HomeMy WebLinkAbout100 Towne Center Blvd 17-2175 (new constr)'A v
a CITY OF SANFORD
s Ztll7 BUILDING & FIRE PREVENTION
'
JULPERMIT APPLICATION
- Application No.
Documented Construction, Value: $ $1,002,000.00
Job Address: 100 Towne Centre Blvd, Sanford, 32771 Historic District: Yes ❑ No
Parcel ID: 29 19 30 504 0000 0010 Residential ❑ CommercialFX]
Type of Work: New 0 Addition ❑ Alteration ❑ Repair ❑ bemo ❑ Change of Use ❑ Move ❑
Description of Work: Construct single story restaurant building.
n ' r7._
Plan Review Contact Person: EX -A V i 6 S't 0 0 Ck Title:V.`10 ermmany\
Phone: Fax: Email:__ d o-vid . stcrck q u e .
Property Owner Information
Name Tim Barnett Phone: 502-515-7306
Street: 6040 Dutchman's Lane Resident of property? : No.
City, State Zip • Louisville, KY 40205
Name TBD
Street: N/A
City, State Zip: N/A
Contractor Information
Phone: N/A
Fax:`N/A
State License No.: N/A
Architect/Engineer Information
Name: BDG Architects Phone: 813-323-9233
Street: 100 S Ashley Dr STE 100
City, St, Zip: Tampa FL 33602
Bonding Company: N/A
Address: N/A
Fax: 813-323-9238
E-mail• gregg.holdsworth@bdgllp.com
Mortgage Lender: N/A
Address: N/A
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE- BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 516 Edition (2014) Florida Building Code
Revised: June 30, 2015 Permit Application
zi�
D
FLORIDA PRODUCT APPROVALS
PRODUCT TYPE
MANUFACTURER
MODEL #/SERIES
FL PRODUCT
APPR. NO.
EXP. DATE
MIAMI DADE
NOA
EXP. DATE
OWNER, FIXTURE, SHEET EQUIPMENT
EXTERIOR DOORS
OUTSWINGING COMMERCIAL DOOR STEELCRAFT H SERIES 17-0320:05 05-05-2018
OUTSWINGING COMMERCIAL DOOR STEELCRAFT H SERIES 15-0930.06 05-05-2020
SWINGING EXTERIOR DOOR ASSEMBLIES NYSTROM, INC. - FL 21058.1 N/A
SWINGING EXTERIOR DOOR ASSEMBLIES SPECIAL -LITE SL -17 FL 21856.1 N/A
SWINGING EXTERIOR DOOR ASSEMBLIES DETEX ADVANTEX 40 SERIES FL 19181 N/A
100 SOUTH ASHLEY DRIVE, SUITE 100
WALL PANELS
STOREFRONT KAWNEER 451 FL 14287 - R4
TAMPA, FLORIDA 33602
ROOFING PRODUCTS
SINGLE PLY ROOF ON WOOD DURO-LAST 50 MIL N/A 13-1106.03 AUG. 22, 2017
METAL ROOF ON WOOD METAL SALES MFG. CORP. ALUMINUM 5V -CRIMP FL 11560.1 - R2 N/A
ROOF HATCH BILCO NB FL 15110.2 - R1 14-070$,07
PRE-ENGINEERED AC. STANDS PRECISION ALUMINUM PRODUCTS ALUMA STAND FL 16921,2 - R2
PHONE: 813-323-9233
EXTERIOR WALLS
PHONE: 502-855-5561 (0)
FAX: 813-323-9238
PHONE: 941-387-5266 (C)
EMAIL: Monica.Jones@TexasRoadhouse.com
AIR HANDLING UNIT
FIBER CEMENT SIDING AND SOFFIT
ALLURA
PLANK/ PANEU SOFFIT
N/A
CIVIL LANDSCAPE ENGINEER
14-1022.03 1 APR. 24, 2018
OWNER & CONSULTANTS
LIi-1.01 IRRIGATION PLAN
EXIST
EXISTING
OS
A
ANNEALED
1
OWNER, FIXTURE, SHEET EQUIPMENT
ARCHITECT
STRUCTURAL ENGINEER
TEXAS ROADHOUSE
BDG ARCHITECTS
HEES & ASSOCIATES, INC
6040 DUTCHMAN'S LANE
100 SOUTH ASHLEY DRIVE, SUITE 100
1381 FIFTH STREET
LOUISVILLE, KY 40205
TAMPA, FLORIDA 33602
SARASOTA, FLORIDA 34236
CONTACT: MONICA JONES,
CONTACT: GREGG HOLDSWORTH, AIA
KARL F. HEES . S.I. F.ASCE
CON P.E
TACT:
ARCHITECTURAL DESIGN MANAGER
PHONE: 813-323-9233
PHONE: 941-955-4555 (0)
PHONE: 502-855-5561 (0)
FAX: 813-323-9238
PHONE: 941-387-5266 (C)
EMAIL: Monica.Jones@TexasRoadhouse.com
AIR HANDLING UNIT
FAX: 941-955-9333
FIBERGLASS REINFORCED PLASTIC
PTD
EMAIL: Karl@heesassociates.com
CIVIL LANDSCAPE ENGINEER
MEHCANICAL, PLUMBING,
HOOD EQUIPMENT
FIRE RETARDANT TREATED
ELECTRICAL ENGINEER
QUARRY TILE
ASPH
ASPHALT
LC SYSTEM, INC .
BOHLER ENGINEERING
EMERALD ENGINEERING, INC
DUBILIN, OHIO
3820 NORTHDALE BLVD, SUITE 300B
205 NORTH ARMENIA AVENUE, STE 102
CONTACT: KEVIN MULDOON
TAMPA, FLORIDA 33624
TAMPA, FLORIDA 33609
PHONE: 813-955-0300 (0)
PHONE: 614-235-9430
EMAIL: KMULDOON@LC-SYSTEMS.COM
CONTACT: JAMES KELLEY, PE
PHONE: 813-812-4100 (0)
PHONE: 813-758-9808 (C)
FIXTURE
PHONE: 813-955-2323 (C)
EMAIL: m.costello@emeraidmep.com
REFERENCE
EMAIL: jkeliey@bohlereng.com
CEILING
HC
SIGNAGE
FS -2.2 POS WIRING DIAGRAM + •
A-500 WALL DETAIL • + •
FEDERAL HEALTH
CONCRETE MASONRY UNIT
HDW
6040 DUTCHMAN'S LANE STE 300
REQ'D
RO
REQUIRED
ROUGH OPENING
LOUISVILLE, KY 40205
COLUMN
HM
CONTACT: STEVE MAESER
SB
SPLASHBLOCK
PHONE: 502-515-7328
CONCRETE
HT
EMAIL: smaeser@FederalHeaith.com
SYMBOLS_
WALL TYPE ELEVATION ELEVATION DATUM TAG
X '
1 DETAIL TAG
A# AlA
REVISION NUMBER
N
FINISW FINISH TAG W A1.0 E INTERIOR ELEVATION TAG
O
X KEYNOTE S
1
ROOM ROOM TAG EXTERIOR ELEVATION TAG
A1.0
XXX
T
101 DOOR TAG A1.0 PLAN DETAIL TAG
BUILDING SECTION TAG
Og WINDOW TAG A1.0
ABBREVIATION
LIi-1.01 IRRIGATION PLAN
EXIST
EXISTING
OS
A
ANNEALED
ELECTRICAL DETAILS
FD
FLOOR DRAIN
PF
AC
AIR CONDITIONING
FEC
FIRE EXTINGUISHER CABINET
PS
PRIMARY SCUPPER
ACT
ACOUSTIC CEILING TILE
FF
FINISH FLOOR
PSF
POUNDS PER SQUARE FOOT
AFF
ABOVE FINISH FLOOR
FR
FIRE RATED
PT
PRESSURE TREATED
AHL
AIR HANDLING UNIT
FRP
FIBERGLASS REINFORCED PLASTIC
PTD
PAINTED
AL
ALUMINUM
FRT
FIRE RETARDANT TREATED
QT
QUARRY TILE
ASPH
ASPHALT
GALV
GALVANIZED
R
RADIUS
KITCHEN ELEVATIONS •
A-310 WALL SECTIONS • •
GYP BD
GYPSUM BOARD
REBAR
REINFORCING BAR
CJ
CONTROL JOINT
FIXTURE
A-313 WALL SECTIONS • • •
REF
REFERENCE
CLNG
CEILING
HC
HANDICAP
FS -2.2 POS WIRING DIAGRAM + •
A-500 WALL DETAIL • + •
CMU
CONCRETE MASONRY UNIT
HDW
HARDWARE
REQ'D
RO
REQUIRED
ROUGH OPENING
COL
COLUMN
HM
HOLLOW METAL
SB
SPLASHBLOCK
CONC
CONCRETE
HT
HEIGHT
CONT
CONTINUOUS
HVAC
HEATING, VENTILATION, AIR CONDITIONING
SIM
SIMILAR
INSUL
INSULATION
SPEC
SPECIFICATION
CPT
CARPET
MAX
MAXIMUM
SS
STAINLESS STEEL
CT
CERAMIC TILE
MECH
MECHANICAL
STL
STEEL
CL
CENTERLINE
MFR
MANUFACTURER
STOR
STORAGE
DBL
DOUBLE
SUSP
SUSPENDED
DF
DRINKING FOUNTAIN.
MIN
MINIMUM
T
TEMPERED
DIA
DIAMETER
MO
MASONRY OPENING
TYP
TYPICAL
DIM
DIMENSION
MR
MOISTURE RESISTANT
UNO
UNLESS NOTED OTHERWISE
DN
DOWN
METAL
VCT
VINYL COMPOSITION TILE
DS
DS
DOWNSPOUT
NA
N A
NOT APPLICABLE
VERT
VERTICAL
EA
EACH
NOT IN CONTRACT
WD
WOOD
EJ
EXPANSION JOINT
NOM
NOMINAL
WP
WATERPROOF
ELEC
ELECTRICAL
NTS
NOT TO SCALE
WWF
WELDED WIRE FABRIC
ELEV
ELEVATION
OC
ON CENTER
EQ
EQUAL
OPP
OPPOSITE
LOCATION MAP
i
DRAWINGS DRAWINGS ISSUED DRAWINGS DRAWINGS ISSUED
3 4 5
e- N N
> > Lh q Ln > > co d Ln
> >
U) GWL' 2' W
U) wLL'
w w' O O O w w O O O
CD C/) �>>>
> > >
c,
�C)w H0wI
L)Ix Ix
W H H tY lY LY W h w CO I Ix
1-- Z Z I_- Z Z Z
w w 'S 'S w w
wan.00o Wa.aoo0
ar- ti I- rte- 00 w
.- 0-
I r :°
o o O a O h N N N N N
r N CV N CV CV r
P N N N 14 N N CCS e3
00 'SHEET# o cSHEET # SHEET NAME 0 a o
SHEET NAME
GENERAL PLUMBING 100 S. Ashley Dr., P: 813 - 323 - 9233
G-000 ICOVERSHEET 10101 P000 PLUMBING LEGENDS AND NOTES • Ste. 100 Lic. #: AA- 0003590
G-010 LIFE SAFETY PLAN 101*1 P101 LEVEL1 UNDERGROUND PLUMBING PLAN • • • Tampa, FL 33602 W: www.bdglip.com
CIVIL P102 LEVEL1 ABOVE GROUNDPLUMBING PLAN • •
C-1 COVER SHEET • P103 ROOF PLUMBING PLAN • •
C-2 GENERAL NOTES 0 • P401 PLUMBING ENLARGED PLANS •
C-3 SOIL EROSION CONTROL PHASE I & DEMO PLAN . • P501 PLUMBING DETAILS • • •
C-4 SITE LAYOUT PLAN • • P601 PLUMBING SCHEDULES • •
C-5 PAVING & GRADING PLAN • • P901 PLUMBING RISER DIAGRAM • • •
C-6 UTILITY PLAN • • • P902 PLUMBING RISER DIAGRAM • •
C-7 CONSTRUCTION DETAILS • • P903 PLUMBING RISER DIAGRAM •
C-8 CONSTRUCTION DETAILS 0 • ELECTRICAL
SURVEY E000 ELECTRICAL LEGENDS AND NOTES • • •
1 I ALTA SURVEY 1 OF 2 • E001 ELECTRICAL RISER DIAGRAM • •
2 1 ALTA SURVEY 2 OF 2 1*1 E002 ELECTRICAL FIRE ALARM LEGEND AND RISER •
LANDSCAPE E101 LEVEL 1 POWER ELECTRICAL PLAN + +
LP -1.01 PLANTING PLAN • • E102 LEVEL 1 LIGHTING ELECTRICAL PLAN • •
LP -5.01 PLANTING DETAILS • • E102,1 LEVEL 1 LIGHTING ELECTRICAL SITE PLAN • •
LP -6.01 PLANTING NOTES & SCHEDULE • • E103 ROOF ELECTRICAL PLAN 9101 •
IRRIGATION E201 LEVEL 1 - FIRE ALARM ELECTRICAL PLAN + 1 W Q
LIi-1.01 IRRIGATION PLAN
EXIST
EXISTING
OS
OVERFLOW SCUPPER
E501
ELECTRICAL DETAILS
FD
FLOOR DRAIN
PF
PRE -FABRICATED
w
>
W
_I
0
Q
�/
W
z
0(�
z
O
t-
c
0
`r""
r~.
