HomeMy WebLinkAbout116 E 1st St 18-671 Site plansPROJECT LOCATION-\ INDEX OF DRAWINGS Q SHEET ARCHITECTURAL License # AR0008314 A0.0 COVER SHEET, INDEX &SITE MAP Cell (407) 921-8795 A1.1 LIFE SAFETY FLOOR PLAN AND BUILDING STATISTICS PROJECT DESIGN I INTERIOR DESIGN A2J FLOOR PLAN AND BALCONY LICENSE # ID5296 ' A3.1 ENLARGED FLOOR PLANS, KITCHEN &BAR Voice (407) 341-0489 A4.1 REFLECTED CEILING PLAN FIRST FLOOR &BALCONY MECHANICAL PLUMBING ENGINEER A7.1 BUILDING 6 WALL SECTIONS i w b A8.1 DOOR AND WINDOW SCHEDULE AND DETAILS Adam Joseph Barney, P.E. A9.1 INTERIOR ELEVATIONS Suite #3000 ID2.1 INTERIOR SCHEDULE 8 PLAN Ya' f .wMIR'S MIMIL» MILZARCH, LLC License # AR0008314 Jerry W. Mills 701 West Third Street Cell (407) 921-8795 y rogi PROJECT DESIGN I INTERIOR DESIGN AHKENT DESIGN, LLC LICENSE # ID5296 ' x, 2205 ROCK SPRINGS RD Voice (407) 341-0489 Apopka, Florida 32712 www.ahkentdesign.weebly.com Fax None AHKENTDESIGN@GMAIL.COM MECHANICAL PLUMBING ENGINEER Joseph, Lawrence & Co. LLC i w b CAPTIVEAIRE DETAILS - MECHANICAL Company License #28730 Adam Joseph Barney, P.E. 1180 Harwood Ave Suite #3000 Voice (321) 972-4466 �C k Yea ? M5.5 www.jlceng.com adam.bamey@jlceng.com ELECTRICAL ENGINEER CAPTIVEAIRE DETAILS—MECHANICAL Joseph, Lawrence & Co. LLC M6.1 Consulting Engineers �� =.� Company License #28730 Blake Suddeth, P.E. 1180 Harwood Ave EO.1 Suite #3000 Voice (321) 972-4466 ' • FLOOR PLAN — POWER AND SYSTEMS www.jlceng.com blake.suddeth@jiceng.com FLOOR PLAN — LIGHTING E4.1 RISERS AND SCHEDULES - ELECTRICAL E5.1 DETAILS — ELECTRICAL E5.2 DETAILS — ELECTRICAL E6.1 SPECIFICATIONS - ELECTRICAL i e PLUMBING P0.1 LEGENDS & NOTES — PLUMBING P2.1 FLOOR PLAN - PLUMBING — WASTE P2.2 FLOOR PLAN — PLUMBING - WATER ! . �. �� � 9 1 �► 1111 r o , r � �J 4 b u i A: y4., t&E .". . f � �.^ r �b 5 l���� •3'" -�� K � "' F� ��A z � j� t a, ■ r ■ i ■ MWA M j ARCHITECT MILZARCH, LLC License # AR0008314 Jerry W. Mills 701 West Third Street Cell (407) 921-8795 Sanford, Florida 32771 milzarch@gmail.com PROJECT DESIGN I INTERIOR DESIGN AHKENT DESIGN, LLC LICENSE # ID5296 ' Angela Hayman -Kent 2205 ROCK SPRINGS RD Voice (407) 341-0489 Apopka, Florida 32712 www.ahkentdesign.weebly.com Fax None AHKENTDESIGN@GMAIL.COM MECHANICAL PLUMBING ENGINEER Joseph, Lawrence & Co. LLC Consulting Engineers CAPTIVEAIRE DETAILS - MECHANICAL Company License #28730 Adam Joseph Barney, P.E. 1180 Harwood Ave Suite #3000 Voice (321) 972-4466 Altamonte Springs, Florida 32714 M5.5 www.jlceng.com adam.bamey@jlceng.com ELECTRICAL ENGINEER CAPTIVEAIRE DETAILS—MECHANICAL Joseph, Lawrence & Co. LLC M6.1 Consulting Engineers Company License #28730 Blake Suddeth, P.E. 1180 Harwood Ave EO.1 Suite #3000 Voice (321) 972-4466 Altamonte Springs, Florida 32714 FLOOR PLAN — POWER AND SYSTEMS www.jlceng.com blake.suddeth@jiceng.com _� MECHANICAL M0.1 NOTES AND LEGENDS — MECHANICAL M2.1 FLOOR PLAN — MECHANICAL M3.1 SCHEDULES - MECHANICAL M4.1 DETAILS -MECHANICAL M4.2 DETAILS— MECHANICAL M5.1 CAPTIVEAIRE DETAILS - MECHANICAL M5.2 CAPTIVEAIRE DETAILS - MECHANICAL M5.3 CAPTIVEAIRE DETAILS—MECHANICAL M5.4 CAPTIVEAIRE DETAILS -MECHANICAL M5.5 CAPTIVEAIRE DETAILS—MECHANICAL M5.6 CAPTIVEAIRE DETAILS—MECHANICAL M6.1 SPECIFICATIONS — MECHANICAL ELECTRICAL EO.1 LEGEN AND NOTES — ELECTRICAL E2.1 FLOOR PLAN — POWER AND SYSTEMS E3.1 FLOOR PLAN — LIGHTING E4.1 RISERS AND SCHEDULES - ELECTRICAL E5.1 DETAILS — ELECTRICAL E5.2 DETAILS — ELECTRICAL E6.1 SPECIFICATIONS - ELECTRICAL PLUMBING P0.1 LEGENDS & NOTES — PLUMBING P2.1 FLOOR PLAN - PLUMBING — WASTE P2.2 FLOOR PLAN — PLUMBING - WATER /V1 w n3 jL l me SEAL \ \ \ \. ... .... ....... . .... , \ NO WORK THIS AREA v XwvvvvvvyyvyvMv y D \77 V \ \ TO OPENINGS TO BE BLOCKED Rl OR SCREENED BY OWNER.,�-- `� FE \32 CLR. 1 - --- � _ : _ DISTANCE BETWEEN EXITS 8311 _- -- www.®w wiwws w �.... www�s . sw.�w ..ems... w�...w■ . .�.w ww-� w 46 __ TH Vii -_ �- J+ ..... ......... ....L.. 1 I I _ - 1028 SF/ 15 = MAX. TRAVEL DIST. TO EACH EXIT = ± 46' w......w . .ww.•� w �I�. w wwilsw ..w.�.w w �w� . �� .....e.�.._..- .� w ®wws . �,. -> ... ::: 1 69 OCCUPANTS =� KITCHEN 93, adt -- N _- �' 769 SF/ 200 SNUG PUB \ 4 OCCUPANTS WALK-IN C STORAGE, SF/ soo = BAR COOLER 1OCCUPANTS FE 0 0 _._ �. ..- -- _. -------------- .. --- - - - - - \ A LIFE SAFETY FLOOR PLAN - LIFE SAFETY LEGEND LIFE SAFETY SYMBOLS E- — — - MAXIMUM TRAVEL DISTANCE TO NEAREST EXIT. DIAGONAL DISTANCE OF BUILDING <_ — DISTANCE BETWEEN TWO MOST REMOTE EXITS Tgo sa'o °'S,—. T�"�E TRAVEL DISTANCE TO THE EXTERIOR WAYFINDING DEVICES EXIT LIGHT - WALL MOUNTED FIRE EXTINGUISHERS ® TYPE I EXTINGUISHER W/ CABINET - 4A-60B:C SPECIALTY SIGNALING DEVICES FIRE SPRINKLER SYSTEM - NOT REQUIRED DUCT SYSTEM FIRE DAMPERS ARE INDICATE ON MECHANICAL DRAWINGS, EMERGENCY LIGHTING IS INDICATED ON ELECTRICAL DRAWINGS. FIRE ALARM SYSTEM - NOT REQUIRED. 32" CLF BUILDING STATISTICS & CODE ANALYSIS APPLICABLE CODES FBC TABLE 1004.1.2- AREA ALLOWANCES PER OCCUPANT A. FLORIDA FIRE PREVENTION CODE, SIXTH EDITION, NFPA 1 -UNIFORM FIRE CODE 2017 B. FLORIDA FIRE PREVENTION CODE, SIXTH EDITION, NFPA 101 -LIFE SAFETY CODE, FLORIDA EDITION, 2017 C. NFPA 220- STANDARD ON TYPES OF BUILDING CONSTRUCTION TENANT AREA 1 ST FLOOR: D. FLORIDA BUILDING CODE, "EXISTING BUILDINGS" SIXTH EDITION (2017) CONSTRUC'T'ION TYPE PER FBC (2017) - CHAPTER 6 & TABLE 601 OCCUPANCY CLASSIFICATION PER FBC (2017) & FFPC- SIXTH (2017) TYPE III (UNSPRINKLERED) (PER FBC 903) FBC 303 -GROUP A-2 AND FFPC-NFPA 101-13: EXISTING ASSEMBLY AREA CALCULATION -(2,171 S.F. PLUS 382 S.F. = 2,553 S.F.) FBC TABLE 1004.1.2- AREA ALLOWANCES PER OCCUPANT GROSS AREA AS DEFINED BY FBC 202 (S.F.) TENANT SERVICE AREA: 772/200= 4 OCCUPANTS TENANT AREA 1 ST FLOOR: 2,171 SF 2.553 SQ.FT. TENANT DINING AREA: 1021/15= 69 OCCUPANTS TENANT AREA LOFT FLOOR: 382 SF TENANT STORAGE AREA: 247/300= 1 OCCUPANTS OCCUPANCY LOAD: 74 - SEE LIFE SAFETY PLAN FBC TABLES 508.4 & 716.5- FIRE PROTECTION RATINGS FBC 1005:1- EGRESS WIDTH TYPE OF ASSEMBLY REQUIRED ASSEMBLYOPENING PROTECTION ELEMENT REQUIRED PROVIDED DISTRIB. REQUIRED PROVIDEM REQUIRED PROVIDED OCCUPANCY- 508.4 ( ) X X X X (1005.3.1) STAIRWAY WIDTH: 0.30 x 00= X" X" X" 4 X X X. X" EXISTING FIRE WALLS/ FIRE BARRIERS- 3 X X X GREATER THAN 1 HOUR2 X X X (1005.3.2) OTHER EGRESS WIDTH:0.20 x74 14.8" 32" North 11/2 X X X 32" South SHAFT, EXIT WALLS 2 X X X X" East FIRE BARRIERS -1 HR -SHAFT/ EXIT WALIIS X X X X" West OTHER FIRE BARRIERS 1 X X X 64" CORRIDOR WALLS 1 X X X IBC TABLE 1017.2- EXIT ACCESS TRAVEL DISTANCE 0.5 X X X OTHER FIRE PARTITIONS 1 X X X REQUIRED PROVIDED 0.5 X I X X MAXIMUM TRAVEL DISTANCE (1017.2) 200' 46' SMOKE BARRIERS 1 X X X COMMON PATH OF TRAVEL- (1006.2. 1) X' X' FBC TABLE 803.9- INTERIOR FINISH REQUIREMENTS FBC TABLE 1020.1- CORRIDOR FIRE RESISTANCE RATING EXITS & EXIT PASSAGEWAYS EXIT ACCESS & CORRIDORS ROOMS & ENCLOSED SPACES REQUIRED PROVIDED B - EXISTING C C CORRIDOR FIRE RESISTANCE RATING (1020.1) X HOUR X HOUR FBC TABLE 403.1- REQUIRED PLUMBING FIXTURES MININUM CLEARING OPENING -(1010.1.1) 32" 32" MININUM STAIR WIDTH- (1011.2) 44" 44" 74 OCCUPANTS 37 MEN/ 37 WOMEN FIXTURE TYPE REQUIRED PROVIDED MININUM CORRIDOR WIDTH- (1020.2) 44" 44" MALE FEMALE OTHER MALE FEMALE OTHER MAXIMUM DEAD END CORRIDOR- (1020.4) 50' X" WATER CLOSETS 1 1 - 1 1 X FBC 1006.3.1- MINIMUM NUMBER OF EXITS URINALS X 0 - X 0 - REQUIRED PROVIDED LAVATORIES 1 1 - 1 1 X OCCUPANT LOAD= 74 2 2 DRINKING FOUNTAIN - - X - - X FBC TABLES 1006.3.2 (1) OR 1006.3.2 (2) - SINGLE MEANS OF EGRESS SHOWERS - - X X X X APPLIES SERVICE SINK - _ X X SPACE WITH ONE MEANS OF EGRESS PER 1006.2.1 X NOTES ON PLUMBING CALCULATIONS: STORIES WITH ONE EXIT- (1006.3.2 (2) X URINAL COUNT MEETS 419.2 EXIT ARRANGEMENT PER 1017. 1.1 RATIO MEETS POTTY PARITY 403.1.3 DIAGONAL DISTANCE: (1/2)1/3 DISTANCE DISTANCE BETWEEN EXIT TENANT: 93'-8" 46'-7" 83'-11" NOTE: ALL CHANGES IN LEVELS ALONG ACCESSIBLE ROUTE SHALL NOT VARY MORE THAN 1/2" mi r LUUK rLN Scale: 1/411 1'-0" WbUM bUAKU tAUH 51Ut ■ IN o-�SELECTIVE DEMOLITION NOTES 1. Remove existing portion of wood framed wall/floor as shown. Resupport opening per structural drawings and details. 2. Retain existing windows in place. One pane, one window only, to be replaced with oven hood exhaust, which must run vertically, outside the building to above the roof parapet. Infill for the remainder of this pane shall be infilled with 22Ga galy. Steel and firecaulked around penetration and muntins/ sash. 3. Remove item shown. 4. Retain T&G bead board ceiling, in place. Paint entire ceiling with intumenscent paint in place. Florida Paints shall be utilized for ALL repainting (407)242-4058, Desiree Pedersen. Follow mfr's instructions for all coatings and applications. 5. Retain all existing wood columns in place. 6. Three "new", +four panel wood doors required. Bottom rail of restroom doors shall be cut to match lowered frame opening. Doors shall be salvaged from the Florida Victorian shop, Deland FI (386)734-9300. Mark Shuttleworth. 7. Carefully remove all wall mounted electrical power equipment, fixtures and boxes. Save for possible reuse. See Electrical drawings for further instructions 8. Remove existing compressor/ahu units and relocate per MEP drawings. Coordinate power shut down, with Owner/tenants, only. 9. Remove conduit and wiring. See Electrical drawings for further instructions 10. Provide 2'X3' hinged floor opening, under stair. This work shall be performed FIRST for further investigation of floor framing and brick foundation elements. 11. Retain existing stair, and railing systems in place. Take great care not to damage during construction. 12. Remove existing east/west, ceiling applied duct, and adjacent spiral/round supply duct for all new suspended spiral duct system. NEW CONSTRUCTION / RESTORATION NOTES A. Provide opening to receive oven hood. Carefully cut T&G bead board in a central location of hood, as a test opening to determine existing supporting structure and field solution for framing, Firecaulk between hood and wood ceiling/floor. B. New booths are placeholders for the Owner. GC must coordinate all booth, bar and Snug Pub construction, with Owner in field. Provide Owner with costs, during bidding process. C. All ornamental surrounds and other applied decoration to be provided by the Owner and installed by the GC, under a separate agreement. Owner may wish to self -perform this series of tasks. D. Repaint all existing exposed wood, metal, plaster, drywall. "Florida Paints" products are the design basis for ALL painting requirements. See contact info, above. E. Install PVC vent stacks as required. Coordinate routes up and out with Architect and Engineer, during construction. F. Retain existing pressed metal ceiling in place, prep and repaint, taking great care not to damage. All new electrical and Mechanical shall be suspended and not directly applied to the ceiling. The new light/ fan support attachments shall be made only along the perimeters of the 3'-8"X3'-8" +/- metal panels where supporting wood substructure occurs. G. Sand and refinish all exposed wood floors throughout including stair, but not mezzanine. Satin clear finish 3 coats. Use Lenman Polyurethane Floor Finish. H. 6X6 quarry tile and sanitary base. I. Retain display platform in place, add step, mid height(+/- 7") and create a railing, both sides of stair and across platform. Match mezzanine detailing; height 42". 2. 3 COMPARTMENT SINK 3. ICE BIN 4. DISH RACK ENLARGED FLOORPLAN Scale: 1/4 =1'-0" — L ^a ---- RESTROOM NOTES KITCHEN NOTES r, 3._9,, 3,_9° 3 FE \, �\ 1. SOAP DISPENSER 1. ICE MACHINE 71-611 7,_6„ �. 2. PAPER TOWEL DISPENSER 2. 3 COMPARTMENT SINK 3. FLOOR DRAIN 3. OVER SHELF 4. STORAGE SHELF 4 SHELVES . 13 5. PREP TABLE WITH PREP SINK — - 6. CONVENIENCE PLUG KITCHEN so 7. OVER SHELF 8. HAND SINK 7 - `\..... 9. 36" RANGE WITH OVEN BASE 10. FRYER .......... _- 1 5 ° __ 11. BACK SHELF HOOD (CAPTIVE AIR) WALK-IN $ 12. SAND/SALAD PREP REFRIGERATOR 01_ _) 4COOLER13. DOUBLE OVER SHELF ° \` ` XX \. 14. WALK—IN COOLER/FREEZER ENLARGED FLOOR PLAN 2 Scale: 1/4" =1'-0" ■ ■ � ■ UPPER REFLECTED CEILING PLAN Scale: 1/4" = 1'-0" 'EILING REFLECTED CEILING PLAN BELOW MEZZANINE CEILING & LIGHTING LEGEND II :,11 II - -- -_ - 24' x 24' PRESSED METAL PANELS GYPSUM BOARD CEILING T 4G BEAD 50ARD CEILING MILK GLASS GLOBE 4 52' FAN SUSPENDED ON 4' STEEL PIPE - SURFACE MOUNTED SQUARE COMPACT FLUORESCENT ❑ RECESSED, FLUSH, SQUARE COMPACT FLUORESCENT O RECESSED LED DOWNLIGHT (� SUSPENDED MILK GLOBE FIXTURE ADJUSTABLE LED SUSPENDED TRACK 4 SUPPORT BAR I -O EXTERIOR WALL SCONCE (I EXIT LIGHT NOT ALL DIMMABLE RECESSED DOWNLIGHTS ARE INCANDESCENT (UNLESS SPECIFIED OTHERWISE) SELECTIVE DEMOLITION NOTES 1. Remove existing portion of wood framed wall/floor as shown. determine existing supporting structure and field solution for Resupport opening per structural drawings and details. 2. Retain existing windows in place. One pane, one window O only, to be replaced with oven hood exhaust, which must run coordinate all booth, bar and Snug Pub construction, with vertically, outside the building to above the roof parapet. Infill FE for the remainder of this pane shall be infilled with 22Ga galv. - ------------ --�- Steel and firecaulked around penetration and muntins/ sash. C. All ornamental surrounds and other applied decoration to be 3. Remove item shown. separate agreement. Owner may wish to self -perform this .---- 4. Retain T&G bead board ceiling, in place. Paint entire ceiling D. Repaint all existing exposed with intumenscent paint in place. Florida Paints shall be the design basis for ALL painting requirements. See contact info, above. i utilized for ALL repainting (407)242-4058, Desiree out with Architect and Engineer, during construction. F. Retain existing pressed metal ceiling in place, prep and Digitally signed by Jerry repaint, taking great care not to damage. All new electrical Pedersen. Follow mfr's instructions for all coatings and and Mechanical shall be suspended and not directly applied DN: c -US, o-ldenTrust to the ceiling. The new light/ fan support attachments shall be ' ACES Unaffiliated made only along the perimeters of the 3'-8"X3'-8" +/- metal Individual, cn—Jerry W applications. t Mills, G. Sand and refinish all exposed wood floors throughout including stair, but not mezzanine. Satin clear finish - 3 coats. 5. Retain all existing wood columns in place. Use Lenman Polyurethane Floor Finish. 1=AO 109C0000015EE30 8" 6EC5500004842 I. Retain display platform in place, add step, mid height(+/- 7') ± 1'-2° 6. Three "new", +four panel wood doors required. Bottom rail of -05'00' 2 3/4" 2'-0" restroom doors shall be cut to match lowered frame opening. FLA Doors shall be salvaged from the Florida Victorian shop, 2 Deland FI (386)734-9300. Mark Shuttleworth. A6.1 7. Carefully remove all wall mounted electrical power equipment, fixtures and boxes. Save for possible reuse. See Electrical drawings for further instructions 8. M Remove existing compressor/ahu units and relocate per MEP N drawings. Coordinate power shut down, with Owner/tenants, only. 0 9. Remove conduit and wiring. See Electrical drawings for CV further instructions } 10. Provide 2'X3' hinged floor opening, under stair. This work O O shall be performed FIRST for further investigation of floor framing and brick foundation elements. 11. Retain existing stair, and railing systems in place. Take great O O care not to damage during construction. 12. Remove existing east/west, ceiling applied duct, and FLAT PLASTER adjacent spiral/round supply duct for all new suspended 4" 2'-0" 5'-4" (LOWER). spiral duct system. CEILING (D> NEW CONSTRUCTION / RESTORATION NOTES A. Provide opening to receive oven hood. Carefully cut T&G DATES OJV?Oi1 SEAL701 WEST Third Street, , bead board in a central location of hood, as a test opening to determine existing supporting structure and field solution for framing, Firecaulk between hood and wood ceiling/floor. B. New booths are placeholders for the Owner. GC must coordinate all booth, bar and Snug Pub construction, with Owner in field. Provide Owner with costs, during bidding process. C. All ornamental surrounds and other applied decoration to be provided by the Owner and installed by the GC, under a separate agreement. Owner may wish to self -perform this series of tasks. D. Repaint all existing exposed wood, metal, plaster, drywall. "Florida Paints" products are the design basis for ALL painting requirements. See contact info, above. E. Install PVC vent stacks as required. Coordinate routes up and out with Architect and Engineer, during construction. F. Retain existing pressed metal ceiling in place, prep and Digitally signed by Jerry repaint, taking great care not to damage. All new electrical W Mills and Mechanical shall be suspended and not directly applied DN: c -US, o-ldenTrust to the ceiling. The new light/ fan support attachments shall be ' ACES Unaffiliated made only along the perimeters of the 3'-8"X3'-8" +/- metal Individual, cn—Jerry W panels where supporting wood substructure occurs. t Mills, G. Sand and refinish all exposed wood floors throughout including stair, but not mezzanine. Satin clear finish - 3 coats. 0.9.2342.19200300.100.1. Use Lenman Polyurethane Floor Finish. 1=AO 109C0000015EE30 H. 6X6 quarry tile and sanitary base. 6EC5500004842 I. Retain display platform in place, add step, mid height(+/- 7') Date: 2018.01.31 17:37:47 and create a railing,both sides of stair and across platform. -05'00' Match mezzanine detailing; height 42' . DATES OJV?Oi1 SEAL701 WEST Third Street, , - SELECTIVE DEMOLITION NOTES BOXED OUT DROPPED DUCT 1. Remove existing portion of wood framed wall/floor as shown. TO BE REMOVED 12 j /, g Resupport opening per structural .drawings and details. 2. Retain existing windows in place. One pane, one window i %,i ; ; , o eD f100R SECOND FLOOR nlY,to bre laced with oven hood exhaust which must run SECON i i' ; i f parapet. Infill iabove the roo building to a bo i /141-93/4tide the / /vertical outside / / for fihe remainder of this ane shall be infilled with 22Ga alv. EXIST. CEILING p 9 / / Steel and firecaulked around penetration and muntins/ sash. ,, , / EXISTING. 3. Remove item shown. COVE F F !;!4. Retain T&G bead board ceiling, in lace: Paint entire ceiling WOOD FRAMED 9� P g - p in I. OPEN MEZZANINE LINE with intumenscent paint lace. Florida Paints shall be ;.� / --- - BEYOND ND ....� utilized d for ALL repainting (407)242-4058, Desiree l THROUGHOUT IL1111 I I I[ I[ ICI MEZZANINE Pedersen Follow mfr's instructions for all coatings and pp a lications. -- =- -- D 6-5 314 5. Retain all existing wood columns in place. 2 OPENINGS TO BE BLOCKED17 + panel wood doors required. Bottom rail of �, / EXIST. CEILING 6. Three "new", four pa q OR SCREENED BY OWNER restroom doors shall be cut to match lowered frame opening. Doors shall be salvaged from the Florida Victorian shop, 6 DeLand FI (386)734-9300. Mark Shuttleworth: .EXISTING ; ' ,- EXISTING p WALL ;' / 7. Carefully remove all wall mounted electrical power WOOD FLOOR ---------- ----- / / i -_ __._ _ ... --____ .. - , , _ i ............. equipment, fixtures and boxes. Save for possible reuse. See ......... ._.... - /i 0,- ,� i ; 01.011 � � Electrical drawings for further instructions / 7 ; - - ii/, FIN.FLR. 8, Remove existing compressor/ahu units and relocate per MEP FIN.FLR, / or ower shut down with Owner/tenants drawings. Coordinate power , �T i�---1-Ii—ITT- 17 ——— —— — i, Y. / - 9. Remove conduit and wiring. See Electrical drawings for further instructions 10. Provide 2'X3' hinged floor opening, under stair. This work STEPPED RIBBON CRAWL SPACE shall be performed FIRST for further investigation of floor FOOTING BEYOND framing and brick foundation elements. 11. Retain existing stair, and railing systems in place. Take great care not to damage during construction. 12. Remove existing east/west, ceiling applied duct, and BUILDING SECTION LOOKING WEST adjacent spiral/round supply duct for all new suspended Scale: 1/4" = 1'-,a1 spiral duct system. NEW CONSTRUCTION / RESTORATION NOTES / 12 DROPPED DUCT TO%,.i', A. Provide opening to receive oven hood. Carefully cut T&G / BE REMOVED i i i bead board in a central location of hood, as a test opening to / ;' � ; SECOND FLOOR / / / / i' i / i for and field solution �, supportingstructure SECOND FLOOR determine existing i ;j r i / / � / / framing, Firecaulk between hood and wood ceiling/floor. 14 -931 B. New booths are placeholders for the Owner. GC must EXIST. CEILING / , / / 51-411 coordinate all booth, bar and Snug Pub construction, with F F 11 9 F Owner in field. Provide Owner with costs, during bidding A MANAGERTHROUGHOUT process. WORK AREA 1 - C. All ornamental surrounds and other applied decoration to be 71-31/411 D provided by the Owner and installed by the GC, under a THROUGHOUT 3 -4„ MEZZANINE � separate agreement. Owner may wish to self -perform this series of tasks. 6'-5 3141 / ; ' ; , / / ,���� / / i D. Repaint all existing exposed SEXIST. CEILING wood, metal, plaster, drywall. Florida Paints products are 4 4 6 1 the design basis for ALL painting requirements. See contact / 2 9 G o info, above. THROUGHOUT EXISTING p E. Install PVC vent stacks as required. Coordinate routes up and WOOD FLOOR out with Architect and Engineer, g durin construction. __-_- _. _ __ __-- _ ___--_ .____------------___-______ .._.----____-- F. Retain existing pressed metal ceiling in lace re and 8 H 10 9P 9 place, p --- ..__ --- --- - - --- --- - --- - -- �� 0'-0” --_ / repaint, taking g reat care not to damage. All new electrical FIN,FLR, FIN.FLR, and Mechanical shall be suspended and not directly applied to the ceiling. The new light/ fan support attachments shall be -T >1T --fT - — — — - — — — — — - 7T -- = /; made only along the perimeters of the 3'-8"X3'-8" +/- metal - - panels where supporting wood substructure occurs. — — — — — — — — — — G. Sand and refinish all exposed wood floors throughout STEPPED RIBBON CRAWL SPACE including stair, but not mezzanine. Satin clear finish - 3 coats. FOOTING BEYOND Use Lenman Polyurethane Floor Finish. H. 6X6 quarry the and sanitary base. I. Retain display platform in place, add step, mid height(+/- 7") and create a railing, both sides of stair and across platform. Match mezzanine detailing; height 42". BUILDING SECTION LOOKING EAST Scale: 1/4" = 1'-0" Digitally signed by Jerry W ,z Mins BUILDING SECTIONS ' 4 x �`.� DN: c=US, o=ldenTrust ACES Unaffiliated Individual, cn=Jerry W Mills, SULLIVAN'S PUBLIC HOUSE 0.9.2342.19200300.100.1,1=A 116 E FIRST STREET 0109700000015EE306EC5500 004642 SALFORD, FL 32771 Date: 2018.01.31 17:38:26 100% CDs -05'00' MILZARCT4 LLC 01 31 / 1 S TT TI Tl C i 'CTTT A T T, -T-1" A ,fTT T O 0 T 701 V DAM AWM SEAL NOTE: WALLS STOP AT 5 1/2" ABOVE CEILING WITH NEW 2X6 FRAMING AT 16"OC, AT WOMENS RESTROOM ,ONLY, ADD 518" PWD ON TOP OF 2X6 FRAMING TO CLOSE CEILING STRUCTURE. THIS OCCURS OUT IN FRONT OF THE MEZZANINE. X / - \ X / M M S - WO S RV WO S RV K ? 1/4" HARDIE BEAD BOARD EPDXY PAINTED-, MEN'S RR CEILING IS PAINTED , `; MENS RR CEILING IS PAINTED y 1/4 HARDIE BEAD BOARD T&G BEAD BOARD, EXISTING & HT T&G BEAD BOARD, EXISTING & HT EPDXY PAINTED IS 6'-5 314", WOMENS RR CEILING IS 6-5 3/4 , WOMENS RR CEILING IS MOISTURE RESISTANT GPDW IS MOISTURE RESISTANT GPDW= h AND IS AT 6'- 51/4" AND IS AT 6'- 51/4" i SOUND ATTENTION BLANKET SOUND ATTENTION BLANKET 5/8 MOISTURE RESISTANT 4" DRIP EDGE BAR TOP BAR RAIL GYPSUM BOARD 3/4" QUARTER ROUNDS, BOTH SIDES RESTROOM SIDE `; RESTROOM SIDE WOOD STUD 2X4 @ 12" OC --WOOD STUD 2X6 @ 12" OC F— 2X6 WOOD STUD @ 16"O.C. w 3114x3/4 T&G BEAD BOARD, VERT, 4 C" INSIDE In OUTSIDE } - `;:# EXISTING WOOD FLOOR 1x4 BASE BOARD EXISTING WOOD FLOOR y �,..3/4" QUARTER ROUNDS, BOTH == 0 1-011 ff 11 ff 11 01-011SIDES 01-011 A ' 111Z AFF AFFFFr 77-1D INTERIOR WALL PARTITION - RESTROOM INTERIOR WALL PARTITION PLUMBING LOW WALL PARTITION Scale: 3/4" = V-0" 2 Scale: 3/4" =1-0" Scale: 3/4" =1'-0" HOLLOW METAL DOOR FRAME 3'-4" 1-1 Li to u 0 1 vu u SALVAGED 4 PANEL WOOD DOOR 0 DOOR TYPES & FRAMES Scale: 1/4" =1'-0" WALL LEGEND xx INTERIOR DOOR SCHEDULE DESCRIPTION PLAN VIEW ROOM NAME 2 X 4 WOOD STUD 16" O.C. MAX., WITH SOUND BATT INSULATION IN CAVITY WITH 112" GYPSUM WALL BOARD EXTENDING TO 51/2" ABOVE CEILING. SEE DETAIL 1/A7.1 SYMBOL DOOR FRAME DETAILS HDW NO, FIR E RATING .REMARKS 2 X 4 WOOD STUD 16" O.C. MAX., WITH 1/2" GYPSUM WALL BOARD WITH BAR TOP. SEE DETAIL 3/A7.1 TYPE MAIL WIDTH HEIGHT THICKNESS TYPE MAT'L HEAD JAMB THRESH. FIRST FLOOR EXISTING RECEPTIONMAITING 101A EX EX EX EX EX EX EX EX EX EX EX EXISTING STORAGE 103A 1 EX 3'-0" 6141 EX ` EX EX EX EX EX EX WALK-IN FREEZER 106A EX EX EX EX EX EX EX EX EX EX EX EXISTING REAR 108A EX EX EX EX EX EX EX EX EX EX EX MEN'S RESTROOM 109A 1 WD 3'-0" 6'-3" 1 WD A - SIM. A 1 WOMEN'S RESTROOM 110A 1 WD 3'-0" 6'-3" 1 WD A - SIM. A 1 ADDITIONAL NOTES 1. ALL DOORS ARE TO HAVE LEVER HANDLE TO MEET ADA REQUIREMENTS. 2. PROVIDE CLOSER & KICKPLATE AT FIRE RATED DOORS DOOR HARDWARE SCHEDULE HARDWARE NO. MANUFACTURER & SERIES DESCRIPTION PRODUCT NO. DESIGN FINISH REMARKS SCHLAGE: 1 D-SERIES/ATHENS BATHROOM PRIVACY LOCK: PUSH-BUTTON LOCKING INSIDE ALWAYS FREE TO EXIT. CAN BE OPENED FROM OUTSIDE WITH SMALL SCREWDRIVER. ND40S 8AT 619 HOLLOW METAL DOOR FRAME 3'-4" 1-1 Li to u 0 1 vu u SALVAGED 4 PANEL WOOD DOOR 0 DOOR TYPES & FRAMES Scale: 1/4" =1'-0" WALL LEGEND xx WLegend NO. DESCRIPTION PLAN VIEW 1 2 X 4 WOOD STUD 16" O.C. MAX., WITH SOUND BATT INSULATION IN CAVITY WITH 112" GYPSUM WALL BOARD EXTENDING TO 51/2" ABOVE CEILING. SEE DETAIL 1/A7.1 2 2 X 6 WOOD STUD 16" O.C. MAX., WITH SOUND BATT INSULATION IN CAVITY WITH 1/2" GYPSUM WALL BOARD EXTENDING TO 51/2" ABOVE CEILING. SEE DETAIL 2/A7.1 3 2 X 4 WOOD STUD 16" O.C. MAX., WITH 1/2" GYPSUM WALL BOARD WITH BAR TOP. SEE DETAIL 3/A7.1 EXISTING PLASTER & LATH I; /I 3/4" QUARTER ROUNDS, BOTH SIDES, I JAMBS & HEADS 1"X4" FINISHED SURROUND ,. BLOCKING 6'-5 F ' UNC 1" THICK X WIDTH OF EXISTING WALL, FLUSH TO FACE OF PLASTER AS DOOR FRAME 1X2 STOP- 3 SIDES ---15/8" SALVAGED 4 PANEL DOOR I +/- 6" OR 8" FIELD VERIFY EACH BE RE CONSTRUC NG JAMBS A JAMBDETAIL FIEAD DETAILSIMILAR 10801.M1 10801.M1 10801.H2 108017 3'-0" 10801.D3 3'-6" 2" 10801.J1 s S 11x x x x Q N x ?' x _ x0 x x O d M N _.. M O N Co 10801.886" TiZ. 15 TOE CLEARANCE ' 8' KNEE CLEARANCE 10801.X1 A B 17 19 C D E G TYPICAL RESTROOM MOUNTING HEIGHT REFER TO FBC CH,11 1 Scale: 1/4" -1'-0" RAISED AND BRAILLE CHARACTERS AND PICTORIAL SYMBOL SIGNS (PICTOGRAMS). LETTERS AND NUMERALS SHALL BE RAISED 1/32", UPPER CASE, SANS SERIF OR SIMPLE SERIF TYPE AND SHALL BE ACCOMPANIED WITH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8" (16MM) HIGH, BUT NO HIGHER THAN 2" (50MM). TACTILE CHARACTERS ARE DESIGNED TO BE 4'-8" A.F.F. BUT NOT BE LOWER THAN 48" NOR MORE THAN 60" A.F.F. PICTOGRAM MUST BE 6" MIN. WHEN USED. GRADE 2 BRAILLE ..