HomeMy WebLinkAbout3929 Saltmarsh Lp 18-910 (a)1. CONTRACTORS SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT SITE BEFORE CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO TO THE BUILDER FOR JUSTIFICATION AND/OR CORRECTION BEFORE CONTINUING WITH WORK. CONTRACTORS SHALL ASSUME RESPONSIBILITY FOR ERRORS THAT ARE NOT REPORTED TO THE BUILDER. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES, REGULATIONS, AND FHA/VA MPS. 3. ALL DIMENSIONS SHOULD BE READ OR CALCULATED AND NEVER SCALED. 4. ALL FOOTINGS TO BE BELOW FROST LINE (SEE LOCAL CODE) AND MUST REST ON UNDISTURBED SOIL CAPABLE OF HANDLING THE BUILDING LOAD. CONSULT LOCAL ENGINEER FOR PROPER FOOTING AND REINFORCING SIZES. 5. CONTRACTOR SHALL INSURE COMPATIBILITY OF THE BUILDING WITH ALL SITE REQUIREMENTS. 6. IF BACKFILL EXCEEDS 4' AGAINST ANY FOUNDATION WALL, REINFORCE AS PER CODE. 7. ALL WOOD, CONCRETE, AND STEEL STRUCTURAL MEMBERS SHALL BE OF A GOOD GRADE AND QUALITY AND MEET ALL NATIONAL, STATE, AND LOCAL BUILDING CODES WHERE APPLICABLE. 8. ALL FOUNDATION AND STRUCTURAL MEMBERS SHOULD BE VERIFIED AND STAMPED BY AN ENGINEER IN THE STATE WHERE CONSTRUCTION IS OCCURRING DUE TO A WIDE VARIANCE IN LOCAL CODES, SOIL BEARING CONDITIONS, FROST LINE DEPTH, GEOLOGICAL AND WEATHER CONDITIONS, ETC. 9. THE CONTRACTOR IS RESPONSIBLE FOR ADJUSTING AND VERIFYING ALL STRUCTURAL DETAILS AND CONDITIONS TO MEET ALL LOCAL CODES TO INSURE A QUALITY AND SAFE STRUCTURE. 10. EXTERIOR FINISHES: INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. -6TH EDITION (2017) RESIDENTIAL & ASTM C 1063. ALL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIAL, EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 1/2 INCH 11 GAUGE NAILS HAVING A 7/16 INCH HEAD, OR 7/8 INCH LONG 16 GAUGE STAPLES SPACED NO MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED. THICKNESS OF TEXTURED FINISH OVER FRAME APPLICATION TO FLORIDA BUILDING CODE 6TH EDITION ( 2017) RESIDENTIAL AND ASTM C 926. WEEP SCREEDS SHALL BE A MINIMUM OF NO. 26 GALVANIZED SHEET GAUGE CORROSION - RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES SHALL BE PROVIDED AT OR BELOW THE PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE PAVED AREAS. THE WEATHER RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED, PER F.B.C.R.:6TH EDITION ( 2017) RESIDENTIAL WATER RESISTIVE BARRIERS INSTALLED OVER WOOD BASED SHEATHING SHALL INCLUDE A WATER RESISTIVEVAPOR PERMEABLE BARRIER EQUIVALENT OT 2 LAYERS OF GRADE D PAPER. STUCCO APPLICATION AND CURING PER FLORIDA BUILDING CODE 6TH EDITION ( 2017) RESIDENTIAL OR IN ACCORDANCE WITH ASTM C 926. tv I 2 2 6 0 — I � eko"M SQUARE FOOTAGE TABULATIONS �®G E Irl g. UNHEATED S.F. FIRST FLOOR °°• MULHERN+KULP° Na 77624 PORCH residential structural engineeringOF TOTAL °„ 0 South Maple Street Suite 150 • Ambler, PA 19002. 215.645.6001 W T i mulhemkulp.com Jcc W � O O CO SQUARE FOOTAGE TABULATIONS ' HEATED S.F. UNHEATED S.F. FIRST FLOOR SECOND FLOOR TOTAL GARAGE PORCH PATIO/COVERED PATIO TOTAL C W T i W N Jcc W � O O CO N � N ELEVATION ' U' 1002 1258 2260 411 48 80 539 LOT 175 Oct W UE DATE: FOR REVIEW REVISIONS: These drawings are the property of Ashton Woods Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2015 Ashton Woods Homes LAST REVISION o cc LAST SAVED BY: Q ' J J Uj 0 QC C W T i W N Jcc W � O O CO N � N Z a J SHEET NO: FL T=1 i, GENERAL FOUNDATION NOTES: -THIS PERIMETER DIMENSION PLAN IS FOR DIMENSIONAL INFORMATION ONLY. - SLOPE ALL STOOPS AND HARDSCAPE MATERIAL AWAY FROM BUILDING - TYPICAL. - SLOPE GARAGE FLOOR 1/8" PER FOOT TO GARAGE DOOR OPENING. - VERIFY CURB CUT BLOCKOUT WITH GARAGE DOOR MANUFACTURER. - REFER TO CIVIL DRAWINGS FOR FINISH SURFACE ELEVATIONS. - FINISH GRADE SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. REFER TO SOILS REPORT FOR ANY SPECIFIC REQUIREMENTS. - REFER TO STRUCTURAL DRAWINGS FOR HOLDDOWNS, FOOTING DETAILS, CURB THICKNESS, AND INFORMATION NOT SHOWN ON THIS PLAN. - PLUMBING FIXTURES, VENT LOCATIONS, ETC. ARE APPROXIMATE. CONTRACTOR TO VERIFY COUNT AND LOCATION. - VERIFY THE SUPPLY FOR SEPARATE CONDUITS TO ANY ISLAND FOR GAS, WATER OR ELECTRIC. - VERIFY ALL DOOR THRESHOLD HEIGHTS TO HARD SURFACES. 7 3/4" MAX AT INSWING DOORS. - TYP STOOP AT INSWING/SLIDER DOORS: 36" DEEP BY THE WIDTH OF THE DOOR SERVED, MINIMUM. (PER 2017 FLORIDA RESIDENTIAL BUILDING CODE) PROVIDE A SLIP -RESISTANT FINISH. - FOR THE USE OF EXPOSED GAS WATER HEATERS IN THE GARAGE, PROTECT THE WATER HEATER WITH 3" DIA CONCRETE FILLED STEEL PIPE EMBEDDED INTO CONCRETE FOOTING. - WOOD CONTACTING CONCRETE OR MASONRY OR LESS THAN CODE REQUIRED SEPARATION TO GRADE SHALL BE PRESSURE TREATED OR FOUNDATION GRADE REDWOOD. SET ALL EXTERIOR WALL SILLS IN MASTIC. FOUNDATION KEYNOTE LEGEND F1 LINE OF SLAB ABOVE F2 I LINE OF FRAMED WALL ABOVE IIIIIF •. o ..•� No 77824 MULHERN+KULP '�• ��� residential structural engineering m:tea a, ZA.20 South Maple Street Suite 150 • Ambler, PA 19002p 215.646.8001 mulhemkulp.com o®e ndrorltwedny Hpirlanrdredbolbrda�lnea' 28'-0" 2'-0" 10'-0" 16'-0" 20'-8" 28'-0" SLAB PLANU 1 1/4" = V-0" AT 22"X34" LAYOUT 1/8"= V-0" AT 11 " X 17" LAYOUT 7'-4" ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2016 Starlight Homes LAST REVISION LAST SAVED BY: -Z a PATIO SLAB W � J J Uj REINFORCE PER LOCAL p w Q Z CODE AND ENGINEER'S j �- J o � BO Q y SPECIFICATIONS ° W N Z IVA MAIN SLAB J a T NOTE: EXTERIOR WALLS ARE DIMENSIONED TO OUTSIDE FACE. GRADE BEAMS AND APPLIANCES '- ARE DIMENSIONED TO CENTER LINE. N 0 VERIFY UNDERSLAB T CONDUIT AT N KITCHEN ISLAND I a I� NJt T III I ::.::::::::::.......:::::::::::.:J........,..........�.«:::''....`............. `-n .......................................1 10'-2 1/2" 9'-11 1/4" T-10 1/4" co .. . i i 00 i........i 6 CO I 0 I CV 14 LL. . ...... WH)CV 0 T 3'-0" 17'-0" 0 6"-01" 20'-0" a 0 J. PORCH SLAB REINFORCE PER LOCAL w s U) • t CODE AND ENGINEER'S ' `�o� N SPECIFICATIONS o0 " r GARAGE SLAB T REINFORCE PER LOCAL 1'-4" 4'-8" V -4 - CODE AND ENGINEER'S SPECIFICATIONS T F1 20'-8" 28'-0" SLAB PLANU 1 1/4" = V-0" AT 22"X34" LAYOUT 1/8"= V-0" AT 11 " X 17" LAYOUT 7'-4" ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2016 Starlight Homes LAST REVISION LAST SAVED BY: -Z a J J Uj Q Z Z J J � m J Q y toN N Z Q J �J SHEET NO: FL 0.1.3 FLOOR PLAN KEYNOTE LEGEND 1 HOUSE TO GARAGE FIRE SEPARATION, GARAGE/HOUSE SEPARATION AT VERTICAL SURFACES SHALL BE PROTECTED WITH ONE (1) LAYER 1/2" GYPSUM BOARD. GARAGE/HOUSE SEPARATION AT HORIZONTAL SURFACES SHALL BE PROTECTED WITH ONE (1) LAYER 5/8" TYPE "X" GYPSUM BOARD 2 HOUSE TO GARAGE DOOR SEPARATION. PROVIDE 1 3/8" SOLID CORE DOOR W/ SELF CLOSING HINGE OR APPROVED 20 MINUTE RATED DOOR 3 BENEATH STAIRS AND LANDINGS. 1/2" GYPSUM BOARD ON WALLS AND CEILING OF ENCLOSED ACCESSIBLE AREAS 8 ATTIC ACCESS LARGE ENOUGH TO REMOVE LARGEST PIECE OF EQUIPMENT BUT NOT LESS THAN 30"X22". FIRE RATED ACCESS AS NOTED. ATTIC ACCESS LADDER, VERIFY LOCATION AND SIZE WITH TRUSSES (25 1/2"X54" SIZE 11 HALF WALL, HEIGHT AS NOTED 12 INTERIOR SOFFITS: FFL = 8'-1" U.N.O. SFL = 7'-6" U.N.O., OPT. CASED OPENING U.N.O. 13 SHOWER, TEMPERED GLASS ENCLOSURE 14 TUB -SHOWER COMBO 16 SLIDE -1N ELECTRICAL RANGE W/ HOOD AND MICRO ABV. VENT PER MANUFACTURER'S WRITTEN INSTRUCTIONS N 1 i` T N N N 28'-0" 2'-0" 10'-011 16'4" 11 1 PATIO 4 6'-0" 6080 S.G.D. VERIFY LOCATION IN FIELD 8'-01, A/C 3'-011 31-011 31-4,1 3050 SH O 30750 SH �7 GARAGE N 16070 SECTIONAL w o No 778®; r MULHERN+KULP 4 residential structural engineering _01. �7m4 1; 20 South Maple Street, Suite 150 • Ambler, PA 19002 TA F p215.646.8001 • mulhemkulp com ���� � ° .10 Miibm+ myndAr nat balh�abdplrs. N J Uj 0N C? 2 2 5, J a � O LL c0 N 1 Z Q J CL M. BED LOFT �r ;0 c C L 9 00 i� T F N T T N N N 28'-0" 2'-0" 10'-011 16'4" 11 1 PATIO 4 6'-0" 6080 S.G.D. VERIFY LOCATION IN FIELD 8'-01, A/C 3'-011 31-011 31-4,1 3050 SH O 30750 SH �7 GARAGE N 16070 SECTIONAL w o No 778®; r MULHERN+KULP 4 residential structural engineering _01. �7m4 1; 20 South Maple Street, Suite 150 • Ambler, PA 19002 TA F p215.646.8001 • mulhemkulp com ���� � ° .10 Miibm+ myndAr nat balh�abdplrs. CV PORCHCO /777T SOFFIT SEE EXT. ELEV. 2'-411 16'-0" L 2'-4" 1'-4" 41-811 11-411 20'-8" 7'-411 28'-0" FI RST FLOOR PLAN ELEVU i 1 1 /4" = V-0" AT 22"X34" LAYOUT 1 /8"= V-0" AT 11 " X 17" LAYOUT N 8'-1" CLG. 8'-1" CLG. � °' iv T � r BED 4 T M T 8'-1" CLG. LO WIC 8'-1" CLG. 2468 30 0 SH 30 0 SH 30 0 SH V-5" 5'-31 /2" 2'-31 /2" 2'-0" 5'-7" I 6'-5" 11'-8 1/2" 4'-3 1/2" I 12'-0" 0 28'-0" T I L------------------------------- j SECOND FLOOR PLAN ELEVU 2 1/4" = V-0" AT 22"X34" LAYOUT 1/8% V-0" AT 11 " X 17" LAYOUT 0 r W 0 Z t� ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2016 Starlight Homes LAST REVISION LAST SAVED BY: Q' J J Uj 0N 2 2 5, J a � O LL N N' Z Q J CL M. BED LOFT 8'-1" CLG. 8'-1" CLG. c �r T 00 F 9 1/2" x T-0" 6'-3 1/2" 5'-71 L 3'-5 1/2" 5'-3 1/2" T-61/2" 2868 tl dM 2868Z r Z U? 2468 to iv ¢ 2868 17� 1 LA HVAC — — - M. BA 8'-1" C ?468 - - - `c�� 8'-1" CLG. N - - - - - co c'? `n 13 SLIDING BYPASS — [i— Mrd 14 ° - - - io 4"X60" DOOR ih 32"X60" 9'-31 /2" 2'-511 T-21 /2" BA 3 - - - - Cv 00 81-1111C L --- '- - o0 LINEN 1 U-) —, I 068 z I— --- — — N i WIC r 8 -°^Q 8'-1" CLG. 122 I i rn 2468 b LO ` LO 11' 8 1/2" 4'-3 1/2" 21-41/211 - L------ — — — — — — — —- 468 - - - - 2868 . N 2868 M BED 3 2466 WIC e CV PORCHCO /777T SOFFIT SEE EXT. ELEV. 2'-411 16'-0" L 2'-4" 1'-4" 41-811 11-411 20'-8" 7'-411 28'-0" FI RST FLOOR PLAN ELEVU i 1 1 /4" = V-0" AT 22"X34" LAYOUT 1 /8"= V-0" AT 11 " X 17" LAYOUT N 8'-1" CLG. 8'-1" CLG. � °' iv T � r BED 4 T M T 8'-1" CLG. LO WIC 8'-1" CLG. 2468 30 0 SH 30 0 SH 30 0 SH V-5" 5'-31 /2" 2'-31 /2" 2'-0" 5'-7" I 6'-5" 11'-8 1/2" 4'-3 1/2" I 12'-0" 0 28'-0" T I L------------------------------- j SECOND FLOOR PLAN ELEVU 2 1/4" = V-0" AT 22"X34" LAYOUT 1/8% V-0" AT 11 " X 17" LAYOUT 0 r W 0 Z t� ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2016 Starlight Homes LAST REVISION LAST SAVED BY: Q' J J Uj 0N 2 2 5, J a � O LL N N' Z Q J CL SHEET NO: FL 13 o" SG.