Loading...
HomeMy WebLinkAbout100 Towne Center Blvd 17-2175 (new constr)'A v a CITY OF SANFORD s Ztll7 BUILDING & FIRE PREVENTION ' JULPERMIT APPLICATION - Application No. Documented Construction, Value: $ $1,002,000.00 Job Address: 100 Towne Centre Blvd, Sanford, 32771 Historic District: Yes ❑ No Parcel ID: 29 19 30 504 0000 0010 Residential ❑ CommercialFX] Type of Work: New 0 Addition ❑ Alteration ❑ Repair ❑ bemo ❑ Change of Use ❑ Move ❑ Description of Work: Construct single story restaurant building. n ' r7._ Plan Review Contact Person: EX -A V i 6 S't 0 0 Ck Title:V.`10 ermmany\ Phone: Fax: Email:__ d o-vid . stcrck q u e . Property Owner Information Name Tim Barnett Phone: 502-515-7306 Street: 6040 Dutchman's Lane Resident of property? : No. City, State Zip • Louisville, KY 40205 Name TBD Street: N/A City, State Zip: N/A Contractor Information Phone: N/A Fax:`N/A State License No.: N/A Architect/Engineer Information Name: BDG Architects Phone: 813-323-9233 Street: 100 S Ashley Dr STE 100 City, St, Zip: Tampa FL 33602 Bonding Company: N/A Address: N/A Fax: 813-323-9238 E-mail• gregg.holdsworth@bdgllp.com Mortgage Lender: N/A Address: N/A WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE- BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 516 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application zi� D FLORIDA PRODUCT APPROVALS PRODUCT TYPE MANUFACTURER MODEL #/SERIES FL PRODUCT APPR. NO. EXP. DATE MIAMI DADE NOA EXP. DATE OWNER, FIXTURE, SHEET EQUIPMENT EXTERIOR DOORS OUTSWINGING COMMERCIAL DOOR STEELCRAFT H SERIES 17-0320:05 05-05-2018 OUTSWINGING COMMERCIAL DOOR STEELCRAFT H SERIES 15-0930.06 05-05-2020 SWINGING EXTERIOR DOOR ASSEMBLIES NYSTROM, INC. - FL 21058.1 N/A SWINGING EXTERIOR DOOR ASSEMBLIES SPECIAL -LITE SL -17 FL 21856.1 N/A SWINGING EXTERIOR DOOR ASSEMBLIES DETEX ADVANTEX 40 SERIES FL 19181 N/A 100 SOUTH ASHLEY DRIVE, SUITE 100 WALL PANELS STOREFRONT KAWNEER 451 FL 14287 - R4 TAMPA, FLORIDA 33602 ROOFING PRODUCTS SINGLE PLY ROOF ON WOOD DURO-LAST 50 MIL N/A 13-1106.03 AUG. 22, 2017 METAL ROOF ON WOOD METAL SALES MFG. CORP. ALUMINUM 5V -CRIMP FL 11560.1 - R2 N/A ROOF HATCH BILCO NB FL 15110.2 - R1 14-070$,07 PRE-ENGINEERED AC. STANDS PRECISION ALUMINUM PRODUCTS ALUMA STAND FL 16921,2 - R2 PHONE: 813-323-9233 EXTERIOR WALLS PHONE: 502-855-5561 (0) FAX: 813-323-9238 PHONE: 941-387-5266 (C) EMAIL: Monica.Jones@TexasRoadhouse.com AIR HANDLING UNIT FIBER CEMENT SIDING AND SOFFIT ALLURA PLANK/ PANEU SOFFIT N/A CIVIL LANDSCAPE ENGINEER 14-1022.03 1 APR. 24, 2018 OWNER & CONSULTANTS LIi-1.01 IRRIGATION PLAN EXIST EXISTING OS A ANNEALED 1 OWNER, FIXTURE, SHEET EQUIPMENT ARCHITECT STRUCTURAL ENGINEER TEXAS ROADHOUSE BDG ARCHITECTS HEES & ASSOCIATES, INC 6040 DUTCHMAN'S LANE 100 SOUTH ASHLEY DRIVE, SUITE 100 1381 FIFTH STREET LOUISVILLE, KY 40205 TAMPA, FLORIDA 33602 SARASOTA, FLORIDA 34236 CONTACT: MONICA JONES, CONTACT: GREGG HOLDSWORTH, AIA KARL F. HEES . S.I. F.ASCE CON P.E TACT: ARCHITECTURAL DESIGN MANAGER PHONE: 813-323-9233 PHONE: 941-955-4555 (0) PHONE: 502-855-5561 (0) FAX: 813-323-9238 PHONE: 941-387-5266 (C) EMAIL: Monica.Jones@TexasRoadhouse.com AIR HANDLING UNIT FAX: 941-955-9333 FIBERGLASS REINFORCED PLASTIC PTD EMAIL: Karl@heesassociates.com CIVIL LANDSCAPE ENGINEER MEHCANICAL, PLUMBING, HOOD EQUIPMENT FIRE RETARDANT TREATED ELECTRICAL ENGINEER QUARRY TILE ASPH ASPHALT LC SYSTEM, INC . BOHLER ENGINEERING EMERALD ENGINEERING, INC DUBILIN, OHIO 3820 NORTHDALE BLVD, SUITE 300B 205 NORTH ARMENIA AVENUE, STE 102 CONTACT: KEVIN MULDOON TAMPA, FLORIDA 33624 TAMPA, FLORIDA 33609 PHONE: 813-955-0300 (0) PHONE: 614-235-9430 EMAIL: KMULDOON@LC-SYSTEMS.COM CONTACT: JAMES KELLEY, PE PHONE: 813-812-4100 (0) PHONE: 813-758-9808 (C) FIXTURE PHONE: 813-955-2323 (C) EMAIL: m.costello@emeraidmep.com REFERENCE EMAIL: jkeliey@bohlereng.com CEILING HC SIGNAGE FS -2.2 POS WIRING DIAGRAM + • A-500 WALL DETAIL • + • FEDERAL HEALTH CONCRETE MASONRY UNIT HDW 6040 DUTCHMAN'S LANE STE 300 REQ'D RO REQUIRED ROUGH OPENING LOUISVILLE, KY 40205 COLUMN HM CONTACT: STEVE MAESER SB SPLASHBLOCK PHONE: 502-515-7328 CONCRETE HT EMAIL: smaeser@FederalHeaith.com SYMBOLS_ WALL TYPE ELEVATION ELEVATION DATUM TAG X ' 1 DETAIL TAG A# AlA REVISION NUMBER N FINISW FINISH TAG W A1.0 E INTERIOR ELEVATION TAG O X KEYNOTE S 1 ROOM ROOM TAG EXTERIOR ELEVATION TAG A1.0 XXX T 101 DOOR TAG A1.0 PLAN DETAIL TAG BUILDING SECTION TAG Og WINDOW TAG A1.0 ABBREVIATION LIi-1.01 IRRIGATION PLAN EXIST EXISTING OS A ANNEALED ELECTRICAL DETAILS FD FLOOR DRAIN PF AC AIR CONDITIONING FEC FIRE EXTINGUISHER CABINET PS PRIMARY SCUPPER ACT ACOUSTIC CEILING TILE FF FINISH FLOOR PSF POUNDS PER SQUARE FOOT AFF ABOVE FINISH FLOOR FR FIRE RATED PT PRESSURE TREATED AHL AIR HANDLING UNIT FRP FIBERGLASS REINFORCED PLASTIC PTD PAINTED AL ALUMINUM FRT FIRE RETARDANT TREATED QT QUARRY TILE ASPH ASPHALT GALV GALVANIZED R RADIUS KITCHEN ELEVATIONS • A-310 WALL SECTIONS • • GYP BD GYPSUM BOARD REBAR REINFORCING BAR CJ CONTROL JOINT FIXTURE A-313 WALL SECTIONS • • • REF REFERENCE CLNG CEILING HC HANDICAP FS -2.2 POS WIRING DIAGRAM + • A-500 WALL DETAIL • + • CMU CONCRETE MASONRY UNIT HDW HARDWARE REQ'D RO REQUIRED ROUGH OPENING COL COLUMN HM HOLLOW METAL SB SPLASHBLOCK CONC CONCRETE HT HEIGHT CONT CONTINUOUS HVAC HEATING, VENTILATION, AIR CONDITIONING SIM SIMILAR INSUL INSULATION SPEC SPECIFICATION CPT CARPET MAX MAXIMUM SS STAINLESS STEEL CT CERAMIC TILE MECH MECHANICAL STL STEEL CL CENTERLINE MFR MANUFACTURER STOR STORAGE DBL DOUBLE SUSP SUSPENDED DF DRINKING FOUNTAIN. MIN MINIMUM T TEMPERED DIA DIAMETER MO MASONRY OPENING TYP TYPICAL DIM DIMENSION MR MOISTURE RESISTANT UNO UNLESS NOTED OTHERWISE DN DOWN METAL VCT VINYL COMPOSITION TILE DS DS DOWNSPOUT NA N A NOT APPLICABLE VERT VERTICAL EA EACH NOT IN CONTRACT WD WOOD EJ EXPANSION JOINT NOM NOMINAL WP WATERPROOF ELEC ELECTRICAL NTS NOT TO SCALE WWF WELDED WIRE FABRIC ELEV ELEVATION OC ON CENTER EQ EQUAL OPP OPPOSITE LOCATION MAP i DRAWINGS DRAWINGS ISSUED DRAWINGS DRAWINGS ISSUED 3 4 5 e- N N > > Lh q Ln > > co d Ln > > U) GWL' 2' W U) wLL' w w' O O O w w O O O CD C/) �>>> > > > c, �C)w H0wI L)Ix Ix W H H tY lY LY W h w CO I Ix 1-- Z Z I_- Z Z Z w w 'S 'S w w wan.00o Wa.aoo0 ar- ti I- rte- 00 w .- 0- I r :° o o O a O h N N N N N r N CV N CV CV r P N N N 14 N N CCS e3 00 'SHEET# o cSHEET # SHEET NAME 0 a o SHEET NAME GENERAL PLUMBING 100 S. Ashley Dr., P: 813 - 323 - 9233 G-000 ICOVERSHEET 10101 P000 PLUMBING LEGENDS AND NOTES • Ste. 100 Lic. #: AA- 0003590 G-010 LIFE SAFETY PLAN 101*1 P101 LEVEL1 UNDERGROUND PLUMBING PLAN • • • Tampa, FL 33602 W: www.bdglip.com CIVIL P102 LEVEL1 ABOVE GROUNDPLUMBING PLAN • • C-1 COVER SHEET • P103 ROOF PLUMBING PLAN • • C-2 GENERAL NOTES 0 • P401 PLUMBING ENLARGED PLANS • C-3 SOIL EROSION CONTROL PHASE I & DEMO PLAN . • P501 PLUMBING DETAILS • • • C-4 SITE LAYOUT PLAN • • P601 PLUMBING SCHEDULES • • C-5 PAVING & GRADING PLAN • • P901 PLUMBING RISER DIAGRAM • • • C-6 UTILITY PLAN • • • P902 PLUMBING RISER DIAGRAM • • C-7 CONSTRUCTION DETAILS • • P903 PLUMBING RISER DIAGRAM • C-8 CONSTRUCTION DETAILS 0 • ELECTRICAL SURVEY E000 ELECTRICAL LEGENDS AND NOTES • • • 1 I ALTA SURVEY 1 OF 2 • E001 ELECTRICAL RISER DIAGRAM • • 2 1 ALTA SURVEY 2 OF 2 1*1 E002 ELECTRICAL FIRE ALARM LEGEND AND RISER • LANDSCAPE E101 LEVEL 1 POWER ELECTRICAL PLAN + + LP -1.01 PLANTING PLAN • • E102 LEVEL 1 LIGHTING ELECTRICAL PLAN • • LP -5.01 PLANTING DETAILS • • E102,1 LEVEL 1 LIGHTING ELECTRICAL SITE PLAN • • LP -6.01 PLANTING NOTES & SCHEDULE • • E103 ROOF ELECTRICAL PLAN 9101 • IRRIGATION E201 LEVEL 1 - FIRE ALARM ELECTRICAL PLAN + 1 W Q LIi-1.01 IRRIGATION PLAN EXIST EXISTING OS OVERFLOW SCUPPER E501 ELECTRICAL DETAILS FD FLOOR DRAIN PF PRE -FABRICATED w > W _I 0 Q �/ W z 0(� z O t- c 0 `r"" r~. N Q 0 w 0 O LL 0 z Q w FE FIRE EXTINGUISHER PLWD FIRE -RETARDANT TREATED PLYWOOD LOCATION MAP i DRAWINGS DRAWINGS ISSUED DRAWINGS DRAWINGS ISSUED 3 4 5 e- N N > > Lh q Ln > > co d Ln > > U) GWL' 2' W U) wLL' w w' O O O w w O O O CD C/) �>>> > > > c, �C)w H0wI L)Ix Ix W H H tY lY LY W h w CO I Ix 1-- Z Z I_- Z Z Z w w 'S 'S w w wan.00o Wa.aoo0 ar- ti I- rte- 00 w .