Loading...
HomeMy WebLinkAbout3798 Orlando Dr 09-2029 CITY OF SANFORD PERMIT APPLICATION Application # : —// Submittal Date: 1012-1 Job address: C VJ- AX&.^o,,A GY - 3 7/ q o S• t rAetA br. Value of Work: S Z-/ 0 E 00 Parcel ID: 3-5-5-/F- 0 -� 00oo- 6c).7'ioning: Historic District: Description of Wort..'` Q p/AGe -. �/ i4T'„i /'t_q d4 -AA eLq e d FRCP Square Footage: .... ............................... f ...... .......... ...... ....•........•..•.............. • .................... Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler /Alarm Pool ❑ Sign ❑ Electrical: New Service — # of AMPS Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑ Mechanical: Residential ❑ Non - Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Litres Plumbing/New Residential: # of Water Closets Occupancy. Type: Residential ❑ Commercial Industrial ❑ Construction Type: # of Stories: _� # of Dwelling Units: Plumbing Repair- Residential ❑ //Commercial ❑ // Occupancy Use Group(s): ?VI � �m O-t V - AP_7 1 Flood Zone: (FEMA form required) ................................................. ............................... Property Owner: 5'0.r de f'lt r � r s 3 C . lh C . Contractor: 4 / r'o -leC h/ , �V.77 /_fPVLS Address: iom t` CVs !'/ t Address: I S S I-a Q T D 9 S' 1.2r1a h cGo . FL 3 ZtD �J Phone: E -mail: �Plt�onla �2 ^ / Z68 State License Number: Bonding Company: Address: Architect/Engineer: Address: Plan Review Contact Person: Mortgage Lender: Address: Phone: Fax: Phone: Fax: E -mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, I (EATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON Tl {E JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acce ce of permit u verification that [will notify the owner of the property the r uirements of Florida Lien Law. 1'S 713. _( Signa o Owner /A ent Date Signal r-ofContractor /Agent Date Print Owner /Agent's Name Print tractor /Agent's Na Signature of Notary-State of Florida Date Signature of Notary-State of Florida Date Owner /Agent is _ Personally Known to Me or Produced ID APPROVALS: ZONING: UTIL: FD: Special Conditions: Rev 07.07 Contractor /Agent is _ Pe ff I pwn to.lv�t Produced ID l.__ / � 6� A'b'p hn • , y ENG tt•+ • � —7 Y J iPuVt✓2 y. :i (P .L�C�aanU�'\ SlutmNc)o `' ' SINCE 1873 AFA Protective Systems, Inc. 1255 LaQuinta Drive Suite 100A Orlando, Florida 32809 License #EF0001 116 407.812.9200 Fax 407.812.9205 October 21, 2008 City of Sanford Building Department — 2nd Floor 300 N. Park Avenue Orlando, Florida 32771 Re: CVS PHARMACY — STORE # 0219 3798 SOUTH ORLANDO DRIVE SANFORD, FLORIDA 32773 Please be advised that I have authorized " Jeff Parker `r to pull the Permit for the Installation of the Fire Alarm System, at the above - mentioned job, using my license number EF- 0001116. Thank you for your cooperation. Very Truly Yours, AFA PROTECTIVE SYSTEMS, INC. f)"'a' cs'��� Osvaldo R. Molina Operations Manager Signed before me in Orange County, Florida this -,S. f day of a F�1, _L-1 „, --)o by Osvaldo R. Molina who is personally known to me and did not take an oath. 1 olleen Lovejoy l 1 Notary Public — State of Florida My Commission expires: = = °s`c:�COLLEEN M LOVEJOY =* `' My COMMISSION # DD749780 EXPIRES January 17, 2012 (407)398.0153 FloridallotaryService.com Connecticut • Delaware • Florida • Georgia . Maine . Maryland . Massachusetts . North Carolina . New Hampshire New Jersey . New York . Pennsylvania . Rhode Island . South Carolina . Vermont . Virginia ...................................... ........................................................... .......................................................................... .................. ................... A A AFA Protective Systems, Inc. me.'M 1255 LaQuinta Drive Suite 100A SINCE 1873 rMMIT Orlando, Florida 32809 License #EF0001 116 407.812.9200 Fax 407.812.9205 SUBMITTALS Ir"MI REPLACE LIGHTNING DAMAGED FIRE ALARM CONTROL PANEL & ANNUNCIATOR PANEL AT "CVS PHARMACY -STORE # 0219" 3798 SOUTH ORLANDO DRIVE SANFORD, FLORIDA 32773 Connecticut - Delaware Florida • Georgia - Maine - Maryland - Massachusetts o North Carolina . New Hampshire New Jersey e New York - Pennsylvania - Rhode Island - South Carolina e Vermont o Virginia Table of Contents — CVS Pharmacy Store # 0219 1. AFA Protective Systems, Inc. State EF License 2. AFA Protective Systems, Inc. Occupational License 3. AFA Protective Systems, Inc. Certificate Of Insurance 4. AFA Protective Systems, Inc. UL Certificate Of Compliance 5. Letter (Scope of Work) 6. Firelite MS- l0UD -7 Fire Alarm Control Panel 7. Firelite ANN -80 Fire Alarm Annunciator Panel 8. Firelite PS Series Battery 9. Ditek DTK- MRJ31XSCPWP Surge Suppression 10. Ditek DTK120HW Surge Suppression 11. Ditek DTK2LVLP Surge Suppression 12. Stand -by Battery Calculations A A ® S SINCE 1873 October 21, 2008 City of Sanford Building Department 300 N. Park Avenue Sanford, Florida 32771 RE: CVS PHARMACY — STORE # 0219 3798 SOUTH ORLANDO DRIVE SANFORD, FLORIDA 32773 AFA Protective Systems, Inc. 1255 LaQuinta Drive Suite 100A Orlando, Florida 32809 License #EF0001 116 407.812.9200 Fax 407.812.9205 AFA Protective Systems to replace the existing lightning damaged Fire Alarm Control Panel and Fire Alarm Annunciator Panel, with a new Firelite MS- l0UD -7 Fire Alarm Control Panel and a new Firelite ANN -80 Fire Alarm Annunciator Panel, at the above location. AFA Protective Systems to connect all remaining Fire Alarm devices to the new Fire Alarm Control Panel. Please contact me with any questions at (407) 812 -9200. Sincerely, Jeff Parker AFA Protective Systems, Inc. Connecticut • Delaware • Florida • Georgia • Maine • Maryland • Massachusetts . North Carolina . New Hampshire New Jersey • New York • Pennsylvania • Rhode Island • South Carolina • Vermont • Virginia M S -S U D -3 /M S -10 U D -7 (E ) Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel General The MS -5UD -3 is a five -zone FACP (Fire Alarm Control Panel) and the MS- 10UD -7(E) is a ten -zone FACP. These control pan- els provide reliable fire signaling protection for small to medium -sized commercial, industrial, and institutional build- ings. Both panels include built -in communicators for Central Station Service and remote upload /download. Each of these FACPs is compatible with System Sensor's microprocessor -based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS -5UD -3 and MS- 1OUD -7 are compatible with conventional