HomeMy WebLinkAbout01_PHASE 1 COMBINED 2017-12-19 CONFORMEDJACKSONVILLELAKE CITYGAINESVILLEPERRYCITYTALLAHASSEEAPALACHICOLAOCALALEESBURGORLANDOLOCATIONDAYTONA BEACHST. AUGUSTINEKISSIMMEEPENSACOLAPANAMAMARIANNAOF PROJECTLAKEFT. PIERCEMELBOURNEBRADENTONLAKELANDTAMPAHAINES CITYOKEECHOBEEOKEECHOBEEMIAMIWEST PALMFT. MYERSKEY WEST BEACHSANFORDLOCATION MAPRD.MYRTLEST.PINE WAYLake JessupBEARDALLAVE.ORLANDOSANFORDINTERNATIONALSANFORDGENEVA AVE.SEABOARDCLUBRD.COUNTRYLONGWOOD-LK.MARYRD.BOULEVARDWOOD BLVD.GREENCROSSINGSMARYLAKELAKE EMMA ROADCELLERYAVE.St.JohnsRiverLake MonroeBOULEVARDORANGELAKE FORESTUPSALARD.LAKEMARYRHINE-HARTPRIMERATIMACUANPAOLA RD.COASTAIRPORT.BLVD.LINERAILROADSANFORDAVENUE42741917924271-41515469217415A46AIRPORT417417N.T.S.LLENDESTSheet No.G100ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDAPROJECT ALPHA ONE (TERMINAL EXPANSION) PREPARED FOR:SANFORD AIRPORT AUTHORITYAirport Authority Board of DirectorsFrank S. Ioppolo, Jr., Esq, ChairmanTim M. Slattery,Vice ChairmanJennifer T. Dane, Esq., Secretary/TreasurerU. Henry Bowlin, Board DirectorTom Green, Board DirectorWilliam R. Miller, Board DirectorClyde H. Robertson, Jr., Board Director Clayton D. Simmons, Esq., Board DirectorStephen P. Smith, Board DirectorA.K. Shoemaker, Chairman EmeritusKenneth W. Wright, Counsel Airport Authority StaffDiane H. Crews, A.A.E., President and CEOGeorge D. Speake, C.M., Executive Vice President & COO Airport Security CoordinatorDon Poore, PMP, Chief Financial OfficerJennifer Taylor, Project CoordinatorCONFORMED DOCUMENTS - PHASE 1DESIGNERS OF RECORD:CIVIL:Jeremiah Owens, P.E.Hilary Maull, P.E.Architect:John Baer, AIAStructural:Jose Ortiz, P.E.Mechanical:Plumbing:Electrical:Fire Protection:David Melfi, P.E.Survey:Randy Roberts, PLSBaggage Systems :John MajewskiLandscape:Maxwell D. Spann, PLATimothy Nash, P.E.CONFORMED SET1
500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 9:04:24 AMG101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAPROJECT INFORMATION07-14-2017S12014ORLANDO SANFORD INTERNATIONAL AIRPORT BUILDING INFORMATION:ADDRESS:STREET ADDRESS:1200 RED CLEVELAND BLVDCITY:SANFORDCOUNTY:SEMINOLE COUNTYSTATE:FLORIDAZIP CODE:32773BUILDING CODES:GOVERNING JURISDICTION:CITY OF SANFORDNOA'S: ALL NOA'S SHALL MEET REFERENCED BUILDING CODESBUILDING DATA:TERMINAL A - NEWA-3DESIGN LOADS:ULTIMATE DESIGN WIND SPEED:144 MPHIMPORTANCE FACTOR:I = 1.0EXPOSURE:EXPOSURE CINTERNAL PRESSURE COEFFICIENT:+/- 0.18BUILDING RISK CATEGORY:IIILIFE SAFETY SYSTEM:EMERGENCY LIGHTING:X YES NOEXIT SIGNS:X YES NOFIRE ALARM AND SMOKE DETECTION SYSTEMX YES NOPANIC HARDWARE:X YES NOFIRE SPRINKLERS: YES NODATEJOHN A. BAER, AIATO THE BEST OF THE ARCHITECT'S KNOWLEDGE INFORMATION, AND BELIEF, THIS DESIGN IS IN COMPLIANCE WITH APPLICABLE CODES AND LAWS.CERTIFICATIONREVISION / ADDENDUM NO.DATEREVISIONREVISION / ADDENDUM HISTORYX100% BID DOCUMENTSPROJECT ALPHA ONE - PHASE 11200 RED CLEVELAND BLVD SANFORD, FL 32773JULY 14, 2017TERMINAL A - EXISTINGOCCUPANCYUSE GROUPA-3SQUARE FOOTAGES20,000 S.F.57,400 S.F.OFFICE SPACE - EXISTING - FOR FIRE PROTECTIONB30,000 S.F.TERMINAL B -SCREENING ADDITION8,000 S.F.BTERMINAL B - EXISTINGA-3A-3TERMINAL B - NEW -INCLUDING CANOPIES 17,000 S.F.20,000 S.F.LOADING DOCK / BADGING / POLICE STATIONB4,400 S.F.CONSTRUCTION TYPE2B2B2B2B2B2B2BBUILDING CODE EDITION: FLORIDA BUILDING CODE2014MECHANICAL CODE EDITION: FLORIDA MECHANICAL CODE 2014 ELECTRICAL CODE EDITION: NATIONAL ELECTRICAL CODE 2011, NFPA 70PLUMBING CODE EDITION: FLORIDA PLUMBING CODE 2014ADDITIONAL CODE EDITION: FLORIDA FIRE PREVENTION CODE 2012 FLORIDA ACCESSIBILITY CODE2014MAIN AIRPORT BUILDINGSTAND ALONE BUILDINGREVISIONS# DATEDESCRIPTIONBY2 08-11-2017 ADDENDUM 2BASIC DESIGN WIND SPEED:112 MPHCONFORMED DOCUMENTSSEPTEMBER 29, 2017CONFORMED SET2
GENERALCOVER SHEETG100PROJECT INFORMATIONG101INDEX OF DRAWINGS - GENERALG102AINDEX OF DRAWINGS - PHASE 1G102.2INDEX OF DRAWINGS - PHASE 1G102.3GENERAL INFORMATIONG105GENERAL NOTES & PROJECT FINISHESG106AIRPORT SAFETY AND SECURITY NOTESG107EXISTING SYSTEMS CENTERSG108AREA OF WORK / PHASING PLAN - 1ST FLOORG109AREA OF WORK / PHASING PLAN - 2ND FLOORG110ADA SPECIFICATIONSG11108-11-17INDEX OF DRAWINGS - PHASE 1G102.1SHEET INDEX LEGENDCOMPOSITE PLAN - LIFE SAFETY - FIRST FLOORG112COMPOSITE PLAN - LIFE SAFETY - SECOND FLOORG113WALL TYPESG114WALL TYPESG115FINISH DETAILSG116B BAGGAGEBC3 BAGGAGE CLAIM 3BH BLOCK HOUSE ADDITIONC CIVILECY EAST CHILLER YARDELD EXISTING LOADING DOCKFIS CUSTOMS AND INTERNATIONALFP FIRE PROTECTIONG GENERALGD GENERAL DEMOLITIONGE GENERAL ELEVATORH HARDSCAPEI IRRIGATIONIB INBOUNDM MECHANICALL LANDSCAPELD NEW LOADING DOCKNEE NEW EXTERIOR ELEVATORNIE NEW INTERIOR ELEVATORP PLUMBINGOB OUTBOUNDS STRUCTURALSA SCREENING AREA EXPANSIONSPL SOUTH PARKING LOTSW SKYWALKW WAYFINDINGWEC WEST CHILLER YARD08-25-1709-06-1709-26-17INDEX OF DRAWINGS - PHASE 1G102.4XXXXX09-28-17500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:47:33 AMG102APROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINDEX OF DRAWINGS - GENERAL07-14-2017S12014REVISIONS# DATEDESCRIPTIONBYCONFORMED SET3
08-11-17WALL SECTION AND DETAILS - SCREENING AREA1-SA-A303ENLARGED FLOOR PLAN - SCREENING AREA1-SA-A401ENLARGED RESTROOM PLAN - SCREENING AREA1-SA-A402DETAILS - SCREENING AREA1-SA-A5011-SA-A6011-SA-A602ENLARGED PLAN AND INTERIOR ELEVATIONS -SECURITY EXIT - SCREENING AREA1-SA-A403DOOR SCHEDULE KEY PLAN - SCREENING AREADOOR SCHEDULE, DOOR ELEVATIONS AND DETAILS -SCREENING AREADEMOLITION PLAN - SCREENING AREA AND SAAOFFICES1-SA-A100DEMOLITION REFLECTED CEILING PLAN - SCREENINGAREA1-SA-A102LIFE SAFETY PLAN - SCREENING AREA1-SA-A103FLOOR PLAN - SCREENING AREA1-SA-A104REFLECTED CEILING PLAN - SCREENING AREA1-SA-A105ROOF PLAN - SCREENING AREA1-SA-A106EXTERIOR ELEVATION - SCREENING AREA1-SA-A201BUILDING SECTIONS - SCREENING AREA1-SA-A301WALL SECTIONS AND DETAILS - SCREENING AREA1-SA-A302WALL SECTION - NEW EXTERIOR ELEVATOR1-NEE-A302DEMOLITION PLAN - NEW INTERIOR ELEVATOR1-NIE-A100FLOOR PLANS - NEW INTERIOR ELEVATOR1-NIE-A101WALL SECTIONS - NEW INTERIOR ELEVATOR1-NIE-A301INTERIOR ELEVATIONS - NEW INTERIOR ELEVATOR1-NIE-A702AIRPORT NOTES ACCESS ROUTEAND STAGING NOTESG1.02SAFETY DURING CONSTRUCTION PLAN ACCESSROUTE & STAGING PLANE PHASE IG1.03G1.05PROJECT OVERVIEW - ALL PHASESG1.06OVERVIEW - PHASE 1CD1.00DEMOLITION PLAN - PHASE 1CD1.01DEMOLITION PLAN - PHASE 1CD1.02DEMOLITION PLAN - PHASE 1CD1.03DEMOLITION PLAN - PHASE 1C1.00SITE DIMENSION PLAN PHASE 1C1.01SITE DIMENSION PLAN PHASE 1C1.02SITE DIMENSION PLAN PHASE 1C1.03SITE GRADING PLAN PHASE 1C1.04SITE GRADING PLAN PHASE 1C1.05SITE GRADING PLAN PHASE 1C1.05SITE GRADING PLAN PHASE 1C1.06SITE UTILITY PLAN PHASE 1C1.07SITE UTILITY PLAN PHASE 1C1.14STORMWATER POLLUTION PREVENTION PLANPHASE 1LANDSCAPINGSHEET LAYOUT PHASE 1L0.01LANDSCAPE PLAN PHASE 1L1.00LANDSCAPE PLAN PHASE 1L1.01LANDSCAPE PLAN PHASE 1L1.02LANDSCAPE PLAN PHASE 1L1.03LANDSCAPE PLAN PHASE 1L1.04LANDSCAPE PLAN PHASE 1L1.05LANDSCAPE PLAN PHASE 1L1.07LANDSCAPE PLAN PHASE 1L1.08HARDSCAPE PLAN PHASE 1H1.00HARDSCAPE DETAILS PHASE 1H1.01OVERALL IRRIGATION PLAN PHASE 1I0.01IRRIGATION PLAN PHASE 1I1.00IRRIGATION PLAN PHASE 1I1.01IRRIGATION PLAN PHASE 1I1.02IRRIGATION PLAN PHASE 1I1.03IRRIGATION PLAN PHASE 1I1.04IRRIGATION PLAN PHASE 1I1.05IRRIGATION PLAN PHASE 1I1.06IRRIGATION PLAN PHASE 1I1.07IRRIGATION PLAN PHASE 1I1.08COMPOSITE DEMOLITION PLAN - 1ST FLOOR PHASE 11-GD-A101COMPOSITE DEMOLITION PLAN - 2ND FLOOR PHASE 11-GD-A102LIFE SAFETY PLAN - NEW LOADING DOCK1-LD-A100FLOOR PLAN - NEW LOADING DOCK1-LD-A101REFLECTED CEILING PLAN - NEW LOADING DOCK1-LD-A102ROOF PLAN - NEW LOADING DOCK1-LD-A103EXTERIOR ELEVATIONS - NEW LOADING DOCK1-LD-A201EXTERIOR ELEVATIONS - NEW LOADING DOCK1-LD-A202BUILDING SECTIONS - NEW LOADING DOCK1-LD-A301WALL SECTIONS - NEW LOADING DOCK1-LD-A302WALL SECTIONS - NEW LOADING DOCK1-LD-A303ENLARGED PLANS RESTROOM - NEW LOADING DOCK1-LD-A401DETAILS - NEW LOADING DOCK1-LD-A501DOOR SCHEDULE AND KEY PLAN - NEW LOADINGDOCK1-LD-A601DOOR DETAILS, ELEVATIONS AND HARDWARE SETS -NEW LOADING DOCK1-LD-A602WINDOW SCHEDULE AND KEY PLAN - NEW LOADINGDOCK1-LD-A603FINISH PLAN AND SCHEDULE - NEW LOADING DOCK1-LD-A701INTERIOR ELEVATIONS - NEW LOADING DOCK1-LD-A711INTERIOR ELEVATIONS - RESTROOMS - NEW LOADINGDOCK1-LD-A712FINISH DETAILS - MILLWORK - NEW LOADING DOCK1-LD-A721DEMOLITION PLAN - EXISTING LOADING DOCK1-ELD-A100FLOOR PLAN - EXISTING LOADING DOCK1-ELD-A101REFLECTED CEILING PLAN - EXISTING LOADING DOCK1-ELD-A102EXTERIOR ELEVATION - EXISTING LOADING DOCK1-ELD-A201DETAILS - EXISTING LOADING DOCK1-ELD-A501DOOR SCHEDULE AND KEY PLAN - EXISTING LOADING DOCK1-ELD-A601FINISH PLAN AND SCHEDULE - EXISTING LOADINGDOCK AND NEW LOADING DOCK ELEVATOR1-ELD-A701ENLARGED FLOOR PLAN, DOOR SCHEDULE ANDDOOR DETAILS - NEW EXTERIOR ELEVATOR1-NEE-A101REFLECTED CEILING PLAN, ROOF PLAN AND DETAILS -NEW EXTERIOR ELEVATOR1-NEE-A102EXTERIOR ELEVATIONS - NEW EXTERIOR ELEVATOR1-NEE-A201WALL SECTION - NEW EXTERIOR ELEVATOR1-NEE-A301PHASE 1 DRAWINGSCIVILGENERAL NOTESG1.01G1.04SHEET LAYOUT PLAN PHASE 1C1.08SIGNAGE AND STRIPING PLAN PHASE 1C1.09SIGNAGE AND STRIPING PLAN PHASE 1C1.10SIGNAGE AND STRIPING PLAN PHASE 1C1.11TURN LANE DESIGN PLAN AT INTERSECTION OF E.AIRPORT BLVD AND RED CLEVELAND BLVDC1.12REFERENCE ONLY FIRE LINE PLANBOLLARD LAYOUT PLANC1.13C1.15STORMWATER POLLUTION PREVENTION PLANPHASE 1C1.16STORMWATER POLLUTION PREVENTION PLANPHASE 1C1.17STORMWATER POLLUTION PREVENTION DETAILSPHASE 1GENERAL DETAILSC1.18GENERAL DETAILSC1.19LANDSCAPE DETAILS PHASE 1L1.09LANDSCAPE PLANT LIST PHASE 1L1.10IRRIGATION LEGEND PHASE 1I1.09IRRIGATION DETAILS PHASE 1I1.10IRRIGATION DETAILS PHASE 1I1.11IRRIGATION DETAILS PHASE 1I1.12ARCHITECTURE1-G-A101COMPOSITE FLOOR PLAN - 1ST FLOOR PHASE 11-G-A102COMPOSITE FLOOR PLAN - 2ND FLOOR PHASE1DOOR ELEVATIONS AND DETAILS - EXISTING LOADING DOCK1-ELD-A602DETAILS - NEW INTERIOR AND EXTERIOR ELEVATORS1-GE-A501FINISH PLANS - NEW INTERIOR AND EXTERIORELEVATORS1-GE-A701LANDSCAPE PLAN PHASE 1L1.06INTERIOR ELEVATIONS AND FINISH DETAILS - NEWINTERIOR ELEVATOR1-NIE-A703DEMOLITION PLAN - EXISTING TERMINAL B 2ND FLOOR1-SA-A101ROADWAY SIGNAGE PLANC1.20X08-25-1709-06-1709-26-1708-11-1708-25-1709-06-1709-26-1708-11-1708-25-1709-06-1709-26-17XXXXXXXXXXXXXXXXXXXXX09-28-1709-28-1709-28-17500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:46:56 AMG102.1PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINDEX OF DRAWINGS - PHASE 107-14-2017S12014REVISIONS# DATEDESCRIPTIONBYCONFORMED SET4
WINDOW SCHEDULE AND KEY PLAN - SCREENING AREA1-SA-A603FINISH PLAN AND SCHEDULE - SCREENING AREA1-SA-A701FINISH PLAN - SCREENING AREA CONTINUED1-SA-A7021-SA-A711FLOOR PLAN AND WALL SECTIONS - BAGGAGE CLAIM 31-BC3-A101FLOOR PLAN - NEW FIRE RISER ROOM AND BLOCKHOUSE ADDITION1-BC3-A102REFLECTED CEILING PLAN - BAGGAGE CLAIM 31-BC3-A103REFLECTED CEILING PLAN - BAGGAGE CLAIM 1 & 21-BC3-A104INTERIOR ELEVATIONS - STOREFRONT - SCREENINGAREA1-SA-A712DEMOLITION PLAN - BAGGAGE CLAIM 31-BC3-A100REFLECTED CEILING PLAN - BAGGAGE CLAIM 3EXISTING EXTERIOR CANOPY1-BC3-A105ENLARGED FLOOR PLAN AND INTERIOR ELEVATIONS -BAGGAGE CLAIM 3 RESTROOMS1-BC3-A401DOOR SCHEDULE AND KEY PLAN - BAGGAGE CLAIM 3AND F.I.S. CUSTOMS1-BC3-A601FINISH PLAN AND SCHEDULE - BAGGAGE CLAIM 31-BC3-A701FLOOR PLAN - F.I.S. CUSTOMS - SECURITY EXIT1-FIS-A101INTERIOR ELEVATIONS - F.I.S. CUSTOMS - SECURITYEXIT1-FIS-A711CANOPY FLOOR PLAN1-SPL-A101CANOPY ROOF PLAN1-SPL-A102CANOPY ELEVATIONS1-SPL-A201CANOPY SECTIONS1-SPL-A301STRUCTURALCOMPOSITE FIRST FLOOR PLAN - STRUCTURALSCOPE OF WORK1-S001COMPOSITE SECOND FLOOR PLAN - STRUCTURALSCOPE OF WORK1-S002LOADING DOCK BUILDING FOUNDATION PLAN1-S101CIRCULAR ENTRY SIGN - TYPE "I" FRAMING PLANAND STEEL CONNECTION DETAILS1-S205ABBREVIATIONS AND STRUCTURAL NOTES1-S0031-S004ABBREVIATIONS AND STRUCTURAL NOTES1-S005WIND LOADING TABLES (C & C)LOADING DOCK BUILDING FOUNDATION SECTIONS &DETAILS1-S102ELEVATOR SHAFT STRUCTURAL PLAN AND FOOTINGSECTIONS1-S103ELEVATOR SHAFT FOOTING SECTIONS1-S104LOADING DOCK BUILDING ROOF FRAMING PLAN1-S201LOADING DOCK BUILDING ROOF FRAMINGSECTIONS & DETAILS1-S202ELEVATOR SHAFT FRAMING PLAN, SECTION ANDDETAILS1-S203ELEVATOR SHAFT FRAMING SECTIONS AND DETAILS1-S204BAGGAGE CLAIM NO. 3 EXISTING WALL DEMOLITION &PROPOSED FOUNDATION PLAN1-S1051-S106BAGGAGE CLAIM NO. 3 WALL OPENING STRUCTURALREINFORCEMENTINTERIOR ELEVATIONS RESTROOMS - SCREENING AREAFINISH PLAN - TERMINAL B1-SA-A703SCREENING BLDG. EXPANSION 2ND LEVEL AND ROOFFRAMING PLAN1-S302SCREENING BLDG. EXPANSION 2ND LEVEL FRAMINGSECTIONS AND DETAILS1-S303SCREENING BLDG. EXPANSION ROOF LEVELFRAMING SECTIONS AND DETAILS1-S304SCREENING BLDG. EXPANSION- DEMOLITION ANDFOUNDATION PLAN1-S301CIRCULAR ENTRY SIGN - TYPE "I" FRAMING SECTIONSAND DETAILS1-S206FIRE PROTECTION TABLES, SCHEDULES, ANDGENERAL NOTES1-G-FP001COMPOSITE SECOND FLOOR PLAN - PHASE 1 -FIRE PROTECTION1-G-FP102FLOOR PLAN - NEW LOADING DOCK - FIREPROTECTION1-LD-FP100FLOOR PLAN - EXISTING LOADING DOCK - 1STFLOOR - FIRE PROTECTION1-ELD-FP100FLOOR PLAN - SCREENING AREA - 1ST FLOOR -FIRE PROTECTION1-SA-FP100FLOOR PLAN - BAGGAGE CLAIM 3 - 1ST FLOOR - FIRE PROTECTION1-BC3-FP100ROOF PLAN - BAGGAGE CLAIM 3 - 1ST FLOOR - FIRE PROTECTION1-BC3-FP101FLOOR PLAN - BLOCK HOUSE - 1ST FLOOR - FIRE PROTECTION1-BH-FP100FLOOR PLAN - F.I.S. CUSTOMS - SECURITY EXIT - 1ST FLOOR - FIREPROTECTION1-FIS-FP100MECHANICAL GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS1-G-M001COMPOSITE FIRST FLOOR PLAN - PHASE 1 - MECHANICAL1-G-M101COMPOSITE SECOND FLOOR PLAN - PHASE 1 - MECHANICAL1-G-M102COMPOSITE ROOF PLAN - PHASE 1 - MECHANICAL1-G-M103FLOOR PLAN - NEW LOADING DOCK - MECHANICAL1-LD-M100FLOOR PLAN - EXISTING LOADING DOCK - 1ST FLOOR - MECHANICAL1-ELD-M100FLOOR PLAN - NEW EXTERIOR ELEVATOR - 1ST & 2ND FLOORS -MECHANICAL1-NEE-M100FLOOR PLAN - NEW INTERIOR ELEVATOR - 1ST & 2ND FLOORS - MECHANICAL1-NIE-M100FLOOR PLANS - SCREENING AREA - 1ST FLOOR - MECHANICAL1-SA-M100FLOOR PLAN - SCREENING AREA - 2ND FLOOR - MECHANICAL1-SA-M101ROOF PLAN - SCREENING AREA - MECHANICAL1-SA-M102ENLARGED FLOOR PLANS - SCREENING AREA - 2ND FLOOR - MECHANICAL1-SA-M401ENLARGED FLOOR PLANS - SCREENING AREA - 2ND FLOOR - MECHANICAL1-SA-M402ENLARGED FLOOR PLANS - SCREENING AREA - 2ND FLOOR - MECHANICAL1-SA-M403FLOOR PLAN - BAGGAGE CLAIM 3 - 1ST FLOOR - MECHANICAL1-BC3-M100FLOOR PLAN - BLOCK HOUSE - 1ST FLOOR - MECHANICAL1-BH-M100FLOOR PLAN - F.I.S. CUSTOMS - SECURITY EXIT - 1ST FLOOR - MECHANICAL1-FIS-M100FIRE PROTECTIONCOMPOSITE FIRST FLOOR PLAN - PHASE 1 - FIREPROTECTION1-G-FP101FIRE PROTECTION DETAILS - 11-G-FP500FIRE PROTECTION DETAILS - 21-G-FP501FLOOR PLANS - NEW EXTERIOR ELEVATOR - 1ST & 2NDFLOORS - FIRE PROTECTION1-NEE-FP100FLOOR PLANS - NEW INTERIOR ELEVATOR - 1ST & 2NDFLOORS - FIRE PROTECTION1-NIE-FP100FLOOR PLAN - SCREENING AREA - 2ND FLOOR -FIRE PROTECTION1-SA-FP101FLOOR PLAN - BAGGAGE CLAIM 1 & 2 - 1ST FLOOR - FIRE PROTECTION1-BC3-FP102MECHANICAL SCHEDULES - 11-G-M300MECHANICAL DETAILS - 11-G-M500MECHANICAL DETAILS - 21-G-M501MECHANICAL DETAILS - 31-G-M502MECHANICAL DETAILS - 41-G-M503MECHANICAL DETAILS - 51-G-M504MECHANICAL SEQUENCE OF OPERATION - 11-G-M600MECHANICAL SEQUENCE OF OPERATION - 21-G-M601MECHANICALFLOOR PLAN - NEW LOADING DOCK - FIRE ALARM1-LD-FA100FLOOR PLAN - BLOCK HOUSE - PHASE 1 - FIRE ALARM1-BH-FA100ALARM PLAN GENERAL NOTES AND SYMBOLS1-FA-001FLOOR PLAN - SCREENING AREA - 2ND FLOOR - FIRE ALARM1-SA-FA101FLOOR PLAN - BAGGAGE CLAIM 3 - 1ST FLOOR - FIRE ALARMFLOOR PLAN F.I.S. - CUSTOMS - SECURITY EXIT - 1ST FLOOR - FIREALARM1-FIS-FA1001-BC3-FA100FIRE ALARMSTRUCTURAL STAIRS ENLARGED PLAN, SECTIONSAND DETAILS1-S401EXISTING LOADING DOCK SLAB DEMOLITION PLAN1-S501EXISTING LOADING DOCK FOUNDATION PLAN ANDDETAILS1-S502TYPICAL LIGHT GAUGE FRAMING DETAILS FOR DOORAND WINDOWS1-S503STEEL FRAMING CONNECTIONS AND DETAILS1-S601CAMPUS CONTROLS RETROFIT - PHASE 1 - SYSTEM STRUCTURE1-C-M100CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 11-C-M101CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 21-C-M102CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 31-C-M103CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 41-C-M104CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 51-C-M105CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 61-C-M1061-C-M1071-C-M1081-C-M1091-C-M1101-C-M1111-C-M1121-C-M1131-C-M114FIRE ALARM RISER DIAGRAM1-G-FA002COMPOSITE FIRST FLOOR PLAN - PHASE 1 - FIRE ALARM1-G-FA101COMPOSITE SECOND FLOOR PLAN - PHASE 1 - FIRE ALARM1-G-FA102DEMOLITION FLOOR PLAN - PHASE 1 - FIRE ALARM1-GD-FA100DEMOLITION FLOOR PLAN - PHASE 1 - FIRE ALARM1-GD-FA101DEMOLITION FLOOR PLAN - PHASE 1 - FIRE ALARM1-GD-FA102FLOOR PLAN - EXISTING LOADING DOCK - 1ST FLOOR - FIRE ALARM1-ELD-FA100FLOOR PLANS - NEW EXTERIOR ELEVATOR - PHASE 1 - FIRE ALARM1-NEE-FA100FLOOR PLANS - NEW INTERIOR ELEVATOR - PHASE 1 - FIRE ALARM1-NIE-FA101FLOOR PLANS - SCREENING AREA - PHASE 1 - FIRE ALARM1-SA-FA102CAMPUS CONTROLS RETROFIT - PHASE 1 - SEQUENCE OFOPERATION - 1CAMPUS CONTROLS RETROFIT - PHASE 1 - SEQUENCE OFOPERATION - 2CAMPUS CONTROLS RETROFIT - PHASE 1 - SEQUENCE OFOPERATION - 3CAMPUS CONTROLS RETROFIT - PHASE 1 - SEQUENCE OFOPERATION - 4CAMPUS CONTROLS RETROFIT - PHASE 1 - SEQUENCE OFOPERATION - 5CAMPUS CONTROLS RETROFIT - PHASE 1 - SEQUENCE OFOPERATION - 61-C-M1151-C-M116FLOOR PLAN - BAGGAGE CLAIM 1 & 2 - 1ST FLOOR - FIRE ALARM1-BC3-FA101MECHANICAL SCHEDULES - 21-G-M301MECHANICAL SEQUENCE OF OPERATION - 31-G-M602DEMOLITION FLOOR PLANS - PHASE 1 - MECHANICAL1-GD-M100DEMOLITION FLOOR PLANS - PHASE 1 - MECHANICAL1-GD-M101CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 7CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 8CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 9CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 10FLOOR PLAN - SCREENING AREA - 1ST FLOOR - FIRE ALARM1-SA-FA10008-11-1708-25-1709-06-1709-26-1708-11-1708-25-1709-06-1709-26-1708-11-1708-25-1709-06-1709-26-17ARCHITECTURAL CONTINUEDXXXXXXXXXXX1-S107CANOPY FOUNDATION PLAN1-S108CANOPY FOUNDATION DETAILSXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX09-28-1709-28-1709-28-17500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:47:07 AMG102.2PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINDEX OF DRAWINGS - PHASE 107-14-2017S12014REVISIONS# DATEDESCRIPTIONBYCONFORMED SET5
BAGGAGE CLAIM 3 - NEW FIRE RISER ROOM - FIRST FLOORELECTRICAL PLAN1-BC3-E102BAGGAGE CLAIM 3 - FIRST FLOOR - LIGHTING PLAN1-BC3-E201BAGGAGE CLAIM 3 - SOUTH ENTRANCE - LIGHTING PLAN1-BC3-E203BAGGAGE CLAIM 1 & 2 - LIGHTING PLAN1-BC3-E202WEST PARKING - GARAGE - ELECTRICAL PLAN1-WP-E101WEST SIDE PARKING - LOT B - ELECTRICAL PLAN1-WP-E102ONELINE RISER DIAGRAMS1-E601PANEL SCHEDULES1-E701PANEL SCHEDULES1-E702PANEL SCHEDULES1-E703PANEL SCHEDULES1-E705DETAILS1-E801LIGHTNING PROTECTION DETAILS1-E802DEMOLITION FLOOR PLANS - PHASE 1 - PLUMBING1-GD-P100PLUMBING LEGEND, GENERAL NOTES, AND ABBREVIATIONS1-G-P001PLUMBING SCHEDULE - 11-G-P300PLUMBING DETAILS - 11-G-P500PLUMBING DETAILS - 21-G-P501COMPOSITE FIRST FLOOR PLAN - PHASE 1 - PLUMBING1-G-P101COMPOSITE SECOND FLOOR PLAN - PHASE 1 - PLUMBING1-G-P102COMPOSITE ROOF PLAN - PHASE 1 - PLUMBING1-G-P103FLOOR PLAN - NEW LOADING DOCK - PLUMBING - SANITARYWASTE1-LD-P100FLOOR PLAN - NEW LOADING DOCK - PLUMBING - DOMESTIC WATER1-LD-P101ROOF PLAN - NEW LOADING DOCK1-LD-P102FIS SECURITY EXIT - FIRST FLOOR - POWER PLAN1-FIS-E101FIS SECURITY EXIT - FIRST FLOOR - LIGHTING PLAN1-FIS-E201WEST SIDE PARKING - SITE LIGHTING PLAN1-WP-E201ONELINE RISER DIAGRAMS1-E602SSA SCREENING ONE-LINE DIAGRAM - POWER1-E603WEST PARKING LOT - ONE-LINE DIAGRAM1-E604LIGHTING CONTROL RISER DIAGRAM1-E605PANEL SCHEDULES - WEST MSB PANELS1-E700PANEL SCHEDULES - WEST PARKING1-E706PANEL SCHEDULES1-E707PANEL SCHEDULES1-E704ELECTRICAL NAME PLATE DETAILS1-E803PLUMBINGBLOCK HOUSE ADDITION - FIRST FLOOR - ELECTRICAL PLAN1-BH-E101ELECTRICAL GENERAL NOTES, ABBREVIATIONS, SYMBOLS1-E001LIGHTING SCHEDULE1-E002COMPOSITE DEMOLITION PLAN - 1ST FLOOR - ELECTRICAL1-G-E100COMPOSITE DEMOLITION PLAN - 2ND FLOOR - ELECTRICAL1-G-E101COMPOSITE PLAN - 1ST FLOOR -ELECTRICAL1-G-E102COMPOSITE PLAN - 2ND FLOOR -ELECTRICAL1-G-E103NEW LOADING DOCK - ELECTRICAL SITE PLAN1-LD-E100NEW LOADING DOCK - FIRST FLOOR - POWER PLAN1-LD-E101NEW LOADING DOCK- FIRST FLOOR - LIGHTING PLAN1-LD-E201NEW LOADING DOCK- FIRST FLOOR - LIGHTING PHOTOMETRIC PLAN1-LD-E202NEW LOADING DOCK - ROOF - LIGHTNING PLAN1-LD-E401EXISTING LOADING DOCK - FIRST FLOOR - DEMOLITION ELECTRICAL PLAN1-ELD-E100EXISTING LOADING DOCK - FIRST FLOOR ELECTRICAL PLAN1-ELD-E101NEW ELEVATOR 1 - FIRST & SECOND FLOOR - ELECTRICAL ENLARGED PLANS1-NEE-E101SCREENING AREA EXPANSION - SECOND FLOOR - ELECTRICALDEMOLITION PLAN1-SA-E101SCREENING SECURITY AREA - SECOND FLOOR - POWER DEMOLITION PLAN1-SA-E102SCREENING TBI & SAA AREA - SECOND FLOOR - POWER DEMOLITION PLAN1-SA-E103ELECTRICAL SCREENING AREA EXPANSION - ROOF PLAN1-SA-E104SCREENING AREA EXPANSION - SECOND FLOOR - ELECTRICAL PLAN1-SA-E110SCREENING AREA EXPANSION - SECOND FLOOR - POWER OFFICE PLAN1-SA-E111SCREENING AREA EXPANSION - SECOND FLOOR - POWERSCREENING PLAN1-SA-E112SCREENING AREA - SECOND FLOOR - LIGHTING DEMOLITION PLAN1-SA-E200SCREENING AREA - SECOND FLOOR - LIGHTING PLAN1-SA-E210SCREENING AREA - SECOND FLOOR - LIGHTING PLAN1-SA-E211SCREENING AREA - ROOF - LIGHTNING PLAN1-SA-E410BAGGAGE CLAIM 3- FIRST FLOOR-ELECTRICAL DEMOTION PLAN1-BC3-E100BAGGAGE CLAIM 3 - FIRST FLOOR - POWER PLAN1-BC3-E101ELECTRICALOUTBOUND ELEVATOR - 1ST AND 2ND FLOOR - ELECTRICALENLARGED PLANS1-NIE-E101CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 1CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 2CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 3CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 4CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 5CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 6CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 71-C-M1171-C-M1181-C-M1191-C-M1201-C-M1211-C-M1221-C-M1231-C-M124PANEL SCHEDULES - BLOCK HOUSE1-E708CAMPUS CONTROLS RETROFIT - PHASE 1 - 1ST FLOOR - 11CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 8CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 9CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 10CAMPUS CONTROLS RETROFIT - PHASE 1 - 2ND FLOOR - 111-C-M1251-C-M1261-C-M1271-C-M128PANEL SCHEDULES1-E709TA001CCTV - NOTES AND SYMBOL LEGENDTA110CCTV - EXISTING OVERALL 1ST FLOOR PLANCCTV1-TA211CCTV PROPOSED 1ST FLOOR PLAN1-TA211ECCTV PROPOSED 1ST FLOOR ENLARGED PLAN1-TA220CCTV PROPOSED OVERALL 2ND FLOOR PLAN1-TA222CCTV PROPOSED 2ND FLOOR PLAN1-TA223CCTV PROPOSED 2ND FLOOR PLAN1-TA224CCTV PROPOSED 2ND FLOOR PLAN1-TA225CCTV PROPOSED 2ND FLOOR PLAN1-TA300CCTV DETAILSTY001 ACS - NOTES AND SYMBOL LEGENDACCESS CONTROL SYSTEMSTY110 ACS EXISTING OVERALL 1ST FLOOR PLAN1-TY112 ACS EXISTING AND DEMO 1ST FLOOR PLAN1-TY115 ACS EXISTING AND DEMO 1ST FLOOR PLANTY120 ACS EXISTING OVERALL 2ND FLOOR PLANLOADING DOCK - PLUMBING RISERS1-LD-P500FLOOR PLAN - NEW EXTERIOR ELEVATOR - 1ST FLOOR - PLUMBING1-NEE-P100FLOOR PLAN - OUTBOUND ELEVATOR - 1ST FLOOR - PLUMBING1-NIE-P100FLOOR PLAN - SCREENING AREA - 2ND FLOOR - PLUMBING1-SA-P101ENLARGED FLOOR PLANS - SCREENING AREA - 2ND FLOOR - PLUMBING1-SA-P400SCREENING AREA - PLUMBING RISERS1-SA-P500FLOOR PLAN - BAGGAGE CLAIM 3 - 1ST FLOOR - PLUMBING1-BC3-P100ENLARGED FLOOR PLANS AND RISERS - BAGGAGE CLAIM 3 - PLUMBING1-BC3-P400FLOOR PLAN AND RISERS - BLOCK HOUSE - 1ST FLOOR - PLUMBING1-BH-P100ROOF PLAN - SCREENING AREA - PLUMBING1-SA-P102ROOF PLAN - SCREENING AREA - PLUMBING1-SA-P401MECHANICAL CONTINUEDFLOOR PLAN - SCREENING AREA - 1ST FLOOR - PLUMBING1-SA-P100TA115CCTV - EXISTING AND DEMO 1ST FLOOR PLANTA210TA122CCTV - EXISTING AND DEMO 2ND FLOOR PLANTA123CCTV - EXISTING AND DEMO 2ND FLOOR PLANTA124CCTV - EXISTING AND DEMO 2ND FLOOR PLANTA125CCTV - EXISTING AND DEMO 2ND FLOOR PLANTA1201-TA215CCTV PROPOSED 1ST FLOOR PLAN1-TY113 ACS EXISTING AND DEMO 1ST FLOOR PLANCCTV PROPOSED OVERALL 1ST FLOOR PLANCCTV PROPOSED OVERALL 2ND FLOOR PLANLOADING DOCK - PLUMBING RISERS1-LD-P50108-11-1708-25-1709-06-1709-26-1708-11-1708-25-1709-06-1709-26-1708-11-1708-25-1709-06-1709-26-17XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX09-28-1709-28-1709-28-17500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:47:18 AMG102.3PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINDEX OF DRAWINGS - PHASE 107-14-2017S12014REVISIONS# DATEDESCRIPTIONBYCONFORMED SET6
W100 GENERAL NOTES, STANDARDS & KEY PLANW101 NEW SIGN REQUIREMENTSWAYFINDINGW201 SIGN TYPE DETAILS A - CW202 SIGN TYPE DETAILS D - FW203 SIGN TYPE DETAILS G-HW204 SIGN TYPE DETAILS GW400PHASE 1 DEMOLITION AND TEMPORARY SIGNAGESCHEDULEW401 PHASE 1 DEMOLITION PLANSW402 PHASE 1 TEMPORARY SIGNAGE PLAN - BAGGAGE CLAIM 1-3W403 PHASE 1 TEMPORARY SIGNAGE PLAN - SCREENING AREAW404W405 PHASE 1 NEW SIGNAGE SCHEDULEB2.1.04 PLAN- CD3 EXPANSIONB2.1.09 PLAN- CD3 TEMP LINEDEMOB5.1.07 PLAN - CD3 CONTROL DEVICES1-TY123 ACS EXISTING AND DEMO 2ND FLOOR PLAN1-TY124 ACS EXISTING AND DEMO 2ND FLOOR PLAN1-TY125 ACS EXISTING DEMO 2ND FLOOR PLANTY210 ACS PROPOSED OVERALL 1ST FLOOR PLAN1-TY211 ACS PROPOSED 1ST FLOOR PLAN1-TY211E ACS PROPOSED 1ST FLOOR ENLARGED PLAN1-TY212 ACS PROPOSED 1ST FLOOR PLAN1-TY215 ACS PROPOSED 1ST FLOOR PLANTY220 ACS PROPOSED OVERALL 2ND FLOOR PLAN1-TY222 ACS OVERALL 2ND FLOOR PLAN1-TY223 ACS OVERALL 2ND FLOOR PLAN1-TY224 ACS OVERALL 2ND FLOOR PLAN1-TY225 ACS OVERALL 2ND FLOOR PLANTY300 ACS DETAILSTY301 ACS DETAILSTY302 ACS DETAILSTY303 ACS DETAILSTY304 ACS DETAILSTELECOMMUNICATIONS1-TA000TELECOMMUNICATIONS LEGEND, SYMBOLS ANDABBREVIATIONS1-TD100 STRUCTURAL CABLING SYSTEM OVERALL FIRST FLOOR PLAN1-TD101 STRUCTURAL CABLING SYSTEM PARTIAL FIRST FLOOR PLAN1-TD102 STRUCTURAL CABLING SYSTEM PARTIAL FIRST FLOOR PLAN1-TD103 STRUCTURAL CABLING SYSTEM PARTIAL FIRST FLOOR PLAN1-TD104 STRUCTURAL CABLING SYSTEM PARTIAL FIRST FLOOR PLAN1-TD105 STRUCTURAL CABLING SYSTEM PARTIAL FIRST FLOOR PLAN1-TD106 STRUCTURAL CABLING SYSTEM PARTIAL FIRST FLOOR PLAN1-TD107 STRUCTURAL CABLING SYSTEM PARTIAL FIRST FLOOR PLAN1-TD200STRUCTURAL CABLING SYSTEM OVERALL SECOND FLOORPLAN1-TD201STRUCTURAL CABLING SYSTEM PARTIAL SECOND FLOORPLAN1-TD202STRUCTURAL CABLING SYSTEM PARTIAL SECOND FLOORPLAN1-TD203STRUCTURAL CABLING SYSTEM PARTIAL SECOND FLOOR PLAN1-TD204STRUCTURAL CABLING SYSTEM PARTIAL SECOND FLOORPLAN1-TD205STRUCTURAL CABLING SYSTEM PARTIAL SECOND FLOORPLAN1-TD301EXISTING COMMUNICATIONS ROOM LAYOUT AND RACKELEVATIONS1-TD303EXISTING COMMUNICATIONS ROOM LAYOUT AND RACKELEVATIONS1-TD305NEW COMMUNICATIONS ROOM LAYOUT AND RACKELEVATIONS1-TD306EXISTING COMMUNICATIONS ROOM LAYOUT AND RACKELEVATIONS1-TD307EXISTING COMMUNICATIONS ROOM LAYOUT AND RACKELEVATIONS1-TD308 EXISTING COMMUNICATIONS ROOM LAYOUT AND RACK ELEVATIONS1-TD310NEW COMMUNICATIONS ROOM LAYOUT AND RACKELEVATIONS1-TD400STRUCTURAL CABLING SYSTEM TELECOM GROUNDINGRISER DIAGRAM1-TD401FIBER RISER DIAGRAM COMMUNICATIONS ROOM LOGICDIAGRAM1-TN001ADMIN NETWORK SYSTEM LOGIC DIAGRAM1-TN002SECURITY NETWORK SYSTEM LOGIC DIAGRAM1-TN003AWW AREA NETWORK SYSTEM LOGIC DIAGRAM1-TT001TELEPHONY SYSTEM LOGIC DIAGRAM1-TC100DAS OVERALL FIRST FLOOR PLAN1-TC103DAS PARTIAL FIRST FLOOR PLAN1-TC200DAS OVERALL SECOND FLOOR PLAN1-TC203DAS PARTIAL SECOND FLOOR PLAN1-TC300DAS EQUIPMENT MATRIX1-TI100APS OVERALL FIRST FLOOR PLAN1-TI100AAPS OVERALL ZONE LAYOUT - FIRST FLOOR PLAN1-TI102APS PARTIAL FIRST FLOOR PLAN1-TI103APS PARTIAL FIRST FLOOR PLAN1-TI104APS PARTIAL FIRST FLOOR PLAN1-TI200APS OVERALL SECOND FLOOR PLAN1-TI200AAPS OVERALL ZONE LAYOUT - SECOND FLOOR PLAN1-TI201APS PARTIAL SECOND FLOOR PLAN1-TI202APS PARTIAL SECOND FLOOR PLAN1-TI203APS PARTIAL SECOND FLOOR PLAN1-TI204APS PARTIAL SECOND FLOOR PLAN1-TI301AUDIO PAGING SYSTEM FUNCTIONAL DIAGRAM1-TI401APS SPEAKER MOUNTING DETAILS1-TN100EVIDS OVERALL FIRST FLOOR PLAN1-TN200EVIDS OVERALL SECOND FLOOR PLAN1-TN202EVIDS PARTIAL SECOND FLOOR PLAN1-TN203EVIDS PARTIAL SECOND FLOOR PLAN1-TN300EVIDS FIDS / BIDS SYSTEM LOGIC DIAGRAM1-TN301EVIDS LOGIC DIAGRAM1-TN400EVIDS DISPLAY TYPE REFERENCES1-TN401EVIDS TYPE AND QUANTITY SCHEDULE DISPLAY TYPESAND MOUNTING DETAILS1-TN402EVIDS TYPE AND QUANTITY SCHEDULE DISPLAY TYPESAND MOUNTING DETAILSBAGGAGE BELTB2.1.03PLAN - CD3 CURRENT CONDITIONACCESS CONTROL CONTINUED1-TY122 ACS EXISTING AND DEMO 2ND FLOOR PLAN1-TY213 ACS PROPOSED 1ST FLOOR PLAN1-TA001TELECOMMUNICATIONS GENERAL NOTES1-TI205APS PARTIAL SECOND FLOOR PLAN1-TI300AUDIO PAGING SYSTEM LOGIC DIAGRAMW200 SIGN TYPE DETAILS - TEMPORARY SIGNAGEW205 SIGN TYPE DETAILS G-HW301 MASTER SHEET LAYOUT PLAN - PHASINGPHASE 1 TEMPORARY SIGNAGE PLAN - GATES 11-16W406 PHASE 1 NEW SIGNAGE PLAN - BAGGAGE CLAIM 1-3W407 PHASE 1 NEW SIGNAGE PLAN - SCREENING AREAW408 PHASE 1 NEW SIGNAGE PLAN - GATES 11-16SIGNAL IMPROVEMENTST-1 COVER SHEETT-2 SUMMARY OF PAY ITEMST-3 SIGNAL NOTEST-4 SIGNAL PLANT-5 MAST ARM TABULATIONT-6 STANDARD MAST ARM ASSEMBLIEST-7 GUIDSIGN WORKSHEETD-1 SPECIAL DITCH DETAIL SHEETE-1 TRAFFIC SIGNAL POWER PLANS-1 SIGNING AND PAVEMENT MARKING PLANTCP-1 TRAFFIC CONTROL NOTESTCP-2 FDOT INDEX MOT SHEETSTCP-3 FDOT INDEX MOT SHEETSTCP-4 FDOT INDEX MOT SHEETSTCP-5 FDOT INDEX MOT SHEETSTCP-6 FDOT INDEX MOT SHEETSTCP-7 FDOT INDEX MOT SHEETSTCP-8 FDOT INDEX MOT SHEETS08-11-1708-25-1709-06-1709-26-1708-11-1708-25-1709-06-1709-26-1708-11-1708-25-1709-06-1709-26-171-TY600 ACS DOOR SCHEDULEXXXXXB.IS.01ABBREVIATIONS GENERAL NOTES AND DRAWING INDEXB.IS.02CONVEYOR LEGENDS AND SYMBOLSB.IS.03MOTOR MANIFESTB5.1.00 ELECTRICAL DEVICE STANDARDSB6.1.00 GENERAL DETAIL DRAWING (TYPICAL HANGING)B6.1.01 GENERAL DETAIL DRAWING (TYPICAL CONVEYOR)B6.1.02 GENERAL DETAIL DRAWING (POINT LOADS)B6.1.03 GENERAL DETAIL DRAWING (DOOR DETAILS)B6.1.04 GENERAL DETAIL DRAWING (HANGING ATTACHMENTS)XXXXXXXXX09-28-1709-28-1709-28-17500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:47:28 AMG102.4PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINDEX OF DRAWINGS - PHASE 107-14-2017S12014REVISIONS# DATEDESCRIPTIONBYCONFORMED SET7