- 0- I r :° o o O a O h N N N N N r N CV N CV CV r P N N N 14 N N CCS e3 00 'SHEET# o cSHEET # SHEET NAME 0 a o SHEET NAME GENERAL PLUMBING 100 S. Ashley Dr., P: 813 - 323 - 9233 G-000 ICOVERSHEET 10101 P000 PLUMBING LEGENDS AND NOTES • Ste. 100 Lic. #: AA- 0003590 G-010 LIFE SAFETY PLAN 101*1 P101 LEVEL1 UNDERGROUND PLUMBING PLAN • • • Tampa, FL 33602 W: www.bdglip.com CIVIL P102 LEVEL1 ABOVE GROUNDPLUMBING PLAN • • C-1 COVER SHEET • P103 ROOF PLUMBING PLAN • • C-2 GENERAL NOTES 0 • P401 PLUMBING ENLARGED PLANS • C-3 SOIL EROSION CONTROL PHASE I & DEMO PLAN . • P501 PLUMBING DETAILS • • • C-4 SITE LAYOUT PLAN • • P601 PLUMBING SCHEDULES • • C-5 PAVING & GRADING PLAN • • P901 PLUMBING RISER DIAGRAM • • • C-6 UTILITY PLAN • • • P902 PLUMBING RISER DIAGRAM • • C-7 CONSTRUCTION DETAILS • • P903 PLUMBING RISER DIAGRAM • C-8 CONSTRUCTION DETAILS 0 • ELECTRICAL SURVEY E000 ELECTRICAL LEGENDS AND NOTES • • • 1 I ALTA SURVEY 1 OF 2 • E001 ELECTRICAL RISER DIAGRAM • • 2 1 ALTA SURVEY 2 OF 2 1*1 E002 ELECTRICAL FIRE ALARM LEGEND AND RISER • LANDSCAPE E101 LEVEL 1 POWER ELECTRICAL PLAN + + LP -1.01 PLANTING PLAN • • E102 LEVEL 1 LIGHTING ELECTRICAL PLAN • • LP -5.01 PLANTING DETAILS • • E102,1 LEVEL 1 LIGHTING ELECTRICAL SITE PLAN • • LP -6.01 PLANTING NOTES & SCHEDULE • • E103 ROOF ELECTRICAL PLAN 9101 • IRRIGATION E201 LEVEL 1 - FIRE ALARM ELECTRICAL PLAN + 1 W Q A-510 ROOF DETAILS • • *1 FS -3.1 DIMENSIONED PLUMBING • LIi-1.01 IRRIGATION PLAN • FS -3.2 UNDERGROUND PLUMBING • • E501 ELECTRICAL DETAILS • A-620 PARTITION TYPES 1010 • FS -5.0 INTERIOR ELEVATIONS • U) D O r V J w > W _I 0 Q �/ W z 0(� z O t- c 0 `r"" r~. N Q 0 w 0 O LL 0 z Q w S1 GENERAL NOTES &INFORMATION • LI -5.01 IRRIGATION DETAILS • • E601 ELECTRICAL SCHEDULES • • LI -6.01 IRRIGATION NOTES AND SCHEDULE . • E602 ELECTRICAL KITCHEN EQUIPMEMENT SCHEDULE • + ARCHITECTURAL LC SYSTEMS A-100 FLOOR PLAN • • • • LC1 COOKLINE HOOD HOOD SCHEDULE • A-101 DUMPSTER PLANS • • • LC2 PREP HOOD • A-120 ROOF PLAN • • LC3 DISH HOOD FAN SCHEDULE • A-130 REFLECTED CEILING PLAN • . • LC4 DETAILS & ELECTRICAL CONNECTIONS • A-140 PLAN DETAILS • • • LC5 UL.DUCT • A-200 EXTERIOR ELEVATIONS • • • EQUPMENT A-201 EXTERIOR ELEVATIONS • • • EQ -1.0 EQUIPMENT PLAN • L • A-202 EXTERIOR ELEVATIONS • • EQ -2.0 EQUIPMENT SCHEDULE • L • A.-300BUILDING SECTIONS • • • . EQ 3.0 KITCHEN ITCHEN ELEVATIONS • A-301 BUILDING SECTIONS • . . EQ -3.1 KITCHEN ELEVATIONS A-302 BUILDING SECTIONS • • • EQ -3.2 KITCHEN ELEVATIONS • A-310 WALL SECTIONS • • EQ -3.3 KITCHEN ELEVATIONS • A-311 WALL SECTIONS • • EQ -3.4 KITCHEN ELEVATIONS • A-312 WALL SECTIONS • • • FIXTURE A-313 WALL SECTIONS • • • FS -1.0 KEY TO ELEVATIONS • • A-314 WALL SECTIONS • • • FS -2.0 ELECTRICAL ROUGH INS • • • A-400 ENLARGED RESTROOM PLANS AND ELEVATION • • • FS -2.1 CONDUIT LAYOUT • • A410 ENLARGED KITCHEN WALL • • • FS -2.2 POS WIRING DIAGRAM + • A-500 WALL DETAIL • + • FS -2.3 TELEPHONE LAYOUT • • A-501 ROOF DETAILS • • FS -3.0 PLUMBING ROUGH INS • A-510 ROOF DETAILS • • *1 FS -3.1 DIMENSIONED PLUMBING • 41 Architect of Record Gregg A. Holdsworth, AIA, LEED AP FL License # AR0017669 ISSUE BY DATE DESCRIPTION 1 RC 08-24-2017 PERMIT COMMENTS 2 RC 9-28-2017 PERMIT COMMENTS 2 3 RC 10-16-2017 OWNER REVISIONS 4 GH 11-21-2017 OWNER REVISIONS 5 SS 01-04.2018 OWNER REVISIONS PROJECT INFORMATION BLOCK JOB # 170018 DATE: 07.6-2017 DRAWN BY: RC CHEOKED BY: SS SHEET TITLE COVERSHEET SHEET NUMBER A-600 DOOR SCHEDULE AND DETAILS • • FS -3.2 UNDERGROUND PLUMBING • a A-610 WINDOW AND ROOM FINISH SCHEDULE 1010 • FS -4.0 FINISHES • • A-620 PARTITION TYPES 1010 • FS -5.0 INTERIOR ELEVATIONS • THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER "PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG .ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR HAKO BEFBDG THESE PLANS FORECONSTRUCTIO WRITTEN PERMISSION ARCHITEACTTS.0 E OFWITHOUT CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABIUTY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS APPROVAL OF BDG ARCHITECTS; OR ANY WITHOUT THE EXPRESS WRITTEN AP RO OU H CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABIUTY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR RELATEDTEFERREO THE ANS.AN IMMEDIATELY DGESORCONFUCT5INTHEPLANs .SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR TO PRIOR TO INUING WITH THE WORK. DI CRREPANCIESORCONFLICTSTOBDGARCHTECTSSPRIORTO FAILURE TOREFER PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDUUNG AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. STRUCTURAL FS -5.1 IN'T'ERIOR ELEVATIONS • • S1 GENERAL NOTES &INFORMATION • FS -5.2 I NTERI(iR EL VA TIONS • • 51.1 WIND LOAD DATA • FS -5.3 INTERIOR EL NATIONS • • S2 FOUNDATION PLAN • • • • FS -6.0 BAR DETAIL:? • S3 ROOF FRAMING PLAN • FS -6.1 BAR DETAILS • S4 FOUNDATION DETAILS • • • • FS -7.0 BEER SYSTEM' • S5 ROOF FRAMING DETAILS • FS -7.1 SODA SYSTEM • 56 FRAMING ELEVATIONS • FS -8.0 WALL CONSTR. • S7 FRAMING SECTIONS AND DETAILS • FS -9.0 MILLWORK DETAILS • S8 FRAMING SECTIONS AND DETAILS • FS -9.1 MILLWORK DETAILS • S9 DUMPSTER ENCLOSURE PLAN • • FS -10.0 DECOR PLAN • S10 SATELLITE & DUMPSTER ENCLOSURE DETAILS + FIRE MECHANICAL F000 FIRE PROTECTION LEGENDS AND NOTES • M000 HVAC LEGENDS AND NOTES • F001 ARE PROTECTION SITE PLAN • M101 LEVEL 1 HVAC PLAN • • F101 LEVEL 1 FIRE PROTECTION PLAN • M103 ROOF HVAC PLAN • F501 FIRE PROTECTION DETAILS • SEAL M401 HVAC DUCTWORK SECTIONS • SIGNAGE M501 HVAC DETAILS • N-1 SIGN DRAWINGS • M601 HVAC SCHEDULES • N-2 SIGN DRAWINGS • N-3 SIGN DRAWINGS • N-4 SIGN DRAWINGS • 41 Architect of Record Gregg A. Holdsworth, AIA, LEED AP FL License # AR0017669 ISSUE BY DATE DESCRIPTION 1 RC 08-24-2017 PERMIT COMMENTS 2 RC 9-28-2017 PERMIT COMMENTS 2 3 RC 10-16-2017 OWNER REVISIONS 4 GH 11-21-2017 OWNER REVISIONS 5 SS 01-04.2018 OWNER REVISIONS PROJECT INFORMATION BLOCK JOB # 170018 DATE: 07.6-2017 DRAWN BY: RC CHEOKED BY: SS SHEET TITLE COVERSHEET SHEET NUMBER OUTDOOR TRANSFER SWITCH, SWITCHBOARDS AND PANEL'C' PROVIDED BY W.R. CONTROLS AT 1-800-417-7543 69,532 AFC UTILITY PAD MTD TRANSFORMER 120/208V.30 NOTE: COMPLY WITH LOCAL UTILITY CO. METER & C.T. ARRANGEMENT PRIOR TO INSTALLATION. FURNISH AND INSTALL AS REQUIRED BY LOCAL UTILITY COMPANY. 0 METER FURNISHED AND INSTALLED BY E.C. 2 A O ATS O 4 NEW SWITCHBOARD 'MDP' 120/208V/30/4W 1000A MLO / * D PANEL "B" 225A MLO 120/208V.30 NEMA -1 D 44830 AFC 65K AIC BYPASS * 120/208V.30 NEMA -1 D 39844 AFC PANEL "E" 65K AIC 5 KVA 49,995 AFC D 225A MLO UPS o- 120/208V.30 PANEL "POS" ' PANEL "A" B PANEL "S" 225A MLO 225A MLO 120/208V.30 120/208V.30 NEMA -1 m (NEMA -1 44830 AFC Q 44830 AFC 65K AIC * 65K AIC zu- HIG"PDM fy. 100A MLO 0 G * HIGHEST BREAKER IN SWITCHGEAR SHALL NOT BE GREATER THAN A HEIGHT OF 6-6"AFF. r of 6'-0„ v MI IN, I GROUNDING ELECTRODE SYSTEM CONSISTING OF (2) 5/8" X 10' COPPER CLAD GROUND RODS, BOND TO BUILDING STEEL, BOND TO CONCRETE ENCASED ELECTRODE ( ELECTRODE SHALL BE AT LEAST 1/2" AND ENCASED WITHIN AT LEAST 2" OF CONCRETE) AND COLD WATER PIPE. ICI E FURNISHED AND INSTALLED BY E.C. PANEL "C" 225A MLO 120/208V.30 NEMA -1 33460 AFC 65K AIC PANEL "D" 100A MLO 120/208V.30 NEMA -3R MARLIN DIMMING 1 OK AIC Riser Diagram 120/208V. 30 YED D WING OTES 1. 