Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
440 Rocky Grove Ln 17-1945 (a)
THORNBROOK 4011's COMMUNITY SPECIFIC STANDARD SPECIFICATIONS MONO FOOTING, ALUMINUM OVER 2x6 6UE3 F45CIA, 5HINGLE ROOF, ELECTRIC NEAT, 50 GAL. ELECTRIC W.H., 150 AMP SERVICE/PANEL BOX, PAVER DRIVE, PAVER LEAD WALK, PAVER ENTRY AND ACRYLIC AT LANAI, LOT 288 - THORNBROOKE 40I s PRESTON - 1989 - ELEV. "A" GARAGE RIGHT TAYLOR MORRISON REDRAW NOTES 03-23-11 CREATED Lot SPECIFIC PLAN FOR LOT 28a IN THORNE3ROOKE,40'5, ELEVATION "A" GARAGE RIGHT W/ PLAN OPTION5 INCLUDING: ADDITIONAL DOOR AT MA5TER 5ATH, UNDER CAE3INET LIGHTING, CAT 6 DATA OUTLET5, CEILING FAN PRE-WIRE5 AND RECE55ED CAN L IGHT5. PLAN REVISIONS DRAWING INDEX COV -GENERAL NOTES, INDEX, SPECIFICATIONS 1 -SLAB INTERFACE PLAN 2A1 -MAIN FLOOR PLAN NOTES 2A2 -MAIN FLOOR PLAN DIMENSIONS 2B1 -UPPER FLOOR PLAN NOTES 2B2 -UPPER FLOOR PLAN DIMENSIONS 2C -INTERIOR ELEVATIONS, STAIR SECTION, DETAILS 3A1 -FRONT ELEVATION 3A2 -SIDE ELEVATIONS, ROOF PLAN, BUILDING SECTION 3A3 -FLASHING DETAILS 3A4 -FLASHING DETAILS 4A -MAIN FLOOR ELECTRICAL PLAN 4B -UPPER FLOOR ELECTRICAL PLAN RF(101\11) COPY REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER DATE SANF-08 BUI INr lSION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS COOE COMPACTION TEST U QUIRED Results to be Verified at Slab Inspection #1 7 - 1 9 45 ING ORw OEF�AR�` GENERAL CON5TRUCTION NOTES: CHAPTERS AND SECTIONS REFER TO F,B.C.R. - 5TH EDITION (2014). NOTE: ANY DIMENSIONS AND/OR CALLOUT5 WITHIN THI5 SET OF DRAWINGS REFERENCING LUMBER SIZES SR WALL THICKNESS ARE TO BE CONSIDERED "NOMINAL DIMEN5ION5" OCCUPANCY AND CON5TRUCTION TYPE: THI5 UNIT HAS AN R3 OCCUPANCY AND BUILDING TYPE V-B CLASSIFICATION. f EXTERIOR WALL ENVELOPE: BUILDER IS RESPONSIBLE FOR PROVIDING AND MEETING ALL REQUIREMENTS OF SECTION 1012.4 OF THE F,B.C.-BUILDING BY PROVIDING ALL DETAILS LISTED UNDER THI5 SECTION, INCLUDING BUT NOT LIMITED TO, THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ALL SUPPORTING DOCUMENTATION TO ENSURE THE WEATHER RE515TANCE OF THE EXTERIOR WALL ENVELOPE 15 MAINTAINED. CEILING CON5TRUCTION: I. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LE55 THAN 5/8 INCH 05.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT, WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT IN ACCORDANCE WITH F.B,C.R. - 5TH EDITION (2014) R102,3.5. EXTERIOR FIN15HE5: INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. - 5TH EDITION (2014) R103.6.1 AND A5TM C 1063. ALL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIAL. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 11/2 INCH 11 GAUGE NAILS HAVING A 1/16 INCH HEAD, OR 116 INCH LONG 16 GAUGE STAPLES 5PACED NO MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED, THICKNE55 OF TEXTURED FINISH OVER FRAME APPLICATION TO BE PER F.B:C.R. - 5TH EDITION (2014) R103.6.2 AND A5TM C 926. , PER F.B.C.R. 5TH EDITION (2014) R103L,2.1 WEEP SCREEDS SHALL BE A MINIMUM NO.26 GALVANIZED SHEET GAUGE CORRO510N-RE5ISTANT WEEP SCREED OR PLASTIC WEEP SCREED WITH A INIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES SHALL BE PROVIDED AT OR BELOW THE PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH A5TM C 926. THE WEEP SCREED 5HA L BE PLACED A MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE PAVED AREAS. THE WEATHER RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SH LL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. PER F.B.C.R. 5TH EDITION (2014) R103b.3 WATER RE515TIVE BARRIERS INSTALLED OVER WOOD BASED SHEATH„ G SHALL INCLUDE A WATER RESISTIVE VAPOR PERMEABLE BARRIER EQUIVALENT TO 2 LAYERS OF GRADE D PAPER. STUCCO APPLICATION AND CURING PER F.B.C.R: 5TH EDITION (2014) R103.6.5 OR IN ACCORDANCE WITH A5TM C 926, 5TUCCO CONTROL JOINTS: .e x m r1 Jq� 0 -1 mm W T > > J M • L. �0LLOr- 0 0 a za� 0 6 CO E ca r -J ro� 0 o T Z coN L V STUCCO CONTROL JOINTS TO BE INSTALLED PER A5T0 C 1063-06 (1,IIAI THRU 1.11.4.4) AT FRAMED WALLS TO DELINEATE AREAS NOT MORE THAN 144 W. AND DELINEATE AREAS NOT MORE THAT 100 SF, FOR HORIZONTAL APPLICATIONS. DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18 FT. IN EITHER DIRECTION OR A LENGTH -TO -WIDTH RATIO OF 2 1/2 TO 1. A CONTROL JOINT SHALL BE r����..�� •.t INSTALLED WHERE CEILING FRAMING OR FURRING CHANGE DIRECTION, AND WHERE EXFIAN51ON JOINT OCCURS IN BASE EXTERIOR WALL. WALL OR PARTITION HEIGHT DOOR FRAMES SHALL BE CONSIDERED AS CONTROL JOINTS EGRE55: I. EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRESS CODES, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FINISH FLOOR LINE OF THAT PARTICULAR ROOM, FL45HING: I. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS, 2. APPROVED CORR0510N-RE515TANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH, APPROVED CORRO51ON-RE516TANT FLASHING SHALL BE INSTALLED AT ALL REQUIRED LOCATIONS PER R103.8, WINDOW IN5TALLATION: I. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTI 1FRS WRITTEN INSTALLATION INSTRUCTIONS, WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. DWELLING / GARAGE OPENINGS: Cn e- c Uj a:. M THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LE55 THAN 1 3/5" IN THICKNESS, SOLID CORE (S.C.) OR HONEYCOMB CORE STEEL DOORS' NOT LE55 THAN 13/8" THICK, OR 20 MINUTE FIRE RATED DOORS EQUIPPED WITH A SELF -CLOSING DEVICE. I I coJ 00 DAVIS BEWS DESIGN GROW 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TAMPA • DE"NVER. _.a EST. 1994 FLOOD ZONE REQUIREMENTS: PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION, d � A5PHALT SHINGLES (IF APPLICABLE) : C) Ell I. WIND RE515TANCE OF ASPHALT SHINGLES. - ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION RW52,6 AND RW5.2.6.1. r®01bi1I9� �' 2. ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER. FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LE55 THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING WITH A5TM D 226, TYPE I OR TYPE 11, A5TM D 4869, TYPE II OR �® ��°®°°®®°® �� s✓o TYPE IV OR A5TM D 615115 REQUIRED IN ACCORDANCE WITH SECTION R905.2.1, FOR ROOT" SLOPES FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12) AND GREATER, ONE LAYER OF ®®®®r®,® •°®® ®� UNDERLAYMENT COMPLYING WITH ASTM D 226, TYPE II, A5TM D 4869, TYPE IV OR A5TM D 6151 15 REQUIRED IN ACCORDANCE WITH SECTION R9052.1: LMI® 0�X�` CLAY AND CONCRETE TILE CIF APPLICABLE) ® z THE INSTALLATION OF CLAY AND CONCRETE TILE PER FB.C.R. - 5TH EDITION (2014) R905.3 SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'5 INSTALLATION IN5TRUCTION5, SR �2y®�®® �,' RECOMMENDATIONS OF FR5A/TRI FLORIDA HIGH WIND CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL,FIFTH EDITION WHERE THE VABD 15 DETERMINED IN ACCORDANCE WITH SECTION R301,2.1.3 !�,�® 61 OR THE RECOMMENDATIONS OF RA5 115,119 OR 120, REQUIRED UNDERLAYMENT PER FFiCR 5TH EDITION (2014) R905,33 SHALL CONFORM WITH A5TM D 226, TYPE II; A5TM D 2626, TYPE II; OR A5TM D 1910 OR ASTM D 6350, CLA55 M MINERAL SURFACED ROLL ROOFING AND SHALL BE NSTALLED IN ACCORDANCE WITH FR5A/TRIFLORIDA HIGH WIND CONCRETE AND CLAY ROOF TILE ®® t161 ®e INSTALLATION MANUAL, FIFTH EDITION WHERE THE VAsp 15 DETERMINED IN ACCORDANCE WITH SECTION R301.21.3 OR THE RECOMMENDATIONS OF RAS 118,119 OR 120. CHIMNEY HEIGHT REQUIREMENTS (IF APPLICABLE) I. WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE INSTALLED THE CHIMNEY MUST EXTEND 3'-0" PAST THE HIGHER POINT WHERE IT EXTENDS THROUGH THE ROOF AND MUST BE T-0" HIGHER THAN THE ROOF OR RIDGE THAT 15104" AWAY OR CLOSER. TUE3 AND 5HOWER ARE45: I. CEMENT, FIBER -CEMENT, OR GLASS MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH A5TM 5268, CI325, OR CI118 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, AND WALL PANELS IN SHOWER AREAS. IV TERMITE PROTECTION: POMMI I. PENETRATION. PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS SHALL NOT BE OF CELLULOSE CONTAINING MATERIALS. IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE A MAXIMUM WALL THICKNESS OF 0.010 INCH, AND BE SEALED WITHIN THE SLAB U51NG A NON -CORROSIVE CLAMPING DEVICE TO ELIMINATE THE ANNULAR SPACE BETWEEN THE PIPE AND THE SLEEVE. NO TERMITICIDE5 SHALL BE APPLIED IN51DE THE SLEEVE. 2, PROTECTION AGAINST DECAY AND TERMITES. - CONDENSATE LINES, IRRIGATION / SPRINKLER SYSTEM RISERS FOR SPRAY HEADS, AND ROOF DSWN5POUT5 SHALL DISCHARGE AT LEAST, I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN 6 INCHES (152 mm) HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF, MECHANICAL AND HVAC: I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO THI5 PLAN SET AT THE TIME OF APPLICATION FOR PERMIT, 2. MECHANICAL APPLIANCES SHALL BE ACCE551BLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER ' PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED, A LEVEL WORKING SPACE AT LEAST 30 INCHES (162 mm) DEEP AND 30 INCHES (162 mm) WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE, 3, DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. "26GAUGE (0.46 mm) SHEET STEEL 00 OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3 INCHES (16 mm) ABOVE THE FINISHED GRADE AND SHALL AL50 CONFORM TO THE 00 MANUFACTURER'S INSTALLATION INSTRUCTIONS 5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM, THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF SECTIONS M14113, EXHAU5T FANS AND VENTING: 1, OUTDOOR DISCHARGE, THE AIR REMOVED BY EVERY MECHANICAL EXHAUST 5Y5TEM SHALL BE DISCHARGED TO THE OUTDOORS. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE, 2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATE[) WITHIN A RESIDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHER AREAS INSIDE THE BUILDING, 3. DUCT LENGTH, THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 35 FEET FROM THE DRYER LOCATION TO THE WALL OR ROOF TERMINATION. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0,19 RAD) BEND AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.6 RAD) BEND, THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT, EXCEPTION - WHERE A CLOTHES DRYER 5005TER FAN 15 INSTALLED AND LISTED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF THE EXHAUST DUCT, INCLUDING ANY TRAN51TION DUCT, SHALL BE PERMITTED TO BE 1N ACCORDANCE WITH THE BOOSTER FAN MANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE A CLOTHES DRYER BOOSTER FAN 15 INSTALLED AND NOT READILY ACCESSIBLE FROM THE ROOM IN WHICH THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL BEAR THE WORDS "THI5 DRYER EXHAUST SYSTEM 15 EQUIPPED WITH A REMOTELY LOCATED BOOSTER FAN." • 4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAUST LOCATIONS IN ACCORDANCE WITH AMCA STANDARD 550 IN FBC. 1989 ATTENTION GENERAL CONTRACTOR / 5UILDER: • • ISSUANCE OF PLANS FROM THI5 DRAFTER'S OFFICE SHALL NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OF ERROR 1N NOTES; DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER'S OFFICE FOR CORRECTION BEFORE COMMENCEMENT OF ANY CONSTRUCTION CORRECTION / REVISIONS. ANY REV1510N5 OR CHANGES; NOT RELATED TO THE TITLE • CORRECTION OF ERRORS THAT ARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY COVER SHEET GENERAL NOTES OTHER PARTY OTHER THAN THE DRAFTER'S OFFICE, THE DRAFTER SHALL NOT BE HELD RESPONSIBLE. REV. 09-29-2016 C cSHEET ov 3'4"x34" A/C PAD (SEE MECH. �LL CONTRACTOR FOR LOG.) ELEVATION - CONC. PAD I I/2" RECESS FOR S.G.D. 4" P.V.C.G.C. VERIFY ACRYLIC N ON PAD - 3/4" P.V.C. CONDENSATION DRAIN BY PLUMBER co m N I 5'.4" r, REFERENCE SHOWER TILE RECE56 SEAT ELEVATION_ 2 0 — ABV, (0 0'-D1' LU ELEVATION v % 4" P.V.G. - O 0141 _ _ x6 -AIR HANDLER 2x6- LINES FROM OPT. I IOPT. I WALL UPPER FLOOR LWASHER J LDRYER J / CONDENSATION �U�U Jj DRAIN BY �� —I— SINK 9 2, I„ r r, PLUMBER IS' 9" I Q% 4'-a W/ pl5f 4 6 a' PROVIDE WATER-- LINE FOR ICE MAKER - % TO OF REF. 3/4" RECESS K, co a FOR ENTRY DR. ELEVATION 1, l ) 0'-4" I r "i 50 GAL. - _ W.N. 5' 0" 3' 8" 8" 2' 8" 2' i" 2'-91/2" 3'-5 1/2" 9' 0" 8" PAVERS _ ELEVATION I c0 of �I � I U Q I I I I I I I d-- G.J------------ I ----------------- --------------- 6' I a, I c0 e0 I I I I I ELEVATION I I I I l ) 0'-6" i N.B. I I 1 1/2" RECESS FOR GAR. DR., 1'-8" I. 5'-4" I. 1'-8" I. 2'-8" PAVER DRIVE / LEAD WALK AA 3A3 16'-0" 2'-8" TAYLOR MORRISON USES BORA-CARE TO TREAT THE INTERIOR FRAMED WALLS TO PREVENT SUBTERRANEAN TERMITES G.C. VERIFY THAT DECO DRAIN S INSTALLED AT PLANTERS BETWEEN WALKWAY AND GARAGE x ro r0 Ja�0 o V/ 0(n�� r > j 04 L ` caa� ooG h �"V�ti o 0 7 0 0 '1 0 _� ' a � Qi L454. 60c Z cm .1 y DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDWAR, ELORMA 34677 813.925. 1300 TEL 813.925.1800 FAX W W W1)AV1SBEWS.COM `IAMPA • L?ENVER EST. 1994- ti9 0: cr) c 00 oa rr. 00 is Z CD m � J LL a Z co 00 oo >m N J 1989 TITLE • D I TERF P SLA ACE LAN N SLAB INTERFACE PLAN SCALE: 1/4" = I'-0" w � ram. �ww� w�. w■. ■�� REFER TO SHEET 242 FOR MAIN FLOOR PLAN DIMENSIONS PAD (SEE MECH, CONTRACTOR FOR LOC.) H.B. 3 - 26 5H. HD, AT 8'-0" * EGRESS MASTER SUITE 13'-10%12'-10" 9'-4" FLAT CLG. T.O.M. 9'-4" 9'-41' ' 2 5TORY CLG CLG. G.C. VERIFY ACRYLIC 91-0"x3'-0" ON PAD CONC. PAD 8-06-0 TEMP, 5.G.D. FAMILY ROOM 14'-6"xl6'-0" 2-STORY VOLUME 9'-4" FLAT CLG. W/ OPT. BONUS ROOM 1 � 2-Sx6-a M. BATH 110 TEMP. GL. ENCL.—OPENING-,, CLG. 2-4x6-a BFp a .v o � c� GLG, W.G. DINING ROOM OPENING I F 14'-6"x10'-0" ON 42" H. LOUT WALL 2' 0' TO UNDER r 9'-4" FLAT CLG. STAIRS QQ Q SEE TUB/SHOWER- TILE c DETAILS - IS H. TILE I STAIR DATA: SHOWER SEAT I IS RISERS AT H4N5EN — -- - x DRYER 1,38" EACH KNEE 42" H. BOX r 15H. IF — — 1 —VENT — � 10.00" TREADS WALL COUNTERTOP OPT.— —I I OPT. — T R/5 "F 42" H. LW45HER JLDRY_ER J o 0 x /--------- UTIL AIR HANDLER �PT. RAILING 9 ' _ 4" OO 42" UPPER LINES FROM FLAT CLG. UPPER FLOOR `' a YI— �; CABINETS 2-Sx(c-0 a --- -- SINK I o W/ D15P �� 9'.411 I 8 SOFFIT- CLG. ABOVE 2-Sx6-a - ARCH FROM / --LINE OF SECOND ` o O PAV. a'D. 1 9 4° 0" TO a' a° �� / FLOOR ABv. ao� KITCHEN BARREL ARCH 9'-4" FLAT CLG. 0 FROM a'-0" PWDR / CLG. To a' -a' 0 c; tD x i PAVERS I sF� c O.H.C. 5 .__,..-...-.,... I \� f i- 1' ,. Y 1 FLUSH FRAME ���� �NAL�STE LINE OF SECOND INSULATE TO FURRING FLOOR ABV. WALLS cv_ LL; NOTE: 50 GAL. Q < ENTRY ALL INTERIOR W.N. cv i 9'-4" PLT. HT. ANGLED WALLS s I ARE AT 45' (U.N.O,) F_- -- --- L<— --J 54"x2211 ATTIC ACCE55 FLAT HEADER 9' 4" " AT 8'-0A.F.F. A.F.F. GARAGE 20'--0"x2o'-O" 9, 41' 9'-4" PLT. HT. O LINE OF GARAGE DOOR IN OPEN POSITION ° ----_.---_.-------------� I I REFER TO SHEET 2A2 FOR MAIN FLOOR PLAN DIMENSIONS 1 I I o 16.0x1-0 O.N. GARAGE DOOR O N.B. 9' 4' PAVER DRIVE / LEAD WALK A.F.F. AA 3A3 TRUSSES 1/16 D.S.B:-� ,[� BEYOND -- qMw r l BLOWN INSULATION S ATTIC ACC ES D TAIL SCALE: 1/2" : 14 ALL EMERGENCY ESCALANDSCUEOPENINGS SHALL COMP10PER F.B,C.R. 5TH EDIT TYPICAL MASONRY — WINDOW SCHEDULE WINDOW WIDTHS 2011 2711 3T 5311 MINWINDOW CALL -OUTS (D" 26 12 5H 1/2 32 5H 22 5H 32 5H W = 39" (? 13 5H 1/2 33 5H 23 5H 33 5H 0 51" 14 5H I/2 34 51H 24 5H 34 5H 0 z 63" 0 15 5H 1/2 35 5H 25 5H 35 5H H z 72" 3: 16 5H 1/2 36 5H 26 5H 36 5H C.C. VERIFY MA50NRY OPENING5 FOR ALL WINDOW5, uj WINDOW 51ZE5 AND INSTALLATION MAY VARY PER I MANUFACTURE SPECIFICATION5. U, Z REFER TO FLOOR PLANS FOR 5TYLE OF WINDOW U5E1) 151NGLE HUNG-5H, GASEMENT- GSMT, OR FIXED GLA55- F.G.) • x • ro C 10 JO�O 0 J co 0) r 'n 00 � m *' N L 5°iL0 L. • 0 0 aaaa `0� GO E LLx c\1 L J - O ,_ Oto ((J 00 y� T Z N 01 • JOB NUMBER 27002.157 • CAD FILE NAME LOT 288 ISSUED 03-23-17 REVISED DAVIS SEWS DESIGN GROUP 130 STATE STREET EAST OLDSMAR, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TAN4PA • DENVER a EST. 1994 e, - c% cw z at W _ J LL. NN®i 40 „WOWODOG®< µ�' ® O0 ��®I� �•mmmmmsmm m�m�®0® Lf) 0 00 COY= 00 0 I.L. N HATCHING LEGEND >7 INSULATE WALL r MAIN FLOOR PLAN NOTES — SCALE; GARAGE RIGHT I t+l a /fI9rfj l I' 8" 5'-4" 1, 1'-&" 2'-8" 16'-011 M.O. 2'-8" S'-8" 11 21'-4" i x C r0 JO�O O -i c) � N c=0 c i ,2 �. > ; J cv L L oo�� ro= r 00 az.0ti 1 E > lL x 0 O cm i J 0 CC� ZNLd' N DAVIS BEWS DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813 .925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.C.OM TAMPA • DENVER EST. 1994 rr.��--- a M 00 0 fir%.. a z C) J ry // C-3 Q o rr D C � c O� 00 asga'�►e V /cem 0 00 neo 00 0 r%#4 F� >11"m 0 < REFER TO SHEET 2AI • FOR MAIN FLOOR PLAN NOTES 1989 MAIN FLOOR PLAN DIMENSIONS GARAGE RIGHT PROVIDE PAN AND UNDER A.I- 24" H. A/C PLATFOR' -1/16 0.5.5. TRU55E5 BEYOND K u C Uo l� 00 0 _j 0) N 2co�c L �>'JM L L °aLL or- 0 0 2 �-0ti .O J c Q. R N 0��~ ' Z N G 0 JOB NUMBER 27002,157 CAD FILE NAME LOT 288 ISSUED 03-23-17 REVISED DAVIS BEWS DESIGN GROVP 150 STATE STREET FAST OLDSMAR, FLORIDA 34677 813. 925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TANAPA • DEIVVER. EST. 1994 F=, cm � ao 00 BLOWN �o INSULATION ATTIC ACCESS DETAIL SCALE: 1/2" - I'-0" low.tea 0 Z Q cl- r C ALL EMERGENCY ESCAPE AND RESCUE ,'�®®®, ®°• ••°b,�®��s OPENINGS SHALL COMPLY WITH R310®� °� ®•°o a2®U �� PER F,B.C.R. - 5TH EDITION (2014). 'Camp �� 01 ... TYPICAL WOOD FRAME WINDOW SCHEDULE WINDOW WIDTHS 2011 24" 3611 48" f-- WINDOW CALL -OUTS H 2011 1018 F.G. 2018 F.G. 306 F.G. 4018 F.G. W _ 2411 1820 F.G. 2020 F.G. 3020 F.G. 4020 F.G. J Q 36" v 1830 5H 2O30 5H 3030 5H 4030 5H z 48" 0 1840 5H 2O40 5H 3040 5H 4040 5H --a z 60" s 650 5H 2050 5H 3050 5H 4050 5H 1211 1860 5H 2O60 5H 3060 5N 4060 5H 6 G.G. VERIFY M450NRY OPENINGS FOR ALL WINDOW5, w uj 51ZE5 AND IN5TALLATION MAY VARY PER FWINDOW MANUFACTURE 5PECIFICATION5. z • REFER TO FLOOR PLANS FOR 5TYLE OF WINDOW U5ED (51NGLE HUNG-5H, CASEMENT- C5MT, OR FIXED GLA55- RGJ CLEAR OPENING HEIGHT5 IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15 LOCATED MORE THAN 12 INCHE5 ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW 5HALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OPERABLE 5ECTION5 OF WINDOWS 5HALL NOT PERMIT OPENING5 THAT ALLOW PA55AGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHE5 OF THE FINISHED FLOOR PER F.B.C.R. - 5TH EDITION (2014) R3122 WINDOW FALL PREVENTION DEVICES AND WINDOW GUARD5, WHERE PROVIDED, 5HALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090 PER F.B.C.R - 5TH EDITION (2014) R312.2 UPPER FLOOR PLAN NOTES GARAGE RIGHT "" 1 o Z r� Q 0: d so �i 0 i�0 A®A®ssro' term`®e ne 0 00 0 Ir..L. W N >7 0 1989 CLEAR OPENING HEIGHT5 IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15 LOCATED MORE THAN 12 INCHE5 ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW 5HALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OPERABLE 5ECTION5 OF WINDOWS 5HALL NOT PERMIT OPENING5 THAT ALLOW PA55AGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHE5 OF THE FINISHED FLOOR PER F.B.C.R. - 5TH EDITION (2014) R3122 WINDOW FALL PREVENTION DEVICES AND WINDOW GUARD5, WHERE PROVIDED, 5HALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090 PER F.B.C.R - 5TH EDITION (2014) R312.2 UPPER FLOOR PLAN NOTES GARAGE RIGHT "" 1 o Z r� Q 0: d so �i 0 i�0 A®A®ssro' term`®e ne 0 00 0 Ir..L. W N >7 0 1989 T-6" 1'-6" VERIFY THESE CRITICAL DIMEN51ON5 TO EN5URE WINDOW6 ARE CENTERED ON OPENING BELOIU 3D'-(D° II' -II" Est . c x r0 J Lo o J co Y/ DAM 4 >>Jc) L ` • roc N o a5� �.. o-' Co LL� �rn 4-04 4 cp 0 0` ZN�a rc:3) -11 DAVIS BEWS DESIGN GROW 150 STATE STRFE T EAST OLDSMAR, FLORIDA 34677 813.925.1300 TEL. 813.925.1800 FAX WWW.DAVISBEWS.COM TAMPA • L?ENVER- _� EST. 1994 • TITLE UPPER FLOOR PLAN DIMENSIONS PLAN DIMENSIONSSHEETUPPER FLOOR 5CALE; 1/4" , I'-011 2B2 GARAGE RIGHT • co a ALL GUARDRAILS AND HANDRAILS TO COMPLY WIN F5C R301 AND TABLE R301.5 PER F.5.C.R. 5TH EDITION (2014). —36" H. CONTINUOUS 42" H GRA5PABLE Low WALL RAILING BEAM LINE OF 6'-0" MIN. HEAD CLEARANCE FLOOR 5Y5TEM 2x 5TRINGER5 \ Im.mm° ITYPJ 42�� H. I I � LOW WALL I° NasING 1--- (TYP.) LINE OF DOOR IN FOREGROUND I I 2x TREAD5 AND n, I I 77 Ix RISERS ITYP) 3/4I' PLYWD. DECKING BEAM FLOOR 5Y5TEM UNDER -STAIR PROTECTION ENCLO5ED ACCE551BLE 5PACE UNDER 5TAIR5 5HALL HAVE WALLS, UNDER-5TAIR SURFACE AND ANY SOFFIT PROTECTED ON THE ENCL05ED 51DE W/ 1/2 INCH GYPSUM BOARD PER F.B.C.R. - 5TH EDITION (2014) R302.1 • • x m w r1 JoLO0 OJ cu'o 0 sm N _ r a>�M ♦ /i On 0-� CO FL 0 rn 41 h p 4L(>U-04 ZN 'd'' DAVIS BEWS DESIGN GROW 150 STATE STREET EAST OLDSMAR, MORMA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TAMPA • DEIVVFR, � EST.1994 a m ( ii w cane ... cc0 z OQcr:_ iLJ cS 1 ®\0%J1111 I 111'rN co LL- �S. • ro W rr� w 0 00 -N 00 11 TREAD5 AT I0.00" EACH • STAIR SECTION ' SCALE: 1/4" _ '-0" 1989 PLAN DETAILSAr\r% GGE RIGHT 11/2" THICK 5AND FIN15H KEY5T0NE Z N u, L nc W � �5 o w z 3/4" THICK (IF APPLICABLE) RA15ED 5AND FIN15H TEXTURED BANDING NOTE: TH15 DETAIL 5110W5 THE TYPICAL THICKNE55 OF ALL RA15ED TEXTURED FIN15N BANDING AND 5AND FINI5HED KEY5TONE5 (WHERE APPLICABLE) IF THICKNE5516 TO BE DIFFERENT IT WILL BE CALLED OUT AT SPEGIFIC KEYNOTE CALL -OUT INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. - 5TH EDITION (2014) R103.6.1 AND A5TM C 1063, THICKNE55 OF TEXTURED 1`I4514 OVER FRAME APPLICATION TO BE PER F.B.C.R. - 5TH EDITION (2014) R103.6.2 AND A5TM C 926, TYP. CROSS-SECTION OF RAISED TEXTURED FINISH BANDING AND / OR SAND FINISH KEYSTONE 5CALE: 3" - 1'-0" CLEAR OPENING HEIGHTS IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15 LOCATED MORE THAN 12 INCHE5 ABOVE THE FIN15HED GRADE OR SURFACE BELOW, THE LOWE5T PART OF THE CLEAR OPENING OF THE WINDOW 5HALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINI5HED FLOOR OF THE ROOM IN WHICH THE WINDOW 15 LOCATED. OPERABLE 5EGTION5 OF WINDOW5 5HALL NOT PERMIT OPENING5 THAT ALLOW PA55AGE OF A 4 INCH DIAMETER 5PHERE WHERE 5UCH OPENING5 ARE LOCATED WITHIN 24 INCHE5 OF THE FIN15HED FLOOR PER F.B.C.R. - 5TH EDITION (2014) R312.2 WINDOW FALL PREVENTION DEVIGES AND WINDOW GUARD5, WHERE PROVIDED, 5HALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090 PER F.B.C.R. - 5TH EDITION (2014) R312.2 PLT. NT 4" BANDING --- (TYP.) 1'-2" W. x 44" H.