Loading...
HomeMy WebLinkAbout3800 Enterprise Way 16-320 Site planAA C000606 tNTERIOR ALTERATtON • CCCM Cq 3800 r� er rise a sul* e W JA _q C 0 Sanforlori'da,pay E� z� SEMINOLE COUNTY FLORIDA E W w� •SYMBOLS:Z3BUILDING KEY PLAN: PROJECT INFORMATION: DRAWING INDEX. DRAWING co CODES: SYMBOL DESCRIPTION AO.Q SITE LOCATION/ INDEX,/ INFORMATION FLORIDA BUILDING CODE BUILDING, 5th EDITION 2014 FLORIDA BUILDING CODE ACCESSIBILITY, 5th EDITION 2014 AO.1 LIFE SAFETY PLAN Iv FLORIDA BUILDING CODE ENERGY CONSERVATION, 5th EDITION 2014 NORTH ARROW A1.1 DEMOLITION PLAN &NOTES ..-._...-_..._._............._�.......--...-.-...............,_-............-......... FLORIDA BUILDING CODE EXISTING BUILDING, 5th EDITION 2014 ri\FLOOR PLAN FLORIDA BUILDING CODE MECHANICAL, 5th EDITION 2014 A2.1 FLOOR PLAN, SCHEDULES & DETAILS "-' SC^M �r - DRAWING TITLE -- - -- ---- ---- -- - -- .. ------ -- -- - --- - -- - - --- - -_-.._ ------------------------------------------ -------- ----------- ------ ..._.. _. A2 2 � FLORIDA BUILDING CODE PLUMBING, 5th EDITION 2014 REFLECTED CEILING PLAN °.. ' ✓r !!'' /' ,r' r"'/ / , ! ' ,'';'',° '.""` r ` ,""" i' ''^W' 'y,. NATIONAL ELECTRICAL CODE N.F.P.A. 70, 2011 EDITION r , ! ! .'`,f°" '°' ,+ , + ° 1 ;,' ✓" „ "' .+ BUILDING SECTION �J A3.1 DOOR FINISH SCHEDULES &DETAILS __...... _ ....... mmm__ . �.... t r" ✓`' ,, ,,,, // r;,- ; , "'" ,.' , ,, r / /" ' / 0 , �,... FLORIDA FIRE PREVENTION CODE, 5th EDITION 2014 / // / .�' ,�,.�'"� ,/� /` ,�" ", '�' /;, ;*"� `,�'"� '/' ,✓" %` �° ';� ',�° � � ,�"" ,�" „'� ,,�',✓/ � ? �' LIFE SAFETY CODE N.F.P. A. 101, 2012 EDITION M0.1 MECHANICAL PLAN " ✓ /'' �i /' f""" '' /✓' , l /^'' ° ° ✓'� � ", �" ° WALL SECTION �,;� '",✓ �' +! r,`° '�"°"` E0.1 ELECTRICAL PLAN OCCUPANCY: INTERIOR ELEVATION s B BUSINESS s -a ,. '�� �' , , � �' PROJECTTEAM: �' "° BUILDING AREA:� o f ✓ / / / j ✓' ✓ /' f' i /y ✓ / OFFICE ,r ✓ , " 14, ROOM NAME TOTAL BUILDING AREA 59,799 sq.ft. $ s .ft. PROPOSED LEASE SPACE 23,82 ARCHITECT: HARTER - ADAMS P.A.REVISION AREA AND SYMBOLOCCUPANTLOAD1370 GENE STREETCQ WINTER PARK, FL 32789(OFFICE) 100s.f. / OCCUPANTPHONE (407) 647-5767�/,3,397 s.f. /100 ..................................... 34 OCCUPANTS FAX: (407) 647-2062 DIMENSION TO FACE '... ,....- ,... %�/ <;%���//%; >/';// ' i, + ✓ ," /r , ,..' , A ADAMS "'°° ' '""'� WAREHOUSE 500s.f. / OCCUPANT /. "( ) CONT CTTOM ^/;, �+""✓,�"' �.�^ ,,✓''";,�`' .^"°° .,';' �✓"''" ,�''"'� , ,�,/ �✓�"" 0''"" '"*''" , ,!✓,,, ,�',,;' ,� /" f" �i ii��i;„// �i/-���i, i i ,� s +'' ,, '� !' r �,,,/ "/ '',,^ ^'"^”' �.. d✓ „' ,"*'� ✓° +y" ,""' ........................ Fes" ✓`' 20 431 s.f. /100........... .204 OCCUPANTS '����%% 2a lOb c FIRE EXTINGUISHER, 51b. ^� TOTAL= 238 OCCUPANTS CONTRACTOR: �I FIRST COMMERCIAL CONSTRUCTION GROUP LLC. /, . !;;i,;/,'" i %% r '"'' ✓ r 898 SHADICK DRIVE SUITE 300 ADJACENT OCCUPANCIES:p(D DOOR NUMBER ORANGE CITY FLORIDA, 32763 NORTH- "B., BUSINESS PHONE: (386 532-9000 ___._.....-_._..__,._._,.,.._...._................ _..M.,... ..M..._......,.,...,...,,.. CELL: (386) 804-2156 -0-' -+-' `�-4 A A SOUTH- N/A CONTACT: RICHE SEREMETA EXISTING 8" CMU/ STUD WALL W W c� woR TYPE OF CONSTRUCTION: _...... �--, TYPE VB. SPRINKLERED LEGALDEXISTING RATED PARTITION TO ROOF DECKNON COMBUSTIBLE__._�_.-���__� �.w_..,,..._......,._.�.�_._......................__,.......................,,,,,.,,,,�-.. �--� SCALE: 1"=30'—D" STRUCTURAL DESIGN CRITERIA:- PARCEL I.D.: 16-19-30-5Ac-0000-0570 �-.-- -�- PROPosED DEMOLITION BASIC WIND SPEED ............ 145 mph PART OF LOT 57 DESC AS BEG 400 FT W & 47 FT S OF NE COR OF Use coefficients from Chapter 16 F.B.C. SE %4 RUN E 182.95 FT CURVE SELY 235.08 FT S 434.53 FT W 332.50 PROPOSED RATED PARTITION TO ROOF DECK FTTO PT S BEG N TO BEG ........ ..................._w...................,_...,......�....,._.__�-...-...._..._.�.�....._.....-....-.......... IMPORTANCE FACTOR ......... 1 EXPOSURE ........ B ST JO PT S HS PROJECT SUMMARY:PB COMPONENTS AND CLADDING MAXIMUM DESIGN WIND 1 PG 114 PROPOSED METAL STUD PARTITIONS TO PRESSURE 48 A.F.F. (including doors and windows) ...... +32.8 psf, -43.9 psf THE SCOPE OF WORK INDICATED ON THESE DRAWINGS IS AN INTERIOR ALTERATION TO A SPACE IN AN EXISTING SINGLE STORY MASONRY BUILDING. THE FOUNDATION DESIGN BASED ON ALLOWABLE SOIL BEARING VICINITY MAP: PROPOSED METAL STUD PARTITIONS TO OCCUPANCY AND USE SHALL REMAIN GROUP "S-2" STORAGE W/ BUSINESS. PROJECT SHALL CONSIST OF SOME MIMIMAL DEMOLITION AND NEW PARTITIONS AS PRESSURE OF 2000 psf. CEILING NOTED ON PLANS. ELECTRICAL SCOPE SHALL CONSIST OF ADDING NEW LIGHT FIXTURES AND DUPLEX RECEPTACLES AS REQUIRED. PLUMBING SHALL CONSIST �" OF ADDING (1) ADA RESTROOM. HVAC SCOPE SHALL CONSIST OF ADDING A 1.5 TON SPLIT SYSTEM FOR NEW OFFICES.., ` TOTAL AREA ..................23,828 s.f.��,, N0. EXITS REQUIRED: 2 � ��xa'��� Q X01 � �N � �' REVIEWED FOR CO F'LIANCE 2NO. EXITS PROVIDED: 6 _ �EXAMI EFS DISTANCE TO EXIT REQ D. 250 - - DA1 f ff ;� � +t ^rc � i n�,^,��. " �r' I$�M1y„ r i ^ro�"1 „;. �d,,, i � r i, 0 EXIT PROVIDED: 73 —0 �� � � ;' � � , � �,,� � ��?��� ��4 , , �� � � � w JOB N O. MAX. DISTANCE T �, � �.�;, ��� � � „���s � � �,,� � � ��,, 'D6VISo® ;��ift +� +� kw '*»a*.�Iut � 7 � �I „.. G a,� ro lC x �r�'�ti ,�',°'� ��"�'�x,�„ ,a, F,. yp�,� k ^� t a '�. � ''� �.� �� �u v ,^�,„, 4b �`� � 1�G�y � �, a '. ��, i�lc "� <;��V,'�'�c Hi 'IIV .......---�--_"_ ._.o.:.-----'-- ��, ti�.�,.> °���, :� �������� -.. TRUEn To BEA � � soos N0. STORIES: ,iia ;u '�+.� ss ;w�1s> ,..,1 >Y 'C.}a,.2 R a' �'' rM a "` ,��^v,:^i, E x x� p� 3� 'as 't y `""u�", �k ... CONS 1 1�.,.,,, ��,y,^ w.�'.��1��?;«� ;• .�r:�� WC"~;a ,�L1HDRhl.��. FIG RK AND NOT AS � RMIT !.. S C WITH TVIt �NC3 OR SET i'FC)C�EE ALTER D A T E TE, CANCEL, I_IChrl� �ITYTr�VI(7lA C�THETECHNICAL SIC7NS VENT �,�:� ,,,,.�. .,. PRE 01/18/2016 . c '^�„`•,t .�.. v�; k,S r, a `�. !-6'af7S. ",: f, �u jii/ rl,: ra f,,,., v „ n�wM�.' r°":.;,�M, did^ `,,. .+::,: G.�R RIVIMIT »�, ,. .,, ,.., r u��r x.,, �fl+ W „�,,, N, �,,, ., ., 9, AN ECS EXTINGUISHER , �, .,. �.,."., +,, . >, �,, .,, � „ �.�,, IDE r� ANC r -1 - PLANS, A FEET OF FLOOR AREA. TRAVEL DISTANCE TO AN �.,�., < �. �., , �� p . , � ����.,r� « ���, �, � , ,r . , " .^�,� As � ,,,,u AFT. R HAVING A MINIMUM RATING OF 2A-10B—C FOR EVERY 3000 SQUARE �i► PROVIDE FIRE EXTINGUISHERS ,', ,��,,�? � �„.I�,:"` .,, �� NOR.�HALL f=ROM THERE S �>�, � �' ��^� ����„� ,* �,,."�•. � � �,�,�. �� +,� �� �t �,�„",���� GOf?E,.�, FFICIAL PLAN FIRE MARSHALL TO MEET LOCAL CODro.>..„^u.�,,�,��,��,���' ��� iH6�suiLo No�ERRO E s H E E T MOUNT AT 33 A.F.F. INSTALLED IN APPROPRIATE LOCATIONS AS DIRECTED BY tiaF, µ ��„ � �, � �;. � , , � �� � � SHALL NOT EXCEED 75 FEET. M O Y2 Q A C,oRR1EOcVIOLg oNS OF TH�s cop REI+INicTRI N Vim C CTIU INCLUDED IN THIS PERMIT. ORDINANCE 90 10 AND IS NOT i SIGNS: NOT INCLUDED. ALL SIGNAGE MUST COMPLY WITH HAPTER 31.5, A0.0 SPRINKLER MODIFICATIONS: FIRE PROTECTION DRAWINGS SHALL BE DONE UNDER A SEPERATE PERMIT. �,�,�v 0.� <sF➢�k `"i '�� r�`� �^:. ""�F y.T, '4, y^u�'� � fi; SR + ^r ,a�r�r �i'} ;. �� „, y�,";: �*ab ��W3' afi�•�j �'�% r^ �` ,�5^v w x � 1� �w'�r LEGEND EXISTING CMU/ STUD WALL PROPOSED DEMOLITION AA C000606 C. REPAIR ANY DAMAGE TO WALLS THAT ARE TO REMAIN. D. DEMOLITION OF MECHANICAL, ELECTRICAL AND PLUMBING ITEMS SHALL BE INDICATED ON THE DRAWINGS. E. WHERE EXISTING WALL -MOUNTED DEVICES, FIXTURES OR OTHER ITEMS OCCUR ON WALLS SCHEDULED TO RECEIVE NEW FINISHES, THESE SHALL BE REMOVED AND STORED BY THE CONTRACTOR AND REINSTALLED AFTER THE NEW FINISHES ARE COMPLETE. F. SPECIFIC DEMOLITION 15 NOT INDICATED IN AREAS WHERE IT MAY BE NECESSARY TO DEMOLISH ALL OR A PORTION OF: AN EXISTING BUILDING COMPONENT TO GAIN ACCESS TO AREAS FOR EXTENSION OR TIE-IN TO BUILDING SYSTEMS, OR WHICH MAY BE REQUIRED TO INSTALL NEW CONSTRUCTION, DEMOLITION FOR THESE PURPOSED SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER AND THESE AREAS SHALL BE RETURNED TO THE ORIGINAL CONDITION PROPR TO BEGINNING CONSTRUCTION. G. ALL ITEMS REMOVED BY DEMOLITION OPERATIONS SHALL BE THE PROPERTY OF THE CONTRACTOR UNLESS SPECIFICALLY INDICATED ON THESE DRAWINGS OR IDENTIFIED BY THE OWNER TO REMAIN OR BE RELOCATED. REMOVAL OF THESE ITEMS DEMOLISHED IS THE RESPONSIBILITY OF: THE CONTRACTOR. H. THE OWNER WILL IDENTIFY SPECIFIC ITEMS TO BE DEMOLISHED AND TURNED OVER FOR HIS USE. THESE IDENTIFIED ITEMS ARE TO BE REMOVED BY THE CONTRACTOR AND PROTECTING ITEM FROM DAMAGES DELIVERED TO A LOCATION AS DIRECTED BY THE OWNER. I. CONTRACTOR SHALL IDENTIFY ANY STRUCTURAL ELEMENTS TO BE DEMOLISHED AND PROVIDE TEMPORARY SHORING, BRACING OR SUPPORT REQUIRED TO ASSURE STRUCTURAL STABILITY OF ALL ELEMENTS REMAINING UNTIL NEW STRUCTURAL SUPPORT 16 COMPLETED. 3o 21916 DEMOLITION PLAN �ALr.��j '4- R E V I S 1 0 J 0 B N O. 1 16006 D A T E 01/18/2016 S H E E T A1.1 3 0 F 8 411 � ADJACENT TENANT/ NOT PART cc _N /* cv c\j tc OF SCOPE C\2 ... ..... ..... .......... . ... ..... .. PT4 JYL X rf X" Zn P4 44 IL ..............'Z_�m 0 � P-4 0 SCOPE OF LUORK -7 � DEMOLITION GENERAL NOTES E AN �BUIrQ13N C.0 t ,,--CrMO PARTIAL OPENING C. REPAIR ANY DAMAGE TO WALLS THAT ARE TO REMAIN. D. DEMOLITION OF MECHANICAL, ELECTRICAL AND PLUMBING ITEMS SHALL BE INDICATED ON THE DRAWINGS. E. WHERE EXISTING WALL -MOUNTED DEVICES, FIXTURES OR OTHER ITEMS OCCUR ON WALLS SCHEDULED TO RECEIVE NEW FINISHES, THESE SHALL BE REMOVED AND STORED BY THE CONTRACTOR AND REINSTALLED AFTER THE NEW FINISHES ARE COMPLETE. F. SPECIFIC DEMOLITION 15 NOT INDICATED IN AREAS WHERE IT MAY BE NECESSARY TO DEMOLISH ALL OR A PORTION OF: AN EXISTING BUILDING COMPONENT TO GAIN ACCESS TO AREAS FOR EXTENSION OR TIE-IN TO BUILDING SYSTEMS, OR WHICH MAY BE REQUIRED TO INSTALL NEW CONSTRUCTION, DEMOLITION FOR THESE PURPOSED SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER AND THESE AREAS SHALL BE RETURNED TO THE ORIGINAL CONDITION PROPR TO BEGINNING CONSTRUCTION. G. ALL ITEMS REMOVED BY DEMOLITION OPERATIONS SHALL BE THE PROPERTY OF THE CONTRACTOR UNLESS SPECIFICALLY INDICATED ON THESE DRAWINGS OR IDENTIFIED BY THE OWNER TO REMAIN OR BE RELOCATED. REMOVAL OF THESE ITEMS DEMOLISHED IS THE RESPONSIBILITY OF: THE CONTRACTOR. H. THE OWNER WILL IDENTIFY SPECIFIC ITEMS TO BE DEMOLISHED AND TURNED OVER FOR HIS USE. THESE IDENTIFIED ITEMS ARE TO BE REMOVED BY THE CONTRACTOR AND PROTECTING ITEM FROM DAMAGES DELIVERED TO A LOCATION AS DIRECTED BY THE OWNER. I. CONTRACTOR SHALL IDENTIFY ANY STRUCTURAL ELEMENTS TO BE DEMOLISHED AND PROVIDE TEMPORARY SHORING, BRACING OR SUPPORT REQUIRED TO ASSURE STRUCTURAL STABILITY OF ALL ELEMENTS REMAINING UNTIL NEW STRUCTURAL SUPPORT 16 COMPLETED. 