Loading...
HomeMy WebLinkAbout2650 Mellonville Ave 08-1584 (2)CITY OF SANFORD PERMIT APPLICATION Application #: U l I Submittal Date: 5 ", %- O Job Address: ZGSO S• Mgt 109 Ili Af- AIV ��'ard FL, a 17 73 Value of Work: $ 4200 - Parcel ID: 00 • ZO. 31. 3CO- 001 O - g540 Zoning: P-T - I Historic District: Description of Work: 6EPA9616#4 64 flAe XL4wiASc{.SfEtM IT> r}Bn> C gAkt4&W% Square Footage: Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler /Alarm Pool ❑ Sign ❑ Electrical: New Service — # of AMPS Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑ Mechanical: Residential ❑ Non - Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair— Residential ❑ Commercial ❑ Occupancy Type: Residential ❑ Commercial ❑ IndustrialaT Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required ) .......................... 1................................................................. ............................... Property Owner: ��7Gt11�0YO Q1�7of E Q.�t- ib101LoM Contractor: 4I &4 sec" L "J Address:12ZO CAay 6AA ?AA)a Address:3D1S T20T51+., L 3z 3 O F'L 32-Sr10 P une 5�5 4.Ot0 E- mail:AGl�t.JS t� IDS$.ZL- n(?::L Ph n�� State License Number: CF00000% Bonding Company: N" Mortgage Lender: Address: Architect/Engineer: Address: Plan Review Contact Person: Address: Phone: Fax: Phone: Fax: E -mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR- PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property yof the requirements of Florida Lien Law, FS 713. 05.08 -0g tia •may B�t�� s'-7.0s, Signature of Owner /Agent Date Sign re of Contractor /Agent Date ,%ZPreSi*e Adm►�;stro ;>►n�cx c �• remi t �c: i t Owner /Age t' N e Print Contractor /Agent's Name S �l0 _G Qir � ,y' 7 -4 �s Signature o otary-State of a Date Signature of Notary-State of Florida Date DIANA M. MUNIZ -OLSON MY COMMISSION #DD477605 , F MARIE E. KD EXPIRES: OCT 02, 2009 MY COMMISSION EXPIRES: Dearn Bonded through 1st State Insur ce n Nary D; wria _ ersonally Known to Me or Contractor /Agent is' finally, Kna Produced ID ProducedID APPROVALS: ZONING: UTIL: FD: ENG: BLDG: Special Conditions: Rev 07.07 FILE No.763 05 /08 '08 14 :32 ID:ORLANDO SANFORD AIRPORT FAX :407322 kE��E® PAGE 2/ 2 MAY 0 9 2008 CITY Of 5ANF4R16 PERMITAPPLICATIQN Appileatinn # : y - Submittal Date: -Job Address 24-FJ�4 44e lo ( �, �•7 7 Value of Work• Parcel 10; ,CNa 2A• !• Old „� s f5tk Zoning: Historic District: Description of Work: &FQs16,i A4 s' ,r A ........................ li .� t � :.' fie—t?$ ..................... ........... 'C�k�t► Square Footage: ............................................. - � Permit Type: Building ❑ F,lectrical 4 Mechanical ❑ Plumbing Q Fire Srinklar /Alarm .p N leetrical; New Scrviee - # of AMPS . , _ Addition /Alteration 91”' ool 1 :1 P Pool q Sign 4 Change of Service 13 Temporary Pole n Mechanical: Residential M Non•Residcntial E3 Replacement M New Q (Uncl i.ayout & Energy Calo. Required) Plumbing/ New commercial: # of Fixtures — — # of Water , Sewer Lines_ # of Gas Lines Plumbing/IVewResidential: #of Water Closets_ _ 0ceupancy'l'ype; Residential ❑ Commercial Q Industrial.T Plumbing Repair- Residential ❑ Commercial 0 Occupancy Use Group(s): Cunstruction '1'ypr: _ # of Stories; — _ # of Dwelling Units-, Flood Zo na: _ (PEMA torm required ) ...... .. Property Owncr: .....�� ��� ........ .... ..... .. C: t��( C ontrractoractor Address: Q -- _ Address, P ne: E- mail: / » � � f3.. — Bonding Company: �� ne • State License Numhcr: E�OppCatS� Mortgage Lender:— 04 VA Address: Address: Architect /E,agincer: 11 - Address; Phone:, ��. Plan Review contact person: Fax: Phone: �. Fax: . E-mail. APPlicalion is heieby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performad to meet. standards of all laws regulating construction in this jurisdiction. I understand that a ,eparate permit mLLSt be secured for FLGC fRICAL WORK, PLUMBING, SIGNS, WEI.I.S, POOLS, I'URNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AfFIDAV41I: I Certify that all of the toreguing information is accurate and that all work will he done in compliance wish all applicahlu laws regulating construction and zoning. WARNING TU ()VNLR: YOUR FAILURF: •1'0 RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR- PAYING; TWICE FOR IMPROVI;MF.N'I'S 'l'O YOUR PROPERTY. A NOTICE OP COMMENCEMENT MUST BE RFCORDED AND POSTED ON rI -IF 108 Sr1,L BFFORf_ TI-IL FIRST INSPECTION. IF YOU INTEND '1'O 0131 -AIN FfNANCING, CONSULT MTH YOUR I.FNIaER OR AN ATTORNEY 13FFORfi RECORDING Yatiie NO41Ck Of: COMMENCEMENT NO'i'1f�:1: la addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, anld (here may be additional permits required from other governmental entities such as water management districts, state agencies, or lledeml agencies. ice of permit is veriflcatlon that I will IlDti1'y the owner of rile property of the requirements of Florida Lien ).aw, FS 713. Signat„reofnwner /Agen1D� �•Q Rate Si 'n Die of Contractor /Agent Dale a 01ANA M. MUNIZ -OLSON MY COMMISSION #DD477665 &FIRES: 00T O2, 2009 Bonded through 1 at State