100% RATED, 65KAIC 1000/3P/NEMA 3R SERVICE RATED TRANSFER SWITCH WITH 1000A BREAKER PROTECTION, ON NORMAL AND EMERGENCY SIDE. (FURNISHED BY OWNER AND INSTALLED BY E.C.). TRANSFER SWITCH SHALL BE 3 -POLES. GENERATOR CONNECTED SHALL NOT BE CONFIGURED AS SEPARATELY DERIVED SOURCE 2. CT METER CABINET AND 1" CONDUIT BY E.C. METER, CTs AND CONNECTIONS BY UTILITY COMPANY. VCIVGrVAL NW 1 G;0 1. TEXAS ROADHOUSE TO SUPPLY THE FOLLOWING ELECTRICAL DISTRIBUTION EQUIPMENT. EC TO SUPPLY ALL LABOR TO UNLOAD AND INSTALL DISTRIBUTION EQUIPMENT: A) SWITCHBOARD MDP WITH FACTORY INSTALLED PANELBOARDS MDP, A, B, E, S, POS & IG. B) PANELBOARDS C AND D WILL BE SUPPLIED AS LOOSE COMPONENTS: BACK BOX, INTERIOR & TRIM, C) FACTORY INSTALLED TIME CLOCK. CONNECT TO E-26. D) MAIN EXTERIOR 1000 AMP DISCONNECT SWITCH. E) FACTORY INSTALLED TVSS. CONNECT TO IG- 14/16/18 2. EC TO CHECK AD TIGHTEN ALL ELECTRICAL CONNECTIONS BEFORE ENERGIZING. 3. ALL CABLING BETWEEN THE MDP MAIN BREAKERS AND THE INDIVDUALL PANELBOARDS IN PANEL WALL IS FACTORY SUPPLIED. EC IS RESPONSIBLE FOR THE FIELD TERMINATION OF EACH CABLE. 4. ALL WIRING BETWEEN PANELBOARD E, PANELBOARD IG, THE FACTORY SUPPLIED TIME CLOCKS AND THE FACTORY SUPPLIED LIGHTING CONTROL SYSTEMIS FACTORY INSTALLED. 5. EC TO SUPPLY AND INSTALL ALL MATERIALS REQUIRED TO ACTIVATE THE FACTORY INSTALLED 120 VAC SHUNT TRIP DEVICE IN MDP BREAKER THAT FEEDS PANEL S. 6. SWITCHBOARD WILL SHIP IN(1) VERTICAL SECTION AS SHOWN ON SHEET E5. 7. ALL CONDUITS SHALL BE 3/" UNLESS NOTED OTHERWISE. * 120/208V.30 NEMA -1 D 39844 AFC PANEL "E" 65K AIC 5 KVA 49,995 AFC D 225A MLO UPS o- 120/208V.30 PANEL "POS" ' B Q W� NEMA -1 30A MCB 0 65K AIC 44830 AFC 1 10 BATT 20 V- 65K AIC EMA- m Q 65K AIC Q W w0 cl� G * HIGHEST BREAKER IN SWITCHGEAR SHALL NOT BE GREATER THAN A HEIGHT OF 6-6"AFF. r of 6'-0„ v MI IN, I GROUNDING ELECTRODE SYSTEM CONSISTING OF (2) 5/8" X 10' COPPER CLAD GROUND RODS, BOND TO BUILDING STEEL, BOND TO CONCRETE ENCASED ELECTRODE ( ELECTRODE SHALL BE AT LEAST 1/2" AND ENCASED WITHIN AT LEAST 2" OF CONCRETE) AND COLD WATER PIPE. ICI E FURNISHED AND INSTALLED BY E.C. PANEL "C" 225A MLO 120/208V.30 NEMA -1 33460 AFC 65K AIC PANEL "D" 100A MLO 120/208V.30 NEMA -3R MARLIN DIMMING 1 OK AIC Riser Diagram 120/208V. 30 YED D WING OTES 1. 100% RATED, 65KAIC 1000/3P/NEMA 3R SERVICE RATED TRANSFER SWITCH WITH 1000A BREAKER PROTECTION, ON NORMAL AND EMERGENCY SIDE. (FURNISHED BY OWNER AND INSTALLED BY E.C.). TRANSFER SWITCH SHALL BE 3 -POLES. GENERATOR CONNECTED SHALL NOT BE CONFIGURED AS SEPARATELY DERIVED SOURCE 2. CT METER CABINET AND 1" CONDUIT BY E.C. METER, CTs AND CONNECTIONS BY UTILITY COMPANY. VCIVGrVAL NW 1 G;0 1. TEXAS ROADHOUSE TO SUPPLY THE FOLLOWING ELECTRICAL DISTRIBUTION EQUIPMENT. EC TO SUPPLY ALL LABOR TO UNLOAD AND INSTALL DISTRIBUTION EQUIPMENT: A) SWITCHBOARD MDP WITH FACTORY INSTALLED PANELBOARDS MDP, A, B, E, S, POS & IG. B) PANELBOARDS C AND D WILL BE SUPPLIED AS LOOSE COMPONENTS: BACK BOX, INTERIOR & TRIM, C) FACTORY INSTALLED TIME CLOCK. CONNECT TO E-26. D) MAIN EXTERIOR 1000 AMP DISCONNECT SWITCH. E) FACTORY INSTALLED TVSS. CONNECT TO IG- 14/16/18 2. EC TO CHECK AD TIGHTEN ALL ELECTRICAL CONNECTIONS BEFORE ENERGIZING. 3. ALL CABLING BETWEEN THE MDP MAIN BREAKERS AND THE INDIVDUALL PANELBOARDS IN PANEL WALL IS FACTORY SUPPLIED. EC IS RESPONSIBLE FOR THE FIELD TERMINATION OF EACH CABLE. 4. ALL WIRING BETWEEN PANELBOARD E, PANELBOARD IG, THE FACTORY SUPPLIED TIME CLOCKS AND THE FACTORY SUPPLIED LIGHTING CONTROL SYSTEMIS FACTORY INSTALLED. 5. EC TO SUPPLY AND INSTALL ALL MATERIALS REQUIRED TO ACTIVATE THE FACTORY INSTALLED 120 VAC SHUNT TRIP DEVICE IN MDP BREAKER THAT FEEDS PANEL S. 6. SWITCHBOARD WILL SHIP IN(1) VERTICAL SECTION AS SHOWN ON SHEET E5. 7. ALL CONDUITS SHALL BE 3/" UNLESS NOTED OTHERWISE. THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER "PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF: BDG ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF'BDG ARCHITECTS, USE OF THESE PLANS FOR CONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS, ANY DISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. Adam T. Powell, PE PE0073853 r®,,11 Y IT. POjV I , 1 STAT ®F p 0 40 O #7 ELECTRICAL SEAL 1/4/201810:33:12 AM ISSUE BY DATE DESCRIPTION 3 10-16-2017 OWNER COMMENTS 5 01-04-2018 Revision 5 PROJECT INFORMATION BLOCK JOB # 170509 DATE: 7-6-2017 DRAWN BY: Author CHECKED BY: Checker SHEET TITLE ELECTRICAL RISER DIAGRAM SHEET NUMBER E001 o �W VJ Q W� 0 �M Z m Q Q W w0 cl� 0 zu- fy. W U� 0 U) Z o ILL OZ u) W o THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER "PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF: BDG ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF'BDG ARCHITECTS, USE OF THESE PLANS FOR CONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS, ANY DISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. Adam T. Powell, PE PE0073853 r®,,11 Y IT. POjV I , 1 STAT ®F p 0 40 O #7 ELECTRICAL SEAL 1/4/201810:33:12 AM ISSUE BY DATE DESCRIPTION 3 10-16-2017 OWNER COMMENTS 5 01-04-2018 Revision 5 PROJECT INFORMATION BLOCK JOB # 170509 DATE: 7-6-2017 DRAWN BY: Author CHECKED BY: Checker SHEET TITLE ELECTRICAL RISER DIAGRAM SHEET NUMBER E001 20 0. LEVEL 1 POWER ELECTRICAL PLAN 1/411 = 1'-0" O ...................... OUTDOOR WAITING AREA 001 C - 52,54 2.9 2.7 2.3 _O Power - Sheet Notes Key Value Keynote Text 1 NEON OUTLET SURFACE MOUNTED ABOVE 2x8 LEDGER ORAS NOTED. REFER TO DRAWINGS E101 PRIOR TO ROUGH -IN. 2 J -BOX WITH MUD RING AND FACE PLATE FOR P.O.S COMMUNICATION CABLE, J -BOX AT OUTLET HEIGHT. PROVIDE CONDUIT FROM J -BOX LOCATION INDICATED ON E101 RUNS WILL BE UNDERGROUND AND OVERHEAD. PROVIDE PULL STRINGS IN ALL CONDUITS. 3 CIRCUIT SHALL RUN DEDICATED BACK TOCIRCUIT BREAKER AT PANEL, FOR CIRCUITS WITH MULTIPLE OUTLETS THE CIRCUIT SHALL BE CONNECTED AT THE CIRCUIT BREAKER. EACH CIRCUIT SHALLHAVE A HOT, NEUTRAL, ISOLATED GROUND AND GROUND WIRE. AL P.O.S AND TABLE CHECK COMMINICATIONS CABLES TO BE FURNISHED AND INSTALLED BY OWNER. (2#12,1#12G.,1#121G.,3/4"C.) RECEPTACLES LOCATED IN KITCHEN SHALL BE CIRCUITED TO GFCI CIRCUIT BREAKERS OR SHALL BE WEATHER -RESISTANT IG-GFCI TYPE RECEPTACLES, 4 WORLD DRYER VERDIDRI MODEL #Q -162A BTM.OF AIR DISPENSER HAND DRYER, 110-120V/l w, 996W. 5 MOUNT HORIZONTALLY IN BAR DIE AS HIGH AS POSSIBLE. 6 RECEPTACLE & CABLE T.V. OUTLET FURNISHED AND INSTALLED BY E.C. CABLE INSTALLED BY OWNER. VERIFY EXACT LOCATION WITH OWNER PRIOR TO ROUGH -IN. 7 120V CIRCUIT FOR NEON SIGN, COORDINATE EXACT LOCATIONS WITH OWNER PRIOR TO ROUGH -IN. 8 BERKO #FFCH5581FFCH RE/FFCH-TK FAN FORCED RECESSED MOUNTED HEATER, 208V/1 w, 5000W. PROVIDE WALL THERMOSTAT SET AT 60F. 9 _ QUAD RECEPTACLE FOR PAGER DEVICE AT HOSTESS STAND. 10 1/2" CONDUIT BACK TO TELEPHONE BACKBOARD WITH CABLE (24 GA., 64 4W) FURNISHED AND INSTALLED BY CONTRACTOR, THE PHONE JACK SHALL BE INSTALLED IN A 4" BOX, WITH A SINGLE -GANG MUD RING. 11 J -BOX FOR STUB UP INTO WALL AND FEED THROUGH PLATFORM. 12 J -BOX FOR SPEAKER WIRE AT LOCATION SHOWN. 13 _ CCN MONITOR IN TO GO AREA. 14 2#12,1#12G.,1 1#121G., 3/4"C. 15 MOUNT TWO RECEPTACLES, ONE AT 18" AND ONE AT 30" AFF, FOR STACKED CONVECTION OVENS. 16 PROVIDE JUNCTION BOX MOUNTED AT 96" ABOVE FINISHED FLOOR INSIDE OF BULKHEAD FOR HANGING HEAT LAMPS. 120V,1 o, 250W EACH. 17 Q-MARK#FRP236AS FAN FORCED CEILING MOUNTED NEATER, 208V/1o, 3000W. WIRE HEATER THROUGH CP2004801 FOUR 3 -POLE CONTACTOR PANEL, THEN TO (1) TOGGLE SWITCH TO CONTROL (3) HEATERS. KICATE TOGGLE SWITCH IN EXPO AREA NEAR FAN SWITCHES; COORDINATE WITH TEXAS ROADHOUSE REPRESENTATIVE. 18 J -BOX AT 60" A.F.F. WITH 112" CONDUIT TO 6" ABOVE CEILING FOR MICROPHONE. 19 J -BOX FOR CCTV AT 8'-6" A.F.F, STUB CONDUIT ABOVE CEILING. 20 1/2"x 2'x4' PLYWOOD BACKBOARD FOR TELEPHONE EQUIP. (1) DEDICATED OUTLET FOR TELEPHONE EQUIPMENT AND (2) QUAD OUTLETS FOR SECURITY SYSTEM VENDOR. 21 RECEPTACLE FOR FACP. COORDINATE WITH FA1 SHEET FOR EXACT LOCATION. 22 PROVIDE JUNCTION BOX FOR TELEPHONE CONNECTION. 