���®�� " ° • o° Na 77824 MULHERN+KULP `® residential structural engineering `33 : TA F .' 4£1 20 South Maple Street Suite 150 • Ambler, PA 19002 ��,���4e�m p 215.646.6001 • mulhe►nkulµco►u Mukm+ iqr aywlMa ��era�ea■yanx re4meamolherdx�nin 2NDFLOOR PL. HT. — — _XXXXXXXXXXXXXXXAXAAAAAAAMMABXMMAARAAAAAAAAAAAAAAAAAAAAAAAAA J J W a z 2ND FL. WDW. HT. — — — — — — — — — — — — — — — N Z Q J BED 4 / LOFT r T `, T 8'-1" CLG. \ 8'-1" CLG. 00 W 0 \ / " 2ND FLOOR FIN. FLR. N 1ST FLOOR PL. HT. —- 1 ST FL. WDW. HT. FAMILY W-4" CLG. 1111 , :Y a IST FLOOR FIN. FLR. - — ................. ......... �............. �............... ,moi ISI I ISI I L ` 1 I I _ III- ►►.....I,, .__.. - _._.i 1_111... I III II Y.......�..... ........ � ._..__ II 11............ ........ ... 1111 1111 ..: .. ........... � �.... ! I 1 ► I - ; .___._., ► i- .! ► i- ,. 1 .............. I ..........I .................. ............ ................... _ I� I L - - - - ; , I IL �, , i` ► � �� � �_ ..... �...-...1111._------- .... ............. I ---I I ; I � � � � � !_...�.., ((._..._.V. � IL.........Il....:..... III......II. I I I _ -� - ► � ._ _1111. .�..._. . ► .III.. ... ...............�i�._. 1111......... ..... . ., I ............ .......: .:.....L ; : BUILDING ....I -jII., SECTION 'U' ............ ............ ................ --- ��-iii- I�� ,.. 1 1/4" = 1'-0" AT 22"X34" LAYOUT 1/8"= 1'-0" AT 11" X 17" LAYOUT LU Iirlrrw I Oct C ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: T These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. 0 2016 Starlight Homes LAST REVISION LAST SAVED BY: a J J W a z CO s J v � W Cl) 0 (DN N Z Q J SHEET NO: FL 4.2 ALL WINDOWS WHOSE OPENING IS LESS THAN 24" ABOVE THE FINISH FLOOR AND WHOSE OPENING IS GREATER THAN 72" ABOVE THE OUTSIDE WALKING SURFACE MUST HAVE WINDOW OPENING LIMITING DEVICES COMPLYING WITH THE FLORIDA BUILDING CODE 6TH EDITION ( 2017) RESIDENTIAL NOTES: -GRADE CONDITIONS MAY VARY FOR INDIVIDUAL SITE FROM THAT SHOWN. BUILDER SHALL VERIFY AND COORDINATE PER ACTUAL SITE CONDITIONS. -WINDOW HEAD HEIGHTS: 1 ST FLOOR = 7'-4" U.N.O.ON ELEVATIONS 2ND FLOOR = T-1" U.N.O.ON ELEVATIONS 3RD FLOOR = 7'-0" U.N.O.ON ELEVATIONS. -ROOFING: PITCHED SHINGLES PER BUILDER. No 77524 m 144MULHERN+KULPq° b° residential structural engineering '° T F :'44,1 20 South Maple Street, Suite 150 • Ambler, PA 19002 0•a.a7te�o P215.646.8001 • mu/hemkulpcom®�°�," 0 rot ffitnd*V*aYIa tlon*Wmdw�cpNw. ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. 0 2016 Starlight Homes LAST REVISION LAST SAVED BY: Z Q ELEVATION KEYNOTE LEGEND J E9 CORROSION RESISTANT ROOF TO WALL FLASHING, CODE COMPLIANT FLASHING MUST BE INSTALLED AT ALL ROOF/WALL INTERSECTIONS Ell DECORATIVE WROUGHT IRON, SEE DETAILS E13 FIBER CEMENT LAP SIDING PER DEVELOPER W/ 5/4x4 CORNER TRIM BOARDS E15 FIBER CEMENT PANEL SIDING W/ 1X3 BATTS AT 12" O.C. (VINYL BOARD AND BATTEN SIDING) E16 1X FIBER CEMENT TRIM OR EQUAL, U.N.O. SIZE AS NOTED E17 FALSE WOOD/VINYL SHUTTERS, TYPE AS SHOWN, SIZE AS NOTED E19 a E22 w No 77524 m 144MULHERN+KULPq° b° residential structural engineering '° T F :'44,1 20 South Maple Street, Suite 150 • Ambler, PA 19002 0•a.a7te�o P215.646.8001 • mu/hemkulpcom®�°�," 0 rot ffitnd*V*aYIa tlon*Wmdw�cpNw. ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. 0 2016 Starlight Homes LAST REVISION LAST SAVED BY: Z Q J J W a N O J a � w O W �D N N Z Q I� SHEET NO: FL 5.3 12 5� N V ui 12 �5 LEFT ELEVATIONU 2 1 /4" ='V-0' AT 22"X34" LAYOUT 1 /8 V-0" AT 11 " X 17" LAYOUT CD WW J 0 ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2016 Starlight Homes LAST REVISION LAST SAVED BY: Z ELEVATION KEYNOTE LEGEND Q E9 CORROSION RESISTANT ROOF TO WALL FLASHING, CODE COMPLIANT FLASHING MUST BE INSTALLED AT ALL ROOF/WALL INTERSECTIONS E11 DECORATIVE WROUGHT IRON, SEE DETAILS E13 FIBER CEMENT LAP SIDING PER DEVELOPER W/ 5/4x4 CORNER TRIM BOARDS E15 FIBER CEMENT PANEL SIDING W/ 1X3 BATTS AT 12" O.C. (VINYL BOARD AND BATTEN SIDING) E16 1X FIBER CEMENT TRIM OR EQUAL, U.N.O. SIZE AS NOTED E17 FALSE WOODNINYL SHUTTERS, TYPE AS SHOWN, SIZE AS NOTED E19 Cl) O R2271 Q 12 5� N V ui 12 �5 LEFT ELEVATIONU 2 1 /4" ='V-0' AT 22"X34" LAYOUT 1 /8 V-0" AT 11 " X 17" LAYOUT CD WW J 0 ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2016 Starlight Homes LAST REVISION LAST SAVED BY: Z Q J J W QC G Cl) O J Q � W W N N Z Q J a� 0 SHEET N0: FL 5.3.1 1/150 RATIO: 1/300 RATIO: GENERAL CONTRACTOR SHALL VERIFY THE AS AN ALTERNATE TO THE 1/150 RATIO LISTED, THE NET NET FREE VENTILATION OF THE VENT FREE CROSS -VENTILATION AREA MAYBE REDUCED TO 1/300 PRODUCT SELECTED BY OWNER. VERIFY WITH WHEN A VAPOR BARRIER IS HAVING A TRANSMISSION RATE MANUFACTURER OF HIGH AND LOW VENTS TO NOT EXCEEDING [-PERM INSTALLED ON THE WARM -IN - BE USED FOR MINIMUM CALCULATED VENTS WINTER SIDE OF THE CEILING. REQUIRED. THE REQUIRED VENTILATION SHALL BE MAINTAINED. PROVIDE INSULATION STOP GENERAL CONTRACTOR SHALL VERIFY THE NET FREE SUCH THAT INSULATION DOES NOT OBSTRUCT VENTILATION OF THE VENT PRODUCT SELECTED BY FREE AIR MOVEMENT AS REQUIRED BY THE OWNER. VERIFY WITH MANUFACTURER OF HIGH AND LOW BUILDING OFFICIAL. VENTS TO BE USED FOR MINIMUM CALCULATED VENTS CD REQUIRED. THE REQUIRED VENTILATION SHALL BE ALL OVERLAP FRAMED ROOF AREAS SHALL MAINTAINED. PROVIDE INSULATION STOP SUCH THAT HAVE OPENINGS BETWEEN THE ADJACENT INSULATION DOES NOT OBSTRUCT FREE AIR MOVEMENT AS ATTICS IN THE ROOF SHEATHING (AS ALLOWED REQUIRED BY THE BUILDING OFFICIAL. BY THE STRUCTURAL ENGINEER) TO ALLOW PASSAGE AND ATTIC VENTILATION BETWEEN ALL OVERLAP FRAMED ROOF AREAS SHALL HAVE OPENINGS THE TWO OR ISOLATED ATTIC SPACES SHALL BETWEEN THE ADJACENT ATTICS IN THE ROOF SHEATHING BE VENTED INDEPENDENTLY TO MEET 52017 (AS ALLOWED BY THE STRUCTURAL ENGINEER) TO ALLOW FLORIDA BUILDING CODES. PASSAGE AND ATTIC VENTILATION BETWEEN THE TWO OR ISOLATED ATTIC SPACES SHALL BE VENTED PER DEVELOPER, AT ALL CANTILEVERED INDEPENDENTLY TO MEET 2017 FLORIDA BUILDING CODES. FLOORS, CANTILEVERED ARCHITECTURAL POP - OUTS, AND ANY DOUBLE FRAMING PER DEVELOPER, AT ALL CANTILEVERED FLOORS, PROJECTIONS THAT ARE SEPARATED FROM CANTILEVERED ARCHITECTURAL POP -OUTS, AND ANY THE VENTING CALCULATIONS SHOWN ABOVE, DOUBLE FRAMING PROJECTIONS THAT ARE SEPARATED PROVIDE A CONTINUOUS 2" CORROSION FROM THE VENTING CALCULATIONS SHOWN ABOVE, RESISTANT SOFFIT VENT AT UNDERSIDE OF PROVIDE A CONTINUOUS 2" CORROSION RESISTANT SOFFIT FRAMED ELEMENT. VENT AT UNDERSIDE OF FRAMED ELEMENT. NOTES: ALL ROOF DRAINAGE SHALL BE PIPED TO TRUSS MANUFACTURER SHALL SUBMIT STRUCTURAL CALCS STREET OR APPROVED DRAINAGE AND SHOP DRAWING TO THE BUILDER'S GENERAL FACILITY. CONTRACTOR AND BUILDING DEPARTMENT FOR REVIEW DASHED LINES INDICATE WALL BELOW. PRIOR TO FABRICATIONS. LOCATE GUTTER AND DOWNSPOUTS PER ALL PLUMBING VENTS SHALL BE COMBINED INTO A MINIMUM BUILDER. AMOUNT OF ROOF PENETRATIONS. ALL ROOF PENETRATIONS PITCHED ROOFS AS NOTED. SHALL OCCUR TO THE REAR OF THE MAIN RIDGE. ROOF VENT CALL. ELEV. 