Loading...
HomeMy WebLinkAbout2660 Jewett Ln 08-2011t CITY OF SANFORD PERMIT APPLICATION Application # : U0 "' 1 1 Submittal Date: Job Address: Z kn O 7lvv11 ='Tr LAM-= Value of Work: S -�? 0 3 • 00 Parcel ID: 26 - % 9",30 -SAE- -7000 - 0000 Zoning: Historic District: Description of Work: - T:�JSTALL iGl,/Z ALAkM �NJX715M Square Footage: ......................................................................................... ............................... Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler /Alarm `o Pool ❑ Sign ❑ Electrical: New Service - # of AMPS Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑ Mechanical: Residential ❑ Non - Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair- Residential ❑ Commercial ❑ Occupancy Type: Residential ❑ Commercial 1)4 Industrial ❑ Construction Type: # of Stories: # of Dwelling Units: Property Owner: P1 too n i Address: 99 0 Wood CO ' V- 6AL/4nl bO , rL 02- $D 3 Phone3Z Bonding Company: Address: Architect/Engineer: Address Plan Review Contact Person: 7U A /i Occupancy Use Group(s): Flood Zone: (FEMA form required) ... .�. n_ ... ................... �1 J Q)q Contractor: to t2✓ Address: 3160 SCJU7 h,9 a4e MaE&0 -C 139 O�G4M y F& 220,16 Phone :X7Q 7- 712-14 State License Number: f000 0 Y,56 Mortgage Lender: Address: Phone: ' 7 1Z- Fax: - %�2 i$l. -mail: l C 0 r �@ Q� ' com Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the prope fthe requiren of Flo 'cla Lien Law, S713. Signature of Owner /Agent Date Signature of Contractor /Agent Date �j , &id [AS 0Jil A Q- Print Owner /Agent's Name Print Contracto ent's Name Signature of Notary-State of Florida Date Signature of No -State of Florida Date Notary Public State of Florida Nancy E Gibson My Commission DD510591 Expires 03/28/2010 Owner /Agent is _ Personally Known to Me or Contractor /Agent is _ Personally Known to Me or Produced ID Produced ID APPROVALS: ZONING: Special Conditions: Rev 07.07 UTIL: FD: ENG: BLDG: 1� � % J tyro ADT Security Services Inc Fire & 3160 Southgate Commerce Blvd Security Suite 38 � Orlando, FL 32806 s t Tele: 407- 712 -1620 Fax: 407- 712 -1813 LMTED POWER OF ATTORNEY I hereby name and appoint William McMahon, Nancy Gibson or Pablo Vera of ADT Security Services to be my lawful attorney in fact and apply To for a fire alarm permit for work to be performed at the following location: 2660 Jewett Lane Job address TI Automotive Group Project Name Sanford And to sign my name and do all things necessary to this appointment. Donald McConnell, Certified Contractor, License# EF0000950 State of Florida, County of Orange Personally known to me and acknowledged: Sworn to and subscribed before me this 284-11 day of Notary Public, SKte of Florida. J vi✓ A.D. 200 AY A Notary public State of Florida Nancy E Gibson .o� Niv Commission DD590591 My Commission Expires: Iar_ THIS RIDER made this and is to be attached to Agreement made the 6 RIDER For Additional Service day of June 2008 , is part of day of December 2006 by and between ADT Security Systems, ADT SECURITY SERVICES, INC. hereinafter called "ADT", and TI Automotive hereinafter called "Customer", for service In the premises of the Customer at 2660 Jewett lane Fire Alarm In the City of Sanford , State of The Customer hereby requests, and ADT agrees, to Install the following additional protection: This rider and the equipment installation are subject to the approval of the Authority Having Jurisdiction 1 SK -5808 Addressable Fire Alarm Control Panel 1 SK-5860 Remote Annunciator 2 Battery 12V 17.2AH 1 I SK- SD500PS Pull Station 1 SK- SD50SAPS Addressable Smoke Head 1 SK- SD5056AB Base 1 Key Lock Box 8 SK- SD500MIM Mini Contact Module Connection to existing ADT Sewrfty Services protection as now installed 1 AutoCAD PE Stamp & Permit The Customer hereby agrees to pay ADT, its Agents or Assigns, the sum of FL 3277E Two Thousand thirty nine ($ 2039.00 ) payable upon signing of this