Loading...
HomeMy WebLinkAbout165 Towne Center Cir 08-2045CIYY OF 0141151-0 Application # leg ' Zd 5 Job Address: Parcel Ill' Rp PERMIT APPL.IOA7iON JUN 2 7 2008 Toning: Submittal Date: Value of Work: $(S Historic District: Description of Work: l& °a���� G� f Square Footage: .... ........................ ............................... .......... Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing E7 1 in Sprinkler /Alarm # Pool ❑ Sign ❑ Electrical: New Service – # of AMPS –_ Addition /Alteration s Change of Service ❑ Temporary Pole ❑ Mechanical: Residential ❑ Non - Residential ❑ Replacement ❑ New ❑ (Duct layout & Energy Cale. Required) Plumbing/ New Commercial: i/ of Fixtures , # of Water & Sewer Lines_„ # of Gas Lines ,_ Plumbing/New Residential: #/ of Water Closets Plumbing Repair – Residential ❑ Commercial 0 occupancy Type: Residential ❑ Commercials, Industrial ❑ Occupancy Use Group(s): Construction 'Type: # of Stories:. #/ of Dwelling Units: Flood Zone: _„__ (FEMA form required ) ......... Property Owner: Contractor: Si rnPi C�n�n�i,e a � , / Address: Address: ��� U 1 %1 1 Ah n 7d ti'^' L Phone: E -mail: Phone' Jf ate License Number: Zc3ii�D��3 Bonding Company: Address: Architect/Engineer:i Address: Plan Review Contact Person: Mortgage Lender: Address: Phone: Fax: __. Phone: Fax: E -mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. t understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, aid AIR CONDITIONERS, etc. OWN1;R'S AFFIDAVIT: I certify that all of the foregoing infottttvion is accurate and that all work will be done in compiiance with all applicable laws regulating construction and ;coning. WARNING TO OWNER: YOUR FAILURE'- TO RECORD A NOTICE OF COMMENC@MENT MAY RESULT iN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON 'ri-w JOB SITE BITORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LEND &R OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE 017 COMMENCEMENT. K0�17CE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that maybe found in the public records of Ibis county. and there may be additional pemtits required from other governmental entities such as water management districts. state agencies, or federal agencies. Acceptance of pennil is verification that I will notify ilic owner ofthc property of ths;regairentcnts d» l ice.arv: l'S 713. ire—of Owner /Agent – Date Signature of Contractor /Agent Dat Print Owner /Agent's Signature ofNotnsy -State ofFlorida Date O +%ncr /Agent is__ Personally Known to Me or _ Produced ID .— __._ APPROVALS: 7-ONING:.- ., -... —. _.....- U'1'i1.: _.- ..._____ 1'D: Special Conditions: Rev 07.07 Pri Convactor /Agent's i`'ame %% 7. A�.ae On.i��1) iv 427 ar-Stf itc of Florida Date _ SIJSE.X; *E ANIfii A Jtti� I NOTARY PUBLIC — STATE OF FLORIDA COMMISSION #DD477401 2009 ..� nbannotcsltllaFXP.1RES.Q�,T. 2, Two Fire & Security 3701 North John Young Parkway Suite 110 Orlando, FL 32804 SimplexGrinnell (407) 235-1100 Phone (407) 235 -1150 Fax POWER OF ATTORNEY MAY 15, 2006 I HEREBY AUTHORIZE JOSEPH J. NEMCEK & RYAN FUNK OF SIMPLEX GRINNELL TO SIGN FOR, APPLY FOR AND PICK -UP FIRE SUPPRESSION PERMITS IN THE STATE OF FLORIDA �_uL 'b"" - 6- tkg- -_ r _'_ �_ GEORGE ILLER BEFORE ME APPEARED GEORGE E MILLER TO ME WELL KNOWN TO ME TO BE THE PERSON DESCRIBED IN AND WHO EXECUTED THAT GEORGE E MILLER EXECUTED SAID INSTRUMENT FOR THE PURPOSES THEREIN EXPRESSED. WITNESS MY HAND AND OFFICIAL SEAL, THIS 16 DAY OF MAY NOTARY PUBLIC STATE OF FLORIDA PAMELA A . MCELROY Notary Public, State 0I T Florida c My comm. exp. Comm. No. DD 411$91 CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407 - 302 -1091 * FAX #: 407 - 330 -5677 DATE: -7 /1 /a PERMIT #: BUSINESS NAME / PROJECT: ADDRESS: [ (a S (O JYJ d--2, 1,UZ • Gt rL, PHONE NO.: t(o7— -23,5:-110-0 FAX NO.: CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEWz F. A. [ ] F. S. [ ] HOOD [ ] PAINT BOOTH [ ] BURN PERMIT—r] TENT PERMIT [ ] TANK PERMIT [ ] OTHER [ ] TOTAL FEES: $ %.5 0� COMMENTS: Address / Bldg. # / Unit # 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. (PER UNIT SEE BELOW) Square Footage Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, Fl. 32771 Phone # -407- 330 -5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. (./ Sanfor re Prev tion Division Applicant's Signature tqCJ2 Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -FRB — 2.8, 4.2, 5.6, and &0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tycom Series TY -FRB, 2,8, 4.2, 5.6, and 8.0 K- factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY -FR13 Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two -piece Style 10 (1/2 inch NPT) or Style 40 (314 inch NPT) Recessed Es- cutcheon with 112 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two -piece Style 20 (1/2 inch NPT) or Style 30 (314 inch NPT) Recessed Escutcheon with 114 inch (6,4 mm) of recessed adjust- ment or up to 112 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas /chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY -FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY -FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair file performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. AUGUST, 2007 F. Upright 2.81K, 112 "NPT TY1231 - ,f TY2131 - Fi= TY2231 - Pendent 4.21K, 112 "NPT TY3131 - Upright 5.61K, 112 "NPT TY3231 - Pendent 6.61K, 112 "NPT ModeUSprinkler Identification Numbers TY1131 - Upright 2.81K, 112 "NPT TY1231 - Pendent 2.81K, 112 "NPT TY2131 - Upright 4.21K, 112 "NPT TY2231 - Pendent 4.21K, 112 "NPT TY3131 - Upright 5.61K, 112 "NPT TY3231 - Pendent 6.61K, 112 "NPT TY4131 - Upright 8.0K, 314 "NPT TY4231 - Pendent 8.01K, 314 "NPT TY4831- Upright 8.0K, 112 "NPT TY4931- Pendent 8.OK, 112 "NPT TFP171 TF'P171 ESCUTCHEON PLATE SEATING SURFACE 2- 3116" (55,6 mm) 112" NPT 7116" (11,1 mm) NOMINAL MAKE -IN STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR 7116" (11,1 mm) NOMINAL MAKE-IN 2 -3116" WRENCH — _ _ (55,6 mm) FLATS 112" NPT SSP DEFLECTOR * ��M- 2 -718" (73,0 mm) DIA. PENDENT Page 3 of 10 (�r 1S RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3. Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 112 INCH NPT ESCUTCHEON 112" (12,7 mm) PLATE SEATING NOMINAL SURFACE NPT MAKE -IN 2- 5116" - �- (58,7 mm) .I . 1 -9116" (39,7 mm) STYLE 30 or 40 RECESSED SSU" ESCUTCHEON DEFLECTOR I WRENCH FLATS SSP DEFLECTOR * - -' 2.718" (73,0 mm) DIA. - -I PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Butlon Assembly 5 - Compression Screw 3/4" NPT UPRIGHT 112" (12,7 Iron) NOMINAL MAKE -IN 2 -114" t (57,2 mm) 1� CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 314 INCH NPT Page 4 of 10 TFP171 7/16" (11,1 mm) NOMINAL SSU' 112 MAKE -IN DEFLECTOR NP7 l 2-3/16" 5 2 -114" (55,6 mm) 4 (57,2 mm) 1- 9116" WRENCH 2 (39,7 mm} FLATS 3 — SSP* 1 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector a Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K- FACTOR, 112 INCH NPT Technical Data Approvals UL and C -UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM /psi112 (40,3 LPM /bar112) K = 4,2 GPM /psi1 /2 (60,5 LPM /bar112) K = 5.6 GPM /psil12 (80,6 LPM /bar112) I< = 8.0 GPM /psi1f2 (115.2 LPM /bar1/2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ... . ... .. .. Bronze Button . .. ... Brass /Copper Sealing Assembly ......... . .. Beryllium Nickel w /Teflont Bulb .... .... . ...... Glass Compression Screw .. .. Bronze Deflector . _ . Copper /Bronze Bushing (K =2.8) .. ..... Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY -FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Y IO E v P m .y Of 0 0. 7 D t Page 6 of 10 TFP171 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire 8 Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094x/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (314" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. " Installed with Style 20 (112" NPT) or Style 30 (3/4" NPT) 112" Total Adjustment Recessed Escutcheon, as applicable. - Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED WHITE '** POLYESTER LEAD COATED 135 °F /57 °C Orange PENDENT (TY3231) 1, 2, 3, 4, 5, 6, 7 1. 2, 3, 5 155°F/68 °C Red 175 °F /79 °C Yellow and UPRIGHT 200 °F /93 °C Green 5.6 (TY3131) 286 °F /141 °C Blue 1/2" NPT 135 °F /57 °C Orange RECESSED PENDENT 1, 2, 4, 5 NIA 155 °F /68 °C Red 175 °F /79 °C Yellow (TY3231)` 200 °F /93 °C Green Figure 10 135 °F /57 °C Orange 1, 2, 3, 4, 5 NIA RECESSED PENDENT 155 °F /68 °C Red 175 °F /79 °C Yellow (TY3231)" 200 °F /93 °C Green Figure 11 135 °F /57 °C Orange PENDENT (TY4231) and 1, 2, 3, 4, 5, 6, 7 1,2,5 155 °F /68 °C Red 175 °F /79 °C Yellow 200 °F /93 °C Green UPRIGHT 8.0 (TY4131) 286 °F1141 "C Blue 314" NPT 135 °F /57 °C Green RECESSED PENDENT 155*F /68 °C Orange 1, 2, 4, 5 NIA 175 °F /79 °C Red (TY4231)' 200 °FI93 °C Yellow Figure 12 135 °F /57 °C Orange RECESSED PENDENT 1, 2, 3, 4, 5 NIA 155'F /68 °C Red 175 °F /79 °C Yellow (TY4231)'* 200 °F /93 "C Green Figure 13 135 "F /57 °C Orange 8,0 112" PENDENT (TY4931) and 1, 2, 4, 5, 6 1, 2, 5 155 °F /68 "C Red 175°F/79 °C Yellow 200 °F /93 °C Green NPT UPRIGHT (TY4831) 286 °F /141 °C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire 8 Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094x/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (314" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. " Installed with Style 20 (112" NPT) or Style 30 (3/4" NPT) 112" Total Adjustment Recessed Escutcheon, as applicable. - Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS TFP171 Page 7 of 10 NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories. Inc. for use in Canada (C -UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY -FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1,6 mm) for the 135 "F /57 °C to 3132 inch (2,4 mm) for the 286 °F /141 °C temperature ratings. A leak tight 112 inch NPT sprinkler join t should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft, lbs. (28,5 Nm) of torque may be used to install sprinklers with 112 NPT connections. A leak tight 314 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Alm) of torque is to be used to install sprinklers with 314 NPT con- nections. Nigher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make -up for insufft- cient adjustment in the escutcheon plate by under- or over - tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY -FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W -Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY -FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over tile, sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W -Type 7 Recessed SPRINKLER FINISH K TYPE NATURAL BRASS CHROME PLATED WHITE POLYESTER LEAD COATED PENDENT (TY3231) 2.8 and UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 112" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) 4.2 and UPRIGHT (TY4131) 175 PSI (12,1 BAR) NIA 3/4" RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and r 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 1/2„ NPT UPRIGHT(TY3131) OR 175 PSI (12,1 BAR) (SEE NOTE 1) NIA RECESSED PENDENT (TY3231) PENDENT (TY4231) and �_ 