ELEVATIONCL500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:09:16 PMG105PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAGENERAL INFORMATION07-14-2017S120141110'-0"KEY NOTEREVISION TAGDOOR TAGWINDOW TAGPARTITION TYPEROOM NAME & NUMBEREQUIPMENT REFERENCENORTH ARROWCOLUMN DESIGNATION& GRIDLINEPROPOSED ELEVATIONDIMENSION LINESELEVATION REFERENCESECTION REFERENCEDETAIL INDICATORBREAK LINECENTER LINEA711. GENERAL CONTRACTOR SHALL FIELD SURVEY LOCATION AND VERIFY ALL EXISTINGCONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BEREPORTED TO THE ARCHITECT.2. NOTIFY THE ARCHITECT IN WRITING OF ANY UNEXPECTED CONDITIONS THAT ARE UNCOVEREDAFTER BEGINNING WORK.3. GENERAL CONTRACTOR SHALL COMPLETE ALL WORK AS INDICATED ON THESE PLANS UNLESSOTHERWISE INDICATED.4. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS REQUIRED BY ONE SHALL BEAS BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OFTHE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS . NOTIFY THE ARCHITECT FORRESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION.5. GENERAL CONTRACTOR SHALL OBTAIN CONSTRUCTION PERMIT, APPROVALS, INSPECTIONS,CERTIFICATE FOR COMPLIANCE, AND ASSIST WITH THE CERTIFICATE OF OCCUPANCY ASREQUIRED UNLESS OTHERWISE NOTED.6. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS OTHER THAN GENERAL BUILDINGPERMITS REQUIRED FOR SUCH WORK SHOWN ON THE DRAWINGS. SUCH PERMITS SHALL BEOBTAINED BEFORE STARTING THE WORK. SEPARATE PERMITS ARE REQUIRED FOR THEINSTALLATION OF ALL EXTERIOR SIGNAGE. 7. GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY FACILITIES DURING CONSTRUCTIONFOR THE COMPLETE BUILDING OPERATION. THIS SHALL BE TEMPORARY ACCESS, EXIT,CORRIDORS, LIGHTING, FIRE PROTECTION, MAIN CORRIDOR PROTECTION, A/C & ALLINFRASTRUCTURE REQUIRED DURING THE FINAL STORE OPERATION.8. GENERAL CONTRACTOR SHALL REMOVE ALL TEMPORARY ITEMS AT THE COMPLETION OF WORKAS REQUIRED.9. GENERAL CONTRACTOR SHALL MAINTAIN ON SITE AT ALL TIMES, ALL APPROVED DRAWINGSINCLUDING ALL REVISIONS AND ADDENDA.10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS ANDREQUIREMENTS DURING CONSTRUCTION.11. AFTER COMPLETION, GENERAL CONTRACTOR SHALL CLEAN WHERE EVER SUCH CLEANING ISREQUIRED, INCLUDING AREAS OF THE BUILDING MADE DIRTY BY CONSTRUCTION WORK. REMOVEFROM THE PREMISES TRASH, TOOLS, EQUIPMENT AND EXCESS CONSTRUCTION MATERIALS.12. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE VARIOUS TRADE TOCOMPLETE THE WORK OUTLINED IN THESE DOCUMENTS , INCLUDING ITEMS WITHIN THE SPACEABOVE THE CEILINGS (STRUCTURAL MEMBERS, CONDUITS, MECHANICAL DUCTS, INSULATION,RECESSED LIGHT FIXTURES, AND CEILING CONSTRUCTION DIMENSIONS, ETC.) THE CONTRACTORSHALL BE RESPONSIBLE TO MAINTAIN THE FINISHED CEILING HEIGHT ABOVE THE FLOOR ASINDICATED IN THESE DRAWINGS FOR THE VARIOUS ROOMS AND AREAS.13. GENERAL CONTRACTOR SHALL PERFORM ALL WORK IN CONFORMITY WITH THOSE LAWSHAVING JURISDICTION WEATHER OR NOT SUCH WORK IS SPECIFICALLY SHOWN ON THESEDRAWINGS.14. CONTRACTOR WILL VERIFY WITH THE S.A.A., THE LOCATION OF ALL INFRASTRUCTURE, EVEN IF THEY ARE NOT SHOWN ON DRAWINGS.15. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY PARTITION WALLS IF THEY AREREQUIRED DURING THE CONSTRUCTION PROCESS.16. GENERAL CONTRACTOR SHALL INCLUDE FURNISHING ALL MATERIALS EQUIPMENT, TOOLS,LABOR AND SERVICES NECESSARY FOR COMPLETION OF THE PROJECT.17. GENERAL CONTRACTOR SHALL PERFORM ALL WORK ALL WORK IN CONFORMITY WITH THOSELAWS HAVING JURISDICTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY SHOWN ON THESEDRAWINGS.18. SHOP DRAWINGS:A. SUBMIT A SCHEDULE OF SHOP DRAWINGS PRIOR TO COMMENCING WORK.B. SUBMIT SHOP DRAWINGS FOR ARCHITECTS REVISION WHERE REQUIRED BY PLANSANDSPECIFICATIONS, WITH AMPLE TIME TO REVIEW AND APPROVE.C. ALL SHOP DRAWINGS, INCLUDING EQUIPMENT AND MATERIALS, SHALL BE REVIEWED ANDAPPROVED BY THE ARCHITECT PRIOR TO ORDERING OF FABRICATION.19. GENERAL CONTRACTOR TO SUBMIT TIMEFRAME & CONSTRUCTION PHASES SCHEDULE.20. GENERAL CONTRACTOR TO PROVIDE OWNER WITH ONE COMPLETE SET OF ACCURATE,FULL-SIZED AS-BUILT RECORD DRAWINGS FOR PERMANENT RECORD, AND ELECTRONIC VERSION IN AUTOCAD.21. FULLY WARRANTY ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR 2 YEAR FROM DATEOF ACCEPTANCE. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUNDDEFECTIVE DURING WARRANTY PERIOD. EXTEND ALL MANUFACTURER'S WARRANTIES TO THEOWNER.ABBREVIATIONS101ROOM5A5.2#NAME5A5.2STANDARD SYMBOLSAA000A5A5.21. DRAWINGS ARE IN INCHES UNLESS OTHERWISE NOTED.2. DIMENSIONS ARE GIVEN TO FACE OF CONCRETE PRECAST, FACE OF CONCRETEWITHOUT FINISH, FACE OF CMU WITHOUT FINISH AND FACE OF METAL STUD.3. PERFORM WORK IN ACCORDANCE WITH ALL APPLICABLE LOCAL CODES ANDREGULATORY REQUIREMENTS.4. KEEP THE PREMISES NEAT AND CLEAN AT ALL TIMES.5. PROTECT ALL AREAS ADJACENT TO THE WORK AREA, OR THROUGH WHICHMATERIALS MUST PASS, TO PREVENT DAMAGE RESULTING FROM CONSTRUCTIONOR MATERIALS' HANDLING. RESTORE TO EXISTING CONSTRUCTION ORIGINALCONSTRUCTION IF/WHEN DISTURBED.6. WHEN "APPROVED EQUAL", "EQUAL TO", OR OTHER GENERAL QUALIFYINGTERMS ARE USED, INTERPRET AS "TO BE REVIEWED BY THE ARCHITECT".7. FOLLOW THE MANUFACTURE'S STRICTEST WRITTEN RECOMMENDATIONS FORHANDLING, INSTALLATION, AND/OR APPLICATION OF ALL MATERIALS AND/ORPRODUCTS CONSISTENT WITH THE SKILL AND CARE NECESSARY FOR THEORDERLY PROGRESS OF WORK.8. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN.9. ALL FLOOR ELEVATIONS ARE GIVEN TO TOP OF CONC. SLAB (TOC), TOP OF WALL(TOW), OR TOP OF FLOOR FINISH (FEE), AS INDICATED.10. PERFORM ALL WORK IN A WORKMANLIKE MANNER.11. ALL GYPSUM BOARD WORK REQUIRES CORNER BEADS AND NEEDS TO BEAPPROVED BY THE ARCHITECT AND INSPECTOR BEFORE FINISHING IT.12. ALL DISTANCES, DATA AND EXISTING STRUCTURES AND UTILITIES ABOVE ORBELOW THE GROUND, WITHIN THE LIMITS OF THIS PROJECT SHALL BE CHECKED BYTHE CONTRACTOR. IN CASE OF CONFLICT, THE ARCHITECT SHALL BE NOTIFIEDIMMEDIATELY IN ORDER THAT CLARIFICATION MAY BE MADE.13. SITE SURVEY DRAWINGS ARE FOR INFORMATION ONLY. CONTRACTOR SHALLVERIFY AND PROVIDE ALL SITE SURVEY REQUIRED FOR THE WORK OF THISPROJECT.14. DETAILS ARE INTENDED TO SHOW METHOD AND MANNER OF ACCOMPLISHINGWORK. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS ANDSHALL BE INCLUDED AS PART OF THE CONTRACTORS WORK.GENERAL CONTRACTOR RESPONSIBILITYGENERAL NOTESABVABOVE FINISHED FLOORAFGABOVE FINISHED GRADEAPACCESS PANELACOUSACOUSTICALACTABOVEAFFACOUSTICAL CEILING TILEADDADDENDUMADHADHESIVEADJADJACENTADJTADJUSTABLEAGGAGGREGATEA/CAIR CONDITIONINGAHUAIR HANDLING UNITALTALTERNATEALUMALUMINUMANCHANCHOR, ANCHORAGEABANCHOR BOLTANODANODIZEDAPPROX APPROXIMATEARCHARCHITECTURALADAREA DRAINAUTOAUTOMATICAVGAVERAGEBSMNTBASEMENTBM BEAMBRG BEARINGBEL BELOWBET BETWEENBITBITUMINOUSBLK BLOCKBD BOARDBOT BOTTOMBW BOTTOM OF WALLBKT BRACKETBRK BRICKBRZBRONZEBLDGBUILDINGBUR BUILT-UP ROOFINGCAB CABINETCUH CABINET UNIT HEATERCPTCARPET (ED)CI CAST IRONCB CATCH BASINCLG CEILINGCEMCEMENTCTR CENTERCTCERAMIC TILECHBD CHALK BOARDCO CLEAN OUTCLR CLEARCLO CLOSETCOL COLUMNCOMP COMPRESS(ED), (ION),(IBLE)CONC CONCRETECMU CONCRETE MASONRY UNIT CONSTCONT. CONTINUOUSCONTR CONTRACTOR)CJTCONTROL JOINTCG CORNER GUARDCORR CORRIDORCTSK COUNTERSINKCRS COURSECYD CUBIC YARDDEPTDEPARTMENTDTLDETAILDIAG DIAGONALDIAM DIAMETERDIM DIMENSIONDW DISH WASHERDPR DISPENSERDISP DISPOSALDR DOORDO DOOR OPENINGDBL DOUBLEDA DOUBLE ACTINGDNDOWNDWR DRAWERDWGDRAWINGDFDRINKING FOUNTAINEAEACHEEASTELEC ELECTRIC(AL)EWC ELECTRIC WATER COOLEREL ELEVATIONELEV ELEVATOREMER EMERGENCYENC ENCLOSE (URE)ENG ENGINEER(ING)ENAM ENAMELEPT EPOXY PAINT(ED)EQ EQUALEQUIP EQUIPMENTEXH EXHAUSTEX EXISTINGEXP'D EXPOSEDEXP EXPANSION, EXPOSEDEJT EXPANSION JOINTEXT EXTERIOREIFS EXTERIOR INSULATION & FINISH EXTD EXTRUDEDFAB FABRICFWC FABRIC WALL COVERINGFOC FACE OF CONCRETEFOF FACE OF FINISHFOM FACE OF MASONRYFIN FINISH(ED)FF FINISHED FLOORFA FIRE ALARMFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFHC FIRE HOSE CABINETFPRF FIREPROOFFRFIRE RATINGFT FIRE TREATEDFIXT FIXTUREFLG FLASHINGFLR FLOOR(ING)FDFLOOR DRAINFLOUR FLUORESCENTFTG FOOTINGFDN FOUNDATIONFRM FRAMEFS FULL SIZEFURR FURRED (ING)GA GAGE, GAUGEGALVGALVANIZEDGC GENERAL CONTRACTORGLGLASS, GLAZINGGFRC GLASS FIBER REINFORCED CONCRETEGMU GLASS MASONRY UNITGTGLASS TILEGBGRAB BARGRD GRADE (ING)GRT GROUTGA GAGE, GAUGEGALV GALVANIZEDGC GENERAL CONTRACTORGLGLASS, GLAZINGGFRC GLASS FIBER REINFORCED CONCRETEGMU GLASS MASONRY UNITGT GLASS TILEGB GRAB BARGRD GRADE (ING)GRT GROUTGYP GYPSUMGWB GYPSUM WALL BOARDHP HANDICAPPEDHR HANDRAILHBD HARD BOARDHDW HARDWAREHDWDHARDWOODHD HEADHTG HEATINGHVAC HEATING/VENTILATING/AIR CONDITIONINGHTHEIGHTHPT HIGH POINTHCHOLLOW COREHMHOLLOW METALHB HOSE BIBBHORIZ. HORIZONTALIN INCHINCL INCLUDE(D), (ING)IC INSIDE CLEARID INSIDE DIAMETERINSUL INSULATE(D), (ION)INT INTERIORINVINVERTJANJANITORJTJOINT SJJOISTKITKITCHENLAMLAMINATELAVLAVATORYLCCLEAD COATED COPPERLHLEFT HANDLT LIGHTLS LIGHT SWITCHLWT LIGHT WEIGHTLTL LINTELLVR LOUVERMACH MACHINEMB MACHINE BOLTMH MAN HOLEMFR MANUFACTURE (ER)MAS MASONRYMO MASONRY OPENINGMTRL MATERIAL(S)MAX MAXIMUMMECH MECHANICALMC MEDICINE CABINETMED MEDIUMMTL METALMIN MINIMUMMISC MISCELLANEOUSMIR MIRRORMOD MODULARMR MOISTURE RESISTANT TMLDGMOLDING, MOLDINGMTD MOUNTEDMULL MULLIONNAT NATURALNOM NOMINALNCNONCORROSIVENNORTHNA NOT APPLICABLENICNOT IN CONTRACTNTS NOT TO SCALENO NUMBEROC ON CENTEROPNG OPENINGOPPOPPOSITEOPH OPPOSITE HANDOZ OUNCEODOUTSIDE DIAMETEROA OVERALLOH OVER HEADPTD PAINT(ED)PR PAIRPNL PANELPBD PARTICLE BOARDPTN PARTITIONPVMNT PAVEMENTPVRS PAVERSPERF PERFORATE(D)PLAS PLASTERP-LAMPLASTIC LAMINATEPL PLATEPWD PLYWOODPNT POINTPT PORCELAIN TILEPSF POUNDS PER SQUAREFOOTPSI POUNDS PER SQUARE INCHPFB PREFABRICATE(D)PM PRESSED METALPROP PROPOSEDQTY QUANTITYQT QUARRY TILERAD RADIUSRWL RAIN WATER LEADERREC RECESSEDREF REFERENCERFL REFLECT(ED), (IVE), (ING)REFRREFRIGERATORREINF REINFORCEREM REMOVEREQ'D REQUIREDRES RESILIENTRTRESILIENT TILERET RETURNRA RETURN AIRREV REVISIONRH RIGHT HANDRRISERRFG ROOFINGRD ROOF DRAINRM ROOMRO ROUGH OPENINGRB RUBBERSND SANITARY NAPKINDISPENSERSCHED SCHEDULESLNT SEALANTSECT SECTIONSHTH SHEATHINGSHT SHEETSM SHEET METALSVSHEET VINYLSH SHELF, SHELVINGSHRSHOWERSIM SIMILARSKLT SKYLIGHTSOG SLAB ON GRADESD SOAP DISPENSERSTC SOUND TRANSMISSIONCLASSSSOUTHSC SOLID CORESPEC SPECIFICATIONSASPRAY ACOUSTICSQ SQUARES/S STAINLESS STEELST STAIRSTD STANDARDSTA STATIONSTL STEELSTO STORAGESTRUC STRUCTURALSUSP SUSPENDEDSYS SYSTEMTKBD TACKBOARDTEL TELEPHONETEMP TEMPEREDTCTERRA COTTATZ TERAZZOTEX TEXTUREDTHK THICK(NESS)TPD TOILET PAPER DISPENSERT>ONGUE AND GROOVET&BTOP AND BOTTOMTCTOP OF CONCRETETF TOP OF FOOTINGTJ TOP OF JOISTTSL TOP OF SLABTST TOP OF STEELTW TOP OF WALLTW TOWEL BARTRTREADTRANS TRANSPARENTTYP TYPICALUC UNDERCUTUL UNDERWRITERUNO UNLESS NOTEDOTHERWISEUR URINALVERT VERTICALVG VERTICAL GRAINVIF VERIFY IN FIELDVEST VESTIBULEVPVENEER PLASTERVIN VINYLVCT VINYL COMPOSITION TILEVWC VINYL WALL COVERINGWC WATER CLOSETWH WATER HEATERWR WATER RESISTANTWP WATERPROOFINGWT WEIGHTWWF WELDED WIRE FABRICWWM WELDED WIRE MESHW WEST, WIDTH, WIDEWIN WINDOWWG WIRE GLASSWM WIRE MESHW/ WITHW/O WITH OUTWD WOODWPT WORK POINTWI WROUGHT IRONSYSTEMNPLANNORTHSAA SANFORD AIRPORT AUTHORITYRTU ROOF TOP UNITREVISIONS# DATE DESCRIPTION BYCONFORMED SET8
INTERIOR FINISHESWALL PANELINGPRODUCT: MARLITE SURFACE SYSTEMSMATERIAL: WOOD FINISH PLASTIC LAMINATECOLOR: TBDREVEAL: 1/4" NARROW REVEALCONTACT: DAN EGBERS 330-260-7633PRODUCT: MARLITE STANDARD FRPCOLOR: TBDPROVIDE TOP EDGE AND JOINT TREATMENT TO MATCHCONTACT: DAN EGBERS 330-260-7633CEILINGSCEILINGS THROUGHOUT UNLESS OTHERWISE NOTEDMFG:USG-CONTACT BILL MCCONNAUGHEY 407-883-3977STYLE: RADAR CLIMAPLUS SQSIZE: 2' X 2' X 5/8"COLOR: WHITEGYPSUM BOARD SOFFITSREFER TO PAINT COLORDOORSMFG:TBDSIZE:VARIES SEE PLANCOLOR: TBDART GLASS FINISHMFG: NUDO-MARLITE SYSTEMSMATERIAL: POLYCARB, MATTGRAPHICS BY OWNERCONTACT: DAN EGBERS 330-260-7633SINK FINISHVERGE SINK WITH WASH BAR TECHNOLOGYMFG: BRADLEYFINISH: EVERO NATURAL QUARTZ GEO SERIESCOLOR: CABOCONTACT: TOM MURPHY 407-841-9237COLUMNSPRODUCT: MARLITE SURFACE SYSTEMSMATERIAL: WOOD FINISH PLASTIC LAMINATECOLOR: TBDREVEAL: 1/4" NARROW REVEALCONTACT: DAN EGBERS 330-260-7633EXTERIOR FINISHESPAINTOVERALL BUILDING PAINTMFG:TBD COLOR:TBDTRIM PAINTMFG:TBDCOLOR:TBDACCENT PAINTMFG:TBDCOLOR:TBDACCENT PAINTMFG:TBDCOLOR:TBDCARPETNEW CARPETMFG:MANNINGTON COMMERCIALSTYLE: HUSKCOLOR: WOAD 35342BROADLOOMCONTACT: SHANNON POOLER407-489-2314BASEMFG:ROPPESIZE:6"COLOR: TBDMFG:ROPPESIZE:4"COLOR: TBDPRODUCT: BRUSHED STAINLESS STEEL @ MARLITE WALLS AND MILLWORK SIZE:1'-0" AND 6"(SEE DRAWINGS)TILEFLOOR TILEMFG:DALTILEPRODUCT: COLOR BODY PORCELAINSIZE: 24" x 24"STYLE: DIGNITARY SERIESCOLOR: DR11 GOVERNOR BLACKWALL TILEMFG:DALTILEPRODUCT: COLOR BODY PORCELAINSIZE:24" x 24" STYLE: DIGNITARY SERIESCOLOR: LUMINARY WHITEWALL TILE MFG:DALTILEPRODUCT: COLOR BODY PORCELAINSIZE:12" x 24" STYLE: DIGNITARY SERIESCOLOR: DR11 GOVERNOR BLACKCOVE BASEMFG: DALTILEPRODUCT: COLOR BODY PORCELAINSIZE: 6" X 12"STYLE: TO MATCH WALL TILECOLOR: TO MATCH WALL TILEPROVIDE COVE CORNER AT WALL TRANSITIONWALL TILEMFG:DALTILEPRODUCT: CERAMICSIZE:9" X 12"STYLE: HEATHLANDCOLOR: TBDWALL TILE-ACCENTMFG:DALTILEPRODUCT: CERAMICSIZE:2" X 10"STYLE: HEATHLANDCOLOR: TBDWALL TILE-BULLNOSEMFG:DALTILEPRODUCT: CERAMICSIZE:2" X 6"STYLE: HEATHLANDCOLOR: TBDFLOOR TILE MFG:DALTILEPRODUCT: CERAMICSIZE:12' x 12"STYLE: HEATHLANDCOLOR: TBDCOVE BASEMFG: DALTILEPRODUCT: CERAMICSIZE: 6" X 12"STYLE: HEATHLANDCOLOR: TBDPROVIDE COVE CORNER AT WALL TRANSITIONCONTACT: TERRY TAMPA/DALTILE407-402-0815TERRAZZO TILEPRODUCT:FRITZ TILESIZE:12" X 12"COLOR: CONCOURSE, #C520210CONTACT: BABS HEILESON386-668-0121PRODUCT:FRITZ TILESIZE:12" X 12"COLOR: ROMAN GRAY, #C521595CONTACT: BABS HEILESON386-668-0121PRODUCT:FRITZ TILESIZE:12" X 12"COLOR: GRAPHITE, #VP205504CONTACT: BABS HEILESON386-668-0121COUNTERPLASTIC LAMINATEMFG:WILSONARTCOLOR:TBDSOLID SURFACEMFG:TBDMFG:TBDVCT MFG: ARMSTRONGPRODUCT:EXCELONSIZE:12" X 12"COLOR: TBDMILLWORKMFG:MARLITECOLOR:TBDLOCATION: CABINETSMFG:MARLITECOLOR: TBDLOCATION: TBDINTERIOR PAINTALL WALLS UNLESS NOTED OTHERWISEMFG:SHERWIN WILLIAMSCOLOR: TBDACCENT - TBDMFG:SHERWIN WILLIAMSCOLOR: TBDACCENT - TBDMFG:SHERWIN WILLIAMSCOLOR: TBDACCENT - TBDMFG:SHERWIN WILLIAMSCOLOR: TBDDOOR TRIMMFG:SHERWIN WILLIAMSCOLOR: TBDCEILINGSMFG:SHERWIN WILLIAMSCOLOR: TBDEXPOSED BAR JOIST AND DECK CEILINGSMFG: SHERWIN WILLIAMSDRYFALL PAINTCOLOR: TBDC1B1B3EP4EP3EP2EP1P6P5P4P3P2P1T1T2T3T4T5T6T7T8TZ1TZ2TZ3PL1SS1M1M2W1CL1CL2V1W2B2NOTE: TILE GROUT BY MAPEI, COLOR TBD.T9POURED FLOORINGMFG: DUR-A-FLEXPRODUCT: POLYCRETECOLOR: TBDCONTACT: DREW DELLINGER 706-319-6527PFALL FINISHES LISTED ARE BASIS OF DESIGN UNLESS NOTED OTHERWISEP7GENERAL NOTES1. REFER TO CEILING PLANS FOR CEILING FINISH LOCATION.2. INTERIOR FINISHES THROUGHOUT SPACE SHALL COMPLY WITH BUILDING CODE FOR MINIMUM FLAME SPREAD. 3. (3) SAMPLES OF EACH SPECIFIED FINISH COLOR AND MATERIAL SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO COMMENCEMENT OF WORK.4. TYPICAL FLOOR COVERING TRANSITION SHALL BE AT CENTERLINE OF DOOR UNLESS NOTED OTHERWISE. REFER TO DETAILS AND SPECIFICATIONS FOR TRANSITION BETWEEN FINISHES. SUBMIT SAMPLES TO ARCHITECT FOR APPROVAL.5. CLEAN ALL WALLS PRIOR TO APPLYING NEW FINISH.6. PROTECT ALL NEW INSTALLED FINISHES AND EXISTING TO REMAIN FINISHES IN AREA OF WORK FROM DAMAGE AND DEBRIS. REFER TO SPECIFICATIONS FOR PROPER MAINTENANCE OF NEWLY INSTALLED FINISHES DURING ON GOING CONSTRUCTION.7, ALL DOORS AND FRAMES TO BE PAINTED SHALL BE SEMI-GLOSS FINISH. REFER TO DOOR SCHEDULE SHEET SERIES-A601.8. TILE GROUT BY MAPEI, COLORS TO BE DETERMINED.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:09:28 PMG106PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAGENERAL NOTES & PROJECT FINISHES07-14-2017S12014REVISIONS# DATE DESCRIPTION BYCONFORMED SET9
500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:09:40 PMG107PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAAIRPORT SAFETY AND SECURITY NOTES07-14-2017S12014GENERAL NOTES1.ALL CONTRACTOR VEHICLES AND TRAFFIC SHALL REMAIN WITHIN THE DESIGNATED STAGING AREA, CONSTRUCTIONLIMITS OR HAUL ROUTES.2.THE CONTRACTOR IS ADVISED THAT ALL EMPLOYEES WORKING INSIDE THE SECURE FENCE MUST CONFORM WITHALL AIRPORT SECURITY REQUIREMENTS AS OUTLINED IN SECTION 4 "SAFETY AND SECURITY REQUIREMENTS" OF THESPECIAL PROVISIONS.3.AIRPORT OPERATIONS STAFF SHALL HAVE THE AUTHORITY TO SUSPEND CONSTRUCTION OPERATIONS AT ANY TIME;DUE TO WEATHER, UNSAFE WORKING CONDITIONS OR WHEN DEEMED TO BE IN THE BEST INTEREST OF THE AIRPORT.4.THE AIRPORT WILL BE IN OPERATION DURING THE CONSTRUCTION OF THIS PROJECT. COORDINATION OF WORK WITHAIRPORT MANAGEMENT IS MANDATORY SO AS TO MINIMIZE IMPACTS ON AIRPORT OPERATIONS. OPERATION OF THEAIRPORT IS OF THE UPPER MOST IMPORTANCE. WHEN THERE IS CONFLICT BETWEEN OPERATION OF THE AIRPORT ANDCONSTRUCTION, OPERATION OF THE AIRPORT WITH HAVE PRIORITY.5.EXISTING GRADES SHOWN ON THE DRAWINGS ARE BELIEVED TO BE ACCURATE, BUT THE AIRPORT ASSUMES NORESPONSIBILITY FOR THE ACCURACY OF THESE GRADES. IF THE CONTRACTOR DOES NOT CONCUR WITH THEELEVATIONS GIVEN ON THE DRAWINGS, HE SHALL NOTIFY THE ENGINEER IN WRITING PRIOR TO INITIATING ANYCONSTRUCTION ACTIVITIES. START OF WORK BY THE CONTRACTOR WITHOUT SUCH NOTIFICATION WILL BEINTERPRETED AS AN AGREEMENT BY THE CONTRACTOR WITH THE ACCURACY OF THE GRADES SHOWN ON THE PLANS.6.NOT USED7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING AND ACQUIRING ALL REQUIRED COUNTY, STATE AND CITYPERMITS.8.THE CONTRACTOR SHALL REVIEW ALL AIRFIELD UTILITIES WITH AIRPORT MANAGEMENT PRIOR TO BEGINNING WORK.9.THE PROJECT PAY ITEM IS PROVIDED TO BE INCLUSIVE OF ALL WORK TO BE PERFORMED AS SHOWN IN THESE PLANS.ALL INCIDENTAL WORK REQUIRED TO COMPLETE THE PROJECT IS TO BE INCLUDED IN THE COSTS OF PERFORMINGTHESE ITEMS.10.TESTING - UNLESS OTHERWISE SPECIFIED, ALL QUALITY ASSURANCE (QA) TESTING REQUIRED BY THESPECIFICATIONS FOR ACCEPTANCE OF WORKMANSHIP AND/OR MATERIALS SHALL BE INITIATED AND PAID FOR BY THEOWNER. QUALITY CONTROL (QC) TESTING SHALL BE INITIATED AND PAID FOR BY THE CONTRACTOR. FAILED QATESTING SHALL REQUIRE RE-TESTING WHICH SHALL BE INITIATED BY THE ENGINEER AND PAID FOR BY THECONTRACTOR.MAINTENANCE OF TRAFFIC AND SAFETY1.THE CONTRACTOR IS ADVISED THAT ALL AIRPORT ROADWAYS, EXCEPT THOSE THAT ARE TO BE CONSTRUCTEDUNDER THIS CONTRACT, WILL BE ACTIVE DURING THIS CONTRACT. THE CONTRACTOR WILL BE EXPECTED TOCONDUCT THE WORK SUCH THAT THE SAFETY OF OPERATIONS IS NOT REDUCED AND THAT VEHICULAR FLOW ISMAINTAINED AT ALL TIMES, EXCEPT AS SPECIFICALLY PROVIDED FOR IN THE CONTRACT DOCUMENTS OR ALLOWED BYTHE OWNER IN WRITING. THE CONTRACTOR IS ADVISED, AND SHALL ACCEPT AS AN IMPORTANT CONSIDERATION OFTHE WORK, THAT THE MAINTENANCE OF SAFE AND EFFICIENT ACCESS TO THE AIRPORT VIA THE ROADWAY SYSTEM ISAN INTEGRAL PART OF THE WORK. IN CASES NOT SPECIFICALLY COVERED ELSEWHERE IN THE CONTRACTDOCUMENTS, ALL TRAFFIC MAINTENANCE SHALL BE ACCOMPLISHED IN CONFORMANCE TO THE LATEST EDITION OFTHE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD).DUST AND DEBRIS CONTROL1. THE CONTRACTOR SHALL PAY PARTICULAR ATTENTION TO THE DUST CONTROL REQUIREMENTS OF THIS CONTRACT.THE OPERATIONS OF THE RUNWAYS, TAXIWAYS, AND ASSOCIATED NAVAIDS ARE ESPECIALLY SENSITIVE TO DUST.THE CONTRACTOR SHALL BE PREPARED TO CONTROL DUST ON HAUL ROUTES ON A DAILY BASIS. WATERING, OROTHER APPROVED DUST CONTROL MEASURES SHALL BE AVAILABLE ON A DAILY BASIS TO CONTROL DUST. THEOWNER RESERVES THE RIGHT TO STOP GRADING AND HAULING, OR OTHER WORK IF NECESSARY, TO BRING DUSTUNDER CONTROL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DUST CONTROL WITHIN THE CONSTRUCTIONLIMITS AS WELL AS ALONG ANY ROADWAYS USED BY THE EQUIPMENT AND VEHICLES AT THE SOLE DISCRETION OFTHE AIRPORT.2.THE CONTRACTOR SHALL PROVIDE A FIBER BRISTLE PAVEMENT SWEEPER FOR KEEPING DEBRIS CLEAR AT ALLOPERATIONAL PAVEMENT CROSSING AREAS ON THE HAUL ROUTE AS REQUIRED BY AIRSIDE OPERATIONS.3.ALL UNSUITABLE MATERIAL AND CONSTRUCTION DEBRIS SHALL BE DISPOSED OF OFF OF AIRPORT PROPERTYUNLESS DIRECTED OTHERWISE BY THE ENGINEER OR AIRPORT PERSONNEL.4.SPECIFICATIONS ARE PROVIDED AS OUTLINE REQUIREMENTS FOR THE CONTRACTOR TO APPLY WATER, CHEMICALS,VEGETATION OR OTHER MATERIALS TO PREVENT THE OCCURRENCE OF DUST WHICH WILL BE OBJECTIONABLE TO THEOPERATIONS/USERS OF THE AREA. THESE SHALL INCLUDE, BUT ARE NOT LIMITED TO, AIRPORT OPERATIONS ANDMAINTENANCE AREAS; AIRCRAFT OPERATIONS AND AIRFIELD OPERATIONS. CONTRACTOR SHALL ALSO BE OBLIGATEDTO DISCONTINUE OPERATIONS WHICH VIOLATE EXISTING LAWS AND REGULATIONS OR CREATE AN UNDUE HAZARD TOAIR TRAFFIC. ALL COSTS FOR CONTROLLING DUST OR POLLUTANTS TO THE AIR OF ANY KIND SHALL BE INCIDENTAL TOTHE CONTRACT.ACCESS GATE REQUIREMENTS1.THE CONTRACTOR SHALL USE THE EXISTING GATE ENTRANCE (87ECHO / CHECKPOINT BRAVO), AND SHALL ADHERE TO ALL SECURITYREQUIREMENTS OF THE OWNER AS OUTLINED IN SECTION 4 "SAFETY AND SECURITY REQUIREMENTS" OF THE SPECIALPROVISIONS.2.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND MAINTAINING A SUITABLE ACCESS ROAD FROM THE PUBLICROADS TO THE SITE. UPON COMPLETION OF THE WORK, ANY ACCESS/HAUL ROUTE WILL BE DRESSED, HYDRO SEEDED ANDRESTORED TO THE ENGINEER'S SATISFACTION. NO SEPARATE PAYMENT SHALL BE MADE FOR THIS WORK, IT SHALL BEINCLUDED IN THE PROJECT.STORAGE, STAGING AND HAUL ROADS1.STORAGE AND STAGINGA)THE CONTRACTOR SHALL USE THE STORAGE AND STAGING AREA SPECIFIED FOR STOCKPILES,SHOPS, MAINTENANCE FACILITIES USE OF AND ALL CONTRACTOR SUPPORT FACILITIES. NOOTHER SITES SHALL BE PERMITTED ON AIRPORT PROPERTY WITHOUT WRITTEN APPROVALFROM THE ENGINEER AND OWNER.B)ALL COSTS ASSOCIATED WITH PREPARING THE STORAGE AND STAGING AREA SITE SHALL BEBORNE BY THE CONTRACTOR. THIS INCLUDES BUT IS NOT LIMITED TO, CLEARING AND GRADINGOF THE SITE, CONSTRUCTION OF ALL TEMPORARY UTILITIES, ACCESS ROADS, ALL SECURITYFENCING, ETC. AT THE CONCLUSION OF THE CONTRACT THE CONTRACTOR SHALL RESTORETHE SITE TO ITS PRE-CONSTRUCTION CONDITION.2.HAUL ROADSA)HAUL ROADS TO BE USED UNDER THIS PROJECT SHALL BE THOSE INDICATED ON THE DRAWINGSOR OTHERWISE SPECIFICALLY DESIGNATED BY THE OWNER/ENGINEER. IN GENERAL, THECONTRACTOR SHALL CONFINE EQUIPMENT AND HAULING TO THE AREAS UNDERCONSTRUCTION. NO DEBRIS SHALL BE ALLOWED ON THE ROADWAYS. THE PAVEMENT WILL BECLEANED BY THE CONTRACTOR USING POWER BROOMS OR SWEEPERS, AS REQUIRED, TO KEEPTHE AREA CLEAR OF ALL SOILS, CLODS OR OTHER DEBRIS. B)THE CONTRACTOR IS NOT PERMITTED TO OPERATE ANY CONSTRUCTION RELATED VEHICLES ONTHE AIRPORT ENTRANCE ROAD SYSTEM. ALL DELIVERIES TO THE STAGING AREA SHALL BE VIATHE HAUL ROUTES AS SHOWN ON THE PLANS.C)THE ACCESS POINTS TO THE PROJECT SITE SHALL BE DETERMINED BY SAA. THESPECIFIED GATE AREAS SHALL BE MONITORED DURING ALL CONTRACTOR OPERATIONS. IF IT ISDETERMINED BY THE OWNER/ENGINEER THAT THE CONTRACTOR'S HAULING OPERATIONS ARECAUSING EXCESSIVE DAMAGE TO THE EXISTING GATES OR PAVEMENT AREAS, THECONTRACTOR MAY BE REQUIRED TO CONSTRUCT, AT HIS EXPENSE, ADDITIONAL ACCESS GATESIMMEDIATELY ADJACENT TO THE EXISTING GATES. HE SHALL MAINTAIN THE NEW ACCESSPOINTS AND PROVIDE THE AFOREMENTIONED GATE GUARDS AT THESE LOCATIONS AND SHALLASSUME ALL LIABILITY FOR AIRPORT SECURITY RELATING TO THE USE OF THESE GATES.D)IF NECESSARY, THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR RESTORING ALL AIRPORTSERVICE ROADS, INCLUDING THE PERIMETER SERVICE ROAD, TO THEIR PRE-CONSTRUCTIONCONDITION WHERE SUCH ROADS ARE USED BY THE CONTRACTOR FOR HAULING OPERATIONS.THE CONTRACTOR AND THE ENGINEER SHALL JOINTLY DETERMINE THE EXISTING CONDITIONSAS A BASIS FOR THIS RESTORATION REQUIREMENT.E)THE CONTRACTOR SHALL RESTORE ALL TURFED AND PAVED AREAS USED FOR HAUL ROADS TOTHEIR ORIGINAL CONDITION, INCLUDING THE ESTABLISHMENT OF TURF. ALL HAULING ALONG ORCROSSING THE AIRPORT AND STATE ROADS SHALL BE ACCOMPLISHED IN ACCORDANCE WITHTHE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARDS AND SHALL BE COORDINATED BYAND ACCOMPLISHED BY THE CONTRACTOR. ALL COSTS FOR CONSTRUCTING, REMOVING ANDRESTORING OF HAUL ROADS REQUIRED FOR THE COMPLETION OF THE WORK SHALL BEINCLUDED IN THE APPROPRIATE ITEMS OF WORK CONTAINED IN THE PROPOSAL.3.OTHER CONTRACTORS AND AIRPORT EMPLOYEE PARKING AREASA)THE CONTRACTOR IS ADVISED THAT OTHER CONTRACTORS MAY BE WORKING ON THE AIRPORT,AND COOPERATION BETWEEN CONTRACTORS IS REQUIRED.STAGING AREAS - GENERAL REQUIREMENTS1.THE LOCATION AND SIZE OF THE CONTRACTOR'S STAGING AREA IS SHOWN FOR REFERENCE ONLY. THE ACTUALSIZE AND EXACT LOCATION WILL BE ESTABLISHED PRIOR TO CONSTRUCTION. THE FOLLOWING REQUIREMENTS WILLAPPLY, HOWEVER:A)ALL OF THE CONTRACTOR'S ACTIVITIES,WILL BE STAGED FROMTHIS AREA. THE CONTRACTOR WILL BE RESPONSIBLE FOR TRANSPORTING EMPLOYEES FROM THE STAGINGAREAS TO AND FROM THE WORK AREA.B)THE STAGING AREA IS, AND WILL REMAIN THROUGHOUT THE CONSTRUCTION, INSIDE THE AOA. IT WILL BENECESSARY, TO ERECT AIRPORT SECURITY BARRIER AROUND THE AREA. COST OF ANY FENCING AND OTHERWORK REQUIRED TO PREPARE THE STAGING AREA SHALL BE INCIDENTAL TO MOBILIZATION.C)IT IS NOT ANTICIPATED THAT THE AIRPORT'S OBSTRUCTION HEIGHT REQUIREMENTS, AS DEFINED BY THE FAR PART 77, WILL RESTRICT THE CONTRACTOR'S ACTIVITIES IN THE STAGING AREA. IT IS REQUIRED, HOWEVER, THAT THIS ASSUMPTION BE VERIFIED BY THE CONTRACTOR THROUGH THE OWNER PRIOR TO BEGINNING WORK.D)THE OWNER MAY, AT ITS DISCRETION, DESIGNATE THAT STAGING AREAS FOR OTHER CONTRACTORS BE LOCATED IN THE VICINITY. IF THIS OCCURS, THE CONTRACTOR SHALL COOPERATE, AS NECESSARY, TO ACCOMMODATE OTHERS..E)THE CONTRACTOR WILL BE REQUIRED TO OBSERVE ALL EXISTING TRAFFIC FLOW DIRECTIONS WHEN ENTERING AND LEAVING THE STAGING AREAS. NO COUNTER FLOW WILL BE ALLOWED ANY TIME.2.MATERIAL AND EQUIPMENT STORAGE SHALL BE LOCATED AS SHOWN ON THE SAFETY PLAN SHEET(S). THECONTRACTOR SHALL ADVISE ALL MATERIAL SUPPLIERS OF THE DELIVERY ROUTES TO BE USED FOR THE DELIVERYOF EQUIPMENT, MATERIALS, OR SUPPLIES. THE CONTRACTOR SHALL ALSO ADVISE THE SUPPLIERS THAT THERE WILLBE SET DELIVERY HOURS AND THEY WILL NOT BE ACCEPTED AT ANY OTHER TIME. DELIVERY HOURS WILL BE FROM8:00 AM TO 4:00 PM WEEKDAYS UNLESS PRIOR ARRANGEMENTS WITH AIRPORT PERSONNEL ARE MADE 48 HOURS INADVANCE. ANY DELIVERIES NOT MADE DURING THESE HOURS STATED WILL BE TURNED AWAY BY AIRPORTPERSONNEL. A REPRESENTATIVE OF THE CONTRACTOR MUST BE PRESENT FOR DELIVERY OF MATERIALS. MATERIALSAND EQUIPMENT NOT IN USE SHALL BE STORED OR PARKED IN AREAS DESIGNATED BY THE ENGINEER AND OUTSIDEOF THE RIGHT-OF-WAY AND TAXIWAY SAFETY ZONES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTRICTINGHIS/HER EQUIPMENT AND PERSONNEL TO THE IMMEDIATE VICINITY OF CONSTRUCTION AND TO AUTHORIZE AREASAND SHALL TAKE SUCH PRECAUTIONS, AT HIS OWN EXPENSE, AS ARE NECESSARY TO ASSURE COMPLIANCE WITHTHESE REQUIREMENTS.3.ALL MATERIALS AND EQUIPMENT, WHEN NOT IN USE, SHALL BE PLACED IN APPROVED AREAS WHERE THEY WILL NOTCONSTITUTE A HAZARD TO AIRPORT OPERATIONS. TALL BUTRELATIVELY LOW-VISIBILITY (I.E. CRANES, BACKHOES, DRILLS, ETC.) EQUIPMENT SHALL BESTORED IN A LOWERED CONFIGURATION WHEN NOT IN USE. THEAPPROVED STORAGE AREAFOR EQUIPMENT AND MATERIALS IS THE CONTRACTOR'S STAGING AREA. ANY OTHERAREAS TO BE USED FOR STORAGE MUST BE APPROVED BY THE ENGINEER AND OWNER PRIOR TO USE. EQUIPMENTAND/OR STOCKPILED MATERIALS SHALL BE STORED IN A MANNER TO PREVENT MOVEMENT RESULTING FROM WINDCONDITIONS.CONSTRUCTION PHASING REQUIREMENTS1.THE CONSTRUCTION PHASING AS SHOWN IN THESE CONTRACT DOCUMENTS IS A SIMPLIFIED PHASE DESCRIPTIONSHOWING GENERAL RELATIVE TIME FRAMES WITHIN WHICH CONSTRUCTION WORK WILL BE ACCOMPLISHED. THECONTRACTOR SHALL DEVELOP HIS OWN CONSTRUCTION SCHEDULE IN ACCORDANCE WITH THE REQUIREMENTS OFTHE SPECIFICATIONS AND DRAWINGS. THE CONTRACTOR SHALL SUBMIT THIS PLAN FOR REVIEW AND APPROVAL AMINIMUM OF 2 WEEKS PRIOR TO THE START OF CONSTRUCTION.SECURITY NOTES1.THE CONTRACTOR SHALL CONDUCT THEIR ACTIVITIES IN A SAFE AND SECURE MANNER AS SPECIFIED IN SECTION 4"SAFETY AND SECURITY REQUIREMENTS" OF THE SPECIAL PROVISIONS IN THE SPECIFICATIONS AND AS DESCRIBEDHEREIN.2.THE CONTRACTOR SHALL COMPLY WITH ALL SECURITY REQUIREMENTS SPECIFIED HEREIN, AND ALL FURTHERDIRECTIVES SPECIFIED BY THE OWNER OR DESIGNATED REPRESENTATIVE. CONTRACTOR SHALL FURTHER BEREQUIRED TO PAY ALL FINES LEVIED BY THE TRANSPORTATION SECURITY ADMINISTRATION OR OTHER AUTHORIZEDGOVERNMENTAL AUTHORITY FOR VIOLATIONS OF TSA RULES, REGULATIONS AND THE SANFORD AIRPORT AUTHORITY. FINES ARE ALSO ASSESSED BY S.A.A..3.CONTRACTOR PERSONNEL SECURITY ORIENTATION - THE CONTRACTOR SECURITY POINT OF CONTACT SHALL BERESPONSIBLE FOR BRIEFING ALL CONTRACTOR PERSONNEL ON THESE REQUIREMENTS AND, FROM TIME TO TIME,OTHER SECURITY PROVISIONS. ALL NEW CONTRACTOR EMPLOYEES SHALL BE BRIEFED ON THESE REQUIREMENTSPRIOR TO WORKING IN THE CONSTRUCTION AREA.4.ACCESS TO THE SITE - ALL CONSTRUCTION PERSONNEL MUST FOLLOW THE AIRPORT'S LATEST SECURITY ANDBADGING REQUIREMENTS. CONTRACTOR'S ACCESS TO THE SITE SHALL BE AS SHOWN ON THE PLANS OR ASDIRECTED BY THE ENGINEER. THE CONTRACTOR SHALL NOT PERMIT ANY UNAUTHORIZED CONSTRUCTIONPERSONNEL OR TRAFFIC ON THE SITE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TRAFFIC CONTROL TO ANDFROM THE VARIOUS CONSTRUCTION AREAS ON THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR THE IMMEDIATECLEANUP OF ANY DEBRIS DEPOSITED ALONG THE HAUL ROAD AS A RESULT OF CONSTRUCTION TRAFFIC.5.MATERIALS DELIVERY TO THE SITE - ALL CONTRACTOR'S MATERIAL ORDERS FOR DELIVERY TO THE SITE WILL USETHE ACCESS POINT AT THE CONTRACTOR'S STORAGE SITE.6.CONSTRUCTION AREA LIMITS - THE LIMITS OF CONSTRUCTION, MATERIAL STORAGE AREAS, EQUIPMENT STORAGEAREA, PARKING AREA AND OTHER AREAS DEFINED AS REQUIRED FOR THE CONTRACTOR'S EXCLUSIVE USE DURINGCONSTRUCTION SHALL BE MARKED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER AND OWNER. THECONTRACTOR SHALL ERECT AND MAINTAIN AROUND THE PERIMETER OF THESE AREAS SUITABLE FENCING, SIGNAGEAND WARNING DEVICES VISIBLE FOR BOTH DAY/NIGHT USE TO DELINEATE THE PERIMETER OF ALL SUCH AREAS.7. CONTRACTOR WILL BE REQUIRED TO ATTEND THE MONTHLY SECURITY MEETING HELD ON THE 4TH WEDNESDAY OF EACH MONTH.REVISIONS# DATE DESCRIPTION BYCONFORMED SET10
UNKGENERATORXXXXXXXXXXXXXXXXXXBENCHBENCHBENCHBENCHBENCHBENCHBENCHBOCEOPBOCEOPBOCEOP
BOCEOPSTA
OR
INGNDLANE
FIRE
NO PARKING BENCHBENCHEXISTING BAREXISTING RESTAURANTDRIV
E
Table
Table
TableTableTable
TableTableTableTableTable
shreddercopi er
pri
n
t
e
rhp 8550Table
Table
Table
Table
Table
Table
Table Table MECHANICALELECTRICALITFIRE PROTECTIONSYSTEMS LEGEND500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1" = 50'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:10:44 PMG108PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAEXISTING SYSTEMS CENTERS07-14-2017S12014 1" = 50'-0"1FIRST FLOOR - SYSTEM CENTERS 1" = 50'-0"2SECOND FLOOR - SYSTEM CENTERSNNORTHNNORTHREVISIONS# DATE DESCRIPTION BYCONFORMED SET11
UNKRESTRICTEDAREAKEEPOUTGENERATOR5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
BOS
BOS
BOS
BOS
BOS
BOS UPLOADING DOCK / BADGING AND POLICE STATION5825 S.F.LOADING DOCK920 S.F.CANOPY7280 S.F.CANOPY8560 S.F.CANOPY8380 S.F.FIRE PROTECTION20375 S.F.INBOUND BELTS AND INTERIOR REFRESH57420 S.F.NEW TERMINAL SKYWALK18,200 S.F.NEW TERMINAL / AND RESTROOMS 12800 S.F.NEW ELEVATOREXISTING PARKING DECKPHASESPHASE 1PHASE 2PHASE 3EXISTING WELCOME CENTERNEW ELEVATOR1070 S.F.BLOCKHOUSE ADDITION130 S.F.CANOPY1280 S.F.CHILLER YARD UPGRADEF.I.S. SECURITY EXIT1280 S.F.BAR RECONFIGURE, RESTROOM ADDITION AND BAGGAGE BELT ALTERATIONNEW PARKING LOT CANOPY AND TICKET STATIONNEW FLOORING AND WALL FINISHES500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/64" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:20:09 PMG109PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAAREA OF WORK / PHASING PLAN - 1ST FLOOR07-14-2017S12014 1/64" = 1'-0"1AREA OF WORK / PHASING PLAN - 1ST FLOORNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET12
Table
Table
Table
Table
Table
Table
Table FIRE PROTECTION9400 S.F.NEW TERMINAL SKYWALK18,200 S.F.NEW CANOPY2130 S.F.NEW SCREENING AREA EXISTING PARKING DECKPHASESPHASE 1PHASE 2PHASE 3NEW KID'S AREA / MOTERS ROOM AND RESTROOM REFRESHNEW BLADE SIGN WALLCANOPY6200 S.F.NEW ELEVATOR870 S.F.NEW CANOPYNEW CANOPY7200 S.F.NEW LOADING DOCK4400 S.F.EXISTING WELCOME CENTERNEW SECURITY EXITNEW TERMINAL EXPANSIONNEW ROOF REPLACEMENT14,000 S.F.NEW INTERIOR FINISH500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/64" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:17:50 PMG110PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAAREA OF WORK / PHASING PLAN - 2ND FLOOR07-14-2017S12014 1/64" = 1'-0"1AREA OF WORK / PHASING PLAN - 2ND FLOORNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET13