input devices such as two- and four -wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally -open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form -C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally - open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN -6F and FireLite's new IPDACT Internet Monitoring module. The IPDACT permits monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE. The MS- 10UD -7E offers the same features as the MS- 1OUD -7 but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. Features • Listed to UL Standard 864, 9th edition. • Built -in DACT (Digital Alarm Communicator/Transmitter). • Style B (Class B) IDC (Initiating Device Circuit) — MS -5UD -3 - five IDCs. — MS- 10UD -7 - ten IDCs. • Style Y (Class B) NAC (Notification Appliance Circuit) - spe- cial application power — MS -5UD -3 - four NACs. — MS- 10UD -7 - four NACs. • Notification Appliances may be programmed as — Silence Inhibit. — Auto - Silence. — Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. DF- 52416:13 • A3 -20 8 Fire•uTeALarms by Honeywell — Selective Silence (horn- strobe mute). — Temporal or Steady Signal. — Silenceable or Nonsilenceable. • Optional CAC -5X Style Z (Class A) Converter Module for NACs and IDCs (2 required for MS- 10UD -7). • Form -C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive). • 3.0 A total system current for MS- 5UD -3. • 7.0 A total system current for MS- 10UD -7. • Optional Dress Panel DP -51050 • Optional Trim Ring TR -CE for semi -flush mounting. • 24 volt operation. • Low AC voltage sense. • Alarm Verification. • PAS (Positive Alarm Sequence). • Automatic battery trickle charger. • Up to eight ANN -BUS annunciators: — Optional 8 zone Relay Module ANN -RLY. — Optional LED Annunciator Module ANN -LED, — Optional Remote Annunciator ANN -80. — Optional Remote Printer Gateway ANN -S /PG. — Optional LED Annunciator Driver ANN -1 /0. • Optional 4XTMF module (conventional reverse polarity /city box transmitter). PROGRAMMING AND SOFTWARE. Can be programmed at the panel with no special software or additional equipment. Programmable Make /Break Ratio. Upload /Download (local or remote) of program and data via integral DACT. DF- 52416:8 •07/10/08 — Page 1 of 4 USER INTERFACE. • Built -in DACT (Digital Alarm Communicator/Transmitter). • Integral 80- character LCD display with backlighting and keypad. • Real -time clock/calendar with automatic daylight savings adjustments. • ANN -BUS for connection to remote annunciators. • Audible or silent walk test capabilities. • Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS • FIRE ALARM (red) • SUPERVISORY (yellow) • TROUBLE (yellow) • AC POWER (green) • ALARM SILENCED (yellow) CONTROL BUTTONS • ACKNOWLEDGE • ALARM SILENCE • SYSTEM RESET (lamp test) • DRILL Terminal Blocks AC Power — TB1: • MS -5UD -3 (FLPS -3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. • MS- 10UD -7 (FLPS -7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. • MS- 10UD -7E (FLPS -7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower- limited. Battery (sealed lead acid only) — J12: • Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC 1.4 A. Supervised, nonpower - limited. • Maximum Charger Capacity: 18 AH battery for MS- 5UD -3, and 26 AH battery for MS- 10UD -7(E). [Two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB -26 or BB -55] • Minimum Battery Size: 7 AH. Depth l= 5.207" (13.23 cm) Top - - i Door = 19.26" (48.92 cm) Backbox = 19.0" (48.26 cm) Left Side Bottom Page 2 of 4 — DF- 52416:8. 07/10/08 Door = 16.821" (42.73 cm) 0 Depth = f Backbox = 16.65" (42.29 cm) f— 5.257" —► (13.353 cm) Cabinet Measurements (D j I M Right Side Initiating Device Circuits — TB4 (and TB 6 on MS- 10UD -7 only): • Alarm Zones 1 - 5 on TB 4 (MS -5UD -3 and MS- 10UD -7). • Alarm Zones 6- 10 on TB6 (MS- 10UD -7 only). • Supervised and power - limited circuitry. • Operation: All zones Style B (Class B). • Normal Operating Voltage: Nominal 20 VDC. • Alarm Current: 15 mA minimum. • Short Circuit Current: 40 mA max. • Maximum Loop Resistance: 100 ohms. • End -of -Line Resistor: 4.7K ohm, 1/2 watt (P /N 71252 UL- listed). • Standby Current: 2 mA. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Notification Appliance Circuits —TB5 (and TB 7 on MS- 10UD -7 only): • Four NACs • Operation: Style Y (Class B) • Special Application power • Supervised and power - limited circuitry • Normal Operating Voltage: Nominal 24 VDC • Maximum Signaling Current: 3.0 A for MS- 5UD -3, 2.5 A maximum per NAC; 7.0 A for MS- 10UD -7(E), 3.0 A maxi- mum per NAC. • End -of -Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) • Max. Wiring Voltage Drop: 2 VDC Refer to the Fire-Lite Device Compatibility Document for com- patible listed devices Form C Relays — T138: • Relay f (factory default programmed as Alarm Relay) • Relay 2 (factory default programmed as fail -safe Trouble Relay) • Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power — TB9: • Jumper selectable by JP31 for resettable or nonresettable power. • Operating voltage: 24 VDC nominal. • Maximum available current: 500 mA - appropriate for pow- ering four -wire smoke detectors. • Power - limited circuit. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - T132; Remote power supply synchro- nization output, only required for the MS- 5UD -3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End -of -Line Resistor: 4.7K ohm. Supervised and power -lim- ited circuit. Ordering Information MS- 5UD -3: Five -zone, 24 -volt Fire Alarm Control Panel (includes backbox, FLPS -3 power supply, technical manual, and a frame & post operating instruction sheet). MS- 10UD -7: Ten -zone, 24 -volt Fire Alarm Control Panel (includes backbox, FLPS -7 power supply, technical manual, and a frame & post operating instruction sheet). MS- 10UD -7E: Same as above with 240 VAC FLPS -7. IPDACT: Internet monitoring module. Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df -52424 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: Y Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC -5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS -5UD -3 and MS -10UD- 7(E) main circuit board and to J7 on the MS- 10UD -7(E). NOTE: Two Class A Converter Modules are required for the ten - zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPATIBLE ANNUNCIATORS ANN -80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (A white version is also available: ANN- 80 -W.) ANN -LED: Mounts in the DP- 51050(B) dress panel and pro- vides three LEDs for each zone: Alarm, Trouble, and Supervi- sory. ANN -RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN -S /PG: Serial /parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN -110: Driver module. Provides connections to a user -sup- plied graphic annunciator. ACCESSORIES DP- 51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB -26: Battery backbox, holds up to two 25 AH batteries and CHG -75. BB -55: Battery backbox, holds up to two 25 AH batteries. TR -CE: Optional trim -ring for semi -flush mounted cabinets. PRN -6F: UL listed printer. DF- 52416:B • 07/10/08 — Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity • Annunciators ........................................ ..............................8 Electrical Specifications • MS -5UD -3 (FLPS -3 Power Supply): 120 VAC, 50/60 HZ, 1.0 A • MS- 10UD -7 (FLPS -7 Power Supply): 120 VAC, 50/60 HZ, 3.8 A • MS- 10UD -7E (FLPS -7 Power Supply): 240 VAC, 50/ 60 HZ, 2.2A • Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower - limited Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR -CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: — 20.00' (50.80 cm.) high — 22.5" (57.15 cm.) wide — 8.5' (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49 °C/32 — 120 °F and at a relative humidity 93% t 2% RH (noncondensing) at 32 "C t 2 °C (90 °F t 3 °F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27 °C /60 — 80 °F. Agency Listings and Approvals The listings and approvals below apply to the basic MS -5UD -3 and MS- 10UD -7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. • UL Listed: File S624 • FM Approved • CSFM: 7165- 0075:214 • MEA: MEA:333 -07 -E NFPA Standards The MS- 5UD- 3 /MS- 10UD -7(E) complies with the following NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet - switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. B19111811N19MAMFACTIRI111 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105. www.firelite.com Page 4 of 4 — DF- 52416:B • 07/10/08 df- 52417:b • B -90 ANN -so OFM •�iTe A�arms 80- Character LCD Serial Annunciator by Honeywell - - - Annuncrrators ' The ANN -80 annunciator is a compact, backlit, 80- character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN -80 and the FACP communicate over a two -wire serial interface employing the ANN -BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL- listed, filtered power supply. ANN -80 is red; for white, order ANN -80 -W. The ANN -80 displays English- language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) _a Up to eight ANN -80s may be connected to the ANN -Bus of each FACP. No programming is required, which saves time during " system commissioning. Features • Listed to UL Standard 864, 9th Edition. • Backlit 80- character LCD display (20 characters x 4 lines). • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill, and Reset. • Control switches can be independently enabled or disabled at the FACP. • Keyswitch enables /disables control switches and mechani- cally locks annunciator enclosure • Keyswitch can be enabled or disabled at the FACP. • Enclosure supervised for tamper. • System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. • Local sounder can be enabled or disabled at the FACP. • ANN -80 connects to the ANN -BUS terminal on the FACP and requires minimal panel programming. • Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. • Time -and date display field. • Aesthetically pleasing design constructed of durable Lexan. • Surface mount directly to wall or to single, double, or 4" square electrical box. • Semi -flush mount to single, double, or 4" square electrical box. • Can be remotely located up to 6,000 feet (1,800 m) from the panel. • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). • Up to eight ANN -80s can be connected on the ANN -BUS. Controls and Indicators • AC Power • Alarm • Trouble • Supervisory • Alarm Silenced Specifications • Operating voltage range: 18 VDC to 28 VDC • Current consumption @ 24 VDC nominal (filtered and non - resettable): 40 mA maximum. • Ambient temperature: 32 °F to 120 °F (0 °C to 49 °C). • Relative humidity: 93% t 2% RH (noncondensing) at 32 °C t 2 °C (90 °F t 3 °F). • 5.375' (13.65 cm.) high x 6.875' (17.46 cm.) wide x 1.375' (3.49 cm.) deep. • For use indoors in a dry location. • All connections are power - limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN -80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S2424 • FM approved (ANN -80) • CSFM: 7120- 0075:211 • MEA:442 -06 -E (ANN -80) The ANN -BUS POWERING THE DEVICES ON THE ANN -BUS FROM AUXILIARY POWER SUPPLY The ANN -BUS can be powered by an auxiliary power supply when the maximum number of ANN -BUS devices exceeds the ANN -BUS power requirements. See the FACP manual for more information. df- 52417:b • 05/30/08 — Page 1 of 2 ANN -BUS DEVICE ADDRESSING Each ANN -BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN -BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN -80 connects to the FACP ANN -BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN -BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4- conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN -BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk ('). Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT • 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. • All connections are power - limited and supervised. • A maximum of eight ANN -80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN -BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. ' 6,000 ft. '6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN -BUS devices. ANN -BUS and power wiring are supervised and power - limited. ® B A + -1 TBt 4 3 2 1 ANN -BUS Device + p O MS- 905OUD T83 1 2 3 4 5 6 7 8 FACP Wiring to ANN -BUS Device ORDERING OPTIONS: ANN -80: Red, 80 character LCD Annunciator. ANN -80 -W: White, 80 character LCD Annunciator. FireLfte® Alarms is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I O 900 This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. BICIIf81NC i MANIFACfIMN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105. www.firelite.com Page 2 of 2 — df- 52417:b • 05/30/08 BAT Series Batteries Sealed Lead -Acid BAT Series Batteries feature a new part- numbering /listing sys- tem — providing an improved method of delivery for Fire -Lite- approved sealed lead -acid batteries for all your fire alarm sys- tem needs. Multiple brands of batteries are now offered under generic part numbers, reducing backorder situations and permit- ting us to deliver these products in a more timely fashion. Fire-Lite has approved the multiple brands listed below as pos- sible product shipped for a given part number. Please note that any incoming orders for "PS Series" batteries will be converted to the equivalent BAT Series part numbers. Features • Provide secondary power for control panels. • Sealed and maintenance -free. • Overcharge protected. • Easy handling with leakproof construction. • Ruggedly constructed, high- impact case (ABS, polystyrene, or polypropylene, depending on models). • Long service life. • Compact design. Part Number Reference DF- 52397:A - D -500 (a Fire•LlTeaALarms by Honeywell Power Supp' Iles /Accessories. 