- DECORATIVE FIXED SHUTTER 4" BANDING --- (TYP.) 5ECOND F.F. LINE T.O.M. 4" BANDING - __T TEXTURED FIN15H BANDING MAIN F.F. LINE _ 12 6G� ,/ SHINGLE ROOF 6 IT G.C. VERIFY ALUMINUM OVER 2x6 5UB-FA5CIA (TYPICAL) - - - - 5%CCO _ FIN15H -- - TEMP. ,� 12 - 5HINGLE 6 ROOF 6 12 BANDING 11 x ro w r r0 J to 1, 0 O'A _j co V/ 2 e� N > yM 5aU. • 00 aUah 0-� GO 3�ELLY �rn �Z C4 00 00 N CO 0 ZNv 12 a6 ze ININGLE ROOF PLT. HT. -- 5TU000 - - I'-4" W. x 5'-0" H. FIN15H — _ DECORATIVE -- FIXED 5HUTTER �t 00 - --- 6' L �6 DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TAMPA • IJENVER EST. 1994 t1j ti son d'I LL INGLE E®®®`N�� ROOF 5EGOND FF. LINqri� ,® ", " T.O.M. q + m ® U.,• p J �' • Q 6" BANDING �, tS� ee rT'• • w;�. 0 fit•°Gj*. �e r [7 F7 TTF7 F� T TEXTURED �- FIN15H MAIN F.F. LINE COPYRIGHT 2014, TAYLOR MORR15ON 4" BANDING -j GRADE LINE (ASSUMED) FRONT ELEVATION r") 'A 5CALE: 1/4" -- 1'-0" ELEVATION "A" GARAGE RIGHT 1989. • TITLE • FRONT ELEVATION DETAILS • SHEET • MAIN ROOF VENT REQUIREMENTS VENTILATION CALCULATIONS ATTIC AREA = 1126 SQ. FT. / 300 = 3.75 SQ. FT. X 144 = 540 SQ. IN. HALF AT UPPER 2/3 ROOF VENTS = 270.24 SQ. IN. # UPPER 2/3 ROOF VENTS REQUIRED = 2 HALF AT LOW SOFFIT / EAVE VENTS = 270.24 SQ. IN. ACTUAL SOFFIT VENTILATION = 629 SQ. IN. VENT CALCULATIONS BASED ON THE FOLLOWING * 144 SQ. IN. PER 4 FOOT OFF RIDGE VENT * 9.7 SQ. IN. PER LINEAR FOOT OF SOFFIT VENT IF MORE SOFFIT INTAKE VENTING IS REQUIRED REFER TO SHEET "RVD" FOR BOTH TILE AND SHINGLE ROOF APPLICATIONS. G C VERIFY QUANTITY OF ROOF / SOFFIT VENTS REQUIRED, PER MANUFACTURER'S SPECIFICATIONS OF N FREE AREA PER VENT. * * * i \P���� 6:12 � r I --------------- r I I � I 1'.0 I------- I + OVERHANG y- AT HIP i \� (U.N.O.) i 4Q I j I-- 6:12 6;12 -1------- LLI I � I I � I I I GARAGE ROOF VENT REQUIREMENTS VENTILATION CALCULATIONS ATTIC AREA = 557 SQ. FT. 1300 =1.86 SQ, FT. I j X 144 = 267 SQ, IN. I I HALF AT UPPER 2/3 ROOF VENTS=133.68 SQ, IN. # UPPER 2/3 ROOF VENTS REQUIRED = 1 j I HALF AT LOW SOFFIT / EAVE VENTS = 133.68 SQ. IN. ACTUAL SOFFIT VENTILATION = 423.6 SQ. IN, 343 ke ROOF PLAN. SCALE: 1/8" _ 1'-0" 11/2" THICK SAND FINISH KEYSTONE (IF APPLICABLE) RAISED -- SAND FINISH TEXTURED BANDING z O w Q Ck 3/4" THICK NOTE: THIS DETAIL SHOWS THE TYPICAL THICKNE55 OF ALL RAISED TEXTURED FINISH BANDING AND SAND FINISHED KEYSTONES (WHERE APPLICABLE) IF THICKNE55 IS TO BE DIFFERENT IT WILL BE CALLED OUT AT SPECIFIC KEYNOTE CALL -OUT INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C,R, - 5TH EDITION (2014) R103,6.1 AND ASTM C 1063. TPICKNE55 OF TEXTURED FIN15H OVER FRAME APPLICATION TO BE PER F.B.C.R. - 5TH EDITION (2014) R103.6.2 AND ASTM C 926, TI CROSS-SECTION OF RAISED TEXTURED FINISH BANDING AND / OR SAND FINISH KEYSTONE SCALE: 3" = 1'-0" CLEAR opENING WEIGNfi5 IN DWELLING UNITS, WHERE THE OPENING OF AN OFER45LE WINDOW IS LOCATED MORE THAN 12 INCHES A50VE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR PER F.B.C.R. - 5TH EDITION (2014) R312.2 WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS, WHERE PROVIDED, SHALL COMPLY WITH THE REQUIREMENT5 OF ASTM F 2090 PER FS.C,R, - 5TH EDITION (2014) R312.2 6 12 126 GIRDER GIRDER TRUSS ROOF TRUSSES TRUSS 12 7. AT 24" O.C. (TYPicaL) 61 12 ❑❑ R 3❑❑ LOFT GIRDER- 6�j - -2 STORY TRUSS - ROOF TRUSSES M VOLUME AT 24" O.G. -- - ❑ ❑ ❑ ❑ «' (TYPICAL) -• FLOOR SYSTEM - BEAM BEAM KIT. FAMILY ❑❑ GARAGE �� � � WDINING ❑❑ SECTION AA SCALE: 1/8" -- I'-0" a6 • • x ro CInJ r00 o� 0 Jc�m1Z� Yi '0�(�M > > J N Ln C O LL • 0 0��r rr 6 0 -� O E ��0� - 0 N .E it 0 00c 400 Z N L d • JOB NUMBER 27002.157 CAD FILE NAME LOT 288 ISSUED 03-23-17 REVISED 12 _ 6� LSNIN 12 ........� GLE ROOF 7 �6 SHINGLE /` ROOF PLT. Hr. PLT. Hr. _ STUCCO 0-TEMP, /5TUCCO FINISN . FIN15W 12 �� 6 a SHINGLE _ SECOND F.F. LINE 8 ROOF _SECOND F.F. LINE T.O.M_ - - T.O.M. sr TEXTURED TEXTURED FINISN7 �o FIN15W -� % TEMP. MAIN F.F. LINE oil,, MAIN F.F. LINE w a N 00 - - - - - - - - - - - - - - az GRADE LINE (ASSUMED) ( /1 �`�®�R11119SA/ � LEFT ELEVATION ®��4�®®• as 04 SCALE; 116" 1'-0" r DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TA APA • IDENVER EST. 1994 �- TM ®® OD • w 12 12 /SHINGLE PLT. HT, ROOF PLT, HT. �o /5TUCCO F.G. F.G. FINISN * z _ SECOND F.F. LINE SECOND.F.F, LINE 0 T.O.M. T,O.M. TEXTURED TEXTURED FINISH FINISH MAIN F.F. LINE _MAIN FF. LINE GRADE LINE (ASSUMED) REAR ELEVATION SCALE: 116" - I'-0 00 120 6� r 12 12 �/ Q6 J 6� SNINGLE - ROOF>= PLT. HT. LT. HT. PLT. HT. 0 /5TUCCO 6, 12 8' * r FINISN j 6� SHINGLE SECOND F.F. LINE ROOF/ SECOND FF. LINE SECOND_F.F. LINE `n T.O.M. - - T.O.M. T.O,M. 2' 0" ZTEXTURED � 1989 TEXTURED d. 6, FINISH MAIN F.F. LINE MAIN F.F. LINE GRADE LINE (ASSUMED) RIGHT ELEVATION SCALE; 1/8" - I'-0" m MAIN F.F. LINE F I F VATTC)N "A" • TITLE • SIDES AND REAR ELEVATIONS ROOF PLAN BUILDING SECTION DETAILS • SHEET • GARAGE RIGHT LL, ,uo BUILDING WRAP TO GO OVER FLASHING FLASHING TO BE FLEXIBLE SELF ADHESIVE TYPE (MIN 6" WIDE) PRECAST LINTEL TYPICAL FLASHING AT PRECAST AND EXTERIOR SHEATHING DF MATERIAL PER :VATIONS WITH APPROVED )ERLAYMENT (REFER TO JER SHEET) :-ENGINEERED ROOF JSSES AT 24" O.C. RRICANE STRAP PER DF FRAMING PLAN BRG. HGT. M. DRIP EDGE . FASCIA ITED ALUM. SOFFIT :ATH & EXT. FINISH NDOW FLASHING AS REQ'D WINDOW TRIM L. ADER TYPICAL WINDOW AND SLIDING GLASS DOOR "Z" FLASHING DETAIL OPTION - A )ODEN )ING SILL PLATE SEE NOTE #2 ' WALL SHEATHING NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW SILL PLATE 3. INSTALL SILL FLASHING AS SHOWN ABOVE 4. INSTALL FLASHING AROUND REMAINING WINDOW UNIT 5. WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS TYPICAL FLASHING DETAIL AT SILL PLATE TIE-IN WITH WEATHER RESISTIVE BARRIER: 1. INTEGRATE INSTALLATION OF WEATHER RESISTIVE BARRIER WITH FLASHING TO FORM WATER SHEDDING LAPS 2. SCORE & FOLD WEATHER RESISTIVE BARRIER ABOVE HEADER TO ALLOW FOR FLASHING INSTALLATION 4. INSTALL HEAD FLASHING UNDER WEATHER RESISTIVE BARRIER 5. FOLD WEATHER RESISTIVE BARRIER BACK OVER HEAD FLASHING AND SEAL WITH WEATHER RESISTIVE BARRIER TAPE FLASHING PROVIDE SELF ADHERED Z FLASHING UNDER S.G.D. AS SHOWN, PROVIDE 4' -1" BEAD OF CONST. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WATER PROOF CAULKING PROVIDE SELF ADHERED FLASHING LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6" / -------- 15/32 O.S.B. SHEATHING - BUILDING WRAP BEYOND RUBBER MEMBRANE BEYOND i - CAULK/SEALANT OR SOLDER BETWEEN PAN FLASHING i AND DECK FLASHING. i i EXTERIOR FINISH PER BUILDER - i V' WATERPROOF MEMBRANE �- 2X12 #2 SYP CONT LEDGER W/ (4) 1/4" X 4" LAG SCREWS SPACED EVENLY @ 24" O.C. MAX (EA. FLOOR TRUSS) - --- __ USP HTA20 STRAP EA. JOIST --TEXTURED CEMENT PLASTER FINISH TYPICAL DOOR FLASHING AT BALCONY EXTERIOR SHEATHING �F9T,y FOLD UP WEATHER FR RESISTIVE BARRIER & TEMPORARILY SECURE RFS JST TYPICAL SLIDING GLASS DOOR FLASHING DETAIL MECHANICALLY FASTEN AS NECESSARY IN CORNERS THROUGH FLASHING WEATHER RESISTIVE BARRIER TAPE �- (ASSEMBLED WINDOW) FLASHING HEAD FLASHING TIE-IN INSTRUCTIONS: ,,-FLASHING SILL PLATE (SEE DETAIL B FOR OPTIONS) WEATHER RESISTIVE BARRIER CORNER PATCH FLASHING NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2- INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS 3. MECHANICALLY FASTEN AS NECESSARY FOLD UP WEATHER RESISTIVE WEATHER BARRIER & TEMPORARILY SECURE RESISTIVE— BARRIER i EXTERIOR SHEATHING SILL PLATE 21 1 r, �� /- , -- / V DO NOT FLASH OVER BOTTOM NAILING FLANGE � 2 i FLASHING NOTES: 1. CUT, FOLD UP & TEMPORARILY SECURE WEATHER RESISTIVE 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) BARRIER ABOVE HEADER TO ALLOW FOR FLASHING 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW INSTALLATION SILL PLATE 2. INSTALL HEAD FLASHING UNDER 3. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS WEATHER RESISTIVE BARRIER 4. INSTALL FLASHING AND WEATHER RESISTIVE 3. FOLD WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS BARRIER BACK OVER HEAD FLASHING AND SEAL WITH TAPE TYPICAL WINDOW FLASHING DETAIL 2X4'S @ 16" O.C. BRG EXT WALL - FLASHING TO EXTEND 36" - I 7/16" O.S.B. SHEATHING �- EXTERIOR FINISH BUILDING WRAP BEYOND PER BUILDER FLASHING. BOOTIDE AT PO TSING CEMENT PLASTER STOP WATERPROOF MEMBRANE WATERPROOF MEMBRANE 7/16" O.S.B. SHEATHING FLASHING. i 'FLOOR TRUSS `--2X8 TRIM BOARD STUCCO "J" MOLD PROVIDE SELF ADHERED 7/16" O.S.B. SHEATHING FLASHING LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6" ---- - SEE STRUCTURAL FOR CONNECTORS 24" FLOOR TRUSS %> �-TEXTURED CEMENT SEE STRUCTURAL PLASTER FINISH 8' CMU BLOCK • K Lo C �0 o tt) 0 J co Y/ 2 sm 0 , V > >JM L ` odd, • 00 0 -i C 0 Y >E r -J to o 20 T zc,4 TYPICAL FLASHING AT BALCONY II WALL COVERING 2014 FBRC SECTION R703 EXTERIOR COVERING EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.8. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER -RESISTIVE BARRIER BEHIND THE EXTERIOR VENEER AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO THE EXTERIOR WALL THAT ENTERS THE ASSEMBLY. PROTECTION AGAINST CONDENSATION IN THE EXTERIOR WALL ASSEMBLY SHALL BE PROVIDED IN ACCORDANCE a: ,v 00 WITH SECTION R702.7 OF THE CODE. v C -..I' R703.2 WATER -RESISTIVE BARRIER -' ONE LAYER OF APPROVED WEATHER -RESISTANT MATERIAL, FREE FROM HOLES AND BREAKS, COMPLYING WITH "" ®®��®w°®®a��,� 1 ®®®� ASTM D 226 FOR TYPE 1 APPROVED WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ��®, ���:o••°°"• °���,i �, ALL EXTERIOR WALLS. SUCH MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES 51 MM . WHERE JOINTS OCCUR, MATERIAL SHALL BE LAPPED NOT <LESS • W ( ) I LI m ao a:* , THAN 6 INCHES (152 MM). THE APPROVED MATERIAL SHALL BE CONTINUOUS TO THE TOP OF WALLS AND �2 • �w ®® TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED IN SECTION R703.1., ®�,� °••••®•••• e� ii� ®II Al 19 Bp! R703.8 FLASHING APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING 0 COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT 0 COMPLYING WITH AAMA 800 OR ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, ASTM C 1281, AAMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND V) TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING OR OTHER APPROVED METHOD: 1.1 THE FENESTRATION MANUFACTURERS INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER'S, IN ACCORDANCE WITH THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE 0 SILL OF EXTERIOR WINDOWS AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE 5m BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL ALSO INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES. 00 1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL. 00 1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS. r*% 0 1.4 IN ACCORDANCE WITH FMA/AAMA 100 FMA/AAMA 200 FMA/WDMA 250„ OR FMA/AAMA/WDMA 300. �■.� 1 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH >m PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 0 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. J 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME 1989 CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. 7. AT BUILT-IN GUTTERS. FLASHING DETAILS N16, DAVIS BEWS DESIGN GPOVP 150 STATE STREET EAST OLDWAK FLORMA 34677 813.925.1300 TEL: 813.925.1800 FAX WWW.DAVISBEWS.COM TAMPA • DENV R- EST. 1994� • TITLE • FLASHING DETAILS • SHEET • 5HEATHING TEXTURE FIN15H COAT BROWN COAT 5CRATCH COAT SELF -FURRING LATH TWO LAYERS WRB WEEP SCREED TERMINATE 5ELF ADHE5IVE FLASHING AT LOWER N05E OF M.W.W.5. 5ELF ADHESIVE FLASHING MASONRY BLOCK WALL WEEP SCREED AT MID —WALL MASONRY TO WOOD DETAIL EXTERIOR SHEATHING REFER TO TECHNICAL-- / LETTER ON CHEMICAL / COMPATIBILITY SELF -ADHERED FLASHING DO NOT FLASH OVER BOTTOM NAILING FLANGE SELF —ADHERED FLASHING HALF ROUND WINDOW WALL SHEATHING ASPHALT SEALANT: EXTEND MIN. OF 6" OUTSIDE OF FLASHING 6 DIVERTER FLASHING MiV6„ DRIP EDGE FASCIA — NAILING FLANGE N-, ESISTIVE WOOD FRAME CONSTR SELF-ADHERED FLASHI BY LAPPING DOWN OVER RIM JOIST AND U WALL BY 6 IN. SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) �,— DOOR ROUGH OPENING - 3/4"-l"BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SELF -ADHERED FLASHING SUBFLOOR RIM JOIST SELF —ADHERED FLASHING EXTERIOR DOOR WITH DECK — SECTION A EXTERIOR - 3/4"-l" BEAD OF CONSTR. SHEATHING ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SECTION -A (SEE DETAIL WP02) -- SELF -ADHERED FLASHING FIGURE 1: FLASHING INSTALLATION SELF -ADHERED FLASHING SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) LL__:iL__ WINDOW UNIT SLOPE 0.3 in: 12.0 in (0.6 cm : 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT. FIN. BUILDING PAPER 111111'11- 1 A TI I SELF —ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT - INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE FLASHING JAMB & HEAD THROUGH SELF -ADHERED FLASHING, SEE FLASHING — SELF -ADHERED FLASHING FLANGED WINDOW �a (SEE DETAIL WP01) ' SCORED RELEASE PAPER SELF -ADHERED FLASHING, (BEFORE FOLDING, SCORE EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE VERTICALLY FROM BOTTOM OF ADHESIVE AS SHOWN) THRESHOLD U O *INSTALL SELF -ADHERED FLASHING IN ORDER AS SHOWN BY NUMBERS ** INSTALL FLASHING AND WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS SELF —ADHERED FLASHING EXTERIOR DOOR WITH DECK CONT. GALV. "L" FLASHING PER 611EXTURED, PAINTED MANUFACTURES XTER. WALL FINISH SPECIFICATIONS ROOF CRICKET: MIN: 3:12 SLOPE PLASTER STOP -- CRICKET AS (REQUIRED AT SPECIFIED ALL LEVEL VALLEY VERTICAL WALL BEAUTY STRIP RC BY PLAN LOCATIONS) AT ENTRY SHINGLE OVER FLASHING W/ TAR CONT. GALV. "L" - FLASHING PER MANUFACTURES SPECIFICATIONS ' \ OVER ROOF ROOF MATERIAL PER ' SHINGLES W/ TAR ELEVATIONS WITH APPROVED NOTE: THIS DETAIL IS REQUIRED UNDERLAYMENT (REFER TO AT ALL VERTICAL WALL INTERSECTIONS COVER SHEET) WITH ROOF VALLEYS & ROOF CRICKETS. ,,. PRE-ENGINEERED ROOF TRUSSES AT 24" O.C. _ BEAUTY STRIP ROOF Iz SHINGLE OVER TEXTURED, PAINTED EXTERIOR WALL FINISH�< HOLD EXTERIOR FINISH 2" ABOVE ROOF FLASHING " CAULKING FIGURE 2: WALL FINISH ASPHALT SEALANT: EXTEND MIN. 6" ABOVE FLASHING - _.-,-. 6TO12" PER PLAN 6" HIGH SPECS. : ` � DIVERTER 6 FLASHING GALV. V FLASHING TYPICAL. ROOFING FELT -DRIP EDGE FASCIA FIGURE 3: CORNER DETAIL SELF -ADHERED FLASHING INSIDE CORNER ASPHALT BASED SEALANT APPLIED BEHIND FLASHING AND EXTENDING A MINIMUM OF 6" ABOVE VERTICAL RISE OF FLASHING AT KNEEWALL SEALANT HIND DETAILS FLASHING W/ TAR FLASHING INSTALLATION �CONT. GALV. "L" WHERE ROOF MEETS VERTICAL WALL FLASHING PER / MANUFACTURES SPECIFICATIONS OVER ROOF SHINGLES W/ TAR /--- SHINGLE PER �E CONTRACT RHO TYPICAL ROOF TO WALL FLASHING DETAIL LINE VALLEY BY CENTERING 36" WIDE CERTAINTEED WINTERGUARD WATERPROOFING SHINGLE UNDERLAYMENT OR EQUIVALENT �i DIRECTLY TO DECK. DO NOT W VALLEY CE FIGURE 4: VALLEY DETAIL F,o& O� Tti��gsy�ti c <�q Tq0 0ti� SS0 gRFq�Oij,ob 9T O RAKE METAL DRIP EDGE TO BE OVER / UNDERLAYMENT AT I/ GABLE ENDS EMBED EACH SHINGLE IN A 2" WIDE STRIP OF ASPHALT RAGING CEMENT. CUT 2" DIAGONALLY OFF UPPER CORNER OF TRIMMED SHINGLE CUT SHINGLES 2" BACK FROM VALLEY CENTERLINE METAL DRIP EDGE TO BE UNDER UNDERLAYMENT AT ROOF EAVES „.) ROOF OEGK 2 s O UNO�R�PyM\ 4 ENO\,w C O JRg(c SRO G NO GO�RS� \ OU�cS� z 5 - 28'� - --EAVES 14" ', FIRST STARTER SHINGLE SAVE 7" PIECES TO USE IN 5TH COURSE EXTEND THE SHINGLES OVER THE RAKE AND EAVES ABOUT 1/2" IF DRIP EDGE IS USED, OR ABOUT 3/4" IF NO DRIP EDGE IS USED. 7/8" CEMENT PLASTER 7/8" CEMENT PLASTER IN IN ACCORDANCE WITH ACCORDANCE WITH ASTMC926 ASTMC926 - APPROVED WEATHER -RESISTANT APPROVED WEATHER -RESISTANT MATERIAL W/ METAL LATH IN MATERIAL W/ METAL LATH IN ACCORDANCE WITH ASTMC1063 ACCORDANCE WITH ASTMC1063 / BUILDING PAPER BUILDING PAPER 5)5<' 7/1611 O.S.B. 7/16" O.S.B. SHEATHING \ SHEATHING , KEEP TOP EDGE OF WEEP METAL SCREED 2" BELOW TOP OF !' FLASHING BLOCK 31 /2" UNPERFORATED VULCUM CAULK BOTTOM FLANGE 7/8" JOINT ONLY WEEP SCREED MAINTAIN METAL FLASHING 3-1/2" BOTTOM OF UNPERFORATED FLANGE 7/8" WEEP SCREED WEEP SCREED r 1 1 /2" TO 2" ABOVE ROOF 1/2" CEMENTITIOUS SHEATHING DECORATIVE FINISH ALL INSIDE AND OUTSIDE CORNER WILL NEED TO BE MITER CUT AND • CAULKED ALL BUTT CEMENT PLASTER IN ACCORDANCE WITH JOINTS NEED TO BE EMBEDDED IN ASTMC926 OVER WOOD m ���®®� °� 2ND FLOOR SEALANT USING VULCUM CAULK FOR ALL 1/2" CEMENT PLASTER FINISH 2 1/2" PERFORATED CEMENT BLOCK FLANGE 1/2" WEEP �- m�m�°� SCREED K C UolQ 0Lo 0 O _j 1 CO�M N om W 1 L. > �JN M o Lo ` • ca c 00 NN ... 0 _ C 0 4 E lL ��N � 0g ro� �. 0c z ct, LLI a:cm M - co ac- PLASTER"��•v®® a Z OVER :.� l J ( o,� La . CL sLOOR LOCK 1ST �' 1.'1 j -� ,. CL LL 1 l INSTALL BOTTOM EDGE OF ` SLAB WEEP SCREED 1" BELOW �® o®®®° ®•oo®��a®� FINISH FLOOR ®': ��o•o•®!(� oo•o �1� s uj co ® Q <C o / 46 ®® � OPTIONAL DETAIL V .� '�•••0 •°���`.®`® NOTE. /� �® THE BUILDING PAPER AND METAL LATH MUST BE INSTALLED OVER THE TOP OF THE WEEP SCREED. *INSTALL FLASHING AND WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS SELF -ADHERED FLASHING DECK JOIST r DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDWW R ORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TAMPA • DENVER- r EST. 1994- WEEP SCREED DETAIL SCALE: NOT TO SCALE 0 )UBLE JOIST AM BELOW SELF -ADHERED FI THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL FLASHING AND FLASHING DETAILS WATERPROOFING METHODS TO BE USED. W.P. li GF.I A/C DISCONN. HORIX.— MAKE-UP LIGHTS HORIX.— MAKE-UP LIGHTS WALL W.P. MNT, COACH LIGHT _� COACH LIGHT W.P. GF.I. FOR T.U.G. SERVICE L C I fRICAL E"� DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER .P. WEATHERPROOF DUPLEX OUTLE1 .F.�. GROUND FAULT INTERRUPTER DUPLEX OUTLET �$ HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH 13 THREE-WAY SWITCH 14 FOUR-WAY SWITCH ID DIMMER SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE t P.C. LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT E FLUORESCENT LIGHT FIXTURE 4 EXHAUST FAN ;Q, EXHAUST FAN/LIGHT COMBINATION ®D ELECTRIC DOOR OPERATOR (OPTIONAL) cH CHIMES (OPTIONAL) 0 PUSHBUTTON SWITCH (OPTIONAL) © CAR50N MONOXIDE DETECTOR sp SMOKE DETECTOR so SMOKE / CARBON MONO. COMBO DETECTOR Q TELEPHONE (OPTIONAL) TELEVISION (OPTIONAL) 0 THERMOSTAT pi ELECTRIC METER Aw ELECTRIC PANEL DISCONNECT SWITCH t� SPEAKER (OPTIONAL) cC� ROUGH -IN FOR OPT. CEILING FAN v J c� CEILING MOUNTED INCANDESCENT LIGHT FIXTURE W/ G J ROUGH -IN FOR OPT. CEILING FAN NOTES 1. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTE PIERS (GRI.) A$ INDICATED ON PLANS OR AS ITEM NO.4 AND 5 BELOW INDICATES. 2, UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISHED FLOOR: SWITCHES.... 42" OUTLET$ ....14" TELEPHONE ... 14" (UNLESS ABV COUNTERTOP) TELEVI5I0N...14" 3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS: 4. ALL 15A AND 20A RECEPTACLES IN SLEEPING ROOMS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR AREAS WILL REQUIRE A COMBINATION TYPE A.F.C.I. DEVICE AND TAMPER -PROOF RECEPTACLES PER KE.C. 2011406.12 AND 406.13 5, ALL 15A AND 20A 120V RECEPTACLES LOCATED IN THE GARAGE AND UTILITY ROOMS SHALL BE GF.C.I. PROTECTED (GF.I ). 6. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO ENSURE THAT ALL ELECTRICAL WORK 15 IN FULL COMPLIANCE WITH NF.PA,10, N.E.C. 2011, F.B.C.R 5TH EDITION (2014), AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES, 1. EVERY BUILDING HAVING A FO561L-FUEL-5URNING HEATER OR APPLIANCE, FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL CARBON MONOXIDE DETECTOR INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES. 6. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACKUP. COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED OR LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. 4/0 ALU. CABLE MAIN DISCONNECT METER COM50 - SQUARED A/C DISC. TYP. 14 AND'12 COPPER TO REFER TO FLOOR INSIDE LIGHTS AND OUTLETS PLAN FOR NOTED MAIN DISC. PANEL AMPS. REQUIRED 10 COPPER TO WATER HEATER UNDERGROUND 06 COPPER TO RANGE • • K ro C ro oJ JOLoO co U) i. >.�JM 66 0� o. 00 2 Uti1, rrA 6''zl o C O �E d .c J 00 ON 600 •.■ T z N � oe wwwrwrwww�rwwi • JOB NUMBER 27002.157 CAD FILE NAME LOT 288 ISSUED 03-23-17 REVISED Y DAMS BEWS DESIGN GROVP 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813 925 1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.GGM TAN4PA • DENVER � EST. 1994 CD qqm O 0 cn O z cn oc pmmq o� =o � °C N0 SERVICE BY POWER COMPANY $4 COPPER TO 5/8"GROUND ROD ALSO SERVICE TO BE BONDED" TO FOOTING STEEL 1989 ELECTRICAL RISER DIAGRAM NOTE: ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS OF THE NATIONAL ELEC. CODE, LOCAL CODES, AND THE LOCAL POWER COMPANY. MAIN FLOORELECTRICAL PLAN GARAGE RIGHT • TITLE • MAIN FLOOR ELECTRICAL PLAN • SHEET • 4A WORIZ. MAKE-UP LIGHTS G.G. VERIFY ALL SMOKE DETECTORS TO BE HARD -WIRED � DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER �w.P. WEATHERPROOF DUPLEX OUTLET OI.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET � HALF-SWITCWEp DUPLEX OUTLET � SPECIAL PURPOSE OUTLET � DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH _t3 THREE-WAY SWITCH 14 FOUR-WAY SWITCH ID DIMMER SWITCH -�- CEILING MOUNTED INCANDESCENT LIGHT FIXTURE �-�- WALL MOUNTED INCANDESCENT LIGHT FIXTURE iC7RECESSED INCANDESCENT LIGHT FIXTURE Ac. LIGHT FIXTURE WITH PULL CHAIN � TRACK LIGHT FLUORESCENT LIGHT FIXTURE C� EXHAUST FAN EXHAUST FAN/LIGHT COMBINATION � ELECTRIC a00R OPERATOR (OPTIONAL) ® CHIMES (OPTIONAL) o PUSHBUTTON SWITCH (OPTIONAL) © CARBON MONOXIDE DETECTOR so SMOKE DETECTOR so SMOKE /CARBON MONO. COMBO DETECTOR � TELEPHONE (OPTIONAL) My TELEVISION (OPTIONAL) (D iNERh105TAt ELECTRIC METER _ ELECTRIC PANEL —� DISCONNECT SWITCH ® SPEAKER (OPTIONAL) c�7 ROUGH -IN FOR OPT. CEILING FAN v J c/� CEILING MOUNTED INCANDESCENT LIGHT FIXTURE W/ G J ROUGH -IN FOR OPT. CEILING FAN NOTES - I. PROVIDE AND INSTALL GROUND FAULT CIRCUIT- INTERRUPTERS AS INDICATED ON PLANS OR AS ITEM NO. 4 AND 5 BELOW INDICATES. 2. UNLESS OtWERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISHED FLOOR: SWITCHES.... 42" OUTLEtS..... 14° TELEPHONE ... l4" (UNLESS ABv COUNTERTOP) tELEVISION...l4° 3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS. 4: ALL 15A AND 20A RECEPTACLES IN SLEEPING ROOMS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUNROOMB, RECITATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR AREAS WILL REQUIRE A COMBINATION TYPE AF.C.I. DEVICE AND TAMPER -PROOF RECEPTACLES PER N.E.G: 20II 4(D6.12 AND 406.13 5. ALL 15A AND 20A 120V RECEPTACLES LOCATED IN THE GARAGE AND UTILITY ROOMS SHALL BE PROTECTED 6, IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN 1'0 ENSURE TWAT ALL ELECTRICAL WORK IS IN FULL COMPLIANCE WITH N.F.P.A.1m, N.E.G. 2011, F.B.G.R. - 5TN EDITION (2014), AND .ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES. 1. EVERY BUILDING WAVING A F0581L-FUEL-BURNING HEALER OR APPLIANCE, FIREPLACE, OR AN ATTACHED GARAGE SWALL HAVE AN OPERATIONAL CARBON MONOXIDE DETECTOR INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES. 8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL POWER UTILITY. SUCH ALAF2h16 SWALL HAVE BATTERY BACKUP. COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED OR LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. UPPER FLOOR ELECTRICAL PLAN GARAGE RIGHT4B x �r r '0 i� JO�O 0O Jm(\� OiL IA V/ 2o�co em W . , > >jN 0 0 � 5-h /rr 0 -� C O LL C4 a 0 � 1p 000 (�ti L45 off M JOB NUMBER 27002.157 • CAD FILE NAME LOT 288 ISSUED 03-23-17. REVISED 9I BEWS DAVISD1iVIS BEWS. DESIGN GROVP 150 STATE STREET EAST OLDSMAR, FLORIDA 346'77 813. 925.1300 TEL. 813.925.1800 FAX W W W.DAVISBEWS.COM TAMPA • TJENVER. EST.1494 r.. r.. l.l • TITLE • UPPER FLOOR ELECTRICAL PLAN • SHEET • GENERAL NOTES FOUNDATIONS SOIL UNDER SLABS AND UNDER FOOTINGS TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM- 1557 (MODIFIED PROCTOR) MINIMUM BEARING CAPACITY 2000 PSF TERMITE TREATMENT THE SOIL UNDER THIS STRUCTURE SHALL BE TREATED FOR THE PREVENTION OF SUBTERRANEAN TERMITES, OR A PERIMITER TREATMENT (BORACARE) MAY BE USED, IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. CAST IN PLACE CONCRETE 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI, A SLUMP OF 4" PLUS OR MINUS 1", AND HAVE 2 TO 4% AIR ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.58. 2. ALL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 40. 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 FOR 6x6xW1.4xW1.4 WWF SHALL BE LAPPED AT LEAST 6" & CONTAIN AT LEAST ONE CROSS WIRE WITHIN THE 6".FIBERMIX OF EQUAL SPECIFICATIONS MAY BE USED IN LIEU OF WWF. 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS," ACI 301. 5. HORIZONTAL FOOTING BARS SHALL BE BENT MIN. 12 BAR DIAMETERS (EXCLUDING BEND) AROUND CORNERS OR CORNER BARS WITH MIN. 24" LAP EXCLUDING BEND AT EACH END SHALL BE PROVIDED. 6. MINIMUM LAP SPLICES ON ALL REINFORCING BARS SHALL BE 48 BAR DIAMETERS. 7. SLAB ON GRADE, REINFORCEMENT SHALL BE SUPPORTED IN PLACE FROM THE CENTER TO UPPER 1/3 OF THE SLAB. BOLTS AND THREADED RODS 1. ALL BOLTS & THREADED RODS TO BE ASTM A307 OR BETTER (U.N.O.) 2. STEEL BOLTS LESS THAN ONE -HALF -INCH (12.7 mm) IN DIAMETER USED AS FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER, FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153, 3. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC -COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55, MINIMUM. MASONRY WALL CONSTRUCTION 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, W/ A MINIMUM NET COMPRESSIVE STRENGTH OF 2000 PSI (fm = 1900 PSI) 2. MORTAR SHALL BE TYPE M OR S, CONFORMING TO ASTM C270 3. HEAD MORTAR JOINTS AT PRECAST WINDOW SILLS TO BE NO MORE THAN 111 . 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. 5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS FILLED WITH COARSE GROUT AND GRADE 40 STEEL. REINFORCEMENT SHALL BE PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2" CLEARANCE TO INSIDE FACE. 6. VERTICAL REINFORCEMENT SHALL BE HELD IN CENTER OF THE MASONRY/ BLOCK WALL AT THE TOP & BOTTOM & MAXIMUM 8'-0" U.N.O. VERITCALLY. TIES TO THE FOOTING & LINTEL STEEL IS ADEQUATE @ TOP & BOTTOM OF WALL; REBAR POSITIONERS IN MIDDLE OF WALL 7. REINFORCING STEEL SHALL BE LAPPED MIN. 25" U.N.O. 8. HOOKS AT THE TOP & BOTTOM OF VERTICAL REINFORCING BARS TO BOND COURSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND 9. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. 10. MASONRY ROUGH OPENING TOLERANCES - 1/4" TO + 1/2" 11. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF GROUT INTO CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 13, DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318, LATEST EDITION 5.11.1 14. DURING CONCRETE POURS, GC TO ADEQUATELY VIBRATE THE FILLED CELL W/ EITHER RODDING OR PENCIL VIBRATOR TO ENSURE PROPER CONCRETE CONSOLIDATION. WOOD CONSTRUCTION 1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", LATEST EDITION.(NDS) 2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS. SHEAR WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS. (I.E. BLOCKING OR GABLE END BRACING), SHALL BE SPRUCE- PINE -FIR OR EQUIVALENT NO 2 GRADE SHALL BE USED METAL COATINGS FOR USE WITH PRESSURE TREA I EU WUUU IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT ALL METAL CONNECTORS, METAL FASTENERS, ANCHORS, AND NAILS ARE THE APPROPRIATE MATERIAL AND/OR HAVE THE APPROPRIATE COATING FOR USE WITH THE DIFFERENT TYPES OF PRESSURE TREATED WOODS, AS PER THE FOLLOWING GUIDELINES. 1. WOOD TREATED WITH DOT SODIUM BORATE(SBX): CONNECTORS SHALL BE A MINIMUM G50 ZINC COATING 2. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE (NON -DOT) TREATMENTS: CONNECTORS SHALL BE A MINIMUM G185 ZINC COATING. 3. FOR ALL OTHER COMBINATIONS FOLLOW THE RECOMMENDATIONS OF THE PRESERVATIVE WOOD TREATER. 4. STAINLESS STEEL CONNECTORS AND FASTENERS MAYBE USED WITH ALL TYPES OF PRESSURE TREATED WOOD. PREFABRICATED WOOD TRUSSES 1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS.UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR LATERAL FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE COORDINATE WITH THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS AND STRUCTURAL PLANS FOR MORE INFO. 2. TRUSSES SHALL BE DESIGNED BY MWFRS METHODOLOGY FOR LONG SPAN TRUSSES TO DETERMINE UPLIFT AND REACTION VALUES. MEMBER AND PLATE DESIGN TO BE CALCULATED BY COMPONENTS AND CLADDING METHOD UNLESS SPECIFIED OTHERWISE BY TRUSS ENGINEER OF RECORD 3. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI TPI 1. 4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQUIRED BY TRUSS MANUFACTURER UNLESS NOTED ON PLANS 5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF TRUSSES ONLY: WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY TRUSS MANUFACTURER IN ACCORDANCE WITH THE DESIGN LOADS. TRUSS DESIGN LOADS: TOP CHORD: Lr = 16 PSF DL = 7 PSF (SHINGLE TYPE ROOF COVER) DL = 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) DL = 14 PSF (TRUSS OVERBUILD) BOTTOM CHORD: DL = 5 PSF MINIMUM FLOOR DESIGN LIVE LOADS: A) FLOORS = 40 PSF B) BALCONIES = 60 PSF / 100 PSF (IF BALCONY > 100 SQ FT) C) DECKS = 40 PSF D) STAIRS = 40 PSF E) BONUS ROOM/GAME ROOMS = 60 PSF U.N.O. MINIMUM FLOOR DESIGN DEAD LOADS: A) FLOORS = 15 PSF B)BALCONIES = 15 PSF GENERAL LOADING: ATTIC WITHOUT STORAGE = 10 PSF ATTIC WITH LIMITED STORAGE = 20 PSF GUARDRAILS / HANDRAILS = 200 LB POINT LOAD / 50 PSF GUARDRAILS IN -FILL COMPONENTS = 50 PSF GENERAL TRUSS BRACING & BLOCKING REQUIREMENTS -ADDIT'L BRACING & BLOCKING PER BCSI-1 & TRUSS MANUFACTURER'S DWGS -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA RECOMMENDATIONS FOR MIN. 7/16" OSB SHEATHING -MIN 2x SYP #2 BLOCKING REQ'D ALONGSIDE TRUSS TOP CHORD @ ROOF HIP/RIDGE TO PREVENT SHEATHING SPAN FROM EXCEEDING 2FT (NOT REQ'D IF SHEATHING SPAN IS LESS THAN 2FT). BLOCKING TO TRUSS TOP CHORD w/ (2) 12d NAILS @ 12" O.C. MAX & 4" FROM EA. END. NOTE: PLYWOOD EDGES @ HIP CORNERS REQUIRE MIN 2x4 SYP #2 BLOCKING w/ (3) 12d TOENAILS EACH END. -TRUSS "X" BRACING: MIN 2x4 SYP #2 AT ANGLE APPROX. 45' FROM VERT. TO EA. TRUSS MEMBER w/ (3) 12d NAILS. SPACE "X" BRACING ALONG TRUSS SPAN @ 10'-0" MAX AND EQUALLY SPACED FROM END OF TRUSS. "X" BRACING TO START 20'-0" MAX FROM #1 HIP GIRDER AND / OR (4) BAYS AFTER GABLE END BRACING. SEE BCSI-B3 SECTIONS 1, 2 AND 3 FOR ADDITIONAL ROOF PLANE PERMANENT BRACING REQUIREMENTS. -PERMANENT 2x4 SPF #2 (MIN.) CONT. LATERAL TRUSS BOTTOM CHORD BRACING PERPENDICULAR TO TRUSS SPAN AT 164' O.C. MAX W/IN TRUSS SPAN OR PER TRUSS DESIGN DRAWINGS. ATTACH W/ (2) 16d NAILS AT EACH TRUSS. OVERLAP BRACING AT LEAST ONE TRUSS SPACE (24") PLUS 6" MIN PAST BOTTOM CHORD. -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRACE (CLB) ACROSS TRUSS WEBS AS INDICATED ON TRUSS SHOP DRAWINGS & BCSI-B3. ("T" BRACING MAY BE USED I.L.O. PEMANENT CLB IF IT EXTENDS MIN. 90% OF THE TRUSS WEB (SEE WEB REINFORCEMENT TABLE WITHIN BCSI-B3). -AT RAISED HEEL TRUSSES, 2x4 SYP #2 (MIN.) AT TOP AND BOTTOM OF HEEL W/ (2) 12d TOENAILS REQ'D. EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND INDICATED BLOCKING. ALTERNATE IF HEEL HEIGHT IS LESS THAN 12" TALL: 2x4 SYP #2 BEHIND THE TRUSS VERT. RUNNING FROM TOP TO BOTTOM ACROSS MAX 4 TRUSSES, THEN BOTTOM TO TOP W/ (2) 12d NAILS AT EACH TRUSS MEMBER (DIAGONAL BRACING) DIAGONAL BRACING REQUIRED AT CLB PER BCSI-B3. 6. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS, WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. FIELD REPAIR NOTES REGARDLESS OF SPECIES U.N.O. ON FRAMING PLANS OR DETAILS, END -JOINTED 1. OMITTED REBAR LUMBER IS NOT PERMITTED TO BE USED IN ANY LOAD BEARING (GRAVITY OR WIND) DRILL A 3/4" 0 HOLE MIN. 6" DEEP AT LOCATION OF OMITTED REBAR, AND INSTALL#5 BAR CONDITIONS. E.O.R. TO REVIEW IF INSTALLED. INTO EPDXY FILLED HOLE. EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQ. FOLLOW 3. FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED MANU'S INSTRUCTIONS. ASSURE ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. FROM HOLE w/ COMPRESSED AIR PRIOR TO APPLYING EPDXY. ALLOW EPDXY TO CURE TO 4. THE PORTIONS OF GLUED -LAMINATED TIMBERS THAT FORM THE STRUCTURAL MANU'S SPECIFICATIONS, THEN FILL CELL IN NORMAL WAY DURING BONDBEAM POUR. USE SUPPORTS OF A BUILDING OR OTHER STRUCTURE AND ARE EXPOSED TO WEATHER 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN. 12 BAR DIAMETERS(EXCLUDING AND NOT PROPERLY PROTECTED BY A ROOF, EAVE OR SIMILAR COVERING SHALL BEND). BE PRESSURE TREATED WITH PRESERVATIVE, OR BE MANUFACTURED FROM 2. STRAPS/CONNECTOR SUBSTITUTION NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD, MAY SUB STRAPS/CONNECTORS w/ STRAPS/CONNECTORS OF EQUAL OR GREATER UPLIFT 5. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY & LATERAL RESISTANCE VALUES IN FIELD WITHOUT VERIFICATION, PROVIDED ALL (MOISTURE CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND FIRE SAFETY MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED. SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE 3. STAIR CONSTRUCTION DESIGNED AND DETAILED BY OTHERS. 2X12'S MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS. RIM BOARDS MAY BE 6. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE USED FOR RISERS & TREADS ILO 2x12'S (SEE GEN. STAIR DIETS FOR ADDIT'L INFO.) CENTER OF THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION SHEILDS. ALL 4. METAL STUD SUBSTITUTION HOLES OVER 1" IN DIA FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH WOOD STUDS MAY BE SUBBED w/ METAL STUDS IN NON -LOAD BEARING WALLS SIMPSON HSS2 STUD SHOES, TYP U.N.O. 7. MANY OF THE PRESSURE TREATED WOODS USE CHEMICALS THAT ARE 5. OMITTED J-BOLT -1/2" ALL THREAD ROD w/ 2" x 2" SQ. WASHER DRILL & EPDXY w/ SIMPSON SET EPDXY WITH CORROSIVE TO STEEL. IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY THE TYPE MIN. 7" EMBEDMENT. SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST -1/2"x6" CORROSION. FOR EXAMPLE. ACQ-C, ACQ-D, CBA-A OR CA-B REQUIRE HOT -DIPPED J-BOLT. TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS GALVANIZED OR STAINLESS STEEL FASTENERS. DOR SODIUM BORATE (SBX) DOES 6, MORTAR JOINTS -FOR BED JOINTS 1/2"-1", GROUT FILL CELLS IN BLOCK AFFECTED (NO VERT. REINF. REQ'D) NOT. 8. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH, CONCRETE OR -FOR HEAD JOINTS GREATER THAN 3/4", GROUT FILL CELL IN BLOCK AFFECTED ON MASONRY IS TO BE PRESSURE TREATED. EA.SIDE OF JOINT. PROVIDE (1) #5 VERT. REINF. IN EA. CELL CONT. PER PLAN. 9. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR "EXCEPTION: IF TIE BEAM COURSE AND ADJ. TWO COURSES BELOW, AS WELL AS 1st (2) MASONRY. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT COURSES FROM FND. HAVE HEAD JOINTS WHICH FALL W/IN THE SPECIFIED TOLERANCES, WOODEN TOP PLATES. THE ADDED VERTICAL REINFORCEMENT IS NOT REQ'D TO BE EPDXIED INTO TIE BEAM/FTG 10. SEE PLAN FOR BUILT UP STUD COLUMN AND BEAM NAILING PATTERNS -FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE (1) #5 ENGINEERED LUMBER VERT. REINF. IN EA. CELL, CONT. PER PLAN. ALL ENGINEERED LUMBER IS TO HAVE THE MINIMUM DESIGN 7. OVERHANGING CMU WALL -FOR CMU OVERHANGING FOUNDATION <1/2", NO FIX IS REQ'D POUR TIEBEAM & VERT. VALUES AS FOLLOWS: CELLS PER PLAN. COLUMN S BEAMS STUD -FOR CMU OVERHANGING FOUNDATION FROM +1/2"-1-1/8", GROUT FILL FIRST (3) COURSES E = 1,800Win U.N.O. E = 2,000,000 Win U.N.O. E = 1,500,000 Ib/in2U.N.O. IN WALL ALONG AREA AFFECTED & TIE BEAM AND VERTICAL CELLS PER PLAN Fb = 2500 Fb = 3000 Fb = 2200 -'FOR CMU OVERHANGING FOUNDATION OVER 1-1/8", CONTACT FOR FOR REPAIRS. Ft = 1500 Ft = 1700 Ft = 1500 STRUCTURAL STEEL 1. MATERIAL SPECS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 36, Fy=36 KSI. TUBE Fc 11= 3000 Fc 11= 3000 Fc 11= 2100 STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI. PIPE STEEL: ASTM A53, TYPE E OR S, Fy = Fc 1= 900 Fc 1= 900 Fc 1= 450 35 KSI. ALL OTHER STRUCTURAL & MISC. STEEL: A36 Fy=36 KSI. Fv = 285 Fv = 285 Fv = 150 2. STRUCT. CONNECTIONS: ALL STRUCT, BOLTS TO BE A325N U.N.O. ALL A325N BOLTS WOOD BEARING SURFACES ARE TO BE SYP#2 OR BETTER END GRAIN SHALL BE AT "SNUG -TIGHT" CONDITION AS DEFINED IN THE SPEC. SLIP CRITICAL (SC) BOLTS MUST BE FULLY TENSIONED PER SPEC STRUCT. BOLTS SMALLER THAN 5/8" DIA. CONDITION U.N.O. TO BE A307 THREADED ROD & CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CEILING CONSTRUCTION CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 1. USE 1/2" CEILING OR SAG RESISTANT BOARD FOR 24" O.C. FRAMING UNLESS SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINF.T SHOP DWGS TO BE PROVIDED TO FOR BEFORE FABRICATION FOR REVIEW AND APPROVAL. WELDED OTHERWISE SPECIFIED, 2. 5/8" TYPE "X" GYPSUM BOARD SHALL BE USED ON CEILING IN GARAGE WHEN CONNECTIONS: ELECTRODES - E70XX UNO (LOW HYDROGEN). FILLET WELDS SHALL BE SPACE IS ABOVE THE GARAGE. 3/6" UNO, LIVING TION DETAILS INC PROFILES J. SUBMIT SHOP DWGS INDICATING ALL SHOP AND EREC SIZES, SPACING, & LOCATIONS OF STRUCTURAL MEMBERS, CONNECTION ATTACHMENTS, FASTENERS, LOAD, AND TOLERANCES. 4. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY UNDER STAIR PROTECTION ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE SPRAY -ON FIRE PROTECTION. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD DESIGN PRESSURES WIND DESIGN LOAD INFORMATION WIND SPEED (ULTIMATE) 139 mph WIND SPEED (ALLOWABLE) 108 mph WIND EXPOSURE B RISK CATEGORY 11 BUILDING TYPE V B ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 WIND PRESSURE & SUCTION EFFECTIVE (PSF) WIND H VALUE DENOTES PRESSURE AREA (SQ FT) - VALUE DENOTES SUCTION AREA 4E O (+) 21.2 (+) 21.2 10 -) 22.9 (- 28.3 (+) 20.2 (+) 20.2 20 (_) 22.0 (-) 26.4 (+) 19.0 (+) 19.0 50 (-) 20.8 (-) 23.9 (+) 18.0 (+) 1`8.0 100 (-) 19.8 - 22.0 GARAGE DOORS 9'-0" x 7'-0" 16-0" x T-0" (+) 18.4 (+) 17.7 (-) 20.9 (-) 19.7 WIND PRESSURE/ SUCTION DIAGRAM 5 5 4 4 aI 5 5 �✓' a STANDARD DESIGN PRESSURE NOTES 1. ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS PER FLORIDA BUILDING CODE 5th EDITION (2014). WIND SPEED IS BASED ON LINEAR INTERPOLATION FOR THIS SITE. 2. MEAN ROOF HEIGHT FOR A TYPICAL SINGLE STORY HOME IS 15FT, 2 STORY HOME IS 30FT 3. MULTIPLY THE ABOVE PRESSURES BY 1.67 TO GET ULTIMATE WIND PRESSURES. 4. "a" = END ZONE IS ONLY W/IN 5'-0" OF ALL EXTERIOR BUILDING CORNERS. 5, INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREAS. 6. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR GREATER IS CONSIDERED TO BE IN THE WIND -BOURNE DEBRIS AREA. OPENING PROTECTION REQUIRED. REFER TO SECTION R301.2.1.2 OF THE RESIDENTIAL CODE FOR SPECIFICATION REQUIREMENTS OF THE USE OF WOOD STRUCTURAL PANELS. REFER TO TABLE R301.2.1.2 FOR ATTACHMENT SPECIFICATIONS SHEET SHEET TITLE o co S1 STRUCTURAL NOTES S2 S3 S4 S4.1 S4.2 S5 SD1 SD2 SD3 S D4 SD5 SD6 ST1 NUMBER 1 2 FOUNDATION PLAN N DOWEL PLACEMENT PLAN O z 00 FIRST FLOOR FRAMING PLAN NOTES & CONNECTOR LEGEND w � 00 ROOF FRAMING PLAN Z w LINTEL PLAN 5 FOUNDATION DETAILS Q GENERAL DETAILS o i GENERAL DETAILS w > W GENERAL DETAILS o TWO STORY DETAILS o �a91U9f, w TWO STORY DETAILS o ®,, ®.w®��m����,,00 STAIR DETAILS Pw ' = z oW= UPDATES w Z C Q • �, 0 DATE DESCRIPTION ? '�,®®®®I ,'' 'R®`®®®®® m U_ /2014 CREATED ELEV. A,B & C, A w/LANAI & BONUS 5/8 OPTIONS APPLIED TRUSSWAY TRUSSES TO ELEV B W/EXT o o 4/13/2015 LANAI U Q W* O F- z IL O c Q a U_, LL- .