X24 in. min.610 mm.Y42 in.(min.)1065 mm.Y48 in. (min.)1220 mm.24 in. minimum.610 mm.DOOR WIDTHXYDOOR WIDTH4" Min.42 in. (min.)1065 mm.DOOR WIDTH54 in. (min.)1370 mm.60 in. (min.)1525 mm.4" (MIN.)48 in. (min.)1220 mm.18" Minimum.24" Preferred.DOOR WIDTHX4" Min.DOOR WIDTH42" MIN.12" MAX.33"-36"54" MIN.2'-3"4'-0"2'-3"4'-0"36" MAX.44" MAX.17"MAX.48" MAX. AFF TOOPERATING MECHANISM34" MAX.1'-3"29" MIN.34" MAX.27" MIN.17" MIN.3'-0" MIN6" MAX.12" MIN33"-36" -TOP OF BAR17" TO 19"1'-6"19"(15"MIN.)28" MAX.24" MAX.1-1/2"MIN.1-1/2"MIN.40" MAX. BOTTOM EDGEOF REFLECTIVE SURFACE3'-0"4'-0"3'-0"2'-0"5'-0"VARIES3"19"(15"MIN.)4'-0"MAX. TO PAPER4"MAX.RESTROOM FIXTURE & ACCESSORY ELEVATIONSMANEUVERING CLEARANCE AT DOORSMISC. ADA REQUIREMENTSNOTE: Y=54 in. (1370 mm.) If the door has a closer.NOTE: Y=48 in. (1220 mm.) If the door has a closer.NOTE: Y=48 in. (1220 mm) minimum if the door has both a closer and a latch.NOTE: X=12 in.(305 mm.) If the door has both a closer and a latch.LATCH-SIDE APPROACHES SWINGING- DOORSPULL SIDENOTE: X=36 in. (915 mm) If Y=60 in (1525 mm) X=42 in. (1065 mm) if Y=54 in.(1370 mm)HINGE-SIDE APPROACHES - SWINGING DOORSFRONT APPROACHES SWINGING - DOORSPUSH SIDEPULL SIDEPUSH SIDEURINALWATERCLOSETFLUSH CONTROL TOBE LOCATED ON THEWIDE SIDE OFHANDICAP STALLFIXTURETABLE TOPCHANGING TABLETOILET PAPER DISPENSERALL WALL-HUNGLAVS & URINALSSHALL UTILIZEMFR'S WALLCARRIAGES,ANCHORED TOSOLID FRAMING ORBLOCKINGSOLID BLOCKINGAROUND TOWELDISPENSERSOLID BLOCKING(CONCEALLED)INSULATE HOT, COLD AND DRAIN PIPE W/ "TRAPWRAP" KIT18" X 30" MIRRORW/ SAFETY EDGROR CHROMECHANNEL2 X 8 SOLID WOODBLOCKING (TYP AT GRABBARS)1 X 4 WOOD BLOCKING(TYP AROUND T.P. DISP)TOILET PAPERDISPENSERPROVIDECONCEALED SOLIDBLOCKINGBEHIND/AROUND ALLWASHROOMACCESSORIES1-1/2" DIA. GRAB BAROPTIONAL LOCATIONHANDICAP SIGNAGEMOUNTED WITHIN 8" OFJAMB ON STRIKE SIDEGENERAL NOTESSIGNAGE LEGENDRESTROOM SYMBOLSALL PERMANENT ROOM IDENTIFICATION SIGNS SHALL COMPLYWITH THE AMERICANS WITH DISABILITIES ACT.SIGNS SHALL BE ADHERED TO SUPPORTING SURFACE BY ADHESIVE,SELECTED FOR HIGH STRENGTH AND DURABILITY OF BOND BETWEENSIGN BACKING AND SUPPORTING SURFACE MATERIAL.SIGN BACKGROUND SHALL BE MINIMUM 1/8" THICK ACRYLIC PLATE.BACKGROUND COLOR SHALL BE SELECTED BY ARCHITECT FROMMANUFACTURER'S FULL RANGE OF STANDARD AND CUSTOM COLORS,AND SHALL PROVIDE AT LEAST 70% CONTRAST WITH WHITEFOREGROUND LETTERS. BACKGROUND FINISH SHALL BE NON-GLARE.ACRYLIC LETTERING SHALL BE RAISED AT LEAST 1/32", AND MAY BEACHIEVED THROUGH SURFACE APPLICATION, ETCHING OR INJECTIONMOLDING.ALL LETTERS SHALL BE UPPER CASE. LETTER SIZE SHALL BE ASINDICATED, BUT IN NO CASE LESS THAT 5/8" HIGH OR GREATER THAN 2"HIGH. TYPE STYLE SHALL BE HELVETICA MEDUIM, AND COLOR SHALL BENON-GLARE WHITE.WHERE MORE THAN ONE ROW OF LETTERING IS REQUIRED, THE LEADING(BLAND SPACE) BETWEEN ROWS SHALL BE APPROXIMATELY 80% OF THEHEIGHT OF THE LETTERING.GRADE 2 BRAILLE REQUIRED, COLOR TO BE SAME AS SIGN BACKGROUND.INTERNATIONAL PICTOGRAM SYMBOLS, WHERE REQUIRED, SHALL BERAISED AT LEAST 1/32" (SIMILAR TO LETTERS), AND SHALL HAVE AMINIMUM 6" HIGH VERTICAL FIELD. THE EQUIVALENT VERBALDESCRIPTION (TEXT) OF THE PICTOGRAM SHALL BE PLACED DIRECTLYBELOW THE PICTOGRAM, AND SHALL BE ACCOMPANIED BY GRADE 2BRAILLE.PICTOGRAMS SHALL BE REQUIRED FOR THE FOLLOWING ROOM SIGNS:MEN (MALE ACCESSIBLE RESTROOM) WOMEN (FEMALE ACCESSIBLERESTROOM)VARIES1"1"6" MIN. 1"5/8" MIN.1"1/2" RIN ACCORDANCE WITH ADA REQUIREMENTS, ALL PERMANENTROOM IDENTIFICATION SIGNS SHALL BE INSTALLED ON THE WALLADJACENT TO THE LATCH SIDE OF THE DOOR, AND SHALL BEMOUNTED WITH THE CENTERLINE OF THE SIGN AT 5'-0" A.F.F.MOUNTING LOCATION FOR SIGN SHALL BE SUCH THAT A PERSONMAY APPROACH WITHIN 3" OF THE SIGN WITHOUTENCOUNTERING PROTRUDING OBJECTS OR STANDING IN THESWING OF THE DOOR. IF THERE IS INSUFFICIENT WALL SPACEADJACENT TO THE LATCH SIDE OF THE DOOR, THE SIGN SHALL BEMOUNTED ON THE NEAREST ADJACENT WALL. ADA SIGNAGESHALL COMPLY WITH THE DETAILS PROVIDED AT THE RIGHT.DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICESSHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOESNOT REQUIRE TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE.HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTEDAT 36" (in.) ABOVE FINISH FLOOR.DOOR CLOSERS SWEEP PERIOD SHALL BEADJUSTED SO THAT FROM AN OPENPOSITION OF 70°, THE DOOR WILL TAKE ATLEAST 3 SECONDS TO MOVE TO A POINT 3 IN.FROM THE LATCH, MEASURED TO THELEADING EDGE OF THE DOOR. ADJUST FOR5 LB. MAX FORCE.OPTIONAL ADA SIGNLOCATIONTYPICAL ELECTRICALSWITCH,DIMMER, ETC.LEVER HARDWARE (TYP.)THERMOSTATCL.1. REQUIRED ACCESSIBLE ELEMENTS SHALL BE IDENTIFIED BY THEINTERNATIONAL SYMBOL OF ACCESSIBILITY AT THE FOLLOWING LOCATIONS -ACCESSIBLE ENTRANCES WHERE NOT ALL ENTRANCES ARE ACCESSIBLE. -ACCESSIBLE ROOMS WHERE MULTIPLE SINGLE-USER TOILETS ARE CLUSTERED AT A SINGLE LOCATION. -ACCESSIBLE CHECK-OUT AISLES WHERE NOT ALL AISLES ARE ACCESSIBLE. THE SIGN, WHERE PROVIDED, SHALL BE ABOVE THE CHECK-OUT AISLE IN THE SAME LOCATION AS THE CHECK-OUT AISLE NUMBER OR TYPE OF CHECK-OUT IDENTIFICATION. -UNISEX TOILET AND BATHING ROOMS. -ACCESSIBLE DRESSING, FITTING AND LOCKER ROOMS WHERE NOT ALL SUCH ROOMS ARE ACCESSIBLE.2. DIRECTIONAL SIGNAGE INDICATING THE ROUTE TO THE NEAREST LIKEACCESSIBLE ELEMENT SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS.THESE DIRECTIONAL SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL OFACCESSIBILITY. -AT EACH SEPARATE-SEX TOILET INDICATING THE LOCATION OF THENEAREST UNISEX TOILET.3. TACTILE SIGNAGE SHALL BE LOCATED ON THE WALL TO THE DOOR'S LATCHSIDE AT A HEIGHT OF 60" AFF TO THE BASELINE OF THE HIGHEST TACTILECHARACTER. SIGNS MAY BE PLACED ON THE NEAREST ADJACENT WALLWHEN THERE IS NO WALL SPACE ON THE LATCH SIDE.4. CHARACTER AND SYMBOLS OF SIGNS SHALL BE IN CONTRAST WITH THEIRBACKGROUND AND SHALL BE EGGSHELL, MATTE, OR OTHER NON-GLAREMATERIALS OR FINISHES.5. ACCESSIBLE SIGNAGE SHALL USE GRADE II BRAILLE AND MUST COMPLYWITH ANSI A117.1 SECTION 703.4.LIQUIDSOAPDISPENSERFIREEXTINGUISHERBRACKETMOUNTEDFIREEXTINGUISHERCABINETSANITARYNAPKINRECEPTACLE(OPT.)TOWELDISPENSER& WASTERECEPTACLE(OPT.)WASTERECEPTACLE(OPT.)TOWELDISPENSER(OPT.)ELECTRICHANDDRYERTOILET ROOM FIXTURES AND ACCESSORIES SHALL BE CERTIFIED BYMANUFACTURER FOR COMPLIANCE WITH AMERICANS WITH DISABILITIES ACT.ALL FIXTURES SHALL BE MOUNTED AT HEIGHTS AND WITH CLEARANCES ASREQUIRED BY ADA, AND AS FOLLOWS:CENTER OF TOILETS SHALL BE MOUNTED EXACTLY 18" FROM SIDE WALL ORPARTITION, AND TOP OF SEAT SHALL BE FROM 17" TO 19" AFF. FLUSHCONTROL SHALL BE LOCATED NOT MORE THAN 28" AFF, AND SHALL BEOPERABLE WITH MAX. 5 LB. FORCE.GRAB BARS SHALL BE PROVIDED AT EACH TOILET, MOUNTED W/ TOP FROM33" TO 36" AFF. MOUNT GRAB BARS INTO CONCEALED, SOLID WOODBLOCKING AS REQUIRED TO RESIST 250 PLF FORCE APPLIED TO GRAB BARAT ANY POINT IN ANY DIRECTION GRAB BARS SHALL BE FROM 1-1/4" TO 1-1/2"IN DIAMETER AND SHALL PROTECT AT LEAST 1-1/2" FROM WALL PROVIDECONCEALED FASTNERS WITH TRIM SCUTCHEON . TOILET PAPER DISPENSERSSHALL BE INSTALLED BELOW GRAB BAR ON SIDE WALL AT LEAST 15" AFF ANDA MAXIMUN OF 36" AWAY FROM REAR WALL. PROVIDE CONCEALLED SOLIDBLOCKING. PAPER TOWEL DISPENSERS SHALL BE MOUNTED ON WALL BESIDEEACH LAV, WITH DISPENSER SLOT NOT MORE THAN 44" AFF. PROVIDE SOLIDWOOD BLOCKING IN WALL AROUND ROUGH OPENING. WALL HUNG LAV SHALLBE MOUNTED WITH FRONT ROOM AT 2'-10" AFF MAX.MIRRORS SHALL HAVE POLISHED SAFETY EDGE OR CHROME CHANNEL EDGE,AND SHALL BE MOUNTED ABOVE EACH LAV. W/BOTTOM AT 40" AFF. MIRRORSSHALL BE MIN. 18" WIDE X 30" HEIGHT.FINISHEDFLOORGENERAL BLOCKING NOTE: ALL CONCEALLEDWALL BLOCKING SHALL BE MIN. 22 GA. GALV.STEEL, OR FIRE RETARDANT TREATED WOOD(EXCEPT THAT STANDARD WOOD MAY BE USEDONLY IN RESTROOMS WITH UNTREATED WOODFRAME WALLS)TPULL SIDEPUSH SIDEALL SIGNAGE IS SUPPLIED AND INSTALLED BY GENERAL CONTRACTORAUTOMATIC OR BLADE STYLE FAUCETTOP OFLAVATORYREFLECTIVEPART OFMIRRORBOTTOMCLEARFLOORSPACE3'-0"9"2'-10"2'-3"3'-4"MAX.MAX.MIN.MIN.MIN.17" TO 25"KNEE/TOE CLEARANCE1'-10"MIN.1'-4"4'-0"MAX.2'-6"MIN.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:12:45 PMG111PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAADA SPECIFICATIONS07-14-2017S12014 1/2" = 1'-0"2HANDICAP CLEARANCESREVISIONS# DATE DESCRIPTION BYCONFORMED SET14
UNKRESTRICTEDAREAKEEPOUT GENERATOR5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
BOS
BOS
BOS
BOS
BOS
BOS
REF.UPUPBUILDING ADDITIONCANOPYCANOPYOPENCANOPYPARKING GARAGEBMALOADING DOCKOPENEXISTING (4) HOUR WALLEXISTING (4) HOUR WALLSKYWAY ABOVESKYWAY ABOVE1ST FLOOR EXISTING = 72,370 S.F.1ST FLOOR EXISTINGINTERNATIONAL BAGGAGE CLAIM / OFFICES = 32,800 S.F.1ST FLOOR EXISTINGDOMESTIC BAGGAGE CLAIM 3 = 13,000 S.F.1ST FLOOR EXISTINGDOMESTIC BAGGAGE CLAIM 1,2, TICKETING AND OFFICES = 88,080 S.F.NEW (4) HOUR WALLMAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT (1004.1.2)LEGENDAIRPORT TERMINAL / CONCOURSE 100 GROSSAIRPORT TERMINAL / WAITING AREAS 15 GROSSAIRPORT TERMINAL / MERCANTILE 30 GROSSAIRPORT TERMINAL / BUSINESS 100 GROSSAIRPORT TERMINAL / STANDING 5 GROSSAIRPORT TERMINAL / BAGGAGE CLAIM 20 GROSSINDUSTRIAL / STORAGE - STOCK 300 GROSSUNDER CANOPYTOTAL EXIT WIDTH REQUIRED (1005.1) TOTAL OCCUPANT LOAD x 0.2 INCHES PER PERSON = INCHES REQUIRED9813 PEOPLE x 0.2 INCHES PER PERSON = 1962.6 INCHES REQUIREDEXIT WIDTH PROVIDED18 - 36" EXIT DOORS:648 INCHES CLEAR WIDTH 28 - 72" EXIT DOORS2016 INCHES CLEAR WIDTHTOTAL PROVIDED2664 INCHES CLEAR WIDTH PROVIDED OCCUPANCY CALCULATIONS - 1ST FLOORSPACE / USE OCCUPANCY AREA OCCUPANT PER S.F. OCCUPANT LOAD TICKETING AREASA-319,515 S.F.1/151301CONCOURSEA-36289 S.F.1/10063MERCANTILEM2274 S.F.1/3076ASSEMBLY / STANDINGA-318,489 S.F.1/53698BUSNIESSB68,105 S.F.1/100682BAGGAGE CLAIMA-377,680 S.F1/203884STORAGE / STOCKI32,484 S.F.1/300109 TOTAL 224,836 S.F.TOTAL OCCUPANTS 9813 PEOPLETHIS PROJECT IS A LEVEL 3 ALTERATION AND WILL NOT CHANGE OCCUPANCY (A-3). REFER TO APPROPRIATE SECTIONS OF THE EXISTING BUILDING CODEFIRE PROTECTION SERVICES (FBC 906.3(1)FIRE ALARM SYSTEM AND PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AT A MAXIMUM TRAVEL DISTANCE OF 75'. MAXIMUM FLOOR AREA FOR EACH EXTINGUISHER IS 11,250 sf MEANS OF EGRESS (FBC 1004.1.2)MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANTBAGGAGE CLAIM20 SF PER OCCUPANTBAGGAGE HANDLING300 SF GROSS PER OCCUPANTCONCOURSE100 SF GROSS PER OCCUPANTWAITING AREAS 15 SF GROSS PER OCCUPANTMERCANTILE30 SF GROSS PER OCCUPANTBUSINESS100 SF GROSS PER OCCUPANTSTORAGE / STOCK300 SF GROSS PER OCCUPANTMAXIMUM EXIT ACCESS TRAVEL DISTANCE (1016.2)A-OCCUPANCY (SPRINKLED)250 FEETRE: SHEET GS101 FOR ADDITIONAL INFORMATIONCODE INFORMATION - 1ST FLOOR500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:14:01 PMG112PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE PLAN - LIFE SAFETY - FIRST FLOOR07-14-2017S12014 1/64" = 1'-0"1LIFE SAFETY PLAN - FIRST FLOORNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET15
Table
Table
Table
Table
Table
Table
Table 29'-8"29'-1"28'-5"2'5'-10"12'-4"11'-2"12'-4"11'-10"12'-4"12'-5"12'-4"5'-3"10'1'-6"10'-10"3'-8"2'-7"2'4'-1"4'-8"5'-7"4'3'-5"8'-8"8'-1"7'-6"1'-6"1'-6"6"12'-9"5'3'1'-6"6'10'-3"9'-7"TDC #8TDC #7TDC #6TDC #5TDC #4TDC #3TDC #2TDC #1BINSEMPTY
BINSEMPTYBINSEMPTYBINSEMPTY
BINSEMPTY
BINSEMPTYAT26040 aTiX60" DIVES T TA BLE 60" DIVEST TABLE
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVES T TA BLE60" DIVEST TABLERoof
Minimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONT
L3
ENT
ER
EXIT
BINSEMPTY
BINSEMPTYBINSEMPTYBINSEMPTY
BINSEMPTY
BINSEMPTYAT26040 aTiX60" DIVES T TA BLE 60" DIVEST TABLE
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVES T TA BLE60" DIVEST TABLERoof
Minimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONT
L3
ENT
E
R
EXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVES T TA BLE 60" DIVEST TABLE
BINSEMPTY
BINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX 60" DIVES T TA BLE 60" DIVEST TABLE
Roof
Minimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or aboveFRONT
L3ENT
E
REXIT
BINSEMPTY
BINSEMPTYBINSEMPTYBINSEMPTY
BINSEMPTY
BINSEMPTYAT26040 aTiX60" DIVES T TA BLE 60" DIVEST TABLE
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVES T TA BLE60" DIVEST TABLERoof
Minimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONT
L3
ENT
ER
EXIT
TDC/CAT
TDC/CAT
TDC/CAT
TDC/CAT
TDC/CAT
TDC/CAT
TDC/CAT
TDC/CA
TAVSAVS
FR
O
N
T
ETDBLS
AVSAVS
FR
O
N
TETDBLS
FR
O
N
TETDBLSAVS
FR
O
N
TETDBLS
AVS
AVSAVS
FR
O
N
T
ETDBLS
23'-9"3'LADA GA TE WTMD
CEIA
12ETDETDETDETD
LL
4
3
L4
3
L
3
L
3
2
3'-9"3'LADA GA TE WTMD
CEIA
1
23'-9"3'LADA GA TE WTMD
CEIA
1
23'-9"3'LADA GA TE WTMD
CEIA
1 UPUPSKYWAY ADDITIONNEW CANOPYNEW STAIR #1NEW STAIR #2EXISTING ROOFEXISTING ROOFEXISTING ROOFEXISTING ROOFRELOCATED STAIR #1EXISTING STAIREXISTING STAIREXISTING STAIREXISTING STAIRCANOPYCANOPYTERMINAL B EXPANSIONLOADING DOCKEXISTING STAIRNEW STAIRNEW ROOFEXISTING STAIR (2) 4'-0" DOORS 480 PEOPLEEXISTING (4) HOUR WALLEXISTING (4) HOUR WALLEXISTING STAIRSKYWAY ADDITION = 18,200 S.F.EXISTING 2ND FLOOR = 98,300 S.F.EXISTING 2ND FLOOR OFFICE = 9,100 S.F.EXISTING 2ND FLOOR TERMINAL B AND SCREENING AREAS = 103,640 S.F.CANOPYEXISTING STAIR (2) 4'-0" DOORS 480 PEOPLEEXISTING STAIR (2) 4'-0" DOORS 480 PEOPLEEXISTING STAIR (2) 4'-0" DOORS 480 PEOPLEEXISTING STAIR (2) 4'-0" DOORS 480 PEOPLE(2) 3'-0" DOORS360 PEOPLE(2) 3'-0" DOORS360 PEOPLE(4) 3'-0" DOORS720 PEOPLE(2) 4'-0" DOORS480 PEOPLE(2) 4'-0" DOORS480 PEOPLE(2) 3'-0" DOORS360 PEOPLE(2) 3'-0" DOORS360 PEOPLE4'-0" DOOR240 PEOPLE(2) 4'-0" DOORS480 PEOPLEEXISTING PARKING GARAGEEXISTING WELCOME CENTERNEW (4) HOUR WALL UL U907EXISTING (2) HOUR WALLMAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT (1004.1.2)LEGENDAIRPORT TERMINAL / CONCOURSE 100 GROSSAIRPORT TERMINAL / WAITING AREAS 15 GROSSAIRPORT TERMINAL / MERCANTILE 30 GROSSAIRPORT TERMINAL / BUSINESS 100 GROSSAIRPORT TERMINAL / STANDING 5 GROSSLIFE SAFETY LEGENDFEWALL MOUNTED FIRE EXTINGUISHER / 10LB TYPE ABCEMERGENCY LIGHT (EM)EXIT SIGNSTOTAL EXIT WIDTH REQUIRED (1005.1) TOTAL OCCUPANT LOAD x 0.2 INCHES PER PERSON = INCHES REQUIRED7584 PEOPLE x 0.2 INCHES PER PERSON = 1516.8 INCHES REQUIREDEXIT WIDTH PROVIDED4 - 36" EXIT DOORS:144 INCHES CLEAR WIDTH20 - 72" EXIT DOORS:1440 INCHES CLEAR WIDTH TOTAL PROVIDED1584 INCHES CLEAR WIDTH PROVIDED OCCUPANCY CALCULATIONS - 2ND FLOORSPACE / USE OCCUPANCY AREA OCCUPANT PER S.F. OCCUPANT LOAD WAITING AREASA-339,500 S.F.1/152634CONCOURSEA-3114,895 S.F.1/1001149MERCANTILEA-315,300 S.F.1/30511ASSEMBLY / STANDINGA-316,000 S.F.1/53200BUSNIESSA-38,950 S.F.1/10090 TOTAL 194,645 S.F.TOTAL OCCUPANTS 7584 PEOPLETHIS PROJECT IS A LEVEL 3 ALTERATION AND WILL NOT CHANGE OCCUPANCY (A-3). REFER TO APPROPRIATE SECTIONS OF THE EXISTING BUILDING CODEFIRE PROTECTION SERVICES (FBC 906.3(1)FIRE ALARM SYSTEM AND PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AT A MAXIMUM TRAVEL DISTANCE OF 75'. MAXIMUM FLOOR AREA FOR EACH EXTINGUISHER IS 11,250 sf MEANS OF EGRESS (FBC 1004.1.2)MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANTBAGGAGE CLAIM20 SF PER OCCUPANTBAGGAGE HANDLING300 SF GROSS PER OCCUPANTCONCOURSE100 SF GROSS PER OCCUPANTWAITING AREAS 15 SF GROSS PER OCCUPANTMERCANTILE30 SF GROSS PER OCCUPANTMAXIMUM EXIT ACCESS TRAVEL DISTANCE (1016.2)A-OCCUPANCY (SPRINKLED)250 FEETRE: SHEET GS101 SHEET FOR ADDITIONAL INFORMATIONCODE INFORMATION - 2ND FLOOR500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:14:35 PMG113PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE PLAN - LIFE SAFETY - SECOND FLOOR07-14-2017S12014 1/64" = 1'-0"1LIFE SAFETY PLAN - SECOND FLOORNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET16
1CORE - 8" CMU VERTICALLY REINFORCED -CELLS FILLED WITH FOAM INSULATIONEXTERIORINTERIOR5/8" (3) COAT SMOOTH FINISH STUCCO -PAINTED4"CONTINUOUS SCREED GUARD1 1/2" METAL FURRING STRIPS AT 24" O.C.5/8" GWB - PAINTED1 1/2" RIGID INSULATION1A UL 914CORE - 8" CMU VERTICALLY REINFORCEDINTERIOR FINISH - 5/8" GWB OVER 1 /2" FURRING CHANNELS - PAINTEDFIRE RATING - 2 HR UL 914INTERIORINTERIOR1 1/2" METAL FURRING STRIPS AT 24" O.C.5/8" GWB -PAINTED1 /2" RIGID INSULATIONINTERIOR FINISH - 5/8" GWB OVER 1 /2" FURRING CHANNELS WITH RIGID INSULATION - PAINTED1 1/2" METAL FURRING STRIPS AT 24" O.C.5/8" GWB -PAINTEDNOTE" IN LOADING DOCK AREA ONLY - USE FIRE TREATED PLYWOOD IN LIEU ON GWB UP TO 48" A.F.F.1BCORE - 12" CMU VERTICALLY REINFORCED - CELLS FILLED WITH FOAM INSULATIONEXTERIOR FINISH - 5/8" (3) COAT SMOOTH FINISH STUCCO - PAINTEDFIRE RATING - O HREXTERIOR5/8" (3) COAT SMOOTH FINISH STUCCO -PAINTED4"CONTINUOUS SCREED GUARD2CORE - 6" METAL STUDINTERIOR FINISH - 5/8" GWB - PAINTEDFIRE RATING - O HR3 1/2" FIBERGLASS INSULATIONINTERIOR FINISH - 5/8" GWB - PAINTED3 1/2" FIBERGLASS INSULATIONNOTE" IN WET AREAS AND UNDER TILE CLADDING USE MOISTURE RESISTANT GWB5/8" GWB - PAINTED5/8" GWB -PAINTEDREFER TO FINISH SCHEDULE FOR BASE6"METAL STUDS @ 24" O.C.CONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARY2ACORE - 6" METAL STUDINTERIOR FINISH - 5/8" GWB - PAINTEDFIRE RATING - O HRINTERIOR FINISH - 5/8" GWB - PAINTEDNOTE" IN WET AREAS AND UNDER TILE CLADDING USE MOISTURE RESISTANT GWB5/8" GWB - PAINTED5/8" GWB - PAINTEDREFER TO FINISH SCHEDULE FOR BASE6"METAL STUDSCONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARY2BCORE - 6" METAL STUD EXTERIOR FINISH - METAL PANEL SYSTEM OVER 7/8" METAL HAT CHANNEL, OVER TYVEK MOISTURE BARRIER AND 5/8" DENS-GLASS GOLD SHEATHING -METAL SIDING TO MATCH ADJACENT COLOR AND FINISHFIRE RATING - O HR3" FIBERGLASS BATT INSULATION INTERIOR FINISH - 5/8" GWB - PAINTED3 1/2" FIBERGLASS INSULATION5/8" GWB - PAINTED5/8" DENSGLASS GOLD SHEATHINGPREFINISHED METAL SILL TRIM6" METAL STUDSCONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARYEXTERIORINTERIOR1CCORE - 8" CMU VERTICALLY REINFORCED - CELLS FILLED WITH FOAM INSULATIONEXTERIOR FINISH - 5/8" (3) COAT SMOOTH FINISH STUCCO - PAINTEDFIRE RATING - O HREXTERIOR4"CONTINUOUS SCREED GUARD2CCORE - 6" METAL STUDFIRE RATING - O HR3 1/2" FIBERGLASS BATT INSULATIONINTERIOR FINISH - 5/8" GWB - PAINTED3 1/2" FIBERGLASS INSULATION5/8" GWB - PAINTED7/8" (3) COAT SMOOTH FINISH STUCCO -PAINTEDREFER TO FINISH SCHEDULE FOR BASE6"METAL STUDSCONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARYEXTERIORINTERIOREXTERIOR FINISH - 7/8" (3) COAT SMOOTH FINISH STUCCO - PAINTEDEXTERIOR FINISH - 5/8" (3) COAT SMOOTH FINISH STUCCO - PAINTEDINTERIOR FINISH - 5/8" GWB OVER 1 /2" FURRING CHANNELS WITH RIGID INSULATION -PAINTEDFIRE RATING - O HRINSULATION VALUE R-18NOTE" IN LOADING DOCK AREA ONLY - USE PLYWOOD IN LIEU ON GWB UP TO 48" A.F.F.CORE-FILL 500 FOAM INSULATIONMETAL PANEL SIDING ATTACHED TO HORIZONTAL METAL HAT-CHANNEL @ 24" O.C. 5/8" DENSGLASS GOLD SHEATHING3CORE - 3 5/8" METAL STUDINTERIOR FINISH - 5/8" GWB - PAINTEDFIRE RATING - O HRINTERIOR FINISH - 5/8" GWB - PAINTED3 1/2" FIBERGLASS INSULATIONNOTE" IN WET AREAS AND UNDER TILE CLADDING USE MOISTURE RESISTANT GWB5/8" GWB - PAINTED5/8" GWB - PAINTEDREFER TO FINISH SCHEDULE FOR BASE3 5/8"METAL STUDS @ 24" O.C.CONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARY3 1/2" FIBERGLASS BATT INSULATION2DCORE - 8" METAL STUDFIRE RATING - O HR3 1/2" FIBERGLASS BATT INSULATIONINTERIOR FINISH - 5/8" GWB - PAINTED3 1/2" FIBERGLASS INSULATION5/8" GWB - PAINTEDREFER TO FINISH SCHEDULE FOR BASE8" METAL STUDSCONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARYEXTERIORINTERIOREXTERIOR FINISH - 7/8" (3) COAT SMOOTH FINISH STUCCO - PAINTED1EUL U906CORE - 8" CMU VERTICALLY REINFORCEDFIRE RATING - 2 HR UL U9065/8" (3) COAT SMOOTH FINISH STUCCO -PAINTEDINTERIORCORE-FILL 500 FOAM INSULATIONCORE-FILL 500 FOAM INSULATIONINTERIORCONTINUOUS MEMBRANE LAYERFELT BACKED SELF FURRING METAL LATHCONTINUOUS MEMBRANE LAYER7/8" (3) COAT SMOOTH FINISH STUCCO -PAINTED5/8" DENSGLASS GOLD SHEATHINGFELT BACKED SELF FURRING METAL LATHCONTINUOUS MEMBRANE LAYERNOTE: SEAL ALL PENETRATIONS IN WALL WITH APPROVED UL DETAILNOTE: SEAL ALL PENETRATIONS IN WALL WITH APPROVED UL DETAILGAUGE - 20 / NON LOAD BEARINGGAUGE - 18 / NON LOAD BEARINGGAUGE - 18 / NON LOAD BEARINGGAUGE - 18 / NON LOAD BEARINGGAUGE - 20 / NON LOAD BEARINGGAUGE - 20 / NON LOAD BEARINGNOTE: FOR ALL METAL STUD WALLS REFER TO MANUFACTURES LIMITING HEIGHT CHARTS AND CALCULATIONS BEFORE SELECTING GAUGE AND SPACING1DCORE - 8" CMU VERTICALLY REINFORCEDINTERIOR FINISH - 1 1/2" FURRING STRIPSINTERIOR FINISH - PAINTPAINT1 1/2" FURRING STRIPS @ 24" O.C.5/8" GYPSUM WALL BOARD - PAINTED500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1 1/2" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/26/2017 3:46:35 PMG114PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL TYPES07-14-2017S12014NOTE: REFER TO REFLECTED CEILING PLANS FOR WALLS THAT NEED TO EXTEND TO DECK / ROOFREVISIONS# DATEDESCRIPTIONBY5 09-22-2017 ADDENDUM 55CONFORMED SET17
6CORE - PREMANUFACTURED COOLER WALL PANEL4" COOLER WALL PANEL - EMBOSSED ALUMINUM FINISH (BOTH SIDES)7CORE - 3 5/8" METAL STUDEXTERIOR FINISH - 7/8" THICK (3) COAT SMOOTH FINISH STUCCO - PAINTED OVER METAL LATH WITH FELT BACK PAPER OVER TYVEK MEMBRANE OVER 5/8" EXTERIOR GRADE SHEATHING - BOTH SIDESFIRE RATING - O HR5/8" EXTERIOR GRADE SHEATHING3 5/8"METAL STUDS @ 24" O.C.CONTINUOUS METAL TRACK7/8" (3) COAT SMOOTH FINISH THICK STUCCO -PAINTED3BCORE - 3 5/8" METAL STUDFIRE RATING - O HRINTERIOR FINISH - 5/8" GWB - PAINTED5/8" GWB - PAINTEDCHASE OR PLENUM SIDEREFER TO FINISH SCHEDULE FOR BASE3 5/8"METAL STUDS @ 24" O.C.CONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARY3C UL 415CORE - 4" C-H METAL STUDINTERIOR FINISH - (2) LAYERS 5/8" GWB TYPE "X"-PAINTEDFIRE RATING - 2 HR UL 415NOTE: SEAL ALL PENETRATIONS IN WALL WITH APPROVED UL DETAIL(2) LAYERS 5/8" GWB -PAINTEDREFER TO FINISH SCHEDULE FOR BASE4" C-H METAL STUDS @ 24" O.C. VERTICALCONTINUOUS METAL TRACKINTERIOR FINISH - (1) LAYER OF 1" GWB TYPE "X"(1) LAYER OF 1" GWB LINER SHAFT WALL PANELS - 24" WIDE (2) LAYERS 5/8" GWB -PAINTEDPLAN VIEW3ACORE - 3 5/8" METAL STUDINTERIOR FINISH - 5/8" GWB - PAINTEDFIRE RATING - O HRINTERIOR FINISH - 5/8" GWB - PAINTEDNOTE - IN WET AREAS AND UNDER TILE CLADDING USE MOISTURE RESISTANT GWB TO CEILING . IN ELECTRICAL ROOMS USE 5/8" PLYWOOD IN LIEU OF GWB TO FLOOR CEILING -PAINTED5/8" GWB - PAINTED5/8" GWB - PAINTEDREFER TO FINISH SCHEDULE FOR BASE3 5/8"METAL STUDS @ 24" O.C.CONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARY4CORE - PREMANUFACTURED METAL BUILDINGALUMINUM METAL PANELSEXTERIOR FINISH - METAL PANELS - MATCH ADJACENT EXISTING PANELSINTERIOR FINISH - 5/8" GWB OVER PURLINS3" FACED BATT INSULATION R-20METAL GIRTS BETWEEN STEEL COLUMNS5/8" GWB ATTACHED TO PURLINS -PAINTED3DCORE - 3 5/8" METAL STUDINTERIOR FINISH - 5/8" GWB - PAINTEDFIRE RATING - O HRINTERIOR FINISH - 5/8" GWB - PAINTED3 1/2" BATT INSULATIONNOTE" IN WET AREAS AND UNDER TILE CLADDING USE MOISTURE RESISTANT GWB5/8" GWB - PAINTED5/8" GWB - PAINTEDREFER TO FINISH SCHEDULE FOR BASE3 5/8"METAL STUDS @ 24" O.C.CONTINUOUS METAL TRACKPROVIDE BLOCKING FOR WALL MOUNTED ITEMS AS NECESSARY3 1/2" FIBERGLASS BATT INSULATION7/8" HAT CHANNEL ATTACHED TO "QUIET CLIP" . ATTACH CLIP TO STUD @ 48" O.C. VERTICAL4" TO 6"2' - 0"QUIET CLIP7/8" HAT CHANNEL8CORE - 3 5/8" 18 GAUGE METAL STUD @ 16" O.C.INTERIOR FINISH - 5/8" GWB - PAINTEDINTERIOR FINISH - 3/4" PLYWOOD - UNFINISHED -FULL HEIGHTFIRE RATING - O HR3 5/8"METAL STUDS @ 24" O.C.BONDED WAREHOUSE SIDE3/4" PLYWOOD - FULL HEIGHT(1) LAYER 5/8" GWB -PAINTEDREFER TO FINISH SCHEDULE FOR BASE10 UL 907CORE - 12" CMU REINFORCED - REFER TO STRUCTURALFIRE RATING - 4 HR UL 907INTERIOR FINISH - 5/8" GWB OVER 1 /2" FURRING CHANNELS WITH RIGID INSULATION - PAINTEDEXTERIOR FINISH - 5/8" (3) COAT SMOOTH FINISH STUCCO - PAINTED EXTERIOR5 /8" THICK (3) COAT SMOOTH FINISH STUCCO - PAINTEDINTERIOR1 1/2" METAL FURRING STRIPS AT 24" O.C.5/8" GWB - PAINTED1 1 /2" RIGID INSULATION12" REINFORCED CMU5CORE - INTERIOR STOREFRONT SYSTEM -CENTER MOUNTED TEMPERED GLAZING - KAWNEER TRI FAB 451 OR ARCHITECT APPROVED EQUAL1/4" TEMPERED GLAZINGHORIZONTAL MULLION - REFER TO ELEVATION FOR SPACING5A1/4" GLAZING 1/2" AIRSPACE9/16" GLAZINGHORIZONTAL MULLION - REFER TO ELEVATION FOR SPACINGCORE - EXTERIOR STOREFRONT SYSTEM -THERMAL GLAZING -KAWNEER IR501T OR ARCHITECT APPROVED EQUAL5B1/4" GLAZING 1/2" AIRSPACE9/16" GLAZINGHORIZONTAL MULLION - REFER TO ELEVATION FOR SPACINGCORE - EXTERIOR CURTAIN WALL SYSTEM - THERMAL GLAZING - KAWNEER 1600- 1 OR ARCHITECT APPROVED EQUALNOTE - IN WET AREAS AND UNDER TILE CLADDING USE MOISTURE RESISTANT GWB TO CEILING . IN ELECTRICAL ROOMS USE 5/8" PLYWOOD IN LIEU OF GWB TO FLOOR CEILING -PAINTEDFELT BACKED SELF FURRING METAL LATHCONTINUOUS MEMBRANE LAYERCONTINUOUS SCREEDNOTE: SEAL ALL PENETRATIONS IN WALL WITH APPROVED UL DETAILNOTE: FOR ALL METAL STUD WALLS REFER TO MANUFACTURES LIMITING HEIGHT CHARTS AND CALCULATIONS BEFORE SELECTING GAUGE AND SPACING4 1/2"5"2 1/2"2 1/2"7 1/2"2 1/2"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1 1/2" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/26/2017 3:46:03 PMG115PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL TYPES07-14-2017S12014NOTE: REFER TO REFLECTED CEILING PLANS FOR WALLS THAT NEED TO EXTEND TO DECK / ROOFREVISIONS# DATEDESCRIPTIONBY5 09-22-2017 ADDENDUM 555CONFORMED SET18
TILETILE BASE TO BE COVEDFACE OF WALLCONCRETE FLOORTILETRANSITION STRIPTILECARPETTRANSITION STRIPMASTIC ADHESIVESUBFLOOR FILLER TO MEET TRANSITIONTILE AS SCHEDULEDCARPET AS SCHEDULEDCL DOORSOLID SURFACETHRESHOLDMASTIC ADHESIVEVCT/VINYL OR POURED FLOORINGTILETRANSITION STRIPVARIESVARIES2-OB-A7123G1167G11672-OB-A7123TYP.TYP.AT TICKETING LOBBY ONLYAT TICKETING LOBBY ONLY1' - 0"2' - 6"1' - 2"4' - 8"EXISTING COLUMN, PAINTPROVIDE HARDWOOD CAP STAIN TO MATCH MARLITE PANELPLASTIC LAMINATE MARLITE PANEL ON SUBSTRATE DIRECT APPLIED TO EXISTING COLUMNMARLITE 1/4" NARROW SQUARE REVEALBRUSHED STAINLESS STEEL BASE8G116SATIN ANODIZED ALUMINUM TOP EDGEEXISTING COLUMNPLASTIC LAMINATE ON 3/4" SUBSTRATEPANEL CLIPHARDWOOD QUARTER ROUND TOP EDGE, COORDINATE SIZE WITH FINISHED MARLITE PANELING SYSTEM. DIRECT GLUE TO CLEAN SUBSTRATE. STAIN TO MATCH PANEL SYSTEM LAMINATE.1 1/2"1/4"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/26/2017 3:49:45 PMG116PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH DETAILS07-14-2017S12014 3" = 1'-0"1COVE TILE BASE 3" = 1'-0"2TILE TO CONCRETE TRANSITION 3" = 1'-0"3TILE TO CARPET TRANSITION 3" = 1'-0"4TILE TO CARPET TRANSITION @ DOOR 3" = 1'-0"5TILE TO VCT/POURED FLOORTRANSITION 1 1/2" = 1'-0"6COLUMN FINISH DETAIL 1" = 1'-0"7TYPICAL COLUMN ELEVATIONREVISIONS# DATEDESCRIPTIONBY5 09-22-2017 ADDENDUM 5 12" = 1'-0"8COLUMN EDGE TRIM5CONFORMED SET19
GENERAL PROVISIONS1. THE CONTRACTOR SHALL OBTAIN FROM THE OWNER COPIES OF THE ST.JOHNS RIVER WATER MANAGEMENT DISTRICT PERMIT. ALL OTHER PERMITSARE THE RESPONSIBILITY OF THE CONTRACTOR.2. ALL CONSTRUCTION PROJECTS 1 OR MORE ACRES IN SIZE THAT DISCHARGETO OFFSITE AREAS ARE REQUIRED TO COMPLY WITH THE REQUIREMENTSOF THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)GENERAL PERMIT FOR STORMWATER DISCHARGE FROM SMALL AND LARGECONSTRUCTION ACTIVITIES. IN ORDER TO MEET NPDES REQUIREMENTS,THE CONTRACTOR IS RESPONSIBLE FOR PREPARING A STORMWATERPOLLUTION PREVENTION PLAN (SWPPP), IMPLEMENTING, INSPECTING,MAINTAINING, AND REPORTING ON ALL ELEMENTS OF THE SWPPP,COMPLETING AND SUBMITTING THE REQUIRED NOTICE OF INTENT (NOI) ANDNOTICE OF TERMINATION (NOT) FORMS AS THE OPERATOR, AND PAYING ALLASSOCIATED FEES. FOR PROJECTS LESS THAN 1 ACRE IN SIZE THAT ARENOT REQUIRED TO COMPLY WITH THE NPDES GENERAL PERMIT, THECONTRACTOR IS STILL RESPONSIBLE FOR IMPLEMENTING AND MAINTAININGEROSION AND SEDIMENT CONTROL MEASURES PRIOR TO AND DURINGCONSTRUCTION IN ACCORDANCE WITH THE DRAWINGS ANDSPECIFICATIONS.3. UNLESS OTHERWISE NOTED ON THE PLANS, THE CONTRACTOR SHALL USETHE GEOMETRY PROVIDED ON THE CONSTRUCTION PLANS. BENCHMARKINFORMATION SHALL BE PROVIDED TO THE CONTRACTOR BY THE OWNEROR OWNER'S SURVEYOR. ANY DISCREPANCIES BETWEEN FIELDMEASUREMENTS AND CONSTRUCTION PLAN INFORMATION SHALL BEBROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY.4. THE CONTRACTOR SHALL SUBMIT (6) COPIES OF SHOP DRAWINGS TO THEENGINEER FOR APPROVAL PRIOR TO ORDERING THE MATERIALS REQUIREDFOR CONSTRUCTION. PRIOR TO SUBMISSION, THE CONTRACTOR SHALLTHOROUGHLY CHECK SHOP DRAWINGS, PRODUCT DATA, AND SAMPLESFOR COMPLETENESS AND FOR COMPLIANCE WITH THE CONSTRUCTIONPLANS AND SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ANDSHALL COORDINATE THE SHOP DRAWINGS WITH THE REQUIREMENTS FOROTHER RELATED WORK. THE CONTRACTOR'S RESPONSIBILITY FORERRORS AND OMISSIONS IN SUBMITTALS IS NOT RELIEVED BY THEENGINEER'S REVIEW OF SUBMITTALS. THE CONTRACTOR SHALL NOTIFYTHE ENGINEER, IN WRITING AT THE TIME OF SUBMISSION, OF DEVIATIONS INSUBMITTALS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.5. PROTECT BENCHMARKS, PROPERTY CORNERS, AND OTHER SURVEYMONUMENTS FROM DAMAGE OR DISPLACEMENT. IF MARKER NEEDS TO BEREMOVED IT SHALL BE REFERENCED BY LICENSED LAND SURVEYOR ANDREPLACED, AS NECESSARY, BY SAME.6. THE CONTRACTOR IS RESPONSIBLE FOR ALL QUALITY CONTROL TESTING.AS A MINIMUM, TESTING SHALL INCLUDE A) PIPING AND STRUCTURALEXCAVATION, BEDDING AND BACKFILL MATERIALS AND DENSITY TESTS; B)DETERMINATION OF COMPACTIVE EFFORT NEEDED FOR COMPLIANCE WITHTHE DENSITY REQUIREMENTS; C) PORTLAND CEMENT CONCRETE ANDASPHALT PAVING QUALITY CONTROL TESTING INCLUDING DESIGN MIXREVIEW, MATERIALS, FIELD SLUMP AND AIR CONTENT, AND FIELD AND LABCURED STRENGTH SAMPLES AND TESTING.7. IN ADDITION TO QUALITY CONTROL TESTING, THE CONTRACTOR SHALL BERESPONSIBLE FOR REQUIRED TESTING OR APPROVALS FOR ANY WORK (ORANY PART THEREOF) IF LAWS OR REGULATIONS OF ANY PUBLIC BODYHAVING JURISDICTION SPECIFICALLY REQUIRE TESTING, INSPECTIONS ORAPPROVAL. THE CONTRACTOR SHALL PAY ALL COSTS IN CONNECTIONTHEREWITH AND SHALL FURNISH THE OWNER AND ENGINEER THEREQUIRED CERTIFICATES OF INSPECTION, TESTING OR APPROVAL.8. ANY DESIGN OR TESTING LABORATORY UTILIZED BY THE CONTRACTORSHALL BE AN INDEPENDENT LABORATORY ACCEPTABLE TO THE OWNERAND THE ENGINEER, APPROVED IN WRITING, AND COMPLYING WITH THELATEST EDITION OF THE "RECOMMENDED REQUIREMENTS FORINDEPENDENT LABORATORY QUALIFICATION", PUBLISHED BY THEAMERICAN COUNCIL OF INDEPENDENT LABORATORIES.9. TESTING RESULTS SHALL BE PROVIDED TO THE OWNER/OPERATOR ANDTHE ENGINEER. ALL TEST RESULTS SHALL BE PROVIDED (PASSING ANDFAILING) ON A REGULAR AND IMMEDIATE BASIS.10. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL MAKE APRE-CONSTRUCTION VIDEO (DVD FORMAT) ALONG THE PROPOSED ROUTEIN ACCORDANCE WITH THE SPECIFICATIONS. IN PARTICULAR, THE VIDEOSHALL DOCUMENT THE CONDITION OF EXISTING DRIVEWAYS, BUILDINGS,STRUCTURES, MAILBOXES, SIGNS, FENCES, AND LANDSCAPING ALONGPROPOSED CONSTRUCTION AREAS.11. THE ENTIRE PROJECT SITE SHALL BE THOROUGHLY CLEANED AT THECOMPLETION OF THE WORK. CLEAN ALL INSTALLED PIPELINES,STRUCTURES, SIDEWALKS, PAVED AREAS, ACCUMULATED SILT IN PONDS,PLUS ALL ADJACENT AREAS AFFECTED BY CONSTRUCTION, AS DIRECTEDBY THE OWNER OR JURISDICTIONAL AGENCY. EQUIPMENT TO CLEAN THESESURFACES SHALL BE SUBJECT TO APPROVAL BY THE OWNER.AS-BUILT DRAWING REQUIREMENTS1. AS-BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THEENGINEER THREE WEEKS PRIOR TO FINAL INSPECTION. ALL AS-BUILT DATASHALL BE PROVIDED BY A FLORIDA LICENSED SURVEYOR, SIGNED, SEALEDAND DATED BY THE RESPONSIBLE PARTY.2. AT THE COMPLETION OF THE WORK, DELIVER THE DRAWINGSDOCUMENTING AS-BUILT INFORMATION, MEASURED BY A LICENSEDSURVEYOR, TO THE ENGINEER, IN GOOD CONDITION AND FREE FROM ANYEXTRANEOUS NOTATION. THE AS-BUILT INFORMATION IS TO INCLUDE, BUTNOT BE LIMITED TO, THE FOLLOWING:A. HORIZONTAL LOCATIONS AND VERTICAL ELEVATIONS FOR ALL UTILITYAND STORM STRUCTURES INCLUDING BUT NOT LIMITED TO MANHOLES,INLETS AND CLEANOUTS, INCLUDING STRUCTURE TOP AND INVERTELEVATIONS.B. DISTANCE ALONG PIPELINES BETWEEN STRUCTURES.C. STORMWATER POND TOP OF BERM AND POND BOTTOM ELEVATIONSAND HORIZONTAL DIMENSIONS MEASURED AT A MINIMUM OF TENLOCATIONS PER POND, AT LOCATIONS DESIGNATED BY THE ENGINEER.TOP OF POND HORIZONTAL DIMENSIONS ARE ALSO TO BE TIED TOPROPERTY CORNERS, EASEMENTS, AND RIGHTS-OF-WAY.D. STORMWATER CONTROL STRUCTURE DIMENSIONS AND ELEVATIONS,INCLUDING ALL WEIRS, SLOTS, ORIFICES, GRATES, AND SKIMMERS.E. STORMWATER CONVEYANCE SYSTEMS INCLUDING DIMENSIONS,ELEVATIONS, CONTOURS, AND CROSS SECTIONS.F. HORIZONTAL LOCATIONS AND VERTICAL ELEVATIONS OF ALL UTILITYVALVES, FITTINGS, CONNECTION POINTS, ETC.G. VERTICAL ELEVATIONS OF ALL PIPELINES AT CROSSINGS OF POTABLEWATER MAINS (WHETHER THE WATER MAIN IS EXISTING OR NEW) INORDER TO DOCUMENT THAT THE MINIMUM REQUIRED VERTICALSEPARATION HAS BEEN MET.H. UTILITY PIPELINE TIED HORIZONTALLY TO EDGE OF PAVEMENT ANDRIGHT-OF-WAY LINES, LOCATED EVERY 200-FT PLUS ALL CHANGES INHORIZONTAL OFFSET.I. PAVEMENT WIDTH AND ELEVATIONS AT THE CENTERLINE AND EDGE OFPAVEMENT EVERY 300 FEET PLUS AT ALL CHANGES IN LONGITUDINALSLOPE, CROSS SLOPE, INLET LOCATIONS, AND AT ALL DRIVEWAY ANDSTREET INTERSECTIONS. FOR PARKING LOTS, RECORD CENTERLINEAND EDGE OF PAVEMENT ELEVATIONS ALONG ALL DRIVE AISLES ANDISLANDS.STORMWATER POLLUTION PREVENTION REQUIREMENTS1. SUBSTANCES THAT HAVE THE POTENTIAL FOR POLLUTING SURFACEAND/OR GROUNDWATER MUST BE CONTROLLED BY WHATEVER MEANSNECESSARY IN ORDER TO ENSURE THAT THEY DO NOT DISCHARGE FROMTHE SITE. AS AN EXAMPLE, SPECIAL CARE MUST BE EXERCISED DURINGEQUIPMENT FUELING AND SERVICING OPERATIONS. IF A SPILL OCCURS, ITMUST BE CONTAINED AND DISPOSED SO THAT IT WILL NOT FLOW FROM THESITE OR ENTER GROUNDWATER, EVEN IF THIS REQUIRES REMOVAL,TREATMENT, AND DISPOSAL OF SOIL IN ACCORDANCE WITH LOCAL ANDSTATE REGULATIONS.2. ALL PERSONNEL INVOLVED WITH CONSTRUCTION ACTIVITIES MUST COMPLYWITH STATE AND LOCAL SANITARY OR SEPTIC SYSTEM REGULATIONS.TEMPORARY SANITARY FACILITIES SHALL BE PROVIDED AT THE SITETHROUGHOUT THE CONSTRUCTION PHASE FOR USE BY ALL CONSTRUCTIONPERSONNEL AND SHALL BE SERVICED BY A COMMERCIAL OPERATOR ATLEAST ONCE A WEEK.3. DISCHARGES RESULTING FROM GROUNDWATER DEWATERING ACTIVITIESAT CONSTRUCTION SITES ARE PERMITTED PROVIDED THE GROUNDWATERIS FREE OF SEDIMENTS, IS NOT CONTAMINATED, AND DEWATERING OCCURSIN ACCORDANCE WITH STATE AND LOCAL GOVERNING AGENCYREGULATIONS. CONTRACTOR IS RESPONSIBLE FOR FDEP DEWATERINGPERMIT FOR ANY WATER DISCHARGES.4. CHEMICALS, PAINTS, SOLVENTS, FERTILIZERS, AND OTHER TOXIC MATERIALMUST BE STORED IN WATERPROOF CONTAINERS. EXCEPT DURINGAPPLICATION, THE CONTENTS MUST BE KEPT IN TRUCKS OR WITHINSTORAGE FACILITIES. RUNOFF CONTAINING SUCH MATERIAL MUST BECOLLECTED, REMOVED FROM THE SITE, TREATED, AND DISPOSED AT ANAPPROVED SOLID WASTE OR CHEMICAL DISPOSAL FACILITY.5. THE DISCHARGE OF HAZARDOUS SUBSTANCES OR OIL IN THESTORMWATER DISCHARGE(S) FROM A FACILITY OR ACTIVITY SHALL BEPREVENTED. THIS DOES NOT RELIEVE THE OPERATOR OF THE REPORTINGREQUIREMENTS OF 40 CFR PART 117 AND 40 CFR PART 302. THE OPERATORSHALL SUBMIT WITHIN 14 CALENDAR DAYS OF KNOWLEDGE OF THERELEASE A WRITTEN DESCRIPTION OF: THE RELEASE (INCLUDING THE TYPEAND ESTIMATE OF THE AMOUNT OF MATERIAL RELEASED), THE DATE THATSUCH RELEASE OCCURRED, THE CIRCUMSTANCES LEADING TO THERELEASE, AND REMEDIAL STEPS TO BE TAKEN. THE SWPPP MUST BEMODIFIED WITHIN 14 CALENDAR DAYS OF KNOWLEDGE OF THE RELEASE TO:PROVIDE A DESCRIPTION OF THE RELEASE, THE CIRCUMSTANCES LEADINGTO THE RELEASE, AND THE DATE OF THE RELEASE. IN ADDITION, THE PLANMUST BE REVIEWED TO IDENTIFY MEASURES TO PREVENT THEREOCCURRENCE OF SUCH RELEASES AND TO RESPOND TO SUCHRELEASES, AND THE PLAN MUST BE MODIFIED WHERE APPROPRIATE.SITE PREPARATION1. EXERCISE EXTREME CARE DURING THE CLEARING AND GRUBBINGOPERATIONS. DO NOT DAMAGE EXISTING STRUCTURES, PIPES ORUTILITIES.2. GRUBBING SHALL CONSIST OF REMOVING AND DISPOSING OF STUMPS,ROOTS LARGER THAN 2" IN DIAMETER, AND MATTED ROOTS. REMOVE TO ADEPTH OF NOT LESS THAN 18" BELOW THE ORIGINAL SURFACE LEVEL OFTHE GROUND.3. ALL COMBUSTIBLE DEBRIS AND REFUSE FROM SITE PREPARATIONOPERATIONS SHALL BE REMOVED TO LEGAL OFFSITE DISPOSAL AREAS.UTILITY GENERAL NOTES1. THE UTILITY DATA SHOWN ON THESE PLANS WAS LOCATED BY THERESPECTIVE UTILITY, OR IS BASED ON UTILITY DRAWINGS, MAPS, OR FIELDRECONNAISSANCE.2. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN ON THE PLANS HAVEBEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND AREGIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEERASSUMES NO RESPONSIBILITY FOR THEIR ACCURACY. PRIOR TO THESTART OF ANY CONSTRUCTION ACTIVITY, IT SHALL BE THE CONTRACTOR'SRESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE THENECESSARY ARRANGEMENTS FOR ANY RELOCATIONS OF THESE UTILITIESWITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL EXERCISECAUTION WHEN CROSSING AN UNDERGROUND UTILITY, WHETHER SHOWNON THE PLANS OR LOCATED BY THE UTILITY COMPANY. ANY UTILITIES,WHETHER SHOWN ON THESE PLANS OR NOT, THAT INTERFERE WITH THEPROPOSED CONSTRUCTION SHALL BE CLOSELY COORDINATED WITH THEENGINEER AND THE RESPECTIVE UTILITY COMPANY FOR RELOCATION ORPROPER INSTRUCTION.3. A SINGLE POINT UTILITY IDENTIFICATION SERVICE HAS BEEN SET UP FOREXISTING UTILITIES. THE CONTRACTOR IS TO CONTACT THE SUNSHINESTATE ONE CALL CENTER BY DIALING “811” AT LEAST TWO (2) AND NO MORETHAN FIVE (5) WORKING DAYS PRIOR TO THE SPECIFIC CONSTRUCTIONACTIVITY FOR FIELD LOCATION. NOTE THAT NOT ALL UTILITIES PARTICIPATEIN THIS PROGRAM. THE CONTRACTOR SHOULD CONTACT ALLNON-PARTICIPATING UTILITIES SEPARATELY FOR FIELD LOCATION OF THEIRFACILITIES AT LEAST TWO (2) WORKING DAYS PRIOR TO CONSTRUCTION.PER FLORIDA STATUTE 553.851, THE CONTRACTOR OR EXCAVATOR ISREQUIRED TO NOTIFY THE GAS COMPANY TWO (2) WORKING DAYS PRIORTO STARTING EXCAVATION.4. THE FOLLOWING UTILITIES HAVE PREVIOUSLY INDICATED THAT THEY MAYHAVE FACILITIES IN THE VICINITY OF THE CONSTRUCTION AREA:AT&TATTN: SCOTT LORENZ132 COMMERCE WAYSANFORD, FL 32771407-302-7611BRIGHT HOUSE NETWORKSATTN: MARVIN USRY3767 ALL AMERICAN BLVD.ORLANDO, FL 32810407-532-8509 FAA TECH OPS ATTN: JACK WIGGINS 1580 AVIATION CENTRAL PKWY DAYTON BEACH, FL 32114 386-226-3955FLORIDA POWER & LIGHTATTN: MARIANNE DILLARD2626 WEST STATE RD 46SANFORD, FL 32771407-328-1922 FLORIDA PUBLIC UTILITIES ATTN: DAN SCRIBBEN 450 S. CHARLES RICHARD BEALL BLVD. DEBARY, FL 32713386-668-26005. THE CONTRACTOR SHALL KEEP LOCATE TICKETS UP TO DATE AT ALL TIMES.6. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION WITH EACH UTILITYAND ALL COSTS ASSOCIATED WITH THE PROTECTION OF EXISTING FACILITIESDURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATENECESSARY RELOCATIONS OR OTHER CONSTRUCTION RELATED MATTERS WITHEACH UTILITY.7. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN IN SERVICE ALLEXISTING PIPING ENCOUNTERED DURING CONSTRUCTION UNLESS OTHERWISEINDICATED IN THE DRAWINGS. ANY PIPING WHICH CAN BE REMOVED DURINGCONSTRUCTION WITHOUT UNDUE INTERRUPTION OF SERVICE MAY BE REMOVEDAND REPLACED BY THE CONTRACTOR WITH THE PERMISSION OF THE OWNER ANDTHE ENGINEER.8. THE CONTRACTOR SHALL FIELD LOCATE ALL WATER AND SEWER SERVICES ANDLATERALS WITHIN THE PROPOSED CONSTRUCTION AREA PRIOR TOCONSTRUCTION AND ADJUST THE PROPOSED CONSTRUCTION AS NEEDED TOACCOMMODATE THESE EXISTING LINES.9. TYPICAL DETAILS AND PROPOSED CONSTRUCTION AS SHOWN ILLUSTRATE THEENGINEER'S INTENT AND ARE NOT PRESENTED AS A SOLUTION TO ALLCONSTRUCTION PROBLEMS ENCOUNTERED IN THE FIELD. THE CONTRACTOR MAYALTER THE PROPOSED CONSTRUCTION TO SUIT FIELD CONDITIONS, PROVIDED ITCOMPLIES WITH THE PROJECT SPECIFICATIONS AND APPROVAL IS RECEIVED FROMTHE ENGINEER OR THE AIRPORT. WHERE SUCH PROPOSED REVISIONS DEVIATEFROM THE FDEP CONSTRUCTION PERMIT, THEN SUCH REVISIONS WILL ALSOREQUIRE APPROVAL FROM FDEP.10. FOR EACH RESPECTIVE PIPELINE CONSTRUCTION REQUIRED, THE CONTRACTORSHALL FIELD VERIFY THE LOCATION, DEPTH, AND ALIGNMENT OF ALL EXISTINGPIPES, CABLES, ETC. TO BE CROSSED OR CONNECTED TO. IF THE CONTRACTORDEEMS NECESSARY (A) A CHANGE IN ALIGNMENT OR DEPTH, OR THE NEED FORADDITIONAL FITTINGS, BENDS, OR COUPLINGS, WHICH REPRESENT A DEPARTUREFROM THE CONTRACT DRAWING, OR (B) A NEED FOR RELOCATION OF EXISTINGUTILITIES, THEN DETAILS OF SUCH DEPARTURES, RELOCATIONS, OR ADDITIONALFITTINGS, INCLUDING CHANGES IN RELATED PORTIONS OF THE PROJECT AND THEREASONS THEREFORE, SHALL BE SUBMITTED WITH SHOP DRAWINGS. APPROVEDDEPARTURES FOR THE CONTRACTOR'S CONVENIENCE SHALL BE MADE AT NOADDITIONAL COST TO THE OWNER.11. THE CONTRACTOR SHALL PROVIDE AT HIS OWN EXPENSE ALL NECESSARY TESTPUMPING EQUIPMENT, WATER, WATER METERS, PRESSURE GAUGES, AND OTHEREQUIPMENT, MATERIAL AND FACILITIES REQUIRED FOR ALL HYDROSTATIC,LEAKAGE, AND PRESSURE TESTING. THE CONTRACTOR SHALL CONTACT THEENGINEER AND THE OWNER IN WRITTEN FORM, FORTY-EIGHT (48) HOURS INADVANCE OF PROPOSED TESTING. THE CONTRACTOR SHALL PERFORMSATISFACTORY PRETESTING PRIOR TO NOTIFICATION. SAA ITATTN: JERRY COCKER 1200 RED CLEVELAND BLVD. SANFORD, FL 32773 407- 585-4005SAA CONTROLATTN: TIFFANY VINCENT 1200 RED CLEVELAND BLVD. SANFORD, FL 32773 407-585-4101 SEMINOLE COUNTY FIBERATTN: JIM PORTER1101 EAST 1st STREETSANDFORD, FL 32771407-665-7444CITY OF SANFORDATTN: PAUL MOORE, UTILITY DIRECTOR300 N. PARK AVENUESANFORD, FL 32771407-688-5106J. HORIZONTAL AND VERTICAL DATA FOR ANY CONSTRUCTION THATDEVIATES FROM THE APPROVED ENGINEERING DRAWINGS.K. WHERE THE PLANS CONTAIN SPECIFIC HORIZONTAL LOCATION DATA,SUCH AS STATION AND OFFSET, THE AS-BUILT DRAWINGS ARE TOREFLECT THE ACTUAL HORIZONTAL LOCATION.L. WHERE THE PLANS CONTAIN SPECIFIC VERTICAL ELEVATION DATA, THEAS-BUILT DRAWINGS ARE TO REFLECT THE ACTUAL MEASUREDVERTICAL ELEVATION.Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014GENERAL NOTESIBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037CONFORMED SET20
GENERAL NOTES1. ALL CONTRACTOR VEHICLES AND TRAFFIC SHALL REMAIN WITHIN THE DESIGNATEDSTAGING AREA, CONSTRUCTION LIMITS OR HAUL ROUTES.2. ALL DRAINAGE STRUCTURES AND PIPES WITHIN THE CONSTRUCTION LIMITS ARE TOREMAIN UNLESS OTHERWISE NOTED.3. THE CONTRACTOR IS ADVISED THAT ALL EMPLOYEES WORKING INSIDE THE SECUREFENCE MUST CONFORM WITH ALL AIRPORT SECURITY REQUIREMENTS AS OUTLINEDIN SECTION 4 "SAFETY AND SECURITY REQUIREMENTS" OF THE SPECIAL PROVISIONS.4. AIRPORT OPERATIONS STAFF SHALL HAVE THE AUTHORITY TO SUSPENDCONSTRUCTION OPERATIONS AT ANY TIME; DUE TO WEATHER, UNSAFE WORKINGCONDITIONS OR WHEN DEEMED TO BE IN THE BEST INTEREST OF THE AIRPORT.5. THE AIRPORT WILL BE IN OPERATION DURING THE CONSTRUCTION OF THIS PROJECT.COORDINATION OF WORK WITH AIRPORT MANAGEMENT IS MANDATORY SO AS TOMINIMIZE IMPACTS ON AIRPORT OPERATIONS. OPERATION OF THE AIRPORT IS OF THEUPPER MOST IMPORTANCE. WHEN THERE IS CONFLICT BETWEEN OPERATION OF THEAIRPORT AND CONSTRUCTION, OPERATION OF THE AIRPORT WILL HAVE PRIORITY.6. EXISTING GRADES SHOWN ON THE DRAWINGS ARE BELIEVED TO BE ACCURATE, BUTTHE AIRPORT ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OF THESE GRADES.IF THE CONTRACTOR DOES NOT CONCUR WITH THE ELEVATIONS GIVEN ON THEDRAWINGS, HE SHALL NOTIFY THE ENGINEER IN WRITING PRIOR TO INITIATING ANYCONSTRUCTION ACTIVITIES. START OF WORK BY THE CONTRACTOR WITHOUT SUCHNOTIFICATION WILL BE INTERPRETED AS AN AGREEMENT BY THE CONTRACTOR WITHTHE ACCURACY OF THE GRADES SHOWN ON THE PLANS.7. THE CONTRACTOR SHALL FAMILIARIZE HIS PERSONNEL WITH CLEARANCES NEEDEDTO PROVIDE FOR THE SAFE OPERATION OF RUNWAYS AND TAXIWAYS AS SHOWN ONSHEET G-1.00 PHASE 1, G2.00 PHASE 2 AND G3.00 PHASE 3.8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING AND ACQUIRING ALLREQUIRED COUNTY AND STATE PERMITS.9. THE CONTRACTOR SHALL REVIEW ALL AIRPORT UTILITIES WITH AIRPORTMANAGEMENT PRIOR TO BEGINNING WORK.10. THE PROJECT PAY ITEMS ARE PROVIDED TO BE INCLUSIVE OF ALL WORK TO BEPERFORMED AS SHOWN IN THESE PLANS. ALL INCIDENTAL WORK REQUIRED TOCOMPLETE THE PROJECT IS TO BE INCLUDED IN THE COSTS OF PERFORMING THESEITEMS.11. TESTING - UNLESS OTHERWISE SPECIFIED, ALL QUALITY ASSURANCE (QA) TESTINGREQUIRED BY THE SPECIFICATIONS FOR ACCEPTANCE OF WORKMANSHIP AND/ORMATERIALS SHALL BE INITIATED AND PAID FOR BY THE OWNER. QUALITY CONTROL(QC) TESTING SHALL BE INITIATED AND PAID FOR BY THE CONTRACTOR. FAILED QATESTING SHALL REQUIRE RE-TESTING WHICH SHALL BE INITIATED BY THE ENGINEERAND PAID FOR BY THE CONTRACTOR.MAINTENANCE OF TRAFFIC AND SAFETY1. THE CONTRACTOR IS ADVISED THAT ALL AIRPORT ROADWAYS, EXCEPT THOSE THATARE TO BE CONSTRUCTED UNDER THIS CONTRACT, WILL BE ACTIVE DURING THISCONTRACT. THE CONTRACTOR WILL BE EXPECTED TO CONDUCT THE WORK SUCHTHAT THE SAFETY OF OPERATIONS IS NOT REDUCED AND THAT VEHICULAR FLOW ISMAINTAINED AT ALL TIMES, EXCEPT AS SPECIFICALLY PROVIDED FOR IN THECONTRACT DOCUMENTS OR ALLOWED BY THE OWNER IN WRITING. THECONTRACTOR IS ADVISED, AND SHALL ACCEPT AS AN IMPORTANT CONSIDERATION OFTHE WORK, THAT THE MAINTENANCE OF SAFE AND EFFICIENT ACCESS TO THEAIRPORT VIA THE ROADWAY SYSTEM IS AN INTEGRAL PART OF THE WORK. IN CASESNOT SPECIFICALLY COVERED ELSEWHERE IN THE CONTRACT DOCUMENTS, ALLTRAFFIC MAINTENANCE SHALL BE ACCOMPLISHED IN CONFORMANCE TO THE LATESTEDITION OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD).2. THE CONTRACTOR SHALL INSTALL AND MAINTAIN FOR THE DURATION OF THEPROJECT ALL "TRUCKS ENTERING HIGHWAY" SIGNS. THE SIGNS MUST BE INACCORDANCE WITH STATE OF FLORIDA CONSTRUCTION AND MATERIALSPECIFICATIONS, AND WILL BE PLACED/INSTALLED AS DIRECTED BY AIRPORTPERSONNEL. THE COST SHALL BE INCLUDED IN THE APPROPRIATE CONSTRUCTIONITEMS.DUST AND DEBRIS CONTROL1. THE CONTRACTOR SHALL PAY PARTICULAR ATTENTION TO THE DUST CONTROLREQUIREMENTS OF THIS CONTRACT. THE OPERATIONS OF THE RUNWAYS, TAXIWAYS,AND ASSOCIATED NAVAIDS ARE ESPECIALLY SENSITIVE TO DUST. THE CONTRACTORSHALL BE PREPARED TO CONTROL DUST ON HAUL ROUTES ON A DAILY BASIS.WATERING, OR OTHER APPROVED DUST CONTROL MEASURES SHALL BE AVAILABLEON A DAILY BASIS TO CONTROL DUST. THE OWNER RESERVES THE RIGHT TO STOPGRADING AND HAULING, OR OTHER WORK IF NECESSARY, TO BRING DUST UNDERCONTROL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DUST CONTROL WITHINTHE CONSTRUCTION LIMITS AS WELL AS ALONG ANY ROADWAYS USED BY THEEQUIPMENT AND VEHICLES AT THE SOLE DISCRETION OF THE AIRPORT.2. THE CONTRACTOR SHALL PROVIDE A FIBER BRISTLE PAVEMENT SWEEPER FORKEEPING DEBRIS CLEAR AT ALL OPERATIONAL PAVEMENT CROSSING AREAS ON THEHAUL ROUTE AS REQUIRED BY AIRPORT OPERATIONS.3. ALL UNSUITABLE MATERIAL AND CONSTRUCTION DEBRIS SHALL BE DISPOSED OF OFFOF AIRPORT PROPERTY UNLESS DIRECTED OTHERWISE BY THE ENGINEER ORAIRPORT PERSONNEL.4. SPECIFICATIONS ARE PROVIDED AS OUTLINE REQUIREMENTS FOR THE CONTRACTORTO APPLY WATER, CHEMICALS, VEGETATION OR OTHER MATERIALS TO PREVENT THEOCCURRENCE OF DUST WHICH WILL BE OBJECTIONABLE TO THE OPERATIONS/USERSOF THE AREA. THESE SHALL INCLUDE, BUT ARE NOT LIMITED TO, AIRPORTOPERATIONS AND MAINTENANCE AREAS; AIRCRAFT OPERATIONS AND AIRFIELDOPERATIONS. CONTRACTOR SHALL ALSO BE OBLIGATED TO DISCONTINUEOPERATIONS WHICH VIOLATE EXISTING LAWS AND REGULATIONS OR CREATE ANUNDUE HAZARD TO AIR TRAFFIC. ALL COSTS FOR CONTROLLING DUST ORPOLLUTANTS TO THE AIR OF ANY KIND SHALL BE INCIDENTAL TO THE CONTRACT.STORAGE, STAGING AND HAUL ROADS1. STORAGE AND STAGINGA) THE CONTRACTOR SHALL USE THE STORAGE AND STAGING AREA SPECIFIED FORSTOCKPILES, SHOPS, MAINTENANCE FACILITIES USE OF AND ALL CONTRACTORSUPPORT FACILITIES. NO OTHER SITES SHALL BE PERMITTED ON AIRPORTPROPERTY WITHOUT WRITTEN APPROVAL FROM THE ENGINEER AND OWNER.B) ALL COSTS ASSOCIATED WITH PREPARING THE STORAGE AND STAGING AREA SITESHALL BE BORNE BY THE CONTRACTOR. THIS INCLUDES BUT IS NOT LIMITED TO,CLEARING AND GRADING OF THE SITE, CONSTRUCTION OF ALL TEMPORARYUTILITIES, ACCESS ROADS, ALL SECURITY FENCING, ETC. AT THE CONCLUSION OFTHE CONTRACT THEM CONTRACTOR SHALL RESTORE THE SITE TO ITSPRE-CONSTRUCTION CONDITION.2. HAUL ROADSA) HAUL ROADS TO BE USED UNDER THIS PROJECT SHALL BE THOSE INDICATED ONTHE DRAWINGS OR OTHERWISE SPECIFICALLY DESIGNATED BY THEOWNER/ENGINEER. IN GENERAL, THE CONTRACTOR SHALL CONFINE EQUIPMENTAND HAULING TO THE AREAS UNDER CONSTRUCTION. NO DEBRIS SHALL BEALLOWED ON THE ROADWAYS. THE PAVEMENT WILL BE CLEANED BY THECONTRACTOR USING POWER BROOMS OR SWEEPERS, AS REQUIRED, TO KEEP THEAREA CLEAR OF ALL SOILS, CLODS OR OTHER DEBRIS. THE CONTRACTOR SHALLHAVE A BROOM TRACTOR ON SITE AT ALL TIMES WITH A POLY BRUSH. STEELBRUSHES ARE NOT PERMITTED.B) ALL DELIVERIES TO THE STAGING AREA SHALL BE VIA THE HAUL ROUTES AS SHOWNON THE PLANS.C) THE ACCESS POINTS TO THE PROJECT SITE SHALL BE AS DEFINED ON SHEET C-3.00.THE SPECIFIED GATE AREAS SHALL BE MONITORED DURING ALL CONTRACTOROPERATIONS. IF IT IS DETERMINED BY THE OWNER/ENGINEER THAT THECONTRACTOR'S HAULING OPERATIONS ARE CAUSING EXCESSIVE DAMAGE TO THEEXISTING GATES OR PAVEMENT AREAS, THE CONTRACTOR MAY BE REQUIRED TOCONSTRUCT, AT HIS EXPENSE, ADDITIONAL ACCESS GATES IMMEDIATELY ADJACENTTO THE EXISTING GATES. HE SHALL MAINTAIN THE NEW ACCESS POINTS ANDPROVIDE THE AFOREMENTIONED GATE GUARDS AT THESE LOCATIONS AND SHALLASSUME ALL LIABILITY FOR AIRPORT SECURITY RELATING TO THE USE OF THESEGATES.D) IF NECESSARY, THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR RESTORINGALL AIRPORT SERVICE ROADS, INCLUDING THE PERIMETER SERVICE ROAD, TOTHEIR PRE-CONSTRUCTION CONDITION WHERE SUCH ROADS ARE USED BY THECONTRACTOR FOR HAULING OPERATIONS. THE CONTRACTOR AND THE ENGINEERSHALL JOINTLY DETERMINE THE EXISTING CONDITIONS AS A BASIS FOR THISRESTORATION REQUIREMENT.E) THE CONTRACTOR SHALL RESTORE ALL TURFED AND PAVED AREAS USED FOR HAULROADS TO THEIR ORIGINAL CONDITION, INCLUDING THE ESTABLISHMENT OF TURF.ALL HAULING ALONG OR CROSSING THE AIRPORT AND STATE ROADS SHALL BEACCOMPLISHED IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OFTRANSPORTATION STANDARDS AND SHALL BE COORDINATED BY ANDACCOMPLISHED BY THE CONTRACTOR. ALL COSTS FOR CONSTRUCTING, REMOVINGAND RESTORING OF HAUL ROADS REQUIRED FOR THE COMPLETION OF THE WORKSHALL BE INCLUDED IN THE APPROPRIATE ITEMS OF WORK CONTAINED IN THEPROPOSAL.3. OTHER CONTRACTORS AND AIRPORT EMPLOYEE PARKING AREASA) THE CONTRACTOR IS ADVISED THAT OTHER CONTRACTORS MAY BE WORKING ONTHE AIRPORT, AND COOPERATION BETWEEN CONTRACTORS IS REQUIRED.STAGING AREAS - GENERAL REQUIREMENTS1. THE LOCATION AND SIZE OF THE CONTRACTOR'S STAGING AREA IS SHOWN FORREFERENCE ONLY. THE ACTUAL SIZE AND EXACT LOCATION WILL BE ESTABLISHEDPRIOR TO CONSTRUCTION. THE FOLLOWING REQUIREMENTS WILL APPLY, HOWEVER:A) ALL OF THE CONTRACTOR'S ACTIVITIES, INCLUDING EMPLOYEE PARKING AND FIELDOFFICE WILL BE STAGED FROM THIS AREA. THE CONTRACTOR WILL BERESPONSIBLE FOR TRANSPORTING EMPLOYEES FROM THE STAGING AREAS TOAND FROM THE WORK AREA.B) THE STAGING AREA IS, AND WILL REMAIN THROUGHOUT THE CONSTRUCTION,OUTSIDE THE AOA. IT WILL NOT BE NECESSARY, THEREFORE, TO ERECT AIRPORTSECURITY FENCING AROUND THE AREA. HOWEVER, THE CONTRACTOR MAY, ANDIS URGED TO ERECT SECURITY FENCING TO DELINEATE AND PROTECT THE AREA.COST OF ANY FENCING AND OTHER WORK REQUIRED TO PREPARE THE STAGINGAREA SHALL BE INCIDENTAL TO MOBILIZATION.C) THE CONTRACTOR MAY DO SOME GRADING AND DRAINAGE WORK TO ADAPT THEAREA TO SPECIFIC NEEDS. THE CONTRACTOR SHALL OBTAIN NECESSARYPERMIT(S) TO DEVELOP AND USE THE SITE FOR STAGING AND OTHER ACTIVITIESAS REQUIRED. UPON COMPLETION OF THE WORK, THE AREA WILL BE DRESSED,SODDED AND RESTORED TO THE OWNER'S SATISFACTION.D) IT IS NOT ANTICIPATED THAT THE AIRPORT'S OBSTRUCTION HEIGHTREQUIREMENTS, AS DEFINED BY THE FAR PART 77, WILL RESTRICT THECONTRACTOR'S ACTIVITIES IN THE STAGING AREA. IT IS REQUIRED, HOWEVER,THAT THIS ASSUMPTION BE VERIFIED BY THE CONTRACTOR THROUGH THE OWNERPRIOR TO BEGINNING WORK.E) THE OWNER MAY, AT ITS DISCRETION, DESIGNATE THAT STAGING AREAS FOROTHER CONTRACTORS BE LOCATED IN THE VICINITY. IF THIS OCCURS, THECONTRACTOR SHALL COOPERATE, AS NECESSARY, TO ACCOMMODATE OTHERS.F) THE CONTRACTOR WILL BE REQUIRED TO OBSERVE ALL EXISTING TRAFFIC FLOWDIRECTIONS WHEN ENTERING AND LEAVING THE STAGING AREAS. NO COUNTERFLOW WILL BE ALLOWED ANY TIME.2. MATERIAL AND EQUIPMENT STORAGE SHALL BE LOCATED AS SHOWN ON THE SAFETYPLAN SHEET(S). THE CONTRACTOR SHALL ADVISE ALL MATERIAL SUPPLIERS OF THEDELIVERY ROUTES TO BE USED FOR THE DELIVERY OF EQUIPMENT, MATERIALS, ORSUPPLIES. THE CONTRACTOR SHALL ALSO ADVISE THE SUPPLIERS THAT THERE WILLBE SET DELIVERY HOURS AND THEY WILL NOT BE ACCEPTED AT ANY OTHER TIME.DELIVERY HOURS WILL BE FROM 8:00 AM TO 4:00 PM WEEKDAYS UNLESS PRIORARRANGEMENTS WITH AIRPORT PERSONNEL ARE MADE 48 HOURS IN ADVANCE. ANYDELIVERIES NOT MADE DURING THESE HOURS STATED WILL BE TURNED AWAY BYAIRPORT PERSONNEL. A REPRESENTATIVE OF THE CONTRACTOR MUST BE PRESENTFOR DELIVERY OF MATERIALS. MATERIALS AND EQUIPMENT NOT IN USE SHALL BESTORED OR PARKED IN AREAS DESIGNATED BY THE ENGINEER AND OUTSIDE OF THERIGHT-OF-WAY AND TAXIWAY SAFETY ZONES. THE CONTRACTOR SHALL BERESPONSIBLE FOR RESTRICTING HIS/HER EQUIPMENT AND PERSONNEL TO THEIMMEDIATE VICINITY OF CONSTRUCTION AND TO AUTHORIZE AREAS AND SHALL TAKESUCH PRECAUTIONS, AT HIS OWN EXPENSE, AS ARE NECESSARY TO ASSURECOMPLIANCE WITH THESE REQUIREMENTS.3. ALL MATERIALS AND EQUIPMENT, WHEN NOT IN USE, SHALL BE PLACED IN APPROVEDAREAS WHERE THEY WILL NOT CONSTITUTE A HAZARD TO AIRPORT OPERATIONS.TALL BUT RELATIVELY LOW-VISIBILITY (I.E. CRANES, BACK HOES, DRILLS, ETC.)EQUIPMENT SHALL BE STORED IN A LOWERED CONFIGURATION WHEN NOT IN USE.THE APPROVED STORAGE AREA FOR EQUIPMENT AND MATERIALS IS THECONTRACTOR'S STAGING AREA. ANY OTHER AREAS TO BE USED FOR STORAGE MUSTBE APPROVED BY THE ENGINEER AND OWNER PRIOR TO USE. EQUIPMENT AND/ORSTOCKPILED MATERIALS SHALL BE STORED IN A MANNER TO PREVENT MOVEMENTRESULTING FROM WIND CONDITIONS.CONSTRUCTION PHASING REQUIREMENTS1. THE CONSTRUCTION PHASING AS SHOWN IN THESE CONTRACT DOCUMENTS IS ASIMPLIFIED PHASE DESCRIPTION SHOWING GENERAL RELATIVE TIME FRAMES WITHINWHICH CONSTRUCTION WORK WILL BE ACCOMPLISHED. THE CONTRACTOR SHALLDEVELOP HIS OWN CONSTRUCTION SCHEDULE IN ACCORDANCE WITH THEREQUIREMENTS OF THE SPECIFICATIONS AND DRAWINGS. THE CONTRACTOR SHALLSUBMIT THIS PLAN FOR REVIEW AND APPROVAL A MINIMUM OF 72 HOURS PRIOR TOTHE START OF CONSTRUCTION.2. THE CONTRACTOR SHALL ALLOW A MINIMUM OF 30 DAYS CURING TIME FOR ALL NEWASPHALT PAVEMENTS PRIOR TO APPLICATION OF TRAFFIC PAINT. NO ADDITIONALCONTRACT TIME SHALL BE GRANTED FOR DELAYS DUE TO THIS REQUIREMENT.SECURITY NOTES1. THE CONTRACTOR SHALL CONDUCT HIS/HER ACTIVITIES IN A SAFE AND SECUREMANNER AS SPECIFIED IN SECTION 4 "SAFETY AND SECURITY REQUIREMENTS" OFTHE SPECIAL PROVISIONS IN THE SPECIFICATIONS AND AS DESCRIBED HEREIN.2. THE CONTRACTOR SHALL COMPLY WITH ALL SECURITY REQUIREMENTS SPECIFIEDHEREIN, AND ALL FURTHER DIRECTIVES SPECIFIED BY THE OWNER OR DESIGNATEDREPRESENTATIVE. CONTRACTOR SHALL FURTHER BE REQUIRED TO PAY ALL FINESLEVIED BY THE TRANSPORTATION SECURITY ADMINISTRATION OR OTHERAUTHORIZED GOVERNMENTAL AUTHORITY FOR VIOLATIONS OF TSA RULES ANDREGULATIONS OR THE AIRPORT SECURITY PLAN.3. CONTRACTOR PERSONNEL SECURITY ORIENTATION - THE CONTRACTOR SECURITYPOINT OF CONTACT SHALL BE RESPONSIBLE FOR BRIEFING ALL CONTRACTORPERSONNEL ON THESE REQUIREMENTS AND, FROM TIME TO TIME, OTHER SECURITYPROVISIONS. ALL NEW CONTRACTOR EMPLOYEES SHALL BE BRIEFED ON THESEREQUIREMENTS PRIOR TO WORKING IN THE CONSTRUCTION AREA.4. ACCESS TO THE SITE - ALL CONSTRUCTION PERSONNEL MUST FOLLOW THEAIRPORT'S LATEST SECURITY AND BADGING REQUIREMENTS. CONTRACTOR'SACCESS TO THE SITE SHALL BE AS SHOWN ON THE PLANS OR AS DIRECTED BY THEENGINEER. THE CONTRACTOR SHALL NOT PERMIT ANY UNAUTHORIZEDCONSTRUCTION PERSONNEL OR TRAFFIC ON THE SITE. THE CONTRACTOR SHALL BERESPONSIBLE FOR TRAFFIC CONTROL TO AND FROM THE VARIOUS CONSTRUCTIONAREAS ON THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR THE IMMEDIATECLEANUP OF ANY DEBRIS DEPOSITED ALONG THE HAUL ROAD AS A RESULT OFCONSTRUCTION TRAFFIC.5. MATERIALS DELIVERY TO THE SITE - ALL CONTRACTOR'S MATERIAL ORDERS FORDELIVERY TO THE SITE WILL USE THE ACCESS POINT AT THE CONTRACTOR'SSTORAGE SITE.6. CONSTRUCTION AREA LIMITS - THE LIMITS OF CONSTRUCTION, MATERIAL STORAGEAREAS, EQUIPMENT STORAGE AREA, PARKING AREA AND OTHER AREAS DEFINED ASREQUIRED FOR THE CONTRACTOR'S EXCLUSIVE USE DURING CONSTRUCTION SHALLBE MARKED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER AND OWNER.THE CONTRACTOR MAY ERECT AND MAINTAIN AROUND THE PERIMETER OF THESEAREAS SUITABLE FENCING, SIGNAGE AND WARNING DEVICES VISIBLE FOR BOTHDAY/NIGHT USE TO DELINEATE THE PERIMETER OF ALL SUCH AREAS.SANFORD AIRPORT AUTHORITY BOARD MEMBERSPROJECT ENGINEER / SURVEYORORLANDO SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFAA AIP NO. FDOT FM No. SANFORD AIRPORT AUTHORITYGENERAL CONTRACTORPROJECT FUNDED BY:FLORIDA DEPARTMENT OF TRANSPORTATION / FAA.4"x4"x12"TREATEDWOOD POSTEXISTING GROUND3/4" PLYWOOD A-CEXT. APA GROUP 1PROJECT AND CONSTRUCTION ACCESS SIGN NOTES:1. THE PROJECT SIGN LETTERING SHALL BE BLACK (NON-REFLECTIVE) WITH A WHITE BACKGROUND.2. SIGN SHALL BE LOCATED BY CONTRACTOR AS DIRECTED BY OWNER.PROJECT SIGN DETAILNTSFOR SAA STAFF &BRD. MEMBERS LISTSEE COVERDIANE CREWS, A.A.E.GRORGE D. SPEAKE, C.M.FRANK S. LOPPOLO, JR., ESQ.TIM M. SLATTERYJENNIFER T. DANE, ESQ.U. HENRY BOWLINWILLIAM R. MILLERCLYDE H. ROBERTSON, JR.CLAYTON D. SIMMONS, ESQ.STEPHEN P. SMITHA.K. SHOEMAKERKENNETH W. WRIGHT- PRESIDENT AND CEO- VICE PRESIDENT, OPERATIONS AND MAINTENANCE- CHAIRMAN- VICE CHAIRMAN- SECRETARY / TREASURER- BOARD MEMBER- BOARD MEMBER- BOARD MEMBER- BOARD MEMBER- BOARD MEMBER- CHAIRMAN EMERITUS- COUNSELOffices In:FloridaPuerto RicoConnecticutMarylandTexasACCESS ROUTE AND STAGING NOTES1. MAINTENANCE OF TRAFFIC AND SAFETYA) THE CONTRACTOR SHALL USE THE STORAGE AND STAGING AREA SPECIFIED FORSTOCKPILES, SHOPS, MAINTENANCE FACILITIES USE OF AND ALL CONTRACTORSUPPORT FACILITIES. NO OTHER SITES SHALL BE PERMITTED ON AIRPORTPROPERTY WITHOUT WRITTEN APPROVAL FROM THE ENGINEER AND OWNER.2. STAGING AREAS - GENERAL REQUIREMENTS - TO BE DETERMINEDTHE LOCATION AND SIZE OF THE CONTRACTOR'S STAGING AREA IS SHOWN IN SHEETG-1.00, G-2.00 AND G-3.00 FOR REFERENCE ONLY. THE ACTUAL SIZE AND EXACTLOCATION WILL BE ESTABLISHED PRIOR TO CONSTRUCTION. THE FOLLOWINGREQUIREMENTS WILL APPLY, HOWEVER:A) ALL OF THE CONTRACTOR'S ACTIVITY WILL BE STAGED FROM THESE AREAS. ALLFIELD OFFICE AND EMPLOYEE PARKING WILL BE LOCATED AS SHOWN ON SHEETSG-1.00 PHASE 1, G2.00 PHASE 2, G3.00 PHASE 3. THE CONTRACTOR WILL BERESPONSIBLE FOR TRANSPORTING EMPLOYEES FROM THE STAGING AREAS TO ANDFROM THE WORK AREA. ADDITIONAL INTERMEDIATE STAGING AREAS MAY BEAVAILABLE TO THE CONTRACTOR AFTER COORDINATION WITH THE SAAOPERATIONS.B) THE CONTRACTOR SHALL BE RESPONSIBLE TO INITIATE AND PAY FOR THE NOTICEOF INTENT (NOI) FOR STORM WATER POLLUTION PREVENTION FOR EPA, NPDES ANDFDEP. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE TO INITIATE AND SUBMITTHE NPDES NOTICE OF TERMINATION (NOT) UPON PROJECT COMPLETION.C) IT IS NOT ANTICIPATED THAT THE AIRPORT'S OBSTRUCTION HEIGHT REQUIREMENTS,AS DEFINED IN FAA'S FAR PART 77, WILL RESTRICT THE CONTRACTOR'S ACTIVITIESIN THE PRIMARY STAGING AREA. IT IS REQUIRED, HOWEVER, THAT THISASSUMPTION BE VERIFIED BY THE CONTRACTOR THROUGH SAA OPERATIONS PRIORTO BEGINNING WORK. THE MAXIMUM HEIGHT OF EQUIPMENT ALLOWED IS 15 FEET.ANY OPERATION OF EQUIPMENT THAT EXCEEDS 15 FEET WILL REQUIRE APPROVALBY SAA OPERATIONS.D) THE AUTHORITY MAY, AT ITS DISCRETION, DESIGNATE THAT STAGING AREAS FOROTHER CONTRACTORS BE LOCATED IN THE VICINITY. HAUL ROADS WILL BE USED BYOTHER CONTRACTORS, IF THIS OCCURS, THE CONTRACTOR SHALL COOPERATE, ASNECESSARY, TO ACCOMMODATE OTHER CONTRACTORS WORK ACTIVITIES.E) THE CONTRACTOR SHALL PROVIDE PROFESSIONALLY-MADE SIGNS INDICATING THENAME OF THE CONTRACTOR AND A MESSAGE DIRECTING ALL MATERIALSDELIVERIES TO THE PRIMARY STAGING AREA. INCLUDE THE COST OF FABRICATIONAND ERECTION IN ITEM M-101-1, MOBILIZATION PAY ITEM.F) UPON COMPLETION OF THE PROJECT THE CONTRACTOR SHALL REMOVE ALL SITEIMPROVEMENTS AND RESTORE THE AREA TO THE SAA'S SATISFACTION.G) THE CONTRACTOR SHALL USE THE STORAGE AND STAGING AREAS SPECIFIED FORSTOCKPILES, SHOPS, MAINTENANCE FACILITIES AND ALL CONTRACTOR SUPPORTFACILITIES. NO OTHER SITES SHALL BE PERMITTED ON AIRPORT PROPERTYWITHOUT WRITTEN APPROVAL FROM THE ENGINEER AND THE SANFORD AIRPORTAUTHORITY (SAA).H) ALL COSTS ASSOCIATED WITH PREPARING THE STORAGE AND STAGING AREA SITESHALL BE BORNE BY THE CONTRACTOR. THIS INCLUDES BUT IS NOT LIMITED TO,CLEARING AND GRADING OF THE SITE, CONSTRUCTION OF ALL TEMPORARYUTILITIES, PERMITTING, ACCESS ROADS, ALL SECURITY FENCING, ETC.AVCON / JSMArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014AIRPORT NOTES, ACCESS ROUTEAND STAGING NOTESIBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037CONFORMED SET21
RED CLEVELAND BLVDAIRLINE AVENUEHANGER ROADGENERATORDCOMPACTORTPHASE 1STAGING AREAPHASE 1PROPOSED LOADING DOCKPHASE 1PROPOSED WATER LINEINSTALLATIONPHASE 1PROPOSED CANOPYBUILDING ADDITIONPHASE 1PROPOSED PARKINGGARAGE ENTRANCEPHASE 1PROPOSEDLANDSCAPINGAROUND PONDPHASE 1PROPOSEDLANDSCAPINGPHASE IPARKING GARAGE ACCESSPHASE 1PROPOSEDLANDSCAPINGPHASE 1PROPOSEDLANDSCAPINGPHASE 1PROPOSEDLANDSCAPINGArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SAFETY DURING CONSTRUCTION PLANACCESS ROUTE & STAGING PLANEPHASE 1IBDRBJDOJDO1" = 50'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037N0Graphic Scale in Feet50501001. AIRPORT OPERATIONS - THE CONTRACTOR SHALL ACQUAINT HIS/HERSUPERVISORS AND EMPLOYEES WITH THE AIRPORT ACTIVITIES ANDOPERATIONS THAT ARE INHERENT AT THIS AIRPORT AND SHALL CONDUCTHIS/HER CONSTRUCTION ACTIVITIES TO CONFORM TO ALL ROUTINE ANDEMERGENCY AIR TRAFFIC REQUIREMENTS AND GUIDELINES ON SAFETYSPECIFIED IN PARAGRAPH 10 BELOW.2. VEHICLE IDENTIFICATION - ALL CONTRACTOR VEHICLES THAT ARE AUTHORIZEDTO OPERATE ON THE AIRPORT OUTSIDE OF THE DESIGNATED CONSTRUCTIONAREA LIMITS OR HAUL ROUTES, AS SPECIFIED ON THE PLANS AND WITHIN THEACTIVE AIRCRAFT OPERATIONS AREA (AOA) SHALL DISPLAY IN FULL VIEWCOMPANY DECALS, NOT LESS THAN 6 INCH "LETTERS" AND AIRPORT PERMITDECAL. THESE VEHICLES SHALL ALSO BE BE EQUIPPED WITH A FLASHINGAMBER (YELLOW) DOME-TYPE LIGHT MOUNTED, (360° ROTATING) ON TOP OFTHE VEHICLE AND OF SUCH INTENSITY TO CONFORM TO LOCAL CODES FORMAINTENANCE AND EMERGENCY VEHICLES.3. ROADWAY PAVEMENT CLOSURES - A MINIMUM OF 72 HOURS NOTICE OFREQUESTED CLOSING SHALL BE DIRECTED TO THE RPR, WHO WILLCOORDINATE THE REQUEST WITH AIRPORT OPERATIONS. SAA WILL GRANT ORDENY REQUEST BASED ON SCHEDULED TRAFFIC.4. TRENCH MARKING - OPEN TRENCHES, EXCAVATIONS AND STOCKPILEDMATERIALS SHALL BE PROMINENTLY MARKED WITH BARRICADES EQUIPPEDWITH FLAGS AND LIGHTED BY APPROVED LIGHT UNITS DURING HOURS OFRESTRICTED VISIBILITY AND DARKNESS.5. OPEN FLAME - OPEN FLAME, WELDING OR TORCH CUTTING OPERATIONS AREPROHIBITED UNLESS ADEQUATE FIRE AND SAFETY PRECAUTIONS HAVE BEENTAKEN AND THE PROCEDURE APPROVED BY AIRPORT OPERATIONS AND THEENGINEER.6. STOCKPILE EROSION AND DUST CONTROL - STOCKPILED MATERIAL AND OPENEXCAVATIONS SHALL BE TREATED IN SUCH A MANNER AS TO PREVENTMOVEMENT RESULTING FROM AIRCRAFT BLAST OR WIND CONDITIONS. (SEESPECIAL PROVISIONS FOR ADDITIONAL REQUIREMENTS).7. DEBRIS CONTROL - "FOREIGN OBJECT DEBRIS" WASTE AND LOOSE MATERIALSHALL NOT BE ALLOWED ON ACTIVE AIRCRAFT MOVEMENT AREAS OR WITHINTHE SAFETY AREAS. IF OBSERVED TO BE ON ACTIVE AIRCRAFT MOVEMENTAREAS OR WITHIN THE SAFETY AREA, THE MATERIAL WILL BE REMOVEDIMMEDIATELY BY THE CONTRACTOR. THE ENGINEER MAY DIRECT THAT DEBRISPROBLEMS DURING CONSTRUCTION NOT CORRECTED BY THE CONTRACTORBE CORRECTED BY OTHERS AT THE EXPENSE OF THE CONTRACTOR.8. SAFETY GUIDELINES, AND FAA ADVISORY CIRCULAR (LATEST EDITIONS):150/5200-18 "AIRPORT SAFETY SELF INSPECTION"150/5370-2 "OPERATIONAL SAFETY ON AIRPORTS DURING CONSTRUCTION"FAA PART 77 "OBJECTS AFFECTING NAVIGABLE AIRSPACE"ORLANDO SANFORD INTERNATIONAL AIRPORT - IDENTIFICATION BADGEPROCEDURESORLANDO SANFORD INTERNATIONAL AIRPORT - RULES AND REGULATIONSORLANDO SANFORD INTERNATIONAL AIRPORT - AIRPORT CERTIFICATIONMANUALORLANDO SANFORD INTERNATIONAL AIRPORT - AIRPORT SECURITY PLAN9. CONTRACTOR IS REQUIRED TO HAVE A PERSON ON CALL 24-HOURS A DAY FOREMERGENCY MAINTENANCE. CONTRACTOR MUST FILE THE CONTACT PERSON'SNAME WITH SAA OPERATIONS.10. CONTRACTOR IS RESPONSIBLE OF ENSURING ALL MOTOR VEHICLEOPERATORS (PRIVATE OR CONTRACTOR) HAVE THE APPROPRIATE VEHICLEINSURANCE AND TO ENSURE ALL OPERATORS HAVE CURRENT & VALIDDRIVERS LICENSES (CURRENT ISSUE) ON THEIR PERSON.11. CONTRACTOR SHALL PROVIDE AN EMERGENCY NOTIFICATION LIST (24-HOURCONTACT LIST) WHICH IDENTIFIES THE SUPERINTENDENT AND ALLSUBCONTRACTOR SUPERVISORS/LEADS.12. THE CONTRACTOR IS REQUIRED TO COMPLY WITH THE REQUIREMENTS OFCONFINED SPACE ENTRY (OSHA 29 CFR 1910.146).13. THE CONTRACTOR SHALL COMPLY WITH THE SAA MAINTENANCE DEPARTMENTLOCK-OUT/TAG-OUT PROCEDURE AND WITH NFPA 70E.SAFETY NOTESMATCH LINE A - SEE MATCH LINE A RIGHTMATCH LINE A - SEE MATCH LINE A LEFTCONFORMED SET22
RESTRIC
T
ED AR
EAKEEP OU
T
REST
R
IC
TE
D
A
R
EAKEEP O
U
T
RESTR
I
CT
ED
AR
E
A
KEEP
OU
T
RESTR
I
CT
ED
AR
EA
KEEP
OUTRESTRI
CT
E
D
A
REA
KEEP
OU
T
RESTR
I
CT
ED
AR
EA
KEEP
OU
T
RESTR
I
CT
ED
AR
EA
KEEP
OU
T
REST
R
IC
T
ED
A
R
EAKEEP O
U
TRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUT RESTRICTED AREA KEEP OUT RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUT RESTRICTED AREAKEEP OUT RESTRICTED AREA KEEP OUTRESTRICTED AREA KEEP OUT RESTRICTED AREAKEEP OUTRESTRICTED AREA KEEP OUT
RESTRI
C
T
E
D AREA
KEEP OUTRESTRICTED AR
EA
KEEP OUTRESTRICTED AREA KEEP OUTRESTRICT
ED AREA KEEP OUT SITE BENCHMARK # 2SITE BENCHMARK # 1SITE BENCHMARK # 3SITE BENCHMARK # 4GEN
E
R
A
T
O
R
DCOMPACTORTCD1.00 - DEMOLITION PLAN PHASE 1C1.00 - SITE DIMENSION PLAN PHASE 1C1.03 - SITE GRADING PLAN PHASE 1C1.06 - SITE UTILITY PLAN PHASE 1C1.08 - SIGNAGE AND STRIPING PLAN PHASE 1C1.14 - STORMWATER POLLUTION PREVENTION PLAN PHASE 1CD1.01 - DEMOLITION PLAN PHASE 1C1.07 - SITE UTILITY PLAN PHASE 1SEE PLANS BY AVCONAIRLINE AVENUERED CLEVELAND BOULEVARDHANGER ROADCD1.02 - DEMOLITION PLAN PHASE 1C1.01 - SITE DIMENSION PLAN PHASE 1C1.04 - SITE GRADING PLAN PHASE 1C1.09 - SIGNAGE AND STRIPING PLAN PHASE 1C1.15 - STORMWATER POLLUTION PREVENTION PLAN PHASE 1CD1.03 - DEMOLITION PLAN PHASE 1C1.02 - SITE DIMENSION PLAN PHASE 1C1.05 - SITE GRADING PLAN PHASE 1C1.10 - SIGNAGE AND STRIPING PLAN PHASE 1C1.16 - STORMWATER POLLUTION PREVENTION PLAN PHASE 1C1.11 - TURN LANE DESIGN PLAN AT INTERSECTION OF E. AIRPORT BLVD. AND RED CLEVELAND BLVD.(LTO)(S)(SVO)(ST)(SVO)(ST)Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SHEET LAYOUT PLANPHASE 1IBDRBJDOJDO1" = 100'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037N0Graphic Scale in Feet100100200CONFORMED SET23
GENERATORTRASHCOMPACTORCHILLERTRANSFORMERTRANSFORMERCHILLERGENERATORDCOMPACTORTN: 1615165.85E: 579015.34N: 1615153.19E: 578968.82N: 1615050.50E: 578969.82N: 1614988.62E: 579012.89EXISTING PARKINGGARAGE WEST SIDEEXISTING AIRPORT TERMINALEXISTING BUILDINGEXISTING PARKINGRED CLEVELAND BOULEVARDRED CLEVELAND BOULEVARDAIRPORT AVENUEHANGER ROADDESIGN BY AVCONPROP. LANDSCAPED AREAPRO
P
O
SE
D
LOADI
N
G
D
O
C
K
BUIL
DI
N
G RED CLEVELAND BOULEVARDLOADINGDOCKEXISTING AIRPORT TERMINALRED CLEVELAND BOULEVARDEXISTINGAIRPORTTERMINALPROPOSED RAMPPHASE 3TURN LANEIMPROVEMENTSPHASE 1PROPOSEDLANDSCAPED AREAEXISTINGTICKET CANOPYEXISTINGTICKET CANOPYPROPOSEDGARAGE ACCESSPHASE 1PROPOSEDGARAGE ACCESSRE-STRIPEEXISTINGLANESBAGGAGE BELTPROPOSED BUILDINGNEW TICKETING AREAPHASE 2DROP-OFFAREASKYWAY ADDITIONPHASE 3SKYWAY ADDITIONPROPOSED DROP-OFF / PICK-UPPROPOSEDCANOPY RENOVATIONPHASE 2PROPOSEDPAVEMENTMODIFICATIONPROPOSED LANDSCAPED AREAPROPOSED BUILDING PHASE 3EXISTING LOADING DOCKPROPOSED PARKING LOTINGRESS / EGRESSPHASE 1PROPOSEDSIDEWALK ANDPAVEMENT MODIFICATIONPROPOSEDSIDEWALK REMOVALPHASE 2PROPOSEDLIFT STATIONArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014PROJECT OVERVIEWALL PHASESIBDRBJDOJDO1" = 80'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037N0Graphic Scale in Feet8080160CONFORMED SET24
DCOMPACTORTEXISTING PARKINGGARAGE WEST SIDEEXISTING AIRPORT TERMINALEXISTING BUILDINGRED CLEVELAND BOULEVARDAIRPORT AVENUEHANGER ROADRED CLEVELAND BOULEVARDEXISTING AIRPORT TERMINALRED CLEVELAND BOULEVARDEXISTING TICKETCANOPY MODIFICATIONEXISTINGTICKET CANOPY(TO REMAIN)PROPOSEDGARAGE ACCESSPROPOSEDGARAGE ACCESSRE-STRIPEEXISTINGLANESEXISTING LOADING DOCKLOADING DOCK BUILDINGPHASE 1PROPOSEDPOND MODIFICATIONPROPOSED PAVEMENT MODIFICATIONAND PARKING RE-STRIPINGLOADINGDOCKPROPOSEDTURN LANESIDE WALKTRAFFICSIGNALArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014OVERVIEWPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037N0Graphic Scale in Feet8080160CONFORMED SET25
N
O
P
AR
K
IN
G
FI
R
E
LA
N
E
NDING
O
R
STA
RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTSITE BENCHMARK # 2SITE BENCHMARK # 1N
O
P
AR
K
IN
G
FI
R
E
LA
N
E
NDING
O
R