•:. •. 1132" DIMENSIONAL 0 WOMEW// LETTERS Lo MAY BE 5/8" TO 2" TALL. A B as IGNAGE CRITERIA REFER TO FFE BOOKLET FOR SPECIFICATIONS cale: NOT TO SCALE 10801.132 PT -2 10801.J1 WB -1 42" x A B INTERIOR ELEVATION - RESTROOMS MEN'S AND WOMEN'S AS S Scale: 3/8" = V-0.. C fel SELECTIVE KEYNOTES 10801 TOILET, BATH, AND LAUNDRY ACCESSORIES 10801.68 TOILET TISSUE DISPENSER JUMBO (SURFACE) 10801.D3 PAPER TOWEL DISPENSER (SURFACE) 10801.1-12 SOAP DISPENSER (WALL/SURFACE MOUNTED) 10801.J1 GRAB BAR - STRAIGHT (SURFACE) 10801.M1 FRAMED MIRROR 10801.R1 ROBE HOOK 10801.X1 UNDER LAVATORY GUARD 15001 PLUMBING & MECHANICAL EQUIPMENT AND SYSTEMS 1500112 ACCESSIBLE WALL HUNG LAVATORY 15001.1-12 FLOOR MOUNT TOILET TOILET ACCESSORY SCHEDULE PT•2 WB -1 MANUFACTURER % DESCRIPTION Ell L? 0 TORK 5555290 SURFACE MOUNTED JUMBO ROLL TOILET TISSUE DISPENSER C fel SELECTIVE KEYNOTES 10801 TOILET, BATH, AND LAUNDRY ACCESSORIES 10801.68 TOILET TISSUE DISPENSER JUMBO (SURFACE) 10801.D3 PAPER TOWEL DISPENSER (SURFACE) 10801.1-12 SOAP DISPENSER (WALL/SURFACE MOUNTED) 10801.J1 GRAB BAR - STRAIGHT (SURFACE) 10801.M1 FRAMED MIRROR 10801.R1 ROBE HOOK 10801.X1 UNDER LAVATORY GUARD 15001 PLUMBING & MECHANICAL EQUIPMENT AND SYSTEMS 1500112 ACCESSIBLE WALL HUNG LAVATORY 15001.1-12 FLOOR MOUNT TOILET TOILET ACCESSORY SCHEDULE KYNoT� MANUFACTURER MODEL # DESCRIPTION LOCATION 10801.138 TORK 5555290 SURFACE MOUNTED JUMBO ROLL TOILET TISSUE DISPENSER 1 PER RESTROOM SURFACE MOUNTED PAPER TOWEL DISPENSER (AUTOMATIC 10801.D3 TORK 5510282 TOUCHLESS - BATTERY OPERATED) 1 PER RESTROOM 10801.1-12 TORK 570028A SURFACE MOUNTED SOAP DISPENSER 1 PER PUBLIC RESTROOMS 10801.J1 BOBRICK B-6806 1-112" (38MM) DIAMETER STAINLESS STEEL GRAB BARS WITH 2 PER RESTROOM (36" & 42") EXPOSED MOUNTING - SATIN FINISH. 10801.M1 BOBRICK B-290 MIRROR WITH STAINLESS STEEL FRAME, SATIN FINISH, 18X36 1 PER RESTROOM 10801.R1 BOBRICK B-6727 SURFACE MOUNTED DOUBLE ROBE HOOK MOUNT 1 PER RESTROOM 10801.U2 KOALA KARE K6208-14 (SANDSTONE) SURFACE MOUNTED DIAPER CHANGING STATION 1 PER PUBLIC RESTROOMS 10431.A3 ULINE S-15597 THRU SURFACE MOUNTED PLASTIC SHEET STOCK SIGN. SEE 1 PER RESTROOM S-15599 ELEVATIONS 2A & 2B ON SHEET A9.1. NOTES: ALL TOILET ACCESSORIES SHALL COMPLY WITH FBC CHAPTER 11. r 0 ABBREVIATIONS GENERAL NOTES LEGEND _..----- SUPPLY DIFFUSER. (4 -WAY) X REFERENCE NOTES ABV ABOVE SA SUPPLY AIR 1. INSTALL EQUIPMENT AND MATERIALS IN COMPLIANCE WITH MANUFACTURERS MINIMUM CLEARANCERETURN OR OUTDOOR AIR GRILLE 0 REFERENCE NOTE MULTI DISCIPLINE SHEETS ADJ ADJUSTABLE SF SUPPLY FAN REQUIREMENTSX AND RECOMMENDATIONS. AF- AIRFOIL SDT SMOKE DETECTOR 2. _ COMPLY WITH THE LATEST EDITIONS OF NFPA AND THE LATEST ADOPTED EDITION FLORIDA BUILDING CODE -,h-- FLOW DIRECTION AFF ABOVE FINISHED FLOOR SD SUPPLY DIFFUSER (MECHANICAL, PLUMBING AND GAS). �� EXHAUST GRILLE AC AIR CONDITIONER SDMP SMOKE DAMPER ,INDICATES POINT OF CONNECTION .BETWEEN NEW ACU AIR CONDITIONING UNIT SQ.FT. SQUARE FOOT 3. ALL MATERIALS SHALL FIT THE SPACE AVAILABLE. VERIFY DIMENSIONS AND CLEARANCES ON BUILDING AND EXISTING. AHU AIR HANDLING UNIT IR HA SR SUPPLY REGISTER PLANS PRIOR TO COMMENCING WORK. SUPPLY DUCT UP SECTION (RECTANGULAR) Q POINT OF DISCONNECT. AP A PANEL STR STARTER 4. CONTRACTOR IS RESPONSIBLE FOR TESTING AND BALANCING OF AIR SYSTEMS IN ACCORDANCE WITH AABC BAS BUILDING AUTOMATION SYSTEM SWSI SINGLE WIDTH, SINGLE INLET GUIDELINES. A TEST AND BALANCE REPORT SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL. CONDENSER WATER SUPPLY PIPING. RETURN DUCT UP SECTION(RECTANGULAR)CWS BI BACKWARD INCLINE SZ SINGLE ZONE 5. PROVIDE 45 DEGREE BRANCH TAKE -OFF PER SMACNA FIG. 2-8 ON ALL RECTANGULAR DUCT TAKE -OFFS. BLDG BUILDING TEFC _ TOTALLY ENCLOSED FAN COOLEDCWR 6. PROVIDE AND INSTALL DUCT MOUNTED. HINGED ACCESS DOORS FOR .ALL SMOKE AND/OR FIRE DAMPERS, CONDENSER WATER RETURN PIPING. BHP BRAKE HORSEPOWER TEMP TEMPERATURE NOT OTHERWISE ACCESSIBLE. EXHAUST DUCT UP SECTION (RECTANGULAR) BTUH BRITISH THERMAL UNIT PER HOUR TG TRANSFER GRILLE BCWS BUILDING CONDENSER WATER SUPPLY PIPING. CD CONDENSATE DRAIN T 0 TRANSFER OPENING ABOVE CEILING 7. CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF EACH PIECE OF EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING AND SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO OR �,x� SUPPLY DUCT DOWN SECTION (RECTANGULAR) CFM CUBIC FEET PER MINUTE T STAT THERMOSTAT INSTALLING EQUIPMENT AND MATERIALS. CLG CEILING TYP TYPICAL BCWR BUILDING CONDENSER .WATER RETURN PIPING. CW CHILLED WATER VFDC VARIABLE FREQUENCY DRIVE 8. COORDINATE ALL HVAC SYSTEM DRAWINGS WITH EXISTING/NEW TRUSS TO AVOID INTERFERENCE BETWEEN CONTROLLER MECHANICAL SYSTEMS AND ROOF STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS 1`� RETURN DUCT DOWN SECTION (RECTANGULAR) ( CHWS CWR CHILLED WATER RETURN ASSOCIATED WITH TRUSS INTERFERENCE THAT OCCURS IN THE FIELD DURING CONSTRUCTION. COORDINATE ` CHILLED WATER SUPPLY PIPING. CWS CHILLED WATER SUPPLY VAV VARIABLE AIR VOLUME IN ADVANCE. DUCT SIZES MAY BE REVISED TO FIT TRUSS SYSTEM SO LONG AS THE EQUIVALENT INSIDE SECTIONAL AREA IS NOT DECREASED. CONC CONCRETE VS VARIABLE SPEED .CROSS 1 `r EXHAUST DUCT DOWN SECTION (RECTANGULAR) CHWR CHILLED WATER RETURN PIPING. COND CONDENSATE W WATTS 9. GAUGES AND CONSTRUCTION FOR DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA'S HVAC CONT CONTINUOUS W/ WITH DUCT CONSTRUCTION STANDARDS, HWS HEATING WATER SUPPLY PIPING. CO ` CARBON MONOXIDE W/0 WITHOUT 10. TRANSITION RECTANGULAR DUCTWORK ON BOTTOM AND SIDES. MAINTAIN TOP OF DUCTWORK LEVEL AND SUPPLY DUCT UP SECTIONROUND . ) COP COEFFICIENT OF PERFORMANCE WB WETBULB HIGH AS POSSIBLE. FLEXIBLE DUCT RUN -OUTS TO CEILING DIFFUSERS SHALL BE AS STRAIGHT AS CU CONDENSING UNIT ZD ZONE DAMPER POSSIBLE AND FREE OF SAGS & KINKS. FLEX DUCT SHALL BE THE SAME SIZE AS THE DIFFUSER NECK IT HWR HEATING WATER RETURN PIPING. DB DRYBULB SERVES. SUPPLY DUCT DOWN SECTION (ROUND). DWDI DOUBLE WIDTH, DOUBLE INLET 11. ALL DUCT TRANSITIONS FROM SQUARE TO ROUND SHALL BE SMOOTH SQUARE TO ROUND TRANSITIONS. �� CD CONDENSATE DRAIN PIPING DWGS DRAWINGS SPIN -IN FITTINGS AT THE END OF CAPPED DUCTS ARE NOT ACCEPTABLE. DUCT DIMENSIONS SHOWN ARE DX DIRECT EXPANSION INSIDE CLEAR DIMENSIONS. LINEAR SLOT DIFFUSER R REFRIGERANT PIPING EF EXHAUST FAN 12. THE CONTRACTOR SHALL FULFILL ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SHALL COMPLETE EXH EXHAUST THE WORK SHOWN ON THESE DRAWINGS. ALL SYSTEMS SHALL BE FINISHED, TESTED AND BALANCED, �- 1 EXISTING LINEAR SLOT DIFFUSER (LIGHT LINETYPE) FS FLOW SENSOR. ADJUSTED, AND PROVEN TO BE FULLY OPERATIONAL AND USEABLE. EA EACH EAT ENTERING AIR TEMPERATURE 13. ADJUST ALL DIFFUSERS IN CORRIDORS OR WITHIN THREE (3) FEET OF A WALL TO PROVIDE 2 -WAY OR � RECTANGULAR DUCTWORK WITH TAKE -OFF, BALANCING SP 3 -WAY BLOW AWAY FROM OR PARALLEL TO WALLS. ALL DIFFUSERS SHALL HAVE 4 -WAY BLOW UNLESS DAMPER AND INSULATED FLEXIBLE ROUND DUCT. SAME STATIC PRESSURE TRANSMITTER ASSEMBLY. EER ENERGY EFFICIENCY RATIO NOTED OTHERWISE. A B SIZE AS DIFFUSER INLET UNLESS NOTED OTHERWISE. ELECT ELECTRICAL FIRST DIMENSION IS THAT OF SIDE SHOWN. ENT ENTERING 14. PORTIONS OF DUCTWORK VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED A ROUND DUCTWORK. FLAT. BLACK. EQ ER EWT EQUAL EXHAUST REGISTER ENTERING TEMPERATURE 15. ALL DAMPERS IN AND ABOVE CEILING SHALL BE ACCESSIBLE. CONTRACTOR SHALL COORDINATE ALL ACCESS PANELS IN CEILINGS OR WALLS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND INTERIOR CONICAL FITTING WITH DAMPER ON BRANCH CONNECTION TO RECTANGULAR MAIN (PROVIDE DAMPER IN LOW PRESSURE DUCTWORK ONLY).. �-1/aw, 5 MIN. a^ --- w RECTANGULAR BRANCH DUCT CONNECTION. (PROVIDE BALANCING DAMPER AT ALL BRANCH CONNECTIONS) .WATER DRAWINGS FOR PROPER LOCATION. FC FORWARD CURVED FCU FAN COIL UNIT 16. MOUNT THERMOSTATS WHERE INDICATED ON PLANS 48" A.F.F. UNLESS NOTED OTHERWISE. IN HANDICAPPED EXISTING DUCTWORK TO REMAIN (LIGHT LINETYPE) T- - TEE (PLAN, UP, DOWN). FD FIRE DAMPER ACCESSIBLE AREAS, MOUNT CONTROLS AT 48 ABOVE FINISHED FLOOR. FL FLOOR 17. COORDINATE DUCTWORK AND PIPING WITH PLUMBING, FIRE PROTECTION AND ELECTRICAL. MAKE OFFSETS y R -o ELBOW (PLAN, UP, DOWN). FLEX FLEXIBLE CONNECTOR OR DUCT AND TRANSITIONS TO COORDINATE WITH OTHER TRADES WITHOUT ANY ADDITIONAL EXPENSE TO THE DUCT OFFSETS UP (RISE) IN DIRECTION INDICATED. FPM FEET PER MINUTE CONTRACT. VALVE. F/S COMBINATION FIRE AND SMOKE DAMPER 18. SEAL ALL TRANSVERSE JOINTS AND FITTINGS WITH DUCT SEALER. D DUCT OFFSETS DOWN (DROP) IN DIRECTION INDICATED. FT. H2O FEET WATER GAUGE TWO WAY MOTORIZED CONTROL VALVE. 19. TRAP AND ROUTE CONDENSATE DRAINS LINES, FULL SIZE OF UNIT CONNECTION, AS INDICATED. SLOPE F DEGREES. FAHRENHEIT - 1/8" PER FOOT. GA GAUGE OPPOSED BLADE VOLUME DAMPER (OBD). THREE WAY MOTORIZED CONTROL VALVE. GAL GALLON 20. ALTERNATE MANUFACTURERS AND MODELS WILL BE REVIEWED. THERE MAY BE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL CHANGES RESULTING FROM THE ALTERNATES. THE COST OF IMPLEMENTING AND GALV GALVANIZED ENGINEERING THESE CHANGES SHALL BE BORNE BY THE MECHANICAL SUBCONTRACTOR. MANUAL DAMPER PRESSURE REDUCING VALVE. GPM GALLONS PER MINUTE HP HORSEPOWER 21. PIPE AND DUCT ROUTING SHOWN IS SCHEMATIC. PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS, ]�- FLOW CONTROL VALVE. INCLUDING DIVIDED DUCTS, REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES AS HTWR HIGH TEMPERATURE HOT WATER RETURN ENCOUNTERED IN THE FIELD. IIIII FLEXIBLE DUCT CONNECTION. BALL VALVE FOR PIPING 2 -INCHES AND SMALLER, HTWS HIGH TEMPERATURE HOT WATER SUPPLY BUTTERFLY VALVE FOR PIPING 2-1/2 INCHES AND HW HOT WATER 22. COORDINATE CEILING MOUNTED AIR DEVICE LOCATION WITH REFLECTED CEILING PLAN AND OTHER TRADES.. LARGER. HWR HOT WATER RETURN 23. ALL CONTROL WIRING AND CONDUIT SHALL COMPLY WITH NEC DIVISION 16 SPECIFICATIONS. FIRE DAMPER WITH ACCESS PANEL. BUTTERFLY VALVE. HWS HOT WATER SUPPLY 24. PROVIDE MATERIALS WHICH HAVE A FLAME. SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED HVAC HEATING VENTILATING AND AIR CONDITIONING RATING OF 50 OR LESS WHEN TESTED IN ACCORD WITH ASTM E84. COMBINATION FIRE/SMOKE DAMPER WITH ACCESS PANEL. CHECK VALVE. HV HV25. HEATING AND VENTILATING KW INCHES WATER GAGE KILOWATTS SLEEVE AND FIRE STOP PENETRATIONS THROUGH FIRE RATED SYSTEMS TO MAINTAIN RATING OF SYSTEM. USE MINIMUM GALVANIZED STEEL GAUGE DUCT AS REQUIRED TO MAINTAIN RATING OF SYSTEM. - - - EXISTING DUCTWORK TO BE REMOVED (DASHED LINETYPE) STRAINER. LAT LEAVING AIR TEMPERATURE 26. THE TABC SHALL BE EMPLOYED DIRECTLY BY THE GENERAL CONTRACTOR WHO SHALL BE SOLELY - - _ BALANCE VALVE WITH INTEGRAL TAPS FOR CONNECTION Q LD LWT LINEAR DIFFUSER LEAVING WATER TEMPERATURE RESPONSIBLE FOR ITS PERFORMANCE AND THE TIMELY SCHEDULE OF ITS OPERATION. DUCT MOUNTED SMOKE DETECTOR PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY MECHANICAL CONTRACTOR. REFER TO SPECIFICATIONS FOR OF DIFFERENTIAL PRESSURE METER. VALVE SHALL HAVE NAMEPLATE INDICATING WATER FLOW RATE VERSUS �7C 27. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH CONTROL REQUIREMENTS. VALVE PRESSURE DROP. Joseph, Lawrence & Co MAX MAXIMUM OF THE DUCT SHALL BE IDENTIFIED ON A PERMENANT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FEET OF THE EXHAUST DUCT CONNECTION. AIR DEVICE TAG A AUTOMATIC FLOW CONTROL VALVE WITH INTEGRAL C Iiinq Engineers Consulting MBH 1000 X BTUW A-100 TEMPERATURE AND PRESSURE TEST PORTS. MIN MINIMUM 28. CONTRACTOR TO ORDER ALL FIRE/SMOKE DAMPERS WITH INTEGRAL SMOKE DETECTORS AND END STOP ITA ONTE AVE., SUITE 3000 aLTAMONTE SPRINGS, FLORIDA 32714 MVD MANUAL VOLUME DAMPER INDICATOR OPTIONS. VERIFY VOLTAGE WITH ELECTRICAL DRAWINGS. IF BUILDING IS EQUIPPED WITH FIREH SIDEWALL TRANSFER GRILLE --1 F I UNION, 321.972.4466 rWW.JLCENG.CO wwA MZ MULTI -ZONE ALARM SYSTEM ALL FIRE/SMOKE DAMPERS WILL BE CONNECTED TO BUILDING FIRE ALARM SYSTEM. NO. 8730 CA NO. 2$730 N.T.S. NOT TO SCALE � SIDEWALL SUPPLY REGISTER VENTURI FLOW METER. �"'' �",��, �....... _._....JLC 17.0258.00 ­._­'_. '] OA OUTSIDE AIR OBMVD OPPOSED BLADE MANUAL VOLUME ENERGY CALCULATION VALUES ���JJ SIDEWALL RETURN GRILLE OR OUTSIDE AIR LOUVER PRESSURE AND/OR TEMPERATURE PORT'' \,\cerus DAMPER No. 69124 OPD PROP OPEN DRIP PROOF PROPELLER SIDEWALL EXHAUST GRILLE THERMOMETER. �` 2 dam J Barney 111:03-05'00' ROOF: R-30 NOTE:ORID 0 STATE OF ((� PCR PRE -CONDITIONED AIR SYSTEM WALLS: R-12 RETURN WATER WINDOWS: THIS PROJECT HAS MET THE MINIMUM ENERGY CODE TS WALL MOUNTED DDC TEMPERATURE SENSOR PRESSURE GAUGE WITH GAUGE COCK. �''�,SIONAI PCS PERCENT SHGC: 0.5 REQUIREMENTS AND HAS BEEN DESIGNED TO THE MINIMUM MOUNT 4'-0" ABOVE FINISHED FLOOR. `��` 1"111 This „°mhnsb°°�°°°.r°°`°..Y°a°°'°°°`°°°abY Adam Joseph Barney U VALUE: U-0.5 VALUES NOTED. ALL MATERIALS USED IN THE CONSTRUCTION OF $I nga B msy.PB° �" D t° ndl° P sr mps"°w° ust°B°s Bredagntme ument °t°d°pdt P.E. #: 69124 PD PRESSURE DROP VLT: 0.39 THIS PROJECT MUST MEET OR EXCEED THE MINIMUM VALUES WALL MOUNTED THERMOSTAT FLEXIBLE CONNECTION. d "°r��.d®rede3ed and d°°d l" ses Wre mu6 b° signature °rlf °d°°°°y°°�rr°°��P°° PERF. PL. PERFORATED PLATE DOORS: R-3 NOTED PER THE LATEST ADOPTED EDITION OF THE FLORIDA FLORIDA ENERGY CODE. (D MOUNT 4'-0" ABOVE FINISHED FLOOR. FLOORS:. R-3 BUILDING CODE AND PLBG PLUMBING PRESSURE RELIEF VALVE. PSIA POUNDS PER SQUARE INCH © WALL MOUNTED CO SENSOR QQ __ LEGCSC. ENDS NOTES - MECHANICAL ABSOLUTE MOUNT 4'-0" ABOVE FINISHED FLOOR. Pm� MOTORIZED ACTUATOR PSIG POUNDS PER SQUARE INCH WALL MOUNTED DDC HUMIDITY SENSOR GAUGE MOUNT 4'-0" ABOVE FINISHED FLOOR. RA RETURN AIR � OPENING IN WALL ABOVE CEILING. SULLIVAN'S PUBLIC HOUSE RD RADIATION DAMPER os WALL MOUNTED HUMIDISTAT SENSOR MOUNT 4'-0" ABOVE FINISHED FLOOR. AH r- EQUIPMENT 116 E FIRST STREET REG REGISTER e TYPE `- MARK EQUIPMENT TAG SANFORD FL 32771 REQ'D REQUIRED A PHOTO DETAIL OR SECTION IDENTIFICATION TARGET RG RETURN AIR GRILLE B A = DETAIL NUMBER. B = SHEET NUMBER ON WHICH DETAIL IS LOCATED. 1" DOOR UNDER CUT. ARROW INDICATES DIRECTION �0 CDS 100% RH RELATIVE HUMIDITY UC OF FLOW RPM REVOLUTIONS PER MINUTE RD RADIATION DAMPER INSTALLED MILZARCH, LLC 01/31/18 RR RR RETURN AIR REGISTER R R IN AIR DEVICE JERRY WALKER MILLS, SR. ROOFTOP RD RADIATION DAMPER INSTALLED NOTE: SHEET IN DUCT. SYMBOLS SHOWN ON THIS 407.921.8795 MILZARCH GMAIL.COM NOTE: GENERAL NOTES ON THIS MECHANICAL SHEET ARE FOR MECHANICAL LEGEND ARE ELBOW WITH TURNING VANES FOR REFERENCE PURPOSES ONLY. -AR0008314 Mo. 1 GENERAL REFERENCE PURPOSES ONLY. ALL OF THESE E NOTES MAY NOT BE USED FOR THIS PROJECT. ALL OF THESE SYMBOLS MAY BE USED FOR THIS PROJECT. NOT 701 WEST Third Street, Sanford, Fl. 32771 DATE- 8nr101.1 SEAL kill—, n� 2 _ NE C NEW ICE MAK( CONDENSI MEZZANINE FLOOR PLAN - MECHANICAL cocass Scale: 1/4 = 1'-0" REFERENCE NOTES: o 0 -10"0 GREASE EXHAUST DUCTS ROUTE TO CHASE THROUGH MEZZANINE, THROUGH MEZZANINE WINDOW, THEN UP TO ROOF DUCT. SEE MEZZANINE PLAN FOR CONTINUATION. 0 ROUTE FULLY INSULATED REFRIGERANT AND CONDENSATE LINES FROM AIR HANDLING UNIT TO EXTERIOR CONDENSING UNIT. TERMINATE CONDENSATE IN GREEN SPACE. INSTALL NEW CONDENSING UNIT AND ROOF STAND PER DETAIL SHEET M4.1. COORDINATE CONDENSING UNIT LOCATIONS WITH EXISTING EQUIPMENT AND WITH OWNER. 0 ROUTE OUTSIDE AIR DUCT THROUGH BUILDING SIDEWALL AND TERMINATE WITH OUTSIDE AIR INTAKE LOUVER L-1. COORDINATE EXACT MOUNTING ELEVATION AND LOCATION OF LOUVER WITH ARCHITECTURAL DRAWINGS. 6O ROUTE EXHAUST DUCT THROUGH BUILDING SIDEWALL AND TERMINATE WITH SIDE WALL CAP. U7 1" INTERNALLY LINED SPIRAL DUCTWORK. TYPICAL. PROVIDE NEW FULLY DIGITAL 7 DAY PROGRAMMABLE TYPE THERMOSTAT WITH AUTO CHANGE OVER AND AUTO SET BACK. MOUNT THERMOSTAT 4'-0" ABOVE FINISHED FLOOR. 34"x20" AHU-1 RETURN DUCT WITH 3006 FILTERED RETURN GRILL. 10 30"x20" AHU-1 SUPPLY DUCT UP TO CEILING. 11 14"02" MAKE UP AIR DUCT UP THROUGH MEZZANINE. REFER TO MEZZANINE FLOOR PLAN. 12 ICE MAKER AND COOLER CONDENSERS TO BE MOUNTED ON ROOF RACK. 13 NEW COOLER EVAPORATORS TO BE PROVIDED BY OWNER. 14 EXHAUST FAN UTILITY SET EF -1 LOCATED ON ROOF. 15 ROUTE REFRIGERANT PIPING OVER ON STANDS AND DOWN BUILDING SIDEWALL GREASE DUCT NOTES: 1. DUCT SYSTEMS SERVING EXHAUST HOODS THAT REMOVE SMOKE AND GREASE—LADEN' VAPORS SHALL BE CONSTRUCTION OF AND SUPPORTED BY STEEL OF 0.0598 INCH THICKNESS OR STAINLESS STEEL OF 0.0478 INCH MINIMUM THICKNESS, OR OTHER MATERIAL OF (EQUIVALENT STRENGTH, FIRE AND CORROSION RESISTANCE AS APPROVED BY THE CHIEF MECHANICAL INSPECTOR. DUCTS CONSTRUCTED OF MATERIAL THAT ARE SUBJECT TO CORROSION SHALL BE SUITABLY PROTECTED WHEN INSTALLED OUTDOORS. 2. WELDED ROUND GREASE EXHAUST DUCT UP FROM KITCHEN HOOD. PROVIDE WELDED GREASE DUCT WITH 2 HR. PROTECTION TO COMBUSTIBLES PER N.F.P.A. OR PER GREASE DUCT FIRE WRAPPING DETAIL. SLOPE GREASE DUCT TO HOOD A MINIMUM 1" PER FOOT. WELDED DUCT PROTECTION TO COMBUSTIBLES SHALL MEET STATE, LOCAL AND FIRE CODES.' TRANSITION AS REQUIRED, PROVIDE ACCESS PANELS AT EVERY CHANGE IN DIRECTION AND EVERY 20' MINIMUM. 3. TRANSITION MAIN MAKEUP AIR DUCT DOWN TO KITCHEN EXHAUST HOOD MAKEUP AIR DUCT TAP. PROVIDE MANUAL VOLUME DAMPER ON MAKEUP AIR HOOD TAPS FOR BALANCING PURPOSES. TYPICAL FOR ALL HOOD MAKEUP AIR TAPS.. SEE HOOD FOOD SERVICE DRAWING. 4. MECHANICAL CONTRACTOR TO INSTALL WRAPPER PANELS ON ALL EXHAUST HOODS. FIELD VERIFY AND COORDINATE WITH ARCHITECTURAL PLAN EXACT HEIGHT OF WRAPPER PANELS. PROVIDE NON—COMBUSTIBLE CEILING GRID MATERIAL WITHIN 18" OF HOODS. 5. DUCT SYSTEMS SHALL BE DESIGNED AND INSTALLED IN A MANNER THAT PROVIDES AN AIR VELOCITY WITHIN THE DUCT SYSTEM OF NOT LESS THAN 1,500 FEET PER MINUTE. CSC Josepk, Lawrence & Co Consulting Engineers 1180 NARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCING.COM CA NO. 28730 J Bq����, JLC 17.0258.00 PM..,... R,v QQ, \.10ENSE i No. 69124 Adam J Barney .gyp STATE OF (Vw` 2018.01.31 15:11:34-05'00' FtORIOI'.• ' /ONAL E rn hbin /01111 00\\ Adam Joseph Barney This tam been electronically signed and sealed by C �{ Adam J. Barney, PE on the Date and/or Time Stamp shown P, E • m, 69124 using a digilat signature.. Printed copies of this document am lF 69 not considered signed and sealed and the signature must be verified on any electronic copies -----._....,.,._,..... ......._.,�................_ i AIR BALANCE EXHAUST, EF -1 1,200 CFM EF -1 80 CFM EF -1 80 CFM EXHAUST TOTAL: 1,360 CFM MAKEUP AIR, AHU-1 750 CFM MAU-1 900 CFM MAKEUP TOTAL: 1,650 CFM SPACE PRESSURE = +290 (WITH ALL FANS ACTIVATED) FLEX DUCT SCHEDULE CFM FLEX SIZE MARK DESCRIPTION FACE SIZE OCC. FACTOR 0-50 4"0 51 - 100 6"0 101 - 200 81#0 201 - 400 10"o 401 - 600 12"0 601 - 900 14"0 901 - 1,300 16"0 AIR DEVICE OUTSIDE AIR CALCULATIONS LOUVER SCHEDULE MARK DESCRIPTION FACE SIZE OCC. FACTOR AHRAE 62 VALUES SPACE SPACE OUTDOOR AIR OUTDOOR AIR CLASSIFICATION OCCUPANCY/ 1000 SQFT. PER TABLE 6-1 I AREA LOAD REQUIRED (SQFT) (PERSONS) SUPPLIED SEE SCHED. ALUMINUM (PERSONS) Az Pz (CFM) (CFM) Rp Ra WEIGHT 2: PROVIDE RAPID MOUNT FRAME FOR PLASTER AND SHEET ROCK CEILINGS. L-1 OUTSIDE AIR 3. SUPPLY COMPLETE FACTORY INSTALLED 1/2" THICK FOIL BACKED INSULATION. 1.83 PUB DINNING AREA 70 7.5 0.18 1,954 96 1,071 1,075 STORAGE 0 0 0.12 123 0 14 20 TOTAL EF -1 KITCHEN HOOD UTILITY SET_' 2,077 96 1,085 1,095 NOTE: 1,347 115/10 REQUIRED OUTDOOR VENTILATION AIR VALUES TAKEN FORM ASHRAE 62, TABLE 6-1. 15.4 VENTILATION BREATHING ZONE FORMULA: Vbz = RP * Pz + Ra * Az 263 CAPTIVEAIRE Pz = OCCUPANCY FACTOR * SPACE AREA 1., 2. 3., & 5. NOTE: AREA DOES NOT INCLUDE RESTROOMS AND SHOWER ROOMS. CABINET AIR DEVICE SCHEDULE LOUVER SCHEDULE MARK DESCRIPTION FACE SIZE NECK MATERIAL MANUFACTURER & MODEL NO. NOTES A SUPPLY TURBO NOZZLE 12"0 SEE PLAN ALUMINUM SEIHO NT 12 1. B LOUVERED FACE SUPPLY DIFFUSER 12"02" SEE SCHED. ALUMINUM PRICE #ASCD 1., 2., 3., & 4. C EGGCRATE RET./EXH.. GRILLE (1/2"0/2"x1/2") 12"02" SEE SCHED. ALUMINUM PRICE #80 1. & 2. NOTES: FLA SONES 1. COORIDINATE SURFACE FINISHES WITH ARCHITECTURAL DRAWINGS. GRILLES TO BE PAINTED SAME COLOR AS CEILING. WEIGHT 2: PROVIDE RAPID MOUNT FRAME FOR PLASTER AND SHEET ROCK CEILINGS. L-1 OUTSIDE AIR 3. SUPPLY COMPLETE FACTORY INSTALLED 1/2" THICK FOIL BACKED INSULATION. 1.83 24"x22" 4. PROVIDE REMOTE DAMPERS FOR AIR DEVICE IN HARD CEILING. 0.09 RUSKIN ELF6375DXD MADE-UP AIR FAN SCHEDULE LOUVER SCHEDULE MARK SERVICE AIR FLOW (CFM) FREE AREA (SF) W x H (IN) MAX. VELOCITY IN FPM MAX. PRESSURE DROP (IN H20) MANUFACTURER & MODEL NO. NOTES T.S.P. HP/WATTS R.P.M. VOLTS/PH FLA SONES COOLING COIL WEIGHT MANUFACTURER L-1 OUTSIDE AIR 1,400 1.83 24"x22" 767 0.09 RUSKIN ELF6375DXD 1. & 2. NOTES: 1. PROVIDE BIRD SCREEN. 2. PROVIDE GRAVITY BACK DRAFT DAMPER ON INTERIOR SIDE OF LOUVER. MADE-UP AIR FAN SCHEDULE FAN SCHEDULE AREA SERVED TYPE CFM T.S.P. HP/WATTS MARK AREA SERVED TYPE CFM T.S.P. HP/WATTS R.P.M. VOLTS/PH FLA SONES COOLING COIL WEIGHT MANUFACTURER & MODEL NO. NOTES SINGLE POINT UNIT UNIT INFORMATION -T-CAPTIVEAIRE FLA LOCATION MAU-1 KITCHIN DIRECT 900 0.5 1 HP 823 115/10 10.2 16.5 EF -1 KITCHEN HOOD UTILITY SET_' 1,200 1.5 0.75 HP 1,347 115/10 8.8 15.4 UNIT SIZE 263 CAPTIVEAIRE DU85HFA 1., 2. 3., & 5. EF -2 RESTROOM CABINET 80 0.1 5.5 WATTS - 120/10 - <0.3 AIR TEMP. 11.9 PANASONIC FV-05-11VKS1 1., & 4. EF -3 RESTROOM CABINET 80 0.1 5.5 WATTS - 120/10 - <0.3 11.9 PANASONIC FV-05-11VKS1 1., & 4. NOTE: IPRESS. (F' DB/WB) 1. PROVIDE WITH VIBRATION ISOLATOR KIT, SUSPENDED MOUNTING HARDWARE. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECT. (B UHR 2. HOOD FAN SYSTEMS SHALL START AUTOMATICALLY ON THE EVEN COOKING EQUIPMENT BELOW THE HOOD IS ACTIVATED. INTERLOCK HOOD EXHAUST SYSTEM WITH COOKING EQUIPMENT AND HOOD MAKEUP AIR SYSTEM. AHU-1 3. VERIFY EXACT HOOD FAN INFORMATION WITH KITCHEN EQUIPMENT DRAWINGS. 5,000 1 750 1 1 BELT 1 2.9 178.0/63.0152.8/52.4 4. RESTROOM EXHAUST FAN TO BE CONTROLLED BY LIGHT SWITCH. 1 THROWAWAY 1 30% 1 2 1 208/3 115.0 1 1 1208/31 61.5 1 70 1 56 x49 x28' 695 CARRIER 40RUA014 HORIZONTAL 1. NOTES: 5. PROVIDE WITH FACTORY 5 AMP 115 VOLT SPEED CONTROLLER. MADE-UP AIR FAN SCHEDULE MARK AREA SERVED TYPE CFM T.S.P. HP/WATTS R.P.M. VOLTS/PH FLA SONES WEIGHT MANUFACTURER & MODEL NO. NOTES QTY. FAN VOLTAGE/ PHASE COOLING COIL CONDENSER FANS FILTERS MOCP ELECTRIC HEATING COIL SINGLE POINT UNIT UNIT INFORMATION -T-CAPTIVEAIRE FLA LOCATION MAU-1 KITCHIN DIRECT 900 0.5 1 HP 823 115/10 10.2 16.5 212 A1 -G10 -MPU - NOTES: VOLTS/ TOTAL ��`�llllilrrrii A No. 69124 Adam J Barney ,�Q ' , STATE OF !(� 2018.01.31 15:11:56-05'00' ioNAE ,rr�0\ This Item hes been eloctronioaily, slgned and sealed by Adam J. Barney, PE on tha Date and/or Time amp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature mut be -Mod on say electronic coplea CSC Joseph, Lawpence & Co Consullinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW,JLCENG.COM CA NO. 28730 JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 DX SPLIT CONDENSING UNIT SCHEDULE (STRAIGHT COOL) MARK LOCATION DX SPLIT AIR HANDLING UNIT SCHEDULE ELECTRICAL UNIT INFORMATION MANUFACTURER MODEL NUMBER NOTES OUTDOOR F) TEMP. QTY. CAPACITY STEPS QTY. FAN VOLTAGE/ PHASE COOLING COIL CONDENSER FANS FILTERS MOCP ELECTRIC HEATING COIL SINGLE POINT UNIT UNIT INFORMATION MARK FLA LOCATION TOTAL AIR OUTSIDE EXTERNAL STATIC DRIVE HP ENTERING LEAVING TOTAL NO. OF VOLTS/ TOTAL HEATER VOLTAGE/ SINGLE SINGLE UNIT SIZE OPERATING MANUFACTURER MODEL NUMBER MOUNTING APPLICATION NOTES 1. PROVIDE COMPLETE WITH TIME DELAY RELAY AND ANTI -SHORT CYCLE TAMER. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECT. 1. PROVIDE COMPLETE WITH POWERED CONVENIENCE OUTLET. SERVED (CFM) AI (CFLOFM)W TYPE AIR TEMP. TEMP. I) TY TYPE EFFICIENCY THICKNESS STAGES PHASE KW STEPS PHASE LMCA IT CIRCUIT (H xW xD) WEIGHT (LBS.) IPRESS. (F' DB/WB) (F'I DB/WB) (B UHR AHU-1 PUB 5,000 1 750 1 1 BELT 1 2.9 178.0/63.0152.8/52.4 1148,000 1 THROWAWAY 1 30% 1 2 1 208/3 115.0 1 1 1208/31 61.5 1 70 1 56 x49 x28' 695 CARRIER 40RUA014 HORIZONTAL 1. NOTES: 1. PROVIDE COMPLETE WITH SINGLE POINT WIRING, 1" THICK CABINET FOIL FACED INSULATION, AND 7 -DAY PROGRAMMABLE THERMOSTAT, HUMIDOSTAT WITH NIGHT SET BACK, FACTORY INSTALLED TXV KIT, AND CONDENSATE OVERFLOW SWITCH. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECT. ��`�llllilrrrii A No. 69124 Adam J Barney ,�Q ' , STATE OF !(� 2018.01.31 15:11:56-05'00' ioNAE ,rr�0\ This Item hes been eloctronioaily, slgned and sealed by Adam J. Barney, PE on tha Date and/or Time amp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature mut be -Mod on say electronic coplea CSC Joseph, Lawpence & Co Consullinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW,JLCENG.COM CA NO. 28730 JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 DX SPLIT CONDENSING UNIT SCHEDULE (STRAIGHT COOL) MARK LOCATION COMPRESSOR CONDENSER FANS ELECTRICAL UNIT INFORMATION MANUFACTURER MODEL NUMBER NOTES OUTDOOR F) TEMP. QTY. CAPACITY STEPS QTY. NOMINAL HP VOLTAGE/ PHASE COMPRESSOR EACH EAH CONDENSER FANS MCA MOCP SEER/EER UNIT SIZE (H"xW"xD") G OPERATING (LBS.) QTY. FLA CU -1 GROUND 95' 1 100 1 2 1 1/4 1 208/3 48 1 2 1.5 167.9 1 80 11 45"08"04" 650 CARRIER 38AUZ14 1., & 2. 1. PROVIDE COMPLETE WITH TIME DELAY RELAY AND ANTI -SHORT CYCLE TAMER. ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECT. 1. PROVIDE COMPLETE WITH POWERED CONVENIENCE OUTLET. ��`�llllilrrrii A No. 69124 Adam J Barney ,�Q ' , STATE OF !