Loading...
HomeMy WebLinkAbout3800 Enterprise Way 09-379 (fr alarm)CITY OF SANFORD PERMIT APPLICATION RECEIVED Application # : V O 1 Submittal Date: It �01�+� r�r Nov 2008 Job Address: JC)W ���2CSr a+ 5s, L Imp Value of Work: S�Q Parcel ID: � �P l�— 3� S�C. ���U-- OS� Zoning: Historic District: Description of Work: INcQ- NU:!-,Q �FCL�_' &4C I :Nk Square Footage: Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler /Alarm Q Pool ❑ Sign ❑ Electrical: New Service - # of AMPS Addition/Alteration ❑ Change of Service ❑ Temporary Pole ❑ Mechanical: Residential ❑ Non- Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: I" of Fixtures # of Water & Sewer Lines Plumbing/New Residential: # of Water Closets Occupancy Type: Residential ❑ Commercial ❑ Industrial ❑ Construction Type: # of Stories: # of Dwelling Units: # of Gas Lines Plumbing Repair - Residential ❑ Commercial ❑ Occupancy Use Group(s): Flood Zone: (FENIA form required ) ..................................`............. ................................ ................... ....1..1...1...1....... Property Owner: 1 • C�L�C��I �,1� V ZMTO%z e`s Contractor•�C2 D reed k z 4s Address: l _i i*g t r A( U.) Address: cav'ct 2.&L C-lt'_( \PL Phone: E -mail: Phone: � � State License Number: G' col pb 1 Bonding Company: Address: i4iortgage Lender: Address: Architect/Engineer: Phone: Address: Fax: Plan Review Contact Person: Phone: Fax: E -mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK- PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVrr: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions a r ble to this pro erty that may be found in the public records of this county, and there may be additional permits required from other governmental entities sue as r. ma ag to t d ate encies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the rop o the r 're n s I n a r'r FS 713. LL t) 106 Signature of Owner /Agent Date Signature o ontractor /Agent Dat Print Owner!Agent's Nanrc Signature of Notary-State of Florida Date Owner /Agent is _ Personally Known to Me or Produced ID APPROVALS: ZONING: UTIL: FD: Special Conditions: Rev 07.07 Signature of Not - d(3Pfi D PBTF „BLA DTON rsa 7 xr 1;_ . Contractor /Agent is _ P rr IfyrvT _Produced [D � t ENG: BLDG: J CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407 -302 -2516 - FAX # 407 -302 -2526 DATE: BUSINESS NAME / PROJECT: ADDRESS:3$oci G,- 411 &JLQy PHONE NO.:4,)7- yly- (o(v(o-7 FAX NO.: PERMIT #: CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] . PLANS REVIEW F. A. [ J F. S. [ ] HOOD [ ] PAINT BOOTH [ ] BURN PER I ] TENT PERMIT J TANK PERMIT [ 1 OTHER [ ] TOTAL FEES: $ -7 •O7 (PER UNIT SEE BELOW) COMMENTS: Address _ /_Bldg. # / Unit # Sauare Footaee 2. 3. 4. 5. 6. 7. 8. 9. 10. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees per Bldg; / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, Fl. 32771 Phone # -407- 330 -5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. C9 - Sanfo ire Pr vention Division Applicant's Signature OWNED BIKER SYSTEMS November 11, 2008 To: City Of Sanford To Whom It May Concern: Life Safety Systems CCTV Sound Card Access Security Clocks I, Gregory Thomas license number EF0001061, hereby authorize the following people to purchase and retrieve permits on my behalf as authorized agent(s). I understand that I am responsible for any work performed by my agent(s). E. Mark Storm Don Stewart Rick Myatt Daryl Fetterhoff Steven Stroud Sincerely, Gregory D. Thomas Personally known, sworn and subscribed tome, this ( I day of Notar Public tlNnnllnKRISTEN nEATON nj;q(�f�ln'None& Comm# DD0758459 Expires 6/9/2012 ft ida IVotaryAssn., Inc f4en o!C9oovl000nlnn uslnso In Nelson lll■ go..0� 8621 E. Dr. MLK Jr. Blvd. * Tampa, FL 33610 * Phone 813.621.7131 * Fax 813.621.8894 l ) OF ORLANDO ADUAACED EAGIAEERED 54STEAlS Life Safety Systems CCTV Sound Card Access Security Clocks Fire Mar- n System Protect: North Park Commerce Center Bldg 300 E9ectricaQ Contractor: Rogers Electric 5903 Hampton Oaks Pkwy Tampa, FL 33610 Egu. i Up, I ent a 2pp11 e Advanced Engineered Systems 3904 Corporex Park Drive Tampa, Florida 33619 E1=- 0001061 Contact: Josh Peacock 1 -800 -653 -2372 813- 621 -7131 652 Florida Central Parkway ❖ Longwood, FL 32750 ❖ Phone: 407 - 478 -4955 ❖ Fax: 407 - 478 -4958 3904 Corporex Park Drive ❖ Suite 102 ❖ Tampa, FL 33619 ❖ Phone: 813 -621 -7131 ❖ Fax: 813 -621 -8894 1 � ��003 -2019 HIL.LSBOROUGH COUNTY BUSINESS. TAX. RECEIPT EXPIRES 9.3.0 -2009 FOLIONO. FACILITIES OR NWHINES ROOMS - SEATS' ' EMPLOYEE$ . 0 0 , 0 1 RENEWAL 291:70:Q000 tl. WASTE TAX OCC. CODE. BUSINESS TYPE SURCHARGE 090.000 CONTRACTOR ALARM .., 40.00 18.00 WSINESS, 8621 E DR MARTIN L KING JR BLVD LOCATION TAMPA 33610 NAME THOMAS GREGORY MAILING Aj3VANCEt] ENGINEERED. SYS.TEMS:CORP ADDRESS 8621 E DR MARTIN L.KINO JR BLVD: TAMPA EL 336iO BUSINESS 11 A R E Q ED l 13`°3`. ` DOUG-BELDEN, TAX COt I.ECTOR- PAID -.2Q630 - 85 .08/29/2008 58.00,: I IA5 f IERCDY PAID A PRIVILEGE-= TG ENGAGE S3T3- 63x•5200 IN BUSINCSS, PROFESSION, OR OCCUPATION' SPECIFIED HEREON. 7fii$ 6F:C(71;7k.