STA EXISTING PARKING GARAGE - WEST SIDEEXISTING CHECK-IN AREAREMOVE AND REPLACECURB AND PAVEMENTFOR UTILITY EXTENSIONSAW-CUT EXISTING PAVEMENTAND REMOVE CURB AND GUTTER PHASE 1BOLLARDS TO BEREMOVED WITH PHASE 1BOLLARDS TO BEREMOVED WITH PHASE 1 (TYP.)EXISTING BOLLARDSTO BE REMOVED (TYP.)INSTALL 8" LINE STOPAND REMOVE EXISTINGWATER MAIN TO NORTHREMOVEBOLLARDS TYP.REMOVE CURBREMOVE NO PARKING STRIPINGREMOVE NO PARKING STRIPINGREMOVE SIGNBEGIN BOLLARD REMOVALRELOCATE EXISTINGTRASH COMPACTORREMOVE CURBPAVEMENT TO BE REMOVEDREMOVE WATER PIPESEE C1.06 FORRELOCATION LIMITSREMOVEBOLLARDS(TYP.)CURB TO BE REMOVEDREMOVE LIGHT POLEREUSE FIXTUREON NEW POLEREMOVE SANITARYSEWER MANHOLEREMOVE SIGNREMOVE TREECURB TO BE REMOVEDREMOVE WHEEL STOPSCURB TO BE REMOVEDREMOVE TREEBEGIN CURB REMOVALREMOVEBOLLARDS TYP.REMOVE GATE,EQUIPMENTAND BOLLARDSEXISTING CURBTO REMAINREMOVE DUMPSTERAND CONCRETEREMOVE SANITARY LINEREMOVE SIGNSREMOVE STEEL COLUMNAND FOUNDATIONPROTECT EXISTINGSTORM INLETSAW-CUT EXISTING PAVEMENTSAW-CUT PAVEMENTAND REMOVE CURBSAW-CUT EXISTINGPAVEMENT AND REMOVECURB AND GUTTER PHASE 1EXISTING LIGHT POLE TO REMAIN(TERMINATE CIRCUITRY)REMOVE LIGHT POLEREUSE FIXTUREON NEW POLEREMOVE LIGHT POLEREUSE FIXTUREON NEW POLEREMOVE FIRE HYDRANTREMOVE RADIUS IN STRIPEINSTALL 8" LINESTOP AND REMOVEWATER MAIN TO SOUTHREMOVE INLETREMOVE EXIST. 10" STORM PIPEPROTECT INLETPLUG EXIST. 10" F.L.SAVE AND PROTECTGREASE TRAPSREMOVE WALLPROTECT BACKFLOWPROTECT FIRE HYDRANTEXISTING 8" STORMPIPE TO REMAINCURB TO BE REMOVEDSIGNS TO BE REMOVEDREMOVE POWERPOLE AND PULL BOXREMOVE WHEEL STOPSSIGN TO BE REMOVED TYP.REMOVE PULL BOXESREMOVE TREEREMOVE VEGETATIONREMOVE CONCRETE,METAL STRUCTURE,BOLLARDS AND BENCHESREMOVE TREEREMOVE CURBAND PAVEMENTREMOVE ELECTRIC BOXFENCE TO BE REMOVEDREMOVE EXISTING 8" PVCSTORM DRAIN AND CLEANOUTFROM MECHANICAL ROOMTO LOCATION SHOWNEXISTING 6" PVC STORMDRAIN TO REMAINEXISTING CLEANOUTREMOVE FENCE AND BOLLARDSREMOVED / REUSEEXISTING STAIRCASEEXISTING LIGHTPOLE TO REMAINEXISTING CLEANOUT (TO REMAIN)REMOVE EXISTING 6" PVCTO LOCATION SHOWNREMOVE FIRE HYDRANTAND WATER MAINREMOVE SHRUBSREMOVE ELECTRIC LINEMATCH LINE CD1.01N0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014DEMOLITION PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037NOTES:1. PROPOSED WATER MAIN IS REQUIRED TO BE INSTALLED ANDTESTED AND RELEASED PRIOR TO REMOVAL OF EXISTINGWATER MAIN. LINE STOP OF THE EXISTING WATER MAIN ANDRECONNECTION OF THE NEW WATER MAIN SHALL BEPREFORMED SIMULTANEOUS OR AS CLOSE AS POSSIBLE SOTHAT DOWN TIME OF THE WATER SERVICE IS LIMITED.2. THIS PLAN SHOWS ALL LARGE TREES TO BE REMOVED. AREASWITH LANDSCAPING IN CONFLICT WITH PROPOSEDCONSTRUCTION AND LANDSCAPING MAY NOT BE DEPICTED, BUTARE REQUIRED TO BE REMOVED.3. CONTRACTOR SHALL MAINTAIN TRUCK ACCESS FROM EASTERNLOADING DOCK UNTIL NEW LOADING DOCK IS CONSTRUCTED.LEGENDKEY MAPMATCH LINEPHASE I SAW-CUT LIMITSSAW-CUTSIGN TO BE REMOVEDTREE TO BE REMOVEDAREA TO BE DEMOLISHEDPAVEMENT TO BE REMOVEDCONFORMED SET26
EXISTING TERMINAL(SEE ARCHITECTURAL PLAN)EXISTING CANOPY TO REMAINPHASE IOPEN CUT AND REPAIRFOR UTILITY EXTENSIONPROTECT EXISTING COLUMNREMOVE METAL STAIRCASEPARTIAL CANOPYDEMOLITION10.00'REMOVE BOLLARDSRELOCATED AC UNITS / TRANSFORMERSSEE STRUCTURAL FOR CONCRETEDEMO / INSTALLATION FOR COLUMNSMATCH LINE CD1.00N0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014DEMOLITION PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037KEY MAPLEGENDMATCH LINEPHASE I SAW-CUT LIMITSSAW-CUTSIGN TO BE REMOVEDTREE TO BE REMOVEDAREA TO BE DEMOLISHEDPAVEMENT TO BE REMOVEDCONFORMED SET27
SITE BENCHMARK # 5STRIPING AND CURBTO BE REMOVEDSTRIPING TOBE REMOVEDSTRIPING AND CURBTO BE REMOVEDPAVEMENT, STRIPINGAND CURB TO BE REMOVEDSAWCUT EDGE OF PAVEMENTAND REMOVE STRIPING AND CURBSAW-CUT EXISTINGFLUME AND REMOVEREMOVE MITEREDEND SECTIONSREMOVE CURB INLET TOP.MANHOLE TO REMAIN.SAW-CUT ROADSAT EXISTINGCONCRETE ISLANDSAW-CUT ROADSAT EXISTINGCONCRETE ISLANDSAW-CUT AND REMOVEMODULAR BUILDING ANDEXISTING CONCRETERELOCATE BOXAND LIGHT POLEMANHOLE TOP TO BE RAISEDMANHOLE TO REMAINREMOVE STOP SIGN ANDLEFT TURN ONLY SIGNEXISTINGPARKING GARAGEWEST SIDEREMOVE FLUMEREMOVE MITEREDEND SECTIONSN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014DEMOLITION PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037KEY MAPLEGENDMATCH LINESAW-CUTSIGN TO BE REMOVEDAREA TO BE DEMOLISHEDPAVEMENT TO BE REMOVEDCONFORMED SET28
SAW-CUT PAVEMENT ANDREMOVE CONCRETE ISLANDSAW-CUT PAVEMENT ANDREMOVE CONCRETE ISLANDBEGIN CURB ANDPAVEMENT REMOVALSAW-CUT PAVEMENTAND REMOVE CURBDIRECTIONAL ARROWSTO BE REMOVEDDIRECTIONAL ARROWSTO BE REMOVEDSTRIPING TO BE REMOVEDSTOP BAR TOBE REMOVEDEXISTING CURB TO REMAINEXISTING FLUME TO REMAINREMOVE EXISTINGSTOP SIGNEXISTING CONCRETEVALLEY GUTTERREMOVE STOP BARPAVEMENT MARKINGTO BE REMOVEDPAVEMENT MARKINGTO BE REMOVEDREMOVE GATEREMOVEJERSEYBARRIERSAW-CUT AND REMOVE PAVEMENT2.00'N0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014DEMOLITION PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037KEY MAPLEGENDMATCH LINESAW-CUTSIGN TO BE REMOVEDAREA TO BE DEMOLISHEDPAVEMENT TO BE REMOVEDSTRIPING TO BE REMOVED (TYP.)STRIPING TO REMAIN (TYP.)WHEEL STOPS TO REMAIN (TYP.)STRIPING TO BE REMOVED (TYP.)STRIPING TO BE REMOVED (TYP.)CONFORMED SET29
RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTSITE BENCHMARK # 2SITE BENCHMARK # 1GENERATORDCOMPACTORTTRUCK TURN-AROUNDLOA
DI
N
G
D
O
C
K
B
UI
L
DI
N
G
(SEE
A
R
C
HIT
E
C
T
U
R
A
L
PL
A
N)40'40'110'EXISTINGLOADING DOCKS RAMPAIRLINE AVENUEHANGER ROAD(HC)EXISTING PARKING GARAGE - WEST SIDEN: 1614669.27E: 577295.00N: 1614591.94E: 577192.54N: 1614704.90E: 577330.45N: 1614732.83E: 577358.38N: 1614531.05E: 577325.91N: 1614655.40E: 577435.81N: 1614627.47E: 577407.882'RN: 1614602.43E: 577364.605'RDOOR TYP.ROLLING DOOR TYP.LOADING DOCKRAMPEXISTING TYPE "F"CURB AND GUTTER5'R4.5'R2'R3'RMATCH EXISTING PAVEMENTMATCHEXISTINGPAVEMENTPROPOSED SCREEN WALLSEE ARCHITECTURALPLANS FOR DETAILS226642522.67'14.66'19.09'6.00'10.00'12.00'15.00'18.00'MATCH EXISTINGCURB AND PAVEMENTMATCH EXISTINGCURB AND PAVEMENT6.00'18.00'10.00'18.00'20.00'20.00'6.00'10.00'50'R5MATCH EXISTINGCURB AND PAVEMENTN: 1614532.91E: 577251.08N: 1614562.95E: 577324.30N: 1614607.54E: 577381.245.00'7PROPOSED SCREEN WALLSEE ARCHITECTURALPLANS FOR DETAILS7EXTEND 6' AOA FENCE87MATCH EXISTING22MATCH EXISTINGPAVEMENT AND CURBTEMPORARY FENCEFOR PHASE 276TRASH COMPACTOR LOCATION19.68'DOUBLE CORRAL GATE624RELOCATED STAIRCASEN: 1614871.64E: 577539.13N: 1614855.79E: 577523.31PROPOSED SERVICE ELEVATOR7.79'TEMPORARYSTABILIZED GRADEMATCH EXISTINGPAVEMENT AND CURB1.F1.FC1.19C1.193332'RN: 1614679.66E: 577429.70N: 1614664.49E: 577444.85N: 1614621.84E: 577300.81N: 1614617.55E: 577305.0114.50'1.G1.GC1.19C1.1910.00'24.00'TEMPORARY FENCEFOR PHASE 211PROPOSED TRANSFORMERPROPOSEDDUMPSTERKey Mapwww.sunshine811.comN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SITE DIMENSION PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037(HC)71234567KEYNOTES SYMBOL LEGENDTEMPORARY HEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18TYPE 'D' CONCRETE CURB FDOT INDEX NO. 300SEE DETAIL 1.9, SHEET C1.18TYPE 'F' CONCRETE CURB FDOT INDEX NO. 300SEE DETAIL 1.10, SHEET C1.18INTEGRAL CONCRETE SIDEWALKSEE DETAIL 1.7, SHEET C1.18TEMPORARY HC ACCESSIBLE RAMPWITH DETECTABLE WARNING PAD,PER FDOT INDEX 304 CR-EPROP. MODIFIED TYPE "D" CONCRETE CURB,SEE DETAIL 1.9, SHEET C1.18NOSE DOWN CURBSEE DETAIL 1.17, SHEET C1.18LEGEND8PROPOSED MIAMI CURBSEE DETAIL 1.28, SHEET C1.18MATCH LINESTABILIZED GRADESAW-CUTREFERENCE BASELINEHANDICAP PARKING SIGNSEE DETAIL 1.23, SHEET C1.18PARKING SPACES PER ROWHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18SIDEWALKSEE DETAIL 1.14, SHEET C1.18CONCRETEBOLLARDSEE SHEET C1.13NOTE:STABILIZATION SHOWN IS A DEPICTION OF THE AREA BEINGPREPARED FOR PHASE 2 CONSTRUCTION. CONTRACTOR SHALLMAINTAIN ACCESS TO EXISTING LOADING DOCK UNTIL NEW LOADINGDOCK IS OPERATIONAL.CONFORMED SET30
111(DNE)(DNE)(DNE)(DNE)(S)(S)EXPANDED POND16.00'25.00'N: 1614196.37E: 577584.26N: 1614037.46E: 577090.2712.58'12.62'TO EOPEXISTING TICKET BOOTH10.0'R38.0'R50.0'R62.0'R50.0'R2.0'R15.0'R30.0'R5.0'R25.0'R25.0'RRELOCATED POLEPROPOSED SIGN #1"GARAGE PARKINGTERMINAL DELIVERIES"SVC ONLY4466315.0'R15.0'R12.00'9.61'12.00'12.00'5.00'12.00'12.00'119GATE(SEE SP 21)PROPOSED CONCRETE FLUMESEE DETAIL 1.26, SHEET C1.1950.00'10.00'6.00'684.00'4.00'10.00'50.00'8PROPOSED CONCRETE FLUMESEE DETAIL 1.26, SHEET C1.196EXISTING CURB474.00'EXISTING CONCRETE FLUME4N: 1614246.67E: 577513.72N: 1614069.00E: 577144.917N: 1614104.93E: 577144.6475.0'R5.0'R444PROPOSED MESPROPOSED CONCRETE FLUMESEE DETAIL 1.26, SHEET C1.19PROPOSED INLET TOPPROPOSED TYPE 'H' INLETPROPOSED MES49.66'15.00'(LTO)(S)(SVO)(ST)(SVO)1.H1.HC1.19C1.191.I1.IC1.19C1.19N: 1614087.00E: 577162.90N: 1614087.00E: 577098.02N: 1614233.88E: 577139.85N: 1614265.81E: 577139.235'R64.20'2.5'R37'R2.5'R10.36'N: 1614278.99E: 577167.43N: 1614278.87E: 577186.94N: 1614261.95E: 577182.65N: 1614265.10E: 577218.50N: 1614266.14E: 577389.17N: 1614262.68E: 577449.18N: 1614250.15E: 577397.96N: 1614215.87E: 577449.03N: 1614196.42E: 577488.60N: 1614208.41E: 577507.66N: 1614223.18E: 577516.4511'R4.00'RELOCATEDPULL BOX(Y)www.sunshine811.comN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SITE DIMENSION PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 6503791234567NO LEFT TURNSEE DETAIL 1.22, SHEET C1.19DO NOT ENTERSEE DETAIL 1.21, SHEET C1.19STOP SIGN, R1-1 24" X 24"SEE DETAIL 1.23, SHEET C1.19MATCH LINECONCRETEHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18PARKING SPACES PER ROWREFERENCE BASELINE(NLT)(DNE)(S)LEGENDLIGHT DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.12, SHEET C1.18HEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18TYPE 'D' CONCRETE CURB INDEX NO. 300SEE DETAIL 1.9, SHEET C1.18TYPE 'F' CONCRETE CURB INDEX NO. 300SEE DETAIL 1.10, SHEET C1.18TURNDOWN CONCRETE SIDEWALKSEE DETAIL 1.14, SHEET C1.18TYPE I CONCRETE ISLAND PER FDOT INDEX NO. 302MATCH EXISTING CURBKEY MAPKEYNOTES SYMBOL LEGEND891050' TRANSITION TO 12' LANECONCRETE VALLEY GUTTER PER FDOT INDEX NO. 300SEE DETAIL 1.29, SHEET C1.18TRANSITION FROM 'F' CURB TO 'D' CURB11NOSE DOWN CURBSEE DETAIL C1.12, SHEET C1.18CONFORMED SET31
AIRLINE AVENUEEXISTING PARKING LOTEXISTING PARKING LOTEXISTING TICKET BOOTH(TO REMAIN)PROPOSED SIGN #3"GARAGE PARKINGECONOMY PARKING"6133214.00'28.92'3.25'11.17'25.67'4.00'10.00'20.00'4.00'14.00'60°13.33'16.50'N: 1613461.76E: 577257.174.00'3'RN: 1613487.22E: 577186.823'RN: 1613462.69E: 577187.05N: 1613459.18E: 577135.82www.sunshine811.com2' WIDE TYPE II CONCRETE TRAFFIC SEPARATORMODIFIED FDOT INDEX NO. 302N0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SITE DIMENSION PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 650379123456KEYNOTES SYMBOL LEGENDLEGENDMATCH LINECONCRETEHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18PARKING SPACES PER ROWREFERENCE BASELINEKEY MAPTYPE 'F' CONCRETE CURB INDEX NO. 300SEE DETAIL 1.10, SHEET C1.18MATCH EXISTING TYPE 'F' CURBNEW GATESSEE ARCHITECTURAL PLANSTYPE I CONCRETE ISLAND PER FDOT INDEX 3026" CONCRETE PAVEMENTSEE DETAIL 1.13, SHEET C1.18SIDEWALKSEE DETAIL 1.14, SHEET C1.187TYPE 'F' CONCRETE CURB INDEX NO. 300WITH 2' CURB CUT AT LOW POINTSSEE DETAIL 1.10, SHEET C1.18CONFORMED SET32
RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTSITE BENCHMARK # 2SITE BENCHMARK # 1GENERATORDCOMPACTORTEXISTINGPARKING GARAGEWEST SIDELOADING DOCKBUILDINGFFE = 51EXISTING CHECK-IN AREATC 50.50BC 49.8051.0051.4550.95TC 50.50BC 49.50PROPOSED MODIFIEDTYPE "D" CURB FOR PHASE 149.5050.6051.00TC 50.50BC 49.5050.10±51.0051.0050.4550.4050.3550.8550.3550.1550.8550.35M.E. 49.80±50.2550.0050.5050.0049.5049.0048.5048.45 M.E.48.45 M.E.48.9548.4549.50 M.E.EXISTING GRATE48.5150.3049.8050.00 M.E.MATCH EDGE OFEXISTING PAVEMENT50.80 TW47.25M.E.M.E. 49.04M.E. 49.42±48.92±M.E. 48.97±M.E. 49.32±48.82±M.E. 48.93M.E.48.85±49.4049.3551.4050.9050.4051.3550.8550.8550.3550.7050.2050.5050.0050.3049.8050.2049.7049.8049.3049.7549.3049.6050.3049.8049.8050.5050.0050.7050.2050.0050.0049.50M.E. 49.70±M.E. 49.25±45° BEND50.8050.3050.8050.30M.E. 50.00±50.80 TW47.2550.3650.66±50.16±M.E. 48.80M.E. 48.86±M.E. 49.28±49.1049.2549.2549.00M.E. 49.5649.0648.9049.9049.8549.00±51.5051.0048.9049.1049.5049.00RELOCATED STAIRCASEPROPOSED SERVICE ELEVATORSTABILIZED GRADEM.E. 48.95±M.E. 49.33±48.83±1.F1.FC1.19C1.1950.8050.3051.3050.8050.0050.3050.5050.5050.0050.0050.3048.5849.7050.0050.2051.0051.0050.7050.9550.3050.5050.501.G1.GC1.19C1.19EXISTING CLEANOUTS-14S-15S-18S-17S-16S-4S-13S-12S-11S-10S-9S-8S-7S-6S-5S-1S-2S-3S-19S-20www.sunshine811.comN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SITE GRADING PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037S-1S-2S-3S-4S-5S-6S-7S-8S-9S-10S-11S-12S-13TRENCH DRAIN AND SUMP PUMP(SEE ARCHITECTURAL DRAWINGSFOR DESIGN INFORMATION)TOP GRATE = 47.00STORM STRUCTURE SCHEDULEKEY MAPLEGEND47.5347.11MATCH LINESAW-CUT LIMITSCHAIN LINK FENCEPROPOSED SPOT ELEVATIONEXISTING SPOT ELEVATIONPROPOSED STORM SEWER SYSTEMPROPOSED MITERED END SECTIONPROPOSED FLOW LINEEXISTING CONTOUR LINE110 LF~ 2" PVC FORCE MAINCORE BORE EXISTING INLETAND CONNECT @ EL. 46.00RAISE INLET AND GRATETO ELEV. 49.106" CLEANOUT W/ 6" WYETOP ELEV. 50.90FL. 47.0035 LF. ~ 6" PVC @ 1.0%6" INLINE CLEANOUTTOP ELEV. 50.90FL. 46.6515 LF. ~ 6" PVC @ 1.0%CONNECT TO EXIST. 30" RCPPER FDOT INDEX 280FL. 46.5020 LF. ~ 6" PVC @ 1.0%6" CLEANOUT W/ 6" WYETOP EL. 50.90FL. 46.7040 LF. ~ 6" PVC @ 1.0%6" CLEANOUT W/ 6" WYETOP ELEV. 51.30FL. 47.10STABILIZED GRADEHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18SIDEWALKSEE DETAIL 1.14, SHEET C1.18CONCRETE ISLANDS-146" CLEANOUT WITH 6" WYETOP ELEV. 51.00±CONNECT 5± LF ~ 6" PVCTO EXISTING CLEANOUT W/ 6" WYE.FL 41.50±S-1525 LF ~ 6" PVC @ 1.0%S-166" CLEANOUT WITH 6" WYEFL. 41.20S-1710 LF ~ 6" PVC @ 1.0%S-186" CLEANOUT WITH 6" WYE @ 1.0%CONNECT TO EXISTING 6" PVCFL. 41.10±S-19M.H. WITH 2" GRINDER SUMP PUMPOR PACKAGED LIFT STATIONS-206 LF~ 6" PVCCONFORMED SET33
(LTO)(S)(SVO)(ST)(SVO)1.H1.HC1.19C1.191.I1.IC1.19C1.1930" RCP WITH 30" M.E.S.49.60 M.E.50.03 M.E.49.59 M.E.50.5050.0050.2049.75 M.E.50.32 M.E.49.85 M.E.50.5050.0049.49 M.E.49.39 M.E.50.21M.E. 49.7150.0849.5849.9549.4549.80M.E. 49.30±49.8049.3049.74M.E. 49.2449.7349.2349.5749.0749.5249.0249.6549.1549.67M.E. 49.1749.5049.0049.2548.7549.0048.5049.2548.7548.5049.2048.70 M.E.48.2550.0049.5050.2549.7549.7549.2550.5550.0550.3049.8050.8550.3550.6050.1050.5550.0550.3049.8050.0049.5050.9850.48 M.E.50.7150.21 M.E.M.E. 49.92±M.E. 49.61±49.75M.E. 49.2549.33M.E. 48.8350.0049.50M.E. 49.71M.E. 49.81M.E. 49.76M.E. 49.7049.4850.0549.5549.2050.0249.5250.0749.5749.9549.4549.8049.3049.6549.1549.0050.1049.601411871356241315946.50Key Mapwww.sunshine811.comN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SITE GRADING PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 6503746.3447.5347.11MATCH LINESAW-CUT LIMITSCHAIN LINK FENCEPROPOSED SPOT ELEVATIONEXISTING SPOT ELEVATIONPROPOSED STORM SEWER SYSTEMPROPOSED MITERED END SECTIONPROPOSED FLOW LINESEXISTING CONTOUR LINELEGENDCONNECT 20 LF 45" X 29"ERCP @ 0.24%± TO EXIST. PIPEFDOT TYPE "H" INLET (4 GRATES)TOP ELEV. 50.00SW. FL. 46.13 (45" X 29")SW. FL. 46.10 (25" X 24" ERCP)NE. FL. 46.10 (45" X 29" ERCP)10 LF~ 45" X 29" ERCP @ 0.48%±CONNECT TO EXIST. CORRUGATEDMETAL PIPE PER DOT INDEX 280FOR - PIPE CONNECTION40 LF~ 25" X 24" ERCP @ 1.0%CONCRETE MITERED END SECTION FL. 46.40CONCRETE MITERED END SECTION FL. 46.6052 LF~ 25" X 24" ERCP @ 0.66%CONNECT TO EXISTING STRUCTUREINV. ELEV. 46.94CONNECT 4-18" X 12" ERCPTO EXIST. 17" X 13" ERCPPER FDOT INDEX 280FOR DISSIMILAR PIPESMAINTAIN EXIST. SLOPE @ 0.33%CONCRETE MITERED SIDEDRAIN (QUAD) PER FDOTINDEX 273 W/GRATE FL. 46.44±TYPE II INLETTOP PER FDOT INDEX 210EOP EL. 48.2511' CONCRETE FLUMESEE DETAIL 1.26, SHEET C1.195' CONCRETE FLUMESEE DETAIL 1.26, SHEET C1.19RAISE MANHOLE TOP TO ELEV. 49.00RAISE MANHOLE TOP TO ELEV. 50.20135781012142469111315STORM STRUCTURE SCHEDULEHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18CONCRETE ISLANDNOTE:CONTRACTOR TO VERIFY EXISTING PIPE SIZESPRIOR TO ORDERING NEW PIPE FOR EXTENSIONS.CONFORMED SET34
+0.50M.E.+0.50M.E.+0.50'M.E.+0.50'M.E.+0.50M.E.+0.50M.E.+0.50M.E.+0.50M.E.PROTECT EXISTING 15" PIPEwww.sunshine811.comN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SITE GRADING PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037LEGEND47.5347.11HEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18CONCRETEMATCH LINESAW-CUTPROPOSED SPOT ELEVATIONPROPOSED FLOW LINEEXISTING CONTOUR LINESIDEWALKSEE DETAIL 1.14, SHEET C1.18CONFORMED SET35
RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTSITE BENCHMARK # 2SITE BENCHMARK # 1GENERATORDCOMPACTORTTRUCKTURN-AROUNDEXISTINGPARKING GARAGEWEST SIDELOADING DOCKBUILDINGFFE = 51LOADINGDOCK RAMPCOURTYARDEXISTING8" WATERLINEEXISTING 6" SANITARY SEWEREXISTING 8" WATER MAINREMOVE ANDREPLACE CURBEXISTING UNDERGROUND ELECTRICOPEN CUT AND REPAIRREMOVE 8" LINE STOP AND INSTALLRESTRAINED 8" G.V. AND PLUG(SEE ARCHITECTURAL DRAWINGS)EXISTINGSTORMWATER INLETEXISTING ELECTRICREMOVE 8" LINE STOP ANDINSTALL RESTRAINED8" G.V. AND PLUGPROTECT EXISTING DOUBLEDETECTOR BACKFLOWEXISTING 8" WATER MAIN8771983161015421512345EXISTING FIRE HYDRANT6AIRLINE AVE.REDCLEVELANDBLVD.141213111726871920321181810229EXISTING FDCSEE NOTE 3 THIS SHEETEXISTING GAS TO BE RELOCATED BYGAS COMPANY AND MAKE ALL CONNECTIONSTO EXISTING AND PROPOSED GAS MAINS231110APPROX. LOCATION OF NEWPOWER CO. 5FTX10FTFP&L SPLICE BOX.APPROX. LOCATION OFNEW POWER CO. SWITCHN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SITE UTILITY PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037123451MATCH LINE C1.076782345678910111213141516171819CONNECT TO EXISTING 8" WATER MAIN WITH8" X 8" TAPPING SLEEVE AND VALVE8" PVC WATER MAIN8" - 22.5° BEND8" - 45° BEND8" - 90° BEND8" GATE VALVE8" X 6" TAPPING SLEEVE AND VALVEFIRE HYDRANT AND G.V. ASSEMBLYSEE DETAIL 1.34, SHEET C1.198" X 4" TAPPING SLEEVE AND VALVE4" FIRE LINEPOST INDICATOR VALVESEE DETAIL 1.33, SHEET C1.19BACKFLOW PREVENTERSEE DETAIL 1.30, SHEET C1.19FIRE DEPARTMENT CONNECTION4" - 90° BENDSEE ARCHITECTURAL DRAWINGSFOR CONNECTION TO BUILDING2" DOUBLE STRAP SERVICESADDLE AND CORPORATION STOP2" SERVICE LINE4" - 45° BENDMETER2" REDUCED PRESSURE BACKFLOW PREVENTERSEE DETAIL 1.31, SHEET C1.1920WATER LINE SCHEDULE SANITARY SEWER SCHEDULEKEY MAPNOTE:1. PROPOSED WATER MAIN IS REQUIRED TO BE INSTALLEDAND TESTED AND RELEASED PRIOR TO REMOVAL OFEXISTING WATER MAIN. LINE STOP OF THE EXISTING WATERMAIN AND RECONNECTION OF THE NEW WATER MAIN SHALLBE PREFORMED SIMULTANEOUS OR AS CLOSE AS POSSIBLESO THAT DOWN TIME OF THE WATER SERVICE IS LIMITED.2. BY-PASS PUMPING WILL BE REQUIRED DURING DEMOLITION,CONSTRUCTION AND TESTING OF THE SANITARY SEWER.3. CONTRACTOR TO VERIFY EXISTING WATER MAINCONNECTION FOR NEW FIRE HYDRANT ASSEMBLY IS OFFMAIN WATER MAIN AND NOT CONNECTED TO THE FIRE LINEMAIN IN THIS AREA.CONSTRUCT DOGHOUSE SANITARY MANHOLEAND CONNECT TO EXISTING 8" MAINS. INV. 45.10, N. INV. 45.25. TOP ELEV. 50.35220 LF ~ 8" PVC @ 0.40% CONCRETE ENCASEPER DETAIL 1.27, SHEET C1.19CONSTRUCT SANITARY MANHOLES. INV. 46.13, NE. INV. 46.20, TOP ELEV. 50.00±45 LF ~ 8" PVC @ 0.40%CONSTRUCT SANITARY MANHOLESW. INV. 46.38, N. INV. 47.80±,TOP ELEV. 51.10± (VERIFY AND CONNECTEXISTING GREASE INTERCEPTORS TOMANHOLE WITH A MIN OF 6" PVC.CONTRACTOR TO VERIFY INVS. UPSTREAMAND DOWNSTREAM CONNECTION POINTSPRIOR TO CONSTRUCTION. CONTRACTOR TOCONTACT ENGINEER WITH RESULTS.)8" X 4" SANITARY WYE, INV. 45.50±6 LF ~ 4" PVC @ 1.67%4" C.O. W/ WYE, INV. 45.60TOP ELEV. 50.7570 LF ~ 24" STEEL CASING WITH 0.25" WALLTHICKNESS. PROVIDE SPACERS. FIELD ANDSHOP WELDS OF CASING PIPE SHALL CONFORMTO AMERICAN WELDING SOCIETYSTANDARD SPECIFICATIONS.6" X 6" WYE - EXTENDED 10' - 6" PVC @ 1.0% MIN.6" CLEANOUT F.L. 42.50LEGENDCHAIN LINK FENCEPROPOSED WATER LINERPROPOSED ELECTRICAL LINE(SEE ELECTRICAL PLANS)EXISTING SANITARY SEWERPROPOSED SANITARY SEWEREXISTING UNDERGROUND ELECTRICEXISTING GAS MAINEXISTING WATER LINEPROPOSED STORM SEWER SYSTEMPROPOSED MITERED END SECTION4" - 22.5° BEND216" - 90° BEND229STABILIZED GRADEHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18SIDEWALKSEE DETAIL 1.14, SHEET C1.18CONCRETE2 1/2" SERVICE SADDLE AND 2 1/2" - 5' SERVICELINE PLUGGED FOR FUTURE CONNECTION231011CONFORMED SET36
COURTYARDEXISTING TERMINAL(SEE ARCHITECTURAL PLAN)APPROXIMATE LOCATION OFEXISTING 6" SANITARY SEWEREXISTING CANOPYREMOVE AND REPLACE CURBOPEN CUT AND REPAIREXISTING 8" WATERLINEREMOVE AND REPLACE CURBEXISTING STORM DRAINEXISTING FIREHYDRANT ASSEMBLY654313OPEN CUT SIDEWALKAND REPAIR7PROTECT EXISTING COLUMNRED CLEVELAND BLVD.28910EXISTING 6" PVCMATCH LINE C1.06N0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SITE UTILITY PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 650371234567WATER LINE SCHEDULEKEY MAP8" X 6" TAPPING SLEEVE AND VALVE6" PVC FIRE LINE6" 90° BENDPROPOSED 6" BACK FLOW PREVENTERSEE DETAIL 1.30, SHEET C1.19PROPOSED FDCSEE ARCHITECTURAL DRAWINGSFOR CONNECTION TO BUILDINGPOST INDICATOR VALVEWHEN INSTALLING UTILITIES REPAIR ROOF LEADERS AS NECESSARY.LEGENDCHAIN LINK FENCEPROPOSED WATER LINEREXISTING SANITARY SEWEREXISTING UNDERGROUND ELECTRICEXISTING GAS MAINEXISTING WATER LINEPROPOSED STORM SEWER SYSTEMPROPOSED MITERED END SECTION86" TEEHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18SIDEWALKSEE DETAIL 1.14, SHEET C1.1898" X 6" TAPPING SLEEVE AND VALVE10FIRE HYDRANT ASSEMBLYSEE DETAIL 1.34, SHEET C1.19CONFORMED SET37
RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTGENERATORDCOMPACTORTTRUCK TURN-AROUNDLOA
DI
N
G
D
O
C
K
B
UI
L
DI
N
G
(SEE
A
R
C
HIT
E
C
T
U
R
A
L
PL
A
N)40'40'110'EXISTINGLOADING DOCKS RAMPAIRLINE AVENUEHANGER ROAD(HC)EXISTING PARKING GARAGE - WEST SIDEROLLING DOOR TYP.LOADING DOCKRAMP23110'R444444TRASH COMPACTOR118'10'24'10'20'18'18'10'RELOCATED STAIRCASEPROPOSED SERVICE ELEVATORTEMPORARYSTABILIZED GRADE12'DUMPSTERTRANSFORMER10'Key Mapwww.sunshine811.comN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SIGNAGE AND STRIPINGPLAN PHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037(HC)71234KEYNOTES SYMBOL LEGEND4" WIDE SINGLE YELLOW PAVEMENT PARKING STRIPE TYP.5' WIDE ACCESSIBLE AISLE STRIPING PAINTEDON PAVEMENT, PER FDOT INDEX 17346SEE DETAIL 1.16, SHEET C1.18WHITE ACCESSIBLE SYMBOL PAINTED ONPAVEMENT, PER FDOT INDEX 17346SEE DETAIL 1.32, SHEET C1.18SYSL/4" SPACED @ 2' O.C. @ 45° BOUND BY SYSL/4"LEGENDSTABILIZED GRADEHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18SIDEWALKSEE DETAIL 1.14, SHEET C1.18CONCRETEMATCH LINESAW-CUTREFERENCE BASELINEHANDICAP PARKING SIGNSEE DETAIL 1.15, SHEET C1.18PARKING SPACES PER ROWCONFORMED SET38
(DNE)(DNE)(DNE)(DNE)(S)(S)EXPANDED PONDEXISTING TICKET BOOTHRELOCATED POLEPROPOSED SIGN #1"GARAGE PARKINGTERMINAL DELIVERIES"SVC ONLY115.0'RGATE(SEE ARCHITECTURALDRAWINGS FOR DETAILS)PROPOSED CONCRETE FLUMESEE DETAIL 1.26, SHEET C1.198PROPOSED CONCRETE FLUMESEE DETAIL 1.26, SHEET C1.19EXISTING CURBEXISTING CONCRETE FLUMEPROPOSED MESPROPOSED CONCRETE FLUMESEE DETAIL 1.26, SHEET C1.19PROPOSED INLET TOPPROPOSED TYPE 'H' INLETPROPOSED MES111111111112333(LTO)(S)(SVO)(ST)(SVO)1.H1.HC1.19C1.191.I1.IC1.19C1.192www.sunshine811.comN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SIGNAGE AND STRIPINGPLAN PHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 650379NO LEFT TURNSEE DETAIL 1.22, SHEET C1.19DO NOT ENTERSEE DETAIL 1.21, SHEET C1.19STOP SIGN, R1-1 24" X 24"SEE DETAIL 1.23, SHEET C1.19MATCH LINEPARKING SPACES PER ROWREFERENCE BASELINE(NLT)(DNE)(S)LEGENDKEY MAP123KEYNOTES SYMBOL LEGENDWHITE REFLECTIVE DIRECTIONAL ARROWS ON PAVEMENTPER FDOT INDEX NO. 17346. (TYP)SEE DETAIL 1.25, SHEET C1.196" DOUBLE SOLID YELLOW LINES24" WIDE SOLID WHITE PAINTED STOP BARPER FDOT INDEX NO. 17346 (TYP)SEE DETAIL 1.24, SHEET C1.19SERVICE VEHICLES ONLY(SVO)HEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18CONCRETECONFORMED SET39
AIRLINE AVENUEEXISTING PARKING LOTEXISTING PARKING LOTEXISTING TICKET BOOTH(TO REMAIN)PROPOSEDPARKING SIGN #2"ECONOMY PARKING"PROPOSED SIGN #3"GARAGE PARKINGECONOMY PARKING"10.00'20.00'
14.00'60°121334510.00'133www.sunshine811.comN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014SIGNAGE AND STRIPINGPLAN PHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 650379KEYNOTES SYMBOL LEGENDLEGENDMATCH LINEPARKING SPACES PER ROWREFERENCE BASELINEKEY MAP14" WIDE SINGLE WHITE PAVEMENT PARKING STRIPE (TYP)2SYSL/4", 2' O.C. @ 45° BOUND BY SYSL/4"3WHITE REFLECTIVE DIRECTIONAL ARROWS ON PAVEMENTPER FDOT INDEX NO. 17346 (TYP)SEE DETAIL 1.25, SHEET C1.1946" SKIP WHITE LANE DELINEATION LINEPER FDOT INDEX NO. 1734656" DOUBLE SOLID YELLOW LINESHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18CONCRETECONFORMED SET40
N0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014TURN LANE DESIGN PLAN ATINTERSECTION OF E. AIRPORT BLVD.AND RED CLEVELAND BLVD.IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037Key MapLEGENDMATCH LINESAW-CUT / MATCH EXISTINGHEAVY DUTY FLEXIBLE PAVEMENTSEE DETAIL 1.11, SHEET C1.18TYPE "F" CURB WITH CURB CUTNOTE:SEE SIGNAL PLAN FOR TRAFFIC SIGNAL DETAILCONFORMED SET41
RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREA
KEEP OUT
GENE
R
AT
O
R
DT(ST)(NLT)TRUCKTURN-AROUNDLOADING DOCKBUILDINGFFE =LOADINGDOCK RAMPBAGGAGE BELTCOURTYARDEXISTING PARKING GARAGE - WEST SIDECOURTYARDPROPOSED BUILDINGNEW TICKETING AREAFFE =BMA AREAEXISTING CHECK-IN AREACOURTYARDEXISTING TERMINAL(SEE ARCHITECTURAL PLAN)EXISTING TERMINAL(SEE ARCHITECTURAL PLAN)FIRE HYDRANTFIRE HYDRANTFIRE HYDRANTGATES 1-5 AND NEW GATES / BAG CLAIMS 4, 5 AND 6PHASE 3SAA OFFICES / WESTERNCBP / BAG CLAIM 3PHASE 1PARKING GARAGETICKETING / GATES 6-12 / SCREENING / BAG CLAIM 1 AND 2PHASE 2LOADING DOCK / BADGING / POLICEPHASE 1FDCFIRE HYDRANTSEE SHEET C3.04 FOR FIRE LINESEE SHEET C1.07 FOR FIRE LINESEE SHEET C1.06 FOR FIRE LINESEE SHEET C2.04 FOR FIRE LINESEE SHEET C1.06 FORF.H. CONNECTIONArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014REFERENCE ONLY FIRE LINE PLANIBDRBJDOJDO1" = 50'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037N0Graphic Scale in Feet5050100CONFORMED SET42
Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014BOLLARD LAYOUT PLANIBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037N0Graphic Scale in Feet404080CONFORMED SET43
RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUTSITSITE BENCHMARK # 1GENERATORDCOMPACTORT34203420LOADING DOCKBUILDINGLOADING DOCKRAMPTREE PROTECTIONGUTTER BUDDYSEE DETAIL 1.3, SHEET C1.17CEArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014STORMWATER POLLUTION PREVENTION PLANPHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037N0Graphic Scale in Feet202040TOTAL DISTURBED AREA 1.89 AC.203420SOILS LEGENDSOILS BOUNDARY LINEURBAN LANDMYAKKA AND EAU GALLIE FINE SANDSAREA SUMMARYLEGENDPROPOSED FLOW LINESLIMITS OF DISTURBANCESEEDING/VEGETATION STABILIZATIONPROPOSED INLET PROTECTIONFOR DETAILS, SEE SHEET C1.17SOIL TYPECETEMPORARY CONSTRUCTION EXITSEE DETAIL 1.1, SEE SHEET C1.17CONFORMED SET44
(LTO)(S)(SVO)(ST)(SVO)LIMITS OF DISTURBANCELIMITS OF DISTURBANCEGUTTERBUDDYGUTTERBUDDYGUTTER BUDDYGUTTER BUDDYGUTTER BUDDYSEE DETAIL 1.3, SHEET C1.17LIMITS OF DISTURBANCELIMITS OF DISTURBANCEN0Graphic Scale in Feet202040Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014STORMWATER POLLUTIONPREVENTION PLAN PHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037PROPOSED INLET PROTECTIONFOR DETAILS, SEE SHEET C1.17SEEDING/VEGETATION STABILIZATIONSOIL TYPE: X SANDTOTAL DISTURBED AREA 0.85 AC.TEMPORARY SILT FENCELIMITS OF DISTURBANCEPROPOSED FLOW LINESSOILS BOUNDARY LINEPOMELLO FINE SANDS2027LEGENDSOILS LEGENDAREA SUMMARYCONFORMED SET45
LIMITS OF DISTURBANCELIMITS OF DISTURBANCETEMPORARY SILT FENCESEE DETAIL 1.4, SHEET C1.17N0Graphic Scale in Feet202040PROPOSED INLET PROTECTIONFOR DETAILS, SEE SHEET C1.17SEEDING/VEGETATION STABILIZATIONSOIL TYPE: X SANDTOTAL DISTURBED AREA 0.65 AC.TEMPORARY SILT FENCESEE DETAIL 1.4, SHEET C1.17LIMITS OF DISTURBANCEPROPOSED FLOW LINESSOILS BOUNDARY LINEPOMELLO FINE SANDS2027LEGENDSOILS LEGENDAREA SUMMARYwww.sunshine811.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014STORMWATERPOLLUTION PREVENTIONPLAN PHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037CONFORMED SET46