N
Q
0
w
0
O
LL
0
z
Q
w
FE
FIRE EXTINGUISHER
PLWD
FIRE -RETARDANT TREATED PLYWOOD
LOCATION MAP
i
DRAWINGS DRAWINGS ISSUED DRAWINGS DRAWINGS ISSUED
3 4 5
e- N N
> > Lh q Ln > > co d Ln
> >
U) GWL' 2' W
U) wLL'
w w' O O O w w O O O
CD C/) �>>>
> > >
c,
�C)w H0wI
L)Ix Ix
W H H tY lY LY W h w CO I Ix
1-- Z Z I_- Z Z Z
w w 'S 'S w w
wan.00o Wa.aoo0
ar- ti I- rte- 00 w
.- 0-
I r :°
o o O a O h N N N N N
r N CV N CV CV r
P N N N 14 N N CCS e3
00 'SHEET# o cSHEET # SHEET NAME 0 a o
SHEET NAME
GENERAL PLUMBING 100 S. Ashley Dr., P: 813 - 323 - 9233
G-000 ICOVERSHEET 10101 P000 PLUMBING LEGENDS AND NOTES • Ste. 100 Lic. #: AA- 0003590
G-010 LIFE SAFETY PLAN 101*1 P101 LEVEL1 UNDERGROUND PLUMBING PLAN • • • Tampa, FL 33602 W: www.bdglip.com
CIVIL P102 LEVEL1 ABOVE GROUNDPLUMBING PLAN • •
C-1 COVER SHEET • P103 ROOF PLUMBING PLAN • •
C-2 GENERAL NOTES 0 • P401 PLUMBING ENLARGED PLANS •
C-3 SOIL EROSION CONTROL PHASE I & DEMO PLAN . • P501 PLUMBING DETAILS • • •
C-4 SITE LAYOUT PLAN • • P601 PLUMBING SCHEDULES • •
C-5 PAVING & GRADING PLAN • • P901 PLUMBING RISER DIAGRAM • • •
C-6 UTILITY PLAN • • • P902 PLUMBING RISER DIAGRAM • •
C-7 CONSTRUCTION DETAILS • • P903 PLUMBING RISER DIAGRAM •
C-8 CONSTRUCTION DETAILS 0 • ELECTRICAL
SURVEY E000 ELECTRICAL LEGENDS AND NOTES • • •
1 I ALTA SURVEY 1 OF 2 • E001 ELECTRICAL RISER DIAGRAM • •
2 1 ALTA SURVEY 2 OF 2 1*1 E002 ELECTRICAL FIRE ALARM LEGEND AND RISER •
LANDSCAPE E101 LEVEL 1 POWER ELECTRICAL PLAN + +
LP -1.01 PLANTING PLAN • • E102 LEVEL 1 LIGHTING ELECTRICAL PLAN • •
LP -5.01 PLANTING DETAILS • • E102,1 LEVEL 1 LIGHTING ELECTRICAL SITE PLAN • •
LP -6.01 PLANTING NOTES & SCHEDULE • • E103 ROOF ELECTRICAL PLAN 9101 •
IRRIGATION E201 LEVEL 1 - FIRE ALARM ELECTRICAL PLAN + 1 W Q
A-510 ROOF DETAILS • • *1 FS -3.1 DIMENSIONED PLUMBING •
LIi-1.01 IRRIGATION PLAN
•
FS -3.2 UNDERGROUND PLUMBING •
•
E501
ELECTRICAL DETAILS
•
A-620 PARTITION TYPES 1010 •
FS -5.0 INTERIOR ELEVATIONS •
U)
D
O
r
V J
w
>
W
_I
0
Q
�/
W
z
0(�
z
O
t-
c
0
`r""
r~.
N
Q
0
w
0
O
LL
0
z
Q
w
S1 GENERAL NOTES &INFORMATION •
LI -5.01 IRRIGATION DETAILS • •
E601 ELECTRICAL SCHEDULES • •
LI -6.01 IRRIGATION NOTES AND SCHEDULE . •
E602 ELECTRICAL KITCHEN EQUIPMEMENT SCHEDULE • +
ARCHITECTURAL
LC SYSTEMS
A-100 FLOOR PLAN • • • •
LC1 COOKLINE HOOD HOOD SCHEDULE •
A-101 DUMPSTER PLANS • • •
LC2 PREP HOOD •
A-120 ROOF PLAN • •
LC3 DISH HOOD FAN SCHEDULE •
A-130 REFLECTED CEILING PLAN • . •
LC4 DETAILS & ELECTRICAL CONNECTIONS •
A-140 PLAN DETAILS • • •
LC5 UL.DUCT •
A-200 EXTERIOR ELEVATIONS • • •
EQUPMENT
A-201 EXTERIOR ELEVATIONS • • •
EQ -1.0
EQUIPMENT PLAN • L •
A-202 EXTERIOR ELEVATIONS • •
EQ -2.0
EQUIPMENT SCHEDULE • L •
A.-300BUILDING SECTIONS • • •
.
EQ 3.0
KITCHEN ITCHEN ELEVATIONS •
A-301 BUILDING SECTIONS • . .
EQ -3.1
KITCHEN ELEVATIONS
A-302 BUILDING SECTIONS • • •
EQ -3.2
KITCHEN ELEVATIONS •
A-310 WALL SECTIONS • •
EQ -3.3
KITCHEN ELEVATIONS •
A-311 WALL SECTIONS • •
EQ -3.4
KITCHEN ELEVATIONS •
A-312 WALL SECTIONS • • •
FIXTURE
A-313 WALL SECTIONS • • •
FS -1.0 KEY TO ELEVATIONS • •
A-314 WALL SECTIONS • • •
FS -2.0 ELECTRICAL ROUGH INS • • •
A-400 ENLARGED RESTROOM PLANS AND ELEVATION • • •
FS -2.1 CONDUIT LAYOUT • •
A410 ENLARGED KITCHEN WALL • • •
FS -2.2 POS WIRING DIAGRAM + •
A-500 WALL DETAIL • + •
FS -2.3 TELEPHONE LAYOUT • •
A-501 ROOF DETAILS • •
FS -3.0 PLUMBING ROUGH INS •
A-510 ROOF DETAILS • • *1 FS -3.1 DIMENSIONED PLUMBING •
41
Architect of Record
Gregg A. Holdsworth, AIA, LEED AP
FL License # AR0017669
ISSUE BY DATE DESCRIPTION
1 RC 08-24-2017 PERMIT COMMENTS
2 RC 9-28-2017 PERMIT COMMENTS 2
3 RC 10-16-2017 OWNER REVISIONS
4 GH 11-21-2017 OWNER REVISIONS
5 SS 01-04.2018 OWNER REVISIONS
PROJECT INFORMATION BLOCK
JOB # 170018
DATE: 07.6-2017
DRAWN BY: RC
CHEOKED BY: SS
SHEET TITLE
COVERSHEET
SHEET NUMBER
A-600 DOOR SCHEDULE AND DETAILS • •
FS -3.2 UNDERGROUND PLUMBING •
a
A-610 WINDOW AND ROOM FINISH SCHEDULE 1010 •
FS -4.0 FINISHES • •
A-620 PARTITION TYPES 1010 •
FS -5.0 INTERIOR ELEVATIONS •
THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY
CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER
"PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG
.ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR
HAKO BEFBDG
THESE PLANS FORECONSTRUCTIO WRITTEN PERMISSION
ARCHITEACTTS.0 E OFWITHOUT
CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE
SUITABILITY AND CONSTRUCTABIUTY OF THE PLANS. THE PLANS SHALL NOT
BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS
WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS,
REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL
OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS
APPROVAL OF BDG ARCHITECTS; OR ANY
WITHOUT THE EXPRESS WRITTEN AP RO
OU H
CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY
REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL
AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG
ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND
COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABIUTY, CLAIMS, OR
DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR
RELATEDTEFERREO THE ANS.AN IMMEDIATELY DGESORCONFUCT5INTHEPLANs
.SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR
TO
PRIOR TO INUING WITH THE WORK.
DI CRREPANCIESORCONFLICTSTOBDGARCHTECTSSPRIORTO FAILURE TOREFER
PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR
DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDUUNG
AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY
SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS.
STRUCTURAL
FS -5.1 IN'T'ERIOR ELEVATIONS • •
S1 GENERAL NOTES &INFORMATION •
FS -5.2 I NTERI(iR EL VA TIONS • •
51.1 WIND LOAD DATA •
FS -5.3 INTERIOR EL NATIONS • •
S2 FOUNDATION PLAN • • • •
FS -6.0 BAR DETAIL:? •
S3 ROOF FRAMING PLAN •
FS -6.1 BAR DETAILS •
S4 FOUNDATION DETAILS • • • •
FS -7.0 BEER SYSTEM' •
S5 ROOF FRAMING DETAILS •
FS -7.1 SODA SYSTEM •
56 FRAMING ELEVATIONS •
FS -8.0 WALL CONSTR. •
S7 FRAMING SECTIONS AND DETAILS •
FS -9.0 MILLWORK DETAILS •
S8 FRAMING SECTIONS AND DETAILS •
FS -9.1 MILLWORK DETAILS •
S9 DUMPSTER ENCLOSURE PLAN • •
FS -10.0 DECOR PLAN •
S10 SATELLITE & DUMPSTER ENCLOSURE DETAILS +
FIRE
MECHANICAL
F000 FIRE PROTECTION LEGENDS AND NOTES •
M000 HVAC LEGENDS AND NOTES •
F001 ARE PROTECTION SITE PLAN •
M101 LEVEL 1 HVAC PLAN • •
F101 LEVEL 1 FIRE PROTECTION PLAN •
M103 ROOF HVAC PLAN •
F501 FIRE PROTECTION DETAILS •
SEAL
M401 HVAC DUCTWORK SECTIONS •
SIGNAGE
M501 HVAC DETAILS •
N-1 SIGN DRAWINGS •
M601 HVAC SCHEDULES •
N-2 SIGN DRAWINGS •
N-3 SIGN DRAWINGS •
N-4 SIGN DRAWINGS •
41
Architect of Record
Gregg A. Holdsworth, AIA, LEED AP
FL License # AR0017669
ISSUE BY DATE DESCRIPTION
1 RC 08-24-2017 PERMIT COMMENTS
2 RC 9-28-2017 PERMIT COMMENTS 2
3 RC 10-16-2017 OWNER REVISIONS
4 GH 11-21-2017 OWNER REVISIONS
5 SS 01-04.2018 OWNER REVISIONS
PROJECT INFORMATION BLOCK
JOB # 170018
DATE: 07.6-2017
DRAWN BY: RC
CHEOKED BY: SS
SHEET TITLE
COVERSHEET
SHEET NUMBER
OUTDOOR TRANSFER SWITCH, SWITCHBOARDS AND
PANEL'C' PROVIDED BY W.R. CONTROLS AT
1-800-417-7543
69,532 AFC
UTILITY PAD
MTD TRANSFORMER
120/208V.30
NOTE:
COMPLY WITH LOCAL UTILITY
CO. METER & C.T. ARRANGEMENT
PRIOR TO INSTALLATION.
FURNISH AND INSTALL AS
REQUIRED BY LOCAL UTILITY
COMPANY.
0
METER
FURNISHED AND
INSTALLED BY E.C.
2
A
O ATS
O
4
NEW
SWITCHBOARD
'MDP'
120/208V/30/4W
1000A MLO
/ * D
PANEL "B"
225A MLO
120/208V.30
NEMA -1
D 44830 AFC
65K AIC
BYPASS
* 120/208V.30
NEMA -1
D 39844 AFC
PANEL "E" 65K AIC 5 KVA
49,995 AFC D 225A MLO UPS o-
120/208V.30 PANEL "POS" '
PANEL "A"
B
PANEL "S"
225A MLO
225A MLO
120/208V.30
120/208V.30
NEMA -1
m
(NEMA -1
44830 AFC
Q
44830 AFC
65K AIC
*
65K AIC
zu-
HIG"PDM
fy.
100A MLO
0
G
* HIGHEST BREAKER IN SWITCHGEAR SHALL NOT BE GREATER THAN A HEIGHT OF 6-6"AFF.
r
of
6'-0„ v
MI IN, I
GROUNDING ELECTRODE SYSTEM CONSISTING OF (2) 5/8" X 10' COPPER CLAD
GROUND RODS, BOND TO BUILDING STEEL, BOND TO CONCRETE ENCASED
ELECTRODE ( ELECTRODE SHALL BE AT LEAST 1/2" AND ENCASED WITHIN AT
LEAST 2" OF CONCRETE) AND COLD WATER PIPE.
ICI
E
FURNISHED AND
INSTALLED BY E.C.
PANEL "C"
225A MLO
120/208V.30
NEMA -1
33460 AFC
65K AIC
PANEL "D"
100A MLO
120/208V.30
NEMA -3R
MARLIN
DIMMING
1 OK AIC
Riser Diagram
120/208V. 30
YED D WING OTES
1. 100% RATED, 65KAIC 1000/3P/NEMA 3R SERVICE RATED TRANSFER
SWITCH WITH 1000A BREAKER PROTECTION, ON NORMAL AND
EMERGENCY SIDE. (FURNISHED BY OWNER AND INSTALLED BY E.C.).
TRANSFER SWITCH SHALL BE 3 -POLES. GENERATOR CONNECTED SHALL
NOT BE CONFIGURED AS SEPARATELY DERIVED SOURCE
2. CT METER CABINET AND 1" CONDUIT BY E.C. METER, CTs AND
CONNECTIONS BY UTILITY COMPANY.
VCIVGrVAL NW 1 G;0
1. TEXAS ROADHOUSE TO SUPPLY THE FOLLOWING ELECTRICAL
DISTRIBUTION EQUIPMENT. EC TO SUPPLY ALL LABOR TO UNLOAD AND
INSTALL DISTRIBUTION EQUIPMENT:
A) SWITCHBOARD MDP WITH FACTORY INSTALLED PANELBOARDS
MDP, A, B, E, S, POS & IG.
B) PANELBOARDS C AND D WILL BE SUPPLIED AS LOOSE
COMPONENTS: BACK BOX, INTERIOR & TRIM,
C) FACTORY INSTALLED TIME CLOCK. CONNECT TO E-26.
D) MAIN EXTERIOR 1000 AMP DISCONNECT SWITCH.
E) FACTORY INSTALLED TVSS. CONNECT TO IG- 14/16/18
2. EC TO CHECK AD TIGHTEN ALL ELECTRICAL CONNECTIONS BEFORE
ENERGIZING.
