HomeMy WebLinkAbout115 Commerce Way 09-721 SprinklerCITY OF SANFORD PERMIT APPLICATION DEC
Application # :_ o 9- Q.�- / Submittal Date: 12/30/08 02008
T
Job Address: 1 1 S C'OMMERC'E WAY, SANFORD FL Value of Work• $ 1168.00
Parcel ID: 35-19-30-524-0000-0160 ivsbt Historic District:
INSTALL HETKUD In SAND]r
rs
Description of Work: INSTALL HEADS IN STORAGE ROOM Square Footage:
Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler /Alarm ® Pool ❑ Sign ❑
Electrical: New Service — # of AMPS Addition/AIteration XX Change of Service El Temporary Pole ❑
Mechanical: Residential 13 Non-Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Cale. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets
Occupancy Type: Residential ❑ Commercial M Industrial ❑
Plumbing Repair— Residential ❑ Commercial ❑
Occupancy Use Group(s):
Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required)
.......................................................................................... ...............................
Property Owner:
Address:
Phone: E -mail:
Bonding Company:
Address:
Arch itect/Engineer:
Address:
Plan Review Contact Person:
Contractor: SOUTHERN FIRE
Address: 3801 E_ SR 46
SANFORD, FL 32771
Phone:3 2 3 4 2 0 0 State License Number? 4 0 7 2 3 0 0 01 1 990
Mortgage Lender:
Address:
Phone:
Fax:
Phone: Fax:
E -mail:
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
��'' !�'��
Signature of Owner /A ent Date Signat ure o Coractor/ ent
Date
Owner /Agent's Name
Signature of Notary-State of Florida Date
Owner /Agent is _
Produced ID
APPROVALS: ZONING:
Special Conditions:
Rev 07.07
Personally Known to Me or
UTIL: FD:
ROBERT H.
Print Contractor /Agent
boy N
ry Public State of FlorWa
arman Ramirez
6/ My COmmlSsion IDDS44434
Expires 04/30/2012
Produced ID
ENG: BLDG:
1000,0 U
Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1
http: / /www.sepafl.org/ web /re_web.seminole_county_title ?parcel =3 5193 052400000160 &... 12/23/2008
12:Aa900
-0000„
DAVID JOHNSON. CFA, ASA
PROPERTY—
13
— Y _ �� "tt i
-1
APPRAISER
12.0
"
:-
2o.A 16 , „
a1.;°
SEMINOLECOUtiTYFL.
- .—
xi ai
«�
1.1011 E. FIRST ST
'
�i',1
-
t
SANFORD. FL32771 -1468
407- 665 -7506
F
2
G
2
�
a
A2 A.5A.
4
lll`
VALUE SUMMARY
VALUES
2009
2008
Working
Certified
GENERAL
Value Method
Income
Income
Parcel Id: 35- 19 -30- 524 -0000 -0160
Number of Buildings
2
2
Owner: SHB PROPERITES LLC
Depreciated Bldg Value
$0
$0
Mailing Address: 115 COMMERCE WAY
Depreciated EXFT Value
$0
$0
City,State,ZipCode: SANFORD FL 32771
Land Value (Market)
$0
$0
Property Address: 115 COMMERCE WAY SANFORD 32771
Land Value Ag
$0
$0
Facility Name: SHB PROPERTIES,LLC
JusUMarketValue
$1,073,075•
$1,075,639 "
Tax District: S1- SANFORD
Portablity Adj
$0
$0
Exemptions:
Save Our Homes Adj
1 $0
$0
Dor: 4102- COMMERCE CENTER
Assessed Value (SOH)
1 $1,073,075 •
$1,075,639
Tax Estimator
(* Income Approach used.)
2009 TAXABLE VALUE WORKING ESTIMATE
Taxing Authority
Assessment Value
Exempt Values
Taxable Value
County General Fund
$1,073,075
$0
$1,073,075
Schools
$1,073,075
$0
$1,073,075
City Sanford
$1,073,075
$0
$1,073,075
SJWM(Saint Johns Water Management)
$1,073,075
$0
$1,073,075
County Bonds
$1,073,0751
$0
$1,073,075
The taxable values and taxes are calculated using the current years working values and the prior years approved millage rates.