6933covpg Agency Listings and Approvals The listings and approvals below apply to BAT Series Batteries. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Recognized Components: files MH19884 (B & B Bat- tery), MH2O727 (UPG, previously Jolt), MH2O845 (Power - Sonic). 6933keyl.tbl PREVIOUS CURRENT BATTERY ALTERNATES APPROVED: Part Number Part Number DESCRIPTION manufacturers and P /Ns shipped under BAT P /Ns PS -612 Discontinued N/A NIA PS -695 Discontinued N /A. N/A PS -1242 BAT -1250 12 V, 5 AH, sealed. BP5 -12 (B &B Battery); PS -1250 (Power- Sonic); SA1250 (Jolt) to be replaced with UB1250 (UPG). PS -1250 BAT -1250 12 V. 5 AH, sealed. BP5 -12 (B &B Battery); PS -1250 (Power- Sonic); SA1250 (Jolt) to be replaced with UB1250 (UPG). PS -1270 BAT -1270 12 V, 7 AH, sealed. BP7 -12 (B &B Battery); PS -1270 (Power- Sonic); SA1272 (Jolt) to be replaced with UB1270 (UPG). PS -12120 BAT -12120 12 V, 12 AH, sealed. BP12 -12 (B &B Battery); PS -12120 (Power- Sonic); SA12120 (Jolt) to be replaced with UB12120 (UPG). PS -12170 BAT -12180 12 V, 18 AH, sealed. PS -12180 (Power- Sonic); SA12180 (Jolt) to be replaced with UB12180 (UPG). PS -12180 BAT -12180 12 V, 18 AH, sealed. PS -12180 (Power- Sonic); SA12180 (Jolt) to be replaced with UB12180 (UPG). PS -12250 BAT -12260 12 V, 26 AH, sealed. BP26 -12 (B &B Battery); PS -12260 (Power- Sonic); SA12260 (Jolt) to be replaced with UB12260 (UPG). PS -12550 BAT -12550 12 V, 55 AH, sealed. PS -12550 (Power- Sonic); XSA12550 (Jolt) to be replaced with UB12550 (UPG). PS -12600 BAT -12550 12 V, 55 AH, sealed. PS -12550 (Power- Sonic); XSA12550 (Jolt) to be replaced with UB12550 (UPG). PS -12750 Discontinued N/A N/A PS- 121000 BAT - 121000 12 V. 100 AH, gel[ cell. PS- 121000 (Power- Sonic); XSA121000A (Jolt) to be replaced with UB121000 (UPG). DF- 52397:A - 12/29/06 — Page 1 of 10 POWER -SONIC 1109t1 tbl MODEL Nominal Voltage V Nominal Capacity @ 20 hr. rate A.H. Discharge Current @ 20 hr. rate mA DIMENSIONS Width in. mm. Depth in. mm. Height in. mm. Height over terminal in. mm. WQ19ht lbs. kg. PS -1250 12 5.0 250 3.54 90 2.76 70 4.02 102 4.21 107 4.1 1.9 PS -1270 12 7.0 325 5.94 151 j 2.56 65 3.70 94 3.86 98 5.7 2.6 PS -12120 12 12 600 5.94 151 1 3.86 1 98 3.70 94 3.86 98 8.8 4.0 PS -12180 12 18 875 7.13 181 2.99 76 6.57 167 6.57 167 12.8 5.8 PS -12250 12 25 1300 6.89 175 6.54 166 4.92 125 4.92 125 18.7 8.5 PS -12550 12 55 3000 10.25 260 6.60 168 8.20 208 9.45 240 39.7 18.0 PS- 121000 12 100 5000 12.00 305 6.60 168 8.20 208 945T240 65.7 29.8 Characteristic Discharge Curves 6.5 13 S 6.0 12 m rn 0 5.5 11 3 _ t.oc 5.0 10 ' 0A75C 05C i 025C m 45 9 06C i 4.0 8 _ _ 3C 2C 1C 0 1 2 3 5 10 2030 60 2 3 5 10 20 30 �. minutes .i hours Discharge Time @ 20 °C (687) 100% 90% 0 tY 80% c c 70% 60% U a 50% U 40% 0% Effect of Temperature on Capacity 120% - - -r- I 1 100% , 1 1 - ---'1-0.5c � 1 0 80% ___ i. _. I-- - j.....i.0.25 C, m ...... 0.6 C 60% - 1 C z c CL co I V40% -' - -' - - -- + -- - -- -� 20% - - -t- -1- - 1- - -20° -10° 0° 10° 20° 30° 40° 50° 60° Temperature (Degrees C.) Charging is NOT necessary unless 100% of capacity LLL, is required. 5 °C at left: 40 °C i 30 °C 2 PS- 121000 (104 °F) (86 °F) i (6 use necessary to help recover j Shelf -Life Effect of Temperature on Capacity 120% - - -r- I 1 100% , 1 1 - ---'1-0.5c � 1 0 80% ___ i. _. I-- - j.....i.0.25 C, m ...... 0.6 C 60% - 1 C z c CL co I V40% -' - -' - - -- + -- - -- -� 20% - - -t- -1- - 1- - -20° -10° 0° 10° 20° 30° 40° 50° 60° Temperature (Degrees C.) 0 2 4 6. - 8 10 12 14 _ -16- __ 18 _ 20 Standing Period (Months) 14.0 V 13.0 V 12.0 V 11.0 v 10.0 V 9.0 V 8.0 V 1.2 2.4 6 12 24 36481 2 4 6 810 20 40^ MINUTES - ---- - - -X-- - HOURS Discharge Time Page 2 of 10 - DF- 52397:A • 12/29/06 at left: PS- 1210000 Discharge Characteristics Charging is NOT necessary unless 100% of capacity LLL, is required. 5 °C at left: (41 F) • Charging before is PS- 121000 use necessary to help recover j Shelf -Life full capacity. and Storage 1 `•. Charge may i I fail to restore 0 °C , full capacity. 8 °F) I !i DO NOT let batteries reach this state., m 0 2 4 6. - 8 10 12 14 _ -16- __ 18 _ 20 Standing Period (Months) 14.0 V 13.0 V 12.0 V 11.0 v 10.0 V 9.0 V 8.0 V 1.2 2.4 6 12 24 36481 2 4 6 810 20 40^ MINUTES - ---- - - -X-- - HOURS Discharge Time Page 2 of 10 - DF- 52397:A • 12/29/06 at left: PS- 1210000 Discharge Characteristics B & B BATTERY Model V Nominal Capacity (AH) Weight Terminal Dimensions Standard Optional L W H TH 20 °C h ) ( °C) 20 hr 10 hr 5 hr 1 hr kg Ibs Type Pos. Type Pos. mm in mm in mm in mm In BP5 -12 12 5.00 4.75 4.25 3.00 1.86 4.10 T1 3 T2 20 90 3.54 70 2.76 102 4.02 106 4.17 BP7 -12 1 12 7.00 6.65 5.95 4.20 2.60 5.73 T2 5 T1 0.3 151 5.94 65 2.56 93 3.66 98 3.86 BP12 -12 12 12.00 11.40 10.20 7.20 4.03 8.89 131 5 T1 151 5.94 98 3.86 94 3.70 98 3.86 BP26 -12 1 12 26.00 24.70 22.10 15.60 9.40 20.73 131 7 T2.11 9 175 6.89 166 6.54 125 4.92 125 4.92 Charging Procedure 6933bbch.tbl Final Discharge Time: for Model BPS-12 5 min Temperature Maximum Charging time 0.1 CA, 1 hr 3 hr 5 hr Charging compensation ccurretnt 20 °C h ) ( °C) Application Charging method voltage at coefficient of 36.39 14.57 Temp ( 5.62 2.94 10.50 V 209.2 20 °C (Vlcell) chi (CA) 37.48 14.87 10.20 5.70 VrC /celQ 10.20 V discharge discharge 115.0 For standby Constant voltage and 2.25-2.30 -3 0.3 24 20 232.3 power source constant current charging (with current 68.3 38.61 I I 5.75 0 - 40 °C (32- 104 °F) For cycle r240-250 156.0 120.0 69.0 39.00 service