Loading...
HomeMy WebLinkAbout3101 W 1st St 08-2128 (fr sp)C) " -4,1— P CITY OF SANFORD PERMIT APPLICATION �.' ,Qlic Address: #: - - r , 1 I S � -- Submittal Date: 0 7 - 0 9 - 0 8 f /�� 11 b Address: 31 01r— $�t$A�id= Value of Work: $ 15,829.00 �+ Q arcellD: 26- 19- 305AE -330A -0000 Zoning: g� Historic District: Description of Work: ADD AND RELOCATE THROUGHOUT THE 2ND F� quare Footage: ..................... AND+.. .. ..ZLMR7. ........ ............................... Permit Type: Building IN Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler /AlarmXX Pool ❑ Sign ❑ Electrical: New Service - # of AMPS Addition/Alteration I'd Change of Service ❑ Temporary Pole ❑ Mechanical: Residential El Non-Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water &Sewer Lines # of Gas Lines /Plumbing/New Residential: # of Water Closets Plumbing Repair- Residential ❑ Commercial ❑ Occupancy Type: Residential ❑ Commercial [2[ Industrial ❑ Occupancy Use Group(s): .Construction Type: - - -- - - - - -- # of Stories: • • • ... •# of Dwelling Units:. - -- - - - - .Flood Zone:•.... • • • (FEMA form:: quir-ed ............... Property Owner: Address: Phone: Bonding Company: Address: Arch itect/Engineer: Address: Plan Review Contact Person: E -mail: Contractor: -SOUTHERN FTRF Address: 3801 E. SR 46 SANFORD, FL 32771 Phone: 3 2 3 - 4 2 0 0 State License Number: 740723 Mortgage Lender: Address: Phone: Fax: Phone: Fax: E -mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. �/ Signature of Owner /Agent Date signature of Contractor /Agen ate ROBERT H. CALDWELL,JR Print Owner /Agent's Name Signature of Notary-State of Florida Date Owner /Agent is_ Personally Known to Me or Produced ID Print Contractor /Agent's N 7 Signature pi}pricja,, �I,YPP4 Notary ^.;b4c hate of Florida Carme ;. u�isiore A1, Qa My Gommiss.on ,10784554 ?p, Expires 04130120^ ? Contractor e i r on Ily noW td""Ie o Produced ID APPROVALS: ZONING: UTIL: FD: ENG: BLDG: 1\� J Special Conditions: '� l Rev 07.07 CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407 - 302 -1091 * FAX #: 407 - 330 -5677 DATE: 2 & A -? PERMIT #: BUSINESS NAME / PROJECT: sr ADDRESS: _S / 01 W . j- $ / PHONE NO.: FAX NO.: CONST. INSP. [ ] C / 0 INSP. j ] REINSPECTION [ ] F. A. [ ] F. S. [ ] HOOD [ ] PAINT BOOTH TENT PERMIT [ ] TANK PERMIT [ ] OTHER [ ] _ TOTAL FEES: $ - S COMMENTS: Address / Bldg. # / Unit # 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. PLANS REVIEW [ ] BURN PERMIT [ ] (PER UNIT SEE BELOW) Square Footage Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, Fl. 32771 Phone # -407- 330 -5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. Sanford rver Division Applicant's Signature Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 Personal Property Please Select Account DAVID JOHNSON. CrA,ASA PROPERTY APPRAISER SEMINOLE COUNTY FL. 1101 E. RRs7r sT SAHFORo, FL3=1 -146B 407 -665 -7508 2008 WORKING VALUE SUMMARY Amendment 1 impact not reflected. GENERAL Value Method: Market Parcel Id: 26- 19- 30- 5AE -330A -0000 Number of Buildings: 1 Owner: CHURCH CENTRAL BAPTIST OF Depreciated Bldg Value: $2,116,900 Own /Addr: SANFORD Depreciated EXFT Value: $79,374 Mailing Address: 3101 1ST ST W Land Value (Market): $2,119,632 City,State,ZipCode: SANFORD FL 32771 Land Value Ag: $0 Property Address: 3101 1ST ST W Just/Market Value: $4,315,906 Facility Name: Assessed Value (SOH): $4,315,906 Tax District: S1- SANFORD Exempt Value: $4,315,906 Exemptions: 36- CHURCH /RELIGIOUS () Taxable Value: $0 Dor: 71- CHURCHES Tax Estimator Portability Calculator SALES 2007 VALUE SUMMARY Deed Date Book Page Amount Vac /Imp Qualified 2007 Tax Bill Amount: $0 WARRANTY DEED 11/1982 01425 0746 $225,000 Vacant No 2007 Taxable Value: $0 DOES NOT INCLUDE NON -AD VALOREM Find Sales within this DOR Code ASSESSMENTS LEGAL DESCRIPTION LAND PLATS: Pick... Land Assess Method Frontage Depth Land Units Unit Price Land Value LEG E 1/2 OF BLK 33 + E 1/2 OF N 210 FT OF SQUARE FEET 0 0 353,272 6.00 $2,119,632 BLK 34 + W 1/2 OF N 210 FT OF BLK 47 + W 1/2 OF BLK 48 (LESS RD) M M SMITHS SUBD PB 1 PG 55 BUILDING INFORMATION Bid Num Bid Class Year Bit Fixtures Gross SF Stories Ext Wall Bid Value