23 J -BOX FOR DOOR ALARM SYSTEM WITH 1/2" CONCEALED CONDUIT AT 5'-6" A.F.F TO ABOVE DOOR MAGNETIC HOLDER. 24 J -BOX FOR FLY FAN WITH CONNECTION TO DOOR SWITCH, MOUNT 86" A.F.F. 25 PROVIDE POWER CONNECTION TO PREFABRICATED WATERHEATER RACK LOAD CENTER, AS REQUIRED BY MANUFACTURER. 26 FAN MOTOR CONTROL CENTER ABOVE ELECTRICAL PANEL, HOLD TIGHT TO CEILING. SEE HOOD DRAWINGS FOR WIRING DIAGRAMS. 27 OUTLET FOR GLYCOL CHILLER, VERIFY LOCATION WITH OWNER PRIOR TO MOUNTING. 28 FOR UNDERCOUNTER BAR LIGHTING SWITCHED. MOUNT SWITCH UNDER BOX NEXT TO OUTLET. 29 PROVIDE JUNCTION BOX FOR CONNECTION OF DIMMER REMOTE CONTROL PANEL MOUNTED 60" ABOVE FINISHED FLOOR. 30 ROUTE NEON SIGN OUTLETS THROUGH WALL SWITCH LOCATED ADJACENT TO FAN SWITCH. 31 COORDINATE WITH DOOR ALARM MANUFACTURER'S CUTSHEET FOR WIRING ALARM TO TRANSFORMER TO PANEL CIRCUIT BREAKER. 32 INSTALL SO PANEL TRIM IS FLUSH WITH SIDING AT THIS AREA. _ 33 EXTERIOR SIGN SEE ARCHITECTURAL BLDG. ELEVATIONS. GROUNDING SHALL BE ISOLATED AND DEDICATED BACK TO ELECTRICAL PANEL, COORDINATE WITH SIGN INSTALLER. _ 34 INSTALL IRRIGATION TIMECLOCK IN REAR WALL OF UNILITY ROOM. COORDINATE WITH LANDSCAPE DRAWINGS. 35 J -BOX ABOVE HOOD FOR OIL RECOVERY ALARM. 36 DOOR BELU DOOR BUZZER AND TRANSFORMER. PROVIDED BY ELECTRICAL CONTRACTOR, 37 PROVIDE CLEARANCES FOR ELECTRICAL PANELS PER N.E.C. 110.26. PANEL CIRCUIT BREAKER SHALL BE AN ACCESSIBLE HEIGHT OF 6'-7" AFF PER NEC 404.8. 38 RECEPTACLE FOR NEON SIGN MOUNTED ON TOP OF TIN ROOF. 39 RECEPTACLE FOR NEON SIGN MOUNTED ON TOP OF HEADER. (78' AFF) 40 CONNECTION FOR EVAPORATOR COIL INSIDE WALK-IN. EXTEND INTERWIRING TO ROOF COMPRESSOR PER MANUFACTURER'S DRAWINGS. 41 PROVIDE CONNECTION FOR HEAT TAPE AT CONDENSATE LINE. COORDINATE LOCATION WITH G.C. 42 PROVIDE CIRCUIT FOR CONDENSATE DRAIN LINE HEATER AS REQUIRED. 43 120V 1 o CONNECTIONS FOR LIGHTS, DOOR HEATERS AND DEFROST TIMERS ALL WALK-IN LIGHTS AND DOOR HEATER CONNECTIONS AND INSTALLATIONS ARE THE RESPONSIBLITY OF THE ELECTRICAL CONTRACTOR. LIGHTING CONDUIT TO BE RUN ABOVE WALK-IN BOX AND ALL PENETRATIONS THROUGHLY SEALED. LIGHT FIXTURES FURNISHED UNINSTALLED BY THE WALK-IN SUPPLIER, INSTALLATION AND WIRING BY THE ELECTRICAL CONTRACTOR. SEE SHEET EQ4 FOR LOCATION OF DEFROST TIMERS. 44 E.C. SHALL CONNECT "FLOW AND TAMPER" SWITCHES ON BOTH O.S. & Y VALVES OF THE BACK FLOW PREVENTION DEVICE ON THE FIRE SPRINKER RISER, SWITCHES SHALL CONNECT TO THE BUILDING SECURITY SYSTEM. E.C. SHALL COORDINATE WITH FIRE SPRINKLER AND SECURITY SYSTEM VENDOR PRIOR TO INSTALLATION. 45 J -BOX FOR MICROPHONE. 46 J -BOX FOR CATS & TEL JACK IN MILLWORK. 47 (2) 2" C FOR TELEPHONE AND CABLE TV. NOTE: ALL CONDUIT TO BE RUN OUTSIDE OF WALK-IN AND PENETRATIONS TO BE THOROUGHLY CAULKED WITH FOOD GRADE SILICONE SEALER. RACEWAYS THAT PENETRATE COOLERS THAT ARE KNOWN TO BE SUBJECT TO DIFFERENT TEMPERATURES AND CONDENSATION SHALL BE FILLED INSIDE THE RACEWAY WHERE IT ENTERS THE COOLER WITH AN APPROVED MATERIAL TO PREVENT THE CIRCULATION OF WARM AIR TO THE COOLER SECTION. (SEE 300.7 OF NFPA 70). GENERAL NOTES 1. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT SHOWN ON THIS DRAWING. 2. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATION AND REQUIREMENTS OF ALL PLUMBING EQUIPMENT SHOWN ON THIS DRAWING. EC, TO FURNISH & INSTALL CONDUIT(S) & J -BOXES) FOR T -STAT OF EACH RTU, SEE SHEET M103 FOR LOCATION & COORDINATE W/ M.C. NOTE: E.C. TO CONSULT HOOD MANUFACTURER'S WIRING DIAGRAMS AND CONTROL CABINET LAYOUT FOR ALL EXHAUST HOOD FAN REQUIREMENTS, FOR DRAWINGS CONTACT OWNER OR LC SYSTEMS @ 1-614-235-9430. GENERAL SHEET NOTES 1. REFER TO PANEL SCHEDULES ON E601 FOR ALL CONDUCTOR SIZES 3. PROVIDE NO. 10 WIRE IN LIEU OF N0, 12 WIRE FOR ANY BRANCH CIRCUIT EXCESS OF 100 FEET (120V) OF CIRCUIT LENGTH TO FARTHEST DEVICE TO PREVENT EXCESSIVE VOLTAGE DROP, PROVIDE NO.8 WIRE IN LIEU OF NO. 10 WIRE FOR ANY BRANCH CIRCUIT IN EXCESS OF 160 FEET (120V) OF CIRCUIT LENGTH TO FARTHEST DEVICE TO PREVENT EXCESSIVE VOLTAGE DROP. i 205 N: ARMENIA AVE; #102 TAMPA; FL 33609 TEL, (813) 995-0300 FAX (813)995-0400 FLORIDA ENGINEERING BUSINESS #002784 COPYRIGHT 2016- EMERALD ENGINEERING W 0 W o D M = O< Q coo Q zLijU_ OC co r� //'�� VJ LIJ z W 0 �z O U) W 0 C_ THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS )HEREINAFTER "PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS: OR ANY CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS. ANY DISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. Adam T. Powell, PE PE007385 ®®\®11111111/ T. P01V 61-4-zol'� .: 1 � v \\ TE 0 NAI. 1111?`® ELECTRICAL SEAL 1/4/201810:33:13 AM ISSUE BY DATE DESCRIPTION 3 10-16-2017 OWNER COMMENTS 5 01-04-2018 Revision 5 PROJECT INFORMATION BLOCK JOB # 170509 DATE: 7-6.2017 DRAWN BY: Author CHECKED BY: Checker SHEET TITLE LEVEL1 - POWER ELECTRICAL PLAN SHEET NUMBER E1 01 C C PANELBOARD: D LOCATION: VOLTAGE: 208Y/120 V. 3 o 4 W. MOUNTING: RECESSED... A.I.C. RATING: 10,000 AMPS SYMMETRICAL MAIN DEVICE: 100 A MLO SPECIAL: BUS AMPS: 100 AMPS LOAD DESCRIPTION BKR P NOTES CKT PANELBOARD: A NOTES P BKR LOAD DESCRIPTION TRACK LIGHTS @ BAR... 20 A 1 2 A 1 1 PANELBOARD: B -,; r_ r w 2 1 -- -- - 20 A LOCATION: TRACK LIGHTS @ ENTRY 20 A 1 1 VOLTAGE: 208Y/120 V. 3 o 4 W. 0.1 0.0 " „;" : 4 5 7 LOCATION: 20 A DINING LIGHTS (PENDANT)_ TRACK LIGHTS @ BAR... 20 A 1 VOLTAGE: 208Y/120 V. 3 o 4 W. 5 0.0 0.0 0.1 0.1 6 MOUNTING: SURFACE... 1 20 A DINING LIGHTS (PENDANT) A.I.C. RATING: 65,000 AMPS SYMMETRICAL 20 A 1 SPARE 7 MOUNTING: SURFACE... � 0.0 8 10 _13 15 A.I.C. RATING: 65,000 AMPS SYMMETRICAL 20 A 20 A TRACK LIGHTS @ ENTRY ENTRY LIGHTS TRACK LIGHTS 20A 1 9 0.1 MAIN DEVICE: 225 A MLO 20 A 1 SPECIAL: 11 20 A 0 1 0 0 12 KITCHEN LIGHTS SITE LIGHTING_ - MAIN DEVICE: 225 A MLO TRACK LIGHTS @ WAITING DINING LIGHTS 20 A 1 SPECIAL: 13 0.1 0.1 ,.;. 20 A 14 20A 1 1 BUS AMPS: 225 AMPS DINING LIGHTS BAR LIGHTS 20 A 1 -20 A 150.1 20 A 0.1 16 BUS AMPS: 225 AMPS 20 A _ TRACK LIGHTS @DINING DINING LIGHTS 20 A 1 NEON OUTLET 17 SPARE 0.1 0.1 18 25 -1 1 20 A TRACK LIGHTS @ DINING EMERGENCY/EXIT... 20 A 1 L 1,2 19 0.5 0.0 _: ', •' M„ung 20 P R 0 0 1.5 , 1 1 20 A I DO NOT USE DINING / WAITING FANS 21 A 10 A NEON OUTLETS _ TOTAL LOAD: TOTAL AMPS: 1 kVA 0 kVA 0 kVA 8A 3A 4A 29 .. 0.1 0.5. LOAD DESCRIPTION BKR P NOTES CKT PHASE PHASE B kPHASE VA A kVA C kVA CKT NOTES P BKR LOAD DESCRIPTION LOAD DESCRIPTION BKR P _ NOTES CKT PHASE PHASE B A kVA kPHASEVA C kVA CKT NOTES P BKR LOAD DESCRIPTION 20 A NEON OUTLET WALK-IN MEAT COOLER O ROOF COMPRESSOR ( N )`'' 20 A 3 22 1 1.6 0 9KF .. 2 ; „ , .,, „ 3 1.6 0 9 4 1794 VA_ 2 20A WALK IN FREEZER COIL GP OUTLETS AT BAR 20 A 1 1 1 0.7 0,9 „' 2 2 1 20 A BAR UC REFRIGIRATOR SPARE 20 A 1 3 0 0 0.5 4 1_ 20A SECURITY SYSTEM 5'; 1.6 1.8 6 7 1.6 1.8 ., 8 9 1 6 1 8 10 1 3 30 A ICE MACHINE REMOTE CONDENSER (ON ROOF) SODA DISPENSER 20 A 1 2 5 1.5 0 8 6 ICE TEA BREWER 20 A l 2 70 6 0.5 8 TELEPHONE BACKBOARD 20 A 1 9 0.2 0.4 10 1 20 A SECURITY SYSTEM - WALK-IN COOLER COMPRESSOR (ON ROOF) 20 A 3 20 A 1 20 A OFFICE RECEPTACLE 1_ 20A _ OFFICE OUTLETS 11440 1.6 1.2 12 1 1 20 A WALK-IN LIGHTS AND DOO... MUSIC SYSTEM 20 A 1 11 _ ,,. �' 1 0 1.5 12 1 20 A LIQUOR DISPLAY MEAT COOLER... 20 A 1 12800 VA 1 13 0.5 0.4 tea: •,,,; ,. , 14 LOAD: 28518 VA -- 1 20 A UC REF. _� GLASS WASHER 20 A 1 13 0.9 0.8 14 2 1 20 A BOTTLE COOLER _ TV OUTLETS 20 A 1 _CONNECTED ESTIMATED DEMAND: 30105 VA 15 1.1 1.8 „';, 16 1 20A EF -7 / 8 ON ROOF FROZEN COCKTAIL MACH... 20 A 1 2 15 °< ;• 1.8 0.7 16 2 1 20 A MUG FROSTIER _ 6492 VA 1.7 1.8 PAGER DEVICE 20 A 1 KTCH 17.;; 1.1 0.2 18 2 1 20 A CONVENIENCE HAND DRYER -... BAR UC REFRIGIRATOR 20A 20A 1 1 2 17 19 s; ,• 1.0 0.5 0.9 1.8 18 - - 20 1 20 A WALK-IN COOLER COIL SPARE 20A 1 37 19 0.0 0.4 "-, ',: 1 20 38 1 20 A CONVENIENCE OUTLET -- -- - 2 25 A CHEESE MELTER GRINDER @MEAT COOLER20 A 1 2 21 „ ..,._."' ";, 1.5 1.5 22 2 1 20 A CARBONATOR 0.5 .., HANGING HEAT LAMPS 20A 1 21tttt1 - 1.8 = „', 22 WORK TABLE... 