HomeMy WebLinkAbout1121-1197 W Airport Blvd (fire review) (a)SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: September 16, 2005 Business Address: 1105-1117 W.Airport Blvd. Occ. Ch. 40 Industrial -38 -Business Business Name: BRIO CENTER Architect: JRJJ & Associates Contractor: Design Enterprise . PH (407) 830-1414 Fax. (407) 830-8448 P H (407) 875-0115 Fax. (407) 875-0308 PH (407) 830-1414 Fax. (407) 830-8448 reo waet?oCt<>?wed' hxi 1] Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Comment: Plans reviewed as Occ. Ch. 40 Industrial -38 -Business Type IVfire sprinkler protected 20,160 sq ft type iv fire sprinkled building Occupancy's FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections. Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. F Fire Alarm requirement: The fire sprinkler system shall be monitoredfor the following: water flow fire sprinkler system. Tamper valves will be required on all interior and exterior ofall fore sprinkler valves Fire Alarm notification: Each individual tenant space shall have two (2) horn strobes, for individual tenant notification (one in business office, and one in storage/industrial area). 1 a'- SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407302-2520 / FAX (407) 302-2526 Application — New Building (20,160 s. q. ft.) 1.1 Mixed — N/A, Special Definitions — Ch. 40 Industrial -38 -Business Classification of Occupancy — Ch. 40 Industrial -38 -Business Classification of Hazard of Contents — Ordinary in office areas, and storage area classified as "High Hazard" per L.S.C. 101 1.2 Minimum Construction — Shall comply with Florida Building Code 2004 mercantile occupancy 1. 3 22 Means of Egress Components . ets;LWT':; ellaw art: .: r::ladan : tc:` :dace 2.3 Capacity of Egress— sales floor area based on one (])_person per 30 sqft., storage area based on one (])person per 300 sq. ft. 2.4 Number of Exits — two for each individual tenant ok 2.5 Arrangement of Egress O.K. — two for each individual tenant ok 2.6 Travel Distance — R. S B 1I 2 I2'I 44 ... ila u .. int Qn leadzr tri .clow.::::.iii.. 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress —additional EXIT SIGNS may be required (power shut down test required at night only) 2.9 Emergency Lighting — (1) foot candle (10 lx & a minimum at any point of 0.1 foot-candle (I LX ) measured along the path of egress at floor level. Therfore additional emergency lights may be required, (power shut down test required at night only) EmergencyLLights required In all rest rooms & Main Electrical Room *). 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features —Reserved 3.1 Protection of Vertical Openings — Ch. 40 Industrial -38 -Business shall have an automatic -fire sprinkler system, design criteria FA r SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407302-2520 / FAX (407) 302-2526 shows rack storage maximum height in sto ae area(rP 3.2 Protection from Hazards – (See exception 40-3.2.1 .LSC 101) 3.3 Interior Finish – Not required, building has an automatic fire sprinkler system 3.4 Detection, Alarm and Communications System: (as per N.F.PA.72- 3-8.3.1.2 (99) Ed. 3.5 Extinguishing Requirements – as per NFPA 10, (10) ten 4A60 rated fire extinguishers required per N.F.PA. #10 (see blueprints for locations). 5.1 Utilities – as per LSC 7-1 5.2 HVAC – as per LSC 7-2 5.3 Elevators, Escalators, Conveyors (4A-47) – N/A Sanford City Code – Chapter9: Required; Fire Sprinklers. Fire Department will field all inspectors test. Monitoring: Required on allfire sprinkler valves (includes inside and out) Other: NFPA 1 3-5.1 Fire Lanes – Required (see sight plan) 3-6.1 Key Box —One (1) required already application attached) 3-7.1 Bldg. Address Number Posted and Legible –Post address in 6 " six inch numbers contrasting in color (see blueprints). 3