3. ALL CABLING BETWEEN THE MDP MAIN BREAKERS AND THE INDIVDUALL
PANELBOARDS IN PANEL WALL IS FACTORY SUPPLIED. EC IS
RESPONSIBLE FOR THE FIELD TERMINATION OF EACH CABLE.
4. ALL WIRING BETWEEN PANELBOARD E, PANELBOARD IG, THE FACTORY
SUPPLIED TIME CLOCKS AND THE FACTORY SUPPLIED LIGHTING
CONTROL SYSTEMIS FACTORY INSTALLED.
5. EC TO SUPPLY AND INSTALL ALL MATERIALS REQUIRED TO ACTIVATE
THE FACTORY INSTALLED 120 VAC SHUNT TRIP DEVICE IN MDP BREAKER
THAT FEEDS PANEL S.
6. SWITCHBOARD WILL SHIP IN(1) VERTICAL SECTION AS SHOWN ON SHEET
E5.
7. ALL CONDUITS SHALL BE 3/" UNLESS NOTED OTHERWISE.
* 120/208V.30
NEMA -1
D 39844 AFC
PANEL "E" 65K AIC 5 KVA
49,995 AFC D 225A MLO UPS o-
120/208V.30 PANEL "POS" '
B
Q
W�
NEMA -1
30A MCB
0
65K AIC 44830 AFC
1 10 BATT
20 V-
65K AIC
EMA-
m
Q
65K AIC
Q
W
w0
cl�
G
* HIGHEST BREAKER IN SWITCHGEAR SHALL NOT BE GREATER THAN A HEIGHT OF 6-6"AFF.
r
of
6'-0„ v
MI IN, I
GROUNDING ELECTRODE SYSTEM CONSISTING OF (2) 5/8" X 10' COPPER CLAD
GROUND RODS, BOND TO BUILDING STEEL, BOND TO CONCRETE ENCASED
ELECTRODE ( ELECTRODE SHALL BE AT LEAST 1/2" AND ENCASED WITHIN AT
LEAST 2" OF CONCRETE) AND COLD WATER PIPE.
ICI
E
FURNISHED AND
INSTALLED BY E.C.
PANEL "C"
225A MLO
120/208V.30
NEMA -1
33460 AFC
65K AIC
PANEL "D"
100A MLO
120/208V.30
NEMA -3R
MARLIN
DIMMING
1 OK AIC
Riser Diagram
120/208V. 30
YED D WING OTES
1. 100% RATED, 65KAIC 1000/3P/NEMA 3R SERVICE RATED TRANSFER
SWITCH WITH 1000A BREAKER PROTECTION, ON NORMAL AND
EMERGENCY SIDE. (FURNISHED BY OWNER AND INSTALLED BY E.C.).
TRANSFER SWITCH SHALL BE 3 -POLES. GENERATOR CONNECTED SHALL
NOT BE CONFIGURED AS SEPARATELY DERIVED SOURCE
2. CT METER CABINET AND 1" CONDUIT BY E.C. METER, CTs AND
CONNECTIONS BY UTILITY COMPANY.
VCIVGrVAL NW 1 G;0
1. TEXAS ROADHOUSE TO SUPPLY THE FOLLOWING ELECTRICAL
DISTRIBUTION EQUIPMENT. EC TO SUPPLY ALL LABOR TO UNLOAD AND
INSTALL DISTRIBUTION EQUIPMENT:
A) SWITCHBOARD MDP WITH FACTORY INSTALLED PANELBOARDS
MDP, A, B, E, S, POS & IG.
B) PANELBOARDS C AND D WILL BE SUPPLIED AS LOOSE
COMPONENTS: BACK BOX, INTERIOR & TRIM,
C) FACTORY INSTALLED TIME CLOCK. CONNECT TO E-26.
D) MAIN EXTERIOR 1000 AMP DISCONNECT SWITCH.
E) FACTORY INSTALLED TVSS. CONNECT TO IG- 14/16/18
2. EC TO CHECK AD TIGHTEN ALL ELECTRICAL CONNECTIONS BEFORE
ENERGIZING.
3. ALL CABLING BETWEEN THE MDP MAIN BREAKERS AND THE INDIVDUALL
PANELBOARDS IN PANEL WALL IS FACTORY SUPPLIED. EC IS
RESPONSIBLE FOR THE FIELD TERMINATION OF EACH CABLE.
4. ALL WIRING BETWEEN PANELBOARD E, PANELBOARD IG, THE FACTORY
SUPPLIED TIME CLOCKS AND THE FACTORY SUPPLIED LIGHTING
CONTROL SYSTEMIS FACTORY INSTALLED.
5. EC TO SUPPLY AND INSTALL ALL MATERIALS REQUIRED TO ACTIVATE
THE FACTORY INSTALLED 120 VAC SHUNT TRIP DEVICE IN MDP BREAKER
THAT FEEDS PANEL S.
6. SWITCHBOARD WILL SHIP IN(1) VERTICAL SECTION AS SHOWN ON SHEET
E5.
7. ALL CONDUITS SHALL BE 3/" UNLESS NOTED OTHERWISE.
THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY
CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER
"PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF: BDG
ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR
USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF'BDG
ARCHITECTS, USE OF THESE PLANS FOR CONSTRUCTION SHALL BE
CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE
SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT
BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS
WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS,
REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL
OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY
CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY
REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL
AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG
ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND
COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR
DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR
RELATED TO THE PLANS, ANY DISCREPANCIES OR CONFLICTS IN THE PLANS
SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR
CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER
DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO
PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR
DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING
AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY
SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS.
Adam T. Powell, PE
PE0073853
r®,,11 Y IT. POjV
I
,
1
STAT ®F
p 0
40
O #7
ELECTRICAL SEAL 1/4/201810:33:12 AM
ISSUE BY DATE DESCRIPTION
3 10-16-2017 OWNER COMMENTS
5 01-04-2018 Revision 5
PROJECT INFORMATION BLOCK
JOB # 170509
DATE: 7-6-2017
DRAWN BY: Author
CHECKED BY: Checker
SHEET TITLE
ELECTRICAL RISER
DIAGRAM
SHEET NUMBER
E001
o
�W
VJ
Q
W�
0
�M
Z
m
Q
Q
W
w0
cl�
0
zu-
fy.
W
U�
0
U)
Z
o
ILL
OZ
u)
W
o
THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY
CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER
"PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF: BDG
ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR
USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF'BDG
ARCHITECTS, USE OF THESE PLANS FOR CONSTRUCTION SHALL BE
CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE
SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT
BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS
WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS,
REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL
OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY
CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY
REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL
AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG
ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND
COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR
DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR
RELATED TO THE PLANS, ANY DISCREPANCIES OR CONFLICTS IN THE PLANS
SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR
CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER
DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO
PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR
DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING
AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY
SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS.
Adam T. Powell, PE
PE0073853
r®,,11 Y IT. POjV
I
,
1
STAT ®F
p 0
40
O #7
ELECTRICAL SEAL 1/4/201810:33:12 AM
ISSUE BY DATE DESCRIPTION
3 10-16-2017 OWNER COMMENTS
5 01-04-2018 Revision 5
PROJECT INFORMATION BLOCK
JOB # 170509
DATE: 7-6-2017
DRAWN BY: Author
CHECKED BY: Checker
SHEET TITLE
ELECTRICAL RISER
DIAGRAM
SHEET NUMBER
E001
20
0.
LEVEL 1 POWER ELECTRICAL PLAN
1/411 = 1'-0"
O
......................
OUTDOOR
WAITING AREA
001
C - 52,54
2.9
2.7
2.3
_O
Power - Sheet Notes
Key
Value
Keynote Text
1
NEON OUTLET SURFACE MOUNTED ABOVE 2x8 LEDGER ORAS NOTED. REFER TO DRAWINGS E101 PRIOR TO
ROUGH -IN.
2
J -BOX WITH MUD RING AND FACE PLATE FOR P.O.S COMMUNICATION CABLE, J -BOX AT OUTLET HEIGHT. PROVIDE
CONDUIT FROM J -BOX LOCATION INDICATED ON E101 RUNS WILL BE UNDERGROUND AND OVERHEAD. PROVIDE
PULL STRINGS IN ALL CONDUITS.
3
CIRCUIT SHALL RUN DEDICATED BACK TOCIRCUIT BREAKER AT PANEL, FOR CIRCUITS WITH MULTIPLE OUTLETS
THE CIRCUIT SHALL BE CONNECTED AT THE CIRCUIT BREAKER. EACH CIRCUIT SHALLHAVE A HOT, NEUTRAL,
ISOLATED GROUND AND GROUND WIRE. AL P.O.S AND TABLE CHECK COMMINICATIONS CABLES TO BE
FURNISHED AND INSTALLED BY OWNER. (2#12,1#12G.,1#121G.,3/4"C.) RECEPTACLES LOCATED IN KITCHEN SHALL
BE CIRCUITED TO GFCI CIRCUIT BREAKERS OR SHALL BE WEATHER -RESISTANT IG-GFCI TYPE RECEPTACLES,
4
WORLD DRYER VERDIDRI MODEL #Q -162A BTM.OF AIR DISPENSER HAND DRYER, 110-120V/l w, 996W.
5
MOUNT HORIZONTALLY IN BAR DIE AS HIGH AS POSSIBLE.
6
RECEPTACLE & CABLE T.V. OUTLET FURNISHED AND INSTALLED BY E.C. CABLE INSTALLED BY OWNER. VERIFY
EXACT LOCATION WITH OWNER PRIOR TO ROUGH -IN.
7
120V CIRCUIT FOR NEON SIGN, COORDINATE EXACT LOCATIONS WITH OWNER PRIOR TO ROUGH -IN.
8
BERKO #FFCH5581FFCH RE/FFCH-TK FAN FORCED RECESSED MOUNTED HEATER, 208V/1 w, 5000W. PROVIDE WALL
THERMOSTAT SET AT 60F.
9
_
QUAD RECEPTACLE FOR PAGER DEVICE AT HOSTESS STAND.
10
1/2" CONDUIT BACK TO TELEPHONE BACKBOARD WITH CABLE (24 GA., 64 4W) FURNISHED AND INSTALLED BY
CONTRACTOR, THE PHONE JACK SHALL BE INSTALLED IN A 4" BOX, WITH A SINGLE -GANG MUD RING.
11
J -BOX FOR STUB UP INTO WALL AND FEED THROUGH PLATFORM.
12
J -BOX FOR SPEAKER WIRE AT LOCATION SHOWN.
13
_
CCN MONITOR IN TO GO AREA.
14
2#12,1#12G.,1 1#121G., 3/4"C.
15
MOUNT TWO RECEPTACLES, ONE AT 18" AND ONE AT 30" AFF, FOR STACKED CONVECTION OVENS.
16
PROVIDE JUNCTION BOX MOUNTED AT 96" ABOVE FINISHED FLOOR INSIDE OF BULKHEAD FOR HANGING HEAT
LAMPS. 120V,1 o, 250W EACH.
17
Q-MARK#FRP236AS FAN FORCED CEILING MOUNTED NEATER, 208V/1o, 3000W. WIRE HEATER THROUGH
CP2004801 FOUR 3 -POLE CONTACTOR PANEL, THEN TO (1) TOGGLE SWITCH TO CONTROL (3) HEATERS. KICATE
TOGGLE SWITCH IN EXPO AREA NEAR FAN SWITCHES; COORDINATE WITH TEXAS ROADHOUSE
REPRESENTATIVE.
18
J -BOX AT 60" A.F.F. WITH 112" CONDUIT TO 6" ABOVE CEILING FOR MICROPHONE.
19
J -BOX FOR CCTV AT 8'-6" A.F.F, STUB CONDUIT ABOVE CEILING.
20
1/2"x 2'x4' PLYWOOD BACKBOARD FOR TELEPHONE EQUIP. (1) DEDICATED OUTLET FOR TELEPHONE EQUIPMENT
AND (2) QUAD OUTLETS FOR SECURITY SYSTEM VENDOR.
21
RECEPTACLE FOR FACP. COORDINATE WITH FA1 SHEET FOR EXACT LOCATION.
22
PROVIDE JUNCTION BOX FOR TELEPHONE CONNECTION.
23
J -BOX FOR DOOR ALARM SYSTEM WITH 1/2" CONCEALED CONDUIT AT 5'-6" A.F.F TO ABOVE DOOR MAGNETIC
HOLDER.
24
J -BOX FOR FLY FAN WITH CONNECTION TO DOOR SWITCH, MOUNT 86" A.F.F.
25
PROVIDE POWER CONNECTION TO PREFABRICATED WATERHEATER RACK LOAD CENTER, AS REQUIRED BY
MANUFACTURER.
26
FAN MOTOR CONTROL CENTER ABOVE ELECTRICAL PANEL, HOLD TIGHT TO CEILING. SEE HOOD DRAWINGS FOR
WIRING DIAGRAMS.
27
OUTLET FOR GLYCOL CHILLER, VERIFY LOCATION WITH OWNER PRIOR TO MOUNTING.
28
FOR UNDERCOUNTER BAR LIGHTING SWITCHED. MOUNT SWITCH UNDER BOX NEXT TO OUTLET.
29
PROVIDE JUNCTION BOX FOR CONNECTION OF DIMMER REMOTE CONTROL PANEL MOUNTED 60" ABOVE
FINISHED FLOOR.
30
ROUTE NEON SIGN OUTLETS THROUGH WALL SWITCH LOCATED ADJACENT TO FAN SWITCH.
31
COORDINATE WITH DOOR ALARM MANUFACTURER'S CUTSHEET FOR WIRING ALARM TO TRANSFORMER TO
PANEL CIRCUIT BREAKER.
32
INSTALL SO PANEL TRIM IS FLUSH WITH SIDING AT THIS AREA. _
33
EXTERIOR SIGN SEE ARCHITECTURAL BLDG. ELEVATIONS. GROUNDING SHALL BE ISOLATED AND DEDICATED
BACK TO ELECTRICAL PANEL, COORDINATE WITH SIGN INSTALLER. _
34
INSTALL IRRIGATION TIMECLOCK IN REAR WALL OF UNILITY ROOM. COORDINATE WITH LANDSCAPE DRAWINGS.