20A 1 30 A 23 - .....,..: 0.5 0.0 24 25 0.2 U.6 gun • ,,,,,,, , „ " ", '" 26 3 1 20 A SPARE-�- EXTERIOR OUTLETS 20 A 1 23 ,,,w,•,-•,, 0.5 0.5 24 1 20 A OFFICE OUTLETS CD PLAYER RECEPTACLE 20 A 1 20 A 1 1 20 A ICE TEA BREWER CONVENIENCE OUTLETS 20A 1 25 2.0 0.2 SPARE 26 2 1 20 A GP OUTLETS @DISH... 0.0 1.5 , � �' 27 1 5 1 5 28 2 MUG FROSTER 20 A 1 2 27 0.7 1.5 r.. 28 WALK-IN FREEZER COMPRESSOR (ON ROOF) 20 A 3 2 20A 1 20 A UNDER BAR LIGHT - 2 1 20 A COFEE MAKER 29 1.5 1.5 30 50 1 20 A HEAT TAPE CONVENIENCE OUTLETS 2 A 1 29 n, q 0 9 1.1 30 1 20 A TV OUTLETS 31 1.5 1.8 , r. •, 32 1 3 -__ 30 A ICE MACHINE REMOTE CONDENSER (ON ROOF) _ _ HAND DRYER -... 20 A 1 31 1.0 0.0r 32 HAND DRYER -... 20 A 1 33 1.0 1.1 „'' ,• ':" 34 1 20 A SPARE BEER COOLER COIL - BEER GLYCOL 20A 20 A 1 1 2 33 0.5 1.8 .,: 34 35 W a ._r ..... `<.... 1.5 1.8 36 - 1 20 A --- TV OUTLETS - FREEZER/COOLER COMBO 20A 1 2 35 , '', `. 1.2 1.2 36 3 20 A MIXER BEER COOLER COMPRESSOR (ON ROOF) 20A 3 20 A 37 39 0.9 0.4 , • �, 0.9 0.9 38 40 2 1 1 1 20 A 1 20 A CONVENIENCE OUTLET ICE MACHINE SODA DISPENSER 20 A 1 2 37 1.! 1 2', ,, , ' ""• 38 CHILLED BEVERAGE... 20 A 1 2 39 0.4 1.2 40 41 -, 0.9 0.9 42 2 1 20 A ICE MACHINE CABLE TV OUTLETS 20 A 1 41 s•, 1.0 0.1 42 1 _ 20 A IRRIGATION TIME CLOCK LOAD CLASSIFICATION TOTAL LOAD: 12 kVA 18 kVA 16 kVA DEMAND ESTIMATED PANEL TOTALS Lighting TOTAL LOAD: 13 kVA 12 kVA_ 13 kVA 125.00% 1925 VA Other TOTAL AMPS: 102 A 158 A 136 A 100.00% 34486 VA _ _ CONNECTED LOAD: 61094 VA _ RCPT TOTAL AMPS: 110A 97 A _ 107 A ESTIMATED DEMAND: 56197 VA SPEC 1704 VA LOAD CLASSIFICATION CONNECTED DEMAND ESTIMATED PANEL TOTALS LOAD CLASSIFICATION CONNECTED CURRENT: 170 A CONNECTED DEMAND_ 14991 VA _ ESTIMATED 65.00% 9744 VA PANEL TOTALS --� O Other 32919 VA 100.00% 32919 VA _ 1. GF61 BREAKE Other 5 7610 VA 100.00% 7610 VA 2.(2) #10 CU, (1) #10 CU EG. - _ _ _ RCPT 11801 VA 92.37% 10901 VA 3. (3) #10 CU , (1) #10 CU EG. CONNECTED LOAD: 46414 VA RCPT 14098 VA 85.47% _ - 12049 VA CONNECTED LOAD: 37376 VA KTCH 2220 VA 65.00% 1443 VA ESTIMATED DEMAND: 44790 VA -Y SPEC 3598 VA 100.00% 3598 VA ESTIMATED DEMAND: 31102 VA _ _ CONNECTED CURRENT: 129 A KTCH 12077 VA 65.00% VA CONNECTED CURRENT: 104 A A_TEST. DEMAND CURRENT: 124 A _7.8_50 EST. DEMAND CURRENT: 86 A N 5 _ NOT 1. (3 #10 CU , ( ) #10 CU E . IN 3/4"C 1. (2) #10 CU, (1) #10 CU EG. IN 3/4" C 5 2. GFCI BREAKER 2. GFCI BREAKER PANELBOARD: D LOCATION: VOLTAGE: 208Y/120 V. 3 o 4 W. MOUNTING: RECESSED... A.I.C. RATING: 10,000 AMPS SYMMETRICAL MAIN DEVICE: 100 A MLO SPECIAL: BUS AMPS: 100 AMPS LOAD DESCRIPTION BKR P NOTES CKT AAA PHASE B kVA C E CKT NOTES P BKR LOAD DESCRIPTION TRACK LIGHTS @ BAR... 20 A 1 2 A 1 1 0.1 0.1 �,kVA , -,; r_ r w 2 1 -- -- 1 20 A TRACK LIGHTS @... TRACK LIGHTS @ ENTRY 20 A 1 1 3 0.1 0.0 " „;" : 4 5 7 1 20 A DINING LIGHTS (PENDANT)_ TRACK LIGHTS @ BAR... 20 A 1 5 5 0.0 0.0 0.1 0.1 6 1 1 20 A DINING LIGHTS (PENDANT) TRACK LIGHTS 20 A 1 SPARE 7 0.1 0.0 � 0.0 8 10 _13 15 1 1 20 A 20 A TRACK LIGHTS @ ENTRY ENTRY LIGHTS TRACK LIGHTS 20A 1 9 0.1 DINING LIGHTS 20 A 1 SPARE 11 20 A 0 1 0 0 12 KITCHEN LIGHTS SITE LIGHTING_ - 1 20 A TRACK LIGHTS @ WAITING DINING LIGHTS 20 A 1 _ 1 -- -- 13 0.1 0.1 ,.;. 20 A 14 20A 1 1 20 A DINING LIGHTS BAR LIGHTS 20 A 1 -20 A 150.1 20 A 0.1 16 15 1 20 A _ TRACK LIGHTS @DINING DINING LIGHTS 20 A 1 NEON OUTLET 17 SPARE 0.1 0.1 18 25 -1 1 20 A TRACK LIGHTS @ DINING EMERGENCY/EXIT... 20 A 1 L 1,2 19 0.5 0.0 _: ', •' M„ung 20 P R 0 0 1.5 , 1 1 20 A I DO NOT USE DINING / WAITING FANS 21 A 10 A NEON OUTLETS _ TOTAL LOAD: TOTAL AMPS: 1 kVA 0 kVA 0 kVA 8A 3A 4A 29 .. 0.1 0.5. 30 _ LOAD CLASSIFICATION _ RESTROOM LIGHTS CONNECTED TOWER LIGHTS DEMAND ESTIMATED 20 A 31 PANEL TOTALS Lighting -- _ _ 222 VA _ 125.00% 278 VA 20 A 1 _ 33 -� 34 Other 20 A NEON OUTLET 447 VA VISUAL PAGING 100.00% 447 VA 22 CONNECTED LOAD: 1794 VA_ LITES__ 1 3 20 A 30 A 1138 VA VISUAL PAGING 20A 1 _ VISUAL PAGING 20A 1 125.00% 1423 VA 1 ESTIMATED DEMAND: 2132 VA 24 _ TOTAL LOAD: _TOTAL AMPS: 9 kVA 8 kVA 12 kVA 72A 65A 105 A 1 20 A HAND DRYER - RESTROOMS _ _ CONNECTED CURRENT: 5 A CONNECTED DEMAND ESTIMATED PANEL TOTALS EST. DEMAND CURRENT: 6 A NOTES: 1. PROVIDE HANDLE LOCK -ON DEVICE. 2. NON -DIMMED & NON -SWITCHED CIRCUIT FOR EM ERGENCY LIGHTING, PANELBOARD: S LOCATION: VOLTAGE: 208Y/120 V. 3 o 4 W. MOUNTING: SURFACE... A.I.C. RATING: 65,000 AMPS SYMMETRICAL MAIN DEVICE: 225 A MLO SPECIAL: BUS AMPS: 225 AMPS 1. GFCI' BREAKER: 2. (3) #10 CU , (1) #10 CU EG. IN 3/4" C 3. (3) #8 CU , (1) #10 CU EG. IN 3/4" C 4. (2) #8 CU , (1) #10 CU EG. IN 3/4" C PANELBOARD: E LOCATION: VOLTAGE': 208Y/120 V. 3 o 4 W. MOUNTING: SURFACE.., A.I.C. RATING: 65,000 AMPS SYMMETRICAL MAIN DEVICE: 225 A MLO SPECIAL: BUS AMPS: 225 AMPS 2.COORDINATE INSTALLATION REQUIREMENTS WITH SIGN SUPPLEIER. &THESE CIRCUITS ARE ROUTED THROUGH SMART BREAKER, ZONE A, TC2-CB 4.PROVIDE HANDEL LOCK -ON DEVICE. PANELIBOARrL): POS LOCATION: VOLTAGE: 120V1240 V. 1 o 3 W. MOUNTING: SURFACE NE... A.I.C. RATING: 65,000 AMPS SYMMETRICAL MAIN DEVICE: 30 A MAIN CB SPECIAL: BUS AMPS: 100 AMPS LOAD DESCRIPTION LOAD DESCRIPTION BKR P NOTES CKT A VA PHASE B kVA C" VA CKT NOTES P BKR LOAD DESCRIPTION P BKR LOAD DESCRIPTION ER LI 2 A 1 1 1 3 10.210.1 v„ u, m 0.3 0 0 21 4 1 -- -- 20 A DISPLAY AND PREP LIGHTS FACP 20 1 4 -- SPACE 1 TOWER CTS A 20fV 1 1 5 7 0.2 2.51 0.2 2.5,....4..-'_ 6 8 4 2 20 A MECHANICAL ROOM HEATEI 5 TO O A 1 1_ 0.0 0.0 EXTERIOR LIGHTS 20 A 1 1 _ 9 =' 0.1 0.0 10 1 _ 20 A SPARE „ EXTERIOR BLDG. LI LIGHTS EXTERIOR LIGHTS 0 2 A 1 20 A 1 1 1 _13 15 0.9 0.5 0.1 0.0 0.2 1.1 µ.' 12 14 16 1 1 1 20 A PREP AREA & OFFICE... 20 A SPARE NIGHT LIGHT /... 20 A 1 5 20 A _- ROOF OUTLET 20 A KITCHEN LIGHTS SITE LIGHTING_ - 20 A _ 1 20 A 1 1 _ 17 19 0.2 0.7 0.8 0.0 18 20 _ 1 -- -- 20 A -- NEON OUTLETS SPACE 20 A SPARE 20A 1 13 21 .,w, 0.0 0.4 22 _ 2 1 -20 A SIGN NEON OUTLETS 20 A SPARE 20A 1 15 23 "��� , 0.0 0.7 24 1 20 A NEON OUTLET 20 A SPARE 20 A 1 17 25 0.0 0.2 26 _�- 1 20 A -- JUKE BOX HOTWELL -SINGLE SPARE 20A 1 _ 27 P R 0 0 1.5 , 28 1 20 A DINING / WAITING FANS 21 A 10 A NEON OUTLETS _ 20 A 1 UNDERCOUNTER HEAT... 29 .. 0.1 0.5. 30 _ 1 20 A _ RESTROOM LIGHTS 1 TOWER LIGHTS 20 A 1 20 A 31 0.3 0.5 32 1 20 A_ DISH ROOM &PREP LIGHTS _ TV OUTLET 20 A 1 _ 33 0.9 0.7 34 1 20 A NEON OUTLET 1 VISUAL PAGING 20A 1 22 35 37 39 41 0.511.6 0.5 3.238 0 5 3.2 a e. ...- 1.1 3.2 36 40 42 1 3 20 A 30 A TIN CEILING OUTLETS FAN CONTROL CENTER LC SYSTEM VISUAL PAGING 20A 1 _ VISUAL PAGING 20A 1 _ WATER SOFTENER 20 A 1 1 23 0.7 1.0 24 _ TOTAL LOAD: _TOTAL AMPS: 9 kVA 8 kVA 12 kVA 72A 65A 105 A 1 20 A HAND DRYER - RESTROOMS _ _ 20A LOAD CLASSIFICATION_ CONNECTED DEMAND ESTIMATED PANEL TOTALS 20 A Lighting MECH, ROOM GENERAL... 20 A 601 VA _125.00% 751 VA 28 1 1 20 A Other _ VESTIBULE HEATER 25 A 12800 VA 2 _100.00% 12800 VA 30 LOAD: 28518 VA -- RCPT 20 A U/C REFRIG 9452 VA 100.00_% 9452 VA ___ _CONNECTED ESTIMATED DEMAND: 30105 VA LITES 843 VA 125.00% 1054 VA CONNECTED CURRENT: 79 A 2 SPEC CHEESE MELTER HOTWELL-SINGLE 5212 VA 1 124.5.5% _ 6492 VA 1.7 1.8 EST._ DEMAND CURRENT: 84 A KTCH 126 VA- 65.00% 82 VA 1 1 35 s 2.0 0.6 36 �1THTI!SCIRCUTS�ARE OUT �THRO`UH MARTREAKER, ONE A, TC3-CB.'V5 1 20 A 2.COORDINATE INSTALLATION REQUIREMENTS WITH SIGN SUPPLEIER. &THESE CIRCUITS ARE ROUTED THROUGH SMART BREAKER, ZONE A, TC2-CB 4.PROVIDE HANDEL LOCK -ON DEVICE. PANELIBOARrL): POS LOCATION: VOLTAGE: 120V1240 V. 1 o 3 W. MOUNTING: SURFACE NE... A.I.C. RATING: 65,000 AMPS SYMMETRICAL MAIN DEVICE: 30 A MAIN CB SPECIAL: BUS AMPS: 100 AMPS LOAD DESCRIPTION BKR P NOTES CKT A B C CKT NOTES P BKR LOAD DESCRIPTION HOSTESS STAND _ 20 A 1 1 1 1 0.4 0.4 , . 