HomeMy WebLinkAbout1500 W Airport Blvd 12-888 bldg 16 heat detectorj_<. CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No:'— (� Documented Construction Value: $ x,227 • �� Job Address: 1500 Uri Parcel ID: 0 Z - Z 0-30 -3( Description of Work: Plan Review Contact Person: Phone: 40-V—T_ 4 -&Poo N1KPO K`r &01 - E)LX [ (p Historic District: Yes ❑ No ❑ �) - 03 60- o 000 Zoning: MPAK, Title: CAL rr4WIkC�$� Fax: ,Jbj --774 - Z074 E -mail: C" i S-k- kz n1 SaJ 0 Property Owner Information —q1<t C0;SCGs . c.oM, Name K H "V AN L&n1 ATOEd ,UW-ho u %TLC Phone: Street: l fioo 5 f%STMLLAA A�Ii; STE4400 Resident of property? City, State Zip: W S- I-RALM g,EqQ� T-L SSi- cR -645o Contractor Information Name �1R� T P,anS(CS (� Phone: 40- 1-'Z'7`(-(dR00 Street: X035 PinSt RoUDW QawTjr_, Fax: 4:0'1-"174c - Zo74 City, State Zip: NL'WMdWrE�_ aKit4GS 3V State License No.: EF6000423 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: PERMIT INFORMATION Building Permit ❑ Square Footage: No. of Dwelling Units: Electrical ❑ New Service - No. of AMPS: Construction Type: Flood Zone: Mechanical ❑ (Duct layout required for new systems) Plumbing ❑ No. of Stories: New Construction - No. of Fixtures: Fire Sprinkler /Alarm 12"'No. of heads: 1- �O'r Too•d IV101 12/15/2011 17:38 407x742074 I FIRETRONICS PAGE 01/01 FWT_R`0_1N1CS,1N1C, ONICS, INC. - DAYTONA - FTRI T TING* . 14 3 Pine 11-61 low ,Point Dlr, A1>> momalSprcng5<rYL, 32? 14 . �h�nl�_ �6 � ��� -6904 / fkt:. 407'-7',,74 -2b74 " ±�y� PROPOSAL SUBMITTED TQ r r lT 'fry Tod Name; PINE RIDGE CONDOS Addrass :..1500 W. hIRPQJtT BLVD- Address: City, St, Zip: SANFORD, FL. 32773 1F� Iu; a ji Date: 12-15-11 2� Plione: 407- 682- 3443/I?AX 407- 882 -01$1 Contact: SHAWN Job Namo: PINE RIDGE CONDOS we hereby submit specifscations and estimates for: PD4F RLDCTE CONDOS PAIRS (SERVICE) ESTIMATE IS rOR THE FOLLOWING REP t6 TO THE FMB ALARM SYSTEM AT TEE ABOVE RL'FERENCLD PROPERTY, 1, BUILDING 916: I , SUPPLY AND INSTALL AND TEST (1) F ALA.kM CONTROL PANEL (Sx2). 2. SUl?,PLY AND LNSTAT L (2)�JTW }3p,,T'pFR,� 3. HEAT DOCTOR. 4. FFI iVIT AND URAWJNG F} FS S. UBOR TT J TQTAT, PRICE FOR THE ABOVE WILL"ar, 5,1+,22 (5.74 + HOURI.`Y L�AAtPI�, O FNAL INSPECTZ0 + TAX. NOU �> 1. TIiIS QUOTED OES NOT IrLTDEb ,ANi? OTITER UPGRADES OTHER TRAM LX$TriD ABOVD. 2. THIS QUOTE DOTS NOT INCIUDE ANY PlArilN 0 OR PATCIEZYG, ETA' TiEQUzREA. We hereby proposeto famish labornnd materials compiele in Recordancc with the nbavo (Dollnr;)($) payment to be made Ai follows: NU 15 DAYS U r aN COMPLETION This pmpml does not inc[Ude 120V hockvp or the necess�ty conduit to install tho above dcviccx All materlat is guaranteed to be nq specified. 11 work to b4 completcd in a workmanlike manna ataordh1 tp MAATO pl;1ct10C9, Any alteration or deviation from above involving extra cos}g. witt tic =c=cd;ronly Upon written order, and wiH beeom0 an extra charge over And ahovo the c rimate. WP mvira one set of specilicltions Ind Dnludnp9. ' All flaMments contingent "Pon strikes, aeeid,,:ntq ar detmyg h4YOTd our conprl, Wa will provide a ono- yegr- arrtnty covering materiels Zack Mbar, cociudmg- -;Acts oa ' nakirca�fite, th l}; wndaiiArat, ar