, 177, and 185 candela settings. Sl E/ P/ 01m mange .mn. �* 3825 Ohio Avenue • St. Charles, IL 60174 Product speC�n:auom su'J)ec[r manoe vnthou[noucc Van syscemsemorcom fa /lOJ�R` Phone: 800- SENSOR2•Fax: 630- 377 -6495 cunen; prnduainfomAVDS0 500.6/1 the .92;,�ersonothls data sheet nwsoosoo • en . - xlaos Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert6Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug -in design with minimal intrusion into the back box Tamper- resistant construction Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela Field- selectable candela settings on wall units: 15, 15/75,30, 75, 45, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices Compatible with MDL sync module Agency Listings SicxauHs 0 LISTED APPBDVM 5447' Irhimes,ho=b..homs) 30_:57_ 5551:. 1mob' ) 7125 -16531 BE (hom nmb.. SPECTRAlert The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections. 0 MEA approved 7125-1653 8' Odo M be, 7125 -16531 BE (hom nmb.. MEA452 -05 -E chime stmbs) 7135 - 1653189 (hom,, chimes) SPECTRAlert The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box or double -gang back box Two -wire products shall also mount to a single -gang 2 x 4 x 17 /a -inch back box A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync - Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync- Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a reaulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15, 15R5, 30, 75, 95, 110,115, 135, 150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens /reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non- temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync- Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4"/16 x 4'/16 x 21/8 -inch back boxThe module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. cat/Electrical Standard Operating Temperature 32 °F to 120T (0 °C to 49 °C) Humidity Range 10 to 93% non - condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range' 8 to 175 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6- L x 4.7 -W x 25- D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6 -L x 4.7 -W x 1.3- D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9 -L x 5.0 -W x 2.2 -D (151 mm L x 128 mm W x 56 mm D) Wall- MountTrim Rinq Dimensions (sold as a 5 pack) (TR -HS, TRW -HS) 5.7 "L x 4.8 -1N x 0.35- D (145 mm L x 122 mm W x 9 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AV7i 500600 UL Current Draw Data ��14iVF .S_7�- ��T7��Fni- lii�Clrl`? &f; it: \rtL'�I -7. 290 210 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 8 -17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non - temporal High 57 56 69 75 Non - temporal Medium 42 50 60 69 Non - temporal Low 41 44 50 50 115 NA NA 290 210 205 215 Coded High 57 55 69 75 High 135 NA NA 228 209 207 250 Coded Medium 44 51 56 69 Candela Range 150 NA NA 207 246 248 220 Non - Temporal High Coded Low 40 46 52 50 177 NA NA 275 281 Non - Temporal Medium 251 259 293 299 Non Temporal Medium 219 185 NA NA Non Temporal Low 286 254 258 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8 -17.5 16-33 8 -17.5 Volts 16 -33 Volts Switch Volts Volts Reverberant Anechoic DC Input 15 15/75 Position Sound Pattern 15 DC FWR 15175 30 75 95 110 115 Temporal High 137 147 High 79 84 84 90 107 176 194 212 218 Temporal Medium 132 Medium 144 80 80 69 86 80 97 157 182 201 210 Temporal Low 132 76 76 143 80 66 77 93 154 179 198 207 Non Temporal High 141 92 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 6 Non Temporal 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non - Temporal Low 132 154 80 90 105 161 184 202 211 e TV "'MRIM 16 -33 Volts 16 -33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non - Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8 -17.5 16-33 24 -Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 101 81 Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2 -wire horn strobes. AVD50:600 SpectrAlert Advance Dimensions Wall -mount horn strobes SpectrAlert Advance Ordering Information 5.05'=x{ �2.23'1 � 0 O C 5.98" EC O 0 9 9 Wall back box skirt Wall Horn Strobes Horns P2R *' 2 -Wire Horn Strobe, Standard coil, Red HR Horn, Red P2RH* 2 -Wire Horn Strobe, High cd, Red HW Horn, White P2W* 2 -Wire Horn Strobe, Standard cd, White Accessories P2WH* 2 -Wire Horn Strobe, High cd, White BBS -2 Back Box Skirt, Wall, Red P4R* 4 -Wire Horn Strobe, Standard cd, Red BBSW -2 Back Box Skirt, Wall, White P4RH 4 -Wire Horn Strobe, High cd, Red TR -HS Trim Ring, Wall, Red P4W 4 -Wire Horn Strobe, Standard cd, White TRW -HS Trim Ring, Wall White Wall Strobes SR *' Strobe, Standard cd, Red SRH *' Strobe, High cd, Red SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Notes: • Add " -P'to model number for plain housing (no'FIRE' marking on cover), e.g., P2R -P. t Add " -SP "to model number for "FUEGO'markina on cover, e.g., P2R -SP. '"Standard cd'refers to strobes that include 15,15/75,30,75,95, 110, and 115 candela settings. 