HomeMy WebLinkAbout468 Rocky Grove Ln 18-2261 (a)LOT 281 - THORNBROOKE ANASTASIA - GARAGE RIGHT ELEVATION "TRADITIONAL - Aif TAYLOR MORRISON REDRAW NOTES 04-30-I0 CREATED LOT 5PECIFIC PLAN FOR LOT 281 IN THORNBROOKE, ELEVATION "TRADITIONAL - A", GARAGE RIGHT W/ PLAN OPTION5 INCLUDING: DECORATIVE RAILING AT MAIN AND UPPER FLOOR, POCKET 5LIDER AT GATHERING ROOM, 5411 DOORS, ALTERNATE STUDY, VENT HOOD AND MICRO OUTSIDE, PAVER5 AT ENTRY, WALK, AND PORCH, PRE -PLUMB LAUNDRY TUB, (3) MEDICINE CA5INET5, 5HAMP00 NICHE, FRONT DOOR GLA55 INSERT, CAN LIGHT5 AT OWNER'5 5UITE, GATHERING ROOM AND LOFT, TV BLOCKING AT GATHERING ROOM AND LOFT, PER50NALIZED HOME TECHNOLOGY, AND KEYLE55 PAD FOR GARAGE DOOR, `i SQUARE FOOTAGE CALCULATIONS ELEVATION "TR-A"' MAIN FLOOR LIVING S.F. 1467 UPPER FLOOR LIVING S.F. 1115 TOTAL LIVING S.F. 2582 GARAGE S.F. 455 PORCH S.F. 71 LANAI S.F. 139 TOTAL UNDER ROOF S.F. 3247 TOTAL WIDTH 30'-0"' TOTAL LENGTH 75'-0" DRAWING INDEX COV —GENERAL NOTES, INDEX, SPECIFICATIONS 1 — SLAB INTERFACE PLAN 2A1 — MAIN FLOOR PLAN NOTES 2A2 - MAIN FLOOR PLAN DIMENSIONS 2B1 - UPPER FLOOR PLAN NOTES 2B2 — UPPER FLOOR PLAN DIMENSIONS 3 — ELEVATIONS, ROOF PLAN, BUILDING SE T�.k ()7".1'1 (Qi11y FL1 — FLASHING DETAILS FL2 — FLASHING DETAILS REVIEWED Pf 1P E^f` OF COMPLIANCE 4A — MAIN FLOOR ELECTRICAL PLAN PLAN5"i FXAMINER DATE 4B — UPPER FLOOR ELECTRICAL PLAN TR -TRUSS STRAPPING SANFORD E3UR_f1'?1!,NQIII A FERMI i ,,;ai)L I ,rIAt.1 FsL Ct)N , I b;i Ir,D TO BE A N1 — 13 ANOTES STRUCTURAL LICFN�;E TO PROC EEC, WITH T�H(L WORK, A.ND NOT AS IOFAAt NY T�,,,1PRC)V-,((,ANGEL, HE OR SET ASIt1F ANY OF THE PROV15i,Tt�{;; OF THE TECHNICAL S1 -STRUCTURAL DETAILS CODES, NOR SHALL ISSUANCE OF A PERMIT PgEVENT ,, IIR Iii11L GOO CTIAN F RC:'M THEREAFTER IN 1-� Fi F'E�J�lIF-ilNG A CORRECTION t {: 1=RRORSIN PLANS, S2 STRUCTURAL DETAILS CONSTRUCTION OR VIOLATIONS IONS OF THIS CODE S3 — STRUCTURAL DETAILS COMPACTIOTO VEST S4 — STRUCTURAL DETAILS .OtUk,1 Results a1 Slab Axt�(e��rte<arr Sla to octico`e S5 — STRUCTURAL DETAILS TD — TRIM DETAILS S,h,I SD — STAIR TRIM DETAILS #18-2261 ii J fl I Ilk II I'' �c•�u GENERAL CONSTRUCTION NOTE5: CHAPTERS AND SECTIONS REFER TO F.B.C.R - 6TH EDITION (2011). NOTE: ANY DIMENSIONS AND/OR CALLOUT5 WITHIN THIS SET OF DRAWINGS REFERENCING LUMBER 51ZE5 OR WALL THICKNE55 ARE TO BE CONSIDERED "NOMINAL DIMEN6I01\15". ALL DIMENSIONS ARE TO ROUGH FRAMING UNLE65 OTHERWISE NOTED, OCCUPANCY AND CON5TRUCTION TYPE: THIS UNIT HAS AN R3 OCCUPANCY AND BUILDING TYPE V-8 CLASSIFICATION, EXTERIOR WALL ENVELOPE: BUILDER 15 RESPONSIBLE FOR PROVIDING AND MEETING ALL REQUIREMENTS OF 5ECTION 1012.4 OF THE F.BC.-BUILDING BY PROVIDING ALL DETAILS LISTED UNDER THI5 SECTION, INCLUDING BUT NOT LIMITED TO, THE MANUFACTURER'5 INSTALLATION INSTRUCTIONS AND ALL SUPPORTING DOCUMENTATION TO ENSURE THE WEATHER RE515TANCE OF THE EXTERIOR WALL ENVELOPE 15 MAINTAINED. CEILING CONSTRUCTION: THE GARAGE SHALL BE SEPARATED FROM THE RE5IDENCE AND ITS ATTIC AREA BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LE55 THAN 5/6 INCH (15.9 mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION 15 A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL AL50 BE PROTECTED BY NOT LE55 THAN 1/2 INCH (12.1 mm) GYPSUM BOARD OR EQUIVALENT IN ACCORDANCE WITH FB.CR - 6TH EDITION (2011) R302b AND TABLE R3021o. ATTACHMENT OF GYPSUM BOARD SHALL COMPLY WITH TABLE R10235. EXTERIOR FIN15HE5: INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER F.B.C.R. - 6TH EDITION (2011) R103.1.1 AND ASTM C 1063. ALL LATH AND LATH ATTACHMENTS SHALL BE OF CORRO5ION-RE515TANT MATERIAL. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 11/2 INCH II GAUGE NAILS HAVING A 1/16 INCH HEAD, OR 116 INCH LONG 16 GAUGE STAPLES SPACED NO MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED. THICKNESS OF TEXTURED FIN15H OVER FRAME APPLICATION TO BE PER FB.C.R - 6TH EDITION (2011) R103.1.2 AND ASTM C $26, PER M.C.R. 6TH EDITION (2011) R103.12.1 WEEP 5CREED5 SHALL BE A MINIMUM NO.26 GALVANIZED SHEET GAUGE GORRO510N-RE515TANT WEEP SCREED OR PLASTIC WEEP 5GREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 ',INCHE5 SHALL BE PROVIDED AT OR BELOW THE PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C %6. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE PAVED AREAS. THE WEATHER RE515TANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP 5GREED. PER FB.CR 6TH EDITION (2011) R103.13 WATER RE515TIVE BARRIERS INSTALLED OVER WOOD BASED SHEATHING SHALL INCLUDE A WATER RE515TIVE VAPOR PERMEABLE BARRIER EQUIVALENT TO 2 LAYERS OF GRADE D PAPER, STUCCO APPLICATION AND CURING PER FB.C.R 6TH EDITION (2011) R103.1.5 OR IN ACCORDANCE WITH ASTM C $26. 5TUCCO CONTROL JOINT: STUCCO CONTROL JOINTS TO BE INSTALLED PER ASTM C 1063-06 (1.11.4.1 TI4% 1.11.4.4) AT FRAMED WALLS TO DELINEATE AREAS NOT MORE THAN 144 S,F. AND DELINEATE AREAS NOT MORE THAN 100 SF, FOR HORIZONTAL APPLICATIONS. D15TANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18 FT, IN EITHER DIRECTION OR A LENGTH -TO -WIDTH RATIO OF 21/2 TO 1. A,CONTROL JOINT SHALL BE INSTALLED WHERE CEILING FRAMING OR FURRING CHANGE DIRECTION, AND WHERE EXPAN51ON JOINT OCCURS IN BASE EXTERIOR WALL. WALL OR PARTITION HEIGHT DOOR FRAMES SHALL BE CON5IDERED A5 CONTROL JOINTS. EGRE55: EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRE55 CODES, IF THERE 15 NO AGGE55 TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST HAVE A MAXIMUM CLEAR OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM. FLASHING: I. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, DECK AND WALL INTERSECTIONS, AT GUTTERS, AT ALL CHANGES IN ROOF SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS. 2. APPROVED CORRO6ION-RE515TANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORRO6ION-RE516TANT FLASHING SHALL BE INSTALLED AT ALL REQUIRED LOCATIONS PER R103.4. WINDOW INSTALLATION: 1. WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE MANUFACTURER FOR EACH WINDOW. 2. IF STRUCTURE 15 IN A WIND-BORNE DEBRIS ZONE, AND REQUIRES PROTECTIVE SHUTTERS OR IMPACT GLASS, THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR DETERMINING WHICH PROTECTIVE METHOD 15 TO BE USED. DWELLING / GARAGE OPENINGS: THE OPENING BETWEEN THE GARAGE AND LIVING AREA SHALL BE EQUIPPED WITH 50LID WOOD DOORS NOT LE55 THAN 13/8" IN THICKNESS, SOLID CORE (5,C.) OR HONEYCOMB CORE STEEL DOORS NOT LE55 THAN 1 3/8" THICK, OR 20 MINUTE FIRE RATED DOORS. FLOOD ZONE REQUIREMENTS: PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION, IF FLOOD PORTS ARE REQUIRED IN GARAGE, REFER TO PLAN FOR CALCULATIONS AND QUANTITY. ASPHALT 5HINGLE5 (IF APPLICABLE) : 1. WIND RESISTANCE OF ASPHALT SHINGLES. - ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION M052b AND RW52161 2. ASPHALT 5HINGLE5 SHALL ONLY BE USED ON ROOF SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR GREATER. FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LE55 THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT COMPLYING WITH ASTM D 226, TYPE I OR TYPE 11, ASTM D 4869, TYPE II OR TYPE IV OR A5TM D 615115 REQUIRED IN ACCORDANCE WITH SECTION R905JJ. FOR ROOF SLOPES FROM FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4,12) AND GREATER, ONE LAYER OF UNDERLAYMENT COMPLYING WITH ASTM D 226, TYPE 11, ASTM D 486% TYPE IV OR AS111 D 615116 REQUIRED IN ACCORDANCE WITH SECTION RW5,11 CLAY AND CONCRETE TILE (IF APPLICABLE) THE INSTALLATION OF CLAY AND CONCRETE TILE PER FB.C.R - 6TH EDITION (2011) RW53 SHALL BE IN ACCORDANCE WITH THE MANUFAGTURER'5 INSTALLATION INSTRUCTIONS, OR RECOMMENDATIONS OF FR5A/TRIFLORIDA HIGH WIND CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL,FIFTH EDITION WHERE THE VABDIS DETERMINED IN ACCORDANCE WITH SECTION R3012.13 OR THE RECOMMENDATIONS OF RAS II8,119 OR 120. REQUIRED UNDERLAYMENT PER FB.CR - 6TH EDITION (2011) RW533 SHALL CONFORM WITH ASTM D 226, TYPE 11; ASTM D 2626, TYPE II; OR ASTM D 1910 OR ASTM D 6380, CLASS M MINERAL 5UI:ACED ROLL ROOFING AND SHALL BE INSTALLED IN ACCORDANCE WITH FR5A/TRI FLORIDA HIGH WIND CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL, FIFTH EDITION WHERE THE VABD 15 DETERMINED IN ACCORDANCE WITH SECTION R3011.13 OR THE RECOMMENDATIONS OF RAS 118,119 OR 1210, CHIMNEY HEIGHT REQUIREMENT5 (IF APPLICABLE) : WHEN STANDARD OR OPTIONAL FIREPLACE 15 TO BE INSTALLED THE CHIMNEY MUST EXTEND 34" PAST THE HIGHER POINT WHERE IT EXTENDS THROUGH THE ROOF AND MUST BE 24" HIGHER THAN THE ROOF OR RIDGE THAT 15104" AWAY OR CLOSER. TUB AND SHOWER AREAS: CEMENT, FIBER -CEMENT, OR GLASS MAT GYPSUM BOARD (NO GREEN BOARD ALLOWED) IN COMPLIANCE WITH ASTM C1288, C1325, OR CI118 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS, AND WALL PANELS IN SHOWER AREAS, TERMITE PROTECTION: 1, PENETRATION. PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE 5LA5-ON-GRADE FLOORS SHALL NOT BE OF CELLULOSE CONTAINING MATERIALS. IF 501L TREATMENT 15 USED FOR SUBTERRANEAN TERMITE PROTECTION, THE SLEEVE SHALL HAVE A MAXIMUM WALL THICKNE55 OF 0,010 INCH, AND BE SEALED WITHIN THE SLAB U51NG A NON-CORR051vE CLAMPING DEVICE TO ELIMINATE THE ANNULAR SPACE BETWEEN THE PIPE AND THE SLEEVE. NO TERMITICIDES SHALL BE APPLIED INSIDE THE SLEEVE. 2. PROTECTION AGAINST DECAY AND TERMITES. - CONDENSATE LINES, IRRIGATION / SPRINKLER SYSTEM R15ER5 FOR SPRAY HEADS, AND ROOF DOWNSPOUTS SHALL D15CHARGE AT LEAST I FOOT (305 mm) AWAY FROM THE STRUCTURE 51DEWALL, WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS WITH EAVES OF LE55 THAN 6 INCHES (152 mm) HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER ROOF. MECHANICAL AND HVAG. I. ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AS AN ATTACHMENT TO THI5 PLAN SET AT THE TIME OF APPLICATION FOR PERMIT. 2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION; OTHER APPLIANCES, OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR REPLACED, A LEVEL WORKING SPACE AT LEAST 30 INCHES (162 mm) DEEP AND 30INCHES (162 mm) WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. 3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. 026 GAUGE (0.46 mm) 5HEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL 5Y6TEM6 SHALL BE RA15ED AT LEAST 3 INCHES (16 mm) ABOVE THE FINISHED GRADE AND SHALL AL50 CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. AUXILIARY DRAIN PAN, CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROV1510N5 OF SECTIONS M1411.3. EXHAUST FANS AND VENTING: 1. OUTDOOR D15CHARGE, THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR CRAWL SPACE, 2. EXHAUST AIR FROM BATH ROOMS AND TOILET ROOMS SHALL NOT BE RECIRCULATED WITHIN A RE5IDENCE OR TO ANOTHER DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT D15CHARGE INTO AN ATTIC, CRAWL SPACE, OR OTHER AREAS IN51DE THE BUILDING, 3. DUCT LENGTH, THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 35 FEET FROM THE DRYER LOCATION TO THE WALL OR ROOF TERMINATION. IF DUCT LENGTH EXCEEDS 35' THEN PERMANENT LABEL OR TAG MUST BE INSTALLED. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET (162 mm) FOR EACH 45 DEGREE (0,19 RAP) BEND AND 5 FEET (1524 mm) FOR EACH 90 DEGREE (1.6 RAD) BEND, THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. EXCEPTION - WHERE A CLOTHES DRYER BOOSTER FAN IS INSTALLED AND L15TED AND LABELED FOR THE APPLICATION, THE MAXIMUM LENGTH OF THE EXHAUST DUCT, INCLUDING ANY TRANSITION DUCT, SHALL BE PERMITTED TO BE IN ACCORDANCE WITH THE B005TER FAN MANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE A CLOTHES DRYER 5005TER FAN IS INSTALLED AND NOT READILY ACCESSIBLE FROM THE ROOM IN WHICH THE DRYER 15 LOCATED, A PERMANENT IDENTIFYING LABEL SHALL BE PLACED ADJACENT TO WHERE THE EXHAUST DUCT ENTERS THE WALL. THE LABEL SHALL BEAR THE WORDS "THI5 DRYER EXHAUST SYSTEM 15 EQUIPPED WITH A REMOTELY LOCATED 5005TER FAN." 4. PROVIDE LOUVER DEVICES AT INTAKE AND EXHAUST LOCATIONS IN ACCORDANCE WITH AMCA STANDARD 550 IN FBC. ATTENTION GENERAL CONTRACTOR / BUILDER: ISSUANCE OF PLANS FROM THI5 DRAFTER'5 OFFICE SHALL NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. ANY D15CREFIANCY OF ERROR IN NOTES, DIMENSIONS, OR ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER'5 OFFICE FOR CORRECTION BEFORE COMMENCEMENT OF ANY CONSTRUCTION CORRECTION / REVISIONS. ANY REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE AFTER THE FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE DRAFTER'S OFFICE, THE DRAFTER SHALL NOT BE HELD RESPONSIBLE. REV,12-31-2011 `v�\� 183,3,III�> s � 6 r s // / °°.....®° ®� % bda o+ `°®a®® • x ro T"to �0ID00 OJI�Qj 0 1 m N Lo ooLL • 00 :25-� `0� ro00 LIII J*C4 0 �00 T� Z N G 0 • JOB NUMBER B-1812154• CAD FILE NAME LOT 281 BASE 01-04-18 ISSUED 04—JO-18 SO BEWS DESIGN GROVP 150 STATE STREET EAST C7LDSMAR, FLUR.IDA 34677 813.925.1340 TEL 813 . 925.1800 FAX W W W.DAVISBEW&C.OM TAMI'A • DENVER. - EST. 1994 VORTEX ENGINEERING, LLC. 607 S. ALEXANDER ST., SUITE 103 PLANT CITY, FLORIDA 33S63 813.704.4842 COA 28035 PAUL D. KIDWELL, P.E. #52683 ANDREW J. MEISHEID, P.E. #83217 I HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED DESIGN, AND FIND ITTO BE IN COMPLIANCE WITH SECTION R301 OF THE FLORIDA BUILDING CODE, RESIDENTIAL 6TH EDITION (2017). THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUF. LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER. SEALED FOR STRUCTURE ONLY 0 0 0 000 Lil O N O Q DAVIS IVI�� 2582 " TITLE GENERAL NOTES REVISION LOG cov • SHEETLO • FIR 0 1411 8'-4" 4'-411 4'-8" 4'-811 41-811 41-01' 1'•0" 5'-4" 5'-411 4'-411 4'-10" 3' 6" 4'-411 4'-0" 4'-411 2 STORY I STORY FOOTING FOOTING p 3'-0" F4 -/ SII 51 H$. eo co ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ c0 ■ ■ ■ ■ ■ P/7 - 747/1 eCk iI � 8II 8 „ 50 GAL. 1-STORY SOOTING (tYP.) WIDEN FOOTING 8" AT ■ I I I� I I I 9s. J I I 20" H. x 16" W. GONG. MONO-FTG, W/ i 2 "5 CONT. REBARS PROVIDE G.C. VERIFY ACRYLIC ON LANAI I POCKET SLIDER AND 05 I I ca 51 III [`'] I`" 16" Wxl6" DEEP FTG. = I 25" MIN. LAP WHERE SPLICED AND I WIRE TOGETHER. 50TT. OF FTG. ADD (1) REBAR 9'-8" I 31'•10" — -� W/ 2 - 05 CONT. I I I 9 -I 3 9 I SHALL BE 12" MIN. BELOW GRADE 20.0 I 8„ o ( A ELEVATION AT 0'-0" (ASSUME[)) / \ IIa REF. N -' � '- I 3.5 THICK, 2500 OR 3000 P.5.1. CONCRETE SLAB ON GRADE W/ I i� — �u 3 -6 16" Wx16" DEEP FTG. SLAB W/ 2 'B CONT. GJ. ---'--- I C.J. J ---------------`---- ---------------`---`- AA w PITCH 6x6 WL4xWl.4 MESH OR FIBER v - MESH OVER 6 MIL. VAPOR BARRIER ON CLEAN, WELL PROVIDE WATER 2. LINE FOR ICE MAKER / PITCH TO DRAIN 811x8" FTG. W/ I s COMPACTED, TERMITE TREATED, / ;9 �>r I CONT. (TYP. AT LANAI) GRANULAR FILL. G� i w 41-411 51-411 • ■ ■ ■FE�� 3/4" CONDENSATION � NOTE: ALL SLAB ANGLES i LL, _ /�L// /�l/2U DRAIN BY PLUMBER ARE AT 45° lUN.O.) _� 9,_811 21'-611 21 / II 12' 311 4'-11" 2'-1" PRE -PLUMB = ■ 2-5TORY FOOTING (TYP,) r3 n, 16" W.x12" DEEP FTG. 5 W/ 2 - "5 GONT. 51G LT. _ 1'-311 4E, / 1=1 2'-5" I I 811 I 20" H. x 20" W. GONG. MONO-FTG. _ - AIR HANDLER \ LINES FROM 3/4" RECESS W/ 3 - S CONT. REBAR5 PROVIDE / / 3' 8" UPPER FLOOR FOR ENTRY 5'-2" 5' 8" 4' 0" 4'-411 25" MIN. LAP WHERE SPLICED AND 3' WIRE TOGETHER BOTT. OF FTG. SHALL BE 12" MIN. BELOW GRADE II I I 4" P.V.C. 16 Wx16 DEEP FTG. ■ W/ 2 - 05 CONT. I , ■ ■ ■ ■ I STORY N I $ I "` 8" THICKENED EDGE I I M I 14'-4" rt OF 2x4 WALL L FOR SHOWER RECESS I W/ I NO, 5 BAR CONT, `�' FOOTING u c — , I I II " LAY. 4'-211 3'-111 2'-811 AIR HANDLER _ 13' 8" ti S� 0�� I 8"x8" FTG, W/ I - 05 �_ - 20 11 - -all - 2 I 18 3 I LINES FROM ` " - �' 5' 4" CONT. (TYP. AT ENTRY) 13' 8" �' `� J 6, UPPER FLOOR ■ T 's TILE SHOIUER �I "` OPT. , u 3 8 I u 19 -0 SEAT RECESS DRYER A ■■ ASV, -011 PAYERS PAYER DRIVE LEAD WALK = CONDENSATION DRAIN BY PLUMBER 5'-6"3/4" IiIIWA6NER I ��LAV — — — — — — ■ ■ ■ ■ ■ 8"CM.U. WALL ABv. ■ lb ■ ■ ■ ■ = - H.B. INDICATES I - S VERT. REBAR IN MASONRY CELL FILLED 50LID W/ CONCRETE. VERT. REINF. SHALL BE HOOKED INTO BEAM ABOVE 4 FTG. BELOW PROVIDE 25" MIN. LAP WHERE 4'-4" SPLICED AND WIRE TOGETHER 4'•8" rltvN i iuN 4" P.v.C., ( ) 0' 3 IMII 3/4" CONDENSATION DRAIN BY PLUMBER 4'-8,1 41•QII 414 I 31.811 41-211 V 52'-411 21.411 \_811 C.M.U. WALL ABY. -)I [ II 21_/ II PITCH P4 1/8" / FT. LI u1 w 4'-411 1'-4" 1'-811 13'-811 TAYLOR MORR15ON U5E5 50RA-CARE TO TREAT THE INTERIOR FRAMED WALLS TO PREVENT SUBTERRANEAN TERMITES G.C. VERIFY THAT DECO DRAIN 15 INSTALLED AT PLANTERS BETWEEN WALKWAY AND GARAGE * * * * * ,��01111If0�I/ `ems •• •.....� � i Q • o ... :w • : z 0: e� �i�f 'mill ELEVATION (-) 0'-4" INDICATED ON TH15 PLAN WILL BE EQUAL TO OR GREATER THAN THE EBTA51_15HED N.A.V.D. (NORTH AMERICAN VERTICAL DATUM) MINIMUM TOP OF SLAB ELEVATION AS REQUIRED BY FEMA TO OMIT HYDROSTATIC VENT REQUIREMENT. PLEASE REFER TO 51TE PLAN SUBMITTED FOR DEVELOPMENT ORDER APPROVAL AND INDIVIDUAL LOT PLANS TO DETERMINE SPECIFIC REQUIREMENT FOR EACH USE OF TH15 PLAN, ALL GARAGE FLOOR ELEVATIONS WILL MEET OR EXCEED THE MINIMUM REQUIRED FINISH FLOOR ELEVATION FOR ANY STRUCTURE BUILT IN A FLOOD DESIGNATION AS SPECIFIED BY FEMA AND LEE COUNTY LDG CHAPTER 6, ARTICLE IV FLOOD HAZARD REDUCTION. FOOTING LEGEND: 0 12" DEEP x36"x3611 GONG. FOOTING W/ (4) "5 BARB EACH WAY. G 12" DEEP x24"x24" GONG, FOOTING W/ (3) S BARS EACH WAY, G 20" DEEP x30"x30" GONG. FOOTING W/ (3) S BARS EACH WAY x ro u)0 0a�o O _j co t% ♦♦AA Y/ I 2cooMm Lo ? j J N 66 QoLL 0 0 .-0.0ti LI.Y '•OI ;: c', 00 Zcu'v�t JOB NUMBER B-1812154 CAD FILE NAME LOT 281 BASE 01-04-18 ISSUED 04-30-18 DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDWAR, FLORIDA 34677 813. 925.1300 TEL $13.925.1800 FAX W W W.DAVISBEWS.COM TAMPA » DENVER. EST.1994 r-'62 F1111111 VORTEX ENGINEERING, LLC. 607 S. ALEXANDER ST., SUITE 103 PLANT CITY, FLORIDA 33563 813,704.4842 COA 28035 PAUL D. KIDWELL, P.E. #52683 ANDREW J. MEISHEID, P.E. #83217 I HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED DESIGN, AND FIND IT TO BE IN COMPLIANCE WITH SECTION R301 OF THE FLORIDA BUILDING CODE, RESIDENTIAL 6TH EDITION (2017). THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUF. LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER. SEALED FOR STRUCTURE ONLY W .Iri..■ 0 0 O 000 N >7 0 _< ou Vo 1=4 12" DEEP x30"x30" GONG. FOOTING W/ (3) 05 BARS EACH' WAY. 2582 THE FOUNDATION 5Y6TEM HAS BEEN DESIGNED U51NG A MINIMUM ' 501L BEARING CAPACITY OF 2000-P6F (R401.4. I FBGR). TITLE FOUNDATION PLAN OPT. ALT. DEN FINDICATES I S OPT. POCKET S.G.D. OPT. O.D.K.S 2 wo - FOUNDATION PLAN GARAGE RIGHT TYPICAL MASONRY WINDOW SCHEDULE WINDOW WIDTHS q� I 2011 2111 3111 5311 rf WINDOW CALL -OUTS 3: (D 2611 12 5H 1/2 32 5H 22 5H 32 5H w = 3911 0 13 5H 1/2 33 5H 23 5H 33 5H 0 51" 14 5H 1/2 34 5H 24 5H 34 5H z 63" A 15 5H 1/2 35 5H 25 5H 35 5H Z 12" �s 16 5H 1/2 36 5H 26 5H 36 5H G.G. VERIFY MA50NRY OFENING5 FOR ALL WINDOW5, Lu w WINDOW 51ZE5 AND IN5TALLATION MAY VARY FER 8 MANUFACTURER AND 5FECIFICATION5. z REFER TO FLOOR FLAN5 FOR 5TYLE OF WINDOW U5ED (5INGLE HUNG-51-1, GA5EMENT- G5MT, OR FIXED GLA55- F.G.) ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL COMPLY WITH R310 PER F.B.C.R. - 6TH EDITION (2011). v a� ()TYP. ARCHWAY ASCALE: 1/4" : 1411 STAIR NOTES SEE SHEET DTI FOR STANDARD STAIR DETAILS AND NOTES. SPECIFICATION FOR LANDINGS AND STAIR CONSTRUCTION: (THE FOLLOWING SHALL APPLY UND.) • ALL STRINGERS TO BE 2-2x12 " SYP. • ALL SPRINGERS TO ATTACH AT LANDINGS AND UPPER FLOOR LEVELS WITH 6IMP50N L5C HANGER • STRINGERS RUNNING PARALLEL TO AND SUPPORTED BY A WALL SHALL BE ATTACHED: •• AT M45ONRY/GONG, WITH 114 DIA x 3" TAPCON6 AT 8" O.C. STAGGERED ALONG THE LENGTH OF THE STRINGER (USE PT AT MAS./GONG.). •• AT WOOD WITH (4) 0.131 x 31/2" NAILS AT EA. STUD MIN. (16 O.G. MAX) •• IF STRINGERS ARE SUPPORTED IN TH15 WAY, L5U HANGERS ARE NOT REQUIRED AT THE ENDS • ALL STRINGERS SPRINGING FROM A FLAT SUI;r-ACE SHALL TERMINATE AT A 2x4 FOOT (TO BE PT AT GONG.). ATTACH FOOT TO FLOOR: •• AT GONG. W/ 1/4" DIA. x 3" TAPCON5 AT 12" O.G. •• AT WOOD ATTACH W/ 0,131 x 31/2" NAILS AT 8" 0,0, TO TRU55/JOI5T/ OR BLOCKING BELOW. •• ATTACH STRINGER TO FOOT WITH (2) 0.131 x 31/2" TOENAILS EA. • LANDINGS SHALL BE BUILT AS FOLLOWS: •• J015T5 TO BE 2x8 " 5YP, MIN, AT 16" O.C. of IF LANDING INCLUDES STRINGER SUPPORT IN A BEAM CONFIGURATION, BEAM SHALL BE (2) 2x12 "2 5YP WITH 2-2x4 SUPPORT STUDS AT EACH END. of IF LANDING 16 SUPPORTED BY A KNEEWALL, PROVIDE A 2X8 END J016T WITH (3) 0.131 x 31/2" R.5, END NAILS AT EACH LANDING JOIST, AND (2) 0.131 x 31/2" TOE NAILS FROM EACH J015T TO KNEEWALL TOP PLATE. of LEDGERS TO BE 2x8 WITH: a• (4) 0.131 x 31/2" NAILS AT EACH PA551NG STUD AT WOOD ATTACHMENT 16" O.C. MAX. •f• 1/4" x 3" TAPGON5 AT 8" O.G. STAGGERED AT MA50NRY/CONCRETE ATTACHMENT. to ATTACH JOISTS TO LEDGERS OR BEAMS WITH SIMP50N LUS26 HANGERS OR EQUAL. • THE SPECIFICATION LISTED ABOVE OR MINIMUM SPECS. SUBSTITUTIONS OF EQUAL OR BETTER CAPACITY ARE ACCEPTABLE. BOTT. OF LINTEL AT 8'-0" A,F.F. F_---7 1 3'-6"x3-6" A/G PAD (SEE MECH. CONTRACTOR FOR LOG.) L_.._ - r 3'6" A/C � PAD (SEE MECH. CONTRACTOR FOR LOC.) L__- OPT. 6" TRAY GLG, IN MASTER SUITE G.C. VERIFY SHIM AS POP-UP OUTLETS REQ//D 111 CASING 2x STUDS (PER 5TD. PLAN) BASE CABINET 1/16 0.5.5. BACKING L 1/2" DRYWALL L CALI. TOP SCALE: 1/2" : I'_011 AT VOLUME CEILING HATCHING INDICATES DOUBLE STAIR SECTION. SCALE: 1/4" : 1411 u1-I GIB FI-VVN HANSEN BOX BELOW PREC45T LINTEL 'AIR NOTE5: LING aLU5TERS SHALL BE SPACED 50 THA1 4" SPHERE CANNOT PASS THROUGH. ,NDRAIL5 ,NDRAIL5 FOR 5TAIRWAY5 SHALL BE )NTINUOU5 FOR THE FULL LENGTH OF E FLIGHT, FROM A POINT DIRECTLY 3OVE THE TOP R15ER OF THE FLIGHT I A POINT DIRECTLY ABOVE THE )WEST RISER. HANDRAIL ENDS SHALL : RETURNED OR SHALL TERMINATE IN :WEL POSTS OR SAFETY TERMINALS, NDRAIL5 ADJACENT TO A WALL SNAL EVE A SPACE OF NOT LE55 THAN 1-1/2 ;H BETWEEN THE WALL AND NDRAILE )NTINUOU6 GRASPABLE HANDRAIL 16T MEET TYPE ONE OR TYPE TWO 21TERIA I G.C. VERIFY TOP OF TILE TILE TO WRAP INTO NICHE G.C. VERIFY LOCATION TYP. SHAMPOO NICHE SEE FLOOR PLAN FOR EXACT LOCATION FLAT HEADER AT S'-0" A.F.F. 1 1,41N FLOOR STRUCTURAL LEGEND 8 K.O. BLOCK FILLED W/(U "5 BAR OVER 8 0 - PRE-ENGINEERED CONCRETE LINTEL FILLED WI(l) 05 BAR. 1A — 8" K.O. BLOCK FILLED W/lU S BAR GONT. OVER 8" COMMON BLOCK COURSE OVER 8" PRE-ENGINEERED CONCRETE LINTEL W/ll) 05 BAR, GROUTED SOLID. • 8" PRE-ENGINEERED CONCRETE LINTEL 05 FILLED W/lU BAR FIZI 0 — 8" LINTEL5 SHALL BE FILLED, BELOW 8" K.O. BLOCK FILLED AND REINFORCED WI(l) S BAR ® — PROVIDE (4) 2x4 STUDS W/ lU 51MP50N HTT4 CONNECTORS AT BASE. 05 — PROVIDE (3) 2xb STUDS W/ (1) 6IMP50N HTT4 CONNECTORS AT BASE. ® — PROVIDE 2-PLY 2x12 NO.2 SYP BEAM W/ 1/2" 055 FLITCH PLATE, TIED TO DOUBLE JACK-5TUD5 AT EACH END WITH (1) 51MP50N L5TA15 STRAP. THE JACK-5TUD5, IN TURN, MUST BE TIED TO THE BOTTOM PLATE WITH (2) SIMPSON H25 CLIPS, STRUCTURAL NOTES • ALL LVL'5 TO BE Fb:2S50 P51 MIN, • ALL WOOD LOAD BEARING HEADERS TO BE (2) 2x8 02 5YP U.N.O. • ALL EXTERIOR WALLS TO BE CONSIDERED SHEAR RE615TING COMPONENTS • NOT A SPECIAL FLOOD HAZARD AREA NOTE: C.J.: RECOMMENDED MA50NRY CONTROL JOINT. F■ INDICATE51 "5 ♦ INDICATES 2 4S 11,' ``'t111111 s w d .r :w O ' Z z 1 �I +e 4. ��•y+ HATCHING LEGEND LOAD BEARING WALL;�:�393•ee3S:�e INSULATE WALL R - Value Chart WALL CONSTRUCTION R-VALUE (MIN.) FRAME WALLS (WHERE APPLICABLE) R 13 CLG. INSULATION R 38 MA50NRY WALLS R 4.1 KNEE WALL R 30 GARAGE FRAME WALLS R 13 MAIN FLOOR PLAN NOTES GARAGE RIGHT x C 10 U ~o o� O Jc�il�� 1 o_ = V) W L 1n CM >>J 4 66 0 n am 0 0j cO E u.�roc°v C0 +iD �~ Oo ZN�l01 JOB NUMBER B-1812154� CAD FILE NAME LOT 281 BASE 01— 04-18 ISSUED 04-30-18 003 jA__ DAMS BEWS DESIGN GROVP 150 STATE STREET EAST OLDSMAR, RORMA 34677 813.925.1300 TEL 813.925.1800 FAX WWW.DAVLSBEWSCOM TANAPA • E>ENVE k — = EST. 1994 Fes_ -- �116 �111 VORTEX ENGINEERING, LLC. 607 S. ALEXANDER ST, SUITE 103 PLANT CITY, FLORIDA 33563 813.704.4842 COA 28035 PAUL D. KIDWELL, P.E. #52683 ANDREW J. MEISHEID, P.E. #83217 1 HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED DESIGN, ANO FIND IT TO BE IN COMPLIANCE WITH SECTION R301 OF THE FLORIDA BUILDING CODE, RESIDENTIAL 6TH EDITION (2017). THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUF. LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER. SEALED FOR STRUCTURE ONLY W 0 Q O V) 000 258241 • TITLE • MAIN FLOOR PLAN NOTING STAIR SECTION DETAILS • SHEET • 651-411 b- 61 T- as 0 36'4' REFER TO SHEET 2AI FOR MAIN FLOOR PLAN NOTES r 6 co e Y;w Io? Z 0 1 •(�+ 'roe.®'��;,� ...� • • ` ``�e�® MAIN FLOOR PLAN DIMENSIONS GARAGE RIGHT • • x ro 0 J 0� O O Jtnl�� v, I OM N 6 oj� o 00 0�� E5% 0_J Co E �0roN 00 ■ T O Z NG 1 • • JOB NUMBER 3-1812154• CAD FILE NAME LOT 281 BASE 01-04-18 ISSUED 04-30-18 DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OUXMAR., MOMA 34677 813, 925.1300 TEL 813.925.1800 FAX W W W DAVISBEWS,COM TAMPA • 1D0,4VER. EST. 1994 F— r,l 111 Ill VORTEX ENGINEERING, LLC. 607 S. ALEXANDER ST., SUITE 103 PLANT CITY, FLORIDA 33563 813.704.4842 COA 28035 PAUL D. KIDWELL, P.E. #52683 ANDREW J. MEISHEID, P.E. #83217 1 HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED DESIGN, AND FIND IT TO BE IN COMPLIANCE WITH SECTION R301 OF THE FLORIDA BUILDING CODE, RESIDENTIAL 6TH EDITION (2017). THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUF. LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER. SEALED FOR STRUCTURE ONLY W O 0 O V) pmmm4 0 Foam 1 000 >= _< vo 2582 , • TI TLE • MAIN FLOOR PLAN DIMENSIONS 2A2 TYPICAL WOOD FRAME WINDOW SCHEDULE WINDOW WIDTHS �C 2011 2411 3611 48° I WINDOW CALL -OUTS r .1� 0 20" I818 F.G. 2018 F.G. 3018 F.G. 406 F.G. W = 24" IKO F.G. 2020 F.G. 3020 F.G. 4020 F.G. J 0 36" 1,530 5H 2030 5H 3030 5H 4030 5H Z 45" 0 1840 5H 2O40 5H 3040 5H 4040 5H z 6011 650 5H 2O50 5H 3050 5H 4050 5H 1211 1860 5H 2O675H3060 5H 4060 5H G.C. VERIFY ROUGH OPENING5 FOR ALL WINDOW5, � u WINDOW 5IZE5 AND IN5TAI.UATION MAY VARY PER 8 MANUFACTURER AND 5PECIFICATION5, Z REFER TO FLOOR PI-AN5 FOR 5TYUE OF WINDOW U5ED (61NGLE HUNG-5H, CA5EMENT- C5MT, OR FIXED GLA55- F.G.) ALL EMERGENCY ESGAPE AND RE5GUE OPENING5 5HALL COMPLY WITH R310 PER F.B.C.R. - 6TH EDITION (2011). REFER TO SHEET 252 FOR UPPER FLOOR 2x 2x4 PLAN DIMEN51ON5 1' 0" FRAMEFRAME FRAME 91-00 X/ WALL WALL 2 - 3050 SH, HD. AT T-8" O c GD-1 FLUSH FRAME TO FURRING G.C. VERIFY ELECTRICAL BELOW AND BLOCKING REQUIREMENT5 AND I WEIGHTS FOR PLASMA TV. �T� LOFT BEDROOM 3 Q lO OPEN TO 11'-0"x14'-4" 9'-0" FLAT CLG, 12'-6"xl1'-0" 9'-0" FLAT CLG. BELOW X I 1� 2x4 FLU5W FRAME 42" H. 42" H. FRAME WALL TO FURRING RAILING RAILING CLG, CLG, ? a I GHAS BELOW 36 W. 24" N. METAL (0�DR CLG. � RAILING STAND - — — — — — R/5 2-6x6-8 DO 2-4x6-8 [NEWEL — — 9 -0 � 5x R/S — — 6-0x6-8 51-PA55 CLG. LN0.2 «� ILJ P05T 5-Oxb-8 Q i r- — -i 42" H. 2-64-8 PROVIDE 5I-PA55 Via' I I u RAILING PAN AND DRAIN I � 91-011 UNDER A.H.U. L— J 2-8xb-8 CLG. BEDROOM 2 B LOUVER DR. Nil BEDROOM 4 13'-4"x12'-8° ""' 9'-0" FLAT CLG.13'-6"x11'-0" LAV. WG BATH «� 9 —0 FLAT CLG. — 9' 011 M.C. �'- n BATH 2 �' o I A.N. CPT. TILE NO, I 2-6x6-8 CLG,Ix LAV. 2030 TEMP. 5W. PROVIDE 2411 W. METAL 3050 5H, THI), AT T4' PAN AND DRAIN STAND -1 HD. AT 1'-811 UNDER A.N.U. EGRE55 C9 r., o --------------------------- a i I i I I a I REFER TO 5HEET 252 FOR UPPER FLOOR — PLAN DIMEN51ON5 i I AA 3 UPPER FLOOR STRUCTURAL. LEGEND O - PROVIDE (3) 2x4 5TUD5 W/ (1) 51MP50N HTT4 CONNECTOR5 AT BASE. ® - PROVIDE (3) 2x8 5TUD5 W/ (1) 51MPSON HTT4 CONNECTORS AT BA5E. ® - PROVIDE 2-PLY 1.15" x 12" LVL BEAM NAILED TOGETHER W/ (2) ROWS OF 16d NAILS AT 12" O.C. FROM EACH FACE, ANCHORED TO DOUBLE JACK-5TUD5 AT EACH END WITH (2) 51MP50N M5TA30 STRAPS. 10 - PROVIDE 2-PLY 2x12 NO.2 5YP BEAM W/ 1/2" 056 FLITCH PLATE TIED TO DOUBLE JACK-5TUD5 AT EACH END WITH (1) SIMP50N L5TA12 STRAP. STRUCTURAL NOTES 6 ALL LVL'5 TO BE Fb=2950 P51 MIN. ALL WOOD LOAD BEARING HEADERS TO BE (2) 26 02 5YP UN.O. • ALL EXTERIOR WALL5 TO BE CON5IDERED 5HEAR RE515TING COMPONENT5 • NOT A SPECIAL FLOOD HAZARD AREA 10 NOTE: ROOF LINE5 CHANGE W/ ALT. ELEVATION5, REFER TO ROOF PLAN5 ON SHEET$ 35, 3C, 33, 3E, AND 3F FOR CORRESPONDING ROOF LINE5. WINDOW FALL. PROTECTION �Cc IN DWELLING UNIT5, WHERE THE OPENING OF AN OPERABLE WINDOW 15 LOCATED MORE THAN 12 INCHE5 ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW 5HALL BE A MINIMUM OF 24 INCHE5 ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW 15 LOCATED. OPERABLE 6ECTION5 OF WINDOWS 5HALL NOT PERMIT OPENING5 THAT ALLOW PA55AGE OF A 4 INCH DIAMETER 5PHERE WHERE 5UGW OPENINGS ARE LOCATED WITHIN 24 INCHE5 OF THE FINI5HED FLOOR PER F.B.C.R. - 6TH EDITION (2011) R3122 WINDOW FALL PREVENTION DEVICES AND WINDOW GUARD5, WHERE PROVIDED, 5HALL COMPLY WITH THE REQUIREMENT5 OF A5TM F 2090 PER F.B.CR - 6TH EDITION (2011) R3122 UPPER FLOOR PLAN NOTES. GARAGE RIGHT x ro Lo r O o lQ O JccoI�� I �N�M Lo N LL" `/i 0 rr 03 Cp LLY %4� J y ooc0ti T ZNGd' • JOB NUMBER B-1812154 • CAD FILE NAME LOT 281 BASE 01-04-18 ISSUED 04-30-18 91 DAMS BEWS DESIGN GROVP 150 STATE STR.EEC EAST OLDWAR, FLORIDA W77 813.925.1300 TEL 813. 925, 1800 FAX W W W DAVlSBEWS.COM TAMPA • DE 4\ ERZ EST. 1994 o� Ili ILI VORTEX ENGINEERING, LLC. 607 S. ALEXANDER ST., SUITE 103 PLANT CITY, FLORIDA 33563 813, 704.4842 COA 28035 2 1 PAUL D. KIDWELL, P.E. ##52683 ANDREW J. MEISHEID, P.E. 483217 I HEREBY CERTIFY THAT WAVE REVIEWEDTHE ATTACHED DESIGN, AND FIND IT TO BE IN COMPLIANCE WITH SECTION R301 OF THE FLORIDA BUILDING CODE, RESIDENTIAL 6TH EDITION (2017), THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUR LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION 15 SUPPLIED TO THE ENGINEER. SEALED FOR STRUCTURE ONLY 0 0 00 c)�\ � V 2582 • TI TLE • UPPER FLOOR PLAN NOTES DETAILS • SWEET • III REFER TO SHEET 251 FOR UPPER FLOOR PLAN NOTES `0%111111111 / `� eeee•eo f' w s . 111 • o Z O 0 ®ev ., 0D 1 C ,• �o,►rrlle�e NOTE: ROOF LINES CHANGE V ALT. ELEVATION5, REFER TO ROOF PLAN5 ON 5HEET5 35, 3C, 31), 3E, AND 3F FOR CORRESPONDING ROOF LINES. * * * * * * * * K m CQ0Q In p,JMI,�, VI 0 0) cf) N " > > J N V ` co °°�' • p 0 -0r, p J C o IL Y OW LJ.-0 `a o y� T Z N 2 a • • JOB NUMBER B-1812154' CAD FILE NAME LOT 281 BASE 01- 04-18 ISSUED 04-30-18 DAVIS BEWS DESIGN GROUP 150 STATE STREET EAST OLDSMAR, RX)MA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TA vlPA • E>EIVVER. -_� EST. 1994 VORTEX ENGINEERING, I.I.C. 607 S. ALEXANDER ST., SUITE 103 PLANT CITY, FLORIDA 33563 $13.704.4842 COA 28035 ' PAUL D. KIDWELL, P.E. #52683 ANDREW J. MEISHEID, P.E. #83217 I HEREBY CERTIFY THAT I HAVE REVIEWEDTHE ATTACHED DESIGN, AND FIND IT TO BE INCOMPLIANCE WITH SECTION R301 OF THE FLORIDA BUILDING CODE, RESIDENTIAL GTH EDITION (2017). THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUF. LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER. SEALED FOR STRUCTURE ONLY C a m 0 (of) pmmq o a N ..J Q �=C 2582 , • TITLE • UPPER FLOOR PLAN. DIMENSIONS SHEET UPPER FLOOR PLAN DIMENSIONS o)po) 6CALE: 1/4" : 141" GARAGE RIGHT • • NJ i.!I, �, II LANAI ROOF VENT REQUIREMENTS -------------------- -------------- - VENTILATION CALCULATIONS ATTIC AREA =139 SQ. FT. / 300 = 0.46 SQ. FT. X 144 = 67 SQ. IN. 4:12- I HALF AT UPPER 2/3 ROOF VENTS = 33.36 SQ. IN. I I I # UPPER 2/3 ROOF VENTS REQUIRED =1 I 6:12 I —► - - - - - - - - - - - - - - - HALF AT LOW SOFFIT/ EAVE VENTS = 33.36 SQ. IN. I 6:12 I ACTUAL SOFFIT VENTILATION =124.8 SQ. IN. I I I I I � I I I 4R I I I y� I I I I I I I UPPER ROOF i VENT REQUIREMENTS VENTILATION CALCULATIONS I ATTIC AREA =1464 SQ. FT. / 300 = 4.88 SQ. FT, I Lu I X 144 = 703 SQ, IN. 6:12 rx 6:12 HALF AT UPPER 2/3 ROOF VENTS = 351.36 SQ. IN. I # UPPER 2/3 ROOF VENTS REQUIRED = 3 I HALF AT LOW SOFFIT / EAVE VENTS = 351.36 SQ. IN. i i I i I ACTUAL SOFFIT VENTILATION = 877.1 SQ, IN. I I I w I I i I 6:12 I �1 I 1 I I ------�\--------- 1 I I I 6:12 LOWER ROOF VENT REQUIREMENTS r I j VENTILATION CALCULATIONS - i - - - - - - - 6:12 6_I2 ATTIC AREA = 529 SQ. FT. / 300 =1.76 SQ. FT. I I X 144 = 254 SQ. IN. O 1 i TYP I I HALF AT UPPER 2/3 ROOF VENTS=126.96 SQ. IN. OVERHANG # UPPER 2/3 ROOF VENTS REQUIRED =1 AT HIP (UN.D.) I �e yA I HALF AT LOW SOFFIT / EAVE VENTS=126.96 SQ. IN. ACTUAL SOFFIT VENTILATION = 381.3 SQ. IN, ROOF PLAN AA SCALE: I/811 : I' -Oil 11/2" THICK SAND FIN15H KEYSTONE (IF APPLICABLE) RAISED SAND FIN15H �- TEXTURED BANDING 3/411 1 " THICK NOTE: THIS DETAIL SHOWS THE TYPICAL THICKNE55 OF ALL RA15ED TEXTURED FINISH BANDING AND SAND FINISHED KEYSTONES (WHERE APPLICABLE) IF THICKNE55 15 TO BE DIFFERENT IT WILL BE CALLED OUT AT SPECIFIC KEYNOTE CALL -OUT INSTALLATION OF EXTERIOR LATHING AND FRAMING APPLICATION REQUIREMENTS TO BE PER FB.CR - 6TH EDITION (2011) R103.1J AND ASTM C 1063. THICKNE55 OF TEXTURED FIN15H OVER FRAME APPLICATION TO BE PER F.B.C.R. - 6TH EDITION (2011) R103.12 AND ASTM C 926. TYP. CROSS-SECTION OF RAISED TEXTURED FINISH BANDING AND / OR SAND FINISH KEYSTONE SCALE: 3" , P-0' SHINGLE Q6 SHINGLE 6 12-SHINGLE ROOF PLT. HT. _ _ _ - _ PLT. HT. EITEMP,zL-5TUCCOSlUCCO «� FINISH? � � 12 FINISH, * ROOF 12 Q6 SHINGLE SECOND F.F. LINE SECOND F.F. LINE _ SECOND F.F. LINE _ 811 �6 ROOF _SECOND F`F. LINE T.O.M. T.O.M. _ ZTEXTURED - TEXTURED a, 6, FINISH? FINISH MAIN F,F. LINE _ _ _ _ - _ _ _ _ _ _ _ _ _UL,,,I- L_ _ /l _ MAIN F.F. LINE _ GRADE LINE Nw" GIM GRADE LINE (ASSUMED) Dwom (ASSUMED) LEFT ELEVATION SCALE: 1/6" : I'-011 GIRDER-,6 IL' TRU55 „� �c WINDOW FALL PROTECTION �c IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW 15 LOCATED MORE THAN 12 INCHES ABOVE THE FIN15HED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW 15 LOCATED. OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHES OF THE FIN15HED FLOOR PER F.B.C.R - 6TH EDITION (2011) R3122 WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS, WHERE PROVIDED, SHALL COMPLY WITH THE REQUIREMENTS OF A5TM F 2090 PER F.13L.R - 6TH EDITION (2011) R3122 6 12 12 /SHINGLE 12 Q6 ROOF 6� -'—SHINGLE PLT. HT._ ROOF PLT. HT. 5TUCGO /STUCCO FINISH �'- F.G. F.G. * FINISH% SECOND FF. LINE 412 SHINGLE 8' _SECOND F.F. LINE — "' T,O.M. ROOF-- T.OM. - C9 TEXTURED FINISH MAIN F�F. LINE _ TEXTURED ;? FIN15H FF. LINE _ GRADE LINE GRADE LINE (ASSUMED) (ASSUMED) REAR ELEVATION SCALE: 1/8" : I'-011 TEMP. b- GIRDER TRU55 12 SECTION AA SCALE: 1/5" : I'-011 �c EGRE55 NOTE: EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES WITH EGRE55 CODES, IF THERE 15 NO ACCE55 TO EXTERIOR THROUGH A DOOR,. THE WINDOW MUST HAVE A MAXIMUM OPENING HEIGHT OF 44" ABOVE FIN15H FLOOR LINE OF THAT PARTICULAR ROOM _ PLT. HT, 4" BANDING (TYP.) V-411 W. x 54" H ---- DECORATIVE FIXED SHUTTERS c!J 4" BANDING (TYP.) SECOND F.F. LINE T.O.M. — 811 BANDING -- 4" BANDING TEXTURED FIN15H 6 I� G,C, VERIFY ALUMINUM ovER 2x6 SUB-FA5CIA (TYPICAL) L STUCCO 29-1 1 1 j FINISH 6 ICi -SHINGLE 6 I�,- ROOF / BANDING MAIN FF. LINE a. - GRADE LINE 4" BANDING (ASSUMED) DOOR SURROUND NOTE: ALL BANDING 15 TO BE RAISED SAND FINISH CONC. LINTEL 0: z .•, s • � /SHINGLE 26 ROOF� 6 I� -SHINGLE RDOF PLT. HT. STUCCO 1'-4" W. x 54" H. DECORATIVE FIN15H� FIXED SHUTTERS cA �' �9 ep �12 N /SHINGLE a6 ROOF SECOND F.F. LINE co g 6" BANDING COACH LIGHT TEXTURED FIN15H BANDING _ MAIN F.F. LINE — TEMP 1717 F] [71 E] [71171 ❑�"�❑❑❑�❑❑ FRONT ELEVATION SCALE: 1/4" : 11-011 GRADE LINE (ASSUMED) 6 1� 126 /SHINGLE 12 6 12ROOF Q6 SHINGLE ROOF PLT. HT_ _ _ _ _ _ PLT. HT. •-STUCCO -STUCCO /6TUCCO 6 FINISH FINISH 7 SHINGLE 12 FINISH 12 /SHINGLE � 6' �l� �l � 4 �l SECOND F.F. LINE ROOFF7 all SECOND F.F. LINE ROOF $II SECOND F.F. LINE `A TOM,- — - T.O.M. ZTEXTUREID /TEXTURED -TEXTUREDTEXTURED 67 FINISH FIN15H �ro FINISH FINISH 7 �o MAIN FF. LINE _ _ �l _ _ _ _ _ _ _ _ _ �l _ _ _ �l MAIN F.F. LINE GRADE LINE GRADE LINE (ASSUMED) (A55UMED) RIGHT ELEVATION SCALE: /811 : I' -/?ill AL ELEVATION �AlTRADITION GARAGE RIGHT x ro U �o C oN _co - 0r I 2c'nm YI T L >>,JN L L oaU.. 0 0 -0 %` m FL E re m oolCCOr. ZcovLv • JOB NUMBER B-1812154� CAD FILE NAME LOT 281 BASE 01-04-18 ISSUED 04-JO-18 DAVIS BEWS DESIGN GROVP 150 STATE STREET FAST OLDSMAR, FLOR DA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.GOM TAMPA • E>ENVER EST.1994 F— �1-1�111 VORTEX ENGINEERING, LLC. 607 S. ALEXANDER ST., SUITE 103 PLANT CITY, FLORIDA 33563 813.704.4842 COA 28035 PAUL D, KIDWELL, P.E. #52683 ANDREW I. MEISHEID, P.E. #83217 1 HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED DESIGN, AND FIND IT TO BE IN COMPLIANCE WITH SECTION R301 OF THE FLORIDA BUILDING CODE, RESIDENTIAL 6TH EDITION (2017). THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUF. LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER, SEALED FOR STRUCTURE ONLY W O 0 0 a� Q a 0 ve 2582 , • PTLE • ELEVA TIONS ROOF PLAN BUILDING SECTION DETAILS • SHEET • � I I �n BUILDING WRAP TO GO OVER FLASHING FLASHING TO BE FLEXIBLE SELF ADHESIVE TYPE (MIN 6" WIDE) PRECAST LINTEL TYPICAL FLASHING AT PRECAST AND EXTERIOR SHEATHING F MATERIAL PER VATIONS WITH APPROVED )ERLAYMENT (REFER TO /ER SHEET) !-ENGINEERED ROOF ISSES AT 24" O.C. ,RICANE STRAP PER )F FRAMING PLAN gk BRG. HGT. 1M. DRIP EDGE FASCIA JTED ALUM. SOFFIT =ATH & EXT. FINISH JDOW FLASHING AS REQ'D WINDOW TRIM kDER TYPICAL WINDOW AND SLIDING GLASS DOOR" ' FLASHING DETAIL OPTION - A FLASHING WOODEN SIDING SILL PLATE SEE NOTE #2 WALL SHEATHING NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW SILL PLATE 3. INSTALL SILL FLASHING AS SHOWN ABOVE 4. INSTALL FLASHING AROUND REMAINING WINDOW UNIT 5. WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS TYPICAL FLASHING DETAIL AT SILL PLATE. TIE-IN WITH WEATHER RESISTIVE BARRIER: 1. INTEGRATE INSTALLATION OF WEATHER RESISTIVE BARRIER WITH FLASHING TO FORM WATER SHEDDING LAPS 2. SCORE & FOLD WEATHER RESISTIVE BARRIER ABOVE HEADER TO ALLOW FOR FLASHING INSTALLATION 4. INSTALL HEAD FLASHING UNDER WEATHER RESISTIVE BARRIER 5. FOLD WEATHER RESISTIVE BARRIER BACK OVER HEAD FLASHING AND SEAL WITH WEATHER RESISTIVE BARRIER TAPE FLASHING PROVIDE SELF ADHERED Z FLASHING UNDER S.G.D. AS SHOWN, PROVIDE 4" -1'" BEAD OF CONST. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WATER PROOF CAULKING i PROVIDE SELF ADHERED FLASHING LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6" 15/32 O.S.B. SHEATHING BUILDING WRAP BEYOND 147 RUBBER MEMBRANE BEYOND CAULK/SEALANT OR SOLDER BETWEEN PAN FLASHING AND DECK FLASHING. L ' EXTERIOR FINISH PER BUILDER -7 WATERPROOF MEMBRANE 2X12 #2 SYP CONT LEDGER W/ (4) 1/4" X 4" LAG SCREWS SPACED EVENLY @ 24" O.C. MAX ( EA. FLOOR TRUSS) USP HTA20 STRAP EA. JOIST TEXTURED CEMENT PLASTER FINISH TYPICAL DOOR FLASHING AT BALCONY EXTERIOR SHEATHING ��T�c�,� FOLD UP WEATHER RESISTIVE BARRIER & TEMPORARILY SECURE RFs�sr Ol yJ�P WEATHER RESISTIVE BARRIER APR- SILL PLATE (SEE DETAIL B O 2 FOR OPTIONS) 0�'EZ CORNER PATCH FLASHING NOTES: 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) 2. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS 3. MECHANICALLY FASTEN AS NECESSARY TYPICAL SLIDING GLASS DOOR FLASHING DETAIL FOLD UP WEATHER RESISTIVE MECHANICALLY FASTEN AS WEATHER BARRIER & TEMPORARILY SECURE NECESSARY IN CORNERS RESISTIVE THROUGH FLASHING . BARRIER i WEATHER / EXTERIOR RESISTIVE SHEATHING BARRIER TAPE / SILL PLATE (ASSEMBLED WINDOW) FLASHING HEAD FLASHING TIE-IN INSTRUCTIONS: 2 1 FLASHING � 2 / FLASHING DO NOT FLASH OVER BOTTOM NAILING FLANGE NOTES: 1. CUT, FOLD UP & TEMPORARILY SECURE WEATHER RESISTIVE 1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) BARRIER ABOVE HEADER TO ALLOW FOR FLASHING 2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW INSTALLATION SILL PLATE 2. INSTALL HEAD FLASHING UNDER 3. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS WEATHER RESISTIVE BARRIER 4. INSTALL FLASHING AND WEATHER RESISTIVE 3. FOLD WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS BARRIER BACK OVER HEAD FLASHING AND SEAL WITH TAPE TYPICAL WINDOW FLASHING DETAIL NOTE: SEE STRUCTURAL SHEETS FOR INFORMATION NOT SHOWN. PROVIDE SELF ADHERED FLASHING LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6" 2X EXT WALL FLASHING TO EXTEND 36" SHEATHING W/ BUILDING WRAP BEYOND FLASHING. STUCCO STOP WATERPROOF MEMBRANE SEE STRUCTURAL FOR CONNECTORS FLOOR TRUSS SEE STRUCTURAL 8' CMU BLOCK SEE STRUCTURAL TYPICAL FLASHING AT BALCONY EXTERIOR FINISH PER BUILDER PROVIDE FLASHING BOOT AT POSTS WATERPROOF MEMBRANE FLOOR SHEATHING FLASHING. 2X8 TRIM BOARD STUCCO "J" MOLD SHEATHING TEXTURED CEMENT PLASTER FINISH WALL COVERING 2017 FBCR SECTION R703 EXTERIOR COVERING EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE EXTERIOR VENEER AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO THE EXTERIOR WATER THAT ENTERS THE ASSEMBLY. PROTECTION AGAINST CONDENSATION IN THE EXTERIOR WALL ASSEMBLY SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R702.7 OF THE CODE. R703.2 WATER -RESISTIVE BARRIER ONE LAYER OF APPROVED WEATHER -RESISTANT MATERIAL, FREE FROM HOLES AND BREAKS, COMPLYING WITH ASTM D 226 FOR TYPE 1 APPROVED WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SUCH MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, MATERIAL SHALL BE LAPPED NOT LESS THAN 6 INCHES (152 MM). THE APPROVED MATERIAL SHALL BE CONTINUOUS TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED IN SECTION R703.1. R703.4 FLASHING APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, ASTM C1281, AAMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT DRAINAGE, MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING OR OTHER APPROVED METHOD: 1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOWS AND DOOR OPENINGS, PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL ALSO INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES. 1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL. 1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS. 1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA 250, FMA/AAMA/WDMA 300, OR FMA/AAMA/WDMA 400. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. 7. AT BUILT-IN GUTTERS. FLASHING DETAILS x 2 C r0 0 j Lo OJMI��. 2 j > J N L oolL • O ro` ti 0 �= 0 0-� �O E5% E ILY l�o C4 L J 0 0020 z cli F27002,000 ME FL 01-05-18 DAVIS BEWS DESIGN GROUP 150 STATE STREET EAST OUXWAR, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVLSBEWS.COM TAMF'A • IJENVER EST. 1994 • TITLE • FLASHING DETAILS • SHEET • SHEATHING TEXTURE FINISH COAT BROWN COAT SCRATCH COAT SELF -FURRING LATH TWO LAYERS WRB WEEP SCREED TERMINATE SELF ADHESIVE FLASHING AT LOWER NOSE OF M.W.W.S. SELF ADHESIVE FLASHING MASONRY BLOCK WALL WEEP SCREED AT MID -WALL MASONRY TO WOOD DETAIL WOOD FRAME CONSTR. SELF -ADHERED FLASHING BY LAPPING DOWN OVER RIM JOIST AND UP WALL BY 6 IN. SEAL TOPS OF--- -__- JOISTS UNDER DECKING (SEE DETAIL WP07) WEATHER RESISTIVE BARRIER DOOR ROUGH OPENING 3/4"-1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN UP JAMB 6". USE LIQUID NAIL BRAND „ OR EQUAL WEATHER PROOF y t CAULKING SELF -ADHERED FLASHING "9YM9., m11Ne(111dWk(4 klC M l MM4 � i v SUBFLOOR RIM JOIST SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK - SECTION A EXTERIOR -- WINDOW UNIT SLOPE 0.3 in: 12.0 in (0.6 cm: 30.5 cm) SELF -ADHERED FLASHING EXTERIOR CEMT. FIN. BUILDING PAPER WIRE LATH 7771 � m SELF -ADHERED FLASHING CEMT. FINISH SILL/ POTSHELF/CHIMNEY SHOULDER SHEATHING MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT - EXTERIOR SHEATHING �� 3/4"A" BEAD OF CONSTR. ADHESIVE TO INSTALL SELF -ADHERED NEEDED IN CORNERS ADHESIVE ASPHALT ADHESIVE BE APPLIED UNDER THRESHOLD OF FLASHING JAMB &HEAD THROUGH SELF -ADHERED DOOR AND RETURN UP JAMB 6". USE FLASHING, SEE FLASHING SELF -ADHERED FLASHING LIQUID NAIL BRAND OR EQUAL FLANGED WINDOW (SEE 9i IiiV REFER TO TECHNICAL / / WEATHER PROOF CAULKING DETAIL WP01) SCORED LETTER ON CHEMICAL ' NP RELEASE PAPER COMPATIBILITY SELF -ADHERED FLASHING SELF -ADHERED FLASHING, (BEFORE FOLDING, SCORE EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE VERTICALLY FROM ADHESIVE AS SHOWN) BOTTOM OF THRESHOLD SECTION -A (SEE ° DETAIL WP02) SELF -ADHERED FLASHINGol 'U \ / SELF -ADHERED" NAILING FLANGE FLASHING DO NOT FLASH OVER BOTTOM NAILING FLANGE / SEAL TOPS OF JOISTS UNDER DECKING (SEE DETAIL WP07) *INSTALL SELF -ADHERED FLASHING IN ORDER AS SHOWN BY NUMBERS ** INSTALL FLASHING AND WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS SELF -ADHERED FLASHING SELF -ADHERED FLASHING SELF -ADHERED FLASHING HALF ROUND WINDOW EXTERIOR DOOR WITH DECK INSIDE CORNER WALL SHEATHING % ASPHALT SEALANT:j�jj CONT. GALV. "L" EXTEND MIN. OF 6" �j FLASHING PER TEXTURED, PAID OUTSIDE OF FLASHING j MANUFACTURES EXTER. WALL FI SPECIFICATIONS ROOF CRICKET: MIN: 3:12 SLOPE PLASTER STOP j CRICKET AS (REQUIRED AT SPECIFIED ALL LEVEL VALLEY VERTICAL WALL BEAUTY STRIP I BY PLAN LOCATIONS) AT ENTRY SHINGLE OVER 6„ j :;':;:•:,, :,.., FLASHING W/TE CONT. GALV. "L' FLASHING PER DIVERTER AI FLASHING M/' V61, DRIP EDGE FASCIA FIGURE 1: FLASHING INSTALLATION TEXTURED, PAINTED EXTERIOR WALL FINISH r?"'" ?° `;v : :` : °` HOLD EXTERIOR :;� : ° FINISH 2" ABOVE IN ROOF a ` ` o A a`' ,` '`, FLASHING CAULKING FIGURE 2: WALL FINISH ASPHALT SEALANT: EXTEND MIN. 6" ABOVE FLASHING 6 TO 12" PER PLAN SPECS. 6" HIGH DIVERTER FLASHING GALV. 'L' FLASHING TYPICAL. ROOFING FELT '! -DRIP EDGE FASCIA FIGURE 3: CORNER DETAIL MANUFACTURES / SPECIFICATIONS OVER ROOF ROOF (MATERIAL PER SHINGLES W/ TAR ELEVATIONS WITH APPROVED NOTE: THIS DETAIL IS REQUIRED UNDERLAYMENT (REFER TO AT ALL VERTICAL WALL INTERSECTIONS COVER SHEET) WITH ROOF VALLEYS & ROOF CRICKETS. PRE-ENGINEERED ROOF TRUSSES AT 24" O.C. BEAUTY STRIP ROOF SHINGLE OVER ASPHALT BASED SEALANT APPLIED BEHIND FLASHING AND EXTENDING A MINIMUM OF 6" ABOVE VERTICAL RISE OF FLASHING AT KNEEWALL SEALANT HING DETAILS FLASHING W/ TAR FLASHING INSTALLATION CONT. GALV. "L" WHERE ROOF MEETS VERTICAL WALL FLASHING PER MANUFACTURES SPECIFICATIONS OVER ROOF SHINGLES W/ TAR SHINGLE PER CONTRACT Rya METAL DRIP EDGE TO 9�Ys, r BE UNDER TyyFq y UNDERLAYMENT AT F9 ' 9C+ �''< ROOF EAVES q_/ OHO/�O SSOy tic �'`1< syq R°°F ae°y` �y9iy �L,A 2, S�oE� C o�R�yM�Ns �No�PP TYPICAL ROOF TO O o A WALL FLASHING DETAIL Fq�TtiTo� 5�N°°U�al °°��S� NOC 01's \° g� % 1st° RAKE METAL DRIP EDGE s' „ LINE VALLEY BY CENTERING 36" WIDE TO BE OVER 2 EAVESUNDERLAYMENT AT 14" CERTAINTEED WINTERGUARD GABLE ENDS FIRST STARTER SHINGLE WATERPROOFING SHINGLE 7' UNDERLAYMENT OR EQUIVALENT EXTEND THE SHINGLES OVER DIRECTLY TO DECK. THE RAKE AND EAVES ABOUT SAVE 7" PIECES 1/2" IF DRIP EDGE IS USED, OR TO USE IN 5TH ABOUT 3/4" IF NO DRIP EDGE IS COURSE USED. EMBED EACH SHINGLE IN A 2" DO NOT NAIL WITHIN 6" WIDE STRIP OF ASPHALT VALLEY CENTERLINE RAGING CEMENT. CUT 2" DIAGONALLY OFF UPPER CORNER OF TRIMMED SHINGLE CUT SHINGLES 2" BACK FROM VALLEY CENTERLINE REMOVE -J FIGURE 4: VALLEY DETAIL CEMENT PLASTER IN — ACCORDANCE WITH ASTMC926 OVER WOOD 2ND FLOOR / CEMENT PLASTER OVER BLOCK 1ST FLOOR NOTE: �\ THE BUILDING PAPER AND METAL LATH MUST BE INSTALLED OVER THE TOP OF THE WEEP SCREED. 7/8" CEMENT PLASTER IN ACCORDANCE WITH ASTMC926 APPROVED WEATHER -RESISTANT MATERIAL W/ METAL LATH IN ACCORDANCE WITH ASTMC1063 BUILDING PAPER 7/16" O.S.B. SHEATHING METAL FLASHING 3 1/2" UNPERFORATED FLANGE 7/8" WEEP SCREED MAINTAIN BOTTOM OF WEEP SCREED 1 1/2" TO 2" ABOVE ROOF SHEATHING SLAB OPTIONAL DETAIL WEEP SCREED DETAIL SCALE: NOT TO SCALE 7/8" CEMENT PLASTER IN ACCORDANCE WITH ASTMC926 APPROVED WEATHER -RESISTANT MATERIAL W/ METAL LATH IN ACCORDANCE WITH ASTMC1063 BUILDING PAPER 7/16" O.S.B. SHEATHING KEEP TOP EDGE OF WEEP SCREED 2" BELOW TOP OF BLOCK VULCUM CAULK BOTTOM JOINT ONLY METAL FLASHING 3-1/2" UNPERFORATED FLANGE 7/8" WEEP SCREED 1/2" CEMENTITIOUS DECORATIVE FINISH ALL INSIDE AND OUTSIDE CORNER WILL NEED TO BE MITER CUT AND CAULKED ALL BUTT JOINTS NEED TO BE EMBEDDEDIN SEALANT USING VULCUM CAULK FOR ALL 1/2" CEMENT PLASTER FINISH 2 1/2" PERFORATED FLANGE 1/2" WEEP SCREED INSTALL BOTTOM EDGE OF WEEP SCREED 1" BELOW FINISH FLOOR SELF -ADHERED - FLASHING PATCH kDHERED FLASHING THESE DETAILS ARE GENERIC AND MEANT FLASHING DETAILS TO SHOW GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. N.T.S. • x ro C r0 J O_IMI`��, Lo 0 M m N �. OaLL 00 0-� rO �� �� i J ppCltfh Z_ • JOB NUMBER 27002, 000 • CAD FILE NAME FL ISSUED 01-05-18 REVISED C.,.- I rc� t6- DAVIS BEWS DESIGN GROUP 150 STATE STREET EAST OUWAAR, FLORMA 34677 813.925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TAMPA • DENVER. EST. 1994 F-: , rnwnronwiunun��wwn�wwaw.�w�nwmnw�uuww�.�r • TITLE • FLASHING DETAILS LECTfRICAL <E'�- DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER K.P. WEATHERPROOF DUPLEX OUTLET KN.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH 13 THREE-WAY SWITCH 14 FOUR-WAY SWITCH $ D DIMMER SWITCH CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE Ac LIGHT FIXTURE WITH PULL CHAIN 4— TRACK LIGHT FLUORESCENT LIGHT FIXTURE f� EXHAUST FAN Q, EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) ® CHIMES (OPTIONAL) Ei PUSHBUTTON SWITCH (OPTIONAL) © CARBON MONOXIDE DETECTOR @ SMOKE DETECTOR (ARC -FAULT) so SMOKE / CARBON MONO. COMBO DETECTOR (ARC -FAULT) I Q TELEPHONE (OPTIONAL) M TELEVISION (OPTIONAL) UT THERMOSTAT �p ELECTRIC METER *w ELECTRIC PANEL DISCONNECT SWITCH ® SPEAKER (OPTIONAL) c� ROUGH -IN FOR OPT, CEILING FAN V J c� CEILING MOUNTED INCANDESCENT LIGHT FIXTURE W/ G J ROUGH -IN FOR OPT. CEILING FAN NOTES- 1. PROVIDE AND INSTALL GROW FAULT CIRCUIT -INTERRUPTS IGF.IJ AS INDICATED ON PLANS OR AS ITEM NO.4 AND 5 BELOW INDICATES. 2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISHED FLOOR: SWITCHES.... 42" OUTLETS ..... 14" TELEPHONE. ,14" (UNLESS ABY COUNTERTOP) TELEVISION...14" 3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS. 4. ALL 15A AND 20A RECEPTACLES IN KITCHENS, SLEEPING ROOMS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ALAS WILL REQUIRE A COMBINATION TYPE AF.C.I. DEVICE AND TAMPER -PROOF RECEPTACLES PER NE.C. 2014 406.12 AND 406.13 5. ALL 15A AND 20A 120Y RECEPTACLES LOCATED IN THE GARAGE AND UTILITY ROOMS SHALL BE GF.C.I. PROTECTED (GRI). 6. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO ENSURE THAT ALL ELECTRICAL WORK IS IN FULL COMPLIANCE WITH NF.PA 10, NE.C. 2014, F.B.C.R - 6TH EDITION (2011), AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES. 1. EVERY BUILDING HAVING A FOSSIL -FUEL -BURNING HEATER OR APPLIANCE, FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL CARBON MONOXIDE DETECTOR INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES. 8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACKUP. COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED OR LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY, W.P. GF.I. A/C DISCONN. ----�FE i I._.---J I W.P. GF.I. A/C DISCONJ, G.C. VERIFY ELECTRICAL AND BLOCKING REQUIREMENTS AND HEIGHTS FOR PLASMA TV. MAIN DISCONNECT (METER COMBO - SQUARE D REFER TO FLOOR PLAN FOR NOTED MAIN DISC. AMPS. REQUIRED UNDERGROUND SERVICE BY POWER COMPANY WIN WN DIRECT VENT THRU EXT. WALL 4/0 ALU. CABLE A/C DISC. TYP. 14 AND M2 COPPER TO INSIDE LIGHTS AND OUTLETS PANEL 10 COPPER TO WATER HEATER 118 COPPER TO RANGE 04 COPPER TO 5/8" GROUND ROD ALSO SERVICE TO BE BONDED TO FOOTING STEEL ELECTRICAL RISER DIAGRAM NOTE: ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS OF THE NATIONAL ELEC. CODE, LOCAL CODES, AND THE LOCAL POWER COMPANY. G.C. VERIFY UNDER CABINET LIGHTING AT KITCHEN MICROWAVE VENT HOOD AND 1711TI FT 41A"— MICRO TO EXTERIOR W.P. GF.I. FOR TU6. 111. COACH LIGHT G.C. VERIFY ALL SMOKE DETECTORS TO BE HARD -WILD * * * COACH LIGHT G.C. VERIFY PERSONALIZED HOME TECHNOLOGY • x ca w C 100 J,�O .j co N - N CO ocoo(�co r— .N co Lm > > J N p0-LL Z r j C°p E0 04 4 - � 6. C n ZN4d • JOB NUMBER B-1812154• CAD FILE NAME LOT 281 BASE 01- 04-18 ISSUED 04-30-18 DAVIS BEWS DESIGN GPOVP 150 STATE STREET EAST OLDWA , FLORMA 34677 813. 925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM TAMPA • E>ENVER. -� EST. 1994 - W Y O O �z O v) O11=0004 = oc �- o 000 N J Fmml >01", 0 _< 2582 • TITLE • MAIN FLOOR ELEC. PLAN • • MAIN FLOOR ELECTRICAL PLAN SHEET 4A . GARAGE RIGHT EL CTFIl. AL 11.,E DUPLEX CONVENIENCE OUTLET DUPLEX OUTLET ABOVE COUNTER P WEATHERPROOF DUPLEX OUTLET F GROW FAULT INTERRUPTER DUPLEX OUTLET HALF -SWITCHED DUPLEX OUTLET SPECIAL PURPOSE OUTLET DUPLEX OUTLET IN FLOOR 220 VOLT OUTLET WALL SWITCH 13 THREE-WAY SWITCH 14 FOUR-WAY SWITCH $ D DIMMER SWITCH -� CEILING MOUNTED INCANDESCENT LIGHT FIXTURE WALL MOUNTED INCANDESCENT LIGHT FIXTURE i0 RECESSED INCANDESCENT LIGHT FIXTURE -4c LIGHT FIXTURE WITH PULL CHAIN TRACK LIGHT FLUORESCENT LIGHT FIXTURE Cj EXHAUST FAN iJ EXHAUST FAN/LIGHT COMBINATION ELECTRIC DOOR OPERATOR (OPTIONAL) ® CHIMES (OPTIMAL) p PUSHBUTTON SWITCH (OPTIONAL) CARBON MONOXIDE DETECTOR so SMOKE DETECTOR (ARC -FAULT) so SMOKE / CARBON MONO. COMBO DETECTOR (ARC -FAULT) TELEPHONE (OPTIONAL) M TELEVISION (OPTIONAL) (r THERMOSTAT (p ELECTRIC METER s ELECTRIC PANEL DISCONNECT SWITCH ® SPEAKER (OPTIONAL.) �7 ROUGH -IN FOR OPT. CEILING PAN v J c� CEILING MOUNTED INCANDESCENT LIGHT FIXTURE W/ G J ROUGH -IN FOR OPT, CEILING PAN NOTES - I. PROVIDE AND INSTALL GROUND FAULT CIRCUIT -INTER PTERS (G,F.I) A$ INDICATED ON PLANS OR AS ITEM NO.4 AND 5 BELOW INDICATES. 2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISHED FLOOR: SWITCHES.... 42" OUTLETS ..... 14" TELEPHONE...14" (UNLESS ABV COUNTERTOP) TELEVISION...14" 3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP, PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS. 4. ALL 15A AND 20A RECEPTACLES IN KITCHENS, SLEEPING ROOMS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND SIMILAR ALAS WILL REQUIRE A COMBINATION TYPE AF.C.I. DEVICE AND TAMPER -PROOF RECEPTACLES PER N.E.C. 2014 406.12 AND 406.13 5. ALL 15A AND 20A 120V RECEPTACLES LOCATED IN THE GARAGE AND UTILITY ROOMS SHALL BE GF.C.I. PROTECTED (G.F.U. 6. IT 15 THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO ENSURE THAT ALL ELECTRICAL WORK IS IN FULL COMPLIANCE WITH NF.P.A.10, N.E.C. 2014, F.B.C.R - 6TH EDITION (2011), AND ALL APPLICABLE LOCAL STANDARDS, CODES, AND ORDINANCES, 1. EVERY BUILDING HAVING A FOSSIL -FUEL -BURNING HEATER OR APPLIANCE, FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL CARBON MONOXIDE DETECTOR INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES, S. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING 15 SERVED FROM THE LOCAL POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACKUP. COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED OR LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. II 111V MAKE-UP LIGHT UPPER FLOOR ELECTRICAL PLAN. GARAGE RIGHT •Ic K c� to 0 JLNO OJc`nl�0) to 0co i. .23s > j_JN 00 a85-� 0� �o E=m � rn C'A 00 ZN d' • JOB NUMBER B-1812154• CAD FILE NAME LOT 281 BASE 01— 04-18 ISSUED 04-30-18 DAVIS B EWS DESIGN GROVP 150 STATE STREET EAST OLDSMAR, FWRIDA 34677 813. 925 .1300 TEL.. 813.925.1800 FAX W W W.AAVISBEWS.COM TAMPA • DEl% ffi EST.1994 w Y O O �z O° O car) p=mq O H O 000 N J >7 0 2582 , • TITLE UPPER FLOOR ELEC. PLAN v1 MI�I�1111 SHEET • I i l i I ill it III � it S1-�II 141-411 FLOOR TRUSSES 301-011 ROOF TRUSSES_ ,;rem 1 � \ ••. a 0 0 i FRAMING FA ENER CAPACITY LEGEND + ti•0��5����� O FRAME TKO MA510NRY) (1) IOd w! (4) I/4 x 2 I/4 TITEN (TYP . I I EM ED AB NTO MASONRY ICO. BLOCK 12" (M N) 5E TBO 05 IN �II � • 11®w®�� �2 51MP50N METAI8-40 - (8) IOd x 1-1/2" (TYP. FRAME TO MASONRY) 51MP50N SET-XP EPDXY. (TYP S.Y.P. FRAME TO MASONRY) @ 51MP50N HIDA - (IS) IOd X 11/2" (TYP. 5YP FRAME) 3 T 51MP50N M5TAM24 - (9) IOd w/ (5)1/4" x 2 I/4" TITEN (TYP. FRAME TO MA5ONRY) 13 51MP60N MT512 - (14) IOd 11/211 ITYP, 5YP FRAME TO FRAME ® 51MP50N LTT205 - (10)-10d + 1/2" x 10" A.13(TYP. FRAME TO ALL-AROUND) MA5/FRM ALL-AROUND) 14 51MP50N L5TA18 - (14)10d (TYP. FRAME TO FRAME) 51MP50N HETA20 - (9)-10d x 11/2" (TYP. 5YP FRAME TO MA5ONRY ALL-AROUND) lg 51MP6ON HT520 - (24) IOd 11/2" or (20) had (TYP. 5YP FRAME TO 51MP50N HTT4 - (1) 5/8" dia. A.S. + 18.16d BOLT IN 51MP50N 5ET FRAME ALL-AROUND) EPDXY. EMBED A.B. 5" (MIN.) INTO CONCRETE (TYP. 5YP FRAME 16 51MP50N L5TA30 - (22)10d (TYP. FRAME TO FRAME ALL-AROUND) TO CONCRETE) 51MP50N HTT4 - (I) 5/8" DIA. AIR + (18)16D. EMBED A.B. INTO (2) 8IMP50N MT518 - (14)10d 11/2' AT EA. 5TRAP (TYP. 5YP FRAME TO MA50NRY K,O. BLOCK 6" (MIN) INTO MA50NRY K.O. BLOCK WITH FRAME) 51MP50N 5ET EPDXY. (TYP. 5YP FRAME TO MASONRY) 18 (2) 51MP50N HT620 - (24) IOd 11/2" AT EA, STRAP ITYP, 5YP FRAME TO FRAME) 51MP50N HTT4 - (I) 5/8" DIA. AIR + (18)16D. EMBED AB. INTO MA50NRY K.O. BLOCK 12" (MIN) INTO MASONRY K.O. BLOCK WITH 51MP50N 5ET-XP EPDXY, (TYP. 5YP FRAME TO MA50NRY) lg 5IMP50N 5T6224 - (28)16d (TYP. FRAME TO FRAME ALL-AROUND) 5IMP60N MGT - (1) 5/8 DIA. ATR. + 22-IOd. EMBED ATR 12" (MIN) INTO MA50NRY K.O. BLOCK WITH 51MP50N 5ET-XP EPDXY. (TYP 2� (3) 5IMP80N HT520 - (24)10d 11/2" AT EA. STRAP (TYP. S.Y.P. FRAME TO FRAME) 2-PLY TRU55 HEEL TO MA5ONRY) 21 (4) 51MP5ON HT520 - (24)10d 11/2" AT EA. STRAP (TYP. 5YP FRAME 51MP50N LGT3.5D5 2.5 (12)1/4" x 3" 5D8 AND (4) 3/8" x 5" TITEN HD INTO WALL WITH MGT A5 DESCRIBED IN CONNECTION 1(TYP. FOR 3-PLY TRU55 HEEL MASONRY) TO FRAME ALL-AROUND) 22 SEE GABLE END DETAIL ENGINEER DETAIL PAGES ® 51MP50N M5TAM 36 - (4)1/4" x 2 1/4" TITEN TO BLOCK AND 1-10d TO FRAME 23 5EE INTERIOR LOAD -BEARING PARTITION DETAIL ENGINEER PAGES a 51MP50N HTT5KT - (1) 5/8" DIA. A.B.+ 26-5D 10" x 2112" BOLT IN 5IMP50N 5ET EPDXY. EMBED A.B. 5" (MIN) INTO CONCRETE (TYP. 5YP 24 6IMP50N HT5MI6 - (8) ISd x 11/2" w/ (4)1/4" x 2 114" TITEN 2 (TYP. SYP FRAME TO MA50NRY ALL-AROUND) FRAME TO CONCRETE) 25 51MP50N M5TCM40 W/ (14)-16d 51NKER5 AND (10)1/4" x 2 114" TITEN 2 1� 6IMP50N HGT-2 (2 ply member)-(2) 3/4" DIA, A5, + 16-10d EMBED 5CREW5 A.B. INTO MA50NRY K.O. BLOCK 12" (MIN) 5ET BOLT5 IN 6IMR50N 5ET-XP EPDXY. (TYP 6Y.P. FRAME TO MA5ONRY) 51MP50N M6TGM60 W/ (20)-16d SINKERS AND (14)1/4" x 2 1/4" TITEN 2 SCREWS NOT 5: I. TRU55E5 ARE SHOWN A5 PROVIDED BY THE MFGR, CONTRACTOR SHALL REFER TO THE FINAL TRU55 ENGINEERING PACKAGE FOR CON5TRUCTION ALTERNATE STRAPPING: MAYBE USED IF 5TRAPPING 15 EQUAL TO OR GREATER THAN THE LOAD VALUE OF THE 5TRAPPING 1­15TED. 2. CAPACITIE5 ARE A5 PER 51MP50N 5TRONG-TIE CATALOG (C-C-2011), AND ARE PROVIDED FOR REFERENCE. 