tompeiing by unaurho %ed personnel. Any l CV1f= incurred due tanoh_ paymct?toFconcricNw,tllscypurrc pngrh,t�ty p s" If a job rc4airts n bond, add 2% to iontm t Pd 6c':' i ! I WA proposal suhicct to ncccptnncc FQ8 $ 2% -Rance charec FircMnim Atitdmr!7cd Signature; days and iy void. thcmfter atthe npdoh of the aederai�ncd. MARTY COLLIER, VICE PRE$l4F1'r AC"PTX4CS OF PROPOSAL the above priccn, s7aceiliendarm And eondido"s are tweby aeeapted. You arc aathorimed to do the work A_. apa6f Cd. P1yl'nant will be retde ns outlined Above. DATE ACCEPTED: } Custpmar Sigmrturc FIRE ALARMS, EXTINGC!1SH RSk' HY' DRANTS, SPRINKLERS, SACKFLOW, SPECIAL. HAZARDS, RESTAURAN,rHOOD :SYSTEMS, BURGLARY, ACCESS CONTROL & CCTV State License Fire # EF0000423 ^ Contractor 1 # 60746800012004 ' Contractor 2 # 63490100012005 Class A # 510942000120004 " Class 6 # 685827000195 '* Class D # 70145200012005 FIRIETRONICS, INC. � FI I ETRO I , INC. - DAY T'O A FIRETRONI S EXTINGUISHERS!, I TC. 1035 Pine [-follow Point Dr. A ta- nionte Springs, FL. 3 714 - phone: 407 -774 -6900 / fax: 407 - 774 -2074 LIMITED POWER OF ATTORNEY Date: I herby name '0�'X to be my lawful attorney in fact to act for me and submit/ receive the Fire Alarm /Burglar Alarm permits for work to be performed at the described location: ISM�� ' �l (Address of Job) (Owner of Property) I� Parcel ID number And to sign my name and do all things necessary to this appointment: (Signature of Certified Contractor)) Robert W. Parris #EF0000423 (Printed Name of Contractor and License Number) Witness 2 STATE OF FLORIDA COUNTY OF: Seminole The foregoing instrument was acknowledged before me this 1 `5 "�" day of 201jr by RjobeTtV. Parris, who is Q personally know to me or has ❑ produced (type of id tification). 4, oiSY.Y Pj-" Notary Public state of Florida Vicky Spinella 1 Il V N, o My Commission 0 D768858 r Expires 05/14i2012 Signature of otary Public, State of Florida 7,(SEAL) . nc Type/ Stamp Name of Notary Public FIRETRONICS, INC. I' FIRETRGNICS EXTINGUISHERS, INC. 1035 PINE HOLLOW POINT DR. ALTAMONTE SPRINGS, FL. 32714 PHONE (407) 774 -6900 * FAX (407) 774 -2074 FIRE ALARM SUBMITTAL FOR PINE RIDGE CONDOS 1500 W AIRPORT BLVD BUILDING # 16 CITY OF SANFORD STAND ALONE FIRE ALARMS, EXTINGUISHERS, HYDRANTS, SPRINKLERS, BACKFLOW, SPECIAL HAZARDS, RESTAURANT HOOD SYSTEMS, BURGLARY, ACCESS CONTROL & CCTV State License Fire # EF0000423 * Contractor 1 # 50746800012004 * Contractor 2 # 63490100012005 Class A # 51094200012004 * Class B # 68562700011995 * Class D # 70145200012006 SILENT KNIGHT by Honeywell SK -2 & SK -2E Fire Alarm Control Panel A flexible, powerful, cost - effective panel for fire protection applications. The SK -2 and SK -2E (SK -2 /E) are two zone conventional fire alarm control panels (FACPs) that bring the latest in microprocessor technology to conventional fire controls. The SK -2 is a 120 VAC FACP and the SK -2E is a 240 VAC FACP. These FACPs provide reliable fire signaling protection for small- to medium -sized commercial, industrial, and institutional buildings. For more information about the SK -2 /E system, or to locate your nearest source, please call 1- 