Loading...
HomeMy WebLinkAbout100 Towne Center Blvd (fr alarm) (a) 17-2175JAN 9 201 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: e- % Documented Construction Value: $ 7,600.00 - Fire Alarm Job Address- 100 Town Center Blvd. I Sanford, Florida - 32771 Historic District: Yes ❑ No ❑ Parcel ID: Building Permit # 17- 2175 Residential ❑ Commercial Z Type of Work: New ® Addition ❑ Alteration ❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: Permit and Install new Fire Alarm System for the new Restaurant all equipment and drawings supplied by MAPS Security, LLC. Plan Review Contact Person: Rick Lerch Title: DM Phone: 407.679.3332 Name GC Street: City, State Zip: Name VSC Fire & Security Fax: 407.679.1733 Email: salogue@vscfs.com Property Owner Information Phone: Resident of property? : Contractor Information Street: 2401 Lynx Lane City, State Zip: Orlando, Florida - 328014 Name: Street: City, St, Zip: Bonding Company: Address: Phone: 407.670.3332 Fax: 407.679.1733 State License No.: EFA000705 Architect/Engineer Information Phone: Fax: E-mail: _ Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code 0ffect as of that date: _5th Edition (2014) Florida Building Code Revised: June 30, 2015 (�Al ` A \ , O (lJPermit Application TEXAS ROADHOUSE 100 TOWNE CENTER BOULEVARD SANFORD, FLORIDA 32771 Reviewed y e, i rri D..... M�0' �11;: PERMIT (7 -_,21 7s ' V J J Q1 C .0 yy C ._ O $ C W a o!f O v) — C H 4 S - �. o .CC 1.0 LLN-2c. 0 E 0 0 0 N �o oQ z JoC >�° Li Q Leo uwwa U J J Z_ W N� J O ZU� UQ 2w� L� 2 r lLLiU I ZoUzo 3:^ QwZcd- Z 0 Cn D >wU= JUz c E O y C _ Cl) CU M E �NO r- M .� L.1. cc 0 U) Q� Ri -,X ,0 IL F— C U) r Deslgner Date KAN 6/28/17 Drawing Slze Scale 24"x36" Title 1-1-2 1W D WP76 �I �l COVERED EQUIPMENT AREA 002 #2 L / ,-..� Tl ro m I echenlcally LF 11LM1 Val II M1 V -;._ ,. � � I:- Iw u.. _..... �� � MECHANICAL�II'.)11, rOFPIC EEZE @I COOL mal Ili COOLER MEAT COOLER 1 o Look aCa r 113 > a 121 f 12z 11 s -4-4 NAC #4 ;FI LM2 Ima a of P I, E 1 1-4-3 - EOL120 a ,'„' II 5cd 7, Dd LM3 for ActualquIp e a to 1 4 -4-2it l,di.I1 LM4 MITI P - WP _ P WP I Re a eS W C 12ovnc. �-' II, 5 �"� ply�1w . SPE #� 75cd 1-1-1 for RTU s 1-5 (DEDIGATEI3) �I ) _ 1 1� 1 15K EOL p 9' Calling � II 9 Coiling 116 EP - 9 Li �� COLD PR , 1LM6 ' 7 sr GE fo' S W -IN /o 9 Ceiling 11 1LD2 7ml j >......_ __ W.: w._._..n. __..::�..t_ L__ i° ,, , ��I I i RTU -51 II --. -do HOT PREP ''I`' 1 I, _ I ,.. - � I, I II11 1 � 5i� _III I 1 I , ,., _ � _. ,. .1 IIII II � ., I I ,IKI,�p I III I UTDOOR I , I I I1 I �I, I� L III, IL I 1 o III VIII, IIJ IIII XIX I � I I I I r II VIII III I, 117 1 .. I. , �I�I I 1 WAITING ARE � - WAITING r p1l 001... IIII DISH WASHING 106 1 IIII! III, 1.1-3 OOKLINE 76ad ° 1- 2 1 -� 11a 1-3-1 �1'� _ LI �I C TU 41 - 6cd 1 W -� 1 MEN'S . 