'U' Name Area 1/300 RATIO AT HIGH & LOW 1/150 RATIO AT HIGH & LOW AREA 1 1311 SF 314.72 int 629.44 int AREA 2 141 SF 33.89 int 67.79 inz TN EA1 ,,, ROOF PLANU 1 11,V = 1'-0" FAT LAYOUT 1 /8"= V-0" AT 11 " X 17" LAYOUT G" MULHERN+KULP[AraNo4 residential structural engineeringOJ 20 South Maple Street, Suite 150 - Ambler, PA 19002 %. T F : p215.M.9001 • mulhemkulp.com��� ° O ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2016 Starlight Homes LAST REVISION LAST SAVED BY: J SHEET N0: FL 5.3.2 Q J J W 0Q 2 = Z a J IL LL � 0 O CD (0 N N Z a J 001t_ J SHEET N0: FL 5.3.2 WALL CABINET cc FLOOR UTILITYU 1 J 1/4" = 1'-0" AT 22"X34" LAYOUT 1/8"= 1'-0" AT 11"X.17" LAYOUT 0Q N Z J J a J N 0- P OO Z J a E. O in Q N W U' Z X LL Do S O 2 Gr x 0 Z LL 30" HIGH VANITY _ O �a BASE CABINET "' 3 a 2 O U. o o o co o m iV W W �� IC 3 O m p � v W W r r O m a 5 a S coU a (3 O n ZZQ N N LLU. W 2 ,� Z SO W OO • PROVIDE GROUNDING ELECTRICAL ROD PER LOCAL CODES. S aLU ZW CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. p A Lr p 8 - ALL EXHAUST FANS SHALL HAVE BACKDRAFT DAMPERS. Q ~ O = U LU - ELECTRICAL SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE Z �OQQ CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT. Q - PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AND CO2 DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. O LL - PROVIDE AND INSTALL GROUND FAULT CIRCUIT -INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRICAL 9W CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. - ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS. c7 - HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. O It ALL ELECTRICAL AND MECHANICAL EQUIPMENT (FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. - PROVIDE POWER, LIGHT AND SWITCH AS REQUIRED FOR ATTIC FURNACE PER CODE AND MANUFACTURER'S STANDARD ELECTRICAL BOX HEIGHTS WALL CABINET cc FLOOR UTILITYU 1 J 1/4" = 1'-0" AT 22"X34" LAYOUT 1/8"= 1'-0" AT 11"X.17" LAYOUT 0Q N Z J J a J N 0- P OO Z a E. O in Q N W Do O 2 Gr x Z LL 30" HIGH VANITY _ O BASE CABINET "' CABINET CO 2 O co iV IC 3 O m SWITCH AND RECEPTACLE BOXES SWITCH AND RECEPTACLE BOXES OVER BATH CABINETS OVER KITCHEN CABINETS NOTES: • PROVIDE GROUNDING ELECTRICAL ROD PER LOCAL CODES. - PROVIDE AND INSTALL ARC FAULT CIRCUIT -INTERRUPTERS (AFCI) AS REQUIRED BY NATIONAL ELECTRICAL CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. - ALL EXHAUST FANS SHALL HAVE BACKDRAFT DAMPERS. - FAN/LIGHTS IN WET/DAMP LOCATIONS SHALL BE LABLED "SUITABLE FOR WET OR DAMP LOCATIONS." - ELECTRICAL SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT. - PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AND CO2 DETECTORS AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. - PROVIDE AND INSTALL GROUND FAULT CIRCUIT -INTERRUPTERS (GFI) AS REQUIRED BY NATIONAL ELECTRICAL CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. - ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS. - HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (FURNACES, A/C UNITS, ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP, AND WATER HEATERS) ARE SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. - PROVIDE POWER, LIGHT AND SWITCH AS REQUIRED FOR ATTIC FURNACE PER CODE AND MANUFACTURER'S WRITTEN INSTRUCTIONS. - PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AND CO2 DETECTORS. UNIT MUST BE HARDWIRED, INTERCONNECTED AND PROVIDED WITH BATTERY BACKUP. LEGEND: ©H CHIMES DUPLEX OUTLET -(� CEILING MOUNTED INCANDESCENT Y LIGHT FIXTURE � �/ CEILING FAN O (PROVIDE ADEQUATE SUPPORT) 4 PUSHBUTTON SWITCH EXTRA DUTY WEATHERPROOF GFI WP/GFI DUPLEX OUTLET' i J� WALL MOUNTED INCANDESCENT 110V SMOKE DETECTOR HARDWIRED AND INTER - SD CONNECTED W/ BATTERY /J CEILING FAN WITH INCANDESCENT GFI GROUND -FAULT CIRCUIT -INTERRUPTER DUPLEX OUTLET LIGHT FIXTURE BACK-UP// LIGHT FIXTURE // \ (PROVIDE ADEQUATE SUPPORT) FIXTURE CO2 DETECTOR RECESSED INCANDESCENT LIGHT AND INTER- �/ v OR CEILING MOUNTED L.E.D. FIXTUREHARDWIRED (VP) - VAPOR PROOF © CONNECTED W/ BATTERY HALF -SWITCHED DUPLEX OUTLET BACK-UP O EXHAUST FAN (VENT TO EXTERIOR) (D THERMOSTAT GAS SUPPLY WITH VALVE 220V 220 VOLT OUTLET J REINFORCED JUNCTION BOX�H EXHAUST FAN/LIGHT COMBINATION TELEPHONE �HB HOSE BIBB (VENT TO EXTERIOR) O TELEVISION WALL SWITCH __+CW 1/4" WATER STUB OUT ELECTRIC METER 3 THREE-WAY SWITCH FLUORESCENT LIGHT FIXTURE LZIM ELECTRIC PANEL 4 FOUR-WAY SWITCH TECH HUB SYSTEM n6 DISCONNECT SWITCH WALL SCONCE WP/G U W Z Z O U WP/GFI AT o A/C COND. a 7 A - FIRST FLOOR UTILITYU 1 J 1/4" = 1'-0" AT 22"X34" LAYOUT 1/8"= 1'-0" AT 11"X.17" LAYOUT SERVICE PANEL/ ELECTRIC METER TELEPHONE/ TELEVISION SERVICE BOX /GFI M. BED 8'-1" CLG. LOFT 8'-1" CLG. - 1 CD� I n 1 L ----------------------------J SECOND FLOOR UTILITYU 2 1/4" = 1'-0" AT 22"X34" LAYOUT 1/8"= V-0" AT 11" X 17" LAYOUT CZ W ..j 2 0 Z ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: These drawings are the property of Starlight Homes and are not to be utilized for construction, or copied in part or in whole without permission from the builder. © 2016 Starlight Homes LAST REVISION LAST SAVED BY: __T__ Z Q J J W 0Q N Z J J a J N N Z a a 0 SHEET NO: FL 6.1.2 ag,�G�k4�tiG(g ., CZ No 77524 MULHERN+KULPµ residential structural engineering °® ST I 0 -n� 20 South Maple Street, Suite 150 • Ambler, PA 19002 ®`° '•° tl°° p215.646.8001 • mulhemkulp.wm®(�6V 1 Mu�am+Ifub aiumeaiy.dha naierkiwdrryanaYdanpNonrebbeaaa�adxprbe. �"""" ISSUE DATE: 10.02.17 FOR REVIEW REVISIONS: a 2X EXT. BEARING WALL WEATHER RESISTANT BARRIER -TYPAR RUNG TO 1 1/2" BELOW TOP OF BLOCK HARDIE BOARD ;J HORIZ. SIDING These drawings are the ` HOUSE WRAP property of Starlight EXTERIOR SHEATHING Homes and are not to be utilized for construction, or copied in part or in whole without permission from ,.r the builder. © 2016 Starlight Homes LAST REVISION RIM JOIST Z -FLASHING LAST SAVED BY: HARDIE TRIM, BOTTOM SITS 1 1/2" BELOW TOP OF BLOCK a J J 4 J -CHANNEL STUCCO STOP 5/8" TEXTURED STUCCO OVER BLOCK 14 O (10 N HORIZ. BOARD SIDING DETAIL W/ N STUCCO PERPENDICULAR TO � Z WALL FL. TRUSSES Q 1J3" = 1'-0" AT 22"X34" LAYOUT = 1'-0" AT 11 " X 17" LAYOUT am SHEET NO: D-1 CONNECTION SPECIFICATIONS (TYP. U.N.O.) 140 MPH DESCRIPTION OF BLDG. ELEMENT 3"4.131" NAILS 3x0.120" NAILS J015T TO 50LE PLATE (3) TOENAILS (3) TOENAILS* 50LE PLATE TO J015T/BLK'G. (1) NAIL 0 4" o.c. (1) NAIL 0 4" ox.. STUD TO 50LE PLATE 2 TOENAILS (3) TOENAIL5* TOP OR SOLE PLATE TO STUD 2 NAILS 3 NAILS RIM TO TOP PLATE TOENAILS 0 8" o.c. TOENAILS 0 6" 0.0 BLK'6. BTWN, JOISTS TO TOP PL (3) TOENAILS (3) TOENAILS* DOUBLE STUD NAILS 0 24" o.c. NAILS 0 16" o.c. DOUBLE TOP PLATE NAILS 0 24" o.c. NAILS 0 1611 o.c. DOUBLE TOP PLATE LAP SPLICE NAILS IN LAPPED AREA II NAILS IN LAPPED AREA TOP PLATE LAP a CORNERS 4 INTER5EGTIN6 WALLS (2) NAILS (2) NAILS * 211/2"x0.113 15 AN ACCEPTABLE ALTERNATIVE TO A 3"x0.120", SAME SPACING OR NUMBER OF NAILS. (ONLY AGGEPTABLE WHERE * ARE SHOWN) Window $ Door Allowable Wind FPre55ure5 140 MPH Wind Zone Ex o5ure G OPENING 51ZE INTERIOR ZONES END ZONES 8' Garage Door +25.1 P5F/-28.4 PSF +25.1 PSF/-28.4 PSF 16' Garage Door +24.1 PSH -26.8 P5F +24.1 PSF/-26.8 P5F 10 5QFT. +28.6 P5F/-31.2 P5F +28.8 P5F/-38.5 P5F 20 5QFT. +21.5 PSP/ -21.1 P5F +21.5 P5F/-35.1 P5F 50 SOFT. +25.8 PSF/-28.3 PSF +25.8 PSF/-32.5 PSF 100 5QFT. +24.5 PSF/-26.1 PSF +24.5 PSF/-21.1 PSF 500 SOFT. +21.5 P5F/-23.1 P5F +21.5 P5F/-23.1 P5F (DEnd Zone Is defined as the smaller of 10% of least horiz. dim. or 40% of mean roof height, but not less than 4961 of least horiz. dim. or 3 ft. d- BEARING CONDITION QD N O I HO -1 II � O SIMPSON MSTGbb STRAP TIE (24" END LENGTH) (M5TGb(b83 ALTERNATE) (15, FLOOR FRAMING • I-J015TS/TRU55ES SHALL BE DESIGNED BY MANUF. TO MEET OR EXCEED L/460 LIVE LOAD DEFLECTION CRITERIA. • ALL METAL HANGERS SHALL BE 5PEGIFIED BY I-JO15T /TRU55 MANUFACTURER, UNLE55 OTHERWISE NOTED. • I-J015T/TRU55 SHOP DWGS. SHALL BE SUBMITTED TO ARCH. 4 ENG, FOR REVIEW AND APPROVAL PRIOR TO FABRICATION OR DELIVERY. • FLOOR 5HEATHING SHALL BE 23/32" GONFORMING TO P52-04, 24" O.G., EXP05URE 1, TONGUE AND GROOVE EDGES, FASTEN 5HEATHIN6 TO FRAMING MEMBERS W/ GLUE AND 3"x0.131" NAILS 0 b" O.G. AT PANEL EDGES 4 12" O.G. AT INTERMEDIATE SUPPORTS. EXTERIOR � SHEAR WALL 5HEATHIN6 SPEGIFIGATIONS INDIGATE5 LOCATION AND EXTENT OF 5HEARWALL WHIGH REG2UIRE5 SHEATHING AND/ OR FA5TEN I NG 5PEG I E I GAT I ON5 BEYOND THAT OF 5TANDARD GON5TRUGTION SYMBOL SHEAR PANEL 5PEG. -INV PLYWOOD OR 05B FASTENED w/ PI 2Y2 "x0.131" NAILS © 6" o.C. ALONG PANEL ED6E5 AND 12" o.C. IN THE PANEL FIELD. 1/16" PLYWOOD OR 055 FA5TENED w/ P3 2Y2"x0.131 " NAILS @ 3" o.C. ALONG PANEL E1?6E5 AND 12" o.C. IN THE PANEL FIELD. STANDARD EXTERIOR WALL 5HEATHING REQUIREMENT5: SHEATH ALL EXTERIOR WOOD FRAMED WALLS w1.7/16" PLYWOOD OR 0513 FASTENED w/ 2A`"x0.131" NAILS o 6" O.G. AT ALL PANEL E06E5 AND 0 12" O.G. AT GENTER. (U.N.O. ON PLANS) I. ALL PANEL E06E5 SHALL OCCUR OVER FRAMING OR 2X BLOGKIN6 SHALL BE PROVIDED TO SUPPORT PANEL EDGE AND FASTENING 2. ALL 5TRUGTURAL PANELS ARE TO BE DIRECTLY APPLIED TO STUD FRAMING ®16"o.c. MAX. U.N.O. ON PLAN, 3. 5HEATHIN6 SHALL BE CONTINUOUS FULL HE16HT OF 2ND FLOOR WALL FROM BOT. OF RIM TO DOUBLE TOP PLATE. 4. ALL SHEAR HALLS SHALL HAVE DOUBLE TOP PLATES FASTENED TOGETHER w/ %"x0.131" NAILS 0 16"O.G. USE (8) %"0.131" NAILS m EA. LAP 5PLIGE. (TYP. U.N.0) 5. LATERAL ANALY515 ASSUMES ALL INTERIOR SHEAR WALLS AND EXTERIOR HALLS ARE GONTINUOU5 SHEATHED ABOVE AND BELOW OPENINGS. 6. SEE ARGHITEGTURAL DRAWIN65 FOR ADD'L WALL GON5TRUGTION REQUIREMENT5. 