3o 21916 DEMOLITION PLAN �ALr.��j '4- R E V I S 1 0 J 0 B N O. 1 16006 D A T E 01/18/2016 S H E E T A1.1 3 0 F 8 � ADJACENT TENANT/ NOT PART _N OF SCOPE ... ..... ..... .......... . ... ..... .. Zn DEMOLITION GENERAL NOTES t ,,--CrMO PARTIAL OPENING .� IN EXISTING WALL FOR A. THIS SHEET INDICATES GENERALLY WHERE DEMOLITION OF NEW DOOR EXISTING CONSTRUCTION IS TO OCCUR, IT IS THE 'T1 RESPONSIBILITY OF: THE CONTRACTOR TO VERIFY THE ACTUAL 1:1-, CONDITION. THE DEMOLITION SHOWN ON THIS SHEET 15 NOT INTENDED TO LIMIT OR FULLY DEFINE THE SCOPE OF ITEMS TO BE DEMOLISHED NOR IS IT INTENDED TO REPRESENT ALL !77=1 EXISTING FEATURES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SURVEYING THE AREA OF DEMOLITION PRIOR TO THE PREPARATION OF: HIS BID TO OBTAIN CLARIFICATION FROM THE i� 1fP I ARCHITECT PRIOR TO CONTINUING DEMOLITION WHEN UNUSUAL REMOVE EXISTING DOOR l� W � CONDITIONS EXIST. AND FRAME -HOLD FOR POSSIBLE RELOCATION B. CONTRACTOR SHALL PATCH, CLEAN AND REPAIR ALL WORN OR DAMAGED SURFACES TO PREPARE FOR NEW CONSTRUCTION co AND/ OR NEW FINISHES AFTER DEMOLITION. DEMO EXISTING n C. REPAIR ANY DAMAGE TO WALLS THAT ARE TO REMAIN. D. DEMOLITION OF MECHANICAL, ELECTRICAL AND PLUMBING ITEMS SHALL BE INDICATED ON THE DRAWINGS. E. WHERE EXISTING WALL -MOUNTED DEVICES, FIXTURES OR OTHER ITEMS OCCUR ON WALLS SCHEDULED TO RECEIVE NEW FINISHES, THESE SHALL BE REMOVED AND STORED BY THE CONTRACTOR AND REINSTALLED AFTER THE NEW FINISHES ARE COMPLETE. F. SPECIFIC DEMOLITION 15 NOT INDICATED IN AREAS WHERE IT MAY BE NECESSARY TO DEMOLISH ALL OR A PORTION OF: AN EXISTING BUILDING COMPONENT TO GAIN ACCESS TO AREAS FOR EXTENSION OR TIE-IN TO BUILDING SYSTEMS, OR WHICH MAY BE REQUIRED TO INSTALL NEW CONSTRUCTION, DEMOLITION FOR THESE PURPOSED SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER AND THESE AREAS SHALL BE RETURNED TO THE ORIGINAL CONDITION PROPR TO BEGINNING CONSTRUCTION. G. ALL ITEMS REMOVED BY DEMOLITION OPERATIONS SHALL BE THE PROPERTY OF THE CONTRACTOR UNLESS SPECIFICALLY INDICATED ON THESE DRAWINGS OR IDENTIFIED BY THE OWNER TO REMAIN OR BE RELOCATED. REMOVAL OF THESE ITEMS DEMOLISHED IS THE RESPONSIBILITY OF: THE CONTRACTOR. H. THE OWNER WILL IDENTIFY SPECIFIC ITEMS TO BE DEMOLISHED AND TURNED OVER FOR HIS USE. THESE IDENTIFIED ITEMS ARE TO BE REMOVED BY THE CONTRACTOR AND PROTECTING ITEM FROM DAMAGES DELIVERED TO A LOCATION AS DIRECTED BY THE OWNER. I. CONTRACTOR SHALL IDENTIFY ANY STRUCTURAL ELEMENTS TO BE DEMOLISHED AND PROVIDE TEMPORARY SHORING, BRACING OR SUPPORT REQUIRED TO ASSURE STRUCTURAL STABILITY OF ALL ELEMENTS REMAINING UNTIL NEW STRUCTURAL SUPPORT 16 COMPLETED. 3o 21916 DEMOLITION PLAN �ALr.��j '4- R E V I S 1 0 J 0 B N O. 1 16006 D A T E 01/18/2016 S H E E T A1.1 3 0 F 8 I AA C000606 co rl- c\j d CQ Ix BUILDING U' Q1.TNQ KEY PLAN wow A L 0 N.T.B. t:AI* I IM U I ILI IT LEGEND SINK EXISTING W-1-01111 1a), FOUNTAIN EXHAUST PAN 2& lob r- FIRE EXTINGUISHER, 51b. O DOOR NUMBERO .... ... . .... . ...... ..... Exisilm CMU/ STUD PARTITION C:) 25 GA, METAL STUD 7 NEW CLOSET PARTITIONS TO ROOF PECK TOIL T TOILET OFFICE ABOVE ......... . 3-%', 25 GA. METAL STUD PARTITIONS TO CEILM ........... ADJACENT TENANT/ NOT PART Or SCOPE 0 z 45 -F 77777 C) NEW cn cn W Z O FLOOR N r AL R E V I S 1 0 J 0 B N 0. 16006 D A T E 01/18/2016 1 S H E E T A2.1 4 0 F 8 LEGEND: EXHAUST FAN SUPPLY AIR REGISTER RETURN AIR REGISTER LLLLLLLL 2'X 4' LAY -IN FLUORESCENT LLLLLLLL LIGHT FIXTURS f " y ✓, ''� ADJACENT TENANT/ NOT PART OF SCOPE NOTE: THIS CEILING PLAN REFLECTS CONDITIONS AFTER ALL LIGHTING FIXTURES AND HVAC REGISTERS HAVE BEEN INSTALLED/ RELOCATED. ,u...... REFLECTED CEILING PLAN SCALE: 1/4' ■ l' -V' � Z, y A �� - AA C000606 � a • 1�co co co co cO w a w� Q aw w w �cc O cc w 4W 0 � a o w w � O cc R E V I S 1 0 5 J 0 B N 0. 16006 D A T E 01/18/2016 S H E E T A2.2 5 0 F 8 DOOR SCHEDULE N0. TYP E SIZE DESCRIP. FRAME HARDWARE NOTES DISPOSAL(RECESSBD) c: el - cit 0I. FINISH ON INTERIOR WALLS 4 ALL LOCKSETS SHALL BE p w CLG SHALL BE MINIMUM w 'Do Lu LEVER HANDLE SCWLAGE w x� � Ww W . a �a COMPLY WITH NFPA 101: a v� 'LEVON' SERIES 'A' 10.2-20M EDITION lu 4 C 2. HARDWARE FINISH u x BRUSHED CHROME BACKING FOR ALL WALL o 3. HINGES WAGER OR EQUAL ALL PAINT, CARPET AND FLOORING COLORS TO BE U4. DOOR LOCKS SHALL NOT REQUIRE USE OF KEY TOOL SELECTED BY OWNER. _j �u } OR SPECIAL KNOWLEDGE t0 NEW OFFICES • • 0 • • LI 10'-m' NEW NEW CLOSET 1 w • • OPERA I E FROM EGRESS SIDE • • • lm' -0' NEW SHOWROOM • • • • • 10'-1' EXISTING 1 B 3'-0' 1-0' 1-g4' 01010191 • 1 • • • • • EXISTING 2 A 3'-0' 6-8' 1-46' • • • • 1 NEW 3 A 3'-0' 6-8' 1-46' • • • • NEW 4 A 3'-0' 6-8' I-4boo 1 • • • • • RELOCATED 5 A 3'-1' 6-8' 1-46' • • 01 • EXISTING 6 A Pr. 3'-0' 1-1' 1-46' • • • 10 1 NEW 'I A V-0' 6-8' 1-%- • • • • NEW 8 A Pr. 3'-0' 6-8' 1-%' • • • • NEW a A B DOOR TYPES NTS O ,, FINISH SCHEDULE ROOM FLOOR BASE WALL CLG HT. NOTES DISPOSAL(RECESSBD) c: el - cit FINISH ON INTERIOR WALLS 4 p w CLG SHALL BE MINIMUM w Lu CLASS 'C' AND SHALL w x� � Ww . a �a COMPLY WITH NFPA 101: a v� 10.2-20M EDITION lu PROVIDE PLYWOOD BACKING FOR ALL WALL MTD FIXTURES ALL PAINT, CARPET AND FLOORING COLORS TO BE SELECTED BY OWNER. _j C.4O NEW OFFICES • • • • • 10'-m' NEW NEW CLOSET 1 • • • • • lm' -0' NEW SHOWROOM • • • • • 10'-1' EXISTING NEW TOILET • 01010191 1 10'41' NEW ACCESSORIES SCHEDULE NO. DESCRIPTION O MIRROR O GRAB BAR, 36' O TOILET PAPER HOLDER (DOUBLE) O GRAB BAR - 42' O SOAP DISPENSER O PAPER TOWEL DISP t DISPOSAL(RECESSBD) 30' X 48' CLEAR FLOOR SPACE POSITIONED FOR FORWARD APPROACH PIPE INSULATION (IF EXPOSED) PLUMBING FIXTURES WATER HEATER (Insts-Hot) WH. �+u� «RTE -3, 1.5 GPM, 3kW, 120 VOLTS WATER CLOSET WC. AMERICAN STANDARD 'CADET" ADA 16-1/2"H ELONGATED, 1b GPF, MOD. 0 2998.012 LAVATORY LV. AMERICAN STANDARD 'LUCERNE', WALL HUNG ADA W/ 4' CENTERS, MOD. " 0355.012 NOTE: ONLY NEW PLUMBING FIXTURES ARE LISTED. ISOMETRIC NOTE 0 ISOMETRIC PROVIDED TO CLARIFY PIPE ROUTING ONLY. DRAWINGS ARE DIAGRAMMATIC AND EXACT FIXTURE LOCATIONS, CONNECTIONS, FITTINGS AND MINOR PIPING OF SETS ARE NOT INDICATED AND SHALL BE SUBJECT TO FIELD INSTALLATION AND CODE REQUIREMENTS. NEW I . .Pvft AA 0000606 11 �� _ -- -- MIN yy 1'-4" 1-3 1- EQUIPMETED NT �-+ r I NEW � 6 BOUNDARY OR 1 LAY. •-� 42' s �.---i�g �"J -12 �O FACE Or - 3 F , I. N fw,w �, 3' 4444-- - --- 3 ® ? _-- PANELING .� O INSTALLED TO '' ,4 f I-V N �„ 61 _ 19 \ CONGEAL .-'"✓-� N r r �� EQUIPMENT _ _ *--- - (LINE OF KNEE - INST -NOT 2,_8, 4'-0' IN m SPACE - INSULATED PIPE _._. 8' M1P►CLEARANCE) — 6' MAX �LL �,� � KNEE CLEARANCE TOE CLEARANCE SEE PLANS SEE PLANS t1' MIN TO EXISTING 9 PLAN VIEW SECTION VIEW , SANITARY RISER o EXISTING FIXTURES •� �' 5 ADA TOILET ELEVATIONS WASTE RISER DIAGRAM VINs AS SCREENED SCALE: SCALE: N.T.S. p w � � d cc EXT. t ROOF DECK HOUSE GONG. FLOOR SLAB ROOF DECK CONCRETE FLOOR SLAB CONC. FLOOR SLAB � EXTERIOR WALL 2 INTERIOR WALL 3 INTERIOR WALL (EXISTINCs) 1. TOP AND BOTTOM RUNNERS 2. R-11 FIBERGLASS INSULATION (EXISTING) 3-1/2' GYP. BD. WALLS, 5/8' AT FIRE RATED ASSEMBLIES 4. 2-1/2' WIDE GALV. (U.ON.) METAL STUDS TO CEILING. MIN. 24' O.G., MAX GAUGE PER CHART BELOW, (25 GA. MINIMUM) 25 GA Il' -0' MAX UNBRACED 25 GA. PARTITION NGT. 20 GA. 14'-0' MAX. UNBRACED 20 GA. PARTITION NGT. 18 GA. ll' -0' MAX. UNBRACED 18 GA. PARTITION NGT. 16 GA. 20'-0' MAX. LNBRACED 16 GA. PARTITION NGT. 5. CONCRETE WALL (EXISTING) 6. SUSPENDED ACOUSTICAL CEILING TILES 1. SOUND ATTENUATION INSULATION (OPTIONAL) FOR INTERIOR PARTITIONS STUDS ARE FASTENED TO TOP AND BOTTOM TRACK WITH 1 010 TEK SCREW EACH SIDE OF EACH STUD. BOTTOM TRACK IS FASTENED TO FLOOR WITH PAF AT 24 ' AND TOP TRACK IS BRACED TO STRUCTURE ABOVE IF AND AS REQUIRED TO RESIST AT LEAST 5 PSF. 1/2' COLD WATER SUPPLY INTERIOR WALL TO ELECTRICAL CONNECTION ISOLATION VALVE INSTANT TANKLESS ELECTRIC WATER HEATER. SURFACE MOUNT TO WALL IN UNDER COUNTER SPACE FLOOR AN 21 7-016 1/2' HOT WATER TO FIXTURE INSTA-FLOW WATER HEATER DETAIL SCALE: 1/4' ■ 1'-0' ,I- zA-/40 R E V I S 1 0 J 0 B N 0. 16006 DA T E 01/18/2016 S H E E T A3.1 6 0 F 8 n. c: el - cit p w � w W w x� � Ww . a �a a v� 11 �� _ -- -- MIN yy 1'-4" 1-3 1- EQUIPMETED NT �-+ r I NEW � 6 BOUNDARY OR 1 LAY. •-� 42' s �.---i�g �"J -12 �O FACE Or - 3 F , I. N fw,w �, 3' 4444-- - --- 3 ® ? _-- PANELING .� O INSTALLED TO '' ,4 f I-V N �„ 61 _ 19 \ CONGEAL .-'"✓-� N r r �� EQUIPMENT _ _ *--- - (LINE OF KNEE - INST -NOT 2,_8, 4'-0' IN m SPACE - INSULATED PIPE _._. 8' M1P►CLEARANCE) — 6' MAX �LL �,� � KNEE CLEARANCE TOE CLEARANCE SEE PLANS SEE PLANS t1' MIN TO EXISTING 9 PLAN VIEW SECTION VIEW , SANITARY RISER o EXISTING FIXTURES •� �' 5 ADA TOILET ELEVATIONS WASTE RISER DIAGRAM VINs AS SCREENED SCALE: SCALE: N.T.S. p w � � d cc EXT. t ROOF DECK HOUSE GONG. FLOOR SLAB ROOF DECK CONCRETE FLOOR SLAB CONC. FLOOR SLAB � EXTERIOR WALL 2 INTERIOR WALL 3 INTERIOR WALL (EXISTINCs) 1. TOP AND BOTTOM RUNNERS 2. R-11 FIBERGLASS INSULATION (EXISTING) 3-1/2' GYP. BD. WALLS, 5/8' AT FIRE RATED ASSEMBLIES 4. 2-1/2' WIDE GALV. (U.ON.) METAL STUDS TO CEILING. MIN. 24' O.G., MAX GAUGE PER CHART BELOW, (25 GA. MINIMUM) 25 GA Il' -0' MAX UNBRACED 25 GA. PARTITION NGT. 20 GA. 14'-0' MAX. UNBRACED 20 GA. PARTITION NGT. 18 GA. ll' -0' MAX. UNBRACED 18 GA. PARTITION NGT. 16 GA. 20'-0' MAX. LNBRACED 16 GA. PARTITION NGT. 5. CONCRETE WALL (EXISTING) 6. SUSPENDED ACOUSTICAL CEILING TILES 1. SOUND ATTENUATION INSULATION (OPTIONAL) FOR INTERIOR PARTITIONS STUDS ARE FASTENED TO TOP AND BOTTOM TRACK WITH 1 010 TEK SCREW EACH SIDE OF EACH STUD. BOTTOM TRACK IS FASTENED TO FLOOR WITH PAF AT 24 ' AND TOP TRACK IS BRACED TO STRUCTURE ABOVE IF AND AS REQUIRED TO RESIST AT LEAST 5 PSF. 1/2' COLD WATER SUPPLY INTERIOR WALL TO ELECTRICAL CONNECTION ISOLATION VALVE INSTANT TANKLESS ELECTRIC WATER HEATER. SURFACE MOUNT TO WALL IN UNDER COUNTER SPACE FLOOR AN 21 7-016 1/2' HOT WATER TO FIXTURE INSTA-FLOW WATER HEATER DETAIL SCALE: 1/4' ■ 1'-0' ,I- zA-/40 R E V I S 1 0 J 0 B N 0. 