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 80 UPRIGHT(TY4131) N/A 3/4" NPT RECESSED PENDENT (TY4231) 8.0 1/2" PENDENT (TY4931) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT(TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories. Inc. for use in Canada (C -UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY -FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1,6 mm) for the 135 "F /57 °C to 3132 inch (2,4 mm) for the 286 °F /141 °C temperature ratings. A leak tight 112 inch NPT sprinkler join t should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft, lbs. (28,5 Nm) of torque may be used to install sprinklers with 112 NPT connections. A leak tight 314 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Alm) of torque is to be used to install sprinklers with 314 NPT con- nections. Nigher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make -up for insufft- cient adjustment in the escutcheon plate by under- or over - tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY -FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W -Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY -FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over tile, sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W -Type 7 Recessed Page 8 of 10 _ 2 -718" DIA. 5/8 ±1/4" (73.0 mm) 3/4'(19,1 mm) _ (15,916,4 min) 2.1/4" DIA. —^ 114" (6.4 mm) FACE OF (57'2 mm) I MOUNTING SPRINKLER PLATE FITTING — -- _.) IV (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 rttm) TY -FRB 13/16' (20,6 mm) FIGURE 6 SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.6 K- FACTOR, 112 INCH NPT 2.718" DIA. 5181114" . - (73,0 mm) 314'(19,1 mm) (15,916,4 min) 2-1/4' DIA. 114"(6.4 mm) FACE OF (57'2 mm) I MOUNTING SPRINKLER _i PLATE FITTING 1I8" (3,2 nun) MOUNTING t SURFACE - - -- • -- CLOSURE SERIES 1- 1/4'(31,8mm) TY-FRB 3/4'(19,1 mm) FIGURE 8 SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K- FACTOR, 112 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been In- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY -FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY -FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve lot' maintenance TFP171 2 -7I8 "DIA. (73,0 mm) 1/2" (12,7 mm) 1121118" (12,71.3,2 milt) _ 2 -1/4 -DIA. � 114" (614 mm) FACE OF (57'2 mm) MOUNTING SPRINKLER �� PLATE FITTING 21M _...._. �_ (3.2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5110'(33,3 milt) TY -FRB 1 -1116' (27,0 mmt) FIGURE 7 SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8K-FACTOR, 112 INCH NPT - -- 2.7/8" DIA.. -,_ 1/2f118" (13,0 min) 112" (12,7 mm) _ (12,713,2 min) 2 -1/4" DIA. Y 1/4" (6,4 milt) FACE OF — (57,2 mm) MOUNTING SPRINKLER PLATE FITTING I I 118" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1 -1 /4" (31,8 milt) TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K- FACTOR, 112 INCH NPT work on the fire protection system that it controls, permission to shut down the affected fire protection system mustbe obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- 1(lers are not used for hanging of any objects; otherwise, non - operation in the event of fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler, operation i» a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist /slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the Installation has been com- TFP171 2 -7/8" DIA. — 5181114" (73,0 mm) 314 "(19,1 mm) (15,916,4 mm) 2 -1/4' DIA. 114" (6,4 mm) —�I FACE OF (57.2 ntm) MOUNTING SPRINKLER PLATE FITTING - -- - — (3,2 nim) 118„ t MOUNTING SURFACE CLOSURE SERIES 1 -1/4° (31,8 mm) TY -FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K- FACTOR, 112 INCH NPT I _ 2 -718" DIA. Ir (73,0 mm) 314' (19,1 mm) 5/811/4" 114'(6,4 min) (15,9-+0,4 mm) _ 2 -114" DIA. FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 118" (3,2 mnt) _t MOUNTING SURFACE _ CLOSURE SERIES 1 -5116" (33,3 mm) TY -FRB 13116" (20,6 mm) FIGURE 12 SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K- FACTOR, 314 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close -up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- Page 9 of 10 _ 2 -7/8' DIA. 1/21118" (73.0 mm) 112'(12,7 ntm) (12,713,2 mm) _ 2 -1/4' DIA. 1/4" (6,4 mm) — (57,2 mm) FACE OF MOUNTING SPRINKLER lam.