Est. Cost New 1 MASONRY PILAS 1989 16 36,000 2 METAL PREFINISHED $2,116,900 $2,731,484 Subsection / Sgft OPEN PORCH FINISHED/ 1359 Permits EXTRA FEATURE Description Year Bit Units EXFT Value Est. Cost New COMMERCIAL ASPHALT DR 2 IN 1989 116,335 $55,579 $105,865 COMMERCIAL CONCRETE DR 4 IN 1989 6,500 $7,269 $13,845 POLE LIGHT CONCRETE 1 ARM 1989 14 $14,532 $14,532 ALUM CARPORT W /SLAB 2001 400 $1,994 $2,600 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. * ** If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value. http: / /www.scpafl.org /web /re_web.seminole_ county title ?PARCEL= 2619305AE33OA000O... 6/3/2008 2008- JUL -08 03:32PM FROM- WILSON COMPANY INC C. +407 365 0806 T -289 P.001 /001 F -855 Permit No. 081380 Tax Folio No. 2619305AE33OA0000 NOTICE OF COMMENCEMENT State of Florida County of Seminole The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of property: (legal description of the property, and street address if available) 2. General description of improvement: 3. owner information: Central Baptist Church of Sanford, FL Inc. Address: 3101 West First Street; State Road 46 Sanford, Florida 32771 b. Interest in property: Fee Simple c. Name and address of fee simple titleholder (if other than Owner): Name: Address: (� 4. Contractor Name: Wilson & Company, Inc. Phone number: 407 3G5 -0906 1\c. Address: 1231 East Broadway Street. Suite 100: Oviedo, FL 33765 5, Surety Name None Address: b. Amount of bond: S N.A. 6. Lender: Name: NONE Address: N.A. b. Lender's phone number: N.A. 7.a. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713,13(1)(a)7., Florida Statutes: Name: Caple Howden Address: 6911 University Blvd; Winter Park, FL 32792 8.a. In addition to himsclf or herself; Owner designates Parks Wilson of Wilson & Company, Inc. 1231 East Broadway Street, Suite 100: Oviedo, FL 32765o receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. b. Phone number of person or entity designated by owner: 407) 657 -8808 9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is specified) . WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUK PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTF -D ON THE JOB SITE BEFORE TI4E FIRST INSPECTION. IF YOU IN I ND TO OBTAIN qORD , CONSULT WITH YOUR LENDER OR AN ATTORNEY BEIFORE COMMENCING WORK OR R YOUR NOTICE OF COMMENCEMENT. Signature of Owner or Owner's Authorized Officer/Director /Parmer/Manader Signatur 's T hl /Office The foregoing instrument was acknowledged before me Ellis- ;72"'rday of �1 , (year , by(name o (type of authority, ... e.g. ofhcer,=.st • .attorney in fact) for (name of parry on beh executed) . (SEAL) rJ? •W Notary Public State of Florlaa `x��` !7 w `� Ann L Sullivan Signature of Notary Public —_ f ��r 1� My Commission DD7657o1 Personally Known OR Produced I eri ication Type of Identification Produced „ nod Expires 03130!2012 Verification pursuant to Section 92.525, Florida Statutes; Under penalties of perjury. foregoing and that the facts stated in it are true to the best owlcdge and beli E Signature of Natural Person Signing Above r'� Rev. date 3 /2008 MARYANNE MORSE, CLERK OF CIRCUIT COURT IMM OF SEMIN13LE COUNTY W x16999 Rg 0478; t 1 p g I FILE NUM c01:78060759 O R£t:+I3RDED 05/E3/2008 0,33 :07 RECRRDING FEES 18.00 KMRO D BY T Saith all I lttl at IIII In go? II Iota 11 Ili III loll II 1,7 I\ Inc it [on H Hl al 11211 AL - - - Fire Protection by Computer Design Southern Fire Protection 3801 E. SR 46 Sanford, FI 32771 -9155 407 - 323 -4200 Job Name Central Baptist Church Building Location 3101 W. SR 46 System 1 Contract 51589 Data File Calcs.