16006 DA T E 01/18/2016 S H E E T A3.1 6 0 F 8 GENERAL NOTES ALL SIZES ARE IN INCHES UNLESS OTHERWISE NOTED. ALL DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. THE FIRST DIMENSION INDICATED IS THE DIMENSION SHOWN. ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS AND TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED WHERE REQUIRED WITHOUT ANY REDUCTION IN THE CROSS-SECTIONAL AREA OF THE AFFECTED DUCT. ALL EQUIPMENT AND DUCTWORK SHALL BE SUPPORTED ACCORDING TO SMACNA STANDARDS. PROVIDE ADDITIONAL SUPPORT AS REQUIRED TO PROVIDE A VIBRATION -FREE RIGID INSULATION. SUPPLY, RETURN AND FRESH AIR DUCTWORK SHALL BE FIBERGLASS DUCTWORK LINED WITH ANTI -MICROBIAL INSULATION (EQUAL TO "SUPERDUCT") MIN. R-6 INSULATION TO COMPLY WITH FLORIDA ENERGY EFFICIENCY CODE (2014 ED.). ALL FIBERGLASS DUCT AND DUCT WRAP SHALL BE SEALED WITH GLASS FAB AND MASTIC. FLEXIBLE DUCT CONNECTORS SHALL NOT EXCEED 10' IN LENGTH. ALL SQUARE ELBOWS SHALL INCLUDE FACTORY -FABRICATED SINGLE THICKNESS TURNING VANES. ALL SUPPLY DIFFUSERS SHALL BE INSULATED FROM THE CEILING GRID. INSULATE DIFFUSER BACK AND NECK WITH R-6 BATT INSULATION. SEAL WITH GLASS FAB AND MASTIC. CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC. BUILD FIBERGLASS PLENUM BOX ABOVE ALL RETURN AIR GRILLES. DUCT INTO CENTER OF BOX. MOUNT THERMOSTATS AT 4'-4" A.F.F. CONTRACTOR SHALL PROVIDE AND INSTALL ENGRAVED PLASTIC NAME PLATED FOR ALL FANS AND EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. THE NAME PLATES SHALL INDICATE THE ROOM SERVED, ITEM NUMBER AND SHALL BE LOCATED BOTH ON THE EQUIPMENT AND WHERE POWER SHUT-OFF IS. PROVIDE TEST AND BALANCE FOR ALL AIR CONDITIONING SYSTEMS. TEST AND BALANCE SHALL BE IN ACCORDANCE WITH AABC STANDARDS. TEST AND BALANCE REPORT SHALL BE SUBMITTED TO OWNER. COORDINATE WITH ELECTRICAL CONTRACTOR TO PROVIDE 120V SERVICE OUTLET WITHIN 6' OF ALL EQUIPMENT. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA MECHANICAL CODE (2014 ED.), 2014 FLORIDA ENERGY CODE, AND MOST RECENT EDITIONS OF 2012 NFPA 90A, 2012 NFPA 101 W/ FLA. AMENDMENTS, ASHRAE, SMACNA, NEC AND THE LOCAL AUTHORITY HAVING JURISDICTION. WRAP SUCTION REFRIGERANT PIPING WITH MIN. 1/2" THICK CELLULAR RUBBER EQUAL TO ARMSTRONG ARMAFLEX. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND SERVICE CLEARANCE REQUIREMENTS. COORDINATE WITH CONTRACTOR TO UNDERCUT ALL RESTROOM, STORAGE ROOM AND JANITOR CLOSET DOORS BY 3/4" FOR AIR TRANSFER. AIR DISTRIBUTION PLAN IS DIAGRAMMATIC ONLY AND IS PROVIDED FOR LAYOUT PURPOSES ONLY. CONTRACTOR IS RESPONSIBLE FOR COORDINATING DIFFUSER AND GRILLE LOCATIONS WITH LIGHTING PLAN AND CEILING GRID. HVAC HEX NOTES: 1ENEW SUSPENDED AIR HANDLER UNIT. TNEW CONDENSING UNIT ON ROOF DECK (NOT SHOWN) ISI EXISTING EXHAUST AIR LOUVER -TIE NEW PAN TO EXISTING DUCT. IALL -1/2- SAG /2" SAG 1 /2" OOT OF )RT NG. AIR BALANCE SCHEDULE SPACE TYPE AREA N0. PEOPLE FRESH AIR REQ'D DESIGN FRESH AIR (20 CFM/PERS) CFM OFFICES 135 6 120 120 FRESH AIR REQUIREMENTS BASED ON ASHREA 62.1-2004. UNDERCUT BATHROOM DOORS 1" FOR AIR RETURN ENTIRE RETURN AIR SYSTEM SHALL BE DUCTED EXCEPT FOR BATHROOMS AIR DISTRIBUTION SCHEDULE A LOUVERED CEILING DIFFUSER. 24 x24 FACE SIZE. NECK SIZE AS INDICATED ON DRAWINGS. ALUMINUM, WHITE FINISH, OPPOSED BLADE DAMPER. MS TMDC-AA OR EQUIVALENT. B EGGCRATE RETURN GRILLE. 24 x 24 FACE WITH 22 x 22 NECK. ALUMINUM GRID WITH ALUMINUM BORDER, STANDARD CORE, WHITE FINISH, OPPOSED BLADE DAMPER. TITUS 50F OR EQUIVALENT. AIR CONDITIONING SCHEDULE AHU-1: NEW SUSP, HORIZONTAL AIR HANDLER, 18,000 BTUH TONAL CAPACITY. 5.0 kW ELECTRIC STRIP HEATER, 600 CFM SUPPLY AIR, CARRIER MODEL FA4CNFO18 OR EQUIVALENT SUPPLY WITH ON/OFF/AUTO DIGITAL T -STAT. WEIGHT: 150# MOCP 60A OUTSIDE AIR: 12'10 CFM SW --1: NEW OUTDOOR CONDENSING UNIT. 18,000 BTUH TOTAL CAPACITY, 13 SEER. MOCP 40A CARRIER MODEL 24ABR3018 OR EQUIVALENT. FAN SCHEDULE EF 2 : NEW CEILING EXHAUST FAN. 80 CFM 0 0.125" S.P. 2.5 SONES, 850 RPM, 115V POWER. INCLUDE WALL CAP AND TIME DELAY SWITCH. BROAN MODEL "HD 80" OR APPROVED EQUAL. INTERLOCK FAN OPERATION WITH LIGHTS. H . V. A. C. LEGEND TERMINALS ® SUPPLY REGISTER RETURN REGISTER ® NEW EXHAUST FAN NEW FLEX DUCT aNEW 24/7 DIGITAL-PROGRAMABLE THERMOSTAT AHU-1 0 FLEXIBLE SUPPORTS DETAIL NOT TO SCALE RUN REFRIGERANT PIPING TO CONDENSING UNIT. SIZE LINES AS PER MANUFACTURERS --- 3/8' HANGER RODS SECURE RECOMMENDATIONS. TO STRUCTURE ABOVE. CONDENSING UNIT AA 0000606 PROVIDE ANY ACCESSORIES VIBRATION ISOLATOR - MASON REQUIRED FOR VERTICAL HEIGHT. TYPE 'HD' FLEX T FLEX CONNECTION CONNECTION ROUTE CONDENSATE TO DRYWELL. INSULATE s^ AIR HANDLER � • PIPE 4 TRAP WITH 4' nn ARAFLEX WHERE THE PIPE IS RUN WITHIN THE BUILDING VIBRATION ISOLATION �? AND WHERE CONDENSATION PAD (TYP. OF 4 0 MAY CAUSE DAMAGE. CORNERS) o PROVIDE ACCESSIBLE W Q FILTER RACK UNI -STRUT 4 3/8' ALL THREAD ROD.- P -CRAP 17 � o SECURE WITH FLAT WASHERS 4 WING NUTS. (SEE DETAIL) l;C Q'' 0 _ CONDENSATE DRAIN PAN - 3' j PREFABRICATEDMl` _A'L H HIGH X 3' LARGER THAN UNIT._ SUPPORT (TYPICAL PAN SHALL BE 18 GA. GALV. AS MFR'D BY 'AES ✓) u: SHEET. CROSSED BRACED AS INDUSTRIES, INC. BEAMS SHALL BE SOLDERED. MODEL N0. AES -1. PROVIDE 18GA. 2" WIDE SHEET METAL FLOAT CONTROL SHUT-OFF FULL SIZE ACCESS PANEL \� TIE -DOWN STRAP. CONNECT TO UNIT W w10 VALVE (SHUT UNIT OFF IN 3/8" BOLT NUT AND WASHER AND CURB USING 5/16" SELF -DRILLING E OVERFLOW CONDITIONS. (TYP. EACH CURB) ��> SCREWS WITH WASHERS (TYP. OF -•� `�T'-I w w 4 LOCATIONS) NOTES: W w 1.) SECURE CONDENSING UNIT TO ROOF PER LOCAL HURRICANE CODE REQUIREMENTS. a 2. COORDINATE INSTALLATION WITH BUILDING OWNER AND COMPLY WITH ALL REQUIREMENTS NECESSARY TO MAINTAIN WARRANTY. AR HANDLER N STALLAT ON DETAIL -CONDENSING UNIT SUPPPORT DETAIL � � N.T.S. NOT TO SCALE SPIN—IN FITTING HANGER (TYP.) t7 FLEX DUCT O.B. DAMPER ~ NSULATE COLLAR AND TOP RIGID DUCT .— SIDE OF DIFFUSER WITH R-6 INSULATION W/ ALUM. JACKET. T—BAR FRAME —\ r _ + SEAL ALL JOINTS WITH MASTIC. CEILING CEILING DIFFUSER DETAIL NOT TO SCALE MECHANICAL SCOPE OF WORK SHALL BE TO ADD (1) NEW SUSPENDED AIR HANDLER AND (1) NEW ROOF TOP CONDENSING UNIT WITH FLEX DUCTS & REGISTERS AS REQUIRED TO ACOMODATE (3) NEW OFFICES ADDED TA CDAM7 DI AAI kAIC' JAUPAI 97AIIIMAGAIT M0 CVICTIAIP! CDAM' CI-IAI I 17GA1AN WITH kin PWAAICF (D�IECHANICAL PLAN LE: , - �-Z' Y, z/. R E V I S 1 0 J O B N O. 16006 D A T E 01/18/2016 S H E E T 6 0 F 8 N � W ct O O Q � � ~ 4-; � ct Q 1—I � R E V I S 1 0 J O B N O. 16006 D A T E 01/18/2016 S H E E T 6 0 F 8 ELECTRICAL SPECIFICATIONS SECTION 16010 - ELECTRICAL GENERAL PROVISIONS 1. ALL WORK AND EQUIPMENT SHALL BE IN COMPLIANCE WITH THE FOLLOWING CODES AND STANDARDS: A. NFPA-101, LIFE SAFETY CODE. B. NFPA-70 (2011), NATIONAL ELECTRICAL CODE C. FLORIDA MECHANICAL CODE (2014) D. FLORIDA BUILDING CODE (2014). E. AMERICANS WITH DISABILITIES ACT . 2. ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECT, EXCEPT WHERE SPECIFICALLY NOTED ON THE PLANS TO BE RECONNECTED OR REUSED. 3. ALL SYSTEMS SHALL BE TESTED FOR PERFORMANCE VERIFICATION IN THE PRESENCE OF THE OWNER AT COMPLETION OF PROJECT. 4. VISIT THE JOBSITE PRIOR TO BID AN EXAMINE THE EXISTING COND111ONS INCLUDE ALL MATERIAL AND LABOR FOR A COMPLETE INSTALLATION, SEC11ON 16050 - BASIC MATERIALS AND METHODS 1 ELECTRICAL CONNECTIONS TO EQUIPMENT A PROVIDE POWER CIRCUIT WIRING FOR ALL EQUIPMENT REQUIRING ELECTRICAL POWER AND CONNECT COMPLETE UNLESS OTHERWISE INDICATED IN THE CONTRACT DOCUMENTS. B MOTOR HORSEPOWER AND EQUIPMENT SIZES SHOWN AND/OR SPECIFIED ARE ESTIMATED AND SIZE OF WIRE, CONDUIT AND CIRCUIT PROTECTION DEVICES ARE BASED ON SAID ESTIMATE. ASCERTAIN THE ACTUAL HORSEPOWER AND CURRENT REQUIREMENTS, OF THE MOTORS AND EQUIPMENT TO BE INSTALLED, PRIOR TO BEGINNING INSTALLA11ONS OF FEEDERS FOR SAME. IF THE ACTUAL REQUIREMENTS ARE DIFFERENT, NOTIFY THE ENGINEER TO OBTAIN CLARIFICATION. C BALANCING ELECTRICAL LOAD: EXERCISE CARE IN CONNECTING THE VARIOUS ELECTRICAL LOADS TO THE PANELS IN ORDER TO ARRIVE AT A REASONABLE BALANCE BETWEEN LOADS IN EACH PHASE AT EACH PANEL MAKE TESTS AND ADJUST LOADS AT EACH PANEL TO RESULT IN A REASONABLY BALANCED LOAD CONDITION, SATISFACTORY TO THE UTILITY COMPANY, ENGINEER, OWNER AND INSPECTION AGENCIES. 2 WIRE AND CABLE - 600 VOLT A CONDUCTORS: 98% CONDUCTIVITY, SOFT DRAWN COPPER. B INSULATION: HEAT AND MOISTURE RESISTANT, THHN/THWN 600 -VOLT RATING C..USE STRANDED CONDUCTOR ON ALL WIRING #6 AWG AND LARGER. ALL OTHER WIRING MAY BE SOLID. System No. W -L-1001 June 15, 2005 F Ratings - 1, 2, 3 and 4 Hr (See Items 2 and 3) T Ratings - 0, 1, 2, 3, and 4 Hr (See Item 3) L Rating At Ambient - less than 1 CFM/sq ft L Rating At 400 F - less than 1 CFM/sq ft SECTION A -A 3 WIRING DEVICES A PROVIDE SWITCHES AND RECEPTACLES AS MANUFACTURED BY HUBBELL, PASS & SEYMOUR, LEVITON, ARROW -HART OR GENERAL ELECTRIC. B DUPLEX RECEPTACLES: 20 AMP, 120 VOLT, HEAVY DUTY, COMMERCIAL GRADE, GROUNDING TYPE MEETING THE REQUIREMENTS OF FED. SPEC. WC -596, NEMA WD -1, AND UL -498. C LIGHT SWITCHES: 20 AMP, 120/277 VOLT, HEAVY DUTY, COMMERCIAL GRADE, QUIET TYPE MEETING THE REQUIREMENTS OF FED. SPEC. WS -896 AND NEMA WD -1. D USE SMOOTH STYLE, 0.10" THICK, PHENOLIC OR UREA PLASTIC PLATES. MATCH COLOR OF PLATE WITH COLOR OF DEVICE. PROVIDE PLATES FOR ALL SWITCHES, RECEPTACLES, TELEPHONES AND ALL UNUSED JUNCTION BOXES. E ALL DEVICES SHALL BE DECOR STYLE, WHITE. 4 GENERAL REQUIREMENTS A USE GOOD WORKMANSHIP IN THE (INSTALLATION OF ALL ELECTRICAL MATERIALS AND EQUIPMENT. INSTALL EQUIPMENT LEVEL, PLUMB AND TRUE WITH THE STRUCTURE AND OTHER EQUIPMENT. FIRMLY SECURE ALL MATERIALS IN PLACE AND ADEQUATELY SUPPORTED AND PERMANENT. MATERIALS EMBEDDED IN CONCRETE OR MASONRY OR OTHERWISE PART OF THE STRUCTURE ARE CONSIDERED SUFFIC-IENTLY SUPPORTED. USE HARDWARE AND ACCESSORY FITTINGS OF A TYPE DESIGNED, INTENDED AND APPROPRIATE FOR THE USE AND COMPLEMENT THE ITEMS WITH WHICH THEY ARE USED. 5 MINIMUM SIZES A CONDUIT: 1/2" FOR SWITCH LEGS AND BRANCH CIRCUITS. 