$. A 'fAX REC rIlyT VJI•I EN �JALIOAT�D. FIRE ALARM NARRATIVE: Installation of New Fire Alarm Control Panel and new fire alarm equipment to monitor the sprinkler system and protected space. FIRE ALARM SYSTEM QTY TYPE DESCRIPTION 1 NFW -50 Notifier addressable fire alarm control panel w/ 2 NAC circuits & built -in DACT. Notifier provided backbox. 9 NOT- BG12LX Notifier addressable manual pull stations. Mounts to electrical contractor provided 4" square 2 -1/8" deep box. Notifier ceiling mounted addressable photoelectric smoke 2 NP -100 detector w/ B350LP mounting base. Mounts to an electrical contractor provided 4" octagon box. 4 NMM -100 Notifier addressable monitor module. For fire pump monitoring. Mounts to a contractor provided 4" square 2 -1/8" deep box. Notifier addressable monitor module. For fire pump tamper 1 NMM -100 switch monitoring. Mounts to a contractor provided 4" square 2- 1 /8" deep box. Notifier addressable dual monitor module. For sprinkler system 3 NDM -100 monitoring. Mounts to a contractor provided 4" square 2 -1/8" deep box. 9 P2R Notifier wall mounted horn /strobe. Mounts to an electrical contractor provided 4" square 2 -1/8" deep box. 1 DTK -120HW Ditek 120 VAC Surge Protector PLEASE REFER TO ATTACHED DATA SHEETS FOR ADDITIONAL INFORMATION DN- 7102:A • Al -60 fr Arden - _ Intelligent Addressable FACP with Built -in Communicator by Honeywell ..........:.. Features Listed to UL Standard 864, 9th edition. • Auto - program (learn mode) reduces installation time. Reports two devices set to the same address. • On -board DACT • 20 software zones. • Two independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits. • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. • Remote Acknowledge, Silence, Reset and Drill via address - able monitor modules. • Two programmable relays and one fixed trouble relay. • Integral 80- character LCD display with backlighting. • Real -time clock/calendar with automatic daylight savings control. • History file with 500 event capacity. • Detector sensitivity test capability (NFPA 72 compliant). • Maintenance alert warns when smoke detector dust accu- mulation is excessive. • One person audible or silent walk test with walk -test log and printout. • Point trouble identification. • Waterflow (nonsilenceable) selection per monitor point. • System alarm verification selection per detector point. • PAS (Positive Alarm Sequence) and Pre - signal per point (NFPA:72 compliant). • Up to eight ANN -BUS annunciators. SLC COMMUNICATION LOOP; • Sindle addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. • 50 addressable device capacity (any combination of addressable detectors and modules). n • Compatible with NOTIFIER FireWarden addressable devices (refer to the FireWarden SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS); • Two independently programmable output circuits. Circuits can be configured for the following outputs: – Style Y (Class B) – Style Z (Class A) – Door Holder Service – Aux Power Source • Silence Inhibit and Autosilence timer options. • Continuous, March Time, Temporal or California. code for main circuit board NACs with two -stage capability. • Selectable strobe synchronization per NAC. • 2.5 A total power for NACs. NOTE. Maximum or total 24VDC system power shared between all NAC circuits and the ANN -BUS is 2.7 A. PROGRAMMING AND SOFTWARE. • Autoprogram (learn mode) reduces installation time. • Custom English labels (per point) may be manually entered or selected from an internal library file. • Two programmable Form -C relay outputs. • 20 software zones. • Continuous fire protection during online programming at the front panel. • Program Check automatically catches common errors not linked to any zone or input point. DN- 7102:A • 04/09/07 — Page 1 of 4 a User interface LED INDICATORS • AC Power (green) • Fire Alarm (red) • Supervisory (yellow) • Trouble (yellow) • Alarm Silenced signals (yellow) KEYPAD • 16 key alpha- numeric pad. • Acknowledge /Step • Alarm Silenced • Drill (Manual Evacuate) • Reset (lamp test) Ordering Options NFW- 50(E): Combination DACT /Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag con- taining screws, cables, key, etc., manual. NFW -50R: Same as NFW -50, with red backbox and door. DP- 510508: Optional dress panel for the FireWarden -50. TR -CE -B: Trim Ring for semi -flush mounting. BB -26: Battery backbox, holds up to two 25 Aid batteries and CHG -75. NFS -LBB: Battery box, houses two 55 Aid batteries CHG -75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH. BAT Series: Batteries, see data sheet DN -6933. PRT /PK- CABLE: Cable printer /personal computer interface cable. PRN -6: UL listed compatible event printer. Uses tractor -fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trou- ble LED. COMPATIBLE ANNUNCIATORS N- ANN -80: Remote LCD annunciator mimics the FACP dis- play N- ANN -1 /0: Input/Output Module for driving graphic annunci- ators or relays N- ANN -S /PG: Serial /Parallel Printer Interface module for con- necting printer to FACP ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI -100: Addressable low - profile ionization smoke detector. NP -100: Addressable low - profile photoelectric smoke detec- tor. NP -100T: Addressable low - profile photoelectric smoke detec- tor with thermal sensor. NH -100: Fast - response, low - profile heat detector. NH -1008: Fast - response, low- profile heat detector with rate - of -rise option. ND -100: Photoelectric low -flow duct smoke detector. Page 2 of 4 — DN- 7102:A • 04/09/07 ND -1008: Photoelectric low -flow duct smoke detector with relay option. NMM -100: Addressable Monitor Module for one zone of nor- mally -open dry- contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM -100: Dual Monitor Module. Same as NMM -100 except it - provides two Style B (Class B) only IDCs. NMM -10013: Miniature version of NMM -100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM -100: Similar to NMM -100, but may monitor up to 20 con- ventional two -wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC -100: Addressable Control Module for one Style Y/Z (Class B /A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC -1008: Addressable relay module containing two isolated sets of Form -C contacts, which operate as a DPDT switch, Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT BG12LX: Addressable manual pull station with interface module mounted inside. N100 -ISO: Fault Isolator Module. SMB500: Used to mount all modules except the NMM -100P. NZM- 100 -6: Six -zone interface module. Mount one or two modules in a BB -XP cabinet (optional). Mount up to six mod- ules on a CHS -6 chassis in a CAB -3 /CAB -4 series cabinet. NOTE: For more information on Compatible Addressable Devices for use with the FireWarden -50, see the following data sheets (document numbers): N1004SO (DN- 6994), NP- 100 1NP -100T (DN- 6995), NI -100 (DN- 6996), NH- 100 1NH -100R (DN- 6997), ND- 100 1ND -100R (DN- 7006), NMM- 100 /NMM -100P /NDM - 100 /NZM- 100 (DN- 6999), NC- 100 1NC -100R (DN- 7000), and NOT- BG12LX (DN- 7001). ADDRESSABLE DEVICE ACCESSORIES End -of -Line Resistor Assembly (R-47K and R- 3.9K): 47k ohm supervises the NMM -100, NDM -100, NMM -100P, and NC -100 module circuits. 3.9k ohm End -of -Line Resistor assembly supervises the NZM -100 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4 -wire smoke detectors and notification appliances. N -ELR Mounting Plate: Single End -of -Line resistor plate required for use in Canada. Wiring € eapilr6l eats While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical inter- ference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the following table to determine the specific wiring requirements for the SLC. (Refer to the panel manual for complete details.) CIRCUIT CONNECTIONS WIRE REQUIREMENTS - Circuit Type Circuit Function Wire Type and Limitations Recommended Max. Distance Wire Gauge and Compatible Brands Feet (meters) 12 AWG (3.25 mm2): Genesis 4410, Signal 98230, Belden 9583, WPW999 14 AWG (2.00 mm2):Genesis 4408 & 4608 Twisted, shielded pair Signal 98430, Belden 9581, WPW995 40 ohms maximum per 10,000 (3,000 m) 16 AWG (1.30 mm2): Genesis 4406 & 4606 length of Style 6 and 7 8,000 (2,400 m) Signal 98630, Belden 9575, WPW991 loops. 40 ohms per branch 4,875 (1,450 m) Direct Burial Cable Isotec maximum for Style 4 loops 3,225 (980 m) NP713110VNQ -S 18 AWG (0.75 mm2): Genesis 4402 & 4602 Connects to Signal 98300, Belden 9574, WPW975 . SLC loop Addressable Direct Burial Cable Isotec (power - limited) Devices NP714110VNQ -S 12 AWG (3.25 mm2): Belden 5020UL & 6020UL, Genesis WG -4315 & WG -4515 Twisted, unshielded pair 10,000 (3,000 m) 14 AWG (2.00 mm2):Belden 5120UL & 40 ohms maximum per length of Style 6 and 7 8,000 (2,400 m) 6120UL, Genesis WG -4313 & WG -4513 loops. 40 ohms per branch 4,875 (1,450 m) 16 AWG 1 30 2 ( mm ): Belden 5220UL & maximum for Style 4 loops 3,225 (980 m) 6220UL, Genesis WG -4311 & WG -4511 18 AWG (0.75 mm2); Belden 5320UL & 6320UL, Genesis WG -4306 & WG -4506 Untwisted, unshielded 3,000 (900 m) 12 -18 AWG (3.25 - 0.75 mm2) using listed pair wire ANN-BUS onnects to Twisted, shielded pair with (EIA -485) annunciator mod- a characteristic imped- 6,000 (1,800 m) 18 AWG (0.75 mm2) (power- limited) ules ance of 120 ohms EIA -232 Connects to (power - limited) remote PC com- Twisted, shielded pair 50 (15 m) 18 AWG (0.75 mm2) minimum puter Maximum loop wire resis- monitor module (power - limited) Initiating Device Circuit tance is 40 ohms for the MMF -300 and 20 ohms for 2,500 (760 m) 12 -18 AWG (3.25 - 0.75 mm2) the MMF -301 No more than a 2.4 volt monitor module (power - limited) Initiating Device Circuit drop allowed at end of cir- cuit. Maximum loop wire 2 500 (760 m) 12 -18 AWG 3.25 - 0.75 mm ( ) resistance is 25 ohms control module Notification Appli- In alarm, no more than a Distance limitation set by 1.2 volt (power - limited) ance Circuit volt drop allowed at maximum line 12-18 AWG (3.25 - 0.75 mm2) en end of circuit drop 1) When using untwisted, unshielded wire, full conduit is recommended for optimum EMI /RFI protection. DN- 7102:A • 04/09/07 — Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity • Intelligent Signalling Line Circuits ......... ..............................1 • Addressable device capacity ............... .............................50 • Programmable software zones ............ .............................20 • Annunciators ........................................ ..............................8 Electrical Specigications AC Power: FireWarden -50: 120 VAC, 60 Hz, 0.3 A. FireWar- den-50E: 240 VAC, 50 Hz, 0.15 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower - limited, supervised. Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger Capacity: 7 -18 AH (FireWarden -50 cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power - limited. Notification Appliance Circuits: Terminal Block provides connections for two NACs, Style Y (Class B) or. Style Z (Class A). Special Application power. Power - limited, supervised cir- cuitry. Maximum signaling current per circuit: 2.5 A. End -of- Line Resistor: 4.7 kohm,' /z watt (P /N 71252 UL listed) for Style Y (Class B) NAC. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive).. Form -C relays, nonpower - limited, nonsupervised. Cabinet spec ffications Door: 19.26" (48.92 crn.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR -CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. SWppinq Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) , high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Badges This system meets NFPA requirements for operation at 0 — 49 °C/32 — 120 °F and at a relative humidity 93% ± 2% RH (noncondensing) at 32 °C ± 2 °C (90 °F ± 3 °F). However, the Useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27 °C /60 — 80 °F. 6UFFA Standards The FireWarden -50(E) complies with the following NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). Agenda Listings and Appr®vais The listings and approvals below apply to the basic FireWar- den-50 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL: S635 • FM approved • CSFM: 7165- 0028:239 NOTIFIER@, FireWarden®, and System Sensor@ are registered trade- marks of Honeywell International Inc. Microsoft@ and Windows@ are regis- tered trademarks of the Microsoft Corporation. @2007, by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 0 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. ° We cannot cover all specific applications or anticipate all requirements. ENRINEERINR G RIANUFUTHINR All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 4 of 4 — DN 7102:A • 04/09107 h • r Addressable. Manual Pull Station DN- 7001:A • Al -380 00 H, 07 V F P F. R9 by Honeywell Tr 71 General » The Notifier NOT- BG12LX is a state -of- the -art, dual- action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels. Because the NOT- BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built -in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG /3.25 mmz wire). • Can be surface mounted (with SB -10 or SB -1 /0) or semi - flush mounted. Semi -flush mount to a standard single - gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual- action design. • Meets ADAAG controls and operating mechanicsms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable LEXANO (or polycarbonate equivalent) with a textured finish. specif! cations • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. • Maximum SLC loop current: NA. • Ambient Temperature: 32 °F to 120 °F (0 °C to 49 °C) • Relative Humidity: 93% t 2% RH (noncondensing) at 32 °C t 2 °C (90•F t 3 °F) • For use indoors in a dry location Installation The NOT-BG12LX will mount semi -flush into a single -gang, double -gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB -10 or SB -1 /0 sur- face backbox. If the NOT-BG12LX is being semi -flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). The NOT- BG12LX Addressable Manual Pull Station Operation Pushing in, then pulling down on the handle causes it to latch in the down /activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle;.,clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 — 99 on FireWarden- 1.00 -2, 1 — 50 for FireWarden -50). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non - coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red - colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover..The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be §uitable for surface mounting on matching backbox SB -10 or SB -I /O; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national /local requirements. Manual Stations shall be Underwriters Laboratories listed. c�.»�•r�n.�r��= �°^��:•�:c��x -•,tee �s>: saL�. ;�- .c��a��.�:�,�r�:r�.a�s;.�t�. DN- 7001:A • 02/05/2008 — Page 1 of 2 Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send'data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Enformation NOT- BG12LX: Dual- action addressable pull station. Includes key locking feature. SB -10: Surface backbox; metal. SB -1 /0: Surface backbox; plastic. i L J Back of station without door Terminal Connections: 1 SLC ( -); 2 SLC ( +) 13G12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S692 • MEA: 67 -02 -E Vol. IV • CSFM:7150- 0028:199 • FM Approved Detail of . � `' { BREAKAWAY TAB . �r 8 1415 0 1 f t`. <'_iS ...__1 e 1 Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. 12 3 --._... + 3 (#2 4 C , 4 15 8 7 i i t I 9 5 :_...._:_..r ........._: A Wa ROTARY DECIMAL SWITCHES I *Do not remove tab. Notifier@ is a registered trademark of Honeywell International Inc. LEXANO is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2008 by Honeywell InternatiQnal Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. - - -K EEM .. _ We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 2 of 2 — DN- 7001:A • 02/05/2008 ........ ... �0 Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. 12 3 --._... + 3 (#2 4 C , 4 15 8 7 i i t I 9 5 :_...._:_..r ........._: A Wa ROTARY DECIMAL SWITCHES I *Do not remove tab. Notifier@ is a registered trademark of Honeywell International Inc. LEXANO is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2008 by Honeywell InternatiQnal Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. - - -K EEM .. _ We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 2 of 2 — DN- 7001:A • 02/05/2008 -.,. R June 15, 2005 g by Honeywell GENERAL The NP -100 and NP -100T addressable, low- profile plug - in photoelectric detectors use a state -of -the -art photoelec- tric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden- 10OAddressable FireAlarm Con- trol Panel (FACP). The NP -100T adds thermal sensors that will alarm at a fixed temperature of 135 °F (57 0C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P /N RA40OZ). ATURES SLC loop: • Two -wire loop connection. • Unit uses base for wiring. Addressing: • Addressable by device, • Direct Decade 01 – 99 (FireWarden -100) entry of ad- dress. Architecture: • Unique single- source, dual- chamber design to respond quickly and dependably to a broad range of fires. • Sleek, low- profile design. • Integral communications and built -in type identification. • Built -in tamper- resistant feature. • Removable cover and insect- resistant screen for simple field cleaning. Operation: • Withstands air velocities up to 4,000 feet- per - minute (20 m /sec.) without triggering a false alarm. • Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. • Visible LED "blinks" when the unit is addressed (com- municating with the fire panel) and latches on in alarm. Mechanicals: * Sealed against back pressure. ® Direct surface mounting or electrical box mounting. ® Mounts to: single -gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring — included). Other system features: Fully coated circuit boards and superior RF /transient DN -6995 e Al -310 1 NP-1 00 and NP-1 OOT Addressuble Photoelectric Detectors Section: Addressable t C M - California State Fire ; , Marshal <�M> u 7272 - 002 U LISTED -- - -� APPROVED S1115 MARYLAND C State Fire Marshal 243-02 -E Vol. II Permit # 2173 NP -1017 protection. • 94 -VO plastic flammability rating. • Low standby current. Options. ® Remote LED output connection (P /N RA40OZ). SPECIRCATIONS Voltage range: 15 – 32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched "ON "). Air velocity: 4,000 ft. /min. (20 m /sec.) maximum. Diameter: 6.1" (15.5 cm) installed in 871OLP base. Height: 2.1" (5.33 cm) installed in B71OLP base. Weight: 3.6 oz. (102 g). Operating temperature range: for NP -900: 0 °C to 49 °C (32 °F to 120 0F); for NP -9007: O °C to 38 °C (32 °F to 1 OWF). Temperature: 0 °C – 49 °C (32 °F – 120 "F). Relative humidity: 10 %– 93 %, non - condensing. This document is riot intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 i 1 z DN- 6995.06115/05 — Page 1 of 2 Use photoelectric, detectors in life- safety applications to provide a broad range of fire - sensing capability, espe- cially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. These detectors are constructed of off -white LEXANO. NP- 100(T) plug -in, low - profile smoke detectors are de- signed to commercial standards and offer an attractive appearance. LEXlANO is a registered trademark of GE Plastics, a subsidiary of General Electric Company. f I +_i 11 NP- 100(T) plug -in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1,5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0" (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single -gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -tine resistors are not required. Miring 'T- taps" or branches are permitted for Style 4 (Class B) wiring. Each NP- 100(T) uses one of 99 possible addresses on the FireWarden -100 Signaling Line Circuit (SLC). It re- sponds to regular polls from the system and reports its type and status. The NP- 100(T) addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet - per - minute (20 m /sec.) with- out sending an alarm level signal. Because of its unipo- lar chamber, the NP- 100(T) is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. Each detector can have its sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed /connected to a FireWarden -100 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden -100 for record keeping. Page 2 of 2 - DN -6995 •06/15/05 PRODUCT LENE INFORMATION NP -100 Addressable photoelectric detector; B71OLP base included.* NP -100T Same as NP -100 but with thermal element; B71OLP base included." R/A404Z Remote LED. Mounts to a single -gang box. B714LP Plug -in detector base. Dimensions. 6.1" (15.5 cm). Mounting. 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single -gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). 8224RB Plug -in System Sensor relay detector base. Diameter: 6.2" (15.75 em). Mounting: 4.0" (10.16 cm) square box with or without plas- ter ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224BI Plug -in System Sensor isolator detector base. Maximum 25 devices between isola- tor bases (see DN- 6994). Diameter. 