1 I I I IIII' 1 { 111Iu111i R 9 Calling 1 W I I I 1 los j , �' 1LD3 0 1LM13 C 11� ., WOMENS IIIi1,� 1�, - �____i III 111 1111111 I 108.- C qll 1 � s C� �.,. '� f ', / ,; I I - 1 _.:. ___.(I .Y � 1 I _ _� _ 1 ,1 I IIII,.:, , �� � u' r��lt: ►�� _. L_:� I I I '18' 10"�Celllrtl� ' 8' 10" Calling - 1 76 I�.r f 14.1 I__I_LJI(al �1 . III _ _ 111 �, _ _ J I PICK-UPAREA / a I I :_.:_ 1-1-4 IRFU- Shut-down1, I1I 124 DISPLAY BAKERY 1 ffl>g i. ( r; g '� I 1 11 TATIb-N 9 Collin 1 LD4 126 - - - -� RTU 1 1 LM 10 118od J 1 i1 ,I 1I 'iUN79�ZX75 // 1,.1-6 PASSAGE -_-_ -.!' I. tl .,_ - IIII'"'. - 1.3-3 �;, 126 I L...... Pram; uu 1 Lr _. - 75od A. _RT -3 ��� . '' - �Ieve..., �. tlon � �I) _ ,1 LM 11 Q w � Earles �I � P V \'u h LOBBY HALL 75od 1-1-7 I 1LD LM i '111,11 1- -41W 101 127 1W - - - „J ,...,nl,;.. ,.,. jM 71 VESTIBULE F 1 LM7 V i �� !' C 102 RTU 3 Shut -dawn I� Elevation Varies \ 9' Celling I 1 C j I rt, BAR 106 I I II _ ..,.,- Il1 I' _ � �I. N �� i1 �I w��(�u,���! 1121 D 11 8 Cellln <, 3 Calling _ PILIg III �i 12 3 Calling N 1 6 Ceiling 1 I - 1 LM9 ,.. _ 1LD6 7 p I m ! r _ 4.7K EOL Y NAC #' RTU- 1 III - U2 Shut -down -1 C ? - I 'I DINING AREA, 11 � 1 1-1-8 11'6"Cellln 100 I DINING AREA g 76Dd 1W 711 1-3.5 - C1 W 300 1 C 4.7K EOL I Elevation Varies NAC #1 Elevation Varies , 1 11 - EVAC ----------------- To -_,-----$---------To Resteurant Sound System Shut Down (2) TW Palr -18AWG E -_ 24V(� RETPWR(TTBE1) 24V (+; RET PWR 01)--) ( 0 11NON. 1.TPW-iii. AO POWER (HOT)T811 AO POWER (NEUT) TBI 1 AO POWER (EARTH) T111,1 SCALE; 1/8" = V SYMBOL LEGEND NAC DEVICE 4.7K Water Flow Bell only to sound MOUNTING REQUIREMENTS when water Is flowing and shall QUANTITY continue to sound as long as AC water n inues to flow. continues E FACP shall not be capable of Honeywell silencing Water Flow Bell. VA 1-1-2 1W D WP76 �I �l COVERED EQUIPMENT AREA 002 #2 L / ,-..� Tl ro m I echenlcally LF 11LM1 Val II M1 V -;._ ,. � � I:- Iw u.. _..... �� � MECHANICAL�II'.)11, rOFPIC EEZE @I COOL mal Ili COOLER MEAT COOLER 1 o Look aCa r 113 > a 121 f 12z 11 s -4-4 NAC #4 ;FI LM2 Ima a of P I, E 1 1-4-3 - EOL120 a ,'„' II 5cd 7, Dd LM3 for ActualquIp e a to 1 4 -4-2it l,di.I1 LM4 MITI P - WP _ P WP I Re a eS W C 12ovnc. �-' II, 5 �"� ply�1w . SPE #� 75cd 1-1-1 for RTU s 1-5 (DEDIGATEI3) �I ) _ 1 1� 1 15K EOL p 9' Calling � II 9 Coiling 116 EP - 9 Li �� COLD PR , 1LM6 ' 7 sr GE fo' S W -IN /o 9 Ceiling 11 1LD2 7ml j >......