Agreement and the balance payable upon completion of the installation, and to pay in addition the additional sum of Three hundred forty eight and 481100 ($ 348.48 j per annum payable In advance. The parties hereto mutually agree that the aforesaid Agreement, of which this Rider Is made a part, is and shall be and remain in full force and off ect in accordance with all the terms and conditions thereof, modified only as 16 this Rider specifically provided. It is further agreed to that the original expiration date of the referenced Agreement shall be extended for a period of Five years. This Rider is not binding unless approved In writing by an authorized representative of the Company described above as ADT. ADT Security Services, Inc. - ADT By Agent APPROVED ` uU�gri�ed epresantative DT TI Automotive Cusiorrrer By rr!.n f ! C��' Ferry �J r� pwT ✓r'1 sd-,✓ A— c7 �' f3� Title CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407 - 302 -1091 * FAX #: 407 - 330 -5677 DATE: � l - PERMIT #: BUSINESS NAME/ PROJECT: i l/7i ti✓YItJTi'�/°L. C.L�D u� ADDRESS:Glrs PHONE NO.: 46%-- 7 %2 -1& 8 Z FAX NO.: Vv?- '7/2 -/ 8 I3 CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEW F. A. [ ] F. S. [ ] HOOD [ ] PAINT BOOTH [ ] BURN PERMI [ ] TENT PERMIT [ ] TANK PERMIT [ ] OTHER [ ] TOTAL FEES: S (PER UNIT SEE BELOW) COMMENTS: Address / Bldg. # / Unit # Square Footage Fees per Bldg. / Unit 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, Fl. 32771 Phone # -407- 330 -5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. a, . Sanfo ire Pre ention Division Applicant's Signature tyoo Fire & Security ADT June 24, 2008 Tim Robles Sanford Fire Dept. 1303 S. French Ave. Sanford, Florida 32771 RE: TI Automotive Group ADT Security Services Inc. 3160 Southgate Commerce Blvd Suite 38 Orlando, FL 32806 Tele: 407 - 712 -7620 Fax: 407 - 712 -1810 www.aclt.com EF 0000 949 2660 Jewett Lane Sanford ADT requests approval to install a fire alarm system at the above location per our plans and cut sheets. ADT will also install a lock box. The system will have remote station monitoring by ADT's UL Central Station. Please refer to the drawing for device location(s). Please contact me at (407) 712 -1682 with any questions. Sincerely, O n Cortes IntelliKnight® 5808 Single w Loop Addressable Fire /alarm Control System "a The convenience of an addressable fire alarm control panel in a cost- effective easy to use package. IntelliKnight Model 5808 is a 127 point class leading single loop (-''�- , f : '�„ addressable fire alarm control /communicator system. 5808 provides you !';� with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763- 493 -6435. Description 5808 performs drift compensation and calibration checks on each of the sensors in the system. The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial /parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5808 also features a powerful built -in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Up to 127 addressable points • Up to 125 zones and 125 output groups • Uses standard wire —no shielded or twisted pair required • Built -in digital communicator • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Distributed, intelligent power • Drift compensation • 13 pre - programmed output cadences, (including ANSI - 3.41), and 4 programmable outputs • Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder -power • Built -in annunciator with 80- character LCD display • RS -485 bus provides communication to system accessories • Built -in RS -232 and USB interface for programming via a PC • Upload or download programming, event history, or detector status via remote or direct connection • Improvements in SKSS deliver five times faster upload /downloads Built -in synchronization for appliances from AMSECO, Gentex@), Faraday, System Sensor@), and Wheelock® One Form C trouble relay rated at 2.5A at 27.4 VDC and two Form C programmable