Ins„ genet Produced ID -- APPROVALS: 70N1N(,: Special Conditions: Rev 07.07 Print Contractor /Agent's Name 't Date Signature of NolSry -Store of Plarnda pate 9'''~' MARE E. KUSHNER MY C%, M $$ION Y PD736474 `t, EXPIRES: Docanbor 10, 2011 Known to Me or Contractor /Agentisi NowyDt,wu "`A, .Ca. ,R f, owy, cote • � Produced iD UTIL: FD: _ LNG: 1`�11� A CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407 - 302 -2516 - FAX # 407 - 302 -2526 DATE: =V6/ ° g BUSINESS NAME/ PROJECT: A//// ADDRESS:d(C7�;) <�• PHONE NO.: FAX NO.: PERMIT #: CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEWZW F. A. [ ] F.S. [ ] HOOD ] PAINT BOOTH [ ] BURN PERM [ ] TENT PERMIT f ] TANK PERMIT [ ] OTHER [ ] TOTAL FEES; $ 7c o'D T (PER UNIT SEE BELOW) COMMENTS: Address / Me. ,# / Unit. # 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. SQuare Footage Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, Fl. 32771 Phone # -407- 330 -5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that 1 will comply with all applicable codes and ordinances of the City of Sanford, Florida. Sanford F' reventio ivision Applicant's Signature IntelliKnight® 5808 Single it Loop Addressable Fire Alarm 'k Control System The convenience of an addressable fire alarm control panel in a cost - effective easy to use package. IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control /communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763 - 493 -6435. Description 5808 performs drift compensation and calibration checks on each of the sensors in the system. The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial /parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5808 also features a powerful built -in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Up to 127 addressable points • Up to 125 zones and 125 output groups • Uses standard wire —no shielded or twisted pair required • Built -in digital communicator • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Distributed, intelligent power • Drift compensation • 13 pre - programmed output cadences, (including ANSI - 3.41), and 4 programmable outputs • Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built -in annunciator with 80- character LCD display • RS -485 bus provides communication to system accessories • Built -in RS -232 and USB interface for programming via a PC • Upload or download programming, event history, or detector status via remote or direct connection • Improvements in SKSS deliver five times faster upload /downloads • Built -in synchronization for appliances from AMSECO, Gentex@, Faraday, System Sensor@, and Wheelock@ • One Form C trouble relay rated at 2.5A at 27.4 VDC and two.Form C programmable relays rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time • Plex -2 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Electrical Specifications Primary AC: 120 VRMS at 50/60 Hz, 2.75A Total Accessory Load: 6A @ 27.4 VDC Notification Power: 6A @ 27.4 VDC, power - limited Standby Current: 170 mA Alarm Current: 325 mA Notification & Auxiliary Circuits: 3A @ 27.4 VDC per circuit, power - limited Battery Charging Capacity: 7.0 -35.0 AH Battery Size: 18 AH max. allowed in FACR Larger capacity batteries can be housed in an RBB accessory cabinet Mechanical Specifications Flush Mount Dimensions: 14.5 "Wx24.75 "Hx3.5'D (36.8 W x 62.9 H x 8.73 D cm) Overall Dimensions: 16" W x 26.4" H x 4.65" D (40.6 W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color- Red Telephone Requirements: Model 5808 FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non- coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559:142; MEA 429 -92 -E Vol. XIV SILENT KNIGHT by Honeywell SLC Detectors SD505 -APS Addressable photoelectric smoke detector. SD505 -AIS Addressable ionization smoke detector. SD505 -AHS Absolute temperature heat detector that goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range from 135 °F - 150 °F(0 °C- 37 °C). SD505 -6AB Six inch base for use with detector heads SD505 -APS, SD505 -AIS and SD505 -AHS. SD505 -4AB Four inch base for use with detector heads SD505 -APS, SD505 -AIS, and SD505 -AHS. SD505 -6SB Six -inch sounder base for use with existing sensor and base. Operates in single and multi- station modes and /or as a system sounder. Requires 2 additional wires for power. SD505 -61B Short circuit isolator base for SD505 -APS, SD505 -AIS, and SD505 -AHS detectors. SD505 -6RB Six -inch relay base for use with existing sensor and base. Provides one Form C contact. SD505 -ADH Duct housing that detects smoke in HVAC ducts. SD505 -ADHR Duct detector base with relay. Provides Form C alarm contact. For use with SD505 -APS and SD505 -AIS sensors. Compatible with SD505 -DTS remote test switch. SD500- PS /SD500 -PSDA SD500 -PS is a single action pull station and SD500 -PSDA is a dual action pull station. SLC Modules Model SD500 -AIM Dry contact input module for use with normally open dry contacts. It features an indicator LED to show alarm status. SD500 -MIM Mini dry