35
J -BOX ABOVE HOOD FOR OIL RECOVERY ALARM.
36
DOOR BELU DOOR BUZZER AND TRANSFORMER. PROVIDED BY ELECTRICAL CONTRACTOR,
37
PROVIDE CLEARANCES FOR ELECTRICAL PANELS PER N.E.C. 110.26. PANEL CIRCUIT BREAKER SHALL BE AN
ACCESSIBLE HEIGHT OF 6'-7" AFF PER NEC 404.8.
38
RECEPTACLE FOR NEON SIGN MOUNTED ON TOP OF TIN ROOF.
39
RECEPTACLE FOR NEON SIGN MOUNTED ON TOP OF HEADER. (78' AFF)
40
CONNECTION FOR EVAPORATOR COIL INSIDE WALK-IN. EXTEND INTERWIRING TO ROOF COMPRESSOR PER
MANUFACTURER'S DRAWINGS.
41
PROVIDE CONNECTION FOR HEAT TAPE AT CONDENSATE LINE. COORDINATE LOCATION WITH G.C.
42
PROVIDE CIRCUIT FOR CONDENSATE DRAIN LINE HEATER AS REQUIRED.
43
120V 1 o CONNECTIONS FOR LIGHTS, DOOR HEATERS AND DEFROST TIMERS ALL WALK-IN LIGHTS AND DOOR
HEATER CONNECTIONS AND INSTALLATIONS ARE THE RESPONSIBLITY OF THE ELECTRICAL CONTRACTOR.
LIGHTING CONDUIT TO BE RUN ABOVE WALK-IN BOX AND ALL PENETRATIONS THROUGHLY SEALED. LIGHT
FIXTURES FURNISHED UNINSTALLED BY THE WALK-IN SUPPLIER, INSTALLATION AND WIRING BY THE ELECTRICAL
CONTRACTOR. SEE SHEET EQ4 FOR LOCATION OF DEFROST TIMERS.
44
E.C. SHALL CONNECT "FLOW AND TAMPER" SWITCHES ON BOTH O.S. & Y VALVES OF THE BACK FLOW
PREVENTION DEVICE ON THE FIRE SPRINKER RISER, SWITCHES SHALL CONNECT TO THE BUILDING SECURITY
SYSTEM. E.C. SHALL COORDINATE WITH FIRE SPRINKLER AND SECURITY SYSTEM VENDOR PRIOR TO
INSTALLATION.
45
J -BOX FOR MICROPHONE.
46
J -BOX FOR CATS & TEL JACK IN MILLWORK.
47
(2) 2" C FOR TELEPHONE AND CABLE TV.
NOTE: ALL CONDUIT TO BE RUN OUTSIDE OF WALK-IN AND PENETRATIONS TO BE THOROUGHLY CAULKED WITH FOOD GRADE
SILICONE SEALER. RACEWAYS THAT PENETRATE COOLERS THAT ARE KNOWN TO BE SUBJECT TO DIFFERENT TEMPERATURES
AND CONDENSATION SHALL BE FILLED INSIDE THE RACEWAY WHERE IT ENTERS THE COOLER WITH AN APPROVED MATERIAL
TO PREVENT THE CIRCULATION OF WARM AIR TO THE COOLER SECTION. (SEE 300.7 OF NFPA 70).
GENERAL NOTES
1. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT SHOWN ON
THIS DRAWING.
2. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATION AND REQUIREMENTS OF ALL PLUMBING EQUIPMENT SHOWN ON
THIS DRAWING.
EC, TO FURNISH & INSTALL CONDUIT(S) & J -BOXES) FOR T -STAT OF EACH RTU, SEE SHEET M103 FOR LOCATION &
COORDINATE W/ M.C.
NOTE:
E.C. TO CONSULT HOOD MANUFACTURER'S WIRING DIAGRAMS AND CONTROL CABINET LAYOUT FOR ALL EXHAUST HOOD FAN
REQUIREMENTS, FOR DRAWINGS CONTACT OWNER OR LC SYSTEMS @ 1-614-235-9430.
GENERAL SHEET NOTES
1. REFER TO PANEL SCHEDULES ON E601 FOR ALL CONDUCTOR SIZES
3. PROVIDE NO. 10 WIRE IN LIEU OF N0, 12 WIRE FOR ANY BRANCH CIRCUIT EXCESS OF 100 FEET (120V) OF CIRCUIT LENGTH TO
FARTHEST DEVICE TO PREVENT EXCESSIVE VOLTAGE DROP, PROVIDE NO.8 WIRE IN LIEU OF NO. 10 WIRE FOR ANY BRANCH
CIRCUIT IN EXCESS OF 160 FEET (120V) OF CIRCUIT LENGTH TO FARTHEST DEVICE TO PREVENT EXCESSIVE VOLTAGE DROP.
i
205 N: ARMENIA AVE; #102
TAMPA; FL 33609
TEL, (813) 995-0300
FAX (813)995-0400
FLORIDA ENGINEERING BUSINESS #002784
COPYRIGHT 2016- EMERALD ENGINEERING
W
0
W
o
D
M
=
O<
Q
coo
Q
zLijU_
OC
co
r� //'��
VJ
LIJ
z
W
0
�z
O
U)
W
0
C_
THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY
CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS )HEREINAFTER
"PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG
ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR
USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF BDG
ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE
CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE
SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT
BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS
WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS,
REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL
OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS: OR ANY
CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY
REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL
AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG
ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND
COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR
DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR
RELATED TO THE PLANS. ANY DISCREPANCIES OR CONFLICTS IN THE PLANS
SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR
CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER
DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO
PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR
DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING
AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY
SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS.
Adam T. Powell, PE
PE007385 ®®\®11111111/
T. P01V
61-4-zol'� .:
1 �
v \\ TE 0
NAI.
1111?`®
ELECTRICAL SEAL 1/4/201810:33:13 AM
ISSUE BY DATE DESCRIPTION
3 10-16-2017 OWNER COMMENTS
5 01-04-2018 Revision 5
PROJECT INFORMATION BLOCK
JOB # 170509
DATE: 7-6.2017
DRAWN BY: Author
CHECKED BY: Checker
SHEET TITLE
LEVEL1 - POWER
ELECTRICAL PLAN
SHEET NUMBER
E1 01
C
C
PANELBOARD: D
LOCATION: VOLTAGE: 208Y/120 V. 3 o 4 W.
MOUNTING: RECESSED... A.I.C. RATING: 10,000 AMPS SYMMETRICAL
MAIN DEVICE: 100 A MLO SPECIAL:
BUS AMPS: 100 AMPS
LOAD DESCRIPTION
BKR P
NOTES
CKT
PANELBOARD: A
NOTES
P
BKR
LOAD DESCRIPTION
TRACK LIGHTS @ BAR...
20 A 1
2 A 1
1
PANELBOARD: B
-,; r_ r w
2
1
-- --
-
20 A
LOCATION:
TRACK LIGHTS @ ENTRY
20 A 1
1
VOLTAGE: 208Y/120 V. 3 o 4 W.
0.1
0.0 " „;" :
4
5
7
LOCATION:
20 A
DINING LIGHTS (PENDANT)_
TRACK LIGHTS @ BAR...
20 A 1
VOLTAGE: 208Y/120 V. 3 o 4 W.
5
0.0 0.0
0.1 0.1
6
MOUNTING: SURFACE...
1
20 A
DINING LIGHTS (PENDANT)
A.I.C. RATING: 65,000 AMPS SYMMETRICAL
20 A 1
SPARE
7
MOUNTING: SURFACE...
�
0.0
8
10
_13
15
A.I.C. RATING: 65,000 AMPS SYMMETRICAL
20 A
20 A
TRACK LIGHTS @ ENTRY
ENTRY LIGHTS
TRACK LIGHTS 20A 1 9 0.1
MAIN DEVICE: 225 A MLO
20 A 1
SPECIAL:
11
20 A
0 1 0 0
12
KITCHEN LIGHTS
SITE LIGHTING_ -
MAIN DEVICE: 225
A MLO
TRACK LIGHTS @ WAITING
DINING LIGHTS
20 A 1
SPECIAL:
13
0.1 0.1 ,.;.
20 A
14
20A 1
1
BUS AMPS: 225 AMPS
DINING LIGHTS
BAR LIGHTS
20 A 1
-20 A
150.1
20 A
0.1
16
BUS AMPS: 225
AMPS
20 A
_
TRACK LIGHTS @DINING
DINING LIGHTS
20 A 1
NEON OUTLET
17
SPARE
0.1 0.1
18
25
-1
1 20 A
TRACK LIGHTS @ DINING
EMERGENCY/EXIT...
20 A 1
L 1,2
19
0.5 0.0 _: ',
•' M„ung
20
P R 0 0 1.5 ,
1
1 20 A
I DO NOT USE
DINING / WAITING FANS
21 A 10 A
NEON OUTLETS _
TOTAL LOAD:
TOTAL AMPS:
1 kVA 0 kVA 0 kVA
8A 3A 4A
29
.. 0.1
0.5.
LOAD DESCRIPTION
BKR
P
NOTES
CKT
PHASE PHASE B kPHASE
VA
A kVA C kVA
CKT
NOTES
P
BKR
LOAD DESCRIPTION
LOAD DESCRIPTION
BKR
P
_
NOTES
CKT
PHASE
PHASE B
A kVA
kPHASEVA
C kVA
CKT
NOTES P
BKR
LOAD DESCRIPTION
20 A
NEON OUTLET
WALK-IN MEAT COOLER
O ROOF
COMPRESSOR ( N )`''
20 A
3
22
1 1.6 0 9KF .. 2
; „ , .,, „
3 1.6 0 9 4
1794 VA_
2
20A
WALK IN FREEZER COIL
GP OUTLETS AT BAR
20 A
1
1
1
0.7 0,9
„'
2
2 1
20 A
BAR UC REFRIGIRATOR
SPARE 20 A 1 3 0 0 0.5 4
1_ 20A
SECURITY SYSTEM
5'; 1.6 1.8 6
7 1.6 1.8 ., 8
9 1 6 1 8 10
1
3
30 A
ICE MACHINE REMOTE
CONDENSER (ON ROOF)
SODA DISPENSER 20 A 1 2 5 1.5 0 8 6
ICE TEA BREWER 20 A l 2 70 6 0.5 8
TELEPHONE BACKBOARD 20 A 1 9 0.2 0.4 10
1 20 A
SECURITY SYSTEM
-
WALK-IN COOLER
COMPRESSOR (ON ROOF)
20 A
3
20 A
1 20 A
OFFICE RECEPTACLE
1_ 20A
_
OFFICE OUTLETS
11440
1.6 1.2 12
1
1
20 A
WALK-IN LIGHTS AND DOO...
MUSIC SYSTEM 20 A 1 11
_ ,,. �' 1 0 1.5 12
1 20 A
LIQUOR DISPLAY
MEAT COOLER...
20 A
1
12800 VA
1 13 0.5 0.4 tea: •,,,; ,. , 14
LOAD: 28518 VA --
1
20 A
UC REF. _�
GLASS WASHER 20 A 1 13 0.9 0.8 14
2 1 20 A
BOTTLE COOLER
_
TV OUTLETS
20 A
1
_CONNECTED
ESTIMATED DEMAND: 30105 VA
15
1.1 1.8 „';,
16
1
20A
EF -7 / 8 ON ROOF
FROZEN COCKTAIL MACH...
20 A
1
2
15
°< ;• 1.8
0.7
16
2 1
20 A
MUG FROSTIER
_
6492 VA
1.7 1.8
PAGER DEVICE
20 A
1
KTCH
17.;; 1.1 0.2 18
2
1
20 A
CONVENIENCE
HAND DRYER -...
BAR UC REFRIGIRATOR
20A
20A
1
1
2
17
19
s; ,• 1.0 0.5
0.9 1.8
18
- -
20
1
20 A
WALK-IN COOLER COIL
SPARE
20A
1
37
19 0.0 0.4 "-, ',: 1 20
38
1
20 A
CONVENIENCE OUTLET
-- -- -
2 25 A
CHEESE MELTER
GRINDER @MEAT COOLER20
A
1
2
21 „ ..,._."' ";, 1.5 1.5 22
2
1
20 A
CARBONATOR
0.5 ..,
HANGING HEAT LAMPS 20A 1 21tttt1
- 1.8 = „', 22
WORK TABLE...
20A
1
30 A
23 - .....,..: 0.5 0.0 24
25 0.2 U.6 gun • ,,,,,,, , „ " ", '" 26
3
1
20 A
SPARE-�-
EXTERIOR OUTLETS 20 A 1 23 ,,,w,•,-•,, 0.5 0.5 24
1 20 A
OFFICE OUTLETS
CD PLAYER RECEPTACLE
20 A
1
20 A
1
1
20 A
ICE TEA BREWER
CONVENIENCE OUTLETS
20A
1
25
2.0 0.2
SPARE
26
2 1
20 A
GP OUTLETS @DISH...
0.0 1.5 , � �'
27
1 5 1 5
28
2
MUG FROSTER
20 A
1
2
27
0.7
1.5 r..