3/4 -FOR ALL HOMERUNS UNLESS OTHERWISE INDICATED. B WIRE: #12 AWG FOR ALL POWER AND LIGHTING CIRCUITS. SIGNAL AND CONTROL WIRING MAY BE SMALLER, AS INDICATED. #10 AWG FOR ALL HOMERUNS UNLESS OTHERWISE INDICATED 6 WIRING METHODS A INSTALL ALL WIRING IN CONDUIT OR APPROVED RACEWAYS UNLESS OTHERWISE INDICATED. CONCEAL THE CONDUIT AND OUTLET INSTALLATION IN WALLS, ABOVE FINISHED CEILINGS, UNDERGROUND OR UNDER FLOOR AS SHOWN ON DRAWINGS. CONDUITS MAY BE RUN EXPOSED ON WALLS AND CEILINGS OF ELECTRICAL ROOMS, MECHANICAL ROOMS, AND/OR OTHER LOCATIONS AS INDICATED. B UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS, PROVIDE CONDUIT IN ACCORDANCE WITH THE 1. Wall Assembly - The 1, 2, 3 or 4 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs (max 2 h fire rated assemblies) or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC with nom 2 by 4 in. (51 by 102 mm) lumber end plates and cross braces. Steel studs to be min 3-5/8 in. (92 mm) wide by 1-3/8 in. (35 mm) deep channels spaced max 24 in. (610 mm) OC. B. Gypsum Board* - Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft. (122 cm) wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 26 in. (660 mm). 2. Through -Penetrant - One metallic pipe, conduit or tubing installed either concentrically or eccentrically within the firestop system. The annular space between pipe, conduit or tubing and periphery of opening shall be min of 0 in / (0 mm). (point contact) to max 2 in. (51 mm) Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe - Nom 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 24 in. (610 mm) diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in (305 mm) diam (or smaller) or Class 50 (or heavier) ductile iron pressure pipe. C. Conduit - Nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 4 in (102 mm) diam (or smaller) steel electrical metallic tubing D. Copper Tubing - Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing E. Copper Pipe - Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. F. Through Penetrating Product* - Flexible Metal Piping The following types of steel flexible metal gas piping may be usedl: 1. Nom 2 in. (51 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. OMEGA FLEX INC 2. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. GASTITE, DIV OF TITEFLEX 3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. WARD MFG INC 3. Fill, Void or Cavity Material* -Caulk or Sealant - Min 5/8. , 1-1/4,1-7/8 and 2-1/2 in. (16, 32, 48 and 64 mm) thickness of caulk for 1, 2, 3 and 4 hr rated assemblies, respectively, applied within annulus, flush with both surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulk applied to gypsum board/penetrant interface at point contact location on both slides of wall. The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below: Max Pipe or Conduit Diam In mm F RATING Hr T RATING Hr 1 25 1 or 2 0+, 1 or 2 125 3or4 3or4 4 102 1 or 2 0 6 152 3 or 4 0 12 305 1 or 2 0 +When copper pipe is used, T Rating is 0 h. 3M COMPANY - CP 25WB+ or FB -3000 WT. *Bearing the UL Classification Mark FOLLOWING: RIGID METAL CONDUIT (RMC): ANYWHERE EXCEPT CORROSIVE ENVIRONMENTS INTERMEDIATE METAL (IMC): ANYWHERE EXCEPT CORROSIVE ENVIRONMENTS THINWALL METAL (EMT): ANYWHERE EXCEPT AS FOLLOWS: UNDERGROUND. IN SLABS ON GRADE. CORROSIVE ENVIRONMENTS. SCHEDULE 40 AND 80 PVC: UNDERGROUND ONLY, CORROSIVE ENVIRONMENTS: USE RMC OR IMC COATED IN ACCORDANCE WITH NEC 300-6 MC CABLE IS GENERALLY ACCEPTED WHERE ALLOWABLE BY LOCAL CODE AND APROVED BY OWNER. C USE FLEXIBLE STEEL CONDUIT WITH GROUND WIRE FOR FINAL CONNECTION TO MOTORS AND LIGHT FIXTURES. USE SEALTITE IN DAMP OR CORROSIVE ATMOSPHERES. D DO NOT PULL CONDUCTORS INTO CONDUITS UNTIL ALL WORK WHICH MAY CAUSE DAMAGE TO THE WIRES IS COMPLETED. INSTALL WIRE AND CABLES SO AS NOT TO DAMAGE THE INSULATION OR CABLE SHEATH. PULL ALL CONDUCTORS TO BE INSTALLED IN A RACEWAY TOGETHER. TRAIN AND GUIDE WIRES INTO THE RACEWAY USING A PULLING COMPOUND OR LUBRICANT WHEN NECESSARY. PROVIDE A MEANS OF COMMUNICATION BETWEEN THE PULLING AND GUIDING POINTS TO FACILITATE INSTALLATION AND TO HELP PREVENT DAMAGE. USE A PULLING MEANS THAT WILL NOT DAMAGE THE RACEWAY. E KEEP CONDUCTOR SPLICES TO A MINIMUM. PROVIDE SPLICES AND TAPS WITH AT LEAST THE EQUIVALENT MECHANICAL STRENGTH AND INSULATION AS THE CONDUCTORS. PROVIDE SPLICE AND TAP DEVICES OF THE PROPER SIZE AND TYPE FOR THE USE AND COMPATIBLE WITH THE CONDUCTOR MATERIAL. ALL SPLICES SHALL BE MADE IN JUNCTION BOXES OR TERMINAL CABINETS. NO SPLICES SHALL BE PERMITTED IN CONDUIT(S). 7. EQUIPMENT MOUNTING A INSTALL EQUIPMENT ON CEILING, WALL OR FLOOR AS INDICATED OR AS APPROPRIATE. PROVIDE FASTENERS OR SUPPORTS SUFFICIENT IN SIZE AND QUANTITY TO SUBSTANTIALLY SECURE THE EQUIPMENT IN PLACE TO THE BUILDING STRUCTURE OR STRUCTURAL ELEMENT. B INSTALL THE EQUIPMENT PLUMB, TRUE AS INTENDED AND SECURE. WHEN SEVERAL ITEMS OF EQUIPMENT ARE WALL MOUNTED IN THE SAME AREA, LINE THEM UP VERTICALLY AND HORIZONTALLY ALONG WITH ANY ASSOCIATED RACEWAYS. 8. SLEEVES A WHERE CONDUITS PASS THROUGH SLEEVES IN EXTERIOR WALLS, CAULK THE ANNULAR SPACE WITH OAKUM AND FILL INSIDE AND OUT WITH A NON - HARDENING, WATERPROOF SEALANT FINISHED OFF FLUSH WITH BOTH FACES OF THE WALL. SECTION 16500 - LIGHTING 1. U.L. LABELS MUST APPEAR ON ALL LIGHTING FIXTURES. FLEXIBLE CONDUIT TAILS, UP TO SIX FEET IN LENGTH, MAY BE USED BETWEEN JUNCTION BOXES AND RECESSED LIGHTING FIXTURES. OUTLET BOXES MAY SERVE UP TO FOUR SEPARATELY RECESSED FIXTURES. BALLASTS SHALL BE ELECTRONIC HIGH-POWER FACTOR CBM LABELED. 2. PROVIDE PROPER TRIM PER REFLECTED CEILING PLAN OR ACTUAL CEILING INSTALLED. 3 PROVIDE LAMPS IN ALL FIXTURES SECTION 16195 -ELECTRICAL IDENTIFICATION DESCRIPTION TYPE 4. EXIT SIGNS, EMERGENCY BATTERY PACKS AND EMERGENCY INVERTERS SHALL BE 1. PROVIDE EACH BRANCH CIRCUIT PANEL WITH A DIRECTORY INDICATING CONNECTED TO LOCAL CIRCUITS AHEAD OF SWITCHING. LOADS SERVED. THE PANEL SCHEDULES SHOWN ON THE PLANS DO NOT SECTION 16740 - COMMUNICATIONS SYSTEM CONTAIN ADEQUATE INFORMATION TO BE COPIED AND USED AS PANEL 1. PROVIDE 3/4"X2'X2' HIGH PLYWOOD BACKBOARDS IN LOCATION SHOWN ON DRAWINGS. A PAINT WITH FIREPROOF GREY PAINT. PROVIDE #6 INSULATED COPPER GROUND WIRE DIRECTORIES. LABEL EACH CIRCUIT WITH ACTUAL ROOM NUMBERS OR FROM BACKBOARD TO SERVICE GROUND. ROOM NAMES SERVED, SUCH AS "RECPT 109, 110, 111". 2. EACH OUTLET SHALL BE PROVIDED WITH (1) 3/4"C STUBBED TO CEILING SPACE. 2. USE ENGRAVED PLAQUES FOR LABELING LARGE EQUIPMENT. 3. PROVIDE (1) 1-1/4"C. FROM TENANT TTB TO BUILDING TTB. 3. LABEL EACH POWER JUNCTION BOX WITH AN INDELIBLE MARKER 16720 - FIRE ALARM AND DETEC11ON SYSTEM INDICATING THE CIRCUIT NUMBERS CONTAINED WITHIN. EMERGENCY BATTERY UNIT -HIGH INTENSITY LIGHTOLIER 1. EXTEND EXISTING FIRE ALARM SYSTEM PER THE NATIONAL FIRE SECTION 16400 - SERVICE AND DISTRIBUTION ALARM CODE (NFPA 72) AND A.D.A. 1. PANEL BOARDS SHALL HAVE LOCKING COVERS AND USE BOLT -ON CIRCUIT 2. ALL WIRING SHALL BE IN RACEWAY. LED 3. PROVIDE BATTERY BACKUP PER NFPA. PROVIDE CALCULATIONS BREAKERS. DESIGN BASIS IS SQUARE -D QOB OR EQUAL. PROVIDE SHORT AND SIGNED & SEALED PERMIT DRAWINGS BY THIRD PARTY. CIRCUIT RATINGS AS INDICATED ON THE PLANS. 4. MOUNT PULL STATIONS 48" AFF; HORN/STROBES 80" AFF. 2. DISCONNECTS FOR U.L LISTED EQUIPMENT SHALL BE MATCHED TO THE DESIGN IS BASED ON 75CANDELA STROBES. NAMEPLATE REQUIREMENTS OF THE EQUIPMENT AS SUBMITTED BY THE 5. PROVIDE ALL ADDITIONAL HARDWARE FOR CONTROL PANEL V REQUIRED TO OPERATE ALL NOTIFICATION AND CONTROL APPLIANCES MECHANICAL CONTRACTOR. IT IS UNDERSTOOD THAT MANY KINDS OF 6. INSTALLER SHALL BE "E.F." LICENSED, SHALL OBTAIN PERMIT, DESIGN CHANGES, VALUE ENGINEERING CHANGES, AND BRAND NAME AND SHALL PROVIDE CERTIFICATION PER NFPA OF COMPLIANCE AT SHOPPING OCCUR BETWEEN THE 11ME THESE PLANS ARE MADE AND THE JOB COMPLETION. TIME OF FINAL EQUIPMENT PURCHASE. VERIFY FINAL EQUIPMENT RATINGS 7. ALL DEVICES TO BE U.L LISTED TO FUNCTION WITH EXISTING WITH SUBMITTALS. CONTROL PANEL Ww B. ALL WORK SHALL BE PROVIDED BY THE OWNER'S SERVICE WARRANTY CONTRACTOR. 3. IN FUSED SWITCHES, PROVIDE DUAL -ELEMENT FUSES SIZED PER EQUIPMENT NAMEPLATES. 4. TOGGLE TYPE SWITCHES MAY BE USED AS DISCONNECTS WHERE SHOWN ON THE PLANS. PROVIDE PROVISIONS FOR LOCK -OUT. SECTION 16450 - GROUNDING 1. PROVIDE GROUND CONDUTORS IN ALL CONDUITS. 2. PROVIDE GROUNDING BUSHINGS FOR FEEDER CONDUITS. 3. SERVICE GROUND RESISTANCE SHALL BE MEASURED WITHOUT DEPENDING ON WATER PIPING SYSTEM AND SHALL BE 25 OHMS OR LESS, IF GREATER THAN 25 OHMS, DRIVE ADD11IONAL GROUND RODS TO OBTAIN REQUIRED RESISTANCE. 4' 60JAIRE SOX PROVIDE FIRE -RATED PUTTY IN BOXES IN FIRE -RATED WALLS. 24" MINIMUM PLAN VIEW i 24' MIN. N RIGID OR EMT CONDUIT CONNECT GROUNDING LUGS OF RECEPTACLES #12 WIRE SEE ARCHITECTURAL PLANS FOR WALL CONSTRUCTION BACK TO BACK ELECTRICAL OUTLETS DETAIL N.T.S. NOTE: BACK-TO-BACK OUTLET BOXES ON RATED WALLS AND PARTY WALLS SHALL BE SEPERATED BY A MINIUM 24" 2 WERP)�P? LE: I�4 I'-®' LIGHTING FIXTURE SCHEDULE DESCRIPTION TYPE LAMPS DESCRIP11ON MANUFACTURER / CATALOG NUMBER SEE NOTE NO TYPE A 3 F32TB 2X4 LAY -IN FLUORESCENT WITH ACRYLIC LENSE LIGHTOLIER MOUNTED ABOVE COUNTER XP2GVA332S0HPFU 1,2 EM 2 5.4 WATT TUNGSTEN EMERGENCY BATTERY UNIT -HIGH INTENSITY LIGHTOLIER WPG=WEATHERPROOF GROUND FAULT E5 -W 1 X WALL OUTLET BOX AND SPECIAL RECEPTACLE LED UNIVERSAL EXIT SIGN LIGHTOLIER LTNURW 1 � O V DATA /PHONE � 1 NOTES: 1. UTHONIA AND DAYBRITE SHALL BE CONSIDERED EQUAL 2. ALL FLUORESCENTS TO HAVE ELECTRONIC BALLASTS. 3. ONLY NEW LIGHT FIXTURES SHOWN ON SCHEDULE -ALL OTHERS TO REMAIN. W ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION WALL OUTLET BOX AND 20 AMP DUPLEX RECEPTACLE 2' x 4' LAY -IN FLUORESCENT LIGHT FIXTURE nn $ WALL OUTLET BOX AND 20 AMP DUPLEX RECEPTACLE { RECESSED LIGHT FIXTURE CQ cz cc MOUNTED ABOVE COUNTER 7 EMERGENCY LIGHTS (BATTERY PACKS) oFa 4 WALL OUTLET BOX AND 20 AMP GFI RECEPTACLE WPG=WEATHERPROOF GROUND FAULT 0-i WALL OUTLET BOX AND FIXTURE ® WALL OUTLET BOX AND SPECIAL RECEPTACLE ® CEILING OUTLET BOX AND EXIT LIGHT FIXTURE SHADING INDICATES FACE � O V DATA /PHONE � WALL OUTLET BOX AND SINGLE POLE SWITCH W w 20 AMP �--� BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN Ww WALL � LIGHTING PLAN / y.._rt. 1. CONNECT EXIT AND EMERGENCY LIGHTS TO LOCAL CIRCUITS AHEAD OF SWITCHING. 