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B5018H Plug -in System Sensor sounder detector base. Diameter. 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). 'Prior to 03128105, the B71OLP base was sold separately. ectr 0ert° Advance Selectable Output Notification Appliances General System Sensor@ SpectrAlert® Advance selectable- output horns, strobes and horn /strobes are rich with features guaran- teed to cut installation times and maximize profits. The SpectrA- lert Advance series of notification appliances is designed to simplify your installations, with features such as: plug -in designs, instant feedback messages to ensure correct installa- tion of individual devices, and eleven field- selectable candela settings for wall and ceiling strobes and horn /strobes. More specifically, when installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octa- gon, or double -gang junction box. The two -wire mounting plate attaches to a single -gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe, or horn /strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- uct's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: • 12 or 24 volts. • At 24 volts, 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or 185 candela by way of a rear - mounted slide switch and front viewing window. • Horn tones and volume by way of a rotary switch. • The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn /strobes (two -wire and four -wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between —40 °F and 151 of (-40 °C and 66 °C) in wet or dry applications. Models available: • Indoor wall- mount: horn, strobe, 2 -wire horn /strobe, 4 -wire horn /strobe. • Indoor ceiling- mount: strobe, 2 -wire horn /strobe, 4 -wire horn/ strobe. • Outdoor wall- mount: horn, strobe, 2 -wire horn /strobe, 4 -wire horn /strobe. • Outdoor ceiling- mount: strobe, 2 -wire horn /strobe, 4 -wire horn /strobe. Features • Plug -in design. • Same mounting plate for wall- and ceiling -mount units. • Shorting spring on mounting plate for continuity check before installation. • Captive mounting screw. • Tampt;r- resistance capability. • Fie ld - selectable "candela settings on wall and ceiling units: 15, 15175, 30, 75, 95, 110, 115, 135, 150, 177, 185. • Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela. • Outdoor wall and ceiling products. • Outdoor products rated from —40 °F and 151'F (-40 °C and 66 °C). a F t N DN- 7087:A • J -70 �. Ll by �,Atoneywell 7087oho1Jon 7087pho2jpg Indoor Ceiling Horn /Strobe 7087phoe.jpg 7087pho4.jpg 7087pho5.Jpg 7087pho5.lpg r� 1 Indoor Wall Horn Outdoor Wall Strobe • Minimal intrusion into the backbox. • Horn rated at 88+ dbA at 16 volts. • Rotary•switch for tone selection. • Three horn voluinie settings. Electrically compatible with existing SpectrAlert products. Engineering Specifications SpectrAlert Advance horns, strobes, and horn /strobes shall mount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm) backbox, 4.0" (10.16 cm) octagonal backbox, or a double -gang backbox. Two -wire products shall also mount to a single -gang 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A uni- versal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall ter- minate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitM Module accessory, shall be powered from a non -coded notification appli- ance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate; between V\ and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 °F and 120 °F (0 °C and 49 °C) from a regulated. DC, or full- wave - rectified, unfiltered power supply. Strobes and horn /strobes shall have field- select- able candela settings including 15, 15175, 30, 75, 95, 110, 115, 135, 150, 177, 185. DN- 7087:A • 10/18/06 — Page 1 of 4 STROBE The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-sig- naling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associ- ated lens /reflector system. HORN /STROBE COMBINATION The horn /strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn /strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. The horn shall have three audibility options and an option to switch between a Temporal 3 pattern and a Non - Temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn /strobe models shall operate on a coded or non -coded power supply. OUTDOOR PRODUCTS SpectrAlert Advance outdoor horns, strobes and horn /strobes shall be listed for outdoor use by UL and shall operate between -40 °F and 151 °F ( -40 °C and 66 °C). The products shall be listed for use with a System Sensor outdoor /weatherproof backbox with half -inch and three - fourths -inch conduit entries. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync-Circuit listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at Temporal 3. Also, while operating the strobes, the mod- ule shall silence the horns on horn /strobe models over a single pair of wires. The module shall mount to a 4.688" x 4.688" x 2.125" (11.906 x 11.906 x 5.398 cm) backbox. The module shall also control two Style Y (class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy - chaining two or more synchronization modules together will syn- chronize all the zones they control. The module shall not oper- ate on a coded power supply. Strobe Current Draw, UL. Maximum (mA RMS) Candela Standard Candela Range High Candela Range 15 8 -17.5V 16 -33V 16 -33V FWR 55 DC 123 FWR 128 DC 66 FWR 71 15/75 142 148 77 81 30 NA N/A 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 135 NA NA NA NA 210 228 205 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Operating Specifications • Standard operating temperature: 32 °F to 120 °F (0 °C to 49 °C). • K Series operating temperature : -40 °F to 151'F (-40 °C to 66 °C). • Humidity range: 10% to 93% non - condensing (indoor products). • Strobe flash rate: 1 flash per second. • Nominal voltage: regulated 12 VDC /FWR or regulated 24 VDC /FWR. NOTE, Full Wave Rectified (FWR) voltage is a non - regulated, time- varying power source that is used on some power supply and panel outputs. • Operating voltage range: 8 V to 17.5 V (12 V nominal); or 16 V to 33 V (24 V nominal). NOTE. P, S, PC, and SC prod- ucts will operate at 12 V nominal only for 15 cd and 15175 cd. • Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 mm?). • Ceiling -mount dimensions (including lens): 6.8" diameter x 2.5" deep (17.3 cm diameter x 6.4 cm deep). • Wall -mount dimensions (including lens): 5.6" H x 4.7" W x 2.5" D (14.2 cm H x 11.9 cm W x 6.4 cm D). • Horn dimensions: 5.6" H x 4.7" W x 1.3" D (14.2 cm H x 11.9 cmWx3.3cmD). Agency, Listings and Approvals The listings and approvals below apply to SpectrAlert Advance Selectable Output Notification Devices. In some cases, certain modules may not be listed by certain approval agencies, or list- ing may be in process. Consult factory for latest listing status. • UL Listed: file S4011 (HR , HW , P2_, P4_ W WH, PC2_, PC4_ models); file S5512 (models SCR, SCRH, SC SC, SR, SRH, SW, SWH); file S3593 (SCRHK, SCRK, SRHK, SRK). • ULC Listed: file CS1099 (HRA, HRKA); file CS1089 (typi- cally "A" models, with exception of outdoor strobes). See Canadian data sheet for listings and specifications. FM approved. MEA approved: file 452 -05 -E. CSFM approved: file 7125 - 1653:186 (SCR, SCRH, SCW, SCWH, SR, SRH, SW, SWH); file 7125 - 1653:188 P2_, P4_, PC2_, PC4_ models); file 7135- 1653:189 (HR, HRK, HW; file 7300 - 1653:187 (SCRHK, SCRK, SRHK, SRK). Dorn Current Draw, UL, Maximum (mA RMS) Sound Pattern Temporal dB High 8 -17.5V 16 -33V DC 57 FWR 55 DC 69 FWR 75 Temporal Medium 44 49 58 69 Temporal Non - temporal Low High 1 38 57 44 56 44 69 48 75 Non - temporal Medium 42 50 60 69 Non - temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded 1 Low 40 46 52 50 Page 2of4— DN- 7087:A•10/18/06 •.��_..., x. °-.�„ =.,w,... ,�..� .__.,�._.._ w...._.�r_,.,...�,.a, -.� _s� au,.�_ ,.�_...�,.�_�__.�b_.. Horn and Blorn /$trobe Rotary Switch Setting Setting Repetition Rate dB Level 1 Temporal horn High 2 Temporal horn Medium 3 4 Temporal horn Normal horn -Low High 5 Normal horn Medium 6 Normal horn Low 7* Externally coded High 8* Externally coded Medium 9* Externally coded Low *NOTE: Settings 7, 8, and 9 are not available on 2 -wire horn /strobe. Horn and Horn /Strobe Outpgat (dBA) Switch Position 1 Sound Pattern Temporal dB High 8 -17.5V 16 -33V DC 78 FWR 78 DC 84 FWR 84 2 Temporal Medium 74; 74 80 80 3 Temporal Low 71 73 76 76 4 Non - temporal High 82 82 88 88 5 Non - temporal Medium 78 78 85 85 6 Non - temporal Low 75 75 81 81 7* Coded High 82 82 88 88 8* Coded Medium 78 78 85 1 85 9* Coded Low 75 75 81 81 *NOTE: Settings 7, 8, and 9 are not available on 2 -wire horn /strobe. Two-Wire Horn /Strobe, 5F'AMPARDCande @a Rang (15 - I15 cep), UL Maximum Cuarent Draw (mA RMS) Input, Sound Pattern, dB Level 8 -17.5V 16 -33V 15 15/75 15 15/75 30 75 95 110 115 DC Input, Temporal, High 137 147 79 90 107 176 194 212 218 DC Input, Temporal, Medium 132 144 69 80 97 157 182 201 210 DC Input, Temporal, Low DC Input, Non - temporal, High 132 141 143 152 66 91 77 100 93 116 154 176 179 201 198 221 207 229 DC Input, Non - temporal, Medium 133' 145 75 85 102 163 187 207 216 DC Input, Non - temporal, Low 131 144 68 79 96 156 182 201 210 FWR Input, Temporal, High 136 155 88 97 112 168 190 210 218 FWR Input, Temporal, Medium 129 152 78 88 103 160 184 202 206 FWR Input, Temporal, Low FWR Input, Non - temporal, High 129 142 151 161 76 103 86 112 101 126 160 181 184 203 194 221 201 229 FWR Input, Non - temporal, Medium 134 155 85 95 110 166 189 208 216 FWR Input, Non - temporal, Low 132 154 —80-T 90 105 161 184 202 211 Two -Wire Horn /Strobe, HIGHCandela Range (135 a 185 cd), UL Maximum Current ®raffia (mA RMS) DC Input DC, Temporal, High 16 -33V FWR Input FWR, Temporal, High 16 -33V 135 245 1 150 259 177 290 185 297 135 215 150 231 177 258 185 265 DC, Temporal, Medium 235 253 288 297 FWR, Temporal, Medium 209 224 250 258 DC, Temporal, Low DC, Non - temporal, High 232 255 251 270 282 303 292 309 FWR, Temporal, Low FWR, Non - temporal, High 207 233 221 248 248 275 256 281 DC, Non - temporal, Medium 242 259 293 299 FWR, Non - temporal, Medium 219 232 262 267 DC, Non - temporal, Low 238 254 291 295 FWR, Non - temporal, Low 214 229 256 262 8.8° dia. 7087dim1.Uf DN- 7087:A • 10/18/06 — Page 3 of 4 Ordering Information Model Description* Model