relays rated at 2.5A at 27.4 VDC Programmable date setting for Daylight Saving Time Plex -2 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Electrical Specifications Primary AC: 120 VRMS at 50/60 Hz, 2.75A Total Accessory Load: 6A @ 27.4 VDC Notification Power: 6A @ 27.4 VDC, power - limited Standby Current: 170 mA Alarm Current: 325 mA Notification & Auxiliary Circuits: 3A @ 27.4 VDC per circuit, power - limited Battery Charging Capacity: 7.0 -35.0 AH Battery Size: 18 AH max. allowed in FACP. Larger capacity batteries can be housed in an RBB accessory cabinet Mechanical Specifications Flush Mount Dimensions: 14.5" W x 24.75" H x3.5 "D (36.8 W x 62.9 H x 8.73 D cm) Overall Dimensions: 16 "Wx26.4 "Hx4.65 "D (40.6 W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Telephone Requirements: Model 5808 FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non - coded) signalling services. Other Approvals: UL- Listed; CSFM 7170 -0559: 142; MEA 429 -92 -E Vol. XIV SILENT KNIGHT by Honeywell 5860 Demote Annunciator - -- Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. z1: rte. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator Wit. -i 4 { g provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built -in annunciator. The 80- character display and ergonomically designed keypad allow for simple and error -free system operation. All operations — including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS -485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1 -800- 446 -6444, or in Minnesota, call 763- 493 -6435. Description Features include an 80- character backlit LCD providing easy -to- understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. • Available in red or light gray • Support for simultaneous use of multiple 5860s • RS-485 interface to panel • Operation and appearance is identical to 5860 built -in annunciator • On -board piezo sounder audibly indicates alarms, troubles, and supervisories • Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions • Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) • UL listed, complies with NFPA 72 • CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Features Alarm Current: 25 mA • 80- character backlit LCD display Wiring Distance: 6,000 max. from (4 lines with 20 characters on FACP (depending on wire gauge each line) ----- -and number: of devices on .the . . • Tactile and audible feedback SBUS) • Accepts user codes or fire fighter's key Max Per System: 8 • Larger keypad buttons for system Mechanical Specifications reset and silence Physical 9.1" W x 7.4" H x 1.5" D • Install up to eight 5860s per (23.1 W x 18.8 H x 3.8 D cm) FACP Shipping Weight: 2.8 Ibs (1.3 kg) —7 5860 Color 5680R: Red 5680: Gray Environmental Operating Temperature: 32 °F – 120 °F (0 °C – 49 °C) Humidity: 10% – 93% non - condensing Approvals NFPA 72; UL Listed; CSFM 7170 -0559: 135; MEA 429 -92 -E Vol: "IX; FM Approved SILENT }n� KNIGHT by Honeyv ell 5860 Remote Annunciator Engineering Specifications The main control must have a built -in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built -in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built -in annunciator. All annunciators must have an 80- character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. -3 seuS t�s ryY.��y Compatible Intelfiitnight FACP Compatibility IntelliKnight 5820XL FACP IntelliKnight 5808 FACP IntelliKnight 5700 FACP SILENT I <NIGHT 14 by Honeywell Wire Runs Up to 6000 Feet From FACP 5860 5860 Up to Eight 5860s Per System Ordering Information 5680R Remote Annunciator Four line LCD annunciator with 20 characters per line. Red. 5680 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring For surface mounting. 586OTG Gray Trim Ring For surface mounting. This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maole Grove, MN 55369 -4927. Phone: (800) 328 -0103, Fax: (763) 493 -6475. 