HomeMy WebLinkAbout373 Gordon St 12-632(a)C,
I
TO
UD
0
N
0
N
N
N
\
N
m
O
w
a
un
o0
N
Y
ff3
a
L
c
c
00
O
w
ro
a�
M
U)
,--1
T--1
cii
1,
------------------------- - - - - -- 1
I I
ISUivi tTRIC
Scale: NTS
I i
2 AWNINGS
i ' I Scale: NTS
WOOD STUD OR
WOOD BLOCKING
�-STEEL " x 1 Y2' WIDE I Y2' WIDE a : BRACKET
BRACKET
u J-4
x 3' LAG BOLT d EMBED 2' G 3/8' x 1 W SLEEVE ANCHOR,
MIN EMBED 1 Ys',
MASONARY WALL
VE I WALL LINE
MEMBER V FRAME MEMBER
Y2- H1DE 2 #IOx -' TEK
SCREW
BRACKET
K' x 1 Jz' WIDE
STEEL BRACKET
FASTENER
E SEE ABOVE
DETAIL
TEK ON THE SIDE
DETAIL
TEK UNDERNEATH
WALL ATTACHMENT
SIDE VIEW
1"
4 _0»
L
7-0" AFF
�1� Minimum Clear
v-
4' -0"
nnnnnr-rn A 111AIIAInf"
6 ELEVATION
Scale: NTS
J5' x 1 12' WIDE
STEEL BRACKET
r r
r r
/14x4' TEK SCREW
r r
r r STEEL SLEEVE FOR
r SPACING
DRYNT WALL
SYSTEM
"—STANDARD METAL
STUD
DRYVIT WALL SYSTEM
STOREFRONT OR
METAL STUD
—1¢' x 1 Yz' VADE
STEEL BRACKET
x 314' TEK SCREW
MUWON
"—WINDOW GLASS
ALUMINUM STOREFRONT
O O
0
0 0 0 0
O
UNDER FRAME ABOVE FRAME SIDE OF FRAME
Mounting Option Mounting Option Mounting Option
Note:
Job Name:
exceed the 110 mph, 3 second gust,
AERO 8 INDUSTRIAL PARK
All framing is made of 1 "Sq tube Aluminum
Type of Cover:
1/8" wall.
Job Number:
12856 -07MS
All aluminum to be 6061 -T6
Cover color:
All connections are welded.
Frame Qty.:
7 FRAMES
All fabric is fire retardant.
Valance:
See attached certification.
FrameSSize:
Wind Speed of 110 mph.
Frame Material:
Aluminum
Exposure category C
Frame Finish:
Importance Factor 1.0
Mill Finish
Internal Pressure N/A
Finish Color:
Wind Pressure +/- 33 psf.
Binding:
NOTE:
Underside Color:
Note:
This certifies that these plans meet or
Sides:
exceed the 110 mph, 3 second gust,
CLOSED
wind load requirements of Chapter #16
Type of Cover:
2007 Edition of the Florida building
PATIO 500
code with 2009 supplements.
Cover color:
HUNTER GREEN
BRYAN A. MOLYET P.E.
Valance:
1060 East Industrial Dr, Ste, W
411
Orange City, FL 32763
Valance Type
(386) 532 8000
WRAP
Reg. Fla. Engineer No. 041509
Applique: I
Florida Certificate of Authorization No.00009855
Binding:
NOTE:
These structures have been designed so that the fabric will
Graphic:
break away during periods of time as designated by the
�h
I
U.S. Weather Bureau as being a Hurricane warning or alert
in accordance with Section 3105.4.2.1
Lace bar: Al Al Y
of the 2007 Florida Bldg. Code.
SCALE
12856 -10MS AS NOTED
DATE WHAF151Ak
12/22/11 rp
yam, C?EOD BY
1 1 mn
AERO 8
Industrial Park
373 Gordon St. `� AWNING
Sanford, FL 32771 50 Keyes Court n,rltin �ra/Afwr�L7mvas sor eou,
Sanford, FL 32773
Canopy Drawings I An7 non l— _ —7 - 1177 f-