(� 2018.01.31 15:11:56-05'00' ioNAE ,rr�0\ This Item hes been eloctronioaily, slgned and sealed by Adam J. Barney, PE on tha Date and/or Time amp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature mut be -Mod on say electronic coplea CSC Joseph, Lawpence & Co Consullinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW,JLCENG.COM CA NO. 28730 JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 NOTE: ALL ROOF TOP EQUIPMENT AND SUPPORTS SHALL BE SECURED TO THE STRUCTURE IN COMPLIANCE WITH THE LOADING REQUIREMENTS OF CHAPTER 16 (HIGH -VELOCITY HURRICANE ZONES) OPPOSED BLADE GRAVITY DAMPER 1 25 < 36 CAULK WATER 36 < 48 24 48 < 60 30 TIGHT ALL AROUND 48 MEMBERS (-Y16" MIN HOST THICKNESS LOUVER --fir WALL r LOOP HANGING WIRE ANCHOR WITH 1"0 MIN. WASHER, ZW' 2 SIZE EQUAL TO UNIT EMBEDMENT & 6" MIN EDGE DISTANCE, 4 UPPER ATTACHMENT PER SMACNA ANCHORS PER BASE PLATE, ONE IN EACH TRUSS WEBBING CORNER 3 WOOD CABINET DIMENSIONS HORIZONTAL EXHAUST AIR FLEXIBLE DUCT 6'-0" MIN. WASHER AND LOCKING NUTS. 4 BETWEEN SUPPORT POINTS ANCHORS PER BASE PLATE, ONE IN EACH CORNER � US RIGGING / LOUVER - RUSKIN OR %"0 SAE GRADE 5 THRUBOLT WITH 1"0 MIN. 4 STEEL WASHER & NUT, TO STRUCTURAL A36 STEEL GRIPPLE M#: G -RG -04 ; MEMBERS (-g" MIN HOST THICKNESS) EQUAL j Ole, cot CO UNI BIRDSCREEN ' Ilk `'�-- WELDED AT SEAMS (TYP) 30" MIN. 1 1/2"X1 2/2"X1/8" STEEL ANGLE UMLESS (TYPICAL) OTHERWISE MOTORIZED DAMPER AT MECHANICAL U NOTED 3"X3"X1/4" STEEL PLATE FLASHING WALL EXTERIOR WALL PROVIDE ANGLES AT TOP & SIDES 3"X3"X1/4" RIDGE RUBBER OR EQUIVALENT VIBRATION (TYPICAL UNDER ALL FEET) ISOLATION PAD — (TYPICAL) NOTES: PRIME COAT AND PAINT ALL STEEL AFTER 1. PROTECT OPENING PER FLORIDA BUILDING CODE - FABRICATION MECHANICAL SECTION 401.5 AND 401.6 T 8 SIDEWALL LOUVER DEVIL 7 STEELANGLE UNIT STAND DETAIL NTS NTS (FOR ANU-1) REFER TO BELOW ANCHOR SCHEDULE SIDE TAKE -OFF FITTING - EQUAL VIBRATION -- STEEL ROD W/THREADEDTO FLEXMASTER STO (22 GA. MIN.) .ISOLATORS ENDS (TYP. 4 PLACES) MAX. 15' TRANSITION 0.25 D } SUPPORT FROM STRUCTURE -•- RECTANGULAR DUCT I ROUND DUCT BACKDRAFT ABOVE AS REQUIRED. 3 DAMPER (CORDINATE W/STIRUCT.) TO AIR LO a ¢ VALVE AIR SEE PLANS '�� � a FLOW CL FOR DUCT ,���'-`\��\ 1 FLOW VOLAIR UME DAMPER SIZES I-� 1 I SEE PLANS `n FOR DUCT SIZES CONICAL FITTING WITH LOCKING TYPE VOLUME DAMPER. DAMPER AND DAMPER STAND-OFF EQUAL TO CROWN TRANSITION AS CENTRIFUGAL FLEXIBLE CONNECTOR PRODUCTS COMPANY MODEL 3200 -DS. MIN. (2) #10 SHEET METAL SCREWS THROUGH UNIT HOUSING. MIAMI TECH CONDENSING UNIT TIE DOWN STRAP. MODEL NUMBER CUTD4 OR EQUIVALENT. k (1) 1/2" DIAMETER CARBON STEEL TAPCON EMBEDDED 1-3/4" WITH 2-1/2" MIN. PAD EDGE DISTANCE. CLEARANCE BELOW RAISED ROOF MOUNTED MECHANICAL UNITS WIDTH OF EQUIPMENT (IN) I HEIUMI OF LEGSj= < 24 1 25 < 36 18 36 < 48 24 48 < 60 30 > 60 48 ALUMINUM TELESCOPING CONDENSING UNIT STAND AS MANUFACTURED BY MIAMI TECH OR EQUIVALENT. INSTALL AND ADJUST PER MANUFACTURERS RECOMMENDATIONS. ANCHOR SCHEDULE ANCHOR TYPE H ST SIRUCTUREI ANCHOR SCRIP 10 IN SIDE OF DUCT UNLESS %"0 SAE GRADE 5 SHEET METAL SCREWS WITH 1 STEEL 1 0 MIN. WASHER, TO STRUCTURAL A36 STEEL MEMBERS (-Y16" MIN HOST THICKNESS COLLAR CONNECTION %"0 CARBON STEEL WEDGE -BOLT CONCRETE r LOOP HANGING WIRE ANCHOR WITH 1"0 MIN. WASHER, ZW' 2 CONCRETE EMBEDMENT & 6" MIN EDGE DISTANCE, 4 UPPER ATTACHMENT PER SMACNA ANCHORS PER BASE PLATE, ONE IN EACH TRUSS WEBBING CORNER 3 WOOD %"0 SAE GRADE 5 THREADED RODS WITH -" WEBBING L FLEXIBLE DUCT 6'-0" MIN. WASHER AND LOCKING NUTS. 4 BETWEEN SUPPORT POINTS ANCHORS PER BASE PLATE, ONE IN EACH CORNER � US RIGGING / MAXIMUM LENGTH %"0 SAE GRADE 5 THRUBOLT WITH 1"0 MIN. 4 STEEL WASHER & NUT, TO STRUCTURAL A36 STEEL GRIPPLE M#: G -RG -04 ; MEMBERS (-g" MIN HOST THICKNESS) REQUIRED EXHAUST FAN TYPICAL OF SUPPLY AND CEILING DISCHARGE SIDES. FLEX DUCT OR ROUND SHEET METAL DUCT. FLEX ....w DUCT MAX. 8'-0" LONG, USE CLAMP TO ATTACH FLEX DUCTS AND ,SEAL AS PER SPECIFICATIQNS, L�a CONDENSER F�0 O F RACK DETAIL a SUPPORT FLEX DUCT EVERY 3'-0" FROM STRUCTURE. NTS a 6 INLINE CABINET FAN DETAIL DUCT CONNECTION DETAIL NTS MAIN DUCT -1 i SEAL INSULATION JOINTS AND DRAWBAND ON OUTSIDE OF BREAKS IN VAPOR BARRIER INSULATION AROUND JACKET WITH GLASS FABRIC AND MASTIC (NO TAPE ALLOWED) DRAWBAND ON FLEXIBLE DUCT (INNER SLEEVE) INSULATION AND JACKET FLEXIBLE DUCT 103 MAXIMUM D/8 OFFSET i OR EQUAL / / NON I BUTTERFLY DAMPER WITH ALLOWED IN LAST D INCHES �" GRADE 304 LOCKING QUADRANT OPERATOR TO DEVICE WHERE D IS THE SPIRAL DUCT STAINLESS STEEL CABLE BELLMOUTH FITTING WATER BASE DUCT SEALER INTERNAL FLEX DIAMETER SEE NOTE 3 BETWEEN FLEXIBLE DUCT AND VOLUME DAMPER WITH LOCKING SUPPORTING DUCT ADJUSTABLE CLAMP STAINLESS STEEL QUADRANT AND 2" STANDOFF INSULATION AS SPECIFIE SHEETMETAL DUCT (APPLY SEALER TO BOTH SHEETMETAL AND INSIDE NECK SIZE TO MATCH DUCT SEALER OF FLEX PRIOR TO ASSEMBLY) FLEX DUCT SIZE INDICATED INSULATE TOP PANEL OF LAY -IN DIFFUSER OVERLAP FULL DISTANCE OF NECK NOTES: N DUCT MOUNTED f DIFFUSER. SEE AIR 1. TYPICAL FOR: LOW PRESSURE AND HIGH PRESSURE CONNECTION V DEVICE SCHEDULE. TO MAIN DUCT, FAN TERMINAL UNITS, VARIABLE AIR VOLUME UNITS, CEILING (T -BAR SHOWNT AIR DISTRIBUTION DEVICE, SEE PROVIDE CEILING ACCESS AND DIFFUSERS. GYPSUM BOARD SIMILAR SCHEDULE. LAY -IN SHOWN PANEL FOR DAMPER ACCESS 2. DRAWBANDS SHALL BE EQUIVALENT TO PANDUIT PLT -H. SURFACE MOUNT SIMILAR IN NON -ACCESSIBLE CEILINGS NOTES.: 1. FLEXIBLE DUCTS SHALL BE ONE-PIECE AND SHALL NOT BE SPLICED TOGETHER. NOTES 2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND 1. MAXIMUM SPACING BETWEEN HANGER LOCATIONS SHALL SEAL WITH MASTIC. BE 8'-0" PER PAIR. 1 FLEXIBLE DUCT CONNECTION DETAIL 3. MINIMUM 1-1/2" WIDE 22 GAUGE GALVANIZED STRAP HANGER WITH HEMMED EDGES PER SMACNA FIGURE 3-10. 2. REFER TO SMACNA FOR ADDITIONAL REQUIREMENTS. NTS 4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW RADIUS NO LESS THAN R/D=1.0. 3. ALL SPIRAL DUCT TO BE 1" DOUBLE WALL INSULATED SPIRAL DUCTWORK 3 FLEXIBLE DUCT DETAIL (___2 SPIRAL DUCTWORK SUPPORT DETAIL- NTS DATE, 8/V4011 SEAL (�C Josepk, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL 321.972.4466 WWW.JLCEHG.COM CA NO. 28730 .................._....JLC 17.025$.00._._._....... No, 69124 a Adam J Barney �(Q� ; STATE OF �44j ' 2018.01.31 15:12:20-05'00' /0NA1_ '�r�llllll��` This Rem has been eleclrdnlcally signed and sealed by Adam Joseph Barney Adam J. Barney, PE oa the Data and/or TimeStamp shown uaa® a dlghal eighatare Pdntad copies of I],,. document are P.E. #: 69124 not coneMarad signed and sealed and the eIgnstore mull be verified on any electronic corloe ^^.^^^-^^^^^ ^^^^•^-^^-^^• ROUND SPIN -IN COLLAR MOUNT IN SIDE OF DUCT UNLESS DUCT SEALER AT SPIN / SPECIFICALLY SHOWN OTHERWISE COLLAR CONNECTION -i r LOOP HANGING WIRE ADJUSTABLE CLAMP TO MAIN STRUCTURE THROUGH TRUSS UPPER ATTACHMENT PER SMACNA SUPPLY DUCT SIZE AS TRUSS WEBBING MAX. SAG Y2" PER FOOT SHOWN ON PLANS WEBBING L FLEXIBLE DUCT 6'-0" BETWEEN SUPPORT POINTS � US RIGGING / MAXIMUM LENGTH 0 GRIPPLE M#: G -RG -04 ; SEAL INSULATION JOINTS AND DRAWBAND ON OUTSIDE OF BREAKS IN VAPOR BARRIER INSULATION AROUND JACKET WITH GLASS FABRIC AND MASTIC (NO TAPE ALLOWED) DRAWBAND ON FLEXIBLE DUCT (INNER SLEEVE) INSULATION AND JACKET FLEXIBLE DUCT 103 MAXIMUM D/8 OFFSET i OR EQUAL / / NON I BUTTERFLY DAMPER WITH ALLOWED IN LAST D INCHES �" GRADE 304 LOCKING QUADRANT OPERATOR TO DEVICE WHERE D IS THE SPIRAL DUCT STAINLESS STEEL CABLE BELLMOUTH FITTING WATER BASE DUCT SEALER INTERNAL FLEX DIAMETER SEE NOTE 3 BETWEEN FLEXIBLE DUCT AND VOLUME DAMPER WITH LOCKING SUPPORTING DUCT ADJUSTABLE CLAMP STAINLESS STEEL QUADRANT AND 2" STANDOFF INSULATION AS SPECIFIE SHEETMETAL DUCT (APPLY SEALER TO BOTH SHEETMETAL AND INSIDE NECK SIZE TO MATCH DUCT SEALER OF FLEX PRIOR TO ASSEMBLY) FLEX DUCT SIZE INDICATED INSULATE TOP PANEL OF LAY -IN DIFFUSER OVERLAP FULL DISTANCE OF NECK NOTES: N DUCT MOUNTED f DIFFUSER. SEE AIR 1. TYPICAL FOR: LOW PRESSURE AND HIGH PRESSURE CONNECTION V DEVICE SCHEDULE. TO MAIN DUCT, FAN TERMINAL UNITS, VARIABLE AIR VOLUME UNITS, CEILING (T -BAR SHOWNT AIR DISTRIBUTION DEVICE, SEE PROVIDE CEILING ACCESS AND DIFFUSERS. GYPSUM BOARD SIMILAR SCHEDULE. LAY -IN SHOWN PANEL FOR DAMPER ACCESS 2. DRAWBANDS SHALL BE EQUIVALENT TO PANDUIT PLT -H. SURFACE MOUNT SIMILAR IN NON -ACCESSIBLE CEILINGS NOTES.: 1. FLEXIBLE DUCTS SHALL BE ONE-PIECE AND SHALL NOT BE SPLICED TOGETHER. NOTES 2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND 1. MAXIMUM SPACING BETWEEN HANGER LOCATIONS SHALL SEAL WITH MASTIC. BE 8'-0" PER PAIR. 1 FLEXIBLE DUCT CONNECTION DETAIL 3. MINIMUM 1-1/2" WIDE 22 GAUGE GALVANIZED STRAP HANGER WITH HEMMED EDGES PER SMACNA FIGURE 3-10. 2. REFER TO SMACNA FOR ADDITIONAL REQUIREMENTS. NTS 4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW RADIUS NO LESS THAN R/D=1.0. 3. ALL SPIRAL DUCT TO BE 1" DOUBLE WALL INSULATED SPIRAL DUCTWORK 3 FLEXIBLE DUCT DETAIL (___2 SPIRAL DUCTWORK SUPPORT DETAIL- NTS DATE, 8/V4011 SEAL (�C Josepk, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL 321.972.4466 WWW.JLCEHG.COM CA NO. 28730 .................._....JLC 17.025$.00._._._....... No, 69124 a Adam J Barney �(Q� ; STATE OF �44j ' 2018.01.31 15:12:20-05'00' /0NA1_ '�r�llllll��` This Rem has been eleclrdnlcally signed and sealed by Adam Joseph Barney Adam J. Barney, PE oa the Data and/or TimeStamp shown uaa® a dlghal eighatare Pdntad copies of I],,. document are P.E. #: 69124 not coneMarad signed and sealed and the eIgnstore mull be verified on any electronic corloe ^^.^^^-^^^^^ ^^^^•^-^^-^^• SUPPI. 0 12" LONG TRANSITION AS REQUIRED - NO OUTSIDE AIR DUCT -- INSTALL PIPING, CONDUITS, AND DUCTWORK TO ALLOW SPACE FOR REMOVAL OF FILTERS AND SERVICING OF UNIT. MOTORIZED DAMPER' NOTE: DRAIN PAN: MINIMUM 2" DEEP AND NOT LESS THAN 3" LARGER THAN UNIT OR COIL DIMENSIONS IN WIDTH AND LENGTH -~ 1` 3/4" CONDENSATE DRAIN ROUTE IR I TO DRYWELL. SEE HVAC PLAN FOR RNA LOCATION. _ SUCTION LINE AND LIQUID LINE CONNECT TO CONDENSING UNIT. 3/4" AUXILIARY DRAIN PAN DRAIN:—//AUXILIARY DRAIN PAN WITH FLOAT SWITCH TO SHUT 2" NEOPRENE DOWN UNIT. ISOLATION PAD HB DRAIN 4 HORIZONTAL AHU DETAIL NTS - Thermal Ceramics . r (` Box r,)23 3 IN. `�I� (76 MM) a�l���� .�t,,, (e >raln MIN. PERIMETER `` ,N 1 nll C:.: � (1{j) c.�nll—/I'. (; .in OVERLAP ON OUTSIDE LAYER - `N, IN . ` I ` 1,,1 ,`.�,`, , `l 1 111�� 2 x 2 x 1/8 IN. MIN. 'IN 000l� ANGLE 1/2 IN. (13 MM) MIN. CARBON OR STAINLESS STEEL BANDING �1� 1 0.015 IN. MIN. THICKNESS TYPICAL — PLACED AT 10-1/2 IN. SPACING AND CENTERED OVER OVERLAPS Note: Label Required 3 IN. (76 MM) 'AccessDoor" MIN. 1 Do Not Obstruct LONGITUDINAL OVERLAP ON OUTSI E LAYER TIGHT FIREMASTER F2—HT—XL3 DOOR SYSTEM COMPRESSION JOINT ON INSIDE LAYER 1. THERMAL CERAMICS FIREMASTER FASTWRAP XL OR PYROSCAT XL HAS BEEN TESTED IN ACCORDANCE WITH ASTM E2336 TO PROVIDE ZERO CLEARANCE TO COMBUSTIBLES AND MEETS THE REQUIREMENTS FOR ONE OR TWO HOUR ENCLOSURES. THROUGH PENETRATIONS FIRESTOP SYSTEMS ARE TESTED IN ACCORDANCE WITH EITHER ASTM E 814 OR UL 1479. ICC—ES APPROVAL PER REPORT ESR 2213 OR ESR 2832. UNDERWRITER'S LABORATORIES (UL) LISTINGS SHOW COMPLIANCE TO UL 1479 FOR THROUGH PENETRATION FIRESTOP SYSTEMS. 2. INSULATION APPLIED IN TWO LAYERS WITH TIGHT COMPRESSION JOINT ON INSIDE LAYER AND 3 INCH MINIMUM OVERLAPS ON BOTH PERIMETER AND LONGITUDINAL OVERLAPS ON OUTSIDE LAYER. 3. GREASE EXHAUST DUCT RUNS FROM THE HOOD EXHAUST CONNECTION UP TO THE EXHAUST FAN ON THE ROOF WITH MINIMAL TURNS OR BENDS AND MAINTAINING MINIMUM 1" UNIT VERTICAL RISE PER 12 UNITS HORIZONTAL RUN. NFPA 96 COMPLIANT ACCESS DOORS LOCATED AS REQUIRED BY CODE. 4. THERMAL CERAMICS FIREMASTER ACCESS DOORS AS SPECIFIED IN ICC -ES BUILDING CODE REPORTS ESR 2213 OR ESR 2832. 5. ROOF MOUNTED EXHAUST FAN IS MOUNTED ON A HINGED BASE WHICH ALLOWS ACCESS TO THE DUCT FROM THE ROOF. 6. SUPPORT HANGER SYSTEMS DO NOT NEED TO BE WRAPPED PROVIDED THE HANGER RODS ARE AT LEAST A MINIMUM OF 3/8 IN. DIAMETER. USE MINIMUM 2 X 2 X 1/8 IN. STEEL ANGLE OR SMACNA EQUIVALENT SUPPORT SYSTEM. 7. THERMAL CERAMICS DUCT ENCLOSURE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 8. THERMAL CERAMICS DUCT WRAP SHALL BE INSTALLED ON THE DUCT FROM THE HOOD CONNECTION TO THE CONNECTION TO THE FAN. (`-2 GREASE EXHAUST DUCT PROTECTION NTS TO COMBUSTIBLES DETAIL FLEXIBLE CONNECTIeN EXISTING DECK AND INSULATION EF (WITH PHENOLIC COATING WEATHER PROOF ENCLOSURE NCOPRENC ISOLATORS FLASH AND ROOF IN SUPPORT ---- RESSURE TR TED 08 SUPPORT TO SPAN EXIS ING JOISTS 3 EXHAUST FAN INSTALLATION DETAIL NTS 16GA. WELDED EXHAUST GREASE DUCT (TYP.) U.L. LISTED ACCESS PANEL THERMAL CERAMICS FIREMASTER FASTWRAP XL OR EQUAL. SEE DETAIL REMOVABLE GREASE FILTER W/ HANDLES AUTO FIRE EXTINGUISHER (SEPARATE PERMIT BY FIRE EXTINGUISHER CO.) MTL. WALL FLASHING 24 GA. S/S SHEET MTL 6" TYP. 0 ALL OPEN SIDES --- 0 FIN. NOTE: CONTRACTOR TO FIELD VERIFY EXACT ROUTING WITH STRUCTURE PRIOR TO FABRICATION (TYP) PROTECT OUTDOOR DUCTS AGAINST CORROSION \ r 5/8" TYPE "X" GYP. BD. ALL AROUND DUCT (FIRE RATED SHAFT PER BLDG CODE) IF REQUIRED 5" �- 3" MIN. 3" MIN. --I COOKING EQUIPMENT BY OTHERS GREASE HOOD SECTION 20 STUD WALL W/ 5/8" TYPE "X" GYP. -BD. ON BOTH SIDE CX Joseph, Lawpe9nce & Co 00-01, ConsultingEn ineees 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG.COM CA NO. 28730 jl fill �\l i BA)t; 'V JLC 17.0258.00 No. 69124 Adam J Barney 0 STATE of wW` 2018.01.31 15:12:56-05'00' This Item has been electronically signed and healed by Adam Joseph Barney Adam J, Barney, PE on the Data andlor Time Stamp shown using a digital eignatura. Printed copies of this documentary P.E. #: 69124 nat oom ldyred signed and sealed and the signature —9t be verlgyd on any elaclronic wplas ^.._.m ^^•^ -•� -� � ■ i f HOOD INFORMATION — Job 3257152 t unnn TATFnI?JL A TTnN FILTERCS> LIGHT(S) MAX, EXHAUST PLENUM TOTAL HOOD HOOD CONFIG.. TOTAL RISERS) END TO ROW HOOD NO, TAG MODEL LENGTH COOKING SUPPLY HOOD CONSTRUCTION ELECTRICAL SWITCHES SYSTEM HANGING TYPE SIZE MODEL # QUANTITY NO, TYPE TEMP, EXH. CFM WIDTH LENG, HEIGHT DIA, CFM VEL, S.P. CFM WGHT END SS Baffle with Handles 4 2630 16' 400 0 430 SS 203 LBS 2 1 BL 61 0" Deg, 1200 0 4" 10" 1200 2200 -0,567" 0 Where Exposed ALONE ALONE 146 300 430 SS 2 MTSC-PSP 6' 0" Deg 0 900 Where Exposed ALONE ALONE. t unnn TATFnI?JL A TTnN -% 6# 010" d 6' 0"Nom,/6' 0.50"OD PLAN VIEW Hood #1 ' 0.00 LONG 2830 B L J-z.M 14 " g" ----------------- rf------- ------ �" " 0 2 " --- 18 1/4" 35 1/2" 6' 0"Nora,/6' 0,00"QD PLAN VIEW — Hood 2 6' ,QCT" LONG 146MISC—PSP BUILT IN ACCBH R NF'PA .,wrww+s.wwswr. Na 0u 96 s Ont Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG.COM CA NO. 28730 JLC 17.0258.00 \,\CENSE' No. 69124 -p Adam J Barney �0 ' srarE OF w� 2018.01.31 15:13:35-05'00' /ONAL This dem has been 9lormonioaliy signed and sealed by I Adam Joseph. Barney Adam J. Samey, PE on the Date andmi,'Time Stamp shovm using a digital signatum. Printed copies of this documam are P.E. #: 69124 not considered signed and settled and the signature mud be verified on any slootmic copies ...,m.„�.-m...,.m-•------------._ > FILTERCS> LIGHT(S) UTILITY CABINETCS) FIRE HOOD HOOD TAG EFFICIENCY � 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES SYSTEM HANGING TYPE SIZE MODEL # QUANTITY NO, TYPE QTY, HEIGHT LENGTH MICRONS QTY, TYPE GUARD LOCATION SIZE PIPING WGHT 1 SS Baffle with Handles 4 16" 16' 30% 0 YES 203 LBS 2 0 NO 50 LBS -% 6# 010" d 6' 0"Nom,/6' 0.50"OD PLAN VIEW Hood #1 ' 0.00 LONG 2830 B L J-z.M 14 " g" ----------------- rf------- ------ �" " 0 2 " --- 18 1/4" 35 1/2" 6' 0"Nora,/6' 0,00"QD PLAN VIEW — Hood 2 6' ,QCT" LONG 146MISC—PSP BUILT IN ACCBH R NF'PA .,wrww+s.wwswr. Na 0u 96 s Ont Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG.COM CA NO. 28730 JLC 17.0258.00 \,\CENSE' No. 69124 -p Adam J Barney �0 ' srarE OF w� 2018.01.31 15:13:35-05'00' /ONAL This dem has been 9lormonioaliy signed and sealed by I Adam Joseph. Barney Adam J. Samey, PE on the Date andmi,'Time Stamp shovm using a digital signatum. Printed copies of this documam are P.E. #: 69124 not considered signed and settled and the signature mud be verified on any slootmic copies ...,m.„�.-m...,.m-•------------._ > EXHAUST RISER HANGING ANGLE 16" SS BAFFLE WITH HANDLES AND HOOK IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS .IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS, CREASE DRAIN WITH REMOVABLE CUP —ATTACHING PLATES 2'75" SUPPLY RISER WITH VOLUME DAMPER _ 6" 14" 23a5:! OPEN STAINLESS STEEL PERFORATED PANEL FIELD WRAPPER 18,00" HIGH (SEE HOOD OPTIONS TABLE) i ' NOM, SECTION VIEW -MODEL 2830BL HOOD - It' 14 1 Joseph, Lawrence & Co Consultinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCING.COM CA NO. 28730 BAR '�,,� JLC 17.0258.00 No. 69124 Adam J Barney Q '•, STATE OF Z(/�, 2018.01.31 15:13:58-05'00' CG /`'//,!QNA� 00� ThinRam 1,.nWan alaceonicaiiy aign,d and aeWnd by Adam Samay. PE on the Dale andlor Timo Stamp shown Adam Joseph Barney umng a digital Wgnaturo. Pnmed odea of mie document ars not consldemd signed and saelad and the Wgnaturo mud be P.E. #: 69124 ; , y ftd on any Wecmonk copies F N 4.1 DQa5HFA - X T FAN 23" l'X11Y 11 Ml' V1 U.4Y117A l{.I1V [r vv VENTED FEATURES, CURB - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS) FAN UNIT TAG 31 7/ _ ROOF MOUNTED FANS 26 ESP, RPM H',P, -RESTAURANT M'C1llCL 0 VOLT FLA DISCHARGE VELOCITY WEIGHT (LBSr) SINES - UL705 AND UL762 20 GAUGE - VARIABLE SPEED CONTROL STEEL - INTERNAL WIRING '~�-Y, CONSTRUCTION - WEATHERPROOF DISCONNECT 1 THERMAL OVERLOAD PROTECTION (SINGLE PHASE) DU85HFA 1200 1,500 1347 0.750 0,4330 1 115 HIGH HEAT OPERATION 300'F (149°C) � �-� � 3'a FLANGE o a - GREASE CLASSIFICATION TESTING / - o 30 1/2 NORMA T .._M�. P_PERATURE TEST / EXHAUST FAN MUST OPERATE CONTINUOUSLY ROOF GPENING 23 WHILE EXHAUSTING AIR AT 300°F 0149*(} 22 1/2 DIMENSIONSUNTIL ALL FAN PARTS HAVE REACHED / 22 1/2 -/ THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH GREASE DRAIN WOULD CAUSE. UNSAFEOPERATION. ,� PITCHED CURBS ARE AVAILABLE 0" 8 EXHAUST FAN MUST OPERATE CONTINUOUSLY FOR PITCHED RO[]F& WHILE EXHAUSTING BURNING GREASE 'VAPORS 00 14 7/8---- ( AT 600•F 0316°C) FOR A PERIOD OF SPECIFY PITCHI 12' f 15 MINUTES WITHOUT THE FAN BECOMING EXAMPLEx 7/12 PITCH = 30° SLOPE DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION; �----- 22 1/2 OPTIONS 24 /4 -w GREASE BOX ECM WIRING PACKAGE -EXHAUST --w MANUAL OR 0-10VDC REFERENCE SPEED CONTROL (NIDE( MOTOR) DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) r"wtrrrArrt•rrn "Air rAr"/Ar"D2J`AM7'/1AT T'..111100icr'Y4i"0 lidllIAft L/IJ 1 l'X11Y 11 Ml' V1 U.4Y117A l{.I1V [r vv vrvv r I Wnr FAN UNIT TAG FAN UNIT MODEL # CFM ESP, RPM H',P, B,HrP, 0 VOLT FLA DISCHARGE VELOCITY WEIGHT (LBSr) SINES NO. 1 DU85HFA 1200 1,500 1347 0.750 0,4330 1 115 8.8 380 FPM 92 15.4 CSC Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE„ SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG.COM CA NO. 28730 0 \\1111111//,� PM BqRAl M..Mw...._.- 17.0258.00 No. 69124 -p Adam J Barney 4u 2018.01.3115:14:17-05'00' C7 STATE OF I ONAL \E This Item hes been electronically signed and seated by Adam J. Barney, PE on the Date mcit., Time Stamp showm Adam Joseph Barney using a digital signature. Printed copies of this document are �{ 69124 not eonsidered signed and sealed and the signature must be P.E. $: 61 24 verified on any electronic copias A_K.VVVZSJ 14 701 WEST Third Street, So pATEs anr�ml7 SEAL FAN #2 Al-GIOD - SUPPLY FAN 1, DIRECT DRIVE DIRECT DRIVE UNTEMPERED SUPPLY UNIT WITH 10" BLOWER IN SIZE #1 HOUSING WITH SPEED CONTROL, DISCONNECT SWITCH, 2, INTAKE HOOD WITH EZ FILTERS 3, DOWN DISCHARGE - AIR FLOW RIGHT > LEFT 44, ECM WIRING PACKAGE AND MANUAL OR 0-10`✓DC CONTROL FOR SUPPLY EC MOTORS. RTC CONTROLLER, N❑TEi SUPPLY DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS, A MINIMUM STRAIGHT DUCT LENGTH EQUAL TO THREE TIMES THE SUPPLY DUCT EQUIVALENT DIAMETER MUST BE MAINTAINED DOWNSTREAM OF UNIT DISCHARGE UNLESS OTHERWISE SPECIFIED, DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY, BLOWER DISCHARGE CURB 1 3/4' -1 oa� 13 1/4 3 7/8" I ut's t J,.Lt—a WIRING LIFTING LUG AIRFLOW SERVICE AIRFLOW DISCONNECT 29 3/4" SWITCH BLOWER/MOTOR ACCESS DOOR 24' SERVICE oo L 'CLEAR ANCE 4 + 4 3 3/4" 4 10 1/4" T- 14#EQUIPMENT CURB ��- 21" --- 21" --= ROOF OPENING 2" SMALLER THAN CURB DIMENSION, PITCHED CURBS ARE AVAILABLt 0^ AN I1"�i'C�F,'MA7"I1N ~- Job,25'15,2 FOR PITCHED ROOFS, 0 SPECIFY PITCHI 12" EXAMPLEI 7/1.2 PITCH = 30' SLOPE Al ' FAN UNIT MODEL # BLOWER HOUSING DESIGN CFM ESP, RPM H,P, B,H,P, �s VOLT FLA WEIGHT WEIGHT SONES FAN UNIT NO, TAG MIN MAX 2 A1—G10 G10D Al 0 900 0,500 823 1,000 0,4250 1 115 10.2 212 1 5 Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCENG.COM CA NO. 28730 111111111// _ ...._ J Bq�iiyJLC 17.0258.00 ` �;�: LICENSE •: F�, Z_ No. 69124 Adam J Barney =gyp STATE QE ` !(�\ 2018.01.31 15:14:53-05'00' •• !DGORIDP.•����ti Thla Item has been olacVonicslly signori end sealed by Adam Joseph Barney Adem J. no PE PE on the Data and/or Time Stamp shown ,/{ �+ using a digital algnatura. Pdoled copies of lhis document are P.E. #: 69124 not considered signed and &*sled and the signature must be verified oa any electronic ooples L7C Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321,972.4466 WWW.JLCENG.COM CA NO. 28730 1y11lIIII// -. [3q .__.._.__..._JLC 17.0258.00 M... B R OP' �I0ENSF'NF,( Q'r r No. 69124 _ �a' � Adam J Barney �Q STATEOF ((/� 2018.01.31 15:15:16-05'00' i� F40RIOP.•` �N ssIONAL Er� (/11111I This It— has been electronlcally signed and sealed by Adam Joseph Barney Adam J. Barney, PE on the Dale andlor Time Stamp shown using a digital signature. Printed copies of this document are P.E. #: 69124 not considered signed and sealed and the signature must be verified on any electronic copies ...........,............,,.....,. ...,......„.,,.._.,.._.._._. DRAYN 8Y S�aAPC TYPE DESCRIPTION OF OPERATIONI JCB NO MODEL NUMBER� /� pr SC 1111141F!'" FANS CONTROLLED NO. TAG PACKAGE # LOCATION INSTALL OPTION 120V 1 Phase wJ control for I Exhaust F'an, 1 Supipty Fan, Exhaust on In Fire, Lights out In Fire, Fon(s) On/Off QUANTITY TYPE 7 3257152 JCB NAME FLA DATE DWO NO rhermoataticatly Controlted, Room temperature sensor shipped toose For Field instatlation, wAft Pw 05 - SS .Wall 1J2✓2018 ECP #1•-1 Exhaust 1 0,750 1 8,81 SC-111110FP Wall Mount In SS Box Mount Box BMS SWITCH BREAKER PANEL TO PRIMARY CONTROL PANEL CONTROL PANEL TO ACCESSORY ITEMS ..... _ CONTROL PANEL.:.. � __ � � � � ......_ M._, _.. � �y 'N�� µ_ R4s nspttltlt r Elcrtcialn Res ranNaltt, Elecrlclatn Supply TO-... ,,..., ...,..._,..... m.m ..... ,,......a 115 10,2 BREAKER SIZE SHOWN' IS THE MIA XII ALLOWED CONTL PANNI» �� � C�1"1Pf11V�NT_ EXTERNAL IWRNAL SIGNAL SWITCH THROUGH HMS WILL ACTIVATE' ZONE1 FANS AND Rl�A,K,._..��. PRIMA .,��L��A?:...ANEL' SWITCH LIGHTS MICROSWITCH t BREAKER 1P'Hy -"Pt- -- CONTROL PANEL 4rPl0 5?rNC _.......,.........�..,�.,.,� . .....,... � .�,... _�.._.,, .120 V - - - - - - - - - - - - - --Pteutrat_ --.:..:__ ----------_. Grr�Lta _ _ �� TO � .�. ,_...� ...., .�„.,........:.�..._................ ,... FIRE SYSTEM 1rC�..� � 15 A CONTROL POWER. D❑ NOT WIRE MICROSWITCH - TO SHUNT TRIP BREAKER WIRE ARI TO NORMALLY CLOSED (2). C1 TCI ARI SHOULD HAVE MS -1 4,NO g HOOD LIGHT BREAKER SHARED Wf IST HOO CONTINUITY WHEN ARMED, lr rN_ CONTROL POWER, SWITCH Nl cl----.-_.------ IF MORE THAN ONE FIRE SYSTEM, WIRE MS- rN l 7 BREAKER 1P'H_ 115 V - IN SERIES AS SHOWN L 0 -- MCAr 11.0 A. EXH-]---------- m..__ g MOCPr 15 A 9 BREAKER 1P'Hat ',_ CONTROC tlPANEL ALL SWITCHES FACTORY WIRED TO.,..,,.... CAT -5 CIINNECTICiN �: 115 V - _ - - - --- -6rs>und '_ SWITCHES MCAr 12th A S� UP -2 �..� , 10 MOCPr 20 A HOOD LIGHTS 1 CONTROL PANEL ,BLACKCK m .. ... WHITE TO _. __ 11 HOOD LIGHTS... ..CEN ........ ..............:I 1.400 W MAX WIRE TO J -BOX ON TOP OF HOOD 12 CONTROL PANEL TO FANS .... cni�irR��:ul>�r��L{ -_ _ _ _ _ _ _ _ _ _ _ _ _ - — -+� ResponsIbRityr Etectrlclan TO µ _ .,_ 6... - 91RE M CONTRtIU-MA0.11 PALL- ROOM TEMP 13 PRIMARY PANEL. �) �}��� KITCHEN TEMP SENSOR IN ROOM AWAY FROM HEAT SENSOR SOURCES, DO NOT INSTALL SENSOR Lead Wlrin _ FAN/ 01 ! t1P1 _...,,.wcr� EXH-1 q RLMB& ON THE CEILING GRID, SEE MANUAL. 14 C-1 Sig a LMj9A4- NA M730 v CONTROL PANEL ��.. WIRE DIRECT' � ..... - G��..........._...w.. - � ._ � �. � I k TO _ 15 TO STARTER WIRE TO DISCONNECT CAPTURE VOLUME SENSOR MOUNTEDLIN HOOD CAPTURE CAPTURE i SENSOR VOLUME/ 16 Load Wlrlrl ■FAN, 02 - SUP -2 LA.1a2 Hpt Latin THE F'MLAWING CMCTMS C_2 '- T - - - - wr iti r� vtl Tr ll v MAY LIR MAY NIT BE ... ..._ -1-- ..... terra � � t REQUIRED BASED ON JUBSI'TE 17 WIRE DIRECT WIRE TO FACTORY SPECIF`ICAT�'+IS TO STARTER PROVIDED CONDUIT DROP HOT TO SHUNT COIL CONTROL PANEL 1SI SHUN COIL 18 SIGNAL FOR DR.NfITRA F RCIMHUNI COQ ,,. _,.. ., EXTERNAL ST TERMINAL IS ENERGIZED SHUNT TRIP IN FIRE CONDITION, 19 CCINTRE:i;ANEL ° r , __ - - _. - _., _. - - - 9pMM,QN 20 SPARE FIRE ��� . � .__ _ ..� .�. ,� � NORMALLY„ OP..E.N._. _... _.. WILL SYSTEM DRY AR2RWHENN SYSTEM ARMED. HEYO CONTACT ARE USED TO DISABLE EQUIPMENT 21 _ _ .. BUIPROVIDED REIALARM WHICH MUST BE WIRED DIRECTLY TO THE ANSUL ALARM INITIATING SWITCH LOCATED IN ANSUL AUTOMAN 22 23 24 ELECTRICAL GL's' o 2 715,E L7C Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321,972.4466 WWW.JLCENG.COM CA NO. 28730 1y11lIIII// -. [3q .__.._.__..._JLC 17.0258.00 M... B R OP' �I0ENSF'NF,( Q'r r No. 69124 _ �a' � Adam J Barney �Q STATEOF ((/� 2018.01.31 15:15:16-05'00' i� F40RIOP.•` �N ssIONAL Er� (/11111I This It— has been electronlcally signed and sealed by Adam Joseph Barney Adam J. Barney, PE on the Dale andlor Time Stamp shown using a digital signature. Printed copies of this document are P.E. #: 69124 not considered signed and sealed and the signature must be verified on any electronic copies ...........,............,,.....,. ...,......„.,,.._.,.._.._._. SWITCHES FANS CONTROLLED NO. TAG PACKAGE # LOCATION OPTION LOCATION QUANTITY TYPE 7 H.P, VOLT FLA 05 - SS .Wall 1 Light Exhaust 1 0,750 115 8,81 SC-111110FP Wall Mount In SS Box Mount Box mart Controls Thermostatic Control 1 Fan Supply 1 1,000 115 10,2 L7C Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321,972.4466 WWW.JLCENG.COM CA NO. 28730 1y11lIIII// -. [3q .__.._.__..._JLC 17.0258.00 M... B R OP' �I0ENSF'NF,( Q'r r No. 69124 _ �a' � Adam J Barney �Q STATEOF ((/� 2018.01.31 15:15:16-05'00' i� F40RIOP.•` �N ssIONAL Er� (/11111I This It— has been electronlcally signed and sealed by Adam Joseph Barney Adam J. Barney, PE on the Dale andlor Time Stamp shown using a digital signature. Printed copies of this document are P.E. #: 69124 not considered signed and sealed and the signature must be verified on any electronic copies ...........,............,,.....,. ...,......„.,,.._.,.._.._._. SYSTEM CONTROL AUTLiI t"f. WITH AGENT TANK ENCLOSED 1 MANUHL. PULL STATION i CSC Joseph, Lawipence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972,4466 WWW.JLCENG.COM CA NO. 28730 J g,qR JLC 17.0258.00 r No. 69124 * Ir _ Adam J Barney p0 srar o wW 2018.01.31 15:15:36-05'00' IONA4 E 111j \ This Ilam has been electronically signed Adam Joseph Barney and sealed by �1 Adam J, Barney. PE on the Date and/or Time Stamp shown P.E.