1. ALL EXTERIOR HALLS GON5IDERED FOR SHEAR WALL5 8. WHERE PANELS ARE APPLIED TO BOTH FAGE5 OF WALL, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS. ROOF FRAMIN6 • SEE ROOF TRU55 UPLIFT CONNECTOR 5GHEDULE FOR ALL ROOF TRUSS CONNECTORS. • ROOF 5HEATHING SHALL BE 1/16" MIN. 05B/PLYWOOD 5HEATHIN6 2446, EXP05URE I. FASTEN 5HEATHING TO ROOF MEMBERS W/ 2s/6"x0.113 RING SHANK (R5R5-01) NAILS (OR BETTER) 0 6" o.c. 0 PANEL ED6E5 $ IN FIELD. PROVIDE "H" STYLE CLIPS ALON6 UNSUPPORTED EDGES. FASTEN 5HEATHING TO GABLE END 4 DRAG TRUSSES w/ NAILS 0 3" O.G. • AT ALL AREAS WITHIN THE END ZONE D15TANCE FROM ROOF EDGES, RIDGE5, VALLEYS, & HIPS, PROVIDE BLOCKING ALONG PANEL EDGE5 4 FASTEN w/ 2)'2"x0.131" NAILS 0 4" O.G. AN END ZONE 15 DEFINED AS 10% OF THE BUILDIN65 LEAST HORIZ. DIMEN51ON (I.E.: 30' WIDE = 3' END ZONE). • ROOF SHEATHING FOR MAIN ROOF TRU55ES SHALL EXTEND CONTINUOUSLY UNDER ALL OVERFRAMIN(5. • TRU55 ALL VALLEY SETS, FASTEN EACH END TO TRU55 BELOW W/ U51P MTWI2 AND (2) 300.131" TOENAILS TO EACH TRU55 BETWEEN. • ALL METAL HANGERS SHALL BE SPECIFIED BY THE TRU55 MANUFACTURER, UNLE55 OTHERWI5E NOTED. • ROOF TRU55 SHOP DWGS, SHALL BE SUBMITTED TO ARCH d ENG. FOR REVIEW AND APPROVAL PRIOR TO FABRICATION OR DELIVERY. • SUPPORT PORCH 4 SHORT SPAN ROOF TRUSSES W/ 2x4 LEDGER FASTENED TO FRAMING P02) 3"x0.131" NAILS 0 Ib" O.G. UPLIPT CONNECTORS BEARING CONDITION ��.� CONNECTOR HO -1 51MP50N HTT-4 HOLD-DOWN (W/ 55TBI6 A.B) b HD -2 SIMPSON MSTGbb STRAP TIE (24" END LENGTH) (M5TGb(b83 ALTERNATE) (15, 51MP50N H2.5A 51NGLE ROOF TRU55 BEARING ON 5PAN HEADER WOOD STUD WALL/WOOD BEAM 2 2x8 5PF OR 5YP #2 H/ H4xb 3.5"x5.5" AFP IbE 5HORT > 15' 51MP50N HIOA ROOF GIRDER TRU55 BEARING ON ALL 51MP50N HT520 WOOD STUD WALVWOOD BEAM H4x10 35"x95" AFP I.6E SHORT 51NGLE ROOF TRU55 OR PORCH ALL 51MP50N HETAI6 BEAM BEARING ON GMU WALL (2)2x12 2 2x12 5PF OR 5YP #2 W/ ROOF 61RDER TRU55 OR FLU51­1 ALL (2) 51MP50N HETAIb BEAM BEARING ON GMU WALL SPAN HEADER ALL BEARING POINT5 OF EACH ROOF TRU55 5HALL BE CONNECTED WITH CONNECTOR A5 1_15TED ABOVE. LEGEND • ® INTERIOR BEARING WALL • _ _ _ BEARING WALL ABOVE • - • • - BEAM / HEADER • LOCATION AND EXTENT OF SHEAR WALL • I I EXTENT OF OVERFRAMIN6 U J INDICATES LOGATION OF REINFORCED GMU GORE 'l (5EE NOTE5) J L METAL HANGER INDICATES P05T ABOVE. PROVIDE SOLID 13LOGKIN6 UNDER P05T OR JAMB ABOVE. mmmmmmmffj HEAVER SUBSTITUTION SCHEDULE HOLD-DOWN 50HEDULE SYMBOL SPEGIFIGATION HO -1 51MP50N HTT-4 HOLD-DOWN (W/ 55TBI6 A.B) b HD -2 SIMPSON MSTGbb STRAP TIE (24" END LENGTH) (M5TGb(b83 ALTERNATE) 3.5"x5.5" AFP I.bE 5HORT LEGEND • ® INTERIOR BEARING WALL • _ _ _ BEARING WALL ABOVE • - • • - BEAM / HEADER • LOCATION AND EXTENT OF SHEAR WALL • I I EXTENT OF OVERFRAMIN6 U J INDICATES LOGATION OF REINFORCED GMU GORE 'l (5EE NOTE5) J L METAL HANGER INDICATES P05T ABOVE. PROVIDE SOLID 13LOGKIN6 UNDER P05T OR JAMB ABOVE. mmmmmmmffj HEAVER SUBSTITUTION SCHEDULE LABEL DESCRIPTION LABEL DE5GRIPTION (2)2x6 2 2x61 5PF OR 5YP #2 H1 H4X6 3.5"x5.5" AFP I.bE 5HORT 1/2" PLYWD FLITCH PLATE 5PAN HEADER (2)2x8 2 2x8 5PF OR 5YP #2 H/ H4xb 3.5"x5.5" AFP IbE 5HORT LL 1/2" PLYWD FLITGH PLATE S D I 5PAN HEADER (2)2xI0 2 2xI0 5PF OR 5YP #2 W/ H4x10 35"x95" AFP I.6E SHORT 1/2" PLYWD FLITCH PLATE 5PAN HEADER (2)2x12 2 2x12 5PF OR 5YP #2 W/ H4x10 3.5"x9.5" AFP IhE 5HORT date: I/2 PLYWD FLITCH PLATE SPAN HEADER 1. WHERE 5PF OR 5YP #2 BUILT-UP HEADERS ARE 5PEGIFIED ON THE PLANS, ANTHONY FOREST PRODUCTS (AFP) I.6E 5HORT5PAN HEADERS MAY BE 51,65TITUTED PER THE HEADER 5065TITUTION SCHEDULE ABOVE. 2. AFP IbE 5HORT5PAN HEADER5 HAVE THE FOLLOWING MINIMUM PROPERTIES: E = I,6Oop00 psi, Fb = 1,500 psi, Fv = 175si, Fc -perp = 650 psi. 3. AFP 1.6E 5HORT5PAN HEADER5 MAY NOT BE 5UB5TITUTED WHERE BUILT-UP LVL HEADER5 ARE 51FEGIFIED ON THE PLAN5. 4. REFER TO THE 5TANDARD HEADER NOTES WITHIN GENERAL FRAMING NOTE5 ON SHEET 50.0 FOR ADDITIONAL HEADER INFORMATION. THIS MODEL HAS SEEN DESIGNED IN AGGORDANGE WITH THE 6th EDITION (2011) FLORIDA BUILDING GODS (SECTION IbOq) LATERAL DE516N REQUIREMENTS AOR THE FOLLOWIN6 COMMUNITIES ONLY: A /-\ I, '? t -n I I t- \ /r-) WH15PERIN6 RID6E 5T. JAME5 GRO551 N6 5HEARWATER E5TATE5 WYNDHAM PRE5ERVE - BR 155ON E. ANY COMMUNITY NOT L 15TED HERE REQU I RE5 FORMAL EVALUATION $ APPROVAL FROM MULHERN 4 KULP 5TRUGTURAL EN61 NEERI N6. GENERAL STRUCTURAL NOTES • DE516N 15 BASED ON bth EDITION (2011) FLORIDA BUILDING CODE. • WOOD FRAME ENGINEERING 15 BASED ON NDS, "NATIONAL DE516N 5PEGIFIGATION FOR WOOD CONSTRUCTION" - LATEST EDITION. • DE516N LOADS: ROOF LIVE = 20 P5F DEAD = I P5F T.G., 10 P5F B.G. LOAD DURATION FACTOR = 1.25 FLOOR LIVE = 40 P5F (INGLUDIN6 5TAIR5) = 30 P5F ® SLEEPING AREAS = 50 P5F ® 6ARA6E DEAD = 10 P5F (20 P5F TOTAL ® TILE) WIND ULTIMATE WIND SPEED 4 EXP05URE A5 LISTED R15K GATE60RY 11 GENERAL FRAM I NO • EXTERIOR WOOD STUD BEARING WALL5 SHALL BE 2x4 5PF#2 OR 5YP#2 0 16" O.G., OR BETTER (TYP. U.N.O. ON PLANS). • INTERIOR WOOD STUD BEARING WALL5 SHALL BE 2x4 5PF OR 5YP '5TUD' GRADE LUMBER 0 I b" O.G., OR BETTER (TYP. U.N.O. ON PLANS). • ALL INTERIOR 5HEARWALL5 SHALL BE CONSTRUCTED WITH 2x 'STUD' GRADE MEMBERS SPACED 0 Ib" O.G. (MAX). • ALL NON-BEARING INTERIOR STUD HALLS SHALL BE CONSTRUCTED WITH 2x '5TUD' GRADE MEMBERS SPAGED 0 24" O.G. (MAX). SINGLE TOP PLATES ALLOWED PER Rb02.2.2.1, • ALL HEADERS SHALL BE SUPPORTED BY (1)2x JACK STUD 4 (1)2x KING 5TUD, MINIMUM. - THE NUMBER OF STUDS SPECIFIED AT A SUPPORT INDICATES THE NUMBER OF JACK STUDS REQUIRED, U.N.O., • ALL HEADERS, BEAMS d OTHER 5TRUGTURAL MEMBERS SHALL BE 5PRUGE-PINE-FIR #2 (5PF) OR SOUTHERN PINE #2 (5YP) LUMBER, OR BETTER (KILN -DRIED). • FACE NAIL MULTI -PLY 2x BEAMS # HEADERS W/ 3 -ROWS OF 3"x0.131" NAILS 0 12" O.G. 5TACGGERED. APPLY NAILING FROM BOTH FAGE5 0 3 -PLY OR MORE CONDITIONS. UTILIZE 2 ROW5 OF NAILS FOR 2x6 8 2x8 MEMBERS. • FACE NAIL BUILT UP 2x POSTS W/ 3"4.131" NAILS 0 16" O.G. 5TA66ERED, APPLY NAILING FROM BOTH FACES 0 3 -PLY OR MORE CONDITIONS. • REFER TO CONNECTION SPECIFICATIONS TABLE FOR ALL GONNEGTIONS (TYP. U.N.O. ON PLANS). • SHEATH ALL WOOD FRAMED EXTERIOR HALLS W 1/16" 05B FASTENED w/ ANO.131" NAILS ® 6" O.G. 0 ED6E5 4 12" O.G. GENTER FIELD. PROVIDE HORIZONTAL 2x BLOGKIN6 AT ALL UNSUPPORTED PANEL ED6E5. TYPICAL U.N.O. ON THE PLANS. • PROVIDE SOLID BLOGKIN6 IN FLOOR 5Y5TEM UNDER ALL POSTS CONTINUOUS TO FOUNDATION/BEARING. • ENGINEERED LUMBER TO MEET OR EXCEED THE FOLLOWING: • LSL - Fb=2325 psi; Fv=310 psi; E=1.55x10" 6 psi • LVL - Fb=2600 psi; Fv=285 psi; E=2,Ox10�(7 psi • FOR 2 $ 3 PLY BEAMS OF EQUAL WIDTH, FA5TEN PLIES TOGETHER WITH 3 ROWS OF 304.131" NAILS 0 6" OIG OR 2 ROW5Y4"x3Y2 51MP50N 5D5 5GREW5 (OR 3)/2" TRU55LOK 5GREW5) 0 Ib" O/G. USE A MINIMUM OF 3 ROWS FOR BEAM DEPTHS OF 14" OR GREATER. APPLY FASTENINe AT BOTH FACES FOR 3 -PLY CONDITION. LOCATE TOP t BOTTOM NAILS/SGREWS 2" FROM EDGE. SOLID 3Y2" OR 5Y4" BEAM5 ARE ACCEPTABLE. USE 2 ROWS OF NAILS FOR 2xb 4 2x8 MEMBERS. • FOR 4 PLY BEAMS OF EQUAL WIDTH, FASTEN PLIES TOGETHER WITH 3 ROW5 OF Y4"xb" SIMPSON 5D5 56REW5 (OR b 1/4" TRU55LOK 5GREW5) 0 Ib" 0/0. USE A MINIMUM OF 4 ROWS FOR BEAM DEPTHS OF 14" OR GREATER. APPLY FA5TENIN6 AT BOTH FACES (ONE SIDE ONLY FOR TRU55LOK 50REW5). LOCATE TOP AND BOTTOM 5GREW5 2" FROM E06E. A SOLID 7" BEAM 15 ACCEPTABLE. • ALL EXTERIOR 4x4 WOOD P05T5 SHALL HAVE 51MP50N PG4Z/EP04Z CAP t ABU44Z BASE, U.N.O. • ALL INTERIOR WALL STUDS IN CONTACT W GMU WALLS SHALL BE PRESERVATIVE TREATED AND FASTENED W/Y4" DIA. X 4" LONG TAP( ON5 0 24" O.G. Seal. 1/31/2018 No 7 624 " oIr °® T! O F y �� Q copyright: MULHERN & KULP Structural Engineering, Inc, a ra E Q W U, _ z II!, J 4� CL �Cq CN sheet: S000 W IF H d W project number z z 181-17014 LL prelim mgr S D I drawn by G DV issue date: 07-06-17 REVISIONS: o date: initial: 11-09-17 MK LQ 12-11-17 MK sheet: S000 W H d z z LL aW0 LIJ o LQ N O sheet: S000 28'-0" PORCH SLAB: 3 1/2" GONG. SLAB ON GRADE iv I (2500 PSI MIN) w/ bxb-01.4x01.4 0 >v MESH OR FIBER MESH ON 15% COMPACTED FILL OR VIRGIN 501L o I _ I 1 5DI.0 I 501.0 yoot� D2. I6'-0" pr 2'-4" 20'-8" 28'-0" 5LA5 FOUNI;A71ON PLAN 22x34 SCALE: 1/4"=1'-0" 110 SCALE: -011 ELEVS. 5, T, $ U 3 TERMITE PROTECTION - 5ENTRIGON (AS GH05EN BY BUILDER) I. TERMITE PROTECTION SHALL BE IN ACCORDANCE WITH THE FBG R318 AND ALL RELATED 5UBGATE60RIE5. 2. PROTECTIVE SLEEVES AROUND PIPING PENETRATING GONGRETE SLAB -ON -GRADE F=LOORS SHALL NOT BE OF GELLUL05E GONTAININ6 MATERIALS. IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE MAXIMUM WALL THIGKNE55 OF 0.010 INCH AND BE SEALED WITHIN THE SLAB U51% A NON-GORRO5IVE GLAMPIN6 DEVICE TO ELIMINATE THE ANNULAR SPACE BETWEEN THE PIPE AND THE SLEEVE. NO TERMITIGIDE5 SHALL BE APPLIED IN51DE THE SLEEVE. 3. CONDENSATE LINE, IRRIGATION/SPRINKLER 5Y5TEM RISERS FOR SPRAY HEADS, AND ROOF DOWNSPOUTS SHALL 015GHAR6E AT LEAST I FOOT (305mm) AWAY FROM THE STRUCTURE SIDENALL, WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. 