�''�i1i,i" U . U O � � CIL w W _ U :D � V, ( ^ U) W 0 Z � O co Urtrod -o� WJM�,� o Z Q 'OwrNj� E O 06 wZcn�0) � F- r- Q � (� QO�uj�:� z U H p 0 00 U Q0 W z 10 5,5 -j LU J cACxZo Z) QOOind o zh -�wui _ Z < =) () Z Z E O S U z w J V D O�Qa O W N J O wNQ O <c w W W Z w_ = rn O Z 0 Q O Q 0 Z Z 3: 0 W I'- 00 11 Q N F- LL1 < z0 0WJ _ H 0) 00 O C>CCD0 O 1 F_ O r W �Z0 O Z L W >- W O -- 7 F- a. II- ry U 11. F- C0 STRUCTURAL ENG: RMG Q DRAFTING: Z -STRUCT: JV w p QC CHECK: CC ry JOB No. TM - 21701.94 SCALE: AS INDICATED DATE: 04/12/2017 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR 5. SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2-INCH INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECS (IF PROVIDED). (12.7MM) GYPSUM BOARD. SUBMIT REPORTS TO ARCHITECT AND ENGINEER. COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. 30'-0" 2-STORY FTG. 0 FOUNDATION NOTES: w 1. PROVIDE MIN. 6 MIL. APPROVED VAPOR BARRIER. ALL JOINTS TO BE Q LAPPED MIN. 6" AND SEALED. Z Q 2, PROVIDE 3-1/2" 300OPSI CONC. SLAB W/ 6x6xW1.4xW1.4 WELDED WIRE LU MESH PLACED AT MID DEPTH ON 6 MIL. VAPOR BARRIER ON COMPACTED FILL (FIBER MESH MAY BE USED ILO WWM, WHEN FIBER W MESH. MEETS OR EXCEEDS SPECIFICATIONS SET FORTH IN CURRENT , EL CODE EDITION. d' 3, VERT. #5 BAR TO BE HOOKED AT TOP & BOTTOM (FTG. & TIE BEAM o ENDS) W/MIN. 12 BAR DIAMETER LEGS EXCLUDING BEND @ EA. END. LAP SPLICES SHALL BE NO LESS THAN 25 O 4. CONSULT W/MAN. SPECIFICATIONS PRIOR TO POURING OR I-- Z RECESSING DOOR SILLS. 0 Q 5, EXTERIOR SLABS SHALL SLOPE 1/8" PER FOOT AWAY FROM HOUSE. 6. CONTROL JOINTS (IF SHOWN) ARE NOT REQUIRED BY CODE BUT ARE SUGGESTED (ESPECIALLY WHEN USING FIBER REINF. CONC.) O U CONTROL JOINTS TO BE SAW CUT A DEPTH OF 1/4" OF THE U THICKNESS OF THE SLAB. FILL CUT W/APPROVED JOINT MATERIAL OR Z W USE ALTERNATE APPROVED METHOD. C) 7. MECHANICAL EQUIP: LOCATIONS WILL BE DETERMINED BY COMMUNITY & COUNTY CODES. 8. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL m SYSTEMS SHALL BE RAISED AT LEAST 3" ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS OLL - - J 9. NO WOOD STAKES PERMITTED IN FOUNDATION. W W 10. PENDING SITE CONDITIONS, FOUNDATION MAY HAVE TO BE STEPPED H 0� DOWN. SEE SHEET SDI FOR ADDITIONAL INFORMATION. GC TO WO DETERMINE STEP LOCATIONS IF REQUIRED 11, SEE TYPICAL DETAIL ON LINTEL PLAN FOR REQUIRED STEEL BENDS Z AND LAP SPLICE. SEE DTL MF09 AND MF10 ON SDI FOR STANDARD O `011111111ra® LU M FOOTING STEP DOWN AND CORNER INFORMATION. `®®® ®®®�® A. 12. ANY EQUIPMENT AND/OR APPLIANCES HAVING AN IGNITION SOURCE >°°°®o®®•°b��l/j�'''�® .�'".. Y SHALL BE ELEVATED A MIN OF 18". CONTRACTOR TO PROVIDE SUCH ® °•p = z PLATFORM w/ EITHER MASONRY OR WOOD CONSTRUCTION ® 0 w S qp Q U 13. ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER o V , µ r. ri -� COMPACTION: 2000 PSF (SEE SOILS REPORT AND SPECIFICATIONS ° o �.. ��� q w W FOR COMPACTION REQUIREMENTS). IF SOIL CONDITIONS IN THE • CIO• PROJECT DO NOT MEET OR EXCEED THE CAPACITY, THE GENERAL d• °••®® ®•®®° %< 0 O CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO ®••••m•• ®® ..J N DESIG SOIL TO B FOUNDATIONPOUR O OF ORGANIC MATERIAL AND COHESIOVE SOILSN. 'yam u.. 11111l+ COMPACTED IN 12" LIFTS TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM -1557 (MODIFIED PROCTOR). W THE FOUNDATION SIZES INDICATED ON THE FOUNDATION PLAN HAS ii BEEN DESIGNED FOR A MINIMUM SOIL BEARING CAPACITY OF 2000 � PSF: O O 14. PENDING SITE CONDITIONS, IF STEMWALL IS REQUIRED, G.C. TODETERMIU STEMWAIIRED COURSES FOR STEMWALL L CHARTON SDI FOR REQUIRED REINFORCEMENTION.p SEE Q/ µ cv FOOTING SIZES PENDING DEPTH OF STEMWALL, cli `'? 0 r- H o FOOTING SCHEDULE n O12"x12"x12" dp w/ #5's EQUALLY SPACED EA. U • 1 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (2) # 5 E.W. O BARS & 3 MIN. COVER TO EDGE OF CONC.",,,I 2O24"x24"x12" dp w/ #5's EQUALLY SPACED EA. Z�� U WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (3) # 5 E.W. O BARS & 3" MIN. COVER TO EDGE OF CONC. 0 28"x28"'x12" dp w/ #5's EQUALLY SPACED EA. O 2.3 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (4) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. a 30"x30"x12" dp w/ #5's EQUALLY SPACED EA. 2.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (4) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. I' 32"x32"x12" dp w/ #5's EQUALLY SPACED EA. 7 2.6 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (5) # 5 E.W. 0�-' L BARS & 3" MIN. COVER TO EDGE OF CONC. O36"x36"x12" dp w/ #5's EQUALLY SPACED EA. �_ z WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (5) # 5 E.W. Q � o BARS & 3" MIN. COVER TO EDGE OF CONC. W— LLI J 0) i 42"x42"x12" dp w/ #5's EQUALLY SPACED EA. O N 3.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (6) # 5 E.W. z0 w Z BARS & 3" MIN. COVER TO EDGE OF CONC. I-- z _ w 48'x48"x1Z 2" dp w/ #5's EQUALLY SPACED EA. Q O 0 O 4O WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (7) # 5 E.W. U Z ~ 0 U 0 C° �WzN BARS & 3" MIN. COVER TO EDGE OF CONC. OJ J z W~o 0 54"x54"x16" dp w/#5's EQUALLY SPACED EA. W : Q 00 °- � c(Oo 4.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (8) # 5 E.W. (n z -r 3 w Wo I=— 0 Q0 BARS & 3" MIN. COVER TO EDGE OF CONC. O �u'z 60"x60"x16" dp w/#5's EQUALLY SPACED EA. 5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (9) # 5 E.W. U O 15Q- z O BARS & 3" MIN. COVER TO EDGE OF CONC. W Q W H N I— z J Z O U N Q SYMBOLS LEGEND 0 0 O U. N INDICATES GROUT FILLED CELL WITH (1) VERT. #5 CONT. FTG. Q U j TO TIE BEAM (6'-8" O.C. MAX U.N.O.)_ z W p = INDICATES GROUT FILLED CELL WITH (2) VERT. #5 CONT. FTG. W — TO TIE BEAM, p a 0 INDICATES GROUT FILLED CELL WITH NO REINFORCEMENT. (� Z INDICATES 45° CORNER BLOCK GROUT FILLED WITH (2) VERT. Q #5 CONT. FT.G TO TIE BEAM. O Q _.JLi0 Z_ Z O' W h- OO 11 3: Q 00 W F- Z J O U Owe 0! 0 Y 0 O o 0 O z LU �� © w w O -- LJ ) Q W = O ~ ary ~ v STRUCTURAL ENG: RMG Q DRAFTING: F— Z -STRUCT: JV W QC CHECK: CC LU JOB No. TM - 2170194 SCALE: AS INDICATED DATE: 04/12/2017 FOUNDATION PLAN 1 /4"=1'-0" S 2 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. i i 2'-8" 1 16'-0" 1 2'-8" SYMBOLS LEGEND LU INDICATES GROUT FILLED CELL WITH (1) VERT. #5 CONT. FTG. Q ~ TO TIE REAM (6'-8" O.C. MAX U.N.O.). z 0 ® INDICATES GROUT FILLED CELL WITH (2) VERT. #5 CONT. FTG. U) TO TIE BEAM. C� It 0 INDICATES GROUT FILLED CELL WITH NO REINFORCEMENT. N INDICATES 45' CORNER BLOCK GROUT FILLED WITH (2) VERT. p #5 CONT. FT.G TO TIE BEAM. 1- Z 0 O W — = I— n IZ LU O U U (D W z C) O J m `t 0 O -- J LL W W U- C? O ro � z co • d®®� °- �'®®®goo®p®®� Y 00 o 000®®�®`per -1z ® W Q Qk- s 7 a Q Cr o Of J ® m U- � o i 0 0 ci Q ] it"hill" D_ o H mmi z i- W*4 O U O l k U z-, O 0 CL 4cc ui 0 I- U H 0 Z io W U) ih �f LU -�`-~ z L U%zI-MI� Q O 06 LWz1?�rn v. U Z U H p U� 0 0 ^ 0wz _ d000Ou) cva ►- = Z zj�Uj o H ow<w00 ;0 2� LU Q U)Q z J O Z0WNQ Cr- 0 U� U W zw ¢ o p cnW .�. Cl) CL z 0 Q o Q o z Z 3: O W 00 ao F- Q N z W~ ZJO C/) Owe ~ 0 LLI o00 ' f-o 0rO z Z c� X: 0 Im o~ ��� �w wO � p ia-aH p ry U � U) STRUCTURAL ENG: RMG Q DRAFTING: h- z-STRUCT: JV W _ 0 QC CHECK: CC r JOB No. TM 2170194 SCALE: AS INDICATED ~ DATE: 04/12/2017 DOWEL LAYOUT PLAN- 1/4 11=11-011 S3 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. 1 11 I- -AKA T- P -1 I ... I//-'\4 AA N � =5 � Z5 WALL LEGEND a F- w Q _1 = 10'-0" T.O.M. = 11'-0" T.O.M. W C) 1 I 0 rr 12'-0" T.O.M. ® = INTERIOR/EXTERIOR w ---- BEARING WALLS VERIFY HGT. W/ ARCHITECTURAL PLAN U,N.O. N Z 0 H Z 00 LLJ 0 U'^ U vJ Z w J W 0 _ ....., . --_ .- -... ... J LL w w F- W LL LLL 0 (n z ®®®®►aNi�srrrr,' a00 0 ®q �'00 e�p°°®®re°®®,% I��25 T.W. z s b S7 i • �W U ir_ CAW Q 00 ° ® co (�® \ w \y LL � ®®rrrrolr�1�®p CL w _ \ 0 O C..) w Z � Q N rSry o LU Q �o LL 0 O cn O [L w I- Zv U) J cn Q C L. (D I.- o U � U�o� LL W Jrn — � O z 06 H z U) - 0) (,'' QO U z U1-pU( CO F- iz O J o 0 w �/ QOO°-- m � LL zz Z H P w w o H O wawZoo w Q 0�Qa U I- LL of 04 J p a ��N¢ o�.J � (.) I" LL z w o=(� w�r- 0 z 0 Q o Q Q z Z O F= oo �r 00 o > N ZJQ U) 0 Lu -j C W 0 0 0 z 0 0 m o ( O � r---�--�- w >-W0 -- w 0 �a� ry U STRUCTURAL ENG: RMG Q DRAFTING: H Z-STRUCT: JV w 0 QC CHECK: CC Uj JOB No. TM - 2170194 Z SCALE: AS INDICATED ~ DATE: 04/12/2017 FIRST FLOOR FRAMING PLAN ,1.1,_0ll S 4 NOTE SEE PAGE S4 1 FOR NOTES AND CONNECTOR LEGEND 114 OVIDE (2)2x12 SYP#2 BLOCKING BETWEEN USSES UNDER POST SUPPORTING GIRDER �V. ATTACH USING ►HUC210-2 @ EA. END, TRUSS TO BE BLOCKED SLID FOR HANGER ATTACHMENT COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR &ASSOCIATES, LLC is strictly prohibited. BEARING WOOD WALL SCHEDULE TAG STUD SPACING LUMBER SPECIES CONNECTION & FASTENERS UPLIFT CAP. (plf) BLOCKING TOP BOTTOM BW1 16" SPF (3)12d TOENAILS (3)12d TOENAILS NO UPLIFT MID -SPAN BW2 16" SPF 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf MID -SPAN BW3 16" SPF 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf 3rd. PT. BW4 12" SPF (3) 12d TOENAILS (3) 12d TOENAILS NO UPLIFT MID -SPAN BW5 12" SPF 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf MID -SPAN BW6 12" SPF 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf gird. PT. 3 BW7 16" SYP (3) 12d TOENAILS (3) 12d TOENAILS NO UPLIFT MID -SPAN BW8 16" SYP 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf MID -SPAN BW9 16" SYP 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf 3rd. PT. BW10 12" SYP (3) 12d TOENAILS (3) 12d TOENAILS NO UPLIFT MID -SPAN BW11 12" SYP 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 If p MID -SPAN BW12 12" SYP 1/2" THREADED ROD @ 48" O.C. ADJUST AS REQ'D TO MISS STUDS 1160 plf Ord. PT. 3 STANDARD BEARING WALL W/THREADED ROD NOTES 1. VERIFY w/PLAN FOR WALL SIZE. ASSUME 2x4 STUDS U.N.O. 2. ALL LUMBER TO BE EITHER SPF #2 OR SYP #2 U.N.O. (CAN BE SUBBED WITH OUT REVIEW) ALWAYS NAIL STUDS TO TOP AND BOTTOM PLATE W/ (3) 12d TOENAILS 3. IF BEARING WALL IS NOT CALLED OUT CONTACT E.O.R. 4. IF "BW" CALLED OUT ON 2nd FLR. SEE PLAN FOR STUD TO STUD CONNECTIONS. 5. ATTACH ALL STUDS TOP AND BOTTOM W/ (3) 12d TOENAILS. 6. MID OR 1/3 PT BLOCKING TO BE 2x W/ (2) 12d TOENIALS EACH END. 7. Y2" THREADED ROD w/ MIN 6" EMBED (OR 6" BELOW LOWEST SLAB ELEVATION AT STEP) w/ SIMPSON SET EPDXY. SEE ABOVE FOR SPACING. CENTERED w/in TOP PLATE. FOLLOW SIMPSON INSTRUCTIONS FOR INSTALLATION OF ROD AT BASE. NUT AND 2"x2"x1/8" WASHER @ TOP. THREADED ROD TO BE PLACED 6" AWAY FROM ANY STRUCTURAL COLUMN UNLESS PLANS INDICATE CONNECTIONS. 8. 2x P.T. PLATE AT BASE OF BRG.WALL W/ THREADED ROD. NO ADDIT'L BASE CONNECTIONS TO THE FOUNDATION ARE REQ'D IF B RG. WALL IS INDICATED WITH BW1, BW4, BW7, & BW10. THESE WALLS ARE ONLY SUPPORTING THE FLOOR LOAD AND DO NOT HAVE UPLIFT, THE STUDS ARE TOENAILED/ ENDNAILED TO THE PLATE AND THE 2X BASE PLATE CAN BE ATTACHED WITH HARD CASED GUN NAILS & THE ANCHOR BOLT ATTACHMENT INDICATED IN BEARING WALL SCHEDULE IS NOT REQ'D. 9. AT SHEAR WALL LOCATIONS ONLY: NUT & WASHER @ BASE OF THREADED ROD ARE REQ'D. SEE PLAN FOR ADDIT'L SHEARWALL INFO. AND DETAILS. 10. FOR BEARING WALL TO MASONRY CONNECTION SEE DETAIL MD03/SD2 U.N.O. ON PLAN. 11. AT HEADER LOCATIONS WITHIN BEARING WALLS SEE DETAIL WF09/SD3 U.N.O. ON PLAN. 12. COLUMNS w/in BEARING WALLS w/ UPLIFT THAT DO NOT SHOW A BASE CONNECTION: CONTRACTOR TO INSTALL THREADED ROD w/in 6" OF COL. (MIN CENTER TO CENTER SPACING OF THREADED ROD IS 8") 13. IF PLUMBING IS TO BE RUN THROUGH BEARING WALL, CONTACT FOR FOR FURTHER REVIEW. 14. AT NON -BEARING WALL LOCATIONS 2x4 SPF#2 STUDS @ 24"o.c. MAX. ARE ADEQUATE. AT NON -BEARING HEADERS USE (2)2x4 FLAT w/(3)12d TOENAILS EA. SIDE AND CRIPPLES AT 24"o.c. AT 2-STORY OPEN AREAS INSTALL NON -BEARING WALL STUDS @16"o.c. A SINGLE BASE PLATE (P.T. IF AGAINST CONCRETE) AND SINGLE TOP PLATE ARE ADEQUATE LEAVE A 4" GAP FROM TRUSS TO TOP PLATE AND ATTACH USING EITHER (2)12d TOENAILS OR SIMPSON DTC CLIP. ATTACH BASE PLATE w/ EITHER GUN NAILS @32"o.c. OR (2)12d NAILS TO EACH FLOOR TRUSS. COLUMN SCHEDULE qO (2)2X4 SPF #2 BUILT UP STUD COLUMN B O (3)2X4 SPF #2 BUILT UP STUD COLUMN C O (4)2X4 SPF #2 BUILT UP STUD COLUMN < (2)2X6 SPF #2 BUILT UP STUD COLUMN O(3)2X6 SPF #2 BUILT UP STUD COLUMN O(2)2X8 SPF #2 BUILT UP STUD COLUMN O(3)2X8 SPF #2 BUILT UP STUD COLUMN O(3)2X4 SYP #2 BUILT UP STUD COLUMN O(2)2X6 SYP #2 BUILT UP STUD COLUMN O(2)2X8 SYP #2 BUILT UP STUD COLUMN OL 44 SYP #2 POST MO 6x6 SYP #2 POST NO 8x8 SYP #2 POST PO 3-1/2"x3-1/2" LVL COLUMN. QO 3-1/2"x5-1/4" LVL COLUMN. RO 3-1/2"x7" LVL COLUMN. O3-1/2"x9-1/2" LVL COLUMN, O5-1/4"x5-1/4" LVL COLUMN. O5-1/4"x7" LVL COLUMN. XO 7'W" LVL COLUMN. O3 1/2" X 11 7/8" LVL COLUMN O5 1/4" X 9 1/2" LVL COLUMN STANDARD COLUMN NOTES 1. NAIL ALL BUILT-UP STUDS PER DTL. WF08/SD4. 2. ALL POST/ LVL COLUMNS IN EXTERIOR CONDITION SHOULD BE P.T. OR WOLMANIZED. 3. CONTRACTOR TO USE ABU BASE CONNECTORS @ SPF/SYP SOLID POSTS. AT EXTERIOR CONDITIONS 44: ABU44 w/(12)16d NAILS & 4" EPDXY ANCHOR WMIN. 7" EMBEDMENT 6x6: ABU66 w/(12)16d NAILS & 5" EPDXY ANCHOR w/MIN. 7" EMBEDMENT 8x8: ABU88 w/(18)16d NAILS & (2)a' EPDXY ANCHORS w/ MIN. 7" EMBEDMENT 4. POST/LVL INSTALLED WITHIN BRG. WALL TO BE WITHIN TOP AND BASE PLATE U.N.O. ON PLANS. 5. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS. NAIL SCHEDULE STANDARD NAIL GENERAL DIAMETER/ LENGTH 8d .131" x 2-1" 10d .148" x 3" 12d .148" x 31' 16d .162" x 31" 8d RING SHANK .113" x 28" NAILING NOTES 1. CONTRACTOR MAY USE A DIFFERENT NAIL THEN INDICATED AS LONG AS IT MEETS OR EXCEEDS THE DIAMETER AND LENGTH INDICATED. 2. CONNECTORS MAY USE DIFFERENT NAIL LENGTHS, MINIMUM NAIL LENGTH PER CONNECTOR IS REQ. IF LONGER NAIL IS USED IT IS ADEQUATE AS LONG AS IT DOES NOT EXTEND THRU THE MEMBER IT'S BEING ATTACHED TO. CONNECTOR SCHEDULE VALUES VALUES TAG SIMPSON CONNECTOR TYPE SPF(Ib) SYP(Il META16 w/(7) 10dx12" NAILS OR El META20 w/(7) 10d x 11" NAILS FRAME TO CMU 1450 1450 (2)META16 OR (2)META20 (1)ply TRUSS (10)10d x 1"' NAILS FRAME TO CMU (1)ply 1985 (1)ply 1985 (2)ply TRUSS (12) 16d x 11" NAILS (2)ply 1900 (2)ply 1900 H10A w/(18)10d x 11" NAILS OR H10A 1015 H10A 1340 (2)ply TRUSS H10A-2 w/(18) 10d x 12" NAILS FRAME TO FRAME H10A-2 1070 H10A-2 1245 HTS20 w/(24)10d x 11" NAILS El (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 1245 1450 (2)HTS20 w/(24)10d x 12" NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 2490 2900 H2.5A w/(10)8d FRAME TO FRAME 535 600 MTS12 w/(14)10d x 12" NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 860 1000 a MGT w/(22)10d L EPDXY ANCHOR w/SIMP. SET EPDXY MIN. FRAME TO CMU 3140 3140 7" EMBEDMENT HTT4 w/(18)16d x 21" NAILS & 4" EPDXY ANCHOR w/SIMP. FRAME TO CMU 3640 4235 SET EPDXY MIN. 7" EMBEDMENT HGT-2 w/(16)10d NAILS Wa" EPDXY ANCHOR w/SIMP. SET 10 FRAME TO CMU 6280 6280 EPDXY MIN. 5" EMBEDMENT 11 HTSM16 w/(8)10d NAILS & (4) 4 x 24 TAPCONS FRAME TO CMU 1020 1175 12 LSTA18 w/(14)10d NAILS HEADER TO STUDS 1110 1235 13 (2)LSTA18 w/(14)10d NAILS HEADER TO STUDS 2220 2470 14 LSTA18 w/(14)10d NAILS CENTERED EACH STUD STUDS TO BEAM/GT 833l 928l 15 LSTA24 w/(18)10d NAILS CENTERED EACH STUD STUDS TO BEAM/GT 1235 1235 16 MSTC28 w/(36)16d SINKERS CENTERED STUDS TO BEAM/GT 2980 3455 17 MSTC40 w/ (52) 16d SINKERS CENTERED STUDS TO BEAM/GT 4305 4745 18 LTT20B w/(10) 10d NAILS & g" EPDXY ANCHOR w/SIMP. SET COLUMN TO FTG. OR 1290 1300 EPDXY MIN. 7" EMBED. CMU HTT4 w/(18) 16d x 22" NAILS w/$" EPDXY ANCHOR w/SIMP. 1g SET EPDXY MIN. 7" EMBED. -AT LVL/PL COLUMNS USE COLUMN TO FTG. 3640 4235 (1*)#10x12" SD SCREWS INSTEAD OF NAILS (3)HTS20 w/(24)10d x 12" NAILS 20 (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 3735 4350 21 MSTCM40 W/ (14) 16d SINKERS AND (10) 1/4"x2-1/4" FRAME TO CMU 2420 2800 TAPCONS 22 SIMPSON HGUS 5.50/10 W/ (63) 16d NAILS GIRDER TO COL./ BEAM 9100 4095 HUC210-2 HEADER TO CMU w/ (18) 1/4"x2-3/4" SIMPSON GRAVITY:5085 GRAVITY:5085 23 TITENS & (10) 10d NAILS FRAME TO CMU UPLIFT:1810 UPLIFT:1810 24 HUS26 TO LEDGER W/(14)16d NAILS AND TO TRUSS FRAME TO FRAME 1335 1550 W/(6)16d NAILS 25 HUSC210-2 W/(8)16d NAILS TO BEAM AND (8)16d NAILS TO FRAME TO FRAME GRAVITY:2125 GRAVITY:2125 COLUMN UPLIFT:3290 UPLIFT:3290 26 LTT20B w/(10) 10d NAILS & 4' EPDXY ANCHOR w/SIMP. SET EPDXY MIN. 7" EMBED. FRAME TO CMU 1290 1300 STANDARD CONNECTOR NOTES 1. ALL TRUSS/BEAM TO MASONRY CONNECTIONS TO BE SIMP. META16, U.N.O. ON PLAN. AT FLOOR TRUSSES PARALLEL TO MASONRY WALLS CONNECT w/SIMP. META16 @ 24"o.c. OR 32"o.c. VERIFY w/ TRUSS SHOP DRAWINGS FOR VERTICAL SPACING WITHIN FLOOR TRUSS. (IF SITTING ON FRAME WALL USE SIMP. LSTA18(14) @ 24"o.c. OR 32"o.c.) CONNECT ALL CONTINUOUS RIM BOARDS TO TOP OF MASONRY W/SIMP. META16, @ 32"o.c. MAX. AND (2) AT EACH CORNER. 2. ALL TRUSS/BEAM TO FRAME CONNECTIONS TO BE SIMP. H10A FOR SINGLE PLY, OR H10A-2 FOR 2-PLY U.N.O. ON PLAN 3. CONNECT ALL TYPICAL HIP JACKS (CORNER JACKS) TO FRAME USING SIMP. H2.5A CONNECTOR. IF UPLIFT EXCEEDS 535lbs USE (2) H2.5A CONNECTORS. 4. CONNECT ALL INTERIOR FLOOR TRUSSES/JOISTS TO INTERIOR BRG. WALLS USING (3)12d TOENAILS. 5. ALL TRUSS TO TRUSS CONNECTIONS TO BE SPECIFIED BY TRUSS MANUFACTURER, U.N.O. ON PLAN. 6. MISSED LINTEL STRAPS: CONTRACTOR TO INSTALL SIMP. HTSM16 @ EACH MISSED META16 STRAP LOCATION. IF DOUBLE META16 @ A 2-PLY OR 1-PLY TRUSS IS MISSED, USE (2)HTSM16 STRAPS. IF UPLIFT IS HIGHER THEN 2100lbs, CONTACT E.O.R. FOR FURTHER REVIEW. STANDARD HEADER NOTES 1. VERIFY w/PLAN FOR CORRECT LENGTH OF HEADER REQ'D. SIZE INDICATED ON PLAN IS MINIMUM REQ'D. PER LOCATION. LARGER HEADER MAY BE INSTALLED w/OUT APPROVAL FROM E.O.R. 2. ALL HEADER JACKS/KINGS TO MATCH WALL LUMBER GRADE U.N.O. ON PLAN. ATTACH STUDS TOGETHER FOLLOWING DTL. WF08/SD4. 3. NAIL #2 SYP HEADER PLIES TOGETHER USING: (2) ROWS OF 10d NAILS @12" O.C. ONE SIDE. MIN. 2" FROM TOP AND BOTTOM FOR 2X6 AND 2X8 HEADERS. (3) ROWS OF 10d NAILS @12" O.C. ONE SIDE. MIN. 2" FROM TOP AND BOTTOM FOR 2X10 AND 2X12 HEADERS. NAILING ABOVE IS FOR TOP -LOADED HEADERS ONLY. CONTACT E.O.R. IF MEMBERS BUCKET INTO HEADER 4. NAIL KING STUDS TO HEADER w/(3) 10d TOENAILS PER SIDE IN ADDITION TO NAILING PER HEADER SCHEDULE. 5. IF MORE THEN (1)KING IS REQ'D. AS PER HEADER SUPPORT TABLE, GC TO INSTALL REQ'D. NAILS FROM 1st KING INTO HEADER THEN ATTACH ADDIT'L KING PER DTL. WF08/SD4. OTHERWISE, CONTACT E.O.R. FOR REQ'D. WOOD SCREWS. 6. IF HEADER IS NOT SPECIFIED CONTACT E.O.R. 7. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS. 8. SEE DTL. WF09/SD3 FOR 1 ST FLOOR HEADER CONSTRUCTION AND CONNECTIONS AT 2 STORY CONDITIONS. SEE 2ND FLOOR NOTES FOR MORE INFO. BEAM SCHEDULE TAG BEAM SIZE CONNECTIONS TO POST: SIMP. HTS20 OR MSTA18 TO BEAM: SIMP. HUC48 w/(14)16d & (6)-10d NAILS (2)2x8 #2 SYP TO MASONRY: SIMP. HU48 OR HUC48 B2x8 WITH 1/2" FLITCH w/(6)10d NAILS & (14)4"x22' PLATE TAPCONS ON MASONRY: (1) SIMP. MSTAM24 TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (2)2x10 #2 SYP (10) 10d NAILS B2x10 WITH 1/2" FLITCH TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d PLATE NAILS & (18)-!'W4" TAPCONS ON MASONRY: (1) SIMP. MSTAM24 TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (2)2x12 #2 SYP (10) 10d NAILS B2x12 WITH 1/2" FLITCH TO MASONRY: SIMP, HU410 OR HUC410 w/(10)10d PLATE NAILS & (18)4'x24" TAPCONS ON MASONRY: (2) SIMP. MSTAM24 TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS B3.5x11.25 (2)1.75"x11.25" LVL TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)4'x2-1" TAPCONS ON MASONRY: (2) SIMP. MSTAM24 TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS B3.5x11.875 (2)1.75"x11.875" LVL TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)4'x24" TAPCONS ON MASONRY: (2) SIMP. MSTAM24 TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS B3.5x16 (2) 1.75"x16" LVL TO MASONRY: SIMP, HU410 OR HUC410 w/(10)10d NAILS & (18)- "x24" TAPCONS ON MASONRY: (2) SIMP. MSTAM24 TO POST: (2) SIMP. HTS20 OR LSTA18 ON MASONRY: (2) SIMP. MSTAM24 B5.25x16 (3) 1.75"x16" LVL * U.N.O.FASTEN LVL PLIES TOGETHER USING (3) ROWS OF 1/4" X 3 1/2" SIDS SCREWS @ 24" O.C. EACH SIDE TO POST: (2) SIMP. HTS20 OR LSTA18 ON MASONRY: (2) SIMP. MSTAM24 B3.5x20 (2) 1.75"x20" LVL * U.N.O.FASTEN LVL PLIES TOGETHER USING (4) ROWS OF 1/4" X 3 1/2" SIDS SCREWS @ 24" O.C. EACH SIDE STANDARD BEAM NOTES 1. NAIL ALL (2) 2x SYP BEAMS TOGETHER USING (3) ROWS OF 12d NAILS @ 12" O.C. (TYP. ONE SIDE) MIN. 2" FROM TOP AND BOTTOM OF BEAM 2. NAIL ALL 2-PLY LVL BEAMS (MAX. 12" DEEP) TOGETHER USING (3) ROWS OF 12d NAILS @ 6" O.C. (TYP. ONE SIDE) MIN 2" FROM TOP AND BOTTOM OF BEAM 3. VERIFY w/PLAN CORRECT LENGTH OF BEAM REQ'D. (MIN. 4" BRG. EA. END) 4. SEE PLAN FOR TOP OR BOTTOM OF BEAM INDICATIONS. 5. BEAMS ARE NOT TO BE DRILLED OR NOTCHED IN ANY WAY WITHOUT WRITTEN APPROVAL FROM THE E.O.R. 6. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS HEADER SCHEDULE TAG HEADER FASTENERS H2x6 (2)2x6 #2 SYP w/2" FLITCH PLATE ATTACH KING STUD TO HEADER w/(6) 16d NAILS H2x8 (2)2x8 #2 SYP w/2" FLITCH PLATE ATTACH KING STUD TO HEADER w/(8) 16d NAILS H2x10 2)2x10 #2 SYP w/2" FLITCH PLAT ATTACH KING STUD TO HEADER w/(10) 16d NAILS H2x12 2)2x12 #2 SYP w/2" FLITCH PLAT ATTACH KING STUD TO HEADER w/(10) 16d NAILS H3.5x5.5 (2)1.75"x5.5" LVL ATTACH KING STUD TO HEADER w/(6) 16d NAILS H3.5x7.25 (2)1.75"x7.25" LVL ATTACH KING STUD TO HEADER w/(8) 16d NAILS H3.5x9.25 (2)1.75"x9.25" LVL ATTACH KING STUD TO HEADER w/(10) 16d NAILS H5.5x11.25 (3)1.75"x11.25" LVL ATTACH KING STUD TO HEADER w/(12) 16d NAILS H3x12 (3) 2x12 #2 SYP w/ 2" FLITCH PLATE BETWEEN PLIES ATTACH KING STUD TO HEADER w/(10) 16d NAILS HEADER SUPPORT # JACKS/KINGS REQ'D. @ OPENING OPENING SIZE SEE PLAN FOR WALL WIDTH JACKS @ EA. END KINGS @ EA. END 1'-0" TO T-11" 1 1 4'-0" TO 7'-11" 2 2 8'-0" TO 9'-11" 2 3 1 U-0" TO 12'4" 3 4 ROOF NOTES: 1. THE ROOF PLAN DEPICTED IS NOT INTENDED TO SERVE AS A TRUSS DESIGN. 2. TOP PLATE HEIGHTS VARY, SEE BUILDING SECTIONS, WALL SECTIONS AND ELEVATIONS FOR BEARING HEIGHTS. 3. TRUSS SPACING SHALL BE 24" O.C. MAX. UNLESS OTHERWISE NOTED. CONVENTIONAL FRAMING SHALL BE 16" O.C. MAX. OR AS OTHERWISE NOTED. 4. FRAME WALLS UP TO UNDERSIDE OF ROOF TRUSSES AT ALL NON -BEARING WALLS AND AT VOLUME AREA UNLESS NOTED OTHERWISE. STUDS CAN BE 24" O.C. W/ SINGLE TOP AND P.T. BASE PLATE LEAVE 1 1/2" GAP FROM TOP PLATE TO TRUSS BOTTOM CHORD. CONNECT TRUSS TO NON -BEARING WALL w/ SIMPSON DTC OR (2) 12d TOENAILS. 5. ALIGN TRUSSES AND HAND FRAMING SO ALL GYPSUM WALL BOARD WILL BE CONTINUOUS FROM FLOOR TO CEILING. 6. TRUSS MANUFACTURER TO INSURE DESIGN CONSIDERATION TO THE FOLLOWING ADDITIONAL LOADS: A) ALL CEILING HUNG SOFFITS AND SOFFITS WITH CABINETS AS SHOWN ON PLANS. B) ATTIC LOCATED HVAC UNITS AS SHOWN ON PLANS. 7. REFER TO MANUFACTURER SPECIFICATIONS FOR INSTALLATION REQUIREMENTS OF ALL HARDWARE BEFORE INSTALLATION. 8. GC REQ'D TO PROVIDE PERMANENT BRACING/ BLOCKING PER BCSI 1 (CURRENT EDITION). SEE COVER SHEET NOTES FOR MORE INFO & STANDARD DETAILS IN THIS DRAWING SET FOR ADDITIONAL BRACING/ BLOCKING INFO. 9. ALL TRUSS -TO -TRUSS CONNECTORS ARE TO BE PROVIDED BY TRUSS SUPPLIER. THIS INCLUDES BUT IS NOT LIMITED TO PIGGY BACK TRUSSES AND VALLEY TRUSSES 10. USE 5/8" TYPE X GYPSUM BOARD ON CEILING IN GARAGE WHEN LIVING SPACE IS ABOVE THE GARAGE. 11. IF ROOF TRUSS LAYOUT DEPICTS TRUSS LABELS OR ID'S, THIS LAYOUT HAS BEEN PROVIDED BY A TRUSS COMPANY TO USE FOR THE DESIGN OF THIS PROJECT. OTHERWISE AN ENGINEERED LAYOUT HAS BEEN DETERMINED BUT PRIOR TO CONSTRUCTION OR TRUSS FABRICATION, FINAL TRUSS LAYOUT AND TRUSS SHOP DRAWS ARE TO BE SUBMITTED TO ENGINEER OF RECORD (E.O.R.) FOR REVIEW AND APPROVAL. AT THIS TIME THE E.O.R. RESERVES THE RIGHT TO REVISE THE PLAN AS REQUIRED PER THE REVIEW OF THE FINAL TRUSS LAYOUT AND TRUSS SHOP DRAWS, ADDITIONAL FEE'S MAY APPLY. STARTING CONSTRUCTION OR TRUSS FABRICATION PRIOR TO THIS REVIEW IS NOT ADVISED, AND THE E.O.R. IS NOT RESPONSIBLE FOR ADDITIONAL COSTS DUE TO REVISIONS OF THE PLAN. IF CONVENTIONAL FRAMING IS SHOWN, NO TRUSS APPROVAL IS REQUIRED, UNLESS LAYOUT IS REVISED W/OUT WRITTEN APPROVAL FROM MCD. W Q I-- Z Q w 0 (A w v 0 N_ z O z o p L0 � w o U Z W Z C) J m 0 O LL w W H l w ,O ,� \\ ®®i�tl1116PAdpB w M CD l� y LIJ � °°®•�lj�®a' J z u. ® p W C!q U IJJLU® J LLI < Z p ry 1M 11- 12. IF DESIGN DOCUMENTS INDICATE THAT AN A/C UNIT IS TO BE RECESSED INTO THE w ROOF SYSTEM, THE TRUSS SUPPLIER IS TO COORDINATE WITH THE DESIGNER AND -' BUILDER TO DETERMINE THE REQUIRED SIZE. (2) 751b MIN POINT LOAD SHOULD BE CL ADDED TO EITHER THE TOP OF BOTTOM CHORD OF THE TRUSS IN THE AFFECTED O q AREAS. THIS LOAD SHOULD BE INDICATED ON THE TRUSS SHOP DRAWINGS. U CONNECTIONS OF THE A/C UNIT TO THE TRUSSES SHOULD BE SUPPLIED BY EITHER Z THE CONTRACTOR OR A/C SUPPLIER. SEE TB01/SD2 FOR MORE INFORMATION. Q 6 7 N ILDER NOTE: BUILDER a IF THE TRUSS LAYOUT SHOWN DOES NOT MATCH THE i�;', z° TRUSS MANUFACTURERS LAYOUT ""' ----STOP---- _ AND CALL THE ENGINEER OF RECORD PRIOR TO w PLACEMENT OF ANY TRUSSES o o .�. NAILING SCHEDULE: w ROOFS: ROOF SHEATHING TO BE 15/32" OSB (WITH SHINGLE), 5/8" OR 19/32" OSB (WITH TILE) FASTENING WITHIN 4'-0" OF EAVES TO BE 4" O.C. AT ALL SUPPORTED EDGES AND 6" H O.C. IN FIELD. FOR ALL OTHER AREAS NAIL @ 6" O.C. AT ALL SUPPORTED EDGES AND U n/ 6" O.C. IN FIELD. SHEATHING TO BE PLACED WITH LONG DIMENSION PERPENDICULAR L.L TO SUPPORTS (TRUSSES). PROVIDE PLY CLIPS AT ALL UNSUPPORTED ROOF O SHEATHING JOINTS EXCEPT AT PITCH CHANGE LOCATIONS. PLY CLIPS TO BE p Z SPACED NO MORE THAN 24" O.C. < (D o GABLE ENDS: w �- o l _ rn r r` W ALL SHEATHING TO BE MIN. 15/32" O.S.B. AND SHALL BE NAILED (1) ROW @ 3" O.C. Z W J . N 0 z H CO r E AT TOP PLATE AND (1) ROW AT BOTTOM PLATE OF WALL, 6" O.C. ALL OTHER O Z � N z (1? � rn 8 ¢ O EDGES AND 6 IN FIELD. BLOCKING SHALL BE PLACED AT ALL SHEATHING JOINTS. Q 0 0r (r .E U 7 Z L Z U CO °Q 5 O Wz EXTERIOR WALLS: O W (no z a C, SEE WF10/SD4 FOR MORE INFO. = I- U p = � U) ' 2 z w w o NAILS: W ZO < W O O NAILS USED IN ROOF SHEATHING APPLICATIONS SHALL BE 8d RING SHANK NAILS. j U 3: 00 a ALL OTHER SHEATHING APPLICATIONS SHALL BE 8d, 8d RING OR SPIRAL SHANK, w Q S u� Q HAND OR GUN DRIVEN NAILS. GUN DRIVEN NAILS SHALL HAVE HEAD SIZE U LU ~ "- N -i O < EQUIVALENT TO HAND DRIVEN NAILS; FASTENERS FOR PRESERV- ATIVELY Q J U N TREATED WOOD SHALL BE HOT -DIPPED ZINC -COATED GALVANIZED STEEL, I-- W STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS SHALL O I-- BE IN ACCORDANCE WITH ASTM A 153. U F- O APA SHEATHING NOTE: UNSUPPORTED Z W _ E ' 24/16 SPAN RATED SHEATHING REQUIRES BLOCKING AT ALL PANEL EDGES AT HIP LOCATIONS. BLOCKING TO BE 2X4 ATTACHED AT EACH END LU WITH (3) 10d TOENAILS. U) 0 a FLOOR FRAMING NOTES GENERAL NOTES 1. FLOOR JOIST/TRUSS HANGERS SUPPLIED & ENGINEERED BY FLOOR JOIST/TRUSS CO. 2. REFER TO TRUSS MANU. DRAWINGS FOR TRUSS DESIGNATIONS. 3. GENERAL FLOORING FINISHES ARE ACCEPTABLE. IF LIGHTWEIGHT CONCRETE OR SELF LEVELING CONCRETE IS REQ. CONTACT E.O.R. ALONG WITH TRUSS CO. TO VERIFY FLOOR TRUSS DESIGN. NAILING SCHEDULE FLOOR SHEATHING TO BE 4" PLYWOOD OR OSB (U.N.0), WITH LONG DIMENSION PERPENDICULAR TO SUPPORT (FLOOR TRUSSES). NAILS: NAILS USED IN ALL FLOORING APPLICATIONS SHALL BE 8d, 8d RING OR SPIRAL SHANK, HAND OR GUN DRIVEN NAILS. GUN DRIVEN NAILS SHALL HAVE HEAD SIZE EQUIVALENT TO HAND DRIVEN NAILS, SPACING SHALL BE 6" ON EDGES AND 12" IN FIELD. NOTES: 1. FLOOR JOIST/ TRUSS MANUFACTURER SHALL COORDINATE LOCATIONS OF ALL MECHANICAL CHASES AND PLUMBING TO AVOID CONFLICT: 2. ALL JOIST TO JOIST OR TRUSS TO TRUSS CONNECTIONS SHALL BE SPECIFIED BY THE MANUFACTURER. 3. G.C./BUILDER SEE ARCHITECTURAL DRAWINGS FOR ROUGH OPENING LOCATIONS AND ADDITIONAL INFORMATION REQ. FOR DOOR AND WINDOW INSTALLATION ALONG WITH DIMENSIONS NOT SHOWN HERE. Z 0 O Q Z_ Z 0 00 Q N z W I- F4- W O W O ~ cl U 00 o [Lr?O 1 O O z 2 Z 0 m o V _j(1)OC T W >'-w0 0 Fa-0E- ry tY m STRUCTURAL ENG: RMG J Q DRAFTING: F- z STRUCT: JV w MQC CHECK: CC JOB No. TM - 2170194 NOTES & CONNECTOR LEGEND = SCALE: AS INDICATED DATE 04/12/2017 S4,1 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. NOT FA RTl In TO C All RFI C)\A11A// CA C`TI In T/\ t�f1A1 I ICI OVV \ICI VV1AI/ ;PER A. STUD TO CMU BELOW J/ (2) MSTAM24 STRAPS ER DETAIL WF02/SD6 IN STANDARD 2ND FLOOR FRAMING NOTES: 1. ALL EXTERIOR WALLS, LESS OPENINGS, ARE CONSIDERED SHEAR WALLS. U.N.O. ATTACH SHEATHING PER NAILING SCHEDULE, 2. AT ALL WINDOW/ DOOR OPENINGS @ 2ND FLOOR, CONTRACTOR TO FOLLOW THE DETAILS INDICATED BELOW" OPENING SITTING ON MASONRY- WS06/SD5 (STRAPS SHOWN ARE ONLY REQUIRED WHEN CALLED OUT ON PLANS OR SHEATHING IS NOT CONTINUOUS) OPENING SITTING ON WOOD BEAM- WS07/SD5 (STRAPS SHOWN ARE ONLY REQUIRED WHEN CALLED OUT ON PLANS OR SHEATHING IS NOT CONTINUOUS) 3. AT ALL CORNERS, CONTRACTOR TO FOLLOW WS09/SD5 U.N.O. WALL LEGEND = 10'-0" T.O.M. = I V-0" T.O.M. = 12'-0" T.O.M. = INTERIOR/EXTERIOR BEARING WALLS VERIFY HGT. W/ ARCHITECTURAL PLAN U.N.O. EXTERIOR FRAME WALL SCHEDULE (TAYLOR MORRISON) WALLS WITH PLASTER OR STUCCO FINISHES WALL HEIGHT STUD & SPECIES SPACING INTERIOR ZONE SPACING END ZONE 81-011 2x4 SPF #142 16" O.C. MAX 16" O.C. MAX 91-011 2x4 SPF #142 16" O.C. MAX 16" O.C. MAX 9'-4" 2x4 SPF #142 16" O.C. MAX 16" O.C. MAX 101-01, 2x4 SPF #142 16" O.C. MAX 12" O.C. MAX EXTERIOR FRAME WALL NOTES 1. 2x4 WALL STUDS WITHIN 5 FT OF EACH CORNER ARE CONSIDERED TO BE WITHIN THE WALL END ZONE. SEE CHART ABOVE FOR REQUIRED STUD SPACING, 2. SEE DETAIL WF10/SD4 FOR REQUIRED WALL SHEATHING THICKNESS & NAILING PATTERN. 2.1. NOTE: CONTRACTOR TO TAKE CARE AND NOT OVER DRIVE NAILS. IF NAILS ARE OVERDRIVEN, THE ENTIRE SHEET OF SHEATHING IS TO BE REMOVED AND REPLACED. IF MORE THAN 50% OF THE SHEATHING IS OVERDRIVEN, CONTACT FOR FOR REVIEW OF EXTERIOR STUDS 3. IF WALL IS FRAMED WITH 2x6 STUDS OR LARGER, STUDS ARE TO BE MIN. SPF #142 @ 16" O.C. U.N.O. ON FRAMING PLANS 4. SYP #2 STUDS MAY BE SUBSTITUTED FOR SPF #142 STUDS ONLY. 5. IF EXT. FRAME WALL IS NOT SUPPORTING PLASTER OR STUCCO FINISHES, FRAMER IS TO FOLLOW CHART ABOVE U.N.O. Lu Q� zo w w tY �t 0 N z O 1-- z op �n 00- W o U U U) (D LU z C) 0 J m Q 0 0 LL W W O z ty 1Ljj 811114"', 00 ULTIMATE WIND SPEED: 139 MPH EXPOSURE: B Z /�nn � z ~ ° R11 H V Z UOQ�0 dd R15 -j LU J v)WzWq 0 0 <000— I... U) Imo- z, Z z W o J06 R16 H2x8 _ QQcnZz E U u0 2 R17 � � � z�F-�F_ J05 > J �-�- Z U N Q R18 Q �' O 0 A � O I- O 0 J04 R 19 U Q Uj �-* — H2x6 z W = 3 Q)� C) C) o C) R20 U) O 3 d J 04 J 04 (D z ra alu - — H2x6 Q O M C0 co Cl)M M M C)y�OQ CD Z 0 �3 W H- Q 00 N W ~ I- Z -j 0 ui OW —j r �ci�LLI O 01 LU Z c? 0 Q �U)� U) >- W O W0H0. D 0 0_ W I-- STRUCTURAL ENG: RMG Q DRAFTING: P z W -STRUCT: iv QQC CHECK: CC JOB No. TM - 2170194 SCALE: AS INDICATED ~ DATE: 04/12/2017 ROOF ERAMING PLAN.S4.2 E. SEE PAGE S4.1 FOR NOTES AND CONNECTOR LEGEND COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. CONTRACTOR TO VERIFY THE GROUT IS LEVEL WITH TOP OF BLOCK FOR PROPER TRUSS/ FLOOR SYSTEM BEARING (MIN 3") z Na LL w n F_ r 0 w r a z O U) ° AT CORNERS PRECAST "U" PROVIDE LINTEL W/ 3000 STANDARD #5 psi CONC. PER HOOK BAR. LAP LINTEL PLAN. IF OTHER BARS INTO REBAR IS CORNER AS REQ'D INDICATED IN LINTEL, #5 TO BE.. HOOKED INTO SIDE VERTICALS ' °d ° Q METAL LATH OR WIRE SCREEN OVER COURSES NOT REQ'D TO BE FILLED. (SHEET METAL & PAPER FELT PROHIBITED) HOOK PER MD08 4 4 o d AII d ZBOTTOM STEEL IN LINTEL IF I 11 ° INDICATE - SHOULD HOOK INTO VERTICAL CELLS PER MD08 d ROUGH OPENING PER PLAN � ° d d ° W O LL z a w w U) d d° a' ` d 4 °. ° d d -SHEAR WALL AT OPENING TYPI AL SHEAR WALL SEGMENT d q. 4 4 d ° TYPICAL MASONRY CONSTRUCTION LINTEL W/ TRANSOM DETAIL SCALE: 3/4" = T-0" SEE DOWEL PLAN FOR FILLED CELL INFO. MIN. (1) IS REQ'D ON EITHER SIDE U.N.O. (2) 2X8 SYP#2 P.T. HEADER TURNED SIDEWAYS. ATTACH TO MASONRY WALL W/ SIMPSON HU28-2 HANGER @ EA. END. W/ (14) 1/4" x 2-3/4" TAPCONS TO MASONRY & (6) 10d NAILS TO HEADER SCALE: 3/4" = T-0" REQ'D LAP SPLICE, EMBEDMENT, AND HOOKED REINF. STEEL (INCHES) GRADE 40 GRADE 60 BAR SIZE BEND 0 LENGTH LAP SPLICE BEND O LENGTH LAP SPLICE „7r' "D" B " „ #3 1 7/8 41B/4 21/4 4 /4 9 1/4 8 #4 2 1 /2 5 5/8 9 1 /2 20 3 5 5/8 12 1 /2 24 #5 3 1 /8 7 11 3/4 25 3 3/4 7 15 1 /2 30 #6 3 3/4 8 1/16 14 30 4 1/2 8 1/16 18 1/2 36 #7 4 3/8 9 13, 16 1 /2 35 5 1 /4 9 13/16 21 3/4 42 I LAP SPLICE EMBEDDED 1 A_D_0'8 REBAR SPLICE DETAIL SCALE• 3/4" - 1' 0" PRECAST LINTEL LOAD TABLE GENERAL CONCRETE LINTEL SCHEDULE LOADS LISTED BELOW HAVE BEEN CALCULATED OR COMPILED FROM DATA FROM THE FOLLOWING APPROVED LINTEL MANUFACTURERS: APPROVED MAN. CAST-CRETE, QUALITY PRECAST CO., AND LOTT'S CONCRETE CASTE-CRETE, QUALITY, AND LOTTS W STANDARD LINTELS STANDARD LINTEL NOTES w o CLEAR OPENING 8 UNFILLED 8F8-1 B / 8F8-0B 8F16-1 B / 8F16-0B 8F24-1 B / 8F24-0B 8F32-1 B / 8F32-06 p V-6" 2231 3069 / 3069 6113 / 6113 8974 / 8974 10000 / 10000 U)1. AREAS OF BLOCK ABV. MASONRY OPENINGS ARE TO BE GROUTED SOLID TO TIE BEAM. 12. (1) #5 REBAR IN TIE BEAM iS TO BE CONT. THRUOUT INCLUDING ABV. MASONRY OPENINGS. U.N.C. LU 2'-2" 1783 _ 3069 / 3069 6113 / 5163 8974 / 8054 10000 / 10000 2'-8" 1343 _ 2693 / 2561 - 6113 / 3820 8974 / 5961 10000 / 8107 3. ALL STANDARD LINTELS TO HAVE MIN. 4" BEARING EA. END. ALL RECESSED LINTELS TO HAVE MIN. T-2" _ _ 1217 2165 / 1969 6113 / 2931 8672 / 4576 10000 / 6224 8" BEARING EA. END o T-4" 1006 1663 / 1349 5365 / 1999 7342 / 3123 10000 / 4249 4'-0" 860 -- 1651 / 1349 5365 / 1999 7342 / 3123 10000 / 4249 4• LINTEL MIN. DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF DEEPER LINTEL INSTALLED THAN 4'-6" 710 1423 / 1105 4360 / 1631 6036 / 2549 8328 / 3470 INDICATED ON PLAN, THE STRENGTH OF THE LINTEL INCREASES AND IS APPROVED WITHOUT O — - --- - ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT FOR FOR APPROVAL. H z 5'-2" 570 1232 / 1232 3480 / 2580 8360 / 3586 8825 / 4592 0 0 6'-2" 488 991 / 991 2661 / 2143 5681 / 2698 6472 / 3685 5. (*) ANY LINTEL DEEPER THAN 32" HAS BEEN VERIFIED TO WORK AS A MIN. 32" FOR THE LOAD w 7'-O" 416 752 / 699 1843 / 1625 3486 / 2602 6390 / 3302 CONDITIONS. ANY LINTEL GREATER THAN 32" HAS A GREATER CAPACITY AND THEREFORE IS 8'-0" 354 726 / 699 1843 / 1625 3486 / 2255 6205 / 2885 ADEQUATE FOR THE LOADS: LIJ 9'-2" 315 618 / 535 1533 / 1247 2781 / 1946 4754 / 2489 6. G.C. TO VERIFY ALL LINTEL DIMS IN WITH WINDOW R.O. SPECIFICATIONS ON PLAN. DIMS O 0 10' 0" 292 567 / 454 1366 / 1277 2423 / 1770 4006 / 2263 SHOWN ON LINTEL PLAN ARE CLEAR SPAN AND USED TO VERIFY DESIGN OF LINTEL ONLY, VERIFY 0 W 10' 8" 277 492 / 352 1254 / 1132 2193 / 1567 3552 / 2003 WITH WINDOW/DOOR SUPPLIER SPECIFICATIONS AND COORDINATE WITH FOR AS REQ'D. z 11' 2" 255 471 / 352 1075 / 1075 1838 / 1567 2883 / 2003 p - --- — - — -- 7. LINTELS SHOULD BE SHORED UP DURING CONSTRUCTION AS REQUIRED PER THE LINTEL 12' 0' 239 418 / 297 1075 / 1045 1838 / 1446 2883 / 1848 SUPPLIER SPECS. MCD IS NOT RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS 12'-8" 0 369 / 261 1002 / 984 1697 / 1361 2630 / 1738 m 13 4' 0 328/0 1234/0 1779/0 2662/0 14'-0" 0 292 / 0 1160 / 0 1660 / 0 2439 / 0 16-0" 0 284 / 0 950 / 0 1379 / 0 1997 / 0 O MATERIALS J - 18'-0" 0 211 / 0 750 / 0 1177 / 0 1676 / 0 LL 18'-8" _ 0 142 / 0 598 / 0 1114 / 0 1468 / 0 1. fc PRECAST LINTELS = 3500 PSI. W - — 20'-0" 0 180 / 0 598 / 0 1024 / 0 1441 / 0 I" ry _ _ _. ___ ___ __� 2. f'c PRESTRESSED LINTELS = 6000 psi. 20'-8" 0 145 / 0 550 / 0 981 / 0 1376 / 0 3. GROUTED PER ASTM C476 fg = 3000 psi W/ MAXIMUM 3/8" AGGREGATE AND 8" TO 11" SLUMP. O - - --- -- 22'-8" 0 110 / 0 450 / 0 824 / 0 1147 / 0 u) - -� ___----- — 4. CONCRETE MASONRY UNITS (CMU) PER ASTM C90 W/ MINIMUM NET AREA COMPRESSIVE Z RECESSED LINTELS -FILLED STRENGTH = 1900 PSI, 0 1tiIlllIyA Uj °) CLEAR OPENING 8R6-1B/8R6-OB 8R14-1B/8R14-0B _ 8R22-1B/8R22=0B L7 ®r� r�� co _ 5. REBAR PER ASTM A615 GRADE 60. PRESTRESSING STRAND PER ASTM A416 GRADE - ®®` ®�d® a 2 -4" 1694 / 1694 „ 3725 / 3280 5499 / 5421 —00 % �� �® 2'-8" 1425 / 1425 3343 / 3280 4933 / 4933 6. 270 LOW RELAXATION. 7/32 WIRE PER ASTM A510. `+� °.®®p°®®�°°®°°®°�/fj ®°sue Y T-0° _ 1230 / 1230 2769 / 2769 4085 / 4085 ®®°®ki ®°��� m J z 3-4" 1081 / 920 2769 / 1716 4085 /2839 LINTEL DESIGNATION SCHEDULE ° �1 OF ®2 _� a 4 4" 846 / 833 -- 2121 / 1716 3127 / 2839 _ � "" 0 _j 5 -4" 664 / 572 _ 1761-/ 1761 2595 / 2595 MARK LINTEL F = FILLED WITH GROUT / p° w Q -- U = UNFILLED R = RECESSED ?�''`® � Q 6'-4" 526 / 434.__ _ ._ _1539 / 1539 — 1329 / 2267 — REQUIREMENTS .ter QUANTITY OF #5 REBAR @ Cay,® >- O 7 4 480 / 322 1334 / 1334 1964 / 1552 t�% _-_8 4' — 415 / 235 1152 / 1152 1694 / 1552 O 8RF6-1B/1T BOTTOM OF LINTEL CAVITY ®�®® i PLL�® Via® ap 8 F1 6-1 B/1 T s 8F8-1 B/1 T _ '®/061 1Ia QUANTITY OF #5 REBAR AT TOP � 1) FOR HEADER DEPTHS DEEPER THAN 32", USE VALUES FOR 32" DEEP HEADER W - 2) FOR HEADER DEPTHS NOT LISTED ON CHART, USE THE VALUES FOR THE NEXT DEPTH DOWN. cO 8RF14-1B/1T NOMINAL HEIGHT 0° NOMINAL WIDTH 8F16-1B/1T ' O O TYPE DESIGNATION o 8RF14-0B/1T z ti I°'�; F 8F16-0B/1T 1-1/2" CLEAR rSi Oc 8F20-1B/1T LU ¢ cL O REQ'D ¢ x c r--.O x #5 REBAR AT TOP MIN. 1 1 O 8F20-OB/1T U U Ur� ¢ Q C.M.U. O 8RF22-1B/1T � ° GROUT O n z #5 REBAR AT OF LINTEL K 8F24-1 B/1 T t- z O co CAVITY Q r BOTTOM REINFORCING PROVIDED D O 8RF22-OB/1T 7-5/8" A U IN LINTEL (VARIES) p! M O 8" NOMINAL WIDTH 8F24-0B/1T a N 8RF30-1B/1T FILLED 0 O 8F32-1B/1T 1-1/2" CLEAR O 8RF30-0B/1T Q Lj O#5 REBAR AT TOP MIN. (1) REQ'D 0 z s 8F32 -0B/1T Q Q C.M.U. < (D r- U) o U o O W J��~ 0 8F38 -1 B/1T z Z 0 z w M E Ln O z O 06 �zU)u �' 0 O 8F12-1B/1T - Zc> BOTTOM REINFORCING PROVIDED Q z 0 0 p (ui 5 o 0 8F40 -0B/1T '�-�� U .� z z � 7-5/8" ACTUAL IN LINTEL (VARIES) O U) w z ,� c 0 8F8 -0B/1T 8" NOMINAL WIDTH = LL!Q 0 o d 0 x UNFILLED .I z z=� w o O W 0 WQWoO SAFE LOAD TABLE NOTES w 1-- ° Q r=NOT ES BASED ON MINIMUM 4" NOMINAL BEARING. EXCEPTION: SAFE LOADS FOR UNFILLED z J LL Z Z O w N Q UST BE REDUCED BY 20% IF BEARING LENGTH IS LESS THAN 6-1/2". SAFE LOADS FOR ALL p L... J O U D LINTELS BASED ON 4" NOMINAL BEARING. ATED. U .ADS ARE TOTAL SUPERIMPOSED ALLOWABLE LOAD ON THE SECTION SPECIFIED. ¢ W 4. SAFE LOADS BASED ON GRADE 40, GRADE 60 MAY BE USED WITHOUT WRITTEN APPROVAL FROM FOR z = 5. ADDITIONAL LATERAL LOAD CAPACITY CAN BE OBTAINED BY THE DESIGNER BY PROVIDINGw -Y--�— ADDIONAL REINFORCED MASONRY ABOVE THE PRECAST LINTEL. U) O 6. ONE #7 REBAR MAY BE SUBSTITUTED FOR TWO #5 REBARS IN 8" LINTELS ONLY. 7. THE DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE SAFE LOAD TABLES BY CALCULATING THE MAXIMUM RESISTING MOMENT AND SHEAR AT D-AWAY FROM THE FACE OF z_ SUPPORT. C) 8. FOR COMPOSITE LINTEL HEIGHTS NOT SHOWN, USE SAFE LOAD FROM NEXT LOWER HGT. O UH 1 9. ALL SAFE LOADS IN UNITS OF POUNDS PER LINEAR FOOT. p 0 Lu 00 �1 T_ Q N z W F- F- Z -O 16'-0" 00 Y F_ t� 0 o 0 O 9 �Om o U � co W Uu �- W O — �p �0..I=— F- W STRUCTURAL ENG: RMG J ¢ DRAFTING: z -STRUCT: JV w - 12 QC CHECK: CC r JOB No. TM - 2170194 SCALE: AS INDICATED F_DATE: 04/12/2017 LINTEL PLAN 1 /8"=1'-0" S 5 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. STANDARD 90' HOOK C STANDARD 180' HOOK #3=2%2 #4=2%2' #5=2%2 #6=3" #7 = 3 Y2" ELEV. A TYPICAL TRUSS ANCHOR PER PLAN PROVIDE SCREEN WHEN BLOCK BELOW IS NOT REQUIRED TO BE FILLED STANDARD 90 DEGREE HOOK TYP. BOND BEAM 8" x 8" x 16" K.O. LINTEL BLOCK FILL w/ 3000 psi CONC. w/ (1) #5 DIA. REBAR �- STD. 90 DEGREE ANGLE 3000 psi CONC. w/ (1) #5 DIA. REBAR 8" x 8" x 16" CMU U.N.O. INDICATES FILLED CELL FROM FTG. TO TIE BEAM w/ (1) #5 BAR W/ 3000 psi CONC. SEE MD08 FOR LAP INFO. PROVIDE CLEAN OUT OPENING @ GROUT FILLED CELL AND REBAR (TYP). MORTAR JOINTS SHOULD NOT BE CUT SEE FOUNDATION FOR FOOTING 9'-6" _ 8'-2" (1) #5 FROM FTG, TO TIE BEAM SPLICE TO i (1) #5 FROM FTG. TO IF BRIG, WALL ABOVE- - HOLD BRIG WALL BACK 2x BRIG WALL PER 2x BRIG WALL PER Q H TIE BEAM SPLICE TO 1/2" J-BOLT W/ MIN. 6' SO GYP FINISH IS PLAN AND BEARING PLAN AND BEARING ell BE MIN. 25" GROUT I' BE MIN. 25" GROUT PAST DEEPEST STEP FLUSH w/ FOUNDATION WALL SCHEDULE WALL SCHEDULE Z LU CELL SOLID CELL SOLID �I. co REQ'D MIN 4" BELOW 0 MASONRY WALL I I MASONRY WALL II W CONC. SLAB PER (1) #5 CONT. w/ 1-1/2" i SEE PLAN 41 a FOUNDATION PLAN COVER TYP. SEE PLAN 1-1/2" COVER TYP. CONC, SLAB PER w > FOUNDATION PLAN 2 1/4 CONC. SLAB PER CONCRETE SLAB PER I CONCRETE SLAB PER II z CONCRETE SLAB PER w FOUNDATION PLAN FOUNDATION PLAN I I^ FOUNDATION PLAN 4 z 2x PT SILL PLATE 2x P.T. SILL PLATE o w FOUNDATION PLAN � � 4 � Q `. VARIES w w a. n' a �— m U7 ° > a; d, d d d .: ! d + a , _ ^ d a . e . ' a • ., O SEE PLAN I a s a II . <. w d a li a I•-- Z d. ° .d ��, n a I ° Ob d r] ° n Wm I d W O _ - v 'r `a.. ,r' ,M1 _ d p.�, O t1 „y _ _ a = _ _ I _• . �u - " - ...- .. I........ d d GRADE J w GRADE —I I o a „1 z� d _ ; I I---III---.III-- �• a _�I I I=1�1 I III-1 w- ---"-I I a — ,.,u .1 , -.. ,.,- 45° o ,..... ._L.,....-.-- ^ :n "r „1 ., . a .d - op -- I ° _-__I I a ,p - — I III I . a I ___. L ..-.... d ° __ a III ...., (�, ..-..... — _ z _ _ ---- I_ . — -- - I 1 III I I L-- _f l I_:-._.: I I� _ — _ III_= — - __...-.-. IT I I - FEE-] - -- - — I I-1 I Imo' o _ I I _.- -- I �- I I --III 0 °� � — _ a pI_ _ II - I I ...I I l I I _ v, > -1 : I I :- . _ I ► L-III _ILL. _I I I_ I c� W III-:.mII_ a �, !IIIII IL III 8 8 (2) #5 BARS CONT. (2) #5 BARS CONT. 16" w 1 .