_ __ W.: w._._..n. __..::�..t_ L__ i° ,, , ��I I i RTU -51 II --. -do HOT PREP ''I`' 1 I, _ I ,.. - � I, I II11 1 � 5i� _III I 1 I , ,., _ � _. ,. .1 IIII II � ., I I ,IKI,�p I III I UTDOOR I , I I I1 I �I, I� L III, IL I 1 o III VIII, IIJ IIII XIX I � I I I I r II VIII III I, 117 1 .. I. , �I�I I 1 WAITING ARE � - WAITING r p1l 001... IIII DISH WASHING 106 1 IIII! III, 1.1-3 OOKLINE 76ad ° 1- 2 1 -� 11a 1-3-1 �1'� _ LI �I C TU 41 - 6cd 1 W -� 1 MEN'S . 1 I I I IIII' 1 { 111Iu111i R 9 Calling 1 W I I I 1 los j , �' 1LD3 0 1LM13 C 11� ., WOMENS IIIi1,� 1�, - �____i III 111 1111111 I 108.- C qll 1 � s C� �.,. '� f ', / ,; I I - 1 _.:. ___.(I .Y � 1 I _ _� _ 1 ,1 I IIII,.:, , �� � u' r��lt: ►�� _. L_:� I I I '18' 10"�Celllrtl� ' 8' 10" Calling - 1 76 I�.r f 14.1 I__I_LJI(al �1 . III _ _ 111 �, _ _ J I PICK-UPAREA / a I I :_.:_ 1-1-4 IRFU- Shut-down1, I1I 124 DISPLAY BAKERY 1 ffl>g i. ( r; g '� I 1 11 TATIb-N 9 Collin 1 LD4 126 - - - -� RTU 1 1 LM 10 118od J 1 i1 ,I 1I 'iUN79�ZX75 // 1,.1-6 PASSAGE -_-_ -.!' I. tl .,_ - IIII'"'. - 1.3-3 �;, 126 I L...... Pram; uu 1 Lr _. - 75od A. _RT -3 ��� . '' - �Ieve..., �. tlon � �I) _ ,1 LM 11 Q w � Earles �I � P V \'u h LOBBY HALL 75od 1-1-7 I 1LD LM i '111,11 1- -41W 101 127 1W - - - „J ,...,nl,;.. ,.,. jM 71 VESTIBULE F 1 LM7 V i �� !' C 102 RTU 3 Shut -dawn I� Elevation Varies \ 9' Celling I 1 C j I rt, BAR 106 I I II _ ..,.,- Il1 I' _ � �I. N �� i1 �I w��(�u,���! 1121 D 11 8 Cellln <, 3 Calling _ PILIg III �i 12 3 Calling N 1 6 Ceiling 1 I - 1 LM9 ,.. _ 1LD6 7 p I m ! r _ 4.7K EOL Y NAC #' RTU- 1 III - U2 Shut -down -1 C ? - I 'I DINING AREA, 11 � 1 1-1-8 11'6"Cellln 100 I DINING AREA g 76Dd 1W 711 1-3.5 - C1 W 300 1 C 4.7K EOL I Elevation Varies NAC #1 Elevation Varies , 1 11 - EVAC ----------------- To -_,-----$---------To Resteurant Sound System Shut Down (2) TW Palr -18AWG E -_ 24V(� RETPWR(TTBE1) 24V (+; RET PWR 01)--) ( 0 11NON. 1.TPW-iii. AO POWER (HOT)T811 AO POWER (NEUT) TBI 1 AO POWER (EARTH) T111,1 SCALE; 1/8" = V SYMBOL LEGEND DEVICE DEVICE DESCRIPTION PART # MOUNTING REQUIREMENTS Manufacturer QUANTITY Fire Alarm Control Panels AC Fire Alarm Control Panel Extra Transformer MS-920OUDLS XM24B Surface Mount in Provided Enclosure Honeywell 1 VA Emergency Command Center ECC -50 Mount in Provided Enclosure Honeywell 1 Remote Vic MIC Remote Microphone ECC -RM Mount in Provided Enclosure Honeywell 1 Commnuicator COMM Communicator T07FS Mount in Provided Encllosure Telguard 1 LCD Annunciator B,S WP LCD LCD Annunciator ANN -80 Mount in Provided Enclosure Honeywell 1 Notification Appliances - Visible and A/V Conventional and Smartsync Operation Addressable Input/Output Devices ## C Multi -Candela A/V Notification Appliance, ## - Candela Rating, Ceiling Mounted SPSC 4"x4"x2-1/8" bockbox System Sensor 10 WP