'High cd* refers to strobes that include 135, 150, 177, and 185 candela settings CTELIIF 02011 Svslem Sensor ✓✓ ✓ / `/ 3825 Ohio Avenue • St. Charles, IL 60174 Prndua speanhumu subea[c chan?e wiffiow, nonce Vsn sv emsensormm fa SENSOR' Phone:800-SENSOR2 • Fax: 630-377 -6495 cunentprMuamfo nana , m600- 6111.92 w_rsmno'ffiuda;ash =n �,vasoosoo � 6/1 �, . azeo2 DN- 6933:B • E -205 BAT series Batteries N ®T 1 F1 E Rv Sealed Lead -Acid by Honeywell General Features • Provide secondary power for control panels. • Sealed and maintenance -free. • Overcharge protected. • Easy handling with leakproof construction. • Ruggedly constructed, high- impact case (ABS, polystyrene, or polypropylene, depending on models). • Long service life. • Compact design. Part Number Reference & Specifications 6933 -qpg Agency Listings and Approvals The listings and approvals below apply to BAT Series Batteries. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Recognized Components: MH2O845 (Power - Sonic) Current Part Number Power Sonic Part Number Battery Description DIMENSIONS Nominal Voltage V Nominal Capacity @ 20 hr. rate A.H. Width Depth Height Height over terminal Weight in. mm in. mm in. mm in. mm lb. kg. BAT -1250 PS -1250 12 5 sealed 3.54 90 2.76 70 4.02 102 4.21 107 4.1 1.9 BAT -1270 PS -1270 12 7 sealed 5.95 151 2.56 65 3.7 94 3.86 98 4.8 2.18 BAT -12120 PS -12120 12 12 sealed 5.95 151 3.86 98 3.7 94 3.94 100 7.92 3.59 BAT -12180 PS -12180 12 18 sealed 7.13 181 2.99 76 6.57 167 6.57 167 12.6 5.8 BAT -12260 PS -12260 12 26 sealed 6.56 167 6.97 177 4.92 125 4.92 125 17 7.71 BAT -12550 PS -12250 12 55 sealed 19.04 230 654 138 8.2 208 18.98 1228 136 16.33 BAT - 121000 PS- 121000 12 100 1 sealed 112 305 6.6 168 18.2 1208 18.98 1228 168 30.84 Bulk packs: Bulk packs are available for all models except BAT-12550 and BAT - 12000. • BAT-11 250-BP: 10 -unit bulk pack of BAT -1250 • BAT-12180-BP: 2 -unit bulk pack of BAT -12180 • BAT-1270-BP: 5 -unit bulk pack of BAT -1270 • BAT-12260-BP: 2 -unit bulk pack of BAT -12260 • BAT-1 2120-BP: 4 -unit bulk pack of BAT -12120 6.5 13 6.0 12 v rn -° 5.5 11 5.0 10 M 4.5 9 4.0 8 0 Characteristic Discharge Curves 120% 100% 80% Z' 60% .0 M Cm 40% 20% 1 2 3 5 10 2030 60 2 3 5 10 20 30 fminutes i hours Discharge Time @ 20 °C (68T) 0% -20° -10° 0° 10° 20° 30° 40° 50` 60° Temperature (Degrees C.) Effect of Temperature on Capacity 3 DN- 6933:6.01120/2011 - Page 1 of 2 100% 90% 0 ff 80% 70% at of 60% �U p- 50% U 40% 0% 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) 14.0 V 13.0 V rn 12.0 V 11.0 V 10.0 V H 9.0 V 8.0 V .Charging is NOT necessary unless 100 % of capacity is required. 5'C (41 °F) Charging before use is necessary to help recover ■ . . .. 100A 3 -■, full capacity. Charge may fail to restore full capacity. 40 °C 30 °C 20 °C (104 °F) (86 °F) (68 °F) DO NOT let batteries reach this state. 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) 14.0 V 13.0 V rn 12.0 V 11.0 V 10.0 V H 9.0 V 8.0 V 3 e 200A 1.2 2.4 6 12 24 36481 2 4 6 810 20 40' MINUTES x HOURS Discharge Time at left. PS- 121000 Shelf -Life and Storage 3 z at left. PS- 121000 Discharge Characteristics NOTIFIERO is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ' 0 0 0 We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. BIG11110INC & MMINTIB11Y6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 2 of 2 — DN- 6933:B • 01/20/2011 ■ . . .. 100A 3 -■, 1.2 2.4 6 12 24 36481 2 4 6 810 20 40' MINUTES x HOURS Discharge Time at left. PS- 121000 Shelf -Life and Storage 3 z at left. PS- 121000 Discharge Characteristics NOTIFIERO is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ' 0 0 0 We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. BIG11110INC & MMINTIB11Y6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 2 of 2 — DN- 6933:B • 01/20/2011 DTK=120HW/240HW1120/240HW Equipment Panel /Dedicated Circuit Akltl�j =1 J -;1911 *t -- d DITEK's "HIM' series of surge protectors are engineered and manufactured to the exacting standards of the life safety industry. More fire alarm panels worldwide are protected by the 120 HW than any other protector. The "HIM' series has a 15 year reputation for performance, reliability and quality. These units are the only real choice, for sensitive electronics on a dedicated circuit. FEATURES BENEFITS Diagnostic LED Indicates ground presence, unit function and power on Small footprint Can be used in wide array of applications Parallel connection Maintains power to system Three voltage configurations Works on all single phase applications ONE DITEK CENTER 1-800- 753 -2345 1720 Starkey Road, www.ditekcorp.com Largo, FL 33771 General Specifications - HW Series Continuous Current: Unlimited (parallel connection) Protection Modes: L - N, L - G, N - G Warranty: Ten Year Limited Warranty Dimension: 2.90" x 1.62" x 2.05" Weight: 0.18 Ibs Housing: ABS Other Specifications 120HW❑ 0 120/240HW❑ ❑ Agency Approvals:❑ ❑ 0 UL1449 /cULED N /A0 ❑ Connection:® 0 ❑ ❑ 110- 120VACiD 120 /240VACm MCOV: ❑ ❑ 0 ❑ ❑ 130VAC ❑ ❑ 130/260VAC m Max Surge Current:❑ ❑ ❑ 22,500A0 ❑ 27,000AD ❑ UL Suppressed Voltage Rating:® 500V00 ❑ N /AO 0 0 112, IQPT :;0NDUIT - 3X 44.,1 _ 1 _..__.. _ n '- l 2! aLO'r . 5" X . 18' PZ.forWi N/A 220- 240VAC 250VAC 13,500A N/A 1,45" t 2_G5 t' 1 rr'