5060 - MADE IN AMERICA FORM# 350224 Rev C, 05 /06 Copyright © 2006 Silent Knight SD500 -PS and SD500 -PSDA Addressable Pull - Station Intellil(night's addressable pull stations combine fast response with pin -point location ID. The SD500 -PS and SD500 -PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500 -PS /PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500 -PS /PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500 -PSDA► Addressable Pull Station The SD500 -PS is a single action addressable fire pull station, and the SD500 - -PSDA is a dual action addressable fire pull station. The SD500 -PS /PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an IntelliKnight control panel. The SD500 -PS /PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold - plated to avoid risk of corrosion. The SD500- PS /PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features • UL Listed • CSFM listed • ADA compliant • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available • Terminals - accept up to 14 gauge wire • Corrosion - resistant gold - plated contacts. • Reflective label makes it easier to locate in low light Operation The SD500 -PS /PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500 -PS /PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the -loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 24VDC Standby Current: .55mA Alarm Current: .55mA SD500 -PS Ambient Temperature: 32 °F to 120°F Mounting: Single gang box - Optional Red Surface Mount Box PS -SMBB vmo� r ILEN I R� 11A .. D 5 0 0 P , -y and ?,> st i'i 0 ,. j)♦t S 5,'A Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500- PS /SD500 -PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. rcF T t\ t Wiring z,1:<-.• Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box I �C SD500 -PSDA .:. I lerlrmal uc., nPXI 7P Installing SQ500 -L1C at r.m-1- 1it'":;' Dimensions SILENT K IGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800- 446 -6444 or in Minnesota 763- 493 -6435 FORM# 350342, Rev. 09/03 FAX: 763-493-6475 World wide web: http: / /www.silentknight.com Copyright © 2003 Silent Knight Addressable T E Photc, ectric Type 1 Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnightO photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal - resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -APS Analog / Addressable Photoelectric Type Smoke Detector The SD505 -APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTm based downloading software). Operation The SD505 -APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives .no light _ from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features • Low profile, 2 inches, including base • Simple and reliable addressing without mechanical switches • Automatic compensation for sensor contamination • Built -in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer software. Vandal- resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved �%a,,� l J SD505 -APS Smoke Detector Specifications Operating Voltage: 17 -41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32 °F to 120 °F (0 °C to 49 °C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: .., '0 - 300 FPfvt ._:.. � . .... ...:.... Compatible Bases: SD505 -6AB (Sold Separately) (6° Base) SD505 -4AB (4" Base) SILENT KNIGIIT by Honeywell Model D50 - PS Addressable Photoelectric Type Smoke Detect ®r r.F xn,r_,�r Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD5O5 -APS. The combination detector head, and twist -fock base, shall be ULO listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD5O5 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal - resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. __.- .u:...�:.u..a:ac:..:..�. ,.:- rernx..v.r�:,,,- .nv.:: �c�.:r �rur <- m » <rb+a: <,a;�xrzm- s::.x.:.�s ra. ::m.rrf:�. - ;.srs� ». ,�- •..:nr..�,..y..,e�:s.�.. }.....c,.ti�. ...�,..