#: 69124 91 2Y using a digital signature, Printed copies of this document are r C YF V a7 not considered signed and sealed and the signature mudt by verified on onw electronic copies "" "..,.,w,..... MECHANICAL SPECIFICATIONS ELDED GENERAL 2.1 1 CABINET PIPING ROUTED ALONG BUILDING EXTERIOR WALL SHALL BE PROTECTED BY SHEET METAL HOUSING SECURELY ATTACHED TO WALL AT 8'-0" INTERVALS AND TESTING: ADJUST THE AIR CONDITIONING SYSTEMS, VENTILATING SYSTEMS, FANS, ETC., TO DELIVER NOT LESS THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK SPECIFIED IN THIS SECTION. B. CONSTRUCTION: SINGLE WALL. EXTERIOR CASING: GALVANIZED STEEL WITH BAKED -ENAMEL PAINT FINISH WITH LIFTING LUGS AND PAINTED TO MATCH BUILDING EXTERIOR. KNOCKOUTS FOR ELECTRICAL AND PIPING CONNECTIONS. TRAP OIL IN SUCTION LINE AT EVAPORATOR COIL. NO OTHER COIL TRAPS PERMITTED. PROVIDE SUCTION RISERS, CHECK VALVES, SOLENOID VALVES, OR ALL EXHAUST FANS SHALL COME WITH INTEGRAL BACKDRAFT DAMPER. SCOPE OF WORK OVERLOAD. MOUNTED ON SOLID -STEEL SHAFT WITH SELF -ALIGNING, PERMANENTLY LUBRICATED BALL BEARINGS. OTHER DEVICES REQUIRED IN PIPING SYSTEM BY MANUFACTURER'S INSTALLATION INSTRUCTIONS. TO THE OWNER 2.2 INTERIOR CASING - GALVANIZED STEEL CONTRACTOR SHALL PROVIDE THREE 3 COPIES OF A TEST AND BALANCE REPORT THIS CONT O FURNISH AND INSTALL COMPLETE AIR CONDITIONING SYSTEMS AS INDICATED ON THE DESIGN DRAWINGS WINDOW, DOOR OR FRESH AIR INTAKE. SPECIFICATIONS - MECHANICAL AT TIME OF SUBSTANTIAL COMPLETION INSPECTION. D. MOUNTING: .FAN WHEEL, MOTOR, AND DRIVES SHALL BE MOUNTED IN FAN CASING WITH SPRING ISOLATORS. AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE UNITS, EXHAUST FANS, AIR A. BASE RAILS: GALVANIZED -STEEL RAILS FOR MOUNTING ON ROOF CURB. DOORS: HINGED ACCESS DOORS WITH NEOPRENE GASKETS. PIPE HANGERS AND SUPPORTS: PIPE HANGERS, WHERE NEEDED, SHALL BE GRINNEL #260 CLEVIS TYPE, 5'-0" ON CENTER, SECURELY ATTACHED TO BUILDING CONSTRUCTION. SPACE AT MIN. AIR DISTRIBUTION EQUIPMENT: FABRICATION AND/OR INSTALLATION OF THE SCHEDULED AIR CONDITIONING DISTRIBUTION AND DUCTWORK. B. C. SERVICE INTERNAL INSULATION: FIBROUS -GLASS DUCT LINING COMPLYING WITH ASTM C 1071, TYPE IL 5'-0" INTERVALS. CLEANING, TESTING AND ADJUSTING: THE MECHANICAL CONTRACTOR, AT HIS EXPENSE, SHALL CLEAN, REPAIR, ADJUST, CHECK, BALANCE, AND A. FABRICATE AND LABEL REFRIGERATION SYSTEM TO COMPLY WITH ASHRAE 15, "SAFETY CODE FOR 1. THICKNESS: 1 INCH (25 MM). 2. INSULATION ADHESIVE: COMPLY WITH ASTM C 916, TYPE I. PIPE SUPPORT: ATTACH LINES SECURELY ALONG PAD/FLOOR/EQUIPMENT/STRUCTURE TO PREVENT MOVEMENT. SUPPORT IN A MANNER THAT LINES DO NOT HANG FROM 3. STATIC PRESSURE THROUGH UNITS AND UNIT COMPONENTS. PLACE IN SERVICE THE VARIOUS SYSTEMS HEREIN SPECIFIED WITH THEIR RESPECTIVE EQUIPMENT, UNLESS NOTED OTHERWISE. AIR DISTRIBUTION SHALL NOT EXCEED NC -30 NOISE CRITERIA AS DEFINED IN THE LATEST ASHRAE GUIDE. 3. MECHANICAL FASTENERS: GALVANIZED STEEL, SUITABLE FOR ADHESIVE ATTACHMENT, MECHANICAL ATTACHMENT, OR WELDING ATTACHMENT TO CASING WITHOUT DAMAGING LINER AND WITHOUT CAUSING AIR EVAPORATOR CONNECTIONS OR BLOCK ACCESS TO FILTERS, CONTROLS, ETC. OVERCURRENT AND OVERTEMPERATURE PROTECTION, INTERNAL PRESSURE RELIEF, ACCESSORIES AND PIPING. HE SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS REQUIRED TO PERFORM TESTS REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING LEAKAGE WHEN APPLIED AS RECOMMENDED BY MANUFACTURER. SUPPORT AT MIN. 8'-0" INTERVALS FOR VERTICAL PIPES, 5'-0" FOR SUSPENDED HORIZONTAL PIPING. DUCTWORK: AUTHORITIES. D. CONDENSATE DRAIN PANS: FORMED SECTIONS OF STAINLESS-STEEL SHEET DESIGNED FOR SELF -DRAINAGE. SEAL D. REFRIGERANT: R -410A ON ALL NEW SYSTEMS. FABRICATE PANS WITH SLOPES TO PRECLUDE BUILDUP OF MICROBIAL SLIME. PROVIDE FLOAT SWITCH. EXHAUST FANS: ADDITIONALLY SYSTEMS DRAWING CLEARLY MARKED TO IDENTIFY LOCATION OF EQUIPMENT AND AIR. NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY INSPECTED AND TESTED. E. ROOF CURB: FULL -PERIMETER CURB OF SHEET METAL, MINIMUM 14 INCHES HIGH, WITH WOOD NAILER, DEVICES TESTED SHALL BE PROVIDED ALONG WITH THE WRITTEN TEST AND BALANCE REPORT. 3. ALL DUCTWORK SHOWN PER PLAN IS TO BE SHEET METAL. FIBERGLASS DUCT BOARD IS NOT TO Z BAR FLASHING FURNISH EXHAUST FANS WITH PERFORMANCE AND CAPACITIES AS LISTED ON THE DESIGN DRAWINGS. NOTE: ALL OF THE SPECIFICATIONS LISTED ON THIS SHEET MAY NOT BE USED FOR THIS PROJECT. DATES DA12011 CSC Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCENG.COM CA NO. 28730 \ 0� \\J �q'//// JLC 17.0258.00 IyV NEOPRENE SEALING STRIP, AND W - \VV^ %GENS�`. VF��� � w TESTING: ADJUST THE AIR CONDITIONING SYSTEMS, VENTILATING SYSTEMS, FANS, ETC., TO DELIVER NOT LESS 2.3 SUPPLY -AIR FAN SUSPENDED FANS SHALL BE SUPPORTED FROM A TRAPEZE TYPE HANGER WITH SPRING MOUNTED VIBRATION ISOLATORS. THAN THE REQUIRED AIR QUANTITY WITH QUANTITIES IN EXCESS TO BE SUBJECT TO THE APPROVAL OF THE ENGINEER IF FOUND TO NOT HAVE OBJECTIONABLE EFFECTS SUCH AS NOISE, DRAFTS, OR MOTOR A. FAN: FORWARD -CURVED CENTRIFUGAL; STATICALLY AND DYNAMICALLY BALANCED, GALVANIZED STEEL, ALL EXHAUST FANS SHALL COME WITH INTEGRAL BACKDRAFT DAMPER. /ONAi\ OVERLOAD. MOUNTED ON SOLID -STEEL SHAFT WITH SELF -ALIGNING, PERMANENTLY LUBRICATED BALL BEARINGS. `E TO THE OWNER B. MOTOR: TOTALLY ENCLOSED -SPEED MOTOR. C. DRIVE: V -BELT DRIVE. WITH MATCHING FAN PULLEY AND ADJUSTABLE MOTOR SHEAVES AND BELT ASSEMBLY COORDINATE WITH ARCHITECT TO LOCATE EXHAUST FANS, EXHAUST GRILLES, WALL OR ROOF CAPS A MINIMUM DISTANCE OF 10'-0" FROM ANY OPERABLE CONTRACTOR SHALL PROVIDE THREE 3 COPIES OF A TEST AND BALANCE REPORT THIS CONT O WITH MINIMUM 1.4 SERVICE FACTOR. WINDOW, DOOR OR FRESH AIR INTAKE. SPECIFICATIONS - MECHANICAL AT TIME OF SUBSTANTIAL COMPLETION INSPECTION. D. MOUNTING: .FAN WHEEL, MOTOR, AND DRIVES SHALL BE MOUNTED IN FAN CASING WITH SPRING ISOLATORS. SULLIVAN'S PUBLIC HOUSE AIR DISTRIBUTION EQUIPMENT: THE TEST AND BALANCE REPORT SHALL BE TYPEWRITTEN AND CONTAIN THE FOLLOWING DATA: 2.4 REFRIGERATION SYSTEM FURNISH SUPPLY AIR GRILLES AND RETURN AIR REGISTERS WITH OPPOSED BLADE BALANCING DAMPERS AS SCHEDULED ON THE DESIGN DRAWINGS. 1. DATE, TIME, WEATHER, WHEN TEST TAKEN. 2. AIR CAPACITIES AT EACH UNIT INCLUDING OUTSIDE AIR. (ENTERING AND LEAVING DB/WB) A. FABRICATE AND LABEL REFRIGERATION SYSTEM TO COMPLY WITH ASHRAE 15, "SAFETY CODE FOR GRILLES, REGISTERS, AND CEILING DIFFUSERS SHALL BE FURNISHED AS SCHEDULED ON THE DESIGN DRAWINGS AND SHALL BE ALL ALUMINUM CONSTRUCTION MILZARCH, LLC 01/31/18 3. STATIC PRESSURE THROUGH UNITS AND UNIT COMPONENTS. MECHANICAL REFRIGERATION." B. COMPRESSORS: RECIPROCATING OR SCROLL COMPRESSORS WITH INTEGRAL VIBRATION ISOLATORS, INTERNAL UNLESS NOTED OTHERWISE. AIR DISTRIBUTION SHALL NOT EXCEED NC -30 NOISE CRITERIA AS DEFINED IN THE LATEST ASHRAE GUIDE. 4. MOTOR OPERATING VOLTAGE AND AMPERAGE. OVERCURRENT AND OVERTEMPERATURE PROTECTION, INTERNAL PRESSURE RELIEF, 407.921.8795 MILZARCH@GAIL.COM SHEET M 5. DRIVE TYPES, SIZES AND SPEED RANGE. C. EER AND COP: 13 EER AND 11.8 COP VALUES AS DEFINED BY ASHRAE/IESNA 90.1, "ENERGY EFFICIENT DUCTWORK: 6. IDENTIFICATION OF ALL AIR TERMINAL DEVICES WITH DESIGN CFM AND ACTUAL CFM. DESIGN OF NEW BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS." SEAL D. REFRIGERANT: R -410A ON ALL NEW SYSTEMS. 1. ALL DUCTWORK DIMENSIONS ARE INSIDE NET FREE AREA. ADDITIONALLY SYSTEMS DRAWING CLEARLY MARKED TO IDENTIFY LOCATION OF EQUIPMENT AND AIR. E. REFRIGERATION SYSTEM SPECIALTIES: EXPANSION VALVE WITH REPLACEABLE THERMOSTATIC ELEMENT 2. SEAL ALL JOINTS WITH GLASS -FAB AND MASTIC. BE INSTALLED UNLESS SPECIFICALLY AUTHORIZED BY THE DEVICES TESTED SHALL BE PROVIDED ALONG WITH THE WRITTEN TEST AND BALANCE REPORT. 3. ALL DUCTWORK SHOWN PER PLAN IS TO BE SHEET METAL. FIBERGLASS DUCT BOARD IS NOT TO 1. REFRIGERANT DRYER. BUILDING LANDLORD, PROJECT OWNER/AGENT AND MECHANICAL ENGINEER OF RECORD. MAINTENANCE MANUALS 2. HIGH-PRESSURE SWITCH. 4. ALL EXHAUST AND OUTSIDE AIR DUCTWORK IS TO BE SHEET METAL - NO EXCEPTIONS. 3. LOW-PRESSURE SWITCH. 4. THERMOSTAT FOR COIL FREEZE-UP PROTECTION DURING LOW AMBIENT TEMPERATURE OPERATION OR ADJUSTABLE SPLITTERS AND DAMPERS SHALL BE SUPPLIED AND INSTALLED IN EVERY SPLIT AND BRANCH DUCT AND SHALL BE PROVIDED WITH LOCKING FOR EASE OF OPERATION. ACCESS PANELS OR YOUNG PROVIDE COMPLETE MAINTENANCE MANUALS (3 REQUIRED) ON ALL NEW EQUIPMENT. ORGANIZE QUADRANTS ON EXPOSED OR IN ACCESSIBLE AREAS OF THE DUCT OPERATING AND MAINTENANCE DATA INTO SUITABLE SETS OF MANAGEABLE SIZE. BIND PROPERLY WITH POCKET LOSS OF AIR. 5. BRASS SERVICE VALVES INSTALLED IN DISCHARGE AND LIQUID LINES. REGULATORS SHALL BE PROVIDED WHERE DAMPERS ARE INSTALLED ABOVE HARD CEILINGS OR IN SOFFITS EVEN IF NOT STATED ON PLANS.ELBOWS OR SHALL BE FITTED WITH AIR TURNS CONSISTING OF CURVED AIRFOIL BLADES OR VANES WHICH INDEXED .DATA INTO INDIVIDUAL, HEAVY-DUTY, DUTY, 2 -INCH, 3 -RING VINYL COVERED BINDERS 6. OPERATING CHARGE OF REFRIGERANT. CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES . FOLDERS FOR FOLDED SHEET INFORMATION. MARK APPROPRIATE IDENTIFICATION ON FRONT AND SPINE WILL PERMIT THE AIR TO MAKE ABRUPT TURNS WITHOUT APPRECIABLE TURBULENCE. OF EACH BINDER. INCLUDE THE FOLLOWING TYPES OF INFORMATION, THE INFORMATION WILL BE 2.5 CAPACITY CONTROL 5. ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES SHALL BE FITTED WITH AIR TURNS .CONSISTING OF CURVED AIRFOIL BLADES OR TURNED OVER TO THE OWNER AT TIME OF SUBSTANTIAL COMPLETION: VANES WHICH WILL PERMIT THE AIR TO MAKE ABRUPT TURNS WITHOUT APPRECIABLE TURBULENCE. LONG RADIUS TURNS ARE AN ACCEPTABLE SUBSTITUTE A. HOT -GAS BYPASS REFRIGERANT CONTROL FOR CAPACITY CONTROL WITH CONTINUOUS DEHUMIDIFICATION ON IF SPACE PERMITS. - OPERATING AND MAINTENANCE INSTRUCTIONS - SPARE PARTS LIST A SINGLE COMPRESSOR. - SHEET METAL DUCTWORK: SHALL BE CONSTRUCTED PER THE APPROPRIATE SMACNA DESIGN STANDARDS, MEETING THE MINIMUM GAUGE SHEET - COPIES OF WARRANTIES 2.6 REFRIGERANT COILS METAL THICKNESS SPECIFIED. INSULATE INTERNALLY OR EXTERNALLY WITH FIBERGLASS INSULATION TO ACHIEVE A MINIMUM R -VALUE OF 7.0 - WIRING DIAGRAMSUNLESS INSTALLED IN A MECHANICALLY COOLED SPACE OR BETWEEN COOLED FLOORS IN A CAVITY WHOSE EXTERIOR WALLS ARE INSULATED, IN WHICH CASE - INSPECTION REPORTS AND APPROVALS A. EVAPORATOR AND CONDENSER COILS SHALL BE DESIGNED, TESTED, FABRICATED, AND RATED ACCORDING TO THE R -VALUE MAY BE 4.2. - SHOP DRAWINGS AND PRODUCT DATA ARI 410 AND ASHRAE 33. COILS SHALL BE LEAK TESTED UNDER WATER WITH AIR AT 315 PSIG (2170 KPA). - FIBERGLASS DUCTWORK: SHALL BE CONSTRUCTED OF FIBERGLASS FIBERBOARD DUCTWORK TO BE A MINIMUM OF 1" THICK. FIBERGLASS DUCTWORK TRAINING SERVICES SHALL BE LINED WITH ANTI MICROBIAL INSULATION EQUAL TO JOHNS -MANVILLE SUPERDUCT. INSULATE FIBERGLASS SUPPLY AND RETURN 1. CAPACITY REDUCTION: CIRCUIT COILS FOR FACE CONTROL. DUCTS TO A MINIMUM R -VALUE OF 7.0 UNLESS INSTALLED IN A MECHANICALLY COOLED SPACE OR BETWEEN COOLED FLOORS IN A CAVITY WHOSE THOROUGHLY INSTRUCT THE OWNER'S REPRESENTATIVE IN THE OPERATION OF ALL EQUIPMENT 2. TUBES: COPPER. EXTERIOR WALLS ARE INSULATED, IN WHICH CASE THE R -VALUE MAY BE 4.2. FURNISHED AND LOCATION OF ALL VALVES AND CONTROL DEVICES. 3. FINS: ALUMINUM 4. FIN AND TUBE JOINT: MECHANICAL BOND. - FLEXIBLE DUCTWORK SHALL BE SPIRAL FORMED OUT OF 3003 BRIGHT REFLECTIVE FINISHED ALUMINUM ALLOY, MECHANICALLY LOCKED AND HAVE TRA AND SHUTDOWN IN BUILDING OWNER'S PERSONNEL DURING NORMAL WORKING HOURS ON STARTUP TUBE WITH BRAZED COPPER JOINTS. 5 5. COATING: PHENOLIC EPDXY . SUCTION AND DISTRIBUTOR: SEAMLESS CORROSION PROTECTION COATING BOTH COILS. A MINIMUM R -VALUE OF 6.0. IT SHALL BE UL LISTED UNDER CLASS 1 AIR DUCTS AND CLASS 1 CONNECTORS, MEET ALL REQUIREMENTS OF UL 181 PROCEDURES, TROUBLESHOOTING PROCEDURES, SERVICING AND PREVENTATIVE MAINTENANCE SCHEDULE 7• SOURCE QUALITY CONTROL: TEST TO 450 PSIG (3105 KPA), AND TO 300 PSIG (2070 KPA) AND COMPLY WITH NFPA 90A AND NFPA 90B. AND PROCEDURES. REVIEW WITH THE OWNER'S PERSONNEL, THE DATA CONTAINED IN THE OPERATING MANUALS. SCHEDULE TRAINING WITH OWNER, PROVIDE AT LEAST 7 -DAYS PRIOR UNDERWATER. - ROUND SPIRAL DUCTWORK: SHALL BE CONSTRUCTED PER THE APPROPRIATE SMACNA DESIGN STANDARDS, MEETING THE MINIMUM GAUGE SHEET AND MAINTENANCE NOTICE TO ARCHITECT/ENGINEER. B. CONDENSER FAN: PROPELLER TYPE, DIRECTLY DRIVEN BY MOTOR. METAL THICKNESS SPECIFIED AND SHALL BE A MINIMUM 1" DOUBLE WALL INTERNALLY INSULATED. NON INSULATED SPIRAL DUCTWORK WILL NOT BE C. SAFETY CONTROLS: ACCEPTED AS A SUBSTITUTION. HANGERS AND SUPPORTS 1. COMPRESSOR MOTOR AND OUTSIDE -COIL FAN MOTOR LOW AMBIENT LOCKOUT. VIBRATION ISOLATION: PROVIDE ALL NECESSARY HANGER RODS, CLAMPS AND ATTACHMENTS TO PROPERLY INSTALL AND 2. OVERCURRENT PROTECTION FOR COMPRESSOR MOTOR AND OUTSIDE -COIL FAN MOTORS. ALL BLOWER UNITS AND VIBRATING TYPE EQUIPMENT SHALL BE PROPERLY FITTED WITH MASON INDUSTRIES VIBRATION ISOLATION EQUIPMENT SIZED IN SUPPORT DUCTWORK, PIPING AND EQUIPMENT FROM THE BUILDING STRUCTURE. 2.7 FILTERS ACCORDANCE WITH EQUIPMENT WEIGHT AND DUTY. PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS REQUIRED TO INSTALL EQUIPMENT, A. COMPLY WITH NFPA 90A. PROVIDE FLEXIBLE CONNECTORS AT ALL SUPPLY AND RETURN CONNECTIONS TO AIR HANDLING EQUIPMENT CONSISTING OF HEAVY CANVAS OR NEOPRENE FABRIC PIPING AND DUCTWORK. B. DISPOSABLE PLEASTED FILTERS: 2 -INCH- (50 -MM-) THICK, FACTORY -FABRICATED, FLAT -PANEL -TYPE, WITH AIRTIGHT SEAMS AND CONNECTIONS TO THE EQUIPMENT. IR FILTERS WITH HOLDING FRAMES. DISPOSABLE A IR IL ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED, PRIMED AND PAINTED TO PREVENT C. FILTER MEDIA INTERLACED GLASS FIBERS SPRAYED WITH NONFLAMMABLE ADHESIVE. RUSTING. FINISH COLOR AS SELECTED BY OWNER. D. FILTER FRAMES TO BE GALVANIZED STEEL. AIR FILTERS: THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS NOT ACCEPTABLE FOR SUPPORTS. 2.8 CONTROLS FILTERS SHALL BE 1 FIBERGLASS MEDIA THROW AWAY TYPE IN A RIGID FRAME WITH A SUPPORTING MAZE ACROSS BOTH ENTERING AND LEAVING SURFACES. SUPPLY ONE COMPLETE SET OF FILTERS AFTER OWNER'S FINAL ACCEPTANCE. FARR 30/30 OR EQUAL. WARRANTY/GUARANTEE: A. FACTORY -WIRE CONNECTION FOR CONTROLS' POWER SUPPLY. B. CONTROL DEVICES, INCLUDING SENSORS, TRANSMITTERS, RELAYS, SWITCHES, THERMOSTATS, HUMIDISTATS, HEAT PUMP UNIT INSTALLATION: THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS DETECTORS, OPERATORS, ACTUATORS, AND VALVES, SHALL BE MANUFACTURER'S STANDARD ITEMS TO ACCOMPLISH INDICATED CONTROL FUNCTIONS. CONDENSING UNITS. PADS SHALL BE A MINIMUM OF 4" THICK, 3,000 PSI CONCRETE, AND SHALL BE 4" AND KEEP SAME IN PERFECT REPAIR AND CONDITION OF THE PERIOD OF ONE (1) YEAR. C. UNIT CONTROLS: SOLID-STATE CONTROL BOARD AND COMPONENTS WITH FIELD -ADJUSTABLE CONTROL PROVIDE CONCRETE PADS FOR GRADE MOUNTED LARGER ON EACH SIDE THAN THE FOOTPRINT OF THE CONDENSING UNIT. VERIFY UNIT DIMENSIONS WITH APPROVED SHOP DRAWINGS PRIOR TO FABRICATION DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PARAMETERS. D. SUPPLY -FAN CONTROL: UNITS SHALL BE ELECTRICALLY INTERLOCKED WITH CORRESPONDING EXHAUST OF PADS. PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE REPAIRS FANS, TO OPERATE CONTINUOUSLY WHEN EXHAUST FANS ARE RUNNING. TIME CLOCK SHALL SWITCH SUSPENDED UNITS SHALL BE SUPPORTED IN APPROVED MANNER AND IN ACCORDANCE WITH AIR HANDLING UNIT SUPPORT DETAIL. PROVIDE AUXILIARY. OVERFLOW RECONSTRUCTION AND SATISFACTION OF THE OWNER AND ARCHITECT AND ENGINEER. SUCH RECO OPERATION FROM OCCUPIED TO UNOCCUPIED. NIGHT SETBACK THERMOSTAT SHALL CYCLE FAN DURING PAN WITH FLOAT SWITCH WHERE REQUIRED. SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE UNOCCUPIED PERIODS TO MAINTAIN SPACE TEMPERATURE. DRAIN ORIGINAL DEFECT OR REPAIRS THERETO. 1. TIMER: SEVEN-DAY ELECTRONIC CLOCK. ALL AIR HANDLING UNITS AND CONDENSING UNITS SHALL BE INSTALLED WITH MANUFACTURER REQUIRED MINIMUM MAINTENANCE CLEARANCES. PROVIDE MAN EQUIPMENT: SIZED ACCESS PANEL WHERE REQUIRED. E. ELECTRICALLY INTERLOCK KITCHEN HOOD FIRE -EXTINGUISHING SYSTEM TO DE -ENERGIZE REPLACEMENT -AIR 1.1 QUALITY ASSURANCE UNIT WHEN FIRE -EXTINGUISHING SYSTEM DISCHARGES. F. MINIMUM REFRIGERATION SYSTEM CONTROLS SHALL CONSIST OF A WALL -MOUNTING, RELATIVE -HUMIDITY AND FIRE DAMPERS: A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, TEMPURATURE SENSOR THAT ENERGIZES DEHUMIDIFIER OPERATION WHEN RELATIVE HUMIDITY IS MORE THAN FIRE DAMPERS SHALL BE TYPE "B" CURTAIN TYPE, SUITABLE FOR EITHER VERTICAL OR HORIZONTAL INSTALLATION WITH 20 GAUGE STEEL CHANNEL FRAMES, 24 ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR 60 PERCENT. GAUGE STEEL BLADES, AND 18 GAUGE STEEL ENCLOSURE WITH DUCT COLLARS. ALL PARTS GALVANIZED MILL FINISH. INTENDED USE. B. UNITS SHALL BE DESIGNED TO OPERATE WITH HCFC -FREE REFRIGERANTS. PIN FIRE DAMPERS SHALL BE EQUAL TO RUSKIN TYPE 1 BD2 FOR WALLS UP TO 2 HOUR. 1.2 WARRANTY CONDENSATE DRAINS: INSTALL IN ACCORDANCE WITH NEPA-90A, TESTED IN ACCORDANCE WITH UL SAFETY STANDARD 555, 1-1/2 HOUR AND 4 HOUR PROTECTION, AND 165'F A. SPECIAL WARRANTY: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO REPLACE CONDENSATE PIPE TO BE TYPE L OR PVC. ROUTE TO DRYWELL OR AS INDICATED ON PLANS. FUSIBLE LINK. COMPONENTS LISTED BELOW THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED WARRANTY COORDINATE WITH PLUMBER TO PROVIDE HUB DRAIN(S) IN MECHANICAL ROOM AND DRYWELL(S). HVAC PERIOD. CONTRACTOR TO PROVIDE P -TRAP AT UNIT SIZED FOR 2" GREATER THAN UNIT STATIC PRESSURE. 1. WARRANTY PERIOD FOR COMPRESSORS: MANUFACTURER'S STANDARD, BUT NOT LESS THAN FIVE (5) PROVIDE CLEANOUT AT UNIT FOR SUSPENDED HORIZONTAL AIR HANDLERS. INSULATE CONDENSATE PIPE WITH 1/2" ARMAFLEX (OR EQUAL) INSULATION RATED FOR PLENUM APPLICATION. CONDENSATE DRAIN YEARS FROM DATE OF SUBSTANTIAL COMPLETION. 2. WARRANTY PERIOD FOR HEAT EXCHANGERS: MANUFACTURER'S STANDARD, BUT NOT LESS THAN FIVE LINE SHALL BE NOT LESS THAN THE EQUIPMENT DRAIN LINE SIZE AND IN NO CASE LESS THAN 3/4" (5) YEARS FROM DATE OF SUBSTANTIAL COMPLETION. PIPE SIZE. 1.3 MANUFACTURERS REFRIGERANT PIPING: A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE COVER ALL EXPOSED LIQUID LINES AND ALL SUCTION PIPING (INDOORS AND OUTDOORS), FITTINGS, FOLLOWING: VALVES, ETC., CONTINUOUS THROUGH SLEEVES, HANGERS, ETC., WITH 1/2" FR/ARMAFLEX. INSTALLATION 1. MON SHALL BE CONDENSATION FREE AND INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 2. TRANE 3. CARRIER REFRIGERANT PIPING BELOW GRADE SHALL BE ROUTED THROUGH MINIMUM 4" DIAMETER PVC PIPE 4. YORK 5. COMFORT MAKER SLEEVES TO EACH CONDENSING UNIT. ALL UNDERGROUND REFRIGERANT PIPING SHALL BE CONTINUOUS 6. LENNOX WITH NO UNDERGROUND JOINTS ALLOWED. REFRIGERANT PIPE SIZES SHALL BE SIZED PER A/C EQUIPMENT MANUFACTURER'S RECOMMENDATION BASED ON LENGTH OF RUN BETWEEN CONDENSING UNITS AND AHU UNITS. NOTE: ALL OF THE SPECIFICATIONS LISTED ON THIS SHEET MAY NOT BE USED FOR THIS PROJECT. DATES DA12011 CSC Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCENG.COM CA NO. 28730 \ 0� \\J �q'//// JLC 17.0258.00 IyV \VV^ %GENS�`. VF��� � w No. 69124 -p ir` Adam J Barney Q ' , STATE OF �(/' 2018.01.31 15:16:01-05'00' /ONAi\ `E This itom hes been electron'celiy signed and saalad by Adam Joseph Barney Adam J, Berney, PE on the Date andlor Time 81emp shown P.E. #: 69124 using a digital eignzture. Printed copies of this document are net o-ldered signed and sealed and the signature must be verified on any electronic capias SPECIFICATIONS - MECHANICAL SULLIVAN'S PUBLIC HOUSE 116 E FIRST STREET SANFORD, FL 32771 100% CDs MILZARCH, LLC 01/31/18 JERRY WALKER MILLS, SR. 407.921.8795 MILZARCH@GAIL.COM SHEET M AR0008314 M6.1 701 WEST Third Street, Sanford, Fl. 32771 SEAL 111 I RI N G WIRING /� AND ELECTRICAL [� E POWER O LEGEND ©�` h- AN E Lv J - JUNCTION ABBREVIATIONS GENERAL NOTES Pp 1) ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL THE BUILDING CODE. V V (- V V I ` OPERATIONAL, WITH THE SAME CAPACITY AS BEFORE. ALL BUILDING SURFACES DAMAGED, AND OPENINGS A — AMPERES ELECTRICAL CODE (NFPA 70), AND THE LATEST ADOPTED EDITION OF FLORIDA LC LIGHTING CONTACTOR KAIC — (THOUSAND) AMPERE INTERRUPTING CAPACITY LEFT BY REMOVAL OF BOXES, PIPING OR OTHER EQUIPMENT SHALL BE REPAIRED BY THE CONTRACTOR. A/C — AIR CONDITIONING ® RECESSED FLOOR MOUNTED DUPLEX RECEPTACLE S* SWITCH NEW ELECTRICAL PANEL 2) CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND COORDINATE WITH EXISTING EQUIPMENT PRIOR TO PC PHOTOCELL KVA — XXX AC — ALTERNATING CURRENT BIDDING. Q SURFACE -MOUNTED FLOOR DUPLEX RECEPTACLE NONE SINGLE POLE TOGGLE SWITCH KILOWATT MDP MAIN DISTRIBUTION PANEL (SEE PANEL SCHEDULE) AFF - ABOVE FINISHED FLOOR S 2 TWO POLE TOGGLE SWITCH TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION AFG — ABOVE FINISHED GRADE 3) ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABEL LISTED BY AN ® O CEILING—MOUNTED DUPLEX RECEPTACLE * 3 THREE WAY TOGGLE SWITCH LIGHTING APPROVED THIRD—PARTY TESTING AGENCY. WP SINGLE POLE WEATHERPROOF SWITCH ATS AUTOMATIC TRANSFER SWITCH AHU — AIR HANDLING UNIT cry?. PLUG MOLD K OS SINGLE POLE KEYED SWITCH OCCUPANCY SENSOR SWITCH ® SYSTEMS PANEL ELECTRICAL Y AWG _ AMERICAN,. WIRE GAUGE BUILDING; M MANUAL MOTOR CONTROLLER W/0 OVERLOADS XXX C - CONDUIT 4) INSTALLATION HEIGHT OF EQUIPMENT (TO CENTERLINE) ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE C COUNTER HEIGHT MCP — MOTOR CIRCUIT PROTECTION SACP SECURITY ALARM CONTROL PANEL CFL - COMPACT FLUORESCENT LAMP SHALL BE: MH — METAL HALIDE FACP FIRE ALARM CONTROL PANEL = 0 JUNCTION BOX S LOWER CASE LETTERS INDICATES SWITCHING DESIGNATIONS, MC MASTER CLOCK CONTROL PANEL CH - COUNTER HEIGHT RECEPTACLE 18" abc Q UANTITY OF LETTERS EQUAL QUANTITY OF GANGED SWITCHES N — PA PUBLIC ADDRESS. CONTROL PANELCLOCK CONIC — CONCRETE 7'-6° SWITCH 44" DISCONNECT SWITCH NA — IMP FIRE ALARM ANNUNCIATOR PANEL COND - CONDUIT MODULAR JACK FOR WALL MOUNTED TELEPHONE = 52" DW13 DISCONNECT SWITCH — WEATHERPROOF (NEMA 3R) NF — NON—FUSED WIRING: MODULAR TELEPHONE JACK = 18" m SINGLE RECEPTACLE CU — COPPER TELEVISION OUTLET = 84" F FUSED DISCONNECT SWITCH 'j'' C `/� 1 n' I C '�' I N I I O N TELECOMMUNICATIONS E L E O I NL - LIGHTING CIRCUIT HOME RUN SHALL BE THREE (3) #12 AWG THHN/THWN (1 HOT, 1 NEUTRAL & 1 EQUIPMENT COMPUTER OUTLET = 18"CLL GFI GROUND FAULT CIRCUIT INTERRUPTER DISC — DISCONNECT SWITCH = 44" WP WEATHERPROOF NEMA — NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION DEVICE UNLESS NOTED OTHERWISE. COMBINED NEUTRALS ARE NOT PERMITTED. — ENCLOSED CIRCUIT BREAKER REMOTE TEST STATION FOR DUCT DETECTOR = 52" © MAGNETIC MOTOR STARTER IG ISOLATED GROUND .ECB C = ABOVE COUNTER BACKSPLASH, COORDINATE WITH ARCHITECTURAL ELEVATIONS AND MILLWORK. C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) XX LIGHTING FIXTURE ELEC - ELECTRICAL COMBINATION FUSED DISCONNECT/ Q TELEVISION OUTLET Q (SEE LIGHTING FIXTURE SCHEDULE FOR LETTER EM - EMERGENCY 5) ALL CONDUIT AND WIRING SHALL BE CONCEALED IN WALLS OR ABOVE CEILINGS UNLESS NOTED * MAGNETIC STARTER SWITCH ® DESIGNATION AND DESCRIPTION OF FIXTURES) EMS — ENERGY MANAGEMENT SYSTEM OTHERWISE OR .APPROVED BY THE ARCHITECT/ENGINEER. .ALL DEVICE OUTLET BOXES SHALL BE 9* DUPLEX RECEPTACLE F---1 O.C. — ON CENTER a. ON DEMOLITION AND NEW WORK PLANS - DEVICES AND EQUIPMENT SHOWN IN LIGHT LINETYPE ARE RECESSED UNLESS NOTED OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. WHERE APPROVED tl HOA HAND/OFF/AUTOEXISTING O.F.C.I. — EF - EXHAUST FAN OR NOTED SURFACE METAL RACEWAY AND DEVICE BOXES SHALL BE USED IN LIEU OF CONDUIT AND GFI GROUND FAULT CIRCUIT INTERRUPTEREMERGENCY/NIGHT EMT _ ELECTRICAL METALLIC TUBING CONCEALED BOXES AT NO EXTRA COST TO THE OWNER: WP WEATHERPROOF ® LIGHT LIGHTING FIXTURE POLE REMOVED IG ISOLATED GROUND EWC - ELECTRIC WATER COOLER 6) ALL CONDUIT ROUTES SHOWN ARE APPROXIMATE ONLY. CONTRACTOR SHALL FIELD VERIFY FINAL ROUTE. ® M C COUNTER HEIGHT ABOVE COUNTER OR 42" AFF) ( ® EXIT LIGHTING FIXTURE UNIVERSAL MOUNT, SINGLE/DOUBLE FACE ETR - EXISTING TO REMAIN QQ CSC VSD EWC ELECTRIC WATER COOLER, COORDINATE LOCATION ( WHERE USED, ARROW INDICATES CHEVRON DIRECTION) EX — EXISTING 7) .CONDUIT RUNS SHOWN ARE SCHEMATIC. AND DO NOT INDICATE THE NECESSARY FITTINGS .AND JUNCTION WITH PLUMBING CONTRACTOR RGS — RIGID GALVANIZED STEEL BOXES THAT ARE INCLUDED IN THE SCOPE OF THE WORK. Joseph. Lawnence o VSD VARIABLE SPEED DRIVE BATTERY POWERED EMERGENCY LIGHT FA - FIRE ALARM Consulting Engineeips 8) CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL WIRING WITH THE SOURCE AND CIRCUIT AT ALL , �("`�� /(D/EF-1 EF -1 QUADRAPLEX RECEPTACLE —4 EMERGENCY LIGHT REMOTE HEAD FAAP — FIRE ALARM ANNUNCIATOR PANEL ELECTRICAL EQUIPMENT, PULL AND JUNCTION BOXES AND ELECTRICAL TERMINATIONS PROVIDED OR 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 FACP — FIRE ALARM CONTROL PANEL ASSOCIATED WITH THIS CONSTRUCTION. TEL: 321.972.4466 w M TC GROUND FAULT CIRCUIT INTERRUPTER F- TK —i TRACK LIGHTING CA NO. 29730 CA NO, 28730 ,GFI WP WEATHERPROOF G — GROUND 9) CONTRACTOR SHALL PATCH AND REPAIR ALL DAMAGED SURFACES AND AREAS WHERE EQUIPMENT WAS \�Ilillllll///� ` �TYP IG ISOLATED GROUND TRACK LIGHTING HEAD GFI - GROUND FAULT INTERRUPTER REMOVED OR MODIFIED, TO MATCH EXISTING CONDITIONS. cSSp--""x/�� P' cru JLC 17.0258.00 C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) WG WIRE CAGE LIGHT GUARD GND — GROUND 10) ALL ABANDONED AUDIO OR CONTROL CABLES SHALL BE REMOVED. ALL BOX OR EQUIPMENT OPENINGS m�' ti GRC — GALVANIZED RIGID CONDUIT SHALL BE CLOSED WITH LISTED CLOSURE DEVICE AS APPROVED BY THE EQUIPMENT MANUFACTURER. No. sso6o O* SPECIAL RECEPTACLE OS OCCUPANCY SENSOR — CEILING MOUNTED H.I.D. — HIGH INTENSITY DISCHARGE 1 1) WHERE EXISTING EQUIPMENT OR MATERIALS ARE REMOVED OR CHANGED, ALL BRANCH CONDUITS. WHICH -1 •' * it X TYPE X (SEE RECEPTACLE SCHEDULE) OSC OCCUPANCY SENSOR — CEILING MOUNTED - CORRIDOR HVAC — HEATING, VENTILATING, AND AIR CONDITIONING NO LONGER ARE IN SERVICE, SHALL BE REMOVED AS DIRECTED BY THE ENGINEER. IF, IN THE COURSE THIS WORK, OUTLETS ARE COVERED UP OR OTHERWISE RENDERED INACCESSIBLE, ALL WIRING TO � -•p , Blake L Suddeth ,� C COUNTER HEIGHTOF I.G. — ISOLATED GROUND SAME SHALL BE REMOVED TO THE SOURCE. IF A CIRCUIT THAT MUST REMAIN IN SERVICE IS INTERRUPTED �0� STATE o� ' �w� 2018.01.31 15:06:46-05'00' BRANCH CIRCUIT WIRING, PROVIDE QUANTITIES OF CONDUCTORS oSW OCCUPANCY SENSOR - WALL MOUNTED _ WP WEATHERPROOF , J - JUNCTION THEREBY, IT SHALL BE RECONNECTED BY THE MOST INCONSPICUOUS MEANS SO AS TO REMAIN Pp POWER POLE OPERATIONAL, WITH THE SAME CAPACITY AS BEFORE. ALL BUILDING SURFACES DAMAGED, AND OPENINGS LC LIGHTING CONTACTOR KAIC — (THOUSAND) AMPERE INTERRUPTING CAPACITY LEFT BY REMOVAL OF BOXES, PIPING OR OTHER EQUIPMENT SHALL BE REPAIRED BY THE CONTRACTOR. ® RECESSED FLOOR MOUNTED DUPLEX RECEPTACLE ALL HOLES LEFT IN JUNCTION BOXES, SWITCHES, PANELS, ETC. SHALL BE CLOSED. PC PHOTOCELL KVA — KILOVOLT—AMPERES Q SURFACE -MOUNTED FLOOR DUPLEX RECEPTACLE KW — KILOWATT 12) ALL REUSABLE DEVICES, FIXTURES AND EQUIPMENT SHALL BECOME THE PROPERTY OF THE OWNER. ALL S SWITCH OTHER SALVAGE AND DEBRIS SHALL BE REMOVED FROM THE PREMISES DAILY. ® O CEILING—MOUNTED DUPLEX RECEPTACLE * LTG — LIGHTING OS OCCUPANCY SENSOR SWITCH MCM — THOUSANDS OF CIRCULAR MILS 13) THIS CONTRACTOR SHALL FURNISH AND PROVIDE ALL DEMOLITION REQUIRED TO ACCOMMODATE THIS cry?. PLUG MOLD D DIMMERPROJECT WHETHER INDICATED ON DRAWINGS, OR DIRECTED IN THE FIELD. D3 THREE WAY DIMMER (INCANDESCENT) MCU — MASTER CONTROL UNIT C COUNTER HEIGHT MCP — MOTOR CIRCUIT PROTECTION GROUNDING: MH — METAL HALIDE 14) ALL METAL RACEWAYS, INCLUDING CONDUIT, WIRE TROUGHS, WIREMOLD, ETC., SHALL BE GROUNDED. ALL 0 JUNCTION BOX CONNECTIONS IN METAL RACEWAYS SHALL BE COMPLETED IN SUCH A MANNER AS TO MAINTAIN A N — NEUTRAL CONTINUOUS PATH TO GROUND THROUGHOUT THE ENTIRE LENGTH OF THE RACEWAY. DISCONNECT SWITCH NA — NOT APPLICABLE DW13 DISCONNECT SWITCH — WEATHERPROOF (NEMA 3R) NF — NON—FUSED WIRING: 15) UNLESS NOTED OTHERWISE ON THE DRAWINGS OR ON THE EQUIPMENT WIRING SCHEDULE, EACH BRANCH F FUSED DISCONNECT SWITCH 'j'' C `/� 1 n' I C '�' I N I I O N TELECOMMUNICATIONS E L E O I NL - NIGHT LIGHT CIRCUIT HOME RUN SHALL BE THREE (3) #12 AWG THHN/THWN (1 HOT, 1 NEUTRAL & 1 EQUIPMENT V V 1 V I V VA I NEC - NATIONAL ELECTRICAL CODE GROUND) IN 3/4" EMT CONDUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1—POLE OVERCURRENT NEMA — NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION DEVICE UNLESS NOTED OTHERWISE. COMBINED NEUTRALS ARE NOT PERMITTED. © MAGNETIC MOTOR STARTER v DATA/COMM OUTLET NFPA — NATIONAL FIRE PROTECTION ASSOCIATION EXISTING DEVICES TO REMAIN: COMBINATION FUSED DISCONNECT/ Q TELEVISION OUTLET NIC — NOT IN CONTRACT * MAGNETIC STARTER SWITCH 16) UNLESS OTHERWISE NOTED: SP SPEAKER O.C. — ON CENTER a. ON DEMOLITION AND NEW WORK PLANS - DEVICES AND EQUIPMENT SHOWN IN LIGHT LINETYPE ARE HOA HAND/OFF/AUTOEXISTING O.F.C.I. — OWNER FURNISHED CONTRACTOR INSTALLED TO REMAIN. b. ON DEMOLITION PLANS — DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE EXISTING TO BE SS START/STOP P - POLE REMOVED c. ON NEW WORK PLANS — DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE NEW. ® M MANUAL STARTER PNL — PANELBOARD QQ CSC VSD COMBINATION VARIABLE SPEED DRIVE AND DISCONNECT PVC — POLYVINYL CHLORIDE RGS — RIGID GALVANIZED STEEL Joseph. Lawnence o VSD VARIABLE SPEED DRIVE RM — ROOM Consulting Engineeips �("`�� /(D/EF-1 EF -1 MOTOR WITH DESIGNATOR SPEC — SPECIFICATION 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 SS - STAINLESS STEEL TEL: 321.972.4466 w M TC TIME CLOCK CA NO. 29730 CA NO, 28730 TVSS — TRANSIENT VOLTAGE SURGE SUPPRESSION \�Ilillllll///� ` �TYP S WATER HEATER — TYPICAL cSSp--""x/�� P' cru JLC 17.0258.00 m�' ti LION , — UNLESS OTHERWISE NOTED No. sso6o HVP1-6 BRANCH CIRCUIT HOME RUN WITH PANEL NAME AND CIRCUIT NUMBER, V — VOLTS -1 •' * it QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS � -•p , Blake L Suddeth ,� W — WIRE �0� STATE o� ' �w� 2018.01.31 15:06:46-05'00' BRANCH CIRCUIT WIRING, PROVIDE QUANTITIES OF CONDUCTORS _ WP WEATHERPROOF , REQUIRED FOR CIRCUITING AND SWITCHING INDICATED /0NAL �1 ?: POWER LEG ONLY (NO SWITCH LEG BETWEEN ROOMS) This Item has been electronically signed and sealed by Blake Lawrance Suddeth Blake L. Suddoih, PE on the Date and/or Tbno Stamp shown using a digital algnature, Printed copies o(this document are. P.E. #: 6906`0 MUSHROOM HEAD PUSH BUTTON not conaldered signed and sealed and the signature muel be verified onany electronic copies _ ..._._.._.