5EE MANUF. FOR OFFICIAL CAPACITIES AND INSTALLATION CRITERIA FRAMING PLAN 15 DIAGRAMMATIC IN NATURE AND 15 PROVIDED FOR ILLU5TRATION PURP05E5 ONLY. TRU55 MANUFACTURER TO PROVIDE 5EPARATE LAYOUT AND TRU55 COMPONENT DESIGN 516NED AND 5EALED BY A FLORIDA REGISTERED PROFE55IONAL ENGINEER. T U33 DE51 N NOTE. ADDITIONAL DELEGATED TRU55 MANUFACTURER'5 IN5TRUCTION5 MAY BE FOUND ON SHEET N-1 AND 5HALL BE COMPLIED WITH IN FULL, UNLEN NOTED OTHEROE: I: ALL ONE 5T0 Y MA50NRY TO TRU55 CONNECTIONS TO BE 51MP50N META20 (AT EACH TRU55) W1 (5) IOd x 1-1/2" (UND,) 2: ALL TWO STORY MA50NRY TO TRU55 CONNECTION5 TO BE 51MP50N HETA20 (32" O.C. MAX.) 10d x 1-1/2" (*,5EE STRUCTURAL 5HEET5 FOR ADDITIONAL 5TRAPPING REQUIRED,*) (UN.O.) 3. ALL FRAME TO TRU55 CONNECTION5 TO BE 51MP50N HIOA W! (IS)10d x 1.1/2" OR 51MP50N HT520 W/ (24) loci x 1.1/2" ITYP, FRAME TO FRAME ALL-AROUND (U.N.O.) 4. AT 5ECOND FLOOR FRAME TO FIRST FLOOR MA50NRY WALL CONNECTION5 A 51MPSON MSTCM60 MAY BE 5U55TITUTED FOR ANY HTT4 CALLOUT WHERE THE M$TCM60 CAN BE IN5TALLED PER MANUFACTURER'S 5PECIFICATION5 FOR FULL CAPACITY 5PECIFIC,4TION FOR LE©GER6 (THE FOLLOUJIN SHALL AF=F-LY U.N.O.) LEDGER A (LA) - 2x4 PT W/ 114" DIA. x 3" TAPCONS AT 12" O.C. SET AT SHEATHING LEVEL FOR DIAPHRAGM EDGE NAILING (TYP. UNO AT LOUDER ROOF TO UPPER WALL AT PARALLEL TRUSSES). NOTE: THIS IS A REQUIRED TERMINATION FOR THE SHEATHING DIAPHRAGM, AND PROVIDES LATERAL DIAPHRAGM SUPPORT TO THE MASONRY WALL. A TRUSS SISTERED TO THE WALL 15 NOT AN ACCEPTABLE SUBSTITUTE, UNLESS THAT TRUSS IS ATTACHED TO THE WALL IN LIKE MANNER TO THAT INDICATED FOR THE LEDGER (MIN.). LEDGER B (LB) - 2x4 W/ (3) 0.131" x 3-1/2" R.S. NAILS AT EA. STUD 116" O.G. MAX.) SET AT SHEATHING LEVEL FOR DIAPHRAGM EDGE NAILING (TYP. UNO). NOTE: THIS 15 A REQUIRED TERMINATION FOR THE SHEATHING DIAPHRAGM, AND PROVIDES LATERAL DIAPHRAGM SUPPORT TO THE FRAME WALL. A TRU55 515TERED TO THE WALL 15 NOT AN ACCEPTABLE 6U55TITUTE, UNLESS THAT TRU55 15 ATTACHED TO THE WALL IN LIKE MANNER TO THAT INDICATED FOR THE LEDGER (MIN.). LEDGER C (LC) - (2) 2x8 PT W/ 5/8" DIA. x 8" A.5. AT 12" O.C. STAGGERED W1 SIMPSON HU/HUC28 AT FACE ATTACHMENT OR HT516 AT TOP CHORD BEARING AT EA. TRUSS (TYP. UNO), ALTERNATE EQUAL OR BETTER CONNECTORS ARE ACCEPTABLE, LEDGER D (LD) - (2) 2x8 PT W1 (4) SIMPSON 5D525600 SCREWS AT EA. STUD (1(o" O.G. MAX.) W1 SIMPSON 1-4U/HUC28 AT FACE ATTACHMENT OR HT816 AT TOP CHORD BEARING AT EA. TRUSS (TYP. UNO). ALTERNATE EQUAL OR SETTER CONNECTORS ARE ACCEPTABLE. LEDGER E (LE) - (2) 2x12 PT W1 5/6" DIA. x 8" A.5. AT 12" O.G. STAGGERED W/ SIMPSON H4 MIN. OR EQUAL AT TOP CHORD BEARING OR SIMPSON 1-4U/HUC410 OR EQUAL AT FACE BEARING AT EA. TRUSS (TYP. UNO AT PERPENDICULAR FLOOR TRU55 5UPPORT ALONG MASONRY WALL). LEDGER F (LF) - 2x8 PT W1 5/6" DIA. x 8" A.B. AT 24" O.C. STAGGERED SET AT SHEATHING LEVEL FOR DIAPHRAGM EDGE NAILING (TYP. UNO AT FLOOR SHEATHING SUPPORT AT MASONRY AT PARALLEL FLOOR TRUSSES). NOTE: THIS IS A REQUIRED TERMINATION FOR THE FLOOR DIAPHRAGM, AND PROVIDES LATERAL DIAPHRAGM SUPPORT TO THE MASONRY WALL. A TRUSS 51STERED TO THE WALL 15 NOT AN ACCEPTABLE 5U55TITUTE, UNLESS THAT TRU55 15 ATTACHED TO THE WALL IN LIKE MANNER TO THAT INDICATED FOR THE LEDGER (MIN.). LEDGER G (LG) - (1) 2x8 W/ (4) SIMPSON 5D525600 SCREWS AT EA, STUD 06" O.C. MAX.) W/ SIMPSON HU/HUC28 AT FACE ATTACHMENT OR HTSI6 AT TOP CHORD BEARING AT EA. TRUSS (TYP. UNO). ALTERNATE EQUAL OR 5ETTER CONNECTORS ARE ACCEPTABLE. NOTE: AT LEDGERS C OR D,.HU/HUCZ4.�-2 OR HU/HUC28-3 MAY IBE USED FO 2 Y OR 3 Y HAN R TRUSS ATTACHMENT, RESPECTIVELY, U.N.O. 101916 TRADITIONAL ELEVATION "A" TRUSS STRAPPING PLANS GARAGE RIGHT K w C U �o o10 0 j co I o S) c~7 C •� .N N Cat) >>Ja t L. �• QQLLM• 0 0 � � ,j r, L. 0JCp roCD i Jc 4. 00 T Z N L 01 • JOB NUMBER B-1812154• CAD FILE NAME LOT 281 BASE 01- 04-18 ISSUED 04-30--18 DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDSMAR, FLORIDA 34677 813. 925.1300 TEL 813.925.1800 FAX W W W.DAVISBEWS.COM T,kNAPA • DEIVVER. EST. 1994 F---- re, i11 ii VORTEX ENGINEERING, LLC. 607 S. ALEXANDER ST., SUITE 103 PLANT CITY, FLORIDA 33563 813.704.4842 COA 28035 PAUL D. KIDWELL, P.E. #52683 ANDREW J. MEISHEID, P.E. #83217 1 HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED DESIGN, AND FIND IT TO BE IN COMPLIANCE WITH SECTION R301 OF THE FLORIDA BUILDING CODE, RESIDENTIAL STH EDITION (2017). THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUF. LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER. SEALED FOR STRUCTURE ONLY 2582 • • TITLE � • TRUSS STRAPPING PLAN • _T EET • TR GENERAL NOTES: CEILING COMPONENTS AT ENTRY8 LANAI: FRONT ENTRY AND LANAI CEILING5 TO BE 1/5" 5TUGGO OVER 1/16" 065 AND ATTACHED PER THE ROOF CRITERIA WITHIN THE "TYPICAL NAILING 5GHEDULE5 (FLOOR, ROOF, WALL)" A5 PER DETAIL 0/62. PRE-ENGINEERED WOOD PRODUCTS: • ALL PRE-ENGINEERED WOOD PRODUCTS SHALL BE VERIFIED BY TRU55 MANUFACTURER. TRU55 MANUFACTURER SHALL HAVE THE AUTHORITY TO MAKE 5U56TITUTION5 FOR PRODUCTS SPECIFIED ON THE PLANS DUE TO AVAILABILITY OR ECONOMIC5. CHANGES SPECIFIED BY THE TRUSS MANUFACTURER 5HALL CONTROL. CHANGE5 MADE AFTER TRU55 ENGINEERING HAS BEEN PROVIDED TO ENGINEER OF RECORD, MUST BE APPROVED BY THE ENGINEER OF RECORD. • ALL PRE-ENGINEERED WOOD PRODUCT5 ARE THE RESPONSIBILITY OF THE TRUSS MANUFACTURER. THE TRUSS ENGINEER 15 A DELEGATED ENGINEER FOR THIS PROJECT 4 A5 SUCH, 15 RE5PON515LE FOR THE VALIDITY OF THE COMPONENTS PROVIDED. FRAMING LAYOUTS SHOWN MAY BE CHANGED BY THE TRU55 MANUFACTURER. THE DELEGATED ENGINEER 15 RE5PON515LE FOR PROVIDING A FINAL SEALED SET OF ALL CALCULATIONS 4 LAYOUT5 FOR TH15 PROJECT TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO MANUFACTURE OF SAID COMPONENT5. ENGINEER OF RECORD HA5 NOT REVIEWED THE PRE-ENGINEERED TRUS5 MANUFACTURER'S COMPONENTS e TH15 TIME 8 RESERVE5 THE RIGHT TO MAKE ANY CHANGES AFTER SUCH INFORMATION HAS BEEN PROVIDED FOR REVIEW. CONTRACTOR, AS PROJECT COORDINATOR, SHALL BE RE5PON515LE FOR INSURING INFORMATION REQUESTED ABOVE HAS BEEN 5U5MITTED TO ENGINEER OF RECORD IN A TIMELY MANNER WHEN AVAILABLE. • ALL PRE-ENGINEERED TRU55E5 TO BE DESIGNED USING THE M05T RECENT TPI CRITERIA. TRU55E5 TO BE HANDLED $ INSTALLED USING MOST RECENT 5C51 RECOMMENDATIONS. TEMPORARY 8 PERMANENT BRACING SHALL BE PER MOST RECENT 5C51 RECOMMENDATIONS UNLE55 NOTED OTHERWISE, OR MORE STRINGENT CODE REQUIREMENTS APPLY. TRU55 ENGINEER 15 RESPONSIBLE FOR INDICATING ALL TRUSS TO TRU55 CONNECTORS. ALL COM='ONENT5 TO BE DE5IGNED FOR BOTH GRAVITY # UPLIFT LOAD CASES, INCLUDING BEAM COMPONENTS. • NOTE: UPON REVIEW, ENGINEER OF RECORD WILL PROVIDE A REVIEW LETTER INDICATING ANY CHANGE IN STRAPPING OR SUPPORT BASED ON THAT REVIEW. CONSTRUCTION COMMENCING PRIOR TO ENGINEER'S REVIEW 15 SUBJECT TO MODIFICATION BASED ON REVIEW LETTER. • TRU55 CONNECTIONS SPECIFIED BY THE TRUSS MANUFACTURER SHALL CONTROL. • THE ENGINEERING DETAILS SHOWN HEREIN 5HALL CONTROL IF THERE 15 A DIFFERENCE OF CONNECTOR 6PECIFICATION5 IN ANY OTHER PART OR PORTION OF THE PLAN SET. PRECAST CONCRETE COMPONENTS: • THE USE OF PRE -CAST 8 PRE-5TRE55ED CONCRETE COMPONENTS 15 ANTICIPATED IN THIS DESIGN, NAMELY LINTEL5 AND WIND RE515TANT SILLS 5HALL BE USED THROUGHOUT UNLESS SPECIFICALLY STATED OTHERWISE. ALL COMPONENT5 SHALL BE INSTALLED PER MANUFACTURER'5 5PECIFICATIONS, PRE -CAST LINTEL5 HAVE BEEN REVIEWED d PLACED BASED ON THE DE51GN ALLOWABLE LOAD INFORMATION PROVIDED BY CASTCRETE. USE OF CA5TCRETE LINTEL5 AND BILLS OR A STRUCTURAL EQUIVALENT BY ANOTHER MANUFACTURER 15 REQUIRED. MANUFACTURED PRODUCTS: • ALL MANUFACTURED PRODUCTS 5UCH 45: ROOFING, WINDOWS, DOORS, ETC. ARE SHOWN HEREIN FOR ILLU5TRATION PURP05E5 ONLY. • THE INFORMATION SHOWN 15 THE RE5PON515ILITY OF THE MANUFACTURER, THE MANUFACTURER 15 RESPONSIBLE FOR THE VALIDITY OF THE COMPONENTS PROVIDED, ATTACHMENT INFORMATION GIVEN BY THE MANUFACTURER 15 PROVIDED HEREIN. CONTRACTOR, AS PROJECT COORDINATOR, 5HALL BE RESPONSIBLE FOR INSURING THAT THE APPROPRIATE PRODUCT/COMPONENT 15 U5ED 4 THAT IT HAS BEEN INSTALLED PER MANUFACTURER'S 5PECIFICATION5 SUCH THAT IT WILL WITHSTAND THE COMPONENTS 4 CLADDING PRE55URE5 REQUIRED BY THE SEALED PLAN5. of NOTE: ENGINEER OF RECORD HAS NOT REVIEWED THIS INFORMATION FOR APPLICABILITY OR A5 A FORM OF PRODUCT APPROVAL OR ENDORSEMENT. FRAMING, DRYWALL 8 TRIM:_ • ALL WALLS 4 KNEE WALL5 SURROUNDING STAIRWELLS ARE TO BE FRAMED a 1(o" O.C. TO PROTECT FROM FALLING HAZARD. • ALL KNEE WALL5 WHICH ALSO ACT 45 GUARDRAIL5 SURROUNDING STAIR, BALCONY, OR VOLUME ,AREA5 5HALL BE ANCHORED 5UFFIGIENT TO RESIST THE LATERAL AND/OR VERTICAL LOADS REQUIRED BY CODE FOR FALL PROTECTION. THE FOLLOWING SUGGESTED ATTACHMENTS ARE INTENDED TO PROVIDE A 5,45E GUIDELINE IN THE ABSENCE OF ANY OTHER DIRECTIVE AND SHALL APPLY WHERE AN •• ALTEATLOCATIONS WHERE THE FLLOOR 5Y5TING EM BELOW THE GUARDRAIL 15 PERPENDICULAR, AT 4a" D.C. MAX. (1) 2X4 STUD WITHIN THE KNEE WALL 5HALL PENETRATE THE BOTTOM PLATE OF THE KNEE WALL AND FLOOR SHEATHING AND SHALL "515TER" ALONG5IDE THE FLOOR TRU55/JOIST/BEAM AND 5HALL NAIL TO THAT FLOOR TRU55 WITH (3) 0.131 X 3-1/2" NAIL5 AT BOTH THE TOP CHORD AND BOTTOM CHORD, OR IF THE TRU55 HAS A VERTICAL WEB COMPONENT AT THE "515TERED" LOCATION (6) 0,131 X 3-1/2" NAILS EQUALLY SPACED •• ATDLOCATISTAGGERED ERE TMAY BHE FLOOR SED SYSTEM BELNG THE OW THEGUARDRAILGTH OF 5 PARAL EL TOD'' STUD INTO �THE•: GUUARDRAIVERTICAL L BT E 50T OM PLATE OF THE GUARDRAIL KNEE WALL 5HALL BE ATTACHED TO THE PARALLEL FLOOR 5UPPORT BELOW WITH (2) ROWS OF 51MP80N 5D525600 5CREW5 AT a" O.C. ALONG THE LENGTH OF THE KNEE WALL. IN ADDITION, THE 61DE OF THE KNEEWALL ADJACENT TO THE OPENING 5HALL BE FULLY SHEATHED WITH 7/1ro" 055 OR EQUAL FROM THE TOP PLATE OF THE KNEEWALL TO THE BOTTOM OF THE FLOOR SUPPORT BELOW, NAILED PER THE "WALL" NAILING PATTERN (SHEATHING MAY BE VERTICALLY ORIENTED), BRIDGING THE HINGE POINT. ON THE NON -OPENING 51DE OF THE KNEEWALL, THE KNEE WALL 5TUD5 5HALL ATTACH TO THE BOTTOM PLATE WITH 51MP50N 5PI CONNECTORS AT EACH 5TUD. •• IF A GUARDRAIL/KNEE WALL TERMINATES AT A FULL HEIGHT WALL, A CRIPPLE STUD SHALL BE 515TERED TO THE FULL HEIGHT STUD AND SHALL BE NAILED WITH (6) Od 131 X 3-1/2" NAILS 5TAGGERED AND EQUALLY SPACED, AND THE DOUBLE TOP PLATE OF THE KNEE WALL SHALL BE NAILED TO THE FULL HEIGHT STUD WITH (4) 0.131 X 3-1/2'' TOE NAIL5. TH16 ATTACHMENT 5HALL ALSO APPLY AT ALL CHANGES OF DIRECTION AT THE KNEE WALL. •• ALL KNEEWALLS THAT AL50 FORM GUARDRAILS SHALL HAVE DOUBLE 2X TOP PLATES, 5TRUCTURALLY CONTINUOUS. •• EACH STUD WITHIN THE KNEEWALL 5HALL BE ATTACHED TO BOTH THE. TOP AND BOTTOM PLATES WITH (3) 0.131 X 3-1/2 TOE NAIL5 OR EQUAL. TNUMEROUS •• UNDERSTANDING THAT THESE ATTACHMENTS AND WALL CONVARY GREATLY- MAY VARGREATLY THAT HA E SYST M5 ARE AVAILABLE IN THE MARKETPLACE TO PROVIDE 5UFFIGIENT RESISTIVITY FOR THESE LOADS, IT 15 NOT THE INTENT OF TH16 PROVISION TO LIMIT THE USE OF ALTERNATE ATTACHMENTS. • 1 B 2 STORY HOMES W/O HABITABLE ROOM ABOVE GARAGE: ALL FRAME GARAGE WALLS 8 CEILINGS TO BE 1/2" DRYWALL. • 2 STORY HOMES W/ HABITABLE ROOM ABOVE GARAGE: ALL GARAGE CEILING TO BE 5/8" TYPE "X" DRYWALL ALL FRAME GARAGE WALL5 TO BE 1/2" DRYWALL. • ALL DOORS FROM GARAGE ADJACENT TO LIVING SPACE MUST BE EITHER A SOLID CORE DOOR OR HAVE A MIN. FIRE RATING OF 20 MINUTE5. • FRONT ENTRY 8 LANAI CEILINGS TO BE 1/5" 5TUCCO OVER 15/32'' 065. ROOFING 4 FLASHING (NOTE SEE ELEVATION PAGE FQR ROOFING TYPE): • R904.5.1 NAILS: •. NAIL5 5HALL BECORR0510N-RE515TANT NAL15 CONFORMING TO A5TM F1(o67 OR AN EQUAL CORROSION RE515TANCE BY COATING, ELECTRO GALVANIZATION, MECHANOCAL GALVANIZATION, 8TAINLE55 STEEL, NONFERROUS METAL AND ALLOYS OR OTHER SUITABLE CORRO51ON RE516TANT MATERIAL, OR CORROSION RE515TANCE 5HALL BE DEMON5TRATED IN ACCORDANCE WITH TAS114, APPENDIX E. • 5HINGLE UNDERLAYMENT: MIN. 30* FELT (OR PEAL 4 STICK) INSTALLED PER MANUFACTURE 5PEC6 * FBCR 905.1.1 • TILE UNQERLAYMENT: PEAL 8 STICK ROOF MEMBRANE INSTALL PER MANUFACTURE 5PEC5 • ALL ROOF/WALL FLASHING TO BE MIN, 2(o GAUGE GALVANIZED STEEL FLASHING. FLASHING TO BE DONE AL ALL ROOF TO WALL CONNECTIONS. BRICK 6 STONE: • BRICK/STONE SHALL BE SELF SUPPORTING. MA60N SHALL PROVIDE ANGLE SUPPORT AT OPENINGS SUCH THAT IT SPANS THE OPENING 4 DOES NOT ADD WEIGHT TO HEADERS. HEADERS PROVIDE LATERAL 5UPPORT ONLY. • AT MASONRY, USE (o"X(o"X3/8" 5TEEL ANGLE W/ 1/2" DIA. X 5" SIMP50N TITEN HD ANCHORS e 24 O.C. W/ 4" LAP ONTO BRICK 5UPPORT ON EITHER 51DE MINIMUM. ANGLE 51ZE PER B.I.A. 8 F.B.G. CRITERIA, OR BY OTHERS. • AT FRAME, U5E 5"X5"X3/8" 5TEEL ANGLE W/ 3/5" DIA. X 4" LAG 5CREW5 6 12" O.C. W/ 4" LAI ONTO BRICK SUPPORT ON EITHER 51DE MINIMUM. ANGLE 51ZE PER B.I.A. 4 F.B.G. CRITERIA, OR BY OTHER5. • BRICK/STONE T1E5, ANGLES SUPPORTS, AESTHETIC FIN15HE5 5HALL BE INSTALLED IN ACCORDANCE WITH THE TM5 402/ACI 530/45CE 5 A5 APPLICABLE. • VORTEX ENGINEERING, L.L.C. 16 NOT RE5PON51BLE FOR BRICK/STONE INSTALLATION INFORMATION, A5 5RICK/5TONE DE51GN 15 BY OTHERS. • SECOND FLOOR AREAS NOT IN ALIGNMENT WITH FIRST FLOOR AREAS HAVE BEEN ASSUMED TO REQUIRE BRICK/STONE BEARING ON TRU55 SYSTEM BELOW. TRUS5 MANUFACTURER TO INCLUDE ADDITIONAL DEAD LOAD FOR SUCH AREA5, & LIMIT DEFLECTION TO 1_/600 IN THESE AREA5 FOR PURP05E5 OF BRICK 5UPPORT. • FOUNDATIONS HAVE BEEN 61ZED FOR THE ADDITIONAL DEAD LOAD DUE TO BRICK/STONE. • BRICK/STONE & ITS SUPPORT EXCEPT 45 NOTED 15 BY OTHERS. NOTED CRITERIA 15 A MINIMUM STANDARD. TIES, FLA5HING5, WEEPS, CONTROL JOINTS, 4 ALL OTHER BRICK/STONE CRITERIA 15 BY OTHERS. • THE NOTES ABOVE PERTAIN TO CLAY BRICK MASONRY 8 NATURAL STONE. SIMULATED PRODUCTS 8 VENEER5 SHALL BE INSTALLED PER MANUFACTURER'5 5PECIFICATION6 4 THEIR FLORIDA PRODUCT APPROVAL OR MIAMI/DADE NOA. GENERAL STRUCTURAL NOTES: I. CODES 8 REFERENCE5: U. FLORIDA BUILDING; CODE, RESIDENTIAL loth EDITION. 1.2. AMERICAN CONCRETE INSTITUTE OF STRUCTURAL CONCRETE (ACI 318). 1.3. AMERICAN CONCRETE INSTITUTE OF MA50NRY 5TRUCTURE5 (TM5 402/ACI 530/145CE 5). 1.3.1 THE MA5ONRY 50CIETY DIRECT DE51GN HANDBOOK FOR MASONRY 5TRUCTURE5 (TM5 403). 1,4, AMERICAN SOCIETY OF CIVIL ENGINEER5 MINIMUM DE51GN LOAD5 FOR 5UILDING5 B OTHER STRUCTURES (A5CE-7). 1.5. 5PECIFICATION FOR THE DESIGN, FABRICATION & ERECTION OF 5TRUCTURAL STEEL FOR 5UILDING5 LATEST EDITION. 1.6. DE51GN 5PECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRU56ES BY THE TRU55 PLATE INSTITUTE (TPI) LATEST EDITION. 1.7, NATIONAL DE51GN 5PECIFIC4TION FOR WOOD CONSTRUCTION (ND5) LATEST EDITION. 1.8, AMERICAN PLYWOOD ASSOCIATION DESIGN CONSTRUCTION GUIDE. (APA) LATEST EDITION. 2, DE51GN CRITERIA: 2.1. ROOF LOADING: LIVE 20 PSF DEAD 7 PSF FOR 5HINGLE OR METAL 20 IPSF FOR TILE 2:2, FLOOR LOADING: LIVE 40 P5F DEAD 15 P5F MIN. (5EE NOTE 2.4) 2.3. RESIDENTIAL BA CONY LOADING; LIVE 40 PSF DEAD 15 PSF 2.4. FINISH MATERIAL DEAD LOAD NOTE5: 2.4.1. FIN15H FLOORING MATERIAL5 NOT EXCEEDING 5 PSF HAVE BEEN ANTICIPATED IN THE NUMBERS ABOVE. IT 15 THE CONTRACTOR'S RE5PON515ILITY TO DIRECT THE TRU55 MANUFACTURER TO INCREASE THE TCDL OF THE FLOOR T U5S 5 WHERE ANTICI ATED FIN15H MATERIAL WEIGHTS WILL BE HIGHER. 2.4.2. IT 15 THE CONTRACTOR'5 RESPONSIBILITY TO INFORM THE TRU55 MANUFACTURER AND ENGINEER IF ANTICIPATED FIN16H MATERIALS OR FIXTURE5 WILL EXCEED THE STANDARD INDUSTRY LOADS. GENERALLY STANDARD FLOORING IS AS PER 2.4J, STANDARD CEILING FINISH 15 5/8" OR LE66 GYPSUM MATERIAL. NON-STANDARD LOAD5 WOULD INCLUDE PLASTER OR TILE CEILINGS, LARGE CHANDELIER OR FAUX BEAM POINT LOADS, STONE SOAKER TUBS, MUD SET TILE FLOORING, STONE FLOORING, ETC, 2.5. WIND LOADING SEE TABLE FOR CRITERIA. 3. SOIL: 3.1. MINIMUM ALLOWABLE SOIL PRESSURE 15 45SUMED TO BE 2,000 PSF AS PER TABLE R401.4.1. 3.2. THE FOUNDATION SYSTEM FOR THE ATTACHED PROJECT IS DESIGNED FOR A MINIMUM ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF. 3.3. IT 15 THE CONTRACTOR'S RESPONSIBILITY TO VERIFY 501L CAPACITY 4 COMPACTION. 4. CONCRETE: 4.1. OPERATION INSTALLATION 8 PROCEDURE TO COMPLY WITH ACI STANDARDS. 4.2, CONCRETE 4 MINIMUM GOMPRE551VE STRENGTH OF 2500 psi a 2,5 DAYS (U.N.OJ. 4.3. REINFORCEMENT REBARS ASTM A& 15 GRADE 60 (U.N.O.). 4.4. WELD WIRE FABRIC (WWF ASTM 41(55) or FIBER ME5N PER 45TM C111(o TYPE III 4.13. USE 0,1% BY VOLUME MINIMUM (1.5 L55 / CU YD). 4.5. LAP SPLICES 8 NOOKS SEE TABLE. 5. MASONRY: 5J, MA50NRY CONSTRUCTION 8 MATERIAL5 SHALL CONFORM TO ALL REQUIREMENTS OF, "SPECIFICATION FOR MASONRY 5TRUCTURE5 (ACI 530RASCE (o/TM5 002)," PUBLISHED BY THE MASONRY SOCIETY, BOULDER, COLORADO: THE AMERICAN CONCRETE INSTITUTE, FARMINGTON HILLS, MICHIGAN: 8 THE AMERICAN SOCIETY OF CIVIL ENGINEERS, RESTON, VIRGINIA: EXCEPT AS MODIFIED BY THE REQUIREMENTS OF TIHESE CONTRACT DOCUMENTS. 5.2. GENERAL SPECIFICATION FOR MASONRY 5TRUCTURE5: 5.2.1, TE5TING OF FIELD MATERIALS FOR QUALITY CONTROL 15 NOT REQUIRED BY ENGINEER FOR THIS PROJECT. 5.2.2. COMPRE551VE STRENGTH REQUIREMENT 15 f'm=1500 PSI. 5.2.3, DETERMINATION OF COMPRESSIVE STRENGTH 15 THE ALLOWABLE 5TRE55 METHOD. 5.2.4. UNIT 5TRENGTH METHOD 15 NOT APPLICABLE. 5.2.5. QUALITY A55URANCE 15 NOT APPLICABLE. 5.2,ro, GROUT SHALL COMPLY WITH ASTM C476. GROUT 5HALL BE 3000 PSI U.N.O. 4 HAVE A SLUMP RANGE OF S"411 . 5.3. PRODUCTS: 5.3.1. MORTAR MATERIAL5 SHALL BE TYPE M OR 5 GRAY MORTAR. 5.3.2. MASONRY UNIT MATERIALS 5HALL BE ISOO PSI MIN. CONCRETE MASONRY UNIT. 5.3.3. REINFORCEMENT, PRE -STRESSED TENDONS, 4 METAL ACCE55ORIE5 SHALL BE (oO K51 REBAR (MIN.). 5.3.4, WELDED WIRE FABRIC TO BE INSTALLED A5 SPECIFIED ON PLAN SET. 5.3.5. 6TAINLE55 STEEL 15 NOT APPLICABLE. 5.3.0, COATING FOR CORROSION PROTECTION 15 NOT APPLICABLE. 5.3.7. CORROSION PROTECTION FOR TENDONS IS NOT APPLICABLE. 5.3.8. PRE-5TRE55ING ANCHORAGE, COUPLERS, 4 END BLOCKS ARE NOT APPLICABLE. 5.3.13. JOINT FILLER5 ARE NOT APPLICABLE. 5.3.10. LINTELS TO BE BY CAST-CRETE UNLE55 NOTED OTHERWISE. 5.4, EXECUTION: 5.4.1. PIPES 4 CONDUIT5 ARE NOT APPLICABLE. 5.4.2. ACCE55ORIE5 ARE NOT APPLICABLE. 5.4.3, MASONRY EXPAN510N AND CONTROL JOINT5 A5 INDICATED IN THE PLAN 5ET ARE RECOMMENDATIONS ONLY, UNLE55 CLEARLY DELINEATED AS "REQ'D." 5.4.4. WHEN USED, MASONRY CONTROL JOINTS SHOULD BE INSTALLED IN THE LOCATIONS SHOWN ON THE FLOOR PLAN AT A MINIMUM, BUT SHOULD FOLLOW THE PROVISIONS OF TM5 402/ACI 530/A5CE 5. MASONRY CONTROL JOINTS MAY BE INSTALLED IN ACCORDANCE WITH E/51 HOWEVER ALTERNATIVE ACCEPTAB LE CONTROL JOINT TYPES INCLUDE 'STANDARD VERTICAL - UNKE T ED CONTROL JOINT (3/8")' AND 'MICHIGAN CONTROL JOINT'. (o. WOOD FRAMING: 6.1. DIMENSIONED LUMBER SHALL BE DRE55ED 546, 4 SHALL BEAR THE GRADE 5TAMP OF THE MANUFACTURER'S A55OCIATION. 6.2. ALL LUMBER 5HALL BE SOUND, 5E,45ONED, 4 FREE FROM WARP. (0.3. FRAMING WALLS 4 COLUMNS (0 3J, MINIMUM OF 3 PLY 2x STUD 5.Y.P. COLUMNS TO BE INSTALLED a BEAM OR GIRDER TRU55 BEARING LOCATION5. UNLE55 NOTED OTHERWISE. &.3.2. ALL TRU55 BRACING; LUMBER SHALL BE S.Y.P. #2 OR BETTER. (0.3.3. INTERIOR LOAD BEARING WALL 5TUD5 TO BE SPACED '@ l(o" O.C. 8 SHALL BE S,Y.P. OR BETTER, U.N.O. 6.3.4. TYPICAL AT ALL LOAD BEARING 5.Y.P. COMPONENTS, 02 GRADE SHALL BE U5ED FOR 2x4, FOR 2X DEPTHS GREATER THAN 2x4, 1*2 GRADE OR BETTER MAY BE USED. ALL 4x MATERIAL MAY BE *12 GRADE U.N.O. �0.3.5. INTERIOR NON -LOAD BEARING WALL5 5HALL BE UTILITY GRADE OR BETTER, AND MAY BE SPF. (o.3.(o. INSTALL BLOCKING IN ALL WALL 5TUD5 OVER a'-O 0 MID -HEIGHT, 8 SHEATHING JOINT. BRACE GABLE END WALL5 a 4'-0 O.C. MIN. (0 3.7. ALL LOAD BEARING WALLS 5HALL HAVE S.Y.P. DOUBLE TOP AND SINGLE BOTTOM PLATES 4 5HALL BE FASTENED PER DETAILS HEREIN. INTERIOR BEARING; COLUMN5/5TUD PACK5 NEED NOT PENETRATE TOP AND BOTTOM PLATES AS LONG AS TOP PLATE 15 OF A LUMBER GRADE EQUAL TO OR BETTER THAN THE BOTTOM CHORD OF THE TRUSS/J015T ABOVE. (o.4. ALL LUMBER IN CONTACT WITH MA5ONR`r' OR CONCRETE SHALL BE PRE55URE TREATED OR NATURAL DURABLE WOOD. (o.5. PRESSURE TREATED LUMBER 5HALL BE IMPREGNATED WITH A CCA 5ALT TREATMENT IN ACCORDANCE WITH F.S. 11-W-571 4 BARE THE AMERICAN WOOD PRE5ERVE5 INSTITUTE EQUALITY MARK LP-2. (o.