restriction) 5.75 -4 0.3 16 10 Temperature compensation of charging voltage is not needed Men using the batteries within 5 °C to 35 °C range. Final Discharge Time: for Model BPS-12 5 min 10 min 15 min 30 min 1 hr 3 hr 5 hr 10 hr 20 hr Voltage Battery Output Power (%M: for Model BP5 -12 10.80 V 180.8 133.1 106.6 63.5 36.39 14.57 10.05 5.62 2.94 10.50 V 209.2 144.2 111.5 65.9 37.48 14.87 10.20 5.70 3.00 10.20 V 222.3 149.4 115.0 67.4 38.16 15.00 10.26 5.73 3.01 9.90 V 232.3 152.9 117.6 68.3 38.61 15.10 10.29 5.75 3.02 9.60 V 1 240.0 156.0 120.0 69.0 39.00 1520 10.32 5.75 3.02 Constant Power Discharge Characteristics at 25 °C177 0F for BP5 -12 Constant Power Discharge Characteristics at 25 °C/77 °F for BP7 -12 Constant Power Discharge Characteristics at 250C177 °F for BP12 -12 Constant Power Discharge Characteristics at 25 °C/77 °F for BP26 -12 DF- 52397:A • 12/29/06 - Page 3 of 10 Discharge Time: for Model BP7 -12 Final 5 min 10 min 1 15 min 1 30 min 1 1 hr 3 hr 1 5 hr 1 10 hr 20 hr Voltage Battery Output Power (W): for Model BP7 -12 10.80 V 253.1 186.3 149.3 88.8 50.95 20.40 14.07 7.86 4.11 10.50 V 1 292.9 201.8 156.2 92.2 52.47 20.81 14.28 7.98 4.20 10.20 V 311.2 209.1 161.0 94.3 53.42 21.00 14.36 8.02 4.22 9.90 V 325.2 214.1 164.7 95.6 54.06 21.15 14.41 8.04 4.23 9.60 V 336.0 218.4 168.0 96.6 54.60 21.27 14.45 8.04 4.23 Constant Power Discharge Characteristics at 25 °C177 0F for BP5 -12 Constant Power Discharge Characteristics at 25 °C/77 °F for BP7 -12 Constant Power Discharge Characteristics at 250C177 °F for BP12 -12 Constant Power Discharge Characteristics at 25 °C/77 °F for BP26 -12 DF- 52397:A • 12/29/06 - Page 3 of 10 Discharge Time: for Model BPI 2-12 Final 5 min 1 10 min 15 min 1 30 min 1 1 hr 3 hr 1 5 hr 1 10 hr 20 hr Voltage Battery Output Power (%q: for Model BPI 2-12 10.80 V 433.9 319.4 256.0 152.3 87.34 34.98 24.12 13.48 7.05 10.50 V 502.2 346.0 267.7 158.1 89.96 35.68 24.48 13.68 7.20 10.20 V 1 533.6 358.5 276.0 161.7 91.57 36.00 24.61 13.75 7.23 9.90 V 557.5 367.1 282.4 164.0 92.67 36.25 24.70 13.79 7.25 9.60 V 1 576.0 374.4 288.0 165.6 93.60 36.47 24.77 13.79 7.25 Constant Power Discharge Characteristics at 25 °C177 0F for BP5 -12 Constant Power Discharge Characteristics at 25 °C/77 °F for BP7 -12 Constant Power Discharge Characteristics at 250C177 °F for BP12 -12 Constant Power Discharge Characteristics at 25 °C/77 °F for BP26 -12 DF- 52397:A • 12/29/06 - Page 3 of 10 Discharge Time: for Model BP26 -12 Final 5 min 10 min 15 min 30 min 1 hr 3 hr 5 hr 10 hr 20 hr Voltage Battery Output Power (VI): for Model BP26 -12 10.80 V 940.0 692.0 554.6 330.0 189.23 75.79 52.25 29.20 15.26 10.50 V 1 1088.0 749.7 580.0 342.5 194.91 77.30 53.04 29.64 15.60 10.20 V 1156.0 776.7 598.0 350.3 198.41 78.00 53.33 29.79 15.67 9.90 V 1208.0 795.3 611.8 355.2 200.79 78.54 5152 29.88 15.71 9.60 V 1248.0 811.2 624.0 358.8 202.80 79.01 53.68 29.88 15.71 Constant Power Discharge Characteristics at 25 °C177 0F for BP5 -12 Constant Power Discharge Characteristics at 25 °C/77 °F for BP7 -12 Constant Power Discharge Characteristics at 250C177 °F for BP12 -12 Constant Power Discharge Characteristics at 25 °C/77 °F for BP26 -12 DF- 52397:A • 12/29/06 - Page 3 of 10 B & B BATTERY BP5 -12 Battery Discharge Characteristics (25OC177 °F) 13.0 12.0 > W (ry 11.0 F J �j 10.0 zZ :E 9.0 Q W H 8.0 7.0 1 2 3 5 10 20 30 60 2 3 5 10 20 30 minutes 1 hours j DISCHARGE TIME BP05dis.lir 13.0 12.0 0 11.0 J 9 10.0 z 9.0 Q W ♦- 8.0 7.0 BP12 -12 Battery Discharge Characteristics (25 °C/77 °F) BP7 -12 Battery Discharge Characteristics (250C177 °F) 130 12.3 w (� 11.3 F, 10.0 J z Z � 9.0 Q W I- 8.0 7.0 1 2 3 5 10 20 30 GO 2 3 5 10 20 30 minutes hours BPo7dis.61 DISCHARGE TIME 133 120 W 0 0 11.0 \ minutes I hOUfS I J 1 '4.42A 2.47A 13A M BP12dis.hl I 6.SA DISCHARGE TIME > 10.0 a Z i 756A � 9.0 w W � so F 78A 52A 26A 7.0 1 2 3 5 10 20 30 60 2 3 10 20 30 minutes hours BP26dis.til _ DISCHARGE TIM BP26 -12 Battery Discharge Characteristics (25OC/77 °F) BP05 -12 Page 4 of 10 — DF- 52397:A - 12129106 BP12 -12 e BP26 -12 E lk 'Ell .1,.'1„LM,..1 BP7 -12 Battery Discharge Characteristics (250C177 °F) 130 12.3 w (� 11.3 F, 10.0 J z Z � 9.0 Q W I- 8.0 7.0 1 2 3 5 10 20 30 GO 2 3 5 10 20 30 minutes hours BPo7dis.61 DISCHARGE TIME 133 120 W 0 0 11.0 \ minutes I hOUfS I J 1 '4.42A 2.47A 13A M BP12dis.hl I 6.SA DISCHARGE TIME > 10.0 a Z i 756A � 9.0 w W � so F 78A 52A 26A 7.0 1 2 3 5 10 20 30 60 2 3 10 20 30 minutes hours BP26dis.til _ DISCHARGE TIM BP26 -12 Battery Discharge Characteristics (25OC/77 °F) BP05 -12 Page 4 of 10 — DF- 52397:A - 12129106 BP12 -12 e BP26 -12 UPG BATTERY UB1250 has the same specifications as previous Jolt SA1250, SA1272 to be replaced with UB1270 (specs/diagrams pending). UB1250 (previously SA1250) Diagrams SA1272 Diagrams UB12501SA1250 discharge current vs. time SA1272 discharge current vs. time ;hi ;rdtj 1111 WIN 111111 0 530 1 2 3 5 10 23 30 50 100 203 r-- imAl --0 F - ',A1 0 6933up0f.bf CtrreM UB12501SA1250 discharge characteristics (25 °C177 °F) 1. 0 1 1 2 3 5 10 20 9.0 00 2 1 5 1J 20 l0 6933up02.Uf D i9charoe Time UB1250, SA1250 Specifications • Nominal voltage: 12 V. • Nominal capacity (20 hr): 5.0 AH. • Dimensions: total height 107 mm (4.21 "); container height 101 mm (3.98 "); length 90 mm (3.54 "); width 70 mm (2.76 "). • Weight: approximately 1.83 kg (4.03 Ibs). • Container material: UL94HB ABS, UL94V -0 ABS. • Internal resistance (25 °C, 77 °F): - 32 m. • Discharge capacity under different temperatures: 40 °C: - 102% 25 °C: - 100% 0 °C: ^- 85% • Capacity 25'C/77 °F: 20 hr @0.25 A: 5.0 AH. 5 hr @ 0.8 A: 4.0 AH. 1 hr @3.0A: 3.0 AH. 1 C @ 5.0 A: 2.5 AH. • Charging voltage (25 °C, 77 °F): Standby use: 13.65 V t 0.15 V. Cycle use: 14.7 V t 0.3 V. • Maximum discharge current: 60 A (5 sec). • Maximum charging current: 1.5 A. • Self- discharge residual capacity (25 °C, 77 °F): After 3 months: - 90 %. After 6 months: - 82 %. After 12 months: - 70 %. ii r; F' (nhj Uc(32F) 0 500 1 2 3 5 10 23 33 53 100 203 TA, iAl 6933up03.6f Ctr:erA SA1272 discharge characteristics (25°C177 °F) y 12 a, 9 0 1 23 5 10 Z)3) 03 2 3 5 10 Z)30 6933up04.61 Dac'lamae Timor SA1272 Specifications • Nominal voltage: 12 V. • Nominal capacity (20 hr): 7.2 AH. • Dimensions: total height 100 mm (3.94 "); container height 94 mm (3.70 "); length 151 mm (5.95 "); width 65 mm (2.56 "). • Weight: approximately 2.66 kg (5.85 Ibs). • Container material: UL94HB