__... _._.__....... (EMERGENCY STOP) 0 RELAY LEGEND & NOTES - ELECTRICAL GROUND ROD TT TRANSFORMER T TYPE "K" TRANSFORMER SULLIVAN'S PUBLIC HOUSE ❑K 116 E FIRST STREET UH ELECTRIC UNIT HEATER FURNISHED UNDER DIV 15 UNLESS NOTED OTHERWISE) SANFORD, FL 32771 ( 100% CDs MILZARCH, LLC 01/31/18 JERRY. WALKER MILLS, SR. 407.921.8795 MILZARCH@GMAIL.COM SHEET NOTE: SYMBOLS SHOWN ON THIS ELECTRICAL LEGEND ARE FOR AROOO8314 EO.1 REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLS MAY NOT BE USED FOR THIS PROJECT. 701 WEST Third Street, Sanford, F1. 32771 DATE, OA12011 SEAL TYP. EF 1 WP WP GFI 1GO 8O 3WIT PK1-2 PK1-38:40:42 M 10-1) WP c 0 WP PK1-34 PK1-31:33 f 2 NEW COOLER) CONDENSER C� WP PK1-43 ICE MACHINE CONDENSER PARTIAL ROOF PLAN - POWER & SYSTEMS Scale: 1/4 = 1'-0" REFERENCE NOTES: 0 ELECTRICAL CONTRACTOR SHALL COORDINATE DISCONNECT AND FUSE REQUIREMENTS FOR MECHANICAL UNIT WITH MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER PRIOR TO ROUGH—IN AND PROVIDE AS REQUIRED. ELECTRICAL CONTRACTOR SHALL COORDINATE DISCONNECT AND FUSE REQUIREMENTS FOR FOOD SERVICE COOLER/FREEZER UNIT WITH FOOD SERVICE EQUIPMENT SUPPLIER PRIOR TO ROUGH -IN AND PROVIDE AS REQUIRED. 0 LIGHTING FIXTURES FURNISHED WITH COOLER/FREEZER EQUIPMENT. O WEATHERPROOF JUNCTION BOX FOR CONNECTION OF COOLER/FREEZER DOOR/LIGHTS/ETC. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH -IN. O CONNECT FRACTIONAL HORSEPOWER EXHAUST FAN TO OPERATE WITH OCCUPANCY CONTROLLED LIGHTING THIS ROOM. `��11111111/�7� No.69060 -t7 Blake L Suddeth �3(� STATE OF (� 2018.01.31.15:07:24-05'00' E This Item has been electronicallysigned and sealed by Blake L. Suddoth. PE on the Date endlor Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be veriped on any electronic copies CX Joseph, Lowpence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCENG.COM CA NO. 28730 JLC 17.0258.00 Blake Lawrence Suddeth P.E. #: 69060 LIGHTING FIXTURE SCHEDULE MARK DESCRIPTION MANUFACTURER MODEL VOLTS LAMP FIXTURE WATTS QTY WATTS MODEL A LED TRACK HEAD/LUMINIARE, DIE-CAST ALUMINUM & WAC LIGHTING J -1023F -380 -BK 120 LED 22 CHANGEABLE LENS. BLACK FINISH. B 4" APERTURE LED ARCHITECTURAL RECESSED DOWN LIGHT, CREE LIGHTING KR4-13L-30K-120V 120 - - LED 18 MINIMUM 90 CRI C 6" APERTURE LED ARCHITECTURAL RECESSED DOWN LIGHT, CREE LIGHTING KR6-13L-30K-120V 120 - - LED 18 MINIMUM 90 CRI CF MILK GLASS GLOBE/52" CEILING FAN AS SELECTED BY OWNER BY OWNER AS SELECTED BY OWNER 120 - - INC 300 MAX F 4" SQUARE LED ARCHITECTURAL RECESSED DOWN LIGHT, WAC LIGHTING R3BRD-F-930-BN/RSBNICA-10 120 - - LED 11 MINIMUM 90 CRI P1 DECORATIVE PENDANT CHANDELIER BY OWNER AS SELECTED BY OWNER 120 - - INC MAX 50OW P2 DECORATIVE PENDANT BY OWNER AS SELECTED BY OWNER 120 - INC MAX 150W 4'-0" LENGTH, 120 VOLT SINGLE CIRCUIT TRACK - PROVIDE T4 WITH END FEEDS, CONNECTORS, END CAPS, AND REQUIRED WAC LIGHTING (1) HT4-BK 120 - - - 30OW MAX ACCESSORIES. BLACK FINISH 6'-0" LENGTH, 120 VOLT SINGLE CIRCUIT TRACK - PROVIDE T6 WITH END FEEDS, CONNECTORS, END CAPS, AND REQUIRED WAC LIGHTING (1) HT6-BK 120 - - - 450W MAX ACCESSORIES, BLACK FINISH. W1 WALL MOUNTED EXTERIOR LED LUMINAURE - TYPE 3 CREE LIGHTING XSPW-A-0-3-F-C-1-Z 120 - - LED 42 DISTRIBUTION EM WALL MOUNTED EMERGENCY LIGHT WITH THERMOPLASTIC LIGHTALARMS LCA-2MRS 120 - - LED 7.5 HOUSING, TWIN HEADS AND BATTERY BACKUP EM2 CEILING/PENDANT MOUNTED EMERGENCY LIGHT WITH LIGHTALARMS LCA-2MRS 120 - - LED 7.5 THERMOPLASTIC HOUSING, TWIN HEADS AND BATTERY BACKUP X1 UNIVERSAL EXIT SIGN WITH THERMOPLASTIC HOUSING, RED LIGHTALARMS QLXN500-EN 120 - - LED - LETTERS. & BATTERY BACKUP XE COMBINATION EXIT SIGN & EMERGENCY LIGHT W/ LIGHTALARMS UQLXN500-R-2LD1 N 120 - - LED 7.5 THERMOPLASTIC HOUSING, & BATTERY BACKUP NOTES: 1. ALL FIXTURES AND FINISHES SHALL BE APPROVED BY ARCHITECT/OWNER PRIOR TO ORDERING. 2. ALL FIXTURES SHALL INCLUDE LAMPS. 3. TYPE 'DS' - COORDINATE EXACT SLOPED CEILING ADAPTER REQUIRED FOR CEILING AS REQUIRED. GENERAL NOTES: A. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS AND ORIENTATIONS. B. REFER TO ARCHITECTURAL ELEVATIONS AND SECTIONS FOR ADDITIONAL LIGHTING FIXTURE MOUNTING DETAILS AND INFORMATION. C. ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE CONNECTED "HOT" TO THE INDICATED LOCAL LIGHTING CIRCUIT. D. VERIFY ALL MOUNTING HEIGHTS AND PENDANT LENGTHS WITH ARCHITECT AND ENGINEER PRIOR TO ORDERING FIXTURES. E. EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A PERIOD OF 90 MINUTES IN THE EVENT OF FAILURE OF NORMAL LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOTCANDLE (10 LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOTCANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOTCANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOTCANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40:1 SHALL NOT BE EXCEEDED. REFERENCE NOTES: O ( CONNECT VIA LIGHTING CONTACTOR 'LC1' FOR TIME OF DAY LIGHTING CONTROL. 0 'NL' INDICATES 'NIGHT LIGHT'. WIRE FIXTURE FOR CONTINUOUS (NON -SWITCHED) OPERATION 0 LOWER CASE LETTER ('a', 'b', ETC.) INDICATES SWITCH/DIMMER CONTROL. CONNECT VIA SWITCH/DIMMER AS INDICATED ON PLAN(S) ® CONNECT TO LIGHTING ASSOCIATED WITH LOWER CASE LETTER INDICATED. ® 1 Joseph, Lowipence & Co Consulting Engineeps 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCENG.COM CA NO. 28730 ��Il�illll�ri�� L SU '% JLC 17.0258.00 'LICENsi •�j�' No. 69060 ip Blake L Suddeth (p STATE OF 2018.01.31 15:07:53-05'00' Alt IDP,•.•��_ cc S�QNA40\? This Item has been electronicallysigned and sealed by /. ,1,J SlakaL Suddath PE on the Data and/., Time Stamp a h.- Blake Lawrence SUddeth using digital algnature Printed mpies of this document are net edneldamd signed and sealed and the signature muA be P.E. .�µ{ m: 69060 verlflad an any electronic poples \ #6 CU. GND BUILDING #2 CU STEEL #2 CU (2) 2" EMPTY CONDUIT FOR TELEPHONE/CABLE _ TV SERVICE. COORDINATE ROUTING AND EXACT TELECOM CONNECTION POINTS WITH LOCAL METALLIC WATER PIPE TELEPHONE/CABLE COMPANY CONCRETE ENCASED TELECOMMUNICATIONS RISER DIAGRAM POWER RISER DIAGRAM No Scale No Scale PANEL'PK1' LOCATION: TENANT SPACE VOLTAGE: 208Y/120V 30 4W MIN. AIC RATING: 22K AIC NOTES: PROVIDE TYPED WRITTEN DIRECTORY PROVIDE GROUND &NEUTRAL BUS 1 2f �'�0/208� V MAINS: 300A ® MLO ❑ MCB MOUNTING: SURFACE FED FROM: SERVICE DISC. SW. "LK1" ❑ FEED-THRU ENCLOSURE: NEMA 1 ~ CIRCUIT DESCRIPTION N o z 4 METER 30, 4W LOAD KVA LOAD KVA 300A MLO120/208V BRANCH CIRCUIT rn o z CIRCUIT DESCRIPTION r - � 0 NEUT GND COND qJ NEUT GND 30, 4W 3/4"C (MIN) W/PULL STRING 11"C: W/PULL STRING c N SPD LIGHTS - DINNING TRACK 12 12 12 1/2" 20/1 © R E F E R E N C E N O I'j' REFERENCE E S A 0.36 3 12 12 12 2 IRECEPTACLE - ROOF 2 3 LIGHTS - DINNING TRACK 12 12 12 1/2" 20/1 1.20 B 0.36 20/1 12 12 12 1/2" RECEPTACLE - BAR AREA 4 5 LIGHTS - DINNING TRACK 0 1 NEW 120/208V, 30, 4W OVERHEAD SERVICE WEATHER HEAD. COORDINATE ALL 12 1/2" 20/1 1.35 1 C 0.54 20/1 12 12 12 1/2" RECEPTACLE - DINNING s 7 LIGHTS - DINNING TRACK CONNECTION REQUIREMENTS OF NEW SERVICE WITH LOCAL UTILITY COMPANY PRIOR TO 12 12 1/2" 20/1 1,35 1 A 0.54 20/1 12 12 12 1/2" FIRST FLOOR 8 ROUGH -IN AND PROVIDE AS REQUIRED. LIGHTS - DINNING TRACK NEW 12 12 12 1/2" 20/1 1.20 B 0.74 20/1 12 12 12 2 O PROVIDE HARD WIRED SURGE PROTECTIVE DEVICE OF SAME MANUFACTURER AS RECEPTACLE - BEER FRIDGE 10 11 NEMA 3R 12 12 12 1/2" 20/1 1.20 C 1 0.74 20/1 12 DISCONNECT SWITCH. 12 ENCLOSED MAIN TELEPHONE IRECEPTACLE TYP. TELECOM OUTLET TYP. DATA OUTLET - NDING JUMPER\ PROVIDE INTER SYSTEM BOO 13 LIGHTS - BAR TRACK -4#500 kcmil AL., 1#2 AWG: AL. GND., 4"C. 12 3 PROVIDE HEAVY DUTY 400A, 250V, 30, 4W, NEMA 3R, SERVICE ENTRANCE RATED 20/1 TERMINATION A 1.20 20/1 12 12 12 1/2" RECEPTACLE - ICE MACHINE DISCONNECT SWITCH FUSED AT 30OAMPS. PROVIDE PHENOLIC LABELING AS REQUIRED. 15 CABINET 12 12 12 1/2" 20/1 1.20 B 1.20 20/1 12 COORDINATE ALL REQUIREMENTS WITH LOCAL UTILITY COMPANY PRIOR TO ROUGH -IN. 12 1/2" IRECEPTACLE - SANDWICH PREP NOTE: COORDINATE EXACT TELECOM & P.O.S. 17 LIGHTS - BAR TRACK 12 (1) #2 CU GROUND IN 1 " 12 1/2" 4 O ELECTRICAL METER PER UTILITY COMPANY'S REQUIREMENTS. COORDINATE WITH UTILITY AS C 0.54 20/1 1 12 REQUIREMENTS WITH OWNER PRIOR TO 12 1/2" IRECEPTACLE - BAR CONDUIT TO 5/8" x 30'-0" CU CLAD LIGHTS - DINNING PENDANTS REQUIRED. 1 12 1 12 1/2" 20/1 ROUGH -IN. A 0.54 20/1 12 GROUND THREE POINT GROUND 12 1/2" RECEPTACLE - BATHROOMS 20 21 LIGHTS - BAR PENDANTS 12 12 #2 CU 20/1 FIELD, METALLIC WATER PIPE, B 0.50 20/1 12 12 12 1/2" KITCHEN HOOD - LIGHTS/ETC. 22 CONCRETE ENCASED ELECTRODE LIGHTS - MEZZANINE 12 12 12 1/2" 20/1 0.60 C AND BLDG STEEL. 20/1 12 12 #6 CU. GND BUILDING #2 CU STEEL #2 CU (2) 2" EMPTY CONDUIT FOR TELEPHONE/CABLE _ TV SERVICE. COORDINATE ROUTING AND EXACT TELECOM CONNECTION POINTS WITH LOCAL METALLIC WATER PIPE TELEPHONE/CABLE COMPANY CONCRETE ENCASED TELECOMMUNICATIONS RISER DIAGRAM POWER RISER DIAGRAM No Scale No Scale PANEL'PK1' LOCATION: TENANT SPACE VOLTAGE: 208Y/120V 30 4W MIN. AIC RATING: 22K AIC NOTES: PROVIDE TYPED WRITTEN DIRECTORY PROVIDE GROUND &NEUTRAL BUS TYPE: SQUARE -D MAINS: 300A ® MLO ❑ MCB MOUNTING: SURFACE FED FROM: SERVICE DISC. SW. LUGS: ❑ SUB -FEED ❑ FEED-THRU ENCLOSURE: NEMA 1 ~ CIRCUIT DESCRIPTION N o z BRANCH CIRCUITPHASE BKR LOAD KVA LOAD KVA BKR BRANCH CIRCUIT rn o z CIRCUIT DESCRIPTION r - � 0 NEUT GND COND qJ NEUT GND COND 1 LIGHTS - DINNING TRACK 12 12 12 1/2" 20/1 0.75 A 0.36 20/1 12 12 12 1/2" IRECEPTACLE - ROOF 2 3 LIGHTS - DINNING TRACK 12 12 12 1/2" 20/1 1.20 B 0.36 20/1 12 12 12 1/2" RECEPTACLE - BAR AREA 4 5 LIGHTS - DINNING TRACK 12 12 12 1/2" 20/1 1.35 1 C 0.54 20/1 12 12 12 1/2" RECEPTACLE - DINNING s 7 LIGHTS - DINNING TRACK 12 12 12 1/2" 20/1 1,35 1 A 0.54 20/1 12 12 12 1/2" RECEPTACLE - MEZZANINE 8 9 LIGHTS - DINNING TRACK 12 12 12 1/2" 20/1 1.20 B 0.74 20/1 12 12 12 1/2" RECEPTACLE - BEER FRIDGE 10 11 LIGHTS - BAR TRACK 12 12 12 1/2" 20/1 1.20 C 1 0.74 20/1 12 12 1 12 1/2" IRECEPTACLE - BEER FRIDGE 12 13 LIGHTS - BAR TRACK 12 12 12 1/2" 20/1 0.75 A 1.20 20/1 12 12 12 1/2" RECEPTACLE - ICE MACHINE 14 15 LIGHTS - BAR TRACK 12 12 12 1/2" 20/1 1.20 B 1.20 20/1 12 12 12 1/2" IRECEPTACLE - SANDWICH PREP 16 17 LIGHTS - BAR TRACK 12 1 12 1 12 1/2" 20/1 0.75 C 0.54 20/1 1 12 12 12 1/2" IRECEPTACLE - BAR 18 19 LIGHTS - DINNING PENDANTS 12 1 12 1 12 1/2" 20/1 1.40 A 0.54 20/1 12 12 12 1/2" RECEPTACLE - BATHROOMS 20 21 LIGHTS - BAR PENDANTS 12 12 1 12 1/2" 20/1 0.30 B 0.50 20/1 12 12 12 1/2" KITCHEN HOOD - LIGHTS/ETC. 22 23 LIGHTS - MEZZANINE 12 12 12 1/2" 20/1 0.60 C 0.54 20/1 12 12 12 1/2" RECEPTACLE - KITCHEN 24 25 COOLER/FREEZER DOOR/LIGHTS 12 12 12 1/2" 20/1 0.50 A 0.50 20/1 12 12 12 1/2" RECEPTACLE - GAS RANGE 26 27 COOLER/FREEZER EVAPORATOR 12 12 12 1/2"1 20/2 0.50 B /// //// - - - - SHUN TRIP 28 29 - 12 - - - - 0.50 C 0.90 20/1 12 12 1 12 1/2" CEILING FANS 30 31 COOLER/FREEZER CONDENSER 8 1 8 10 1" 40/2 2.08 A 0.90 20/1 12 12 12 12 1 CEILING FANS 32 33 - 8 1 - - - - 2.08 B - 20/1 - - - - I ISPARE 34 35 MAU-1 12 12 12 1/2" 20/1 1.22 C 0.50 1 20/1 12 12 12 1/2" EF -2 36 37 AHU-1 4 4 1 8 .25" 70/3 5.90 A 6.52 80/3 2 2 8 1.5 CU -1 38 39 - 4 - I - - - 5.90 B 6.52 2 - - - 40 41 - 4 - - - - 5.90 C 6.52 - 2 - - - 42 43 ICE MACHINE CONDENSER UNIT 10 10 10 1/2" 20/1 0.50 A 0.50 20/1 12 12 12 1/2" GWH/HWCP 44 45 SPARE - - - - 20/1 - B - 20/1 - - - - SPARE 46 47 SPARE - - - - 20/1 - C - 20/1 - - - - ISPARE 48 49 SPARE - - - -20/1 A - 20/1 - - - - ISPARE 50 51 SPARE - - - - 20/1 - B - 20/1 - - - - SPARE 52 53 SPARE - - - - 20/1 - C - 20/1 - - - - SPARE 54 EQUIPMENT SERVED CONN. LOAD L.F. D.F. DEMAND LOAD LIGHTING 12.05 KVA 125% 15.06 KVA RECEPTACLES - GENERAL 8.30 KVA ** 8.30 KVA EQUIPMENT 29.80 KVA 100% 29.80 KVA NOTES: *SPLIT A/C CONDENSING UNIT NOT INCLUDED IN LOAD CAL ** PER E6 220.44 TOTAL DEMAND LOAD: 53.16 KVA TOTAL DEMAND AMPS: 147.67 AMPS NOTE: FEEDERS ARE DESIGNED FOR A MAXIMUM VOLTAGE DROP OF 2% AT DESIGN LOAD. BRANCH CIRCUITS ARE DESIGNED FOR A MAXIMUM VOLTAGE DROP OF 3% AT DESIGN LOAD. CSC Joseph, Lawrence & Co Consulting Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG.COM CA NO. 28730 --'---1 00lllilrirrJLC 17.0258.00 N, Q�" \,\CENSE'. No. 88060 _ Blake L Suddeth �p� •. STATE OF �w� 2018.01.31 15:08:30-05'00' � .F<ORIDP..•'���� /ONA1- "11111110 Blake Lawrence Suddeth This Item hes been electronically signed and sealed by P.E. #: 69060 BlakeL. 3uddeth. PE on the Date and/or nme Stamp shown using a digital algnelure. Printed copies of this document are not cansid-d signed and sealed and the algnelure must be •••••••---• -••---»-»»-»-» ^^'»^ ^^° vsrlfed on any, electronic copies Firestop. Putty Pad (CP 617, CP 617L and CP 617XL), Product description A moldable firestop putty designed to help protect electrical outlet boxes Product features Applied by hand Fast installation Areas of application Protection of electrical outlet boxes `5 For use with• 11111 Gypsum wall assemblies with wood or metal studs Examples 'i'achin"i C0atal* CP 617' . M Where two outlets are within a single stud/cavity or within 24" dimensions (LXWXH) CP 617:6' x 7' x 1/8' (15 x 18 x 0.$ cm) CP 617L: 7' x 7" x 1/8" (18 x 18 x 03 cm) measured horizontally (not back to back unless specified by the CP 617XL 9" x911 x 1/8' (23 x 23 x 0.3 cm) specific, UL approval) ConsistencyMoldable putty , Color Red Application temperature 401F (5aC) to 95`F (35°C) Storage temperature 40-F (5"C) to 1041F (40-C) Curing time Non -curing Density 1,48 g/cma Intumescent activation Approxi 22011` to 2501F (104°C to 121 °C) Volatile solvents None Asbestos fibers None Surface burning characteristics Flame Spread: 15 (ASTM E 84.96) Smoke development: 10 Sound transmission classification 59 (Relates to specific construction) (ASTM E 90.97) Tested In accordance with + UL 263 - ASTM E 84 + ASTM G21 'At 73°F (231C) and 50% relative humidity Tars WALL OPENING PROTECTIVE FM 11 EO MATERIAL 1Yl FIRE RESISTANCE CLASSIFICATION cL us SEEPRESISTACEDIRE YIN APPROVED UL FIRE RESISTANCE DIRECTORY 66Y7 Installation instructions for CP 617 Notice stud) and completely seal against the stud within the Not for use Before handling, read Material Safety Data Sheet and stud cavity. + In areas exposed to water product label for safe usage and health Information. 3; Reshape CP 617 to fit around conduit or cables. Storage • ' Instructions below are general guidelines — always i of electrical box: 9 9 Y 4. Press CP 617 to al sides a Store only In this original packaging Ina location at refer to the applicable listing (CLIV) to the UL Fire 5. Remove other side of label. temperatures 401F (51C) to 1041F (40oC) Resistance Directory or HIM FI estop Systems Guide for complete Installation information Application of Firestop putty — ��� — — _..... 1, After ensuring box Is cleaned of loose debris, dirt, y oil, moisture, frost and wax, remove label from one ? side of pad. Fora 1 to 2 hour fire rating, one - CP 617 pad Is required. Exposed side of pad is placed against box. 1 2. CP 617 Firestop Putty Pads are to be installed to " Ir Completely Cover the exterior surfaces Of the outlet f; Rorruve label from one 2. Adhere CP 617 to 3 Reshape CP 617 to 111 4 Pres CP 817 to all 5 Remove other side box (except for the side of the outlet box against the side of CP 6t 7' ` Ouust box around box skies Of outlet bax of label HIItI Firestop Saving lives through innovation k and education ULIcUL SYSTEM NO. W -J-1020 METAL PIPE THROUGH CONCRETE WALL OR BLOCK WALL F -RATING = 2 -HR. T -RATING = 0 -HR. OR 114 -HR, L -RATING AT AMBIENT = LESS THAN 1 CFM/SQ. FT. a L -RATING AT 400°F = 4 CFMISQ. FT. FRONT VIEW SECTION A A IV A 1 A 1, CONCRETE WALL ASSEMBLY (2 -HR. FIRE -RATING): Ak LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE WALL (MIN. 5" THICK). B. ANY ULIULC CLASSIFIED CONCRETE BLOCK WALL. 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE. B. MAXIMUM 4" NOMINAL DIAMETER STEEL CONDUIT. C MAXIMUM 4" NOMINAL DIAMETER EMT. 3. MINERAL WOOL (MIN. 4 PGF DENSITY), BACKER ROD, OR HILTI CF 128 FILLER FOAM TO BE USED AS A BACKER: 4. HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT: A. MINIMUM 1/4" DEPTH WHEN EMT OR STEEL CONDUIT IS THE PENETRATING ITEM. B. MINIMUM 112" DEPTH WHEN COPPER PIPE IS THE PENETRATING ITEM. NOTES: 1. MAXIMUM DIAMETER OF OPENING = 811. 2. ANNULAR SPACE a MINIMUM 3/4", MAXIMUM 3.112" 3. FOR HOLLOW BLOCK WALLS, USE NO.8 STEEL WIRE MESH TO AID IN THE INSTALLATION. Sheet 1 of 1 Drawing No. HILTI, Inc. Scale 118" =1" WJ Tulsa, Oklahoma USA (918) 252.6000 /► FIRESTOP SYSTEMS Date SEPT. 16, 1999 1020e Saving Lives through Innovation and Education Hilti, lnce (U.S.) 1-800-879-8000 www.us.hilti.com an espahol 1.800-879-5000 • HIM Firestop Systems Gulde C)UTLET BOX\ MOUNTED N FURE RATED WALL -UL RRE RATED DETAL (W -J-1020)- SCALI=: NTS 2 SCALE: NTS STRIP IN TIETEX #272 CAULK PERIMETER W/ FLEX STITCHBOND POLYESTER SEAL SEBS (WHITE) (FABRIC WT. = 3 OZ.) SEE NOTES BELOW. 24 GA. GALV. STEEL FLASHING 12" MIN. 20" 8" MIN. �- PHOTOCELL H -0-A SELECTOR SWITCH 16" MOUNT IN NEMAII ENCLOSURE 120V CONTROL (L TWO WIRE 2P CONTROL RELAY CIRCUIT --j N ]III H II O A M COIL CLEARING CONTACTS TIME CLOCK ROOF _. L N L 1/2" CLEAR SET IRON JACK IN LIGHTING N BED OF FLEX SEAL CIRCUITS N CONDUIT L NOTES: N C CR CR C CR LATCH C CLEAR MECHANICALLY HELD LIGHTING CONTACTOR, fMOUNT IN NEMA 1 ENCLOSURE (SQ. D CLASS 8903/LXG SERIES WITH TWO WIRE FORM R6 CONTROL RELAY) WIRE CONTROL RELAY) SERIES WITH TWO WITH(ALLETWO WIRE CN BRADLEY OIES NTROL RELAY) TO LIGHTS 1. ALL SURFACES TO BE CLEAN (FREE OF DIRT, GREASE, SCALE, PAINT, ETC.) 2. WIRE BRUSH ALL LOOSE MATERIAL AS REQUIRED. 3. PRIME EXISTING ROOF AND FLASHING W/ SB ELASTOMERIC PRIMER. 4. 5 COURSE: 2 PLYS TIETEX W/ SB ELASTOMERIC GEL (FEATHER SECOND PLY) PROVIDE, INSTALL & CONNECT ADDITIONAL CONTACTS AND/OR CONTACTORS COMPLETE AT MIN. 40 MIL UNCURED PER COURSE. WITH ENCLOSURES AS REQUIRED PER APPLICATION, SEE ELECTRICAL DRAWINGS TO 5. TOP COAT W/ K-2 EXTREME DUTY ELASTOMER (MATCH ROOF COLOR) DETERMINE EXACT NUMBER OF POLES. SEE ELECTRICAL DRAWINGS FOR ACTUAL 6. DETAIL SHOW FOR WEATHERPROOFING PENETRATION ONLY. CONTRACTOR SHALL CIRCUIT NUMBERS. PROVIDE MINIMUM OF (2) ADDITIONAL/SPARE CONTACTS. PROVIDE FIRESTOPPING AS REQUIRED TO MAINTAIN FIRE RATING OF ROOF. ROOF PENETRATON CONTACTOR% TO' SCH-JEMATE tOTOCELL & TMECLOI/lICK CONTOINOLLED WEATHERPROOF DETAL PH 4 SCALE: NTS 5 SCALE: NTS \\i,ttliili,,,7 L S Ups'%,� ��,P•' 4\CENSE.' :Fjy'' No. 69060 ro Blake L Suddeth !� STATE OF LVA; 2018.01.31 15:09:09-05'00' Thl, een 9l It.. In., bwt—icplly sIgnnd and sealed by flak. l.. guddelh, PE on in. MI. and/or 71- Stamp ah.- o,lM , dlgllal tlgnalura. Printed wpi., orthl, goon W are not conaldered signed and atalad and the eget . mug ba yedaed an any elechonk cople, Joseph, Lawrence & Co Consultinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCENG.COM CA NO. 28730 JLC 17.0258.00 Blake Lawrence Suddeth P.E. #: 69060 3 4 2 .r r.._Z VIA A 1, CONCRETE WALL ASSEMBLY (2 -HR. FIRE -RATING): Ak LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE WALL (MIN. 5" THICK). B. ANY ULIULC CLASSIFIED CONCRETE BLOCK WALL. 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE. B. MAXIMUM 4" NOMINAL DIAMETER STEEL CONDUIT. C MAXIMUM 4" NOMINAL DIAMETER EMT. 3. MINERAL WOOL (MIN. 4 PGF DENSITY), BACKER ROD, OR HILTI CF 128 FILLER FOAM TO BE USED AS A BACKER: 4. HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT: A. MINIMUM 1/4" DEPTH WHEN EMT OR STEEL CONDUIT IS THE PENETRATING ITEM. B. MINIMUM 112" DEPTH WHEN COPPER PIPE IS THE PENETRATING ITEM. NOTES: 1. MAXIMUM DIAMETER OF OPENING = 811. 2. ANNULAR SPACE a MINIMUM 3/4", MAXIMUM 3.112" 3. FOR HOLLOW BLOCK WALLS, USE NO.8 STEEL WIRE MESH TO AID IN THE INSTALLATION. Sheet 1 of 1 Drawing No. HILTI, Inc. Scale 118" =1" WJ Tulsa, Oklahoma USA (918) 252.6000 /► FIRESTOP SYSTEMS Date SEPT. 16, 1999 1020e Saving Lives through Innovation and Education Hilti, lnce (U.S.) 1-800-879-8000 www.us.hilti.com an espahol 1.800-879-5000 • HIM Firestop Systems Gulde C)UTLET BOX\ MOUNTED N FURE RATED WALL -UL RRE RATED DETAL (W -J-1020)- SCALI=: NTS 2 SCALE: NTS STRIP IN TIETEX #272 CAULK PERIMETER W/ FLEX STITCHBOND POLYESTER SEAL SEBS (WHITE) (FABRIC WT. = 3 OZ.) SEE NOTES BELOW. 24 GA. GALV. STEEL FLASHING 12" MIN. 20" 8" MIN. �- PHOTOCELL H -0-A SELECTOR SWITCH 16" MOUNT IN NEMAII ENCLOSURE 120V CONTROL (L TWO WIRE 2P CONTROL RELAY CIRCUIT --j N ]III H II O A M COIL CLEARING CONTACTS TIME CLOCK ROOF _. L N L 1/2" CLEAR SET IRON JACK IN LIGHTING N BED OF FLEX SEAL CIRCUITS N CONDUIT L NOTES: N C CR CR C CR LATCH C CLEAR MECHANICALLY HELD LIGHTING CONTACTOR, fMOUNT IN NEMA 1 ENCLOSURE (SQ. D CLASS 8903/LXG SERIES WITH TWO WIRE FORM R6 CONTROL RELAY) WIRE CONTROL RELAY) SERIES WITH TWO WITH(ALLETWO WIRE CN BRADLEY OIES NTROL RELAY) TO LIGHTS 1. ALL SURFACES TO BE CLEAN (FREE OF DIRT, GREASE, SCALE, PAINT, ETC.) 2. WIRE BRUSH ALL LOOSE MATERIAL AS REQUIRED. 3. PRIME EXISTING ROOF AND FLASHING W/ SB ELASTOMERIC PRIMER. 4. 5 COURSE: 2 PLYS TIETEX W/ SB ELASTOMERIC GEL (FEATHER SECOND PLY) PROVIDE, INSTALL & CONNECT ADDITIONAL CONTACTS AND/OR CONTACTORS COMPLETE AT MIN. 40 MIL UNCURED PER COURSE. WITH ENCLOSURES AS REQUIRED PER APPLICATION, SEE ELECTRICAL DRAWINGS TO 5. TOP COAT W/ K-2 EXTREME DUTY ELASTOMER (MATCH ROOF COLOR) DETERMINE EXACT NUMBER OF POLES. SEE ELECTRICAL DRAWINGS FOR ACTUAL 6. DETAIL SHOW FOR WEATHERPROOFING PENETRATION ONLY. CONTRACTOR SHALL CIRCUIT NUMBERS. PROVIDE MINIMUM OF (2) ADDITIONAL/SPARE CONTACTS. PROVIDE FIRESTOPPING AS REQUIRED TO MAINTAIN FIRE RATING OF ROOF. ROOF PENETRATON CONTACTOR% TO' SCH-JEMATE tOTOCELL & TMECLOI/lICK CONTOINOLLED WEATHERPROOF DETAL PH 4 SCALE: NTS 5 SCALE: NTS \\i,ttliili,,,7 L S Ups'%,� ��,P•' 4\CENSE.' :Fjy'' No. 69060 ro Blake L Suddeth !� STATE OF LVA; 2018.01.31 15:09:09-05'00' Thl, een 9l It.. In., bwt—icplly sIgnnd and sealed by flak. l.. guddelh, PE on in. MI. and/or 71- Stamp ah.- o,lM , dlgllal tlgnalura. Printed wpi., orthl, goon W are not conaldered signed and atalad and the eget . mug ba yedaed an any elechonk cople, Joseph, Lawrence & Co Consultinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCENG.COM CA NO. 28730 JLC 17.0258.00 Blake Lawrence Suddeth P.E. #: 69060 MAF RTU AHU EXHAUST FAN � -- DISCONNECT SWITCH WITH SHUTDOWN POWER TO HOOD EXHAUST RELAY, TYPICAL F/ FAN NOTON SHUNT TRIP _ .,..._ i RTU DUCT SMOKE CIRCUIT BREAKERS OR CONTACTORS i ^ DETECTOR - --� _r I � �., W VOLTAGE SIGNAL TO MA TO BUILDING FIRE .:_....�...�.�..�... -_ SHUTDOWN (IF NO BUILDING ALARM (IF LOW VOLTAGE SIGNAL TO HEAT DETECTOR FOR i FIRE ALARM SYSTEM) APPLICABLE) RTU/AHU SHUTDOWN (IF NO EQUIPMENT ACTIVATION , , L----------- --------------- -----, �------------------------------� BUILDING FIRE ALARM SYSTEM) '------------------------------------------------- --- --------------- ------------------- J✓.... HEAT DETECTOR FUSIBLE ----=-------=------------- , MECHANICAL LINKAGE LINK SUPPLIED BY HOOD TO SHUNT TRIPS OR CONTRACTOR i ' _ LOW VOLTAGE FAN/LIGHT I ; I CONTACTORS FOR CONTROL WIRING 1 ELECTRICAL EQUIPMENT HOOD -------- -- ,------------=------------ -----, MECHANICAL LINKAGE ------ ------------------ --------------------- i----- ----------------- 1I , MECHANICAL 1 1 MECHANICAL LINKAGE ;-- ---� 1 GAS VALVE 0 o I HOOD ° TOBUILDING FIRE ALARM HOOD Z SUPPLIED CONTROL BY HOOD CONTROL (IF APPLICABLE) SYSTEM PANEL - ---- CONTRACTOR 10 ° PANEL POWER TO EQUIPMENT ° MANUAL PULL ELECTRICAL OUTLET UNDER HOOD ON SHUNT i STATION UNDER HOOD, REFER ' ` EQUIPMENT TRIP CIRCUIT BREAKERS OR F TO FLOOR PLANS FOR UNDER HOOD CONTACTORS REQUIREMENTS --------------------------------------------------------------------------------- "' r ✓ r" !' / ;' r V r ✓ f '" i.