HomeMy WebLinkAbout4004 Orlando Dr 08-130 (6 new fire sprnklrs)��, ) BLID pe&. nrr CITY OF SANFORD PERMIT APPLICATION�� r'�7 (9t{ Z Application 9: — ?jam Submittal Date: 1—Z—L7_ Job Address: ' t i t- c 'CoO,� 000,0 ,lue of Work: $ 1000,00 Parcel ID: Zoning: Historic District: Description of Work: ADD (� N C W FIRe 5 1N9LEi2_S Square Footage: ......................................................................................... ............................... Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler /Alarm 0 Pool ❑ Sign ❑ Electrical: New Service — # of AMPS Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑ Mechanical: Residential ❑ Non - Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair —Residential ❑ Commercial ❑ Occupancy Type: Residential ❑ Commercial 19 Industrial ❑ Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required ) Property Owner: Contractor: rOWELL FIRE 5 PRixgLc: g.5 5 `,57"91925 zS( Address: Address: 2_1( N, X EN r A,\10 OR( (F'L -325v5- Phone: E -mail: Phone:�ei ?793 State License Number: 5Q80G31ZUW Bonding Company: Mortgage Lender: N/q Address: Address: 14 n Architect/Engineer: ICI {4 Phone: Plq Address: /u Fax: 414 Plan Review Contact Person: Phone: Fax: E -mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. 7 /.cam I -2 -oe Signature of Owner /Agent Date Signature of Contractor /Agent Date LEE Po,Jc�_ Print Owner /Agent's Name Prints Contractor /Agent's N e O, ,, &-04, 7 t Signature of Notary-State of Florida Owner /Agent is _ Personally Known to Me or Produced ID APPROVALS: ZONING: Special Conditions: Rev 07.07 Date Signature of Notary-State rsonally npwp,to9vle or ( o —o i� /, r 1 tqC0 Fire & Building Products Technical Services: Tel: (800) 381 -93121 Fax: (800) 791 -5500 Series 7Y -FRB — 2.8, 4.2, 5.6, and &0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard coverage General Description The Tyco® Series TY -FRB, 2.8, 4.2, 5.6, and 8.0 I< factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY -FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 112 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (112inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 114 inch (6,4 mm) of recessed adjust- ment or up. to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be •cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING' that provides cautions with respect to handling and instal- lation ofsprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 1 tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas /chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY -FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data SheetTFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this documeK as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any otherauthoriiies hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper I operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. AUGUST, 2007 .R µ� •. 1. A,, Model/Sprinkler Identification Numbers TY1131 - Upright 2.8K, 112 "NPT TY1231 - Pendent 2.8K, 112 "NPT TY2131 - Upright 4.2K,1/2 "NPT TY2231 - Pendent 4.2K,112 "NPT :« x. Upright 5.6K, 112 NPT 'fY3241 .,.., P,enrlerit56K >:412 TY4�i31-- Upnght 6.6k, 314 "NPT- TY4231 - Pendent 8.0K, 314 "NPT TY4831- ;,,yam• -r TY4931- Pendent 8.0K, 112 "NPT .R µ� •. 1. A,, Model/Sprinkler Identification Numbers TY1131 - Upright 2.8K, 112 "NPT TY1231 - Pendent 2.8K, 112 "NPT TY2131 - Upright 4.2K,1/2 "NPT TY2231 - Pendent 4.2K,112 "NPT TY3131 Upright 5.6K, 112 NPT 'fY3241 .,.., P,enrlerit56K >:412 TY4�i31-- Upnght 6.6k, 314 "NPT- TY4231 - Pendent 8.0K, 314 "NPT TY4831- Upright 8.0K,112 "NPT TY4931- Pendent 8.0K, 112 "NPT TFP171 TFP171 ESCUTCHEON PLATE SEATING SURFACE 7- 2 -3116" (55,6 mm) 7116" (11,1 mm) NOMINAL 11T MAKE -IN &Iryr STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR 7116" (11,1 mm) NOMINAL MAKE -IN 2 -3116" WRENCH (55,6 mm) FLATS 112" NPT SSP DEFLECTOR * [ — 2 718" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT Page 3 of 10 6* CROSS SECTION 1 - Frame 3 - Suing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 112 INCH NPT ESCUTCHEON 112" (12,7 mm) PLATE SEATING NOMINAL SURFACE 3W MAKE -IN 2 -5116" (58,7 mm) 1 -9116" (39,7 mm) STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR WRENCH FLATS SSP DEFLECTOR* 2 -718" (73,0 mm) DIA. PENDENT RECESSED PENDENT 314" NPT UPRIGHT (12,7 mm) NOMINAL MAKE -IN i I 7 (57,,2 2 mm) 6* CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb • 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 314 INCH NPT I � CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb • 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 314 INCH NPT L:/BLT° Galvanized and Black Lightwall Threadable Pipe The original "Galvanized" and "Black" Threadable Lightwall pipes with exceptional hydraulics and economy. XL®/BLT ®'s proven hydraulic advantage and lighter weight adds value to any system. When you need a proven sprinkler pipe, specify XUBLT. XUBLT pipe are an exceptionally strong steel sprinkler pipe of the class generally known as "lightwall threadable pipe ". Its wall thickness is less than that of Sch-40 or Sch -10, but the cold forming process undergone in manufacturing gives XLBLT pipe mechanical strength characteristics equivalent to those required for Sch -40. It is designed for use in wet, dry, preaction and deluge systems. XUBLT can be joined with threaded couplings (when in accordance with ANSI B1.20.1), roll grooved or plain -end couplings, or welded joints. XU BLT products have metallurgical properties which provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No special process or equipment are needed for fabrication and installation. XL is manufactured with galvanized coating. BLT is black lacquer coated. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is fast installed. 1'/,' 1.452 1.46 Specifications 32 36.9 2.3 NPS Nominal I.O. Wt. Wt. (H20 Flled) PCs/ WMUft (21') WVl ift (24') WVUR (25') in, • mm fn; mm O&R,, Kg/m Lb&R,• Kg/m Lift Lbs; Kg Lbs; Kg Lbs,- Kg 1' 1.104 1.13 1.61 91 2,333 2,667 2,570 25 28.0 1.8 2.40 91 1,060 1,211 1,228 1'/,' 1.452 1.46 2.25 32 36.9 2.3 3.35 1'h' 1.687 1.76 2.84 40 428 2.8 4.23 2' 2.154 2.35 4.06 50 54.7 3.7 6.04 2'h'* 2.581 4.08 6.34 65 65.5 6.05 9.45 3'* 3.200 5.01 8.49 80 81.2 7.43 12.7 * XL only XUBLT pipe is manufactured to meet ASTM A -135, Grade A for fire sprinkler applications up to 300 psi working pressure. UL FM UDC Listed Approved Listed It is UL listed for wet, dry, preaction and deluge systems, and FM approved for wet sprinkler systems. XL/BLT is ULC listed for-wet, dry and preaction systems. All threaded and welded fittings are approved in accordance with NFPA 13. FM requires 12' maximum hanger spacing for XUBLT. C Factors for XU BLT are 120 for wet systems, and C =100 for dry systems. Refer to Hazen - Williams charts for accurate flow comparisons. 61 2,019 2,307 2,226 61 917 1,048 1,058 61 2,409 2,753 2,684 61 1,094 1,250 1,294 37 1,959 2,239 2,173 37 890 1,017 1,041 30 2,571 2,939 3,060 30 1,168 1,335 1,390 19 1,999 2,285 2,380 19 908 1,038 1,081 XL/BLT pipe offers the maximum hydraulic advantage of any available threadable sprinkler pipe. Its inside diameter is up to 5% larger than Sch -40. The use of XUBLT in conjunction with Dyna -Flow pipe, can dramatically improve the flow characteristics, thereby increasing the potential for "downsizing" system components. The clean surface quality of XUBLT is readily paintable. The lighter weight of XL/BLT is a distinct advantage for retro-fit installations and can also reduce labor costs. tZ�C ® /F /ow Conrrol ^I��p� 16100 S. Lathrop - Harvey, IL 60426 Customer Service: allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882 -5543 TUBE & CONDUrr 2525 N. 27 th Ave. - Phoenix, AZ 85009 Fax 708 -339 -1806 S4 -3 CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES _ / PHONE # 407 -302 -2516 - FAX # 407 - 302 -2526 DATE: //3�a� PERMIT #: U Y-I 3 BUSINESS NAME / PROJECT: ADDRESS: r i PHONE NO.: �02 ,x'72 -- 7,? FAX NO.: CONST. INSP. [ ] C / O INSP.:( j REINSPECTION [ ] PLANS REVIE F. A. [. ] F. S. [ ] HOOD (j PAINT BOOTH [ ] BURN OfR ITI [ ] TENT PERMIT f ] TANK PERMIT [ ] OTHER [ ] TOTAL FEES; S 6q) (PER UNIT SEE BELOW) COMMENTS: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Address/ Bldg. # / Unit # Sguare Footage Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, Fl. 32771 Phone # -407- 330 -5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. Sa d Fire evention Division Applicant's Signature