ABS, UL94V -0 ABS. • Internal resistance (25 °C, 777): - 22 m. • Discharge capacity under different temperatures: 40 °C: - 102% 25 °C: - 100% 0°C: -- 85% • Capacity 25 °C /77 °F: 20 hr @ 0.36 A: 7.2 AH. 5 hr @ 1.15 A: 5.76 AH. 1 hr @ 4.32 A: 4.32 AH, 1 C @ 7.2 A: 3.6 AH. • Charging voltage (25 °C, 77 °F): Standby use: 13.65 V t 0.15 V. Cycle use: 14.7 V t 0.3 V. • Maximum discharge current: 90 A (5 sec). • Maximum charging current: 2.16 A. • Self- discharge residual capacity (25•C, 77 °F): After 3 months: - 90 %. After 6 months: - 82 %. After 12 months: - 70 %. DF- 52397:A • 12129/06 - Page 5 of 10 UPG BATTERY Same specifications as previous Jolt models; packaging and part numbers are the only changes. UB12120 (was SA12120) Diagrams UB121201SA12120 discharge current vs. time T- 53 ^1 2 1 1 so 20 lTln; 10 I5 3 0I- 500 1 2 3 5 10 20 111 50 101 200 I�(m11 - >ii (Al �I UB12180 (was SA12180) Diagrams UB121801SA12180 discharge current vs. time F (n 1q1 i♦ i♦ i♦ ■ i♦ i♦ f♦ ■ i♦ i♦ i♦ i♦ i♦ i•i•i• ■i•�i•��i•i•i•i• i_ i• i• ■ i• i• i• ■ t i• i• i• i• 0 530 1 2 3 5 10 20 3) 50 100 203 k--imA1- --Oils -VAI -� 6933upO5.Cf CuTard 6933upO7.fif Curenl UB121201SA12120 discharge characteristics (25'C/77 °F) UB121801SA12180 discharge characteristics (25 °C177 °F) OEM= Nis WWII 0100■'■ 1 2 3 5 10 2) 31 d0 2 3 5 10 20 3) 6933upO6.fif D.,sc Lrge Tirre UB12120, SA12120 Specifications • Nominal voltage: 12 V. • Nominal capacity (20 hr): 12.0 AH. • Dimensions: total height 100 mm (3.94 "); container height 94 mm (3.70 "); length 151 mm (5.95'); width 98 mm (3.86 "). • Weight: approximately 4.10 kg (9.04 Ibs). • Container material: UL94HB ABS, UL94V -0 ABS. • Internal resistance (25 °C, 77 °F): -- 14 m. • Discharge capacity under different temperatures: 40 °C: 102% 25 °C: - 100% 0 °C: - 85% • Capacity 25 °C/77 °F: 20 hr @ 0.6 A: 12.0 AH. 5 hr @ 1.92 A: 9.6 AH. 1 hr @ 7.2 A: 7.2 AH. 1 C @ 12.0 A: 6.0 AH. • Charging voltage (25 °C, 77 °F): Standby use: 13.65 V t 0.15 V. Cycle use: 14.7 V t 0.3 V. Maximum discharge current: 120 A (5 sec). Maximum charging current: 3.6 A. Self- discharge residual capacity (25 °C, 77 °F): After 3 months: - 90 %. After 6 months: - 82 %. After 12 months: - 70 %. Page 6 of 10 - DF- 52397:A • 12/29106 M 12 A' 11 10 1 )dA dA 0 1 2 3 5 10 20 33 60 2 3 5 10 21330 6933upO6.fif DScharge Time UB12180, SA12180 Specifications • Nominal voltage: 12 V. • Nominal capacity (20 hr): 18.0 AH. • Dimensions: total height 167 mm (6.58 "); container height 167 mm (6.58 "); length 181 mm (7.13 "); width 76 mm (2.29 "). • Weight: approximately 6.06 kg (13.36 Ibs). • Container material: UL94HB ABS, UL94V -0 ABS. • Internal resistance (25 °C, 77 °F): - 13 m. • Discharge capacity under different temperatures: 40 °C: -- 102% 25 °C: - 100% 0 °C: -- 85% • Capacity 25 °C/77 °F: 20 hr @ 0.9 A: 18.0 AH. 5hr @2.88 A: 14.4 AH. 1 hr @ 10.8 A: 10.8 AH. 1 C @ 18.0 A: 9.0 AH. • Charging voltage (25 °C, 77 °F): Standby use: 13.65 V t 0.15 V. Cycle use: 14.7 V t 0.3 V. • Maximum discharge current: 300 A (5 sec). • Maximum charging current: 5.4 A. • Self- discharge residual capacity (25 °C, 77 °F): After 3 months: - 90 %. After 6 months: - 82 %. After 12 months: - 70 %. UPG BATTERY Same specifications as previous Jolt models; packaging and part numbers are the only changes. UB12260 (was SA12260) Diagrams UB122601SA12260 discharge current vs. time ■ ■■ ■Lim\ . ■■ ttttttttttttttttttt��ttttttt�t�ttttttt�ttt�1�� .�1��t��tt� i F- ;mlr•; UB12550 (was SA12550) Diagrams UB125501SA12550 discharge current vs. time rs 2 1 53 30 F 27 5 3 O'C(37F) `}'j 40rC[,,t61 F) 0 500 1 2 3 5 10 20 30 50 100 230 0 530 1 2 3 5 10 23 30 50 100 230 6933up09.01 Current 6933up11 61 Current UB122601SA12260 discharge characteristics (25 °C/77 °F) UB125501SA12550 discharge characteristics (25 °C/77 °F) 10 20 30 60 2 3 5 10 3130 6933up10.ti1 GSG1i3r49 Tura UB12260, SA12260 Specifications • Nominal voltage: 12 V. • Nominal capacity (20 hr): 26.0 AH. • Dimensions: total height 125 mm (4.92 "); container height 125 mm (4.92 "); length 166 mm (6.54 "); width 175 mm (6.89 "). • Weight: approximately 8.80 kg (19.40 Ibs). • Container material: UL94HB ABS, UL94V -0 ABS. • Internal resistance (25 °C, 77 °F): - 10 m. • Discharge capacity under different temperatures: 40 °C: ^- 102% 25 °C: - 100% 0 °C: - 85% • Capacity 25 °C/77 °F: 20 hr @ 1.3 A: 26.0 AH. 5hr @4.16 A: 20.8 AH. 1 hr @ 15.6 A: 15.6 AH. 1 C @ 26.0 A: 13.0 AH. • Charging voltage (25 °C, 77 °17): Standby use: 13.65 V t 0.15 V. Cycle use: 14.7 V t 0.3 V. • Maximum discharge current: 300 A (5 sec). • Maximum charging current: 7.8 A. • Self- discharge residual capacity (25 °C, 77 °F): After 3 months: - 90 %. After 6 months: - 82 %. After 12 months: - 70 %. IF E 12 m 7�1 10 E Fy 9 ■100010010001- 0 1 2 3 5 t0 -2313 032 3 5 10 2330 6933up12.1i1 D r a 4arw Time UB12550, SA12550 Specifications • Nominal voltage: 12 V. • Nominal capacity (20 hr): 55.0 AH. • Dimensions: total height 234.5 mm (9.23 "); container height 216.5 mm (8.52 "); length 229 mm (9.02 "); width 138 mm (5.43 "). • Weight: approximately 19.0 kg (41.8 Ibs). • Container material: UL94HB ABS, UL94V -0 ABS. • Internal resistance (25 °C, 77 °F): -- 8 m. • Discharge capacity under different temperatures: 40 °C: 102% 25 °C: -- 100% 0 °C: - 85% • Capacity 25 °C/77 °F: 20 hr @ 2.75 A: 55.0 AH. 5 hr @ 8.8 A: 44.0 AH. 1 hr @ 33.0 A: 33.0 AH. 1 C @ 55.0 A: 27.5 AH. • Charging voltage (25 °C, 77 °F): Standby use: 13.65 V t 0.15 V. Cycle use: 14.7 V t 0.3 V. • Maximum discharge current: 600 A (5 sec). • Maximum charging current: 16.5 A. • Self- discharge residual capacity (25 °C, 77 °F): After 3 months: - 90 %. After 6 months: - 82 %. After 12 months: - 70 %. DF- 52397:A • 12/29/06- Page 7 of 10 0 1 2 3 5 t0 -2313 032 3 5 10 2330 6933up12.1i1 D r a 4arw Time UB12550, SA12550 Specifications • Nominal voltage: 12 V. • Nominal capacity (20 hr): 55.0 AH. • Dimensions: total height 234.5 mm (9.23 "); container height 216.5 mm (8.52 "); length 229 mm (9.02 "); width 138 mm (5.43 "). • Weight: approximately 19.0 kg (41.8 Ibs). • Container material: UL94HB ABS, UL94V -0 ABS. • Internal resistance (25 °C, 77 °F): -- 8 m. • Discharge capacity under different temperatures: 40 °C: 102% 25 °C: -- 100% 0 °C: - 85% • Capacity 25 °C/77 °F: 20 hr @ 2.75 A: 55.0 AH. 5 hr @ 8.8 A: 44.0 AH. 1 hr @ 33.0 A: 33.0 AH. 1 C @ 55.0 A: 27.5 AH. • Charging voltage (25 °C, 77 °F): Standby use: 13.65 V t 0.15 V. Cycle use: 14.7 V t 0.3 V. • Maximum discharge current: 600 A (5 sec). • Maximum charging current: 16.5 A. • Self- discharge residual capacity (25 °C, 77 °F): After 3 months: - 90 %. After 6 months: - 82 %. After 12 months: - 70 %. DF- 52397:A • 12/29/06- Page 7 of 10 UPG BATTERY Same specifications as previous Jolt models; packaging and part numbers are the only changes. UB121000 (XSA121000A) Diagrams UB1210001XSA121000A discharge current vs. time fi E O'C(37 F) 47 C(104T) 0 5)0 1 2 3 s 10 2030 5) Wo 20) 30) r —tmAl --►�'— .Af 6933up13Af Current UB1210001XSA121000A discharge characteristics (25 °C/77 °F) In s 12 11 78 10 C 9 a 1 j I , , , , L 1 2 9 s 10 20 3) a3 2 .1 s 10 . 