2. ALL EXISTING LIGHTS & ELECTRICAL ARE SHOWN AS SCREENED LINES AND WA SHALL REMAIN. 3. ALL NEW LIGHTS & DUPLEX RECEPTACLE OUTLETS TO TIE TO EMPTY CIRCUIT IN EXISTING PANEL AA C000606 R E V I S 1 0 J O B N O. 16006 D A T E 01/18/2016 S H E E T E0. 1 8 0 F 8 . nn � co I - U1 CQ cz cc W W <Io CQ x� � O Q a� NIS � O I � � W w � k Ww �a c� R E V I S 1 0 J O B N O. 16006 D A T E 01/18/2016 S H E E T E0. 1 8 0 F 8 Q� � C�2 U1 � W ^ � O r� W NIS � O O R E V I S 1 0 J O B N O. 16006 D A T E 01/18/2016 S H E E T E0. 1 8 0 F 8 x. �Y SANFORD FIRE DEPAR ENS' THESE PLANS ARE REVIEW AND JA _q C 0CONDITIONALLY ACCEPTE 0000606. PERMIT. AN ISSUED PERMIT S DEEMED WORK AND NOT AS U OER R TY WITH Wd TO VIOLATE, CANCEL, ALTER Ft SET ASIDE ANY OF THESE PROVII SS Cf INTERIOR ALTERATIONTHE TECHNICAL CODES N ISSUANCE OF A PERMIT MIT PRO NF T FIRE PREVENTION a` THEREAFTER REOUI IN CORRECTION OF ERRORS NTH PLANS, CONSTRUCTION O OTHER 3800 Enterpri*se Way,sul*tet1t0 VIOLATIONS OF THE GORE.4i a Sanfordori* ax� � W P4 Review y'; T / F. FLORIDA F W n SEMINOLE COUNTY, � Ho Mrd Fre ept. W ., •DRAWING SYMBOLS,BUILDING KEY PLAN. PROJECT INFORMATION. DRAWING INDEX. CODES: SYMBOL DESCRIPTION AO.0 SITE LOCATION/ INDEX/ INFORMATION FLORIDA BUILDING CODE BUILDING, 5th EDITION 2014 FLORIDA BUILDING CODE ACCESSIBILITY, 5th EDITION 2014 AO.1 LIFE SAFETY PLAN NORTH ARROW FLORIDA BUILDING CODE ENERGY CONSERVATION, 5th EDITION 2014 A1.1 DEMOLITION PLAN & NOTES " ~~ "'~ "~ _,,,._..." FLORIDA BUILDING CODE EXISTING BUILDING, 5th EDITION 2014 , FLOOR PLAN FLORIDA BUILDING CODE MECHANICAL, 5th EDITION 2014 A2.1 FLOOR PLAN, SCHEDULES &DETAILS A— SCALE: 1/16"-, DRAWING TITLE 0 NG, 5th EDITION 2014 A2.2 REFLECTED CEILING PLAN ,,,,,,,,, ,,,,,,,,, .__ ._._..,_....�....�....__.....__._..._....._.............._..... ..._......_"„_.._.._._. � / FLORIDA BUILDING CODE PLUMBING, /,`^' ,r""� ,r r d1 "^''�, ''r �,,f �""""� '"�” �' / ✓f^.' ,✓'" " r* �. „""""' i . "^,' " `"' ' °! � �,:'` ,/` , ' �„� ,ar^"��,""„�' " 1 ..', r' TICAL CODE N.F.P.A. 70 2011 EDITION �'" ✓' ,"""" NATIONAL ELECTRICAL '(TC�7 BUILDING SEC11ON A3.1 DOOR/ FINISH SCHEDULES &DETAILS _ _....._,. FLORIDA FIRE PREVENTION CODE, 5th EDITION 2014 ,r' °�" r�" /' ✓"r "'` �'"""r� � /" /'' '� r""" ,�` .:�"" "' r "/ ,� ,✓""�",°' ✓,,^""° „� "" " " ""'" ` I fir".' , / /'"""' r" / / ° ,° %"" "°"" f ' / r, ✓' r ! , " // LIFE SAFETY CODE N.F.P.A. 101, 2012 EDITION Mo.1 MECHANICAL PLAN + r/ � '' !'''' "° ". /" :+'rr''✓ ,/' "I"" ,r' �` , "�"" �:, `,✓s "" ""' """ ^"''�`'" '/�'"" ^' �,"" r'°"r"�✓'" .�^""" � `'"'",r' % ",'' f� +✓'`j: ✓ e."`°, �.�r ,✓" '✓" f „i / ,° ME SECTION r ^' WALL ",,,r �,: �, r, "^^"° ,.�' /' ",,," „r� /^°"�,:' "/^" ,,+'' �,^" / ,,'" i' ,�^^" r^ ,,'"" ^� /'� :,�' ,,/"" /°^ .r^ "�„^' ,✓,+ ,r" e" ^'"'� r /" ,%f / r"` :"''`,J� '�„ ,✓' .r"" // ............... ... ........,.,................,......_.._�»........................,....__...................»»,..�,»...»..,....»............._" ra ,� "/" ✓"° "" ,,✓' �:"," ,:"' / ,,""'" /` ,,/ ,✓""✓"'^r .�,,/",�' !r/r" „✓"^."" ^ ,"r A ","'''' ,''` r ", "," ✓" �,,✓"` '� ! s"'F",r,"✓' ^,,:'° ,/ r' ,r° °;"` ,✓ / "' . Eo.1 d '' ° ;/ s / / ,,.✓" OCCUPANCY. ELECTRICAL PLAN " f ' „ OR ELEVATION r INTERIOR r S-3 B BUSINESS r� BUILDING AREA: PROJECTTEAM. ✓ "'` r e / ✓ / ✓"% �% s r ✓ ""^ r r" OFFICE /;r"' ,,✓" X �," 799 s .ft. TOTAL BUILDING AREA 59, ROOM NAME " Ix '"i s .ft. ,^ / 23 828 ,��' EXISTING LEASE SPACE r^' EX STI ` r` ARCHITECT: 7� " ,/ _ REVISION AREA AND SYMBOL -i-� " """" "' ,".� �' r"s HA ER ADAMS P.A. �- /,°'/511 STREET C� r J/ / " r ✓' /''""° ,' ' ✓ f r " r"'" ✓:.'' OCCUPANT LOAD 1370 GENE NN / ✓°'", % !✓ ,'` ° r r f ;'' '/"": , f' " ' ✓ , :^" /;" WINTER PARK, FL 32789 ✓ / r r'",rf`" .f ^ ✓' " ,./, ✓° .. OCCUPANT E - r . (OFFICE) 100s f / PHONE: (407) 647 5767 s TO FACE W r'' i r %.; % i /;/,;, r " F ✓................................... 34 OCCUPANTS FAX: 407 647-2062 DIMENSION 3,397 s.f. /100.. ( ) / i r ^ �i'� / i/i-;/, �i/ j � -�/�; / /',�/ ,✓"fir' , /r ' r'"` ^"^ ;,' � ,✓ .� ✓' .............. s �' r..�...........:...r_.. ....r .,/,,��, /� ; /�,,,, ,,;�,%;/i ,,,';% �' /, � "'"�,"/'' {,,, :,^"" ,,,�CONTACT: TOM ADAMScd 'i��/; r '" '' (WAREHOUSE) 500s.f. / OCCUPANT r ✓' ,'" �� �;/,., , %iii„i , � , /;-�j /icy ,� ,."'' ” r ,r"°""� , " " "." r � �r "r � � ,.+° / .........................204 OCCUPANTS / ✓' // // / , � i/, , , / ,� : 20 431 s. f. 100........... ;�%: , ,;,;/�,,; ,.:�� ;✓ s" "r""""�: /' ,�;" ,� TOTAL- 238 OCCUPANTS •�' � �" %' /, ,,/, ;�/ , /� ; „< ,� ", ,�" ° , �'� „� ,'' � ," � y;.. 2a 10b c FIRE EXTINGUISHER, 51b. / ' °/ / r"""" / r,�` ,' CONTRACTOR: ,�'" °, i// / ,,�,,,; i,/�;,,� ;,,,,,/,., ,."" ,� ,✓J,%'� `,�'� r "r ""`�"' � ,, FIRST COMMERCIAL CONSTRUCTION GROUP, LLC. �,✓ �„" rr � r" ^"" f �r" fi " / � �y °",� ✓ �'"° i; ,, /:� �i, �,"/, i ,;'%iii o �,"'" `" , r' """ ," ' '' ,:'" �s, r°"' 898 SHADICK DRIVE, SUITE 300 0 w b ^ „_ _f.r ” :, ' ADJACENT OCCUPANCIES. a ORANGE CITY FLORIDA, 32763 DOOR NUMBER NORTH- "B" BUSINESS PHONE: (386 532-9000 - ►� p CELL: (386) 804-2156 A A SOUTH- N/A CONTACT: RICHE SEREMETA EXISTING 8" CMU/ STUD WALL woR+c TYPE OF CONSTRUCTION: _.... E—+ o TYPE VB, SPRINKLERED LEGAL DEXISTING RATED PARTITION TO ROOF DECK �NON COMBUSTIBLE~ SCALE: 1"=,30'-O" C C PROPOSED DEMOLITION STRUCTURAL DESIGN CRITERIA: / PARCEL I.D.: 16-19-30-5AC-0000-0570____~_.w__� BASIC WIND SPEED ............ 145 mph PART OF LOT 57 DESC AS BEG 400 FT W & 47 FT S OF NE COR OF tJ Use coefficients from Chapter 16 F.B.C. SE %4 RUN E 182.95 FT CURVE SELY 235.08 FT S 434.53 FT W 332.50 PROPOSED RATED PARTITION TO ROOF DECK FTTO PT S BEG N TO BEG �u_._, ._...._�.�.�.. ............................... ,,,,..,....._.........ww........................,............... IMPORTANCE FACTOR ......... 1 EXPOSURE ........ B ST JO PT S PROJECT SUMMARY. COMPONENTS AND CLADDING MAXIMUM DESIGN WIND PB 1 S 114 HS PROPOSED METAL STUD PAR1111ONS TO PRESSURE Cisme.,. 48" A.F.F..,�...._~_�..�..__� (including doors and windows) ...... +32.8 psf, -43.9 psf THE SCOPE OF WORK INDICATED ON THESE DRAWINGS IS AN INTERIOR ALTERATION TO A SPACE IN AN EXISTING SINGLE STORY MASONRY BUILDING. THE FOUNDATION DESIGN BASED ON ALLOWABLE SOIL BEARING VICINITY MAP: PROPOSED METAL STUD PARTITIONS TO OCCUPANCY AND USE SHALL REMAIN GROUP "S-2" STORAGE W/ BUSINESS. PROJECT SHALL CONSIST OF SOME MIMIMAL DEMOLITION AND NEW PARTITIONS AS PRESSURE OF 2000 psf. CEILING NOTED ON PLANS. ELECTRICAL SCOPE SHALL CONSIST OF ADDING NEW LIGHT FIXTURES AND DUPLEX RECEPTACLES AS REQUIRED. PLUMBING SHALL CONSIST OF ADDING (1) ADA RESTROOM. HVAC SCOPE SHALL CONSIST OF ADDING A 1.5 TON SPLIT SYSTEM FOR NEW OFFICES... R E V I S I O IN offl, TOTAL AREA ..................23,828 s.f. rn N NO. EXITS REQUIRED: 2 Y y 2NO. EXITS PROVIDED: 6 MAX. DISTANCE TO EXIT REQ D: 250 � � � � � f �s �A b� $ � a �Y'ry� i.��l rt� ,�� `� ��. r�'k`a "�� � rLf ���"A" �`� d�R'�S L. �. '� yrs p� d „�ry J x M�^ E ? y 2 U . r, � �` � *•. �'�� Ili tips rf �f� �rr '�„ f �yk, r f ilin� , `wva : �"0 ,�''' S� d �� 1 ff =�1'�'i"; �„�! #f ,: �„ ,� �,,, .�' rl'x riri., ,wz; � t .£ " � . ` , a :.,� uL a1+ t� v'�r^v �^^, ,� i f '� "y. ,, �, aro t l i , i^ �^ e � 1 L "^,�,,,,y iu � � r MAX. DISTANCE TO EXIT PROVIDED: 73 0 g k, r fa''ar.,fs$'? '.. �" .a r :t {f u.4h r' s'"M'"'i.,,^�`u' ",, `°"r , "",',.:': p " +,�'� ^ �,: w.i , t8t..:ati ",7+ d E, JO B N O. >K }pi'�� �� t J ���:�"� � �'..,� ' syaC"d m�*w"f� "� ��'�s a y ,���bd r� . '" +°? y'^�°"^`w f`��, a� ��r a �%km,f i'� �;a; "� �� r . "��'�,.. `+ -_.�9 �/ �.:��; '""�^'�^,f ti C .. � 1 V oO6 i Mjy ,;, . ", Sy'�� ¢ : +��:~a^""4' h a WY'ny "* %t" rtir "." r ii, �� N0. STORIES: ................. 1 �� ��...; "�.;,. � ��'"�'�. " "� , � r�� r '�� 3 , � �' f�i 2s � li m ���, fy ,+w+ w �i � 'LS" i�?' m I/� � " � ��� f 3, � �i �t � d f , a &, t elk �14.,�' //' .w � "' �. � "�; �p ,..,;.. ,. ....,. 01/18/2016 . ,ter..'. "a; M. d';-aru� �i,'fr, ~;, e �. ��. ,.�„� �..i , .w��J„ ,� ��,sa,l, ` � f , v, ,h : f;r „,`✓. �+..,, :.a. k ,,.. c ,e.,:e�, .. .�,.: '�,1;i AV DISTANCE TO AN EXTINGUISHER,_.,..,. R HAVING A MINIMUM RATING OF 2A-10B—C FOR EVERY 3000 SQUARE FEET OF FLOOR AREA. TRAVEL PROVIDE FIRE EXTINGUISHES �:� , � ,�� ,, "!L'w i 1, a�+�r�'1 >�..'. *, .',�,,�i ia�r"'9u, d� f tlu�,�,r�v� �"*. C^',i�l '�fk� �' °� °1 y:,5�d,�t+u'�xY�,. FIRE MARSHALL TO MEET LOCAL CODES. ,,f T EXCEED 75 FEET. MOUNT AT 33 Y A.F.F. INSTALLED IN APPROPRIATE LOCATIONS AS DIRECTED BY �� "���.,,. .�� h��'�, ��,. _ ���.� ”^��t��,f Fc�. °°�, ���!k SHALL N0 2 ,;-�.` ca,!,i 1a�,"� ti ,I, (ay " ,..� i ��r ". rr,�1�1 s� , .rr ,,� u1.gw Jiy `M y ""�,�;.. �t ",,. r'.. ". "'add`"^:"a`.;, ✓'K rL »?; +trk524� ^d". lea°''"+,',:.I<<xs PERMIT. ,; ° s t . NOT INCLUDED IN THIS � xs "� � � � �� � � � �. � ��a SIGNS: NOT INCLUDED. ALL SIGNAGE MUST COMPLY WITH HAPTER 3�.5, ORDINANCE 90 10 AND IS �, ,� �� �.,,�.;ad, a, �, � *�� : ,� �1,�1>�,�;;x,s� ����;�, � �>��,��, ��� A0.0 SPRINKLER MODIFICATIONS: FIRE PROTECTION DRAWINGS SHALL BE DONE UNDER A SEPERATE PERMIT. 9 1 0 F 8 LEGEND EXISTING CMU/ STUD WALL AA C000606 PROPOSED DEMOLITION N O. 16006 ADJACENT TENANT/ NOT PART D A T E OF SCOPE S H E E T . . ... .... . ....... ..... xx 8 sag Zn CQ C\2 TOILET DEMOLITION GENERAL NOTES C\2 DEMO PARTIAL OPENING ct k it IN EXISTING WALL FOR A. THIS SHEET INDICATES GENERALLY WHERE DEMOLITION OF c> NEW DOOR EXISTING CONSTRUCTION IS TO OCCUR. IT 16 THE RESPONSIBILITY OF: THE CONTRACTOR TO VERIFY THE ACTUAL CONDITION. THE DEMOLITION SHOWN ON THIS SHEET 15 NOT P4 INTENDED TO LIMIT OR FULLY DEFINE THE SCOPE OF ITEMS TO r as 5S DEMOLISHED NOR IS IT INTENDED TO REPRESENT ALL EXISTING FEATURES. THE CONTRACTOR SHALL 5E RESPONSIBLE FOR SURVEYING THE AREA OF DEMOLITION MOR TO THE 4-o PREPARATION OF HIS 151P TO OBTAIN CLARIFICATION FROM THE REMOVE EXISTING DOOR ct ARCHITECT PRIOR TO CONTINUING DEMOLITION WHEN UNUSUAL AND FRAME -HOLD FOR YYL 51 S. CONTRACTOR SHALL PATCH, CLEAN AND REPAIR ALL WORN z cc OR DAMAGED SURFACES TO PREPARE FOR NEW CONSTRUCTION g AND/ OR NEW FINISHES AFTER DEMOLITION. DEMO EXISTING 9a /* z W L7— I P4 "8 ........................ acofor: or- uJow-7 E-4 P' BUILDING KEY PLAN PROPOSED DEMOLITION N O. 16006 ADJACENT TENANT/ NOT PART D A T E OF SCOPE S H E E T . . ... .... . ....... ..... 