Multi -Candela A/V Notification Appliance, ## - Candela Rating, Wall Mounted, Weather Proof SPSRK Mount in Provided Enclosure System Sensor 2 \ / /YWp Multi -Candela Visual Only Notification Appliance, ## - Candela Rating, Wall Mounted, Weather Proof SRK Mount in Provided Enclosure System Sensor 4 \j Multi -Candela Visual Only Notification Appliance, ## - Candela Rating, Wall Mounted SR Single or Double Gang, 4" Square System Sensor 3 © 6" Red Bell, 24 VDC SSM24-6 WBB System Sensor 1 1 LD 1 .1 I I' I1Q 1 n Mou t all Ill Vertically l 1 Coordinate with other trades to avoid spacing issues. Scale: 1/2" - 1' SYMBOL LEGEND DEVICE DESCRIPTION PART # MOUNTING REQUIREMENTS Manufacturer QUANTITY Addressable Analog Smoke & Heat Sensing Devices OP Photoelectric Smoke Sensor SD355 Single Gang, 3,5" Octagon or 4" Square Honeywell 1 2.5A available #18 TW PAIR SOLID E 3 #18 TW PAIR 1.1.1 Sensor Base 1.1-3 1.1.4 1.1.5 1.1 8 1.1.7 Box in Ceiling, SOLID 71 C 75od Duct Smoke Detector D355PL Coordinate with Mechanical Contractor Honeywell 5 Class B B B,S WP B,S 8 / \ B / \ B / \ S g S ®RTS Remote All LED with Test Keyswitch RTS -151 Single Gang Box Honeywell 5 Addressable Input/Output Devices 7F Manual Pull Station BG- 12LX Deep Single Gang Box Honeywell 3 S_.,.- Single Monitor Module MMF-300 4" Square Deep Box Honeywell 5 Control Relay Module CRF -300 4" Square Deep Box Honeywell 5 Peripheral Devices by Others WF Waterflow Switch 750d 75od 1 BB v VS Valve Tamper Switch Supplied By Others WP 3 KH Kitchen Hood System Class B 1LD1 1 1.3.1 1.3.2 1.3.3 1.3.4 1.3.6 1.3.6 1.3.7 DESCRIPTION Class B 75cd C 75od C 75od 711��Gd�B�C 76od C NAC #3 1.071A used from B B,8 B,S wP B,S g,g 4.7KEOL 2.5A available #18 TW PAIR SOLID E 3 #18 TW PAIR 1.1.1 1.1-2 1.1-3 1.1.4 1.1.5 1.1 8 1.1.7 1.1.6 SOLID 71 C 75od 75od C 75od 75W 75W 711 C 711 C LU X IL Class B B B,S WP B,S 8 / \ B / \ B / \ S g S 4,7K EOL 1.224A used from NAC #1 2,5A available 16KEOL L_.----- _. - - - - J D c al O O LLIll 'io_ a S_.,.- SPEAKER#1 14,1 1.4-2 14.3 1.4.4 750d 750d 750d 75od BB v 4.7K EOL 0.612A used from, WP WP WID WP NAC #4 2.5A available Class B 1LD1 ILM1 11LI 1LM3 *_W_^ 4,7K EOL 0.031 A used from F i i NAC #2 2.5A available A P A A A FAC 12(ODTRe :@2@TEE RND-4BEOUT(BB21 R@OUT TB! ,p,- ELO (B+) TBIB LCD COMM comm - C 0 24V IN 1.) MV, IN `g FI- ADIDIN (l AUDIOIN E '•' DATA IN (S% DATAIN I"Ip N -a APNIlk* (MVC% .wNDI MIC E E IE g RTS RTS 2E 2E 1LD4 1L 10 '1Los 1LM9 1 A 0 A : A 0 A y RTS 2E 1 1 LD2 2E E UNIT SHUTDOWN E E E UNIT SHUTDOWN UNIT SHUTDOWN UNIT SHUTDOWN RTS 2E 4a12 1 31LD3 A A o A E UNIT SHUTDOWN CABLE / WIRING CHART CABLE SPECIFICATION TYPE USE DESCRIPTION CONDUCTOR A