28
WALK-IN FREEZER
COMPRESSOR (ON ROOF)
20 A
3
2
20A
1
20 A
UNDER BAR LIGHT
-
2 1
20 A
COFEE MAKER
29 1.5 1.5 30
50
1
20 A
HEAT TAPE
CONVENIENCE OUTLETS 2 A 1 29 n,
q 0 9 1.1 30
1 20 A
TV OUTLETS
31 1.5 1.8 , r. •, 32
1
3
-__
30 A
ICE MACHINE REMOTE
CONDENSER (ON ROOF)
_ _
HAND DRYER -... 20 A 1 31 1.0 0.0r 32
HAND DRYER -... 20 A 1 33 1.0 1.1 „'' ,• ':" 34
1 20 A
SPARE
BEER COOLER COIL
-
BEER GLYCOL
20A
20 A
1
1
2
33 0.5 1.8 .,: 34
35 W a ._r ..... `<.... 1.5 1.8 36
-
1 20 A
---
TV OUTLETS
-
FREEZER/COOLER COMBO 20A 1 2 35 , '', `. 1.2 1.2 36
3 20 A
MIXER
BEER COOLER
COMPRESSOR (ON ROOF)
20A
3
20 A
37
39
0.9 0.4 , • �,
0.9 0.9
38
40
2
1
1 1
20 A
1 20 A
CONVENIENCE OUTLET
ICE MACHINE
SODA DISPENSER
20 A
1
2
37
1.! 1 2', ,, , '
""•
38
CHILLED BEVERAGE... 20 A 1 2 39 0.4 1.2 40
41 -, 0.9 0.9 42 2 1 20 A ICE MACHINE
CABLE TV OUTLETS 20 A 1 41 s•, 1.0 0.1 42 1
_
20 A
IRRIGATION TIME CLOCK
LOAD CLASSIFICATION
TOTAL LOAD:
12 kVA 18 kVA 16 kVA
DEMAND ESTIMATED
PANEL
TOTALS
Lighting
TOTAL LOAD:
13 kVA 12 kVA_ 13 kVA
125.00% 1925 VA
Other
TOTAL AMPS:
102 A 158 A 136 A
100.00% 34486 VA
_ _
CONNECTED LOAD: 61094 VA
_
RCPT
TOTAL AMPS:
110A 97 A
_
107 A
ESTIMATED DEMAND: 56197 VA
SPEC
1704 VA
LOAD CLASSIFICATION CONNECTED DEMAND
ESTIMATED PANEL TOTALS
LOAD CLASSIFICATION
CONNECTED CURRENT: 170 A
CONNECTED
DEMAND_
14991 VA
_
ESTIMATED
65.00% 9744 VA
PANEL TOTALS --�
O
Other
32919 VA
100.00%
32919 VA
_
1. GF61 BREAKE
Other
5
7610 VA
100.00%
7610 VA
2.(2) #10 CU, (1) #10 CU EG.
-
_ _ _
RCPT
11801
VA
92.37%
10901 VA
3. (3) #10 CU , (1) #10 CU EG.
CONNECTED
LOAD:
46414 VA
RCPT
14098 VA
85.47%
_
- 12049 VA
CONNECTED
LOAD: 37376 VA
KTCH 2220 VA 65.00%
1443 VA ESTIMATED DEMAND:
44790 VA
-Y
SPEC
3598 VA
100.00%
3598 VA
ESTIMATED DEMAND: 31102 VA
_
_
CONNECTED CURRENT:
129 A
KTCH
12077 VA
65.00%
VA
CONNECTED CURRENT: 104 A
A_TEST.
DEMAND CURRENT:
124 A
_7.8_50
EST. DEMAND CURRENT: 86 A
N
5 _
NOT
1. (3 #10 CU , ( ) #10 CU E
. IN 3/4"C
1. (2) #10 CU, (1) #10 CU EG. IN 3/4"
C
5
2. GFCI BREAKER
2. GFCI BREAKER
PANELBOARD: D
LOCATION: VOLTAGE: 208Y/120 V. 3 o 4 W.
MOUNTING: RECESSED... A.I.C. RATING: 10,000 AMPS SYMMETRICAL
MAIN DEVICE: 100 A MLO SPECIAL:
BUS AMPS: 100 AMPS
LOAD DESCRIPTION
BKR P
NOTES
CKT
AAA PHASE B kVA C E CKT
NOTES
P
BKR
LOAD DESCRIPTION
TRACK LIGHTS @ BAR...
20 A 1
2 A 1
1
0.1 0.1 �,kVA
,
-,; r_ r w
2
1
-- --
1
20 A
TRACK LIGHTS @...
TRACK LIGHTS @ ENTRY
20 A 1
1
3
0.1
0.0 " „;" :
4
5
7
1
20 A
DINING LIGHTS (PENDANT)_
TRACK LIGHTS @ BAR...
20 A 1
5
5
0.0 0.0
0.1 0.1
6
1
1
20 A
DINING LIGHTS (PENDANT)
TRACK LIGHTS
20 A 1
SPARE
7
0.1 0.0
�
0.0
8
10
_13
15
1
1
20 A
20 A
TRACK LIGHTS @ ENTRY
ENTRY LIGHTS
TRACK LIGHTS 20A 1 9 0.1
DINING LIGHTS
20 A 1
SPARE
11
20 A
0 1 0 0
12
KITCHEN LIGHTS
SITE LIGHTING_ -
1
20 A
TRACK LIGHTS @ WAITING
DINING LIGHTS
20 A 1
_ 1
-- --
13
0.1 0.1 ,.;.
20 A
14
20A 1
1
20 A
DINING LIGHTS
BAR LIGHTS
20 A 1
-20 A
150.1
20 A
0.1
16
15
1
20 A
_
TRACK LIGHTS @DINING
DINING LIGHTS
20 A 1
NEON OUTLET
17
SPARE
0.1 0.1
18
25
-1
1 20 A
TRACK LIGHTS @ DINING
EMERGENCY/EXIT...
20 A 1
L 1,2
19
0.5 0.0 _: ',
•' M„ung
20
P R 0 0 1.5 ,
1
1 20 A
I DO NOT USE
DINING / WAITING FANS
21 A 10 A
NEON OUTLETS _
TOTAL LOAD:
TOTAL AMPS:
1 kVA 0 kVA 0 kVA
8A 3A 4A
29
.. 0.1
0.5.
30
_
LOAD CLASSIFICATION
_
RESTROOM LIGHTS
CONNECTED
TOWER LIGHTS
DEMAND ESTIMATED
20 A
31
PANEL TOTALS
Lighting --
_
_
222 VA
_
125.00% 278 VA
20 A 1
_
33
-�
34
Other
20 A
NEON OUTLET
447 VA
VISUAL PAGING
100.00% 447 VA
22
CONNECTED LOAD:
1794 VA_
LITES__
1
3
20 A
30 A
1138 VA
VISUAL PAGING 20A 1 _
VISUAL PAGING 20A 1
125.00% 1423 VA
1
ESTIMATED DEMAND:
2132 VA
24
_
TOTAL LOAD:
_TOTAL AMPS:
9 kVA 8 kVA 12 kVA
72A 65A 105 A
1
20 A
HAND DRYER - RESTROOMS
_ _
CONNECTED CURRENT:
5 A
CONNECTED
DEMAND
ESTIMATED
PANEL TOTALS
EST. DEMAND CURRENT:
6 A
NOTES:
1. PROVIDE HANDLE LOCK -ON DEVICE.
2. NON -DIMMED & NON -SWITCHED CIRCUIT FOR EM ERGENCY LIGHTING,
PANELBOARD: S
LOCATION: VOLTAGE: 208Y/120 V. 3 o 4 W.
MOUNTING: SURFACE... A.I.C. RATING: 65,000 AMPS SYMMETRICAL
MAIN DEVICE: 225 A MLO SPECIAL:
BUS AMPS: 225 AMPS
1. GFCI' BREAKER:
2. (3) #10 CU , (1) #10 CU EG. IN 3/4" C
3. (3) #8 CU , (1) #10 CU EG. IN 3/4" C
4. (2) #8 CU , (1) #10 CU EG. IN 3/4" C
PANELBOARD: E
LOCATION: VOLTAGE': 208Y/120 V. 3 o 4 W.
MOUNTING: SURFACE.., A.I.C. RATING: 65,000 AMPS SYMMETRICAL
MAIN DEVICE: 225 A MLO SPECIAL:
BUS AMPS: 225 AMPS
2.COORDINATE INSTALLATION REQUIREMENTS WITH SIGN SUPPLEIER.
&THESE CIRCUITS ARE ROUTED THROUGH SMART BREAKER, ZONE A, TC2-CB
4.PROVIDE HANDEL LOCK -ON DEVICE.
PANELIBOARrL): POS
LOCATION: VOLTAGE: 120V1240 V. 1 o 3 W.
MOUNTING: SURFACE NE... A.I.C. RATING: 65,000 AMPS SYMMETRICAL
MAIN DEVICE: 30 A MAIN CB SPECIAL:
BUS AMPS: 100 AMPS
LOAD DESCRIPTION
LOAD DESCRIPTION
BKR P
NOTES
CKT
A VA PHASE B kVA C" VA CKT
NOTES P
BKR
LOAD DESCRIPTION
P BKR LOAD DESCRIPTION
ER LI
2 A 1
1
1
3
10.210.1 v„ u,
m 0.3 0 0
21
4
1
-- --
20 A
DISPLAY AND PREP LIGHTS
FACP 20 1 4
--
SPACE
1
TOWER CTS A
20fV
1
1
5
7
0.2 2.51
0.2 2.5,....4..-'_
6
8
4 2
20 A
MECHANICAL ROOM HEATEI
5
TO O A 1 1_
0.0 0.0
EXTERIOR LIGHTS
20 A 1
1
_ 9
=' 0.1 0.0
10
1
_
20 A
SPARE
„
EXTERIOR BLDG. LI
LIGHTS
EXTERIOR LIGHTS
0
2 A 1
20 A 1
1
1
_13
15
0.9 0.5
0.1 0.0
0.2 1.1 µ.'
12
14
16
1
1
1
20 A
PREP AREA & OFFICE...
20 A
SPARE
NIGHT LIGHT /... 20 A 1 5
20 A
_-
ROOF OUTLET
20 A
KITCHEN LIGHTS
SITE LIGHTING_ -
20 A _ 1
20 A 1
1 _
17
19
0.2 0.7
0.8 0.0
18
20
_ 1
-- --
20 A
--
NEON OUTLETS
SPACE
20 A
SPARE
20A 1
13
21
.,w, 0.0 0.4
22
_
2 1
-20 A
SIGN NEON OUTLETS
20 A
SPARE
20A 1
15
23
"��� , 0.0 0.7
24
1
20 A
NEON OUTLET
20 A
SPARE
20 A 1
17
25
0.0 0.2
26
_�-
1
20 A
--
JUKE BOX
HOTWELL -SINGLE
SPARE
20A 1
_
27
P R 0 0 1.5 ,
28
1
20 A
DINING / WAITING FANS
21 A 10 A
NEON OUTLETS _
20 A 1
UNDERCOUNTER HEAT...
29
.. 0.1
0.5.
30
_ 1
20 A
_
RESTROOM LIGHTS
1
TOWER LIGHTS
20 A 1
20 A
31
0.3 0.5
32
1
20 A_
DISH ROOM &PREP LIGHTS
_
TV OUTLET
20 A 1
_
33
0.9 0.7
34
1
20 A
NEON OUTLET
1
VISUAL PAGING
20A 1
22
35
37
39
41
0.511.6
0.5 3.238
0 5 3.2 a
e. ...- 1.1 3.2
36
40
42
1
3
20 A
30 A
TIN CEILING OUTLETS
FAN CONTROL CENTER LC
SYSTEM
VISUAL PAGING 20A 1 _
VISUAL PAGING 20A 1
_
WATER SOFTENER 20 A 1
1
23
0.7 1.0
24
_
TOTAL LOAD:
_TOTAL AMPS:
9 kVA 8 kVA 12 kVA
72A 65A 105 A
1
20 A
HAND DRYER - RESTROOMS
_ _
20A
LOAD CLASSIFICATION_
CONNECTED
DEMAND
ESTIMATED
PANEL TOTALS
20 A
Lighting
MECH, ROOM GENERAL...
20 A
601 VA
_125.00%
751 VA
28
1
1
20 A
Other _
VESTIBULE HEATER
25 A
12800 VA
2
_100.00%
12800 VA
30
LOAD: 28518 VA --
RCPT
20 A
U/C REFRIG
9452 VA
100.00_%
9452 VA
___
_CONNECTED
ESTIMATED DEMAND: 30105 VA
LITES
843 VA
125.00%
1054 VA
CONNECTED CURRENT:
79 A
2
SPEC
CHEESE MELTER
HOTWELL-SINGLE
5212 VA
1
124.5.5%
_
6492 VA
1.7 1.8
EST._ DEMAND CURRENT:
84 A
KTCH
126 VA-
65.00%
82 VA
1
1
35
s 2.0 0.6
36
�1THTI!SCIRCUTS�ARE OUT �THRO`UH MARTREAKER, ONE A, TC3-CB.'V5
1
20 A
2.COORDINATE INSTALLATION REQUIREMENTS WITH SIGN SUPPLEIER.
&THESE CIRCUITS ARE ROUTED THROUGH SMART BREAKER, ZONE A, TC2-CB
4.PROVIDE HANDEL LOCK -ON DEVICE.
PANELIBOARrL): POS
LOCATION: VOLTAGE: 120V1240 V. 1 o 3 W.
MOUNTING: SURFACE NE... A.I.C. RATING: 65,000 AMPS SYMMETRICAL
MAIN DEVICE: 30 A MAIN CB SPECIAL:
BUS AMPS: 100 AMPS
LOAD DESCRIPTION
BKR
P
NOTES
CKT
A B
C
CKT
NOTES
P BKR LOAD DESCRIPTION
HOSTESS STAND
_
20 A
1
1
1
1
0.4 0.4 , .
0.9 0 7
- 0.9 1 7
2
1
1 20 A P.O.S. TERMINAL, PRINTER1
OFFICE COMPUTER
_
20 A
1
1
3
0.4
0.0
4
_
1 20 A SPARE-
P.O.S. PRINTERS
20 A
1
-1
5
5
0.0 0.0
_
6
.-.
1
.