3 0 F 8 sag Zn CQ TOILET DEMOLITION GENERAL NOTES ''d DEMO PARTIAL OPENING ct k it IN EXISTING WALL FOR A. THIS SHEET INDICATES GENERALLY WHERE DEMOLITION OF c> NEW DOOR EXISTING CONSTRUCTION IS TO OCCUR. IT 16 THE RESPONSIBILITY OF: THE CONTRACTOR TO VERIFY THE ACTUAL CONDITION. THE DEMOLITION SHOWN ON THIS SHEET 15 NOT INTENDED TO LIMIT OR FULLY DEFINE THE SCOPE OF ITEMS TO 5S DEMOLISHED NOR IS IT INTENDED TO REPRESENT ALL EXISTING FEATURES. THE CONTRACTOR SHALL 5E RESPONSIBLE FOR SURVEYING THE AREA OF DEMOLITION MOR TO THE 4-o PREPARATION OF HIS 151P TO OBTAIN CLARIFICATION FROM THE REMOVE EXISTING DOOR ct ARCHITECT PRIOR TO CONTINUING DEMOLITION WHEN UNUSUAL AND FRAME -HOLD FOR CONDITIONS EXIST. POSSIBLE RELOCATION S. CONTRACTOR SHALL PATCH, CLEAN AND REPAIR ALL WORN cc OR DAMAGED SURFACES TO PREPARE FOR NEW CONSTRUCTION g AND/ OR NEW FINISHES AFTER DEMOLITION. DEMO EXISTING C. REPAIR ANY DAMAGE TO WALLS THAT ARE TO REMAIN. D. DEMOLITION OF MECHANICAL, ELECTRICAL AND PLUMBING ITEMS SHALL 5E INDICATED ON THE DRAWINGS. E. WHERE EXISTING WALL -MOUNTED DEVICES, FIXTURES OR OTHER ITEMS OCCUR ON WALLS SCHEDULED TO RECEIVE NEW FINISHES, THESE SHALL BE REMOVED AND STORED BY THE CONTRACTOR AND REINSTALLED AFTER THE NEW FINISHES ARE COMPLETE. F. SPECIFIC DEMOLITION 15 NOT INDICATED IN AREAS WHERE IT MAY M NECESSARY TO DEMOLISH ALL OR A PORTION ION OF AN EXISTING BUILDING COMPONENT TO GAIN ACCESS TO AREAS FOR EXTENSION OR TIE-IN TO 5UILDIWs SYSTEMS, OR WHICH MAY BE REQUIRED TO INSTALL NEW CONSTRUCTION, DEMOLITION FOR THESE PURPOSED SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER AND THESE AREAS SHALL BE RETURNED TO THE ORIGINAL CONDITION PROPR TO BEGINNING CONSTRUCTION. G. ALL ITEMS REMOVED BY DEMOLITION OPERATIONS SHALL BE THE PROPERTY OF THE CONTRACTOR UNLESS SPECIFICALLY INDICATED ON THESE DRAWINGS OR IDENTIFIED BY THE OWNER TO REMAIN OR BE RELOCATED. REMOVAL OF THESE ITEMS DEMOLISHED IS THE RESPONS151LITY OF THE CONTRACTOR. H. THE OWNER WILL IDENTIFY SPECIFIC ITEMS TO 5E DEMOLISHED AND TURNED OVER FOR HIS USE. THESE IDENTIFIED ITEMS ARE TO BE REMOVED BY THE CONTRACTOR AND PROTECTING ITEM FROM DAMAGES DELIVERED TO A LOCATION AS DIRECTED BY THE OWNER. 1, CONTRACTOR SHALL IDENTIFY ANY STRUCTURAL ELEMENTS TO BE DEMOLISHED AND PROVIDE TEMPORARY SHORING, 5RACIW_% OR SUPPORT REQUIRED TO ASSURE STRUCTURAL STABILITY OF ALL ELEMENTS REMAINING UNTIL NEW STRUCTURAL SUPPORT 18 COMPLETED. DEMOLITION PLAN SCALE= R E V I S 1 0 Q02/25/16 Owner Req d. Changes J 0 B N O. 16006 D A T E 01/18/2016 S H E E T A1.1 3 0 F 8 LEGEND: RE) EXHAUST FAN SUPPLY AIR REGISTER RETURN AIR REGISTER LLLLLLEL LLLLLL 2'X 4'LAY-IN FLUORESCENT LLLLLL: L LLLLLLI--JLL LIGHT FIXTURE ADJACENT TENANT/ NOT PART OF SCOPE CEILING: THIPLAN REFLECTS CONDITIONS AFTER ALL LIGHTING FIXTURES AND HVAC REGISTERS HAVE 555N INSTALLED/ RELOCATED. AA C000606 R E V I S 1 0 I A 02/25/16 Owner Reqd. Changes I J 0 B N O. 16006 D A T E 01/18/2016 S H E E T /OOX REFLECTED CEILING PLAN SCALE: 1/4'01'-0' A2.2 —�(; 1 O o �� C\2 CID c\j to c C\2 �w is P4 M O R E V I S 1 0 I A 02/25/16 Owner Reqd. Changes I J 0 B N O. 16006 D A T E 01/18/2016 S H E E T /OOX REFLECTED CEILING PLAN SCALE: 1/4'01'-0' A2.2 —�(; 1 O o �� C\2 n �w is M R E V I S 1 0 I A 02/25/16 Owner Reqd. Changes I J 0 B N O. 16006 D A T E 01/18/2016 S H E E T /OOX REFLECTED CEILING PLAN SCALE: 1/4'01'-0' A2.2 —�(; 1 DOOR SCHEDULE N0. TYP E SIZE DESCRIP. FRAME HARDWARE NOTES co �l2 P- C\2 �N O FINISH ON INTERIOR WALLS i o I. AI.L LOCKSETS SHALL BE x� CLO SHALL DE MINIMUM z� Q �, ca LEVER HANDLE SCHLAGE w� ao ba COMPLY WITH NFPA 01: pi O 'LEVON' SERIES 'A' F' 10.2-20M EDITION C uPROVIDE 2. HARDWARE FINISH PLYWOOD QED CHROME V lu U C 4 3. HINGES HAGER OR EQUAL Z 1 a -i '� } 4. DOOR LOCKS SHALL NOT BEMIRE USE OF KEY TOOL R FLOORING COLORS TO ®E p OR SPECIAL KNOWLEDGE TO NEW OFFICES p • It 0 • • 10'-0' NEW d5 • > OPERATE FROM EGRESS SIDE • • • 10'-0' NEW SHOWROOM 414 • 014 • • d I c 10'-0' EXISTING NEW TOILET • I I I to • • • 10'-0' M n 1 3'-0' 1-0' 1 -iia' • • • • • • EXISTING 2 A 3'-0' 6-8' 1-4i' • • • • NEW 3 A 3'-0' 6-8' 1 -*6' • • • • NEW 4 A V-0' 6-8' 1 -fib' • • • • 10 RELOCATED 5 A 3'-0' 6-8' 1 -fib' •• • • EXISTING 6 A Pr. V-0' 1-0' 1-4b' • • • • 1 NEW 1 A 3'-0' 6-6' 1-46' • • • • NEW 8 A Pr. V-0' 6-S' 1-4b' • • • • NEW a A B DOOR TYPES NTO FINISH SCHEDULE ROOM FLOOR BASE WALL CLG HT. NOTES co �l2 P- C\2 �N O FINISH ON INTERIOR WALLS i o a x� CLO SHALL DE MINIMUM z� �, ca CLASS 'C' AND 844ALL w� ao ba COMPLY WITH NFPA 01: pi O F' 10.2-20M EDITION uPROVIDE PLYWOOD SACKING FOR ALL WALL U U 4 MTD FIXTURES Z 1 ALL PAINT, CARPET AND a R FLOORING COLORS TO ®E p SELECTED 15Y OWNER NEW OFFICES • • • • • 10'-0' NEW NEW CLOSET • • • • • 10'-0' NEW SHOWROOM • • • • • 10'-0' EXISTING NEW TOILET • I I I to • • • 10'-0' NEW ACCESSORIES SCHEDULE NO. DESCRIPTION 0 MIRROR 0 GRAD BAR, 36' O TOILET PAPER HOLDER (D015LE) O GRA BAR - 42' O SOAP DISPENSER O PAPER TOWEL. DISP t DISPOSAL (fE:�SS>✓D) PLUMBING FIXTURES WATER I -EATER (Insta-Hot) WH. RHEEM "RTE -3, 1.5 GPM, 3kW, 120 VOLTS WATER CLOSET WC. AMERICAN STANDARD 'CADET' ADA 16-1/2"H ELONGATED, 1.6 GPF, MOD. * 2998.012 LAVATORY LV. AMERICAN STANDARD 'LUCERNE', WALL HUNG ADA W/ 4' CENTERS, MOD. " 0355.012 NOTE: ONLY NEW FLUM51NG FIXTURES ARE LISTED. ISOMETRIC NOTE a ISOMETRIC PROVIDED TO CLARIFY PIPE ROUTING ONLY. DRAWINGS ARE DIAGRAMMATIC AND EXACT FIXTURE LOCATIONS, CONNECTIONS, FITTINGS AND MINOR PIPING OF SETS ARE NOT INDICATED AND SHALL BE SUBJECT TO FIELD INSTALLATION AND CODE REQUIREMENTS. NEW AA 0000606 30' X 48' CLEAR PIPE INSULATION G FLOOR SPACE(IF EXPOSED) I I POSITIONED FOR � E- �' NEW . I FORWARDWG I 0 6 APPROACH - f -'.,. ,. 2" 3'-0" - - -- - - MIN 1-4 PERMITTED U I w --.., 1'-3'_- -- EQUIPMENT I� I 1 I NEW .--i I I � BOUNDARY OR ��� � � E �I LAV 12' 42' I' g ®� FACE OP'" w.. 11",� 0"PANELING' i N t�`- _. ........... - INSTALLED TO�- - Q m 23 19" \� CONCEALrL .'° I C� r EQUIPMENT m n +-\ -- . Q, Z (LINE OF KNEE - 2 -8' — -- 4'-0' IN s - ,� SPACE EARANCE) ,.w., INSTA-NOT 8 INSULATED PIPE -_--- EA b _>' .__-- CLEA MNC'.E TOE Cl AR 4M 3 F"el SEE PLANS SEE PLANS u' MIN TO EXISTING,. w •,-� ------- -- - - -- -- PLAN VIEW SECTION VIEW SANITARY RISER EXISTING FIXTURES SHOWN AS SCREENED ADA TOILET ELEVATIONS WASTE RISER DIAGRAM LINES 5 6 Q SCALE:SCALE: N.T.S. ►--, �° W w � EXT. ROOF DECK ROOF DECK HOUSE CONC. FLOOR SLA5 ROOF DECK 0 9 O _. CONCRETE FLOOR SLAB CONC. FLOOR SLAB � EXTERIOR WALL 2 INTERIOR WALL 3 INTERIOR WALL (EXISTING) 1. TOP AND BOTTOM RUNNERS 2. R-11 FIBERGLASS INSULATION (EXISTING) 3.1/2' GYP. 5D. WALLS, 5/8' AT FIRE RATED ASSEM5LIES 4. 2-V2' WIDE GALV. (U.ON.) METAL STUDS TO CEILING. MIN. 24' O.C., MAX GAUGE PER CHART 5ELOW, (25 GA. MINIMUM) 25 CSA Il' -0' MAX. L,NIBRACED 25 GA PARTITION NGT. 20 GA. 14'-0' MAX UNBRACED 20 GA. PARTITION NGT. 18 GA 1'I'-0' MAX. UV5RACED 18 GA. PARTITION NGT. 16 GA 20-0' MAX. U45RACED 16 GA PARTITION HGT. 5. CONCRETE WALL (EXISTING) 6. SUSPENDED ACOUSTICAL CEILING TILES 1. SOUND ATTENUATION INSULATION (OPTIONAL) FOR INTERIOR PARTITIONS STUDS ARE FASTENED TO TOP AND 50TTOM TRACK WITH 1 010 TEK SCREW EACH SIDE OF EACH STUD. 50TTOM TRACK IS FASTENED TO FLOOR WITH PAF AT 24 ' AND TOP TRACK IS 5RACED TO STRUCTURE A50VE IF AND AS REQUIRED TO RESIST AT LEAST 5 PSP. 1/2' COLD WATER SUPPLY 4 I NSTA-FLOC SCALE: 1/4' -1'-0' ISOLATION VALVE 1/2' HOT WATER TO FIXTURE HEATE INTERIOR WALL TO ELECTRICAL CONNECTION INSTANT TANKLESS ELECTRIC WATER HEATER. SURFACE MOUNT TO WALL IN UNDER COUNTER SPACE FLOG Ir �y 16 R E V I S 1 01 J O B N 0. 16006 D A T E 01/18/2016 S H E E T A3.1 6 0 F 8 co �l2 P- C\2 �N O o a x� d z� �, ca W N w� ao ba pi O 30' X 48' CLEAR PIPE INSULATION G FLOOR SPACE(IF EXPOSED) I I POSITIONED FOR � E- �' NEW . I FORWARDWG I 0 6 APPROACH - f -'.,. ,. 2" 3'-0" - - -- - - MIN 1-4 PERMITTED U I w --.., 1'-3'_- -- EQUIPMENT I� I 1 I NEW .--i I I � BOUNDARY OR ��� � � E �I LAV 12' 42' I' g ®� FACE OP'" w.. 11",� 0"PANELING' i N t�`- _. ........... - INSTALLED TO�- - Q m 23 19" \� CONCEALrL .'° I C� r EQUIPMENT m n +-\ -- . Q, Z (LINE OF KNEE - 2 -8' — -- 4'-0' IN s - ,� SPACE EARANCE) ,.w., INSTA-NOT 8 INSULATED PIPE -_--- EA b _>' .__-- CLEA MNC'.E TOE Cl AR 4M 3 F"el SEE PLANS SEE PLANS u' MIN TO EXISTING,. w •,-� ------- -- - - -- -- PLAN VIEW SECTION VIEW SANITARY RISER EXISTING FIXTURES SHOWN AS SCREENED ADA TOILET ELEVATIONS WASTE RISER DIAGRAM LINES 5 6 Q SCALE:SCALE: N.T.S. ►--, �° W w � EXT. ROOF DECK ROOF DECK HOUSE CONC. FLOOR SLA5 ROOF DECK 0 9 O _. CONCRETE FLOOR SLAB CONC. FLOOR SLAB � EXTERIOR WALL 2 INTERIOR WALL 3 INTERIOR WALL (EXISTING) 1. TOP AND BOTTOM RUNNERS 2. R-11 FIBERGLASS INSULATION (EXISTING) 3.1/2' GYP. 5D. WALLS, 5/8' AT FIRE RATED ASSEM5LIES 4. 2-V2' WIDE GALV. (U.ON.) METAL STUDS TO CEILING. MIN. 24' O.C., MAX GAUGE PER CHART 5ELOW, (25 GA. MINIMUM) 25 CSA Il' -0' MAX. L,NIBRACED 25 GA PARTITION NGT. 20 GA. 14'-0' MAX UNBRACED 20 GA. PARTITION NGT. 18 GA 1'I'-0' MAX. UV5RACED 18 GA. PARTITION NGT. 16 GA 20-0' MAX. U45RACED 16 GA PARTITION HGT. 5. CONCRETE WALL (EXISTING) 6. SUSPENDED ACOUSTICAL CEILING TILES 1. SOUND ATTENUATION INSULATION (OPTIONAL) FOR INTERIOR PARTITIONS STUDS ARE FASTENED TO TOP AND 50TTOM TRACK WITH 1 010 TEK SCREW EACH SIDE OF EACH STUD. 50TTOM TRACK IS FASTENED TO FLOOR WITH PAF AT 24 ' AND TOP TRACK IS 5RACED TO STRUCTURE A50VE IF AND AS REQUIRED TO RESIST AT LEAST 5 PSP. 1/2' COLD WATER SUPPLY 4 I NSTA-FLOC SCALE: 1/4' -1'-0' ISOLATION VALVE 1/2' HOT WATER TO FIXTURE HEATE INTERIOR WALL TO ELECTRICAL CONNECTION INSTANT TANKLESS ELECTRIC WATER HEATER. SURFACE MOUNT TO WALL IN UNDER COUNTER SPACE FLOG Ir �y 16 R E V I S 1 01 J O B N 0. 16006 D A T E 01/18/2016 S H E E T A3.1 6 0 F 8 GENERAL NOTES ALL SIZES ARE IN INCHES UNLESS OTHERWISE NOTED. ALL DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. THE FIRST DIMENSION INDICATED IS THE DIMENSION SHOWN. ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS AND TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED WHERE REQUIRED WITHOUT ANY REDUCTION IN THE CROSS-SECTIONAL AREA OF THE AFFECTED DUCT. ALL EQUIPMENT AND DUCTWORK SHALL BE SUPPORTED ACCORDING TO SMACNA STANDARDS. PROVIDE ADDITIONAL SUPPORT AS REQUIRED TO PROVIDE A VIBRATION -FREE RIGID INSULATION. SUPPLY, RETURN AND FRESH AIR DUCTWORK SHALL BE FIBERGLASS DUCTWORK LINED WITH ANTI -MICROBIAL INSULATION (EQUAL TO "SUPERDUCT") MIN. R-6 INSULATION TO COMPLY WITH FLORIDA ENERGY EFFICIENCY CODE (2014 ED.). ALL FIBERGLASS DUCT AND DUCT WRAP SHALL BE SEALED WITH GLASS FAB AND MASTIC. FLEXIBLE DUCT CONNECTORS SHALL NOT EXCEED 10' IN LENGTH. ALL SQUARE ELBOWS SHALL INCLUDE FACTORY -FABRICATED SINGLE THICKNESS TURNING VANES. ALL SUPPLY DIFFUSERS SHALL BE INSULATED FROM THE CEILING GRID. INSULATE DIFFUSER BACK AND NECK WITH R-6 BATT INSULATION. SEAL WITH GLASS FAB AND MASTIC. CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC. BUILD FIBERGLASS PLENUM BOX ABOVE ALL RETURN AIR GRILLES. DUCT INTO CENTER OF BOX. MOUNT THERMOSTATS AT 4'-4" A.F.F. CONTRACTOR SHALL PROVIDE AND INSTALL ENGRAVED PLASTIC NAME PLATED FOR ALL FANS AND EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. THE NAME PLATES SHALL INDICATE THE ROOM SERVED, ITEM NUMBER AND SHALL BE LOCATED BOTH ON THE EQUIPMENT AND WHERE POWER SHUT-OFF IS. PROVIDE TEST AND BALANCE FOR ALL AIR CONDITIONING SYSTEMS. TEST AND BALANCE SHALL BE IN ACCORDANCE WITH AABC STANDARDS. TEST AND BALANCE REPORT SHALL BE SUBMITTED TO OWNER. COORDINATE WITH ELECTRICAL CONTRACTOR TO PROVIDE 120V SERVICE OUTLET WITHIN 6' OF ALL EQUIPMENT. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA MECHANICAL CODE (2014 ED.), 2014 FLORIDA ENERGY CODE, AND MOST RECENT EDITIONS OF 2012 NFPA 90A, 2012 NFPA 101 W/ FLA. AMENDMENTS, ASHRAE, SMACNA, NEC AND THE LOCAL AUTHORITY HAVING JURISDICTION. WRAP SUCTION REFRIGERANT PIPING WITH MIN. 1/2" THICK CELLULAR RUBBER EQUAL TO ARMSTRONG ARMAFLEX. INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND SERVICE CLEARANCE REQUIREMENTS. COORDINATE WITH CONTRACTOR TO UNDERCUT ALL RESTROOM, STORAGE ROOM AND JANITOR CLOSET DOORS BY 3/4" FOR AIR TRANSFER. AIR DISTRIBUTION PLAN IS DIAGRAMMATIC ONLY AND IS PROVIDED FOR LAYOUT PURPOSES ONLY. CONTRACTOR IS RESPONSIBLE FOR COORDINATING DIFFUSER AND GRILLE LOCATIONS WITH LIGHTING PLAN AND CEILING GRID. HVAC HEX NOTES: IENEW SUSPENDED AIR HANDLER UNIT. FNEW CONDENSING UNIT ON ROOF DEGC (NOT SHOWN) F 3 1 EXI6TINCs EXHAUST AIR LOUVER -TIE NEW FAN TO EXISTING DUCT. ALL 1 /290 AIR BALANCE SCHEDULE TERMINALS ® SUPPLY REGISTER FRESH AIR REQ'D DESIGN FRESH AIR SPACE TYPE AREA N0. PEOPLE NEW FLEX DUCT CFM NEW 24/7 DIGITAL-PROGRAMABLE THERMOSTAT ROUTE CONDENSATE ZJ2 (20 CFM/PERS) OFFICES 135 6 120 120 FRESH AIR REQUIREMENTS BASED ON ASHREA 62.1-2004. UNDERCUT BATHROOM DOORS 1" FOR AIR RETURN ENTIRE RETURN AIR SYSTEM SHALL BE DUCTED EXCEPT FOR BATHROOMS SAG 1/2" `OOT OF SRT NG. AIR DISTRIBUTION SCHEDULE A LOUVERED CEILING DIFFUSER. 24 x24 FACE SIZE. NECK SIZE AS INDICATED ON DRAWINGS. ALUMINUM, WHITE FINISH, OPPOSED BLADE DAMPER. TTUS TMDC-AA OR EQUIVALENT, B EGGCRATE (RETURN GRILLE. 24 x 24 FACE WITH 22 x 22 NECK. ALUMINUM GRID WITH ALUMINUM BORDER, STANDARD CORE, WHITE FINISH, OPPOSED BLADE DAMPER. TITUS 50F OR EQUIVALENT. AIR CONDITIONING SCHEDULE AHU-1: NEW SUSP. HORIZONTAL AIR HANDLER, 18,000 BTUH TOTAL CAPACITY. 5.0 kW ELECTRIC STRIP HEATER. 600 CFM SUPPLY AIR, CARRIER MODEL FA4CNFO18 OR EQUIVALENT SUPPLY WITH ON/OFF/AUTO DIGITAL T -STAT. WEIGHT: 150# MOCP 60A OUTSIDE AIR: 120 CFM CU -1: NEW OUMOOR CONDENSING UNIT. 18,000 BTUH TOTAL CAPACITY, 13 SEER. MOCP 40A CARRIER MODEL 24ABR3018 OR EQUIVALENT. FAN SCHEDULE EF 2 : ffA CEILING EXHAUST FAN. 80 CFM 0 0.125" S.P. 2.5 SONES, 850 RPM, 115V POWER. INCLUDE WALL CAP AND TIME DELAY SWITCH. BROAN MODEL "HD 80" OR APPROVED EQUAL. INTERLOCK FAN OPERATION WITH LIGHTS. H"V.A.C. LEGEND TERMINALS ® SUPPLY REGISTER PROVIDE ANY ACCESSORIES RETURN REGISTER ® NEW EXHAUST FAN FLEX NEW FLEX DUCT rT,N -1 NEW 24/7 DIGITAL-PROGRAMABLE THERMOSTAT FLEXIBLE SUPPORTS DETAIL NOT TO SCALE SPIN—IN FITTING 7 RUN REFRIGERANT PIPING TO CONDENSING UNIT. SIZE LINES AS PER MANUFACTURERS 3/8' HANGER RODS SECURE RECOMMENDATIONS. TO STRUCTURE ABOVE. PROVIDE ANY ACCESSORIES VIBRATION ISOLATOR - MASON REQUIRED FOR VERTICAL HEIGHT. TYPE 'HD' FLEX FLEX CONNECTION CONNECTION ROUTE CONDENSATE ZJ2 TO DRYWELL. INSULATE AIR HANDLER PIPE 4 TRAP WITH 3/4' ~-- l a ARAFLEX WHERE THE PIPE IS RUN WITHIN THE BUILDING ... AND WHERE CONDENSATION o MAY CAUSE DAMAGE. O O PROVIDE ACCESSIBLE OC � FILTER RACK UNI -STRUT 4 3/8' ON "m FTI ALL THREAD ROD_ P -TRAP SECURE WITH FLAT (SEF DETAIL) WASHERS 4 WING NUTS. CONDENSATE DRAIN PAN - 3' HIGH X 3' LARGER THAN UNIT, l PAN SHALL BE 18 GA. GALV. SHEET. CROSSED BRACED AS SEAMS SHALL HIE SOLDERED. � _ , FULL SIZE ACCESS PANEL FLOAT CONTROL SHUT-OFF VALVE (SHUT UNIT OFF IN OVERFLOW CONDITIONS. r"'',IR HANDLER I R INSTALLATION DETAIL- SPIN—IN F_ AIL N.T.S. HANGER (TYP.) FLEX DUCT O.B. DAMPER NSULATE COLLAR AND TOP RIGID DUCT SIDE OF DIFFU ER WITH R-6 INSULATION W/ ALUM. JACKET. T—BAR FRAME----\ r SEAL ALL JOINTS WITH MASTIC. \—CEILING CEILING DIFFUSER DETAIL NOT TO SCALE (:D VIBRATION ISOLATION PAD (TYP. OF 4 CORNERS) ---� CONDENSING UNIT PREFABRICATED Mt-TAL SUPPORT (TYPICAL) AS MFR'D BY 'AES �\ ..��., INDUSTRIES, INC. ` MODEL NO. AES -1. PROVIDE 18GA. 2" WIDE SHEET METAL TIE -DOWN STRAP. CONNECT TO UNIT 3/8" BOLT NUT AND WASHER �� ' AND CURB USING 5 16" SELF -DRILLING (TYP. EACH CURB) >> SCREWS WASH RS (TP. OF 4 NOTES: 1.) SECURE CONDENSING UNIT TO ROOF PER LOCAL HURRICANE CODE REQUIREMENTS. 2. COORDINATE INSTALLATION WITH BUILDING OWNER AND COMPLY WITH ALL REQUIREMENTS NECESSARY TO MAINTAIN WARRANTY. CONDENSING UNIT SUPPPORT DETAIL NOT TO SCALE NOTE: MECHANICAL SCOPE OF WORK SHALL BE TO ADD (1) NEW SUSPENDED AIR HANDLER AND (1) NEW ROOF TOP CONDENSING UNIT WITH FLEX DUCTS & REGISTERS AS REQUIRED TO ACOMODATE (3) NEW OFFICES ADDED -rn ^mA ml ALI \II ^IIALIV^AI rnlllPtllr►17 rnn rVIL^TAI/% VnA/tiC ClUA1 I DEMAIAI WITU AIA PWAAIM' �ECHANICALPLAN : �i4' ■ 1'-m' AA C000606 R E V I S 1 0 2 Ll 02/25/16 Owner Req'd. Changes J 0 B N 0. 16006 D A T E 01/18/2016 S H E E T M0. 1 6 0 F 8 sI_ . nn M--�■I � c ccEl— �y ZJ2 C\2 M to a am o O O w OC � r- W w ct � W w4 W L' P:4 z a R E V I S 1 0 2 Ll 02/25/16 Owner Req'd. Changes J 0 B N 0. 16006 D A T E 01/18/2016 S H E E T M0. 1 6 0 F 8 sI_ o H � C9 �y ct o O O w OC � W w ct � R E V I S 1 0 2 Ll 02/25/16 Owner Req'd. Changes J 0 B N 0. 16006 D A T E 01/18/2016 S H E E T M0. 1 6 0 F 8 sI_ ELECTRICAL SPECIFICATIONS SECTION 16010 - ELECTRICAL GENERAL PROVISIONS 1. ALL WORK AND EQUIPMENT SHALL BE IN COMPLIANCE WITH THE FOLLOWING CODES AND STANDARDS: A. NFPA-101, LIFE SAFETY CODE. B. NFPA-70 (2011), NATIONAL ELECTRICAL CODE C. FLORIDA MECHANICAL CODE (2014) D. FLORIDA BUILDING CODE (2014). E. AMERICANS WITH DISABILITIES ACT . 2. ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECT, EXCEPT WHERE SPECIFICALLY NOTED ON THE PLANS TO BE RECONNECTED OR REUSED. 3. ALL SYSTEMS SHALL BE TESTED FOR PERFORMANCE VERIFICATION IN THE PRESENCE OF THE OWNER AT COMPLETION OF PROJECT. 4. VISIT THE JOBSITE PRIOR TO BID AN EXAMINE THE EXISTING CONDITIONS INCLUDE ALL MATERIAL AND LABOR FOR A COMPLETE INSTALLATION. SEC11ON 16050 - BASIC MATERIALS AND METHODS 1 ELECTRICAL CONNEC11ONS TO EQUIPMENT A PROVIDE POWER CIRCUIT WIRING FOR ALL EQUIPMENT REQUIRING ELECTRICAL POWER AND CONNECT COMPLETE UNLESS OTHERWISE INDICATED IN THE CONTRACT DOCUMENTS. B MOTOR HORSEPOWER AND EQUIPMENT SIZES SHOWN AND/OR SPECIFIED ARE ES11MATED AND SIZE OF WIRE, CONDUIT AND CIRCUIT PROTECTION DEVICES ARE BASED ON SAID ESTIMATE. ASCERTAIN THE ACTUAL HORSEPOWER AND CURRENT REQUIREMENTS, OF THE MOTORS AND EQUIPMENT TO BE INSTALLED, PRIOR TO BEGINNING INSTALLA11ONS OF FEEDERS FOR SAME. IF THE ACTUAL REQUIREMENTS ARE DIFFERENT, NOTIFY THE ENGINEER TO OBTAIN CLARIFICATION. C BALANCING ELECTRICAL LOAD: EXERCISE CARE IN CONNECTING THE VARIOUS ELECTRICAL LOADS TO THE PANELS IN ORDER TO ARRIVE AT A REASONABLE BALANCE BETWEEN LOADS IN EACH PHASE AT EACH PANEL MAKE TESTS AND ADJUST LOADS AT EACH PANEL TO RESULT IN A REASONABLY BALANCED LOAD CONDITION, SATISFACTORY TO THE U11LITY COMPANY, ENGINEER, OWNER AND INSPECTION AGENCIES. 2 WIRE AND CABLE - 600 VOLT A CONDUCTORS: 98% CONDUCTIVITY, SOFT DRAWN COPPER. B INSULA11ON: HEAT AND MOISTURE RESISTANT, THHN/THWN 600 -VOLT RATING C..USE STRANDED CONDUCTOR ON ALL WIRING #6 AWG AND LARGER. ALL OTHER WIRING MAY BE SOLID. System No. W -L-1001 June 15, 2005 3 WIRING DEVICES A PROVIDE SWITCHES AND RECEPTACLES AS MANUFACTURED BY HUBBELL, PASS & SEYMOUR, LEVITON, ARROW -HART OR GENERAL ELECTRIC. B DUPLEX RECEPTACLES: 20 AMP, 120 VOLT, HEAVY DUTY, COMMERCIAL GRADE, GROUNDING TYPE MEETING THE REQUIREMENTS OF FED. SPEC. WC -596, NEMA WD -1, AND UL -498. C LIGHT SWITCHES: 20 AMP, 120/277 VOLT, HEAVY DUTY, COMMERCIAL GRADE, QUIET TYPE MEETING THE REQUIREMENTS OF FED. SPEC. WS -896 AND NEMA WD -1. D USE SMOOTH STYLE, 0.10" THICK, PHENOLIC OR UREA PLASTIC PLATES. MATCH COLOR OF PLATE WITH COLOR OF DEVICE. PROVIDE PLATES FOR ALL SWITCHES, RECEPTACLES, TELEPHONES AND ALL UNUSED JUNCTION BOXES. E ALL DEVICES SHALL BE DECOR STYLE, WHITE. 4 GENERAL REQUIREMENTS A USE GOOD WORKMANSHIP IN THE INSTALLATION OF ALL ELECTRICAL MATERIALS AND EQUIPMENT. INSTALL EQUIPMENT LEVEL, PLUMB AND TRUE WITH THE STRUCTURE AND OTHER EQUIPMENT. FIRMLY SECURE ALL MATERIALS IN PLACE AND ADEQUATELY SUPPORTED AND PERMANENT. MATERIALS EMBEDDED IN CONCRETE OR MASONRY OR OTHERWISE PART OF THE STRUCTURE ARE CONSIDERED SUFFIC-IENTLY SUPPORTED. USE HARDWARE AND ACCESSORY FITTINGS OF A TYPE DESIGNED, INTENDED AND APPROPRIATE FOR THE USE AND COMPLEMENT THE ITEMS WITH WHICH THEY ARE USED. 5 MINIMUM SIZES A CONDUIT. 1/2" FOR SWITCH LEGS AND BRANCH CIRCUITS. E WISE INDICATED. 