SALES
Deed Date Book Page Amount Vac /lmp Qualified
WARRANTY DEED 01/2005 05605 0227 $1,137,500 Improved Yes
2008 VALUE SUMMARY
WARRANTY DEED 12/1995 03014 1141 $450,000 Improved No
2008 Tax Bill Amount: $20,377
WARRANTY DEED 0811995 02969 1799 $273,300 Improved No
2006 Certified Taxable Value and Taxes
DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS
WARRANTY DEED 06/1988 01968 0785 $117,700 Vacant No
ADMINISTRATIVE DEED 09/1987 01885 0307 $280,200 Vacant No
Find Sales within this DOR Code
LEGAL DESCRIPTION
LAND
PLATS: Pick...
Land Assess Method Frontage Depth Land Units Unit Price Land Value
SQUARE FEET 0 0 51,157 3.50 $179,050
LEG LOTS 16 17 & 18 SANFORD COMMERCE PARK PB 31
PG 67
BUILDING INFORMATION
Bid Num Bid Class Year Bit Fixtures Gross SF Stories Ext Wall Bid Value Est Cost New
1 STEEL /PRE ENG 1988 8 18,000 1 METAL PREFINISHED - INSULATED $430,748 $488,377
Subsection / Sgft CANOPY / 312
Subsection / Sgft CANOPY/ 125
2 STEEL/PRE ENG 1999 2 6,300 1 METAL PREFINISHED - INSULATED $178,132 $174,639
Subsection / Sgft CANOPY / 280
Permits
EXTRA FEATURE
Description Year Bit Units EXFT Value Est Cost New
COMMERCIAL CONCRETE DR 4 IN 1988 6,704 $6,783 $14,280
WALKS CONC COMM 1988 400 $629 $1,324
LOAD WELL 1988 1,275 $909 $1,913
NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes.
"" If you recently purchased a homesteaded property your next ears property tax will be based on Just/Market value.
http: / /www.sepafl.org/ web /re_web.seminole_county_title ?parcel =3 5193 052400000160 &... 12/23/2008
Southern Fire Protection of Orlando, Inc.
3801 E. SR 46, Sanford, FL 32771 -9155
Phone: (407) 323 -4200
Fax: (407) 328 -8931
Emergency: (407) 328 -2912
LIMITED POWER OF ATTORNEY
( CITY OF SANFORD ) Building Department
DECEMBER 30 2008
I hereby name and appoint:
STEVEN COHEN Printed Name of Appointee
Southern Fire Protection of Orlando, Inc Company Name of Appointee
To be my lawful attorney -in -fact to act for me in submitting and receiving
Commercial/Residential Permitting, and to do all things necessary to this appointment.
AMERICAN MARBLE Project Name
1 1 5 COMMERCE WAY Project Address
WITNESS ( SSATT MENDOZA )
State of Florida
Signed: (may - --
By: Robert H. 6a -dwell, Jr.
President
License 974072300011990
County of Seminole
Sworn to and subscribed before me this 3 0th day of
By Robert H. Caldwell, Jr., who is personally
Notary Public
My Commission
DECEMBER, 2008
to me
Credibility • Integrity
� r riy Notary !uotir. Sine of Florida
?
Carmen R mi,fZ
My Coli ),iss-on 00844434
�Y*FN* � Ex mires !W3012012
SOUTHERN FIRE PROTECTION OF ORLANDO, INC.
3801 EAST STATE ROAD 46
SANFORD, FLORIDA 32771 -9155
407 - 323 -4200
City of Sanford December 30, 2008
Plans Review & Inspection Dept.
Sanford, Florida
Dear Fire Plan Reviewer,
Southern Fire Protection of Orlando Inc. will be adding (6) fire sprinkler
pendants in sanding booth and storage room at American Marble which is
located at 115 Commerce Way, Sanford Florida.
Southern Fire Protection will complete this work in accordance with
N.F.P.A 13 2002 edition codes, regulations and local authorities. Southern
Fire Protection will contact your office when the work is complete for a
visual inspection.
If you have any questions please do not hesitate to call.
Sincerely,
Carmen Ramir
Operations Assistant
Southern Fire Protection of Orlando, Inc.
Product Description
The Reliable Model G Automatic Sprinkler utilizes the
center strut solder in compression principle of
construction. The fusible alloy is captured in the
cylinder of the solder capsule by a stainless steel ball.