6UTTER5 WITH DOHN5PUT5 ARE REQUIRED ON ALL BUILDIN65 WITH EAVES OF LE55 THAN 6 INGHE5 (152mm) HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF HOLO -DOWN SCHEDULE 5YM130L SPECIFICATION 1-10-1 SIMP50N HTT-4 HOLD-DOWN (w/ 55TBIb A,B.) 1-10-2 SIMPSON M5TGbb STRAP TIE (24" END LENGTH) (M5TGbbD3 ALTERNATE) TA F � � O 5"REGESS PER 0 Q copyright: MULHERN & KULP MANUF. INSTRUCTIONS I Structural Engineering, Inc. CONCRETE SLAB: J 3 1/2" GONG. SLAB ON GRADE 5� 5 rno.. a (2500 P51 MIN) w/ bxb-HI.4xHl.4 c a`i ca Z MESH OR FIBER MESH OVER b W 4- MIL. POLY ON g5% COMPACTED FILL OR VIRCGIN 501L w � 6 8 L� Ld n. N SEE BLOCK PLAN FOR I VERTICAL BAR LOCATIONS 181-17014 project mgr: I i 501.0 G D V 501.0 issuedate: 07-06-17 i REVISIONS: rn m initial: I I MK 12-11-17 MK r -- I I 14'-10" 13'-2" I 40 I I 4 20"x20"x20" GONG. o I I 501.0 FTG. o HD HO -1 5 Ig' -101/2„ SDI.o8'-11/2" 8 PROVIDE Y4" DIA. x 5" LONG 1501.0 �� II TAPGON5 o Ib O.G. N I o REAR OF GARAGE L — - — -� 2 6ARAGE SLAB: 3 112" GONG. 5LA13 ON GRADE _ (2500 PSI MIN) W bxb-NI.4xNl.4 - o I o MESH OR FIBER MESH OVER 6 N I N MIL. POLY ON 95% COMPACTED I 501.0 J ---I FILL OR VIRGIN 501L F- I L _I I N I L21 m --.l,,x8, PAD FTG. I o 6 501.0 2 L..-- ----------- _._) 501.0 yoot� D2. I6'-0" pr 2'-4" 20'-8" 28'-0" 5LA5 FOUNI;A71ON PLAN 22x34 SCALE: 1/4"=1'-0" 110 SCALE: -011 ELEVS. 5, T, $ U 3 TERMITE PROTECTION - 5ENTRIGON (AS GH05EN BY BUILDER) I. TERMITE PROTECTION SHALL BE IN ACCORDANCE WITH THE FBG R318 AND ALL RELATED 5UBGATE60RIE5. 2. PROTECTIVE SLEEVES AROUND PIPING PENETRATING GONGRETE SLAB -ON -GRADE F=LOORS SHALL NOT BE OF GELLUL05E GONTAININ6 MATERIALS. IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE MAXIMUM WALL THIGKNE55 OF 0.010 INCH AND BE SEALED WITHIN THE SLAB U51% A NON-GORRO5IVE GLAMPIN6 DEVICE TO ELIMINATE THE ANNULAR SPACE BETWEEN THE PIPE AND THE SLEEVE. NO TERMITIGIDE5 SHALL BE APPLIED IN51DE THE SLEEVE. 3. CONDENSATE LINE, IRRIGATION/SPRINKLER 5Y5TEM RISERS FOR SPRAY HEADS, AND ROOF DOWNSPOUTS SHALL 015GHAR6E AT LEAST I FOOT (305mm) AWAY FROM THE STRUCTURE SIDENALL, WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. 6UTTER5 WITH DOHN5PUT5 ARE REQUIRED ON ALL BUILDIN65 WITH EAVES OF LE55 THAN 6 INGHE5 (152mm) HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF PORCH SLAB: 3 1/2 " GONG. SLAB ON GRADE (2500 PSI MIN) W bxb-NI.4xNl.4 MESH OR FIBER MESH ON 15% COMPACTED FILL OR VIRGIN 501L GENERAL 5TRUGTURAL NOTE5 FOUNPATION • DE516N 15 BASED ON bth EDITION (2011) FLORIDA BUILDING CODE. • FOOTING DE516N - THESE FOOTINC75 HAVE BEEN ENGINEERED FOR A MINIMUM ALLOWABLE 501L BEARING GAPAGITY OF 1,500 P5F. THESE FOUNDATION DE516N5 ARE AL50 ADEQUATE FOR ALLOWABLE 501L BEARING CAPACITIES GREATER THAN THE 1500 P5F MIN. REQUIRED. (I.E. IF 2000 P5F 501L 15 PRESENT, THESE FOUNDATION DE516N5 ARE STILL ADEQUATE. • ALL LUMBER EXPOSED TO WEATHER OR IN GONTACT H/ GONGRETE OR MASONRY FOUNDATION SHALL BE PRESERVATIVE TREATED SOUTHERN PINE #2. • BUILDER TO VERIFY GORRO51ON-RESISTANCE COMPATIBILITY OF HARDWARE 4 FA5TENER5 IN CONTACT W PRESERVATIVE -TREATED WOOD. CONTACT LUMBER 4 HARDWARE 5UPPLIER5 TO COORD. • GONGRETE DESIGN BASED ON AGI 318. GONGRETE SHALL ATTAIN THE FOLLOWING MINIMUM COMPRESSIVE 5TREN6TH5 IN 28 DAYS, U.N.O.: Pc = 2,500 p51:....... FOOTINC75 2,500 psi:....... 5LA135 ON GRADE (INTERIOR it EXTERIOR) fy = 60,000 psi ...... REBAR • ALL CONCRETE EXP05ED TO THE HEATHER SHALL NOT HAVE LE55 THAN 5% OR MORE THAN 1% AIR ENTRAINMENT. • ALL FOOTIN65 SHALL BEAR AT LEAST 12 BELOW FIN15H GRADE. • FOOTINC75 AND 5LAB5 ON GRADE SHALL BEAR ON VIR61N SOIL OR 015% GOMPAGTED FILL. • PROVIDE GONTROL JOINTS AT ALL INSIDE CORNERS OF 5LA13 ED6E5, AND OTHER LOCATIONS WHERE SLAB CRAGK5 ARE LIKELY TO DEVELOP. (20'-0" O.G) • MINIMUM LAP SPLICES ON ALL REINFORCEMENT SHALL BE 46 BAR DIA. • HOOKS SHALL BE PROVIDED AT DISCONTINUOUS END OF REINF. • GROUT 5HAL.L BE ASTM 6476 F'c=3000 P51 w/ MAX 3/a" AGGREGATE • CONCRETE MA50NRY UNITS SHALL BE A5TM Gqo HITH A MINIMUM COMPRESSIVE 5TRENOTH OF Ig00 P51 (F'M = 1500 P51). ALL MORTAR SHALL BE A5TM G210, TYPE 5. GMU DE516N BASED ON AGI 530/530.1 • �REINFORGED GMU GORES (AS INDICATED ON PLAN) SHALL BE REINFORCED W (1) #5 BAR VERTICAL. BAR SHALL EXTEND INTO BOND BEAM AT TOP WALL AND SHALL AL16N WITH FOOTING DOWEL DELON. PROVIDE MIN 30" LAP 5PLIGE WITH FOOTING DOWEL. • GROUT 50LID ALL REINFORCED GMU CELLS AND BOND BEAMS • ALL BOND BEAMS ARE TO BE CONTINUOUS FULL LENGTH OF HALL ` PROVIDE (1) #5 BAR GROUTED 50LID ON EACH 51DE OF ALL MASONRY OPENIN65 AND AT ALL NALL CORNERS. • VERTICAL REINFORGEMENT 5HALL BE HELD IN PLACE AT THE TOP AND BOTTOM, SHALL BE LOCATED IN THE CENTER OF THE MA50NRY GELL, AND SHALL BE LOCATED AT A MAXIMUM OF 6-0" O.G. IN EXTERIOR WALLS. (A5 SHOWN ON PLANS) • ROU6H OPENINC75 ARE GALLED OUT ON PLAN - BUILDERS TO VERIFY. Seal. 1/3 1 /2018 t il;' HOLO -DOWN SCHEDULE 5YM130L SPECIFICATION 1-10-1 SIMP50N HTT-4 HOLD-DOWN (w/ 55TBIb A,B.) 1-10-2 SIMPSON M5TGbb STRAP TIE (24" END LENGTH) (M5TGbbD3 ALTERNATE) TA F PORCH SLAB: 3 1/2 " GONG. SLAB ON GRADE (2500 PSI MIN) W bxb-NI.4xNl.4 MESH OR FIBER MESH ON 15% COMPACTED FILL OR VIRGIN 501L GENERAL 5TRUGTURAL NOTE5 FOUNPATION • DE516N 15 BASED ON bth EDITION (2011) FLORIDA BUILDING CODE. • FOOTING DE516N - THESE FOOTINC75 HAVE BEEN ENGINEERED FOR A MINIMUM ALLOWABLE 501L BEARING GAPAGITY OF 1,500 P5F. THESE FOUNDATION DE516N5 ARE AL50 ADEQUATE FOR ALLOWABLE 501L BEARING CAPACITIES GREATER THAN THE 1500 P5F MIN. REQUIRED. (I.E. IF 2000 P5F 501L 15 PRESENT, THESE FOUNDATION DE516N5 ARE STILL ADEQUATE. • ALL LUMBER EXPOSED TO WEATHER OR IN GONTACT H/ GONGRETE OR MASONRY FOUNDATION SHALL BE PRESERVATIVE TREATED SOUTHERN PINE #2. • BUILDER TO VERIFY GORRO51ON-RESISTANCE COMPATIBILITY OF HARDWARE 4 FA5TENER5 IN CONTACT W PRESERVATIVE -TREATED WOOD. CONTACT LUMBER 4 HARDWARE 5UPPLIER5 TO COORD. • GONGRETE DESIGN BASED ON AGI 318. GONGRETE SHALL ATTAIN THE FOLLOWING MINIMUM COMPRESSIVE 5TREN6TH5 IN 28 DAYS, U.N.O.: Pc = 2,500 p51:....... FOOTINC75 2,500 psi:....... 5LA135 ON GRADE (INTERIOR it EXTERIOR) fy = 60,000 psi ...... REBAR • ALL CONCRETE EXP05ED TO THE HEATHER SHALL NOT HAVE LE55 THAN 5% OR MORE THAN 1% AIR ENTRAINMENT. • ALL FOOTIN65 SHALL BEAR AT LEAST 12 BELOW FIN15H GRADE. • FOOTINC75 AND 5LAB5 ON GRADE SHALL BEAR ON VIR61N SOIL OR 015% GOMPAGTED FILL. • PROVIDE GONTROL JOINTS AT ALL INSIDE CORNERS OF 5LA13 ED6E5, AND OTHER LOCATIONS WHERE SLAB CRAGK5 ARE LIKELY TO DEVELOP. (20'-0" O.G) • MINIMUM LAP SPLICES ON ALL REINFORCEMENT SHALL BE 46 BAR DIA. • HOOKS SHALL BE PROVIDED AT DISCONTINUOUS END OF REINF. • GROUT 5HAL.L BE ASTM 6476 F'c=3000 P51 w/ MAX 3/a" AGGREGATE • CONCRETE MA50NRY UNITS SHALL BE A5TM Gqo HITH A MINIMUM COMPRESSIVE 5TRENOTH OF Ig00 P51 (F'M = 1500 P51). ALL MORTAR SHALL BE A5TM G210, TYPE 5. GMU DE516N BASED ON AGI 530/530.1 • �REINFORGED GMU GORES (AS INDICATED ON PLAN) SHALL BE REINFORCED W (1) #5 BAR VERTICAL. BAR SHALL EXTEND INTO BOND BEAM AT TOP WALL AND SHALL AL16N WITH FOOTING DOWEL DELON. PROVIDE MIN 30" LAP 5PLIGE WITH FOOTING DOWEL. • GROUT 50LID ALL REINFORCED GMU CELLS AND BOND BEAMS • ALL BOND BEAMS ARE TO BE CONTINUOUS FULL LENGTH OF HALL ` PROVIDE (1) #5 BAR GROUTED 50LID ON EACH 51DE OF ALL MASONRY OPENIN65 AND AT ALL NALL CORNERS. • VERTICAL REINFORGEMENT 5HALL BE HELD IN PLACE AT THE TOP AND BOTTOM, SHALL BE LOCATED IN THE CENTER OF THE MA50NRY GELL, AND SHALL BE LOCATED AT A MAXIMUM OF 6-0" O.G. IN EXTERIOR WALLS. (A5 SHOWN ON PLANS) • ROU6H OPENINC75 ARE GALLED OUT ON PLAN - BUILDERS TO VERIFY. Seal. 1/3 1 /2018 t il;' U) Z a z J z� LL r1 `l n No 77324 LLJ TA F � � O 0 Q copyright: MULHERN & KULP �- Structural Engineering, Inc. J m 5� 5 rno.. a c a`i ca Z W 4- J 4-J c w � 6 8 L� Ld n. W project number. 181-17014 project mgr: S D I drawn by: G D V issuedate: 07-06-17 REVISIONS: date: initial: 11-09-17 MK 12-11-17 MK U) Z a z J z� LL r1 `l n REFER TO 5-0.0 FOR TYPICAL sheet: LEFT HAND STRUCTURAL NOTES $ SCHEDULES S 1 •O LLJ Q � � O 0 �- N N O REFER TO 5-0.0 FOR TYPICAL sheet: LEFT HAND STRUCTURAL NOTES $ SCHEDULES S 1 •O "t 0 1 5EE 50HEOULE AND 5PECIFICATION5 FOR ADD'L INFO 6ROUT PRECAST LINTEL W 6ROUT BOTTOM REIW. PRECAST LINTEL W EMBEDDED REINF. � I I EMBEDDED REINF. N MB -2 M13-1 o - — TOP REINF, — TOP REINR z 28'-0" 241-4" 17'-8" 10'-4" 6'-£i" 3'-0° 5TART M13-1 MB -I CONT. MB -3 J D2. 2'-0" START BLOCK PLAN 22x34 SCALE: 14"=1'-0" 11x1'1 SCALE: I/S'=1'-0" ELEV5. 5, T, $ U F F 'd- d- d- 0 d - Io MASONRY LINTEL ASSEMBLIES 5EE 50HEOULE AND 5PECIFICATION5 FOR ADD'L INFO 6ROUT PRECAST LINTEL W 6ROUT BOTTOM REIW. PRECAST LINTEL W EMBEDDED REINF. � I I EMBEDDED REINF. MB -1 MB -2 M13-1 8F8-OB/OT — TOP REINF, — TOP REINR MB-2 VERTICAL ----- SHEAR TIES m GROUT o BOTTOM REINF. - BOTTOM REINF. P ,� ` 'PRECAST LINTEL W EMBEDDED REINF. PRECAST LINTEL W I I EMBEDDED REINF. AND LOTT'S CONCRETE. � � 2. 5HORE FILLED LINTELS A5 REQURIED. THI5 A55EMBLY REQ. MB -3/ MB -3A SsT MB-4/MB-4A TIC� MB-#A LINTEL5o LINTEL517E51GNATED WITH AN MB -36/46 5HALL BE 6ON57RUCTED THE 5AME A5 MD -3/4 EXCEPT THE DEPTH 5HALL BE MODIFIED FROM 1'-4" TO 1'-2' BY FIELD CUTTING THE TOP OF THE PRECAST LINTEL DONN 2'. ALL OTHER SPECIFICATIONS SHALL REMAIN THE SAME. BOND BEAM REINF %HALL RUN CONT THRU TOP LINTEL C ASE. MASONRY LINTEL DETAILS REINFORCEMENT MARK DE-516RATION TOP BOTTOM SHEAR REINFORCEMENT M13-1 8F8-OB/OT ----- ---- MB-2 8F8-I5/0T ----- (1) #5 M13-3 81=I6-113/17 (1) #5 (1) #5 MB -4 81`16-213/11T(U #5 (2) #5 #3 VERTICAL TIES a 4"o.c. vi/ 180 DE6REE HOOK U13 APPROVED LINTEL MANUFAGTURER5 ARE: GA5T-CRETE, QUALITY PRECAST GO., AND LOTT'S CONCRETE. NOTES; 1. ALL LINTELS W SPANS GREATER THAN 14'-0" 5HALL BE PRE5TRE55ED. 2. 