ADDRESSABLE LOOP #18 TW PAIR SOLID B STROBES #16 TW PAIR SOLID C 24VCD #18 TW PAIR SOLID E CONTROL WIRING #18 TW PAIR SOLID. N ANNUN. NETWORK #18 TW SH PAIR SOLID S SPEAKERS #18 TW SH PAIR SOLID FIRE ALARM SYSTEM NOTES: Scope of work: 1. The fire alarm system must be installed in accordance with plans & New standalone fire alarm system. Fire alarm system meets NEPA 70 - 2011 National Electric Code, Florida Fire Prevention Code 5th ED and Florida Building Code 2014 5th ED. specifications & must meet all state & local code requirements. 2. All wire & cable must be rated per the 2011 Edition of the national electric code section 760 and approved by the manufacturer of the Building Information: fire alarm system. The structure is a NEW 1 story building. 3. All conductors Including shields must test free of opens, shorts & Building is sprinkled. Used Group - A2. Total Interior - 7163 S.F., Occupancy Load 328 Persons. grounds before making connections to the fire alarm control panel. Building is 1 story with varying ceilings heights in the seating areas and 9' in the restrooms. 4. 120vac power to control panel requires a dedicated circuit. Run 3412 (includes the green ground wire) to 1120vac 60hz using 20 amp FIRE ALARM NOTES: circuit breaker. Provide a lock -on clip & red marking on the breaker. 1. System will be "Central Station Service" fire alarm system with an ETL listed Certificate by Sentry 5. Confirm all wiring requirements with fire alarm supplier and Security to be posted within 3' of FACP. provide in accordance therewith. Wire sizes shall be increased as 2. The fire alarm system is power limited. required for voltage drop. 3. All components are UL listed for the purpose intended and cross -listed with the fire alarm control 6. Horns and strobes shall be wired to accomplish synchronous panel. operation. Provide sync modules as required to comply with code. 4. Devices installed outdoors will be UL listed for outdoor installations. 5. Fire Alarm System shall be totally supervised. 7. Duct detectors shall be installed and positioned to allow easy 6. The 121 system feed and telephone lines will have transient suppression. access for periodic Inspection and testing. 7. The system shall have battery backup. The battery back-up system will operate the fire alarm 8. The fire alarm supplier shall provide a copy of the programming under quiescent load for a minimum of 24 hours and then afterwards, sound the fire alarm for 15 minutes codes and operation manuals in a sleeved binder attached to the fire as per NFPA 72 2010ed. 10.5.6.3.1. alarm control panel. 8. All penetrations will be sealed with UL listed fire caulk. 