When the fusible alloy melts, the ball moves into the
cylinder allowing the cylinder to fall away from the
sprinkler. When this happens, the lever is released to
spring free from the sprinkler so that all of the operating
parts clear from the waterway allowing the deflector to
distribute the discharging water.
Except for the parts in the cylinder as mentioned
above, the sprinkler components are made from
copper based alloys for maximum corrosion
protection. Lead plated, wax coated or wax over lead
plated sprinklers are available for specially severe
environments. Chrome plated sprinklers are available
for decorative purposes.
All sprinklers are individually hydrostatically tested.
All sprinklers are identified as to their fusing point by
markings that appear on several of the operating parts
and by an identifying color that appears on the frame.
Sprinkler Types
Standard Upright - This deflector configuration is
normally used with exposed piping installations. Water
is distributed laterally and downward in a wide pattern
approximating a hemisphere which is completely and
uniformly filled with water in the form of small drops or
spray.
Standard Pendent - This deflector configuration is
normally used where the space above the piping is
limited or where a concealed piping installation is
employed. The discharge characteristics of the
standard pendent are virtually identical to the
standard upright as described above.
Large and Small Orifice —By varying the orifice size,
a large or small orifice sprinkler is created that will
distribute as much as 40% more water or 65% less
water than the normal 1/211 (15mm) orifice sprinkler.
Conventional —This deflector configuration is used
primarily in those countries where the LPC installation
rules have precedence. The sprinkler is designed to
distribute a portion of its water discharge upward
against the ceiling with the balance downward. It may
be installed in either the upright or the pendent
position. Sprinklers with conventional deflectors are
available with orifice sizes corresponding to light,
ordinary and extra -high hazard installations.
Bulletin 110 Rev.S
Model G W
Automatic Sprinklers
Spray Upright, 1
Spray Pendent o
And Conventional CD
U)
it
.e
Upright
Small Orifice Upright
Pendent
Conventional
Application and Installation
Standard sprinklers are used in fixed fire protection
systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice sizes, temperature ratings,
deflector styles and sprinkler spacings are in
accordance with the latest published standards of the
National Fire Protection Association or the approving
authority having jurisdiction.
The sprinklers must be installed with the Reliable
Model D Sprinkler Wrench. Any other type of wrench
may damage the sprinkler.
The approvals or listings of Reliable Automatic
Sprinklers by major approving organizations are
shown in the tabulated list provided on the back of this
bulletin.
'Patent No. 4,440,234
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552
Technical Data
Temperature Ratings
"K" Factor
Maximum
Chrome
(2)
Sprinkler Identification
US
Metric
Sprinkler Type
Sprinkler—
Height
Approvals
IVumber_(SIN)
SSU
SSP
Standard – Upright (SSU) and Pendent (SSP)
°F
°C
Classification
Color
Ordinary
135
Deflectors Marked to Indicate Position
5.62
81.0
2 %" (73 mm)
1, 2, 3, 4, 5, 6,7
R1025
R1015
Y2" (15 mm) Standard Orifice with j2" NPT (RJ2) Thread
'/1 fi' (11 mm) Small Orifice with }2' NPT (R}2) Thread
%" (10 mm) Small Orifice with y" NPT (Ryy Thread
%fi' (8 mm) Small Orifice with y" NPT (RJZ) Thread
' %z' (20 mm) Large Orifice with Jz' NPT (Ry2) Thread
4.24
2.82
1.98
7.96
61.0
40.6
28.5
114.7
2' /s" (73 mm)
2 Ya" (73 mm)
2' /e" (73 mm)
2 Yee" (73 mm)
1, 3, 7
1, 2, 3, 7
1, 3, 7
1, 2, 3, 7
R1023
R1021
R1022
R1026
R1013
R1011
R1012
R1016
1 3132' (20 mm) Large Orifice with %" NPT (R %)Thread
8.20
118.2
215/,fi' (75 mm)
1, 2, 3, 7
R1027
R1017
20 mm XHH with 20 mm Thread
8.20
118.2
75.4 mm
4, 5, 6
R1027
R1017
10 mm XLH with 10 mm Thread
4.10
59.1
73 mm
4, 5, 6
R1024 I
R1014
Conventional — Installed in Upright or Pendent Position
4.10
5.62
8.20
59.1
81.0
118,2
73 mm
73 mm
75.4 mm
5
4, 5, 6
4,5
R1074
R1075
R1077
10mm XLH with 10mm Thread
15mm Standard Orifice with (R}2) Thread
20mm XHH with (R34) Thread
Temperature Ratings
(1) Frame color does not apply to painted or plated sprinklers
–Use sprinkler rating as Identified on operating parts.