SEQUENCE OF CONSTRUCTIONTHE CONTRACTOR SHALL FOLLOW THE SEQUENCE OFCONSTRUCTION AS DESCRIBED BELOW. IF THE CONTRACTORFINDS THAT THE SEQUENCE NEEDS TO BE MODIFIED, THECONTRACTOR SHALL CONTACT THE CEC FOR FURTHERDIRECTION. THE INSTALLATION OR REMOVAL OF BMPS, EARTHDISTURBANCE, GRADING, TEMPORARY STABILIZATION ANDPERMANENT STABILIZATION SHALL BE IMMEDIATELY NOTED IN THESWPPP IMPLEMENTATION LOG AND ON THE SITE MAP. THECONTRACTOR SHALL DISTURB ONLY THOSE AREAS NECESSARYTO INSTALL THE BMPS UNTIL DIRECTED IN THE SEQUENCE TOBEGIN CLEARING AND GRUBBING OPERATIONS. ALL TEMPORARYBMPS SHALL BE REPAIRED AND MAINTAINED UNTIL STABILIZATIONHAS OCCURRED AND THERE IS NO RISK OF DISCHARGE, THENTHEY SHALL BE REMOVED.1. POST A COPY OF THE NOI OR LETTER FROM FDEP CONFIRMINGCOVERAGE UNDER THE GENERIC PERMIT, AND THE NAME ANDPHONE NUMBER OF THE CONTRACTOR'S REPRESENTATIVERESPONSIBLE FOR EROSION AND SEDIMENTATION CONTROLINSTALLATION AND MAINTENANCE ON A 24 HOUR BASIS.2. INSTALL PERIMETER CONTROLS IMMEDIATELY DOWNSTREAMOF THE PLANNED LOCATION OF THE CONSTRUCTION EXIT.3. INSTALL STABILIZED CONSTRUCTION EXIT.4. INSTALL REMAINING PERIMETER CONTROLS.5. INSTALL TEMPORARY PARKING AND STORAGE AREAS (TRAILER,PARKING, LAY DOWN, SANITARY FACILITIES, WHEEL WASH,CONCRETE WASHOUT, MASONS AREA, FUEL AND MATERIALSTORAGE CONTAINERS, SOLID WASTE CONTAINERS, ETC).6. CONSTRUCT AND STABILIZE THE SEDIMENT BASINS ANDSEDIMENT TRAPS WITH APPROPRIATE OUTFALL STRUCTURES7. CONSTRUCT AND STABILIZE HYDRAULIC CONTROLS (DITCHES,SWALES, DIKES, CHECK DAMS, ETC.).8. BEGIN DEMOLITION, CLEARING AND GRUBBING OPERATIONS ASAPPLICABLE.9. BEGIN CONSTRUCTION OF BUILDING PAD AND STRUCTURES.10. TEMPORARILY SEED, IMMEDIATELY AND THROUGHOUTCONSTRUCTION, DENUDED AREAS THAT WILL BE INACTIVE FOR7 DAYS OR MORE.11. INSTALL UTILITIES, UNDERDRAINS, STORM SEWERS, CURBSAND GUTTERS.12. INSTALL RIP RAP AROUND OUTLET STRUCTURES AS EACHOUTLET STRUCTURE IS INSTALLED.13. INSTALL INLET PROTECTION AROUND ALL STORM SEWERSTRUCTURES AS EACH INLET STRUCTURE IS INSTALLED.14. PERMANENTLY STABILIZE AREAS TO BE VEGETATED AS THEYARE BROUGHT TO FINAL GRADE.15. PREPARE SITE FOR PAVING.16. PAVE SITE.17. INSTALL APPROPRIATE INLET PROTECTION DEVICES FORPAVED AREAS AS WORK PROGRESSES.18. COMPLETE GRADING AND INSTALL PERMANENT STABILIZATIONOVER ALL AREAS.19. REMOVE ALL TEMPORARY EROSION AND SEDIMENT CONTROLDEVICES (ONLY IF SITE IS STABILIZED).20. SUBMIT NOTICE OF TERMINATION (NOT) ONCE ALLCONSTRUCTION IS COMPLETE AND ALL AREAS ARE STABILIZEDPER PLAN.NOTE:CONTRACTOR SHALL PAY CLOSE ATTENTION WHEN CLEARING AND/ORGRADING THE SITE TO ENSURE THAT WHEN EXISTING ROOTS AREENCOUNTERED THEY ARE CUT OFF EVENLY WITH CLEAN SHARP PRUNINGTOOLS. CONTRACTOR SHALL BE RESPONSIBLE FOR MINIMIZING THEDAMAGE OF THE EXISTING ROOT SYSTEMS.JAN* THIS IS ONLY A GUIDE, CONTRACTOR IS TO USE HIS JUDGMENT TO MODIFY AS NEEDED.PERMANENT CONTROL MEASURESFINISH GRADINGSITE CONSTRUCTIONFOUNDATION / BUILDING CONSTRUCTIONROUGH GRADE / SEDIMENT CONTROLSTORM FACILITIESTEMPORARY CONTROL MEASURESCONSTRUCTION ENTRANCEANTICIPATED CONSTRUCTION SEQUENCE*CONSTRUCTION SEQUENCING TABLEFEB MAR APR MAY JUNJUL AUG SEPTHIS PLAN HAS BEEN PREPARED TO ENSURE COMPLIANCE WITH RULES OF THE FLORIDADEPARTMENT OF ENVIRONMENTAL PROTECTION, CHAPTER 17-25-FAC AND THE ST. JOHN'SRIVER WATER MANAGEMENT DISTRICT.SITE DESCRIPTIONA. SITE LOCATION:THE SITE IS LOCATED AT THE LOADING / RECEIVING AREA OF THE ORLANDO SANFORDAIRPORT OFF HANGER ROAD.B. SITE CONDITIONS & ACTIVITIES NARRATIVE: THE EXISTING CONDITION OF THE SITE IS DEVELOPED WITH THE MAJORITY OF THISAREA BEING IMPERVIOUS. THIS AREA WILL REMAIN APPROXIMATELY THE SAMEGRADE WITH THE EXCEPTION BEING THE PROPOSED LOADING DOCK AREA.WETLANDS/BUFFERSTHERE ARE NO WETLANDS ON SITE.SWPPP INTENTTHE INTENT OF THIS SWPPP IS TO COMPLY WITH THE INTENT OF THE GENERIC PERMITAND TO PREVENT THE RELEASE OF SOILS, TRASH, CHEMICALS, TOXINS AND OTHERPOLLUTANTS, BY WATER , AIR, VEHICLE TRANSPORT OR OTHER MEANS THAT CANIMPACT STORM WATER QUALITY. THE CONTRACTOR SHALL OBTAIN A COPY OF THEGENERIC PERMIT AND RETAIN ON-SITE FOR FUTURE REFERENCE. THE CONTRACTORSHALL READ AND UNDERSTAND THE PERMIT, AND ENSURE THAT THE BMP'S AREINSTALLED AND THE EXECUTION OF THE WORK IS PERFORMED TO MEET THE INTENT OFTHE GENERIC PERMIT AND THE SWPPP.POTENTIAL SOURCES OF POLLUTIONTHE POTENTIAL SOURCES OF POLLUTION THAT MAY REASONABLY BE EXPECTED TOAFFECT THE QUALITY OF STORM WATER DISCHARGE ASSOCIATED WITH CONSTRUCTIONACTIVITY INCLUDE:GENERAL NOTESA.IT IS THE CONTRACTOR'S RESPONSIBILITY TO FILE "NOTICE OF INTENT TO USE GENERICPERMIT FOR STORMWATER DISCHARGE FROM CONSTRUCTION ACTIVITIES" (DEP FORM62-621.300(4)(B) OR LATEST VERSION) TO FDEP TO THE FOLLOWING ADDRESS ORTHROUGH THE FDEP ON-LINE SYSTEM AT LEAST TWO (2) DAYS BEFORE COMMENCEMENTOF CONSTRUCTION:NPDES STORMWATER NOTICES CENTER, MS #2510 FLORIDA DEPARTMENT OFENVIRONMENTAL PROTECTION, 2600 BLAIR STONE ROAD, TALLAHASSEE, FLORIDA32399-2400AN ENVIRONMENTAL RESOURCE PERMIT, PERMITTED THROUGH ST. JOHNS RIVERWATER MANAGEMENT DISTRICT, HAS BEEN OBTAINED FOR THIS PROJECT. PERMIT TO BEPROVIDED.MS4 OPERATOR NAME (IF ANY): SEMINOLE COUNTY ENVIRONMENTAL SERVICES.THE CONTRACTOR SHALL PROVIDE A COPY OF THE NOI AND SUBSEQUENT NOT TO THEMS4. THE CONTRACTOR SHALL ALSO COORDINATE WITH THE MS4 TO ENSURE THAT ALLSPECIFIC REQUIREMENTS ARE MET.B.WHERE PRACTICAL, STORMWATER SHALL BE CONVEYED BY SWALES. SWALES SHALL BECONSTRUCTED AS SHOWN ON PLANS.C. EROSION CONTROL MEASURES SHALL BE EMPLOYED TO MINIMIZE TURBIDITY OFSURFACE WATERS LOCATED DOWNSTREAM OF ANY CONSTRUCTION ACTIVITY. WHILETHE VARIOUS MEASURES REQUIRED WILL BE SITE SPECIFIC, THEY SHALL BE EMPLOYEDAS NEEDED IN ACCORDANCE WITH THE FOLLOWING:I. IN GENERAL, EROSION SHALL BE CONTROLLED AT THE FURTHEST PRACTICALUPSTREAM LOCATION.II. NEW AND EXISTING STORMWATER INLETS AND OUTFALL STRUCTURES SHALL BEPROTECTED DURING CONSTRUCTION. PROTECTION MEASURES SHALL BE EMPLOYEDIMMEDIATELY AS REQUIRED DURING THE VARIOUS STAGES OF CONSTRUCTION.III. PERIMETER EROSION CONTROL DEVICES SHALL REMAIN IN PLACE UNTIL FINAL SITESTABILIZATION HAS BEEN ESTABLISHEDD. CLEARING AND GRUBBING OPERATIONS SHALL BE CONTROLLED SO AS TO MINIMIZEUNPROTECTED ERODIBLE AREAS EXPOSED TO WEATHER. GENERAL EROSION CONTROLBMP'S SHALL BE EMPLOYED TO MINIMIZE SOIL EROSION AND OFF-SITE SEDIMENTATION.WHILE THE VARIOUS TECHNIQUES REQUIRED WILL BE SITE AND PLAN SPECIFIC, THEYSHOULD BE EMPLOYED PRIOR TO ANY CONSTRUCTION ACTIVITY.E. THE CONTRACTOR SHALL FURNISH, INSTALL PER THE SEQUENCE OF CONSTRUCTION,MAINTAIN AND SUBSEQUENTLY REMOVE, ALL NECESSARY TEMPORARY BMPS. THECONTRACTOR WILL FURNISH AND INSTALL ALL NECESSARY PERMANENT BMPS.F. THE CONTRACTOR SHALL ADJUST, ADD OR MODIFY BMPS AS NECESSARY TO COMPLYWITH THE INTENT OF THE GENERIC NPDES PERMIT AND THE SWPPP FOR NO ADDITIONALCOMPENSATION. THE CONTRACTOR SHALL CONSULT WITH THE CEC PRIOR TOADJUSTING, ADDING OR MODIFYING BMPS THAT AFFECT THE HYDRAULICS OF THE SITEOR BEFORE ADDING BMPS NOT DETAILED IN THE SWPPP.G. THE CONTRACTOR IS ADVISED THAT THE CONTRACT DRAWINGS ONLY INDICATEEROSION, SEDIMENT, AND TURBIDITY CONTROLS AT LOCATIONS DETERMINED IN THEDESIGN PROCESS. HOWEVER, THE CONTRACTOR IS REQUIRED TO PROVIDE ANYADDITIONAL CONTROLS NECESSARY TO PREVENT THE POSSIBILITY OF SILTING ANYADJACENT LOWLAND PARCEL OR RECEIVING WATER.H.EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO, OR AS THEFIRST STEP IN CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR COMPLYINGWITH ALL EROSION CONTROL MEASURES SHOWN ON THE PLANS. THE EROSIONCONTROL SYSTEM DESCRIBED WITHIN THE CONSTRUCTION DOCUMENTS SHOULD BECONSIDERED TO REPRESENT THE MINIMUM ACCEPTABLE STANDARDS FOR THISPROJECT. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DEPENDENTUPON THE STAGE OF CONSTRUCTION, THE SEVERITY OF THE RAINFALL EVENT AND/ORAS DEEMED NECESSARY AS A RESULT OF ON-SITE INSPECTIONS BY THE OWNER, THEIRREPRESENTATIVES, OR THE APPLICABLE JURISDICTIONAL AUTHORITIES. THESEADDITIONAL MEASURES (IF NEEDED) SHALL BE INSTALLED AT NO ADDITIONAL COST TOTHE OWNER. IT SHOULD BE NOTED THAT THE MEASURES IDENTIFIED ON THIS PLAN AREONLY SUGGESTED BEST MANAGEMENT PRACTICES (BMPS). THE CONTRACTOR SHALLPROVIDE POLLUTION PREVENTION AND EROSION CONTROL MEASURES AS SPECIFIED INFDOT INDEXES #100 THROUGH #102 AND AS NECESSARY FOR EACH SPECIFICAPPLICATION. IT IS THE CONTRACTOR'S ULTIMATE RESPONSIBILITY TO ASSURE THAT THESTORMWATER DISCHARGE FROM THE SITE DOES NOT EXCEED THE TOLERANCESESTABLISHED BY ANY OF THE APPLICABLE JURISDICTIONAL AUTHORITIES.I DISCHARGES RESULTING FROM GROUND WATER DEWATERING ACTIVITIES ARE NOTCOVERED BY THE NPDES GENERIC PERMIT. SEPARATE PERMIT COVERAGE MUST BEOBTAINED BY THE CONTRACTOR UNDER THE DEPARTMENT'S GENERIC PERMIT FORDISCHARGE OF PRODUCED GROUND WATER FROM ANY NON-CONTAMINATED SITEACTIVITY PURSUANT TO SUBSECTION 62-621.300(2), F.A.C.J. THE CONTRACTOR SHALL ENSURE THAT THE CONTRACTOR AND ALL SUBCONTRACTORSRESPONSIBLE FOR IMPLEMENTING SWPPP CONTROL MEASURES FILL OUT THECONTRACTOR / SUBCONTRACTOR CERTIFICATION TABLE INCLUDED IN THIS SWPPP.K. THE CONTRACTOR SHALL COMPLETE THE CONSTRUCTION SEQUENCE TABLE INCLUDINGIN THIS SWPPP PRIOR TO PROCEEDING WITH THE INSTALLATION OF BMPS AND PRIOR TOGROUND DISTURBING ACTIVITIES. THE CONTRACTOR SHALL COMPLETE THE TABLE WITHANTICIPATED DATES IN WHICH THE BMP WILL BE UTILIZED OR THE ACTIVITY WILL OCCUR.STABILIZATIONA. STABILIZATION MEASURES SHALL BE INITIATED IMMEDIATELY IN PORTIONS OF THE SITEWHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED ANDWILL REMAIN UNDISTURBED FOR 7 DAYS OR MORE. STABILIZE BY COVERING WITHADEQUATE AMOUNTS OF MULCH OVER SEED AND PERIODICALLY WATER TO PROMOTEAND MAINTAIN GROWTH OF THE TEMPORARY GROUNDCOVER, OR BY THE USE OF ANAPPROPRIATE ALTERNATIVE BMP.B. PERMANENT SOIL EROSION CONTROL MEASURES FOR ALL SLOPES, CHANNELS, DITCHESOR ANY DISTURBED LAND AREAS SHALL BE COMPLETED IMMEDIATELY AFTER FINALGRADING. WHEN IT IS NOT POSSIBLE TO PERMANENTLY PROTECT A DISTURBED AREAIMMEDIATELY AFTER GRADING OPERATIONS, TEMPORARY EROSION CONTROLMEASURES SHALL BE INSTALLED. ALL TEMPORARY PROTECTION SHALL BE MAINTAINEDUNTIL PERMANENT MEASURES ARE IN PLACE AND ESTABLISHED.C. ALL GRASS SLOPES CONSTRUCTED STEEPER THAN 4H:1V SHALL BE SODDEDIMMEDIATELY AFTER FINAL GRADE IS ESTABLISHED.DUST CONTROLA. BARE EARTH AREAS SHALL BE WATERED DURING CONSTRUCTION AS NECESSARY TOMINIMIZE THE TRANSPORT OF FUGITIVE DUST. IN NO CASE SHALL FUGITIVE DUST BEALLOWED TO LEAVE THE SITE UNDER CONSTRUCTION.B. AS REQUIRED AFTER COMPLETION OF CONSTRUCTION, BARE EARTH AREAS SHALL BEVEGETATED.C. AT ANY TIME BOTH DURING AND AFTER SITE CONSTRUCTION THAT WATERING AND/ORVEGETATION ARE NOT EFFECTIVE IN CONTROLLING WIND EROSION AND/OR TRANSPORTOF FUGITIVE DUST, OTHER METHODS AS ARE NECESSARY FOR SUCH CONTROL SHALL BEEMPLOYED. THESE METHODS MAY INCLUDE ERECTION OF DUST CONTROL FENCES. IFREQUIRED, DUST CONTROL FENCES SHALL BE CONSTRUCTED IN ACCORDANCE WITHTHE DETAIL FOR A SILT FENCE EXCEPT THE MINIMUM HEIGHT SHALL BE 4 FEET.WASTE MANAGEMENTA. THE CONTRACTOR SHALL ENSURE THAT ALL WASTE AND DEBRIS ARE MANAGED DAILYSUCH THAT THEY WILL NOT IMPACT STORMWATER OR LEAVE THE PERMITTED AREA, ANDDISPOSED OF PROPERLY IN ACCORDANCE WITH APPLICABLE STATE, LOCAL ANDFEDERAL REGULATIONS.B. THE CONTRACTOR SHALL ENSURE THAT ALL CHEMICALS, OILS, FUELS, HAZARDOUSWASTE, UNIVERSAL WASTE AND TOXIC SUBSTANCES ARE PROPERLY MANAGED ANDDISPOSED OF IN ACCORDANCE WITH APPLICABLE STATE, LOCAL AND FEDERALREGULATIONS. THE CONTRACTOR SHALL ENSURE THAT WASTE IS NOT DISCHARGEDFROM THE SITE, AND DOES NOT IMPACT STORMWATER OR GROUNDWATER.C. THE CONTRACTOR SHALL PROVIDE APPROPRIATE AND ADEQUATE WASHOUT FACILITIESTO ENSURE THAT CHEMICALS AND WASTE IS NOT DISCHARGED FROM THE SITE, AND DONOT IMPACT STORMWATER OR GROUNDWATER. (E.G. CONCRETE/MASONRY WASHOUT,PAINT WASHOUT, EIFS, ETC.) THE CONTRACTOR SHALL CLEAN UP SPILLS PROMPTLYAND ENSURE THAT WASHOUT AREAS ARE PROPERLY MAINTAINED TO PROVIDEADEQUATE VOLUME TO PREVENT OVERFLOW.D. THE CONTRACTOR SHALL PROVIDE ADEQUATE SANITARY FACILITIES FOR SITEPERSONNEL, MAINTAIN THROUGHOUT CONSTRUCTION, AND PROVIDE FOR PROPERDISPOSAL IN ACCORDANCE WITH APPLICABLE STATE, LOCAL AND FEDERALREGULATIONS. SANITARY FACILITIES SHALL BE PROPERLY SECURED TO PREVENTTIPPING.E. WHEN A SPILL OF REPORTABLE QUANTITIES IS DISCOVERED ON THE SITE, THECONTRACTOR SHALL CLEAN UP ALL SPILLED MATERIALS AND DISPOSE OF INACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS. THE CONTRACTOR SHALLNOTIFY THE APPROPRIATE AUTHORITIES IN ACCORDANCE WITH APPLICABLE LAWS ANDREGULATIONS, THE OWNER AND PROJECT ENGINEER. THE CONTRACTOR SHALL RETAINCLEANUP INFORMATION AS WELL AS DISPOSAL MANIFESTS WITH THEIR SWPPP.MATERIALS MANAGEMENT, AND EQUIPMENT STAGING AND MAINTENANCEA. EXCAVATED MATERIAL SHALL NOT BE DEPOSITED IN LOCATIONS WHERE IT COULD BEWASHED AWAY BY HIGH WATER OR STORM WATER RUNOFF. STOCKPILED MATERIALSHALL BE COVERED OR ENCIRCLED WITH SEDIMENT CONTAINMENT DEVICES.B. HEAVY CONSTRUCTION EQUIPMENT PARKING AND MAINTENANCE AREAS SHALL BEDESIGNED TO PREVENT OIL, GREASE, AND LUBRICANTS FROM ENTERING SITE DRAINAGEFEATURES INCLUDING STORMWATER COLLECTION AND TREATMENT SYSTEMS.CONTRACTORS SHALL PROVIDE BROAD DIKES OR SILT SCREENS AROUND, ANDSEDIMENT SUMPS WITHIN, SUCH AREAS AS REQUIRED TO CONTAIN SPILLS OR OIL,GREASE, LUBRICANTS, OR OTHER CONTAMINANTS. CONTRACTOR SHALL HAVEAVAILABLE, AND SHALL USE, ABSORBENT FILTER PADS TO CLEAN UP SPILLSIMMEDIATELY AFTER ANY OCCURRENCE.C. THE CONTRACTOR SHALL ENSURE THAT ALL TOXIC / HAZARDOUS SUBSTANCES ANDCHEMICALS ARE PROPERLY STORED, OUT OF THE WEATHER, AND USED IN ACCORDANCEWITH MANUFACTURER'S RECOMMENDATIONS. THE CONTRACTOR SHALL ENSURE THATTHESE PRODUCTS ARE USED IN SUCH A MANNER THAT WILL NOT NEGATIVELY IMPACTSTORMWATER, GROUNDWATER OR PROTECTED SPECIES.D. THE CONTRACTOR SHALL ENSURE THAT ALL MATERIALS, EQUIPMENT, DEBRIS, WASTE,TRAILERS, AND OTHER SUPPORT RELATED ITEMS ARE CONTAINED WITHIN THEPERMITTED LIMITS OF DISTURBANCE. THE CONTRACTOR SHALL ENSURE THAT THESTORAGE AND USE OF SUCH ITEMS DOES NOT NEGATIVELY IMPACT STORMWATER ORGROUNDWATER.OFFSITE VEHICLE TRACKINGA. THE CONTRACTOR SHALL ENSURE THAT THE CONSTRUCTION EXIT IS USED BY ALLVEHICLES AND EQUIPMENT ENTERING OR LEAVING THE JOBSITE. THE CONTRACTORSHALL MONITOR AND MAINTAIN THE CONSTRUCTION EXIT TO ENSURE THAT NO SOILSARE TRACKED OFFSITE BY TIRES OR TRACKS, AND THAT NO SOILS ARE SPILLED BYTRUCKS OR EQUIPMENT LEAVING THE SITE. ALL TRACKED OR SPILLED SOILS SHALL BESHOVELED OR SWEPT FROM THE ROADWAY AND RETURNED TO THE SITE. WATER SHALLNOT BE USED TO CLEAN THE SOILS FROM THE ROADWAY UNLESS THE WATER AND SOILSARE RECOVERED BY THE USE OF A VACUUM TRUCK OR SIMILAR DEVICE.FERTILIZERS, HERBICIDES AND PESTICIDESA. THE CONTRACTOR SHALL ENSURE THAT ALL FERTILIZERS, HERBICIDES, PESTICIDES ANDSIMILAR PRODUCTS ARE PROPERLY STORED, OUT OF THE WEATHER, AND APPLIED INACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. THE CONTRACTOR SHALLENSURE THAT THESE PRODUCTS ARE USED IN SUCH A MANNER THAT WILL NOTNEGATIVELY IMPACT STORMWATER, GROUNDWATER OR PROTECTED SPECIES.B. NUTRIENTS SHALL BE APPLIED ONLY AT RATES NECESSARY TO ESTABLISH AND MAINTAINVEGETATION.INSPECTIONS AND MAINTENANCEA. THE CONTRACTOR SHALL INSPECT BMPS (I.E. DISCHARGE LOCATIONS, CONSTRUCTIONEXIT, PERIMETER CONTROLS, INLET PROTECTION, STABILIZATION, EROSION CONTROL,DOCUMENTATION, WASTE DISPOSAL AREAS, MATERIAL STORAGE AREAS, ETC.) TODETERMINE IF CONSTRUCTION ACTIVITIES HAVE ALTERED THE EFFECTIVENESS BMPS,CONFIRM BMPS ARE ACHIEVING PERMIT COMPLIANCE, AND MAINTAIN BMPS AT LEASTONCE EVERY SEVEN (7) CALENDAR DAYS, AND WITHIN 24 HOURS AFTER A RAINSTORM INEXCESS OF 0.50 INCHES.B. THE CONTRACTOR SHALL REPORT ALL INSPECTION FINDINGS AND CORRECTIVE ACTIONSTAKEN AS A RESULT OF THE INSPECTION USING THE STORMWATER POLLUTIONPREVENTION PLAN INSPECTION REPORT FORM PROVIDED BY FDEP OR AN EQUIVALENTFORM. INSPECTION REPORTS SHALL BE SIGNED BY THE INSPECTOR AND MAINTAINEDFOR FUTURE REFERENCE AS NEEDED. THE INSPECTOR MUST BE A QUALIFIED EROSIONAND SEDIMENT CONTROL INSPECTOR AS DEFINED BY THE FLORIDA DEPARTMENT OFENVIRONMENTAL PROTECTION.C. ANY MAINTENANCE, REPAIR AND NECESSARY REVISIONS TO BMP ITEMS SHALL BEADDRESSED IN A TIMELY MANNER, BUT IN NO CASE LATER THAN 7 CALENDAR DAYSFOLLOWING THE INSPECTION. UNLESS OTHERWISE SPECIFIED, ACCUMULATEDSEDIMENTS SHOULD BE REMOVED BEFORE THEY REACH ONE-HALF OF THE CAPACITY OFTHE CONTROL DEVICE.ALLOWABLE NON-STORMWATER DISCHARGESTHE GENERIC PERMIT FOR STORMWATER DISCHARGES ASSOCIATED WITHCONSTRUCTION ACTIVITIES PROHIBIT MOST NON-STORMWATER DISCHARGES DURINGTHE CONSTRUCTION PHASE. ALLOWABLE NON-STORMWATER DISCHARGES THAT OCCURDURING CONSTRUCTION ON THIS PROJECT PER PART IV.A.3 OF THE GENERIC PERMITARE: DISCHARGES FROM FIREFIGHTING ACTIVITIES; FIRE HYDRANT FLUSHING; WATERUSED TO SPRAY OFF LOOSE SOLIDS FROM VEHICLES (WASTEWATER FROM A MORETHOROUGH CLEANING, INCLUDING THE USE OF DETERGENTS OR OTHER CLEANERS ISNOT AUTHORIZED BY THIS PART) OR CONTROL DUST IN ACCORDANCE WITH PARTV.D.2.C.(2) OF THE GENERIC PERMIT; POTABLE WATER SOURCES INCLUDING WATERLINEFLUSHINGS; IRRIGATION DRAINAGE; ROUTINE EXTERNAL BUILDING WASHDOWN WHICHDOES NOT USE DETERGENTS; PAVEMENT WASHWATERS WHERE SPILLS OR LEAKS OFTOXIC OR HAZARDOUS MATERIALS HAVE NOT OCCURRED (UNLESS ALL SPILLEDMATERIAL HAS BEEN REMOVED) AND WHERE DETERGENTS ARE NOT USED; AIRCONDITIONING CONDENSATE; SPRINGS; AND FOUNDATION OR FOOTING DRAINS WHEREFLOWS ARE NOT CONTAMINATED WITH PROCESS MATERIALS SUCH AS SOLVENTS.RETENTION OF RECORDSTHE PERMITTEE SHALL RETAIN COPIES OF STORMWATER POLLUTION PREVENTIONPLANS AND ALL REPORTS REQUIRED BY THIS PERMIT, AND RECORDS OF ALL DATA USEDTO COMPLETE THE NOTICE OF INTENT TO BE COVERED BY THIS PERMIT, FOR A PERIODOF AT LEAST THREE (3) YEARS FROM THE DATE THAT THE SITE IS FINALLY STABILIZED."I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with asystem designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of theperson or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is,to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting falseinformation, including the possibility of fine and imprisonment for knowing violations."Name (Operator and/or Responsible AuthorityDateProject Name and location information:ELEVATIONRUNOFFGROUNDUNDISTURBED3'-0"(MIN.)12"COMPACTED BACKFILL(MIN)4" X 6" TRENCH WITH PONDING HEIGHTFILTER FABRIC ATTACHSECURELY TO UPSTREAMSIDE OF POSTPONDING HEIGHTFILTER FABRIC ATTACHSECURELY TO UPSTREAMSIDE OF POST(MIN.)3'-0"RUNOFF12"(MIN.)GROUNDUNDISTURBEDSTANDARD DETAILALTERNATE DETAIL A9" MAX.(RECOMMENDED)STORAGE HT.8"TRENCH WITH GRAVELTRENCH WITH NATIVE BACKFILLGRAVELFINISH GRADEFLOWFLOWFLOW10' MAX. SPACING W/ WIRESUPPORT FENCE/6' MAX.SPACING W/OUT WIRESUPPORT FENCESTEEL OR 2" X 2"WOOD POSTNOTES:1. INSPECT AND REPAIR FENCE AFTER EACH STORM EVENT AND REMOVE SEDIMENT WHEN NECESSARY.2. REMOVED SEDIMENT SHALL BE DEPOSITED TO AN AREA THAT WILL NOT CONTRIBUTE SEDIMENTOFF-SITE AND CAN BE PERMANENTLY STABILIZED.3. SILT FENCE SHALL BE PLACED ON SLOPE CONTOURS TO MAXIMIZE PONDING EFFICIENCY.EXTRA STRENGTHFILTER FABRIC NEEDEDWITHOUT WIRE MESHSUPPORTSTEEL OR 2" X 2"WOOD POSTPONDING HEIGHTFILTER FABRIC ATTACHSECURELY TO UPSTREAMSIDE OF POST(MIN.)3'-0"RUNOFF12"(MIN.)GROUNDUNDISTURBEDALTERNATE DETAIL B9" MAX.(RECOMMENDED)STORAGE HT.FOR TREE DRIP LINE OR SIDEWALKSSAND BAGS5% SLOPEDIKE IF NEEDEDTEMPORARYLESS THANFLOWDRAIN GRATEPLAN VIEWNOTES:1. DROP INLET SEDIMENT BARRIERS ARE TO BE USED FOR SMALL, NEARLYLEVEL DRAINAGE AREAS. (LESS THAN 5%).2. THE TOP OF THE FRAME (PONDING HEIGHT) MUST BE WELL BELOW THEGROUND ELEVATION DOWNSLOPE TO PREVENT RUNOFF FROMBYPASSING THE INLET. A TEMPORARY DIKE MAY BE NECESSARY ONTHE DOWNSLOPE SIDE OF THE STRUCTURE.3. FASTEN FRAMING TO STRUCTURE TO ALLOW GRATE REMOVAL.4. LEAVE EXPOSED EDGE TO ALLOW FOR PAVING TO GRADEGRATE2" X 4" VERTICALSUPPORT EACHCORNER (INSTALL TOALLOW GRATEREMOVAL)2" X 4" BRACE @CENTER2" X 4" TAP CON, 16" O.C.,3/16" X 2-3/4" (TYPICAL ALLSIDES)2"X4" PT BOX ALLSIDESWIRE FILTER FABRIC(RUN UNDER 2" X 4"AND INSIDE FRAME ANDSTAPLE IT TO SAME)RUN FILTER FABRICUNDER GRATE &OVER STRUCTUREGEOTEXTILE BAGOVERFLOW HOLESLOOPS SIZED FOR 1" REBAR.USE REBAR FOR A HANDLE TOEMPTY FILTER SACK AT ASEDIMENT COLLECTIONLOCATION.LOOPS SIZED FOR 2"X1/4"RECTANGULAR BAR. LIFTFILTER BAG FROM INLET USINGRECTANGULAR BAR FORHANDLES.2"X2"X3/4"RUBBERBLOCK (TYP)PROFILE VIEW OFINSTALLED FILTER SACKGRAB TENSILE STRENGTHGRAB TENSILE ELONGATIONPUNCTUREMULLEN BURSTTRAPEZOID TEARUV RESISTANCEAPPARENT OPENING SIZEFLOW RATEPERMITTIVITYPROPERTIES TEST METHOD UNITSASTM D-4632ASTM D-4632ASTM D-4833ASTM D-3786ASTM D-4533ASTM D-4355ASTM D-4751ASTM D-4491ASTM D-4491300 LBS20 %120 LBS800 PSI120 LBS80 %40 US SIEVE40 GAL/MIN/SQ FT0.55 SEC -1GRAB TENSILE STRENGTHGRAB TENSILE ELONGATIONPUNCTUREMULLEN BURSTTRAPEZOID TEARUV RESISTANCEAPPARENT OPENING SIZEFLOW RATEPERMITTIVITYPROPERTIES TEST METHOD UNITSASTM D-4632ASTM D-4632ASTM D-4833ASTM D-3786ASTM D-4533ASTM D-4355ASTM D-4751ASTM D-4491ASTM D-4491LOW TO MODERATE FLOW GEOTEXTILE FABRIC SPECIFICATION TABLEMODERATE TO HIGH FLOW GEOTEXTILE FABRIC SPECIFICATION TABLE265 LBS20 %135 LBS420 PSI45 LBS90 %20 US SIEVE200 GAL/MIN/SQ FT1.5 SEC -1INLET GRATE1/4" BRIGHTLYCOLORED NYLONROPE EXPANSIONRESTRAINTISOMETRIC VIEWSECTION VIEWSECURE RECTANGULAR BAR TO ORUNDER SURROUNDING SURFACE.1/4" BRIGHTLY COLOREDNYLON ROPE EXPANSIONRESTRAINTDEPTH = DFINISHGRADE1. REMOVE TRAPPED SEDIMENT WHEN BRIGHTLYCOLORED EXPANSION RESTRAINT CAN NO LONGERBE SEEN.2. GEOTEXTILE SHALL BE A WOVEN POLYPROPYLENEFABRIC THAT MEETS OR EXCEEDS REQUIREMENTS INTHE SPECIFICATIONS TABLE.3. PLACE AN OIL ADSORBENT PAD OR PILLOW OVERINLET GRATE WHEN OIL SPILLS ARE A CONCERN.4. INSPECT PER REGULATORY EQUIREMENTS.5. THE WIDTH, "W", OF THE FILTER SACK SHALL MATCHTHE INSIDE WIDTH OF THE GRATED INLET BOX.6. THE DEPTH, "D", OF THE FILTER SACK SHALL BEBETWEEN 18 INCHES AND 36 INCHES.7. THE LENGTH, "L", OF THE FILTER SACK SHALL MATCHTHE INSIDE LENGTH OF THE GRATED INLET BOX.8. EXTRA CARE SHALL BE TAKEN TO ENSURE REGULARMAINTENANCE OF FILTER SACKS USED IN RIGHT OFWAY TO ENSURE ADEQUATE DRAINAGE CAPACITY.CAUTION: BAGGED INLET PROTECTIONREQUIRES ADDITIONAL MAINTENANCETO ENSURE THAT THE BMP FUNCTIONSPROPERLY AND DOES NOT CAUSEFLOODING.Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014STORMWATER POLLUTION PREVENTIONDETAILS PHASE 1IBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037N.T.S.TEMPORARY CONSTRUCTION EXIT DETAIL1.1N.T.S.FILTER FABRIC INLET PROTECTION DETAIL1.2N.T.S.CURB INLET PROTECTION DETAIL1.3N.T.S.SEDIMENTATION / SILT FENCE1.4N.T.S.GEOTEXTILE BAG INLET PROTECTION DETAIL1.5SECTION 1.B - 1.B1.B1.BDIVERSION RIDGE REQUIREDWHERE GRADE EXCEEDS 2%EXISTING PAVEDROADWAYFILTER FABRIC2% OR GREATERSPILLWAYSEDIMENT BARRIER(SANDBAG TYPE SHOWN)SUPPLY WATER TO WASHWHEELS IF NECESSARY25'R20' MIN.20'R MIN.DIVERSION RIDGE50' MIN.2"-3" COARSE AGGREGATE6" THICK MIN.FLOWFLOWFLOWFLO
WNOTE:USE SANDBAGS, SILT FENCE,OR OTHER APPROVED METHODSTO CHANNELIZE RUNOFF TO BASINAS REQUIREDNOTE:1. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENTTRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY. THISMAY REQUIRE TOP DRESSING REPAIR AND/OR CLEANOUT OF ANY MEASURESUSED TO TRAP SEDIMENT.2. WHEN NECESSARY, WHEELS SHALL BE CLEANED PRIOR TO ENTRANCE ONTOPUBLIC RIGHT-OF-WAY.3. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZEDWITH CRUSHED STONE THAT DRAINS INTO AN APPROVED SEDIMENT TRAP ORSEDIMENT BASIN.SECTION 1.A - 1.A1.A1.APLANCONFORMED SET47
3'SEE SITE PLAN 60" MIN. WIDTHLANDING5' MIN.4"4" THICK CONCRETESIDEWALK SECTIONRAMPPAVEMENTSIDEWALK FLUSH WITH PAVEMENTRAMP1:12 MAX.1:12 MAX.MONOLITHIC CONCRETEHANDICAP RAMP (3000 PSI)ACCESSIBLE PARKING SPACEACCESSIBLE PARKING SPACEACCESSIBLE AISLE6"8"6"*PAVEMENT18"2"RBASE3/4" RJOINTSEAL1/2" EXP JOINT AND PREFORMEDJOINT FILLER (SEE NOTE 1)Sidewalk6' Min.4' Min.Sidewalk Curb(Where Necessary)0.020.02LandingRamp0.021:12Ramp1:12Sidewalk(5" Min.)Ramp Width(4' Min.)Ramp1:12NOTE:SEE THE LATEST EDITION OF THE FDOT INDEX FORADDITIONAL INFORMATION.1. 3/4"x4" PREMOLDED EXPANSION MATERIALS AROUND P.P. OR OTHER STRUCTURES IN WALK.2. EXPANSION JOINTS MAXIMUM DISTANCE = 100', USED 3/4"x4" PREMOLDED EXPANSION MATERIAL.3. CONTRACTION JOINTS MAXIMUM DISTANCE = 21', SAW CUT 2" DEEP AND FILL WITH EPOXY.4. SAW CUT JOINTS WITHIN 24 HOURS.5. BROOM FINISH UNLESS NOTED OTHERWISE.FTP-22-0412" MIN. 18" STD.12"12" MIN. 18" STD.6"18"1"1"1"1"1"1"1"1"1"1-1/2"2" OR4"6" MIN.9" STD.FTP-20-041-1/2"84" MIN2"6"3" GALV. STL. POLE*NOTES:SIGNS FTP-20-04 & FTP-22-04 SHALL BE IN ACCORDANCE WITHF.D.O.T. INDEX NO. 17355 AND SHALL MEET THE REQUIREMENTSOF FLORIDA STATUTES 316.1955 AND 316.1956.WHEN NEEDED.SUPPLEMENTAL PANEL TO BE USED AS PER LOCAL REQUIREMENTS*4" BLUE STRIPING4" WHITE SYMBOL12'50:1HANDICAP PARKINGSIGN (SEE DETAIL)4" WHITE STRIPENOTE:PARKING STALLS SHALL BE MARKED WITH WHITE& BLUE PAINT PER FLORIDA ACCESSBILITY CODESECTION 4.6.1.PER PLAN18' (TYP.) 4" WHITE STRIPE@4' O.C.2" TYP.LC CONC. SIDEWALK5'45°CONC. WHEEL STOP4" WHITE STRIPEEDGE OF PAVEMENTNOTES:2. ACCESSIBILITY: A) IN ACCORDANCE WITH THE FLORIDA ACCESSIBILITYCODE FOR BUILDING CONSTRUCTION, CHAPTER 4, DATED 2012.AT LEAST ONE ACCESSIBLE ROUTE COMPLYING WITH CHAPTER 4 SHALL CONNECT ACCESSIBLE BUILDING OR FACILITY ENTRANCES AND WITH ALL ACCESSIBLE SPACES ABD ELEMENTS WITHIN THE BUILDING OR FACILITY. DOORS ACCESSING THE BUILDING MUST BE DEPICTED ON SITE PLAN. RAMP DETAILSWITH SLOPE INFORMATION SHALL BE DEPICTED ON SITE PLAN. B) THE LOCATION OF HANDICAPPED PARKING STALLS, LOADING ZONES, SIDEWALKS AND RAMPS ON SITE SHALL MEET CHAPTER 316.1955 OF THE FLORIDA STATUTES AND THE FLORIDA ACCESSIBILITY CODE. CURB RAMPSSHALL NOT EXCEED 12:1 SLOPES PARKING SPACE AND AISLENOTE: (HANDICAP SIGN ONLY)ALL LETTERS SHALL BE BLACK AND SHALL CONFORM TO FDOT "ROADWAYAND TRAFFIC DESIGN STANDARDS".TOP PORTION OF SIGN SHALL HAVE REFLECTORIZED (ENGINEERING GRADE)BLUE BACKGROUND WITH WHITE REFLECTORIZED LEGEND AND BORDER.BOTTOM PORTION OF SIGN SHALL HAVE A REFLECTORIZED (ENGINEERINGGRADE) WHITE BACKGROUND WITH BLACK BORDER.ONE SIGN REQUIRED FOR EACH PARKING SPACE.HEIGHT OF SIGN SHALL BE 7' ABOVE GROUND IN ACCORDANCE WITH FDOT"ROADWAY AND TRAFFIC DESIGN STANDARDS".SHALL NOT EXCEED 50:1 CROSS-SLOPE. (TLO 11-26-96) 12-11-961. NUMBERS FOR ADDRESSING SHALL BE CLEARLY VISIBLE FROM THE RIGHTOF WAY, WEATHER RESISTANT AND CONTRASTING WITH THE BACKGROUND.NUMERALS SHALL BE NO LESS THAN 6 INCHES IN HEIGHT AND 1/2" WIDE 3. A SEPARATE BUILDING PERMIT (ISSUED BY THE BUILDING DIVISION)IS REQUIRED FOR ANY SIGNAGE.FOR ALL BUILDINGS.8" LIMEROCK BASE COURSE OR RECLAIMED CONCRETEAGGREGATE BASE, HAVING A MINIMUM LBR OF 100, COMPACTEDTO A MINIMUM OF 98% OF MAXIMUM DENSITY AS DETERMINED BYTHE PROCTOR PROCEDURE AND IN ACCORDANCE WITHREQUIREMENTS OF SECTIONS 200 AND 911 OF THE FDOTSTANDARD SPECIFICATIONS FOR ROAD AND BRIDGECONSTRUCTION, LATEST EDITION.12" MINIMUM STABILIZED SUB-GRADE HAVING A MINIMUM LBR OF40, COMPACTED TO A MINIMUM OF 98% OF MAXIMUM DENSITYAS DETERMINED BY THE MODIFIED PROCTOR PROCEDURE ANDIN ACCORDANCE WITH SECTION 160 OF THE FDOT STANDARDSPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION,LATEST EDITION.BCA2" FDOT TYPE SP-9.5 ASPHALTIC CONCRETE IN ACCORDANCE WITH SECTION 334 AND COMPACTED IN COMPLIANCE WITH SECTION 330-331 OF THE FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION. BAC6" LIMEROCK BASE COURSE OR RECLAIMED CONCRETEAGGREGATE BASE, HAVING A MINIMUM LBR OF 100, COMPACTEDTO A MINIMUM OF 98% OF MAXIMUM DENSITY AS DETERMINED BYTHE PROCTOR PROCEDURE AND IN ACCORDANCE WITHREQUIREMENTS OF SECTIONS 200 AND 911 OF THE FDOTSTANDARD SPECIFICATIONS FOR ROAD AND BRIDGECONSTRUCTION, LATEST EDITION.12" MINIMUM STABILIZED SUB-GRADE HAVING A MINIMUM LBR OF40, COMPACTED TO A MINIMUM OF 98% OF MAXIMUM DENSITYAS DETERMINED BY THE MODIFIED PROCTOR PROCEDURE ANDIN ACCORDANCE WITH SECTION 160 OF THE FDOT STANDARDSPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION,LATEST EDITION.BCA1.5" FDOT TYPE SP-9.5I ASPHALTIC CONCRETE IN ACCORDANCE WITH SECTION 334 AND COMPACTED IN COMPLIANCE WITH SECTION 330-331 OF THE FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION. BACCURBING GENERAL NOTES 1. THE CONCRETE FOR CURBS SHALL BE DEPARTMENT OF TRANSPORTATION CLASS "I" CONCRETE, AND HAVE A COMPRESSIVE STRENGTH OF 3000 PSI.2. ALL CURBS SHALL HAVE CONTRACTION JOINTS AND SHALL BE CONSTRUCTED AT INTERVALS NOT TO EXCEED 10'- 0" ON CENTERS FOR ALL CURBS.6' Min.18" DIA. CONCRETEFOOTINGFINISH SURFACE3'-0"4'-0"3"6" DIA. ,CONC. FILLED#40 STEEL BOLLARD WITH1/4" YELLOW, DOMED TOPSLEEVE REQUIRED2"R3"RArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014GENERAL DETAILSIBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037PAVEMENTTOP OF CURB3'TRANS.ELEVATION VIEWN.T.S.SIDEWALK RAMP1.6N.T.S.PEDESTRIAN CROSSING SIGN1.8N.T.S.HEAVY DUTY FLEXIBLE PAVEMENTCONSTRUCTION DETAIL1.11N.T.S.LIGHT DUTY FLEXIBLE PAVEMENTCONSTRUCTION DETAIL1.12N.T.S.INTEGRAL CONCRETE SIDEWALK1.7N.T.S.TYPE D CURB DETAIL1.9N.T.S.TYPE F CURB AND GUTTER1.10N.T.S.ACCESSIBLE SIGN DETAIL1.15N.T.S.HANDICAP PARKING STALL STRIPING DETAIL1.16N.T.S.NOSE DOWN CURB DETAIL1.17N.T.S.FDOT INDEX 304 CR-C RAMP DETAIL1.18N.T.S.FDOT INDEX 304 CR-E RAMP DETAIL1.19N.T.S.BOLLARD DETAIL1.20N.T.S.CONCRETE SIDEWALK DETAIL1.14BAC4" LIMEROCK BASE COURSE OR RECLAIMED CONCRETEAGGREGATE BASE, HAVING A MINIMUM LBR OF 100, COMPACTEDTO A MINIMUM OF 98% OF MAXIMUM DENSITY AS DETERMINED BYTHE PROCTOR PROCEDURE AND IN ACCORDANCE WITHREQUIREMENTS OF SECTIONS 200 AND 911 OF THE FDOTSTANDARD SPECIFICATIONS FOR ROAD AND BRIDGECONSTRUCTION, LATEST EDITION.4" MINIMUM STABILIZED SUB-GRADE HAVING A MINIMUM LBR OF40, COMPACTED TO A MINIMUM OF 98% OF MAXIMUM DENSITYAS DETERMINED BY THE MODIFIED PROCTOR PROCEDURE ANDIN ACCORDANCE WITH SECTION 160 OF THE FDOT STANDARDSPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION,LATEST EDITION.BCACOMPACTED SUBGRADE6" P.C. NON-REINFORCED CONCRETE PAVEMENTN.T.S.6" CONCRETE PAVEMENT1.13SECTION 1.C - 1.C1.C1.C3'- 0"7 1/2"7 1/2"1'-2"1'-10"N.T.S.CONCRETE VALLEY GUTTER DETAIL1.29SECTION 1.K - 1.K1.K1.K6 1/4"2'7 1/2"1' - 2"10"3/4" R.SLOPE TO FITDRIVEWAYNOTES:1. THE CONCRETE FOR CURBS SHALL BE DEPARTMENT OF TRANSPORTATIONCLASS "I" CONCRETE, AND HAVE A COMPRESSIVE STRENGTH OF 3000 PSI.2. ALL CURBS SHALL HAVE CONTRACTION JOINTS AND SHALL BE CONSTRUCTEDAT INTERVALS NOT TO EXCEED 10' - 0" ON CENTERS FOR ALL CURBS.N.T.S.CONCRETE MIAMI CURB1.28CONFORMED SET48
NOTE: ALL TRAFFIC FLOW ARROWS TO BE REFLECTIVE YELLOW PAINT PER SPECS.Typ.1'-9"1'-0"3'-9"Typ.Typ.2'-0"RIGHT TURNTyp.1'-0"4'-9"2'-0"RTyp.LEFT TURN4'-9"2'-0"R1'-0"4"Typ.3' MIN FROMFACE OF CURBSIGNAGEEDGE OF THE CROSSWALKSTOP BAR TO BE PLACED 4' MIN. FROM EDGEOF CROSS WALK (PER FDOT MUTCD 2000),UNLESS OTHERWISE SHOWN ON THE SITEPLAN."STOP" BAR SHALL BE 24" WIDE AND 12' FOOT LONG,OR AS SHOWN ON SITE PLAN, WHITE REFLECTIVEPAINT. (SEE SITE PLAN FOR LOCATIONS)4' MIN.2' MIN.R1-1R5-1Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014GENERAL DETAILSIBDRBJDOJDO1" = 20'10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 650376" CURB2'REOP3'6"SEE PLAN18"CONC. 3,000 PSI4"6"C & GSEE GRADING PLANFOR SLOPE4"10"CONCRETE: 28 DAY COMPRESSION STRENGTH, 3,000P.S.I., 4"THICK MINIMUM W/ 6X6-W1.4XW1.4 WWF.PLAN VIEW10'10'20'6"2500 P.S.I.CLASS D CONCRETE8" DIA. PVC SANITATION PIPEFINISHED GRADEN.T.S.DO NOT ENTER SIGN1.21N.T.S.FLUME DETAIL1.26N.T.S.CONCRETE ENCASEMENT DETAIL1.27N.T.S.TRAFFIC FLOW ARROWS1.25N.T.S.STOP BAR DETAIL WITH SIGNAGE1.24N.T.S.STOP SIGN1.23N.T.S.NO LEFT / NO RIGHT TURN SIGNS1.22SECTION 1.D - 1.DSECTION 1.E - 1.E1.D1.D1.E1.E5'4"4.53 s.f.USE OF PAVEMENT SYMBOL IN ACCESSIBLEPARKING SPACES IS OPTIONAL, WHEN USED THESYMBOL SHALL BE 3' OR 5' HIGH AND WHITE IN COLORN.T.S.UNIVERSAL SYMBOL OF ACCESSIBILITY1.32DOUBLE CHECK OR REDUCEDPRESSURE ZONE DETECTORASSEMBLY AS APPROVED BY THE CITYTEST COCK (TYP.)FLANGED 90°BEND (2 REQ.)O.S. & Y. RESILIENTSEAT GATE VALVE.(2 REQUIRED)RODS ON D.I.P. RISER (TYP.)4" CONCRETE SLABWITH NO. 6 X 6W10 X W10WIRE MESH1/2" PREFORMED JOINTMATERIAL BETWEENPIPE AND CONCRETESLAB (TYP.)THRUST COLLAR RODDED TO90° BEND OR AS REQUIREDBY THE CITYADJUSTABLE PIPESUPPORT STANDSTHRUST COLLAR RODDED TO 90° BENDOR RESTRAINED BACK TO VALVEAS REQUIRED BY THE CITY90° BEND (2 REQUIRED)36" MIN.COVER24"12" MIN.36" MAX.SLOPESLOPETOSERVICEFROMMAIN3 INCH AND ABOVE ASSEMBLYDETECTOR METERBALL VALVE(2 REQUIRED)DOUBLE CHECK VALVEASSEMBLY (MIN.)CONCRETE SLAB5'0" MIN.1'0" MIN.2'-0"MIN.ABOVE GROUND DEVICE WITHDETECTOR BYPASSN.T.S.DOUBLE CHECK OR REDUCED PRESSUREZONE DETECTOR ASSEMBLY1.30DOUBLE CHECK ORREDUCED PRESSURE DEVICEUNIONFINISHEDGRADEUNIONSCHEDULE 40 GALVANIZEDPIPE AND FITTINGS ORSCHEDULE 80 PVC PIPEAND FITTINGSMETER BOX AND LIDTO BE FLUSH WITHFINISHED GRADECURBSHUT OFF VALVE4" TO 6"METERCURB STOPSERVICE LINECORP. STOPDOUBLE STRAP SADDLEWATER MAIN12" TO 30"ABOVE GRADE⅊NOTES:1. A POSITIVE DIELECTRIC CONNECTION SHALL BE MADEBETWEEN ALL GALVANIZED AND BRASS COMPONENTS.2. METER SHALL BE INSTALLED BETWEEN SIDEWALK AND CURBWHERE APPLICABLE, OR AT PROPERTY LINE AND IN NO CASESHALL IT BE INSTALLED IN SIDEWALK OR OTHER PAVED AREAS.3. USE PRIMER SUITED TO BASE MATERIALS. FINISH WITH TWOCOATS OF BLACK EXTERIOR ENAMEL.N.T.S.DOMESTIC METER AND DOUBLE CHECK VALVEOR REDUCED PRESSURE ZONE ASSEMBLY1.31HYDRANTOPERATING NUT24" SQUARE AND6" THICK REINFORCEDCONCRETE SHEAR PAD(SEE NOTE 2, THIS SHEET)2 - #4 AT 9"O.C. ALL AROUNDCOMPACTEDBACKFILLSEE NOTE 3,THIS SHEET6" BEDDING ROCK6" PIPEMECHANICAL JOINT WITHRESTRAINERS (TYP.)RESILIENT SEAT GATEVALVE AND BOX(SEE FIGURE 400)M J HYDRANTANCHORING TEEVALVE PAD(SEE FIGURE 107)AS REQUIREDPUMPER NOZZLEFACING STREET18" MIN.24" MAX.VARIES12" MIN.6"NOTES:1. FIRE HYDRANT SHALL BE SUPPLIED WITHOUT A WEEP HOLE, OR WITH APERMANENTLY PLUGGED WEEP HOLE.2. THE DEVELOPER SHALL INSTALL THE SHEAR PAD RECESSED 6 INCHES BELOW THEFINISHED GRADE AND SOD THE RECESSED SECTION.3. CLEARANCE BETWEEN BOTTOM OF BOLTS AND TOP OF SHEAR PAD SHALL BE A 12INCH MINIMUM.4. FIRE HYDRANTS SHALL BE MUELLER A-423, AMERICAN DARLING B-84, KENNEDY K81AOR CLOW MEDALLION F-2545.5. FIRE HYDRANTS SHALL BE IDENTIFIED IN ACCORDANCE WITH SECTION 52.7.5 OF THEUTILITIES MANUAL.6. CONTRACTOR SHALL PROVIDE THE CITY WITH HYDRANT WRENCHES AND VALVEKEYS IN ACCORDANCE WITH SECTIONS 52.4 AND 52.7.3 OF THE UTILITIES MANUAL.OPENCAST 2 PLACES180° APART5"12" DIA.6-1/4" DIA.6.84"30"DEPTH OF TRENCH AS SPECIFIED BY CUSTOMERGROUND LINE3.38"1/2" NPT TAPFOR TAMPERSWITCH(4) 3/4 DIA. BCON 10-1/2" DIA. BCNOTES:1. UL LISTED AND FM APPROVED2. POST MAY BE ORDERED IN THE FOLLOWING WAYS:ORDER PER A SPECIFIC APPLICATION. SPECIFY VALVE SIZE, DEPTH OF TRENCHAND OPEN DIRECTION POST IS TO BE USED WITH. THE POST IS INSTALLED AS ISWITH NO MODIFICATIONSIF POSTS ARE STOCKED: SPECIFY MOST COMMON VALVE SIZE ANTICIPATED,LONGEST DEPTH OF TRENCH ANTICIPATED, OPEN DIRECTION (IF KNOWN) OR A"DUAL ARROW" POST MAY BE ORDERED AND MODIFIED TO OPEN LEFT OR RIGHT.STOCKED POSTS WILL REQUIRE MODIFICATIONS AT THE TIME OF INSTALLATION.N.T.S.FIRE HYDRANT ASSEMBLY DETAIL1.34N.T.S.IP-71 INDICATOR POST1.33CONFORMED SET49
Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No.C 2017RevisionBy7500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.PROJECT ALPHA ONE (TERMINAL EXPANSION)S12014ROADWAY SIGNAGE PLANIBDRBJDOJDON.T.S.10/07/15 1200 RED CLEVELAND BLVD. SANFORD, FL 32773Jeremiah D. Owens, P.E.FL. P.E. 65037NAirport SignDesignatorProposed ChangesDimensionsAReplace left panel with updated language.24' x 12'BNo change.11' x 6'CReplace left panel with updated language.26' x 8'DReplace both panels with updated langauge.26' x 16'ENo change.6' x 6'FRemove Sign and Base.10' x 11'GReplace panels with updated language.12' x 10'HRemove sign and Base10' x 11'IReplace panel with updated language.26' x 18'JNo change.8' x 6'KNo change.8' x 6'LReplace panel with updated language.8' x 6'MNo change.8' x 7'NNo change.12' x 17'OReplace both panels with updated langauge.(2) 14' x 17'PRemove sign and base.10' x 8'QRemove sign and base.10' x 8'RRemove sign and base.10' x 6'SNo change.16' x 8'TReplace all panels with updated language.(3) 12' x 17'UNo change.8' x 8'VNo change.8' x 8'WReplace both panels with updated langauge.(2) 19' x 17'XNo change.10' x 8'YRelocate.10' x 8'ZReplace panel with updated language.10' x 10'AAReplace panel with updated language.10' x 11'BBNo change.19' x 17'CCNo change.11' x 6'DDNo change.19' x 17'EENew sign and foundation.10' x 11'FFReplace panel with updated language.10' X 8'CONFORMED SET50
NO PAR
K
I
N
G
FIR
E
LANENDING
ORSTARESTRICTED AREA
RESTR
I
CT
ED
AR
EA
KEEP
OU
T
RESTR
I
CTED
AREA
KEEP
OUT
RESTRICTED AREAKEEP OUT RESTRICTED AREAKEEP OUT RESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUT RESTRICTED AREAKEEP OUT RESTRICTED AREA KEEP OUTRESTRICTED AREAKEEP OUTRESTRICTED AREAKEEP OUT RESTRICTED AREAKEEP OUT RESTRICTED AREAKEEP OUT RESTRICTED AREA KEEP OUT RESTRICTED AREA KEEP OUTRESTRICTED AREA KEEP OUT
RESTRICTED AREAKEEP O
U
TRESTRICTED AREA
KEEP OUT
RESTRICTED A
REA
KEEP OUTRESTRICTED AREA
KEEP OUT
GENE
R
A
T
O
R
(LTO)(S)(SVO)(ST)(SVO)(ST)(NLT)GENERATORSG2SG2SG2
SG2SG2SG2SG2SG2
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:03am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014SHEET LAYOUTPHASE 11"=100'SCALE: 1"= 100'50 1002000Know what'sRL1.00L1.01L1.02L1.03L1.04L1.05L1.06L1.07L1.08RED CLEVELAND BLVD.HANGAR RD.AIRLINE AVE.AIRPORT RD.1CONFORMED SET51
GENER
A
T
O
R
COMPACTORAIRLINE AVE.PROPO
S
E
D
B
U
I
L
D
I
N
G
A
N
D
L
O
A
D
I
N
G
D
O
C
K
SP4SP2SR3LI12CV33MC46MC50AZ22MATCH
L
I
N
E
L
1
.