5HORE FILLED LINTELS A5 REQURIED. 3. ALL LINTELS SHALL HAVE 4" MINIMUM BEARING U.N.O. 4. DO NOT GUT OR MODIFY PRE5TRE55ED LINTEL5. 5. ALL REINFORCEMENT 5HALL BE GRADE 60, fy=60 W 6. ALL LINTELS SPECIFIED ON PLAN ARE MINIMUM 51ZE REQUIRED BY DE516N. TERMITE PROTECTION - 5ENTRIGON (A5 CHOSEN BY BUILDER) I. TERMITE PROTECTION SHALL BE IN ACCORDANCE WITH THE FBG R318 AND ALL RELATED 5UBGATE60RIE5. 2. PROTECTIVE 5LEEVE5 AROUND PIPING PENETRATING CONCRETE 5LAB-ON-GRADE FLOORS SHALL NOT BE OF GELLUL05E GONTAININ6 MATERIALS. IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE MAXIMUM WALL THICKNESS OF 0.010 INCH AND BE SEALED WITHIN THE SLAB U51146 A NON-GORRO51VE GLAMPIN6 DEVICE TO ELIMINATE THE ANNULAR SPACE BETWEEN THE PIPE AND THE SLEEVE. NO TERMITIGIDE5 SHALL BE APPLIED INSIDE THE SLEEVE. 3. CONDENSATE LINE, IRRIGATIOW5PRINKLER SYSTEM RISERS, FOR SPRAY HEADS, AND ROOF DOWN5POUT5 SHALL 1?15GHAR6E AT LEAST I FOOT (305mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR 5PLA5H BLOCKS. 6UTTER5 WITH DOWN5PUT5 ARE REQUIRED ON ALL BUILDIN65 WITH EAVE5 OF LE55 THAN 6 INGHE5 (152mm) HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF GENERAL STRUCTURAL NOTES FOUNRATION • DESIGN 15 BA5ED ON 6th EDITION (2011) FLORIDA BUILDING GORE. • FOOTING DESIGN - THE5E FOOTIN65 HAVE BEEN ENGINEERED FOR A MINIMUM ALLOWABLE 501L BEARING CAPACITY OF 1,500 P5F. THE5E FOUNDATION DE516N5 ARE AL50 ADEQUATE FOR ALLOWABLE 501L BEARING GAPAGITIE5 GREATER THAN THE 1500 P5F MIN. REQUIRED. (I.E. IF 2000 P5F 501L 15 PRE5ENT, THE5E FOUNDATION DE516N5 ARE STILL ADEQUATE. • ALL LUMBER EXP05ED TO WEATHER OR IN GONTAGT W/ CONCRETE OR MA50NRY FOUNDATION SHALL BE PRESERVATIVE TREATED SOUTHERN PINE #2. • BUILDER TO VERIFY GORRO51ON--RES15TANGE GOMPAT1131LITY OF HARDWARE 4 FASTENERS IN CONTACT W PRESERVATIVE -TREATED WOOD. CONTACT LUMBER 4 HARDWARE 5UPPLIER5 TO GOORD. • CONCRETE DESIGN BA5ED ON AGI 316. CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM COMPRE551VE 5TREN6TH5 IN 28 DAY5, U.N.O.. Pc = 2,500 p5l:....... FOOTIN65 2,500 p5l:....... SLABS ON GRADE (INTERIOR t EXTERIOR) fy 60,000 p5l ...... REBAR • ALL CONCRETE EXP05ED TO THE WEATHER SHALL NOT HAVE LE55 THAN 5% OR MORE THAN 1% AIR ENTRAINMENT. • ALL FOOTIN65 5HALL BEAR AT LEAST 12" BELOW FIN15H GRADE. • FOOTIN65 AND 5LA65 ON GRADE SHALL BEAR ON VIRGIN 501L OR 95% GOMPAGTED FILL • PROVIDE CONTROL JOINTS AT ALL IN51DE GORNER5 of SLAB ED6E5, AND OTHER LOGATION5 WHERE SLAB CRACKS ARE LIKELY TO DEVELOP. (20'-0" O.G) • MINIMUM LAP 5PLIGE5 ON ALL REINFORCEMENT SHALL BE 48 BAR DIA, • HOOKS SHALL BE PROVIDED AT D15GONTIN0005 END OF REINF. • GROUT SHALL BE ASTM 6476 F'c=3000 PSI N/ MAX 3/g" AGGREGATE • CONCRETE MA50NRY UNITS SHALL BE ASTM Gqo WITH A MINIMUM GOMPRE551VE 5TREN6TH OF I a00 P51 (F'M = 1500 P51). ALL MORTAR SHALL BE A5TM G210, TYPE 5. GMU DE516N BASED ON AGI 530/530.1 • REINFORCED GMU GORES (A5 INDICATED ON PLAN) SHALL BE REINFORCED N/ (1) #5 BAR VERTICAL. BAR SHALL EXTEND INTO BOND BEAM AT TOP WALL AND 5HALL ALIGN WITH FOOTING DOWEL BELOW. PROVIDE MIN 30" LAP SPLICE WITH FOOTING DOWEL. • GROUT 50LID ALL REINFORCED GMU GELL5 AND BOND BEAMS • ALL BOND BEAMS ARE TO BE CONTINUOUS FULL LENGTH OF WALL • PROVIDE (1) #5 BAR 6ROUTED 50LID ON EACH 51DE OF ALL MA50NRY OPENIN65 AND AT ALL WALL GORNER5. • VERTICAL REINFORCEMENT 5HALL BE HELD IN PLACE AT THE TOP AND BOTTOM, SHALL BE LOCATED IN THE CENTER OF THE MA50NRY GELL, AND SHALL BE LOCATED AT A MAXIMUM OF 8'-0" O.G. IN EXTERIOR WALLS. (A5 5HOWN ON PLAN5) • ROUGH OPENINGS ARE GALLED OUT ON PLAN - BUILDERS TO VERIFY. REFER TO 5-0.0 FOR TYPICAL STRUCTURAL NOTES ff SCHEDULES Z J Z � U. J a CL � o 00 z m N O sheet: LEFT HAND e10 n seal, 1/31/2015 n m�. a°« No 77824 V. M,..$ Np f3 % © copyright : MUk&WLP Structural Engineering, Inc, W � � a rn c a`i co ` 7 ul) V N rn _ -; 4D J Cq r N y L W project number 181-17014 project mgr, S D I drawn by: G D V Issuedate, 07-06-17 REVISIONS: date: initial: 11-09-17 MK 12-11-17 MK REFER TO 5-0.0 FOR TYPICAL STRUCTURAL NOTES ff SCHEDULES Z J Z � U. J a CL � o 00 z m N O sheet: LEFT HAND e10 n "t Nt 11—011 11-011 PRIOR RI . IOI RVL�T1,_ Ol..LI-N1 `5IVT1AI ILLING LO-LW..� _— v' L �— _ ROOF TRU55ES ROOD FRAMING PLAN 22x34 SCALE: 14"=I'-0" ELEVATION U I1x11SCALE: I/8(=1' -O" Seal: 1/31/2018 N10 77824 p © cop RN & KULP Structural Engineering, Inc. a� Q a z� �3 W ` N Zy. Jco - U) Cn �Q M&K project number: 181-17014 project mgr: S D I drawn by: C D V issuedate: 07-06-17 REVISIONS: date: initial: 11-09-17 MK 12-11-17 MK REFER TO 5-0.0 FOR TYPICAL STRUCTURAL NOTES 8 SCHEDULES ■ sheet: LEFT HAND 54.2 Z 0.4 z LL �W Ld LL 2 LL0o 00 z X N O sheet: LEFT HAND 54.2 8.. CMU BLOCK 8" CMU BLOCK R4.1 FI -FOIL OR (1) #5 FROM FT6. TO (U #5 FROM FT6. TO EQUAL OVER 3/4" BOND BEAM. SPLICE A. I" STRIPS TO BE MIN. 30" BOND BEAM. SPLICE GROUT CELL SOLID TO BE MIN. 30" ". 3,v2" GONG. SLAB w/ GROUT CELL SOLID `�: WWF OR FIBERMESH '' z REINF. OVER 6 MIL. VAPOR BARRIER d ' MATCH CMU LEDGE u x PER I/SOLO ° y 44. Q� z (z a III I I-111_1 I—I4 ° 4__—_— GRADE .. II_I 11=111=III-1 I �' - GRADE _ I_I I I—III—III ;I o I I I_I 1 5111 =III a4. II—III_III—III I' ' III—III—III—III ' . '° ' �—III—III—I I I l N oIII=111=1 LI o z —� III—III—III—I I I—III—III—_I I III—III—III d III_III—III- ;III—III III " 111 —111-1 1 =I I I_I I I—III11=TTI M I I—III- �—III=III ° _I I f I I I 1 11 1—II=III1 ' I Tf—I1I-111 _—III-1 11I-II I 11 _I e CLEAN lI —IL'I MONOLITHIC CLEAN FL FODAON WCOMPACTED MONOLITHIC 0"�0n FOUNDATION N 15% STANDARD (2) #5 HORIZ. 0 q5% STANDARD (2) #5 HORIZ. DEN5ITY MIN. CONT. ON CHAIRS DENSITY MIN. 0' MIN. COVER) CONT. ON CHAIRS WHERE 2ND STORY WHERE 2ND STORY (3" MIN. COVER) OCCURS FTG. SHALL BE OCCURS FTG. SHALL BE 1'-4" WIDE W (2) #5 BARS 1'-4' WIDE W (2) #5 BARS FOOTING 5ECT101W/ BLOCK PETAIL G, RAGE CURB DETAIL ;:,'.:;•;;;;;;;;;;;;, y GARAGE ' ; TOP YIEW NON -LOAD BRO. WALL ®CORNER F ---GARAGE WALL GA RA&E INTERIOR IY b 3 Y2" GONG. SLAB m4't ° ° . e '�:.• a a' a �d e. a. 4 11=1--1 _ I _—II1=1 I I—III_IT_I =III= I b III=III=III e. .. � °. a � � ���.. ' • I — 1 I I 1 11_—I= f.—I I I, I I I 1=1 III—III 111= 11=1 I L�i I- I - I' —1 I _III , I 11-1 I I=1 I I_ =1 I I—III—III—I I I=1 11=1 I I—I 11=11I' 20"x8" THICKENED -1 11=1 11=1 11=111=F=I 11=1 I I; EDGE w/ (2)#5 CONT. —I I T1 M=1I1=1 I I—II1=1 I I- O #5 CONT. W/ 1Il11=III=1 3' MIN. COVER OFSET FOOTING NONBEA�RI NG PETAL I L(THZKENEP PGE ® 6ARA 6E POOR DETAIL i71 6 90till M SLOPE 6. SPECS 3/4" RECESS o 5LIDIN6 a 6LA55 DR. 4 ! a • 8" CMU BLOCK SILL FORMED ON SITE a (1) #5 FROM FTG. TO EXP JOINT ° BOND BEAM. SPLICE TO BE MIN. 25" 6ROUT CELL 50LID SLOPE — SILL FORMED ON SITE 3 A CONC. SLAB — (2500 P5.1) W/ 6x6 - LU I 10/10 N.W.M. AND 6 MIL m w I VAPOR BARRIER GRADE �I 1 n . 4 14 4 R4.1 FI -FOIL OR EQUAL OVER 3/4" FURR STRIPS 3Y2"GONG. SLAB W/ WWF OR FIBERMESH REINF. OVER b MIL. VAPOR BARRIER • � d, �` � �� � � d =111=1T=1T=i� 1, ' � III—III—III—� I 1 ��III II—III- "47 77 ' III 1—TI EXP JOINT r ' .°d ' SP 5 - I _ A/c, CHASE PVC SLEEVE To BE —III,;�III=III—III TWICE THE DIAMETER OF PROTECTED PIPE q EXTERI 0R 0UT5W1 NG 1 561:1POURED 51 LL5 PET, I L I 0 GH,45 PETAL I L sca.e� errs sea[ 1/31/2015 Nio 77824 INTERIOR . Y2" GYP. BD. EA. SIDE Y2" 6YP. BD. EA. SIDE a "w OF 2x'5 0 16" O.G. OF 2x4'5 m Ib" O.G. I .. lA F • .A 5TUD PLATE TIES q /� C FASTEN N/Y4"x5" LONG TAPGONS" �4®°% 5TUD TOP 4 BOT. (IF GAIR,hGE 0 2'-b" O.C. AND 12 MAX FROM ��� ' • ° • �®�� NOTED ON PLANS) FASTEN N/Y4"x5" LONG TAPGON5 :211411 END OF WALL NNLE55 NOTED o 2'-&" O.G. AND 12 MAX FROM „ OTHERN15E ON PLANS) END OF WALL ONLE55 NOTED � 112 ©copyright : MULHERN & KULP PT. BOT. PLT. OTHERN15F ON PLANS) 5TUD PLATE TIES ® STUD Structural Engineering, Inc, } PT BOT. PLT. I TOP 4 BOT. OF NOTED ON PLANS) Q.. °'. a ea.•' a'. .•° C I —III—III—III—III ,..d. :. , • �-111_111_111 ,1 I = ° °•I •; • ' as a� 5� II_I I I—III—III d • 1. <' : •' • � ' < d 'Q —III=1 I f=1 I I— =1 11=1 11=1 I I— 1=1 11=1 11 � ''=ITI=1 I I—III III—I i I III -TTI —T=1 =1 11-1 I hI 11= l (D 8.. 8.. (2l #5 HORIZ. (� CONT. ON CHAIRS #5 HORIZ. ID" I 10" Z a 63" MIN. COVER) CONT. ON CHAIRS +, _Q 0" MIN. COVER) WHERE 2ND STORY � OCCURS FTG. SHALL BE W + y I'-8" WIDE W (3) #5 BARS U) S' E UPLIFT CONNECTORS SUCH AS STUD PLATE TIES, HURRICANE CLIPS, ETC. ARE NOT UPLIFT CONNECTORS SUCH AS STUD PLATE TIES, HURRICANE CLIPS, ETC. ARE NOT REQUIRED ON WALLS NOT EXP05ED TO UPLIFT FORGES (REFER TO PLAN5). PROVIDE REQUIRED ON WALLS NOT EXPOSED TO UPLIFT FORGES (REFER TO PLANS). PROVIDE J c ANCHORS AT BEARING WALLS PER ABOVE, UNLESS NOTED OTHERWI5E ON PLANS ANCHORS AT BEARING WALL5 PER ABOVE, MLE55 NOTED OTHERWI5E ON PLANS m INT. BEARING INALL FOOTING DETAIL 4 OFFSET POOTI NG BEARING PETAI L 3 scAt.� N'ra W^At tars IV W project number. 