— PLATE FITTING 1 /8" - -� - — (3,2 mm) MOUNTING SURFACE CLOSURE SERIES — 11-1/4" (31,8 mm) TY -FRB 1" (25,4 mm) FIGURE i 1 SERIES TY -FR8 RECESSED PENDENT WITH TWO -PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 112 INCH NPT 2 -7 /8" DIA. _.. (73,0 mm) 112'`(12,7 nron) 11211/8" (12,713,2 mm) _ 2 -114" DIA. 114"(6.4 mm) FACE- OF (57,2 mm) MOUNTING SPRINKLER I �% PLATE FITTING I 118" _ (3,2 min) MOUNTING SURFACE CLOSURE SERIES 1 X116" {33,3 mm)� TY -FRB 1.1/16" (27,0 mm) FIGURE 13 SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8,0 K- FACTOR, 314 INCH NPT WRENCH RECESS (END "A' USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W -TYPE 6 SPRINKLER WRENCH faclurer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS rl ., PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W -TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and /or national codes. Page 10 of 10 PIN 57 - XXX ) -X -XXX MODEUSIN 330 2.8K UPRIGHT (1/2 "NPT) TY1131 331 2.8K PENDENT (112 "NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 72K PENDENT (1/2 "NPT) TY2231 370 5.6K UPRIGHT (112 "NPT) TY3131 371 5.6K PENDENT (1/2 "NPT) TY3231 390 8.OK UPRIGHT (314 "NPT) TY4131 391 8.OK PENDENT (314 "NPT) TY4231 360 8.0K UPRIGHT (1/2 "NPT) TY4831' 361 8.OK PENDENT (1l2 "NPT) TY4931' Limited Warranty TFP171 Eastern Hemisphere sales only. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and /or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The �oreg!2ing warranty is made in-1 ±eu of any and all other warranties, ex- press or implied including warranties of merchantability and fitness for a par- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made In contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify ModelISIN), Quick Response, (specify K- factor), (specify temperature rating), Series TY -FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify') fin- ish, PIN (specify'). . Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, PIN 56 -000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, PIN 56- 850 -4 -001. TYCO FIRE & BUILDING PRODUCTS, 461 North Cannon Avenue, Lansdale, Pennsylvania 19446 SPRINKLER RATING 135 135 °F /57 "C 1 NATURAL BRASS 155 155 °F /68 °C 4 WHITE POLYESTER 175 175 °F /79 °C 3 WHITE (RAL9010)* 200 200 °F /93 °C 9 CHROME PLATED 286 286 °F /141 °C 7 LEAD COATED Eastern Hemisphere sales only. TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and /or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The �oreg!2ing warranty is made in-1 ±eu of any and all other warranties, ex- press or implied including warranties of merchantability and fitness for a par- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made In contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify ModelISIN), Quick Response, (specify K- factor), (specify temperature rating), Series TY -FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify') fin- ish, PIN (specify'). . Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, PIN 56 -000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, PIN 56- 850 -4 -001. TYCO FIRE & BUILDING PRODUCTS, 461 North Cannon Avenue, Lansdale, Pennsylvania 19446