(o. ALL SHEATHING TO BE SPAN RATED FOR APPROPRIATE APPLICATION. ALL ROOF SHEATHING TO IN5TALLED WITH PLY CLIPS (MAXIMUM 24'' O.C.). (SEE PLAN5 FOR 5HEATHING THICKNE55.) FOR ALL SHEATHING ATTACHMENT, SEE TYPICAL NAILING SCHEDULE. INSTALL ALL 5HEATHING WITH EDGE GAP5 AS REQUIRED BY THE APA. (0,(0.1. ROOF SHEATHING SHINGLE OR METAL, 7/1(o" MIN. THICK APA RATED SHEATHING 5U1=PORTED OVER 24'' MAX. SPAN, AT TILE USE MIN. 15/32" THICK APA RATED SHEATHING 5UPPORTED OVER 24" MAX. 5PAN. CONTRACTOR 5HALL ADJUST MIN. SHEATHING CRITERIA, IF NECE65ARY, TO ACCOMODATE THE TILE MANUFACTURER'S WARRANTY REQUIREMENTS. THE M05T 5TRINGENT 5HALL CONTROL. 6.6.2. WALL. 7/1(o" MIN. THICK SUPPORTED OVER 24'' MAX. 5PAN. (O.&.3. FLOOR: CARPET, VINYL, WOOD, ETC., 3/4'' MIN. TONGUE 4 GROOVE 5UPPORTED OVER 24" MAX. SPAN CERAMIC TILE, MARBLE, ETC., SEE MANUFACTURER5 RECOMMENDATIONS AND/OR WARRANTY REQUIREMENTS.. GENERAL STRUCTURAL NOTES (CONT.): 6.7 ALL NAILING; 4 BOLTING SHALL COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION REQUIREMENTS. ALL NAILS EXPOSED TO THE EXTERIOR SHALL BE GALVANIZED. 6.0 ALL CONNECTION HARDWARE SHALL BE GALVANIZED / SUPPLIED BY 51MPSON STRONG; TIE CO., USP, OR EQUIVALENT. ALL NAIL HOLES SHALL BE FILLED OR AS PRESCRIBED BY THE MANUFACTURER. (o.9 BRACING;: TEMiPORARY BRACING OF THE ROOF SYSTEM SHALL BE IN5TALLED PER 5CS1 RECOMMENDATIONS 4 SHALL BE UTILIZED AS THE PERMANENT BRACING; FOR THE ROOF SYSTEM (U.N.O.). &.10 ALL WOOD FRAMING 5HALL BE IN COMPLIANCE WITH THE LATEST ND5 EDITION FOR WOOD CONSTRUCTION. (o.11 INTERIOR SHEAR WALL 5HALL BE CONSTRUCTED BY ATTACHING 7/1(o" APA RATED SHEATHING TO ONE SIDE WITH NAILING PATTERN PER '0'/52, ATTACH TO SLAB WITH 1/2" DIA x 10'' AB 24'' O.C. OR O WOOD FLOOR SYSTEM WITH (2) 51MP50N 5D525600 e 24" O.C. MAX. TO FLOOR TRU55E5 OR BLOCKING A5 APPLICAELE. AT TOP PLATE ABOVE ATTACH WITH 5IMP50N HT51(o OR TO BLOCKING ABOVE e 24'' O.C. A5 PER DETAIL 'F'/52. �LOGKINC� pE�INED (THE FOLLOWING SHALL PPLY U.N.O.) THROUGHOUT TH15 PLAN THE TERM BLOCKING 15 USED A5 A GENERIC TERM. THIS NOTE SEEKS TO CLARIFY PROPER BLOCKING TECHNIQUE:' • BLOCKING SHALL BE 2X4 #2 5YP, U.N.O. • BLOCKING SHALL BE ATTACHED WITH (3) 0.131X5-1/2" TOENAILS INTO THE STUDS AT EITHER END, U.N.O. • BLOCKING IN A WALL CAVITY 15 O BE INSTALLED IN THE SAME ORIENTATION AS THE BOTTOM PLATE (HORIZONTAL AND FLATWI5E), AND SHALL EXTEND TO FILL THE CAVITY FORMED BY THE STUDS. U.N.O. • BLOCKING WITHIN A FLOOR TRUSS WEB SPACE 15 TO BE ORIENTED THE SAME AS THE END VERTICAL OF THE TRU55 (ON END), AND 5HALL EXTEND FROM TOP TO BOTTOM CHORD, OR 1F INTERRUPTED BY DIAGONAL WEB COMPONENTS, IT SHALL EXTEND FROM THE TOP CHORD, TO THE WEB MEMBER, AND A SECOND PIECE SHALL BE INSTALLED FROM THE WEB MEMBER TO BOTTOM CHORD, ALIGNED VERTICALLY, U.N.O. • BLOCKING WITHIN A ROOF TRU55 WEB SPACE SHALL BE ORIENTED PERPENDICULAR TO THE BOTTOM CHORD, AND FLATWI5E WITHIN THE PLANE OF THE TRU55 WEB, ON END. BLOCKING WITHIN THE TRU55 SHALL EXTEND FROM BOTTOM CHORD TO TOP CHORD, OR IF INTERRUPTED BY DIAGONAL WEB COMPONENTS, IT SHALL EXTEND FROM THE TOP CHORD, TO WEB MEMBER, AND A SECOND PIECE 5HALL BE INSTALLED FROM THE WEB MEMBER TO BOTTOM CHORD, ALIGNED VERTICALLY, AS NECESSARY TO FACILITATE THE ITEM FOR WHICH BLOCKING 15 NEEDED, U.N.O. • BLOCKING USED TO FILL VOID SPACE (I.E. THE VOID SPACE BETWEEN THE BOTTOM PLATE OF AN UPPER WALL TO THE MASONRY OR FRAME WALL BELOW WITHIN THE AREA TAKEN UP BY TRU55 WORK.) FOR TRANSFERRING UPPER POINT LOADS (I.E. - STUD PACKS) TO LOWER COMPONENTS SHALL BE INSTALLED IN THE SAME ORIENTATION, OF THE SAME WOOD TYPE AND GRADE, AND OF THE SAME NUMBER OF PLIES, A5 THE STUD PACK ABOVE. • BLOCKING INSTALLED BETWEEN ADJACENT TRUSSES SHALL BE PERPENDICULAR TO THE TRUSS CHORD BEING BLOCKED, AND SHALL BE ORIENTED ON EDGE. EXCEPTION:. AT HIP AND VALLEY LOCATIONS BLOCKING WHICH SUPPORTS THE 5HEATHIN6 JOINTS MUST FOLLOW THE HIP OR VALLEY AND SHALL THEREFORE NOT BE PERPENDICULAR TO THE TRU55 CHORD BEING BLOCKED. U.N.O. • IN GENERAL BLOCKING INSTALLED AS PER THE CRITERIA ABOVE 15 INTENDED FOR 5TRAPPIN6, BRACING, AND SUPPORT, U.N.O. FICATION FOR 5UGK ATTACHMENT SPECIFICATION FORANCHOR BOLT5 (THE FOLLOWING SHALL APPLY UND.) O p Y O ATTACH WINDOW THROUGH BUCK TO ALL 1/2" DIA A.B. INTO THE TOP OF A MA50NRY KO BLOCK COURSE NRY/WOOD FRAMING. IF 2x - ATTACH TO 2x F SHALL HAVE A MINIMUM EMBEDMENT OF • ALL 1/2" DIA. OR 5/8" DIA. A.B. INTO THE SIDE OF FILLED MA50NRY ATTACH TO MASONRY w/ 1/4" x 3" MA50NRY5HALL HAVE A MINIMUM EMBEDMENT OFORS 12" O.C. w/ MAX. 6" FROM ENp OF BUCK. ALL 2x WINDOW BUCK ATTACHMENT.) ALL 1/2" DIA. A.B. INTO THE TOP OF A GROUTED MASONRY 5TEMWALL SHALL HAVE A MINIMUM EMBEDMENT OF • ALL 1/2" DIA. A.B. INTO THE TOP OF CONCRETE THICKENED 5LA55 SHALL LIMITATIONS (THE FOLLOWING PPLY U.N.O.) HAVE A MINIMUM EMBEDMENT OF 7" • ANY DIFFERING NOTATIONS FOR EMBEDMENT MADE ON THE PLAN SET EX ENGINEERING, LLC. HA5 CHECKED THE 5HALLCONTROL. HED DESIGN FOR ITS STRUCTURAL LIANCE WITH SECTION R301 OF THE FLORIDA • THESE NOTES ARE SPECIFICALLY FORANCHOR BOLTS WITH A 90 ING CODE, RESIDENTIAL 6TH ED., AND 15 NOT FDo DEGREE HOOK, THEY DO NOT APPLY TO ANY OTHER ANCHORAGE ONSIBLE FOR THE DE51GN'SARCHITECTURAL DEVICE. SPECIFICATIONS FOR THOSE DEVICES MUST ACCOMPANY THE R DRAFTING CRITERIA RE. - DIMENSIONS, NOTATION TO USE SAME.ETIC5, CONTINUITY OF LAYOUTS, ETC.) ANYNTINUITY IN DESIGN IS THE RESPONSIBILITYE DESIGNER. SPEGIFICATION FOR LANDINGS 4 STAIR CONSTRICTION r CA (THE FOLLOWING 5HALL APPLY U.N.O.) ;� J•"•"• 0 ALL 5TRINGER5 TO BE I� • ALL 5TRINGER5 TO ATTACH ACH ATLANDINGS 4 UPPER FLOOR LEVELS WITH SIMP5ON L5C HANGER. • STRINGERS RUNNING PARALLEL TO 6 SUPPORTED BY A WALL SHALL BE ATTACHED: •• 6 MA5ONRY/CONC. WITH a" DIA X 3" TAPCON5 AT 8" O.C. STAGGERED ALONG THE LENGTH OF THE STRINGER (USE PT AT MA5./CONC.). •• a WOOD WITH (4) 0.131 X 321" NAILS AT EA. STUD MIN. (16" O.C. MAX) •• IF 5TRINGER5 ARE 5UPPORTED IN THIS WAY, L5U HANGERS ARE NOT REQUIRED AT THE ENDS • ALL STRINGERS SPRINGING FROM A FLAT SURFACE SHALL TERMINATE AT A 2X4 FOOT (TO BE PT AT CONC.). ATTACH FOOT TO FLOOR: •• CONC. W/ 4" DIA. X 3" TAPCON5 Q 12" O.C. •• WOOD. ATTACH W/ 0.131 X 321" NAILS AT 8" O.G. TO TRU55/J015T/ OR BLOCKING BELOW. of ATTACH STRINGER TO FOOT WITH (2) 0.131X32'" TOENAILS EA. • LANDINGS SHALL BE BUILT AS FOLLOWS: •• JOISTS TO BE 2X8 02 5YP, MIN. 6 16" O.C. of IF LADING INCLUDES STRINGER SUPPORT IN A BEAM CONFIGURATION, BEAM SHALL BE (2) 2X12 12 5YP WITH 2-2X4 5UPPORT 5TUD5 AT EACH END. of IF LANDING 15 5UPPORTED BY A KNEEWALL, PROVIDE A 2X8 END J015T WITH (3) 0.131X3z" R.5. END NAILS AT EACH LANDING JOIST, 8 (2) 0,131 X 3�" TOE NAILS FROM EACH J015T TO KNEEWALL TOP PLATE. •• WITH: LEDGERS(4) ••• 0.13I NAIL5 AT EACH PASSING STUD AT WOOD ATTACHMENT 16" O.C. MAX. ••• " X 3" TAPCONS Q 8" O.C. STAGGERED Q M,45ONRY/CONCRETE ATTACHMENT. •• ATTACH JOISTS TO LEDGERS OR BEAMS WITH 51MP50N LU526 HANGERS OR EQUAL. • THE SPECIFICATION L15TED ABOVE OR MINIMUM SPECS. 5U55TITUTION5 OF EQUAL OR BETTER CAPACITY ARE ACCEPTABLE. • GUARDRAILS 8 HANDRAILS ARE BY OTHERS, INCLUDING; THEIR ATTACHMENTS. ALL RAIL SYSTEMS MUST MEET OR EXCEED THE REQUIREMENTS OF FBCR TABLE R301.5 6 SECTION R312. GONFLICTS (THE FOLLOWING SHALL APPLY U.N.O.) ULTIMATE WIND SPEED (Vult) 142 MPH • REGARDLE55 OF ANY NOTE TO THE CONTRARY IN NOMINAL WIND SPEED (Valt) 110 MPH THE PLAN SET, EXCEPT AS INDICATED BELOW, IN RISK CATEGORY II ANY LOCATION WHERE THE PLAN SPECIFICATIONS WIND EXPOSURE C SEEM TO CONFLICT WITH THEMSELVES, THE CODE, INT, PRESSURE COEFF. +/- 0.18 ENCLOSED OR THE MANUFACTURER'S SPECIFICATIONS, THE M05T STRINGENT CRITERIA SHALL APPLY. MAX. MEAN ROOF HEIGHT 27.5' MAX. • WHERE A SEALED DIRECTIVE FROM THE ENGINEER OF RECORD 15 PROVIDED RELATING TO A COMPONENTS AND CLADDING (ULTIMATE) CONFLICTED ITEM, THAT DIRECTIVE SHALL CONTROL. ROOF © 10 SQFT + 28.6 /- 1.17.1 PSF DISCLAIMER @ 20 SQFT + 26.5/-109.1 PSF (THE FOLLOWING SHALL APPLY U.N.O.) © 50 SQFT + 22.3 /- 99.4 PSF CONTRACTOR 15 TO VERIFY ,ALL DIMEN51ON5 IN THE Q 100 SQFT + 20.2 /- 91.8 PSF FIELD ,AND REPORT ,ANY D15CREPANCIE5 TO THE ENGINEER PRIOR TO STARTING ANY WORK. WALL © 10 SQFT + 49.7 - 66.7 PSF ,ANY GHANGE5 TO THESE PLANS, RE5ARDL.E55 OF © 20 SQFT + 46.3/- 62.3 PSF HOW MINOR, WITHOUT WRITTEN, SEALED APPROVAL © 50 SQFT + 44.6 /- 56.9 PSF OF VORTEX ENGINEERING, LLC, OR ANY Cal 100 SQFT + 42.1 /- 55.2 PSF GON5TRUCTION EXECUTED FROM THESE PLAINS Q 500 SQFT + 37.1 /- 41.3 PSF WITHOUT THE EXPRESS APPROVAL OF VORTEX ENGINEERING, LLC SHALL AUTOMATICALLY RENDER VORTEX ENGINEERING, L.L.C. HARMLF-55 TO ,ANY GARAGE DOOR 8' WIDTH + 44.3/- 49.4 PSF LIABILITY, CLAIMS, SUITS, OR LITIGATION BY ,ANY 10' WIDTH + 43.6 /- 48.9 PSF INTERESTED PARTIES IN THE PROJECT. IF BOUND SPEGIFIC,ATION5 ACCOMPANY THESE PLANS, THEY 12' WIDTH + 42.9/- 48.3 PSF SHOULD BE READ CAREFULLY FOR ADDITIONAL 16'+ WIDTH + 42.0/- 47.5 PSF CONDITIONS. CHART IS IN "ULTIMATE" PRESSURES. ALLOWABLE = 0.6 X ULTIMATE FOR COMPARISON CHART MAY BE INTERPOLATED FOR INTERMEDIATE PRESSURES GARAGE DOOR PRESSURES ASSUME 2' MAX IN END ZONE NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND REPORT ANY DISCREPANCIES TO ENGINEER PRIOR TO 5TARTING ANY WORK. THESE PLANS ARE THE PROPERTY OF VORTEX ENGINEERING, LLC., AND SHALL BE RETURNED UPON COMPLETION OF THE PROJECT. USE OR COPY 15 PERMITTED BY CONTRACT ONLY. ANY CHANGE5 TO THESE PLANS, REGARDLESS OF HOA MINOR, WITHOUT ARITTEN APPROVAL OF VORTEX ENGINEERING, LLC, OR ANY CONSTRUCTION EXECUTED FROM THESE PLANS AITHOUT THE EXPRESS APPROVAL OF VORTEX ENGINEERING, LLC SHALL AUTOMATICALLY RENDER VORTEX ENGINEERING, LLC. HARMLESS TO ANY LIABILITY, CL.AIM5, SUITS, OR LITIGATION BY ANY INTERESTED PARTIES IN THE PROJECT. IF BOUND SPECIFICATIONS ACCOMPANY THESE PLANS, THEY SHOULD BE READ CAREFULLY FOR ADDITIONAL CONDITIONS. REVISIONS BY NEW CODE UPDATES DK/PK REVISIONS ADDED 142 MPH SHEETS DK/PK REVISIONS ADDED 160 MPH SHEETS DK/PK REVISIONS GEN NOTE REVISED DK/PK w A Z N p Oz wOv00w wWr •+` z z i a w -2 2. H H OQa � 3asW W f1 w0Eua �LL= 3gzzb o n rl _ OwO w f = V cA M > T5 X<2< �Zzz o2z2gz J w o0 FQOQ zn�omOk =�Q= W O yy0 � p �"�- ^y cc Ll. Q 0 W �� Q zw>w0 �7 J pC LL ww30 C9za�v-'i W >v�'U wUwwj -j Z mall wz LU C C W Q W Q K W W Gn � o a M au Ln W Z co m 00 ui W H d� O3., i11 Z W O d C4 0 C9 z U- o <C W Z M O 0 t-4 V J �j LL X Q H- a w Z N a IX CL 00 � �o 0� u_ O ° J LLj • s DATE (IJ3-l218-IB SCALE NO7ELO DRAWN MK/POK JOB - content: Structural Notes Sheet number: N1 142-21.5 1/2" DiA. x 8" TITEN HD 6 48" O,C, MAX (SEE FOUNDATION PLAN FOR LOCATION OR EXCEPTIO 5) PRE- ENGINEERED WOOD TRU55E5 e 24" O/C 12 UPLIFT CONNECTOR (SEE TRUS5 (TYP) SEE ELEV. SHEET FOR SCHEDULE) 51MP50N 6P2 6 EA,5TUD - 1116" APA RATED 5HEATHIN SEE SCHEDULE FOR DOUBLE 112X" FASTENING 5.P.F. TOP PLATE 2X4 PT 5TUD5 s 16" O,G, OR CRICKET AS (1)2X4 PT STUD 6 24" O.C. REQUIRED UNDER COMMON TRU55 W/(2) 2X4PT STUDS UNDER HIP CARRIER/GIRDER TRU65 - SIMP50N BPI e EA. STUD MAIN SPAN ROOF TRU55 2x4 PT. BTM. PLATE W/ 1/2'' DIA.x6" A.B. e 24" D.C. UPLIFT CONNECTOR (SEE SCHEDULE) 51MP50N META20 a EA.5TUD MOISTURE BARRIER 8"X0"X16" K.O. BLOCK W/I 05 CON . (1)#5 VERT, IN CONC.FILLED CELL 4 4 FILLED W/2500 P51 GROUT W/ STD. SO* HOOK IN K.O. BLOCK °\ d ° \ t It dQ ° a' LAP SPLICE EMBEDDED STD. 900 HOOK STD. 1800 HOOK REQUIRED LAP SPLICE, EMBEDMENT, 4 HOOKEID REINFORCING STEEL (INCHE5) GRADE 4sa GRADE 60 BAR 512E BEND DIAMETER LENGTH LAP SPLICE BEND DIAMETER LENGTH LAP SPLICE 11411 11511 �V`il �1 11011 11411 1150 �V`p PDO 03 11/8 41/2 15 2If//4" 41/2 911/4 16 04 21/2 6 91/2 20 3" 6 12 1/2 21 05 3 1/8 1.5 11 3/4 25 3 3/4" 1.5 15 1/2 26 "6 3 3/4 9 14 30 4 1/2" 9 18 1/2 35 4 3/8 10.5 16 1/2 35 5 1/4" 1P.5 21 3/4 53 "8 - 8" 12 24 3/4 14 9" 13.5 28 95 HATCHING LEGEND NOTE: "AT 2x6 WALLS USE 5PH6 CONNECTORS IN LIEU OF INTERIOR LOAD 5PH4 CONNECTORS SHOWN. F Kneewall Above MasonryWall Detail NOT FOR USE IN THE HVHZ (DARE, BROWARD) (4) 106 NAILS BEARING WALL (W/ CONNECTORS IN E 5PHO S 1 SCALE: NTS INTO DBL UPLIFT) TOP PLATE 5PH4 CONNECTORS SHOWN. TRU55 BRG. FOR WALLS LARGER THAN 1 Rebar Lap, Embedment & Hook Schedule SEE PLAN 2x8, USE 6IMP50N 5PI'5 ON NOTE: EACH SIDE OF STUD TO "J" BOLT W/ NUT 4 WASHER (REFER 70 S-1 SCALE: NTS BOTTOM PLATE 4 51MP50N DOOR MANUFACTURERS INSTALLATION REGARDLESS 5P2'S ON EACH 51DE OF IN5TRUCTION6 FOR SPACING 4 SIZE) STUD BEARING OF HATCHING FASTEN EA. STUD STUD TO TOP PLATES. "5 VERT. WALL NOTE: SHOWN ON REINF. GROUT "AT 2x6 WALLS USE 5PH6 CELL5 SOLID 2x6 P.T. JAMB WALL TO TOP PLATE w/ U.N.O." UPLIFT CONNECTOR CONNECTORS IN LIEU OF (SEE PLAN FOR PLANS, WALLS 51MP50N 5PH4 w/ a (SEE TRU55 SHEET - __ 5PH4 CONNECTORS SHOWN. THAT 5UPPORT SEE TRU55 SHEET FOR SIZE) 5YP 2x4 MIN. 12-10d NAILS 4 NOTE: FOR SCHEDULE) AT 2x8 WALLS USE SPHS STUDS a 16" O/C ROOF TRUSSES ADDITIONAL STRAPPING Q "NOTWITHSTANDING MANUFACTURER'S CONNECTORS IN LIEU OF EITHER COLUMNS SPECIFICATIONS, JAMB SHALL BE 2x6 6PH4 CONNECTORS SHOWN. DIRECTLY OR GARAGE TO STUD BEARING WALL (SEE MIN. 4 SHALL BE ATTACHED TO THE DBL. TOP PLATE (1) 51MP5ON 6PH4 W/02) 10d FOR WALLS LARGER THAN INDIRECTLY HOUSE WALLS; PLAN FOR SIZE) 5YP 2x4 MIN. MASONRY/CONCRETE w/ 1/2'' DIA. x 8" COMMON NAILS EA. STUD 2x8, USE SIMPSON 5P1'S ON GARAGE TO ARE TO BE 5TUD5 Q 16 O/C A.B, AT 24 O.C. STARTING 9 MAX, EACH SIDE OF STUD TO HOUSE WALLS, BUILT AS INSULATE PER TRACK/BRACKET FROM THE SLAB, USE 2" DIA. W,45HER5 1/2 GYP. BOARD 1/2" GYP. BOARD INSULATE PER BEARING WALL CALCB/SPECS O, DIA, x 8" TITEN UPLIFT 24" FASTEN PER MANUF. MIN. AT EACH BOLT LOCATION, TRACK 5BP2'S ON EACH SIDE OFON CALC5/8PEC5 O.G. FOR A MAX. UPLIFT OF # W/UPLIFT 1500 LBS. ON EACH TRUSS SPECS. ATTACHMENTS TO THE JAMB ARE BY 2X S.Y.P. I STUDS 6 16 O.G. STUD TO TOP PLATES. (1) SIMP50N 5PH4 (SEE FOUNDATION PLAN OR MANUFACTURER. THESE 5PECIFICATION5 SECURE PLATE W/ 10" 1/2" DIA U.N.O," w/ 12-106 NAILS EA. TRUSS PAGE FOR LOCATION ARE MIN. STANDARDS, MORE STRINGENT "J" 5OLT5 4 WASHERS v 2'-0" INSULATION OR PER ENERGY STUD (STRAP OR EXCEPTIONS) G Gara a Door Attachment Detail CRITERIA PROVIDED BY THE GARAGE O,C. (MAX.) CENTERED ON WALL. CALCS,/5PEC5, PT BOTTOM PLATE NEEDED ONLY DOOR MANUFACTURER SHALL (REFER TO FND 4 FLR PLN FOR W/ROOF UPLIFT) PT BOTTOM PLATE 3-� SCALE: NTS CONTROL. U.N.O." WALL THICKNESS) CONT. 2X PT SOLE PLATE ° m 4 OL -01-0" a A . m A 0'-0" pBL SYP TOP PLATE (1) SIMPSON BPH4 W/02) 106 ... 4"GONG, SLAB. SEE COMMON NAILS EA. STUD ...._-� FOR WOOD FRAME WALL TO FOUND. PLAN FOR I FOOTING SEE FOOTING SEE III- - FOUNDATION PLAN MASONRY ATTACHMENTS THAT MORE INFO. ,- - FOUNDATION PLAN FOR I =1 I I=I 11= EL V 0'-0" TOP OF SLAB III I 51ZE5 4 MORE INFO. FOR 51ZE5 4 MORE OCCUR e A LINTEL USE 1/2 x 6 _ INFO. THREADED ROD SET IN 5P4 TOP L Load Brn Interior Stud Part. Detail 51MPSON SET EPDXY. (� a s Load Brn Interior Stud Part. Detail Z $-1 SCALE: NTS SEE FOUND. PLAN Without Uplift SCALE: NTS With Uplift 2 X 5.Y.P. 5TUD5 16" O.G. - U,N,O. w FOOTING SEE p Uu FOUNDATION PLAN FOR LOAD BEARING OR N 5IZE5 4 MORE INFO. ";::fir• CLEAN 4 COMPACTED SOIL. SHINGLE / TILE ROOF - SEE ELEVATION PRE ENGINEERED WD EXTERIOR WALL 2 X STUD (95°r, MODIFIED PROCTOR PER A5TM D1551) PAGES FOR MORE INFO, FASTENING TO BE A5 12 PER MANUFACTURERS SPECIFICATIONS. SEE TRU55 24 O.G. CONTRACTOR TO PROVIDE MANUF, (TYP) ELEV. IO" x 1/2" DIA. "J" 8 C. M. U. j � Garage Wall Section Brn ScWall DOCUMENTATION TO INSPECTOR TIME OF R-38 INSULATION OR PER ENERGY CALC5. BOLT5 4 WASHERS 1 X P.T.STUD W/ Uplift f. IN5PECTION. IF SHINGLE IS USED, 2'-0" O.C. (MAX) N s VERT, IN FILLED UNDERLAYMENT TO COMPLY WITH FBCR META20 UNLESS NOTED OTHERWISE SEE CENTERED ON WALL CELL SO! J11 TRUSS SHEET FOR MORE INFO. FOR EXTERIOR 10 BRNG. OR GARAGE 1/2" DIA x 6" FLOOR BRNG WALL TITEN HD TRU55 (4) 106 NAILS INTO ELEVATION VARIES V DBL TOP PLATE BRG. :Of TOP OF MASONRY TITEN HD 48" O.G. IF 2 X P.T. PLATE SEE PLAN 5OFFIT/F,45CIA LESS THAN 5'-0" WALL 15 INTERIOR ry DBL. TOP PLATE FROM PROPERTY LINE TO BRNG WITHOUT 1/2" GYP. BD. CEILING COMPLY WITH FBCR 302.1. SEE UPLIFT. 24" O.C. IF EXTERIOR FIN15N I/2" GYP. BOARD TYP. SEE NOTE ON N-1 PAGE FOR GARAGE ELEVATION PAGES FOR 5OFFIT/FA5CIA DETAIL WITH UPLIFT. ° ' (SEE ELEVATIONS) SECURE PLATE W/ 10" 1/2 1/2" GYP. BOARD APPLICATION p ° °' _ - GRADE DIA, J BOLTS 4 VARIES SEE ROOF PLAN ; .. ° o ° '. WASHERS 6 4'-0" O.G. . p a (MAX.) CENTERED ON 2X S.Y.P. #1 5TUp5 Ix2 PT NAILER 8"x8" K.O. CMU BOND BM. w/ 1 - 05 BAR (1) BIMPBON BPH4 °' a A °. o ° � (__ I WALL. (REFER TO FND 4 1/2" DRYWALL CONT- (MIN LAP = 25) GROUT CELLS SOLID - VERIFY W/ FLOOR PLAN. ° TYP. ^ . " gyp.• p A A' ° '� ° °po .' p I —I-- —I FLR PLN FOR WALL THICKNESS) INSULATION OR PER ENERGY p - VERT. WALL REINF. 8"x8" PRECAST CONCRETE LINTEL °. CONT. 2X PT SOLE PLATE EMBED ACI STD. HOOK WINDOW OPENINGS BEE FLR PLN FOOTING SEE , . ° .. >.,D & o ° ;' I I�—I— 4 CONC. BLAB. IN BOND BM. #5 BAR FOR LINTEL SCHEDULE FOUNDATION PLAN FOR — — �. I _ I SEE FOUND. PLAN SIZES 4 MORE INFO. — — — �I— FOR MORE INFO. PRE GA5T CONC SILL I= —I — — — —I — I- ,- EL V O O TOP OF BLAB CURTAIN NAILER PT - Ix4 -1 WINDOWS 4 5-G.D. 05 BAR VERT, WALL REINF. CONT. 'At Q TO BOND BEAM. EMBED ACI STD. 2x6 WALLS USE SPH6 CONNECTORS IN LIEU OF BPH4 CONNECTORS SHOWN. AT 2x8 WALLS • WINDOW W/ SCREEN HOOK 6" IN BOND BEAM. GROUT USE 5PH8 CONNECTORS IN LIEU OF SPH4 CONNECTORS SHOWN. FOR WALLS LARGER THAN FOOTING SEE <.;' '; "„ ' '' " ' '' SEE FOUND, PLAN (WHERE APPLICABLE) CELLS SOLID. 2x8, USE 51MP50N 5PI'S ON EACH SIDE OF STUD TO BOTTOM PLATE 4 5IMP50N SP2'5 ON FOUNDATION PLAN " EACH SIDE OF STUD TO TOP PLATES. U.N.O," FOR SIZES 4 MORE CLEAN 4 COMPACTED SOIL. Ix2 PT FIR STRIP 6 24" O.C. 8"xl6''' C.M.U. PER A5TM C-SO (TYP.) FM�1900 P.S,L (MIN.) W/ TYPE M OR INFO. .• (95% MODIFIED PROCTOR PER ASTM D1551) 5 MORTAR PER A5TM C-210 Ix4 PT BASE NAILER INSUL. PER CALC5. 4 5PEC5 4"GONG SLAB. SEE FOUND. PLAN ELEV O'-O" TOP OF SLAB FOOTING SEE - - - FOUNDATION PLAN FOR 51ZE5 4 MORE INFO. ° 5/8" GEMENTITIDUS FINISH PER Typical Ext. Masonry Wall Section FBCR 103.1,2 CMU WALL-5EE--, PRE -FORMED • -•JOINT PLAN 4 SCHEDULE l� ♦fir ���►>�1 ��� REINFORCINGCAULKED JOINT W1 VERTICAL BACKER BAR AT MAX, PLAN FOR 51ZE 4 LOCATION) EXPOSED FACE d Example Control . D) SCALE: N.T.S. etail NOTE: SEE N-I FOR ADD ITIONAL/ALTERNATE PARAMETERS. CONTROL JOINT DOES NOT EXTEND THROUGH TIE BEAM/KO BLOCK COURSE5 K Gara a Wall Section Brn Wall S-' W/O U p I ift SCALE: NTS 24 STUDS 1/2" GYP. BOARD 24"O.C• SECURE PLATE W/ HILTI CF62 POWDER INSULATION OR ACTUATED PINS @ PER ENERGY 48 O,C. OR EQUAL CALCS./SPECS, CONT. 2X PT SOLE M1551NG ANCHOR BOLTS AT BEARING WALL: EXTERIOR BEARING WALL: IN ADDITION TO THE GENERAL PLACEMENT REQUIREMENTS: I. 5/5" DIAMETER x 6" EMBEDMENT SIMP50N TITEN HD ANCHORS SPACED A MAXIMUM OF 24'' O.C. INTERIOR BEARING WALL: IN ADDITION TO THE GENERAL PLACEMENT REQUIREMENTS: 1, 5/8" DIAMETER x 6" EMBEDMENT SIMPSON TITEN HD ANCHORS SPACED A MAXIMUM OF 48" O.C. IF RES15TING UPLIFT LOADS OR 3 1/2" EMBEDMENT AT 48 O.C, IF RE515TING GRAVITY LOADS Woad Frame To Masonry Attachment Detail Brng Wall Only SCALE: NTS 4CONC. SLAB. SEE PLATE FOUND. PLAN FOR .MORE INFO. ELkV 0'-O" TOP OF SLAB Ll — LZL r_...:._.r.. W - - - - - y SEE FOUND. PLAN ,.: N FOOTING SEE CLEAN 4 COMPACTED SOIL, FOUNDATION PLAN FOR SIZES 4 MORE INFO. (g5% MODIFIED PROCTOR PER ASTM D1551) M Garage Wall Section Non-Brn . S-1 SCALE: NTS EMBED ACI - STD, HOOK IN BOND BM. EMBED ACI - 5TD. HOOK IN FOOTING K,O. CMU BOND BEAM -#5 BAR VERTICAL WALL REINF. GROUT CELLS SOLID SEE PLAN FOR LOCATIONS %-05 DOWELS SEE PLAN FOR LOCATION LAP 25" MIN. ° ..