181-17014 8" CMU BLOCK BEYOND p i r S D I R4.1 FI -FOIL OR roect r EXTERIOR DOOR EQUAL OVER 3/4" drawn by C D V FURK STRIPS - �suedate: 07-06- 17 MTL. THRESHOLD 3Ya" GONG. SLAG w/ MF OR FIBERM SET IN SEALANT REVISIONS: REIN. OVER b MIL. PORCH SLAB VAPOR BARRIER date: Initlal: (SEE PLANS) 11-09-17 MK e -111=III=III=III= 12-11-17 MK 8"x8" THICKENED SLAB IN (1) #5 CONT. TH I CKENEP W&E DETAIL WAU, ,r',,a 8 CM BLOCK PROVIDE 30" MIN. LAP SPLICE (U #5 PERT. IN 3Y2" GONG. SLAB W 6ROUTED CELL, FULL WWF OR FIBERMESH HT. (SEE PLANS FOR REINF. OVER b MIL. LOCATIONS) VAPOR BARRIER ° . 4 11111- BREAK FACE SHELL TO ALLOW FOR 5LAI3 d. GRADE • GROUT 50LID —i (1= 11=1 1 BELGA 5LA6 DOWN -11 I- TO FOOTING O) #5 DONEL H/ b" ° . 9. 12"Ab" CONT. CONT. HOOK (SEE PLANS FT6. W/ (2) #5 HORIZ. FOR LOCATION) CONT. ON CHAIRS 0" °9d° MIN. COVER) II PROPPED GRAPE DETAIL SGAIA MS _1 I I � � �� � IIII=111=111=111=11' —i 11_111-1II III—III—III--_I 1-' '-1I1_1II—I I I—I 1' I I—III—III—_I I I III 111-111 '' 111-111 _ i—I I I L I I d ... —111T . CLEAN COMPACTEDII=ll=III m•:. I I I—III-; FILL 0 015% STANDARD DENSITY AND TERMITE=T III—�=1 I TREATED �- MONOLITHIC ' III=1 IT FOUNDATION W/ " (2) #5 HORIZ. -Q CONT. ON CHAIRS MIN. (3" MIN, COVER) WHERE 2ND STORY OCCURS FTG. SHALL BE t/ 1'-4" WIDE w/ (2) #5 BARS W J RY POOR 1 IT,41 L ° (D�N wm, S CBLOCK 11MU R4.1 FI -FOIL OR EQUAL OVER %4" r n (1) #5 FROM FT6. TO FURR STRIPS BOND BEAM. SPLICE r-1 To BE MIN. 30" 3 Y2,1 Cow. SLAB W GROUT CELL 50LID '^ NW OR FIBERMESH PORCH SLAB REINF. OVER b MIL VAPOR BARRIER (SEE PLAN) .d • _ .'° • • .4: . ° • '" I—III—III—III—III ,� �_ . • =1 I (—IIS 1 I =T� =1 11=1 11=1 111111 l— , Lt, EXPJOINT _ =1 I I—I I•• d'° °• I I—I 11—I i 1—, I ,� 0 =1 I iIT 4 III -1 11—_I 0 —III—i I ° I-111 11 W x MONOLITHIC W GLEAN '—1 111 I I I I I1 I I II 111 , . FOUNDATION N/ 5 COMPACTED FILL (2) #5 HORIZ. o q5% STANDARD I -Oil CONT. ON CHAIRS 0 DENSITY MIN. 0" MIN. COVEW z Q WERE 2ND STORY O z OCCURS FT6. SHALL BE (D 1'-4" NIDE W (2) #5 BARS 0 y q EXTERIOR WALL ® PORCH SLAB DETAIL L N 0 12 scar= N% sheet: SD 1 • (4)2%e "X0.113" R.5. TOE NAILS OVERFRAMIN6 ROOF 5HEATHIN6 VALLEY SET Aa'x0.113" R.5. NAILS ® 6 O.G. OVERFRAMIN6 TRU55 (EDGE NAIL) 018"XO.113" R.5. NAIL5 ® 6" O.G. FASTEN EACH MAIN ROOF 5HEATHIN6 OVERFRAMED TRU55 ." END TO ,TRU55 BELOW WITH (1) 51MP50N MT512 — — CLIP MAIN ROOF TRU555 TYP I CAL OYERFRAM I NG CONNECTION DETAIL SCALE: N.T.S. (1) #5 1N BOND BEAM iY } (1) #5 BAR IN PRECA5T LINTEL (2) #5's VERTICAL IN GROUT FILLED pC CELL. IN WALL5 6REATER THAN 30" } WIDE, ONLY (1) #5 15 REQUIRED - --- (1) #5 VERTICAL IN GROUT FILLED CELL (IF REQ'D PER PLAN) ENTIRE COLUMN TO BE GROUT FILLED 0:_O:: PROVIDE # OF DOWEL5 ® 5LAB TO FIN. FL. MATCH VERT. BAR5 w/ 30" MIN LAP 5PL16E NOTE: ALL HOOKS AND 5PLIGE5 TO BE GON5TRUGTED AND 51ZED PER NOTES &ARAGE DOOR @_�lRT.REINORGING i7ET IL Lt: NT5 TYPICAL TOP PLATE B LAP 5PL I GE DETAIL SCALE. N.T.S. DP PL 5 PLAN) 5HEAR WALL WITH EDGE NAILING t BLOCKING PER PLAN5. 51MP50N C51b 5TRAP CENTERED AT CORNER OF OPENING W (26) 2 1/2"x0.131" NAILS (26" MIN LEN(9TH) 2x4 HORIZONTAL FLAT BLOCKING. - IN5TALL 2 BAY5 IF FIRST STUD 15 LE55 THAN 14" FROM ED6E OF WINDOW OPENING. REQUIRED AT ALL OPENINGS GREATER THAN 3b" WIDE t AT 6LL.OPENIN65 LOCATED WITHIN P3 5HEAR WALL5. • NOT REQUIRED WHERE PORTAL FRAMES ARE 5PEGIFIED (5EE PLANS). • DETAIL 51MILAR AT BOTTOM CORNERS OF WINDOWS. TYPICAL EXT. WALL 4 INT. 5HEARAALL OPENING ELEVATION 2x4 LADDER BLOGKIN6 ® 161 0 VERTICALLY IN 15T STUD BAY FOR DRYWALL CONNECTION. FA5TEN BLOCKING AT EACH ENC WITH (2) 3"x0.131" TOENAIL5 TYPICAL 2 STUD CORNER ...MM.m....,.. _,. .. ............. .,, .w ,Fw�:,,,:o. ww,M.,r �,.A, �,»..x.�.,,;,,«,«,.,w�.:wx�.,,»...���.,...,�.,,..„..._..,........._.._.� .u. w.,m�m,%. .;.,�, ,:W...�.,.µ»».,,...«..,..u..:., .�...u.........,. i.....,.�,.�.w .«.....,. _�....,.w,�.,�yh.��:�.vw, TYP I CAL NOOD FRAMED WALL CORNER DETAIL SCALE: N.T.S. ALL LAPS IN MA50NRY 25" - RUNNING BAR —: #5 CORNER BAR GROUTED CELL TYP. CORNER VERT. WALL RE I NrDRG I NG DETAIL SCALE: N.T.S. SCAV== NTS 2x&12" P.T. (k OF OPENING CENTER BUGK--, I Y2" DIA. J -BOLT* (5EE BELOW) 2X4 P,T. TOP BUGK — 2X8 P.T. BUCK EACH 510E OF OPENING —PROVIDE (5))/2" DIA. J -BOLT'S W/ 5J/2" EMBEDMENT AT EACH DOOR BRACKET, EACH 510E OF DOOR. PROVIDE (1),V2" x 3i(a' THICK WASHER W/ EACH ANCHOR (15T BOLT TO BE 8" MAX ABV. CURB RE5T EQUALLY 5PAGED APPROXIMATELY 24" O.G) * PROVIDE Y2' DIA. x 6Y,2 LONG 51MP50N TITEN HD OR APPROVED EQUAL IN PLACE OF J -BOLT IF M155EP DURING CON5TRUGTION �t61 1 00R BUGK 17ET I L -N BOND-BEAM1111— _..,__---GONTIN. PREGA5T HEADER - ""' 8" GMU PIER ENTIRE COLUMN TO BE GROUT FILLED CAST-GRETE WINDOW SILL, OR EQUIV. --n GA5T-GRETE WINDOW 51LL, OR EQUIV. — DOUBLE NINDOA MASONRY PIER DETAIL L BCALt: NTS seal, 1/31/2015 w No 77824 d FA5TEN 2x P.T. WALL PLATE/ END P.T. d 5TUD TO GMU WALL w/ Y4" x 4" LONGS p. TAPGON 5GREW5 ® 16" O.C. ® INT. F TA � 2x INTERIOR WALL ��� 5HEARWALL END 5EE PLAN awn ��werom9®Q % Q copyright ; MULHERN & KULP Structural Engineering, Inc, ........... C _J 'm 'D � a a � dE m . Zry� 5HEARAALL INTER5ECTION WN y CONNECTION nETIL fl _ c C g ao , 19 v �Ui � N 4 M&K project number. NOTES: 181-17014 BOND -BEAM I. 2X PT BUCK5/NAILER5 SHALL EXTEND BEYOND INTERIOR FACE OF WINDOW, project mgr; SDI FA5TEN BUGK TO MA50NRY W/ (1) ROW OF 3i(a'x4" TAPCON5 6" FROM ENDS AND 16" O.G. MAX. TAPGON5 TO BE I Y2" MIN. FROM EDGE OF BUCK. drawn by. C DV REGE55ED 2. BUGK5 LE55 THAN 2X TO BE FASTENED W/ GUT NAILS OR EQUIVALENT. issue date: 07-06-1 7 PRECAST 5TRUGTURAL CONNECTION OF WINDOW TO 5TRUGTURE BY OTHERS IN TH15 HEADER GA5E. REVISIONS: 3. ADDITIONAL 2X WOOD BUCK MATERIAL MAY BE ADDED TO EXI5TIN6 2X date: initial: BUCKED OPENING, U5E (3) ROW5 OF 3"x0.131" NAIL5 5TA66ERED ® 12" O.G. 0 11-09-17 MK EA. 9UGGE551VE BUCK. 12-11-17 MK 4. MIXING OF IX AND 2X BUGK5 5HALL BE PERMITTED FOR THE 5AME OPENING IF WINDOW MANUFACTURER AND PLAN REOUIREMENT5 (FA5TENIN6) ARE MET. 5. ADDITIONAL WOOD BUCK MATERIAL MAY BE FA5TENED TO 2X 13UGK W/ (2) ROW5 OF 2Y2"x0.131" NAIL5 ® 16" O.G. FA5TEN WINDOW TO 2X PER WINDOW BUCK 5PEGIFIED MANUFACTURER'S 5PEG5. BY WINDOW/DOOR MANUFACTURER F�IIIJCK DETAIL ' .. � W M J Q LETTERED DETA I L5 ARE TYPICAL FOR NUMBERED DET, I L5 ARE PLAN TH 15 HOME � 5HALL BE IMPLEMENTED IN 5PEG I E I G AND ARE ONLY REOU I RED ALL APPLICABLE AREA5. THE5E NHERE 5PEG I E I GALLY INDICATED DETA I L5 ARE NOT "GUT ON THE PLAN5. ("GUT") ON THE PLAN5. ■ ■ ■ .a LL O J sheet :SD2*0 TOLERANCES: ALL DIMEN51ON5 TO BE HELD WITHIN +/-y4' OUT5IDE EDGE 015TANCE I" EDGE 1 I/2" E06E 2 1/2" EDGE PER DETAIL 3"x0.131"x3" COMMONQ,IQ II :: N I I :: N 1 1 :� z 1 1/2 2 1/2 2 1/4 2 N I I 3"x0.131"x3" I I Q INSIDE 2X'5 I I 3"x0.13111x3" GOMMON I PER DETAIL I 1 COMMON COMMON 3 Z OPP. 51DE z I I z I I z `0 1 1 3"x0.131 "x3" z II I I I I I I COMMON v II I I 5i I I `�' I I OPP.51DE II �n 11co 4 CL 015TANGE 3"x0.131"x3" PER DETAIL 41— COMMON (2)2X4'5 (2)2X6'5 (2)2X8'5 OPP. 51DE IN51DE PLY NAILS NAILED AT 8 O.G. 5TA66ERED. OUTSIDE OUTSIDE NAILS NAILED AT 8" O.G. (2)2X's (2)2X GOLUMN (3) OR (4)2X GOLUMN M 2X BUILT—UP STUD COLUMN VETA I L5 %AL1: NTS SEE DETAIL 20 ON STRUCTURAL PLANS FOR ADDITIONAL CONNECTION INFO NOT SHOWN HERE FASTEN EVERY OTHER 055 5LOGKIN6 ® 48" I -JOIST (w/ NEB BLOGKING A5 I-JO15T5 O.G. FA5TENED TO 2x REG D) TO 2x BLOGKIN6 w/ (1) -PER PLAN BLOCKING w/ (1) 51MP50N A35 CLIP 51MP50N A35 CLIP - FASTEN VERY OTHER J015T TO GMU w/ 51MP50N HT5MI6 TH15T STRAP. FASTEN 5TRAP TO GMU w/ (4))/4" DIA. x 2Y4" LONG TITEN 5GRE115 2x6 FLAT BLOGKIN6 (BETWEEN I -JOIST - 16" MIN. LENGTH) FASTENED DOWN TO LHU w/ (3) Y4" DIA. x 3 Y2' LONG TAPGON5 ® EA BAY. FASTEN RIM BOARD, THRU WALL 5HT6., TO 2x BLOGKIN6 w/ 3"x0.131 NAIL5 ® 3" o.c. Q RETRD I T PETAL L SCALE: 3/4"=1'-0" 5EE DETAIL 21 ON 5TRUGTURAL PLANS FOR ADDITIONAL CONNECTION INFO NOT 5HOWN HERE / I-JO15T5 -PER PLAN WO FASTEN LVERY OTHER J015T TO GMU w/ 51MP50N HT5MI6 TW15T 5TRAP. FASTEN STRAP TO GMU w/ (4),V4" DIA. x 2Y4` LON6 TITEN 5GREN5 2x6 FLAT BLOGKIN6 TO EA. SIDE OF 056 BLOGKIN6 (I6" MIN. LENGTH) FASTENED DOWN TO GMU w/ (3) Y4" DIA. x 3X2' LON6 TAPGON5. FASTEN RIM BOARD, THRU NALL 5HT6., TO 2x BLOGKIN6 w/ 3"x0.131" NAILS o 3" o.c. R RETROI= IT 1�ETA I L SCALE: 3/4"=1'-0" DBL. TOP PLT. BEYOND NAILING PATTERN PER NAILING 56HEOULE X X X F X N Y X X Y N F Y F N N X N N N N X N X - - - - N - - - - - - X N F X FLOOR 5Y5 M BEYOND N N X GMU WALL BEYOND NOTE: MIN fib" WINDSTORM OR EQUIVALENT NALL 5HEATHING TO BE USED A5 UPLIFT RE515TANGE, NO OTHER FA5TENER5 REO -D. EXCEPT A5 NOTED ON PLANS IN TWO STORY FRAME APPLICATIONS. NOTE: ACTUAL NUMBER OF FA5TENER5 NOT 5HOWN ELEV X DETAIL @15HEATHIN6 SGALC: NTS NOTES: I. UTILIZE 2 -PART EPDXY OR OTHER ENGINEER APPROVED EQUAL (I.E. SEE TYP. FOUNDATION 51MF50N ET EPDXY). DETAILS FOR ADDITIONAL 2. PROVIDE %# DIA. HOLE FOR DOWEL, INFORMATION NOT 5HONN BLOW OR BRUSH GLEAN. HERE 3. FOLLON MANUF. INSTALLATION INSTRUCTIONS. FUTURE 811 GMU BLOCK #5 VERT. BAR To BE LOCATED PER PLAN DRILL 6" INTO EXI5T'6 [L IN GROUTED CELL SLAB, EPDXY 4 DRIVE 1 1 #5 DOWEL, PROVIDE Ipp MIN. 30" LAP SPLICE = I I a e q �' b ° �" III—III—III—III—I I 1=1TI=1T=1TI=1 I ' I I IAPI I °' . • d . � as I I—III=1T_I=—i I 1='' ' 1I - M 155EP POAEL RETRO IT FETA I L WAa, NTS SIM. 0 GMU STCM FM vpamI CD 6001 seal. 1/31/2018 Se yid °E N ® �, No 77824 ti. SEE DETAIL 56 ON 5TRUGTURAL PLANS FOR °. ' TA F "I QV ADDITIONAL CONNECTION INFO NOT 5HONN HERE © copynlght;IMisULP FASTEN EA. ROOF TRU55 TO GMU Structural Engineering, Inc. w/ SIMPSON HT5MI6 TW15T STRAP. FASTEN STRAP TO GMU W (4) Y4' i s DIA. x 2 YW LONG TITEN 5GREW5 a' c PROVIDE MOISTURE BARRIER J ro PLATE (51MP50N T55 OR SIM) @ EACH TRU55. '� a PROVIDE 2x FLAT BLOCKING FIT "'' ® d0 TIGHT TO ROOF TRU55E5 @ EVERY OTHER BAY FA5TENED TO GMU w/ (3) z Y4" DIA. x 3Y2" LONG TAPCON5. �/ a FASTEN BLOGKIN6 TO ROOF TRUSSES LL w/ (2) 3 ANO.I3I" NAIL5 ® EA. END.