� ` I I = III CLEAN COMPACTED W/ 3" COVER TYP. 3I' COVER ` CLEAN COMPACTED W/ 3" COVER TYP. 13`' COVER FILL @ 95% STANDARD CLEAN COMPACTED o (2) #5 BARS CONT. w/ 3" CLEAN COMPACTED (2) #5 BARS CONT. w/ 3" CLEAN COMPACTED m FILL @ 95% STANDARD DENSITY FILL @ 95% STANDARD U 8 8 FILL @ 95 /o STANDARD FILL @ 95% STANDARD 1'-4" COVER TYP.; AT COVER TYP.; AT DENSITY 1 -4 DENSITY �' DENSITY DENSITYIlk Q (2) #5 BARS CONT. w/ 3" 2-STORY COND. (3) #5 2-STORY COND. (3) #5 0 COVER TYP.; AT CLEAN COMPACTED BARS REQ'D & FTG TO BARS REQ'D & FTG TO WHERE 2ND STORY OCCURS, FTG WHERE 2ND STORY OCCURS, FTG 2-STORY COND. (3) #5 FILL @ 95% STANDARD BE 20" WIDE BE 20" WIDE SHALL BE 1'-4" WIDE w/(3) #5 BARS BARS REQ'D & FTG TO w SHALL BE 1'-4" WIDE w/(3) #5 BARS DENSITY w W BE 20" WIDE tL O FO TYPICAL EXTERIOR FOOTING AFO,�eTYPICAL GARAGE CURB FOOTING fiFO3� NON -BEARING SLAB STEP DOWN #FO�DOUBLE STEP FOOTING fiFO BEARING SLAB STEP DOWN fiFOkFOOTING AT INTERIOR BEARING z r�asic� w 3/4"=1'-0'' 3/4"=V-0" 3/4"=1'-0" 3/4"=V-0" 3/4"=1'-0" 3/4"=1'-0" ®ease®� ////®�®® oo OPT. MASONRYC `Z` �, ® ® ¢vim @ ELEV. 0'-0" w/ (1) #5 VERIFY W/ DETAILS FOR REQ'D VERIFY W/ DETAILS FOR REQ'D k Z ' I CONT. BAR STEEL AT 2 STORY LOCATIONS STEEL AT 2 STORY LOCATIONS U ®` �?S - "4 0 SLOPED GROUT TO . p p.` w 4� DRAIN MASONRY WALL -__� - •®® °� �• `,® °`� Q OPTIONAL CURB BY II BUILDER MIN. 24" BEFORE I ° I r' SEE PLAN I d�•®• �• e ?- .•®.®®®®® o OO I I z CONC. SLAB PER 8"x12" THICKENED ANOTHER STEP I a d r. - ®!� PR ee CONC. SLAB PER (1) #5 FROM FTG. TO � ®®®® �C w g O I SLOPE FOUNDATION PLAN TIE BEAM MIN. 25 ?,, //®®►i8!!IA®®®® CONC. SLAB PER FOUNDATION PLAN SLAB w/ 1 #5 CONT. 8' a „ #5 CONT. PER MFG SPLICE GROUT CELL cn FOUNDATION PLAN w/ 3 COVER TYP. I �^ Ilan REINFORCEMENT SEE SOLID PER PLANS J a r GRADE o 1 4I I (L n I FOUNDATION PLAN q'. a FOR QUANTITY -- d C.) cn tl 1 , _ r G , I'. O °- co THRESHOLD PER MFG U I � $, d " a d _.... __._ _-� . d. - #5 x 25' x 25 CORNER d d ° ° . a a� a I L—III—I I I-_„ L I_ a a - y w BAR, ONE FOR EA. _ ° Q"/ N , ., a I � — —� �, _ w d .-..._-. _III °'° _° - ° HORIZONTAL U - �. _ .._...._,.------` CONC. SLAB PER w -) I -I r----. .. _ I I I I .- d ,`_._,��-__���__._ a, _III-- I _:8' - __._' AI REBAR TYP. U.N.O. -I _ _ 4 I I Il,I- I_I_...-;I - �-.r---_ °- ,� ,,, I„ ,: ..... ;� "' .� ' FOUNDATION PLAN I I I -. .__.._ ' _ _ _., L...e_.I ---I I 1 III__-L I - I w ° _ - - t� �o :a. _— — _ III L — a w o = w _ _ _III .III --III -. -I w - -°- -� - .. _' .,,, I I I _ I I I I Q O ° — I� III I I _ _ �. _,__ . ......... . .._. i- _. .r .1 (2) #5 BARS CONT. - w III- I I I,_. I I I..,,,.-. I I_, L _-1 _ „ U ° SLOPE W/ 3" COVER TYP,; @ 1'-4" U _ __. .-. ) #5 CONT. w/ 3 _— 2-STORY CONDITION w 0 w (2) #5 CONT. w/ 3 I - ( 16" MIN. i.. (L COVER TYP. PER MFGSLOPEEXT. (3) #5 BARS w/ 20 O e' 1'-4' (2) #5 BARS CONT. = OR GRADE 1/4PER SURFACE WIDE FOOTING CLEAN COMPACTED 0 I MIN. 25" LAP SPLICE W/ 3" COVER TYP. CLEAN COMPACTED COVER TYP. ..... III III III-..-,. (2) #5 BENT BARS w/ FOOT AWAY FROM '� FILL @ 95% STANDARD C7, WHERE 2ND STORY OCCURS, FTG FILL @ 95% STANDARD BUILDING >O Z SHALL BE 1'-4" WIDE w/(3) #5 BARS DENSITY ELASTOMERIC JOINT DENSITY _ - FILLER Q _ 4. ui FOOTING @ SHOWER AT MASONRY F08 THICKENED EDGE Il M TYPICAL STEP FOOTING DETAIL AF10 TYPICAL CORNER BAR DETAIL (TOP VIEW) �Fl EXTERIOR DOOR POURED SILL F1 FOOTING AT INTERIOR BEARING WITH CMU 3/4"=1'-0" 3/4"=1'-0" 3/4"=V-0" 3/4"=1'-0" 3/4"=1'-0" 3/4"=1'-0" U 0 J #5 DOWEL W/ MIN. 6" #5 CONTINUOUS ANCHOR PER BRG - � z WALL SCHEDULE. IF FILLED CELL PER PLAN CONC. SLAB PER EMBED. INTO MAIN U) WOOD POST PER PLAN ---�CONC. SLAB PER CURB REQ. ANCHOR to �'` a � FOR SIZE AND BASE FOUNDATION PLAN FOUNDATION PLAN FOOTING W SIMPSON #4 BAR @ 48 O.G. W/ 2 1/4„ F- Lu U o CONNECTION EPDXY @ 12" O.C. MIN. 32" BEND INTO SHALL HAVE 6" MIN, w0 o J d w N _ _ _ 3/4" SLAB EMBED. BELOW z W O uj z i-- ``' �• o TOP COURSE TO BE CONCRETE STAIRS AS BOTTOM OF CURB. _p Q �2S � Z � � GARAGE rn cr N CHAIR BLOCKS. REQ'D PER GRADE W/ CONCRETE SLAB PER ~ � `� rn -t O � •� OPT CURB PER.. ¢ Z U 1= 0 O Co ENTIRE BASE TO BE MIN (1) #5 BAR @ PLAN MF04/SD1 0 Z P 0 w z FILLED SOLID NOSING ADD #5 CONT. WHEN -� _I in z Ix o TOP VIEW @ CORNER SEE ELEVATION „_ o = m STI RUPS REQUIRED 2 x P.T.,. SILL PLATE w O Q O p�� 0 a a z QZ)cnww E ZIt- I- z CMU BASE w/ (1) #5 ° ., -- . r+ a _ , SEE �' II F- O W a w Z O GARAGE WALL VERTICAL @ EACH _ • - _ - PLAN I I _ U u- '� O z CORNER. SEE FLR. __ ' Q BEYOND _ --.� L.L -- h � a 0 - „ ° h _ „ -- 4 g.a� .1 ° w Q F- � F- (I oo M #3 STIRRUPS @ 48 ,,. r - 0 I- � w N J CONC. SLAB PER PLAN FOR BASE SIZE a w m z :: :: "'. - oo z W Z p w N Q FOUNDATION I .da q . z (2) #5 DIA. BARS @ TOP _ I " z < (2) #5 DIA. BARS @ TOP. I �' . y - W a � X O.C. WHEN MONO ! I I:, <( J U DRIVEWAY BY -- _ w _j Q 1.4il . O I— O WHEN MONO DEPTH TI I �I I I ``. p WHEN MONO DEPTH u I , w I U) a z DEPTH EXCEEDS -- I -� PLAN w BUILDER- CONCRETE SEE FOUNDATION FOR a _ O 26 . IF LESS THAN -_ ° ° I•— OR PAVERS h.. I w j EXCEEDS 26 , IF h i- EXCEEDS 26', IF p PAD SIZE °' " w DEPTH < 26" THESE I L „I: °4 � ° DEPTH < 26" THESE I I ' v.. �. ~ 26" THESE 'III � Q I �L * ,� �.. �.�� "t�'� � 1-- 3/4' Ir c`' I d a ° w w BARS ARE NOT REQ'D _ _._.: I I BARS ARE NOT REQ'D .L-_._ «- - STIRRUPS ARE NOT .- I °° d .; U W CONC. SLAB OR w > w „ a' I GRADE „ GRA E REQ'D III„ i , d . ' r • ' -I •- - I. a LL1 _ °. 4 O W #3 STIRRUPS @ 48 __ III #3 STIRRUPS @ 48 __ - --... U. ° d PAVERS PER PLAN _ _ _ -- Z -i v . O.C. WHEN MONO III ...- I::, ::-I 1) 1- I . _ °'. wA '� ,-';,,,�;;<` I U O.C. WHEN MONO -.,_.....,..,__--- �. °.- a n , ...�,.. I._.:-:,:z ----- i--- z - LJ a = - I., _ :..III-- II .III °° I d a I a _ I .. J .4 - DEPTH EXCEEDS 26", DEPTH EXCEEDS 26", .I I I L..- -,_-. L._: ' . L -III--I-.._)- C #5 COVER W/ 3" MIN - „ I _ ..:..I I.—I.I:._- „ „ _ - CLEAN COMPACTED ..� , IF DEPTH < 26" THESE _......:: I IF DEPTH < 26" THESE _ I n �; -_ COVER ON CHAIRS O 20 x8 l.-——I--...--.. a 1_ _� i I - ...I I I _ -I ° -- BARS ARE NOT REQ D -• �- SEE PLAN FOR STAIR INFO, IF a THICKENED _ _-., __-- __ _._.....I � FILL @ 95% STANDARD (, `"y° I °'',.- ,, __._ BARS ARE NOT REQ'D 1._..::�.. _..- I _-_ __._ _. - - - - . .. s` �` :; ( I I --- CLEAN COMPACTED CONCRETE STAIRS ARE FORMED & EDGE W/ (2) #5 -i , DENSITY d d = La-"�'�' - 1 - ::I : ._"I I :.-:: CLEAN COMPACTED 2 #5 BARS CONT. W/ L,.L,-.. -...-____., CLEAN COMPACTED FILL @ 95% STANDARD POURED, PROVIDE (1) #5 @EACH STEP, V` CONTINUOUS 1'-8" 3" COVER TYP. CLEAN COMPACTED — ~--�`. d a '.' d (2) #5 BARS CONT. W/ 1,_4" FILL @ 95% STANDARD 3" COVER TYP. I I =:1 '4 -) ° FILL @ 95% STANDARD i_` _, _T 3 COVER TYP. --- -= FILL @ 95 /o STANDARD DENSITY &TERMITE DRILL AND EPDXY (2) 12" LONG #5 BARS Z DENSITY _ - __-.... ____, _,---_ � DENSITY DENSITY TREATED W/ 3" MIN COVER @ EA. END OF STAIRS O F13 THICKENED EDGE GARAGE DOOR F1 FOOTING @ ENTRY MASONRY COLUMN 011=20� DEEP MONOLITHIC FOOTING F21 DEEP MONOLITHIC FOOTING W/ STAIR fiF23 DEEP MONO INTERIOR STEP DOWN z Z ° @ — 3/4"=1'4" 3/4"=1'-0" 3/4"=V-0" 3/4„ =1'-0, 3/4 „_ -1, -0„ 3: 0 w H 00 11 H Q 00 TOP (2) #5 x 4T lE PVC OR SCH40 SLEEVE Q W CENTERED A Z _I PENETRATION = `0 LLJ _j 0) W 8" CMU - TOP (2) #5 x 4'-0" PVC OR SCH40 SLEEVE • .a _.. (� 0 - FINISH PER ELEV. CENTERED AT PIPE , CONC. SLAB PER „PENETRATION I T I FOUNDATION PLAN ui FINISH FLOOR ELEV. C.M.U. FINISH PER .-...- - . ,. _ : I (III z Z m FINISH FLOOR oo ..:.:::: ! d �' I_- I I w i- 0 O Z PENETRATING PIPE co ` PENETRATING PIPE -III-� (.. �- III .. III- - W >- W 0 GRADE SEE FDN PLAN FOR L ( 0 I� LL I� LOOP TIE (TYP.) o SIZ INF. I: :.: I _- l I _ I :: - -_L_ - I,. III III L. L PIPE PERPENDICULAR TO FND — --= T _:_ mS .. -� I , I-- I _- .. TOP (2) #5 x 4 -0 PVC SLEEVE MIN. I = FOOTING PER PLAN z 1_ -= - - ' I m_i III ---�-I CENTERED AT PIPE PVC OR SCH40 SLEEVE STRUCTURAL ENG RMG DIAMETER TO BE 2 I I,.,,: I_., PENETRATION CLEAN COMPACTED FOOTING PER PLAN Q DRAFTING: PIPE SIZES LARGER I w ..L..... I I --...III .. Z THAN THE FILL @ 95% STANDARD I -SEE FDN PLAN a 0 (SIDE VIEW DENSITY w STRUCT: JV PENETRATING PIPE \ -- I I FOR SIZE I I +_ ::� U - I .} ,, ,, ,::�� � ° � � QC CHECK: CC PVC SLEEVE ...._.III:,,:: .. � r. (FRONT VIEW I :: : I-- fI �,. R JOB No. TM-2170194 I I II SCALE: AS INDICATED PIPE VERTICAL THRU FDN III ( -I -- <,-a - I ~ DATE: 04/12/2017 _ TYPICAL FOUNDATION PENETRATIONS .III:_.. -.I 1::-NOT USED 3/4„„ PIPE PARALLEL TO FND SD1 _1 ,0 - COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited, 41.. w LU d d ' z ENTIRE COLUMN TO a BE GROUT FILLED w ' U.N.O. U) �4 � d G i l _ ., 4. PROVIDE STANDARD HOOK (1) #5 IN TIE BEAM (1) #5 BAR IN PRECAST LINTEL (2) #5's VERTICAL IN GROUT FILLED CELL f c (1) #5 VERTICAL IN E GROUT FILLED CELL (IF REQ'D PER PLAN) F i NOTE: SEE MD08 ON LINTEL PLAN FOR ADDIT'L REBAR INFO VERTICAL REINFORCEMENT DETAIL PRECAST LINTEL PER PLAN MASONRY WALL - SEE PLAN 2x8 W/ (2) 16d TOE NAILS EA. END 2x SPF CONT. BLOCKING ATTACH TO 7/16" OSB W/ (2) 8d NAILS 7/16" OSB EA. SIDE, W/ 6d NAILS @ 16" O.C. TO SIDE & TOP NAILER 2x BUCK PER MD04 THIS SHEET NOTE: CUT BACK 2x8 GARAGE BUCK DETAIL P.T. @ TOP TO ALLOW d. CONT. 2x4 BLOCKING AROUND CURVE. MIN. 2 TAPCON ANCHORS PFR 9YA ARCH WINDOW FRAMING DETAILS 3/4"=1'-0" PRE-ENGINEEF TRUSSES PER 24" 0, C. MAX. TYP. TRUSS TC CONNECTION I CONNECTION I EXT. SHEATHIP ATTACHED PE NAILING SCHE FROM TOP OF KNEEWALL TO OR SP2 CLIPS AND SP1 CLIP: BASE ARE REC 2x BLOCKING MIN 2x4 STUD O/C 2x P.T. PLATE 1/2" x 8" A.B. 01 HD@32"O.C. FROM EA. ENC ON BASE PLAT TOP KNOCK 0 COURSE W/ (1 CONT. �FlKNEEWALL ABOVE MASONRY WALL ARCH PER ELEV 2x6x12 P.T. CENTER BUCK 3/8" DIA. ANCHOR CENTERED GARAGE WALL BEYOND 2x6 P.T. BUCK EACH SIDE OF OPENING SEE PLAN FOF FRAMING INFC BLOCKING PE WALL SCHEDI (2) 2x TOP PLATE W/ (3) 12d END NAILS TO LAST STUD TYPICAL TIE BEAM w/ 3000 psi CONC. w/(1) #5 REBAR CONT. STD HOOK 2x PT STUD OR ALTERNATE 1x PT FURRING TO CMU W/ 2x FRAMING PER PLAN TYPICAL FILLED CELL w/ 3000 psi CONC. w/(1) #5 REBAR VERT. VERIFY w/ PLAN FOR REQ'D LOCATIONS WATERPROOFING BY BUILDER NOTE: THIS DETAIL APPLIES TO THE FOLLOWING CONDITIONS: (1) EXTERIOR FRAME WALL TO CMU (2) INTERIOR FRAME SHEAR WALL TO CMU (3) INTERIOR LOAD BEARING FRAME WALL TO CMU WALL V I CMU WALL PER PLAN (5) 3/8" DIA. J-BOLT W/ �ru 5-1/2" EMBED. AT EA. THREADED ROD PER (4) EQ. SPACED 2" TITEN HD ANCHORS w/ DOOR BRACKET, EA. PLANS. MIN. 6 FROM 3n" SIDE OF DOOR. END OF BRG. WALL/ MIN. 1 a EMBEDMENT FOR HOLLOW PROVIDE 1-1/2" x 3/16" MASONRY WALL I BLOCK OR 3 1/2" EMBEDMENT FOR SOLID THICK WASHER W/ EA. I .."" BLOCK. MAX. 6" FROM TOP AND BOTTOM ANCHOR. (1st BOLT TO OR 1/4" TAPCON W/ MIN. 2" EMBEDMENT 6" BE 8" MAX. ABV. CURB, BASE PLATE mI FROM TOP AND BOTTOM AND 12" O.C. REST EQ. SPACED CONNECTION PER BRG �; BETWEEN -24" O.C.) WALL SCHEDULE 1 /2"=1'-0" LINTEL (SEE PLAN) 7/16" O.S.B. EA. SIDE 2x BLK'G. TO O.S.B. (2) - 8d EACH END END VIEW w/ CMU HEADER (SEE PLAN 7/16" O.S.B. EA. SIDE ARCH PER ELEV _--- 2x BLK'G. TO O.S.B. (2) - 8d EACH END END VIEW w/ WOOD IF REQ'D, PROVIDE CLOSURE WALL w/ SINGLE TOP AND BASE PLATE w/ (2) 16d NAILS TO TRUSS. STUDS @ 24" O.C. & EXT. SHEATHING INSTALLED PER NAILING PATTERN CRICKET AS REQUIRED MAIN SPAN ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MASONRY WALL PER PLAN PT BASE PLATE BEARING/ SHEARWALL CONNECTION TO CMU 3/4"=1'-0" SEE TYPICAL HEADER RAMING DETAILS FOR �DDITONAL VFORMATION HEADER CAN BE :ITHER UPSET OR )OWNSET) !x W/ (2) 16d TOE NAILS EACH END 3) 16d COMMON JAILS (TYP.) 2x BUCK DETAIL SHEATHING PER PLAN TYP. TRUSS TO FRAME CONNECTION PER STD. CONNECTOR NOTES FRAME OUT TO BLOCK EDGE AS REQ'D (2) 2x TOP PLATE (2) 2x PLATE MIN. 2x4 SPF #2 KNEE �'- MIN. 2x4 SPF #2 KNEE WALL WITH STUDS @ WALL WITH STUDS @ !x4 SPF CONT. 16" O.C. W/ (2) 2x #2 SYP SEE PLAN 16" O.C. W/ STRUCTURAL FOR BEAM SIZE STRUCTURAL 3LOCKING ATTACH TO SHEATHING ON BOTH SHEATHING ON BOTH /16" OSB W/ (2) 8d SIDES FROM TOP OF SIDES FROM TOP OF JAILS WALL TO BOTTOM OF I BUILDER FRAME WALL TO BOTTOM OF '/16" OSB EACH SIDE, BEAM. ATTACHED PER RADIUS AS REQ'D BEAM. ATTACHED PER N/ 6d NAILS @ 16" O C NAILING SCHEDULE NAILING SCHEDULE FO SIDE & TOP NAILER OTHERWISE SP2 CLIPS >x BUCKS, AT TOP AND SP1 CLIPS AT BASE ARE REQUIRED fiF_0' KNEEWALL AT DOWNSET BEAM NAIL SCAB TO TOP IF A/C IS SUSPENDED CHORD WITH (4) 10d FROM TOP CHORD (2 NAILS 2x4 #2 SYP BLOCKINC ADD 2x4 VERTICAL REQ'D @ TOP CHORC SCAB IN EACH TRUSS ATTACHMENTS IF NO WEB IS PRESENT SUPPLIED BY A/C COMPANY (3) 10d NAILS TYPICAL AT EACH TRUSS 2x4 'X' BRACE ACROSS LENGTH OF SHEARWALL NAIL SCAB TO TOP 2x4 #2 SYP RAT RUN CHORD WITH (3) 10d TOP AND BOTTOM MI NAILS (2) BAYS PAST A/C LOCATION. MIN (3) BA 2x4 BLOCKING LAP W/ (2) 16d NAILS BETWEEN TRUSSES TO EACH TRUSS. TYF TOENAILED TO EACH SIDE DOUBLE TOP PLATE w/ 10d NAILS @ 4" O.C. STANDARD TRUSS - TRUSS PER PLAN BOTTOM CHORD DOUBLE TOP PLATE FRAMED WALL PER PLAN PERP. SHEARWALL CONNECTION TO TRUSS /T6011 A/C IN TRUSSES 3/4"=1'-0" 3/4"=1'-0" 3/4"=1'-0" J LLI PRE -CAST LINTEL PER PLAN ., z p w cn w v FASTEN PT 2x BUCK N TO MASONRY NOTES: z 1. 1x OR 2x PT BUCKS/NAILERS SHALL EXTEND BEYOND INT. FACE OF O WINDOW, FASTEN BUCK TO MASONRY W/ (2) ROW OF 1/4" TAPCONS 6 1=- z FROM ENDS AND 12" O.C. MAX. TAPCONS TO BE 1 1/2" MIN. FROM EDGE OF 0 0 BUCK. TAPCONS SHALL HAVE AT LEAST 1" PENETRATION INTO CMU. w 2. ADDITIONAL 2x WOOD BUCK MATERIAL MAY BE ADDED TO EXISTING 2x LO BUCKED OPENING, USE (3) ROWS OF 10d x 3" NAILS STAGGERED @ 12" Uj O.C. @ EACH SUCCESSIVE BUCK O C) 3. MIXING OF 1x AND 2x BUCKS SHALL BE PERMITTED FOR THE SAME U ( ) OPENING IF WINDOW MANUFACTURER AND PLAN REQUIREMENTS O W 0 P.T. BUCK PER DOOR (FASTENING) ARE MET 4. BUILDER SHALL FOLLOW DOOR/WINDOW MANUFACTURER'S WRITTEN J MANUFACTURER'S SPECIFICATIONS. SPECIFICATIONS, O J ww L� O 07 00 SHEATHING PER PLAN STRUCTURAL m °mm®�/ TYP. TRUSS TO FRAME SHEATHING 4 �;.�� Z CONNECTION PER TYP. TRUSS TO FRAME aalrl b STD. CONNECTOR CONNECTION PER o NOTES STD. CONNECTOR i/'� 07 ',,se , ®per p FRAME OUT TO BLOCK NOTES 4®e ® m ! �1®�, � EDGE AS REQ'D FRAME OUT TO BLOCK ® O EDGE ®®i�®® P ®®ee :x m U- (2) 2x TOP PLATE -� 1/2" x 8" ANCHOR BOLT a - OR TITEN HD @ 32" (2) 2x #2 SYP SEE PLAN 2 O (2) 2x #2 SYP SEE PLAN FOR BEAM SIZE (ONLY O O.C. & 6' FROM EACH U FOR BEAM SIZE � IF OPENING PROVIDED ATTACHMENT REQUIREMENTS SIZE TAPCONS SPACING # ROWS 2x4 3/16" x 3 1/2" 12" O.C. 1 3/16" x 3 1/2" " 2x8 3/16" x 3 1/2" 12" O.C. 2 END I PER PLAN) z co MIN. 2x4 SPF #2 KNEE 2x PT BOTTOM WALL w/ STUDS @ 16" «li PLATE O.C. w/ STRUCTURAL w o SHEATHING FROM O TOP OF WALL TO Q ° " PRECAST LINTEL OR BOTTOM OF WALL. U KNOCK OUT COURSE ATTACHED PER U- E NAILING SCHEDULE C �•" OTHERWISE SP2 CLIPS z,.' — MASONRY WALL • AT TOP AND SP1 CLIPS BUILDER FRAME '• AT BASE ARE REQ'D C) /^► RADIUS AS REQ'D KNEEWALL AT UPSET BEAM O _. C( GL1 LLI fiFO KNEEWALL OVER MASONRY WALL 3/4"=1'-0" 3/4"=1'-0" 0 rr ROOF SHEATHING 0 Z ATTACH PER NAILING J (D ti SCHEDULE U rn Cc) _� w C I-- 0 cN O O E STANDARD TRUSS O W Wz U) I rn C F- 1— (D 40��� c TOP CHORD VARIES U 0 Z U I= W z 00 O TRUSS WEBS NOT � ...J _I (n x z wooy SHOWN FOR CLARITY w :) Q O 0 coo PRE-ENG.TRUSS PER I=- < Z z� F- w W o PLAN, 24 O.C. MAX = Z Q Q w z p E 2x4 #2 SYP CROSS F- � w W O O BRACING (AT 45°) W/ ROOFING MATERIAL O 02 0 (3) 12d NAILS TO RAT PER ARCHS U U_ H N FF- RUNS. TYP EACH SIDE _ ,_, SEE FRAMING PLAN z J O O v N `C FOR CONNECTION 0 F"Uj CONDENSATE DISPOINFO LL p H C11 SUPPLIERAL BY A/C \ SEE ELEVATION U L TOP OF MASONRY <t U CONNECTION TO BE Z LIJ SUPPLIED BY A/C --- SEE ARCH PLANS FOR 0 U) COMPANY OVERHANG INFO U) O d (2) 2x4 #2 SYP 2 BLOCKING W/ SIMPSON RE, ELEV. Z A34 OR LUS24-2 EACH FOR O.H. END TYP. SINGLE TIE -BEAM Q W/ (1) #5 CONT. O GROUT SOLID r-) Q O z Z O w = F- 00 11 Q 00 CL DORMER FRAMING DETAIL NOTE. SEE ARCH ELEVATION FOR F rO CHIMNEY FRAMING DETAIL THING MUST BE APPLIED AND FASTENED TO BASE "- '— " SD2 1/4"=1'-0" NOTE: ROOF SHEATHING 3/4 -1 0 3/4 -1 0 TRUSS PER PLANS BEFORE DORMER FRAMING IS INSTALLED. COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. SIMPSON F , DIAGONAL TO BEAM SIMPSON HGA10 @ 48" O.C. SHEATHING NOT REQ'D TO BE CONT. @ THE TRANSITION FROM BEAM TO GABLE TRUSS BEAM PER PLAN SIMPSON I DIAGONAL PLATE SIMPSON HGA10 @ 48" O.C. NOTE: ALL GABLE BRACING IS TO BE SHEATHING NOT REQ'D SYP#2 OR BETTER TO BE CONT. @ THE TRANSITION FROM WALL TO GABLE TRUSS DOUBLE 2x TOP PLATE FASTEN SIDE WALL SHEATHING PER PLAN. (5) 16d NAILS BRACE TO BLOCKING EXT. SHEATHING; ATTACH PER PLAN BEAM CONNECTION FRAME WALL CONNECTION CONTRACTOR TO FIELD VERIFY WHICH CONDITION IS REQUIRED. CONTACT FOR FOR ADDITIONAL INFO AS REQ'D SIMPSON A23 @ EACH A35 DIAGONAL TO BRACE TO PLATE TRUSS BOT. CHORD 3 1/4" HOLD 1/2" J-BOLTS w/ PT 2x8 PLT., CANT. FOR WASHERS (MIN. 7" CLG. NAILING SURFACE EMBED) MIN. 6" FROM 2x4 SYP #2 BRACING @ EACH END AND 32" O.C. 24" O.C. FOR FALSE BM w MAX. ATTACHMENT w/ (3) 10d z z TOENAILS EA. END U) PROVIDE 16d NAILS z -' GABLE END TRUSS TO < 2x TOP PLATE TOLL PLT.@12" O.C. MAX. Uj U U GABLE END W/ 16d p m O NAILS @ 6" O.C. FRAMING FOR FALSE L CMU WALL OR LINTEL--------___.M. = @ 32" O.C. BEAM, IF REQ'D w/ (3) BELOWHGA10KT 10d NAILS @ EA. TRUSS BRACE TIE BEAM COURSE w/ (1) 2x4 STUDS @ 24" O.C. w/ #5 CONT. SINGLE BASE & TOP PLATE w/ PLYWOOD FALSE BM PER PLAN SHEATHING COVERING IF REQ'D CMU WALL CONNECTION CLEAR SPAN CONNECTION ***NOTE: REFER TO DETAIL GE02 THIS PAGE FOR GABLE BRACING*** GABLE END @ FLAT CEILING CONNECTIONS ROOF SHEATHING PER PLAN 2x4 OUTLOOKER @ 24" O.C. MAX. w/ (2) 16d END NAILS TO TRUSS TRUSS PER PLAN — NOTE: PROVIDE ADDIT'L BLOCKING AS REQ'D PER HIB-91 & TRUSS MANU.'S DRAWINGS; CEILING GYP. BD. IS NOT A DIAPHRAGM 3/4"=1'-0" 2x4 BLOCKING @ EA. - OUTLOOKER (MAX. ROOF SHEATHING SPAN 2'-0") w/ (2) 16d END NAILS EA. END VARIES I UX RAKED DOUBLE TOP PLATE CEILING NAILER AS - REQ D 2x8 #2 SPF STUDS @ 16" O.C. TYP. 2x8 #2 SYP PT BASE PLATE CMU WALL PER PLAN GABLE END @ VAULTED CEILING 3/4"=1'-0" W O 0 2'-0" MAX. 1'-9" MAX. 2x4 BLOCKS, (2)16d NAILS @ EA. END. BLOCK ADJ BAYS @ EA. DIAL. AS SHOWN. FASTEN ROOF SHEATHING TO BLOCKS W/ 8d NAILS @ 6" O.C. (4) BAYS MIN (1) BAY AFTER BRACE IS REQ'D) PROVIDE 2x4 BRACE TO EA. ADJ. DIAG. FASTEN TO DIAG. w/(2) 16d NAILS. GABLE BRACING @ 48" O.C. NOT REG'D 6' FROM EAVES GABLE BRACING CHART H GABLE BRACING + UP TO 4'-8" NO BRACE REQUIRED 4'-8" < H 6 T-0" (1) 2x4 BRACE 7'-0" < H b 9'-4" (2) 2x4 BRACE (SEE SECTION A -A) 9'-4" < H614'-0" STRONGBACK W/ (1) 2x4 BRACE 14'-0" < H:618'-8" STRONGBACK W/ (2) 2x4 BRACE 2x4 BRACE IF REQ'D WHERE O.H. IS > 1'-0", DROP GABLES w/ OUTLOOKERS @ 24" O.C. 1'-0" MAX CANT. O.H TO RUN BACK TO 1ST COMMON SEEE EELEV. LEV. FOR TRUSS WITH (3) 12d TOENAILS. O.H. SIZE CONNECT TO DROP GABLE WITH H2.5 CLIP. MAX 2'-0" O.H. \ \O SEE GABLE CONNECTION DETAIL FOR REQ'D CONNECTIONS 2x4 ATTACHED TO EA. - GABLE 2x4 BRACE WITH (2) 10d NAILS SEE CHART. 