�,,�e i...o4<. a..a...r .:.:�ax::,cr�_:ic D . weter 3-15116" �SILLVl � . A \i(,l Tr Model SD505 -6AB Detector Base (front view) Height = 2 inches, including base Model SD505 -APS Detector Head (front view) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05105 0 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. X "s �. . a=h"s'' ra fi -t. ,, r ,s"'r a, �,za°� ��i�'°'•'-'* Y ,,.r SD500 -AIM & S® -500-MIM ;v Addressable Input Modules Sq IntelliKnightas addressable contact monitor modules combine fast response with pinpoint location I®. A combination that saves lives and property. The SD500 -AIM and SD500 -MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500 -AIM and SD500 -MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500 -AIM and SD500 -MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation —a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 -446 -6444, or in Minnesota, call 763 -493 -6435. Description The SD500 -AIM and SD500 -MIM are addressable input modules for use with the Intelliknight fire alarm control panels (FACPs). The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow Switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACR Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features • Single contact monitor • Up to 2500 ft wiring distance from either input module to contact • Use up to 14 gauge wire • UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 50f) max Mechanical Specifications SD500 -AIM Physical Description Dimensions: 4.9" W x 4.9" H x 1" D (12.4Wx 12.4 H x 2.5 D cm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500 -MIM Physical Description Dimensions: 1.5" W x 2.5" H x 0.7" D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) • Support for Class.A (Style 6 & Style Environmental 7) or Class B (Style 4' ) wiring Operating Temperature: • Attractive ivory cover plate with the 32 °F – 120 °F (0 °C – 49 °C) SD500 -AIM • Small and lightweight size allows for Humidity: o 10% – 93% non - condensing flexible mounting options with the SD500 -MIM • DIP switch programmable for fast installation F_ SD500 -AIM SD500 -MIM Approvals NFPA 71 & NFPA 72 UL 864 CSFM 7300-0559:132 MEA 429 -92 -E Vol. IX FM Approved for use with the 5820XL 13 SILENT KNIGHT by Honeywell S 500-AIM & SD500- IM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500 -AIM or SD500 -MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500 -MIM shall fit inside a single gang electrical box. The SD500 -AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4 "- square or double gang electrical box. The SD500 -AIM addressable input module must provide a monitor LED that is visible from outside the cover plate tC M ItC N I Compatibility IntelliKnight 5820 FACP !ntelliKnight 5808 FRCP IntelliKnight 5700 FACP Ordering Information SD500 -AIM Input Module Addressable input module with ivory cover plate. SD500 -MIM Mini Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up -to -late and accurate. We cannot cover all [3 specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Phone: (800) 328 -0103, Fax: (763) 493 -6475. MADE IN AMERICA FORM# 350231 Rev.C, 05/06 Copyright © 2006 Silent Knight %, crnlac: Na: �r l.m�CC:I ��— To correct Compatibility IntelliKnight 5820 FACP !ntelliKnight 5808 FRCP IntelliKnight 5700 FACP Ordering Information SD500 -AIM Input Module Addressable input module with ivory cover plate. SD500 -MIM Mini Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up -to -late and accurate. We cannot cover all [3 specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Phone: (800) 328 -0103, Fax: (763) 493 -6475. MADE IN AMERICA FORM# 350231 Rev.C, 05/06 Copyright © 2006 Silent Knight SECTION 2 FIRE ALARM CABLE 33.0 ADT 494480 PART NUMBER 2C 12 AWG �NUUCTOg S I SHIELDED OVERALL JACKET VOLTAGE TYPE FPLR/ CL3R UL TEMP PUT UNSHIELDED DIAMETER RATING (16sullnit 300, 9.0 UPS 60 °C NON-PLENUM, NO SHIELD LIGHT BLUE LBS 22 AWG • REEL YELLOW TYPE CIVIRI FPLR (UL) ul ADT SCNF 2 UNSHIELDED .140" LIGHT BLUE