contact input module is a small version of the SD500 -AIM. For use with pull stations and other normally open dry contact inputs. SD500 -ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. SD500 -ARM Addressable relay module that features two Form C output relays. Provides indicator LED to show output status. SD500 -SDM Two -wire detector input module. Allows for the connection of conventional 2 -wire detectors on the SLC loop. Requires two additional wires for power. SD500 -LIM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protected by the isolator module continue to operate. SD500 -LED An LED driver capable of driving 80 LEDs through the SLC loop. Up to 40 SD500 -LEDs can be used per system. S -BUS Accessories 5860 /11 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5808. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power - limited notification appliance circuit outputs. 5880 LED /10 Module Features 40 LED outputs, 8 normally I open dry contact inputs } and one piezo output. 5865 -3 and 5865 -4 Remote LED 4 Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865 -4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial /Parallel Printer Interface Module Provides one parallel and one RS -232 serial port for connecting a printer to 5808. Use to print a real -time log of system events, detector status reports, and event history. Miscellaneous Accessories 5660 Silent Knight Software Suite PC -base software for FACP programming. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End -user facility management software allows viewing of detector status and event history via modem or direct connection. Plex -2 Door Dead front cabinet door with clear window to limit access to the FACP. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SD505 -DTS Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505 -ADHR. SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are by Honeywell subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Phone: (800) 328 -0103, Fax: (763) 493 -6475. IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight MADE IN AMERICA FORM# 350386 Rev. D 04/06 Copyright © 2006 Silent Knight SD500 -PS and SD500 -PSDA Addressable Pull- Station IntelliKnight's addressable pull stations combine fast response with pin -point location ID. The SD500 -PS and SD500 -PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500 -PS /PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500 -PS /PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500 -PS & • Extremely easy to operate SD500 -PSDA Addressable Pull Station The SD500 -PS is a single action addressable fire pull station, and the SD500 - -PSDA is a dual action addressable fire pull station. The SD500 -PS /PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an IntelliKnight control panel. The SD500 -PS /PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold - plated to avoid risk of corrosion. The SD500- PS /PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features • UL Listed • CSFM listed • ADA compliant • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available • Terminals - accept up to 14 gauge wire Corrosion - resistant gold - plated contacts. Reflective label makes it easier to locate in low light Operation The SD500 -PS /PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500 -PS /PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby Current: .55mA Alarm Current: .55mA SD500 -PS Ambient Temperature: 32 °F to 120 °F (0 °C to 49 °C) Mounting: Single gang box - Optional Red Surface Mount Box PS -SMBB SILENT KNIGHT SD500 -PS and SD500 -PSDA I Addressable Pull- Station Engineering Specifications Manual pull station shall be addressable Module SD500- PS /SD500 -PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. Mounting to Single Gang Electrical Box E=`ti` Cs J f ,ti C3 i e On, Mounting to Optional Surface Mount Box SILENT KNIGHT Atri', uwrc4 Csari.' -sd 7550 Meridian Circle, Maple Grove, MN 55369 -4927 800 - 446 -6444 or in Minnesota 763 - 493 -6435 FAX: 763 - 493 -6475 World Wide Web: http: / /www.silentknight.com Wiring 3 Mal 6.1116* t ft"Idioof Dox most I" Dimensions attvvg 1- 02,0' -p MADE IN AMERICA FORM# 350342, Rev. 09/03 Copyright © 2003 Silent Knight Addressable Heat Detector IntelliKnight® addressable heat detectors combine accurate heat detection with pin -point location ID. An essential combination for any installation. IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505 -AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -AHS Addressable Heat Detector The SD505 -AHS is a heat detector suited to virtually any commercial setting. The SD505 -AHS is an absolute temperature device. This means that it responds in alarm if the temperature goes above the trip point (programmed at the panel). The SD505 -AHS provides accurate temperature measurement data to the fire alarm control panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes, such as in a kitchen. Operation The SD505 -AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits a signal representing the temperature to the IntelliKnight panel. If the temperature exceeds the trip point (programmed at the panel), an alarm occurs. The status LED lights continuously during the alarm period. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. Features • Low profile, 2 inches, including base • Absolute temperature device • Simple and reliable addressing • Uses digital communication protocol • The SD505 -AHS is UL Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. • CFSM listed • MEA listed • FM approved SILENT KNIGHT by Honeywell SD505 -AHS Heat Detector Specifications Operating Voltage: 17 to 41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135 °F to 150 °F (57 °C TO 65 °C) Ambient Temperature: 322F to 1202F (02C to 492C) Mounting: 4" SQR, 4" OCT Single gang mud ring Rated Spacing: 70' between sensors on smooth ceilings. Compatible Bases: SD505 -6AB (Sold Separately) (6" Base) SD505 -4AB (4" Base) Model SD505 -AHS I I Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505 -AHS. The combination detector head, and twist -lock base, shall be UL@ listed compatible with Silent Knight's IntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505 -APS Photoelectric Smoke Detector, or SD505 -AIS Ionization Smoke Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF /transient suppression techniques shall be employed to minimize false alarm potential. Diameter= 5- 15/16" \ SllF.ihT '' Model S13505 -6AB Detector Base (Front View) Diameter = 3- 15115" H 0i J Height = 2 inches, including base Model SD505 -AHS Detector Head (Front View) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350229 Rev B,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. SD500 -AIM & SD -500 -M I M Addressable Input Modules IntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500 -AIM and SD500 -MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500 -AIM and SD500 -MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500 -AIM and SD500 -MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation —a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763 -493 -6435. Description The SD500 -AIM and SD500 -MI1vI are addressable input modules for use with the Intelliknight fire alarm control panels (FACPs). The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACR Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features • Single contact monitor • Up to 2500 ft wiring distance from either input module to contact • Use up to 14 gauge wire • UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 50Q max Mechanical Specifications SD500 -AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1" D (12.4Wx 12.4 H x 2.5 D cm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500 -MIM Physical Description Dimensions: 1.5' W x 2.5" H x 0.7" D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) • Support for Class A (Style 6 & Style Environmental 7) or Class B (Style 4) wiring Operating Temperature: • Attractive ivory cover plate with the 32 °F — 120 °F (0 °C — 49 °C) SD500 -AI M • Small and lightweight size allows for Humidity: o 10% — 93% non - condensing flexible mounting options with the SD500 -M I M • DIP switch programmable for fast installation SD500 -MIM Approvals NFPA 71 & NFPA 72 UL 864 CSFM 7300-0559:132 MEA 429 -92 -E Vol. IX FM Approved for use with the 5820XL 13 SILENT KNIGHT by Honeywell The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500 -AIM or SD500 -MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500 -MIM shall fit inside a single gang electrical box. The SD500 -AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4 "- square or double gang electrical box. The SD500 -AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Tuamlw GcIng �.oni and is .►,. a At L•trinfl ra sincrised Ptrr-C- Ltm+totl NJTo wnLad 4,Tk £UL l O ___.mow....,{ Compatibility Ordering Information IntelliKnight 5820 FACP SD500 -AIM Input Module IntelliKnight 5808 FACP Addressable input module with ivory IntelliKnight 5700 FACP cover plate. SD500 -MIM Mini Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all 131 specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev.C, 05/06 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright ©2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. r= �'..,, ✓;',.yea s � ?,`'.� . l Tuamlw GcIng �.oni and is .►,. a At L•trinfl ra sincrised Ptrr-C- Ltm+totl NJTo wnLad 4,Tk £UL l O ___.mow....,{ Compatibility Ordering Information IntelliKnight 5820 FACP SD500 -AIM Input Module IntelliKnight 5808 FACP Addressable input module with ivory IntelliKnight 5700 FACP cover plate. SD500 -MIM Mini Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all 131 specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev.C, 05/06 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright ©2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. 