3I) Ar I• f 6933uplCtif DIscharge T,me 1 UB121000 (XSA121000A) Diagrams • Nominal voltage: 12 V. • Nominal capacity (20 hr): 100.0 AH. • Dimensions: total height 221 mm (8.70 "); container height 214 mm (8.43 "); length 329 mm (12.95 "); width 172 mm (6.77'). • Weight: approximately 34.00 kg (74.8 Ibs). • Container material: UL94HB ABS, UL94V -0 ABS. • Internal resistance (25 °C, 777): — 6.5 m. • Discharge capacity under different temperatures: 40 °C: ^- 102% 25 °C: 100% 0 °C: — 85% - - — • Capacity 25 °C/77'F: 20 hr @ 5.0 A: 100.0 AH. 5 hr @ 16.0 A: 80.0 AH. 1 hr @ 60.0 A: 60.0 AH. 1 C @ 100.0 A: 50.0 AH. • Charging voltage (25 °C, 77 °F): Standby use: 13.65 V t 0.15 V. Cycle use: 14.7 V t 0.3 V. • Maximum discharge current: 600 A (5 sec). • Maximum charging current: 30 A. • Self- discharge residual capacity (25 °C, 77 °F): After 3 months: — 90 %. After 6 months: — 82 %. After 12 months: — 70 %. Page 8 of 10 — DF- 52397:A • 12/29/06 UPG Summary Diagrams Summary discharge characteristics w 0 1 2 + s - -- -- - OAC 0.25C 0.17C 0.09C 0.05C •% 3C 2C ,C — w• f— minutes hours I 6933up15 —f DISCHARGE TIME Summary discharge current vs. time curve (25 °C/77 °F) M — jr —' - --- t qj' 1 w' = i an -- =T - --+ N 3o _ - -. 4 O 20 i � Ir 1 t0 I I � I I I 0 200 507 1 2 3 10 Is 20 y .0 1W TU mA --- Amperes DISCHARGE CURRENT ��L•Z Ai iTly1 Same specifications as previous Jolt models; packaging and part numbers are the only changes. Charging Procedure: UPG Battery 6933uheh thl DF- 52397A • 12/29/06 — Page 9 of 10 Temperature Maximum Charging time 0.1 CA, Charging compensation charging 25 °C h ) ( Application Charging method voltage at coefficient of current cur e' Temp ( °C) 100% 50% 25 °C (V /cell) charging voltage (CA) (mVi C /cell) discharge discharge For standby Constant voltage and 2.25-2.30 — 3 ' 3 0.3 T z 24 T 2:20 power source constant current charging (with current ( -1.8 rnVF /cell) 0 — 40°C (32 — 104 °F) For cycle _ 5 service restriction) F2.40 — 2.50 (-2.8 mV/°F /cell) 0.3 16 < T < 24 10 < T < 24 Temperature compensation of charging voltage is not needed Men using the batteries within 5 °C to 35°C range. DF- 52397A • 12/29/06 — Page 9 of 10 Fire•Lite@ Alarms is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. @2006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ' O 9oo This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. IN NE91N0 i MR11F#CHNNB All specifications are subject to change without notice. QQAurr SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699A105. www.firelite.com Page 10 of 10 — DF- 52397:A • 12/29/06 DITEK's MRJ31XSCPWP protects fire and security system dialer circuits. This point of use surge protector can be easily installed in -line. DTK- MRJ31XSCPWP Product Features • Protects dialer circuit • RJ31X connection with external grounding screw • Multi- stage, hybrid design provides the best possible protection • Automatic reset to protect against repeated surges Specifications Agency Approvals:UL497A Connection Method: RJ31X In /Out, 8 pins Max Continuous Current: 150 milliamps Peak Surge Current:: 9,000 Amps Protection Modes: Pin 4 — Ground, Pin 5 — Ground Operating Temperature: -40 °F - 158 °F ( -40 °C - 70 °C) Maximum Humidity: 95% non - condensing -Dimensions: 1.7" x 3.0" x 1.2" - - - - (43mm x 76mm x 30mm) Weight: 4oz (113g) Housing: ABS Warranty: Ten Year Limited Warranty DTK -MRJ31XSCPWP Performance Data DTK- MPJ31XSCPWP Alarm Dialer Surge Protection DITEK General Product Specifications DITEK's MRJ31XSCPWP protects fire and security system dialer circuits. This point of use surge protector can be easily installed in -line. DTK- MRJ31XSCPWP Product Features • Protects dialer circuit • RJ31X connection with external grounding screw • Multi- stage, hybrid design provides the best possible protection • Automatic reset to protect against repeated surges Specifications Agency Approvals:UL497A Connection Method: RJ31X In /Out, 8 pins Max Continuous Current: 150 milliamps Peak Surge Current:: 9,000 Amps Protection Modes: Pin 4 — Ground, Pin 5 — Ground Operating Temperature: -40 °F - 158 °F ( -40 °C - 70 °C) Maximum Humidity: 95% non - condensing -Dimensions: 1.7" x 3.0" x 1.2" - - - - (43mm x 76mm x 30mm) Weight: 4oz (113g) Housing: ABS Warranty: Ten Year Limited Warranty DTK -MRJ31XSCPWP Performance Data I ISO u1 9001 -2000 L• a IR n�,',_ LISTED One DITEK Center 1- 800 - 753 -2345 Direct: 727 - 812 -5000 Doc. Number: SPS- 100065 -001 Rev 2 6 -08 1720 Starkey Road Technical Support: 1- 888 - 472 -6100 ©2008 DITEK Corp. Largo, FL 33771 www.ditekcorp.com Specification Subject to Change Service Voltage MCOV DTK- <105V AC 130V AC MRJ31XSCPWP I ISO u1 9001 -2000 L• a IR n�,',_ LISTED One DITEK Center 1- 800 - 753 -2345 Direct: 727 - 812 -5000 Doc. Number: SPS- 100065 -001 Rev 2 6 -08 1720 Starkey Road Technical Support: 1- 888 - 472 -6100 ©2008 DITEK Corp. Largo, FL 33771 www.ditekcorp.com Specification Subject to Change DITEK's HW series of surge protection are designed and manufactured to meet the exacting standards of the life safety industry. These compact parallel mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. DTK -120HW DTK- 120/240HW DTK -240HW Product Features • Diagnostic LED indicates ground presence, system power and SPD function • Small footprint enables installation in a variety of locations • Available for popular 120V, 120/240V and 240V single -phase systems -Ten Year Limited Warranty Specifications Agency Approvals: UL 1449, 2nd Edition 2007, cUL (DTK- 120HW) IEEE Location Categories: Cat. A & Cat. B Suppressor Type: Parallel configuration, external mount Peak Surge Current: 22,500A (DTK- 120HW) 27,000A (DTK- 120/240HW) 13,500A (DTK- 240HW) Protection Modes: L -G, L -N, 1 4 Temperature Range: -40C to +85C Operating Frequency: OHz — 40OHz Dimensions: 2.9" x 1.6" x 2.1" (73.7mm x 40.6mm x 53.3mm) Weight: .51b. (227g) Housing: NEMA 4 ABS DTK -HW Series Equipment Pane / /Dedicated Circuit Surge Protector DITEK Genera/ Product Specifications DITEK's HW series of surge protection are designed and manufactured to meet the exacting standards of the life safety industry. These compact parallel mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. DTK -120HW DTK- 120/240HW DTK -240HW Product Features • Diagnostic LED indicates ground presence, system power and SPD function • Small footprint enables installation in a variety of locations • Available for popular 120V, 120/240V and 240V single -phase systems -Ten Year Limited Warranty Specifications Agency Approvals: UL 1449, 2nd Edition 2007, cUL (DTK- 120HW) IEEE Location Categories: Cat. A & Cat. B Suppressor Type: Parallel configuration, external mount Peak Surge Current: 22,500A (DTK- 120HW) 27,000A (DTK- 120/240HW) 13,500A (DTK- 240HW) Protection Modes: L -G, L -N, 1 4 Temperature Range: -40C to +85C Operating Frequency: OHz — 40OHz Dimensions: 2.9" x 1.6" x 2.1" (73.7mm x 40.6mm x 53.3mm) Weight: .51b. (227g) Housing: NEMA 4 ABS - _ 2ss• _ 'IX 811 'b -L3 412AWG LEADS 2x St.OT 25­X its' :.ONDJIT _ �I• 2.05' 14H" r,� tn• ; One DITEK Center 1- 800 - 753 -2345 1720 Starkey Road Technical Support: 1- 888 - 472 -6100 Largo, FL 33771 www.ditekcorp.com ISO 9001- 20110 C UL us Document: SPS- 100057 -001 Rev 3 08/08 ©2008 DITEK Corp. Specification Subject to Change UL Model 1449, Selection: System 2nd Ed. DTK- Voltage MCOV S.V.R. 120HW 120VAC 130V 400V 1201240HW 120/240VAC 130V/250V n/a 240HW 240VAC 250V n/a - _ 2ss• _ 'IX 811 'b -L3 412AWG LEADS 2x St.OT 25­X its' :.ONDJIT _ �I• 2.05' 14H" r,� tn• ; One DITEK Center 1- 800 - 753 -2345 1720 Starkey Road Technical Support: 1- 888 - 472 -6100 Largo, FL 33771 www.ditekcorp.com ISO 9001- 20110 C UL us Document: SPS- 100057 -001 Rev 3 08/08 ©2008 DITEK Corp. Specification Subject to Change DITEK's Low Voltage Line Protector series of signal, data and loop circuit surge protectors provide strong protection in a compact hard wire package. Applications include protection of 4 -20mA current loops, alarm panel NAC, SLC and IDC loops, and burglar alarm panels. The DTK - 2LVLPF is specifically designed to protect 24V SLC loops into the alarm panel, preventing induced surges from damaging sensitive (and expensive) control boards. Its .5 Amp fusing provides extra protection for current - sensitive fire alarm panels. DTK - 2LVLPF Product Features • Series connection, parallel function adds no resistance to loop circuits • Protects 1 or 2 pairs of SLC loops • Recommended for'legacy' Fire Alarm Control Panels NOTE: DTK - 2LVLPF Specifications Agency Approvals: UL497B Connection Method: #22410 AWG screw terminals Max Continuous Current: 500 milliamps Max Surge Current: 2,000 Amps per pair Service Voltage: 24V MCOV: 38V Clamping Voltage: 47V Protection Modes: Line - Ground (All) Operating Temperature: -40 °F - 158 °F ( -40 °C - 70 °C) Maximum Humidity: 95% non - condensing Dimensions: 1.6 "H x 3.0 "W x 1.6 "D (41 mm x 76mm x 41 mm) Weight: 4oz (113g) Housing: ABS Warranty: Ten Year Limited Warranty - Accessories =DIN -Rail Kit— Part- Number- DT-K- DR -K- - - - -- The DTK - 2LVLPF was designed to protect first generation Fire -Lite Fire Alarm Control Panels where current limiting (0.5A) was required. DITEK recommends the DTK -2MHLP product line to protect all fire alarm control panel installations where the loop current may exceed 0.5A. ISO UL US 1,g� C u..m.cne- One DITEK Center 1- 800 - 753 -2345 Direct: 727 - 812 -5000 Doc. Number: SPS- 100030 -002 Rev 2 10 -07 1720 Starkey Road Technical Support: 1- 888 -472 -6100 ©2007 DITEK Corp. Largo, FL 33771 www.ditekcorp.com Specification Subject to Change DTK- 2LVLPF A Fire Alarm Pane/ Surge Protection Genera/ Product Specifications DITEK's Low Voltage Line Protector series of signal, data and loop circuit surge protectors provide strong protection in a compact hard wire package. Applications include protection of 4 -20mA current loops, alarm panel NAC, SLC and IDC loops, and burglar alarm panels. The DTK - 2LVLPF is specifically designed to protect 24V SLC loops into the alarm panel, preventing induced surges from damaging sensitive (and expensive) control boards. Its .5 Amp fusing provides extra protection for current - sensitive fire alarm panels. DTK - 2LVLPF Product Features • Series connection, parallel function adds no resistance to loop circuits • Protects 1 or 2 pairs of SLC loops • Recommended for'legacy' Fire Alarm Control Panels NOTE: DTK - 2LVLPF Specifications Agency Approvals: UL497B Connection Method: #22410 AWG screw terminals Max Continuous Current: 500 milliamps Max Surge Current: 2,000 Amps per pair Service Voltage: 24V MCOV: 38V Clamping Voltage: 47V Protection Modes: Line - Ground (All) Operating Temperature: -40 °F - 158 °F ( -40 °C - 70 °C) Maximum Humidity: 95% non - condensing Dimensions: 1.6 "H x 3.0 "W x 1.6 "D (41 mm x 76mm x 41 mm) Weight: 4oz (113g) Housing: ABS Warranty: Ten Year Limited Warranty - Accessories =DIN -Rail Kit— Part- Number- DT-K- DR -K- - - - -- The DTK - 2LVLPF was designed to protect first generation Fire -Lite Fire Alarm Control Panels where current limiting (0.5A) was required. DITEK recommends the DTK -2MHLP product line to protect all fire alarm control panel installations where the loop current may exceed 0.5A. ISO UL US 1,g� C u..m.cne- One DITEK Center 1- 800 - 753 -2345 Direct: 727 - 812 -5000 Doc. Number: SPS- 100030 -002 Rev 2 10 -07 1720 Starkey Road Technical Support: 1- 888 -472 -6100 ©2007 DITEK Corp. Largo, FL 33771 www.ditekcorp.com Specification Subject to Change FIRELITE MS- l0UD -7 FIRE ALARM PANEL BATTERY CALCULATIONS Job Name: CVS PHARMACY STORE # 0219 3798 SOUTH ORLANDO DRIVE SANFORD, FLORIDA 32773 ALARM SUPRV. TOTAL TOTAL QTY. C'RNT. C'RNT ALARM SUPRV. FIRELITE MS- l0UD -7 FACP 1 140 80 140 80 FIRELITE ANN -80 FAAP 1 100 60 100 60 EXISTING SMOKE DETECTORS 1 10 1 10 1 EXISTING DUCT DETECTORS 3 17 1 51 3 EXISTING HORN /STROBE 1 211 0 211 0 NEW TOTAL CURRENT = 512 144 BACKUP HOURS REQUIRED IN SUPRV. = 24 BACKUP MINUTES REQUIRED IN ALARM = 5 MINIMUM SUPERVISORY AH = 3.456 MINIMUM ALARM AH = 0.042496 SUB -TOTAL = 3.498496 MULTIPLY BY 1.2 = 4.1981952 MINIMUM BATTERY AH RATING = 7.0