WHITE 30N 8.0 ADT493494 2/C 75 °C 500 7 493494 CONDUCTOR YELLOW LBS 18 AWG TYPE GIVIRI -BOX FPLR JUL) (GSA) PAIGE PNI TYPE CMG 740135 75'C ADT SCNI 4 BLACK, RED, RED 15.0 PAIGE ELECTRIC 60 °C CONDUCTOR WHITE, GREEN LBS PART NO. 454704ARE 18 AWG TYPE FPLR PAIGE PNI (UL) ul ADT SCNI 2 .175" BLACK, RED 12.0 16 AWG 21C (UL) 500 740206-L CONDUCTOR LBS TYPE FPLR SUN REEL RES - C(UL) PAIGE PNI CMG UL 454731ARE ADT GNI 2 .225" 16 AWG WHITE 36.0 ADT 493497 493497 PAIR BLACK/ RED, LBS I PR 16 AWG 19 AWG I PR 19 AWG TYPE FPLR/ UL PAIGE PNI LIGHT BLUE! CIAR (UL) 740028 YELLOW ADTSCN# 4 ADT 494465 494465 21C 16 AWG CONDUCTOR 2/C 19 AING TYPE FPLR/ ul PAIGE PNI CMR JUL) 740026 ADT S CN 1 4 UNSHIELDED .265" 14 AWG WHITE 300v 50.0 ADT 494479 21C 60 °C 500 -z 494479 CONDUCTOR BLACK/ RED, LBS 14 AWG 21C 18 AWG REEL -Z-f' 16 AWG TYPE FPLR/ CL3R UL PAIGE PNI LIGHT BLUE 740027 YELLOW (UL) ADTSGNI 740203 paiRr r. [�Z 2 CONDUCTOR .230" BLACK, RED RED LBS 2C 14AWG (UL) FPLR n� WHITE 20.0 1 ADT 494478 75 °C LBS 2C 14 AWG TYPE FPL,,J CL3R ul (UL) (CSA) BLACK,RED, RED 35.0 fFPLR/CL3R BROWN, BLUE LBS 14 AWG (UL) ul BLACK.REO WHITE 33.0 ADT 494480 LBS 2C 12 AWG TYPE FPLR/ CL3R UL (UL) (GSA) BLACK / RED. WHITE 300, 9.0 ADT 494475 2 PAIR 60 °C 500 LIGHT BLUE LBS 22 AWG REEL YELLOW TYPE CIVIRI FPLR (UL) ul BLACK.RED I RED 1 1 8.0 1 FPLR/CMRlIAWG 75 °C 1. ] LBS .(UL) C (f UL), CMG BOX UL 10.0 1 (IL)TYIEFPLR 60 °C 500 LBS 14 AWG REEL UL IUI UWtWaAaWMWWAVjN a L eaaACICIbattenes FEATURES r Sealed/Maintenance -Free The valve regulated, spill -prof construction of the Power -Sonic battery allows trouble-free, safe operation in any position. There is no need to add elecrolyte, as gases generated during over- charge are recombined in a unique "oxygen cycle." Easy Handling No special handling precautions or shipping containers — surface or air — are required due to leak-proof construction. Economical The high watt-hour per dollar value is made possible by the materials used in a sealed lead -acid battery: they are readily avaaable and low in cost Long Service Life Under normal operating conditions, four or five years of depend- able service life can be expected in stand -by applications, or between 200 and 1000 charge/ discharge cycles depending on the average depth of discharge. Design Flexibility Batteries may be used in series and/or parallel to obtain choice of voltage and capacity. Due to recent design breakthroughs, the same battery may be. used in either cyclic. or standby appfi -.. _ cations. Over 40 models are available to choose from. Rugged Construction The high impact resistant battery case is made either of non- conductive ABS plastic or styrene. Large capacity batteries fre- quently have polypropylene cases. All of these materials impart great resistance to shock, vibration, chemicals and heat Compact Power -Sonic batteries use state -of - -the -art design, high grade materials, and a carefully controlled plate - making process to provide excellent output per cell. The high energy density results in superior power/volume and power/weight ratios. High Discharge Rate Low internal resistance allows discharge currents of up to ten tines the rated capacity of the battery. Relatively small batteries may thus be specified in applications requiring high peak currents. Long Sheff Life A low self- discharge rate permits storage of fully charged batteries for up to a year at room temperature before charging is required. Lower storage temperatures enhance shelf life characteristics even further. Wide Operating Temperature Range Power-Sonic batteries may be discharged over a temperature range of -20'C to +60'C (4 F to +140'F) and charged at temperatures ranging from -20'C to +50'C (-4'F to +122 °F). Deep Discharge Recovery Special separators, advanced plate composition, and a carefully balanced electrolyte system have greatly improved the ability of recovering from excessively deep discharge.