9. The installation shall comply with N.E.C. chapter 760 and N.F.P.A. 72 minimum conduit size is 1/2"' 9. All devices to be field tested with written certification of system. maximum conduit fill is 40%. Perform all tests in the presence of the authority having jurisdiction, 10. Wire used is 16/2 FPLR for Notification Circuits and 18/4 FPLR for initiating circuits as notated on 10. Provide connection to remote supervision as directed for the wire legend, supervision of system in compliance with local authority & owner. 11. Fire alarm control panel is powered by a dedicated circuit breaker with breaker lock and will be Provide all interface required to initiate remote supervision. labeled as "FIRE ALARM CIRCUIT". 11. Provide & install manual stations where required by local 12. Strobe lights are a minimum of 75 cd, Each visual device will have the candela rating listed next to authorities to meet the requirements of NFPA-72 in addition to the it on the plans and riser. Visual alarm per A.N.S.I. Al 17.1.4.26 and the FBC installation complies with devices shown on the plans. FBC. 13. Visual pattern coverage and spacing based upon NFPA 72 - 2010 edition - chapter 18 section 12. Exact location of fire alarm devices must be coordinated with the 1$.5; Visible notification appliances used in the public mode must be located and must be of a type, furniture plan. Bring any coordination issues to the owner for further direction. size, intensity, and number so that the operating effect of the appliance is seen by the intended viewers regardless of the viewer's orientation. NFPA 72- 2010 edition - chapter 18 section 18.51; Visual 13. All speakers to be initially tapped at 1 watts. Adjustments to be notification devices shall be synchronized and shall be required when more than two visual devices are made in the field. seen at a 120 degrees field of view, per NFPA 72. 14. Room where the FACP and Voice Evacuation panel to be 14. Notification appliance circuits (NAC) shall be class "B" style "Y", with an average output of 2.5 installed is mechanically ventilated. amps. 15. The sound level will have at least 15dB above the average ambient sound level or 5dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 1.5m Q Coded Notes: (5ft) above the floor in the occupiable area, using the Arweighted scale (dBA). Sound level will be 1. Install duct detectors in supply air duct. Duct detector greater than 75db at the bedroom pillow with the bedroom door closed. shall shut down air handler upon activation of alarm. III completed NFPA Fire Alarm Certification of Completion and NFPA Inspection forms shall be prepared prior to the final fire inspection. 