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Cs7 N CO Cn N n cc: x, +,�. C/D LLi CO Southern Fire Protection ' Central Baptist Church Page 1 Date 07/03/2008 Hydraulic Design Information Sheet Name - Central Baptist Church T Time of Test - Location - 3101 W. SR 46 Date - 07/07/2008 Building - E Static Press - Contractor - Southern Fire Protection System No. - 1 of Orlando Inc Contract No. - 51589 Calculated By - Chad Reyes Drawing No. - 1 Construction: ( ) Combustible (X) Non - Combustible Ceiling Height - 8ft Occupancy - Church Flow - S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other 0 C T Specific Ruling Made By Date E - - - - -- - - -- Clearance:Storage to M Area of Sprinkler Operation - 1500 System Type Sprinkler /Nozzle Density - D Area Per Sprinkler - .1 (X) Wet Make Rasco 196 E Elevation at Highest Outlet - ( ) Dry Model F -1 9' -0" ( ) Deluge Size 1/2" S Hose Allowance - Inside - I ( ) Preaction K- Factor 5.6 Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 100 N Note plate riser Calculation Flow Required - 248.667 Press Required - 53.206 Base of Riser Summary C- Factor Used: 120 Overhead Underground W Water Flow Test: A Date of Test - Class Location Pump Data: Tank or Reservoir: T Time of Test - Rated Cap.- Cap. - Elev.- E Static Press - 70 @ Press - R Residual Press - 54.52 Elev. - Well Flow - 423.67 T A ( ) Mult. Row ( ) Open Shelf S Elevation - 0 C Proof Flow U - - - - -- - - -- Clearance:Storage to Ceiling A Longitudinal _ P Location - Base of existing 4" Riser -- - - - - -- -- P E Horizontal Barriers Provided: - -- - - L Source of Information - Existing hydraulic calculation on Y plate riser C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled o Palletized ° Rack M ( ) Single Row ( ) S R Conven. Pallet ( ) Auto. Storage - -- - -- — - ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf 0 C - — R K Flue Spacing ----------- - - - - -- - - -- Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: - -- - - Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Southern Fire Protection Page 2 Central Baptist Church Date 07/03/2008 Node Elevation K -Fact Pt Pn Flow Density Area Press No. _ Actual oe HD 1 8.0 5.6 12.25 na 19.6 8.0 K= K@ DROP 12.99 na 19.6 2 8.0 K= K@ DROP 13.64 na 20.09 3 8.0 K= K@ DROP 18.45 na 23.36 4 8.0 K= K@ DROP 21.57 na 25.26 5 8.0 K= K@ DROP 28.35 na 28.96 6 7 8.0 33.82 na 8 8.0 K= K@ DROP 14.29 na 20.56 8.0 K = K@ DROP 15.96 na 21.73 9 10 8.0 K= K@ DROP 23.0 na 26.08 11 8.0 K= K@ DROP 27.22 na 28.38 12 8.0 8.0 35.25 na 13 8.0 K= K@ DROP 37.98 40.58 na na 34.65 14 15 8.0 8.0 41.78 na C1 8.0 42.19 na C2 8.0 40.45 na C3 8.0 40.99 na TR 8.0 42.64 na BR 8.0 52.42 na 53.21 na The maximum velocity is 19.94 and it occurs in the pipe between nodes 10 and 11 0.1 196 12.25 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen - Williams Southern Fire Protection Page 3 Central Baptist Church Date 07/03/2008 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv * * * * * ** Notes * * * * ** Point Qt Pf /Ft Eqv. Ln. Total Pf Pn HD 19.60 1.08 1T 5.762 1.001 12.250 to -- 20.56 120.0 0.0 5.762 0.0 DROP _ 19.6 0.1088 1.664 6.763 0.736 10 - - -- 68.37 10 28.38 to 0.0 11 19.60 11 0.0 12.986 1 19.60 1.08 0.0 6.001 12.986 to 96.75 120.0 0.0 0.0 0.0 ? _ 19.6 0.1086 0.0 6.001 0.652 2 20.09 1.08 0.0 12.001 _ 13.638 to 35.248 120.0 0.0 0.0 0.0 3 -__ 39.69 0.4012 ___0.0 12.001 4.815 3 23.36 1.408 _ 0.0 12.001 _ 18.453 to 0.0 120.0 0.0 0.0 0.0 _ 4 _ 63.05 0.2597 0.0 12.001 3.117_ 4 25.26 1.408 0.0 _ 13.999 _ 21.570 to 120.0 0.0 0.0 0.0 5 88.31 0.4842 0.0 13.999 6.779 5 28.96 1.639 0.0 13.999 28.349 to 120.0 0.0 0.0 0.0 6 _ _ 117.27 0.3905 _ -- 0_0 -_ 13.999 5.467 6 0.0 1.639 1T 8.727 _ 8.251 33.816 to 120.0 0.0 8.727 0.0 C1 _ 117.27 0.3905 0.0 16.978 6.630 K Factor = 5.60 Vel = 6.86 K Factor= 5.44 K Factor @ node DROP Vel = K Factor @ node DROP Vel = 13.90 K Factor @ node DROP Vel = 12.99__ _ K Factor @ node DROP Vel = 18.20 K Factor @ node DROP Vel = 17.83 Vel = 17.83 K Factor _= 18.4_4 K Factor @ node DROP Vel = 7.20 K Factor @ node DROP Vel = 14.81 K Factor @ node DROP Vel = 14.09 K Factor @ node DROP Vel = 19.94 Vel =-.14.7 I Vel = 14.71 40.988 K Factor = 15.11 1.408 0.0 13.999 40.576 K Factor @ node DROP 120.0 0.0 0.0 0.0 0.0858 0.0 13.999 1.201 Vel = 7.14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 0.0 117.27 7 20.56 to 0.0 8 - - -_ -- 20.56 8_ 21.73 to 0.0 9 -- - - - 42.29 - -- -- -26.08 9 1.664 to 2E 4.61 10 - - -- 68.37 10 28.38 to 0.0 11 96.75 11 0.0 to 0.0 12 96.75 12 0.0 to 0.0 C2 96.75 - 13.999 0.0 1.408 96.75 13 34.65 to 0.0 14 34.65 K Factor = 5.60 Vel = 6.86 K Factor= 5.44 K Factor @ node DROP Vel = K Factor @ node DROP Vel = 13.90 K Factor @ node DROP Vel = 12.99__ _ K Factor @ node DROP