800 - 328 -0103. Description The two zone SK -2 /E is a 24 VDC FACP that provides two Class B initiating device circuits and one Class B notification appliance circuit (NAC). The SK -2 /E NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires. The SK -2 /E is also compatible with conventional input devices such as two- and four -wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally -open contact devices. Activation of a compatible smoke detector or any normally -open fire alarm initiating device activates audible and visual signaling devices, illuminates an indicating LED, sounds the piezo sounder at the FACP, activates the FACP alarm relay, and operates an optional module used to notify a remote station or initiate an auxiliary control function. The SK -2 /E is compatible with System Sensor° 13 detectors providing advanced features such as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio /visual devices is provided, using three selections for manufacturer protocol. Features • Two Style B (Class B) initiating device circuits (IDCs) • One Style Y (Class B) notification appliance circuit (NAC) • Support for synchronization of standard ANSI audible signals and ADA compliant strobes per NFPA 72 • Selectable for System Sensor, Wheelock, and Gentex protocols • Selective silence feature allows manual silence of horns while strobes continue to flash on the same NAC • Silent or audible walk test operation mode • Alarm verification selectable per zone • Program each zone for supervisory or fire with separate red and yellow LEDs • Disable switches provided per zone • Program NACS for — Silence inhibit —Auto silence — Strobe synchronization — Temporal or steady signal — Silenceable or nonsilenceable — Disable • Form C alarm and trouble relays • 3A total usable current • Optional dress panel (PN SK- DP2 /4) Electrical Specifications SK -2 Primary AC: 120 VAC @ 50/60 Hz, 2.3A SK -2E Primary AC: 240 VAC @ 50 Hz, 1.15A Wiring: 14 AWG (2.0 mmz) with 600 V insulation min Initiating Device Circuits (IDCs) Operating Voltage: 22 VDC nominal; power - limited Standby Current: 4 mA _ Alarm Current: 15 mA min Short- circuit Current: 40 mA max Loop Resistance: 100 max EOL Resistor: 4.71K . 1/2 watt SK-2 NACs 2.5A @ 24 VDC with standard transformer, power - limited Signaling Current: 2.5A max with standard transformer EOL Resistor: 4.7K , 1/2 watt Form C Relays Types: Trouble and alarm Contact Ratings: 2A @ 30 VAC, resistive Auxiliary Output Resettable Operating Voltage: 24 VDC nominal Current: 500 mA max, power - limited t= 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a low -cost means for property protection against fire, and for non -life- safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: — Single- and dual- circuit models — Fixed temp and combination fixed- temp /rate -of -rise 135 °F or 194 °F ratings. Plain housing for residential installations (Model 5601 P) Easy -to -use terminal screws A broad range of back box mounting options: Single gang — 3.5" and 4" Octagonal —4 "square with square to round plaster ring Reversible mounting bracket Agency Listings (@ <j�> MEA O. LISTED APPHOVEn