•° FOOTING SEE FOUNDATION ,. PLAN FOR 51ZE5 4 MORE INFO. .° asonry Wall Reinforced Cell Detail y EMBED ACI ° 5TD. HOOK IN BOND BM. e ° Sx8 K.O.CUM BOND BEAM w/ 1- 15 BAR CONT. PRE-ENGINEERED CONC. LINTEL w/ 1 15 BAR CONT, 05 BAR VERTICAL WALL REINF. GROUT CELLS SOLID SEE PLAN FOR LOCATIONS ° ' DOWELS SEE PLAN FOR LOCATION LAP 25" MIN. EMBED ACI CLEAN OUT 5TD. HOOK IN FOOTING J, 0'-0" FINISHED r FLOOR FOOTING SEE FOUNDATION PLAN ,d M FOR SIZES4 MORE INFO. e•♦ ♦4. tr •°•. N ason Column Lanai/EntryDetail S-� SCALE: NTS #5 BAR TRANSITION z STEEL ACI STD, KO GMU BOND HOOK (TYP) 4 C) u- BEAM 05 BAR TRANSITION STEEL ACI 5TD, p HOOK (TYP) " ♦ Pr• Y Masonry Transifiion Defiail CELL TO BE FULL GROUTED DRILL 4 EPDXY INTO LINTEL/BONI OR CIP BEAM ABOVE WITH MINIMUM EMBEDMENT OF USE SIMP50N 5E1 HIGH STRENGTH EPDXY DRILL 4 EPDXY MINIMUM EMBEDt~ 5" SIMPSON SET EPDXY EXISTING MA5ONf BOND BEAM OR SLAB SCALE: NTS VERT. WALL REINF, `tt%111111//11, 0 +. f^ VJ o y— r — Z .. . w Lo. z .� z O.. •bra 'i+r r•••rrror•• ��0; NOTE: • M1551NG DOWELS: WHERE FOOTING DOWELS ARE PLACED INCORRECTLY OR MISTAKENLY ELIMINATED, REPLACE DOWEL AT PROPER LOCATION W/ GRADE 6O 05 BAR. INSTALL IN 5LA5 W/ 5" MINIMUM EMBEDMENT, USE 51MP50N SET EPDXY. MAXIMUM OF 3 IN A ROW 4/OR 10 TOTAL ON A PROJECT WITHOUT WRITTEN APPROVAL. • M1551NG TRUSS ANCHORS: TRUSSES WHICH ARE PLACED SUCH THAT AN EMBEDMENT ANCHOR 15 MISPLACED OR MISSING MAY BE FASTENED TO THE MASONRY BOND BEAM USING ONE 51MP60N HT5M16, MAX. CAP 15 IIIE . MAXIMUM OF 5 IN A ROW 4 10 TOTAL WITHOUT WRITTEN APPROVAL. Q TYP. Retrofit Vert. Dowel Detail S-1 SCALE: NTS TOP TIE BEAM #5 VERT. CORNER CELL FILLED W/ N I CONCRETE L 15 LAP I CONT, #5 25" LAP R Corner Continuity Detail S-1 SCALE: NTS NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND REPORT ANY DISCREPANCIES TO ENGINEER PRIOR TO 5TARTINCG ANY WORK. THESE PLANS ARE THE PROPERTY OF VORTEX ENGINEERING, LLG., AND SHALL BE RETURNED UPON COMPLETION OF THE PROJECT. USE OR COPY 15 PERMITTED BY CONTRACT ONLY. ANY CHANGES TO THESE PLANS, REGARDLESS OF WOW MINOR, WITHOUT WRITTEN APPROVAL OF VORTEX ENGINEERING, LLG, OR ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRESS APPROVAL OF VORTEX ENGINEERING, LLG SHALL AUTOMATICALLY RENDER VORTEX ENGINEERING, L.L.C. HARMLESS TO ANY LIABILITY, CLAIMS, SUITS, OR LITIGATION BY ANY INTERESTED PARTIES IN THE PROJECT. IF BOUND SPECIFICATIONS ACCOMPANY THESE PLANS, THEY SHOULD BE READ CAREFULLY FOR ADDITIONAL CONDITIONS. REVISIONS BY NEW CODE UPDATES DK/PK REVISIONS ADDED 142 MPH SHEETS DK/PK REVISIONS ADDED 160 MPH SHEETS DK/PK REVISIONS GEN NOTE REVISED DK/PK © o a w oaWz u, I- o w ZZ d EY z u POO ?zz W z� 2 000 UO, u 5 h 3gozL, V ao i - �uitZ o = N u,zo� cC 0a2Kw zz �Zm ft C-2cn -j oZ°a�oz Z LDw - QmC9 Q LD W W��GF u-, +! J O�Q a0 O zwr=� [] Lu 1]' LL =LU zzz��N LLu ZZ a maWz a Wkao =uj z'a a � F- Lb LLJ � m 0.tj- a� N O � o a M J � M kD (, Ln W M cV a- M J 00 W F-- ap 0w0 M uu N �B W R-7C00 3Ln � N o Zu'm'O LLJ Z cii°r- Lu z V) 00 0 U, L c DATE 03-rib-I0 SCALE NOTED DRAWN MK/PDK JOB _ Sheet content: Structural Details Sheet number: 51 DORMER ROOF BY TRU55 MANUF. 51MP50N MT512 a EACH TRUSS 2X12 WITH RADIUS CUT TO DESIRED PROFILE. 2X BUCKS ATTACHED W/ 3.5" EAVE DEPTH REQUIRED MIN. 1/411x 3" TAPCONS a 12" D.C. WITH MAX. 6" FROM END OF MEMBER e MA5. TYP. LOAD BEARING WALL CON5T. 6IMP60N MT515 a OPENINGS. 211x4" @ 16" O.C. (SINGLE BOTT. PLT., DOUBLE TOP PLT.) EACH TRU55 USE 51MP50N 5P2 a STUD TO TOP PLATE, 5PI STUD TO 2X MEMBERS ATTACHED BOTTOM PLATE, OR EQUALS. PROVIDE SIMPSON MT512 AT W/51MP6ON A35 WHERE NEEDED TO MEET BOTTOM PLATE TO BLOCKING BELOW (24" O.G.) MANUFACTURER'S ATTACHMENT POINT ROOF TRU55 BY REQUIREMENTS. ROOF TRUSS MANUF. TYP. 2"x4" BLOCKING AT 24" O.C. BELOW SIDE WALLS BETWEEN SUPPORTING TRU55E5 ATTACH W/51MP5ON 434 IF 1X THEN ATTACH OR EQUAL AT EACH END TYP. WINDOW THROUGH BUCK TO CMU/ WOOD SIMPSON L5TA12 AT EACH STUD TO FRAMING. IF 2X THEN BLOCKING. ATTACH TO 2X DUCK. 2-2"x4" BLOCKING WITH 4-16D OM TOENAILS 6 EACH END Q END WALL 2 P.LOAD 5 RG L ll SAL 51MP50N MT518 a BOTT. PLT., DBL TOP IF 2X ATTACH TO CMU. SHINGLE / TILE ROOF 12 PRE ENGINEERED WD TRU55 e 24" O.C. EACH TRU55 PLT.) w/ 1/4"x 3" TAPGONS - SEE ELEVATION PAGES FOR MORE SEE (TYP) ELEV. FROM END OF BUCK. INFO. FASTENING t0 BE A5 PER INSULATION PER ENERGY CALCS. 51MP50N L5TA12 EACH STUD OR EQUIV. (TYP. ALL 2X WINDOW BUCK ATTACHMENT.) MANUFACTURERS SPECIFICATIONS. 2-2"x4" BLOCKING WITH 4-16D CONTRACTOR TO HURRICANE ANCHOR EACH TRU55 SEE COM TOENAILS a EACH END PROVIDE MANUF. TRU55 SHEET FOR MORE INFO, DOCUMENTATION TO INSPECTOR TIME OF ELEVATION VARIES INSPECTION. IF 2x8 Pt VERTICAL (ARV) 6 WALL TO BE ATTACHED r F- F_ X d L IL F_ 51MP50N A35 a ALL 2X TO 2X CONNECTION POINTS. WINDOW ATTACHMENT PER MANUFACTURER'S SPECIFICATIONS WINDOW ATTACHMENT POINTS TO 2X MEMBERS OR DIRECTLY TO CMU/WOOD FRAMING ONLY. NUMBER OF DIAL. MEMBERS RELATIVE TO NUMBER OF REQUIRED ATTACHMENT POINTS PER MANUFACTURER. 2X BUCKS TO BE ATTACHED TO CMU PER 5PEC5 GIVEN IN TH15 DETAIL. 2X TO 2X ATTACHMENT TO BE 51MP50N A35. KNEE WALL ABOVE ARCH NECESSARY ONLY PER OPENING VARIATIONS. MIN, 2X BUCK FOR WINDOW/5HEATHING ATTACHMENT a TOP/SIDES OF ARCH OPENING. IF ARCH TOP PROHIBITS 2X THICKNE55 a CENTER OF ARCH, USE DIRECT ATTACHMENT TO CMU/WOOD FRAMING, WITH OR WITHOUT 1X BUCK, WITH 2X BUCK e EACH SIDE t0 EDGES OF OPENING. ALL TAPCONS TO HAVE MIN. 1-1/4" EMBEDMENT. 5PH6 CONNECTORS IN LIEU OF 5PH4 CONNECTORS SHOWN. At 2x8 WALLS USE 5PH& CONNECTORS IN LIEU OF 5PH4 CONNECTORS SHOWN. FOR WALLS LARGER THAN 2x8, USE SIMPSON 5P1'5 ON EACH SIDE OF STUD TO BOTTOM PLATE 4 SIMP50N 5P2'5 ON EACH 51DE OF STUD TO TOP PLATES. U.N.O." LINTEL. 5EE INSTALL 1/2 X 6 10" x 1/2" DIA. "J" 7/16" APA RATED SHEATHING NAIL FLOOR PLAN THREADED ROD ^~ SHEATHING NAIL BOLT @ 24" O.C. PER SCHEDULE, MIN. 16d a 6" D.G. FOR MORE INFO. 1/2 GYP. BOARD PER SCHEDULE' IN SIMPSON SET _ 114 X 3 1/2 11 NOTE: 2x8 Pt MIN. FRAMING FROM EPDXY a 2'-0" y `Or1111 Ili MASONRY SCREW "TYPICAL AT TRU55 e 16" D.C. CONT. TO IN5UL. PER CALCS, 4 SPECS O.C. (MAX) 4" GONG SLAB 2X PT SOLE PLATE POCKET a 8" O.C. ALL LOAD TOP CORD (3) 0.131 x 3 I/2" CENTERED ON ���� �(,•�• ' SEE FND. PLAN SLIDING COMMON a TRU55 CHORDS DOOR. PRECAST BEARING 5YP. UJALL. CMU WALL - SEE 2X PT 00 0.131 x 3 1/21 COMPONENTS, #1 B Structural Kneewall FLOOR PLAN FOR BOTTOM ELEV 0'-0" TOP OF SLAB CONCRETE e 4 O.C. GRADE SHALL MORE INFO. PLATE -1:z — — — LINTEL. SEE BE USED FOR NOTE: 2xc8 PT MIN, S-2 SCALE: NTS •LLJ F FOOTING SEE - FLOOR PLAN POCKET 2x4. FOR 2x VERTICAL e WALL TO �% 4 FOUNDATION PLAN k FOR MORE INFO, SLIDING DEPTHS BE ATTACHED WITH dw FOR 51ZE5 4 MORE DOOR. GREATER THAN 1/2" DIA. x 6" TITEN ,> INFO. 2x4, 12 GRADE HD. �10# •••.... OR BETTER MAY ei® �✓ P BE U5ED. ALL 4x NOTE: IX Pt VERTICAL a WALL 5P1 EACH STUD J015T RqF BOUNDARY 111 A T ical Ext. Frame Wall Section FOOTING SEE FOOTING SEE MATERIAL MAY $-2 SCALE: NITS FOUNDATION FOUNDATION BE 02 GRADE. TO BE ATTACHED WITH 1/4 x 2-1/4" tAPGON a 12" O.C. OR I I 2x8 PT R 5T .NAILING FOR PLAN FOR 4"GONG. 5LAB. PLAN FOR U.N.O." PER MAINUFACT. SPECS. WALL, DASHED SIZES 4 MORE SEE FOUND. SIZES 4 MORE lx6 HEAD LINE INFO, PLAN INFO. 4"GONG. SLAB. INDICATES 2x8 LEDGER W/ SEE FOUND. I I TOP PLATE OF 2x8 LEDGER W/ PAVERS OR PAVERS OR 4-0.131 x 3 1/2" 4-0.131 x 3 I/2" 4" GONG. 4" CONC. PLAN INSTALL GLA55 PER BLOCK WALL BEYOND WALL R.5. NAILS a PLYWOOD 0 R.5. NAILS a SLAB ° SLAB ° MANUFACTURER 1 EDGES GABLE END EACH 5TUD5 EXTEND PAST EACH STUDS ° , ° , ° (SEAMS OF TRU55 TOP FLOOR TRU55E5 HANGER TO ° � < °. 4 ° ° a4 ° _ SHEATHING) CHORD BE 51MPSON ` " '" �PRE-ENG. WOOD Q CAULK UNDER FRAME K.O. w/ 1-"5 CONT. LA LSU, ° a . °: EDGE FLOOR TRUSSES OR L55U ° HANGER TO FIEL _ PRE-ENG. BE 51MP50N PRE-ENGINEERED MIN, CONC. SILL WOOD ROOF LU5, L5U, OR WOOD ROOF C Wood Frame Pkt. Slider Detail TRU55E5 L55U MIN. TRUSSES H MU Lintel Pkt. Slider Detail I PER BCE 103.1.2 FINISH BOUNDARY PER FBCR 703.1.2 INTERIOR S 2 SCALE: NTS S-2 SCALE: NTS AREA 4" CONG SLAB :w •5 a CORNERS 48" O.G. BLOCKING 5EAM BOUNDARY ± FOR WALL, NAILING FOR PLYWOOD TO SEE FLR PLN FOR HDR. SIZE NOTE: 2x8 LEDGER W/ EXTEND TO AT 2x WALLS THAT ARE WIDER THAN 2x4 4 MAX. PANEL OVERHANG 4-0.131 x 3 1/2" R.S. INTERIOR BOTTOM OF WALL FOR ROUGH OPENINGS UNDER SIMP50N 5PH4 w/ 6-IOd WHERE THE HEADER IS NOT FULL WIDTH SHEATHING CLIP OUTRIGGER a NAILS a EACH AREA 5'-O" (1) SIMPSON G516 OR (1) NAILS EACH Iro" O.C. (CAN OF THE WALL, ADD 2x PAD BLOCKING ° <.. FLOOR TRUSS 2x8 LEDGER W/ M5TA24 w/ 22-I0d NAILS - N07 GO OVER SHEATHING) 16" O.G. RIPPED DOWN SUFFICIENT TO ".° °'°. °a FOR ROOFS (FIELD VERIFY CENTER ON HEADER U.N.O. (11 FLUSH THE HEADER TO WIDTH 4 ALLOW ° °'a a... TONGUE 4 WITH TRU55 4-0.131 x 3 1/2" NAILS EA. SIDE INTO CRIPPLE THE INSTALLATION OF THE 5PH a 4 " . GROOVE FOR FIELD FIELD SUB FASCIA OR LAYOUT R.5. NAILS a 5TUD5) (U.N.0) CONNECTORS ABOVE THE HEADER, 4 EACH STUDS FOR THE PROPER INSTALLATION OF THE FOOTING SEE ° ° ° FLOORS WALL LOCATION) CRIPPLE STRAPPING. AT 2x6 WALLS USE FOUNDATION PLAN °` a NAILING WITH -OUT FLOOR 5PH& IN LIEU OF 5PH4, AT 2x8 WALLS USE WITH FLOOR TRU55 TRU55 FOR ROUGH OPENINGS OVER SPHS IN LIEU OF 5PH4, FOR WIDER WALLS FOR 51ZE5 4 MORE a ° (PERIMETER OF 5'-O" USE (2) 51MP50N C516 U5E 5IMP50N C51(o IN AN 5PH INFO. DIAPHRAGM) OR l2) M5TA24 lUN.0) CONFIGURATION. ATTACH PAD BLOCKING G T ical Ledger Detail 51MP50N PROVIDE w/ (3) 0.131 x 3 1/2 NAILS TO HEADER MIN. L Non-Brn . Frame Down Header Detail - S-2 SCALE: NITS °2X "KING STUD L530 OR DOUBLE BOTT. U.N.O. S-2 SCALE: NTS L53 TYP. PLATE AT OPENINGS OVER WHEN NECESSARY TO MAINTAIN PROPER UItI-USe 6ffECIFICATION FOR KINGS 4 CRIPPLES 6'-2", TYP.I I CLEARANCES FOR THE WINDOW/DOOR 2X4 CROSS (THE FOLLC WITHIN AN OPENING, IT 15 ACCEPTABLE BRACING a 48" TO UPSET THE HEADER SUCH THAT ONE BRA26X4 RAT RUN • AT OPENINGS UP TO 3'-(o" (1) OR BOTH OF THE TOP PLATES 15 O.C. CI TOP RAT RUNS FOOF R 4 BRAC',ING a 46" CRIPPLE 4 (1) KING 15 REQUIRED ON FASTEN WALL ELIMINATED TO MAINTAIN THE FULL II J H 5CL.T REEL,AC;Et IENT CHART: 2X4 RAT RUN TRU55 SPANS D.C. ON TOP EACH SIDE of THE HEADER. SHEATHING a 3" DEPTH HEADER SPECIFIED IN THE PLAN • AT OPENINGS 3'-" TO 5'-2" IN SET IT 15 NOT ACCEPTABLE 70 BRACING a 48" OF BOTT. WIDTH, (2) CRIPPLES 4 (1) KING 15 O.C.ALL AROUND SUBSTITUTE A LESSER DEPTH HEADER CHORD FOR 4 OPENING • THE FOLLOWING J 5OLT5 CAN BE REPLACED UJITH THE CORRESPONDING BOLTS. O.C. ON TOP OF REQUIRED ON EACH SIDE OF THE WITHOUT WRITTEN PERMISSION FROM THE T USS 5 AN5 WHEN THE TOP PLATE 15 THE REVERSE IS NOT APPLICABLE FOR FRAME TO SLAB APPLICATION ONLI' SHEATHING ATTACHED TO EXTERIOR FRAMING PER DETAIL "0" TH15 SHEET, FRAMING ABOVE/BESIDE WINDOW PER OPENING TO MEET SHEATHING SPAN RATING5/CODE. TYP. 16" FRAMING SPACING. ALL WINDOW ATTACHMENT TO 2X BLOCKING REQUIRES ATTACHMENT OF BLOCKING TO 2X DIAGONAL W/MIN (2)10d NAILS, END NAILING TO MEMBER5FOR WINDOW/BLOCKING ATTACHMENT NOT ALLOWED. REFER t0 ORIGINAL PLANS FOR INFORMATION NOT SHINGLE IS USED, TOP PLATE SHOWN. DETAIL SHINGLE UNDEL 15 USE TO DORMER ROOF BY WITH 1/2" ANCHOR BOLT e 24" O.C. TYP. Ix4 PT BASED ON COMPLY WITH FBCR TRU55 MANUF. OR VERTICAL BELOW) a WALL TO BE ATTACHED WITH M �jener,r�I Irre ular Window Attachment INFORMATION S0511 CONVENTIONAL S x 2-I/4 TAPCON a 12 O.C. OR PER MANUFACT. S-2 SCALE: NTS CONTRACTOR. FRAME (SEE PLAN) SPECS. PROVIDED BY CMU WALL BELOW SIMPSON C516 e CORN1/2" GYP. BOARD SEE HORIZONTALLY O.C. NOTE ON N-I PAGE FOR GARAGE APPLICATION 2-2"x4" BLOCKING 51MP50N L5TA12 a EACH VARIES SEE ROOF PLAN WITH 4-16D COM STUD OR EQUIV. TOENAILS a EACH END vROOF TRU55 BY ROOF DBL. "2X" TOP PLATE TRUSS MANUF. W/ SIMPSON 5PH4 a TYP. LOAD BEARING WALL SEE TRUSS 7/16" MIN. APA DOUBLE TOP PLATE EA. STUD W/02) 10d 5EE FLOOR PLAN FOR EXACT CON5T. 2"x4 a 16" O.C. (SINGLE SHEET FOR RATED SHEATHING (MIN. STUD GRADE 5YP) NAIL5 EACH. SEE HEADER SCHEDULE (2-2X12 U.N.0) BOTT. PLT., DOUBLE TOP PLT.) TYPICAL CAL PLAN VIEW CMU WALL BELOW STRAPPING TABLE ON SHEET 5-3 FASTEN EA. STUD NOTE: FOR STUD SPACING TO TOP PLATE w/ AT 2x6 WALLS USE F Misc. Dormer Knee Wall Attachment Details SIMPSON 5P2 w/ (12) NAIL5 FASTEN HEADER S-2 SCALE: NTS SCALE: NTS PER HDR. WINDOW SEE FLOOR PLAN FOR SIZES • • FULL DEPTH DETAIL "J/52" BLOCKING a PANEL EDGES w/ SEE TRU55 SHEET 2x TOP PLATE SEE TRU55 SHEET (3) 16d TOENAILS FOR STRAPPING CONT. FOR STRAPPING — TOP CHORD EA. END SIMP5ON 5P1 w/ GYP. BOARD RETURN 10-106 NAILS EA. TRIM VARIES - SEE ELEVATIONS 7/16 MIN. A.P.A. 2x4 FRAMING (RAT RUNS) SPAN FROM STUD RATED SHTG. TRU55 TO TRU55 ON TOP OF BOTTOM FOR STUDS PRE-ENGINEERED PRE-ENGINEERED CHORD 4 BOTTOM OF TOP CHORD BELOW HDR. (2) "2X" SILL ROOF TRUSS. 2X a 16" O.C. ROOF TRUSS. (2) 0.131 x 3 1/2" COMMON NAIL5 e EA. SIMPSON 5P. 2x BOTT. PLATE PRECAST w/ IN5UL. PER ENERGY CALCS. CONNECTION 6-10dxl 1/2 NAILS 1/2" GYPEA. STUD BOARD CONT. CONCRETE PRE ENGINEERED UJOOq TRU55 • • TRU55 ENG. MORE INFO 2x STUDS e 16" O.G. NOTE: ON 16-24" PANELS DOUBLE PLYCLIP THE SIDE ADJACENT TO THE FULL WIDTH PANEL. NOT REQUIRED a RIDGE OR HIP. a 12" OR LE55 USE LUMBER ONLY BLOCKING 2"x4" FLATWI5E OR EDGEWISE ON BOTH PANEL R P HEADER. E.O.R. EDGES. BOTT. CHORD WOOD TRU55E5 ATTACHED W/ AT OPENINGS GREATER THAN 5 -2 ELIMINATED THE SPH4 CONNECTORS . NOTE : THE STRENGTH OF THE CONCRETE SHOULD BE MIN. 2F 00 PSI. SUBSTITUTION FOR 4 TRU55 2-16d a EA. IN WIDTH, (2) CRIPPLES 4 (2) KINGS SHOWN AT THAT LOCATIONS ARE NOT SPANS TRU55 JOINT ARE REQUIRED ON EACH SIDE OF PROVIDE NECESSARY. ALL OTHER STRAPPING OF "J" BOLTS WITH EXPANSION BOLTS 15 NOT PERMIITTEED. ATTACHED W/ 2X4 BLOCKING e THE HEADER. DOUBLE SILL AT SHALL APPLY AND ANY TRU55 . FOUNDATION 1PAGE TAKES PRECEDENCE. 3-0.131 x 3 1/2" 24" O/C W/ 3-0,131 x ANY DIFFERING NOTATIONS FOR OPENING . COMPONENT5 ABOVE THE OPENING GYPSUM STANDARD SCREW/NAILING ACCEPTABLE PATTERNS AND ATTACHMENTS: R.5. e EA. TRUSS 3 1/2" R.S. CRIPPLES VOR KINGS MADE ON 2 ,TYP• SHALL ATTACH DIRECTLY TO HEADER. • ALL OTHER BOLT OPTIONS MUST BE REVIEUJED APPROVED B� E.O.R. IN WRITING. • I/2" GYP. ON 16-24" O.C. WOOD STUD WALLS AND FURRED MASONRY ATTACH WITH I-I/2" GALV THE PLAN BET SHALL CONTROL. " " JOINT TOENAILS 3 EA: 51MP5a (oN SECOND FLooR) FOR RouGH ROOFING NAIL OR I-1/4 TYPE W OR 5 SCREWS a 'T O.C. ALONG ALL SUPPORTS MIN. END 51MP5�ON A34 L530 O OPENINGS UNDER 5'-0" ONLY (U SIMPSON 1/2" HIGH CONNECTOR EQ., TY C516 SPAN FLOOR SYS. TO STRENGTH OR W/4-Sd X 1 1/2" (ON CONC. SLAB) SIMPSON HTT4 5LOCKING/RUNNER5 BELOW 5/8" GYP. INTO BLOCKING W/ (1) 5/8"x8" ATR IN 51MP5ON SET 4 4-Sd X 1 1/2" EPDXY 4 (18) 16d NAILS HETA 12 a 24 O.C. (ON SECOND FLOOR) FOR ROUGH MASONRY WALL INTO TOP 2x FRAME WALL AT INTERIOR LOAD BEARING OPENINGS OVER 5' T ONLY (1)SIMPSONSET I PLATE WALLS WITH NO UPLIFT, HTT4 W/ ll) 5/S—"DREAD ROE) SET IN STRAPPING MAY UPLIFT, 51MP5ON SET EPDXY 4 (18) 1(od NAILS ELIMINATED, UNLESS EMBED A.B. 5" (MIN.) INTO MASONRY K.O. OTHERWISE NOTED BLOCK SET OR SIMPSON M5TCM60 IF FILLED CELL OCCURS BELOW "J" BOLTS TITEN HD BOLTS THREADED ROD SET IN 51MP50N SET EPDXY 1/2" x 6" 1/2" x 8" 1/2" x 5" EMBED 1/2" x 8" 1/2" x 8" 1/2" x 5" EMBED 5/8'" x 6" 5/8" x 6" 5/B" x 5" EMBED 5/5"' x 8" 5/8" x 8" 5/8" x 5" EMBED TYPICAL NAILING SCHEDULE HIGH WIND NAIL 5HEATHING BOUNDARY EDGE FIELD ROOF 0.131 x 2 1/2" R.5. RING SHANK 1/16" 4" 6" 6" WALL 0.131 x 3" COMMON COMMON 1/16" 3" 4" 6" FLOOR 0.131 x 3 1/2" COMMON COMMON 3/ " T.G. 6" 6" 12" ALL SHEATHING APA APPROVED, EXTERIOR GRADE. FOR ROOF SHEATHING, USE 2" FULL HEAD RING SHANK (0,250" MIN.) • 1/2" GYP CEILING ON 24" O.C. MAX. FRAMING ATTACH WITH 1-1/2" SCREWS At 6" O.C. ALONG EDGE AND 12" O.C. IN FIELD AT INTERMEDIATE SUPPORTS, MIN. • 5/8" GYP. ON 16-24" O.C. WOOD STUD WALLS AND FURRED MA50NRY ATTACH WITH 1-3/4" GALV. ROOFING NAIL OR 1-5/S" TYPE W OR 5 SCREWS a 7" O.C.ALONG ALL SUPPORTS, MIN. • 5/8" GYP OILING ON 24" O.C, MAX. FRAMING ATTACH WITH 1-5/8" SCREWS AT 6" O.C,ALONG EDGES AND 12" O.C. IN FIELD AT INTERMEDIATE SUPPORTS, MIN. T ical Nailin Schedules Floor Roof Wall E S-2 Ext. Wall Con. Non -Load Brn . LOcatlon SCALE: NTS T S-2 . Header Detail SCALE: NTS o S-2 SCALE: NITS NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND REPORT ANY D15CREPANOE5 TO ENGINEER PRIOR TO 5TARTIN6 ANY WORK. THESE PLANS ARE THE PROPERTY OF VORTEX ENGINEERING, LLC., AND SHALL BE RETURNED UPON COMPLETION OF THE PROJECT. USE OR COPY 15 PERMITTED BY CONTRACT ONLY. ANY CHANSE5 TO THESE PLANS, RE6ARDLE5S OF HOW MINOR, WITHOUT WRITTEN APPROVAL OF VORTEX ENGINEERING, LLC, OR ANY CONSTRUCTION EXECUTED FROM THESE PLANS AITHOUT THE EXPRE59 APPROVAL OF VORTEX ENGINEERING, LLC SHALL AUTOMATICALLY RENDER VORTEX EN&NEERIN6, L.L.C. HARMLE55 TO ANY LIABILITY, CLAIMS, SUITS, OR LITISATION BY ANY INTERESTED PARTIES IN THE PROJECT. IF BOUND SPECIFICATIONS ACCOMPANY THESE PLANS, THEY SHOULD BE READ CAREFULLY FOR ADDITIONAL CONDITIONS. REVISIONS BY NEW CODE UPDATES DK/PK REVISIONS ADDED 142 MPH SHEETS DK/PK REVISIONS ADDED 160 MPH SHEETS DK/PK REVISIONS GEN NOTE REVISED DK/PK ui o n o wmw - F 6<'23 LLI a z Ei0 w La, r=U; u. 3soQ� U z 5 rn-I aE0. >jU LUK w°�z�Uoac�O0 N H u.:�. Q zr QW J zzuz �z 00 .co0w N ZviZ 7 �. j L�oS'wLL d wywQ ` U_ y7 tr0 3 w w U (9Z <Lu L) (9w.CwjJ Q Z Q = a�9 w2W acL miuW.x =a�wlL (N cr $ o a JM —� Oo M L w m d M N N Ln M W F- p 0000 M 00 w N �M L N �R*0 3:Ln -j N C9 Z �- � ¢ z MO oc e-I U °° " X a �- a W g vi a Ora > a 0 /e U)ee e Oix� e DATE a3-aS-18 SCALE NOTED DRAWN MK/PDK JOB - Sheet content: Structural Details Sheet number: 52 0.131 x 3" COMMON SEE TABLE FOR NAILING 4 5Ar OR 6'-0" M/N. 16" c.c. SCHEDULE 6 SPLICE 4-10.131 x COM. DOUBLE TOP PRE-ENG WOOD TRUSS (TYP) 4-0.131 x 3" PLATE RAT pSEE COMMON aaa as 3-0.131 x 3" COMMON DOUBLE STUD EA. 51DE OF JOINT 0.131 x 3 SAPA HE T 4-0.131 x 3 1/2 COM. NAILING 5CHEDULE TABLE FOR �� COMMON 6 16" o.c. 5TUD5 6 16" c.c. PT BOTT. -'/ ATTACHMENT. U.N.O. 4 / PLATE / 2-0.131x3" ` 3 COMMON / , 2-0.131 x STRAPP50NOCTAI2 zi�U55 2x4 BLOCKING (1) 51MP5ON L5TA12 1/2" CEILING GYP BD W/ 5d 5 / .� 3 1/2' GOM. 2-0.131 x 3 1/2" OTTOM ATTACHED W/ (TYP) OR COOLER NAIL5 7O.C. OR �, COM. (1) 51MP50N LTA2Z 48 O.C. ATTACHED CHORD (2) 0.131 x 3 PROVIDE 2x4 W/ EQUAL, DIAPHRAGM AREA 1/2 TOENAILS 0.131 x 3 1/2 NAIL5 (4 BAY OR 8 ft FROM S " SEE TABLE BELOW DOUBLE 5TUD CONDITION TO BOTTOM CHORD EACH END, Q (o" O.G. MASONRY WALL) 1 FOR LAPSPLICE OF GABLE UNO. CONTINUOUS 1/2" GYP BD NOTE: CRO55 BRACING 4 2 8" MA50NRY WALL W/(I) 05 REBAR /-/1A It IAI t 1 ALL BLOCKING TO BE A 1-I Y' � �AtI Yrlh I2KF��dT�'1'� 901 nr. TYP a Al I 3 5-0,131 x 3 1/2" TOP FLATE 45TENERS 2-0.131 X 3 � I -LAN 1. IIv - M_H Iyl� (iH I HI=VICHI- , .w ►, _ _. ,. I COURSE E Expanded BlockingInformation Dia ram 8-3 SCALE: NTS �,� 1-_ --- 3 - -- - - - - TOP PLATE FASTENER 5CHEDULE (EXTERIOR WALL) / DOUBLE 0131 x 3 1/2" COM. f TOP PLATE 1611 O.c. 3-0,131 x 3 � f 2-0.131 x 3 1/2'' COM. 1/2 COM. O LAPSPLICE NAILING 0 SPLICE ALL OTHER NAILING 2-ROW5 0.131 x 3" Is 3" O/C 0.131 x 3" 6 8" O/C \%-,� - SECURE RIDGE BEAM TO CLEAT U1/ I //�'\� �, PT BOTT. PLATE APA RATED SHEATHING. 