17. Fire Alarm Log Book will be located near the fire alarm control panel. The log book will contain the following: Log Book Sheet, Operation Manuals, and "As -Built" fire alarm plans. 18.The ETL Certificate will be framed and mounted on the wall WITHIN 36" next to the fire alarm control I panel. 19. Maximum height of control panel and signal power expander is V to top of enclosure AFF. 1 v J C .c. ,_ M co LU X IL o!f �0� �V i ~ 'fA O d H D c al O O LLIll 'io_ a W v cc 0 N �a �0) O O Z JOZ >�° J U � 0 ZUJ > U J J ° z W p ZUr') =Wa°Ln OZ cZ9 U Z O doW�d >w0=� w 0°= E s` . _ (V -v © CD o (� N � CO I~ CO L. M 111 � -moo U o LL p 0 LL LL Q� o 8 o g Designer Dane KAN 6/28/17 Drawing Size Scale 24"x36" FA -00 (aFlrelffeAlLarMS R , 0 O u 4 Circuit Detail e„ayy 0,2720 Honeywellby P �� a » Y �tyt" 1, �1 `_1 I�r ._ { > �"` s- r� .'hay Battery � s i � r o' X 0.4460 "Y. 'F I NAC/Out I t',' Y �' #',. Calculation in Total Sheet 9 "'":, tt A Vk t� ”, ,'S i 1 r$( i, t. Y: t ..i i., ,�, \ tr` f .', iT � N �yal..,.., I ,IF .5.... �; f : a4, =,I�a 9W , n n;xl,.,r, r A"k a a !.,.7» _., ,a. .:.:, .. .'.. ,,. w . x5.e" , ? �;5 v y' ,., .. ala .m ir9 r hal a 41. r. , M. d, "':' h 4+Ik.,. 3{ 2'dti a,+,, ,.. ..,. ,....f,.: �., T s+J, ,..1 .. 5..,11 i..:.. u! nl�x{ -d yt ?NS, f„ t ;.,.. ., Wa, ... st .:, i , t„ ',., x t 4 F 7 3�".'µ: f s +n,',» '� b.T' },':k 4 ,. ,.. ,k.1Y t. tµ «4,,yt3, «+� :YSi;�Rb �� . i$ +. t S ,., t., -p larrn D arwl � X 0.0000 24 Hours r rrrrrr , , ; 'gp- Load a qpqrrent r rrrr r �. r :rrr 3.985 AH 0 X 0.0000 - SPRINKLER VALVE SWITCH T O X 0.0500 R 15 Minutes 1 Watt Alarm 1. tit:,Y, Cur #r X . d a iCl Q Q Am' s ' , r1 4 r � X s A 0.8160 Total t uf"rei rt Load 0 4.843 AH Total t. s A1a i m Lif' •.t d lI 9 � �.. � t� i�i ! r 0 X 0.13:20 - Custom Watt Tap Description 0 X 0,0000 , 5.81 � AY a t Recommended "" e 'ot I €C le}d Batteries- BAT-1270 7A! Y Batteries 01 - IV, .I1x y.. . R , 0 O u 4 Circuit Detail e„ayy 0,2720 by Honeywell 0.2720 1 X 0.4460 "Y. 'F I NAC/Out I t',' Y �' #',. 0 9 "'":, tt A Vk t� ”, ,'S i 1 r$( i, t. Y: t ..i i., ,�, \ tr` f .', iT � N �yal..,.., I ,IF .5.... �; f : a4, =,I�a 9W , n n;xl,.,r, r A"k a a !.,.7» _., ,a. .:.:, .. .'.. ,,. w . x5.e" , ? �;5 v y' ,., .. ala .m ir9 r hal a 41. r. , M. d, "':' h 4+Ik.,. 3{ 2'dti a,+,, ,.. ..,. ,....f,.: �., T s+J, ,..1 .. 5..,11 i..:.. u! nl�x{ -d yt ?NS, f„ t ;.,.. ., Wa, ... st .:, i , t„ ',., x t 4 F 7 3�".'µ: f s +n,',» '� b.T' },':k 4 ,. ,.. ,k.1Y t. tµ «4,,yt3, «+� :YSi;�Rb �� . i$ +. t S ,., t., -p larrn D arwl � X 0.0000 - r rrrrrr 0 r rrrr r �. r :rrr ,rrr 0 X 0.0000 - SPRINKLER VALVE SWITCH T O X 0.0500 R rrr 1 Watt 0�IN X Ur rrrrrr 4 r rrrrrr{ 12 X 0.0630 0.8160 Total .'rta, 1dl.!y '._ na t1! 