10d COMMON NAILS (1) A23 FROM @ 6" O.C. STRONGBACK TO DIAGONAL GABLE VERTICAL 2ND 2x4 BRACE IF REQ'D, SEE CHART A -A GABLE VERTICAL BRACING 2x6 GABLE END BRACING 3/4"=1'-0" 10d COMMON NAILS @ 8" O.C. 45° CONT. 2x4 2x4 DIAGONAL BRACE @ 48" O.C. TO 3RD BAY REQ'D w/ STRONGBACK, SEE CHART GABLE BRACING (+) SEE CHART STRONGBACK IF REQ'D PER CHART 2x4 BLOCKS, (2) 16d NAILS @ EA. END. BLOCK ADJ. BAYS C EA.DIAG. AS SHOW FASTEN ROOF SHEATHING TO BLOCKS w/8d NAILS @6"O.C. (5) 16d NAILS BRACE TO BLOCKING A A PROVIDE 2x4 BRACE GABLE END TO EA. ADJ. DIAG. SHEATHING FASTEN FASTEN TO DIAG.w/ PER PLAN. 16d NAILS. PROVIDE 2x BLOCKING FOR NAILING 2x4 BLOCKING (2) 12d (2)16d NAILS PLT. TO NAILS, TOENAILED @ STUD TOP & BOTTOM EACH END.AT 24" O.C. ROOF SHEATHING (TYP.) (END NAIL PLTS. PER PLAN TO STUD) TRUSS PER PLAN DTC CLIP, (2) 8d NAILS 2x FASCIA w (2) 16d INTO BLOCKING, (4) 8d END NAILS @ EA. 2x4 #2 SYP P.T. XNAILS INTO TOP PLATE OUTLOOKER BLOCKING @ 24" O.C. (2) 16d TOE NAILS SIMPSON H2.5(TYP.) W/(2)12d END NAILS BRACE TO LEDGER HOLD WALL 3-1/2" @ EACH END DOWN FOR DOUBLE TOP PLATE OUTLOOKER TRUSS PER PLAN 2x4 LEDGER W/ (2) 10d HEADER PER PLAN IF NAILS @EACH WEB REQ'D. MIN (1) JACK & TRUSS PER PLAN z EXTERIOR SHEATHING. ATTACH PER PLAN (1) KING STUD w/ SIMPS. w FROM TOP OF WALL LSTA18 HEADER TO w TO BOTTOM STUDS TYP. BASE w CONNECTION 2x8 #2 SPF STUDS AT SHEATHING PER PLAN _ 16" O.C. 1/2" x 8" J-BOLT @ 32" O.C. AND 6" FROM EA. 4 DTC CLIP, (2) 8d NAILS INTO BLOCKING, (2) MASONRY WALL OR — -" 2x8 #2 SYP PT. BASE END w/ NUT & WASHER MASONRY WALL OR 3/16" x 2 3/4" TAPCONS LINTEL SEE PLAN PLATE W/ 1/2" x 8" MSTAM-24 TYP. EA. LINTEL SEE PLAN IN IN CMU. OR SIMPSON ANCHOR BOLT OR TITEN HD @ 32" O.C. & SIDE OF EA. STUD. META16 6" FROM EACH END CENTERED BETWEEN FRAME WALL DETAILMU WALL SPLICE DETAIL STD CONDITION @ CMU VAULTED CONDITION @ CMU FOR REQ'D FLASHING TRUSS PER PLAN `1PSON DTC, (2) 8d ILS INTO BLOCKING, 8d NAILS TO TOP aT E USS PER PLAN 2x4 SYP #2 BLOCKING, @ 24" O.C. W/ (2) 12d END NAILS @ EACH END. TRUSS PER PLAN DTC CLIP, (2) 8d NAILS INTO BLOCKING, (2) 3/16" x 2 3/4" TAPCONS IN CMU. OR SIMPSON META16 AT 24" O.C. Q I— H Q z p SHEATHING PER PLAN 0 i CANT. O.H. _ :OR 0 /— WHERE O.H. IS > 1'-0", DROP END GABLE w/ z OUTLOOKERS @ 24" O Z O.C. TO RUN BACK TO p 1ST COMMON TRUSS WITH (3) 12d TOENAILS. � CONNECT TO DROP w GABLE WITH H2.5 CLIP. 0 O MAX 2'-0" D.H. U Z LLI C) 2x4 24 O.C. Q p END 0 THING FASTEN � LAN w > E AS REQ'D ui w O ION H10A DIAG. Z ___ ---- i v aLOCKING O Uj rn a 0 1118111ji/ Y o m0%t11 GABLE BRACING @ 48° _ PROVIDE 2x ��� FOR NAILING ®®o• °�®®•�� ®°®®� ��®® Qp V O.C. MAX. 45° FROM y U,, w Q HORIZONTAL (+/- 10°) BRACE NOT REQUIRED 6' FROM EAVES. - _-- — TRUSS PER PLAN 0: Z % O vo• ®': m - SEE PLAN FOR '✓� o° oo ~ * , IIA SUPPORT AND TIE ''® °•o.000•®° DOWN OF JACK . TRUSSES ��®/�' PROVIDE BLOCKING 0- �4p BETWEEN TRUSS BAYS 2 OU @ 48" O.C. FOR FIRST 3 BAYS SEE GABLE WALL PER PLAN 0 .' lip CONNECTION DETAIL (FRAME WALL SHOWN; z <FOR *z ; RE'D MAY ALSO BE co CD CONNECT ONS MASONRY) `- ***NOTE: GABLES SPANNING LESS THAN 8' DO NOT REQUIRE BRACING*** � '; � C � Q o U U LL z O��� O w GABLE END @ FLAT CEILING w/ BOSTON HIP w - 3/4"=1'-0" U Z (2) 2x TOP PLATE H U) SEE GE01/SD3 FOR 8d NAILS @ 4" O.C. < U o zi OUTLOOKER OR CONV. FRAME OR w < W -i -' °' ` . i HEADER PER PLAN; SHEATHING VALLEY TRUSSES PER Z 0 v� z � `Y' E SEE HEADER SCHEDULE & NOTES CANTILEVER PLAN O H W 06 L z U) P FOR ADDT'L INFO. 0 Z UO p z 3 SIMPSON LSTA12 OR O J N o SP4 CONNECTORS @ GABLE TRUSS O� V rn - 24"o.c. IF HEADER WITH _ 1-- ..-� o UPLIFT SPAN 4'-6" OR 4''„� Z Q j tw- z E MORE. EXT. SHEATHING; LL �/ 0 z 0 U `'� 2 ATTACH PER NAILING d 2x DOWNFRAME TO SCHED. W W Q Q DOOR AS REQ'D (2) 16d NAILS TO EA. z W J Z O w N Q COMMON TRUSS Q U I W 0� 0 W SIMPSON META16 @ `✓ 32" O.C. GABLE TRUSS MAIN SPAN ROOF z Ll.l 1/2" THREADED ROD TO MASONRY. AT TRUSS - p _ EA. SIDE OF HEADER WOOD WALL (n (CENTERED w/in TOP LOCATIONS USE UPLIFT CONNECTOR (n PLATE & 6" FROM JAMB LSTA18 OR MTS12 @ (SEE SCHEDULE) a STUDS) w/ MIN 7" 32" O.C. MASONRY WALL 2- EMBED. INTO SLAB SHOWN, SEE PLAN C0 ONLY REQ'D @ BRG FOR WOOD OR z WALL W/ UPLIFT MASONRY Q (GEO GABLE END AT VALLEY FRAMING O z Z W F-- 00 HEADER STUDS PER Q 00 HEADER SCHEDULE > N U.N.O. ON PLANS zz LJJ 0WOc� WUj . 0 40 I ATTACH JAMB STUDS pF�NG IIY 00 i0,0 I PER WF08/SD4 F- 0 V- 0 W cT o 0 Z ......�.� ..�.� W j. W 0 .�..� P.T BASE PLATE oWc 0 H 0. E— p � v 0_ p STRUCTURAL ENG: RMG JQ DRAFTING: z -STRUCT: JV W_ - © QC CHECK: CC W JOB No. TM - 2170194 SIMPSON MTS12 OR SCALE: AS INDICATED LSTA12 & (5) 8d NAILS DATE: 04/12/2017 @ EA. RAFTER TO PLT. FIELD FRAMED VALLEY DETAIL - NON —BEARING WALL CLIP DETAIL fiFO TYPICAL HEADER DETAIL 1 /2"=1'-0" 3/4"=1'-0.1 1 /2"=1'-0" SD3 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTH CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. 2x8 RIDGE BOARD 2x6 COLLAR TIE HALF WAY UP HEIGHT OF VALLEY. FASTEN w/ (5) 10d COMMON NAILS @ EACH END (TYP.) 2x6 RAFTER TO 2x8 RIDGE BOARD W/ A35 ON (1) SIDE OF RAFTER & A35 ON ADJ RAFTER TO OPP SIDE (AS SHOWN) 24's @ 24" O.C. MAX. FASTEN SYP OR SPF 2x6 (MIN.) PLATE THRU SHEATHING PER PLAN W/ 1/4"x4-1/2" SIMPSON SIDS SCREWS TO TOP CHORD OF EACH TRUSS BELOW FASTEN CONV. 2x VALLEY RAFTER FRAMING (OR PRE-ENG VALLEY TRUSSES) TO 2x PLATE WITH WALL SHEATHING PER LAY 2x4 BLOCKING PLAN LINTEL PER PLAN OVER THE TOP OF THE BOTTOM CHORD. 2x WALL, SEE PLAN .A ATTACH W/ (2) 10d - NAILS @ EACH TRUSS AT 24" O.C. STD CONDITION @ FRAME WALL BEARING CONDITION @ CMU WALL NOTE: PLATE LENGTHS MUST BE AT LEAST 8'-0" LONG. TYP. IL . IN TOP SPLICE @ - DOUBLE 2X4 TOP PLATE ATTACH 2x4 STUDS TO TOP PLATE W/ (3) 12d TOE -NAILS TYPICAL AT ALL LOCATION BOTTOM SPLICE OVER STUD PIPE OR DUCT W/ (2) 10d NAILS @ 3" O.C. — PENETRATION OF WITHIN 48" OF SPLICE MORE THAN 50% OF THEN (2) ROWS 10d NAILS TOP PLATE WIDTH @ 8" O.C. OTHERWISE INSTALL SIMPSON PSPN516Z W/ (12) 16d NAILS TYP. TOP & BOT. ATTACH 2x4 STUDS TO - (2) 10d NAILS @ 3" O.C. TOP PLATE W/ (3) 12d WITHIN 48" OF SPLICE TOE -NAILS TYPICAL AT THEN (2) ROWS 10d ALL LOCATION NAILS @ 8" O.C. OTHERWISE 2x4 WALL BEYOND AGAINST 2x8 STUDS 48„ ATTACHED PER Miy (WF08/SD3) ATTACH 2x8 STUDS TO TOP PLATE W/ (4) 12d , I TOE -NAILS TYPICAL I✓J AT ALL LOCATION TYPICAL TOP PLATE SPLICE @ BRG. WALL 2x�DBIL TOP PLATE BEYOND 2 MIN. 15/32" EXP 1 SHEATHING INSTALLED VERTICALLY. -- I- _1_�— IF_ II 6-- I I II II II II III -I-I--_11— I I II II II L-_--_----- II III I I 1 I WALL SHEATHING III III I II I SPLICE, SEE SPLICE DETAIL. MAX 1/8" III OPENING 11 I II II 1 E BETWEEN III 1 I 4 1 PANELS III 3T IIIII II1IIIIIIII IIIIII IIIIIII1III II1IIII1II IIIIIIIIIIIIIIIIII TYP. IIIII AROUND D 2x STUDS BEYOND, OPENING SEE PLAN FOR MORE _TI— — INFO 71— I I I IIII Uw) a= 1 IJL 1.11_A_=1L=_1L o =_IL U) FLOOR SYSTEM O7 CUT TO FIT 2x BOTTOM PLATE OPENING SIZE 1 BEYOND SEE PLAN SHEATHING DIAGRAM EXTERIOR SHEATHING SCHEDULE I N41 I: IN DOUBLE 2x4 TOP NAIL FIELD INSTALLED PLATE TOP PLATE TO FRAME WALL OR PRE - PROVIDE 2x4 ON TOP ASSEMBLED WALL OF 2x8 TO PAD OUT PANEL W/ (2) 10d NAIL,' TOP PLATE. ATTACH @ 8" O.C. (FOLLOW W/ (2) 10d NAILS 3" O.C. NAILING (SOLID BLOCK W/ 2x6) REQUIREMENTS THIS DETAIL FOR ALL TOP PLATE SPLICE LOCATIONS) 48„ TOP SPLICE DOUBLE 2x8 TOP PLATE TOP PLATE TRANSITION (2X4 TO 2X8 WALLS) PLATE . ,., PLATE TO EACH PLY OF BUILT UP COLUMN BELOW W/ (2) 10d NAILS TOP PLATE CORNER TRANSITION SHEATHING PER PLAN 1D 3/8" NAIL SHEATHING AT FRAME WALL BOTTOM PLATE z AND AT FLOOR TRUSS TOP & BOTTOM PLATES USING w _ U z (1) ROW OF 8d COMMON NAILS @ 3" O.C. 'A' = NAIL SPACING a = w O NAIL AT TOP PLATE USING (2) ROWS OF 8d COMMON 0 p Q LL N NAILS @ 3" O.C. A W O I— z O3 NAIL OPENING PERIMETER w/ (2) ROWS OF 8d 1/2_:Z4 1/2" E L (D COMMON NAILS @ 3" O.C. ! o — O = 4tJ NAIL INT. W/ 8d COMMON NAILS @ 12" O.C. & NAIL EDGES 6" O.C. U.N.O. ON PLANS A 1/2" - w STAGGER ALL VERT PANEL JOINTS & NAIL W/ 8d NOTES: 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES OF THE COLUMN 2) ALL NAILS PENETRATE AT LEAST 3/4" OF THE THICKNESS OF THE LAST LAMINATION 3) FOR 5-PLY, PROVIDE 1/4"DIA. x 5 1/2" LAG SCREWS OR EQUAL (SPACE AS SHOWN FOR 3-PLY) 4) TOLERANCES: ALL DIMENSION TO BE HELD WITHIN +/- 1/4" 1" EDGE 1 1/2" EDGE 10d x 3 COMMON p lo2 1/2" p Z- p W w 1 1/2" z _ Nlo lo W N 1 - N I 1 `" 10d x 3" COMM( 10d x 3" COMMON OPP. SIDE z CD U Ia. Q U) 00 0 (2) 2x4's (2) 2x6's �FOk TYPICAL BUILT-UP STUD COLUMN DETAIL c~n O COMMON NAILS @ 3" o.c. DOUBLE NAIL EDGE SPACING 2x SCAB w/ 10d NAILS 4' O.C. n U ® PLYWOOD SPLICES @ HEADER - NAIL SHEATHING TO EXTERIOR SHEATHING PER-ENG TRUSSES D O HEADER W/ 8d COMMON NAILS @ 3" O.C. (2) ROWS @ STUD PER PLAN L 0 _ r ILL p TOP & BOTTOM O (2) 8d NAILS @ 3" O.C. TO EACH TRUSS END OR @ VERTICAL MEMBER IF GABLE END SHEATHING SPLICE, BETWEEN EXTERIOR SHEATHING & TRUSS CONNECTION PER PLAN BLOCKING / GYPSUM WALLBOARD CMU WALL PER PLAN JOINT, MAX. 1/8 GAP NAILING PER SCHEDULE 2x4 BLOCKING PLACED FLATWISE (2) 16d NAILS EACH END SHEATHING SPLICE DETAIL NOTE: CONTRACTOR TO TAKE CARE AND NOT OVER DRIVE NAILS. IF NAILS ARE OVERDRIVEN, THE ENTIRE SHEET OF SHEATHING IS TO BE REMOVED AND REPLACED. IF MORE THAN 50% OF THE SHEATHING IS OVERDRIVEN, CONTACT FOR FOR REVIEW OF EXTERIOR STUDS SEE ROOF SHEATHING, PLAN NAIL PER PLAN (2) 2x BUILT-UP COL. — DOUBLE TOP PLATE SIMPSON SP4 OR SP2 2x BLOCKING W/ (2) @ EACH STUD 12d NAILS @ EACH END - PRE-ENGINEERED SIMPSON LSTA30 W/ — ROOF TRUSS - SEE (22) 10d NAILS (ALL z FRAMING PLAN FOR CORNER CONDITIONS SPACING EXTERIOR SHEATHING STRAP AROUND SEE PLAN FOR NAIL PER PLAN TALLER STUD) W CONNECTION 2x BRG WALL, SEE PLAN FOR STUD SIZE & SPACING. MIN (2) 2x UNDER GIRDER TRUSS U.N.O. 2x BLOCKING SIMPSON LSTA24 EACH STUD n2E j0 nm -42 L0 w 3/4"=1'-0" 2x BRG WALL, SEE PRE-ENG. ROOF PLAN FOR STUD SIZE & TRUSS PER PLAN SPACING. MIN (2) 2x UNDER GIRDER TRUSS SEE PLAN FOR U.N.O. CONNECTION WF_1'SECTION @ DOUBLE BEARING 3/4"=1'-0" CONTRACTOR MAY ELECT TO BUCKET SHORT SPAN BEAM INTO LONG SPAN AS INDICATED ON BEAM SCHEDULE. IF BUCKET IS INSTALLED THE SHORT SPAN STRAP IS NOT REQUIRED. EXT. BEAM PER PLAN PT POST PER PLAN LAP BEAM PLYS AND NAIL AS SHOWN (5) 10d NAILS PER PLY EXT. BEAM PER PLAN HTS20 CLIP FROM POST TO BEAM PLAN VIEW @ TOP OF POST PT POST PER PLAN ABU POST BASE PER PLAN 5/8" THREADED ROD w/ a' NUT SET IN ADHESIVE \ :r , SEE FOUNDATION PLAN FOR ADDITIONAL U INFO SIDE VIEW @ BASE OF POST (/ �lfli\ C`nPNIF=P MI I InnN FRAKAIN]r (2) 2x TOP PLATE ATTACH 2x TO BUILT-UP W/ (2) ROWS OF 10d NAILS STAGGERED @ 8" O.C. (2) 2x TOP PLATE oFN'_1�e r0 1-1 /2"=1 '-0" ROOF SHEATHING, FASTEN PER PLAN 2x4 FRAMING @ 24" O.C. MAX. PROVIDE (4)10d x3" NAILS AT JOINT 10d x 3" COMM( OPP. SIDE (2) 2x COLUMN 2x SCAB w/ 10d NAILS @ 4" O.C. PER-ENG TRUSSES - 2x FASCIA PER PLAN (2) 8d TOE NAILS TO LEDGER TRUSS CONNECTION PER PLAN 2x4 PT LEDGER W/ 1/4' x4 TAPCONS @ 12" 2x FRAME WALL PER O.C. PLAN RFF FI F\/ FnR CONDITION @ CMU WALL TYPICAL SCAB OVERHANG 3/4"=1'-0" 2 1/2" EDGE (2) 2x8's , O��FR 0�e U Z a W Q F- F- Q OUTSIDE (2) 2x4's EDGE DISTANCE w 0 PER �� J'IL U) C� 10dx3" z w � - N Z z w c� 2„ _0 N J U F- Z U N O w U) 1— cn ° ry co n 11 ao a wp � N O C) X 0 N v/ w o U 10d x 3" OPP. SIDE Z cl W z a- 0o m 000, 0 DISTANCE PER DETAIL U_ � w W INSIDE PLY NAILS NAILED AT 8" O/C 17 = STAGGERED. OUTSIDE NAILS NAILED AT 8" O/C. OUTSIDE 2X's 0 (3+) 2x COLUMN z %%%J1111I1ijill �� ®®®o' o w °®® ° i�/ o® J Z ROOF SHEATHING, CT w ; U3 Q U ROOF SHEATHING, FASTEN PER PLAN •� as � ' ®: Q 0 Q FASTEN PER PLAN c~n v• Z d° ®° • "" O P� 2x4 FRAMING @ 24" --�� O.C. MAX. PROVIDE (4) 10d x 3" 16d COMMON NAILS ii 2x4 #2 SYP CONT. w/ (2) w NAILS AT JOINT " EA. STUD OR TRUSS 0 0 ` MEMBER, TYP. (MAX. U 24" O.C.). IF MASONRY, 0 1`r,�.I co USE (2) 1/4"' TAPCONS IM ii. �r /MIN 2" EMBED w @ m °M� Q 2x FASCIA 24" O.C. r (2) 8d TOE NAILS d z TO LEDGER TRUSS PER PLAN Q - o 2x4 LEDGER W/ (2) 16d + NAILS @ 16" O.C. O aa) fn � U SEE ELEV. FOR WOOD/MASONRY +" 4 O.H. SIZE WALL OR TRUSS, SEE CONDITION n FRAME WALL PLAN(TRussSHOWN) o' V IX 2x4 #2 SPF SEE TRUSS PLAN FOR SEE TRUSS PLAN FOR BLOCKING @ 24" O.C. MORE INFO & MORE INFO & w/ (2) 16d END NAILS CONNECTION CONNECTION EACH END ++ xX X 2x12 BOX HDR w/ 2x8's TOP & BOT., 2x8 TO 2x8 #2 SPF VERTICAL 2x12 w/ 10d X 3" NAILS @ 24" O.C. w/ EXT. 2x4 #2 SPF @ 6" O.C. 2x12 AT SHEATHING PER BLOCKING @ 24" O.C. WALL TO PRECAST NAILING SCHEDULE & w/ (2) 16d END NAILS LINTEL w/ (2)ROWS OF + ++ + + (4) 12d NAILS EACH EACH END 1/4" x 4" TAPCONS @ 2x4 #2 SYP P.T. @ EA. TRUSS MEMBER 16" O.C. MAX. TRUSS w/ (4) 12d NAILS 2x8 w/ (2) 10d NAILS @ x x STAGGERED INTO TRUSS & (3) 12d TOENAILS INTO OTHER EACH VERTICAL SEE WALL CLIP DETAIL a x x TRANSOM BETWEEN TRUSS TRANSOM BETWEEN FOR MORE INFO SEE FLOOR PLAN FOR I LINTELS LINTELS MORE BRG. WALL INFO LINTEL PER PLAN SLOPE AS REQ'D LINTEL PER PLAN SLOPE AS REQ'D LINTEL PER PL' STEP @ BEARING FRAME WALL EXTERIOR WALL/TRUSS 12 ISEE PLAN 3/4"=1'-0" 2x6 SYP #2 LEDGER. TO STUDS w/ (2) 1/4" X 4'/2" SIMPS. SIDS SCREWS @ 16 O.C. MAX.; TO GABLE END STUDS v (2) 1/4" X 3'/" SIMPS. SD SCREWS @ 16" O.C. MAX.; TO MASONRY w/ 2x6 PT SYP #2 LEDGER w/ (2) 1/4" x 2 3/4" TAPCONS A7 12" O.C. SIMPSON H3 CLIP SHEATHING PER PLAN 2x4 SYP #2 LEDGER. -7SIDS (4) 10d NAILS FOR TO STUDS OR BEAM w/ (2) 1/4" X 4"/" SIMPS. CONY. FRAMED SCREWS @ 16" MEMBERS ONLY O.C. MAX.; TO GABLE END STUDS w/ (2) 1/4" X 3'/2" SIMPS. 4'-0" MAX. SIDS SCREWS @ 16"' FASCIA PER O.C. MAX.; COMMUNITY SPECS TO MASONRY w/ 2x4 PT 2x4 SYP #2 OR SYP #2 LEDGER w/ 1'/4" PRE-ENGINEERED x 2 3/4" TAPCONS @12" ROOF TRUSSES @ 24" O.C. O.C. MAX. SIMPSON H3 CLIP DESIGNED FOR SHINGLE ONLY S� TYPICAL SHED ROOF DETAIL 2x6 #2 SYP P.T. CONT. 2x6 #2 SYP P.T. CONT. w/ (2) 1/4" x 3 1/2" w/ (2) 1/4" x 3 1/2" TAPCONS @ 12" O.C. TAPCONS @ 12" O.C. SPACED EVENLY SPACED EVENLY VERTICALLY VERTICALLY 2x6 2x8 w/ (2) 10d NAILS @ 2x8 w/ (2) 10d NAILS @ POCKET SGD 3" O.C. TO EA. 2x6 POCKET SGD EACH VERTICAL POCKET SGD ATTACHMENT BY VERTICAL ATTACHMENT BY ATTACHMENT BY BUILDER BUILDER BUILDER S01 HEADER @POCKET SLIDER w/ TRANSOM S02 HEADER @ POCKET SLIDER w/ TRANSOM S03 HEADER @ POCKET SLIDER NOT USED 1 /2"=1'-0" 1 /2"=1'-0" a DO2 LEDGER @ LOW ROOF Ili F- m 0 J Z (D U�o� 7 r: W J 01— E - U_ Z M ti p O W z U� rn P Q U Z UHO(Doo OJ C) 0�wz(o � J u o w J �Z�a QOOo-v-2 SEE TRUSS PLAN FOR 2x8 TO UNDER SIDE OF F- _17 z z I- � w w o p MORE INFO ++ + ROOF SHEATHING Q � 0 U CONNECTION 2 0 a � IF ++ w U W Q vi¢ F- W j�NJ U N 2x8 #2 SPF VERTICAL 0 ` 2x8 #2 SPF VERTICAL @ 24" O.C. w/ EXT. X UJ 2 @ 24" O.C. w/ EXT. LINTEL PER PLAN SHEATHING PER �ni'� SHEATHING PER a. NAILING SCHEDULE & 0 W V NAILING SCHEDULE & (4) 12d NAILS EACH (4) 12d NAILS EACH TRUSS MEMBER (TOP _ TRUSS MEMBER AND BOTTOM CHORDS 0 ALONG W/ WEBBING) O o.. 2x8 w/ (2) 10d NAILS @ 2x8 w/ (2) 10d NAILS @ 2 EACH VERTICAL POCKET SGD EACH VERTICAL O ATTACHMENT BY z BUILDER 0 SO4 HEADER @ POCKET SLIDER O Z Q o 1/2"=1'-0" Z 0 1/2"=1'-0" LU H 00 11 H Q N z W ~ � Z J � - Ipw� z: W 00 O 0 1 0 P 0 LU �" Z Q (� m W O I— Z _ W � W O W -.5 QW_ U F- U) STRUCTURAL ENG: RMG Q DRAFTING: F- Z w -STRUCT: JV -- -- 0 cn QC CHECK: .- CC - W JOB No. TM - 2170194 SCALE: _. - AS INDICATED ~ DATE: 04/12/2017 SD4 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. SHINGLE OR TILE PER ARCHITECTURAL ELEVATIONS. PRE-ENGINEERED — ROOF TRUSSES @ 24" O.C. TYPICAL TRUSS TO - FRAME CONNECTION. SEE STANDARD CONNECTOR NOTES BEARING SEE PLAN SEE ARCHITECTURAL -' PLAN FOR OVERHANG INFO WINDOW AS SCHEDULED TV EXTERIOR FINISH PER PLAN MID -SPAN BLOCKING U.N.O. _ INSULATION PER PLAN SEE DETAILS WS10, WS11 OR WS13 FOR ADDITIONAL INFORMATION THIS SHEET NOTE: ALL FLOOR TRUSSES TO BE P.T. IF NO MOISTURE BARRIER (FELT PAPER OR SIM) IS PROVIDED BEARING SEE PLAN LINTEL AS PER PLAN LINTEL AS PER PLAN ---__ �WD. HD. HT. _ `•,I SEE PLAN PRECAST CONC. OR w POWERS STEEL SILL TYP. @ ALL WINDOWS EXT FINISH PER PLAN VERT REINF. BEYOND MASONRY WALL PER PLAN FIN. FLR. _ 0'-0" 00 GRADE DBL. TOP PLATE HDR. PER PLAN 2x STUDS, SEE FRAMING PLAN FOR SPACING AND GRADE AND SEE ARCH PLAN TO VERIFY SIZE INT. FINISH PER PLAN — 2x BOTTOM PLATE w/ (2) 12d AT 12" O.C. — 3/4" FLOOR SHEATHING ATTACHED PER NAILING SCHEDULE — FLOOR TRUSSES SEE PLAN FOR DEPTH AND DIRECTIONi NOTE: ALL FLOOR PRE-ENGINEERED TRUSS STRAP - SEE PRE-ENGINEERED TRUSSES TO BE P.T. IF ROOF TRUSS - SEE FRAMING PLAN FOR ROOF TRUSS - SEE NO MOISTURE » FRAMING PLAN FOR CONNECTIONS FRAMING PLAN FOR BARRIER (FELT PAPER LOCATION & SPACING LOCATION & SPACING PRE-ENGINEERED OR SIM) IS PROVIDED STRUCTURAL COL PER ROOF TRUSSES AT 24" TRUSS STRAP - SEE STRUCTURAL COL PER PLAN FOR SIZE AND O.C. FRAMING PLAN FOR « « PLAN FOR SIZE AND REQ'D # OF STUDS REQ'D # OF STUDS Q F- P Q Z C) w Cl) w_.. -.. CONNECTIONS ; » SIMPSON MSTAM36 " : DOUBLE 2x TOP PLATE DOUBLE 2x TOP PLATE SOLID SHEATHING @ SOLID SHEATHING @ o TYPICAL TRUSS TO STRAP W/ (10) 10d TO 2x BOTTOM PLATE 2x BOTTOM PLATE HEADER ' HEADER N FRAME CONNECTION. STUDS & (8) 1/4" X 3/4" FLOOR SHEATHING 3/4" FLOOR SHEATHING SIMPSON SP4 w/ (6) 10d SIMPSON SP4 w/ (6) 10d z SEE STANDARD 2-1/4" TITEN SCREWS ATTACHED PER ATTACHED PER F�<� S x1-1/2" @ 24" O.C. (USE <<Sy x1-1/2" @ 24" O.C. (USE Z CONNECTOR NOTES TO LINTEL COURSE. NAILING SCHEDULE NAILING SCHEDULE SIMPSON LSTA30 hFFr SP6 @ 2x6 STUDS & SIMPSON LSTA30 FFT SP6 @ 2x6 STUDS & 0 0 USE SIMPSON :» STRAP (MAX 10° SP8 @ 2x8 STUDS) STRAP (MAX 10° SP8 @ 2x8 STUDS) w MSTCM60 STRAP W/ »» ANGLE) W/ (22) 10d ANGLE) W/ (22) 10d Lo REFER TO PLAN FOR (20) 16d SINKERS & (14NAILS. BEND STRAP NAILS. BEND STRAP BUILT-UP COLUMN 1/4" X 2-1/4" TAPCONS OVER TOP PLATE MIN. (2) 2x SPF TOP PLATE (2) 2x SPF TOP PLATE w INFO. U.N.O. ON PLAN OVER TOP PLATE MIN. U.N.O. ON PLAN O (� FOR TRUSSES 20" TO 3", THEN RUN DOWN 3", THEN RUN DOWN »» " HEADER -SEE 2ND (D W 26" DEEP " FACE OF JAMB STUDS/ HEADER -SEE 2ND FACE OF JAMB STUDS/ PRE-ENG. FLOOR FLOOR PLAN FOR MIN. Z SYSTEM - IF NO FLOOR (IF TITENS ARE NOT IN HEADER FLOOR PLAN FOR MIN. HEADER HEADER SIZE & REQ'D 0 I) SYSTEM INSTALL LINTEL COURSE OR EXTERIOR SHEATHING HEADER SIZE & REQ'D JAMB STUDS INTO FILLED CELL USE "» (1) SIMPSON LSTA30 JAMB STUDS 0 KNEEWALL &PROVIDE 1/4" X 1 3/4" TITENS) "" STRAP W/ (11) 10d TO FROM TOP OF WALL EXTERIOR SHEATHING In SOLID BLOCKING ;; FLOOR TRUSS SEE TO BOT. RIBBON, NAIL FROM TOP OF WALL `C U.N.O. »« FLOOR TRUSS PER STUDS ABOVE PLATE UNDER COLUMN FRAMING PLAN FOR PER PLAN PLAN U.N.O. IF HEADER IS UPSET TO BOT. RIBBON, NAIL of ABOVE .. CONNECTION INFO PROVIDE SOLID (2) 2x SILL AT WINDOW AND WINDOW IS PER. PLAN O - SEE DETAIL WS11 FOR w/ 2x CRIPPLE STUDS LOWER: (1) 2x SILL IF HEADER IS UPSET LL BAND JOIST & BLKG BLOCKING BELOW FLOOR GIRDER OR AND WINDOW IS w LU OR LVL GIRDER COL. EVEN WITHIN MORE INFO AT EA. END NAILED TO PLATE w/ (2) 10d BEAM; SEE PLAN LOWER: (1) 2x SILL = W FLOOR TRUSS MASONRY WALL SEE STUD PACK w/ 10d TOENAILS. EXT. H � NOTE: ALL FLOOR PLAN FOR MORE INFO NAILS @ 8" O.C. THEN HEADER OPENINGS PLATE w/ (2) 10d w TRUSSES TO BE P.T. IF STUDS @ 16" O.C. LESS THAN 4FT:(1) 2x TOENAILS. EXT. O NO MOISTURE SO TYPICAL GIRDER COL. CONNECTION SO TYPICAL GIRDER COL. @ HIGH BEAM ATTACH SILL w/ (2) 1od SILL PLATE w/ (2) 1od HEADER OPENINGS z BARRIER (FELT PAPER OR SIM) IS PROVIDED 3/4"=1'-0" 3/4"=1'-0" TOE NAILS AT EA. END TOENAILS. OPENING LESS THAN 4FT:(1) 2x p uj C OF SILL (MAX OPEN'G LARGER THAN 4FT: (2) SILL PLATE w/ (2) 1Dd cn ®�®i�r�����av�®0®®� p d. WIDTH 4'-0"). USE A35 2x SILL PLATE w/ A35 TOENAILS. OPENING ®® '� ®i® oo (2) 2x SILL AT WINDOW.®®®000®�®-0, w REFER TO PLAN FOR 2x 2ND FLOOR STUDS CLIP AT EA. END FOR CLIPS EACH SIDE w/ 2x LARGER THAN 4FT: (2) ®® •®• /lj � 1 0 w/ 2x CRIPPLE STUDS o / ® � BUILT-UP COLUMN 2x SILL PLATE w/ A35 • ® l� Z SEE PLAN FOR MORE (2) SIMPSON LSTA18 OPENINGS GREATER CRIPPLES @ 16" O.C. AT EA. END NAILED TO a ® 1 w ®•m INFO. STRAPS CENTERED @ THAN 4' BUT LESS w/ (2) 10d TOENAILS STUD PACK w/ 10d CLIPS EACH SIDE w/ 2x �� ®,d- Olt BEARING WALL PER FLOOR W/ 14) 10d THAN 6' T&B PLYWOOD CRIPPLES @ 16" O.C. PLAN BEYOND A A NAILS (A ( NAILS @ 8 O.C. THEN O ® Z ®®� SEE FLOOR FRAMING SIMPS. MSTAM36 w/ SHEATHING REQ D STUDS 16' O.C. w/ 2 10d TOENAILS • ® Q COLUMNS PLAN FOR FLOOR (7) 10d NAILS & (4) 1/4" T&B) ATTACH SILL w/ (2) 10d T&B (PLYWOOD •®® v: - MID -HEIGHT BLOCKING x 2 1/4" TITENS; IF » TOE NAILS AT EA. END SHEATHING REQ'D oo®� ®boo ®k O SYSTEM INFO. »" SEPARATE SHEATHING T&B �••®• PER BEARING WALL "; OF SILL MAX OPEN'G ) I— ® ®® `� U- FLOOR TRUSSES ARE UNDER WINDOW SCHEDULE ATTACH 2x STUDS W/ (3) 2x STUDS 20"- 26" DEEP, USE "" WIDTH 4'-0"). USE A35 ®®�/Si/111 P 1/2" DIA. THREADED (2) SIMPSON LSTA18 (2) 16d NAILS @ 6" O.C. SIMPS. MSTCM60 " CLIP AT EA. END FOR ROD WITHIN 6" FROM STRAPS CENTERED @ STRAP w/(20) 16d " OPENINGS GREATER w COL; SEE BRG WALL/ FLOOR w/ (14) 10d SINKERS & (14) 1/4" X 2 THAN 4' BUT LESS a f . CALIFORNIA CORNER A -A 1/4" TITENS INSTEAD. 