5860 Remote Annunciator Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built -in annunciator. The 80- character display and ergonomically designed keypad allow for simple and error -free system operation. All operations — including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763- 493 -6435. Description Features include an 80- character backlit LCD providing easy -to- understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features • 80- character backlit LCD display (4 lines with 20 characters on each line) • Tactile and audible feedback • Accepts user codes or fire fighter's key • Larger keypad buttons for system reset and silence • Install up to eight 5860s per FACP • Available in red or light gray • Support for simultaneous use of multiple 5860s • RS-485 interface to panel • Operation and appearance is identical to 5860 built -in annunciator • On -board piezo sounder audibly indicates alarms, troubles, and supervisories • Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions • Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) • UL listed, complies with NFPA 72 • CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 Ibs (1.3 kg) 5860 Color 5680R: Red 5680: Gray Environmental Operating Temperature: 32 °F – 120 °F (0 °C – 49 °C) Humidity: 10% – 93% non - condensing Approvals NFPA 72; UL Listed; CSFM 7170 -0559: 135; MEA 429 -92 -E Vol. IX; FM Approved U SILENT KNIGHT p by Honeywell �T'dyvf The main control must have a built -in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built -in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built -in annunciator. All annunciators must have an 80- character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Compatible IntelliKnight FACP Compatibility IntelliKnight 5820XL FACP IntelliKnight 5808 FACP IntelliKnight 5700 FACP Wire Runs Up to 6000 Feet From FACP µ � Up to Eight 5860s Per System Ordering Information 568OR Remote Annunciator Four line LCD annunciator with 20 characters per line. Red. 5680 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring For surface mounting. 5860TG Gray Trim Ring For surface mounting. SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 55369 -4927. Phone: (800) 328 -0103, Fax: (763) 493 -6475. MADE IN AMERICA FORM# 350224 Rev C, 05/06 Copyright © 2006 Silent Knight �44, zoll 7, u r t. ` x.. ill t 5860 5860 5860 Up to Eight 5860s Per System Ordering Information 568OR Remote Annunciator Four line LCD annunciator with 20 characters per line. Red. 5680 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring For surface mounting. 5860TG Gray Trim Ring For surface mounting. SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 55369 -4927. Phone: (800) 328 -0103, Fax: (763) 493 -6475. MADE IN AMERICA FORM# 350224 Rev C, 05/06 Copyright © 2006 Silent Knight COOPER Notification Series AS Audible Strobe Appliances and Series AH Audibles Description The Wheelock patented 2 -wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi - candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi - candela ceiling strobe with field selectable intensities of 15130/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. "` I FM �L �R 1 0 M EA APPROVED E5946 151 -92 -E 7125- 0785:131 S5391 SERIES AH Features • Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information • ADA/NFPA/UFC /ANSI Compliant • Wall mount models are available with Field Selectable Candela Settings of 15/30175/110cd or 135/185cd (Multi - Candela models) or 1575cd (single candela model) • Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (multi - candela ceiling models) • Selectable Continuous Horn or Temporal (Code 3). • 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones • Patented 2 -Wire Audible Strobe Appliance. • Patented Universal Mounting Plate • Weatherproof models are available for outdoor use • Strobes produce 1 flash per second over the regulated voltage range • 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage • Synchronize using the Wheelock Sync Modules or panels with built -in Wheelock Patented Sync Protocol • Fast installation with IN /OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol .A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (± 2 %). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Ratings Per UL 1971 AH 12 and 24 VDC Audible Model Number Input Voltage VDC Regulated Voltage Range VDC /FWR Strobe Candela (cd) AS -24MCW 24 16.0-33.0 15/30/75/110 AS- 24MCCH 24 16.0-33.0 115/177 AS- 241575W 24 16.0-33.0 15 (75 on Axis) AS- 121575W 12 8.0-17.5 15 (75 on Axis) AS -24MCC 24 16.0-33.0 15/30/75/95 AS- 24MCWH 24 16.0-33.0 135/185 ASWP -2475W 24 16.0-33.0 75 @ -31-F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Audible Wall Mount Audible Strobe Models Reverberant Anechoic Description Volume dB dBA AS -24MCC AS- 24MCCH per 4464 @10ft 1575cd 15cd @10 ft. 75cd 110cd High 91 99 Continuous Medium 88 95 Horn High (99) 24 vdc 0.062 Low 83 90 0.150 0.194 High 87 99 Medium 84 95 Code 3 Horn r- Low 79 90 0.080 Table 3: Average RMS Current 12 vdc Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH -24 AS- 241576W AS -24MCW AS- 