1 20A P.O.S. TERMINAL, PRINTER1
SPARE
20 A
REACH -IN REFRIGERATOR
20 A
7
0.0 0.0
„
8
8
_. -
1 20 A SPARE
SPARE
--
20 A
1
PLATE CHILLER
9
0 0
0.0
10
9
1 20 A SPARE
SPARE _
20 A
1
44303 VA
11
LOAD CLASSIFICATION_
0.0 0.0
12
1-
1 20 A P.O.S. TERMINAL, PRINTER1
SPARE_ _
20 A
1
2
13
0.0 0.0
20A
14
KTCH _
1 20 A SPARE
SPARE _
20 A
1
., .......,
15
m 0.0
�'
0.4
16
_
1
_
1 20 A P.O.S. PRINTERS
SPARE
20 A
1
-
17
, ."
-. 0.0 0.0.
18
_
1 20 A SPARE
20 A
HOTWELL -SINGLE
_
TOTAL LOAD:
2 kVA 1 kVA 0 kVA
1
- f
0.9 0.7
16
1
TOTAL AMPS:
21 A 10 A
0 A-
LETTUCE CRISPER
UNDERCOUNTER HEAT...
LOAD CLASSIFICATION
-
1
CONNECTED_
DEMAND
^' "m, , W.�e " .., 1.1 0.7
_
ESTIMATED
1
_
- PANEL TOTALS
RCPT
20 A
REFRIG. DISPLAY
_
3480 VA
100.00%
1
3480 VA
19
_
-
_
BREAD WARMER
20A
- CONNECTED LOAD: 3480 VA_
1
21
0.9 1,5
22
2
_
25A
ESTIMATED DEMAND: 3480 VA
_
20 A
1
1
23
0.7 1.0
24
--
CONNECTED CURRENT: 17 A
1
20 A
HAND DRYER - RESTROOMS
SPARE
20A
1
25
EST. DEMAND CURRENT: 17 A
NOTES:
1. CONNECT TO ISOLATED GROUND BAR.
PANELBOARD: C
LOCATION: VOLTAGE: 208Y/120 V. 3 o 4 W.
MOUNTING: RECESSED... A.I.C. RATING: 65,000 AMPS SYMMETRICAL
MAIN DEVICE: 225 A MLO SPECIAL:
BUS AMPS: 225 AMPS
LOAD DESCRIPTION
BKR
P
NOTES
CKT
A B C
CKT
NOTES
P
BKR
LOAD DESCRIPTION
HOTWELL-SINGLE
20 A
1
1
1
1
1
3
0.9 0 7
- 0.9 1 7
2
4
1
_
37.8 kVA RTU -4 -�
1
20 A
POTATO WARMER -
UC REFRIG.
20 A
1
1
20 A
POTATO WARMER
MICROWAVE
20A
1
1
5
�`' 2 0 0 4
6
1
1.0 0.0 ;,',
1
20 A
MEAT COOLER OUTLETS
REACH -IN REFRIGERATOR
20 A
1
1
7
0.9 0.9 ";"'
8
1
30 A
20 A
1
20 A
PLATE CHILLER
FUTURE LARGE
14
16
18
3 15 A TVSS
-
FRONT ENTRANCE BLDG....
9
0.0 1.2
10
TOTAL_ LOAD:
TOTAL AMPS:
3 kVA 1 2 kVA 0 kVA
1 31 A I 19A_-, 3 A
44303 VA
LOAD CLASSIFICATION_
MICROWAVE OVEN11
30 A
2
2
0.0 1.2
12
2
112.52%
2
20A
TRIPLE HOT WELL
KTCH _
50289 VA
RCPT
32688 VA
EST. DEMAND LOAD:
., .......,
_
100.00% 3480 VA
CONNECTED LOAD: 5888 VA
CONN. CURRENT:
1111 A
FLY FAN @ REAR DOOR
20 A
1
1
13
0.7 1.7 , ._s • "'
14
1
1
20 A
HOTWELL -SINGLE
REACH -IN REFRIGERATOR
20A
1
1
15
0.9 0.7
16
1
1
20 A
LETTUCE CRISPER
UNDERCOUNTER HEAT...
20 A
1
1
17;
^' "m, , W.�e " .., 1.1 0.7
18
1
1
20 A
REFRIG. DISPLAY
MICROWAVE
25A
1
1
19
0.2 1.5
20
BREAD WARMER
20A
1
1
21
0.9 1,5
22
2
2
25A
PROOFING CABINET
REFRIG. DISPLAY
20 A
1
1
23
0.7 1.0
24
1
20 A
HAND DRYER - RESTROOMS
SPARE
20A
1
25
0.0 1 0 >„
_
26
1
20 A
HAND DRYER - RESTROOMS
MECH, ROOM GENERAL...
20 A
1
27
0.4 0.2
28
1
1
20 A
REFRIG. EQ. STAND
VESTIBULE HEATER
25 A
2
2
29-�
"g, �� �` 2 0 0 5
30
1
1
20 A
U/C REFRIG
___
2
2
25 A
CHEESE MELTER
HOTWELL-SINGLE
20 A
1
33
1.7 1.8
34
MICROWAVE
25A
1
1
35
s 2.0 0.6
36
1
1
20 A
REACH -IN REFIGERATOR
SPARE
20 A
1
37
0.0 1.0 ..... . ........ ,
38
1
1
20 A
BACK DOOR SECURITY...
-
392
0 1 5
40
1
1
20 A
BACK BAR /STAR BAR...
WATER HEATER
30 A
2
3
41
„ 2.0 1.7
42
1
1
20A
COOK AND HOLD OVEN
SPARE
20 A
1
43
0.0 1.544
44
SPARE
20 A
1
45
0.0 1.5 , � �'
46
_
2
20 A
EXTERIOR WAITING HEATER
_
DECARBONIZING TANK
20 A
1
_
47F
1.0 1 5
48
2
20A
EXTERIOR WAITING HEATER
REMOTE CONDENSING
49
2.3 1.5
50
25A
3
51
2 3 1 5
52
UNITS
53
` 31 2.3 1.5
54
2
20 A
EXTERIOR WAITING HEATER
TOTAL LOAD
18 kVA 20 kVA 22 kVA
AMPS:
153 A 173 A 188 A
LOAD CLASSIFICATION
_TOTAL
CONNECTED
DEMAND ESTIMATED
PANEL
TOTALS
Lighting
1540 VA
125.00% 1925 VA
Other
34486 VA
100.00% 34486 VA
CONNECTED LOAD: 61094 VA
_
RCPT
8520 VA
100.00% 8520 VA
ESTIMATED DEMAND: 56197 VA
SPEC
1704 VA
100.00% 1704 VA
CONNECTED CURRENT: 170 A
_
KTCH
14991 VA
65.00% 9744 VA
EST. DEMAND CURRENT: 156 A
O
1. GF61 BREAKE
5
2.(2) #10 CU, (1) #10 CU EG.
IN 3/4" C
3. (3) #10 CU , (1) #10 CU EG.
IN 3/4" C
PANELBOARD: IG
LOCATION: VOLTAGE: 208Y/120 V. 3 0 4 W.
MOUNTING: SURFACE... A.I.C. RATING: 65,000 AMPS SYMMETRICAL
MAIN DEVICE: 100 A MLO SPECIAL:
BUS AMPS: 100 AMPS
LOAD DESCRIPTION
BKR
P
NOTES
CKT
AkVA PHASE B kVA CAS
CKT
NOTES P BKR LOAD DESCRIPTION
T-.__
SPARE
20 A
1
18.1 kVA RTU -1
1
0.0 1.1 " g
2
1,3 1 20A BUILDING SIGN EXTERIOR
SPARE
20 A
l
_
37.8 kVA RTU -4 -�
3
„• , 0.0 0.0 ''
4
1 20 A SPARE
-
SPARE Y
SPARE
20 A
20 A
1
1
9 225 A 3_ 225 A
5
7
x r' � EF
„ 0.0 OA
0.0 0 0 5 ; �, , -.,'''
�
6
8
0 A
1 20 A SPARE
1 20 A SPARE
_
EXTERIOR LED
A
1
1,3
9
1.0 0.0 ;,',
10
1 20A SPARE
..._..__
SPARE
_20
20 A
1
CONNECTED
11
s,F �4.•.< `" 0.0 0.0
12
1 20 A SPARE
5 KVA UPS / PANEL POS
30 A
20 A
2
1
1,2,3
13
15
17
2.4 0.0 .e.. w._.,
...,. 1.1 0.0
„•,' 0.4 0.0
14
16
18
3 15 A TVSS
-
FRONT ENTRANCE BLDG....
_
RCPT
TOTAL_ LOAD:
TOTAL AMPS:
3 kVA 1 2 kVA 0 kVA
1 31 A I 19A_-, 3 A
44303 VA
LOAD CLASSIFICATION_
LITES
CONNECTED
125.00%
DEMAND ESTIMATED
PANEL TOTALS
Other
10481 VA
112.52%
2513 VA
- CONN. LOAD:
100,00% 2513 VA
KTCH _
50289 VA
RCPT
32688 VA
EST. DEMAND LOAD:
3480 VA
_
100.00% 3480 VA
CONNECTED LOAD: 5888 VA
CONN. CURRENT:
1111 A
-
EST. DEMAND...
ESTIMATED DEMAND: 5888 VA
-
CONNECTED CURRENT: 16 A
NOTES:
1. DESIGN BASED UPON USE OF INTEGRATED RATED RATED BREAKERS TO ALLOW USE OF 10K AT BRANCH
PANELS. PANELS INTEGRATED EQUIPMENT RATING SHALL BE 65K.
2. PRESSURE SWITCH WITH CURRENT LIMITING TYPE FUSES.
3. PROVIDE SHUNT TRIP BREAKER TYPE: 'ED -SHUNT TRIP'
EST. DEMAND CURRENT: 16 A
NOTES:
1. THESE CIRCUTS ARE ROUTED THROUGH SM ART BREAKER ZONE A. TC1.CB
2. COORDINATE INSTALLATION REQUIREMENTS WITH SIGN SUPPLIER.
3. NEON/LED TRANSFORMERS ARE UL 2161 LISTED AND PROVIDE SECONDARY GROUND FAULT PROTECTION ALL GROUNDING FOR THESE
CIRCUITS SHALL BEISOLATED AND DEDICATED COORDINATE WITH SIGN/NEON/LED INSTALLER.
DISTRIBUTION PANEL: MDP
LOCATION: VOLTAGE: 208Y/120 V. 3 e 4 W.
MAIN DEVICE: MLO ALC.... 65,000 AMPS SYMMETRICAL
BUS AMPS: 1000 AMPS SPECIAL:
JOB #
170509
SECTION No. 1
CKT FRAME POLES RATING
-
KVA DESCRIPTIOWNAMEPLATE NOTES
1 60 A 3
60 A
17.6 kVA DISH MACHINE
2 60 A 3 -
60 A
18.1 kVA RTU -1
3 100A 3
-
90A
25.9 kVA RTU -2
_ 4 100A 3
A
25.9 kVA RTU -3 ---
_ _90
5 200 A 3 125 A
_
37.8 kVA RTU -4 -�
6 100A 3_
90 A
25.9 kVA RTU -5
7 225 A--8 225 A
_
46.4 kVA PANEL A
8 225 A_ 3225 A
37.4 kVA PANEL B
9 225 A 3_ 225 A
61.1 kVA PANEL C
10 100A 3 100 A -1.8
kVA PANEL D - 2
11 225 A 3 225 A
_
28.5 kVA PANEL E
12 100A 3 100A
_5.9 kVA PANEL IGTV( SSS
13 225 A 3 225 A
51.7 kVA PANEL S 3
14 100 A 3 100 A
24.1 kVA I BOOSTER HEATER
LOAD CLASSIFICATION
CONNECTED
DEMAND -
ESTIMATED
PANEL TOTALS
Li htmg
2363 VA�
125.00%
2953 VA
Other
260292 VA
100.00%
260292 VA
_
RCPT
78606 VA
56.36%
44303 VA
LITES
1973 VA
125.00%
2466 VA
SPEC
10481 VA
112.52%
11794 VA
- CONN. LOAD:
400206 VA
KTCH _
50289 VA
65.00%
32688 VA
EST. DEMAND LOAD:
351769 VA
_
CONN. CURRENT:
1111 A
-
EST. DEMAND...
976 A
NOTES:
1. DESIGN BASED UPON USE OF INTEGRATED RATED RATED BREAKERS TO ALLOW USE OF 10K AT BRANCH
PANELS. PANELS INTEGRATED EQUIPMENT RATING SHALL BE 65K.
2. PRESSURE SWITCH WITH CURRENT LIMITING TYPE FUSES.
3. PROVIDE SHUNT TRIP BREAKER TYPE: 'ED -SHUNT TRIP'
100 S. Ashley Dr.,
Ste. 100
Tampa, FL 33602
P: 813 - 323 - 9233
Lic. #: AA - 0003590
W: www.bdgllp.com
J ~
D Cy)
0
m Q
w0
Z I.I..
W
U 0
�
W
Z LL
�z
0 cn
0
THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY
CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER
"PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG
ARCHITECTS, AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR
USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF BDG
ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE
CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE
SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT
BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS
WRITTEN APPROVAL OF BDG ARCHITECTS, ANY CHANGES TO THESE PLANS,
REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL
OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF BDG ARCHITECTS; OR ANY
CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY
REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL
AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG
ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND
COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR
DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR
RELATED TO THE PLANS., ANY DISCREPANCIES OR CONFLICTS IN THE PLANS
SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR
CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER
DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO
PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR
DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS. THE
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING
AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY
SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS.