2-ST6RY WALL NAILS (2) SIMPSON LSTA18 »� THAN 6', O. SECTION FOR MORE STRAPS CENTERED (IF TITENS ARE NOT IN U (2) SIMPSON META16 @ LINTEL COURSE OR \ 2 OP & BOT: \ FLOOR W/ 14 10d INTO FILLED CELL USE X. SIMPSON Od TO STUDS / FLOOR TRUSS TO _ Z INFO. ( ) � » NAILS »» RIBBONS, CONT. ( )ti REFER TO MASONRY WALL 1/4" X 1 3/4 TITENS) RR ABOVE PLATE U.N.O. , co Co FOUNDATION PLAN FOR FTG. (3) 2x STUD PACK NOTE: ALL FLOOR EXT. SHEATHING ATTACH PER NAILING TRUSSES TO BE P.T. IF�' z`J INFORMATION FLUSH W/ FACE OF SCHEDULE NO MOISTURE MASONRY ATTACHED SEE FRAMING PLAN Q 0 0 ATTACH 2x STUDS W/ - BARRIER (FELT PAPER FOR FLOOR PER NAILING _ (2) 16d NAILS @ 6'" O.C. 4 2x STUDS OR SIM) IS PROVIDED CONNECTION � � ni SCHEDULE; PROVIDE O SEE FRAMING PLAN rw 1/8" GAP BETWEEN IF FLOOR SYS. NOT PRESENT PER FLOOR FOR FLOOR O ''�@',,I,i, �'� W SHEATHING AND STANDARD CORNER A -A 0 '' U FRAMING PLAN, 2nd FLR STUDS TO BEAR ON CONNECTION Z MASONRY NOTE: IF WOOD WALL OR BEAM BELOW USE CMU WALL BELOW PER DETAIL INCDICATED SIMPSON MSTC40 W/ (36) 16d SINKERS. IF FLOOR ON FLOOR FRAMING. INDICATED BASE STRAP BELLOW JAMBS VIDE KING FLOOR GRIDER ORO S+ MASONRY WALL PER REQ D ON EITHER SIDE OF WALL IF WF02/ FLOOR SYSTEM DRAFT SYSTEM IS 18" TO 36" DEEP USE MSTC66 W/ 60 16d PLAN _ . _ _ _ SD6 IS INDICATED BASE STRAPS ARE REQ'D MASONRY WALL SEE � ( " STOPPING AT 1000 SQ SINKERS AND 14) Y4"X2 " FT MAX: DRAFT STOPPING MATERIALS MIN THICKNESS SHALLfiso_, TYPICAL TWO STORY COL. @ GIRDER A—s-o'k2nd FLOOR CORNER FRAMING ATTACHMENT MASONRY ON BOTH SIDES OF THE WALL PLAN FOR MORE INFO CL U fi SO HEADER CONNECTION @ 2nd FLOOR ASAHEADER CONNECTION @ 2nd FLOOR HIGH BM H BE 1/2" GYP BOARD OR 3/4"=1'-0" 3/4"=1'-0" 3/4"=V-0" 3/4"=1'-0" 15/32" OR 7/16" OSB. a ATTACH TO FLOOR TRUSS 8d NAILS AT 3/4" FLOOR SHEATHING SHEATHING PER 3/4" FLOOR SHEATHING SHEATHING PER 3/4" FLOOR SHEATHING SHEATHING PER f 0 w/ 16" O.C. TOP AND ATTACHED PER DETAIL WF10/SD4 ATTACHED PER DETAIL WF10/SD4 ATTACHED PER DETAIL WF10/SD4 p Z C� BOTTOM CHORDS NAILING SCHEDULE NAILING SCHEDULE NAILING SCHEDULE SHEATHING PER -PLAN ATTACH PER NAILING Q J r- U) U o 2x STUDS ,SEE 2x STUDS, SEE UNDER WINDOWS AND 2x STUDS , SEE SCHEDULE, U_ 0 �, W _j 0)FRAMING 2x4 #2 SYP BLOCKING FRAMING PLAN FOR FRAMING PLAN FOR GIRDERS: BLOCK PLAN FOR CONTINUOUS FROM Z < p p w �, E U) Z � r 0 @ 48" O.C. W/ (2) 12d SPACING AND GRADE SPACING AND GRADE SOLID BETWEEN SPACING AND GRADE TOP OF TOP PLATE TO O 06 H Z W _j rn R TOENAILS EACH END AND SEE ARCH PLAN SYS. 42 FLOOR AND SEE ARCH PLAN RIBBONS w/ SIMPSON AND SEE ARCH PLAN GIRDER TRUSS PER BOTTOM PLATE. ~ W (D Q O W ( - ANGLE TO VERIFY SIZE TRUSSES @ 24" O.C. TO VERIFY SIZE A35 EA. END 2x BLOCKING FOR — TO VERIFY SIZE PLAN U Z C� a U U Z w 2x4 #2 SYP 2x BOTTOM PLATE W/ (MAX) 2x BOTTOM PLATE W/ 2x BOTTOM PLATE W/ BEARING WALL PER O Q I- U) _ H - c ST TRUSS (2) 12d @ 12 O.C. (2) 12d @ 12' O.C. RYWAL 2 12d @ 12" O.C. O PLAN w � Qppo-v VERAGATICAL @ 8" O.C. ATTACHMENTDw/ (2) 12d _ Cl) o Z 2 W/ (3) 12d NAILS EACH PRE-ENG FLOOR 2x SYP #2 RIBBON (MIN TOENAILS EA. END 2x SYP #2 RIBBON (MIN DOUBLE BOTTOM PLATE I - 2 N Z I- I—w uJ 0 z Q U ~ z E END TRUSS OR FIELD 2x4) TO TRUSS w/ (4) 2x4) TO TRUSS w/ (4) I- _ LL �Qwz0 U FRAME 2x4 KNEE 16d NAILS; BOTTOM 16d NAILS; BOTTOM (2) H5 EA. FLOOR O p a WALL, STUDS @ 16" RIBBON TO BE PT IF RIBBON TO BE PT IF TRUSS TO DOUBLE w U Q ~ �- - SYS. 42 FLOOR O.C. W/ (2) 16d NAILS @ BRG DIRECTLY ON BRG DIRECTLY ON BOTTOM PLATE, SLIT z W N -� Z O U N �C CONC. SLAB - TRUSSES @ 24" O.C. EACH END SEE CMU CMU SEE TRUSS LAYOUT FLOOR DECKING TO -I O SEE FOUNDATION (MAX) CONNECTOR (2) ROWS 8d NAILS @ FOR HANGER ACCOMMODATE 0 PLAN FOR MORE INFO L 1/2" GYP. CLG BD OR SCHEDULE FOR 1/2" GYP. CLG BID OR (2) ROWS 8d NAILS @ 3" O.C. TYP. WALL STRAP CV (2) 5/8" TYPE "X" WHEN CONNECTION (2) 5/8" TYPE "X" WHEN 3" O.C. WALL SHEATHING TO EA. Q W IN GARAGE (1) ROWS 8d NAILS @ IN GARAGE SHEATHING TO SEE PLAN FOR RIBBON 2x RIBBON OR ? _ MASONRY WALL PER 3" O.C. WALL MASONRY WALL PER - BOTTOM RIBBON SIMPSON META16 AT - CANTILEVER BLOCKING w/ (4) 16d C] EATHING TO MASONRY OR MTS112 11J PLAN SH PLAN OR (3) 16d TOENAILS BOTTOM PLATE 1/8 GAP BETWEEN AT WOOD NOTE: ALL FLOOR SEE FOUNDATION NOTE: ALL FLOOR NOTE: ALL FLOOR. SHEATHING &CMU DETAILS FOR FTG INFO TRUSSES TO BE P.T. IF 1/8" GAP BETWEEN TRUSSES TO BE P.T. IF TRUSSES TO BE P.T. IF NO MOISTURE SHEATHING & CMU NO MOISTURE MASONRY OR FRAME NO MOISTURE BARRIER FELT PAPER SEE CONNECTION WALL PER PLAN BARRIER (FELT PAPER BARRIER (FELT PAPER 2x4 PT SILL PLT. IF ( OR SIM) IS PROVIDED KNEEWALL OR SIM) IS PROVIDED TRUSS PER PLAN SCHEDULE OR SIM) IS PROVIDED TYPICAL TWO STORY SECTION fisf(TWO STORY PARALLEL FLOOR CONNECTION S1 TWO STORY PERP. FLOOR CONNECTION fiSl CANTILEVERED FLOOR TRUSS CONNECTION fiS1 FLOOR TRUSS TO GIRDER CONNECTION 3/4"=1'-0" 3/4"=V-0" 3/4"=1'-0" 2nd FLOOR WALL; SEE PLAN FOR MORE INFO. IF SHEATHING IS NOT CONTINUOUS TO BOTTOM OF FLOOR TRUSS, CONTRACTOR TO INSTALL SIMPSON LSTA18 STRAPS FROM EA, STUD TO TRUSS 2x12 #2 SYP CONT. LEDGER W/ (3) 1/4"x4-1/2" SIDS SCREWS (EQUALLY SPACED VERTICALLY) SEE PLAN @ 24" O.C. AND @ EA. — END VERTICAL (MIN. 2" FROM T&B) SEE PLAN FOR FLOOR TRUSS DIRECTION SEE WS10/SD5 OR WS11/SD5 FOR ADDITIONAL INFO F01 TYPICAL BALCONY FRAMING 3/4"= V-0" 3/4"=1'-0" NOTE: ALL FLOOR TRUSSES TO BE P.T. IF NO MOISTURE HANDRAIL BY OTHERS BARRIER (FELT PAPER OR SIM) IS PROVIDED Z J n SEE ARCH DWGS FOR w TOPPING INFO 3/4" PLYWOOD FLOOR DECKING ATTACHED SLOB PER NAILING CONTRACTOR TO "4 PROVIDE ADEQUATE WATERPROOFING. NO °�. CONCRETE SLAB PERMITTED SCHEDULE SLOPED BALCONY FLOOR TRUSS (12" TALL) (60/15/5 MIN. LOADING) W/ LUS26 OR LUS46 TO LEDGER SEE WS11/SD5 FOR SIM. END CONDITION LINTEL PER PLAN NOT USED C Q 0 Z 0 J _ 00 00 C Z J 0 0 W J �00W 0 fir, m <M= j � H 0. F-- 0 CL STRUCTURAL ENG: RMG C DRAFTING: -STRUCT: JV QC CHECK: CC JOB No. TM - 2170194 SCALE: AS INDICATED DATE: 04/12/2017 SD5 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. 2x BRG WALL W/ SIMPSON SP2 @ TOP & SP1 @ BASE. LSTA18 (2) 2x BASE PLATE w/ OR MTS12 MAY BE (2) 12d NAILS @ 12" USED @ BASE O.C. USE SIMPSON EXTERIOR SHEATHING MTS12 OR LSTA18 TO ATTACH PER NAILING BLOCKING BELOW. SCHEDULE 2x BLOCKING W/ (2) 12d NOT REQ'D IF STUD IS TOENAILS EACH END CONNECTED w/ MTS12 2x BASE PLATE W/ (2) OR LSTA18 12d NAILS @ 12" O.C. 2x BLOCKING W/ (2) 12d 3/4" FLOOR SHEATHING TOENAILS EACH END ATTACHED PER NAILING SCHEDULE (2) 2x4 #2 SYP (2) 2x4 #2 SYP BLOCKING w/ SIMPSON BLOCKING w/ SIMPSON HUC24-2 EACH END, HUC24-2 EACH END, USE (4) 10d & (2) 10d USE (4) 10d & (2) 10d NAILS. UNDER NAILS. UNDER SEE PLAN WINDOW JAMBS ONLY WINDOW JAMBS USEEl (2) 2x6 w/ HUC26-2. LOW ROOF TRUSS SEE LOW ROOF TRUSS SEE FLOOR TRUSS PER TRUSS PLAN FOR TRUSS PLAN FOR 17 PLAN CONNECTIONS (IF CONNECTIONS TRUSS IS CONT. BRG MASONRY (SHOWN) ON MASONRY USE OR WOOD WALL PER META16 @ 24" O.C. OR PLAN ON WOOD USE HGA CLIPS @ 24" O.C.) SECTION @ RAISED HEEL TRUSS fi S1 SECTION @COMBO TRUSS (2) 2x SYP #2 COLUN ON EITHER SIDE OF GIRDER, PROVIDE SUFFICIENT ROOM FOR GIRDER HANGE FLANGE. ATTACH LEDGER TO EA. COLUMN w/ (4) 1/4" 3-1/2" (8 TOTAL) SIMPSON SDS SCREWS LEDGER AT GIRDER NOT USED 1 /2"=1'-0" OTHERS PLAN ISIMPSON H2.5 EA. TRUSS R PLAN 1-1 /2"=1'-0" 'RECESS LEDGER 15 (TRUSS. VERIFY W/ TRUSS SHOP 'DRAWINGS 2x8 SYP #2 LEDGER MIN. (4) 16d NAILS T EACH STUD (AT EACH SIDE OF G.T. USE (4) OPT. TRUSS RECESS LEDGER 16d NAILS) 2x BRG WALL W/ SIMPSON SP2 @ TOP & 2x8's MIN. SPF #2 SP1 @BASE. LSTA18 O.C. MAX (U.N.O.) OR MTS12 MAY BE USED @ BASE.(WHEN MSTAM24 EA. SIDE WALL IS CONT. BRG ON EA. STUD TO WALI TRUSS STRAP STUDS BELOW W/ (9) 10d w/ LSTA18 @ 16" O.C. NAILS AND (5) 1/4" TO TRUSS BELOW) 3/4" TAPCONS PEF 3/4" FLOOR SHEATHING STRAP; CENTER ATTACHED PER STRAP BETWEEN NAILING SCHEDULE MASONRY WALL P FRAME WALL FLOOR TRUSS PER PLAN 2x8 #2 SYP P.T. SI. PLATE w/ 1/2" EPIC ANCHOR BOLT 01 J-BOLT W/ MIN. 7" EMBED. @ 32" O.0 SEE FROM EA.END SEE ARCHS FOR FURRING AND INTERIOR FINISH MASONRY (SHOWN) MASONRY WALL F OR WOOD WALL PER I PLAN PLAN 1 /2"=1'-0" WALL SPLICE DETAILS EXTERIOR SHEATHI"" FROM TOP OF WALI TO BOTTOM OF SILL PLATE ATTACH PER NAILING SCHEDULE ROOF SHEATHING ATTACH PER NAILIf SCHEDULE PRE-ENGINEERED TRUSS PER PLAN LEDGER (d)- OPEN TO BELOW <6 #2 SYP CONT. =DGER W/ (2) Y4"x3-1/2" DS WOOD SCREWS @ _ i" O.C. MAX. & 3" EOM EA. END - USE SCREWS FOR 24" I SIMPSON LUS26. U: C. LUS26-2 FOR 2PLY TRUSS 3/4"=1'-0" EXTERIOR SHEATHING FROM TOP OF WALL TO BOTTOM OF SILL PLATE ATTACH PER _ NAILING SCHEDULE ROOF SHEATHING — ATTACH PER NAILING ISIMPSON H2.5 EA. TRUSS I SCHEDULE PRE-ENGINEERED — no TRUSS PER PLAN ' 2x6 #2 SYP CONT. LEDGER W/ (2) Y4"x3-1/2" I SIMPSON LUS26.. USE RECESS LEDGER INTO SDS WOOD SCREWS @ LUS26-2 FOR 2PLY VERIFY W/ 16" O.C. MAX. & 3" TRUSS (TRUSS. TRUSS SHOP FROM EA. END - USE (3) 'DRAWINGS— I_ SCREWS FOR 24" O.C. 2x8 SYP #2 LEDGER W/ MIN. (4) 16d NAILS TO EA. TRUSS, 24" O.C. OPT. TRUSS RECESS LEDGER G TXUSE (4) 16d NAIILS) LEDGER @ LOW ROOF 3/4"=1'-0" EXT. FINISH PER 2x8 MIN. SPF #2 @ 16" ARCHS O.C. - SEE FRAMING PLAN FOR MORE INFO. 2x4 BLOCKING BETWEEN STUDS W/ SHEATHING PER (2) 12d TOE NAILS DETAIL WF10/D4 EACH END ATTACH SHEATHING 1 2x4 BLOCKING TO BOTTOM PLATE BETWEEN STUDS W/ W/ (1) ROW 8d NAILS (2) 12d TOE NAILS @ 3" O.C. EACH END REQUIRED AT ALL SHEATHING SHEATHING TO PANEL EDGES OVERLAP BOTTOM PERPENDICULAR TO PLATE 1 1/4" (MIN.) VERTICAL WALL 1x PT NAILER AS REQ'D FRAMING MEMBERS CONT. #5 IN TIE BEAM EXT. FINISH PER ARCHS r SECTION @ OPEN TO ABOVE 1-1 /2"= V-0" 2x8 #2 SPF MIN STUDS @ 16" O.C. PER PLAN 12 PER PLAN 2x4 CONT. W/ (2) 12d NAILS TO EACH STUD I 2x8 #2 SYP P.T. SILL PLATE W/ Y2" EPDXY ANCHOR OR J-BOLT @ 32" O.C. W/ MIN. 7" EMBEDMENT & 6" FROM EACH END (2) 2x TOP PLATE — (2) 2x HEADER SEE — MASONRY WALL PER PLAN FOR MORE INFO PLAN & CONNECTIONS WINDOW SEE PLAN FOR LOCATION 2x BLOCKING w/ (2) 12d TOENAILS EACH SIDE IF WALL SHEATHING IS STOPPED BELOW ROOF LINE 2x BASE PLATE W/ 12d @ 24" O.C. TO FLOOR 2x4 CONT. W/ (2) 12d SYSTEM BELOW NAILS TO EACH STUD 2nd STORY WALL PER PLYWOOD FLOORING PLAN SEE FLOOR FRAMING PLAN FOR MORE INFO SEE PLAN FOR TRUSS DIRECTION & MORE INFO FLOOR TRUSS; SEE FRAMING PLAN FOR DIRECTION AND - CONNECTION DETAIL MASONRY WALL PER PLAN FLOOR GIRDER SEE PLAN FOR CONNECTION O.H. PER ELEV. EXT. SHEATHING 2x4 NAILER W/ (2) — ATTACH PER NAILING 10d NAILS @ 16" O.C. SCHEDULE 2x4 STUDS @ 16" O.C. 1/2" GYP. BOARD SIMPSON H10A @ SEE LD02/SD4 FOR EACH DIAGONAL MORE INFO. BRACE ALL THREAD ROD @ 48" O.C.; SEE FOUNDATION DETAILS FOR CONNECTION @ BASE 2x4 BOTTOM PLATE, IF SHEATHING IS NOT CONNECT TO DOUBLE CONTINUOUS TO BASE TOP PLATE W/ 16d PLATE, SP8 TOP AND NAILS @ 6" O.C. BOTTOM ARE REQ'D C.M.U. WALL PER PLAN (2) 2x4 TOP PLATE 2x BEARING WALL WITH ROOF LOAD F1 BRACING @ 2 STORY FRAME WALL PRE ENGINEERED TRUSSES @ 24" O.C. MAX. PER PLAN SEE ARCHS FOR ROOF WATERPROOFING AND FINISH TRUSS ANCHOR (SEE PLAN) ROOF SHEATHING ATTACHED PER NAILING SCHEDULE 2x #2 SPF STUDS @ 16" O.C. w/ EXT. SHEATHING FROM TOP OF WALL TO BOTTOM OF TRUSS/ GIRDER SEE PLAN FOR WINDOW ATTACHMENT INFO. IF WALL SHEATHING ISN'T CONT. LSTA18 STRAPS ARE REQ'D FROM STUDS TO GIRDER BELOW SEE LD02/SD4 FOR MORE INFO IF TRUSSES ARE PARALLEL TO WALL ROOF SHEATHING ATTACHED PER NAILING SCHEDULE SEE TRUSS LAYOUT FOR TRUSS LOCATION & CONNECTION INFO TYPICAL CONNECTION @ GIRDER OR BEAM 3/4"=1'-0" SHEATHING CONT. TO 2x4 BLOCKS, (2) 16d W 2nd STORY WALL NAILS @ EACH END. Q BOTTOM PLATE BLOCK ADJACENT z Q .ATTACH PER NAILING BAYS @ EACH W SCHEDULE DIAGONAL AS SHOWN. FASTEN ROOF W - SHEATHING TO BLOCKS W/ 8d NAILS @ i 6" O.C. o N_ z O (5) 16d NAILS BRACE N Z TO BLOCKING ❑W 0 `'--- PROVIDE 2x4 BRACE W i 0- TO EACH ADJACENT W DIAGONAL, FASTEN ❑ 0 TO DIAGONAL W/ (2) U) 16d NAILS Z W Z r) TRUSSES PER PLAN m O.S.B. TO OVERLAP Q BOTTOM PLATE 1 1/4" WALL BRACING @ 48" ❑ (MIN.) O.C. MAX. 45° FROM 0 O 2x LEDGER TO UPPER HORIZONTAL (+/- 10") L FLOOR WALL W/ BRACE NOT REQUIRED W W 1/4" X 3-1/2" SIMPSON 6' FROM EAVES. H W SDS SCREW @ 16" O.C. W O z ���►dil�rr�®r®® O S. ��®®® LLl M • ' • LLJ ® �, O p r � _ • U (2) 2x SPF TOP �� .0 ©• 0 J PLATES U.N.O. (2) 2x HEADER SEE FLOOR PLAN 1 FOR MORE INFO 1 1 1 1 1 1 1 1 I I 2x STUDS SEE PLANSTUDS E ARE TO ALIGN W/STUDS ; BELOW 1 1 1 I 1 1 1 I 1 1 B 1 1 1 1 1 1 1 1 1 1 1 I I 2x SPF BASE I PLATE PRE-ENGINEERED FLOOR SYSTEM KNEEWALL OR BEAM (2) 2x SPF TOP PLATES U.N.O. 1 1 1 1 (2) 2x HEADER 1 1 2x STUDS SEE PLAN STUDS ABOVE ARE TO ALIGN W/ STUDS BELOW 1 I I I SEE FLOOR PLAN FOR MORE INFO B 1 1 1 1 1 1 1 1 ' 2x P.T. BASE PLATE SEE BEARING SCHED. FOR A.B. INFO I 1 •. v� ® W Q h 4A111111� LL W O° O� U Z Q clS o H a. z O U 0 W O �I �. Z O. s. O .., ' J (D Cc) � ti U_ O _ Q W J0'7� 0- O W M E O �— o�j Z (n u- 0 U Z p o 0 0 Q W zlo — C W 0 dOp�� 0 f- ZI-�W W p O WQWZo U 2 LOL LU 0 Q SOW U CV J 1 SEE FOUND. PLAN FOR FTG. REQ. I I I zz J f— Z p U N Q U O O 1/2" THREADED ROD SEE BEARING SCHEDULE ON FLOOR PLANS FOR O AT OPENING LARGER THAN 4'-2" ATTACH TOP PLATE TO HEADER WITH LSTA12 BENT OVER O U I— N MORE INFO MAX 6" FROM KING STUD W/ (5) 10d NAILS INTO TOP PLATE AND (5) 10d Q J NAILS INTO HEADER IF PORTIONS OF THIS WALL Z p W = OSEE CHART FOR REQUIRED JACKS / KINGS # OF STUDS TO MATCH IF 2ND FLOOR HEADER SITS OVER 1ST FLOOR HEADER CONTACT FOR TO ARE EXTERIOR, PROVIDE EXT. SHEATHING ATTACHED PER W p BETWEEN FLOORS REVIEW THREADED ROD SPACING NAILING SCHED., CONT. TO 0- �`— BOTTOM OF FLOOR SYSTEM C� FLOOR TRUSS DOES NOT ALIGN DIRECTLY z OIF UNDER 2ND STORY COLUMNS, PROVIDE Q SOLID BLOCKING WITHIN FLOOR SYSTEM O 2 STORY INTERIOR BEARING WALL UNDER 2ND STORY COLUMN LOCATION. o Z o 1 ""=1'-01, z 'S 0 _ ~ 00 00 ❑ i> N z W h- zJ0 cn 0WJ I- C0 o� W O 10W (D 0 o Z 0 z p: m W I— 0�Z ❑ W 0 (n STRUCTURAL ENG: RMG Q DRAFTING: H z W .. -STRUCT: JV -. 0 QC CHECK: CC JOB No. TM - 2170194 SCALE: AS INDICATED ~ DATE: 04/12/2017 SD6 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, Or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. — STANDARD (3) 2X12 MIN. (3) 2x SYP #2 STRINGERS W/ STUDS REQ'D @ END SIMPSON A34 CLIP TO Q W OF LANDING W/ MIN. (6) FLOOR SYSTEM Q 16d NAILS FROM IZ C) LEDGER TO STUD PACK v) w--- - - - - - - - - ------ LINE UP 2xJOIST IN LINE WITH MIDDLE o STANDARD O 3 2X12 /,/ 2x12 STRINGER TO BE STRINGERS W/ UTILIZED AS BLOCKING Z SIMPSON A35 / A34 O CLIP TO FLOOR % Z SYSTEM &LANDING w 0 FRAMING 2xJOISTS @LANDING c � z @ 16"O.C. W/ SIMPSON a. A35 OR LUS26 HANGER LU gON EACH SIDE O 0o O W 6" MIN. Z 0 10 (2) 2x BEAM PER 2xJOIST (P.T. IF SCHEDULE REQ'D @ 4'-0" MAX ATTACHING TO LU L J END OF LANDING FOR WIDTH OF LAND NG MASONRY WALL) CONT = o H ry STRINGERS TO MID SPAN BLOCKING LEDGER w/ (3) 16d z O CONNECT TO. BEAM TO MATCH JOIST NAILS @ 16" O.C. MAX. TO BEAR DIRECTLY ON DEPTH W/ (3) 10d TO EACH STUD. ((2) 1/4" z BUILT UP COLUMNS TOENAILS EACH END x 3 1/2" TITENS @ 16" O LLj o) BELOW O.C. MAX. FOR iD MASONRY WALL) `� 10"' MIN. > b% �I®®� Uj ono A -A PLAN VIEW @ 90 DEGREE TURN LANDING ®r$00*00®® ®.�ti��. L SEE SCHEDULE FOR MAX WIDTH OF LANDING• `2 c U. Q p®\add `� U MIN. (3) 2x SYP #2 'fl W 00, ; = -j STUDS REQ'D @ END .+; p 4 • z � rt z Q .! • OF LANDING W/ MIN. (6) 3/4" PLYWOOD OR OSB . "� � Q O 16d NAILS FROM SEE OF LANDING PLAN FOR DEPTH s � a.,®®� ®®e , ��` SHEATHING OVER * �• p LEDGER TO STUD LANDING ATTACHED STAIR WINDER DETAIL ®� m LL PACK PER GENERAL FLOOR CONSTRUCTION U) J � 11111 \\ NOTES • _` MID SPAN BLOCKING TO MATCH JOIST PLYWOOD SHEATHING O DEPTH W/ (3) 10d 2xJOIST LEDGER (P.T. OVER LANDING U STANDARD (3) 2X12 TOENAILS EACH END IF ATTACHING TO ATTACHED PER MASONRY WALL C SYP #2 STRINGERS W/ SIMPSON A34 / A35 M Q _ O ) GENERAL FLOOR Q / � CONSTRUCTION � ., CLIP TO FLOOR ? NOTES 16" O.C. fY w 0 w o SYSTEM & LANDING Z FRAMING O0 ¢ MAX �� 1 - BEAM @END OF <C o / p LANDING PER SCHEDULE o O w ' w Cj) U h, ' U) Z' SEE PLAN FOR p M MASONRY WALL OR cn O'er WOOD WALL �` ;SIMPSON A35 � Q' B B CONNECTIONS d / MASONRY WALL OR FRAME WALL BEYOND U r (2) 2x BEAM PER 2x JOIST (P.T. IF H SCHEDULE REQ'D @ 2x JOISTS PER ATTACHING TO END OF LANDING FOR SCHEDULE @ LANDING MASONRY WALL) CONT R R p p O Z STRINGERS TO @ 16"O.C. W/SIMPSON LEDGERw/(3) 16d u-u CROSS SECTION OF BEAM TO LEDGER CONNECT TO. BEAM A35 OR LUS26 HANGER NAILS 16" O.C. MAX. LL Uj TO BEAR DIRECTLY ON ON EACH SIDE TO EACH STUD. ((2) 1/4" Q U W M E BUILT UP COLUMNS x 3 1/2" TITENS @ 16" 0 06 w Z c) � � coy BELOW O.C. MAX. FOR A -A PLAN VIEW 80 DEGREE TURN LANDING MASONRY NOTCHSTRINGRS DATQBE Q �( QO T.75 Z U1 °-a(D 0 � I- °U_Iw-- c NOTCHED AT LANDING U SEE SCHEDULE FOR MAX WIDTH OF LANDING w < O (3) 16d TOENAILS _ 0 = 2 (n w \ - NOT USED _ 0 z Q� C0� z E A35 @ EA. STRINGER TO LANDING SEE ARCHS. FOR MAX. RISE OF STEPS AND 3/4" O.S.B. W/ 8d NAILS MIN. TREAD DEPTH @ 3" O.C. TOP AND BOTTOM CHORD -77 77— I-JOIST PER FRAMING PLAN W/ SQUASH BLOCK OR BEAM/FLOOR TRUSS PER PLAN PENDING LANDING \ HEIGHT AND PLAN LAYOUT. HEADER WITHIN SUPPORT WALL COULD BE REQUIRED. SEE PLAN 2x12 STRINGERS ONE FOR REQUIRED ON EACH SIDE AND HEADER AND ONE @ MID -SPAN A SUPPORT A INFORMATION. A34 @ EA. STRINGER TO LANDING 2x ATTACHED TO 2x JOIST (P.T. IF STRINGER \ I ATTACHING TO Z I I I I MASONRY WALL) CONT I I I LEDGER w/ (3) 16d 2x12 STRINGERS ONE I I I NAILS @ 16" O.C. MAX. ON EACH SIDE AND I I I I TO EACH STUD. ((2) 1/4" ONE @ MID -SPAN I I I I x 3 1/2" TITENS @ 16" I I I / (2) 2X BEAM PER O.C. MAX. FOR MASONRY WALL) A35 CONNECTION I I I I SCHEDULE @ END OF LANDING FOR STRINGERS TO WOOD OR MASONRY 2X8 P.T. SPF #2 (MIN.) CONNECT TO. BEAM WALL SEE PLAN FOR LET -IN FASTEN TO TO BEAR DIRECTLY ON MORE INFO SLAB USING MIN. (4) 4" BUILT UP COLUMN 2x JOIST PER X 3" EVENLY SPACED BELOW. SCHEDULE TAPCONS @ MIN. END MIN. (3) 2x4 SPF #2 DISTANCE OF 1-1/2" COLUMN HEIGHT OF LANDING O Uw J Q L�� o �oQa � W U-W z Z 0UjN4< SEE ARCH PLAN 2x4 CONT. TOP PLATE O MAX. 4'-0" ABOVE FLOOR ATTACH TOP PLATE TO C) W STUDS W/ (2) 16d TOE 4 W 2x4 #2 SPF STUDS X X NAILS GUARDRAILS AND HANDRAILS, INCLUDING IN -FILL COMPONENTS, O.C. 2x4 SILL PLATE W/ () I 2x6 VERTICAL @ 6-0 22x4 #2 SPF STUDS @ SHALL BE CONSTRUCTED TO WITHSTAND A LIVE LOAD OF 50_PSF 10d NAILS @ 4" O.C. O.C. MIN. AND @ ANY 24" O.C. W/ (2) 12d AND A CONCENTRATED LOAD OF 200 PSF PER FBC R301 AND O (NOTCHED @ 2x6 I w OPENING W/IN TOENAILS BOTTOM TABLE R301.5 (FBC 5TH EDITION) � HANDRAIL VERTICAL LOCATIONS). NOTCH SILL PLATE FOR VERTICAL z KNEEWALL NOTCH SILL AND 0 PLYWOOD FLOORING Q TO ALLOW VERTICAL O 2x L-BRACE W/ 12d 2x6 VERTICAL AND TO SLIDE DOWN TO p Q 0 NAILS @ 4" O.C. L-BRACE @ 6'-0" O.C. & FACE OF TRUSS z O @ ANY OPENING 2x4 CONT. TOP PLATE _ 0000 11 ATTACH 2x6 VERTICAL (ATTACH TOP PLATE Q 04 TO STUDS W/ 2 16d G) TO TRUSS W/ (3) %a" x 3" 3 1/2" TOE NAILS O Z LU L. DOUBLE TRUSS PARALLEL TO FLOOR SDS WOOD SCREWS Z _J 0 SECTION X-X N.T.S. EQUALLY _ 0 W J SPACED/CENTERED IN 2x4 #2 SPF STUDS @ F- to W 2x4 CONT. TOP PLATE 2x4 CONT. TOP PLATE TRUSS TO OUTSIDE 24" O.C. EVERY OTHER ap �e ATTACH TOP PLATE TO 31" ATTACH TOP PLATE TO FACE OF TRUSS STUD TO BE p 0 STUDS 2/ (2) 16d TOE` STUDS W/ (2) 16d TOE ')IIII ATTACHED TO TRUSS ~ 0 0 NAILS NAILS I BELOW (OTHERWISE W 2x4 #2 SPF STUDS @ SEE ARCH PLAN I ATTACH W/ (2) 12d z 24" O.C. W/ (2) 12d MAX. 4'-0" ABOVE FLOOR TOENAILS @ BOTTOM) 0 Z TOENAILS BOTTOM 2x4 #2 SPF STUDS @ X X I W ~ j co SLICE CUT PLYWOOD 24" O.C. W/ (2) 12d I NOTCH FLOOR I 2x4 SILL PLATE W/ (2) W �• W 0 FLOORING FOR STRAP I 16d TOE NAIL EA. — TOENAILS BOTTOM I SHEATHING TO w ---) ACCOMMODATE 2x I CONT. BRACE & 10d 0 11-- CL H NAILS 4" O.C. TO 2x4 SILL PLATE W/ (2) @ f- ry 2x4 #2 SPF SILL PLATE NOTCH SILL AND I 10d NAILS @ 4" O.C. __:_ FLOOR SHEATHING U 11 W/ (2) 10d NAILS @ 4" PLYWOOD FLOORING I (NOTCHED @ 2x6 �`- O.C. TO ALLOW VERTICAL VERTICAL LOCATIONS). ATTACH 2x4 TO TRUSS U) STRUCTURAL ENG: RMG W/ 2 Y4 x3 SDS TO SLIDE DOWN TO I O � " Q DRAFTING: (2) SIMPSON LSTA24 FACE OF TRUSS I SCREWS EQUALLY P STRAP (1 EA. SIDE OF SPACED & CENTERED w STRUCT: JV STUD) EVERY 48" O.C. ATTACH 2x6 VERTICAL 2x6 VERTICAL AND """ IN TRUSS p - L-BRACE @ 6'-0" O.C. & QC CHECK: CC FLOOR BEAM CONDITION TO TRUSS W/ (3) Y4" x 3" @ANY OPENING W JOB No. TM - 2170194 FLOOR BEAM SEE SIDS WOOD SCREWS - - --- -- BASE PLATE PER FLOOR PLAN NOTE: PLAN EQUALLY U) SCALE: AS INDICATED ATTACHED PER PLAN 1. BASED ON MIN. TREAD DEPTH OF 10" AND MAX. RISER HEIGHT OF 7-3/4° SPACED/CENTERED IN TRUSS SEE PLAN--- 2. IF HEIGHT FALLS IN BETWEEN VALUES ROUND UP TO NEAREST HEIGHT TRUSS TO OUTSIDE DATE: 04/12/2017 3. (1) 2x12 BEAM IS REQUIRED AT THE OUTSIDE FACE OF THE LANDING FOR FACE OF TRUSS STRINGER ATTACHMENTS. SEE CHART FOR MIN. SIZE OF INSIDE BEAM. NAIL ST01 GEN. STAIR AND LANDING FRAMING DETAILS (2) PLY BEAM TOGETHER USING (2) 12d NAILS AT 4" O.C. rSTO3� HANDRAIL CONNECTION AT FLOOR TRUSSES SINGLE TRUSS PARALLEL TO FLOOR PERPENDICULAR TO FLOOR 3/4"=1'-0" 4. BEAM TO BEAR ON SUPPORT COLUMN W/ (3) 16d TOENAILS (BLOCK SOLID 3/4"=1'-0" N.T.S. UNDER BEAMS LESS THAN 2x12) ST1 COPYRIGHT MCD 2014: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. BEAM/JOISTS REQUIREMENT AT LANDING HEIGHT OF STAIRS BEAM JOISTS MAX WIDTH AT LANDING (#2 SYP) (#2 SYP) OF LANDING (3) 2x12 2x8 8'-0" 12'-0" (2) 2x12 2x6 6-0— (1) 2x12 (1) 2x8 2x6 4'-0" (3) 2x12 2x8 8'-0" 11'-0" (2) 2x12 2x6 6'-0" (1) 2x12 (1) 2x8 2x6 4'-0" (3) 2x12 2x8 8'4" 10'-0" (2) 2x12 2x6 6'-0" (1) 2x12 (1) 2x8 2x6 4'-0" (3) 2x12 2x12 9'-0" (2) 2x12 2x8 7'-0" g_0 (1) 2x12 (1) 2x8 2x6 5'-0" (3) 2x12 2x8 9'_0" (2) 2x12 2x8 _ 7 O1 (1) 2x12 (1) 2x8 2x6 5'-0" (3) 2x12 2x12 9'-0" (2) 2x12 2x8 T-0" T-0" (1) 2x12 (1) 2x8 2x6 5'-0" 6'-0" (2) 2x12 2x8 8'-0" (1) 2x12 (1) 2x8 2x6 5'4" 5'-0" OR LESS (2) 2x12 2x8 9'-0" (1) 2x12 (1) 2x8 2x6 6'-0 "