5EE NAILING 5CHEDULE TABLE FOR ATTACHMENT. (4) 16d TOENAILS EACH SIDE �- - 2x4 COLLAR TIE MID -HEIGHT � 4 RAFTER PROVIDE (5) I(od NAIL5 EA ENE) TOP PLATE FA5TENER 5CHEDULE (INTERIOR WALL) 4 STUD CORNEA' SINGLE 5TUD CONDITION (1)51MP50N M5TA36 RUNNING ALONG THE EXTERIOR SIDE LAPSPLICE NAILING 6 SPLICE ALL OTHER NAILING 2411 2 ROWS 0.131 x 3" Q 6" O/C 0.131 x 3" 8" O/C CONTINUE SHEATHING BELOW VI 1 r,�._ �I I "_ 11_ AT CORNER. MAY 2x4 'IT" BRACE CONVENTIONAL FRMG a ATTACHED STRUCTURES WHICH ARE ONLY IN LOCATIONS WHERE A PIPE PENETRATES THE TOP PLATE OF A THING. APPLIED OVER SHEATHING. OR L5TA12 PREFAB ROOF PARTIALLY ENCL05ED SUCH A5 A BEARING WALL, USE THE FOLLOWING PLATES: 0.131 x 3" COMM. . 16" O.C. TRU55E5 - ENTRYWAYS $ PORCHE5 - P5PN58Z IN LOCATIONS WHERE A LAP 5PLICE 15 OVER 16" AWAY II 24 O.C. - PSPN51�oZ IN LOCATIONS WHERE A LAP SPLICE 15 WITHIN 16" i PRE-ENGINEERED OVERLAP TRU55 BRACING �0� 5: WOOD TRU55E5 LEAST ONE TRU55 5PACE 41-oI1 4111 -o 12d COM. 6 6" OVERLAP ° 2x4 BLOCKING ATTACHED I/2" CEILING GYP BD w/ 5d I. ALL RAFTERS SHALL BE 112 SOUTHERN YELLOW PINE 6 24" O.G. MAX. SECTION 51ZE SHALL 12" O.C. 4-16c1 COM. w/ (2) 0.131 x 3 I/2" TOENAIL5 COOLER NAIL5 7" O.C. OR BE DETERMINED ACCORDING TO THE LENGTH OF SPAN A5 FOLLOWS: 2-5d GOM. 51MP50N 5PH4/6/8 EACH END (UN.D.) EQUAL, DIAPHRAGM AREA (4 BAY UP TO 4'-0"---- 2X4 12'-0" TO 15'-0" ---- 2XlO UNLE55 NOTED AT A OR 51MP50NOTHERWISE, SDWC15600 FROM OR 8 FEET FROM MA50NRY WALL) 4'-0" TO 8'-0" ---- 2X6 15'-0" TO 18'-0" ---- 2X12 `° �' 2-2"x4" W/l/2" PLYWD. MINIMUM ALL STUD TO TOP 8'-0" TO 12'-0" ---- 2X8 SPACER NOTE: 2X4'S UN5PECIFIE1) FRAME PLATE Gable Diaphragm Side Wall °� MAY BE TURNEDTO F 2. RIDGE BEAM SHALL BE #2 SOUTHERN YELLOW PINE. SECTION SIZE SHALL BE 2" (NOMINAL) , � FLATWISE 50 NO CONNECTIONS SHALL S-3 (For Illustration Only) SCALE: NTS LARGER THAN RAFTERS W/ A MAXIMUM RIDGE SIZE OF 2xI2 FOR 2x12 RAFTERS. 5PACER 15 NEEDED. �16COM. 8" O.C.. CONSIST OF (3) 0.131"X3-1/2" END 0.131 x 3 1/2" COM. 8" O.G. 3. CLEAT SHALL BE A "2 SOUTHERN YELLOW PINE 2x10. IT SHALL BE FASTENED AS SHOWN W/ 1Od COM. 12" o.c. NAIL5 OR TOENAILS. APA RATED SHEATHING. SEE SIMP5ON M5TA24 TENSION 5TRAP5 a EACH TRU55 U51NG (14) 10d NAIL5. INSTALL THE 4 -16d COM. SEE NAILING NAILING SCHEDULE TABLE FOR 2x4 DIAGONAL ATTACHED [ATTACHMENT. STRAP BY CUTTING A HOLE INTO THE SHEATHING 6 EACH 5IDE OF TRU55 $ THREADING *A SIMPSON MSTCM 60 5CHEDULE TABLE U.N.O. W/(4) 0.131 x 3 1/2" NAIL5 e THE U-SHAPED STRAP FROM BOTTOM OF TRUSS TOP CHORD TO TOP OF CLEAT. INT. NE 4DER (NON -BE gRINC� MAY BE 5UB5TITUTED FOR 51MP5ON HTT4 W/ FOR ATTACHMENTSINTERSECTING BLOCKING AN HTT4 WHERE LOCATION 5/6" DIA A.B.* 4. SECURE RAFTERS TO CLEAT 4 WRAP TO TOP CHORD USING 51MP6ON HT520 W/ ( 20) 10d ALIGNS WITH A FILLED 1-0 NAIL5 NAILS FOR 2x12 RAFTERS, (16) 10d NAILS FOR 2x10 RAFTERS, (14) 10d NAIL5 FOR 2x6 CELL. MINIMUM (2) 0.131 x 3 1/2" MINIMUM 1"X4" TRU55 M4x RAFTERS WITH 6PAN5 OF 4'-0" OR GREATER. 2x6 RAFTERS W/ 5PAN5 LE55 THAN 4'-0" PER JOINT BRACING APA RATED SHEATHING. RE -ENGINEERED SHALL BE TOE -NAILED TO CLEAT W/ (8) 106 NAIL5. SEE NAILING SCHEDULE o TRU55E5 6 24" O.G. 5. SECURE RAFTERS TO RIDGE BEAM USING 51MP50N L55U210 SLOPING HANGER W/ (10) 10d p General Wood Attachment Details 5TUD CORNER Truss Bracing Overlap Detail TABLE FOR ATTACHMENT. U.N.O. /2" CEILING GYP BD W/ 5d NAIL5 INTO RIDGE BEAM 8 (1) 106 x 1 1/2 NAILS INTO 2x12 RAFTERS. USE (5) 10d $ (6) 10d RESPECTIVELY FOR 2X10 RAFTERS. USE L55U28 W/ (10) 10d 4 (5) IOd x 1 1/2'' FOR 2x8 S-3 SCALE:NTS STRAPPING INFORMATION q $-$ SCALE: NTS COOLER NAIL5 7" O.G. OR EQUAL, DIAPHRAGM ARE (4 BAY OR 8 RAFTERS, USE 1_506 W/ (6) 10d 4 (5) IOd x 1 1/2" FOR 2x6 RAFTERS WITH 5PAN5 OF 4'-0" ft FROM MA50NRY WALL) OR GREATER. 2x(o RAFTERS W/ SPAN5 LE55 THAN 4'-0" MAY BE TOE -NAILED TO RIDGE (1) 51MP5ON L6TA12 STRAP 48" O.G. BEAM W/ (8) 10d NAIL5. 6. WHERE NEEDED, PROVIDE FLAT 2X6 BLOCKING BETWEEN TRU55E5 AT TOP CORD FOR INTERIOR VOLUME SEE FLOOR PLAN FOR (1) 51MP5ON HETA20 SEE 2x4 BLOCKING ATTACHED UJ/ (2) INSTALLATION SUPPORT OF M5TA24 5TRAP5. SECURE BLOCKING W/ (3) 16d TOENAILS AT EACH END INTO TOP CORD. AREA �.• ..! LENGTH $ WIDTH 48" O.C. ATTACHED TO BOTTOM CHORD OF EXPANDED 0.131 x 3 1/2" TOENAILS EACH END, BLOCKING UND. Valle Set Attachment Detail �� •. '� • (U MSTA3O AT EVERY .. O• DBL TOP PLATE FASTEN CAP TO CHA5E w/ �0:131 x 3 1/2" R.5. NAIL5 0 12" GABLE DETAIL (TYP) FLAT OR CATHEDRAL � S-3 SCALE:NTS PRE-ENGINEERE PRE-ENGINEERE �� OTHER 5TUD (32 O.C. .. :w MAX.) FROM UPPER STUD = rTO O.C. ALL-AROUND O.C. 8" MASONRY WALL W/(1) #5 1/2" GYP BID WOOD ROOF TRU55E5 WOOD ROOF TRUSSES LOWER TOP PLATE,�" +.�' KNEEWALL INSTALL 6IMP50N LU524 REBAR CONT. IN a°. KNOCKOUT COURSE NOTE: CRO55 BRACING INTERIOR WRAP TOP PLATE A5 op NEEDED FOR FULL ;, , '• •' WALL SHEATHING NAILED PER ALL BLOCKING TO BE REPEATED 48" O.C. TYP. 5TUD5 MIN. MIN. EA. SIDE OF THE CEILING JOISTS. JOISTS ALL RAFTERS SHALL BE *2 PLYWOOD TO EXTEND TO VOLUME AREA • NAILING. IF 5TUD5 ALIGN �i e 6' STRAP SHALL EXTEND � d eee� ••• 0'/5-2 DBL 2X4 16" O.C. TO BE PER NOTE al SOUTHERN YELLOW PINE 0 24" O.C. MAX. SECTION SIZE SHALL BOTTOM OF WALL INSTALL (1) M5TAM24 AT EVERY STUD (16" STRAP EACH FROM UPPER STUD TO i/ 11I PLATE CONT. 'a V-0" (MAX.) TYP. Masonry Gable End BE DETERMINED ACCORDING O.C. MAX.) EMBED STRAP TRUSS (SEE PLAN) LOWER STUD. u- W/ 51MP50N G $_3 SCALE: NTS TO THE LENGTH OF SPAN A5 FOLLOWS: AT EACH TRUSS Extended Bottom Chord Attachment Details } HT520 � 32° s 2X4 WE) CONST. w O.C. OR G516 TO ALIGNING FLASHING ALL-AROUND UP TO 4'-0" ---- 2X4 4 -O TO 8 -O ---- 2X6 S-3 SCALE: NTS e 16" O.C. w w 5TUD5 BELOW SADDLE SEE NAILING APA RATED SHEATHING. SEE NAILING ATTACH THE CEILING FRAM 8'-0" TO 12'-0" ---- 2X8 WITH (4) 0.131 X 3-1/2" NAIL5 n 2x6 50LE PLATE- ROOF ELEMENT SCHEDULE TABLE FOR SCHEDULE TABLE FOR ATTACHMENT. U.N.O. TO EA.. STUD ALL AROUND 12'-0" TO 15'-O" ^--- 2X10 CUT OUTSIDE EDGE ATTACHMENTS PERIMETER. IF ABUTTING 15'-0" TO IS'-0" --- 2X12 MASONRY USE P.T. 5YP 02 NOTES: I. ADJACENT NAIL5 ARE PLUMB TO ALLOW SOLID CONNECTION C5 16 TOP 2x4 DIAGONAL LEDGER AND ATTACH TO DRIVEN FROM OPPO51TE 51DE5 OF THE COLUMN w/ SHEATHING FASTEN TO ROOF SHEATHING CHORD TO CHIMNEY APA RATED ATTACHED W/(44) 0.131 x I -p" 3 1/2" NAIL5 w MASONRY W/ 1/4" DIA. X 3" TAPCONS 6 6" O.C. MAX. NOTES : 2. ALL NAIL5 PENETRATE 4C4 / BLOCKING w 1/4" x 5" WOOD 5CREWS 6 4'1 EA. CORNER SHEATHING. SEE NAILING SCHEDULE M4X INTERSECTING BLOCKING 1. ALL CEILING FRAME TO BE AS PER TABLE LEAST 3/4 OF THE THICKNESS OF THE LAST = _N m m ° O.G. ALL-AROUND TOPCHORD ENG. TRUSSES a 24: O.G. TABLE FOR ATTACHMENT. U.N.O. S 'a 2. FOLLOW NAILING PATTERN FROM THE APPROVED PLANS FOR SHEATHING LAMINATION 3. FOR 4-PLY, PROVIDE I/4 ° (1) 51MP50N L5TA12 1/2" CEILING GYP BD W/ ATTACHMENT. 3. WHEN INSTALLING SIMP50N PRODUCTS REFER DIA. X 5 1/2" LAG SCREWS OR EQUAL EACH END OF "L" 5d COOLER NAIL5 7" O.C. OR EQUAL, DIAPHRAGM TO 51MP50N'5 INSTRUCTIONS 4 (5PACE AS SHOWN FOR ROOF SHEATHING 2x6 BLOCKING FASTENED TO FRAMING w 4.0.131 x 3 1/2 BRACE AREA (4 BAY OR 8 Ft FROM MASONRY WALL) 6PECIFICATION5. 4, ALL LEDGERS TO BE 2X 5YP "2 AND SAME T Frame Down CI 3-PLY) 4. FOR 5-PLY, PROVIDE 1/4" PIA• X 7" LAG SCREWS ° NAIL5 EACH END 2x4, 2x6, OR 2x8 M , . DEPTH AS RAFTERS (PT AT MA50NRY CONTACT), EQUAL (5PACE A5 I ' O.C. SEE FLOOR S-3 SCALE: NTS SHOWN :FOR 3-PLY) SHOWN Fire lace Chase Detail PLAN FOR SIZING OF 5TUD5 PRE-ENGINEERED TRU55E5 a 24" O.C. FLAT OR CATHEDRAL 5. REFER TO NDI SECTION 15.3 FOR ADDITIONAL 0 -„ I �II S-3 SCALE:NTS 2x BLOCKING e ALL (1) 51MP50N HIOA OR HT516 SHEATHING 6EAM5, USE EDGE NAILING SCHEDULE, NOTE: CR055 BRACING 4 APA RATED SHEATHING. SEE NAILING ALL BLOCKING TO BE BRACING PER TRUSS-\ SCHEDULE TABLE FOR ATTACHMENT. TYP. Frame Wall Gable End REPEATED 48" O.G. TYP. O N.. H ENGINEERING U.S-3 SCALE: NTS M4X PRE-ENGINEERED APA RATED APA RATED SHEATHING SEE NAILING NOTES: INFORMATION ° "TYPICAL AT ALL LOAD COMPONENTTS"LUMBER TYPE AND GRADE MAY FOLLOW TH15 TABLE FOR ITS GIVEN OPTIONS." LUMBER DEPTHS (2) 2"x LAMINATIONS (3) 2"x LAMINATIONS (4) 2"x LAMINATIONS ATTACH LARGER THAN 2X6 MAY ATTACH w/ 0.131 x 3'1 ATTACH w/ (2) ROWS OF w/ 5IMP50N 5D525600 WOOD BE 5U55TITUTED FOR R.5. NAIL5 0.131 x 3" R.5. NAIL5 6 6" 5CREW5 5TAGGERED e 6" ANY STUD WORK AT 16" 5TAGGERED a (o" O.G. O.C. ALONG THE LENGTH O.C. ALONG THE LENGTH OF OC MAX. SPACING (02 ALONG THE LENGTH OF THE COMPONENT, FOR THE MEMBER, FOR 5YP MIN.)" OF THE COMPONENT COMPONENT5 WIDER THAN COMPONENTS W" WIDER THAN 8 SHEATHING. SEE TRU55E5 6 24'' SCHEDULE TABLE FOR ATTACHMENT. 8 USE (3) ROWS. USE (2) ROWS 6 O.C.. sagLE o EDULE D.C. u.N.o. N 142 mph MAX. Ex . G, Enclosed, Exterior Frame Wall Table Q T Nailin Schedule for Built-U Columns &BEAMS ATTACHMENT. U.N.O. SEE DETAIL A S'3 SCALE: NTS NOTE: THREE OR S-3 SCALE: NTS CN TH15 SHEET OMPRE65ION WEB DROPPED (iYP) MORE REPEATED SLOPING OR GABLE END FOR IDENTICAL TRU55E5 10-Ro VERTICAL SEE EXPANDED OUTRIGGER SHALL HAVE WHEN TRU55 STUD ARE NOTE: CONTINUOUS 20'-011 20'-0° BLOCKING ALIGNED 51MP50N TWIST BOTTOM CORD DIAGONAL BRACES. STRAP TYPE CONNECTOR 1. SEE TRUSS DIAGRAM BRACING 1X4 -- - ----�� UNBRACE WALL HE IGHT a2 5YP 8'-0" 2x4 e 16" c.c. 8'-811 2x4 16" c.c. 9'-O" 2x4 16" o.c. 9'-4" 2x6 e 16" o.c. 10'-011 2x6 e 16" c.c. (1) 51MP5ON 2x4 BLOCKING 1/2 CEILING GYP BD W/ L5TA12 STRAP ATTACHED W/ (2) 5d COOLER NAIL5 7° (A5 REQUIRED B1' ONTINUDUS PERMANENT LATERAL (HT5/MT5) MAY BE t L4NUF-4CTURER'S MIN. 48" O.C. 0.131 x 3 1/2" R.5. O.C. OR EQUAL, BC51) BRACE (CLB) NAILED TO TRU55 6 5TUD BELOW. NO 5PN4 15 WHEN 5TUD 15 TRU55 ENGINEERING CUT SHEETS FORTOENAILS EACH DIAPHRAGM AREA (4 END, UNO. BAY OR 8 ft FROM NEEDED THIS 5TUD. NOT ALIGNED ADDITIONAL WETA 2O 48" O.C. MA5ONRY WALL) ATTACHED TO 1/211 GYP BD ERMANENT DIAGONAL BRACE 9 WITH A TRU55 NOTE: (/ °° AND/OR WHEN "AT PERMANENT BRACING CLB DIAGONAI_- BOTTOM CHORD OF FLAT OR CATHEDRAL 1/2" CEILING NAILED TO OPPOSITE SIDE OF WEB 2x6 WALL5 USE 5PH6 TRU55 STRAP 15 TH,4T MY BE REQUIRED. BRACE A5 GABLE GYPSUM BID TO PREVENT LATERAL MOVEMENT d SHOULD BE REPEATED CONNECTORS IN LIEU OF ° ° ° NOT DIRECTLY 5PN4 CONNECTOR5 SHOWN. ° ° ° ° ATTACHED TO 2 'IT" BRACING M,4Y SE REQUIRED BY 4. NOTE: CR055 BRACING :., APPROXIMATELY 20' INTERVALS. AT 2x8 WALL5 USE 5PH8 STUD USE (1) USED IN PLACE OF 5C51 8" MASONRY WALL ALL BLOCKING TO BE CONNECTORS IN LIEU OF 51MP5ON 5PN4 1 ERM,4NENT 5R,4CING W/0) #5 REBAR CONT. REPEATED 48" O.C. TYP. Ix4 MIN. BRACING W/(3) 0,131 x 5PN4 CONNECTORS SHOWN, OR SP2 PROVIDED IT EXTENDSLU IN KNOCKOUT COURSE 3 1/2'' NAIL5 e INTER5ECTING FOR WALLS LARGER THAN OVER � LE:AST 9P�°ro OF WEBS ZxB, USE 51MP50N 5P1'5 ON EACH 515E OF STUD TO TYPICAL HIOA CONFIGURATION, p0 NOT NAIL TO THE UJEB, B OTTOM PLATE 8 SI � THROUGH OTHER STRAPPING/CONNECTOR5. °° REFER TO CONNECTOR NOTES FOR FRAME TO 50TT ON EACH SIDE OF °° TRU55 CONNECTIONS. F G bl I Th CLB Dia onal Brace 201.May Intervals Detail 5TUD To TOP PLATES. Q u�1 !ll �--- TOP 8 BOTTOM CORD - C Gable Section - or a e ess an U.N.O.'' - S-3 1 11 S"3 SCALE: NTS 4 -0 High SCALE: NTS NOTE: SEE TRU55 LAYOUT GABLE END. BRACING FOR ANY ADDITIONAL a Frame Wall Truss Connection Detail R Gable & Clg Bracing Diagram 4'-011 C.C. MAX. FOR FIR5T STRAPPING REQUIRED S-3 SCALE: NTS s 3 SCALE: NTS (4) ROWd OF TRU55E5 .�IwoA �' 1010110a�a xe 111011111 MIN NEW MIN NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND REPORT ANY DISCREPANCIES TO ENGINEER PRIOR TO 5TARTING ANY NORK. THESE PLANS ARE THE PROPERTY OF VORTEX ENGINEERING, LLG., AND SHALL BE RETURNED UPON COMPLETION OF THE PROJECT. USE OR COPY 15 PERMITTED BY CONTRACT ONLY. ANY CHANGES TO THESE PLANS, REGARDLESS OF HOW MINOR, WITHOUT WRITTEN APPROVAL OF VORTEX ENC71NEERING, LLC, OR ANY CONSTRUCTION EXECUTED FROM THESE PLANS NITHOUT THE EXPRESS APPROVAL OF VORTEX ENGINEERIN6, LLC SHALL AUTOMATICALLY RENDER VORTEX ENGINEERING, LLC. HARMLESS TO ANY LIABILITY, CLAIMS, SUITS, OR LITIGATION BY ANY INTERESTED PARTIES IN THE PROJECT. IF BOUND SPECIFICATIONS ACCOMPANY THESE PLANS, THEY SHOULD BE READ CAREFULLY FOR ADDITIONAL CONDITIONS. REVISIONS BY NEW CODE UPDATES DK/PK REVISIONS ADDED 142 MPH SHEETS DK/PK REVISIONS ADDED 160 MPH SHEETS DK/PK REVISIONS GEN NOTE REVISED DK/PK A O Wp LLJ 1-Z O ZO w O2 Z w ci owuF F8OQ2 LV "O F B a >. 0. 3 w LL�u b GL 2r_u 2Zin eI QQ ZCQZ �YOy ccr enZoe =��Z p�oZ-e�az ~ .>- aa�° z Z w F� � i�ea2Zw 0 O -' cc o o Wa°aa� L- 3 �o O zwzz=- 0 W LL V ZZZviV)i LIJ Z >tJ Wl7 w� .J Zz =W��F Q H �< i Q w w W V In a ova 0 a Udf M -oM C� Ln w �� Z (-4 am, 00 'd' Ln �q U5 1= p 00 InW ; f V W d' O � Ln ,,AA r N z LL� Y V Q CI Z M O OLU o uu ¢ �00 QLL � g vi a 0 eee s cc: ¢ .. • ,. co 0 L DATE 03-OB-/LS SCALE NC7'5D DRAWN MK/P©K JOB - iheet content: Structural Details Sheet number: 53-142 DBL. 2 x 4 TOP PLATE 51MP50N 5PN4 a EACH STUD TO TOP PLATE WALL CONNECTION W/0 WINDOW NOTES: 1. WHEN WALL 15 PARALLEL TO FLOOR 5Y5TEM 5TRAP TO TOP 4 BOT, CORD OF TRU55, 5IMP50N L5TA30 w/ 22 -10d NAILS a 24" O.C. MAX OR EACH STUD. 2. PROVIDE 2X BLOCKING a 5EAM5 8 RUN SHEATHING CONTINUOUS TO TOP OF MASONRY. (SEAM 16" MIN. ABOVE 2ND STORY FINISHED FLOOR.) INSULATION PER ENERGY CALC5. 3. ALL WALL5 TO BE CONSIDERED SHEAR RE516TING COMPONENTS SEE ELEVATION PAGES ROOF COVERING 8 SHEATHING DETAIL SEE ELEVATION --- PAGES FOR SOFFIT 4 FASCIA DETAIL WD. HEADER (U.N.O.) SEE FLOOR PLAN FOR EXACT SCHEDULE Sol ELEVATIONS WINDOW SEE FLOOR PLAN FOR 51ZE5 INSULATION PER COMMUNITY 5PEC5 OR ENERGY CALC5 1/16 APA RATED SHEATHING MIN., NAIL PER SCHEDULE DETAIL ''0'' ON SHEET 5-2 2 x 4 50LE PLATE 5IMP50N C516 OR 5IMP50N — M6TA36 a 32" O.C. OR EVERY OTHER STUD, TYP., BLOCK A5 NEEDED 2x4 1*2 5YP RIM w/ (5) 0,131 x 3 1/2" NAIL5 EA. TRUS5 J015T (INSET) 2x4 FLATWI5E VERT. BLOCKINEr— AS NEEDED TO ACHIEVE FULL NAILING IN 5TRAP5, 2x4 12 5YP RIM w/ (5) 0.131 x 3 1/2" NAIL5 EA. TRU55 J015T (INSET) SHEATHING TO BE FLUSH W/ BLOCK 5EE TRU55 LAYOUT FOR 5TRAPPING INFORMATION 8" CONC, K.O. BLOCK BOND BEAM POUR SOLID W/ 1 - S REBAR CONT. HORIZ. MIN. LAP = 25" WINDOW SEE FLOOR PLAN FOR 51ZE5 WIND RE515TANT PRE-C,45T CONIC. SILL 4" HIGH CONC. BLK. 8" CMU PER A5TM-C 90, 1900 P51 MIN. W/ TYPE M OR 5 MORTAR PER ASTM-C 210. 5/8" CEMENTITIOU5 FINISH PER FBCR 10301.2 NOTE: "AT 2x6 WALL5 USE 5PH6 CONNECTORS IN LIEU OF 5PN4 CONNECTORS SHOWN. AT 2x8 WALLS USE 5PH8 CONNECTORS IN LIEU OF 5PN4 CONNECTORS 5HOWN. FOR WALLS LARGER THAN 2x8, USE 5IMP50N 5PI'5 ON EACH SIDE OF STUD TO BOTTOM PLATE 8 51MP5ON 5P2'5 ON EACH SIDE OF STUD TO TOP PLATE5. U.N.O." ENGINEERED ROOF TRU55E5 624" O.G. MAX. 12 SEE ELE INSULATION BAFFLE INSULATION PER COMMUNITY 5PEC5 OR ENERGY CALCS 1/2" GYPSUM CEILING BOARD HURRICANE ANCHOR a EACH TRU55 SEE TRU55 LAYOUT FOR STRAPPING INFORMATION DBL. 2 x 4 5YP TOP PLATE W/ SIMP50N 5PH4 a 16" O.G. EACH STUD (12) 106 NAILS EACH. GYP. BOARD RETURN WINDOW SILL CAULK a WINDOW 2 x 4 SILL \ '--- DBL. 2 x 4 TOP PLATE 5IMP50N 5PN4 a EACH STUD TO TOP PLATE WALL CONNECTION W/O WINDOW SEE ELEVATION PAGES FOR 50FFIT 4 FASCIA DETAIL (2)-2x WD. HEADER (U.N.O.) W/ 1/2" FLITCH PLATE SEE FLOOf PLAN FOR EXACT SCHEDULE WINDOW SEE FLOOR PLAN FOR 51ZE5 SEE ELEVATION PAGES FOR ROOF COVERING 6 SHEATHING DETAIL all ELEVATI ENGINEERED ROOF TRU55E5 a24" O.G. MAX. 12 I E�E INSULATION BAFFLE INSULATION PER COMMUNITY SPECS OR ENERGY CALC5 1/2" GYPSUM CEILING BOARD HURRICANE ANCHOR a EACH TRUS5 SEE TRU55 LAYOUT FOR 5TRAPPING INFORMATION DBL. 2 x 8 5YP TOP PLATE W1 5IMP50N 5PH8 e 16" O.G. EACH STUD (12) 106 NAILS EACH. GYP. BOARD RETURN WINDOW 51LL CAULK a WINDOW 2 x 8 SILL INSULATION PER 2X FRAME WALL SEE TABLE COMMUNITY 5PEC5 OR ENERGY GALCS 2X FRAME WALL SEE TABLE "N" ON SHEET 5-3 FOR "N" ON SHEET 5-3 FOR SPACING. 5PACING. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD 1/16" APA RATED SHEATHING 3/4" T4G GLUED W/ CON5TR. ADHESIVE NAIL PER SCHEDULE DETAIL 4 NAILED SEE SCHEDULE DETAIL "0" 0 ON SHEET 5-2 ON SHEET 5-2 PRE ENGINEERED WOOD FLOOR TRU55E5 a 24'' O.C. IN5TALL 1/2" DIA. x 8" "J" 5OLT5 4 WA5HER5 W/ 5" IMBED a 2'-0" O.C. (MAX.) CENTERED ON WALL. USE DOUBLE KO BLOCK COUR5E5 WITH 51MP60N 5PH8 2-05 BARS CONT. IN EACH. (NOTE: FOR LOCATIONS WHERE THE HORIZONTAL OPEN DISTANCE (UNBRACED LENGTH OF MASONRY WALL TOP) 15 LESS THAN OR EQUAL TO 6'-6" AND DOUBLE a 2x8 PT SOLE PLATE .�,.• .•.. �.� /��� COURSE 5HOWN 15 NOT NOTED AT THE Z**� � �- 51MP5ON HETA20 a 32'' O.G. IF ©� `il =� ATTACHED TO RIMJ015T5. 624" O.C. MAX IF ATTACHED TO FLOOR FLOOR PLAN, IT IS ACCEPTABLE TO USE A SINGLE KO BLOCK COURSE WITH 2-05 ~ `" IX P.T. FURRING HORIZ. = 1 w � 0 �'• . Q TRU55E5 BAR5 CONT. IN LIEU OF THE DOUBLE Q �. ;v Q •44 1/2" CEILING GYP. BOARD SEE COURSE SHOWN IN TH15 DETAIL.) NOTE ON N-1 PAGE FOR SPECIFIC NOTATIONS ON FLOOR PLAN SHALL CONTROL. ,•.•. ••. ��� .. �, . GARAGE APPLICATION •••.• � IX P.T. FURRING HORIZ. 8" CONIC. K.O. BLOCK BOND BEAM POUR SOLID (2500 PSI) �11111� W/ 2 - S REBAR CONT. HORIZ. MIN. LAP = 25'' 1 x 6 P.T. CURTAIN NAILER 6 OPENINGS 1 x 6 P.T. CURTAIN NAILER a OPENINGS PRECAST CONCRETE LINTEL PRECAST CONCRETE LINTEL SEE FLOOR PLAN FOR SCHEDULE SEE FLOOR PLAN FOR SCHEDULE I x P.T. BUCK STRIP I x P.T, BUCK STRIP a < ' da . 4 a WINDOW SILL - CAULK a WINDOW 1/2" GYPSUM BOARD 4"GONG, SLAB. SEE FOUND. PLAN FOOTING SEE FOUNDATION PLAN FOR 5125 4 MORE INFO. A Typical Two Story Wall Section S 4 SCALE: NTS WINDOW SEE FLOOR PLAN FOR SIZES WIND RESISTANT PRE -CAST CONC. 5 1 L L 4" HIGH CONC, BLK. 8" CMU PER A5TM-C 90, 1900 PSI MIN, W/ TYPE M OR S MORTAR PER ASTM-C 210. 5/8" CEMENTITIOU5-------.— FIN15H PER FBCR 103.1.2 WINDOW SILL - CAULK a WINDOW 1/2" GYPSUM BOARD 4"GONG. SLAB. SEE FOUND. PLAN $ FOOTING SEE a a 4 FOUNDATION PLAN FOR SIZE5 & MORE rc--jypical Two Story Wall Section sa W/U Floor. System SCALE:NTS NOTE: CONTRACTOR TO VERIFY ALL DIMEN51ON5 IN FIELD AND REPORT ANY D150REPANCIE5 TO ENGINEER PRIOR TO 5TARTINCG ANY WORK. THESE PLANS ARE THE PROPERTY OF VORTEX ENGINEERING, LLG., AND SHALL BE RETURNED UPON COMPLETION OF THE PROJECT. USE OR COPY IS PERMITTED BY CONTRACT ONLY, ANY CHANGE5 TO THESE PLANS, REGARDLE55 OF WOW MINOR, WITHOUT WRITTEN APPROVAL OF VORTEX ENGINEERING, LLG, OR ANY CONSTRUCTION EXECUTED FROM THESE PLANS WITHOUT THE EXPRE55 APPROVAL OF VORTEX ENGINEERING, LLG SHALL AUTOMATICALLY RENDER VORTEX ENGINEERING, LLG. HARMLE59 TO ANY LIABILITY, CLAIMS, SUITS, OR LITIGATION BY ANY INTERESTED PARTIES IN THE PROJECT. IF BOUND SPECIFICATIONS ACCOMPANY THESE PLANS, THEY SHOULD BE READ CAREFULLY FOR ADDITIONAL CONDITIONS. REVISIONS BY NEW CODE UPDATES DK/PK REVISIONS ADDED 142 MPH SHEETS DK/PK REVISIONS ADDED 160 MPH SHEETS DK/PK REVISIONS GEN NOTE REVISED DK/PK Q wz 2° Nc`n" I.IJ F-z0z wO wwu.F- FS=9aa mow— w n. 0ww u> gz'z_^ aczo $ j$Wzo z G x oc 3:fy ao��- �azaaW H �^ =zzz p�irz w 00 f <20W Z'jg0wc9 =z�w SF �=Zw V O Ci Q w aQ W J L. wo 4 Z uz W. U lr�zQF-uf V,J Q >U6D wl7W u�1j _.I w a Q O = w Z =agm �w N JM o M (� h Ln W M Z N M r4 a M ' a 00 J W uuj � RT 0 3: Ln _ N d u (' Z . uQ w Z ? cC60 o� LJJ 1 00 u Fi W a � N � tD0 z U) 0 0 L 0 DATE 03-0t5-18 SCALE NOTED DRAWN MK/PDK JOB Sheet content: Structural Details Sheet number: 54 NOTE: DECKING "AT 2x6 WALLS USE 5PH6 CONNECTORS IN LIEU OF 2"X4" PANEL BLOCKING @ 48" O/C r 5PH4 CONNECTORS SHOWN. FOR THE FIRST 8'-0'' OF ENID WALL ND FLOOR FRAMING At 2x8 WALLS USE 5PH8 FROM EA. END. (TYP) TOP d BOTTOM CONNECTORS IN LIEU OF 51MP50N SPH4 TO EA. DBL 2x 5.Y.P. TOP PLATE 5PH4 CONNECTORS SHOWN. STUD WITH 12-I06 x 1 1/2 CHORD ATTACHED W/ (2) 0.131" X 3 1/2" SIMPSON C516 OR M5TA36 STRAP COMMON TOE NAILS " FOR WALLS LARGER THAN NAILS, 6 32 32 � O.G,, EVERY OCHER 2x8, USE 51MP50N 5P1'5 ON STUD EACH 51DE OF STUD TO BOTTOM PLATE 4 SIMPSON FOLLOW TABLE BELOW 5P2'5 ON EACH SIDE OF FOR APPROPRIATE STUD TO TOP PLATES, U.N.O." SPACING 4 51ZE OF LOOK J015T-SEE FRAMING PLAN WALL STUDS. STUDS SHALL BE INSTALLED 6 WEEP SCREED IN5TAILED PER MAX. 16" O.C., SEE MANUR 'N'/5-3 51MP50N HETA20 s 32" O.G. MAX. 00 2x4 S.Y.P. RIBBON 2"X4" CR055 BRACE 00 EA. FLOOR o 45" O/C FOR THE TRUSS. TRU55. 