0 X Total t. s A1a i m Lif' •.t d lI 9 � �.. � t� i�i ! r I • R Y '+, R , ,. r M i; s F �yzt ',.: �1 x ...,':' D � 1V . e r• ,� .,� ;h., s 1 ~v .;, r !u :x.4 +. ,. �a .,. .. h s� r. u, „4, ........ .., „. .. a . t.. .. s .. ,.r. h v .. w>.. .n. • S.K..' �� rrr � r� , .:r .. r_NV a'vr ,.k r., .. :wa30i v.,-..., .,, ,.Y I J e.., S a.. m, � rrrllr � r N 'rrr � r r �{rrr Total Standby Load 111 l N'+ t. ;r k Atat l 1 Loa !r,r NAC/Out 4 , #4 „ar �.0�.T n k 4 y,.aw»>� I a i . .i,, rd � Y 1 ' ., ,. �1 trrrr r rrrrrr �., ar r n R12000 Total , I . ' ,. Y >1a °, Load ! o > aI Alarm Load 0.6 00d1'' FI1re-LlTeALarMS ECC -50/100 Battery Calculation by Honeywell Secondary Powerouro Requirements ent 1. System ECC -601100 Primary Console 1 X.1 0,2720 1 _ 0.2720 1 X 0.4460 = 0.4460 4. Speakers (MaXi=m 50 Watts) 114 Watt 0 X 0.0000 0 X 0.0170 - 112 Watt 0 X 0.0000 - 0 X 0.0330 314 Watt 0 X 0.0000 - SPRINKLER VALVE SWITCH T O X 0.0500 R 1 Watt 12 X 0.0000 4 0,0000 12 X 0.0630 0.8160 2 Watt 0 X 0.0000 - 0 X 0.13:20 - Custom Watt Tap Description 0 X 0,0000 - 0 X 0.0000 Total Watts: '12 Taal Laud 0.:2720 Total Alarm Load 1 1.2620 *I Select only one Additional Amplifier based on whether or net it will be Used for backup purposes. r ECC -50/100 01Y■ Battery 'lM+oI bv Honemell Recommended Batterlesn _ AT� 12120 _ 12AH �atterles SYSTEM OUTPUTS I ANNUNCIATION t a SYSTEM � r EIRE ALARM R � OPERATION MATFRIX Y, G 6 voC) SYSTEM N P U T S NOTIFICATION COMMENTS CONTROL MANUAL PULL STATION SMOKE DETECTOR Al' FACP 0 CID 0 a ® 6b DUCT SMOKE DETECTORS SPRINKLER WATER FLOW SWITCH SPRINKLER VALVE SWITCH �➢ KITCHEN HOOD SYSTE /, qD FACP AC POWER FAILURE 4 FACP LOW 6A'I"EERY 0 OPEN CIRCUIT 0 GROUND FAULT AUDIBLE/VISUAL CIRCUIT- SHORT- ag INITIATING UEVICE CIRCUIT SHORT CEILING MOUNTED SMOKE/HEAT DETECTOR 24" (610rnrn) TO TOP OF LENSE MIN DISTANCE HANDICAP BEDROOM STROBE SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW. FINISHED FLOOR -D E UTC.0 AVIV U TMJ T INCT HEIGHTS PER NF'PA 72 2010 EDITION) A/C SUPPLY OR RETURN DIFFUSER 3' (MIN) (914mm VIN) CEILING AUDIO/VISUAL & VISUAL -ONLY DEVICES MANUAL PULL 80" (ADA) (2032rnm) STATION 80" MIN/96" WAY (20„2 VIIN/2438 MAX \ ACCEPTED HERE TO EXIT DOOR 5' (MAX,) (1524rnrr#) DOOR WIDTH LESS 3 (75rnrn) �J U 7( 15 2 r -n rn) mm mrr# ) MAGNETIC H DOOR ° ' HOLDER F I R E_— aEIULLfDWNN PIONI E JAG K SIN:PLCH 48” MAX (ADA) (1219rnrn) 42" MIN/54" MAX (NEPA) (1067rnrrn MIN/1372mm MAX 4,1 NOTE: MEASUREMENTS —� SHOWN ARE TO THE (102mrn) CLOSEST EDGE OF THE DETECTOR. 4" (102rnm) 12" (MAX) NEVER (305mrn MAX) HERE I WALL MOUNTED SMOKE/HEAT DETECTOR FINISHED WALL SIDE VNALL