Vel = 18.20 K Factor @ node DROP Vel = 17.83 Vel = 17.83 K Factor _= 18.4_4 K Factor @ node DROP Vel = 7.20 K Factor @ node DROP Vel = 14.81 K Factor @ node DROP Vel = 14.09 K Factor @ node DROP Vel = 19.94 Vel =-.14.7 I Vel = 14.71 40.988 K Factor = 15.11 1.408 0.0 13.999 40.576 K Factor @ node DROP 120.0 0.0 0.0 0.0 0.0858 0.0 13.999 1.201 Vel = 7.14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - -- 40.446 1.08 0.0 _ 13.999 14.292 120.0 0.0 0.0 0.0 0.1189 0.0 _ _ 13.999 1.664 1.08 2E 4.61 _ 11.001 _ _ 15.956 120.0 0.0 4.610 0.0 _ 0.4512 0.0 7.044 1.408 0.0 _15_611 13.999 23.000 120.0 0.0 0.0 0.0 0.3016 _ 0.0 - -- - 13.999 4.222 1.408 0.0 13.999 _ 27.222 120.0 0.0 0.0 0.0 0.5733 0.0 13.999 8.026 1.639 0.0 10.000 35.248 120.0 0.0 0.0 0.0 0.2736 0.0 10.000 2.736_ 1.639 1 T 8.727 2.251 37.984 120.0 0.0 8.727 0.0 0.2736 - 0.0 10.978 3.004 K Factor = 5.60 Vel = 6.86 K Factor= 5.44 K Factor @ node DROP Vel = K Factor @ node DROP Vel = 13.90 K Factor @ node DROP Vel = 12.99__ _ K Factor @ node DROP Vel = 18.20 K Factor @ node DROP Vel = 17.83 Vel = 17.83 K Factor _= 18.4_4 K Factor @ node DROP Vel = 7.20 K Factor @ node DROP Vel = 14.81 K Factor @ node DROP Vel = 14.09 K Factor @ node DROP Vel = 19.94 Vel =-.14.7 I Vel = 14.71 40.988 K Factor = 15.11 1.408 0.0 13.999 40.576 K Factor @ node DROP 120.0 0.0 0.0 0.0 0.0858 0.0 13.999 1.201 Vel = 7.14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen - Williams Southern Fire Protection Page 4 Central Baptist Church Date 07/03/2008 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv * * * * * ** Notes * * * * ** Point Qt Pf /Ft Eqv. Ln. Total Pf Pn 14 0.0 1.639 0.0 10.000 41.777 to 120.0 0.0 0.0 0.0 15______ 34.65 0.0409 0.0 10.000 0.409 Vel 5 0.0 1.639 1 T 8.727 2.251 42.186 to 120.0 0.0 8.727 0.0 C3 34.65 0.0410 0.0-- 10.978 0.450 Vel = 5.27 34.65 42.636 K Factor = 5.31 C1 117.27 2.635 0.0 13.999 40.446 to 120.0 0.0 0.0 0.0 C2 117.27 0.0387 0.0 13.999 0.542 Vel = 6.90 C2 96.75 2.635 0.0 13.999 40.988 -- -- - -- to 120.0 0.0 0.0 0.0 C3 214.02 0.1177 0.0 13.999 1.648 Vel = 12.59 C3 34.65 2.635 2E 16.474 30.000 _ 42.636 to 120.0 1T 16.474 32.948 0.0 TR - 248.67 0.1554 0.0 62.948 9.780 Vel = 14.63 TR 0.0 4.26 1 B 15.8 7.999 52.416 - -- -- - to 120.0 1S 28.968 44.768 0.0 BR 248.67 0.0150 _ 0.0 52.767 0.790 Vel = 5.60 0.0 - - - -- - -- - - 248.67 _ 53.206 K Factor= 34.09 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram Southern Fire Protection Page 5 Central Baptist Church Date 07/03/2008 19.6 HD <- DROP 19.6 63.1 117.3 1 <- 2 <- 3 F 4 F 5 <- 6 F C1 39.7 88.3 11713 117.3 i I i 20.6 68.4 96.8 1 7 F8 <-9 F10 <-11 F12 <-C2 42.3 96.8 964 1 214 I I I I 34.6 34.E 13 <-14 <-15 <-C3 34.6 T 1 248.7 I I I i I TR T 1 248.7 I BR Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 / \ 0 �o � o\ %q So 10, ICN� 7k $® \± m_ cu/ .............. t 2 � E aU- IL =EEgE[. cu k£i��2 �ff�mfZ' r_�q§§nt 3Ocommom E / q� /$U .. § .. 2= kk� \/ � cc cc 0 X277 { \T \ \Iƒ > \3 koo\ } D f_ , // / # / # 2 n $ o/ 0Z $ O ƒ 0 2 & \ / 0 v � / c o 0 0 0 0 LO / / 2 Q / ? / / 0 / ? / \ / E a ± 3 @ 2 ± ± 2 0 < / 5 2 E f 7 \ \ ƒ Li \ \ i � E @ / E \ _ E / R�IIs7b1� The Designer° Model F1 Sprinkler Standard Upright Standard Pendent Extended Coverage Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW1 Deflector The Designeell Model F1 Recessed Sprinkler Recessed Pendent Recessed Extended Coverage Pendent Approval Organizations 1. Underwriters Laboratories Inc. 2. Underwriters' Laboratories of Canada 3. Factory Mutual Research Corp. 4. Loss Prevention Council 5. NYC BS &A No. 587 -75 -SA 6. Pleniere Assemblee 7. Verband der Schadenversicherer 8. NYC MEA 258 -93 -E UL Listing Category Sprinklers, Automatic & Open (VNIV) Patents: U.S. Patent No. 6,374,92 Applies to Model F1 Vertical Sidewall Sprinklers. Product Description The F1 Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceiling, it is functional and attractive. The Horizontal and Vertical Sidewall Sprinklers provide an equally attractive appearance when ceiling piping cannot be used. Beautifully versatile is the description for the Reliable Model F1 Recessed Designer glass bulb sprinkler. Recessing The Designer® enhances