Adam T. Powell, PE
PE0073853
LECTRICAL SEAL 1/4/201810:33:17 AM
ISSUE BY I DATE DESCRIPTION
1 08-24-2017 PERMIT COMMENTS
3 10-16-2017 OWNER COMMENTS
5 01-04-2018 Revision 5
PROJECT INFORMATION BLOCK
JOB #
170509
DATE:
7-6.2017
DRAWN BY:
Author
CHECKED BY:
Checker
SHEET TITLE
ELECTRICAL
SCHEDULES
SHEET NUMBER
L
E601
- I
ITEM # QUANTITY DESCRIPTION MANUFACTURER and MODEL # ELECTRIC GAS WATER WASTE COMMENTS ITEM # QUANTITY DESCRIPTION MANUFACTURER and MODEL # ELECTRIC GAS WATER WASTE COMMENTS
SEE SHOP DRAWINGS FOR EXACT ELECTRICAL REQUIREMENTS
208V/3PH 12 6 AMPS PLUMBING CONTRACTOR FURNISH AND INSTALL CONDENSATE LINES 73. CLEAN DISH TABLET 3 COMPARTMENT SINK ASSEMBLY CUSTOM
1 A, WALK-IN FREEZER _ KOLPAK 208VI1PH 8.7 AMPS FD ELECTRICIAN PROVIDES AND INSTALLS HEAT TAPE FOR DRAIN LINES .112" CW 112" HW FS PLUMBER TO PROVIDE AND INSTALL STANDOFF SUPPORTS FOR DRAIN LINES
_ - 3 ELECTRICIAN BPLUMBERTOCONNECT PC TO RUN DRAIN LINE
208V/3PH 7 4 AMPS
1B. WALK-IN BEER COOLER _ KOLPAK 2081PH 7.9 AMPS FD 74. 2 EA. ICE MACHINES SCOTSMAN EH430SL•1 120V 15 AMP BREAKER 112,CW OD 4") REMOTE CONDENSER REQUIREMENTS SEPARATE
208V/8PH8 8 AMPS
1C, WALK-IN PRODUCTION COOLER _ KOLPAK 115V11PH4.0AMPS FD 74A. 2EA. REMOTE CONDENSING UNITS SCOTSMAN.ECC1800-3 - 208V13PH19AMPS -_-
-zosv/aPH a e AMPS
1D. WALK-IN MEAT COOLER _ KOLPAK 115VNPH 4.0 AMPS FD _ 75. ICE BIN Follet SG3200.72 FS TROUGH DRAIN
76. POWER HUB - UNIVEX PM -91 WINS -9 CHOPPER ATTACHMENT 120V t HP
2, 4 EA, PLASTIC STRIP CURTAINS CURTRON M108PR-4080 _ �
3, GRIDDLE ACCUTEMP EGF208363650-T1 208V13PH 39,56 AMPS 77. 2 EA. BAG -IN -BOX RACKS COCA-COLA 1 CORNELIUS4. CHAR CHAR BROILER VULCANVACB36 314" 102,000 BTU _ 7$. IEA, CARBONATOR -_ COCA-COLA MCCANNSES30091 120V7AMPS, 120V8.3AMPS 112'CW(FROM FILTER) VERIFY ALL DRINK SYSTEM REQUIREMENTS WITH COCA-COLA REPRESENTATIVE lOO S. ASiII@y 813 - 323 - 9233
5. 2 EA. _ CHAR BROILER VULCAN VAC847 314" 136,000 BTU 7$A. 1 EA. _ SIS CARBONATOR SHELF COCA-COLA McCANNS #16.1446 - S1'@. 100 LIC. EPALD
#: AA - 0003590
- - - Tampa,. FL 33602 W: www.bdgllp.com
6A, REFRIGERATED EQUIPMENT STAND WIDRAWERS &CASTERS SILVER KING SKRC879H 120V 3.1 AMPS _ SPECIAL TEXAS ROADHOUSE CONFIGURATION (PANS SIDE X SIDE) 79, WATER FILTRATION SYSTEM EVERPURE C820.312 (FOR SODA SYSTEM _ 314"CW FURNISHED 8Y COCA-COLA WIDRINK SYSTEM
68. REFRIGERATED EQUIPMENT STAND WIDRAWERS &CASTERS SILVER KING SKRC850H 120v 3.1 AMPS SPECIAL TEXAS ROADHOUSE CONFIGURATION (PANS SIDE X SIDE) $O, 1 LOT SHELVING PACKAGE METRO -FOR WALK-INS ABC PROCURMENT C -K FOR DRY STORAGE ALL WIRE SHELVING EPDXY COATED
6G.• SPECIAL TEXAS ROADHOUSE CONFIGURATION PANS SIDE X SIDE) T $1, 1 LOT _ DUNNAGE RACKS NEW AGE MODEL 20XX ��__-"�--------�
SPECIAL TEXAS ROADHOUSE MODEL
7. GRIDDLE COUNTER TOP 24" STAR MFG. 524TGF-DIV 208V11 PH 28,9 AMPS �-_- CORD AND PLUG BY ELECTRICIAN $2. 1 LOT STEAM TABLE PAN RACKS NEW AGE 1505
$, COUNTER TOP COLD PAN CUSTOM STAINLESS STEEL $3. 1 LOT SHEET PAN RACKS NEW AGE #7331 WICASTERS
- _ -
9, 2 EA. 14" DEEP FRYER WICASTERS PITCO SG -14S 314" 110,00OBTUs
$3A. 1 EA COUNTER HEIGHT SHEET PAN RACK WIWORK TOP NEW AGE #1313 WICASTERS 205 N. ARMENIA AVE; #102
TAMPA, FL 33609
10. 2 EA. 18" DEEP FRYER WICASTERS _ PITCO SG -188 _ 39" 140,000 Bios 84. _ DECARBONIZING TANK CLEAN X -PRESS CLEAN7ANK CXP006 - 120v 8.3 AMPS - TEL (813) 995-0300
_ FAX (813).995-0400
10A. FRYER FILTER WICASTERS PITCO P-18 120V to AMPS $5. _ug BEER KEG DOLLIES &STACKERS MICROMATIC KD300, KS200 FLORIDA ENGINEERING BUSINESS #002764
..- - - ---- COPYRIGHT 2016 •EMERALD ENGINEERING
11. ONION BREADING STATION CUSTOM STAINLESS STEEL $6. POT FILLER T&S B•0597 1/2"l _
11A, _REFRIGERATED STAND _ SILVER KING SKRCB50HIC11 120V 3.1 AMPS ON CASTERS $7.
BEER LINES RUN THROUGH UNDERGROUND CHASE FROM INSIDE BEER WALK-IN
_ 12, _ UPRIGHT REACH -IN FREEZER W/CAST_ERS TRAULSEN TR1G•12000 _ 120V 9.7 AMPS ON CASTERS $$. GLYCOL BEER CHILLING SYSTEM CHILL -RITE MLN -33 120V 12 AMPS TO DESIGNATED AREA INSIDE BACK BAR
13. SALAD PASS THROUGH PICK-UP SHELF CUSTOM $$A. - BEER CHILLING SYSTEM SHELF CHILL -RITE -
_14, _ 3 EA. - _MICROWAVE OVENS MENUMASTER MFSI2TS - 120v 15 AMPS 89•
14A. 90. SIS DRINK COUNTER CUSTOM I I I Q
15. REACH -IN REFRIGERATOR WICOLD TOP, CASTERS TRAULSEN UST7230•zTR01-LR 120V 7.5 AMPS 91. GLASSWARE RACKS W%A. T le )
16, UNDERCOUNTER REACH -IN FREEZER TRAULSENULT27 120V7.5AMPS MODIFIED WITH WORK TOP - 92.
17. LETTUCE CRISPER - SILVER KING SK2SB 120V 2,4 AMPS PROVIDE WALL MOUNTING BRACKET 93. 2 EA. ICED TEA BREWERS BUNN TBQ-3 120V 15 AMPS 112"CW FOR ALL DRINK EQUIPMENT _ r.
18• 94. SIS DRINK COUNTER � CUSTOM J N
19. REFRIGERATOR WICOLD TOP, CASTERS TRAULSEN UST279-D 120V 7,5 AMPS -_ ON CASTERS. 95, 2 EA, SODA DISPENSERS COCA COLA BEV-OLUTION DROP-IN WIFS CABINET #44610 120V 12 AMPS 112"CW FILTERED FS PLUMBING CONTRACTOR TO PROVIDE BACK FLOW PREVENTORS
-20. MONKEY DISH SHELF CUSTOM STAINLESS STEEL 96, SIS DRINK COUNTER _ CUSTOM
O
21. _ PASS THROUGH PICK-UP SHELF WIHEATLAMPS SEE 21A & 21C FOR HEAT LAMP SPECS 97. _ 1 EA. COFFEE MAKERS -- BUNN CWTF-TC --- 120V 11,4 AMPS 112"CW
'- --` (2) fiRAL-96 208V 10/120V/1PH 18. 9A
G(a) GRAL-48ll6 208v 10/120V 8.9A VERIFY CONFIGURATION WITH EQUIPMENT SUPPLIER � 9$. 1 LOT ALUMINUM OVERSHELF WIUTENSIL RACK NEW AGE 112*PR
21A, ASSEMBLY COUNTER HEAT LAMPS HATCO: GRAL-96 2 EA.) GRAL-48D6 4 EA.) 1:1AHL-42D3 1 EA. Lim
- V 10/1PQ ILA
2113 99. 1 LOT- ALUMINUM WALL SHELVES NEW AGE 9728* _- � O
SPECIAL INVERTED BRACKETS
21 C. PLATE SHELF HEAT LAMP AND LIGHT BOX _ HATCO GRAH-36D31 EA. HATCO HL -24 1 EA. i is iiNH aeo wArrs --_ - 100. S15 POS STAND ADVANCE TABOO EK -SS -244M �7
Z LL
22, 3 EA. 10 BUTTON MERIDIAN TIMER
22A. _ 8 BUTTON ZAP TIMER - _- - 120V 102. UNDERCOUNTER REFRIGRATOR COMPACT - BEVERAGE AIR VCR27 WI LOW PROFILE CASTERS 120V 4 AMPS � V
2213. 4 BUTTON ZAP TIMER 120V WW
22C. 3 EA. 12 BUTTON ZAP TIMER 120V UIC R TRAULSEN 7 120V .AMPS _ �✓ ♦ z O
`- - INDIRECT CONNECTION TO FLOOR SINK •COPPER PIPING ONLY!II
23. TRIPLE HOT WELLS WIDRAIN WELLS MOD•3007DM 1PH zoavhPH 10.3 AMPS Fs DRAIN LINE AND BALL VALVE BY PLUMBING coNrRAc10R CORD BY ELECTRICIAN 105. FLY FAN BERNER SHC07.1048AA•P 120W1PH 314 HP Z
24. STEAM TABLE COUNTER WIFAUCET CUSTOM STAINLESS SPECIALTIES T&S B-0208 112"HW 1.112"OD EXTEND TO FLOOR SINK -COPPER PIPING ONLYII! 1.06. O
120V 665 WATTS
25, POTATO WARMER WIWARMING SHELF AND HEAT LAMPS CUSTOM WIHATCO GRSBF-30-I & HATCO GRA -30D3 120V 900 WAI r S _ CORD BY ELECTRICIAN 107._.-
_- PLUMBER TO PROVIDE DRAIN LINE FOR ALL KITCHEN CORNERS AND GAPS BETWEEN WALK-INS AND WALLS W
26. 2 EA. COLD WELL DROP-IN CUSTOM -STAINLESS SPECIALTIES FS FOR INDIRECT CONNECTION TO FLOOR DRAIN •COPPER PIPING ONLY! 108. i LOT SIS CORNER GUARDS AND TRIM PIECES CUSTOM
- _ INDIRECT CONNECTION TO FLOOR SINK •COPPER PIPING ONLYII �-
27, HOT WELL W/DRAIN WELLS MOD•100TD -- 120V 13.8 AMPS FS DRAIN LINE AND BALL VALVE BY PLUMBING CONTRACTOR CORD BY ELECTRICIAN 109.