0
6 SESESESESESESESESE666PROPOSED SEMINOLE CHIPSAPPLIED AT A 3" DEPTHPROPOSED SITE LIGHT TYP.PROPOSED SEMINOLE CHIPSAPPLIED AT A 3" DEPTHRE-SOD AREAS DISTURBEDDURING CONSTRUCTIONPROPOSED SEMINOLE CHIPSAPPLIED AT A 3" DEPTHPROP. EXPANSIONJOINT TYP.PROP. SCORE JOINTTYP.PROP. EXPANSIONJOINT TYP.PROP. SCORE JOINTTYP.1N. 1614615.60E. 577397.35N. 1614598.78E. 577380.10N. 1614599.08E. 577365.11N. 1614557.17E. 577322.16N. 1614557.54E. 577292.09N. 1614553.83E. 577282.81N. 1614539.86E. 577268.49521.4760.63PROPOSED PRECASETCONCRETE WALL PER FDOTINDEX 5200, TOP OF POSTCOLLARS ARE TO BE A MINIMUM1.0' BELOW FINISHED GRADE TOALLOW FOR SIDEWALK CROSSINGAND PLANT MEDIUM. PANELLENGTHS ARE AS SHOWN ANDHEIGHTS 8'.REFER TO CIVIL PLANS FORDETAIL AND SPECIFICATIONSL1 RK1 RED KNOCKOUT ROSELI CRAPE MYRTLECH EUROPEAN FAN PALMLC DWARF RUBY LOROPETALUM LJ1JAPANESE LIGUSTRUMTREESPLANT LIST - PHASE 1SYM. COMMON NAMESP SABAL PALMIV DWARD YAUPON HOLLYVOSWEET VIBURNUMSOD ST. AUGUSTINE GRASSSM DWARF SABAL PALMETTO PX XANADUE PHILODENDRONTA TRICOLOR JASMINEAA LILY OF THE NILELCDWARF RUBY LOROPETALUM GROUNDCOVERCV LIL JOHN BOTTLE BRUSHSR ORANGE BIRD OF PARADISESHRUBS LI1 CRAPE MYRTLESNWHITE BIRD OF PARADISETS DWARF OYSTER PLANTDT VARIEGATED BLUEBERRY FLAX LILY PSA WHITE FOUNTAIN GRASSAZ VARIEGATED SHELL GINGERMC MUHLY GRASSMC1 MUHLY GRASSZP COONTIETD DWARF FAKAHATCHEE GRASS TPC CANARY ISLAND DATE PALMLN NATCHEZ CRAPE MYRTLEJ:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Sep 18, 2017 - 1:00pm dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510200LANDSCAPE AREA 1SCALE: 1" = 10'PHASE 1LANDSCAPE AREA 1Know what'sR108/11/17DRB09-18-17 ADDENDUM #4 FDOT INDEX 5200 WALL DRB3CONFORMED SET52
SITE BENCHMARK # 2L1MATCHLINE L1.02TA961SR3CV56AA114PX37PX72CV70MC191LC40RED CLEVELAND BLVD.RENTAL CAR RETURNMATCHLINE L1.01NOTE:EXISTING TREES,PALMS, SHRUBS AND GROUND COVERSARE TO BE REMOVED.EXISTING WATER LINEEXISTING ELECTRICAL LINEEXISTING CURBEXISTING PAVEMENTAPPROX. LOC.EXISTING POLE W/ LIGHTEXISTING FENCE APPROX. LOC.RK1 RED KNOCKOUT ROSELI CRAPE MYRTLECH EUROPEAN FAN PALMLC DWARF RUBY LOROPETALUM LJ1JAPANESE LIGUSTRUMTREESPLANT LIST - PHASE 1SYM. COMMON NAMESP SABAL PALMIV DWARD YAUPON HOLLYVOSWEET VIBURNUMSOD ST. AUGUSTINE GRASSSM DWARF SABAL PALMETTO PX XANADUE PHILODENDRONTA TRICOLOR JASMINEAA LILY OF THE NILELCDWARF RUBY LOROPETALUM GROUNDCOVERCV LIL JOHN BOTTLE BRUSHSR ORANGE BIRD OF PARADISESHRUBS LI1 CRAPE MYRTLESNWHITE BIRD OF PARADISETS DWARF OYSTER PLANTDT VARIEGATED BLUEBERRY FLAX LILY PSA WHITE FOUNTAIN GRASSAZ VARIEGATED SHELL GINGERMC MUHLY GRASSMC1 MUHLY GRASSZP COONTIETD DWARF FAKAHATCHEE GRASSPC CANARY ISLAND DATE PALMLN NATCHEZ CRAPE MYRTLEJ:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:03am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1LANDSCAPE AREA 2LANDSCAPE AREA 2SCALE: 1" = 10'1CONFORMED SET53
SITE BENCHMARK # 2 L1
MATCHLINE L1.03MATCHLINE L1.02MATCHLINE L1 02TA1309SR3SR3SR3SR3SR3SR3MC12CV29LC103AA54AA54MC74PX257AA54CV10RED CLEVELAND BLVD.MATCHLINE L1.01NOTE:EXISTING TREES, SHRUBS AND GROUNDCOVERS ARE TO BEREMOVED.H RECEPTACLEEXISTING ELECTRICAL LINESEXISTING WATER LINEEXISTING FENCETRK1 RED KNOCKOUT ROSERLI CRAPE MYRTLECH EUROPEAN FAN PALMLC DWARF RUBY LOROPETALUM LLJ1JAPANESE LIGUSTRUMTREESPLANT LIST - PHASE 1SYM. COMMON NAMESP SABAL PALMSIV DWARD YAUPON HOLLYIVOSWEET VIBURNUMVSOD ST. AUGUSTINE GRASSSSM DWARF SABAL PALMETTO SPX XANADUE PHILODENDRONPTA TRICOLOR JASMINETAA LILY OF THE NILEALCDWARF RUBY LOROPETALUM LGROUNDCOVERCV LIL JOHN BOTTLE BRUSHCSR ORANGE BIRD OF PARADISE SSHRUBS LI1 CRAPE MYRTLELSNWHITE BIRD OF PARADISESTS DWARF OYSTER PLANTTDT VARIEGATED BLUEBERRY FLAX LILY DPSA WHITE FOUNTAIN GRASSPAZ VARIEGATED SHELL GINGER AMC MUHLY GRASSMMC1 MUHLY GRASSMZP COONTIEZTD DWARF FAKAHATCHEE GRASS TPC CANARY ISLAND DATE PALM PLN NATCHEZ CRAPE MYRTLELJ:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:03am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1LANDSCAPE AREA 3LANDSCAPE AREA 3SCALE: 1" = 10'1CONFORMED SET54
SITE BENCHMARK # 2 L1
MATCHLINE L1.04MATCHLINE L1.02MATCHLINE L1.03TA1316MC46SR3SR3SR3SR3AA54PX149LC85CV24AA44MC52RED CLEVELAND BLVD.NOTE:EXISTING TREES, SHRUBS AND GROUNDCOVERS ARE TO BEREMOVED.EXISTING WATER LINEEXISTING FIRE HYDRANTEXISTING ELECTRIC(2) EXISTING PALMS ARE TO REMAINEXISTING FENCEEXISTING POLE W/ LIGHT10' x 10' SIGHT TRIANGLEPROP. FDCRK1 RED KNOCKOUT ROSELI CRAPE MYRTLECH EUROPEAN FAN PALMLC DWARF RUBY LOROPETALUM LJ1JAPANESE LIGUSTRUMTREESPLANT LIST - PHASE 1SYM. COMMON NAMESP SABAL PALMIV DWARD YAUPON HOLLYVOSWEET VIBURNUMVSOD ST. AUGUSTINE GRASSSM DWARF SABAL PALMETTO PX XANADUE PHILODENDRONTA TRICOLOR JASMINEAA LILY OF THE NILELCDWARF RUBY LOROPETALUM GROUNDCOVERCV LIL JOHN BOTTLE BRUSHSR ORANGE BIRD OF PARADISESHRUBS LI1 CRAPE MYRTLESNWHITE BIRD OF PARADISETS DWARF OYSTER PLANTTDT VARIEGATED BLUEBERRY FLAX LILY PSA WHITE FOUNTAIN GRASSAZ VARIEGATED SHELL GINGER AMC MUHLY GRASSMC1 MUHLY GRASSZP COONTIEZTD DWARF FAKAHATCHEE GRASS TPC CANARY ISLAND DATE PALMLN NATCHEZ CRAPE MYRTLEJ:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:04am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1LANDSCAPE AREA 4LANDSCAPE AREA 4SCALE: 1" = 10'1CONFORMED SET55
SITE BENCHMARK # 2 L1
RENTAL CAR COUNTEREXISTING TERMINALMATCHLINE L1.04MATCHLINE L2.00MATCHLINE L1.03TA692TA140TA453NOTES 1. THE LOCATION OF THE EXISTING SHRUBS, HEDGE, AND PALMS ARE APPROXIMATE.RED CLEVELAND BLVD.3.0'PSA42TS93DT72PSA63TS80TS88PSA21DT106PSA34TS86EXISTING BACK FLOW PREVENTERSEXISTING WATER VALVESEXISTING FIRE HYDRANTEXISTING COVERED CROSSWALKREMOVE EXISTING CRINUM LILYEXISTING QUEEN PALM TO BE REMOVEDEXISTING PALMS TO REMAINEXISTING PALMS TO REMAINEXISTING SHRUB TO REMAINEXISTING HEDGEAPPROX. LOCATIONTO REMAINEXISTING WATER LINE10' X 10' SIGHT TRIANGLE10' X 10' SIGHT TRIANGLETYP.RK1 RED KNOCKOUT ROSERLI CRAPE MYRTLECH EUROPEAN FAN PALMLC DWARF RUBY LOROPETALUM LLJ1JAPANESE LIGUSTRUMTREESPLANT LIST - PHASE 1SYM. COMMON NAMESP SABAL PALM SIV DWARD YAUPON HOLLYVOSWEET VIBURNUMVSOD ST. AUGUSTINE GRASSSSM DWARF SABAL PALMETTO SPX XANADUE PHILODENDRONTA TRICOLOR JASMINEAA LILY OF THE NILELCDWARF RUBY LOROPETALUM LGROUNDCOVERCV LIL JOHN BOTTLE BRUSHCSR ORANGE BIRD OF PARADISE SSHRUBS LI1 CRAPE MYRTLELSNWHITE BIRD OF PARADISESTS DWARF OYSTER PLANTTDT VARIEGATED BLUEBERRY FLAX LILY DPSA WHITE FOUNTAIN GRASSPAZ VARIEGATED SHELL GINGER AMC MUHLY GRASSMMC1 MUHLY GRASSMZP COONTIEZTD DWARF FAKAHATCHEE GRASS TPC CANARY ISLAND DATE PALM PLN NATCHEZ CRAPE MYRTLELJ:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:04am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1LANDSCAPE AREA 5LANDSCAPE AREA 5SCALE: 1" = 10'1CONFORMED SET56
SITE BENCHMARK # 2 L1
RK140SODSODT2T3IV30RED CLEVELAND BLVD.EXISTINGPARKINGGARAGEAIRLINE AVE.RED CLEVELAND BLVD.RED CLEVELAND BLVD.SR3SR3VO36PC8MATCHLINE L2.00SN2LN4IV23IV45SR3SFSESESESESESESESESG1SG1SG1SG1SFSFSESESESEREFER TO ELECTRICALSHEET 2-OB-E204REFER TO ELECTRICALSHEET 2-OB-E203FLAG POLE RELOCATEDEXISTING ALUMINUM RAIL10' X 10' SIGHT TRIANGLEPROP. UP LIGHTING TYP. REFER TO ELECTRICAL PLANSREMOVE EXISTING PALMREMOVE EXISTING PALMREMOVE EXISTING PALMEXISTING GAS LINEEXISTING WATER LINTEEXISTING ELECTRIC LINEEXISTING FDCEXISTINGWATER LINEEXISTING SIGNEXISTING FIRE HYDRANTPROVIDE 2 1/2" SLEEVE FORELECTRICAL (2) 3/4" SITELIGHTING CONDUITSEXISTING SIGN TO BE RELOCATEDSP2LI CRAPE MYRTLECH EUROPEAN FAN PALMLJ1JAPANESE LIGUSTRUMTREESPLANT LIST - PHASE 1SYM. COMMON NAMESP SABAL PALMVOSWEET VIBURNUMSM DWARF SABAL PALMETTO LCDWARF RUBY LOROPETALUM SR ORANGE BIRD OF PARADISESHRUBS LI1 CRAPE MYRTLESNWHITE BIRD OF PARADISEPC CANARY ISLAND DATE PALMLN NATCHEZ CRAPE MYRTLERK1 RED KNOCKOUT ROSELC DWARF RUBY LOROPETALUM IV DWARD YAUPON HOLLYSOD ST. AUGUSTINE GRASSPX XANADUE PHILODENDRONTA TRICOLOR JASMINEAA LILY OF THE NILEGROUNDCOVERCV LIL JOHN BOTTLE BRUSHTS DWARF OYSTER PLANTDT VARIEGATED BLUEBERRY FLAX LILY PSA WHITE FOUNTAIN GRASSAZ VARIEGATED SHELL GINGER AMC MUHLY GRASSMC1 MUHLY GRASSZP COONTIETD DWARF FAKAHATCHEE GRASS TJ:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:04am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1 LANDSCAPE AREA 6LANDSCAPE AREA 6SCALE: 1" = 10'1CONFORMED SET57
SITE BENCHMARK # 2 L1
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:04am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=30'Key MapSCALE: 1"= 30'15 30600Know what'sRPHASE 1LANDSCAPE AREA 7LANDSCAPE AREA 7SCALE: 1" = 30'1CONFORMED SET58
SITE BENCHMARK # 2 L1
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:05am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=30'Key MapSCALE: 1"= 30'15 30600Know what'sRPHASE 1LANDSCAPE AREA 8LANDSCAPE AREA 8SCALE: 1" = 30'1CONFORMED SET59
SITE BENCHMARK # 2 L1
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Sep 18, 2017 - 12:57pm dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANPHASE 11"=30'Key MapSCALE: 1"= 10'510200Know what'sRPHASE 1 LANDSCAPE AREA 9SN1SR1SR1LANDSCAPE AREA 9SCALE: 1" = 10'1SN109-18-17 ADDENDUM #4 FDOT INDEX 5200 WALL DRB11CONFORMED SET60
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 9:05am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE DETAILSSHRUB/GROUNDCOVER SPACING PLANEDGE OF BEDLINENOTE: LOCATE PLANTS IN A TRIANGULAR PATTERNAS SHOWN, SPACED EQUIDISTANT FROM EACHOTHER (AT SPACING SPECIFIED IN THE PLANT LIST).EDGE OF PAVEMENT OR CURBN.T.S.GRASSDDDOVERALL HEIGHTCLEAR WOODCLEAR TRUNKMATRIX B PALMLEAFBASESSABAL PALM(NO CROWN SHAFT)1' MIN120°EDGE OF TRENCH8' LODGE POLEEDGE OF ROOTBALLCENTER OF TREEROOT BALL MIN. 3 INCHES ABOVEGRADE4 INCHES MULCH - MAINTAIN 3-4INCHES CLEAR RADIUS AROUNDTRUNKCUT CIRCULAR ROOTS8' LODGE POLEBACKFILL MIXED WITH APPROVED TOPSOILUNDISTURBED SUBSOIL4 INCH DEEP SAUCERN.T.S.1/2" NYLON STRAPPLAN12"3"NOTE: SEE LANDSCAPE NOTES FOR THE TYPE OF MULCH MATERIAL TO USE.CONTAINER TREE PLANTING DETAILSTEEL BANDTOE NAIL5-2X4X16 WOOD BATTENS5 LAYERS OF BURLAP6'-0" MIN.N.T.S.AVOID CONTACT WITH TRUNK1 1/2"-2" APPROVED MULCHREMOVED BEFORE PLANTINGMATERIALS SHALL BE COMPLETELYALL ROOT BALL COVERINGBACKFILL MIXED WITH APPROVED TOPSOILFINISHED GRADE4" OF SAND PLACED ON BACKFILLBIODEGRADABLE TWINE. HEADMINIMUM. TIE FRONDS WITH5-7 HEALTHY FRONDSGRADE.SHALL BE LOCATED IN RELATIONSTEEL BANDS TO SECURE BATTENSAFTER SETTLEMENT, APPROX. 1" ABOVEIS EVEN WITH THE FINISHED GRADEPLANT SO THAT TOP OF ROOT BALLTRUNK. HEIGHT OF BATTENSTO THE HEIGHT OF THE PALM.DO NOT NAIL BATTENS TO PALMDURING PLANTING PROCESSSECURE BATTENS WITH 2-3/4"PUSHES IT OPEN.TO REMAIN TIED UNTIL PALM3-2X4 WOOD BRACES STAKED WITH A2X4X24" STAKE PAD BURIED 3" BELOWFINISHED GRADE AT TIME OF PLANTING.PALM STAKING DETAIL& 25% ORGANIC COMPOSTSOIL BERMMINIMUM 3" MULCHIN GROUNDCOVER PLANTING BEDSUNDISTURBED SUBSOILBACKFILL MIXED WITH 75% APPROVED TOPSOIL -PROVIDE MINIMUM PIT CLEARANCE AROUND ROOT BALL OF 6" SIDES AND BOTTOM.-MAINTAIN 3"-4" MULCH FREE ZONE AROUND BASE OF PLANT.IF SHRUB IS B & B, THEN REMOVE BURLAP &ROPE FROM TOP 1/3 OF BALL4 INCHES MULCH ( SEE LANDSCAPENOTES FOR TYPE OF MULCH )MINIMUM 12" DEPTH OF PLANTING SOILNTSSHRUB AND GROUNDCOVER PLANTING DETAIL3' MIN.* ALL PALMS TO HAVE CLEAR WOOD INDICATED ABOVEUNLESS OTHERWISE SPECIFIED.PALM HEIGHT/TRUNKSPECIFICATIONSOVERALL HEIGHT(OA):HIGHEST POINT IN THE CANOPY MEASURED FROM THESOIL LINE TO THE NATURAL POSITION OF THE LAST FULLYEXPANDED LEAF. UNLESS SPECIFIED DIFFERENTLY, THETERM HEIGHT, OR HEIGHT MEASUREMENTS SPECIFIED,WILL BE CONSIDERED OVERALL HEIGHT.CLEAR TRUNK(CT):A MEASUREMENT FROM THE SOIL LINE TO A POINT IN THECANOPY WHERE THE TRUNK CALIPER BEGINS TO TAPERABRUPTLY. ON MANY PALMS, THIS POINT WILL LIE AT THEBASE OF THE PETIOLE OF THE THIRD OR FOURTHYOUNGEST BUT FULLY EXPANDED LEAF.CLEAR WOOD(CW):A MEASUREMENT FROM THE SOIL LINE TO THE HIGHESTPOINT OF THE TRUNK FREE OF PERSISTENT LEAF BASES.ON PALMS WITH A CROWN SHAFT, THE MEASURE WILL BEFROM THE SOIL LINE TO THE BASE OF THE CROWN SHAFT.IT SHOULD BE NOTED THAT PALMS WITH VERYPERSISTENT LEAF BASES MAY NOT HAVE CLEAR WOOD.DPI INSPECTIONNOTES(REQUIRED)D.P.I. PALM INSPECTION NOTE:ALL PALMS SHALL HAVE A VALID ANDCURRENT STATE OF FLORIDA, DIVISION OFPLANT INDUSTRY (DPI) INSPECTIONCERTIFICATION PRIOR TO BEINGTRANSPORTED TO THE CONSTRUCTIONSITE. THE DPI CERTIFICATION MUST BESUBMITTED TO CPH AND A COPY OF THISCERTIFICTION MUST BE PROVIDED TO THEGENERAL CONTRACTOR AND MAINTAINEDWITH THE CONSTRUCTION RECORDS.D.P.I. INSPECTION OF ALL PLANTMATERIAL:ALL TREES, SHRUBS AND SOD WILL HAVE AVALID AND CURRENT STATE OF FLORIDA,DIVISION OF PLANT INDUSTRY (DPI)INSPECTION CERTIFICATION PRIOR TOBEING TRANSPORTED TO THECONSTRUCTION SITE. THE DPICERTIFICATION MUST BE SUBMITTED TOCPH AND A COPY OF THIS CERTIFICATIONMUST BE PROVIDED TO THE GENERALCONTRACTOR AND MAINTAINED WITH THECONSTRUCTION RECORDS.MULTI-TRUNK CONTAINER TREE PLANTING DETAILSPREADNTSHEIGHTCLEAR TRUNK (C.T.)OVERALL (O.H.)HEIGHT3"12"1' MIN1/2" NYLON STRAP4 INCH DEEP SAUCERUNDISTURBED SUBSOILBACKFILL MIX8' LODGE POLECUT CIRCULAR ROOTS4 INCHES MULCH - MAINTAIN 3-4INCHES CLEAR RADIUS AROUNDTRUNKROOT BALL MIN. 3 INCHES ABOVEGRADEPHASE 1OVERALL HEIGHTCLEAR TRUNKCLEAR WOODBUDMATRIX D PALMDATE PALMDPI INSPECTION NOTES(REQUIRED)D.P.I. PALM INSPECTION NOTE:ALL PALMS SHALL HAVE A VALID AND CURRENTSTATE OF FLORIDA, DIVISION OF PLANT INDUSTRY(DPI) INSPECTION CERTIFICATION PRIOR TO BEINGTRANSPORTED TO THE CONSTRUCTION SITE. THEDPI CERTIFICATION MUST BE SUBMITTED TO CPHAND A COPY OF THIS CERTIFICATION MUST BEPROVIDED TO THE GENERAL CONTRACTOR ANDMAINTAINED WITH THE CONSTRUCTION RECORDS.DPI INSPECTION NOTES(REQUIRED)D.P.I. INSPECTION OF ALL PLANT MATERIAL:ALL TREES, SHRUBS AND SOD WILL HAVE A VALIDAND CURRENT STATE OF FLORIDA, DIVISION OFPLANT INDUSTRY (DPI) INSPECTIONCERTIFICATION PRIOR TO BEING TRANSPORTEDTO THE CONSTRUCTION SITE. THE DPICERTIFICATION MUST BE SUBMITTED TO CPH ANDA COPY OF THIS CERTIFICATION MUST BEPROVIDED TO THE GENERAL CONTRACTOR ANDMAINTAINED WITH THE CONSTRUCTION RECORDS.Four (4) foot high 14.5 guage wire 2"x2" mesh fencing shall be installed encompassing the drip line of each tree, or one foot indiameter for each inch of trunk diameter, whichever is greater. When surveyed fencing shall be moved to the edge of the treeprotection area (TPA) as indicated on plans and be maintained through completion of construction.Landscaping within TPA shall not disturb existing soil profiles. Eight inches of potting soil shall be imported and evenly spread toprovide a planting medium within TPA.Pruning shall be completed under direct observation by the Designated Forester of CPH Engineers, Inc. or owner designated ISAcertified arborist and be accomplished by an arborist with five years or more experience pruning live oaks to ISA standards. Arboristmust obtain approval from the owner prior to commencement of pruning activities. Two week advance notification is required.Saved trees shall be pruned to remove dead and damaged wood, correct structural defects and to provide access and visibility.Utility lines and/or irrigation lines shall not occur within the TPA.Roto-tilling, disking, root raking or other clearing methods that disturb the soil profile are expressly prohibited.Brush and weeds occuring within the TPA shall be cleared by hand or utilizing only the mower of a light wheeled farm tractor (lessthan 60 hp). During such activities soil profiles shall not be disturbed.Grade changes shall not occur within the TPA. No fill shall be added, removed or stored within the TPA with exception of prescribedpotting soil (see item 10).All equipment and/or materials are prohibited within the TPA. Including but not limited to cement wash-out, chemicals, fuel orequipment servicing.Where the TPA occurs within 10 feet of the tree trunk, a trenching device shall be used to sever tree roots. Root raking shall notoccur before roots have been cleanly severed.8.9.10.1.6.7.5.4.2.3.TREE PROTECTION NOTES:STEEL TEE POST W/ CAPSWIRE MESH W/ TWISTED WIREDRIVE INTO GROUND, 6' O.C. (ATTACHDRIPLINE OF TREE IS THE EXTENT OF ITS LIMITS6' TYP.2' ORANGE FLAGGING TAPE@ 30" O.C.TREE PROTECTION DETAILN.T.S.4' H, 14.5 GAUGE WIRE MESHFENCE, 2" X 2" MESH,INSTALLED AT @ TREEDRIPLINE1LANDSCAPE NOTES:1. The landscape Contractor shall be responsible for all materials and all work as called for on the Landscape Plans and in the LandscapeSpecifications. In the event of variation between quantities shown on plant list and the plans, the plans shall control. The LandscapeContractor shall verify all quantities and report any discrepancies at the time of bidding.2. The Landscape Contractor shall review architectural/engineering plans and become thoroughly familiar with surface and subsurface utilities.3. Prior to construction, the contractor shall be responsible for locating all underground utilities and shall avoid damage to all utilities during thecourse of the work. Locations of existing buried utility lines shown on the plans are based upon best available information and are consideredto be approximate. It shall be the responsibility of the contractor 1) to verify the locations of utility lines within and adjacent to the work area 2)to protect all utility lines during the construction period 3) to repair any and all damage to utilities, structures, site appurtenances, etc. whichoccurs as a result of the construction 4) To field adjust the location of proposed trees and palms 10' off the center of the utility lines. Notify theLandscape Architect if a 10' offset does not function.4. The work shall be coordinated with other trades to prevent conflicts. Coordinate the planting with the irrigation work to assure availability andproper location of irrigation items and plants.5. Contractor shall ensure that there are no visual obstructions to vehicle lines of sight and traffic controls. Contractor shall field adjust treeand/or large shrub locations to avoid any such obstructions.6. Trees shall be maintained by the owner to avoid future such obstructions by pruning trees and/or shrubs as necessary utilizing horticulturallysound techniques.7. All planting shall be performed by personnel familiar with planting procedure and under the supervision of a qualified planting foreman.8. All plant material shall be graded Florida No. 1 or better as outlined under Grades and Standards for Nursery Stock, Part I and II, publishedby the Florida Department of Agriculture and Consumer Services.9. The Landscape Architect or Owner shall have the right, at any stage of the operations, to reject any and all work and materials which, in hisopinion, do not meet with the requirements of these specifications.10. Except as otherwise specified, the Landscape Contractor's work shall conform to accepted horticultural practices as used in the trade.11. The minimum acceptable size of all plants, measured after pruning, with branches in normal positions, shall conform to the measurementsspecified on the plant list or as indicated on the landscape drawing. Height and spread dimensions refer to main body of the plant and notextreme branch tip to tip. Trunk caliper (trunk diameter) is measured 6 inches from the ground on trees up to and including 4 inches in caliper,and 12 inches from the ground for larger trees. Since trunks are seldom round, the average of the largest diameter and that perpendicular toit is referred to as caliper.12. Plants shall be protected upon arrival at the site, by being thoroughly watered and properly maintained until planted.13. All tree pits shall be excavated to size and depth in accordance with the Florida Grades & Standards for Nursery Stock, unless shownotherwise on the drawings, and backfilled with the specified planting soil. The Landscape Contractor shall test fill all tree pits with waterbefore planting to assure proper drainage percolation is available.14. The Landscape Contractor shall be responsible for proper watering of all plants. All plants shall be thoroughly watered at time of planting andkept adequately watered until time of acceptance. It shall be the Landscape Contractor's responsibility to assure that plants are not overwatered.15. It shall be the Landscape Contractor's responsibility to prevent plants from falling or being blown over, to re-straighten and replant all plantswhich lean or fall and to replace all plants which are damaged due to lack of proper guying or staking. The Landscape Contractor shall belegally liable for any damage caused by instability of any plant material.16. All Palms to be staked as indicated per Palm staking details. All other trees to be stabilized utilizing 8' lodge poles per tree planting details.17. Plants blown over by high winds, within the guaranteed period, shall not be cause for additional expense to the Owner, but shall be theresponsibility of the Landscape Contractor. Damaged plants shall be replaced by the Landscape Contractor at no additional cost to theOwner.18. Sod shall be of a species specified on the drawings and originate from a commercial turf grower. It shall be a dense stand of live turf,reasonably free of weeds, well matted with grass roots in rectangles 12 inch by 24 inch or in 12 inch wide rolls in a length consistent with theequipment and methods used to handle the rolls and place the sod. Any netting contained within the sod shall be certified by themanufacturer to be bio-degradable. The soil and root mat shall be a minimum of 1-1/2 inch thick and must hold together during placement. Sod shall be place adjacent to one another to avoid gaps and overlaps. Joints shall be staggered between the rows. Sod placed on slopesexceeding 3:1 shall be pinned with turf staples. Sod turf, shall have been mowed a minimum of one week prior to cutting and delivery, sothat the length of the turf is no longer than 4 inches at time of delivery. Place sod within 48 hours of cutting the sod. The sod shall be keptmoist throughout the 48 hour period to maintain the health and viability of the sod. Submit a letter of certification to the Owner's CEIRepresentative, at time of delivery, as to the source of the sod, the time it was cut, the species and cultivars provided, last mowing date, andthat the sod is free of fire ants. Sod which has been cut for longer than 48 hours after being cut shall not be used unless specificallyauthorized by Owner's CEI Representative.19. It shall be the Contractor's responsibility to measure and determine the exact quantity of sod required for a complete job at the time of biddingor providing a price quote. The Owner shall not be responsible for additional cost due to the Contractor's under estimating of the quantity ofsod for the original bid area.20. The Landscape Contractor shall insure adequate vertical drainage in all plant beds, planters, and sod areas. Vertical drilling through anycompacted fill to native soil shall be accomplished to insure drainage. If well drained fill is necessary to assure positive drainage, this issueshall be brought up by the Landscape Contractor at time of bidding.21. The Landscape Contractor shall insure that his work does not interrupt established or projected drainage patterns.22. The Landscape Contractor shall prune, shape and remove dead foliage/limbs from existing plant material to remain. Confirm with theLandscape Architect or Owner the extent of work required at time of Bidding.23. Mulch - All plant beds shall be top dressed with 4" shredded hardwood mulch (or approved equal).24. Transplanted Material - The Landscape Contractor shall be responsible for determining and evaluating which plant materials are suitable fortransplanting and shall verify this with the Landscape Architect or Owner. The Landscape Contractor shall take all reasonable, horticulturallyacceptable measures to assure the successful transplanting of determined plant materials. The Landscape Contractor shall be responsiblefor replacing any relocated plant materials which die if such measures are not taken, as determined by the Landscape Architect or Owner.Replacement plants shall be of identical species and size if required.25. MAINTENANCE PRIOR TO FINAL INSPECTION AND ACCEPTANCE:Maintenance shall commence after each plant is planted and the maintenance period shall continue until the job or specific phase of the jobis accepted by the Landscape Architect or Owner. Extreme care shall be taken to instruct the Owner or his representatives in generalmaintenance procedures.Plant maintenance shall include watering, pruning, weeding, cultivating, mulching, tightening, and repairing of guys, replacement of sick ordead plants, resetting plants to proper grades or upright positions and restoration of the planting saucer and all other care needed for propergrowth of the plants.During the maintenance period and up to the date of final acceptance, the Landscape Contractor shall do all seasonal spraying and/ordusting of trees and shrubs. Upon completion of all planting, an inspection for acceptance of work will be held. The Landscape Contractorshall notify the Landscape Architect or Owner for scheduling of the inspection 10 days prior to the anticipated date.At the time of the inspection, if all of the materials are acceptable, a written notice will be given by the Landscape Architect or Owner to theLandscape Contractor Stating the date when the Maintenance Period ends.GUARANTEE AND REPLACEMENT:All plant materials shall be guaranteed for one (1) year from the time of final inspection and interim acceptance shall be alive and insatisfactory growth for each specific kind of plant at the end of the guaranteed period.At the end of the guarantee period, any plant required under this contract that is dead or not in satisfactory growth, as determined by theOwner or the Landscape Architect, shall be removed and replaced. Replacement plants shall have an extended guarantee, as noted above,from time of replacement.All replacements shall be planted of the same kind and size as specified on the plant list. They shall be the responsibility of the LandscapeContractor.26. TOPSOILTopsoil shall be natural, friable, fertile, fine loamy soil possessing characteristics of representative topsoil in the vicinity that produces heavygrowth. Topsoil shall have a pH range of 5.5 to 7.4, free from subsoil, objectionable weeds, litter, sods, stiff clay, stones larger than 1-inch indiameter, stumps, roots, trash, toxic substances, or any other material which may be harmful to plant growth or hinder planting operations.Top soil shall contain a minimum of three percent organic material.27. UNSUITABLE SUBSOILSLocations containing unsuitable subsoil shall be treated by one or more of the following:A. Where unsuitability is deemed by Owner or Owner's Representative to be due to excessive compaction caused by heavyequipment and where natural subsoil is other than AASHTO classification of A6 or A7, loosen such areas with spikes,discing, or other means to loosen soil to condition acceptable to Owner. Loosen soil to minimum depth of 12 inches withadditional loosening as required to obtain adequate drainage. Contractor may introduce peat moss, sand, or organicmatter into the subsoil to obtain adequate measures shall be considered as incidental, without additional cost to Owner.B. Where unsuitability is deemed by Owner or Owner's Representative to be due to presence of boards, mortar, concrete,graded aggregate base, or other construction materials in sub grade and where natural subsoil is other than AASHTOclassification of A6 or A7, remove debris and objectionable material. Such remedial measures shall be considered asincidental, without additional cost to Owner.C. Where unsuitability is deemed by Owner to be because natural subsoil falls into AASHTO classification of A6 or A7 andcontains moisture in excess of 30 percent, then installation of sub drainage system or other means described elsewhere inSpecifications shall be used. Where such conditions have not been known or revealed prior to planting time and they havenot been recognized in preparation of The Drawings and Specifications, then Owner shall issue pricing order to installproper remedial measures.D. Planting beds where existing subsoil is determined by Owner to be unsuitable for plant growth in accordance paragraphUnsuitable Subsoil herein shall be excavated to a depth of 12 inches or as needed to provide adequate drainage. Replaceexcavated soil with planting soil.CONFORMED SET61
L1
RK1 RED KNOCKOUT ROSEROSA 'KNOCKOUT'3 GAL., 15" MIN. HT., 12" SPRD., 30" O.C.40LI CRAPE MYRTLELAGERSTROEMIA INDICA 'DYNAMITE'65 GAL., 3.5" CAL. MIN.,8' MIN. HT., 4' SPRD., STD TRUNK, 20' O.C. 121CH EUROPEAN FAN PALMCHAMAEROPS HUMILIS65 GAL., 5'-6' OA15LC DWARF RUBY LOROPETALUM LOROPETALUM CHINENSIS 'RUBY'7 GAL., 14" MIN. HT., 14" SPRD., 36" O.C.85LJ1JAPANESE LIGUSTRUMLIGUSTRUM JAPONICUM65 GAL., 3.5" CAL. MIN., 8' MIN. HT., 4' MIN. SPRD.12NOTES - PHASE 11. PLANT DESCRIPTIONS ARE FOR MINIMUM ACCEPTABLE SPECIFICATIONS. ALL CRITERIA LISTED FOR CONTAINER SIZE, CALIPER, HEIGHT, SPREAD, ETC.MUST BE MET FOR PLANT MATERIAL ACCEPTANCE. FOR EXAMPLE, IF A THREE GALLON SHRUB DOES NOT MEET THE HEIGHT OR SPREADSPECIFICATION, IT WILL NOT BE ACCEPTED.2. IF SPECIFIED PLANTS ARE UNAVAILABLE AT TIME OF CONSTRUCTION, CONTRACTOR MAY REPLACE SPECIFIED PLANTS WITH PLANTS APPROVED BY THELANDSCAPE ARCHITECT.3. ALL OPEN SPACE AREAS WITHIN THE PROPERTY SHALL BE SODDED UNLESS PAVED, SEEDED AND MULCHED OR PLANTED WITH SHRUBS AND GROUNDCOVER..4. ALL LANDSCAPED AREAS WILL BE 100% IRRIGATED WITH A CENTRAL AUTOMATIC IRRIGATION SYSTEM INCLUDING A RAIN SENSOR.5. CONTRACTOR TO MODIFY EXISTING IRRIGATION SYSTEM TO INSURE ADEQUATE IRRIGATION FOR ALL NEW PLANT MATERIAL.6. CONTRACTOR SHALL REPLACE ANY EXISTING SOD OR OTHER PLANT MATERIALS DAMAGED DURING CONSTRUCTION IN AREAS THAT ARE OUTSIDEPROPOSED LANDSCAPE AS SHOWN ON THE PLAN.TREESPLANT LIST - PHASE 1SYM. COMMON NAMEBOTANICAL NAMEDESCRIPTIONQTYSP SABAL PALMSABAL PALMETTOB/B, 12' MIN. OVERALL HT., REGENERATED HEADS, BOOTED47IV DWARD YAUPON HOLLYILEX VOMITORIA 'NANA'7 GAL., 12" MIN. HT., 24" SPRD., 30" O.C.97VOSWEET VIBURNUMVIBURNUM ODORATISSIMUM7 GAL., 30" MIN. HT., 36" O.C.291SOD ST. AUGUSTINE GRASS STENOTAPHRUM SECUNDATUM SOLID SOD, CONTRACTOR TO VERIFY QTY.SM DWARF SABAL PALMETTO SABAL MINOR 'BLUE STEM'7 GAL., 18-20" MIN. HT., 18" MIN. SPRD. 4' O.C.248PX XANADUE PHILODENDRONPHILODENDRON XANADUE3 GAL., 12" MIN., 12" SPRD., 36" O.C.515TA TRICOLOR JASMINETRACHELOSPERMUM ASIATICUM 'ANGYO'1 GAL., FULL, 10" O.C.4871AA LILY OF THE NILEAGAPANTHUS AFRICANUS3 GAL., FULL., 24" O.C.374LCDWARF RUBY LOROPETALUM LOROPETALUM CHINENSIS 'RUBY'7 GAL., 14" MIN. HT., 14" SPRD., 36" O.C.364GROUNDCOVERCV LIL JOHN BOTTLE BRUSHCALLISTEMON VIMINALIS3 GAL., 12" MIN., 12" SPRD., 36" O.C.222SR ORANGE BIRD OF PARADISE STRELITZIA REGINAE15 GAL., 36" MIN. HT., 5 PPP67SHRUBS LI1 CRAPE MYRTLELAGERSTROEMIA INDICA 'DYNAMITE'65 GAL., 3.5" CAL., 8' MIN. HT., 4' SPRD., MULTI TRUNK, 20' O.C. 5SNWHITE BIRD OF PARADISESTRELITZIA NICOLAI 25 GAL., 6' MIN. HT., FULL12TS DWARF OYSTER PLANTTRADESCANTIA SPATHACEA 'DWARF'1 GAL., FULL, 18" O.C.347DT VARIEGATED BLUEBERRY FLAX LILY DIANELLA TASMANICA1 GAL., 14" HT., 16" MIN., 24" O.C.178PSA WHITE FOUNTAIN GRASSPENNISETUM SETACEUM 'ALBA'3 GAL., FULL, 36" O.C.160AZ VARIEGATED SHELL GINGER ALPHINIA ZERUMBET VARIEGATA3 GAL., FULL., 3PPP, 30" O.C.60MC MUHLY GRASSMUHLINBERGIA CAPILLARIS3 GAL., FULL, 36" O.C.508MC1 MUHLY GRASSMUHLINBERGIA CAPILLARIS4" POT, FULL, 36" O.C.3634ZP COONTIEZAMIA PUMILA3 GAL., FULL, 24" O.C.629TD DWARF FAKAHATCHEE GRASS TRIPSACUM DACTYLOIDES4" POT, FULL, 36" O.C.2830PC CANARY ISLAND DATE PALM PHOENIX CANARIENSISB/B.,12' MIN. CLEAR TRUNK HT., CLASSIC CUT8LN NATCHEZ CRAPE MYRTLELAGERSTROEMIA 'NATCHEZ'65 GAL., 3.5" CAL., 8' MIN. HT., 4' SPRD4J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 LSP.dwg Jun 15, 2017 - 1:33pm dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014LANDSCAPE PLANT LISTPHASE 11"=10'Key MapSCALE: 1"= 10'510 200LANDSCAPE AREA 1SCALE: 1" = 10'PHASE 1LANDSCAPE AREA 1Know what'sR1CONFORMED SET62
R=5'7°5.0'14.2'EXISTING MONUMENTRELOCATED TO THISLOCATION7.3'AIRLINE AVE.PROPOSED EXPANSIONJOINT TYP.PROPOSED SCORE JOINT TYP.EXISTINGPARKING GARAGET3PROPOSED TRASHRECEPTACLE WITHCOVER ON A 2.5'X2.5' PADPROPOSED PAVER38.6'13.3'PROPOSED EXPANSIONJOINT TYP.PROPOSED EXPANSIONJOINT TYP. 1REFER TO CIVIL FORSIDEWALK CONSTRUCTION. 3 2PROPOSEDFLAG POLE1 4/5SITE BENCHMARK # 2 L1
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 HSP.dwg Jun 15, 2017 - 9:07am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014HARDSCAPE PLANPHASE 11"=10'Key MapPHASE 1HARDSCAPE AREA 1SCALE: 1"= 10'5102001HARDSCAPE AREA 1SCALE: 1" = 10'Know what'sRCONFORMED SET63
WEED BARRIER - 10 MIL THICKNESSAPPLY TO ALL SIDES AND BOTTOM3" SEMINOLE CHIPS FLUSH WITHTOP OF CURBREFER TO CIVIL DETAILS FOR BACKFILLREQUIREMENTSCURB TYP.J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 HSP.dwg Jun 15, 2017 - 9:09am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014 HARDSCAPE DETAILSPHASE 1NTSRIBBON CURB, 6" WIDE X 12" DEEP, 3,500 PSIWITH LIGHT BROOM FINISH, AS PER PLANSUNIT PAVERS1" SAND BEDDINGFILTER FABRICSCALE: NTS#4 REBAR (2) TYP.APAVER DETAILSWALKWAY1" SAND BEDDINGEXPANSION JOINTBASE REFER TO CIVIL PLANSMIN. 4" AGGREGATED BASE TO 95% STANDARDLABORATORY TESTING IN ALL PAVER AREAS,REFER TO THE CIVIL PLANS FOR BASE INEMPLOYEE BREAK AREA3PHASE 1 HARDSCAPE AREA 1 - FLAG POLEPAVER NOTE:PHASE 1 HARDSCAPE AREA 1 - FLAGPOLEPAVESTONE, VERONA SERIES II, 24" X 5" X 3 15/16", RUNNINGBOND PATTERN, COLOR BY OWNER, (OR APPROVED EQUAL)CB FLAGPOLEFLAGPOLE FOUNDATION DETAILSCALE: NTSAB COMMERCIAL FLAGPOLEMANUFACTURER: LIBERTY FLAGPOLE COMPANY (OR APPROVED EQUAL)MODEL: IWW40D81-02, 40' TAPERED ALUMINUM INTERNAL HALYARDSLEEVE: 4'BUTT DIA.: 8"TOP DIA.: 4"WALL THICKNESS: .188GROSS WEIGHT: 34724. SAW CUT JOINTS WITHIN 24 HOURS.3. CONTRACTION JOINTS MAXIMUM DISTANCE = 21', SAW CUT 2" DEEP AND FILL WITH HOT POURED SEALER.2. EXPANSION JOINTS MAXIMUM DISTANCE = 100', USED 3/4"x4" PREMOLDED EXPANSION MATERIAL.1. 3/4"x4" PREMOLDED EXPANSION MATERIALS AROUND P.P. OR OTHER STRUCTURES IN WALK.NOTES:PLANTOOLED JOINTS REFERTO HARDSCAPE PLANSFOR SPACINGSCALE: NTSCONCRETE SIDEWALK JOINTS DETAILVARIESREFER TOHARDSCAPEPLANSVARIESREFER TO CIVIL CONCRETE SIDEWALKREFER TO CIVIL1CONTINUE CONCRETE SIDEWALK /SLAB SECTION THROUGH 14" X 14"CONCRETE SLAB FOR BOLLARDINSTALLATION. CENTER BOLLARDON SLAB.SCALE: NTSSTONE AND WEED BARRIER PLACEMENT DETAIL6SCALE: NTSNOTES:T2 = DUMOR INC., (OR APPROVED EQUAL)1. MODEL 196-32-FTO,32 GALLON, COLOR BY OWNER, RC COVER T3= DUMOR INC., (OR APPROVED EQUAL)2. MODEL 196-32-FTO 32 GALLON, BT COVERCOLOR BY OWNER,3. ATTACH WITH EXPANSION BOLTS.TRASH RECEPTACLE DETAIL4" P.C. CONCRETE4"SCALE: NTSTRASH RECEPTACLE ON CONCRETEPAD DETAILNOTE:1. SEE HARDSCAPE PLAN FOR DIMENSIONS PERTAINING TO PAD SIZEDIFFERENT RECEPTACLES REQUIRED A DIFFERENT PAD SIZE.2. MINIMUM 3,000 PSI CONCRETE REQUIRED.STAINLESS STEELANCHOR BOLT W/EXPANSION SHIELD 3"INTO CONCRETE PAD451CONFORMED SET64
GENERATORGENERATORSAIRLINE AVENUESEXISTING IRRIGATION VALVEEXISTING IRRIGATION MAINAPPROX. LOCATIONEXISTING IRRIGATION VALVEAPPROX. LOCATIONEXISTING IRRIGATION VALVEEXISTING OAK TO BE REMOVEDPROPOSED SEMINOLE CHIPSAPPLIED AT A 3" DEPTHPROPOSED SITE L
IGHT
TYP
.EXISTING OAK WITH TREEPROTECTION TO REMAIN
EXISTING OAK WITH
TREEPROTECTION
TO REMAI
N EXISTING OAK WITH TREEPROTECTION TO REMAINPROPOSED SEMINOLE
CHIPSPROPOSED SEM
INOL
E CHIPS PROPOSED SEMINOLE CHIPSAPPLIED
AT A
3" DEPTHPROPOSED CONCRETE WALLREFER TO C
IVIL PLANS FO
R
DETAIL AND SPECIFICATIONS6''3''3''3''3''6''6''6''8''8''3''8''8''8''3''3''8''8''8''8''6''3''8''8''8''6''8''3''3''8''8''8''MATCH
LI
N
E
I
1.