✓ er f. r F A, J F /.:. r' f / J r F " ... .. ..., ......r. ..,r.....,... ✓.,.,,_._... .... ..."_.. ............/..».,r.,..,r._�(,,:..d».....(.:,.,r'.`.,"..,c»..!"»r". f, .. 1,.» ,...,.,,l..._f r .✓.._e ..r .. r_... ....».,, r. ,.s,_...., SEQUENCE OF OPERA7ONS 1. THE FUSIBLE LINK WITHIN THE EXHAUST DUCT WORK WILL BLOW OR THE MANUAL PULL STATION IS ACTIVATED. NOTES: 2. THE ANSUL SYSTEM WILL BE ACTIVATED CAUSING THE FOLLOWING; 1. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO A. A SIGNAL WILL BE SENT TO THE BUILDING FIRE ALARM. (IF APPLICABLE) PROVIDE ALL LOW VOLTAGE WIRING AND TO INTERCONNECTING B. A SIGNAL WILL BE SENT TO ELECTRICAL SHUNT TRIP BREAKERS OR CONTACTORS (ALL ELECTRICAL THE HOOD ANSUL SYSTEM WITH THE SHUNT TRIP BREAKERS OR EQUIPMENT ASSOCIATED WITH THE HOOD SYSTEM WILL SHUTDOWN). CONTACTORS, THE BUILDING FIRE ALARM SYSTEM, AND ANY C. GAS ANSUL VALVE WILL CLOSE (NORMALLY OPEN). HOOD CONTROL PANELS. (IF APPLICABLE) 3. THE HOOD EXHAUST FAN WILL REMAIN IN OPERATION. 4. THE ANSUL SYSTEM GAS BOTTLES WILL DISCHARGE. 2. WHEN FIRE ALARM SYSTEM IS ACTIVATED ALL UNDER HOOD 5. RTU/AHU SYSTEMS WILL SHUTDOWN UPON DETECTION OF SMOKE VIA DUCT SMOKE DETECTOR OR FROM A EQUIPMENT SHALL BE SHUT DOWN. THE HOOD EXHAUST FANS SHUTDOWN SIGNAL FROM THE BUILDING FIRE ALARM SYSTEM OR HOOD CONTROL PANEL. SHALL REMAIN ACTIVE. CSC Josep%, Lawrence & Co Consulting Engineeps 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCEHG.COM CA NO. 28730 MOOD CONTROL SCHEMATE DETAL _ _ II. SUp �`�JLC 17.0258.00 u SCALE- NTS 4 P cENs •:Fj; No. 69060 Blake L Suddeth A©'. STATE OF (V�� 2018.01.31 15:09:32-05'00' C" 11110\\ ,NAt.0\\`��� ThleItem has bean electronically signed and sealed by. Blake Lawrence Suddeth Bleka l 8uddeth, PE on the Date and/.r ltma Stampshown osing a digital sYgnatum. Printed tropias of this document ars P. E. #: 69060 not considered algnod end sealed and the signature must be 1.116.d an any elaaM jd a.pj.o DETAILS - ELECTRICAL SULLIVAN'S PUBLIC HOUSE 116 E FIRST STREET SANFORD, FL 32771 100% CDs MILZARCH, LLC 01/31/18 JERRY WALKER MILLS, SR. 407.921.8795 MILZARCH GMAIL.COM SHEET AR0008314 E5.2 701 WEST Third Street, Sanford, Fl. 32771 PATES 84/7011 SEAL ELECTRICAL SPECIFICATIONS STALLED IN ACCORDANCE WITH THE NATIONAL I. GENERAL REQUIREMENTS: J. THE ELECTRICAL CIRCUITS,: COMPONENTS, AND CONTROLS FOR ALL EQUIPMENT ARE SELECTED AND F. MOUNTING HEIGHTS ARE APPROXIMATE. THE EXACT LOCATIONS .AND MOUNTING HEIGHTS SHALL BE B. ALL GROUNDING CONNECTIONS SHALL BE INSUCH CODES SHALL BE CONSIDERED DETERMINED ON THE JOB AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH ELECTRICAL CODE AND ALL LOCAL CODES AND REQUIREMENTS. S SIZED, BASED ON .THE EQUIPMENT SPECIFIED. IF SUBSTITUTIONS AND/OR EQUIVALENT EQUIPMENT. ARE D THE INSTALLATION OF THE GROUNDING SYSTEM COMPLIANCE WITH THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING ALL TRADES TO INSURE CORRECT INSTALLATION I.E. OVER COUNTERS IN OR ABOVE BACK -SPLASHES, MINIMUM REQUIREMENTS AN A. DO ALL WORK N FURNISHED, IT .SHALL BE THE RESPONSIBILITY OF ALL PARTIES CONCERNED, .INVOLVED IN, AND � � SHALL INSURE FREEDOM FROM DANGEROUS SHOCK EXPOSURE AND SHALL PROVIDE A LOW CODE FBC-2017 , NFPA 70 NEC -2014 AND NFPA 101 (LIFE SAFETY CODE -2015), FURNISHING THE SUBSTITUTE AND/OR EQUIVALENT EQUIPMENT TO VERIFY AND COMPARE THE IN BLOCK WALLS, TILE, AND OTHER SPECIFIC CONSTRUCTION FEATURES. LOCATION OF OUTLETS R NT AND GROUND FAULT AND THE REGULATIONS OF THE LOCAL UTILITY TELEPHONE, CABLE TELEVISION AND POWER UTILITY / MOUNTED IN BUILT-INS, MILLWORK, AND CABINETRY SHALL BE VERIFIED. OUTLETS MOUNTED IN KICK IMPEDANCE GROUND FAULT PATH TO PERMIT OPERATION OF OVERCUR E ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF THAT FURNISHED TO THAT SPECIFIED AND/OR COMPANIES. OBTAIN AND PAY FOR ANY AND ALL REQUIRED PERMITS, INSPECTIONS, SHOWN. IF GREATER CAPACITY OR MORE MATERIALS OR LABOR IS REQUIRED FOR THE ROUGH -IN, OR TOE SPACES SHALL BE MOUNTED HORIZONTALLY. OUTLET BOXES SHALL BE MOUNTED TO PROTECTIVE DEVICES: CERTIFICATES OF INSPECTIONS AND APPROVAL AND THE LIKE, AND DELIVER SUCH CERTIFICATES PREVENT DEVICE PLATE FROM OVERLAPPING BACKSPLASH, TRIM, TILE, ETC. LOCATE SO DEVICE PLATE CIRCUITRY OR CONNECTIONS THAN FOR THE ITEM SPECIFIED AND PROVIDED FOR, THEN IT SHALL BE C. ALL SERVICE AND EQUIPMENT GROUNDING CONDUCTORS, AND BONDING JUMPERS SMALL BE TO THE ENGINEER. THE RESPONSIBILITY OF THE PARTIES INVOLVED IN PROVIDING THE SUBSTITUTE AND/OR EQUIVALENT WILL LAY FIAT AGAINST SURFACE COMPLETELY AROUND THE PERIMETER OF PLATE. THHN THWN OR THW CONDUCTORS UNLESS NOTED OTHERWISE AND / INSULATED COPPER, TYPE � ( ) ITEMS OF EQUIPMENT TO PROVIDE ALL COMPENSATION FOR ADDITIONAL CHARGES MADE FOR THE SHALL BE SIZED IN ACCORDANCE WITH THE APPLICABLE PORTIONS OF ARTICLES 250 AND 517 OF PROVIDE ALL LABOR INCLUDING _ G. OUTLETS, OTHER THAN THOSE COORDINATED WITH COUNTER TOPS, SHELVES, AND CABINETS, B. THE CONTRACTOR SHALL FURNISH, PERFORM, OR OTHERWISE RO E ( PROPER ROUGH IN, CIRCUITRY AND CONNECTIONS FOR THE EQUIPMENT FURNISHED. NO ADDITIONAL CONDUCTORS 6 AWG AND SMALLER SHALL HAVE A INC HOISTING, SHALL BE LOCATED WITH THE CENTER LINE -0F OUTLET BOXES THE FOLLOWING DISTANCE ABOVE THE THE NATIONAL ELECTRICAL CODE. GROUNDING COND # BUT NOT LIMITED. T0, ALL PLANNING, PURCHASING, PAINTING, TRANSPORTING, RIGGING, G, CHARGES ABOVE THE BASE BID SHALL BE ALLOWED FOR SUCH REVISIONS. STORING, INSTALLING, TESTING CHASING CHANNELING CUTTING TRENCHING EXCAVATING ANDFINISHED FLOOR, UNLESS OTHERWISE INDICATED: GREEN COLOR INSULATION. ALL GROUNDING CONDUCTORS #4 AWG AND LARGER SHALL BE BACKFILLING), COORDINATION, FIELD VERIFICATION, EQUIPMENT INSTALLATION, SUPPORT, AND K. EXCAVATION FOR UNDERGROUND ELECTRICAL STRUCTURES. CONFORM TO ELEVATIONS AND „ ADEQUATELY IDENTIFIED WITH A GREEN TRACER AND/OR GREEN COLORED TAPE AT EACH END OF SAFETY SUPPLIES AND MATERIALS NECESSARY FOR THE CORRECT INSTALLATION OF COMPLETE SUFFICIENT 1. RECEPTACLES, GENERAL: 1 -6 AFF THE GROUNDING CONDUCTOR AND AT EACH PULLBOX OR OTHER ACCESSIBLE LOCATION. SAFETY, � DIMENSIONS SHOWN WITHIN A TOLERANCE OF PLUS OR MINUS 0.10 ; PLUS A SU AND FUNCTIONAL ELECTRICAL SYSTEMS (AS DESCRIBED OR IMPLIED BY THESE SPECIFICATIONS DISTANCE TO PERMIT PLACING AND REMOVAL OF CONCRETE FORMWORK, INSTALLATION OF 2. TELEPHONE OUTLETS: 1 ,- 6„ AFF ITEMS SERVICES OTHER CONSTRUCTION D. THE MAIN SERVICE GROUNDING. ELECTRODE SYSTEM SHALL CONSIST OF THE .FOLLOWING AND THE APPLICABLE DRAWINGS). , AND FOR INSPECTION. 3. SWITCHES, GENERAL: 4'-0" AFF BONDED TOGETHER BY THE GROUNDING ELECTRODE CONDUCTORS IN ACCORDANCE WITH NEC ARTICLE C. ALL DRAWINGS AND SPECIFICATIONS ON THE PROJECT ARE COMPLEMENTARY, EACH TO ALL OTHER L. TRENCHING: EXCAVATE TRENCHES FOR ELECTRICAL INSTALLATIONS AS FOLLOWS. V. RACEWAYS 250, PART H: SETS, AND THEY SHALL BE USED IN COMBINATION FOR THE EXECUTION OF THIS WORK. - NEC 250_ IF METAL81(A) THE MAIN UNDERGROUND COLD WATER PIPE, , , DIVISION 16 WORK SHOWN ON ANY ONE SET OF DRAWINGS, INCLUDING ALL ARCHITECTURAL 1. EXCAVATE TRENCHES TO THE UNIFORM .WIDTH, SUFFICIENTLY. WIDE TO PROVIDE AMPLE A. SHALL BE GALVANIZED OUTSIDE AND INSIDE BY HOT DIPPING. E.M.T. SHALL BE ELECTRO- _ PROTECTION DRAWINGS FOR GENERAL WORK AND GALVANIZED. CONDUITS SHALL BE AS MANUFACTURED BY REPUBLIC, PITTSBURGH STANDARD, 2. METAL FRAME OF BUILDING WHERE AVAILABLE, NEC 250-81(B) DRAWINGS, MECHANICAL, PLUMBING AND FIRE PROTE WORKING ROOM AND A MINIMUM OF 6 TO 9 .CLEARANCE ON BOTH SIDES OF RACEWAYS WHIATLAND TRIANGLE ALLIED OR YOUNGSTOWN. 3. CONCRETE ENCASED ELECTRODE, NEC 250-81(C) EQUIPMENT, AND DIVISION 16 WORK CALLED FOR UNDER ANY SECTION OF THE PROJECT AND EQUIPMENT. a , SPECIFICATIONS, SHALL BE CONSIDERED AS INCLUDED IN THIS WORK UNLESS SPECIFICALLY 2. EXCAVATE TRENCHES TO DEPTH INDICATED OR REQUIRED. 4. THE BUILDING LIGHTNING PROTECTION SYSTEM. EXCLUDED BY INCLUSION IN SOME OTHER BRANCH OF THE WORK. THIS SHALL INCLUDE 3. LIMIT THE LENGTH OF OPEN TRENCH TO THAT IN WHICH INSTALLATIONS CAN. BE MADE AND. B. SHALL BE STANDARD THREADED TYPE, GALVANIZED OUTSIDE AND INSIDE BY HOT DIPPING ROUGHING -IN FOR CONNECTIONS AND EQUIPMENT AS CALLED FOR OR INFERRED. . THE THE TRENCH BACKFILLED WITHIN THE SAME DAY. THREADLESS AND CLAMP TYPE NOT ACCEPTABLE. SHALL BE AS MANUFACTURED BY RACO, E. THE NEUTRAL CONDUCTOR SHALL BE GROUNDED AT THE SERVICE ENTRANCE MAIN DISCONNECT, CONTRACTOR SHALL CHECK ALL DRAWINGS AND SPECIFICATIONS FOR THE PROJECT AND SHALL BE 4. WHERE ROCK IS ENCOUNTERED, CARRY EXCAVATION BELOW REQUIRED ELEVATION AND EFCOR, OR APPLETON. AND AT EACH SEPARATELY DERIVED SYSTEM ONLY PER NEC ARTICLE 250. RESPONSIBLE FOR THE INSTALLATION OF ALL DIVISION 16 WORK. BACKFILL WITH A LAYER OF CRUSHED STONE OR GRAVEL PRIOR TO INSTALLATION OF �� C. SHALL BE STEEL THREADED COMPRESSION TYPE. ALL COUPLINGS AND CONNECTORS. SHALL BE F. A 4 INSULATED COPPER CONDUCTOR INSTALLED IN 3/4" CONCEALED CONDUIT SHALL BE RACEWAYS AND EQUIPMENT. PROVIDE A MINIMUM OF 6 OF STONE OR GRAVEL CUSHION # THE CONTRACTOR SHALL CAREFULLY CHECK THE DRAWINGS AND SPECIFICATIONS OF ALL OTHER EFCOR OR RACO. PRESSURE INDENTED TYPE CONNECTORS OR CAST METAL WILL NOT BE APPROVED CONNECTED FROM. THE BUILDING GROUNDING ELECTRODE SYSTEM TO EACH BUILDING TELEPHONE D. .BETWEEN ROCK BEARING SURFACE AND ELECTRICAL INSTALLATIONS. TRADES AND DIVISIONS BEFORE INSTALLING ANY OF HIS WORK. HE SHALL IN ALL CASES FOR ANY LOCATION. TERMINAL/DATA IDF TERMINAL BOARDS, OR CABINETS, FIRE ALARM CONTROL CABINETS, CCN SYSTEM WORK OF ALL OTHER TRADES AND SHALL COORDINATE HIS WORK WITH THEM SO CABINETS, EMS CABINETS, AND SECURITY SYSTEM CABINETS. TERMINATE ON AN APPROPRIATELY SIZED CONSIDER THE M. THE CONTRACTOR SHALL PROVIDE ALL INSERTS FOR THE SUPPORT OF DIVISION 16 THAT THE BEST ARRANGEMENTS OF ALL EQUIPMENT, PIPING, CONDUIT, DUCTS, ROUGH -IN, ETC., L CONCRETE OR THROUGH CONCRETE SLABS AS CONSTRUCTION D. CONNECTORS SHALL HAVE PLASTIC INSULATED THROAT INSERTS. 8 TERMINAL MULTI -CONDUCTOR CONNECTION GROUNDING LUG LOCATED WITHIN CABINET OR ON EQUIPMENT TO BE PLACED N ( ) CAN BE OBTAINED. PROGRESSES. HE SHALL PROVIDE ALL MISCELLANEOUS HANGING AND SUPPORTING HARDWARE. ALL TERMINAL BOARDS. ELECTRICAL WORK IS TO BE CONCEALED IN OR .BUILT INTO GENERAL CONSTRUCTION SHALL BE E. THE .USE OF METAL CLAD CABLE IS ACCEPTABLE IN LOCATIONS AS ACCEPTED BY .THE NEC AND E. LOCATIONS DESIGNATED FOR OUTLETS, SWITCHES, DEVICES, EQUIPMENT, ETC., ARE 0 ALL LOCAL JURISDICTIONAL CODES. IX. PANELBOARDS: PLACED AS CONSTRUCTION STRU TION PROGRESSES. FAILURE OF THE CONTRACTOR TO COORDINATE WORK WITH C APPROXIMATE ` AND FINAL LOCATIONS SHALL BE VERIFIED IN THE FIELD. CONTRACTOR SHALL OTHER TRADES AND THE PROJECT CONSTRUCTION PROGRESS SHALL. MAKE HIM RESPONSIBLE FOR F. STEEL `METAL CLAD CABLE, TYPE MC, EMPLOYING CIRCUIT CONDUCTORS #12 SOLID TO #2 AWG, LOCATE ALL .DEVICES UP TO 5 FEET IN ANY DIRECTION. AS DIRECTED BY OWNER AND PER CODE. ALL COST OF CUTTING AND PATCHING, AS REQUIRED TO INSTALL WORK: NO STRUCTURAL MEMBER,. A. PANELBOARDS SHALL BE DEAD FRONT TYPE .AND SHALL BE IN ACCORDANCE WITH UNDERWRITERS INSUFFICIENT TO CONVEY THE INTENT OF THE DESIGN SOLID OR STRANDED COPPER WITH THHN INSULATION, AN INSULATED GREEN GROUNDING CONDUCTOR RD ENCLOSING CABINETS AND SO LABELED: WHERE INSTRUCTIONS OR NOTES ARE� MASONRY CONSTRUCTION OR FINISHED WORK .SHALL BE CUT OR ALTERED WITHOUT. PRIOR WRITTEN LABORATORIES, INC., STANDARD FOR PANELBOARDS AND THE OWNER PRIOR TO BIDDING AND INSTALLATION. AND GALVANIZED STEEL INTERLOCKED ARMOR CLADDING. THE CABLES SHALL BE SUITABLE FOR USE CONSULTAPPROVAL BY THE ARCHITECT/ENGINEER. CONTRACTOR SHALL FIRE RATE ALL. PENETRATIONS THROUGH ALL FIRE RATED SLABS OR WALLS PER THE INTENDED RATING. IN DRY LOCATIONS AT TEMPERATURES NOT EXCEEDING 90' C ON AD CIRCUITS UP TO 600 VOLTS IN B. PANELBOARDS SHALL BE FACTORY ASSEMBLED WITH BRANCH BREAKERS ARRANGED AS SHOWN IN ACCORDANCE WITH N.E.C., ARTICLE 334. THE CABLE SHALL BE ONE AND TWO HOUR FIRE RATED PER F. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING AND COORDINATING THE LOCATIONS OF SCHEDULES: BREAKERS SHALL BE NUMBERED VERTICALLY BEGINNING TOP LEFT. BREAKER NUMBERS DEVICES TO BE USED AND COORDINATING THE FINAL LOCATIONS SOF ELECTRICAL EQUIPMENT WITHN. THE CONTRACTOR SHALL SUPPLY AND SET INTO PLACE ALL WALL SLEEVES FOR CONDUITS ANSI/UL 1479 FOR USE IN WALL, CEILING AND FLOOR ASSEMBLIES. SHALL BE PERMANENTLY ATTACHED TO TRIM. PANEL SHALL BE MINIMUM 20" WIDE OR 16" FOR MILLWORK, SINKS, BENCHES, COUNTERS AND SHELVING PRIOR TO BIDDING AND INSTALLATION. AND CEILING INSERTS FOR HANGERS IN AREAS OF NEW CONSTRUCTION AS BUILDING CONSTRUCTION RESIDENTIAL LOAD CENTERS, UNLESS SPECIFICALLY NOTED OTHERWISE: ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. PROGRESSES. INSTALL EQUIPMENT NOTED TO BE CONCEALED IN WALLS BEFORE WALLS ARE G. FLEXIBLE METALLIC CONDUIT RACEWAYS MAY BE USED TO CONNECT HVAC UNITS LOCATED IN CONSTRUCTED IN ORDER THAT WALLS MAY BE CONSTRUCTED AROUND CONDUITS, ENCLOSURES, ETC. INTERIOR MECHANICAL AREAS. MINIMUM SIZE 3/4". C. ANY SPECIAL REQUIREMENTS ON THE DRAWINGS OR SCHEDULES, SUCH AS GROUND FAULT G. DIVISION 16 CONTRACTOR SHALL HAVE HAD EXPERIENCE OF AT LEAST THE SAME SIZE AND PROTECTION, ARC -FAULT CIRCUIT BREAKERS, INCREASED INTERRUPTING CAPACITY, SHUNT TRIP TYPE SCOPE AS THIS PROJECT, ON AT LEAST TWO OTHER PROJECTS WITHIN THE LAST FIVE YEARS IN 0. METALLIC MATERIALS SHALL BE PROTECTED AGAINST CORROSION. EQUIPMENT ENCLOSURES SHALL H. CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL CODE EXCEPT CIRCUIT BREAKER, FEED THRU PANELBOARDS, ETC., SHALL SUPERSEDE THESE SPECIFICATIONS, BUT ORDER TO BE QUALIFIED TO BID THIS PROJECT. BE GIVEN RUST -INHIBITING TREATMENT AND STANDARD FINISH BY MANUFACTURER. ALUMINUM SHALL THAT NO CONDUIT SHALL BE SMALLER THAN 3/4" UNLESS OTHERWISE NOTED. CONDUIT SHALL BE ONLY INSOFAR AS THAT PARTICULAR REQUIREMENT IS CONCERNED AND AS INDICATED. H. CONTRACTOR SHALL AND DOES HEREBY WARRANT ALL MATERIALS AND EQUIPMENT FURNISHED NOT BE USED ON CONTACT WITH EARTH, AND, WHERE CONNECTED TO DISSIMILAR METAL, SHALL BE SIZED LARGER THAN REQUIRED ABOVE WHEN SO SHOWN ON THE DRAWINGS OR WHEN REQUIRED BY PROTECTED BY SUITABLE FITTINGS AND TREATMENT. ALL FERROUS METALS SUCH AS ANCHORS, LOCAL CODE. D. WIRING IN PANELBOARD GUTTERS SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. WIRING UNDER THIS SECTION OF THE SPECIFICATIONS TO FREE FROM DEFECTS AND FUNCTION BOLTS, BRACES, BOXES, BODIES, CLAMPS, FITTINGS, GUARDS, NUTS, PINS, RODS, SHIMS, THIMBLES, SHALL BE GROUPED INTO NEAT BUNDLES AND SECURED WITH NYLON TIE WRAPS. OPERATE SATISFACTORILY FOR ONE YEAR AFTER FINAL L ACCEPTANCE OF THE WORKK,, AND THAT ANY WASHERS, AND MISCELLANEOUS PARTS, NOT OF STAINLESS STEEL OR NONFERROUS MATERIALS, I. ANY CONDUIT STUBBED OUT FOR FUTURE SHALL BE CAPPED WITH A PLASTIC CAP AND MARKED ITEMS NOT MEETING THIS REQUIREMENT WILL BE MADE GOOD BY HIM WITHOUT COST TO SHALL BE HOT -DIPPED GALVANIZED. WITH A 2" MINIMUM RED METAL TAG WHICH IDENTIFIES CONDUIT ORIGIN. CONDUITS STUBBED UP E. PROVIDE TYPE WRITTEN DIRECTORIES FOR EACH PANELBOARD INDICATING THE LOAD SERVED. OWNER, PROVIDED SUCH DEFECTS OR FAILURES ARE NOT DUE TO ABUSE, NEGLECT, OR LACK OF ABOVE GRADE OR ROOF SHALL BE TAGGED ON THE CONDUIT. CONDUIT STUBBED OUT BELOW GRADE REASONABLE AND ORDINARY MAINTENANCE. P. ALL CONDUITS STUBBED OUT FOR FUTURE USE SHALL HAVE A PULL WIRE INSTALLED, A PLASTIC SHALL BE TAGGED ON NEAREST BUILDING WALL, CURB, ETC., DIRECTLY OVER THE CONDUIT RUN. ALL X. LIGHTING FIXTURES: L ALL WORK SHALL BE EXECUTED IN A WORKMANSHIP MANNER DISPLAYING A NEAT CAP INSTALLED AND BE IDENTIFIED AS TO THE CONDUIT ORIGIN. EMPTY CONDUITS SHALL HAVE PULL WIRES. A. LIGHTING FIXTURES SHALL BE FURNISHED AS SHOWN ON DRAWINGS AND IN THE .LIGHTING MECHANICAL APPEARANCE UPON COMPLETION. Q. THE RESPONSIBILITY FOR ANY CUTTING OF CONSTRUCTION WHICH IS REQUIRED FOR THE VI, SCHEDULE 40 RIGID PVC: FIXTURE SCHEDULE. IT SHALL SPECIFICALLY BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY INSTALLATION OF DIVISION 16 WORK, SHALL BE BY THE CONTRACTOR. THE CONTRACTOR SHALL EXACT TYPE CEILING AND RECESSING DEPTH OF ALL RECESSED FIXTURES AND TO FURNISH THE J. BALANCE TOTAL PHASE LOADS IN EACH ELECTRICAL PANEL TO A VALUE WITHIN 10% OF EACH COORDINATE WITH ALL OTHER TRADES AND THE OWNER BEFORE ANY CUTTING AND OBTAIN APPROVAL A. CONDUIT SHALL BE COMPOSED OF POLYVINYLCHLORIDE AND SHALL BE UL RATED TYPE 40 FOR MOUNTING TRIMS AND ACCESSORIES OF THE SPECIFIED AND/OR APPROVED FIXTURES FOR THE OTHER. FROM THE ARCHITECT/ENGINEER PRIOR TO ANY CUTTING. ALL PATCHING AND FINISHING SHALL BE BY USE WITH 90EC RATED CONDUCTORS. CONDUIT SHALL CONFORM TO NEMA STANDARDS AND CEILING TO BE INSTALLED. LIGHTING FIXTURES SHALL BE PROVIDED WITH JOINER PLATES, END CAPS, K. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION, WHEREVER WORK IS TO BE THE CONTRACTOR. APPLICABLE SECTIONS OF NEC. RETAINING CLIPS, PLASTER FRAMES, HOUSINGS, AND ALL OTHER ACCESSORIES REQUIRED FOR A PERFORMED IN FINISHED OCCUPIED SPACES, TO PREVENT DAMAGE TO ADJACENT AREAS, COMPLETE INSTALLATION. / R. WHERE OPENINGS OR HOLES ARE CUT IN CONSTRUCTION AND THE CUTTING BREAKS ELECTRICAL B. INSTALLATION OF RIGID NON-METALLIC CONDUIT SHALL COMPLY WITH ARTICLE 347 OF THE EQUIPMENT, OR FURNISHINGS; TO PREVENT ACCIDENTAL INJURY TO BUILDING OCCUPANTS AND CIRCUITRY OR CONTROL CIRCUITRY CONDUIT AND WIRING, THEN IT SHALL BE THE RESPONSIBILITY OF NATIONAL ELECTRICAL CODE (NFPA 70) AND THESE SPECIFICATIONS. B. ALL FIXTURES SHALL BE EQUIPPED WITH LAMPS UNLESS OTHERWISE NOTED. LAMPS SHALL BE THE PUBLIC; TO PREVENT THE SPREADING OF DUST, DIRT, DEBRIS, AND MOISTURE FROM THE THE CONTRACTOR TO REROUTE THE CIRCUITRY CONDUIT AND REWIRING AND TO COMPLETE THE INSTALLED NEW, IMMEDIATELY PRIOR TO FINAL INSPECTION, AND SHALL NOT BE USED FOR AREA WHERE WORK IS BEING PERFORMED; AND TO PREVENT DUST, DIRT, DEBRIS, AND CIRCUITRY AS REQUIRED AND AS APPROVED BY THE ARCHITECT/ENGINEER. TEMPORARY COMPLETION C. PROVIDE A CONTINUOUS, INSULATED, GROUNDING CONDUCTOR IN EVERY RIGID, NON-METALLIC CONSTRUCTION. MOISTURE FROM GETTING ON OR IN THE BUILDING OCCUPANT'S FURNISHINGS OR EQUIPMENT. SHALL BE PROVIDED WHERE NECESSARY BEFORE THE PERMANENT REROUTING AND COMPLETION RACEWAY EVEN IF NOT SHOWN ON THE DRAWINGS. THE GROUNDING CONDUCTOR SHALL BE WORK IS FINISHED: CONNECTED TO GROUND AT EACH END OF THE RACEWAY IN ACCORDANCE WITH ARTICLE 250 OF C. FIXTURE CATALOG NUMBER REPRESENTS BASIC LUMINARY SIZE, TYPE, QUALITY AND L. THE CONTRACTOR SHALL REPAIR, AT NO COST TO THE OWNER ANY DAMAGE DONE BY HIMSELF THE NATIONAL ELECTRICAL CODE (NFPA 70). CONFIGURATION. ACCESSORIES SHALL BE FURNISHED WITH EACH UNIT AS REQUIRED FOR A COMPLETE OR HIS EMPLOYEES: HE SHALL ALSO BE RESPONSIBLE FOR ALL CUTTING AND PATCHING S. ANY PENETRATIONS OF FIRE OR SMOKE RATED ASSEMBLIES MADE BY THIS CONTRACTOR IN FINISHED INSTALLATION. BASIC ACCESSORIES SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE REQUIRED TO PROPERLY INSTALL HIS WORK. THIS SHALL ALSO INCLUDE THE PATCHING OF EXISTING VERTICAL OR HORIZONTAL CONSTRUCTION SHALL BE SEALED AND PROTECTED BY THIS CONTRACTOR D. WHERE RIGID NON-METALLIC CONDUIT TRANSITIONS TO METALLIC CONDUIT, THE LOCATION OF THE FOLLOWING: ROADWAYS (PAVED OR IMPROVED), PARKING AREAS, SIDEWALKS, WALLS, STAIRS, MECHANICAL IN ORDER TO MAINTAIN THE ESTABLISHED FIRE RATING WITH METHODS AS APPROVED BY THE TRANSITION SHALL BE UNDERGROUND. WORK, CURBS, GUTTERS, ETC., CUT TO INSTALL WORK PROVIDED BY THE CONTRACTOR. PATCH AUTHORITY HAVING JURISDICTION. 1. JOINING PLATES, END CAPS, RETAINING CLIPS, ETC. WORK SHALL COMPLY WITH THE APPLICABLE SECTIONS OF THESE SPECIFICATIONS AND SHALL E. NO PVC CONDUIT SHALL BE RUN EXPOSED, OR ABOVE GRADE. 2. TRIMS FOR RECESSED FIXTURES. MATCH THE EXISTING FINISHES. III. IDENTIFICATION: 3. FIXTURE STEMS AND CANOPIES FINISHED TO MATCH FIXTURES. Al. WIRE AND CABLE 600 VOLT: 4. SPECIAL MOUNTING BRACKETS, TENONS, SLIP FILTERS, CONCRETE BASES, POLES, ANCHOR M. UPON COMPLETION OF WORK, THE ENTIRE WIRING SYSTEM SHALL BE TESTED, AND SHALL BE A. IDENTIFICATION NAMEPLATES SHALL BE LAMINATED PLASTIC, SECURED TO EQUIPMENT WITH TWO BOLTS, JUNCTION BOXES, AND STANCHIONS FOR ALL EXTERIOR LIGHTING FIXTURES. SHOWN TO BE IN PROPER WORKING CONDITION IN ACCORDANCE WITH INTENT OF SPECIFICATIONS SCREWS. A. CONDUCTORS SHALL HAVE CURRENT CARRYING CAPACITIES AS PER NEC AND WITH 600 VOLT PROVIDE ALL WEATHERPROOFING FOR ALL LIGHTING FIXTURES TO BE INSTALLED IN AND DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE ALL SYSTEMS INSULATION, #12 AVERAGE MINIMUM FOR 20 AMP CIRCUITS AND #14 FOR 15 AMP CIRCUITS EXTERIOR LOCATIONS. READY FOR OPERATION AND TO HAVE AN ELECTRICIAN AVAILABLE TO OPERATE SAME IN B. EACH PANELBOARD AND SWITCHBOARD SHALL BE EQUIPPED WITH A PERMANENT PLASTIC EXCEPT FOR CONTROLS, AND FIXTURE WIRE. CONDUCTORS SHALL BE COPPER. ACCORDANCE WITH AND UNDER THE SUPERVISION OF THE INSPECTION REPRESENTATIVE OF THE NAMEPLATE WITH 1/2" MINIMUM LETTERS, SECURELY FASTENED TO THE DEVICE. D. STRUCTURAL SUPPORT OF ALL FIXTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ENGINEER. THE CONTRACTOR SHALL BE AVAILABLE TO ASSIST IN REMOVAL OF PANEL FRONTS, B. #12 AND #10 SHALL BE SOLID, TYPE THW/THWN INSULATION. ETC., TO PERMIT INSPECTION AS REQUIRED. C. EACH INDIVIDUALLY MOUNTED CIRCUIT BREAKER, SWITCH, TRANSFER SWITCH, MOTOR STARTER, E. THE SYSTEM GROUNDING CONDUCTOR SHALL BE SECURED TO EACH FIXTURE BODY BY MEANS LIGHTING CONTACTOR, TRANSFORMER AND/OR ANY OTHER CONTROL OR PROTECTIVE DEVICE C. #8 AND LARGER, AND ANY SIZE TO MOTORS SHALL BE STRANDED TYPE THW. OF A BONDING SCREW. N. IN ACCORDANCE WITH DIVISION 1 AND THE CONDITIONS OF THE CONTRACT, THE CONTRACTOR INCLUDING EQUIPMENT DISCONNECT SWITCHES SHALL BE EQUIPPED WITH A PERMANENT PLASTIC SHALL PROVIDE AND KEEP UP TO DATE A COMPLETE RECORD SET OF CONSTRUCTION "AS-BUILTS". NAMEPLATE WITH 1/ 2" MINIMUM LETTERS. D. SHALL BE MADE WITH T & B STA-KON WIRE JOINTS, PT SERIES, COMPLETE WITH INSULATING F. OWNER/DEVELOPER WILL HAVE RIGHT TO RELOCATE LIGHTING FIXTURES OR LIGHTING SWITCHES BLUELINE PRINTS WHICH SHALL BE CORRECTED DAILY, AND SHALL SHOW EVERY CHANGE FROM WITHIN 72" OF LOCATION SHOWN ON FIRST WALK-THROUGH AT NO ADDITIONAL EXPENSE. .THE ORIGINAL CONTRACT DRAWINGS, INCLUDING ADDENDA AND CHANGE ORDERS IN CAPS AND INSTALLED WITH WT161 TOOL OR WT2000 TOOL, IDEAL SUPER -NUTS (NOT WIRE D. PANELBOARDS SHALL HAVE TYPEWRITTEN DIRECTORIES. ALL CIRCUITS TO BE IDENTIFIED BY NUTS), IDEAL WING NUTS, OR BUCHANAN ELEC. PRODUCTS B CAP OR SERIES 2000 PRES COORDINATE THE WALK-THROUGH PRIOR TO THE INSTALLATION OF THE WIRING. ACCORDANCE WITH GENERAL REQUIREMENTS AND SPECIAL CONDITIONS. THIS SET OF DEVICES SERVED AND ROOM NUMBERS (I.E., LIGHTING ROOM 216). HANDWRITTEN DIRECTORIES WILL SURE CONNECTORS COMPLETE WITH NYLON SNAP-ON INSULATORS AND INSTALLED WITH C24 PRINTS SHALL BE KEPT ON THE JOB SITE, AND SHALL BE USED, ONLY AS A RECORD SET. THIS NOT BE ALLOWED. PRESSURE TOOL. SHALL NOT BE CONSTRUED AS AUTHORIZATION FOR THE CONTRACTORS TO MAKE CHANGES IN THE LAYOUT WITHOUT DEFINITE INSTRUCTION IN EACH CASE. E. EACH JUNCTION BOX CABINET OR WIREWAY LARGER THAN 6„ X 6" SHALL BE EQUIPPED WITH A E. ALL JOINTS AND SPLICES IN WIRE SHALL BE AMADE WITH PPROVED EQUAL R�OEp CONDUCTOR S INSULATION. ORS, 11, ELECTRICAL SCOPE: PLASTIC NAMEPLATE WITH 1/2" MINIMUM LETTERS INDICATING THE SYSTEM ENCLOSED. AND COVERED SO THAT INSULATION IS OWNER AJoseph, Lawrence Co SPLICES SHALL NOT BE PERMITTED IN CONTROL, SECURITY, FIRE ALARM, TELEVISION OR A. FURNISHING AND. INSTALLATION OF POWER SYSTEMS, AND AUXILIARY SYSTEMS AS SHOWN F. ALL SYSTEMS JUNCTION BOXES AND CONDUIT SHALL BE COLOR CODED INSIDE AND OUTSIDE OF COMMUNICATIONS SYSTEMS, OR WHERE OTHERWISE NOTED. SPLICING OF WIRE OR CABLES WILL Consulting Engineers OR HEREIN SPECIFIED. THE BOX PRIOR TO THE INSTALLATION OF CONDUCTORS PER THE FOLLOWING: NOT BE ALLOWED BELOW GRADE, INCLUDING IN BOXES BELOW GRADE. 1180 HARWOOD AVE„ SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 B. CONNECTION OF ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTION, MENTIONED IN THIS 1. CCN SYSTEM: GREEN F. BOTH CONDUCTORS AND CONDUITS SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. TWW.JLCENG. O 2. TELEPHONE DATA SYSTEM: BLUE 66 WWW.JLCENG.COM DIVISION OR SHOWN ON DRAWINGS, WHETHER FURNISHED BY DIVISION 16 OR UNDER CA NO. 28730 OTHER DIVISIONS, OR FURNISHED BY OWNER. 3. FIRE ALARM SYSTEM: RED G. IN INSTALLING THE MAIN ELECTRICAL SERVICE, ADDITIONAL SLACK CONDUCTORS SHALL BE _.___.• PROVIDED AND TERMINATED AS REQUIRED BY ELECTRIC UTILITY FOR CONNECTION TO THEIR \����11111>rrJLC 17.0258.00 C. FURNISHING AND INSTALLATION OF OUTLET BOXES, CONDUIT RACEWAYS, FOR A TELEPHONE AND G. ENTIRE BOX INSIDE AND OUT, INCLUDING COVER, SHALL BE PAINTED PRIOR TO INSTALLING EQUIPMENT. FIELD COORDINATE WITH UTILITY PRIOR TO INSTALLING CONDUCTORS. <�`� L 5UQp'// DATA RACEWAY DISTRIBUTION SYSTEM. (TELEPHONE AND DATA HARDWARE, AS WELL AS WIRING AND CONDUCTORS. H. IN INSTALLING PARALLEL CONDUCTORS IT IS MANDATORY THAT ALL CONDUCTORS MAKING UP THE �\,P OceNSF SOFTWARE IS NOT INCLUDED.) IV. WIRING DEVICES: FEEDER BE EXACTLY THE SAME LENGTH, THE SAME SIZE AND THE SAME TYPE OF CONDUCTOR No.69060 WITH THE SAME INSULATION. FURTHER, EACH GROUP OF CONDUCTORS MAKING UP A PHASE OR - * �k --Blake L Suddeth D. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR CONTACTING THE OFFICES OF ALL LOCAL A. SWITCHES AND RECEPTACLES IN LOBBIES, CORRIDORS OR COMMERCIAL SPACES, UNFINISHED AND NEUTRAL MUST BE BONDED AT BOTH ENDS IN AN APPROVED MANNER. = -o l ' X AND/OR STATE AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT IN ORDER TO SCHEDULE ALL MECHANICAL SPACES SMALL BE 20 AMP COMMERCIAL GRADE 125 VAC. GRAY IN COLOR WITH ,� STATE OF w2018.01.31 REQUIRED INSPECTIONS AND OBTAIN ALL NECESSARY PERMITS, ETC. THE CONTRACTOR SHALL NOTIFY STAINLESS STEEL COVERPLATES. I. CONDUCTOR SIZES INDICATED ON CIRCUIT HOMERUNS OR IN PANELBOARD SCHEDULES SHALL BE ��` ` •.;"<ORII>P •'••�15:09:55-05'00' THE ARCHITECT/ENGINEER OF ALL SCHEDULED INSPECTIONS AT LEAST TWO WEEKS IN ADVANCE OF INSTALLED OVER THE ENTIRE LENGTH OF THE CIRCUIT UNLESS NOTED OTHERWISE ON THE '� s �G.