28. 2EA. DIPPER WELL COMPONENT HARDWARE K30-1010 112"1 PC TO PROVIDE INDIRECT CONNECTION TO FLOOR DRAIN -_- 110. P05TERMINALS - OWNER SUPPLIED - 120V2AMPS ISOLATED GROUND -
29. _ SIS ASSEMBLY TABLE CUSTOM - POS PRINTERS OWNER SUPPLIED --_ 120V 1 AMP ISOLATED GROUND
30. 112. CASH DRAWERS OWNER SUPPLIED -
30A. 113,
31, _ 2 EA. CHEESE MELTER _ VULCAN HART 1036C 208VI1PH 17,3 AMPS ELECTRICIAN TO INSTALL NEW CORD AND PLUG 70 REACH OUTLET IF REQUIRED 114, 1 EA. SIS FLOOR TROUGH 96"X 8" GRATE - STAINLESS DRAINS 4'OD, -FURNISHED AND INSTALLED BY PLUMBER THESE DRAWINGS AND PLANS, ANY REPRODUCTION THEREOF, AND ANY
CAD OR ELECTRONIC FILE OF THESE DRAWINGS AND PLANS (HEREINAFTER
32, � COOK AND HOLD OVEN ON CASTERS .ALTO SHAM 150•TH•1 1 208V iPH 14.5 AMPS ON CASTERS WITH POLY CUTTING BOARD TOP 115. _ _I 1 EA, SIS FLOOR TROUGH 72" X B" GRATE STAINLESS DRAINS � 4"OD FURNISHED AND INSTALLED BY PLUMBER "PLANS") ARE THE SOLE AND EXCLUSIVE, PROPRIETARY PROPERTY OF BDG
-
ARCHITECTS. AND MAY NOT BE REPRODUCED, PUBLISHED, MODIFIED OR
- _.__ _ 4"00 FURNISHED AND INSTALLED BY PLUMBER USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF BDG
33. BUN TOASTER STAR BG -3 120y 14,6 AMPS INSTALL SIS SIDE PANELS 116. 1 EA. SIS FLOOR TROUGH 36" x 4" GRATE STAINLESS DRAINS � ARCHITECTS. USE OF THESE PLANS FOR CONSTRUCTION SHALL BE
CONSIDERED ACCEPTANCE OF THE TERMS CONTAINED HEREIN AND THE
34. SIS SALAD PICKUP TABLE CUSTOM - 117. 1 EA SIS FLOOR TROUGH 60" X 8" GRATE _ STAINLESS DRAINS 4"OD FURNISHED AND INSTALLED BY PLUMBER SUITABILITY AND CONSTRUCTABILITY OF THE PLANS. THE PLANS SHALL NOT
BE SCALED OR MODIFIED FOR ANY PURPOSE WITHOUT THE EXPRESS
TUBULAR SUPPORTS IN ALL LOCATIONS WRITTEN APPROVAL OF BDG ARCHITECTS. ANY CHANGES TO THESE PLANS,
35, 4 EA. HAND SINKS ADVANCE TABOO 7 -PS -66, T&S 5F4WLX03 112"CW 112'HW 1.112"IPS INCLUDES SIDE SPLASHES FOR BOTH SIDES -ALL LOCATIONS 1.1$. POT RACK ADVANCE TABOO SW1.24 REGARDLESS OF HOW MINOR, WITHOUT THE EXPRESS WRITTEN APPROVAL
---- "�"""-"--""-""" `-'--- --- -- OF BDG ARCHITECTS; ANY CONSTRUCTION EXECUTED FROM THESE PLANS
35A. _ EYE WASH ATTACHMENT FRONT LINE 5179 112"cw v2"Hw ATTACH To HAND SINK FAUCET 12$. _ 7 EA. EXTERIOR METAL BENCH WABASH VALLEY KE14225•T _- WITHOUT THE EXPRESS WRITTEN APPROVAL of BDG ARCHITECTS: OR ANY
CHANGE IN THE SCOPE, DESIGN, OR INTENT OF THESE PLANS FOR ANY
�- TUBULAR SUPPORTS IN ALL LOCATIONS
129. ADVANCE TABOO SW1.60
35B. HAND SINK WI KNEE PEDAL _ ADVANCE TABOO 7-P5-62, T6S 5F-4WLXo3 v2^cw v2"HW 1.112•!Ps INCLUDES SIDE SPLASHES FOR BOTH SIDES -ALL LOCATIONS 2 EA, POT RACK _ REASON, BY ANY PERSON OTHER THAN BDG ARCHITECTS SHALL
_ AUTOMATICALLY VOID ANY DESIGN -RELATED OBLIGATIONS BDG
35C. HAND SINKS ADVANCE TABOO 7 -PS -23 -EC -5P, TBS 5F4WLX03 112"CW 112"H_W 1.112"IPS INCLUDES SIDE SPLASHES FOR BOTH SIDES -ALL LOCATIONS 1_3_0. _ CHICKEN PREP TABLE CUSTOM SS 18x36 - WI BACKSPLASH a CASTERS ARCHITECTS MAY HAVE ON THE PROJECT, AND RESULT IN THE FULL AND
COMPLETE RELEASE OF BDG ARCHITECTS FROM ANY LIABILITY, CLAIMS, OR
DAMAGES INCLUDING ERRORS AND OMISSIONS ARISING OUT OF OR
36. SIS PICK-UP TABLE CUSTOM 131. - UN E'RCDCIN'TER REF 13ERAT - DELfIELD UCD4432N 120V 3.9A
RELATED TO THE PLANS. ANY DISCREPANCIES OR CONFLICTS IN THE PLANS
SHALL BE REFERRED IMMEDIATELY TO BDG ARCHITECTS FOR
CORD BY ELECTRICIAN 132. CLARIFICATION PRIOR TO CONTINUING WITH THE WORK. FAILURE TO REFER
37, 2 EA HOT WELL (SINGLE WIDRAIN) WELLS MOD-1OOTD -_- 120V 13,8 AMPS ------- _ DRAIN LINE AND BALL VALVE BY PLUMBER •COPPER PIPING ONLY/!!
DISCREPANCIES OR CONFLICTS TO BDG ARCHITECTS PRIOR TO
PERFORMING WORK SHALL RESULT IN THE WAIVER OF ANY CLAIMS OR
3$, REACH -IN REFRIGERATOR WICOLD TOP, CASTERS BEVERAGE AIR SPE60.16 12oV 9.6 AMPS
DAMAGES ASSOCIATED WITH THE DISCREPANCIES OR CONFLICTS, THE
-- '-"'--"
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION, SCHEDULING
39. S/SPICK-UP TABLE CUSTOM
AND CONFORMANCE OF ITS WORK AND ALL WORK PERFORMED BY
-___ -- USE ONLY COPPER DRAIN LINES II FURNISHED $. INSTALLED BY PC SUBCONTRACTORS OR OTHER TRADES WITH THE DESIGN DOCUMENTS.
40. 2 EA, CONVECTION OVENS (DOUBLE STACKED) BLODGETT SHO•G TRH DBL v 120V 6 AMPS 3l4^ 50,000 BTU X2 - CORD AND PLUGS BY ELECTRICIAN A. _ 18" DRAIN BOARD ADVANCE TABOO CRD -18C -SS- 1"IPS ATTACH TO ADJACENT UNIT (ONE SET OF LEGS)
-- -" _ -
USE ONLY COPPER DRAIN LINES II FURNISHED &INSTALLED BY PC
FILTER FURNISHED WITH UNIT,, INSTALLED BY PC (FLUSH WATER LINE PRIOR TO CONNEC710NI( �
B. ICE BIN W17 CIRCUIT COLD PLATE ADVANCE TABOO CRI•16.36.7
41. PROOFING CABINET PIPER PRODUCTS CUSTOM RIP•1•TXR-MANUAL FILL 208VIiPH 16 AMPS TRENCH DRAIN ELECTRICIAN TO FURNISH 81NSTALL CORD &PLUG WITH SEALTIGHT 112" IPS SPEED RAIL CONTINUOUS BETWEEN ICE BIN AND DRAIN BOARD
USE ONLY COPPER DRAIN LINES II
42. UIC HOT CABINET CRESCOR H -339 -SBS -1210C 120V 7.5 AMPS C. SIS SERVICE BAR TOP WIDRAIN PAN CUSTOM 112" IPS FURNISHED & INSTALLED BY PLUMBING CONTRACTOR Adam T. Powell, PE
43. SIS WORK TABLE WI OVERSHELF CUSTOM USE ONLY COPPER DRAIN LINES it FURNISHED 8 INSTALLED BY PC q
1"IPS ATTACH TO ADJACENT UNIT ONE SET OF LEGS) _- PEOO73853
- 5 .E._,._2 EA. 60" MUG FROSTIER PERLICK FR60 120V7.1 AMPS Ii " PO
44. S/S EQUIPMENT STAND WICASTERS ADVANCE TABCO ES -302--- _--------- _ ON CASTERS � F.
G e
COR/ a
� ` �
��'ON ��
ELECTRICAL SEAL 1/4/2018 10:38:40 AM
ON CASTERS�r-.•`c�Ng�F``���i,�
4 BURNER RANGE VULCAN HART VHP848.0100J
314" 120,000 BTU
G.
46.
_
SIS WORK TABLE ADVANCE TABOO TKSS 306
-
_
_-- _.-
OPEN BASE ON SIDE FOR CAN RACK
-H,
BAR HAND SINK WISIDE SPLASHES - _
ADVANCE TABCO SC•15•TS•SS-S _
112"CW 112"HW 1.112" IPS - FAUCET INCLUDED _
-
4$.
_
UIC E AN RACK NEW AGE 1313
1' 1
-
_ J.
SHELF
METRO 24X24 WI INLAYS
K.
DUMP SINK WI DRAIN BOARDS
ADVANCE TABCO PRB-19.31C _
112"CW 112"HW 1.112"IPS to FS USE ONLY COPPER DRAIN LINES !! FURNISHED 81NSTALLED BY PC
49,
TILT SKILLET MARKET FORGE 1200 208V13PH 25AMPS
_
T H00 /BAKERY LC SYSTEMS/ HALTON SEE LC DWGS
-_-
_ _
_-_
L.
1 EA. ��
_SODA GUNS - -
COCA-COLA --�
CONTACT COKE REPRESENTATIVE FOR ANY SPECIAL REQUIREMENTS
51.
- _ _
EXHAUST HOOD (COOKLINE) LC SYSTEMS/ HALTON SEE LC DWGS
FD
INDIRECT CONNECTION TO FLOOR SINK
USE COPPER PIPE ONLYIIII SEE HOOD DRAWINGS FOR DETAILS-
M. _
FROZEN COCKTAIL MACHINE -
TAYLOR 428
120V 13 AMPS
SELF CONTAINED COUNTER TOP UNIT
52,
_ - -_
EXHAUST HOOD DISHWASHING) LC SYSTEMS SEE LC DWGS
SEE HOOD DRAWINGS FOR DETAILS
---
--- -
_
53.
-
..._ -
N.
-
CHILLED BEVERAGE MACHINE _
GRINDMASTER•CECILWARE D25-3 _
120V 5,5 AMPS
ISSUE BY DATE DESCRIPTION
�,
_ _
BREAD PICK-UP SHELF _CUSTOM •SEE ARCHITECTURAL WINDOW DETAILS FOR SIZING
-
�
O.
_
BEER TOWER 9SPIGOT
UNDERCOUNTER9SPIGOT
CUSTOM SIS DRIP PAN MUST BE SEALED WATER TIGHT TO BAR TOP BY INSTALLER
FS USE ONLY COPPER DRAIN LINES /! FURNISHED 8INSTALLED BYPC
3 10-16-2017 OWNER COMMENTS
-
P.
- -- -
----
COUNTER TOP LIQUOR DISPLAY -- -
--
CUSTOM MILLWORK _
-
120V 1PH _-
-_--
ELECTRICAL CONNECTION FOR INTERNAL LIGHTING
5 01-04-2018 R@VI510i1 5
55.
_
REFRIGERATED DISPLAY CASE WI3"CASTERS _ McCRAY SC-4-SSKSD 120V 6 AMPS
-
-.-,-_
CORD AND PLUG 8Y ELECTRICIAN -_
-
-
__R __._-__._
___.._.
UNDER COUNTER REFRIGERATOR -
TRAULSEN UHT27 3
120V 7.5 AMPS
- SIS EXTERIOR
_ 57,
BAKER'S TABLE JOHN BOOS DS808-X
�
5$,
- _
MIXER HOBART HL600.1 208V13PH 10 AMPS
_
ELECTRICIAN TO VERIFY PROPER ROTATION DIRECTION/
CORD BY ELECTRICIAN
R1.
_
UNDER COUNTER REFRIGERATOR
TRAULSEN UHG48-LR-0100•ZTROl -
120V 7.5 AMPS
SIS EXTERIOR
59. _
3 EA.
_ _
HANGING HEAT LAMPS HATCO DL-760CL 120V 250 WATTS -.
-_
ON/OFF SWITCH PART OF NEAT LAMP ASSEMBLY
-._ _._
S.
BACK BAR ASSEMBLY SIS
( )
CUSTOM
- -'-' �--
T.
___...._._
- .-----
60,
MEAT GRINDER UNIVEX PM91 WI ATTACHMENTS 120V 1HR
U.
61,
MEAT CUTTING TABLE ADVANCE TABCO KSS -306 -_, _
-
-_-_-
_ _. __
V.
3 EA.
-..__--_-_-
SPEED RAILS
SUPREME METAL SRK•3
62,
MEAT TENDERIZER LUMAR IDEAL MT -M5 -TR -_
_ -__ __-
_ __--
-_- _ _
PROJECT INFORMATION BLOCK
W.
-- -__ _- _
- -_ _
-
-- -"-
63,
SIS WORK TABLE ADVANCE TABCO KSS -246_---
- --_
___
_._--
_
--- --.--
JOB # 170509
X.
_...._-_
GLASS WASHER
_--_
ECOLAB OMEGA 5E (JACKSON DELTA 5E)
120V 16A
112"141 HW 2`T0 F.S.
COPPER SUPPLY 6 DRAIN TO FLOOR SINK BY P,C.
----
64,
SIS WORK TABLE ADVANCE TABCO KSS -306 _
_
_.
-__-_._-,
__ _ __
DATE: 7-6-20.17
Y.
- _ -
BAR TOP
--- _
CUSTOM MILLWORK PACKAGE
_
65,
2 COMPARTMENT PREP SINK W/DRAIN BOARD ADVANCE TABCO FS•2-2424.24L
_
112"CW 112"HW -
1.112"OD
PLUMBER TO SUPPLY -STAND-OFF SUPPORTS FOR DRAIN LINES
DRAWN BY: Author
_
_.- Z.
BAR OVERSTRUCTURE
------ - -
CUSTOM MILLWORK PACKAGE
-__
-
_
66.
-
CHECKED BY: Checker
67,
_ -- -._-
SIS PREP TABLE ADVANCE TABCO KSS -307
_
_ _-__
_
--.---
_
6$.
3 COMPARTMENT PREP SINK WIDRAIN BOARD ADVANCE TABCO FS -2-2424-24R
112"CW 112"HW
1.112"OD
PLUMBER TO INSTALL STAND OFF SUPPORTS FOR DRAIN LINES _
SHEET TITLE
69,
-
SALAD SPINNER WICASTERS HOBART SDPS-11 - 120V 2.5 AMPS
._, _ -----
__
___- --
ELECTRICAL
KITCHEN EQUIPMENT
SCHEDULE
V C H E D U L E
,__ ------__.,_
___�--___
_
70,
DIRTY DISH TABLE CUSTOM
112"CW 112"HW
FS
PLUMBER TO PROVIDE AND INSTALL STAND-OFF SUPPORTS FOR DRAIN LINES
-
------
71.
PRE -RINSE SPRAYER BK RESOURCES BKF-IMPDR-WB-G
SEE ITEM 81.
-_ _
____- _- _
-
72,
72A.
DISH MACHINE _ ECOLAB ECOTEMP EC44HH 2O8VI3PH 48.75 AMPS T
BOOSTER HEATER ECOLAB C24 208V 3 PH 66.7A
_
314"HW -
112" CW 112 HW
FS
FS
BACK SIPHON PROTECTION ON WATER LINE
ELECTRICIAN TO PROVIDE DISCONNECT IF REQUIRED BY CODE
P.C. TO PROVIDE 314" COPPER ROUGH IN CONNECTION TO BOOSTER, ISOLATION VALVES
AND 3i4" FEED TO DISH MACHINE INLET
�-
E602