its already low profile decorative appearance, and facilitates a rapid and perfect installation. Model F1 Recessed Designer's escutcheon is highly adjustable. The two piece construction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus facilitating maintenance of above ceiling services. The Designer ®Automatic Sprinkler utilizes a frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside of a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. Bulletin 117 Rev.S Model F1 Model F1 Recessed Standard Response Sprinklers rte` � Upright s� 'Fs �Y Pendent ate` Vertical Sidewall Conventional •A y t� Horizontal Sidewall Recessed Pendent Extended Coverage Recessed Extended Pendent Coverage Pendent At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F1 Sprinkler temperature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York. 10523 Model F1 Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Upright Installation Data: Pendent Nominal I Thread Size I Nominal K Factor I Sprinkler Approval I Sprinkler Identification Numbers Orifice us Height Organization (SIN) Upright Pendent Metric standard-1-1 right (SSU) and pendent Deflectors Marked to Indicate Position (15mm) NPT i (R1 /2) 5'6 1 80 ! (5Gmm) 1,2.3,4,5,6.7 R11725''' 81715 17/32°) I (20mm (R3 4)T' I 8.0 115 I 2.3' (58mm) 1,2,3,4,7,8 R1722") I P. 1712 %'2 I (15mm)"' ( NPT (R1 /2) 0.6 80 2.2' 7 _ 17/32' 1 (20mm)('-1 i zW NPT (R3 /4) 8.0 115 I 2.3' — - -- -- -- -' -- 7 ----- - -�. —_ (58mm) 7.116' ! (11mm) ; "," NPT (R1/2) 4'? 60 (56mm) 1,2.8 - R1723") R1713 3 /8' (10mm) % -' NPT (R1/2)(° i 2.8 j 40 (65mrn) 1,2,8 I 81721 "1 81711 10mmXLH I R3 /6 I 42 60 ; 56.1 mm 4,6,7 R1724 I R1714 Convenlional- Install in upright or Pendent Position 10mmXLH ; -- -- - - - - -- R3 /8 -- - - - - - -- - - I- 4.2 60 ! 56.1 mm - - - - - -- 81774 15mm I ` %a° NPT (R1 /2) 5.6 80 1 56.1 mm 4,6,7 R1775 20mm W NPT 1 (R3/4) 8.0 115 58.1mm 4,7 81772 (1) LPC Approval up to 286 °F (141 °C) (2) FM Approval for SSU up to and including 200 °F (93 °C) only. (3) (F1S5) VdS Approval for Intermediate Response 155 °F (68 °C) only. (4) Polycoated upright UL and ULC listed corrosion resistant. 2. Model F1 Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench riu,uessea renoeni Installation Data: ,/4" NOLC CIa. (as.amm) TURN COLLAR UIJrIL NOM 1 �/ AOLrl$r 5FRIN,ILCR ItfiChmN &055 — LF is Lv,•Srsrer. �!/ i 03Sdt1 1.700]4 Z 7i, 31" C+ (1) When installed directly into a tee, the escutcheon dimension's adjustment will be reduced. Nominal Nominal K_ Factor i Orifice Thread Size _ -- r Sprinkler Height Approval Sprinkler Identification us I Metric Organization Numbers (SIN) (15mm) '.•z' (R1/2) NPT � 5.6 1 80 � j (56mm) 1,2.3.4,5,7 I R1715 17/32' (20mm) ?4• NPT (R3!4j I 8.0 I 115 2.3' (58mm) 1,2.3,4,8 R1712 (15 M)' '. In" Iv PT I _ �•6 i 80 j (56mm 7 I i 17/32" 0mm)' %' IJPT 3 / 8.0 __L - - - - - - -- (58mm) r 7!16• ( 11 mm) V2 • IVPT (R1/2) 4.2 1 ! 60 2.2' (56mm) 1 —'.8 R1713 3/8' (10mm) z hJPT I (R1/2J 2.8 40 i 2.2' (56mm) 1 1,2,8 R1711 10mm R3/8 4.2 I 60 56.1mm 4,7 I R1714 lZJ I-IVI Approval • Light Hazard - No Limitations • Ordinary Hazard - Groups 1 & 2, Wet Systems only. (3) LPC Approval is for 570C through 930C ratings. (4) VdS Approval for Intermediate Response 155F (68 °C) only. 3. Model F1 & F1 Recessed Sprinklers Application Model F1 and F1 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction, Installation Model F1 sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F1 Recessed Sprinklers are to be installed with a maximum recess of 3/ inch (19mm). The Model F1 Escutcheon illustrated is the only recessed escutcheon to be used with the Model F1 Pendent and EC Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1 Recessed Pendent and EC Pendent Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. - Glass bulb sprinklers have orange covers to protect the bulb during the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Maintenance The Models F1 and F1 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Finish (where applicable) Temperature Ratings I Sprinkler Maximum j Classification j Temperature Ambient Temperature ! Bulb White Painted Special