15T 2'-0" OF END WALL C516 OR M5TA 36 6 W/ (4) 0.131X3 1/2" EA. END 32"O.C. (36" LONG) a INTO 2"X4" BLOCKING FROM EA. STUD TO (2X12) WOOD BLOCK OR FLOOR J015T DECKING 2x12 5YP "2 WOOD 3-0.131 x 3 1/2" 6 EA, BLOCK BETWEEN :: JOINT SIDE: 2"X4" PANEL BLOCKING FLOOR J015T WITH 5-16d HETA20 a 32" O.C. ON THE TOENAILS. ia 45" O/C FOR THE FIRST 2ND FLOOR FRAMING INSIDE FACE OF 2xl2 8'-0" OF END WALL FROM EA. END. (TYP) TOP SIMPSON C516 OR M5TA36 OR BOTTOM CHORD ATTACHED EQUAL AT EACH STUD, TO STUD NOTE: W/ (3) 0.131 X 3" TOE NAILS (ABOVE/BELOW), FLOOR JOIST, OR SEE 'N75-3 FOR STUD INFORMATION BLOCKING. LOOK J0I5T-5EE FRAMING PLAN SEGMENT LENGTH TO BE AS DELINEATED ON THE PLAN SET, OR ATTACH TRUSSES PER FRAMING NOTES. IF TRUSSES ARE PARALLEL, PROVIDE BLOCKING AT 24" O.G. AND ATTACH WITH (3) 0.131"x3-1/2" TOENAILS AT EACH END TYP. PROVIDE A MINIMUM 2 PLY END STUD AT EACH END OF SEGMENT FULL DEPTH BLOCKING 6 SHEATHING EDGES w/ (3) 0.131"x3-1/2" TOENAILS EA. END. CONSTRUCT WALL AS LOAD BEARING WITH UPLIFT REF. C/5-1. 6IMP50N HTT4 OR EQUAL AT EACH END OF SEGMENT INSTALL 5/8" THREADED ROD IN SIMPSON SET EPDXY OR EQUAL WITH 6" MIN EMBEDMENT, IF UNDELINEATED, SEGMENT LENGTH TO BE EQUAL TO OR GREATER THAN "H" SHEATHING AS DELINEATED ELSEWHERE IN PLAN DOUBLE TOP PLATE SET, (MIN. STUD GRADE 5YP) 2x STUDS s AL 1. t-rarne/lylasonry Connection #1 S-5 SCALE: NTS NOTE: ADD 2X4 BLOCKING 0 MSTA3( OR C51(o OR NOTE: 2"X4" CROSS BRACE HETA20 WHICH 15 NOT "AT 2x6 WALLS USE SPH6 Q 48" O/C FOR THE ALIGNED W/ TRU55 VERT. CONNECTORS IN LIEU OF 15T 2'-0" OF END WALL WEB U51NG 2-0.131'' X 3 1/2" 5PH4 CONNECTORS SHOWN. W/ (4) 0.131X3 1/2" 6 EA. ENE) TOENAILS a EA. END. AT 2x5 WALLS USE 5PH8 INTO 2"X4" BLOCKING CONNECTORS IN LIEU OF INSTALL SIMPSON c516 CRO55 STRAPS WITH (1) 5PH4 CONNECTORS SHOWN, FOR WALLS LARGER THAN 0.131"x3-1/2" NAIL AT EAc PASSING STUD AND 2x5, USE SIMPSON 5F'1'5 ON BLOCK, AND WITH 4 NAIL EACH SIDE OF 5TUD TO MINIMUM AT EACH END TOP AND BOTTOM TC BOTTOM PLATE 8 SIMPSON PLATE5/END STUDS. STRAPS SHOULD BE 5P2'5 ON EACH SIDE OF STUD TO TOP PLATES. U.N.O. FLOOR D DIAGONAL AND AT 45 SIMPSON 5PH4 TO 2"x4" PANEL BLOCKING a 48" O.G. FO J015T aw DEGREES OR LE55 IN EA. STUD TOP 8 THE FIRST 2'-0" OF END WALL FROM EA. (TYP) 0 RELATION TO BOTTOM OF WALL. END. (TYP) TOP 4 BOTTOM CHORD HORIZONTAL, TYPICAL. ATTACHED W/ (2) 16d TOE NAILS. 1/2 DIA NUT w/ MIN. 1- 1/4" *** WHEN CROSS BRACE ANGLE LU WASHER GREATER THAN 45° EXTEND PANEL 1/2" DIA ALL FOLLOW TABLE BLOCKING FOR THE FIRST 4'-0" OF END THREAD ROD BELOW FOR IF DOUBLE END 5TUD 15 OVER A /2" DIA APPROPRIATE SPACING 8 51ZE OF INSTALL 5ODD 2x 1/2" PIA --y. ANCHOR BOLT coupuNG SHALL BE STUDS. NSTALDLED JOINT BLOCKING BELOW: TYP A.B. EXTENSION DETAIL a „ N MAX. 1(o O.G. COUPLER NUT DIA. 1/2" J-BOLT5 2"x4" CROSS BRACE Q 45" O.C. FOR OR WITH 51MP50N SET EPDXY, 5° 2X4 RIBBON THE 1st 2'-0" OF END WALL W/ (2) 10dx3" EA. END INTO 2"x4" BLOCKING. AT CRO55 STRAPPED SEGMENT, IF SHEATHING 15 EMBEDMENT 6 24" w/ 3-16d S (ANGLE NOT TO EXCEED 45*) SEE *** WHEN GYPSUM WALLBOARD EA TRU55 DISTANCE 15 ATTACH WITH 6D COOLER *** WHEN ANGLE 15 GREATER THAN 45°, 7 GMU WALL SEE 2X BOTTOM PLATE WITH l4) NAILS AT 'I" O.OR "6 X CRO56 BRACE 6 40" D.G. FOR THE 15t LE55 THAN 2'-0" FLOOR TRUSSES FLOOR PLAN FOR NAILS AT EACH PA551NG ALONG SCREWS 6" O.G. 4'-0" OF END WALL. THE FIRST BAY LONG EDGES AND 12" O.G. TYP. MORE INFO. TRUSS OR NAILS ALONG THE IN THE FIELD. IF BOTTOM PLATE INTO A SHEATHING IS OTHER THAN PARALLEL TRU55/RIM J015T GYPSUM, SEE NAILING AT 4" O.G. ALL NAIL5 TO BE SCHEDULE AT 0/52. 0.131"x3-1/2" MIN. TYPICAL. SEEN'/5-3 FOR STUD INFORMATION 5IMP50N A35 ANGLE REFER TO TYPICAL 2-5TOR W/ 12-SdX 1 1/2" WALL SECTION FOR NAILS HORpUD TO INFORMATION NOT SHOWN C ALT. Frame/MasonryConnection #2 E Floor Truss Parallel To Br . Wall A Cross Stra in Detail 2X4 BEARING S-5 SCALE: NTS S-5 SCALE: NTS S-5 SCALE: NTS WALL. W/ STUDS a 16" O.G. 1/16 APA RATED WOOD SHEATHING SIMPSON 5PH4 EA. STUD NOTE: �� �. ..,..••A iV/ �,. NOTE: AT 2x6 IUALLS USE 5PH6 "AT 2x6 WALLS USE 5PH6 � �;•. `� G )NNECTOR5 IN LIEU OF ENGINEERED ROOF CONNECTORS IN LIEU OF ENGINEERED ROOF PRE-ENGINEERED PRE-ENGINEERED 5PH4 CONNECTORS SHOWN. TRUSSES 624" O.C. 5PH4 CONNECTORS SHOWN. TRUSSES �24" O.C. FLOOR JOIST ROOF TRUSSES AT 2x8 WALLS USE 5PH8 AT 2x8 WALLS USE 5PH8 C? CONNECTORS IN LIEU OF CONNECTORS IN LIEU OF r'- W p 5PH4 CONNECTORS SHOWN. 5PH4 CONNECTORS SHOWN. FOR WALLS LARGER THAN FOR WALLS LARGER THAN 1' INSULATION PER ENERGY CALC5 2x8, USE 51MP50N 5P1'5 ON INSULATION PER ENERGY CALLS EACH SIDE OF STUD TO 2x8, USE 51MP50N SPl'S ON �rr '%{y ••.,,,.•• ° ��-41% EACH 51DE OF STUD TO 1/2 GYPSUM CEILING BOARD BOTTOM PLATE SIl"1PSON 1/2 GYPSUM CEILING BOARD r,, * p � CEILING BOARD PER BOTTOM PLATE & SIMPSON ARCH. PLANS 5P2'6 ON EACH SIDE OF HURRICANE ANCHOR a EACH TRU55 5P2'5 ON EACH SIDE OF5TUD TO TOP PLATE5U" HURRICANE ANCHOR a EACH TRU55 STUD TO TOP PLATES. U.N.O. . .N.O. PROVIDE CONTINUOUS STRAPPING PROVIDE CONTINUOUS STRAPPING CONNECTION TO FOUNDATION CONNECTION TO FOUNDATION HT516 W/ 16-10d 2X4 BLOCKING w/ NOTE: DBL. 2X TOP PLATE DBL. 2X TOP PLATE EA. TRUSS To 3-0.131 x 3 v2° R.S. "At 2x6 WALLS USE SPH6 2x4 SOLE PLATE 5PH4 BOTTOM PLATE TOENAILS CONNECTORS IN LIEU OF 2x4 50LE PLATE 5PH4 -s EA. STUD EA. 57Up PER TRU55 PRE-ENGINEERED 5PH4 CONNECTOR5 SHOWN.. PROVIDE (2) 16d COM EACH TRUSS I/2" GYPSUM PROVIDE (2) 16d MANUFACTURER P R GIRDER AT 2x8 WALLS USE 5PH8 COM a EACH TRUSS 1/2" GYPSUM HANGER CONNECTORS IN LIEU OF 5PH4 CONNECTORS SHOWN. SIMPSON C516 W/ MIN (22) 10d 3/4'1 T4G GLUED W/ CONSTR. ADHESIVE SIMPSON C516 W/ MIN (22) 106 3/4" T4G GLUED W/ CON5TR. ADHESIVE FIOOr Truss TO Girder Connection FOR WALLS LARGER THAN COMMONS (12 MIN. EACH END) 4 NAILED SEE SCHEDULE DETAIL "0" COMMONS (12 MIN. EACH END) NAILED SEE SCHEDULE DETAIL "O" H 2x8, USE SIMPSON 5PI'5 ON S-5 SCALE: NTS EACH SIDE OF STUD TO 1705 MAX 24" O.C. MAX OR ON 5NEET 5-2 EAC MAX D 24 O.C. MAX OR ON SHEET 5-2 EACH STUD WRAP UNDER TOP EACH 5TUD WRAP UNDER TOP BOTTOM PLATE 4 SIMPSON PLATE (15T FLR) PRE ENGINEERED WOOD 5P2'S ON EACH 51pE OF PLATE (15T FLR) PRE ENGINEERED WOOD STUD TO TOP PLATES. FLOOR TRUSSES Q 24" O.C. FLOOR TRUSSES o 24 O.C. EXTEND SHEATHING TO U.N.O." 2x42 5YP RIM w/ (3) 2x4 02 5YP RIM w/ (3) 2nd FLOOR BOTTOM OF BEAM OR 16d NAILS EA. TRU55 I16d NAILS EA, TRU55 WALL GIRDER J015T (INSET) ,JOIST (INSET) I/2" GYPSUM BOARD 1,/2" GYPSUM BOARD 2X BEARING WALL W/ PROVIDE (3) 0.131 X EACH FLOOR Mt516 STUDS 16" O.C. 3-1/2" TOE NAILS AT EACH FLOOR TRU55 FLOOR TRU55 TO WALL 1/2" GYPSUM CEILING BOARD W/ KN CK 24" O.C. MAX. 7/16 APA RATED RE -ENGINEERED BELOW D GYPSUM FIN15H BOARD W/ KN GK - PRE -ENGINEERS /- WooD SHEATHING FLOOR TRUSS DOWN DRAG FIN15H SEE NOTE ON N-1 PAGE 'i/16" SHEATHING MIN.; DOWN DRAG FINISH SEE NOTE ON N-1 PAGE FLOOR TRU55 FOR GARAGE APPLICATION BEE GENERAL NOTE FOR GARAGE APPLICATION 2x6 SOLID BLOCKING W/ DBL. 2X TOP PLATE w/ 51MP50N 5PH4 FOR NAILING PATTERN DBL. 2X TOP PLATE w/ 51MP50N 5PH4 3-0,131 x 3 1/2" TOENAILS 6 16" O.C. w/ (12) 10d NAILS EACH 16 O.C. w/ (12) 10d NAIL5 EACH EA. END 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD 2 X 4 RIBBON ATTACHED TO EACH FLOOR JOIST WITH 3-0,131 I/2" ANCHOR BOLT 24" I/2" ANCHOR BOLT 24" x 3 1/2" NAIL5 - D.C. W/ NUT 4 2" SQUARE O.G. W/ NUT 2" SQUARE 51MP50N C516 ' i 516 EA. STUD PT 2X BOt. PLATE w/ BY 1/5" WASHERS FT 2X BOT. PLATE w/ BY I/8 WASHERS W/ MIN (22) 10d SIMP50N C 51MP5oN 5PH4 EA. BIMP5ON 5PH4 6 EA. MOMEACN END) TO BASE OF 2x4 51MP50N HT516 STUD w/ (10) lOd NAILS „ CUD w/ (10) 10d NAILS RIBBON BELOW EA. TRU55 4 CONC. SLAB. SEE EACH 4"GONG. SLAB. 5EE EACH FOUND. PLAN FOUND. PLAN BEAM /GIRDER TYP. LOAD SIMP50 VIE4O TO TYPICAL2-STORY WALL 4 BEARING WALLHETA20 Fo .CAL2- TION NOT W/UPLIFT FOOTING 5EE FOUNDATION FOOTING SEE FOUNDATION 2x BOT. PLATE PRE-ENGINEERED ON R PLAN FOR SIZES 4 MORE INFO. PLAN FOR SIZES MORE INFO. W/ ILS 61 x 3 1/2 FLOOR TRU55 CMU WALLNAIL5 6" O/C a Cantilevered Floor Truss Over Wall SCALE: NTS T ical Two Stor I nterlOr Bearin Wall Section Typical Two StoryInterior BearingShear Wall Section F Second Floor Frame Connection Girder S.5 � A-5 SCALE: NTS S-5 SCALE: NTS Al S-S SCALE: NTS NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD AND REPORT ANY D15CREPANCIE5 TO ENGINEER PRIOR TO 5TARTING ANY WORK. THESE PLANS ARE THE PROPERTY OF VORTEX ENGINEERING, LLC., AND SHALL BE RETURNED UPON COMPLETION OF THE PROJECT. USE OR COPY 15 PERMITTED BY CONTRACT ONLY. ANY CHANGE5 TO THESE PLANS, RE6ARDLE55 OF HOW MINOR, P41THOUT WRITTEN APPROVAL OF VORTEX ENGINEERING, LLC, OR ANY CONSTRUCTION EXECUTED FROM THESE PLAN5 WITHOUT THE EXPRESS APPROVAL OF VORTEX ENGINEERING, LLC SHALL AUTOMATICALLY RENDER VORTEX ENGINEERING, LLC. HARMLE55 TO ANY LIABILITY, CLAIMS, SUITS, OR LITIGATION BY ANY INTERESTED PARTIES IN THE PROJECT. IF BOUND 5PECIFICATION5 ACCOMPANY THESE PLANS, THEY SHOULD BE READ CAREFULLY FOR ADDITIONAL CONDITIONS. REVISIONS BY NEW CODE UPDATES DK/PK REVISIONS ADDED 142 MPH SHEETS DK/PK REVISIONS ADDED 160 MPH SHEETS DK/PK REVISIONS GEN NOTE REVISED DK/PK REVISIONS ADDED CROSS STRAPPING DET'L DK/PK 0 0 u, Z �, Uj �z0� �ZZw cc C W LL p � a s0. = m W a W W Ln° u 7 3p= W 3SzZH � owu'oaz �`- �0Uw0 CC w N qLL'� ". "K<aw W CMO as°� ZLo oz OC Z c.7 w Z�4f a� f-u. W �r ui 0 wvwo LL- §zwa•w0 Q W V=Lu ZZa�N UJ 0 LU W w � a,�., Q Q Lu I- Uj = CC Ujn K LLI tn � o a M J O M F- Ln ui h Z_ a M d M N Q 'd Ln � a� w -� 3uNi Z w O d N d t9 zLLr-Q W Z `x ni0 �w U w -Ji X Q moo a� Iw z Vi a O00 U, 0 I' Jl LU DATE SCALE Np7EU' DRAWN MK/PDK JOB - Sheet content: Structural Details Sheet number: DRYWALL OVER FUf BLOCK Il Il/16x11/16 COVE Mc (0100) Ix6 TRIM (WINDOW PER PLA (WINDOW — PER PLAN) COMPOSITE WINDOW BILL SQUARED DETAIL — EDGES lx6 TRIM BEAD BOARD -- PANELING DRYWALL FIN16H OVER FURRING ON BLOCK WALL (WINDOW PER PLAN) LINE OF WALL--,, BELOW SILL lx6 TRIM LINE OF TRIM BELOW COMPOSITE WINDOW DRYWALL FINISH SILL PLAN OVER FURRING ON BLOCK WALL WINDOW STOOL W/ TRIM AND BEAD BD. PLAN SPECIFIC PER PLAN TE WINDOW DETAIL 2 1/4' DOOR CASING ELEVATION (036(0) LINE OF WALL BELOW (NIGHE LINE OF CA51NG PER PLAN) BELOW z= COMP061TE WINDOW BILL PLAN DRYWALL FINISH OVER 2x WALL (SEE PLAN) NICHE STOOL DETAIL PLAN SPECIFIC PER PLAN WALE: I'm V-m' SHIM A5 1-4" TEMP. GL. ENCLOSURE SHIM AS 11_4" REQ,D. 8" W. CORIAN REQ'D. \\l GAP -- INVERTED 2 1/4' —r I" ...... RTED 2 1/ DOOR CASING l"366) a 1' DOOR CA51NG (0366) 2x 5TUD5 (PER 2x 5TUD5 (PER STD. 2x 5TUD5 (PER PLAN) 5T0. PLAN) :� 1 STD. PLAN) BA5E BASE 2" VAINTY GANNET 1/2' DRYWALL CABINET 1/2' DRYWALL GANNET O 3 114' BASE BD. 3 1/4' BASE BD. (036(0) (03(o6) QUARTER QUARTER 31/4' BASE BD, ROUND ROUND (036(0) CALI. TOP HIGH BAR TOP VANITY LOW WALL 5CALE: 1/2' : 1' 0' 5CALE: 112' -- I'-0' 5CALE: 1/2' = 14" TILE TO 8" W. CORIAN TEMP. GL. ENCLOSURE WRAP IN CAP WINDOW I/2' DRYWALL 8' W. CORIAN BELOW CAP CAP TILE FIN15H r� TILE FIN15H OVER 2x 5TUD5 (PER I I OVER WATER RESISTANTER PLAN) �I II RESISTANT WALL BD. II II WALL BD. 1/2'DRYWALL it li SHOWER BATH I I SHOWER BHOWER I� 3 1/4" BASE BD. iI SfDE% II (�366) II 1 I SECTION PLAN SHOWER LOW WALL SCALE: 1/2': 1'-0' /ERIFY TOP LE (WINDOW PER PLAN) COMP051TE WINDOW - BILL SQUARED DETAIL — EDGES INVERTED 2 1/4' DOOR CA51NG (#36(6) DRYWALL FINISH OVER FURRING ON BLOCK WALL (WINDOW PER PLA LINE OF l BELOW AN BILL )JECT 1/2" OUT ECEIVE TILE) LINE OF t BELOW COMP061 BILL SHOWER WINDOW SCALE: 1/4'-- 1'-0' SILL ELEVATION .WALL FINISH PLAN OVER FURRING ON BLOCK WALL TYP. WINDOW STOOL DETAIL 5CALE: r = r•m' rE WINDOW DETAIL 2 1/4' ' ING FLOORING / 5,45E BOARD NOTE: WPEN TILE FLOOR 15 5ELECTED ONLY 5,45E 50ARD 15 IN5TALLED. WPEN WOOD FLOOR 15 5ELECTEO 5,45E 5O4RD AN[) 5HOE 1IOULD ARE IN5TALLED. Ix JAMB (BI-PA6� DRS. PEF PLAN) DRYWALL FINISH OVER 2x WALL (SEE PLAN) 2 1/4" DOOR CA51NG (�3(o6) MELD DOWN 1/2" 1/2' WOOD FILLER HEAD DRYWALL FIN15H OVER 2x WALL (SEE (5I-PA55 PLAN) DRS. PER PLAN) I/2"�I 2 1/4' DOOR CASING (036(o) HELD OVER 1/2' PLAN TYP. BI-PASS DRS. CASING DETAIL 5CALE: r = r-V MAIN HOUSE GARAGE DRYWALL BASE BD, TO OVER _ LAP SLAB STEP AND DRYWALL TRANSITION 3 1/4' BASE BD. TYP. BASE BD. AT GARAGE / MAIN HOUSE 5CALE: I'-- 1'-0' 5 I/4" CROWN S(45) 5 1/4" CROWN Ix8 ROUNDOVER W/ ROUTER WHITE PINE 1/2' DRYWALL 31/4' RASE BD. (%b) 2xb WALL 36' OR 42' HIGH PER PLAN 2x4 STAIR KNEE WALL CAP DETAIL PLAN SPECIFIC PER PLAN KALE r . r m' IxlO ROUNDOVER W/ WHITE PINE ROUTER I!2' DRYWALL `-31/4' BASE BD. 24 WALL 36' OR 42' HIGH PER PLAN 2x6 STAIR KNEE WALL CAP DETAIL PLAN SPECIFIC PER PLAN scaLE: r = "0' •_.' N W o N� �MM U. • 0 0 NM Ir M a 'JQB NUMBER 22066' CAD RE ISSUED 06-16-16 nn�c=rn nos n� e� DAVIS BEWS DESIGN GROVP 150 STATE STREET EAST OLDWAR, FLORIDA 34677 813.925.1300 TEL 813.925.1800 FAX WWW.DAVISBEWSCOM TAMPA • L?FX.1VM EST.19% TRIM 7771E TYPICAL TRIM DETAILS • SHEET • NOTE., DR,4WIN & ON 11 "xll 5�IEET WILL 5E ONE HAL P THE 5CALE NOTED TRIM DETAILS LJ-1021 STANDARD - 42" H. R05ETTE 45;� 1 (OFT.�LJ-6010 L RAILING SHOWN) E WEL L P05T NEP Ix6 PAINTED BASE PLATE 3 1/4" BASE BD. LJ-1011 LEVEL QUARTER TURN A5 APRON LJ-1011 LEVEL LJ-4042 QUARTER TURN LJ-4045 LJ-4040 NEWEL POST NEW L P05t NEWEL �� POST OPT. LI14-MG2KNUC44 WROUGHT IRON BALUSTERS LJ-1021 will ^ Ix6 PAINTED BASE R05ETTE _ PLATE LJ-6010 lxl2 SKIRT 3 1/4" BASE RAILING BOARD AS APRON LJ-5015 WOOD BASE BALUSTERS CAR (3 PER TREAD) MOULD STANDARD - LJ-5014MR1 _ TREAD FOR CARPET Ix12 5KIRT (OPT. LJ-8010 SERIES BOARD TREAD SHOWN) LJ-W'95 OAK — ix8 PAINTED LINEAL COVE — R15ER MOULDING LJ-8010MR1 BASE .-�_----� OAK TREAD PER TM LEVEL 3 1/4" OR 5 1/4" LJ-4042 NEWEL POST 2 EA. - LJ-3018 RAIL AND P05T FASTENER GENERIC SWITCHBAry STAIR DETAIL N.T.S. GENERAL STAIR NOTE: REFER TO FLOOR PLANS FOR TREAD DEPTH AND RISER HEIGHT REQUIRED. 71C INDICATES STRIP FLOORING: TO BE INSTALLED IN SAME ORIENTATION AS 5 1/4" LANDING: TREAD LJ-8090-5 OAK 5 1/4" LANDING TREAD RAILING SEE GENERAL STAIR NOTES RAILING LJ-4042 NEWEL POST GENERIC WOOD SWITCHBACK STAIR FLOOR PLAN N.T.S. STANDARD - 42" H. KNEEWALL (OPT. LJ-(o010 RAILING SHOWN) OPT. LI14-MG2KNUC44 WROUGHT IRON BALUSTERS .Q LJ-4040 NEW PO5T�/� LJ-4040 NEWEL POST SECTION--- CUT THRU I �\ 1x12 SKIRT Ix6 PAINTED BASE PLATE � BOARD WALL `:`�<. j 3 I/4" BASE LJ-6010 AS APRON ` RAILING LJ-1041/8 BASE 5-TURN MAP p STANDARD - LJ-8014MR1 LJ-5015 WOOD _ TREAD FOR CARPET BALUSTERS (OPT. LJ-8010 SERIES (3 PER TREAD) TREAD) LJ-8095 OAK lx8 PAINTED LINEAL COVE RISER MOULDING Ld-8010MRI BASE PER TM LEVEL OAK TREAD 3 I/4" OR 5 1/4" Ix12 SKIRT��/ �LJ-4042 BOARD NEWEL POST ���2 EA. - LJ-3018 RAIL AND P05T FASTENER GENERIC STRAIGHT RUN STAIR DETAIL N.T.S. STAIR AND RAILING RULES I. WHEN PLAN INDICATES 5ULLN05E STARTER STEP - INSTALL WITH PIN NEWEL AND TURNOUT FITTING. 2. WHEN PLAN INDICATES STANDARD OAK TREAD - INSTALL NEWEL ON FLOOR AND ATTACH INTO FIRST RISER, 3. ALL PLANS THAT INDICATE BALUSTER RAILINGS WITH OPEN TREADS - MINIMUM SPEC 15 FIRST TREAD TO BE FULL OAK WITH CLEAR COAT. CARPET RUNNER STARTS AT NEXT RISER. 4. WHEN "OPEN BALUSTER RAILING" 15 ON BOTH SIDES OF STAIR, THE TREADS ARE OAK WITH PAINTED RISERS. CARPET RUNNER STARTS WHEN ONE OR BOTH WALLS BEGIN. WHEN ONE SIDE REMAINS "OPEN RAILING", INSTALL HYBRID TREADS WITH CARPET RUNNER. 5. HANDRAILS - WALL MOUNT OR BALUSTER - RUN ALONG "OUTSIDE" OR "LONG SIDE" UP STAIRWELL. "CONTINUOUS" RAIL INSTALLED PER CODE AS NECESSARY. M05T JURISDICTIONS DO NOT REQUIRE HANDRAILS AT LANDINGS. 6. BALUSTERS (WOOD OR METAL) AT STEPS- FIN15H AND APPEARANCE - WHEN INSTALLATION 15 COMPLETE, DESIGN COMPONENTS (BASKETS, KNUCKLES, SCROLLS, AND TURNINGS) SHOULD FOLLOW SLOPE OF THE TOP RAIL, 1. ON UPPER FLOOR BALUSTER RAILINGS, MAXIMUM 12" SPACE BETWEEN NEWEL5. 6. FINISHES - ALL OAK HAS CLEAR -COAT FINISH AS STANDARD. ALL OAK COVE MOLDINGS (UNDER TREADS) TO BE CLEAR -COAT AS WELL. OPTION UPGRADE5 FOR STAIN COLORS. 5. ALL WOOD RISERS TO BE PAINTED WHITE. LJ TR LJ TR FULL HT. WALL CARPET STARTS AT THIS R16ER RAILING LJ-4042 NEWEL POST GENERIC WOOD /CARPET STAIR FLOOR PLAN kTS. Ix12 SKIRT SECTION CUT (WALL `<� j LJ-6010 RAILING ` BASE LJ-1041/8 --- ``JJ CAP S-TURN MOULD STANDARD - LJ-6014MRI LJ-5015 WOOD TREAD FOR CARPET BALUSTERS r (OPT. LJ-8010 SERIES (3 PER TREAD) TREAD) LJ -8095 OAK �-- a LINEAL COVE MOULDING 15A5E---`' - Ix8 PAINTED PER TM LEVEL RISER 3 1/4" OR 5 1/4" IX12 SKIRT LJ-1040 / 1045 BOARD TURNOUT LJ-3009 LJ-4010 NEWEL POST BRACKET LJ-8010 STARTING STEP GENERIC TURNOUT W/ WOOD AND CARPET STRAIGHT RUN STAIR DETAIL LJ-5015 WOOD BALUSTERS (3 PER TREAD) LJ-6010MRI OAKTREAD5 LJ-6095 OAK LINEAL COVE MOULDING Ix12 SKIRT BD, BASE CAP MOULD TYP. OPEN TREADS W/ PICKETS AT STAIRS DETAIL Na TO 8cxE LJ-404 42" H. LJ-1021 NEWEL RAILING ROSETTE P05T LJ-6010 36" H. RAILING RAILING LJ-5015 WOOD 3 1/4" BASE BALUSTERS AS APRON (3 PER TREAD) LJ-4042 WOOD TREAD NEWEL POST Ix12 SKIRT BD. BASE LJ-80S OAK pC CAP LINEAL COVE MOULD MOULDING PER PLAN DER TM LEVEL 3 1/4" OR 5 1/4" TYP. OPEN TREADS W/ WOOD BALUSTERS AT STAIRS N.T.5. N.T.S. N N i LJ-4010 LJ-4045 LJ-4042 LJ-4040 TYPICAL NEWEL POST PROFILES N.T.S. LJ-5015 LI14-HOLI5,45K44 LIH-HOL25A5K44 LIH-HOLIKNUC44 LIH-HOL2KNUG44 LIH-HOLPLA44 LIH-HOL50144 (PLAIN) W/ LI-ALAK01 (2 EA. ADJ. KNUCKLE) TYPICAL BALUSTER PROFILES KT.5. 3/4" MIN, HOLE DEPTH--C FOR BALUSTERS IN TO HAND RAIL (KEEP HOLE DEPTH THE SAME AT EACH BALUSTER) 36" H. RAILING' �``� LJ-6010 RAILING LJ-4042 NEWEL P05T LINE OF BALUSTERS TO BE PARALLEL TO TOP RAIL `— LJ-5015 42" WOOD BALUSTERS (3 PER TREAD AND EQ. SPACED) TYP. WOOD BALUSTER INSTALLATION DETAIL N.T.S. I" MIN. HOLE DEPTH FOR BALUSTERS IN TO HAND RAIL (KEEP HOLE DEPTH THE SAME AT EACH BALUSTER) 36" H RAILING LJ4010 RAILING LJ-4042 NEWEL P06T LINE OF BA5KET5 TO BE PARALLEL TO TOP RAIL LIH-HOL25A5K44 (DOUBLE BASKET) LIH-HOLIBA51<44 (SINGLE BASKET) DECORATIVE METAL BALUSTERS (3 PER TREAD - ALTERNATE BASKETS AND EQ. SPACED) TYP. LEVEL 2 DECORATIVE METAL BALUSTER INSTALLATION DETAIL NOTE: DIRAWING& ON 11 "x17 6�4EET UJILL 5E ONE �4ALF THE &CALF NOTED N.T.S. 1 I" MIN. HOLE DEPTH FOR BALUSTERS IN TO HAND RAIL (KEEP HOLE DEPTH THE SAME AT EACH BALUSTER) 36" H. RAILING — LJ-6010 RAILING LJ-4042 --` NEWEL P05T LINE OF -- • KNUCKLES TO BE PARALLEL TO TOP RAIL LIH-HOL2KNUC44 (DOUBLE KNUCKLE LIH-HOLIKNUC44 (SINGLE KNUCKLE) DECORATIVE METAL BALUSTERS (3 PER TREAD - ALTERNATE KNUCKLES AND EQ. SPACED) TYP. LEVEL 1 DECORATIVE METAL BALUSTER INSTALLATION DETAIL N.T.S. I" MIN. HOLE DEPTH FOR BALUSTERS IN t0 HAND RAIL (KEEP HOLE DEPTH THE SAME AT EACH BALUSTER) 36" H. RAILING LJ-6010 RAILING LJ-4042 NEWEL POST LINE OF SCROLL TO BE ,. PARALLEL TO TOP RAIL LIH-HOL50144 LIH-WOLPLA44 (SCROLL) (PLAIN) rm LI-ALAK01 (2 EA. L4ADJ. KNUCKLE) DECORATIVE METAL BALUSTERS (3 PER TREAD - 1 - SCROLL All- 2 - KNUCKLES AND EQ. SPACED) TYP. LEVEL 3 DECORATIVE METAL BALUSTER INSTALLATION DETAIL N.T.S. STAIR DETAILS x 4 w C 0 Nm C4 W 2GM� M 6 �• 0 � a • coC1 - E �dh Q DAVIS BEWS DESIGN GROVP 150 STATE SMEEr EAST WYMAR, MORMA 34677 813.925.1300 TM 813. 925. 1800 FAX W W W.DAVISREWS.COM TAMriA • IDEV, E EST. 1994 szz - STAIR L J • T1TLE • TYPICAL STAIR DETAILS • SHEET •