Finishes0)
Maintenance
Model G Sprinklers should be inspected quarterly and the
sprinkler system maintained in accordance with NFPA 25. Do
not clean sprinklers with soap and water, ammonia or any other
cleaning fluids. Remove any sprinkler that has been painted
(other than factory applied) or damaged in any way. A stock of
spare sprinklers should be maintained to allow quick replace-
ment of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons and
packaging until used to minimize the potential for damage to
sprinklers that would cause improper operation or
non - operation. Use only the Model D Sprinkler Wrench for
sprinkler removal and installation. Any other type of wrench may
damage the sprinkler.
Standard Finishes
Bronze
Maximum
Chrome
(2)
—All Temperature Ratings
Sprinkler
Ambient
Internet Address
Only Frame and Deflector are Painted
Rating
Temperature
Frame (1)
°F
°C
°F
°C
Classification
Color
Ordinary
135
57
100
38
Black
Ordinary
165
74
100
38
Uncolored
Intermediate
212
100
150
66
White
High
286
141
225
107
Blue
(1) Frame color does not apply to painted or plated sprinklers
–Use sprinkler rating as Identified on operating parts.
Finishes0)
Maintenance
Model G Sprinklers should be inspected quarterly and the
sprinkler system maintained in accordance with NFPA 25. Do
not clean sprinklers with soap and water, ammonia or any other
cleaning fluids. Remove any sprinkler that has been painted
(other than factory applied) or damaged in any way. A stock of
spare sprinklers should be maintained to allow quick replace-
ment of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons and
packaging until used to minimize the potential for damage to
sprinklers that would cause improper operation or
non - operation. Use only the Model D Sprinkler Wrench for
sprinkler removal and installation. Any other type of wrench may
damage the sprinkler.
Standard Finishes
Bronze
—All Temperature Ratings
Chrome
(2)
—All Temperature Ratings
White
—All Temperature Ratings
Internet Address
Only Frame and Deflector are Painted
Special Application Finishes
Bright Brass Plated
—Only frame, deflector and cap are plated. 135 °F (57 °C), 165 °F
(74 °C), 212 °F (100 °C) Temp. Rating.
Black Plated
—Only frame, deflector and cap are plated. All Temp. Ratings.
Polyester Coated (2)
—Only frame and deflector are coated.
Lead Plated
—165 °F (74 °C), 212 °F (100 °C) and 286 °F (141 °C) Temp. Ratings.
Wax- Coated (3)
—165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax.
Wax- Coated Over
Lead Plated (3)
—165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax.
(1) Other colors and finishes are available. Consult factory for details.
(Z) UL listed and NYC MEA Approved only.
(3) 212 °F (100 °C) brown wax may be used on 286 °F (141 °C)
sprinklers when maximum ambient temperatures do not exceed 150 °F
(66 0C). UL Listed, FM Approved, NYC MEA 258 -93 -E.
Approval Organizations
1. Underwriters Laboratories, Inc.
2. Factory Mutual Research Corporation
3. Underwriters' Laboratories of Canada
4. Loss Prevention Council
5. Pleniere Assemblee
6. VdS Schadenverhutung
7. N.Y.C. BS &A No. 587 -75—SA or
N.Y.C. MEA 258 -93 -E
Ordering Information
Specify
1. Model G
2. Deflector
• Upright
• Pendent
• Conventional
3. Nominal Orifice
4. Inlet Thread
5. Temperature Rating
6. Finish
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual
Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc.
(800) 431 -1588
Sales Offices
(800) 848 -6051
Sales Fax
(914) 668 -3470
Corporate Offices
www.reliablesprinkler.com
Internet Address
® Red
Paper
Revision lines indicate updated or new data.
EG. Printed in U.SA. 11/04 P/N 9999970005