}, A WW i. IC cn • N J Co. 17ET,�1 Cn amMETW71-10T L R CL � ._ � INSTALL ROOF CLIPS ROOF TRU55ES, ON OFF051TE FACE OF BEARING ON WALL NOTE: DETAIL ONLY WALL A5 STUD TIES AS WHERE NOTED ON PLAN APPLIES AT BEARING NECE55ARY NALL5 SILFFORTIN6 W Project number: ROOF TRU55E5. 181-17014 PROVIDE CRIPPLE Project mgr: SDI STUD ABOVE HEADER 4 JACK STUD drawn by: G D V 51MP50N RSP4 STUD issue date: PLATE TIE 9 TOP 4130T. O7"O6" 7 ROF 5TUD5, SPACED PER REFER TO PLANS FOR PLAN (ALT. PER PLAN: HEADER 51ZE. 05D SHEATHED WALL IN REVISIONS: FASTEN TO KING N/ LIEU OF METAL TIES) MIN. (3) 3"x0.131" NAILS date: initial' 11-09-17 MK 12-11-17 MK OPENING IN BR6. WALL 2x4 (MIN) 5TUD5 o 101 O.G. (5EE PLANS) OR AS NOTED ON PLANS NAIL 5TUD5 T06ETHER — - 7 1- — PER DETAIL M SL N P.T. 50LE PLATE PROVIDE SIMPSON DSP TO SLAB PER DETAIL 1 TIE OR (1) HS STRAP ® 3/5DI.0 U.N.O.ON PLANS BASE OF JACK 4 KING TO SOLE PLATE SLAB FOUNDATION CM IST LR. INTERIOR WOOP SEARING W I 0±§SGscCONNECTION BELOW ROOT+ MWJ N.T.S. U Z LETTERED DETAILS ARE TYP I GAL FOR NUMBERED DETAILS ARE PLAN TH 15 HOME � SHALL BE IMPLEMENTED IN 5PEG I E I G AND ARE ONLY REGU I RED ALL APDL I GABLE AREAS. THESE WHERE 5PEG I E) GALLY I ND I GATED DETAILS ARE NOT "GUT" ON THE PLANS. ("GUT") ON THE PLANS. sheep SD2* 2x EXTERIOR WALL -SEE PLAN FOR SHEATHING EXTERIOR WALL 5HT'G. TO 2x EXTERIOR WALL AND CONNECTION 5PEG5. UN CONTINUOUS FULL HEIGHT -5EE PLAN FOR SHEATHING R RUWALL FROM BOTTOM OF AND CONNECTION 5PEG5. EXTERIOR WALL 5HT'6. TO RIM TO DOUBLE TOP PLATE RUN GONTINUOU5 FULL HEIGHT FASTEN SOLE PLATE TO RIM w/ OF WALL FROM BOTTOM OF 2 Y2"x0.131" ® 3" O.G. INTO 3x0.131" NAIL5 1116' O.G. 4 5HEATHIN6 RIM TO DOUBLE TOP PLATE 50LE PLATE TO RIM w/ 2 2"x0.131" NAIL5 0 11 O.G. 2)2'x0.131° ® 3" O.G. INTO SOLE PLATE YS" (MIN) 055 RIM BOARD I I -JOISTS I )8" (MIN) 05B RIM BOARD. FASTEN TO EA. I-JO15T ®TOP I x -PER PLAN FASTEN RIM TO EA. BLK6 BOTTOM CHORD w/ (2) 3 Y4'x0.131" PANEL w/ (3)3 A4 "x0.131" NAIL5 NAIL5 MIN. 2 Y2"x0.131" ® 3" O.G. INTO RIM )2'x0.131 BOARD ° ' " ` 2 " @3" O.G. INTO RIM BOARD FASTEN RIM TO GMU BOND FASTEN EVERY OTHER I -JOIST (w/ WEB FASTEN RIM TO GMU BOND BEAM w/ 51MP50N HETAI6 BLOCKING BOTH 51DE5) TO BOND BEAM BEAM w/ 51MP50N HETAI6 EMBEDDED STRAP ® 24" O.G. w/ (1) 51MP50N HETAI6 (48" O.G. MAX) ' EMBEDDED 5TRAP ® 24" O.G. VERT WALL REINF. TO 8" GMU BOND BEAM VERT WALL REINF. TO EXTEND INTO BOND BEAM W/ (1) #5 CONT. EXTEND INTO BOND BEAM 8" REINF. GMU WALL 8" REINF. GMU WALL -5EE PLAN FOR VERT. -5EE PLAN FOR VERT. 4 HORZ. REINF. 5PEG5 8 HORZ. REINF. 5PEG5 @21;F1ION9/4"=I'-0' * PROVIDE 50LID SHIM BETW'N BILK'G & CONNECTOR IF BLK'6 LOCATED LE55 THAN I Y2" FROM CONNECTOR. WHERE BLK'6 15 GREATER THAN I Y2" FROM CONNECTOR, REFER TO TYPICAL RETROFIT 1I DETAIL R. 2x INTERIOR WILL ® 5TAIR5 OR WA. FASTEN SOLE PLATE TO RIM BOARD w/ 3"x0.131" NAIL5 ® 6" O.G. n�c � I Y8" FULL DEPTH 0513 BLOGKIN6 5EE UPLIFT CONNECTOR 48"i ALONG WALL (15T BAY ONLY) FASTEN 5HEATHIN6 TO EA. BLOCK w/ (5) #8 51 OR (5)2 Y2'x0.131" NAIL5. y l I -JOISTS x -PER PLAN -FASTEN EVERY 0513 BLOCKING TO BOND BEAM w/ (1) 51MP50H HETAI6 -SEE ARCH (48" O.G. MAX) GONNEGTOR 5PEGIFIGATION5 8" GMU BOND BEAM MW project number. W/ (1) #5 CONT. 181-17014 2D=SECTION projectmgr SDI -JO15T5 -5EE PLAN WALL GON5TRUGTION PER 5TRUGTURAL PLAN FASTEN FLOOR 5HEATHIN6 TO BLOCKING w/ 2 Y2"x0.131" 2x EXTERIOR WALL NAIL5 ® 6" O.G. -5EE PLAN FOR 5HEATHIN6 AND CONNECTION 5PEG5. II -JOI5T5 I Ye' 0513 BLOCKING EVERY -SEE PLAN OTHER BAY OVER 5HEAR WALL FASTENED w/ (2) 51MP50N A35 GLIP5 AT EACH BLOCK (PERPa @IENFTS/10 seal: 1/31/2018 70 '77 24 " 41 FASTEN ROOF 5HEATHIN6 TO 2x BLOCKING w/ 23/81 R.5. NAIL5 ® 6"O.C. TA Fr� 2x4 BLOGKIN6 IN EA. TRU55 BAY�� FA5TENED TO EACH GRO551 NG STUD w/ (2)3A2"x0.131" NAIL5 X11 ,9 ROOF TRUSSES Structural copyright: MULHERN & KULP Structural Engineering, Inc, ® 24"o.c• . FA5TEN 50LE PLATE OF WALL TO FLU5H J � BEAM w/ 3'1 NAIL5 ® 861 m c a 5HEATHIN6 5PLIGE 5HALL OCCUR OVER "C 2x 50LE PLATE w/ 2 Y2'x0.131" NAIL5 ®.�. a) E 3" O.G. OR PROVIDE CONT. 514%. TO BOTTOM OF FLU5H BEAM a Z� HANGER OR I Y8' 0513 RIM FASTENED w/ (I) II -BY TRU55 MANUF. W N 51MP50N A35 CLIP ® I6 ox.. _ OVER 5HEARWALL (PARALLEL) 11 FLU5H BEAM-/ -5EE PLAN 2� SECTION 2x4 GATS @ 16"O.G. FA5TENED TO GABLE END FASTEN 5HEATHIN6 TO 2x42x4 BLOGKIN6 w/ TRU55 w/ (2)31 BLOCKING w/ 23/8"X0.113" (3)3A4"x0.131" TOENAIL5. PROVIDE (I) R.5. NAIL5 ® 4"1 TOENAIL5 EACH END 2x EXTERIOR WALL ® 5TAIR5 51MP50N H3 CLIP I _\ r OVERHANGS > 12"III x x .FASTEN ROOF SHEATHING OR 2-5TORY 5PAGE _ " TO FASCIA WITH 23/8"X0.113" -5EE PLAN FOR 5HEATHIN6FA5TEN 50LE PLATE OF 2x WALL AND CONNECTION 5PEG5. [-TO BOND BM. IDIA. ANCHOR FASTEN ROOF SHEATHING TO PER ARPER ARCH FOR BOARD 11 1'-4" MAX 2'-0" MIN R.S. NAIL5 ®6" O.G. BOLT5 @ 6-0" MAX. PROVIDE a „ „ I FASTEN 50LE PLATE OF 2x WALL MIN. (2) PER PLATE AND MAX 12" FA501A WITH 2/8 X0.113 R.5. FIREPROOFING ROOF 5HT6 1 (4) 3Y4 x0.131 --1 � 7 TO BOND BM. w/Y2" DIA. ANCHOR FROM EA END NAIL5 ® 6 O.G. NAIL5 4' O" MAX PROVIDE GABLE END VERTICAL WEB 5HALL BE PROVIDE 50LID SHIM BETW'N TRU55 8 CONNECTOR IF TRU55 LOCATED LE55 THAN 1)z FROM CONNECTOR. WHERE TRU55 15 GREATER THAN I )2" FROM UPLIFT CONNECTOR, REFER TO TYPICAL RETROFIT DETAIL P. BOLTS ® - MIN. (2) PER PLATE AND MAX IT 2 ca 2x INTERIOR WILL ® 5TAIR5 OR WA. 0 _I CONT. 24 MIN URIED { REINFORGIN6 A5 REQONTO ROOF n�c � 5EE UPLIFT CONNECTOR v �� 2-5TORY SPACEINSIDE FAGS N y l 2x FA5GIA 5GHEDULE ON PLAN5 FOR 3 4 OF DRYWALL 5HALL OVERHAN6-� -T -SEE ARCH GONNEGTOR 5PEGIFIGATION5 FASTEN EXTERIOR 5HEATHIN6 MW project number. MA50NRY ". PROVIDE FURRING 3/4 181-17014 projectmgr SDI TO 2x PLATE w/ 2 )2°x0.131" drawn by: G D V I issue date. 07-06-17 PROVIDE MOISTURE BARRIER REVISIONS: MATCH DRYWALL 2x FASCIA date: initial: 8" GMU BOND BEAM 11-09-17 MK 12-11-17 MK 3 Y4"x0.131" TOENAIL5 ® 12" BOLTS ® - MIN. (2) PER PLATE AND MAX IT 2x INTERIOR WILL ® 5TAIR5 OR WA. 0 _I CONT. 24 MIN URIED { REINFORGIN6 A5 REQONTO ROOF - in `-� 5EE UPLIFT CONNECTOR FROM EA END �� 2-5TORY SPACEINSIDE FAGS BY TRO55 MANUF. 2x FA5GIA 5GHEDULE ON PLAN5 FOR 3 4 OF DRYWALL 5HALL OVERHAN6-� -T -SEE ARCH GONNEGTOR 5PEGIFIGATION5 FASTEN EXTERIOR 5HEATHIN6 MA50NRY ". PROVIDE FURRING 3/4 TO 2x PLATE w/ 2 )2°x0.131" ON IN51DE FACE OF MA50NRY TO z I PROVIDE MOISTURE BARRIER NAIL5 ® 3" O.G. MATCH DRYWALL 2x FASCIA 8" GMU BOND BEAM PLATE (51MP50N T55 OR 5IM.) -5EE ARCH 5EE UPLIFT CONNECTOR 3 Y4"x0.131" TOENAIL5 ® 12" W/ (I) #5 DONT. ®EACH TRU55. 8" GMU BOND BEAM w/ 2x 5HEAR WALL 5GHEDULE ON PLAN5 FOR O.G. GONNEGTIN6 BOTTOM 8" REINF. GMU WALL (1) #5 BARS CONT. - 5EE PLAN FOR CONNECTOR SPEGIFIGATIDNS CHORD TO TOP PLATE -5EE PLAN FOR PERT. VERT WALL REINF. TO 8" GMU WALL ---"- SPEGIFIGATIONS. FASTEN ROOF TRU55 TO FASTEN BOTTOM CHORD OF 8 HORZ. REINF. 5PEG5 EXTEND INTO BOND BEAM (5EE PLAN5) DOUBLE TDP PLATE w/ GABLE END TRU55 TO TOP ')„a PROVIDE 2x4 BLOCKING Anil ,, . ,.t ii T A2 t vAll (3) 3Y4"XOJZ ' IvMAILS PLATE WITH 51MP50N A35 „" , GLIP5 ® 32" O.G. T-BRAGE, SPACED ® BAYS OF ROOF 4'-1 O.G. MAX. FASTEN TRU55E5-GUT TO FIT 2x4 TO 'T' w/ 3)4"X0.131" T16HT BETWEEN TRU55 FA5TEN BOTTOM OF 2x4 NAIL5 ® 12" O.G. BOTTOM GHORD5 l�BRACE TO DBL. TOP PLATE Pq/ SECTION1'� I YINALL TO H2 5A 4 (203 YI' x�N' DETAIL BLO KrIN6Rw/5GREW5 WALCf 9/4"xi' .gZM_ 3/4TOENAILS I SCALE, 3/4"=I'-0" /NAIL5 ®6" O.G. 56 SECTION SGAl 9/4"=I'-0' LETTERED DETA I L5 ARE TYP I GAL FOR NUMBERED DETAILS ARE PLAN TH 15 HOME l$ 5HALL BE IMPLEMENTED IN 5PEG I F i G AND ARE ONLY REOU I RED ALL APDL I GABLE AREA5. THE5E INHERE 5PEG 1 E I GALLY I ND I GATED DETAIL5 ARE NOT "GUT" ON THE PLAN5. ("GUT") ON THE PLAN5. C N .fes■' W WMJ 2 (n z J LL IIJ - D W ° Zo dc0o � L- N O sheet SD2*2 N 0 _I I l � O 56 SECTION SGAl 9/4"=I'-0' LETTERED DETA I L5 ARE TYP I GAL FOR NUMBERED DETAILS ARE PLAN TH 15 HOME l$ 5HALL BE IMPLEMENTED IN 5PEG I F i G AND ARE ONLY REOU I RED ALL APDL I GABLE AREA5. THE5E INHERE 5PEG 1 E I GALLY I ND I GATED DETAIL5 ARE NOT "GUT" ON THE PLAN5. ("GUT") ON THE PLAN5. C N .fes■' W WMJ 2 (n z J LL IIJ - D W ° Zo dc0o � L- N O sheet SD2*2