� THE SCHEDULED DATE. B. WEATHERPROOF RECEPTACLES SHALL BE GFCI TYPES WITH GASKETED STAINLESS STEEL KEY DRAWINGS. ��� S��NA� ��` LOCKABLE FLIP COVER TYPE COVERPLATES. SURGE SUPPRESSION TYPE OUTLETS IN MDFS AND IDFS /rrrrrllll`1�\\ Blake Lawrence Suddeth CONTRACTOR SHALL REPLACE ANY DEFECTIVE MATERIALS, EQUIPMENT, OR WORKMANSHIP Th., item has Uaene. Printed copla6naduedocume by Bl.. L. Suddeth, PE on the Date andtor Time Stamp eh - E. THE 0 SHALL BE HUBBELL #83625 (BLUE) OR EQUAL. J. CONDUCTORS SHALL BE CONTINUOUS AND UNSPLICED WHERE INSTALLED IN CONDUIT: SPLICES netcond, tedMgmadrand...l dant eaignot- ..taba P.E. #: 69060 WITHOUT COST TO THE OWNER WITHIN THE STIPULATED GUARANTEED PERIOD. SHALL OCCUR ONLY WITHIN WIRING TROUGHS, WIREWAYS, JUNCTION BOXES, OUTLET BOXES, OR `°°edeeda�nedanany.1.&.*copa., t°am°"ha Yadfiad °n any electronic °aPiea F. IT SHALL BE THE RESPONSIBILITY OF THE DIVISION 16 CONTRACTOR TO HAVE ALL SYSTEMS C. RECEPTACLES PROVIDED FOR ATTACHMENT OF CORD AND PLUG EQUIPMENT SHALL BE HEAVY EQUIPMENT ENCLOSURES WHERE SUFFICIENT ADDITIONAL ROOM IS PROVIDED FOR ALL SPLICES. READY FOR OPERATION AND TO HAVE AN ELECTRICIAN AVAILABLE FOR ALL INSPECTIONS. THE DUTY, SPECIFICATION GRADE, NON -INTERCHANGEABLE, FLUSH MOUNTED TYPES OF THE PROPER NEMA CONFIGURATION TO SERVE THE EQUIPMENT. NEMA CONFIGURATIONS SHALL BE VERIFIED PRIOR T4 K. EACH BRANCH CIRCUIT AND FEEDER CONDUCTOR SHALL BE COLOR CODED. FOR CONDUCTOR _ CONTRACTOR SHALL PROVIDE PERSONNEL TO ASSIST IN REMOVAL OF PANEL FRONTS, ETC. TO PERMIT INSTALLATION OF CIRCUIT CONDUCTORS. CONTRACTOR TO PROVIDE ALL CONNECTION, WIRING, PIGTAILS SIZES THRU NO. 6 AWG, THE INSULATION SHALL BE OF THE COLOR AS INDICATED BELOW. COLOR SPECIFICATIONS ELECTRICAL INSPECTION AS REQUIRED. FOR DISHWASHERS, COOKING RANGES, OVENS AND GARBAGE DISPOSALS. CODE SHALL BE STRICTLY ADHERED TO. FOR CONDUCTOR SIZES NO. 4 AWG AND LARGER, COLOR CODED PHASE TAPE MAY BE APPLIED COMPLETELY AROUND THE CONDUCTOR INSULATION G. SUBMIT TO THE ARCHITECT/ENGINEER PROMPTLY AFTER AWARD OF CONTRACT AND PRIOR TO D. ALL DEVICES SHALL HAVE PROPER PLATES, CARPET FLANGES, TRIMS, RINGS, ESCUTCHEONS, WITHIN 8 OF EACH END OF THE CONDUCTOR AND IN EACH PULL OR JUNCTION BOX OR WHENEVER PURCHASING, SIX COPIES OF MANUFACTURER'S SHOP DRAWINGS IN ACCORDANCE WITH ETC., AS MANUFACTURED BY SAME MANUFACTURER AS DEVICES. ANY TELEPHONE OR OTHER OUTLET CONDUCTORS ARE PHYSICALLY EXPOSED TO VIEW. GROUNDING CONDUCTORS AND GROUNDED DIVISION 1, SECTION 01300 SUBMITTALS FOR THE FOLLOWING ITEMS. ALL SHOP DRAWINGS OF A WHICH IS NOT EQUIPPED WITH A PLATE FURNISHED BY OTHERS SHALL HAVE ONE PROVIDED BY THIS CONDUCTORS SHALL HAVE INSULATION COLOR AS INDICATED FOR SIZES THROUGH #6 AWG. SULLIVAN'S PUBLIC HOUSE SPECIFIC ITEM OR SYSTEM SHALL BE MADE IN ONE SUBMITTAL AND WITHIN TEN DAYS AFTER AWARD CONTRACTOR. DEVICE PLATES SHALL BE COLOR AND TYPE AS SHOWN BELOW. 120/208 V, 3PHASE,4WOF 116 E FIRST STREET 1. FINISHED SPACES DECORA LINE: PHASE A, COLOR: BLACK 1. PANELBOARDS 4. DISCONNECT SWITCHES a. IVORY DEVICES PHASE B, COLOR: RED SANFOnJn.Jt_lT� , FL 32771 2. SUPPORTS 5. CONDUIT b. IVORY NYLON PLATES PHASE C, COLOR: BLUE 3. WIRING DEVICES 6. WIRE 2. UNFINISHED OR INDUSTRIAL OR COMMERCIAL TYPE SPACES: NEUTRAL, COLOR: WHITE 100% CDs o. GRAY DEVICES GROUND, COLOR: GREEN H. COMPLETED WIRING SYSTEMS SHALL BE FREE FROM SHORT CIRCUITS AND AFTER COMPLETION, b. STAINLESS STEEL OR STAMPED GALVANIZED STEEL ON SURFACE MOUNTED BOXES MILZARCH LLC 01/31/18 PERFORM TESTS FOR INSULATION RESISTANCE IN ACCORDANCE WITH THE REQUIREMENTS OF THE c. STAINLESS STEEL PLATES ON FLUSH MOUNTED BOXES VIII. GROUNDING: NATIONAL ELECTRICAL CODE. ALL WIRING SYSTEMS SHALL BE COMPLETELY AND TOTALLY "SAFED" DURING CONSTRUCTION. ONLY QUALIFIED PERSONNEL SHALL HANDLE ELECTRICAL SYSTEMS. A. THIS SECTION DEALS WITH THE GROUNDING OF SERVICE EQUIPMENT, TRANSFORMERS, NON- JERRY WALKER MILLS, SR. CURRENT CARRYING CONDUCTIVE SURFACES OF EQUIPMENT, METAL BUILDING, STRUCTURES AND ,t SHEET L BEFORE ROUGH -IN OF CIRCUITRY OR CONNECTING TO EQUIPMENT, FURNISHED UNDER THIS OTHER EQUIPMENT. 407.921.8795 MILZARCH@GMAIL.COM J rl DIVISION, ANY OTHER DIVISION, OR BY THE OWNER, THE CONTRACTOR SHALL VERIFY THE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF THE EQUIPMENT BEING FURNISHED AND FOR THAT SPECIFIED AND SHOWN ON THE DRAWINGS AND PROVIDE FOR PROPER ROUGH -IN AND CONNECTION. AROOO8314 E6.1 pAM 6/0011 SEAL 701 WEST Third Street, Sanford, Me 32771 .LEGEND OPRAN SPECIFICATIONS GENERAL NOTES FOOD SERVICE NOTE D. INSULATION THICKNESS 1-1/2". - PART 2 - PRODUCTS 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY FITTINGS AS REQUIRED BY ALL APPLICABLE 1. ALL SERVICE LINES FOR WATER AND GAS SIZED TO PROVIDE FULL FLOW VOLUME DIRECTION OF FLOW IN PIPE PART 1 GENERAL CODES AND GOVERNING AUTHORITIES. FOR ALL ITEMS SUPPLIED ON RESPECTIVE MAINS AND BRANCHES. IDENTIFY ALL 8. 1.1 SECTION INCLUDES 2.1 PIPE HANGERS AND SUPPORTS 6. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES. LINES WITH PERMANENT LABELS FOR THE SERVICE THEY PROVIDE: PITCH PIPE DOWN IN DIRECTION OF ARROW A. GENERAL PROVISIONS SPECIFICALLY APPLICABLE TO DIVISION 15 A. MANUFACTURERS: 2. CONTRACTOR SHALL VERIFY AND CORRECT AS REQUIRED TO MEET ALL CODES AND REGULATIONS ANY POSSIBLE 5. ALL PIPING ROUTED THROUGH OR NEAR EQUIPMENT OR COUNTERS SHALL NOT 2.3 PIPING: SANITARY SEWER PIPING ---;��I- CHECK VALVE, HORIZONTAL SWING SECTIONS IN ADDITION TO DIVISION 1 - GENERAL A.1 B -LINE DISCREPANCIES BETWEEN TYPE AND SIZE OF CONNECTION SPECIFIED IN PLUMBING FIXTURE SCHEDULE AND 2. FUEL GAS SERVICES SHALL BE SIZED TO SUPPLY THE REQUIRED BTUH INDICATED -v-^v PIPE UP REQUIREMENTS. A.2 OTHER ACCEPTABLE MANUFACTURERS OFFERING FIXTURES ACTUALLY INSTALLED ON THE SITE. AT THE EQUIPMENT AT LOW PRESSURE OF APPROXIMATELY 7"-11" WATER . PVC: ASTM D2665 SCHEDULE 40 PVC SOLID WALL PIPING. 9. EQUIVALENT PRODUCTS.COLUMN. PROVIDE PRESSURE REGULATORS AS REQUIRED. ^ PIPE DOWN 1.2 SCOPE A.2.1 MICHIGAN HANGER 3. ALL DRAINAGE PIPING 21"AND LARGER SHALL HAVE A MINIMUM " PER FOOT SLOPE. ALL DRAINAGE PIPING 2" AND AND/OR SMOKE DAMPERS, AND OTHER BASIC ITEMS REQUIRED BY A.1 FITTINGS: ASTM D2665 SCHEDULE 40 PVC DWV FITTINGS. A. THE WORK SHALL INCLUDE THE PROVISIONS OF SYSTEMS, A.2.2 PHD SMALLER SHALL HAVE A MINIMUM I" PER FOOT SLOPE, UNLESS OTHERWISE NOTED. 3. ALL HOT AND COLD WATER SERVICE LINES, EXCEPT SHORT BRANCHES EXTENDED EJ EQUIPMENT AND MATERIALS SPECIFIED IN THIS DIVISION AND AS AND CONNECTED TO FIXTURES, SHALL BE INSULATED. ALL EXPOSED INSULATED A.2 JOINTS: ASTM D2564 SOLVENT CEMENT. JOINTS SHALL -�-- EXPANSION JOINT CALLED FOR ON THE DRAWINGS. WORK SHALL ALSO INCLUDE 2.2 PIPING INSULATION: 4. VENT PIPING SHOWN ON FLOOR PLANS IS ONLY INDICATIVE EXCEPT FOR VTR LOCATIONS.. LINES SHALL BE COVERED WITH PROTECTIVE COVERING TO SUIT THE APPLICATION. E TIOETHODS AND LABOR FOR THE A MANUFACTURERS M FOR THE PROPER INSTALLATION OF THE WORK. BE INSTALLED IN ACCORDANCE WITH ASTM D2855. EM- FLEXIBLE PIPE CONNECTOR SUPERVISION, , FABRICATION, S TART -UP AND TESTS FOR A COMPLETE OPERATIONAL A.1 OWENS CORNING FITTINGS SHALL BE OF SAME SIZE OF LINE ON WHICH THEY ARE LOCATED UNLESS OTHERWISE 5. VALVES AND TT , 4. ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT, BELOW D. INSULATION THICKNESS 1-1/2". PLUMBING INSTALLATION. A.2 JOHNS MANVILLE INDICATED ON DRAWINGS. EQUIPMENT, SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATION ABOVE FLOOR, -I®I-- BALL VALVE A.3 KNAUF TO PROVIDE CLEARANCE FOR CLEARING. NO LINES SHALL LAY ON FLOOR. 8. B. DRAWINGS FOR THE WORK ARE DIAGRAMMATIC IN NATURE AND ARE B. ASTM C547, RIGID MOLDED NON-COMBUSTIBLE FIBERGLASS 6. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES. ALL EXPOSED PIPING AND FITTINGS SHALL BE CHROME PLATED OR STAINLESS -•- INTENDED TO CONVEY THE SCOPE OF THE INSTALLATION AND TO INSULATION. 'K' VALUE .024 ® 75 DEGREES F. 5. ALL PIPING ROUTED THROUGH OR NEAR EQUIPMENT OR COUNTERS SHALL NOT 2.3 PIPING: SANITARY SEWER PIPING ---;��I- CHECK VALVE, HORIZONTAL SWING INDICATE THE GENERAL ARRANGEMENT AND LOCATIONS OF THE C. VAPOR BARRIER JACKET, KRAFT PAPER WITH GLASS FIBER YARN AND 7. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS PRIOR TO LAYING AND CONNECTING ALL SANITARY INTERFERE WITH THE INTENDED USE OF, OR SERVICING OF, EQUIPMENT OR WORK. - BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC BONDED TO ALUMINUM FILM. CLOSURE SYSTEM SHALL BE UL 181. AND WASTE PIPING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. COUNTERS. . PVC: ASTM D2665 SCHEDULE 40 PVC SOLID WALL PIPING. >0-- GATE VALVE ITEM'S SUCH AS PIPE FITTINGS, ACCESS PANELS, AND SLEEVES MAY D. INSULATION THICKNESS 1-1/2". NOT BE SHOWN. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR 8. AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER ARRESTORS AS SPECIFIED. 6. ALL EXPOSED PIPING AND FITTINGS SHALL BE CHROME PLATED OR STAINLESS -1�I- BUTTERFLY VALVE SELECTING THE EQUIPMENT TO FIT THE SPACE PROVIDED. THE 2.3 PIPING: SANITARY SEWER PIPING STEEL. TAIL PIECES FOR SINKS SHALL BE 17 GAUGE CHROME PLATED FLARED LOCATION AND SIZES FOR PIPE FITTINGS, SLEEVES, INSERTS, FIREA . PVC: ASTM D2665 SCHEDULE 40 PVC SOLID WALL PIPING. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL BRASS TUBING FOR CONNECTION TO 1-1/2" I.P.S. MALE THREAD FITTING. "P" per-- GLOBE VALVE AND/OR SMOKE DAMPERS, AND OTHER BASIC ITEMS REQUIRED BY A.1 FITTINGS: ASTM D2665 SCHEDULE 40 PVC DWV FITTINGS. PIPING AND PENETRATIONS. TRAPS SHALL BE CHROME PLATED BRASS, UNIFORM CODE PATTERN: CODE AND OTHER SECTIONS SHALL BE COORDINATED AND INCLUDED A.2 JOINTS: ASTM D2564 SOLVENT CEMENT. JOINTS SHALL BALANCING VALVE FOR THE PROPER INSTALLATION OF THE WORK. BE INSTALLED IN ACCORDANCE WITH ASTM D2855. 10. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO PLANS AS POSSIBLE WITH NO CHANGES IN 7. STOPS SHALL BE FURNISHED AND INSTALLED ON ALL HOT AND COLD WATER LINES SIZING. AT EQUIPMENT. PROVIDE ALL REQUIRED SHUT-OFF VALVES, CHROME FINISH. BC --I�I- BALANCING COCK C. EQUIPMENT SPECIFICATIONS MAY NOT DEAL INDIVIDUALLY WITH 2.4 PIPING: WATER PIPING MINUTE ITEMS REQUIRED SUCH AS COMPONENTS, PARTS, CONTROLS A. COPPER PIPING: ASTM B88 TYPE 'L' HARD DRAWN. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY SUPPORTING DEVICES FOR ALL FIXTURES 8. KITCHEN EQUIPMENT DIVISION SHALLPROVIDE ALL FOOD SERVICE EQUIPMENT --�}- STRAINER Y -TYPE AND BLOWOFF VALVE AND DEVICES WHICH MAY BE REQUIRED TO PRODUCE THE A.1 FITTINGS: ASME 16.18 CAST BRONZE OR ASME B16.22 INCLUDED IN CONTRACT OR HEREIN SPECIFIED OR OTHERWISE. FAUCETS. PLUMBING CONTRACTOR SHALL INSTALL AND CONNECT. 'S. EQUIPMENT PERFORMANCE SPECIFIED OR AS REQUIRED TO MEET THE WROUGHT .COPPER OR BRONZE. RV PRESSURE RELIEF VALVE. (WATER) EQUIPMENT WARRANTIES. WHERE SUCH ITEMS ARE REQUIRED, THEY SHALL BE INCLUDED BY THE INSTALLER OF THE EQUIPMENT, A.2 JOINTS: ASTM B32 SOLDER, ASTM 95-5 TA MINIMUM, INSTALLED IN 12. CHANGES IN THE DIRECTION OF SANITARY PIPING SHALL NOT BE MADE WITH FITTINGS WHICH WILL CAUSE EXCESSIVE REDUCTION IN THE VELOCITY OF FLOW OR CREATE ANY OTHER ADVERSE EFFECT UNLESS PHYSICALLY 9. EQUIPMENT SINKS ARE PROVIDED WITH 1-1/2" WASTE CONNECTIONS. FLUX ASTM B813. JOINTS SHALL BE WHETHER OR NOT SPECIFICALLY INDICATED IN THE CONTRACT ACCORDANCE WITH ASTM 8828. IMPOSSIBLE IE: USE OF SANITARY TEE IN A HORIZONTAL CON- NECTION, USE OF A DOUBLE SANITARY TEE IN A 10. ALL WASTES, DIRECT OR INDIRECT, SHALL BE FURNISHED AND INSTALLED BY THE PRV PRESSURE REDUCING VALVE DOCUMENTS WITH NO ADDITIONAL COST INCURRED. A.3 SUBSTITUTIONS: CPVC IS AN ACCEPTABLE ALTERNATIVE VERTICAL STACK, IN GENERAL, USE OF SHORT -RADIUS FITTINGS FOR BRANCH TO HOUSE DRAIN OR STACK PLUMBING CONTRACTOR EXCEPT AS NOTED ON UTILITY PLANS. MINIMUM SIZE TO COPPER ONLY IF APPROVED BY BUILDING OWNER. CONNECTION). INDIRECT WASTES SHALL BE 1", REGARDLESS OF SIZE OF CONNECTION AT MAV D. WHERE NOTED ON THE DRAWINGS OR INDICATED IN OTHER SECTIONS EQUIPMENT. REDUCING FITTINGS MANUAL AIR VENT OF THE SPECIFICATION, THE CONTRACTOR FOR THIS DIVISION SHALL 2.5 PIPING: GAS PIPING 13. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL SANITATION FOUNDATION. INSTALL PLUMBING EQUIPMENT FURNISHED BY OTHERS, AND SHALL A. STEEL PIPE: ASTM A 53/A 53M; TYPE E OR S; GRADE B; BLACK. WALL 11. ADEQUATE CLEAN-OUT PROVISION SHALL BE MADE FOR ALL WASTE LINES BY MAKE ALL FINAL CONNECTIONS. CONTRACTOR SHALL INSTALL THICKNESS OF WROUGHT -STEEL PIPE SHALL COMPLY WITH ASME B36.10M. 14. DO NOT PENETRATE FOUNDATIONS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR TO DROP FOUNDATIONS MEANS OF PLUGGED "T" FITTING EXTENDED TO ACCESSIBLE POSITION. ___0tF_ SOLENOID VALVE EQUIPMENT AND SYSTEMS IN STRICT ACCORDANCE WITH A.1 MALLEABLE -IRON THREADED FITTINGS: ASME B16.3, AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING PENETRATING A BEARING MANIUFACTURERS RECOMMENDATIONS. CLASS 150, STANDARD PATTERN, WITH THREADED ENDS WALL OR FOOTING MUST BE SLEEVED AND LOCATION APPROVED BY STRUCTURAL ENGINEER. 12. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL DRAIN LINES FROM COOLERS VALVE OS & Y ACCORDING TO ASME 81.20.1. AND FREEZERS TO DRAIN LOCATIONS WITH MINIMAL PITCH AND "P" TRAP E. COORDINATE WITH ALL TRADES IN SUBMITTAL OF SHOP DRAWINGS. A.2 STEEL THREADED FITTINGS: ASME 816.11, FORGED STEEL 15. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES. PIPING EXPOSED SHALL BE SLOPED IN END OVER FLOOR RECEPTOR DRAIN LINES SHALL BE 1 MINIMUM. EACH UNIT S SHA E CAPPED LINE TIGHT SPACE CONDITIONS SHALL BE DETAILED TO THE SATISFACTION WITH THREADED ENDS ACCORDING TO ASME B1.20.1. AND PAINTED TO MATCH ARCHITECTURAL FINISHES. PIPING IN MECHANICAL ROOMS MAY BE EXPOSED. SHALL HAVE A SEPARATE DRAIN LINE. OF ALL TRADES, SUBJECT TO THE REVIEW AND FINAL ACCEPTANCE A.3 STEEL WELDING FITTINGS: ASME 816.9, WROUGHT STEEL OR - SAN SANITARY SEWER (ABOVE GRADE) OF THE ARCHITECT/ENGINEER. IN THE EVENT THAT THE CONTRACTOR ASME 816.11, FORGED STEEL A.4 AMEUNIONS: ASME FORGEB16.3SCLASSTEEL 150, MALLEABLE IRON WITH 16. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON- ACCESSIBLE CEILINGS. REFER TO 13. GAS AND WATER SERVICES FOR PORTABLE AND COUNTER TOP APPLIANCES SHALL INSTALLS HIS WORK BEFORE COORDINATING WITH OTHER TRADES OR , BRASS -TO -IRON SEAT, GROUND JOINT, AND THREADED ENDS ARCHITECTURAL DRAWINGS FOR CEILING TYPES. BE CONNECTED T4 EQUIPMENT WITH STAINLESS STEEL FLEXIBLE HOSES AND - -SAN - - SANITARY SEWER (BELOW GRADE) SO AS TO CAUSE ANY INTERFERENCE WITH THE WORK OF THE ACCORDING TO ASME 81.20.1. QUICK DISCONNECT FITTINGS. GAS FITTINGS AND HOSES SHALL BE A.G.A. OTHER TRADES THIS CONTRACTOR SHALL MAKE ALL REQUIRED A.5 CAST-IRON FLANGES AND FLANGED FITTINGS: ASME B16.1, 17. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF PLUMBING FIXTURE MOUNTING HEIGHTS, AND DIMENSIONS. APPROVED FOR COMMERCIAL KITCHEN EQUIPMENT. GAS AND WATER HOSES SHALL - DOMESTIC COLD WATER (CWS) CHANGES TO CORRECT THE CONDITION AT NO ADDITIONAL COST TO CLASS 125. BE COVERED WITH A THICK FIRE RESISTANT PLASTIC OR POLY COATING. THE PROJECT. A.6 JOINT COMPOUND AND TAPE: SUITABLE FOR NATURAL GAS. 18. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH NEW SEWER LINES ARE TO BE CONNECTED BP-- BOOSTED PRESSURE DOMESTIC COLD WATER A.7 STEEL FLANGES AND FLANGED FITTINGS: ASME B16.5. BEFORE INSTALLATION OF NEW SEWER LINE. 14. PLUMBING CONTRACTOR SHALL COORDINATE WITH KITCHEN CONSULTANT DRAWINGS F. CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTION SIZES A.8 GASKET MATERIAL: THICKNESS, MATERIAL, AND TYPE SUITABLE FOR ROUGH IN LOCATIONS, SIZES AND HOOK-UP REQUIREMENTS FOR ALL -- DOMESTIC HOT WATER (HWS). PRIOR TO INSTALLATION OF ANY SYSTEMS. THIS CONTRACTOR SHALL FOR NATURAL GAS. 19. ALL VENTS THROUGH ROOF SHALL BE MINIMUM OF 10'-0" FROM ANY AIR INTAKES. KITCHEN EQUIPMENT. ROUGH IN EQUIPMENT PER MANUFACTURERS ADJUST PIPING SYSTEM SIZES AS REQUIRED TO MATCH EQUIPMENT RECOMMENDATIONS. - - - - DOMESTIC HOT WATER RETURN (HWR) CONNECTIONS. UTILIZE REDUCERS WHERE EQUIPMENT CONNECTIONS PART 3 - INSTALLATION 20. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS: ARE SMALLER THAN PIPE SIZES INDICATED ON PLANS, NO PIPING SHALL BE DECREASED IN SIZE (IN THE DIRECTION OF FLOW).21. 3.1 INSTALL IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS (INCLUDING PIPE ROUTING AND EQUIPMENT LOCATIONS) TO 15. PROVIDE OWNER WITH 1/4" SCALE COORDINATED AS -BUILT DRAWINGS FOR ALL WORK TO BE PERFORMED. lW DOMESTIC TEMPERED HOT WATER 1.3 EXAMINATION OF BIDDING DOCUMENTS: 3.2 PROVIDE NON -CONDUCTING DIELECTRIC CONNECTIONS WHEREVER ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL PRIOR TO THE INSTALLATION OR PURCHASING OF ANY PIPING --CD-- CONDENSATE DRAIN (BELOW GRADE) A. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY JOINTING DISSIMILAR METALS. AND/OR EQUIPMENT. CD CONDENSATE DRAIN (ABOVE GRADE) AND, NOT LATER THAN TEN (10) DAYS PRIOR TO THE DATE FOR 3.3 ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRADIENT. 22. PROVIDE 1/2" C.W. SUPPLY WITH ANGLE STOP AND FLEXIBLE SUPPLY TO RE- FRIGERATORS WITH ICE MAKERS AT RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO THE ENGINEER HEIGHT REQUIRED BY MANUFACTURE OF EQUIPMENT INSTALLED - - ST - - STORM SEWER (BELOW GRADE) FOR INTERPRETATION OR CORRECTION OF ANY AMBIGUITY, 3.4 INSTALL PIPING TO CONSERVE BUILDING SPACE AND NOT INTERFERE WITH INCONSISTENCY OR ERROR THEREIN. ANY INTERPRETATION OR USE OF SPACE. 23. PROVIDE 1/2" H.W. SUPPLY WITH ANGLE STOP AND FLEXIBLE SUPPLY TO DISH WASHER MACHINE, AT HEIGHT RENOVATION ST STORM SEWER (ABOVE GRADE) CORRECTION WILL BE ISSUED AS AN ADDENDUM BY THE ENGINEER. REQUIRED BY MANUFACTURER OF EQUIPMENT INSTALLED. RENOVATION NOTE 5 EO STORM EMERGENCY OVERFLOW PIPING ONLY A WRITTEN INTERPRETATION OR CORRECTION TO BID 3.5 GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS. DOCUMENTS BY ADDENDUM SHALL BE BINDING. NO BIDDER SHALL 24. ALL WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE PLACED ON THE INTERIOR SIDE OF THE WALL, SO RELY UPON ANY INTERPRETATION OR CORRECTION GIVEN BY ANY - - GR - - GREASE .SEWER (BELOW GRADE) OTHER METHOD. 3.6 INSTALL PIPING TO ALLOW .FOR EXPANSION AND CONTRACTION WITHOUT THAT WALL INSULATION CAN BE PLACED ON THE EXTERIOR SIDE OF THE PIPING. GR GREASE SEWER (ABOVE GRADE) STRESSING PIPE, JOINTS, OR CONNECTED EQUIPMENT. 25. WHERE EXISTING PIPING IS DESIGNATED TO BE REMOVED AND CAPPED, ALL PIPING SERVING THE DESIGNATED 1.4 SUBSTITUTIONS: 1. WHERE EXISTING PIPING IS DESIGNATED TO BE REMOVED AND CAPPED, ALL PIPING - -SCW - - OLD WATER A. EXCEPT AS PROVIDED BELOW, EACH BIDDER REPRESENTS THAT HIS 3.7 PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND ACCESS TO FIXTURE SHALL BE REMOVED FROM WITHIN WALLS TO THE POINT DESIGNATED ON THE DRAWINGS. PIPING SHALL SERVING THE DESIGNATED FIXTURE SHALL BE REMOVED FROM WITHIN WALLS TO THE SOFT C VALVES AND FITTINGS. BE CAPPED BY APPROVED CAPPING METHODS UTILIZING PIPE CAPS INTENDED FOR SUCH USE. CAPS SHALL BE BID IS BASED UPON THE MATERIALS AND EQUIPMENT DESCRIBED IN AIRTIGHT AND WATERTIGHT. POINT DESIGNATED ON THE DRAWINGS.. PIPING SHALL BE CAPPED BY APPROVED ---------- VENT THE BIDDING DOCUMENTS. 3.8 PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT EXPOSED. CAPPING METHODS UTILIZING PIPE .CAPS INTENDED FOR SUCH USE. CAPS SHALL - - G - - GAS LINE (BELOW GRADE) B. NO SUBSTITUTIONS FOR OTHER MATERIALS AND EQUIPMENT WILL BE COORDINATE SIZE AND LOCATION OF ACCESS DOORS WITH APPROPRIATE 26. WHERE EXISTING SURFACES ARE DISRUPTED DUE TO THE REMOVAL OF EXISTING EQUIPMENT OR PIPING, THIS BE AIRTIGHT AND WATERTIGHT. G GAS LINE(GRADE) CONSIDERED UNLESS WRITTEN REQUEST HAS BEEN SUBMITTED TO ARCHITECTURAL SECTION. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF DISRUPTED SURFACES TO MATCH EXISTING ADJACENT 2. WHERE EXISTING SURFACES ARE DISRUPTED DUE TO THE REMOVAL OF EXISTING ( THE ENGINEER FOR APPROVAL AT LEAST TEN (10) DAYS PRIOR TO SURFACES. . RECEIPT OF BIDS, EACH SUCH REQUEST SHALL 3.9 ESTABLISH ELEVATIONS OF BURIED PIPING OUTSIDE THE BUILDING TO EQUIPMENT OR PIPING, THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR THE DATE FOR IS POINT OF CONNECTION NEW INCLUDE A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE, ENSURE PROPER SLOPE AND COVER. 27. EXISTING CONDITIONS AS SHOWN ON THE DRAWINGS ARE TAKEN FROM ORIGINAL AND AS -BUILT DRAWINGS OF THE OF DISRUPTED SURFACES TO MATCH EXISTING ADJACENT SURFACES. TO EXISTING BUILDING AND IN PART ARE UNVERIFIED. FIELD CONDITIONS SHALL GOVERN. ALL EXISTING CONDITIONS MUST BE THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT IS TO 3.10 ESTABLISH ELEVATIONS OF EXISTING BURIED PIPING FOR CONNECTION TO VERIFIED PRIOR TO INITIATION OF WORK. 3. EXISTING CONDITIONS AS SHOWN ON THE DRAWINGS ARE TAKEN FROM ORIGINAL AND ® POINT OF REMOVAL FOR DEMOLITION BE SUBSTITUTED, DRAWINGS, CUTS, PERFORMANCE AND TEST DATA NEW WORK TO ENSURE PROPER SLOPE AND COVER. AS -BUILT DRAWINGS OF THE BUILDING AND IN PART ARE UNVERIFIED. FIELD OR INFORMATION NECESSARY FOR A COMPLETE EVALUATION. 28. ALL EXISTING PIPING, NOT REMAINING IN SERVICE AFTER NEW CONSTRUCTION, SHALL BE REMOVED. CONDITIONS SHALL GOVERN. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR AT DELTA T (TEMPERATURE DIFFERENCE) 3.11 WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL BUILDING TO INITIATION OF WORK. C. IF THE ENGINEER APPROVES ANY PROPOSED SUBSTITUTION, SUCH FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT OF ZINC RICH 29. PIPING WHICH IS TO REMAIN IN SERVICE SHALL NOT BE DISTURBED. EXISTING PIPING DAMAGED DURING APPROVAL WILL BE ISSUED AS AN ADDENDUM FORWARDED TO ALL PRIMER TO WELDING. CONSTRUCTION SHALL EM REPLACED WITH NEW PIPING OF THE SAME SIZE AND MATERIAL 4. ALL EXISTING PIPING, NOT REMAINING IN SERVICE AFTER NEW CONSTRUCTION, SHALL J ph L & C PARTICIPATING BIDDERS. BE REMOVED. ose ing Lawrence o A PHOTO DETAIL OR SECTION IDENTIFICATION TARGET 3.12 EXTEND CLEANOUTS TO FINISHED FLOOR OR WALL SURFACE. LUBRICATE 30. EXISTING BUILDING SEWERS THAT ARE USED WITH NEW BUILDING SANITARY SEWERS SHALL BE EXAMINED AND Consulting Engineer's A =DETAIL NUMBER. D. IF ANY BIDDER IS UNABLE TO PROCURE WRITTEN APPROVAL OF ANY F PLUMBING AUTHORITY HAVING JURISDICTION 5. PIPING WHICH IS TO REMAIN IN SERVICE SHALL NOT BE DISTURBED. EXISTING B B = SHEET NUMBER ON WHICH DETAIL IS LOCATED. SUBSTITUTION FROM THE ENGINEER PRIOR TO THE OPENING OF THREADED CLEANOUT PLUGS WITH MIXTURE OF GRAPHITE AND LINSEED TESTED TO CONFORM IN ALL RESPECTS TO ALL THE REQUIREMENTS 0 neo ONTE SPI AVE., SUITE 327 PIPING DAMAGED DURING CONSTRUCTION SHALL BE REPLACED WITH NEW PIPING OF A1.TA14oNTE scRiNcs, FLORIDA 3xna OIL. ENSURE CLEARANCE AT CLEANOUT FOR RODDING OF DRAINAGE AND APPLICABLE PLUMBING CODES. TEL: 321.97x.4466 BIDS, THEN HE SHALL BASE HIS BID ON ITEMS AND SYSTEMS AS SPECIFIED IN BID DOCUMENTS. SYSTEM. THE SAME SIZE AND MATERIAL. wCA N0.2$730 M HB 31. ALL EXISTING SANITARY, DOMESTIC WATER, AND RAIN WATER PIPING THAT ARE LOCATED IN EXISTING WALLS TO BE 6, EXISTING BUILDING SEWERS THAT ARE USED WITH NEW BUILDING SANITARY SEWERS """ww'_---- -i- HOSE BIBB 3.13 RESET SPRINKLER HEADS FROM UPRIGHT POSITION TO DOWN POSITION DEMOLISHED AND REMAINING IN SERVICE AFTER CONSTRUCTION SHALL BE RELOCATED TO NEW WALLS, CHASES, JLC 17.0258.00 FD ® FLOOR DRAIN E. SUBSTITUTIONS REQUESTED ON THE BID PROPOSAL FORM WHICH TO CENTER OF NEW CEILING TILE: ETC. SHALL BE EXAMINED AND TESTED TO CONFORM IN ALL RESPECTS TO ALL THE ARE PRIOR APPROVED BY THE ENGINEER WILL BE INCORPORATED REQUIREMENTS OF PLUMBING AUTHORITY HAVING JURISDICTION AND APPLICABLE INTO THE CONTRACT WITH THE SUCCESSFUL BIDDER. PLUMBING CODES. HD O HUB DRAIN 3.14 TORQUE ALL HUBLESS CAST IRON COUPLING IN STRICT ACCORDANCE 32. COORDINATE WITH GENERAL CONTRACTOR TO PATCH ALL EXISTING WALLS, FLOORS, CEILINGS, ETC., AS REQUIRED _F. REQUESTS FOR ANY SUBSTITUTIONS NOT SUBMITTED AND APPROVED WITH THE MANUFACTURERS RECOMMENDATIONS. UTILIZE COUPLING BY NEW WORK. SEE SPECIFICATIONS. TD ® TRENCH DRAIN MANUFACTURERS PRE-SET TORQUE WRENCH. 7. ALL EXISTING SANITARY, DOMESTIC WATER, AND RAIN WATER PIPING THAT ARE IN ACCORDANCE WITH THE ABOVE INSTRUCTIONS WILL BE DENIED BY 33. IT IS THE PLUMBING CONTRACTORS RESPONSIBILITY TO PROVIDE A DOUBLE CHECK VALVE BACKFLOW PREVENTION LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND REMAINING IN SERVICE AFTER THE ENGINEER. CONSTRUCTION SHALL BE RELOCATED TO NEW WALLS, CHASES, ETC. - - A-- - COMPRESSED AIR (BELOW GRADE) 3.15 INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH FIXTURE OR DEVICE ON THE MAIN DOMESTIC WATER SERVICE PROVIDED TO THE BUILDING/SPACE UNDER CONSTRUCTION AS PER BATTERY OF FIXTURES. ARRESTORS SHALL BE FACTORY FABRICATED. THE LATEST ADOPTED VERSION OF THE PLUMBING CODE EVEN IF THE BACKFLOW PREVENTION DEVICE IS NOT A COMPRESSED AIR ABOVE GRADE 1.5 REGULATORY REQUIREMENTS: 8. COORDINATE WITH GENERAL CONTRACTOR TO PATCH ALL EXISTING WALLS, FLOORS, ARRESTORS AND SIZE PER PLUMBING AND DRAINAGE INSTITUTE CALLED OUT SPECIFICALLY ON THE PLANS. ( ) A. ALL INSTALLATIONS. AND EQUIPMENT SHALL BE IN STRICT INSTALL ACEILINGS, ETC., AS REQUIRED BY NEW WORK. SEE SPECIFICATIONS ACCORDANCE WITH ALL APPLICABLE STATUTES, CODES AND STANDARD P.D.I. WH -201. ACCEPTABLE MANUFACTURERS ZURN, JOSAM, Adam Joseph Barney 0-- FLOOR CLEANOUT REGULATIONS OF THE GOVERNMENTAL BODIES HAVING JURISDICTION. SIOUX CHIEF. PPP INC. FOR 1-11 FU'S PROVIDE PDI -A, FOR 12-32 34. FIEF VERIFICATION OF EXISTING PIPING: ALL EXISTING PIPING SHOWN ON THE CONSTRUCTION DOCUMENTS IS P.E. #: 69124 0 CLEANOUT B. CONFORM TO 2014 FLORIDA PLUMBING CODE. FU'S PDI -B, 33-60 FU'S PDI -C, 61-113 FU'S PDI -D. BASED OFF OF VISUAL SITE INVESTIGATION AND AS BUILTS DRAWINGS OF THE EXISTING SITE AND BUILDINGC. CONFORM TO 2014 FLORIDA FIRE PREVENTION CODE. CONSTRUCTION. THE ENGINEER DOES NOT HAVE XRAY VISION. IT IS THE RESPONSIBILITY OF THE LICENSED EXTERIOR CLEANOUT D. CONFORM TO 2014 FLORIDA BUILDING CODE. PLUMBING CONTRACTOR TO FIELD VERIFY ALL EXISTING PIPING LOCATIONS, TYPES, SIZES, ELEVATIONS AND INVERTS. --[0]-- NOTIFY ENGINEER IF THE CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATE IN THE SPECIFICATIONS LEGENDS ����(� p_ �Or•�--+�C - PLUMBING T T T�/�T1�T( HORIZONTAL CLEANOUT 1.6 CUTTING AND PATCHING: PRIOR TO THE INITIATION OF ANY WORK. IDENTIFICATION AND VERIFICATION OF EXISTING PIPING TO BE LL J (X NOTES L.IJ 1v1BI v -� A. SUBMIT WRITTEN REQUEST IN ADVANCE OF CUTTING OR ALTERING ACCOMPLISHED BY THE FOLLOWING MEANS: ' ELEMENTS. • MANDATORY DYE TESTING OF ALL EXISTING SANITARY, STORM AND GREASE WASTE PIPING FOR SYSTEM R10" ITEMS TO BE REMOVED (DEMOLITION) IDENTIFICATION. B. EMPLOY SKILLED AND EXPERIENCED INSTALLER TO PERFORM • SNAKEALL SANITARY, STORM AND GREASE WASTE PIPING FOR A DISTANCE OF 100 FEET AND REPORT ANY SULLIVAN'S PUBLIC HOUSE CWN COLD NANO WATER CUTTING AND PATCHING WHICH EFFECT: BLOCKAGES• TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDING EQUIPMENT SUPPLIED OR TO BE B.1 STRUCTURAL INTEGRITY OF ELEMENT. 