Application Finishes Sprinkler Color i °F 1 °C I °F °C Black Plated Ordinary 135 I 57 1 100 38 I Orange Ordinary 155 I 66 100 38 I Red Intermediate 175 79 150 66 Yellow Intermediate i 200 j 93 1 150 66 j Green High(') I 286 1 141 1 225 1 107 Blue Extra Kohl" 1 360 ; 182 300 149 Mauve (1) Not Available for F1 Recessed Patents: U.S. Patent No. 6,374,920 Applies to Model F1 Vertical Sidewall Sprinklers. Finishes(') Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome White Polyester ester Coatedt3Yb1 White Painted Special Application Finishes Sprinkler Escutcheon Bright Brass" 1 Bright Brass Black Plated Black Plated Black Paint "' Black Paint Off Whiter" Off White Satin Chrome Satin Chrome Lead Plated"" War. Coaled(3gsj 51 Wax Over Lead` `) (1) Other colors and finishes are available on special order. Consult factory for details. (2) 200 °F (93 °C) maximum. (3) UL and ULC listed, and NYC approved only. (4) 155 °F to 200 °F (68 °C to 93 °C) ratings only. (5) 286 °F (141 °C) sprinklers may be coated for ambient conditions not exceeding 150 °F (66 1C). (6) UL and ULC listed corrosion resistant SIN numbers: R1721, R1722, R1723 and R1725. Note: For 1/2" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 013. The equipment presented to this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association. Factory Mutual Research Corporation; or other similar orga applicable. nizations and also with the provisions of governmental codes or ordinances whenever Products manufactured and distributed by Reliable have been protecting life and property for over 80 vears, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. �';� �' (800) 431 -1533 Sales Offices (800) 848-605 i Sale =_ Fax (914) 829 -2042 Corporate Offices wva:v.r- - - espnnkler corr. internet Address Recycl ed Paper Revision lines incicate updated nr nev; data E.G. Printed in U.S.A. 31107 FIN 99999 700 1- Bulletin 112V W I. ® Model G Sidewall Model G /F1 Recessed 1 Sidewall Sprinklers < A Complete Line of Sidewall Sprinklers 1. Model G Vertical Sidewall- Upright. 2. Model G Vertical Sidewall- Pendent. 3. Model G Horizontal Sidewall -HSW1 Deflector. 4. Model G /F1 /HSW1 Recessed Horizontal Sidewall -HSW1 Deflector. 5. Model G Extended Coverage Horizontal Sidewall -EC4 Deflector. 6. Model G /F1 /EC4 Recessed Extended. Coverage Horizontal Sidewall- EC4Deflector 7. Variety of finishes. 8. Multiple orifice sizes. Product Description All Reliable Model G Automatic Sidewall Sprinklers uti- lize the center strut in compression principle of con- struction. The fusible alloy, retained in the cylinder of a small solder capsule by a stainless steel ball, acts as the trigger of the sprinkler. When the fusible al loymelts, the sprin klers op er at ing parts spring freefrom the sprin- kler, clearing the waterway and allowing the sprinklerto distribute the discharging water. Sidewall Sprinkler Types: Model G Vertical Sidewall Sprinkler The Model G Vertical Sidewall Sprinkler is designed for use in light hazard situations where standard sprinklers are deemed impractical because of decorative or structural conditions. It discharges approximately 15% of the wa ter on the wall be hind itwith the re main ing 85% discharged in front of the sprinkler. This sprinkler may be installed in either the Upright or the Pendent posi- tion. Model G Horizontal Sidewall Sprinkler - HSW1 Deflector This deflector configuration is designed and listed for use in either light or or di nary hazard oc cu pan cies. The use of the Model G HorizontalSidewallSprinklerinordi- nary hazard occupancies will provide installation sim- plicities and economies in many circumstances. T-- ; Model G VerticalUpright rYftfr s ��` u rare MFL9 WTI TV s Model G Extended Coverage -EC4 Model G /F1 /EC4 Model G /F1 /HSW1 Recessed Horizontal Recessed Extended Coverage —EC4 Horizontal -HSWi Model G /F1 /HSW1 Recessed Horizontal Sidewall Sprinkler -HSW1 Deflector The combination of the Model F1 Recessed Escutch- eon and the Model G Horizontal Sidewall Sprin- kler-HSW1 Deflector provides a very attractive recessed sprin klerfor use in light hazard oc cu pan cies. Model G Extended Coverage Horizontal Sidewall Sprinkler -EC4 Deflector The Model G Extended Coverage Sprin kler is listed for the protection of larger than normal areas in light haz- ard occupancies. Model G /F1 /EC4 Recessed Extended Coverage Horizontal Sidewall Sprinkler -EC4 Deflector The combination of the Model F1 Recessed Escutch- eon and the 'T32" (20mm) orifice x3/4" NPT (R3 /) Model G Horizontal Sidewall Sprinkler -EC4 Deflector provides a very attractive recessed sprinkler for use in larger than normal areas in light hazard occupancies. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York, 10552 Model G Extended Coverage Horizontal Sidewall Sprinkler - EC4 Deflector Technical Data Technical Data Length: 3%6' (84mm) - Y2" (15mm) Orifice Sprinkler 9%2' (90mm) -1%2' (20mm)OrificeSprin kler Rating: 135 °F (57 °C) Max. Ambient Temp. 100 °F (38 °C) Model G /F1 /EC4 Extended Coverage Horizontal Sidewall Sprinkler - EC4 Deflector Technical Data Nominal Orifice: 772" (20mm) Thread Size: % " NPT (R3 /a) K Factor: 8.20 US (118.2 Metric) Length: 31%2' (90mm) Rating: 135 °F (57 °C) Max. Ambient Temp.: 100 °F (38 °C) t Technical Data KFactor Deflector to Coverage Area Sprinkler Ident Coverage Area Ceiling Dimension Nominal i Thread Pressure Width x Length Flow Rate Pressure Width x Length Number Orifice Size US Metric gpm (Umin) psi (bar) ft. x ft. (m x m) (SIN) ' /z" (15mm) 1/" (R' /2) 5.62 81.0 30 (113.5) 28.5 (2,0) 16 x 18 (4.9 x 5.5) R1265 ' /2" (15mm) %2"(R1/2) 5.62 81.0 38 (143.8) 45.7 (3,2) 16 x 20 (4.9 x 6.0) R1265 172x' (20mm) %" (R3/4) 8.20 118.2 30 (113.5) 13.4 (0,9) 16x 18 (4.9 x 5.5) R1267 17 32 " (20mm) i 3/4" (R3 /4) 8.20 118.2 32 (121.1) 15.2 (1,0) 16 x 20 (4.9 x 6.0) R1267 1732' (20mm) X" (R3 /4) 8.20 118.2 37 (140.0) 20.0 (1,4) 16 x 22 (4.9 x 6.7) R1267 1732' (20mm) Y4 " (R3 /4) 8.20 118.2 39 (147.6) 22.6 (1,6) 16 x 24 (4.9 x 7.3) R1267 Model G /F1 /EC4 Extended Coverage Horizontal Sidewall Sprinkler - EC4 Deflector Technical Data Nominal Orifice: 772" (20mm) Thread Size: % " NPT (R3 /a) K Factor: 8.20 US (118.2 Metric) Length: 31%2' (90mm) Rating: 135 °F (57 °C) Max. Ambient Temp.: 100 °F (38 °C) t Technical Data Model G /F1 /EC4 Model G /F1 /HSW1 Re cessed Sidewal I Sprinkler Approval Type: Extended Coverage -Light Hazard Occupancy. Approvals: Underwriters Laboratories Inc. NYC BS&A No 587 -75 -SA Underwriters' Laboratories of Canada Installation Wrench: Model D Sprinkler Wrench. Color Identification: Black Paint (Bronze Finish Only). Ceiling to Deflector Distance: 6 to 12 inches (152mm to 305mm). Approval Type: Extended Coverage -Light Hazard Occupancy. Approvals: Underwriters Laboratories Inc. NYC BS&A No 587 -75 -SA Underwriters' Laboratories of Canada Installation Wrench: Model GFR1 Sprinkler Wrench. Color Identification: Black Paint (Bronze Finish Only). 2. Deflector to Coverage Area Ceiling Dimension Flow Rate Pressure Width x Length Min. - Max. Sprin klerident. gpm (L /min) psi (bar) ft, x ft. (m x m) in. (mm) Number(SIN) 30 (113.5) 13.4 (0,9) 16x18 (4.9x4.9) 6 -12 (152 -305) 32 (121.1) 15.2 (1,0) 16x20 (4.9x6.0) 6 -12 (152 -305) R1267 L 37 (140.0) 20.0 (1,4) 1 16x22 (4.9x6.7) 1 6 -12 (152 -305) Model G /F1 /EC4 Model G /F1 /HSW1 Re cessed Sidewal I Sprinkler Approval Type: Extended Coverage -Light Hazard Occupancy. Approvals: Underwriters Laboratories Inc. NYC BS&A No 587 -75 -SA Underwriters' Laboratories of Canada Installation Wrench: Model D Sprinkler Wrench. Color Identification: Black Paint (Bronze Finish Only). Ceiling to Deflector Distance: 6 to 12 inches (152mm to 305mm). Approval Type: Extended Coverage -Light Hazard Occupancy. Approvals: Underwriters Laboratories Inc. NYC BS&A No 587 -75 -SA Underwriters' Laboratories of Canada Installation Wrench: Model GFR1 Sprinkler Wrench. Color Identification: Black Paint (Bronze Finish Only). 