24MCWH AS -24MCC AS- 24MCCH UL max* 0.108 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd High (99) 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 dBA UL max* 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Med (95) 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 dBA UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low (90) 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 dBA UL max* 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 12 VDC Models Audible Wall Mount Audible Strobe Table 4: Average Current* (AMPS) For Series ASWP" AH -12 AS- 121575W High (99) 12 vdc 0.163 0.260 UL max* 0.192 0.320 dBA Med (95) 12 vdc 0.076 0.195 UL max* 0.108 0.275 dBA Low (90) 12 vdc 0.039 0.175 UL max* 0.058 0.265 dBA * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS currentwithin the listed voltage range (16 -33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Voltage High dBA Setting (99) dBA Medium dBA Setting (95) dBA Low dBA Setting (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max* 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS currentwithin the listed voltage range (16 -33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams # SERIES AS APPLIANCES NON - SYNCHRONIZED FROM❑ TO NEXT❑ PRECEDING❑ + ± +0 ppLIANCE❑ APPLIANCE❑ OR EOLR❑ OR FACP❑ +❑ y SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS- 12124 -8CP and PS- 12124 -8MP OUTPUTS. v EOLRO F ❑ 1 -40 4- CLASSO A❑ BO OR. A80 k550 co 2- CLASS. -A "O P❑ ASO P1:A series PS- 12/24 -8 PO o[ PS- 12/24 -8MP SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE SM❑ F❑ +OSTROBEO - OSTROBEO A❑ Strebe. NAC. Circuity AS C❑ _,(+Wudib3 e0 P❑ EOLRO Audible0 -ALdib eO NAC. CircuitO SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES Specifications and Ordering Information DSM Interconnecting wiring shown. Maximum twenty (20)0 * For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS- 24 -8MC. Model Number Order Code Strobe Candela Non- Sync Sync w /SM, DSM or PS- 24 -8MC VC D 12 VDC Wall Mount Ceiling Mount Mounting Options''* Agency Approvals UL MEA CSFM FM BFP AS- 24MCW -FR 9024 15130/75/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS- 24MCW -FW 9025 15/30175/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS- 24MCWH -FR 3468 135/185 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X AS- 24MCWH -FW 3469 135/185 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X AS- 241575W -FR 7405 15 (75 on Axis) X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS- 121575W -FR 7410 15 (75 on Axis) X X - X X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS- 24MCC -FR 3161 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X AS- 24MCC -FW 3162 15/30175/95 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X AS- 24MCCH -FW 3467 115/177 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X " ASWP- 2475W -FR ** 9012 75 @ -31 eF X X X - X - I (see Data Sheet S9004) X X X X X AH -24 -R 7892 - X X X - X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH -24 -W 7893 - X X X - X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH -12 -R 7891 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH -12 -W 7894 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH- 24WP -R ** 7416 - X X X - X X K X X X X AH- 12WP -R ** 7415 - X X - X X X K X X X X * *For Weatherproof Series AS /AH specifications see data sheet 59004. *PENDING ** *Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing- Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi - Candela appliances are specified, the strobe intensity shall have Feld selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135 /185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built -in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash -rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S8100 AS/AH 10107 Cooper Notification is Wheelock' MEDC SAFEPATH' WAVES a COOPER Notification COOPER Notification Series RSS and RSSP Strobes and Strobe Plates tlId J jr- NMI �r F. RE Series RSS Series RSS Series RSSWP RSS Round Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi - candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi - candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi - Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. 0 mccm 0 <*> M EA APPROVED S5391 151 -92 —E 7125- 0785:141 7300 - 0785:154 Features • Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory. Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information • ADA/NFPA/UFC /ANSI compliant. Meets OSHA 29 Part 1910.165 • Wall mount Multi - Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd • Ceiling mount Multi- Candela models are available with field selectable candela settings of 15/30/75/95cd or 1151177cd. (Round or Square) • Strobes produce 1 flash per second over the regulated voltage range • 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage • Synchronize using the Wheelock sync modules or panels with built -in Wheelock Patented Sync Protocol • Fast installation with IN /OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datatsheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes; • Strobes are designed to flash at 1 flash per second minimum over their `Regulated Voltage Range'. Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93 % (± 2 %). • Series NH homs are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Average RMS Current* RSS /RSSP 241675W 24VDC Models 1575cd UL max* RSS /RSSP 24VDC Models 12 vdc UL max* 0.090 RSS /RSSP Wall Mount RSS /RSSP - Wall Mount 24MCW I 24MCWH Ceilinq Mount 24MCC I 24MCCH 15cd 130cd 1 75cd 1110cd 1135cd 1185cd 115cd 130cd 1 75cd 195cd 1115cd 1177cd 0.060 10.092 1 0.165 1 0.220 1 0.300 1 0.420 10.065 1 0.105 1 0.189 10.249 1 0.300 1 0.420 * RMS current ratings are per UL average RMS method. UL max current 121575W rating is the maximum RMS current within the listed voltage range (16 -33v for 24v units). For strobes the UL max current is usually at the minimum 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2: Audibles /Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB- G6 /G10 Speakers ET- 1010/1080, E70, ET70 Chimes CH70 SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE 0 NAC SYNC_ 0 CIRCUIT OUT atoui1 +IN1 RSS RSS RSS \ FACP MINUS 1 O +AUDIBLE MINUS 2 +IN2 RSS RSS RSS TROBE NAC +ourz CIRCUIT RETURN Wiring Diagrams 9 SERIES RSS /RSSP APPLIANCE FROM + + TO NEXT PRECEDING - APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Sync Strobe NAC Cir. , + RSS RSS F -- DSM #2 A Strobe NAC Cir. SY+ RSS RSS C DSM #3 P I Strobe NAC Cir. Nffl3zRSo DSM Interconnecting wiring shown. Maximum of twenty (20) STROBE /PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM + + APPLIANCE PRECEDING - - OR EOLR APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP STROBE AUDIBLE STROBE /PLATE ASSEMBLY SM MODULE SINGLE AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM -.F -1- TO NEXT PRECEDING + STROBE APPLIANCE APPLIANCE OR _ Color WHITE Strobe - OR EOLR FACP UL RSS RSS Circuit C FROM + - — 1 r — — — BFP — — — -I-To NEXT PRECEDING - Audible STROBE OR STROBE, SYNC - - —T-' 1 r — — - — — — EOLR MODULE, POWER Square X X SUPPLY OR FACP X X RSS - 24MCW -FW 9401 X - X 1+-1 0 + - X STROBE APPLIANCE Square 11 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. Forwiring information on the power supplies refer PS- 24 -8MC. Specifications and Ordering Information SERIES RSS /RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT Ceiling Mount SM F + STROBE 12 VDC STROBE Color WHITE Strobe A NAC UL RSS RSS Circuit C FM BFP +Audible P S EOLR - Audible SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH PS- 12/24 -8CP or PS- 12/24 -8MP Series PS -17124 -8MP ImOUTPUTS AS F 1-4 4 -CLASS A 'B' OR AS RSS C 2 -CLASS A' P AS RSS Series PS -12124 -BMP Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options*'* Square or Round Agency Approvals UL MEA CSFM FM BFP RSS - 24MCW -FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS - 24MCW -FW 9401 X - X 15/30175/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 241575W -FR 7471 X - X 15 (75 on Axis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 241575W -FW 7788 X - X 15 (75 on Axis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 121575W -FR 7476 X - X 15 (75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 121575W -FW 7468 X - X 15 (75 on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS - 24MCC -FW 3158 - X X 15/30/75/95 X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS - 24MCC -FR 3157 - X X 15130175/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X I X RSS- 24MCCR -FW 3160 - X X 15/30175195 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X RSS- 24MCCH -FW 3461 - X X 115/177 X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS- 24MCCHR -FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X RSS - 24MCWH -FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS - 24MCWH -FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSSWP- 2475W -FR ** 9013 X - X 180@ 77 -F 75@ -31 °F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP- 2475W -FW`* 3034 X - X 180@7° 77 -F 75@ -31 °F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSP- 121575W -FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X X X X X RSSP - 24MCW -FR 9402 X I X 1 15/30/75/110 X X - D,E,Z Square X X X X X RSSP- 241575W -FR 177931 X I X 15 (75 on Axis) - - X - D,E,Z Square X X X X X *PENDING All models sync with Wheelock SM, DSM or PS- 12/24 -8CP or PS -12/24 -8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. * *For Weatherproof Series RSS Strobe specifications see data sheet S9004. ** *Refer to data sheet S7000 for mounting options. Architects ana The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing - Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built -in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single - gang, double -gang, flinch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi - Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox forflush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA SO410 RSS /RSSP 02/08 Cooper Notification is Wheelock' MEDC SAFEPATH° WAVES, COOPER Notification 5499 Distributed Power Module U The NAC expander that packs quite a combination punch, a whopping nine amps and built -in synchronization for appliances The 5499 Distributed Power Module by Silent Knight is the most - powerful and cost - effective power supply available today. It delivers 9 amps of notification appliance circuit power and built -in synchronization for appliances from System Sensor@, AMSECO, Faraday, Gentex@, and Wheelock@ — what you need to drive power -hungry components like ADA notification appliances. The 5499's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5499 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost - effective notification power supply available, you need the 5499. Call Silent Knight today for more information at 1- 800 -446 -6444. Description The 5499 is a 9 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls that have 9 -32 VDC outputs, such as the Silent Knight Model 5208 Fire Control /Communicator. The 5499 is the cost - effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5499 has built -in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features • UL Listed for 9 amps of notification power • Built -in synchronization for appliances from System Sensor®, AMSECO, Faraday, Gentex®, and Wheelock® • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • Dip switches allow for easy reconfiguration • 24 VDC filtered output voltage • Four power - limited notification outputs; 2 Class A (Style Z) or 4 Class B (Style Y), or 1 Class A and 2 Class B • Additional continuous auxiliary output • 3 amps per output circuit • 2 inputs; 2 Class B (Style B) or 2 Class A (Style D) • Ground fault detector /indicator • Independent trouble relay • AC loss delay option shuts off power to non - essential high- current accessories like magnetic door holders • Stand alone operation. • Lightweight design adds to ease of installation and reduces shipping costs • Operates with most polarized, UL Listed notification devices • ANSI Cadence pattern output capability built -in Connection to Local Fire Control Firepower 5499 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5499. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the Firepower 5499, which provides supervision between the 5499 and the fire control panel. Polarized audible and /or visual notification devices are then connected to the 5499 signal circuits using the 4.7kW end -of -line resistors provided. Since the 5499 draws very little power from the control, it is possible to connect one Firepower 5499 5499 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. SILENT KNIGHT by Honeywell 5499 Distributed Power Module Supervision The 5499 supervises a variety of functions including: • Low AC power. • Low battery condition. • Earth ground fault. • Auxiliary output power limit condition. • EOL supervision trouble or power limited condition at an output. When a trouble condition occurs, Firepower 5499 creates a trouble condition on the host control signal circuits to which it is connected. Firepower 5499 still maintains the ability to be activated by the host control. In addition, the 5499 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Electrical Specifications AC Input: 120 VAC at 3.OA Output: 24 VDC at 9 A Current Standby: 75 mA Alarm: 205 mA Auxiliary Power Circuit: 1 Notification Circuits: 4 Output Configuration: 2 Class A (Style Z) 4 Class B (Style Y) (1 Class A & 2 Class B) Amps Per Output: 3.0 (9.0 amps total) Notification Circuit Output: 20.4 to 27.3 VDC @ 3.0 amps each, 4.7 kS2 EOL resistor required on each Class B circuit No. of Inputs: 2 Input Configuration: 2 Class B (Style Y) or 2 Class A (Style Z) Input Voltage Range: 9 - 32 VDC Battery charging Capacity: 35.0 AH Mechanical Specifications Dimensions: 12.25" W x 16" H x 3" D 30.88 cm W x 40.64 cm H x 7.62 D cm Operating Temp: 32° to 120° F (0° to 49° C) Humidity: 93% non - condensing max. Indicator Lights AC power on : Green Battery trouble: Yellow Ground fault: Yellow Aux Trouble: Yellow Output troubles (1 -4): Yellow Installation Surface mount Approvals NFPA 72 UL Listed CSFM 7300-0559:123 MEA 429 -92 -E Vol. XI I Ordering Information 5499 Distributed Power Module Model 6499 Block Diagram Signal Circuit Output 51 pals npu Si nal2 Mtributed tpert Signal Circuit Ou Power _ aput hWule $419 Trouble output t.ocaI Fire Control (Alternative to notification circuit trouble,) Signal 1 Signal 2 Signal 3 Signal Aux. Pourer SILENT This document is not intended to be used for installation purposes. We try to INIG T keep our product information up -to -date and accurate. We cannot cover all 13 specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight vlcit 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Phone: (800) 328 -0103, Fax: (763) 493 -6475. MADE IN AMERICA FORM# 350396 Rev D 09/06 Copyright © 2006 Silent Knight