3/4 -FOR ALL HOMERUNS UNLESS 0THRE B WIRE: #12 AWG FOR ALL POWER AND LIGHTING CIRCUITS. SIGNAL AND CONTROL WIRING MAY BE SMALLER, AS INDICATED. #10 AWG FOR ALL HOMERUNS UNLESS OTHERWISE INDICATED 6 WIRING METHODS A INSTALL ALL WIRING IN CONDUIT OR APPROVED RACEWAYS UNLESS OTHERWISE INDICATED. CONCEAL THE CONDUIT AND OUTLET INSTALLATION IN WALLS, ABOVE FINISHED CEILINGS, UNDERGROUND OR UNDER FLOOR AS SHOWN ON DRAWINGS. CONDUITS MAY BE RUN EXPOSED ON WALLS AND CEILINGS OF ELECTRICAL ROOMS, MECHANICAL ROOMS, AND/OR OTHER LOCATIONS AS INDICATED. B UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS, PROVIDE CONDUIT IN ACCORDANCE WITH THE F Ratings - 1, 2, 3 and 4 Hr (See Items 2 and 3) T Ratings - 0, 1, 2, 3, and 4 Hr (See Item 3) L Rating At Ambient - less than 1 CFM/sq ft L Rating At 400 F - less than 1 CFM/sq ft SECTION A -A FOLLOWING: RIGID METAL CONDUIT (RMC): ANYWHERE EXCEPT CORROSIVE ENVIRONMENTS INTERMEDIATE METAL (IMC): ANYWHERE EXCEPT CORROSIVE ENVIRONMENTS THINWALL METAL (EMT): ANYWHERE EXCEPT AS FOLLOWS: UNDERGROUND. IN SLABS ON GRADE. CORROSIVE ENVIRONMENTS. SCHEDULE 40 AND 80 PVC: UNDERGROUND ONLY. CORROSIVE ENVIRONMENTS: USE RMC OR IMC COATED IN ACCORDANCE WITH NEC 300-6. MC CABLE IS GENERALLY ACCEPTED WHERE ALLOWABLE BY LOCAL CODE AND APROVED BY OWNER. C USE FLEXIBLE STEEL CONDUIT WITH GROUND WIRE FOR FINAL CONNECTION TO MOTORS AND LIGHT FIXTURES. USE SEAL11TE IN DAMP OR CORROSIVE ATMOSPHERES. D DO NOT PULL CONDUCTORS INTO CONDUITS UNTIL ALL WORK WHICH MAY CAUSE DAMAGE TO THE WIRES IS COMPLETED. INSTALL WIRE AND CABLES SO AS NOT TO DAMAGE THE INSULATION OR CABLE SHEATH. PULL ALL CONDUCTORS TO BE INSTALLED IN A RACEWAY TOGETHER. TRAIN AND GUIDE WIRES INTO THE RACEWAY USING A PULLING COMPOUND OR LUBRICANT WHEN NECESSARY. PROVIDE A MEANS OF COMMUNICA11ON BETWEEN THE PULLING AND GUIDING POINTS TO FACILITATE INSTALLATION AND TO HELP PREVENT DAMAGE. USE A PULLING MEANS THAT WILL NOT DAMAGE THE RACEWAY. E KEEP CONDUCTOR SPLICES TO A MINIMUM. PROVIDE SPLICES AND TAPS WITH AT LEAST THE EQUIVALENT MECHANICAL STRENGTH AND INSULATION AS THE CONDUCTORS. PROVIDE SPLICE AND TAP DEVICES 0F THE PROPER SIZE I AND TYPE FOR THE USE AND COMPATIBLE WITH THE CONDUCTOR MATERIAL. ALL SPLICES SHALL BE MADE IN JUNCTION BOXES OR TERMINAL CABINETS. NO SPLICES SHALL BE PERMITTED IN CONDUIT(S). 7. EQUIPMENT MOUNTING A INSTALL EQUIPMENT ON CEILING, WALL OR FLOOR AS INDICATED OR AS APPROPRIATE. PROVIDE FASTENERS OR SUPPORTS SUFFICIENT IN SIZE AND QUANTITY TO SUBSTANTIALLY SECURE THE EQUIPMENT IN PLACE TO THE BUILDING STRUCTURE OR STRUCTURAL ELEMENT. B INSTALL THE EQUIPMENT PLUMB, TRUE AS INTENDED AND SECURE. WHEN SEVERAL ITEMS OF EQUIPMENT ARE WALL MOUNTED IN THE SAME AREA, LINE THEM UP VERTICALLY AND HORIZONTALLY ALONG WITH ANY ASSOCIATED RACEWAYS. 1. Wall Assembly - The 1, 2, 3 or 4 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U40D Series Wail or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs (max 2 h fire rated assemblies) or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC with nom 2 by 4 in. (51 by 102 mm) lumber end plates and cross braces. Steel studs to be min 3-5/8 in. (92 mm) wide by 1-3/8 in. (35 mm) deep channels spaced max 24 in. (610 mm) OC. B. Gypsum Board* - Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft. (122 cm) wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 26 in. (660 mm). 2. Through -Penetrant - One metallic pipe, conduit or tubing installed either concentrically or eccentrically within the firestop system. The annular space between pipe, conduit or tubing and periphery of opening shall be min of 0 in / (0 mm). (point contact) to max 2 in. (51 mm) Pipe, conduit or tubing to be rigidly isupported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe - Nom 24 in. (610 mm) diam (or smaller) Schedule 10, (or heavier) steel pipe. B. Iron Pipe - Nom 24 in. (610 mm) diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in (305 mm) diam (or smaller) or Class 50 (or heavier) ductile iron pressure pipe. C. Conduit - Nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 4 in (102 mm) diam (or smaller) steel electrical metallic tubing D. Copper Tubing - Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing E. Copper Pipe - Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. F. Through Penetrating Product* - Flexible Metal Piping The following types of steel flexible metal gas piping may be used: 1. Nom 2 in. (51 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. OMEGA FLEX INC 2. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. GASTITE, DIV OF TITEFLEX 3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. WARD MFG INC 3. Fill, Void or Cavity Material* - Caulk or Sealant - Min 5/8. , 11-1,/4,1-7/8 and 2-1/2 in. (16, 32, 48 and 64 mm) thickness of caulk for 1, 2, 3 and 4 hr rated assemblies, respectively, applied within annulus, flush with both surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulk applied to gypsum board/penetrant interface at point contact location on both sides of wall. The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below: Max Pipe or Conduit Diam In mm F RATING Hr T RATING Hr 1 25 1 or 2 0+, 1 or 2 125 3or4 3or4 4 102 1 or 2 0 6 152 3 or 4 0 12 305 1 or 2 0 +When copper pipe is used, T Rating is 0 h. 3M COMPANY - CP 25WB+ or FB -3000 WT. *Bearing the UL Classification Mark 8. SLEEVES A WHERE CONDUITS PASS THROUGH SLEEVES IN EXTERIOR WALLS, CAULK THE ANNULAR SPACE WITH OAKUM AND FILL INSIDE AND OUT WITH A NON - HARDENING, WATERPROOF SEALANT FINISHED OFF FLUSH WITH BOTH FACES OF THE WALL. SECTION 16500 - LIGHTING 1. U.L. LABELS MUST APPEAR ON ALL LIGHTING FIXTURES. FLEXIBLE CONDUIT TAILS, UP TO SIX FEET IN LENGTH, MAY BE USED BETWEEN JUNCTION BOXES AND RECESSED LIGHTING FIXTURES. OUTLET BOXES MAY SERVE UP TO FOUR SEPARATELY RECESSED FIXTURES. BALLASTS SHALL BE ELECTRONIC HIGH-POWER FACTOR CBM LABELED. 2. PROVIDE PROPER TRIM PER REFLECTED CEILING PLAN OR ACTUAL CEILING INSTALLED. 3 PROVIDE LAMPS IN ALL FIXTURES SECTION 16195 -ELECTRICAL IDENTIFICATION 4. EXIT SIGNS, EMERGENCY BATTERY PACKS AND EMERGENCY INVERTERS SHALL BE 1. PROVIDE EACH BRANCH CIRCUIT PANEL WITH A DIRECTORY INDICATING CONNECTED TO LOCAL CIRCUITY; AHEAD OF SWITCHING. LOADS SERVED. THE PANEL SCHEDULES SHOWN ON THE PLANS DO NOT SECTION 16740 - COMMUNICATIONS SYSTEM CONTAIN ADEQUATE INFORMATION TO BE COPIED AND USED AS PANEL 1. PROVIDE 3/4"X2'X2' HIGH PLYWOOD BACKBOARDS IN LOCATION SHOWN ON DRAWINGS. NO PAINT WITH FIREPROOF GREY PAINT. PROVIDE #6 INSULATED COPPER GROUND WIRE DIRECTORIES. LABEL EACH CIRCUIT WITH ACTUAL ROOM NUMBERS OR FROM BACKBOARD TO SERVICE GROUND. ROOM NAMES SERVED, SUCH AS "RECPT 109, 110, 111". 2. EACH OUTLET SHALL BE PROVIDED WITH (1) 3/4"C STUBBED TO CEILING SPACE. 2. USE ENGRAVED PLAQUES FOR LABELING LARGE EQUIPMENT. 3. PROVIDE (1) 1-1/4"C. FROM TENANT TTB TO BUILDING TTB. 3. LABEL EACH POWER JUNCTION BOX WITH AN INDELIBLE MARKER 16720 - FIRE ALARM AND DETECTION SYSTEM INDICATING THE CIRCUIT NUMBERS CONTAINED WITHIN. 1. EXTEND EXISTING FIRE ALARM SYSTEM PER THE NATIONAL FIRE SECTION 16400 - SERVICE AND DISTRIBUTION ALARM CODE (NFPA 72) AND A.D.A. 1. PANEL BOARDS SHALL HAVE LOCKING COVERS AND USE BOLT -ON CIRCUIT 2. ALL WIRING SHALL BE IN RACEWAY. 3. PROVIDE BATTERY BACKUP PER NFPA. PROVIDE CALCULATIONS BREAKERS. DESIGN BASIS IS SQUARE -D QOB OR EQUAL. PROVIDE SHORT AND SIGNED & SEALED PERMIT DRAWINGS BY THIRD PARTY. CIRCUIT RATINGS AS INDICATED ON THE PLANS. 4. MOUNT PULL STATIONS 48" AFF; HORN/STROBES 80" AFF. 2. DISCONNECTS FOR U.L LISTED EQUIPMENT SHALL BE MATCHED TO THE DESIGN IS BASED ON 75CANDELA STROBES. NAMEPLATE REQUIREMENTS OF THE EQUIPMENT AS SUBMITTED BY THE 5. PROVIDE ALL ADDITIONAL HARDWARE FOR CONTROL PANEL LTNURW REQUIRED TO OPERATE ALL NOTIFICATION AND CONTROL APPLIANCES MECHANICAL CONTRACTOR. IT IS UNDERSTOOD THAT MANY KINDS OF 6. INSTALLER SHALL BE "E.F." LICENSED, SHALL OBTAIN PERMIT, DESIGN CHANGES, VALUE ENGINEERING CHANGES, AND BRAND NAME AND SHALL PROVIDE CERTIFICATION PER NFPA OF COMPLIANCE AT SHOPPING OCCUR BETWEEN THE TIME THESE PLANS ARE MADE AND THE JOB COMPLETION. TIME OF FINAL EQUIPMENT PURCHASE. VERIFY FINAL EQUIPMENT RATINGS 7. ALL DEVICES TO BE U.L LISTED TO FUNCTION WITH EXISTING WITH SUBMITTALS. CONTROL PANEL 8. ALL WORK SHALL BE PROVIDED BY THE OWNER'S SERVICE WARRANTY CONTRACTOR. 3. IN FUSED SWITCHES, PROVIDE DUAL -ELEMENT FUSES SIZED PER EQUIPMENT NAMEPLATES. 4. TOGGLE TYPE SWITCHES MAY BE USED AS DISCONNECTS WHERE SHOWN ON THE PLANS. PROVIDE PROVISIONS FOR LOCK -OUT. SEC11ON 16450 - GROUNDING 1. PROVIDE GROUND CONDUTORS IN ALL CONDUITS. 2. PROVIDE GROUNDING BUSHINGS FOR FEEDER CONDUITS. 3• SERVICE GROUND RESISTANCE SHALL BE MEASURED WITHOUT DEPENDING ON WATER PIPING SYSTEM AND SHALL BE 25 OHMS OR LESS, IF GREATER THAN 25 OHMS, DRIVE ADDITIONAL GROUND RODS TO OBTAIN REQUIRED RESISTANCE. 4' BGL AM MOX ROVIDE FIRE -RATED PUTTY IN BOXES IN FIRE -RATED WALLS. 24" MINIMUM T4' MIN. RIGID OR EMT CONDUIT CONNECT GROUNDING LUGS OF RECEPTACLES #12 WIRE SEE ARCHITECTURAL PLANS FOR WALL CONSTRUCTION BACK TO BACK ELECTRICAL OUTLETS DETAIL N.T.S. NOTE: BACK-TO-BACK OUTLET BOXES ON RATED WALLS AND PARTY WALLS SHALL BE SEPERATED BY A MINIUM 24" LIGHTING FIXTURE SCHEDULE TYPE LAMPS DESCRIP11ON MANUFACTURER / CATALOG NUMBER SEE NOTE NO TYPE A 3 F32T8 20 LAY -IN FLUORESCENT WITH ACRYLIC LENSE LIGHTOLIER XP2GVA332SOHPFU 1,2 EM 2 5.4 WATT TUNGSTEN EMERGENCY BATTERY MIT -HIGH INTENSITY LIGHTOLIER E5 -W 1 X Q -i LED UNIVERSAL EXIT SIGN LIGHTOLIER ® LTNURW 1 7- V DATA /PHONE sS WALL OUTLET BOX AND SINGLE POLE SWITCH 1 NOTES: 1. LITHONIA AND DAYBRITE SHALL BE CONSIDERED EQUAL 2. ALL FLUORESCENTS TO HAVE ELECTRONIC BALLASTS. 3. ONLY NEW LIGHT FIXTURES SHOWN ON SCHEDULE -ALL OTHERS TO REMAIN. ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION WALL OUTLET BOX AND 20 AMP DUPLEX RECEPTACLE LLLL 2' x 4' LAY -IN FLUORESCENT LIGHT FIXTURE U� WALL OUTLET BOX AND 20 AMP DUPLEX RECEPTACLE RECESSED LIGHT FIXTURE �� Qi � MOUNTED ABOVE COUNTER EMERGENCY LIGHTS (BATTERY PACKS) GFC1 WALL OUTLET BOX AND 20 AMP GFI RECEPTACLE WPG=WEATHERPROOF GROUND FAULT Q -i WALL OUTLET BOX AND FIXTURE ® WALL OUTLET BOX AND SPECIAL RECEPTACLE ® CEILING OUTLET BOX AND EXIT LIGHT FIXTURE SHADING INDICATES FACE V DATA /PHONE sS WALL OUTLET BOX AND SINGLE POLE SWITCH � 20 AMP /---� BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN Hcc w� WALL 1 ALL NtW UU11IJ QC UUrLtA KtUtrIMtiLL VU ILL IJ 1V IIL IV LmrII CIRCUIT IN EXISTING PANEL AA 0000606 R E V I S 1 0 Q02/25/16 Owner Req'd. Changes J O B N 0. 16006 D A T E 01 /18/2016 S H E E T E0. 1 8 0 F 8 . nn F-�co w U� �cc cc W �� Qi � rx o -0 Q a� � w �J2 � W Hcc w� x � J, w o c� R E V I S 1 0 Q02/25/16 Owner Req'd. Changes J O B N 0. 16006 D A T E 01 /18/2016 S H E E T E0. 1 8 0 F 8