0.9 0 7 - 0.9 1 7 2 1 1 20 A P.O.S. TERMINAL, PRINTER1 OFFICE COMPUTER _ 20 A 1 1 3 0.4 0.0 4 _ 1 20 A SPARE- P.O.S. PRINTERS 20 A 1 -1 5 5 0.0 0.0 _ 6 .-. 1 . 1 20A P.O.S. TERMINAL, PRINTER1 SPARE 20 A REACH -IN REFRIGERATOR 20 A 7 0.0 0.0 „ 8 8 _. - 1 20 A SPARE SPARE -- 20 A 1 PLATE CHILLER 9 0 0 0.0 10 9 1 20 A SPARE SPARE _ 20 A 1 44303 VA 11 LOAD CLASSIFICATION_ 0.0 0.0 12 1- 1 20 A P.O.S. TERMINAL, PRINTER1 SPARE_ _ 20 A 1 2 13 0.0 0.0 20A 14 KTCH _ 1 20 A SPARE SPARE _ 20 A 1 ., ......., 15 m 0.0 �' 0.4 16 _ 1 _ 1 20 A P.O.S. PRINTERS SPARE 20 A 1 - 17 , ." -. 0.0 0.0. 18 _ 1 20 A SPARE 20 A HOTWELL -SINGLE _ TOTAL LOAD: 2 kVA 1 kVA 0 kVA 1 - f 0.9 0.7 16 1 TOTAL AMPS: 21 A 10 A 0 A- LETTUCE CRISPER UNDERCOUNTER HEAT... LOAD CLASSIFICATION - 1 CONNECTED_ DEMAND ^' "m, , W.�e " .., 1.1 0.7 _ ESTIMATED 1 _ - PANEL TOTALS RCPT 20 A REFRIG. DISPLAY _ 3480 VA 100.00% 1 3480 VA 19 _ - _ BREAD WARMER 20A - CONNECTED LOAD: 3480 VA_ 1 21 0.9 1,5 22 2 _ 25A ESTIMATED DEMAND: 3480 VA _ 20 A 1 1 23 0.7 1.0 24 -- CONNECTED CURRENT: 17 A 1 20 A HAND DRYER - RESTROOMS SPARE 20A 1 25 EST. DEMAND CURRENT: 17 A NOTES: 1. CONNECT TO ISOLATED GROUND BAR. PANELBOARD: C LOCATION: VOLTAGE: 208Y/120 V. 3 o 4 W. MOUNTING: RECESSED... A.I.C. RATING: 65,000 AMPS SYMMETRICAL MAIN DEVICE: 225 A MLO SPECIAL: BUS AMPS: 225 AMPS LOAD DESCRIPTION BKR P NOTES CKT A B C CKT NOTES P BKR LOAD DESCRIPTION HOTWELL-SINGLE 20 A 1 1 1 1 1 3 0.9 0 7 - 0.9 1 7 2 4 1 _ 37.8 kVA RTU -4 -� 1 20 A POTATO WARMER - UC REFRIG. 20 A 1 1 20 A POTATO WARMER MICROWAVE 20A 1 1 5 �`' 2 0 0 4 6 1 1.0 0.0 ;,', 1 20 A MEAT COOLER OUTLETS REACH -IN REFRIGERATOR 20 A 1 1 7 0.9 0.9 ";"' 8 1 30 A 20 A 1 20 A PLATE CHILLER FUTURE LARGE 14 16 18 3 15 A TVSS - FRONT ENTRANCE BLDG.... 9 0.0 1.2 10 TOTAL_ LOAD: TOTAL AMPS: 3 kVA 1 2 kVA 0 kVA 1 31 A I 19A_-, 3 A 44303 VA LOAD CLASSIFICATION_ MICROWAVE OVEN11 30 A 2 2 0.0 1.2 12 2 112.52% 2 20A TRIPLE HOT WELL KTCH _ 50289 VA RCPT 32688 VA EST. DEMAND LOAD: ., ......., _ 100.00% 3480 VA CONNECTED LOAD: 5888 VA CONN. CURRENT: 1111 A FLY FAN @ REAR DOOR 20 A 1 1 13 0.7 1.7 , ._s • "' 14 1 1 20 A HOTWELL -SINGLE REACH -IN REFRIGERATOR 20A 1 1 15 0.9 0.7 16 1 1 20 A LETTUCE CRISPER UNDERCOUNTER HEAT... 20 A 1 1 17; ^' "m, , W.�e " .., 1.1 0.7 18 1 1 20 A REFRIG. DISPLAY MICROWAVE 25A 1 1 19 0.2 1.5 20 BREAD WARMER 20A 1 1 21 0.9 1,5 22 2 2 25A PROOFING CABINET REFRIG. DISPLAY 20 A 1 1 23 0.7 1.0 24 1 20 A HAND DRYER - RESTROOMS SPARE 20A 1 25 0.0 1 0 >„ _ 26 1 20 A HAND DRYER - RESTROOMS MECH, ROOM GENERAL... 20 A 1 27 0.4 0.2 28 1 1 20 A REFRIG. EQ. STAND VESTIBULE HEATER 25 A 2 2 29-� "g, �� �` 2 0 0 5 30 1 1 20 A U/C REFRIG ___ 2 2 25 A CHEESE MELTER HOTWELL-SINGLE 20 A 1 33 1.7 1.8 34 MICROWAVE 25A 1 1 35 s 2.0 0.6 36 1 1 20 A REACH -IN REFIGERATOR SPARE 20 A 1 37 0.0 1.0 ..... . ........ , 38 1 1 20 A BACK DOOR SECURITY... - 392 0 1 5 40 1 1 20 A BACK BAR /STAR BAR... WATER HEATER 30 A 2 3 41 „ 2.0 1.7 42 1 1 20A COOK AND HOLD OVEN SPARE 20 A 1 43 0.0 1.544 44 SPARE 20 A 1 45 0.0 1.5 , � �' 46 _ 2 20 A EXTERIOR WAITING HEATER _ DECARBONIZING TANK 20 A 1 _ 47F 1.0 1 5 48 2 20A EXTERIOR WAITING HEATER REMOTE CONDENSING 49 2.3 1.5 50 25A 3 51 2 3 1 5 52 UNITS 53 ` 31 2.3 1.5 54 2 20 A EXTERIOR WAITING HEATER TOTAL LOAD 18 kVA 20 kVA 22 kVA AMPS: 153 A 173 A 188 A LOAD CLASSIFICATION _TOTAL CONNECTED DEMAND ESTIMATED PANEL TOTALS Lighting 1540 VA 125.00% 1925 VA Other 34486 VA 100.00% 34486 VA CONNECTED LOAD: 61094 VA _ RCPT 8520 VA 100.00% 8520 VA ESTIMATED DEMAND: 56197 VA SPEC 1704 VA 100.00% 1704 VA CONNECTED CURRENT: 170 A _ KTCH 14991 VA 65.00% 9744 VA EST. DEMAND CURRENT: 156 A O 1. GF61 BREAKE 5 2.(2) #10 CU, (1) #10 CU EG. IN 3/4" C 3. (3) #10 CU , (1) #10 CU EG. IN 3/4" C PANELBOARD: IG LOCATION: VOLTAGE: 208Y/120 V. 3 0 4 W. MOUNTING: SURFACE... A.I.C. RATING: 65,000 AMPS SYMMETRICAL MAIN DEVICE: 100 A MLO SPECIAL: BUS AMPS: 100 AMPS LOAD DESCRIPTION BKR P NOTES CKT AkVA PHASE B kVA CAS CKT NOTES P BKR LOAD DESCRIPTION T-.__ SPARE 20 A 1 18.1 kVA RTU -1 1 0.0 1.1 " g 2 1,3 1 20A BUILDING SIGN EXTERIOR SPARE 20 A l _ 37.8 kVA RTU -4 -� 3 „• , 0.0 0.0 '' 4 1 20 A SPARE - SPARE Y SPARE 20 A 20 A 1 1 9 225 A 3_ 225 A 5 7 x r' � EF „ 0.0 OA 0.0 0 0 5 ; �, , -.,''' � 6 8 0 A 1 20 A SPARE 1 20 A SPARE _ EXTERIOR LED A 1 1,3 9 1.0 0.0 ;,', 10 1 20A SPARE ..._..__ SPARE _20 20 A 1 CONNECTED 11 s,F �4.•.< `" 0.0 0.0 12 1 20 A SPARE 5 KVA UPS / PANEL POS 30 A 20 A 2 1 1,2,3 13 15 17 2.4 0.0 .e.. w._., ...,. 1.1 0.0 „•,' 0.4 0.0 14 16 18 3 15 A TVSS - FRONT ENTRANCE BLDG.... _ RCPT TOTAL_ LOAD: TOTAL AMPS: 3 kVA 1 2 kVA 0 kVA 1 31 A I 19A_-, 3 A 44303 VA LOAD CLASSIFICATION_ LITES CONNECTED 125.00% DEMAND ESTIMATED PANEL TOTALS Other 10481 VA 112.52% 2513 VA - CONN. LOAD: 100,00% 2513 VA KTCH _ 50289 VA RCPT 32688 VA EST. DEMAND LOAD: 3480 VA _ 100.00% 3480 VA CONNECTED LOAD: 5888 VA CONN. CURRENT: 1111 A - EST. DEMAND... ESTIMATED DEMAND: 5888 VA - CONNECTED CURRENT: 16 A NOTES: 1. DESIGN BASED UPON USE OF INTEGRATED RATED RATED BREAKERS TO ALLOW USE OF 10K AT BRANCH PANELS. PANELS INTEGRATED EQUIPMENT RATING SHALL BE 65K. 2. PRESSURE SWITCH WITH CURRENT LIMITING TYPE FUSES. 3. PROVIDE SHUNT TRIP BREAKER TYPE: 'ED -SHUNT TRIP' EST. DEMAND CURRENT: 16 A NOTES: 1. THESE CIRCUTS ARE ROUTED THROUGH SM ART BREAKER ZONE A. TC1.CB 2. COORDINATE INSTALLATION REQUIREMENTS WITH SIGN SUPPLIER. 3. NEON/LED TRANSFORMERS ARE UL 2161 LISTED AND PROVIDE SECONDARY GROUND FAULT PROTECTION ALL GROUNDING FOR THESE CIRCUITS SHALL BEISOLATED AND DEDICATED COORDINATE WITH SIGN/NEON/LED INSTALLER. DISTRIBUTION PANEL: MDP LOCATION: VOLTAGE: 208Y/120 V. 3 e 4 W. MAIN DEVICE: MLO ALC.... 65,000 AMPS SYMMETRICAL BUS AMPS: 1000 AMPS SPECIAL: JOB # 170509 SECTION No. 1 CKT FRAME POLES RATING - KVA DESCRIPTIOWNAMEPLATE NOTES 1 60 A 3 60 A 17.6 kVA DISH MACHINE 2 60 A 3 - 60 A 18.1 kVA RTU -1 3 100A 3 - 90A 25.9 kVA RTU -2 _ 4 100A 3 A 25.9 kVA RTU -3 --- _ _90 5 200 A 3 125 A _ 37.8 kVA RTU -4 -� 6 100A 3_ 90 A 25.9 kVA RTU -5 7 225 A--8 225 A _ 46.4 kVA PANEL A 8 225 A_ 3225 A 37.4 kVA PANEL B 9 225 A 3_ 225 A 61.1 kVA PANEL C 10 100A 3 100 A -1.8 kVA PANEL D - 2 11 225 A 3 225 A _ 28.5 kVA PANEL E 12 100A 3 100A _5.9 kVA PANEL IGTV( SSS 13 225 A 3 225 A 51.7 kVA PANEL S 3 14 100 A 3 100 A 24.1 kVA I BOOSTER HEATER LOAD CLASSIFICATION CONNECTED DEMAND - ESTIMATED PANEL TOTALS Li htmg 2363 VA� 125.00% 2953 VA Other 260292 VA 100.00% 260292 VA _ RCPT 78606 VA 56.36% 44303 VA LITES 1973 VA 125.00% 2466 VA SPEC 10481 VA 112.52% 11794 VA - CONN. LOAD: 400206 VA KTCH _ 50289 VA 65.00% 32688 VA EST. DEMAND LOAD: 351769 VA _ CONN. CURRENT: 1111 A - EST. DEMAND... 976 A NOTES: 1. DESIGN BASED UPON USE OF INTEGRATED RATED RATED BREAKERS TO ALLOW USE OF 10K AT BRANCH PANELS. PANELS INTEGRATED EQUIPMENT RATING SHALL BE 65K. 2. PRESSURE SWITCH WITH CURRENT LIMITING TYPE FUSES. 3. PROVIDE SHUNT TRIP BREAKER TYPE: 'ED -SHUNT TRIP' 100 S. Ashley Dr., Ste. 100 Tampa, FL 33602 P: 813 - 323 - 9233 Lic. #: AA - 0003590 W: www.bdgllp.com J ~ D Cy) 0 m Q w0 Z I.I.. W U 0 � W Z LL �z 0 cn 0 THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER "PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF BDG ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS, ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR RELATED TO THE PLANS., ANY DISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. Adam T. Powell, PE PE0073853 LECTRICAL SEAL 1/4/201810:33:17 AM ISSUE BY I DATE DESCRIPTION 1 08-24-2017 PERMIT COMMENTS 3 10-16-2017 OWNER COMMENTS 5 01-04-2018 Revision 5 PROJECT INFORMATION BLOCK JOB # 170509 DATE: 7-6.2017 DRAWN BY: Author CHECKED BY: Checker SHEET TITLE ELECTRICAL SCHEDULES SHEET NUMBER L E601 - I ITEM # QUANTITY DESCRIPTION MANUFACTURER and MODEL # ELECTRIC GAS WATER WASTE COMMENTS ITEM # QUANTITY DESCRIPTION MANUFACTURER and MODEL # ELECTRIC GAS WATER WASTE COMMENTS SEE SHOP DRAWINGS FOR EXACT ELECTRICAL REQUIREMENTS 208V/3PH 12 6 AMPS PLUMBING CONTRACTOR FURNISH AND INSTALL CONDENSATE LINES 73. CLEAN DISH TABLET 3 COMPARTMENT SINK ASSEMBLY CUSTOM 1 A, WALK-IN FREEZER _ KOLPAK 208VI1PH 8.7 AMPS FD ELECTRICIAN PROVIDES AND INSTALLS HEAT TAPE FOR DRAIN LINES .112" CW 112" HW FS PLUMBER TO PROVIDE AND INSTALL STANDOFF SUPPORTS FOR DRAIN LINES _ - 3 ELECTRICIAN BPLUMBERTOCONNECT PC TO RUN DRAIN LINE 208V/3PH 7 4 AMPS 1B. WALK-IN BEER COOLER _ KOLPAK 2081PH 7.9 AMPS FD 74. 