116 E FIRST STREET FW COLD FILTERED WATER B.2 INTEGRITY , MAINTENANCE, OR SAFETY OF ELEMENT. RD INSTALLED. B.3 EFFICIENCY, WEATHER. • ALL IDENTIFICATION AND VERIFICATION RESULTS SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW SANFOFL 32771 SHOCK ABSORBER B.4 VISUAL QUALITIES OF SIGHT. PRIOR TO THE INITIATION OF ANY WORK. B.5 WORK OF OWNER OR SEPARATE CONTRACTOR. 100% CD; MILZARCH, LLC 01/31/18 /V, No. 33,x4 JERRY WALKER MILLS, SR. .w`- Adam J Barney 407.921.8795 MILZARCH GMAIL.COM SHEET NOTE: %0 ' STAT AP..' \�v' 2018.01.31 15:16:29-05'00' SYMBOLS SHOWN ON THIS PLUMBING LEGEND ARE FOR REFERENCE PURPOSES rvA� t� R0008314 P0.1 ONLY. ALL OF THESE SYMBOLS MAY NOT BE USED FOR THIS PROJECT. "°""°°"°"s'y"'"'""" " ""°" A+ J B y PE on mo D°iv °na prnme SamD 5nvwn •, 701 WEST Third Street Sanford Fl. 32771 i a " auee° ld 1111:ci d1h,1e1-11 mum b, , , DATES anr2011 SEAL REFERENCE NOTES: o O1 PROVIDE 1" INDIRECT WASTE TO FLOOR SINK 20 PROVIDE 1 1/2- INDIRECT WASTE TO FLOOR SINK 0 PROVIDE 2" INDIRECT WASTE TO FLOOR SINK ® 2 INCH TANK VENT 5 2 INCH OUTLET VENT 60 FURNISH AND INSTALL ROTATIONALLY MOLDED POLYETHYLENE GREASE INTERnEPTOR FOR BELOW—GROUND INSTALLATION. INTERCEPTOR SHALL BE RATED FOR 7570 GALLONS OF TOTAL STORAGE CAPACITY. PROVIDE COMPLETE WITH MODEECA—TZ-29 EXTENSION COLLAR. GREASE TRAP SHALL BE TRAPZILLA MODEL OR EQUAL 7 TWO—WAY CLEAN—OUT — TYPICAL ® RUN 2 INCH VENT LINE UP WALL TO MINIMUM 7 FT ABOVE GRADE AND TERMINATE WITH GOOSENECK AND INSECT SCREEN O TERMINATE VENT PIPING THROUGH WALL AT MINIMUM 7 FEET ABOVE GRADE AND TERMINATE WITH ELBOW AND INSECT SCREEN 10 4 INSANITARY BELOW -GRADE. CONNECT TO EXISTING 11 FURNISH AND INSTALL ROTATIONALLY MOLDED POLYETHYLENE WATER SAMPLING PORT FOR BELOW—GROUND INSTALLATION. SAMPLING PORT SHALL HAVE FULLY REMOVABLE SELF—POSITIONING KEYED COVER EQUIPPED WITH BRASS FASTENERS FOR SAMPLING ACCESS. PROVIDE COMPLETE WITH MODEL ECA—TZ-29 EXTENSION COLLAR. SAMPLING PORT SHALL BE TRAPZILLA MODEL TZSP-40—ECA OR EQUAL 12 ROUTE 3 -COMPARTMENT SINK WASTE THROUGH FREE—STANDING FINE PARTICLE STRAINER PRIOR TO DISCHARGING OVER FLOOR SINK. FINE PARTICLE STRAINER SHALL BE AS MANUFACTURED BY "ENVIRONMENTAL BIOTECH" OR CITY APPROVED EQUAL. STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. FLOOR PLAN - PLUMBING - WASTE AND VENT Scale: 1/4 = 1'-0 PUMP SCHEDULE FIXTURE SCHEDULE MARK FIXTURE WASTE TRAP CONN. SIZE MOTOR DATA SELECTION BASED ON: MANUFACTURER /MODEL # UNIT # DESCRIPTION TYPE GPM ppFF e P% E 2" 1" - REMARKS INLET OUTLET WATTS RPM VOLT PH. MANUFACTURER MODEL HWC-1 HOT WATER RECIRCULATIO IN LINE PUMP 1 60 3/4 3/4 41 2800 120 1 PH BELL AND GOSSETT NBF-9U/LW 1. CLOSED COMBUSTION _F PUMP 150,000 169 120V - 1 0 WHITE SEAT. L-1 LAVATORY - ADA TYPE 1-1/2' 1-1/4" 1-1/2" 1/2' 1/2" AMERICAN STANDARD NOTES: 1. PROVIDE WITH AUTOMATIC TIMER KIT MODEL TC -1 REFERENCE NOTES: o O1 PROVIDE 1" INDIRECT WASTE TO FLOOR SINK 20 PROVIDE 1 1/2- INDIRECT WASTE TO FLOOR SINK 0 PROVIDE 2" INDIRECT WASTE TO FLOOR SINK ® 2 INCH TANK VENT 5 2 INCH OUTLET VENT 60 FURNISH AND INSTALL ROTATIONALLY MOLDED POLYETHYLENE GREASE INTERnEPTOR FOR BELOW—GROUND INSTALLATION. INTERCEPTOR SHALL BE RATED FOR 7570 GALLONS OF TOTAL STORAGE CAPACITY. PROVIDE COMPLETE WITH MODEECA—TZ-29 EXTENSION COLLAR. GREASE TRAP SHALL BE TRAPZILLA MODEL OR EQUAL 7 TWO—WAY CLEAN—OUT — TYPICAL ® RUN 2 INCH VENT LINE UP WALL TO MINIMUM 7 FT ABOVE GRADE AND TERMINATE WITH GOOSENECK AND INSECT SCREEN O TERMINATE VENT PIPING THROUGH WALL AT MINIMUM 7 FEET ABOVE GRADE AND TERMINATE WITH ELBOW AND INSECT SCREEN 10 4 INSANITARY BELOW -GRADE. CONNECT TO EXISTING 11 FURNISH AND INSTALL ROTATIONALLY MOLDED POLYETHYLENE WATER SAMPLING PORT FOR BELOW—GROUND INSTALLATION. SAMPLING PORT SHALL HAVE FULLY REMOVABLE SELF—POSITIONING KEYED COVER EQUIPPED WITH BRASS FASTENERS FOR SAMPLING ACCESS. PROVIDE COMPLETE WITH MODEL ECA—TZ-29 EXTENSION COLLAR. SAMPLING PORT SHALL BE TRAPZILLA MODEL TZSP-40—ECA OR EQUAL 12 ROUTE 3 -COMPARTMENT SINK WASTE THROUGH FREE—STANDING FINE PARTICLE STRAINER PRIOR TO DISCHARGING OVER FLOOR SINK. FINE PARTICLE STRAINER SHALL BE AS MANUFACTURED BY "ENVIRONMENTAL BIOTECH" OR CITY APPROVED EQUAL. STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. FLOOR PLAN - PLUMBING - WASTE AND VENT Scale: 1/4 = 1'-0 PLUMBING FIXTURE SCHEDULE MARK FIXTURE WASTE TRAP VENT COLD WATER HOT WATER MANUFACTURER /MODEL # DESCRIPTION WC -1 WATER CLOSET - ADA TYPE 3" INTEG 2" 1" - AMERICAN STANDARD TANK TYPE - RIM 17" AFF, VITREOUS CHINA, 1.6 GPF, SIPHON JET, ELONGATED BOWL, ® 100•F RISE CURRENT DRAW (LBS.) DIMENSIONS MANUFACTURER MODEL # 2467.016 FLOOR MOUNTED, CLOSED COUPLED COMBINATION; BOLT CAPS. ANGLE STOP SUPPLIES & PER PHASE ESCUTCHEONS. COORDINATE FINISH WITH ARCHITECT. SOLID PLASTIC, OPEN FRONT ELONGATED GWH-1 ALL CLOSED COMBUSTION _F 60 150,000 169 120V - 1 0 WHITE SEAT. L-1 LAVATORY - ADA TYPE 1-1/2' 1-1/4" 1-1/2" 1/2' 1/2" AMERICAN STANDARD WHEELCHAIR ACCESSIBLE, VITREOUS CHINA, WHITE, WALL HUNG, FRONT OVERFLOW. NOTES: 9140.047 COMPLETE WITH STOPS AND TRAP. PROVIDE WITH AMERICAN STANDARD FAUCET. NOTES: 1. PROVIDE WITH THERMAL EXPANSION TANK, REFERENCE NOTES: o O1 PROVIDE 1" INDIRECT WASTE TO FLOOR SINK 20 PROVIDE 1 1/2- INDIRECT WASTE TO FLOOR SINK 0 PROVIDE 2" INDIRECT WASTE TO FLOOR SINK ® 2 INCH TANK VENT 5 2 INCH OUTLET VENT 60 FURNISH AND INSTALL ROTATIONALLY MOLDED POLYETHYLENE GREASE INTERnEPTOR FOR BELOW—GROUND INSTALLATION. INTERCEPTOR SHALL BE RATED FOR 7570 GALLONS OF TOTAL STORAGE CAPACITY. PROVIDE COMPLETE WITH MODEECA—TZ-29 EXTENSION COLLAR. GREASE TRAP SHALL BE TRAPZILLA MODEL OR EQUAL 7 TWO—WAY CLEAN—OUT — TYPICAL ® RUN 2 INCH VENT LINE UP WALL TO MINIMUM 7 FT ABOVE GRADE AND TERMINATE WITH GOOSENECK AND INSECT SCREEN O TERMINATE VENT PIPING THROUGH WALL AT MINIMUM 7 FEET ABOVE GRADE AND TERMINATE WITH ELBOW AND INSECT SCREEN 10 4 INSANITARY BELOW -GRADE. CONNECT TO EXISTING 11 FURNISH AND INSTALL ROTATIONALLY MOLDED POLYETHYLENE WATER SAMPLING PORT FOR BELOW—GROUND INSTALLATION. SAMPLING PORT SHALL HAVE FULLY REMOVABLE SELF—POSITIONING KEYED COVER EQUIPPED WITH BRASS FASTENERS FOR SAMPLING ACCESS. PROVIDE COMPLETE WITH MODEL ECA—TZ-29 EXTENSION COLLAR. SAMPLING PORT SHALL BE TRAPZILLA MODEL TZSP-40—ECA OR EQUAL 12 ROUTE 3 -COMPARTMENT SINK WASTE THROUGH FREE—STANDING FINE PARTICLE STRAINER PRIOR TO DISCHARGING OVER FLOOR SINK. FINE PARTICLE STRAINER SHALL BE AS MANUFACTURED BY "ENVIRONMENTAL BIOTECH" OR CITY APPROVED EQUAL. STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. FLOOR PLAN - PLUMBING - WASTE AND VENT Scale: 1/4 = 1'-0 `Illi a lil�iiir \ aPM �IFBgR�F,,�� , No. 69124 - -0 ce Adam J Barney STATE of �w2018.02.26 16:40:21-05'00' 'sS/NAV. IFN Thls Item has bona 111—nlcnlly WgInd and nonlad by ndnm J. Barney, PE on Iha oam arMlor nmo 911 drown using a dipnni spnnlwo. Printed c,pl,, of thla d—Z, aze nolmnsidnrcd slgnad and saslad antl tha eIgnnlura..& be vnrill,d on any elaolronlc ooplas Joseph, Loweence & Co Consulfinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG,COM CA NO. 28730 JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 GAS WATER HEATER SCHEDULE BTU GPH REC. VOLT/PHASE WEIGHT MANUFACTURER UNIT # SERVING TYPE GALLONS INPUT ® 100•F RISE CURRENT DRAW (LBS.) DIMENSIONS MANUFACTURER MODEL # PER PHASE GWH-1 ALL CLOSED COMBUSTION _F 60 150,000 169 120V - 1 0 570 57" H x 28" 0 BRADFORD WHITE EF-60T-150E-3X(A) - PROPANE GAS NOTES: 1. PROVIDE WITH THERMAL EXPANSION TANK, MINIMUM 0.9 GALLON ACCEPTANCE, 2.0 GALLON TOTAL VOLUME. THEM-X-TROL MODEL ST -5 OR EQUAL 2. COORDINATE WATER HEATER VENTING WITH MECHANICAL PLANS. 3. WATER HEATER SHALL BE CONFIGURED FOR PROPANE GAS USE `Illi a lil�iiir \ aPM �IFBgR�F,,�� , No. 69124 - -0 ce Adam J Barney STATE of �w2018.02.26 16:40:21-05'00' 'sS/NAV. IFN Thls Item has bona 111—nlcnlly WgInd and nonlad by ndnm J. Barney, PE on Iha oam arMlor nmo 911 drown using a dipnni spnnlwo. Printed c,pl,, of thla d—Z, aze nolmnsidnrcd slgnad and saslad antl tha eIgnnlura..& be vnrill,d on any elaolronlc ooplas Joseph, Loweence & Co Consulfinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG,COM CA NO. 28730 JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 i. III t I li 1 1 FLOOR PLAN -PLUMBING -WASTE AND VENT 1 Scale: 1l4 = 1'-0" MEZZANINE FLOOR PLAN- MECHANICAL Scale: 1/4 = 1'-0" HOT WATER RECIRC. PUMP HWCP-1 SEE SCHEDULE AND DETAIL. SEE FLOOR PLAN FOR PIPE SIZES. VACUUM RELIEF VALVE G BALL VALVE (TYP.) DIRECT VENT FLUE EXHAUST SEE MECH. DWGS. UNION (TYPICAL) T C TEMP. & PRESS. RELIEF VALVE (TYPICAL) WATER HEATER GWH-1 SEE SCHEDULE. DIRECT VENT FLUE INTAKE SHUT-OFF COCK & REGULATOR SEE MECH. DWGS. PER MFG. REQMTS. PIPE RELIEF VALVE PIPING MIN. 1" DIA. DRIPLEGAA-i F- -:D � DOWN TO FIRST FLOOR AND ��''�•. I 13 l SPILL OVER FLOOR SINK DRAIN VALVE LJ ADJACENT TO 3 -COMPARTMENT SINK .DRAIN PAN -�-THERMAL EXPANSION TANK _3 GAS WATER HEATER DETAIL NTS REFERENCE NOTES: o 0 PROVIDE UNDER SINK TRAP PRIMER ON LAVATORY AND PIPE TO FLOOR DRAIN AND CORRESPONDING RESTROOM. PRECISION PLUMBING PRODUCTS MODEL PR01-ULP500 O PROVIDE ASSE 1070 APPROVED THERMOSTATIC MIXING VALVE BELOW LAVATORY TO LIMIT HOT WATER TEMPERATURE TO 110 DEGREES FAHRENHEIT MAXIMUM �3 PROVIDE ASSE 1070 APPROVED THERMOSTATIC MIXING VALVE BELOW HAND SINK TO LIMIT HOT WATER TEMPERATURE TO 110 DEGREES FAHRENHEIT MAXIMUM OPROVIDE NEW LIQUID PROPANE TANK TO SERVE GAS FIRED KITCHEN EQUIPMENT. COORDINATE EXACT SIZE AND LOCATION WITH LOCAL PROPANE PROVIDER. MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH NFPA 58: LIQUEFIED PETROLEUM GAS CODE. PROVIDE VENTED PRESSURE REGULATORS AT EACH PIECE OF EQUIPMENT AT AS REQUIRED TO DELIVER MANUFACTURER SPECIFIED PRESSURE. 0 SHUT-OFF VALVE AND WATER METER IN CAST IRON ACCESS BOX FLUSH WITH PAVEMENT. © 1 1/4" POTABLE CW SUPPLY BELOW GRADE. 1/2" COLD WATER UP TO ICE -MAKER WITH FILTER. PROVIDE DUAL CHECK VALVE WITH ATMOSPHERIC VENT IN SUPPLY LINE. PIPE DRAIN LINE TO HUB DRAIN. 0 1 1/2" COLD WATER, 1 1/2" HOT WATER AND 3/4" HOT WATER RETURN UP WATER HEATER ON MEZZANINE �\CENSp '•F� `~ P No. 69124 J Adam J Barney ^, A '• = p STATE o� 2018.01.31 15:17:40-05'00' ' :• .�' ttr ONAL This item hes been electronically signed and sealed by Adam J. Barney, PE on the Data and/or Tim. Slamp ahc- using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on env aleclmnic copies CSC JosepL, Lawrence & Co Consulting Engineers 1180 HARWOOD AYE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 WWW.JLCENG.COM CA NO. 28730 JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 PROPANE GAS RISER DIAGRAM NOT TO SCALE FCO <' I 2 ` „ FS 3' FS 2" I \\ 4„ WC -1 3" FS „ 2" FD 2" FCO i WC -1 3"2 " FD ECO 3" (200 CFH) ��' I 3" 3/4" (3 LF) 4" (35 CFH) ECO fmi PROPANE TANK BY O LOCAL PROPANE ij�\\\\ //��> 4" 3/4" (24 LF) PROVIDER IECO3„ GREASE INTERCEPTOR 4" w ( 9WAST�ER ISER DIAGRAM NO I 10 SCALE PLING PORT WC -1 1/201 3/400 Jw t 'jw 1 1/2" HOT, 1 1/2" COLD AND 3/4" RETURN UP TO \ 3/4" WATER HEATER ON MEZZANINE. SEE WATER HEATER /' /' PIPING DETAIL FOR CONTINUATION. 1 /'' �-/ Joseph, Lawrence 8C Co Consultinq Engineers 1 1/4" 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 /- TEL: 321.972.4466 W M CA NO, 28130 1 1/2" /-��� JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 R NIRP T)T A C,R A AS Q% WATER RISER DIAGRAM NOT TO SCALE \ 0\� 1111111/// M J BAR No. 69124 Adam J Barney �`0FTATE OF =4,�; 2018.02.26 16:40:42-05'00' Tors lam has h..n ol.drpnicalty aignstl end eael.d d, Ad.m J. eam.y, PE .n tha Del. nW., Tuna St.mpah— a,In-digital stg,—o. Prinled c,pla, of this d .... —era not Wnald.r.d sipn.d end sealed end the eJglltll mall he —lllad., any aleclronic wnina GAS EQUIPMENT LOAD EQUIPMENT QTY. CFH CFH RANGE 9� 1 35 35 FRYER 10 1 200 200 TOTAL GAS LOAD = 235 CFM GAS PIPING BASED ON TABLE 402.4(28) FLORIDA FUEL GAS CODE — UNDILUTED PROPANE — INLET PRESSURE 11.0 IN. W.C., 0.5 IN. W.C. PRESSURE DROP, SPECIFIC GRAVITY 1.50 - TOTAL PIPE LENGTH OF 40 LF. PROPANE GAS RISER DIAGRAM NOT TO SCALE FCO <' I 2 ` „ FS 3' FS 2" I \\ 4„ WC -1 3" FS „ 2" FD 2" FCO i WC -1 3"2 " FD ECO 3" (200 CFH) ��' I 3" 3/4" (3 LF) 4" (35 CFH) ECO fmi PROPANE TANK BY O LOCAL PROPANE ij�\\\\ //��> 4" 3/4" (24 LF) PROVIDER IECO3„ GREASE INTERCEPTOR 4" w ( 9WAST�ER ISER DIAGRAM NO I 10 SCALE PLING PORT WC -1 1/201 3/400 Jw t 'jw 1 1/2" HOT, 1 1/2" COLD AND 3/4" RETURN UP TO \ 3/4" WATER HEATER ON MEZZANINE. SEE WATER HEATER /' /' PIPING DETAIL FOR CONTINUATION. 1 /'' �-/ Joseph, Lawrence 8C Co Consultinq Engineers 1 1/4" 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 /- TEL: 321.972.4466 W M CA NO, 28130 1 1/2" /-��� JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 R NIRP T)T A C,R A AS Q% WATER RISER DIAGRAM NOT TO SCALE \ 0\� 1111111/// M J BAR No. 69124 Adam J Barney �`0FTATE OF =4,�; 2018.02.26 16:40:42-05'00' Tors lam has h..n ol.drpnicalty aignstl end eael.d d, Ad.m J. eam.y, PE .n tha Del. nW., Tuna St.mpah— a,In-digital stg,—o. Prinled c,pla, of this d .... —era not Wnald.r.d sipn.d end sealed end the eJglltll mall he —lllad., any aleclronic wnina ' ...0 _ 3 IN. (76 MM) , "Em�� MIN. PERIMETER \ Pn A ` � �� t OVERLAP ON \\ OUTSIDE LAYER \\ ` 1 \\ 2 x 2 x 1/8 IN. MIN. \\ ANGLE \\ \\\\\ 1/2 IN. (13 MM) MIN. CARBON OR STAINLESS STEEL BANDING �1\ - 0.015 IN. MIN. THICKNESS TYPICAL - PLACED AT 10-1/2 IN. SPACING AND CENTERED OVER OVERLAPS "ON1\ Note: Lobel Required 3 IN. (76 MM) Access oor MIN. 1 Do Not Obstnint LONGITUDINAL ' OVERLAP ON OUTSI E LAYER TIGHT FIREMASTER F2-HT-XL3 DOOR SYSTEM COMPRESSION JOINT ON INSIDE LAYER 1. THERMAL CERAMICS FIREMASTER FASTWRAP'XL OR PYROSCAT XL HAS BEEN TESTED IN ACCORDANCE WITH ASTM E2336 TO PROVIDE ZERO CLEARANCE TO COMBUSTIBLES AND MEETS THE REQUIREMENTS FOR ONE OR TWO HOUR ENCLOSURES. THROUGH PENETRATIONS FIRESTOP SYSTEMS ARE TESTED IN ACCORDANCE WITH EITHER ASTM E 814 OR UL 1479. ICC -ES APPROVAL PER REPORT ESR 2213 OR ESR 2832. UNDERWRITER'S LABORATORIES (UL) LISTINGS SHOW COMPLIANCE TO UL 1479 FOR THROUGH PENETRATION FIRESTOP SYSTEMS. 2. INSULATION APPLIED IN TWO LAYERS WITH TIGHT COMPRESSION JOINT ON INSIDE LAYER AND 3 INCH MINIMUM OVERLAPS ON BOTH PERIMETER AND LONGITUDINAL OVERLAPS ON OUTSIDE LAYER. 3. GREASE EXHAUST DUCT RUNS FROM THE HOOD EXHAUST CONNECTION UP TO THE EXHAUST FAN ON THE ROOF WITH MINIMAL TURNS OR BENDS AND MAINTAINING MINIMUM 1" UNIT VERTICAL RISE PER 12 UNITS HORIZONTAL RUN. NFPA 96 COMPLIANT ACCESS DOORS LOCATED AS REQUIRED BY CODE, 4. THERMAL CERAMICS FIREMASTER ACCESS DOORS AS SPECIFIED IN ICC -ES BUILDING CODE REPORTS ESR 2213 OR ESR 2832. 5. ROOF MOUNTED EXHAUST FAN IS MOUNTED ON A HINGED BASE WHICH ALLOWS ACCESS TO THE DUCT FROM THE ROOF. 6. SUPPORT HANGER SYSTEMS DO NOT NEED TO BE WRAPPED PROVIDED THE HANGER RODS ARE AT LEAST A MINIMUM OF 3/8 IN. DIAMETER. USE MINIMUM 2 X 2 X 1/8 IN. STEEL ANGLE OR SMACNA EQUIVALENT SUPPORT SYSTEM. 7. THERMAL CERAMICS DUCT ENCLOSURE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 8. THERMAL CERAMICS DUCT WRAP SHALL BE INSTALLED ON THE DUCT FROM THE HOOD CONNECTION TO THE CONNECTION TO THE FAN. `2� GREASE EXHAUST DUCT PROTECTION "Ts TO COMBUSTIBLES DETAIL NE EF (WITH PHENOLIC COATING FLEXIBLE CONNECTI WEATHER PROOF ENCLOSURE NCOPRENC ISOLATORS ------------- FLASH AND ROOF ------------ - IN SUPPORT. EXISTING DECK PRESSURE TREATED 4X8 SUPPORT AND INSULATION TO SPAN EXISTING JOISTS EXHAUST FAN INSTALLATION DETAIL NTS PLACE ON DUCK SUPPORT RACK. SEE DETAIL 2 ON SHEET, III 16GA. WELDED EXHAUST GREASE DUCT (TYP.) L> d" GRADE 304 STAINLESS STEEL CABLE SUPPORTING DUCT. SEE DETAIL 2 ON SHEET M4.1. U.L. LISTED - ACCESS PANEL THERMAL CERAMICS FIREMASTER FASTWRAP XL OR EQUAL. SEE DETAIL REMOVABLE GREASE FILTER W/ HANDLES AUTO FIRE EXTINGUISHER (SEPARATE PERMIT BY FIRE EXTINGUISHER CO.) MTL. WALL FLASHING 24 GA. S/S SHEET MTL. 6" TYP. 0 ALL OPEN SIDES 1 NTS FIN. FLOOR NOTE: CONTRACTOR TO FIELD VERIFY EXACT ROUTING WITH STRUCTURE PRIOR TO FABRICATION (TYP) PROTECT OUTDOOR DUCTS AGAINST CORROSION \ DUCT TO BE FASTENED IN EXTERIOR WALL WITH CAPTIVEAIRE VERTICAL SUPPORT CLAMPS. SEE DETAIL ON SHEET M4.3. _- 2 vIUIPCTT'TT' DENETRAT ON.FSEE DETAIN 3 0 NRSHEETALL M4.3 1/4" SLOPE PER 3" MIN. --I COOKING EQUIPMENT BY OTHERS GREASE HOOD SECTION `— 5/8" TYPE "X" GYP. BD. ALL AROUND DUCT (FIRE RATED SHAFT PER BLDG CODE) IF REQUIRED 5" 3" MIN. 20 STUD WALL W/ 5/8" TYPE "X" GYP. -BD. ON BOTH SIDE \\�1�11flllll/��, No. 69124 o Adam J Barney 0•. STATE OF Z4/2018.03.01 15:27:01-05'00' -ir �` '' •. FC ORI D P. •'' �\� !ONAI- 1E .�. This Item has been elodronically signed end sealed by Adam J. gamey, PE on the Data d1a, Time Stamp shown Wing is dlgltel slgnst— P,letad ooples of this comment em not coneldisad signed and sealed and the slgnamre maA be -00 he any aI.M. to ndplaa ® 1 Cx Joseph, Lawrence & Co Consultinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG.COM CA NO, 28730 JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 Sp FLOW 16 5�P U 12" LONG TRANSITION AS REQUIRED NOTE: OUTSIDE AIR DUCT INSTALL PIPING, CONDUITS, AND DUCTWORK TO ALLOW SPACE FOR REMOVAL OF FILTERS AND SERVICING OF UNIT. MOTORIZED DAMPER .d9m DRAIN PAN: MINIMUM 2" DEEP AND NOT LESS THAN 3" THAN UNIT OR R COIL DIMENSIONS INRWIDTH AND LENGTH 3/4" CONDENSATE DRAIN - ROUTE AIR TO DRYWELL. SEE HVAC PLAN FOR ON LOCATION. REQ SUCTION LINE AND LIQUID LINE - CONNECT TO CONDENSING UNIT. 3/4" AUXILIARY DRAIN PAN DRAIN. AUXILIARY DRAIN PAN WITH FLOAT SWITCH TO SHUT 2" NEOPRENE DOWN UNIT. ISOLATION PAD HB DRAIN (---4 HORIZONTAL AHU DETAIL �Ts ' ...0 _ 3 IN. (76 MM) , "Em�� MIN. PERIMETER \ Pn A ` � �� t OVERLAP ON \\ OUTSIDE LAYER \\ ` 1 \\ 2 x 2 x 1/8 IN. MIN. \\ ANGLE \\ \\\\\ 1/2 IN. (13 MM) MIN. CARBON OR STAINLESS STEEL BANDING �1\ - 0.015 IN. MIN. THICKNESS TYPICAL - PLACED AT 10-1/2 IN. SPACING AND CENTERED OVER OVERLAPS "ON1\ Note: Lobel Required 3 IN. (76 MM) Access oor MIN. 1 Do Not Obstnint LONGITUDINAL ' OVERLAP ON OUTSI E LAYER TIGHT FIREMASTER F2-HT-XL3 DOOR SYSTEM COMPRESSION JOINT ON INSIDE LAYER 1. THERMAL CERAMICS FIREMASTER FASTWRAP'XL OR PYROSCAT XL HAS BEEN TESTED IN ACCORDANCE WITH ASTM E2336 TO PROVIDE ZERO CLEARANCE TO COMBUSTIBLES AND MEETS THE REQUIREMENTS FOR ONE OR TWO HOUR ENCLOSURES. THROUGH PENETRATIONS FIRESTOP SYSTEMS ARE TESTED IN ACCORDANCE WITH EITHER ASTM E 814 OR UL 1479. ICC -ES APPROVAL PER REPORT ESR 2213 OR ESR 2832. UNDERWRITER'S LABORATORIES (UL) LISTINGS SHOW COMPLIANCE TO UL 1479 FOR THROUGH PENETRATION FIRESTOP SYSTEMS. 2. INSULATION APPLIED IN TWO LAYERS WITH TIGHT COMPRESSION JOINT ON INSIDE LAYER AND 3 INCH MINIMUM OVERLAPS ON BOTH PERIMETER AND LONGITUDINAL OVERLAPS ON OUTSIDE LAYER. 3. GREASE EXHAUST DUCT RUNS FROM THE HOOD EXHAUST CONNECTION UP TO THE EXHAUST FAN ON THE ROOF WITH MINIMAL TURNS OR BENDS AND MAINTAINING MINIMUM 1" UNIT VERTICAL RISE PER 12 UNITS HORIZONTAL RUN. NFPA 96 COMPLIANT ACCESS DOORS LOCATED AS REQUIRED BY CODE, 4. THERMAL CERAMICS FIREMASTER ACCESS DOORS AS SPECIFIED IN ICC -ES BUILDING CODE REPORTS ESR 2213 OR ESR 2832. 5. ROOF MOUNTED EXHAUST FAN IS MOUNTED ON A HINGED BASE WHICH ALLOWS ACCESS TO THE DUCT FROM THE ROOF. 6. SUPPORT HANGER SYSTEMS DO NOT NEED TO BE WRAPPED PROVIDED THE HANGER RODS ARE AT LEAST A MINIMUM OF 3/8 IN. DIAMETER. USE MINIMUM 2 X 2 X 1/8 IN. STEEL ANGLE OR SMACNA EQUIVALENT SUPPORT SYSTEM. 7. THERMAL CERAMICS DUCT ENCLOSURE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 8. THERMAL CERAMICS DUCT WRAP SHALL BE INSTALLED ON THE DUCT FROM THE HOOD CONNECTION TO THE CONNECTION TO THE FAN. `2� GREASE EXHAUST DUCT PROTECTION "Ts TO COMBUSTIBLES DETAIL NE EF (WITH PHENOLIC COATING FLEXIBLE CONNECTI WEATHER PROOF ENCLOSURE NCOPRENC ISOLATORS ------------- FLASH AND ROOF ------------ - IN SUPPORT. EXISTING DECK PRESSURE TREATED 4X8 SUPPORT AND INSULATION TO SPAN EXISTING JOISTS EXHAUST FAN INSTALLATION DETAIL NTS PLACE ON DUCK SUPPORT RACK. SEE DETAIL 2 ON SHEET, III 16GA. WELDED EXHAUST GREASE DUCT (TYP.) L> d" GRADE 304 STAINLESS STEEL CABLE SUPPORTING DUCT. SEE DETAIL 2 ON SHEET M4.1. U.L. LISTED - ACCESS PANEL THERMAL CERAMICS FIREMASTER FASTWRAP XL OR EQUAL. SEE DETAIL REMOVABLE GREASE FILTER W/ HANDLES AUTO FIRE EXTINGUISHER (SEPARATE PERMIT BY FIRE EXTINGUISHER CO.) MTL. WALL FLASHING 24 GA. S/S SHEET MTL. 6" TYP. 0 ALL OPEN SIDES 1 NTS FIN. FLOOR NOTE: CONTRACTOR TO FIELD VERIFY EXACT ROUTING WITH STRUCTURE PRIOR TO FABRICATION (TYP) PROTECT OUTDOOR DUCTS AGAINST CORROSION \ DUCT TO BE FASTENED IN EXTERIOR WALL WITH CAPTIVEAIRE VERTICAL SUPPORT CLAMPS. SEE DETAIL ON SHEET M4.3. _- 2 vIUIPCTT'TT' DENETRAT ON.FSEE DETAIN 3 0 NRSHEETALL M4.3 1/4" SLOPE PER 3" MIN. --I COOKING EQUIPMENT BY OTHERS GREASE HOOD SECTION `— 5/8" TYPE "X" GYP. BD. ALL AROUND DUCT (FIRE RATED SHAFT PER BLDG CODE) IF REQUIRED 5" 3" MIN. 20 STUD WALL W/ 5/8" TYPE "X" GYP. -BD. ON BOTH SIDE \\�1�11flllll/��, No. 69124 o Adam J Barney 0•. STATE OF Z4/2018.03.01 15:27:01-05'00' -ir �` '' •. FC ORI D P. •'' �\� !ONAI- 1E .�. This Item has been elodronically signed end sealed by Adam J. gamey, PE on the Data d1a, Time Stamp shown Wing is dlgltel slgnst— P,letad ooples of this comment em not coneldisad signed and sealed and the slgnamre maA be -00 he any aI.M. to ndplaa ® 1 Cx Joseph, Lawrence & Co Consultinq Engineers 1180 HARWOOD AVE., SUITE 3000 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 321.972.4466 W W W.JLCENG.COM CA NO, 28730 JLC 17.0258.00 Adam Joseph Barney P.E. #: 69124 DUCT INFORMATION TABLE Duct Diameter DIM"A" DIM "B" DIM "C" Part Number Part Number 81, 10.194 4.099 13.694 DW08VESU DW08VESU18 10 12.194 5.099 15.694 DW10VESU DW10VESU18 POLYURETHANE SEALANT 12" 14.194 6.099 17.694 DW12VESU DW12VESU18 14" 16.194 7.099 19.694 DW14VESU DW14VESU16 FASTENERS WITH NEOPRENE 16" 18.194 8.099 21.694 DW16VESU DW16VESU18 WASHERS 0 8" O.C. MIN. 18" 20.194 9.099 23.694 DW18VESU DW18VESU18 Unlnsulated duct must be 20" 22,194 10.099 25,694 DW20VESU DW20VESU18 24" 26.194 12.099 29.694 DW24VESU DW 44VESU18 18" from combustible surface. 20 G.A. STAINLESS STEEL SHEET METAL COUNTER FLASHING DUCT METAL FLASHING PIECE. DWxxsUBR. 5/16-18 FILL ANNULAR SPACE WITH Mounting Hardware "A" Supplied By others, BACKER ROD AND SEALANT DIM- . y ' DETAIL A i SCALE 1 :6 Duct, h: .; e.., ; ° Open wail, solid wall, MECHANICAL FASTENER �:. y... 20 G.A. STAINLESS STEEL SHEET METAL 5/16 x 4° . WITH NEOPRENE WASHER °°. ° Toggle Bolt ENCLOSURE WITH HEMMED EDGE, TO ° ° (8) PCSSON CURB SIDE ONLY „ EXTEND A MIN. OF 6 IN ON BOTH THE DIM llCg , under v Support DUCT AND THE VERTICAL SURFACE. ENCLOSURE TO BE MADE OF ONE PIECE .° • ° ° �� ,. WITH THE SEAM CENTERED ON THE Strut. Y� y �' , BOTTOM OF THE DUCT AND OVERLAPPED °°° DIM tlBlt o en wail: �i �'� A MINIMUM OF 6". Wall Support p DOUBLE SIDED BUTYL TAPE' DWSUBRB (2) PLC'S, Bracket, 1- DWSUBRD (2) PLC's - 18" CLEARANCE, 5/16 x 4" Long Duct, DWSUBRF 2 PLC'S 18" CLEARANCE 20 & 24. Toggle Bolts Are O Washer (8) PCS'S. Used To Secure I NEW DUCTWORK Support To Open DWSUBRA (6) PLC'S. Walls, Hardware Provided, rl :, DWSUPPLATE (4) PLC'S, DWSUBRC (2) PLC'S, DwsuBRE (2) PLC'S. .. . . NEW BASE FLASHING TWO-PIECE COUNTER FLASHING ° ° BEHIND SHEET METAL DUCT FLASHING Vertical Support 3 DUCT T H R U EXTERIOR WALL °, VARIABLE DIM under v Clamp. ° o. .o r�rs PENETRATION DETAIL --+�-� VARIABLE DIM VARIABLE DIM a er a ; SteelZinc Coate Part Number: See Above unless atherwze specified Bank Size: N/ x A M COLA Number: ee Above Dimensions are in Inches. el .79ee Above s /p—� rawln ame Duct standard Tolerances are: r,./ N DEN 1 I / \ L Fractions ±xx± Drawn err Decimal .XX±,05 Parent Assembly:Ductro'ec�- xxx±.015 I.-CSheet: of Angles:±1* NOTE: ALL ROOF TOP EQUIPMENT AND SUPPORTS SHALL WIDTH OF EQUIPMENT_(IN) I HEORT OF LEGS BE SECURED TO THE STRUCTURE IN COMPLIANCE WITH THE LOADING REQUIREMENTS OF CHAPTER 16 (HIGH -VELOCITY HURRICANE ZONES) OUTSIDE DUCTWORK 2" WIDE 10" GAGE STRAP 1" X 1" X " ANGLE IRON CHANNEL X 2" X 2" ON TOP OF TRUSS CHORD. ALUMINUM MIN: 3'x3" THICKNESS:1/2" ANGLE SECURE ANGLE TO VERTICAL _ - ALUMINUM STAND AS MANUFACTURED BY ° POST WITH 2 -#10 SELF _ _ (g( PRECISION ALUMINUM PRODUCTS OR TAPPING SCREWS EQUIVALENT. INSTALL AND ADJUST PER = _ MANUFACTURER'S RECOMMENDATIONS. 1.5" ROUND - Joseph, Lawrence 8c Cc SECURE STRAP TO TUBING __ - Consulting Engineers ANGLE WITH 2-#10 1180 HARWOOD AVE., SUITE 3000 SELF TAPPING SCREWS 5" X 5" X _ _ TEL: 321.972.4466 ALTAMONTE SPRINGS FLORIDA 32714 BASE PLATE _ wwA NO, 1 731 1/2" ALL THREADED ROD CA No. 28730 S/S CLOSURE BY HOOD MFG. = BOLTED TO UNISTRUT gq,�,�� JLC 17.0258.00 REFER TO BELOW ANCHOR SCHEDULE--/- = HANGERS ON HOOD. MIN. 4 4P \GI -NSF NCC PLACES ON OVEN HOOD. — - No. 69124 _ ro Adam J Barney EXHAUST HOOD VERIFY SIZE & 0 ., STATE OF �w 2018.03.01 15:27:23-05'00' CONFIGURATION W/ MECHANICAL '�ss/oNAI_���� DRAWINGS '//t, l 11 1\\\ This Ilam hes Goan.1.01 hi Wily egnad and a 10 by ` Adam J.Barney, PE on the Dale.,dlor Tim. Stamp ahem Adam Joseph Barney using a dlglial signature, PrWad copW & thla d—eni are ,µ 1" net considered signed and ebalotl and the slgnAlure mudl be P.E. q/•, 69124 ,.,Iflod on eny minctronlc copies DETAILS MECHANICAL SULLIVAN'S PUBLIC HOUSE 1 MOOD MOUNTING DETAIL 116 E FIRST STREET Nrs SANFORD, FL 32771 100% CDs MILZARCH, LLC 01/31/18 (_2� DUCT SUPPORT RAC K DETAIL JERRY WALKER MILLS, SR. 0 PERMIT COMMENT RESPONSES 02/28/2018 2 �Ts 407.921.8795 MILZARCH@GMAIL.COM SHEE AR0008314 M4.3 701 WEST Third Street, Sanford, Fl. 32771 DATE: 8/I%1®11 SEAL ANCHOR SCHEDULE ANCHOR TY E OS T UCTU ANCHOR SCI N �"� SAE GRADE 5 SHEET METAL SCREWS WITH 1 STEEL 1"� MIN. WASHER, TO STRUCTURAL A36 STEEL MEMBERS, 4 ANCHORS PER BASE PLATE, ONE IN EACH CORNER "� CARBON STEEL WEDGE -BOLT CONCRETE ANCHOR WITH 1 "� MIN. WASHER, 2Y" 2 CONCRETE EMBEDMENT & 6" MIN EDGE DISTANCE, 4 ANCHORS PER BASE PLATE, ONE IN EACH CORNER 3 WOOD �"�� SAE GRADE 5 THREADED RODS WITH 3/a" MIN. WASHER AND LOCKING NUTS.. 4 ANCHORS PER BASE PLATE, ONE IN EACH CORNER Revision s ory # Description Revised b ECN# Date 0 Released o production N Perry 9 2/19/07 1 Added lb" Clearance CLEARANCE BELOW RAISED ROOF MOUNTED MECHANICAL UNITS 25 < 36 18 36 < 48 24 48 < 60 30 > 60 48 Brackets Perry 1367 5/8/08 2 Changed to steel zinc coating Perry 1505 11/17/08 e WSUBRF For 20 & 24 Duc erry 5 0 4 Added Support Plate N Perry 1845 2/9/10 CLEARANCE BELOW RAISED ROOF MOUNTED MECHANICAL UNITS 25 < 36 18 36 < 48 24 48 < 60 30 > 60 48