Description WALL HORN /STROBES CEILING HORN /STROBES P211 2 -wire horn /strobe, standard cd, red. PC2R 2 -wire horn /strobe, standard cd, red. P2RH 2 -wire horn /strobe, high cd, red. PC2RH 2 -wire horn /strobe, high cd, red. P2RK' 2 -wire horn /strobe, standard cd, red, outdoor. ** PC2RK 2-wire-horn/strobe, standard cd, red, outdoor. P2RHK 2 -wire horn /strobe, high cd, red, outdoor. PC2RHK 2 -wire horn /strobe, high cd, red, outdoor. P21N 2 -wire horn /strobe, standard cd, white. PC2W 2 -wire horn /strobe, standard cd, white. P2WH 2 -wire horn /strobe, high cd, white. PC2WH 2 -wire horn /strobe, high cd, white. P4R 4 -wire horn /strobe, standard cd, red. PC4R 4 -wire horn /strobe, standard cd, red. P4RH 4 -wire horn /strobe, high cd, red. PC4RH 4 -wire horn /strobe, high cd, red. P4RK 4 -wire horn /strobe, standard cd, red, outdoor. PC4RK 4 -wire horn /strobe, standard cd, red, outdoor. P4RHK 4 -wire horn /strobe, high cd, red, outdoor. PC4RHK 4 -wire horn /strobe, high cd, red, outdoor. P4W 4 -wire horn /strobe, standard cd, white. PC4W 4 -wire horn /strobe, standard cd, white. P4WH 4 -wire horn /strobe, high cd, white. WALL STROBES PC4WH 4 -wire horn /strobe, high cd, white. CEILING STROBES SR Strobe, standard cd, red. SCR Strobe, standard cd, red. SRH Strobe, high cd, red. SCRH Strobe, high cd, red. SRK Strobe, standard cd, red, outdoor. SCRK Strobe, standard cd, red, outdoor. SRHK Strobe, high cd, red, outdoor. SCRHK Strobe, high cd, red, outdoor. SW Strobe, standard cd, white. SCW Strobe, standard cd, white. SWH Strobe, high cd, white. ACCESSORIES SCWH Strobe, high cd, white. HORNS BBS -2 Backbox skirt, wall, red. HR Horn, red. BBSW -2 Backbox skirt, wall, white. HRK Horn, red, outdoor. BBSC -2 Backbox skirt, ceiling, red. HW Horn, white. BBSCW -2 Backbox skirt, ceiling, white. ACCESSORIES, continued SA -WBB Weatherproof backbox, wall. MP- 2W -20BP 2 -wire indoor mounting plates, pkg of 20. SA -WBBC Weatherproof backbox, ceiling. cont'd at right MPK- 2W -20BP 2 -wire outdoor mounting plates, pkg of 20. NOTE. * "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd" refers to strobes that include 15, 15175, 30, 75, 95, 110, and 115 candela settings. *"'All outdoor models ( "K" suffix) include weatherproof backbox. Sync•CircuitTM is a trademark, and NOTIFIER®, SpectrAlert®, and System Sensor® are registered trademarks of Honeywell International Inc. 02006 by Honeywell International Inc. All rights reserved. Unauthorized use of this docuhent is strictly prohibited. =Qx a �s This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 4 of 4 — DN- 7087:A • 10/18/06 rTK-F1W Series, Equipment Panel/Dedicated Circuit .purge Protector I.. - I �#' / IDITE _ General Product Specifications DITEK's HW series of surge protection are designed and manufactured to meet the exacting standards of the life safety industry. These compact parallel mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. ®TK -120HW DTK- 1201240HW DTK -240HW Product Features • Diagnostic LED indicates ground presence, system power and SPD function • Small footprint enables installation in a variety of locations • Available for popular 120V, 120/240V and 240V single -phase systems -Ten Year Limited Warranty Specifications Agency Approvals: UL 1449, 2nd Edition 2007, cUL (DTK- 120HW) IEEE Location Categories: Cat. A & Cat. B Suppressor Type: Parallel configuration, external mount Peak Surge Current: 22,500A (DTK- 120HW) 27,000A (DTK- 120/240HW) 13,500A (DTK- 240HW) Protection Modes: L -G, L -N, N -G Temperature Range: -40C to +85C Operating Frequency: OHz — 40OHz Dimensions: 2.9" x 1.6" x 2.1" (73.7mm x 40.6mm x 53.3mm) Weight:.51b. (2278) Housing: NEMA 4 ABS , I ,i fS4" . .' s LEADS`' t z 1 One DITEK Center 1- 800 - 753 -2345 1720 Starkey Road Technical Support: 1- 888 - 472 -6100 Largo, FL 33771 www.ditel(coM.com F UL Model ` C a D0l Document: SPS- 100057 -001 Rev 3 08/08 1449, Selection: System 2nd Ed. DTK- Voltage MCOV S.V.R. 120HW 120VAC 130V 400V 1201240HW 120/240VAC 130V/250V n/a 240HW 240VAC 250V n/a , I ,i fS4" . .' s LEADS`' t z 1 One DITEK Center 1- 800 - 753 -2345 1720 Starkey Road Technical Support: 1- 888 - 472 -6100 Largo, FL 33771 www.ditel(coM.com F 901KO 01 -2000 ` C a D0l Document: SPS- 100057 -001 Rev 3 08/08 ©2008 DITEK Corp. Specification Subject to Change NON-PLENUM . . General use indoors for: m Solid bare copper � R,cunJsecuh�ya|anns m Color coded PVC insulation in Smoke detection syotems m Ke6PY[jacket m NEC article 760 m UL|ivu,6FPLK No. oF N_--- ..~—°`. .,~.. .~^.,. [S[# OnNn /wvo srnxwo Ti x Txx O.D. mS/1000' 250250 4 22 SOLID 010` .02011 .1391, 720 250302 a zu SoUo .010" ozo" .166" 24 250350 8 uz s0Uo .Olu" .ozo" .180" 36 250103° 2 lu Szuo .010" IoD" .151" /o 250110° 4 lo 5oUD o10" .020" .785" 31 zsmzo d 18 8Ouo '010" .Vun .zzr 47 250125 n 78 5ouo .010" lun" .240" 63 250128 10 18 snuo .Oln" .Oux" 29111 ra 250039° Z 18 sOun .010" .020" .182" zo ` ` Most products available esun*s 4 16 -`JOuo o10" .020" .211" r ` m boxes or reels with sequential 250017° z 14 3oUo .012" .020" .208" *v markings and ripcords 250022 4 14 s0uo .012" .025" .zos" ra 250010 2 12 SOLID .012" .025" .26011 65 250013 4 12 SOLID .012" .025" .30311 106 � � ' ^