2 EA. ICE MACHINES SCOTSMAN EH430SL•1 120V 15 AMP BREAKER 112,CW OD 4") REMOTE CONDENSER REQUIREMENTS SEPARATE 208V/8PH8 8 AMPS 1C, WALK-IN PRODUCTION COOLER _ KOLPAK 115V11PH4.0AMPS FD 74A. 2EA. REMOTE CONDENSING UNITS SCOTSMAN.ECC1800-3 - 208V13PH19AMPS -_- -zosv/aPH a e AMPS 1D. WALK-IN MEAT COOLER _ KOLPAK 115VNPH 4.0 AMPS FD _ 75. ICE BIN Follet SG3200.72 FS TROUGH DRAIN 76. POWER HUB - UNIVEX PM -91 WINS -9 CHOPPER ATTACHMENT 120V t HP 2, 4 EA, PLASTIC STRIP CURTAINS CURTRON M108PR-4080 _ � 3, GRIDDLE ACCUTEMP EGF208363650-T1 208V13PH 39,56 AMPS 77. 2 EA. BAG -IN -BOX RACKS COCA-COLA 1 CORNELIUS4. CHAR CHAR BROILER VULCANVACB36 314" 102,000 BTU _ 7$. IEA, CARBONATOR -_ COCA-COLA MCCANNSES30091 120V7AMPS, 120V8.3AMPS 112'CW(FROM FILTER) VERIFY ALL DRINK SYSTEM REQUIREMENTS WITH COCA-COLA REPRESENTATIVE lOO S. ASiII@y 813 - 323 - 9233 5. 2 EA. _ CHAR BROILER VULCAN VAC847 314" 136,000 BTU 7$A. 1 EA. _ SIS CARBONATOR SHELF COCA-COLA McCANNS #16.1446 - S1'@. 100 LIC. EPALD #: AA - 0003590 - - - Tampa,. FL 33602 W: www.bdgllp.com 6A, REFRIGERATED EQUIPMENT STAND WIDRAWERS &CASTERS SILVER KING SKRC879H 120V 3.1 AMPS _ SPECIAL TEXAS ROADHOUSE CONFIGURATION (PANS SIDE X SIDE) 79, WATER FILTRATION SYSTEM EVERPURE C820.312 (FOR SODA SYSTEM _ 314"CW FURNISHED 8Y COCA-COLA WIDRINK SYSTEM 68. REFRIGERATED EQUIPMENT STAND WIDRAWERS &CASTERS SILVER KING SKRC850H 120v 3.1 AMPS SPECIAL TEXAS ROADHOUSE CONFIGURATION (PANS SIDE X SIDE) $O, 1 LOT SHELVING PACKAGE METRO -FOR WALK-INS ABC PROCURMENT C -K FOR DRY STORAGE ALL WIRE SHELVING EPDXY COATED 6G.• SPECIAL TEXAS ROADHOUSE CONFIGURATION PANS SIDE X SIDE) T $1, 1 LOT _ DUNNAGE RACKS NEW AGE MODEL 20XX ��__-"�--------� SPECIAL TEXAS ROADHOUSE MODEL 7. GRIDDLE COUNTER TOP 24" STAR MFG. 524TGF-DIV 208V11 PH 28,9 AMPS �-_- CORD AND PLUG BY ELECTRICIAN $2. 1 LOT STEAM TABLE PAN RACKS NEW AGE 1505 $, COUNTER TOP COLD PAN CUSTOM STAINLESS STEEL $3. 1 LOT SHEET PAN RACKS NEW AGE #7331 WICASTERS - _ - 9, 2 EA. 14" DEEP FRYER WICASTERS PITCO SG -14S 314" 110,00OBTUs $3A. 1 EA COUNTER HEIGHT SHEET PAN RACK WIWORK TOP NEW AGE #1313 WICASTERS 205 N. ARMENIA AVE; #102 TAMPA, FL 33609 10. 2 EA. 18" DEEP FRYER WICASTERS _ PITCO SG -188 _ 39" 140,000 Bios 84. _ DECARBONIZING TANK CLEAN X -PRESS CLEAN7ANK CXP006 - 120v 8.3 AMPS - TEL (813) 995-0300 _ FAX (813).995-0400 10A. FRYER FILTER WICASTERS PITCO P-18 120V to AMPS $5. _ug BEER KEG DOLLIES &STACKERS MICROMATIC KD300, KS200 FLORIDA ENGINEERING BUSINESS #002764 ..- - - ---- COPYRIGHT 2016 •EMERALD ENGINEERING 11. ONION BREADING STATION CUSTOM STAINLESS STEEL $6. POT FILLER T&S B•0597 1/2"l _ 11A, _REFRIGERATED STAND _ SILVER KING SKRCB50HIC11 120V 3.1 AMPS ON CASTERS $7. BEER LINES RUN THROUGH UNDERGROUND CHASE FROM INSIDE BEER WALK-IN _ 12, _ UPRIGHT REACH -IN FREEZER W/CAST_ERS TRAULSEN TR1G•12000 _ 120V 9.7 AMPS ON CASTERS $$. GLYCOL BEER CHILLING SYSTEM CHILL -RITE MLN -33 120V 12 AMPS TO DESIGNATED AREA INSIDE BACK BAR 13. SALAD PASS THROUGH PICK-UP SHELF CUSTOM $$A. - BEER CHILLING SYSTEM SHELF CHILL -RITE - _14, _ 3 EA. - _MICROWAVE OVENS MENUMASTER MFSI2TS - 120v 15 AMPS 89• 14A. 90. SIS DRINK COUNTER CUSTOM I I I Q 15. REACH -IN REFRIGERATOR WICOLD TOP, CASTERS TRAULSEN UST7230•zTR01-LR 120V 7.5 AMPS 91. GLASSWARE RACKS W%A. T le ) 16, UNDERCOUNTER REACH -IN FREEZER TRAULSENULT27 120V7.5AMPS MODIFIED WITH WORK TOP - 92. 17. LETTUCE CRISPER - SILVER KING SK2SB 120V 2,4 AMPS PROVIDE WALL MOUNTING BRACKET 93. 2 EA. ICED TEA BREWERS BUNN TBQ-3 120V 15 AMPS 112"CW FOR ALL DRINK EQUIPMENT _ r. 18• 94. SIS DRINK COUNTER � CUSTOM J N 19. REFRIGERATOR WICOLD TOP, CASTERS TRAULSEN UST279-D 120V 7,5 AMPS -_ ON CASTERS. 95, 2 EA, SODA DISPENSERS COCA COLA BEV-OLUTION DROP-IN WIFS CABINET #44610 120V 12 AMPS 112"CW FILTERED FS PLUMBING CONTRACTOR TO PROVIDE BACK FLOW PREVENTORS -20. MONKEY DISH SHELF CUSTOM STAINLESS STEEL 96, SIS DRINK COUNTER _ CUSTOM O 21. _ PASS THROUGH PICK-UP SHELF WIHEATLAMPS SEE 21A & 21C FOR HEAT LAMP SPECS 97. _ 1 EA. COFFEE MAKERS -- BUNN CWTF-TC --- 120V 11,4 AMPS 112"CW '- --` (2) fiRAL-96 208V 10/120V/1PH 18. 9A G(a) GRAL-48ll6 208v 10/120V 8.9A VERIFY CONFIGURATION WITH EQUIPMENT SUPPLIER � 9$. 1 LOT ALUMINUM OVERSHELF WIUTENSIL RACK NEW AGE 112*PR 21A, ASSEMBLY COUNTER HEAT LAMPS HATCO: GRAL-96 2 EA.) GRAL-48D6 4 EA.) 1:1AHL-42D3 1 EA. Lim - V 10/1PQ ILA 2113 99. 1 LOT- ALUMINUM WALL SHELVES NEW AGE 9728* _- � O SPECIAL INVERTED BRACKETS 21 C. PLATE SHELF HEAT LAMP AND LIGHT BOX _ HATCO GRAH-36D31 EA. HATCO HL -24 1 EA. i is iiNH aeo wArrs --_ - 100. S15 POS STAND ADVANCE TABOO EK -SS -244M �7 Z LL 22, 3 EA. 10 BUTTON MERIDIAN TIMER 22A. _ 8 BUTTON ZAP TIMER - _- - 120V 102. UNDERCOUNTER REFRIGRATOR COMPACT - BEVERAGE AIR VCR27 WI LOW PROFILE CASTERS 120V 4 AMPS � V 2213. 4 BUTTON ZAP TIMER 120V WW 22C. 3 EA. 12 BUTTON ZAP TIMER 120V UIC R TRAULSEN 7 120V .AMPS _ �✓ ♦ z O `- - INDIRECT CONNECTION TO FLOOR SINK •COPPER PIPING ONLY!II 23. TRIPLE HOT WELLS WIDRAIN WELLS MOD•3007DM 1PH zoavhPH 10.3 AMPS Fs DRAIN LINE AND BALL VALVE BY PLUMBING coNrRAc10R CORD BY ELECTRICIAN 105. FLY FAN BERNER SHC07.1048AA•P 120W1PH 314 HP Z 24. STEAM TABLE COUNTER WIFAUCET CUSTOM STAINLESS SPECIALTIES T&S B-0208 112"HW 1.112"OD EXTEND TO FLOOR SINK -COPPER PIPING ONLYII! 1.06. O 120V 665 WATTS 25, POTATO WARMER WIWARMING SHELF AND HEAT LAMPS CUSTOM WIHATCO GRSBF-30-I & HATCO GRA -30D3 120V 900 WAI r S _ CORD BY ELECTRICIAN 107._.- _- PLUMBER TO PROVIDE DRAIN LINE FOR ALL KITCHEN CORNERS AND GAPS BETWEEN WALK-INS AND WALLS W 26. 2 EA. COLD WELL DROP-IN CUSTOM -STAINLESS SPECIALTIES FS FOR INDIRECT CONNECTION TO FLOOR DRAIN •COPPER PIPING ONLY! 108. i LOT SIS CORNER GUARDS AND TRIM PIECES CUSTOM - _ INDIRECT CONNECTION TO FLOOR SINK •COPPER PIPING ONLYII �- 27, HOT WELL W/DRAIN WELLS MOD•100TD -- 120V 13.8 AMPS FS DRAIN LINE AND BALL VALVE BY PLUMBING CONTRACTOR CORD BY ELECTRICIAN 109. 28. 2EA. DIPPER WELL COMPONENT HARDWARE K30-1010 112"1 PC TO PROVIDE INDIRECT CONNECTION TO FLOOR DRAIN -_- 110. P05TERMINALS - OWNER SUPPLIED - 120V2AMPS ISOLATED GROUND - 29. _ SIS ASSEMBLY TABLE CUSTOM - POS PRINTERS OWNER SUPPLIED --_ 120V 1 AMP ISOLATED GROUND 30. 112. CASH DRAWERS OWNER SUPPLIED - 30A. 113, 31, _ 2 EA. CHEESE MELTER _ VULCAN HART 1036C 208VI1PH 17,3 AMPS ELECTRICIAN TO INSTALL NEW CORD AND PLUG 70 REACH OUTLET IF REQUIRED 114, 1 EA. SIS FLOOR TROUGH 96"X 8" GRATE - STAINLESS DRAINS 4'OD, -FURNISHED AND INSTALLED BY PLUMBER THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER 32, � COOK AND HOLD OVEN ON CASTERS .ALTO SHAM 150•TH•1 1 208V iPH 14.5 AMPS ON CASTERS WITH POLY CUTTING BOARD TOP 115. _ _I 1 EA, SIS FLOOR TROUGH 72" X B" GRATE STAINLESS DRAINS � 4"OD FURNISHED AND INSTALLED BY PLUMBER "PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG - ARCHITECTS. AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR - _.__ _ 4"00 FURNISHED AND INSTALLED BY PLUMBER USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF BDG 33. BUN TOASTER STAR BG -3 120y 14,6 AMPS INSTALL SIS SIDE PANELS 116. 1 EA. SIS FLOOR TROUGH 36" x 4" GRATE STAINLESS DRAINS � ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE 34. SIS SALAD PICKUP TABLE CUSTOM - 117. 