approved `" $2101 :3016 119 I9,103-E 7270- 1209227 s 1 Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual- circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature/rate -of -rise (ROR) activation.The ROR element of the fixed /ROR models is restorable to accommodate field- testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four - square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both Flush -and surface-mount back box. installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed /rate -of -rise units are marked FX/ROR.The 5600 series also provides a post- activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. L h-C 12t cg � c S L � s �,e L � � \°a.. b U.�� Pi1'f, er - T.imiti -d /Unchinldnrl DESCRIPTION Plerrecom II1'-y Extra Flexible FPLF • ASTM bare copper Polymer alloy insulation • Twisted pair or cabled construction n • Polyester binders as required • Flexible plenum jacket RATING • UL listed NEC type FPLP • Constructed in accordance with UL Standard 1424 • Complies with UL 910 test modified ASTM Steiner Tunnel Test • Meets 300 volt requirement as specified in Section 760 of the NEC APPLICATIONS Indoor (non - conduit per NEC) within ducts, plenums, and other spaces used for environmental air for: • Audio circuits • Control circuits • Initiating circuits • Notification circuits SPECIAL NOTES • Capacitance of unshielded cable may vary depending on the installation environment. • INSTALLATION PRECAUTIONS for plenum cable: refer to the Technical Reference Section 54 - - WEST PENN WIRE /CDT Standard spool size 1000 feet 'Capacitance between conductors. COLOR CODE r 1. Black, 2. Red, 3. Brown, 4. Blue JACHT: Red inch mm inch mm inch mm pf /ft' pf /m' 6O980B 1 18 Solid .010 .25 .015 .38 .142 3.61 29 95 Pair 6.5 ON 6O982B 4 18 Solid .010 .25 .015 .38 .175 4.45 29 95 6.5 QX 6099113 1 16 Solid .010 .25 .015 .38 .161 4.09 32 105 Pair 4.1 Q /M' 601646 4 16 Solid .010 .25 .015 .38 .220 5.59 32 105 4.1 WM' 609936 1 14 Solid .012 .30 .015 .38 .191 4.86 35 115 Pair 2.6 UN 607O0B 4 14 Solid .012 .30 .015 .38 .252 6.40 35 115 2.6 S2/M' 60995B 1 12 Solid .012 .30 .015 .38 .225 5.72 45 148 Pair 1.8 QX Standard spool size 1000 feet 'Capacitance between conductors. COLOR CODE r 1. Black, 2. Red, 3. Brown, 4. Blue JACHT: Red .O �o BE fal aw • AREA OF WORK BUILDING 16 KEY PLAN OUT`. BUIL OU- BUI BUILDING 16 EXISTING LECTR I CAL ROOM RISER DIAGRAM H SK2 SCOPE OF WORK: DEMO AND REPLACE FACP ADD 1-HEAT DETECTOR N OTE: ALL EXISTING DEVICES COMPATIBLE WITH NEW FACP SYMBOL MODEL DESCRIPTION NOTES SILENT KNIGHT FIRE ALARM DEMO AND SK2 FACP REPLACE Fi SYSTEM SENSOR FIRE ALARM INSTALL ABOVE FACP 5601 HEAT DETECTOR NOTES: 1 —THIS APPLICATION IS FOR THE INSTALLATION OF VARIOUS FIRE ALARM DEVICES. 2 —ALL WIRING SHALL BE IN ACCORDANCE WITH ARTICLE 760 OF THE N.E.C. 3 —THIS DRAWING IS DESIGNED IN ACCORDANCE WITH N.F.P.A. 72, 2002 EDITION. 4— MAXIMUM CONDUIT FILL IS 40%. S —WHERE APPLICABLE, AUDIOVISUAL DEVICES WILL BE SYNCHRONIZED PER N.F.P.A. 72 — CH.4- 4.4.2.3. PINE RIDGE CONDOS 1500 W AIRPORT BLVD NOT TO SCALE MARK STEPHENSON _ BUILDING 16 « „�. FIRETRONICS EF000s 774 -6900 FIRE ALARM ADDITION -1 OF 1