2. MODEL G HORIZONTAL SIDEWALL SPRINKLER — HSW1 Deflector a '' 3 , `may,• , -fit Technical Data Installation Wrench: Model D Sprinkler Wrench. Ceiling to deflector distance: 4 to 6 Inches (102mm to 152mm). Nominal K Factor K Factor Sprinkler Approval Organizations Sprinklerldentification U.S. Metric Light Hazard Ordinary Hazard Orifice Thread Size Length Number(SIN) ' /z" (15mm) Yz" NPT (R' /z) 5.62 81.0 3 %6' (84mm) 1, 2, 3, 5, 6 1, 3, 5, 6 R1235 (11mm) 1/2" NPT (1`11/2) 4.24 61.0 3�46' (84mm) 1, 3, 5, 6 — R1233 (10mm) 1/i" NPT (RI/2) 2.82 40.6 3j6' (84mm) 1.3.5.6 — R1231 " /32" (20mm) 3/4" NPT (R3/4) 8.20 118.2 3�j6' (84mm) 1, 3, 5, 6 — R1237 " /g'"' (20mm) 1 1 /z° NPT(R1/2) 7.96 114.7 3 %s' (84mm) 1.3.5.6 — R1236 Identified by ointle extendina bevond dPflPrtnr Model G /F1 /HSW1 Recessed Horizontal Sidewall Sprinkler — HSW1 Deflector Technical Data Rating: 135 °F (57 °C) Max. Ambient Temp.: 100 °F (38 °C) Length: 3N6 ' (84mm) Approval Type: Light Hazard Occu pancy "" Identfied by pintle beyond deflector. MODEL G VERTICAL SIDEWALL SPRINKLER i h, Technical Data Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Ceiling to Deflector Distance: 4 to 6 inches (102mm to 152mm). Wall to Deflector Distance: 4 to 6 inches (102mm to 150 mm). Approvals: Underwriters Laboratories Inc. NYC BS &A No. 587 -75 -SA Underwriters' Laboratories of Canada Installation Wrench: Model GFR1 Sprinkler Wrench Color Identification: Black Paint (Bronze Finish only). Ceiling to Deflector Distance: 4 to 6 inches (102mm to 152mm). Nominal Orifice K Factor Sprinkler j Nominal Thread i Identification Orifice Size U.S Metric Number SIN YF (15mm) %" NPT (R1/2) 5.62 81.0 R1235 ' ' /s' "' 11mm V2° NPT R1 /z I 4.24 61.0 R1233 "" Identfied by pintle beyond deflector. MODEL G VERTICAL SIDEWALL SPRINKLER i h, Technical Data Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Ceiling to Deflector Distance: 4 to 6 inches (102mm to 152mm). Wall to Deflector Distance: 4 to 6 inches (102mm to 150 mm). Approvals: Underwriters Laboratories Inc. NYC BS &A No. 587 -75 -SA Underwriters' Laboratories of Canada Installation Wrench: Model GFR1 Sprinkler Wrench Color Identification: Black Paint (Bronze Finish only). Ceiling to Deflector Distance: 4 to 6 inches (102mm to 152mm). Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Approval Identification Organizations Number (SIN) U.S. Metric 15mm %' (R 112) 5.62 1 81.0 2' /e" (73mm) 2,4 R1285 3. Temperature ratings and finishes for Model G Horizontal Sidewall- HSW1 Deflector and Vertical Sidewall Sprinklers ` Frame color does not apply to plated or painted sprinklers. Finishes "' Approval Organizations: 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Corp. 3. Underwriters' Laboratories of Canada 4. LPCB 5. NYC BS &A No. 587 -75 -SA 6. NYC MEA 258 -93 -E Standard Finishes Maximum Escutcheon !Bronze Ambient Chrome Plated S rinkler Temperature Frame* Color °F °C °F °C 135 57 100 38 Black 165 74 100 38 Uncolored 212 100 150 66 White 286 141 225 107 Blue ` Frame color does not apply to plated or painted sprinklers. Finishes "' Approval Organizations: 1. Underwriters Laboratories, Inc. 2. Factory Mutual Research Corp. 3. Underwriters' Laboratories of Canada 4. LPCB 5. NYC BS &A No. 587 -75 -SA 6. NYC MEA 258 -93 -E Standard Finishes Sprinkler Escutcheon !Bronze Bronze Chrome Plated Chrome Plated Special Application Finishes Sprinkler Escutcheon Bright Brass m Bright Brass Black Plated Black Plated Satin Chrome Satin Chrome Lead Plated - 165 °F (74 °C), 212 °F (100 °C) and 286 °F (141 °C) Ratings Wax Coated - 165 °F (74 °C) Clear Wax, 212°F (100 °C) Brown Wax "' Wax Over Lead Plated - 165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax "' (')Other colors and finishes are available. Consult factory for details. (2) Only frame, deflector and cap are plated. (3) 212 °F (100 °C) brown wax may be used on 286 °F (141 °C) sprinklers when maximum ceiling temperatures do not exceed 150 °F (66 1C). UL Listed only. Ordering Information: Specify: 1. Model G or G /F1 2. Recessed (Only G /F1) 3. Deflector • Vertical Sidewall Deflector • Horizontal Sidewall - HSW1 Deflector • Horizontal Sidewall - EC4 Deflector 4. Nominal Orifice 5. Inlet Thread 6. Temperature Rating 7. Sprinkler Finish 8. Escutcheon Finish NOTE: Sprinkler and escutcheon are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. 0 (914) 668 -3470 Corporate Offices e''ab,Rim(914) (914) 592 -1414 Sales Offices 592 -3676 Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in USA 12/00 P/N 999997007