1 EA SIS FLOOR TROUGH 60" X 8" GRATE _ STAINLESS DRAINS 4"OD FURNISHED AND INSTALLED BY PLUMBER SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS TUBULAR SUPPORTS IN ALL LOCATIONS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS, 35, 4 EA. HAND SINKS ADVANCE TABOO 7 -PS -66, T&S 5F4WLX03 112"CW 112'HW 1.112"IPS INCLUDES SIDE SPLASHES FOR BOTH SIDES -ALL LOCATIONS 1.1$. POT RACK ADVANCE TABOO SW1.24 REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL ---- "�"""-"--""-""" `-'--- --- -- OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS 35A. _ EYE WASH ATTACHMENT FRONT LINE 5179 112"cw v2"Hw ATTACH To HAND SINK FAUCET 12$. _ 7 EA. EXTERIOR METAL BENCH WABASH VALLEY KE14225•T _- WITHOUT THE EXPRESS WRITTEN APPROVAL of BDG ARCHITECTS: OR ANY CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY �- TUBULAR SUPPORTS IN ALL LOCATIONS 129. ADVANCE TABOO SW1.60 35B. HAND SINK WI KNEE PEDAL _ ADVANCE TABOO 7-P5-62, T6S 5F-4WLXo3 v2^cw v2"HW 1.112•!Ps INCLUDES SIDE SPLASHES FOR BOTH SIDES -ALL LOCATIONS 2 EA, POT RACK _ REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL _ AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG 35C. HAND SINKS ADVANCE TABOO 7 -PS -23 -EC -5P, TBS 5F4WLX03 112"CW 112"H_W 1.112"IPS INCLUDES SIDE SPLASHES FOR BOTH SIDES -ALL LOCATIONS 1_3_0. _ CHICKEN PREP TABLE CUSTOM SS 18x36 - WI BACKSPLASH a CASTERS ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR 36. SIS PICK-UP TABLE CUSTOM 131. - UN E'RCDCIN'TER REF 13ERAT - DELfIELD UCD4432N 120V 3.9A RELATED TO THE PLANS. ANY DISCREPANCIES OR CONFLICTS IN THE PLANS SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR CORD BY ELECTRICIAN 132. CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER 37, 2 EA HOT WELL (SINGLE WIDRAIN) WELLS MOD-1OOTD -_- 120V 13,8 AMPS ------- _ DRAIN LINE AND BALL VALVE BY PLUMBER •COPPER PIPING ONLY/!! DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR 3$, REACH -IN REFRIGERATOR WICOLD TOP, CASTERS BEVERAGE AIR SPE60.16 12oV 9.6 AMPS DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS, THE -- '-"'--" CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING 39. S/SPICK-UP TABLE CUSTOM AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY -___ -- USE ONLY COPPER DRAIN LINES II FURNISHED $. INSTALLED BY PC SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS. 40. 2 EA, CONVECTION OVENS (DOUBLE STACKED) BLODGETT SHO•G TRH DBL v 120V 6 AMPS 3l4^ 50,000 BTU X2 - CORD AND PLUGS BY ELECTRICIAN A. _ 18" DRAIN BOARD ADVANCE TABOO CRD -18C -SS- 1"IPS ATTACH TO ADJACENT UNIT (ONE SET OF LEGS) -- -" _ - USE ONLY COPPER DRAIN LINES II FURNISHED &INSTALLED BY PC FILTER FURNISHED WITH UNIT,, INSTALLED BY PC (FLUSH WATER LINE PRIOR TO CONNEC710NI( � B. ICE BIN W17 CIRCUIT COLD PLATE ADVANCE TABOO CRI•16.36.7 41. PROOFING CABINET PIPER PRODUCTS CUSTOM RIP•1•TXR-MANUAL FILL 208VIiPH 16 AMPS TRENCH DRAIN ELECTRICIAN TO FURNISH 81NSTALL CORD &PLUG WITH SEALTIGHT 112" IPS SPEED RAIL CONTINUOUS BETWEEN ICE BIN AND DRAIN BOARD USE ONLY COPPER DRAIN LINES II 42. UIC HOT CABINET CRESCOR H -339 -SBS -1210C 120V 7.5 AMPS C. SIS SERVICE BAR TOP WIDRAIN PAN CUSTOM 112" IPS FURNISHED & INSTALLED BY PLUMBING CONTRACTOR Adam T. Powell, PE 43. SIS WORK TABLE WI OVERSHELF CUSTOM USE ONLY COPPER DRAIN LINES it FURNISHED 8 INSTALLED BY PC q 1"IPS ATTACH TO ADJACENT UNIT ONE SET OF LEGS) _- PEOO73853 - 5 .E._,._2 EA. 60" MUG FROSTIER PERLICK FR60 120V7.1 AMPS Ii " PO 44. S/S EQUIPMENT STAND WICASTERS ADVANCE TABCO ES -302--- _--------- _ ON CASTERS � F. G e COR/ a � ` � ��'ON �� ELECTRICAL SEAL 1/4/2018 10:38:40 AM ON CASTERS�r-.•`c�Ng�F``���i,� 4 BURNER RANGE VULCAN HART VHP848.0100J 314" 120,000 BTU G. 46. _ SIS WORK TABLE ADVANCE TABOO TKSS 306 - _ _-- _.- OPEN BASE ON SIDE FOR CAN RACK -H, BAR HAND SINK WISIDE SPLASHES - _ ADVANCE TABCO SC•15•TS•SS-S _ 112"CW 112"HW 1.112" IPS - FAUCET INCLUDED _ - 4$. _ UIC E AN RACK NEW AGE 1313 1' 1 - _ J. SHELF METRO 24X24 WI INLAYS K. DUMP SINK WI DRAIN BOARDS ADVANCE TABCO PRB-19.31C _ 112"CW 112"HW 1.112"IPS to FS USE ONLY COPPER DRAIN LINES !! FURNISHED 81NSTALLED BY PC 49, TILT SKILLET MARKET FORGE 1200 208V13PH 25AMPS _ T H00 /BAKERY LC SYSTEMS/ HALTON SEE LC DWGS -_- _ _ _-_ L. 1 EA. �� _SODA GUNS - - COCA-COLA --� CONTACT COKE REPRESENTATIVE FOR ANY SPECIAL REQUIREMENTS 51. - _ _ EXHAUST HOOD (COOKLINE) LC SYSTEMS/ HALTON SEE LC DWGS FD INDIRECT CONNECTION TO FLOOR SINK USE COPPER PIPE ONLYIIII SEE HOOD DRAWINGS FOR DETAILS- M. _ FROZEN COCKTAIL MACHINE - TAYLOR 428 120V 13 AMPS SELF CONTAINED COUNTER TOP UNIT 52, _ - -_ EXHAUST HOOD DISHWASHING) LC SYSTEMS SEE LC DWGS SEE HOOD DRAWINGS FOR DETAILS --- --- - _ 53. - ..._ - N. - CHILLED BEVERAGE MACHINE _ GRINDMASTER•CECILWARE D25-3 _ 120V 5,5 AMPS ISSUE BY DATE DESCRIPTION �, _ _ BREAD PICK-UP SHELF _CUSTOM •SEE ARCHITECTURAL WINDOW DETAILS FOR SIZING - � O. _ BEER TOWER 9SPIGOT UNDERCOUNTER9SPIGOT CUSTOM SIS DRIP PAN MUST BE SEALED WATER TIGHT TO BAR TOP BY INSTALLER FS USE ONLY COPPER DRAIN LINES /! FURNISHED 8INSTALLED BYPC 3 10-16-2017 OWNER COMMENTS - P. - -- - ---- COUNTER TOP LIQUOR DISPLAY -- - -- CUSTOM MILLWORK _ - 120V 1PH _- -_-- ELECTRICAL CONNECTION FOR INTERNAL LIGHTING 5 01-04-2018 R@VI510i1 5 55. _ REFRIGERATED DISPLAY CASE WI3"CASTERS _ McCRAY SC-4-SSKSD 120V 6 AMPS - -.-,-_ CORD AND PLUG 8Y ELECTRICIAN -_ - - __R __._-__._ ___.._. UNDER COUNTER REFRIGERATOR - TRAULSEN UHT27 3 120V 7.5 AMPS - SIS EXTERIOR _ 57, BAKER'S TABLE JOHN BOOS DS808-X � 5$, - _ MIXER HOBART HL600.1 208V13PH 10 AMPS _ ELECTRICIAN TO VERIFY PROPER ROTATION DIRECTION/ CORD BY ELECTRICIAN R1. _ UNDER COUNTER REFRIGERATOR TRAULSEN UHG48-LR-0100•ZTROl - 120V 7.5 AMPS SIS EXTERIOR 59. _ 3 EA. _ _ HANGING HEAT LAMPS HATCO DL-760CL 120V 250 WATTS -. -_ ON/OFF SWITCH PART OF NEAT LAMP ASSEMBLY -._ _._ S. BACK BAR ASSEMBLY SIS ( ) CUSTOM - -'-' �-- T. ___...._._ - .----- 60, MEAT GRINDER UNIVEX PM91 WI ATTACHMENTS 120V 1HR U. 61, MEAT CUTTING TABLE ADVANCE TABCO KSS -306 -_, _ - -_-_- _ _. __ V. 3 EA. -..__--_-_- SPEED RAILS SUPREME METAL SRK•3 62, MEAT TENDERIZER LUMAR IDEAL MT -M5 -TR -_ _ -__ __- _ __-- -_- _ _ PROJECT INFORMATION BLOCK W. -- -__ _- _ - -_ _ - -- -"- 63, SIS WORK TABLE ADVANCE TABCO KSS -246_--- - --_ ___ _._-- _ --- --.-- JOB # 170509 X. _...._-_ GLASS WASHER _--_ ECOLAB OMEGA 5E (JACKSON DELTA 5E) 120V 16A 112"141 HW 2`T0 F.S. COPPER SUPPLY 6 DRAIN TO FLOOR SINK BY P,C. ---- 64, SIS WORK TABLE ADVANCE TABCO KSS -306 _ _ _. -__-_._-, __ _ __ DATE: 7-6-20.17 Y. - _ - BAR TOP --- _ CUSTOM MILLWORK PACKAGE _ 65, 2 COMPARTMENT PREP SINK W/DRAIN BOARD ADVANCE TABCO FS•2-2424.24L _ 112"CW 112"HW - 1.112"OD PLUMBER TO SUPPLY -STAND-OFF SUPPORTS FOR DRAIN LINES DRAWN BY: Author _ _.- Z. BAR OVERSTRUCTURE ------ - - CUSTOM MILLWORK PACKAGE -__ - _ 66. - CHECKED BY: Checker 67, _ -- -._- SIS PREP TABLE ADVANCE TABCO KSS -307 _ _ _-__ _ --.--- _ 6$. 3 COMPARTMENT PREP SINK WIDRAIN BOARD ADVANCE TABCO FS -2-2424-24R 112"CW 112"HW 1.112"OD PLUMBER TO INSTALL STAND OFF SUPPORTS FOR DRAIN LINES _ SHEET TITLE 69, - SALAD SPINNER WICASTERS HOBART SDPS-11 - 120V 2.5 AMPS ._, _ ----- __ ___- -- ELECTRICAL KITCHEN EQUIPMENT SCHEDULE V C H E D U L E ,__ ------__.,_ ___�--___ _ 70, DIRTY DISH TABLE CUSTOM 112"CW 112"HW FS PLUMBER TO PROVIDE AND INSTALL STAND-OFF SUPPORTS FOR DRAIN LINES - ------ 71. PRE -RINSE SPRAYER BK RESOURCES BKF-IMPDR-WB-G SEE ITEM 81. -_ _ ____- _- _ - 72, 72A. DISH MACHINE _ ECOLAB ECOTEMP EC44HH 2O8VI3PH 48.75 AMPS T BOOSTER HEATER ECOLAB C24 208V 3 PH 66.7A _ 314"HW - 112" CW 112 HW FS FS BACK SIPHON PROTECTION ON WATER LINE ELECTRICIAN TO PROVIDE DISCONNECT IF REQUIRED BY CODE P.C. TO PROVIDE 314" COPPER ROUGH IN CONNECTION TO BOOSTER, ISOLATION VALVES AND 3i4" FEED TO DISH MACHINE INLET �- E602