0
6MATCHLINE I1.02MATCHLINE I1.01MATCHLINE I1.03MATCHLINE I1.02MATCHLINE I1.04MATCHLINE I1.03MATCHLINE I2.00MATCHLINE I1.04MATCHLINE I1.05MATCHLINE I2.00MATCHLINE I1.06MATCHLINE I1.06J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:10am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014OVERALL IRRIGATION PLANPHASE 11"=100'SCALE: 1"= 100'50 1002000Know what'sR1I1.00I1.01I1.02I1.03I1.04I1.05I1.06I1.07I1.08HANGAR RD.AIRLINE AVE.AIRPORT RD.CONFORMED SET65
GENERATOR 66''MATCH
L
I
N
E
I
1
.
0
6
SITE BENCHMARK # 2 L1
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:11am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510200IRRIGATION AREA 1SCALE: 1" = 10'PHASE 1IRRIGATION AREA 1Know what'sR1AIRLINE AVENUECONFORMED SET66
SITE BENCHMARK # 2L1EXISTING IRRIGATION MAINAPPROX. LOCATIONMATCHLINE I1.02MATCHLINE I1.01J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 1:39pm dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1IRRIGATION AREA 2IRRIGATION AREA 2SCALE: 1" = 10'1RED CLEVELAND BLVD.CONFORMED SET67
SITE BENCHMARK # 2 L1
EXISTING IRRIGATION MAINAPPROX. LOCATIONEXISTING IRRIGATION MAINAPPROX. LOCATIONMATCHLINE I1.01MATCHLINE I1.03C .02J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:11am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1IRRIGATION AREA 3IRRIGATION AREA 3SCALE: 1" = 10'1RED CLEVELAND BLVD.CONFORMED SET68
SITE BENCHMARK # 2 L1
8''MATCHLINE I1.02MATCHLINE I1.04J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:12am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1IRRIGATION AREA 4IRRIGATION AREA 4SCALE: 1" = 10'1RED CLEVELAND BLVD.CONFORMED SET69
SITE BENCHMARK # 2 L1
8''MATCHLINE I1.04MATCHLINE I1.03MATCHLINE I2.00J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:12am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1IRRIGATION AREA 5IRRIGATION AREA 5SCALE: 1" = 10'1RED CLEVELAND BLVD.CONFORMED SET70
SITE BENCHMARK # 2 L1
8''8''3''EAINSTALL 34'' PVC PIPING FROM VALVE #B-16,COMMON, TO ALL TREE SPRAYS NEAR THEENTRANCE (10 EA.)DO NOT CONNECT TO ANY OTHER PIPING.PROGRAM THIS VALVE TO OPERATECONCURRENTLY WITH OTHER VALVES.8''CONNECT CONTROLLER TOWIRING TO EXISTING VALVES ANDASSIGN STATIONS TO THOSEVALVES AFTER THE NEWLYINSTALLED VALVES'PROGRAMMING.PROGRAM A MAXIMUM OF 75 GPMON CONTROLLER ''A'' AT ANY TIME.MATCHLINE I2.00J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:12am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=10'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1 IRRIGATION AREA 6IRRIGATION AREA 6SCALE: 1" = 10'1RED CLEVELAND BLVD.AIRLINE AVENUECONFORMED SET71
SITE BENCHMARK # 2 L1
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:13am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=30'Key MapSCALE: 1"= 30'15 30600Know what'sRPHASE 1IRRIGATION AREA 7IRRIGATION AREA 7SCALE: 1" = 30'1AIRLINE AVENUECONFORMED SET72
SITE BENCHMARK # 2 L1
J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:13am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=30'Key MapSCALE: 1"= 30'15 30600Know what'sRPHASE 1IRRIGATION AREA 8IRRIGATION AREA 8SCALE: 1" = 30'1AIRLINE AVENUEAIRPORT ROADCONFORMED SET73
SITE BENCHMARK # 2 L1J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:14am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION PLANPHASE 11"=30'Key MapSCALE: 1"= 10'510 200Know what'sRPHASE 1 IRRIGATION AREA 9IRRIGATION AREA 9SCALE: 1" = 10'1SEE MATCH LINE ABOVESEE MATCH LINE BELOWAIRLINE AVENUECONFORMED SET74
LRSLRSPEJ:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:14am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION LEGENDPHASE 1NTSKnow what'sRIRRIGATION LEGEND1CONFORMED SET75
2SCALE: N.T.S.5SCALE: N.T.S.6SCALE: N.T.S.7SCALE: N.T.S.TO LATERAL LINEADJUST THE VERTICAL ORIENTATION OF SPRINKLERS ON SLOPES TO PROVIDE UNIFORM COVERAGE OF THESLOPED AREA.IRRIGATION HEADS SHALL BE LOCATED MINIMUM ONE (1) FOOT FROM ANY WALL, COLUMN, OR BUILDINGEDGE/FACE.IRRIGATION HEADS SHALL BE DIRECTED AWAY FROM BUILDING AT ALL TIMES, SO THAT SPRAY DOES NOT HITBUILDING FACE, COLUMN, WALL, ETC.ANY EXISTING TREE ROOTS, WHEN ENCOUNTERED DURING INSTALLATION OF UTILITIES, SHALL BE CUT OFF EVENLYWITH CLEAN SHARP PRUNING TOOLS AND COVERED WITH SOIL AS SOON AS POSSIBLE TO REDUCE DEHYDRATION.THE CONTRACTOR/DEVELOPER SHALL MINIMIZE THE DAMAGE TO EXISTING TREE ROOT SYSTEMS.PROVIDE HAND WATERING FOR ESTABLISHMENT PERIOD FOR ALL TREES NOT LOCATED IN IRRIGATED AREAS ORTHAT DO NOT HAVE BUBBLERS INSTALLED AT THOSE TREES.CONSULT WITH THE OWNER AS TO LOCATIONS OF THIS SYSTEM'S INSTALLATION AS RELATED TO THE FUTURE PHASEOF THIS PROJECT TO MINIMIZE IMPACT ON THIS SYSTEM DURING THE FUTURE PHASES OF CONSTRUCTION.INSTALL MARLEX STREET ELLS FOR ALL HEADS ON RISERS AND ALL SPRINKLERS IN TURF.INSTALL ALL OTHER SPRINKLERS WITH FUNNY PIPE AND SBE-050 FITTING.ALL IRRIGATION HEADS IN SHRUBS/GROUNDCOVER AREAS SHALL BE INSTALLED ON RISERS. SEE DETAILS BELOW.1SCALE: N.T.S.NOTESINSTALL ALL PIPING SHOWN BETWEEN DIFFERENT PIPE SIZES AS THE LARGER SIZED PIPE.INSTALL ALL PIPING TO INDIVIDUAL HEADS AS 3/4''.INSTALL PIPING BETWEEN THE LAST MARKED PIPE AND PIPING TO INDIVIDUAL HEADS (WHERENO OTHER MARKINGS SHOW) AS THE LAST MARKED PIPE SIZE.ANY IRRIGATION ITEMS NORMALLY INSTALLED IN LANDSCAPE AREAS THAT ARE SHOWNOUTSIDE OF LANDSCAPE AREAS OR OUTSIDE OF THE PROPERTY LINES ARE SHOWN AS SUCHFOR GRAPHIC CLARITY ONLY. INSTALL THESE ITEMS INSIDE OF PROPERTY LINES AND INLANDSCAPE AREAS.THIS SYSTEM REQUIRES 70 GPM AT 60 PSI AT THE PUMP DISCHARGE LOCATIONS.. VERIFYGALLONAGE AND PRESSURES AND REPORT ANY DISCREPANCIES TO THE LANDSCAPEARCHITECT BEFORE COMMENCING WITH THE INSTALLATION.PROVIDE PROOF TO THE LANDSCAPE ARCHITECT THAT ALL AVAILABLEMAINTENANCE MANUALS FOR EACH OF THE PRODUCTS INCLUDED IN THIS INSTALLATION HAVEBEEN PROVIDED TO THE OWNER OR OWNER'S REPRESENTATIVE.ADJUST THE IRRIGATION SYSTEM COMPONENTS AND EXISTING SYSTEM TO PROVIDEUNIFORM COVERAGE. ASSURE THAT THE SYSTEM PROVIDES 100% COVERAGE OF ALLLANDSCAPE MATERIALS INCLUDING SHRUBS, GROUND COVER, TREES AND TURF.3SCALE: N.T.S.4SCALE: N.T.S.J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:14am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION DETAILSPHASE 1NTS1CONFORMED SET76
1SCALE: N.T.S.2SCALE: N.T.S.1/2" MARLEX STREET ELL.1/2" MARLEX STREET ELL.1/2"x 8" PVC SCH. 80 NIPPLE.1/2" MARLEX STREET ELL.SIDE INLET (DO NOT USE)RAINBIRD 1812 SAM SPRINKLERPVC SCH. 80 TEEPVC LATERAL LINE.MP ROTATOR NOZZLEFINISH GRADE.PVC SCH. 80 TEERAINBIRD 1806 SAM SPRINKLERMP ROTATOR NOZZLEFINISH GRADE.1/2" MARLEX STREET ELL.1/2" MARLEX STREET ELL.1/2"x 8" PVC SCH. 80 NIPPLE.1/2" MARLEX STREET ELL.PVC LATERAL LINE.(PURPLE FOR REUSE)(PURPLE FOR REUSE)5SCALE: N.T.S.4SCALE: N.T.S.3SCALE: N.T.S.'7N.T.S.6SCALE: N.T.S.CLCL123456789101112346789111251351310129SCALE: N.T.S.DISCHARGE PIPINGSUBMERSIBLE PUMP2 1/2'' CHECK VALVEWELL CASING (4'' )2 1/2'' GALV. 90 DEG. TEE2 1/2'' UNIONFOOT VALVECLA-VAL SOL ./ PR. RED. VALVEAND MOTORAIR RELIEF /VACUUM RELIEF VALVEFITTINGSAS NECESSARYJUNCTION BOXGALV. NIPPLEGALV. THREADED 45 DEG. ELLTHREADED GALV. PIPE18'' MIN.FINISHED GRADEGALV. THREADED 45 DEG. ELLSCH. 80 PVC NIPPLESCH. 80 3'' GASKET X2 1/2'' FPT ADAPTER3'' SCH. 40 MAIN LINEINSTALL PROPERLY SIZE LEMEUR(OR EQUAL) ENCLOSURE OVERPUMP AND CLA-VAL.8N.T.S.DRILL A 4'' DEEP WELL TO THE FLORIDAN AQUIFER CAPABLE OFPROVIDING 70 GPM AT A REASONABLE DEPTH (COMPARABLE TOTHE EXISTING WELLS).INSTALL 7.5 HP SUBMERSIBLE PUMPS CAPABLE OF PROVIDING 75GPM @ 60 PSI AT THE DISCHARGE INTO THE IRRIGATION SYSTEMAT EACH OF THE 3 WELL LOCATIONS.PROVIDE AND INSTALL ALL ITEMS NECESSARY FOR AUTOMATICOPERATION OF THE PUMPING SYSTEM THROUGHOUT THEIRRIGATION OPERATION CYCLE, INCLUDING A CLA-VALPRESSURE REDUCING VALVE, ALL PIPE, FITTINGS, STARTER,CONTROLS, WIRING, RACES, CONDUITS, BOXES CONNECTIONSAND ANY OTHER MISCELLANEOUS ITEMS.10SCALE: N.T.S.J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:14am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION DETAILSPHASE 1NTSIRRIGATION SYSTEM PERFORMANCE NOTESIRRIGATION SYSTEM AS SHOWN IS DESIGNED TO OPERATE FROM AWELL AND PUMPPROVIDING A MINIMUM FLOW OF 70 GPM AND A MINIMUM PRESSURE OF 60 PSI.1)CONTRACTOR SHALL CONTACT THE LANDSCAPE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION IF AVAILABLE FLOW AND PRESSURE DEVIATES FROM 709 GPM AND 60 PSI MORE THEN 5% AND WILL AFFECT THE PERFORMANCE OF THE SYSTEM.MINIMUM PRESSURE REQUIREMENTS - 60 PSI AT THE POINT OF CONNECTIONHEAD LAYOUT BASED ON BASE INFORMATION PROVIDED. HEADS SHALL BE ADJUSTED TO ACCOMMODATE FIELD VARIATIONS WHILE MAINTAINING 100% COVERAGE AND MINIMIZING OVERSPRAY ONTO PAVED AREAS AND BUILDINGS.2)LATERAL PIPE SHALL BE SIZED SO THE WATER VELOCITY DOES NOT EXCEED 5 FEET PER SECOND. MAXIMUM GPMPER PIPE SIZE AS FOLLOWS:3)3/4" PIPE SCHEDULE 401" PIPE 1 1/4" PIPE 1 1/2" PIPE 2" PIPE 2 1/2" PIPE 3" PIPE 8 GPM 13 GPM 22 GPM 30 GPM 50 GPM 75 GPM 110 GPM WATER SERVICE LINE, WATER METER, CHECK VALVES, SURGE PROTECTION, ETC.. AND PERFORMANCE OF THE WATER SOURCE ARE NOT A PART OF THESE DRAWINGS.4)30 PSI AT THE BASE OF THE POP-UP SPRAY HEADS1CONFORMED SET77
1SCALE: N.T.S.2SCALE: N.T.S.J:\S12014\Landscape\DWG\PreliminaryDesign\Plans\S12014 IRR.dwg Jun 15, 2017 - 9:14am dbryantDrawn by:Designed by:Approved by:Checked by:DateNo.12345Scale:Job No.:Date:6Sheet No. 2017RevisionBy7Architects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersStructuralSurveyorsTraffic / TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexas500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH ,Inc.MDSMDSDRBMDS10/07/15S12014IRRIGATION DETAILSPHASE 1NTS1CONFORMED SET78
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
BOS
BOS
BOS
BOS
BOS
BOS
XX
XXXXXXXX
XXXXXXXXBENCHBENCHBENCHBENCHBENCHBENCHBENCHBOCEOPBOCEOPBOCEOP
BOCEOPSTA
OR
INGNDLANE
FIRENO PARKING GENERATORBENCHBENCHEXISTING BAREXISTING RESTAURANTDRIVE
1-ELD-A1001EXISTING WELCOME CENTERNO WORKENTRANCE ROAD1-BC3-A1001EXISTING LOADING DOCKBAGGAGE CLAIM 3NEW FIRE RISER LOCATIONNEW FIRE SPRINKLER LOCATIONS - REFER TO FIRE PROTECTION DRAWINGS1-NIE-A1001EXISTING TERMINAL "A"EXISTING TERMINAL "B"BAGGAGE CLAIM 1 AND 2EXISTING PARKING DECKRELOCATE EXISTING STAIRSNEW FIRE DOORDEMOLITION PLAN LEGENDITEMS TO DEMOLISHITEMS TO REMAIN1. EXTENT OF DEMOLITION SHOWN HEREIN IS PROVIDED TO INDICATE THE GENERAL LOCATION AND NATURE OF REQUIRED DEMOLITION WORK. THESE DRAWINGS HAVE BEEN DEVELOPED FROM RECORD DRAWINGS AND WALK-THROUGH FIELD VERIFICATION AND MAY NOT REFLECT ALL EXISTING FIELD CONDITIONS. THE CONTRACTOR SHALL VERIFY THESE CONDITIONS AND NOTIFY THE ARCHITECT IN WRITING OF ANY INCONSISTENCIES BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS. DEMOLITION SHALL NOT BE LIMITED TO THE LIMITS OF CONSTRUCTION AS SHOWN IN THE DEMOLITION DRAWINGS.THE CONTRACTOR SHALL COORDINATE AND ADJUST THE LIMITS OF CONSTRUCTION AS NECESSARY TO ACCOMPLISH THE FINAL PRODUCT AS SHOWN THROUGHOUT THE CONSTRUCTION DOCUMENTS.2. CLEAN AND REMOVE ALL RESIDUES FROM SLAB IN PREPARATION FOR NEW FLOOR FINISH PER FLOOR FINISH PLAN. PROVIDE LEVELING MATERIAL COMPATIBLE WITH FINISH MATERIAL AND SURFACE GRINDING WHERE NECESSARY TO ATTAIN A SMOOTH AND LEVEL SURFACE FOR THE APPLICATION OF NEW FLOOR FINISH.3. PATCH AND REPAIR ALL EXISTING DAMAGED HOLES, OPENINGS ON ALL EXISTING WALLS. REMOVE ALL EXISTING MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT, DEVICES, HANGER'S AND FASTENERS, WHICH ARE DETERMINED TO BE ABANDONED. PATCH AND REPAIR ALL HOLES AND DAMAGE CREATED BY REMOVAL WITH SIMILAR ADJACENT MATERIALS.4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR REPLACEMENT OF ANY FIRE ASSEMBLIES DAMAGED DURING DEMOLITION OR CONSTRUCTION TO MEET ORIGINAL FIRE PROTECTION REQUIREMENTS.DEMOLITION GENERAL NOTES:5. DEMOLITION SHALL BE EXECUTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES.6. REFER TO MECHANICAL, ELECTRICAL. DRAWINGS FOR RELOCATION OF UTILITIES. USE CARE IN DEMO ABOVE CEILING, ALL COMMUNICATIONS CONDUIT AND SPARE CONDUIT TO REMAIN.7. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN ORNOT, AND PROTECT THEM FROM DAMAGE. CONTRACTOR SHALL BEAR ALL EXPENSE OFREPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BYOPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK.8. DEMOLITION/RESTORATION ITEMS MAY NOT BE ALL INCLUSIVE. CONTRACTOR SHALL REVIEW THE REQUIREMENTS OF NEW CONSTRUCTION AND COMPLETE ALL DEMOLITION/ RESTORATION, CUTTING AND PATCHING NECESSARY TO ACHIEVE INTENDED NEW CONDITION AND QUALITY.9. RELOCATION OF ANY ITEMS INVOLVED IN THE WORK IS SUBJECT TO THE CONTRACTOR'S ABILITY TO DO SO WITHOUT PERMANENTLY DAMAGING OR MARRING THE ITEMS TO BE RELOCATED. IF CONTRACTOR IS UNABLE TO RELOCATE ANY ITEM AS PRESCRIBED HEREIN, HE SHALL SUBSTITUTE NEW MATERIAL TO MATCH EXISTING. CONTRACTOR SHALL SAFELY STORE MATERIAL TO BE REUSED UNTIL TIME OF INSTALLATION.10. CONTRACTOR SHALL REMOVE ALL EXISTING FLOOR FINISHES WHERE NOTED ANDPREPARE SLAB TO RECEIVE NEW FLOOR FINISHES UNLESS NOTED OTHERWISE.11. CONTRACTOR SHALL PATCH AND REPAIR ALL WALL SURFACES TO REMAIN THAT ARE DAMAGED BY OPERATIONS IN CONJUNCTION WITH EXECUTION OF THE WORK AND RETURNED TO THEIR ORIGINAL CONDITION.12. DURING DEMOLITION, THE CONTRACTOR SHALL BRACE ALL EXISTINGSTRUCTURES TO MAINTAIN STRUCTURAL INTEGRITY. DO NOT CUT, MODIFY ORDAMAGE STRUCTURAL MEMBERS.13. SELECTIVE DEMOLITION MAY NOT BE INDICATED IN ALL AREAS WHERE IT MAY BENECESSARY TO DEMOLISH ALL OR PART OF AN EXISTING BUILDING COMPONENT TOGAIN ACCESS TO AREAS FOR TIE-IN TO BUILDING SYSTEMS, OR WHICH MAY BEREQUIRED TO INSTALL PROPOSED CONSTRUCTION INDICATED ON THE DRAWINGS.DEMOLITION FOR THESE PURPOSES SHALL BE DONE AT NO ADDITIONAL COST TO THEOWNER AND THE AREAS SHALL BE RETURNED TO THEIR ORIGINAL CONDITION ORPROPOSED CONDITION.14. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN THIS DEMOLITION ANDSHALL REPAIR AT HIS COST ANY ADJACENT CONDITIONS WHICH ARE DAMAGED AS ARESULT OF THIS DEMOLITION.15. PROTECTION: PERFORM DEMOLITION WITH THE LEAST IMPACT ON EXISTINGFACILITIES STILL IN USE, PROVIDE SUPPORT TO ALL STRUCTURAL MEMBERS. ERECTDUST BARRIERS TO ELIMINATE THE SPREAD OF DUST, FUMES OR SMOKE TOOCCUPIED AREAS.16. PROTECT ALL EXISTING FLOOR FINISHES (TILE, CARPET, ETC.) ADJACENT TODEMOLITION AREAS.17. AS A PART OF THIS PROJECT PROVIDE FOR PATCHING AND INFILL OF ALL EXISTINGNON-COMPLIANT OPENINGS AND PENETRATIONS IN RATED WALLS AND FLOORSEPARATIONS WITHIN THE LIMITS OF THE PROJECT AREA AND EXTENDING 5 FEETBEYOND THE PROJECT AREA IN ALL DIRECTIONS. PATCHING AND INFILL SHALL MATCHEXISTING RATED CONSTRUCTION AND MEET CODE REQUIREMENT FOR SEALING OFPENETRATIONS. 18. CONTRACTOR SHALL OBTAIN A COPY OF THE CURRENT UNDERWRITERS LABORATORIES, INC. FIRE RESISTANCE DIRECTORY, VOLUME 1 AND 2 AS A PART OF THIS PROJECT AND SHALL REFER THERETO FOR FULL REQUIREMENTS OF FIRE RATED CONSTRUCTION AND PENETRATIONS.19. DURING DEMOLITION AND CONSTRUCTION, PROTECT ALL ADJACENT AREAS FROM DAMAGE.20. ALL ITEMS INDICATED TO BE SAVED/STORED SHALL BE STORED OFF SITE AT CONTRACTORS OWN EXPENSE. THE CONTRACTOR SHALL BEAR ALL COSTS ASSOCIATED WITH THE REMOVAL, STORAGE, PROTECTION AND REPLACEMENT OF ALL SAID ITEMS FOR THE REINSTALLATION PER THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL ALSO BEAR ALL COSTS ASSOCIATED WITH THE REPLACEMENT OF ALL SAID ITEMS DAMAGED DURING DEMOLITION.21. CUT WORK BY METHODS LEAST LIKELY TO DAMAGE WORK TO BE RETAINED AND WORK ADJOINING. IN GENERAL, WHERE PHYSICAL CUTTING ACTION IS REQUIRED, CUT WORK WITH SAWING AND GRINDING TOOLS, NOT WITH HAMMERING AND CHOPPING TOOLS. CORE DRILL OPENINGS THROUGH CONCRETE WORK.22. PROTECTION: PROVIDE ADEQUATE PROTECTION OF OTHER WORK DURING SELECTIVE DEMOLITION TO PREVENT DAMAGE, AND PROVIDE PROTECTION OF THE WORK FROM ADVERSE WEATHER EXPOSURE.23. LOADING: DO NOT SUPERIMPOSE LOADS AT ANY POINT UPON EXISTING STRUCTURE BEYOND DESIGN CAPACITY INCLUDING LOADS ATTRIBUTABLE TO MATERIALS, CONSTRUCTION EQUIPMENT, DEMOLITION OPERATIONS AND SHORING AND BRACING.24. VIBRATION: DO NOT USE MEANS, METHODS, TECHNIQUES OR PROCEDURES WHICH WOULD INDUCE VIBRATION INTO ANT ELEMENT OF THE STRUCTURE.25. FIRE: DO NOT USE MEANS, METHODS, TECHNIQUES OR PROCEDURES WHICH WOULD PRODUCE AND HAZARD.26. REMOVE EXISTING NON-LOADING BEARING PARTITION WALLS AS SHOWN ON THEDRAWINGS.27. ELECTRICAL SWITCHES AND WALL OUTLETS ON WALLS TO BE REMOVED, SHALL BEDISCONNECTED AND REMOVED TO NEAREST JUNCTION BOX OR SUPPLY PANEL.28. REMOVE WALL COVERINGS, PANELING, ETC. FROM WALLS INDICATED ON DRAWINGS29. VERIFY PLACEMENT OF REFUSE CONTAINER WITH LOCAL BUILDING AND SAA AIRPORT OFFICIALS.32. REMOVE DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM DEMOLITIONOPERATIONS AND LEGALLY DISPOSE OF OFF THE SITE.33. CLEAN ADJACENT PORTION OF THE STRUCTURE AND IMPROVEMENTS OF DUST,DIRT AND DEBRIS CAUSED BY DEMOLITION OPERATIONS, AS DIRECTED BY THE ARCHITECTOR GOVERNING AUTHORITIES. RETURN ADJACENT AREAS TO CONDITION EXISTINGPRIOR TO THE START OF THE WORK.36. CONTRACTOR TO VERIFY IN FIELD, AND NOTIFY ARCHITECT, IF ANY LOAD BEARINGCONDITIONS EXIST IN PARTITION WALLS TO BE REMOVED.37. G.C. TO COORDINATE ALL NOISY AND OTHERWISE DISRUPTIVE DEMOLITION SHALLBE COMPLETED WHEN THE ADJACENT TENANTS ARE CLOSED.38. G.C. TO INSURE THE CONDITION OF THE FLOOR BY PATCHING AND LEVELING TOOBTAIN A SMOOTH SURFACE. THE FLOOR SURFACE SHALL NOT VARY MORE THAN 1/8"OVER A 10' STRAIGHT EDGE SECTION. G.C. TO FIELD VERIFY ALL BUILDING CONDITIONAND ALL DIMENSIONS HEREIN.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/6/2017 9:17:07 AM1-GD-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE DEMOLITION PLAN - 1ST FLOORPHASE 107-14-2017S12014NNORTH 1/64" = 1'-0"1COMPOSITE DEMOLITION PLAN - 1ST FLOOR PHASE 1ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANF.I.S. CUSTOMSTERMINAL BTERMINAL APHASE 1 DEMOLITION GENERAL NOTES:PHASE 1 DEMOLITION TO INCLUDE, BUT NOT LIMITED TO:1. NEW LOADING DOCK AREA - EXISTING PARKING LOT 2. EXISTING LOADING DOCK AREA3. NEW SCREENING AREA - 1ST AND 2ND FLOORCONTRACTOR TO DEMOLISH / REMOVE ALL EXISTING ITEMS TO PREPARE FOR NEW WORK TO BE COMPLETED. CONTRACTOR TO RETURN ALL EQUIPMENT, MARKED AS SUCK ON PLANS, TO SAA.IF AREA IS NOT CLEARLY DEFINED ON DEMOTION PLANS CONTRACTOR IS TO REFER TO AREAS OF NEW WORK DEFINED ON NEW WORK PLANS, ARCHITECT OF RECORD OR SAA AUTHORITY IN WRITING.CONTRACTOR TO PAY SPECIAL ATTENTION TO PHASING PLANS AND NOTE THAT ALL TEMPORARY WALLS FACING THE PUBLIC AREAS BE PAINTED AND TRIMMED OUT AS TO NOT VISUALLY DISTURB AIRPORT PASSENGERS.CONTRACTOR IS RESPONSIBLE OF MAINTAINING EXISTING AIRPORT SECURITY BARRIERS. CONTRACTOR WILL BADGE ALL OF ITS EMPLOYEES (AT CONTRACTORS EXPENSE) AND FOLLOW ALL SAA AND TSA REGULATIONS.GENERAL NOTE:ALL DUMPSTERS FOR DEMOLITION MUST BE COVERED WHEN NOT BEING USED AND AT THE END OF THE DAY TO PREVENT DEBRIS FROM BLOWING AND CAUSING F.O.D.REVISIONS# DATEDESCRIPTIONBY79CONFORMED SET
Table
Table
Table
Table
Table
Table
Table
Table TableTable TableTable
Table TableTableTable
TableTable Tableshredder
copier
printerhp 8550
EXISTING PARKING GARAGECANOPY1-SA-A1001EXISTING GATES 6-12ROOF OVER BAGGAGE CLAIM 1 AND 2 TO BE REPLACED PHASE 2EXISTING WELCOME CENTEREXISTING SAA OFFICES -REFER TO FIRE PROTECTION DRAWINGSEXISTING OFFICES TO BE DEMOLISHEDEXISTING SCREENING AREA TO BE RELOCATEDEXISTING TERMINAL "A"EXISTING GATES 1-51-SA-A1011DEMOLITION PLAN LEGENDITEMS TO DEMOLISHITEMS TO REMAIN1. EXTENT OF DEMOLITION SHOWN HEREIN IS PROVIDED TO INDICATE THE GENERAL LOCATION AND NATURE OF REQUIRED DEMOLITION WORK. THESE DRAWINGS HAVE BEEN DEVELOPED FROM RECORD DRAWINGS AND WALK-THROUGH FIELD VERIFICATION AND MAY NOT REFLECT ALL EXISTING FIELD CONDITIONS. THE CONTRACTOR SHALL VERIFY THESE CONDITIONS AND NOTIFY THE ARCHITECT IN WRITING OF ANY INCONSISTENCIES BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS. DEMOLITION SHALL NOT BE LIMITED TO THE LIMITS OF CONSTRUCTION AS SHOWN IN THE DEMOLITION DRAWINGS.THE CONTRACTOR SHALL COORDINATE AND ADJUST THE LIMITS OF CONSTRUCTION AS NECESSARY TO ACCOMPLISH THE FINAL PRODUCT AS SHOWN THROUGHOUT THE CONSTRUCTION DOCUMENTS.2. CLEAN AND REMOVE ALL RESIDUES FROM SLAB IN PREPARATION FOR NEW FLOOR FINISH PER FLOOR FINISH PLAN. PROVIDE LEVELING MATERIAL COMPATIBLE WITH FINISH MATERIAL AND SURFACE GRINDING WHERE NECESSARY TO ATTAIN A SMOOTH AND LEVEL SURFACE FOR THE APPLICATION OF NEW FLOOR FINISH.3. PATCH AND REPAIR ALL EXISTING DAMAGED HOLES, OPENINGS ON ALL EXISTING WALLS. REMOVE ALL EXISTING MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT, DEVICES, HANGER'S AND FASTENERS, WHICH ARE DETERMINED TO BE ABANDONED. PATCH AND REPAIR ALL HOLES AND DAMAGE CREATED BY REMOVAL WITH SIMILAR ADJACENT MATERIALS.4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR REPLACEMENT OF ANY FIRE ASSEMBLIES DAMAGED DURING DEMOLITION OR CONSTRUCTION TO MEET ORIGINAL FIRE PROTECTION REQUIREMENTS.DEMOLITION GENERAL NOTES:5. DEMOLITION SHALL BE EXECUTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES.6. REFER TO MECHANICAL, ELECTRICAL. DRAWINGS FOR RELOCATION OF UTILITIES. USE CARE IN DEMO ABOVE CEILING, ALL COMMUNICATIONS CONDUIT AND SPARE CONDUIT TO REMAIN.7. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN ORNOT, AND PROTECT THEM FROM DAMAGE. CONTRACTOR SHALL BEAR ALL EXPENSE OFREPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BYOPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK.8. DEMOLITION/RESTORATION ITEMS MAY NOT BE ALL INCLUSIVE. CONTRACTOR SHALL REVIEW THE REQUIREMENTS OF NEW CONSTRUCTION AND COMPLETE ALL DEMOLITION/ RESTORATION, CUTTING AND PATCHING NECESSARY TO ACHIEVE INTENDED NEW CONDITION AND QUALITY.9. RELOCATION OF ANY ITEMS INVOLVED IN THE WORK IS SUBJECT TO THE CONTRACTOR'S ABILITY TO DO SO WITHOUT PERMANENTLY DAMAGING OR MARRING THE ITEMS TO BE RELOCATED. IF CONTRACTOR IS UNABLE TO RELOCATE ANY ITEM AS PRESCRIBED HEREIN, HE SHALL SUBSTITUTE NEW MATERIAL TO MATCH EXISTING. CONTRACTOR SHALL SAFELY STORE MATERIAL TO BE REUSED UNTIL TIME OF INSTALLATION.10. CONTRACTOR SHALL REMOVE ALL EXISTING FLOOR FINISHES WHERE NOTED ANDPREPARE SLAB TO RECEIVE NEW FLOOR FINISHES UNLESS NOTED OTHERWISE.11. CONTRACTOR SHALL PATCH AND REPAIR ALL WALL SURFACES TO REMAIN THAT ARE DAMAGED BY OPERATIONS IN CONJUNCTION WITH EXECUTION OF THE WORK AND RETURNED TO THEIR ORIGINAL CONDITION.12. DURING DEMOLITION, THE CONTRACTOR SHALL BRACE ALL EXISTINGSTRUCTURES TO MAINTAIN STRUCTURAL INTEGRITY. DO NOT CUT, MODIFY ORDAMAGE STRUCTURAL MEMBERS.13. SELECTIVE DEMOLITION MAY NOT BE INDICATED IN ALL AREAS WHERE IT MAY BENECESSARY TO DEMOLISH ALL OR PART OF AN EXISTING BUILDING COMPONENT TOGAIN ACCESS TO AREAS FOR TIE-IN TO BUILDING SYSTEMS, OR WHICH MAY BEREQUIRED TO INSTALL PROPOSED CONSTRUCTION INDICATED ON THE DRAWINGS.DEMOLITION FOR THESE PURPOSES SHALL BE DONE AT NO ADDITIONAL COST TO THEOWNER AND THE AREAS SHALL BE RETURNED TO THEIR ORIGINAL CONDITION ORPROPOSED CONDITION.14. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN THIS DEMOLITION ANDSHALL REPAIR AT HIS COST ANY ADJACENT CONDITIONS WHICH ARE DAMAGED AS ARESULT OF THIS DEMOLITION.15. PROTECTION: PERFORM DEMOLITION WITH THE LEAST IMPACT ON EXISTINGFACILITIES STILL IN USE, PROVIDE SUPPORT TO ALL STRUCTURAL MEMBERS. ERECTDUST BARRIERS TO ELIMINATE THE SPREAD OF DUST, FUMES OR SMOKE TOOCCUPIED AREAS.16. PROTECT ALL EXISTING FLOOR FINISHES (TILE, CARPET, ETC.) ADJACENT TODEMOLITION AREAS.17. AS A PART OF THIS PROJECT PROVIDE FOR PATCHING AND INFILL OF ALL EXISTINGNON-COMPLIANT OPENINGS AND PENETRATIONS IN RATED WALLS AND FLOORSEPARATIONS WITHIN THE LIMITS OF THE PROJECT AREA AND EXTENDING 5 FEETBEYOND THE PROJECT AREA IN ALL DIRECTIONS. PATCHING AND INFILL SHALL MATCHEXISTING RATED CONSTRUCTION AND MEET CODE REQUIREMENT FOR SEALING OFPENETRATIONS. 18. CONTRACTOR SHALL OBTAIN A COPY OF THE CURRENT UNDERWRITERS LABORATORIES, INC. FIRE RESISTANCE DIRECTORY, VOLUME 1 AND 2 AS A PART OF THIS PROJECT AND SHALL REFER THERETO FOR FULL REQUIREMENTS OF FIRE RATED CONSTRUCTION AND PENETRATIONS.19. DURING DEMOLITION AND CONSTRUCTION, PROTECT ALL ADJACENT AREAS FROM DAMAGE.20. ALL ITEMS INDICATED TO BE SAVED/STORED SHALL BE STORED OFF SITE AT CONTRACTORS OWN EXPENSE. THE CONTRACTOR SHALL BEAR ALL COSTS ASSOCIATED WITH THE REMOVAL, STORAGE, PROTECTION AND REPLACEMENT OF ALL SAID ITEMS FOR THE REINSTALLATION PER THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL ALSO BEAR ALL COSTS ASSOCIATED WITH THE REPLACEMENT OF ALL SAID ITEMS DAMAGED DURING DEMOLITION.21. CUT WORK BY METHODS LEAST LIKELY TO DAMAGE WORK TO BE RETAINED AND WORK ADJOINING. IN GENERAL, WHERE PHYSICAL CUTTING ACTION IS REQUIRED, CUT WORK WITH SAWING AND GRINDING TOOLS, NOT WITH HAMMERING AND CHOPPING TOOLS. CORE DRILL OPENINGS THROUGH CONCRETE WORK.22. PROTECTION: PROVIDE ADEQUATE PROTECTION OF OTHER WORK DURING SELECTIVE DEMOLITION TO PREVENT DAMAGE, AND PROVIDE PROTECTION OF THE WORK FROM ADVERSE WEATHER EXPOSURE.23. LOADING: DO NOT SUPERIMPOSE LOADS AT ANY POINT UPON EXISTING STRUCTURE BEYOND DESIGN CAPACITY INCLUDING LOADS ATTRIBUTABLE TO MATERIALS, CONSTRUCTION EQUIPMENT, DEMOLITION OPERATIONS AND SHORING AND BRACING.24. VIBRATION: DO NOT USE MEANS, METHODS, TECHNIQUES OR PROCEDURES WHICH WOULD INDUCE VIBRATION INTO ANT ELEMENT OF THE STRUCTURE.25. FIRE: DO NOT USE MEANS, METHODS, TECHNIQUES OR PROCEDURES WHICH WOULD PRODUCE AND HAZARD.26. REMOVE EXISTING NON-LOADING BEARING PARTITION WALLS AS SHOWN ON THEDRAWINGS.27. ELECTRICAL SWITCHES AND WALL OUTLETS ON WALLS TO BE REMOVED, SHALL BEDISCONNECTED AND REMOVED TO NEAREST JUNCTION BOX OR SUPPLY PANEL.28. REMOVE WALL COVERINGS, PANELING, ETC. FROM WALLS INDICATED ON DRAWINGS29. VERIFY PLACEMENT OF REFUSE CONTAINER WITH LOCAL BUILDING AND SAA AIRPORT OFFICIALS.32. REMOVE DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM DEMOLITIONOPERATIONS AND LEGALLY DISPOSE OF OFF THE SITE.33. CLEAN ADJACENT PORTION OF THE STRUCTURE AND IMPROVEMENTS OF DUST,DIRT AND DEBRIS CAUSED BY DEMOLITION OPERATIONS, AS DIRECTED BY THE ARCHITECTOR GOVERNING AUTHORITIES. RETURN ADJACENT AREAS TO CONDITION EXISTINGPRIOR TO THE START OF THE WORK.36. CONTRACTOR TO VERIFY IN FIELD, AND NOTIFY ARCHITECT, IF ANY LOAD BEARINGCONDITIONS EXIST IN PARTITION WALLS TO BE REMOVED.37. G.C. TO COORDINATE ALL NOISY AND OTHERWISE DISRUPTIVE DEMOLITION SHALLBE COMPLETED WHEN THE ADJACENT TENANTS ARE CLOSED.38. G.C. TO INSURE THE CONDITION OF THE FLOOR BY PATCHING AND LEVELING TOOBTAIN A SMOOTH SURFACE. THE FLOOR SURFACE SHALL NOT VARY MORE THAN 1/8"OVER A 10' STRAIGHT EDGE SECTION. G.C. TO FIELD VERIFY ALL BUILDING CONDITIONAND ALL DIMENSIONS HEREIN.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/6/2017 9:21:02 AM1-GD-A102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE DEMOLITION PLAN - 2ND FLOORPHASE 107-14-2017S12014 1/64" = 1'-0"1COMPOSITE DEMOLITION PLAN - 2ND FLOOR PHASE 1NNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANF.I.S. CUSTOMSTERMINAL BTERMINAL ADEMOLITION GENERAL NOTES:PHASE 1 DEMOLITION TO INCLUDE, BUT NOT LIMITED TO:1. NEW LOADING DOCK AREA - EXISTING PARKING LOT 2. EXISTING LOADING DOCK AREA3. NEW SCREENING AREA - 1ST AND 2ND FLOORCONTRACTOR TO DEMOLISH / REMOVE ALL EXISTING ITEMS TO PREPARE FOR NEW WORK TO BE COMPLETED. CONTRACTOR TO RETURN ALL EQUIPMENT, MARKED AS SUCK ON PLANS, TO SAA.IF AREA IS NOT CLEARLY DEFINED ON DEMOTION PLANS CONTRACTOR IS TO REFER TO AREAS OF NEW WORK DEFINED ON NEW WORK PLANS, ARCHITECT OF RECORD OR SAA AUTHORITY IN WRITING.CONTRACTOR TO PAY SPECIAL ATTENTION TO PHASING PLANS AND NOTE THAT ALL TEMPORARY WALLS FACING THE PUBLIC AREAS BE PAINTED AND TRIMMED OUT AS TO NOT VISUALLY DISTURB AIRPORT PASSENGERS.CONTRACTOR IS RESPONSIBLE OF MAINTAINING EXISTING AIRPORT SECURITY BARRIERS. CONTRACTOR WILL BADGE ALL OF ITS EMPLOYEES (AT CONTRACTORS EXPENSE) AND FOLLOW ALL SAA AND TSA REGULATIONS.GENERAL NOTE:ALL DUMPSTERS FOR DEMOLITION MUST BE COVERED WHEN NOT BEING USED AND AT THE END OF THE DAY TO PREVENT DEBRIS FROM BLOWING AND CAUSING F.O.D.REVISIONS# DATEDESCRIPTIONBY80CONFORMED SET
UNKRESTRICTEDAREA
KEEP OUTGENERATOR5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
5'- 0 1/4"
BOS
BOS
BOSBOSBOSBOS
REF.DWBUILDING ADDITIONCANOPYCANOPYCANOPYEXISTINGPARKING GARAGENEW LOADING DOCK FACILITYSKYWALK ADDITION 1-LD-A1011EXISTING WELCOME CENTER1-ELD-A1011EXISTING LOADING DOCK1-BC3-A1011INBOUND BAGGAGE CLAIMA1-061-NEE-A10111-NEE-A10111-FIS-A10111-GE-A7015CUSTOMS FISINBOUND BAGGAGENEW GATES 1-4TICKETINGOUTBOUND BAGGAGESCREENINGCUSTOMSFISBLOCKHOUSE ADDITION500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/64" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:44:33 PM1-G-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE FLOOR PLAN - 1ST FLOOR PHASE 107-14-2017S12014NNORTH 1/64" = 1'-0"1COMPOSITE FLOOR PLAN - 1ST FLOOR PHASE 1ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET81
29'-8"29'-1"28'-5"2'5'-10"12'-4"11'-2"12'-4"11'-10"12'-4"12'-5"12'-4"5'-3"10'1'-6"10'-10"3'-8"2'-7"2'4'-1"4'-8"5'-7"4'3'-5"8'-8"8'-1"7'-6"1'-6"1'-6"6"12'-9"5'3'1'-6"6'10'-3"9'-7"TDC #8TDC #7TDC #6TDC #5TDC #4TDC #3TDC #2TDC #1BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVEST TABLE 60" DIVEST TABLE
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVEST TABLE60" DIVEST TABLERoof
Minimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or aboveFRONT
L3ENT
E
REXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVEST TABLE 60" DIVEST TABLE
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVEST TABLE60" DIVEST TABLERoof
Minimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or aboveFRONT
L3 ENT
E
REXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVEST TABLE60" DIVEST TABLEBINSEMPTY
BINSEMPTY
BINSEMPTYBINSEMPTY AT26040 aTiX60" DIVEST TABLE 60" DIVEST TABLE
Roof
Minimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or aboveFRONT
L3ENT
E
R
EXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTY
BINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE 60" DIVEST TABLE
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX
60" DIVEST TABLE60" DIVEST TABLERoof
Minimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONT
L3
ENT
E
R
EXIT TDC/CAT
TDC/CAT
TDC/CAT
TDC/CAT
TDC/CA
TTDC/CAT
TDC/CAT
TDC/CATAVSAVS
FR
O
N
T
ETDBLS
AVSAVS
FR
O
N
T
ETDBLS
FR
O
N
T
ETDBLSAVS
FR
O
N
T
ETDBLS
AVS
AVS
AVS
FR
O
N
TETDBLS
23'-9"3'LADA GA TE WTMDCEIA
1
2ETDETD
ETD
ETD
LL4
3L4
3L3L3
2
3'-9"3'LADA GA TE WTMDCEIA
1
2
3'-9"3'LADA GA TE WTM
DCEIA
1
2
3'-9"3'LADA GA TE WTM
DCEIA
1
EXISTINGPARKING GARAGEBUILDING ADDITIONOPENNEW LOADING DOCK FACILITYSKYWALK ADDITIONNEW SCREENING AREANEW CANOPYTICKETINGNEW ROOFNEW KIDS AREAEXISTINGWELCOME CENTER1-LD-A10312-OB-A10711-NEE-A10121-SA-A10411-SA-A6035NEW GATES 1-4SECURITY BACK CHECK LANENEW CANOPYEXISTING WAITING AREASAA OFFICESEXISTING GATES RENAMED 5-9NEW CANOPYEXISTING WAITING AREAEXISTING GATES RENAMED 10-16SECURITY BACK CHECK LANENEW CANOPYNEW CANOPYNEW CANOPYNEW CANOPY500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/64" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:45:10 PM1-G-A102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE FLOOR PLAN - 2ND FLOOR PHASE 107-14-2017S12014 1/64" = 1'-0"1COMPOSITE FLOOR PLAN - 2ND FLOOR PHASE 1NNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET82
REF.DWFIREEXTINGUISHERBRACKETMOUNTED2'-3"4'-0"2'-3"4'-0"FIREEXTINGUISHERCABINETLOADING DOCKLD-1CHIEFLD-20RESTROOMLD-2COOLERLD-3HVACLD-4STORAGELD-9OFFICELD-6RESTROOMLD-7BADGINGLD-5HVACLD-11INTERVIEWLD-10STORAGELD-17ARMSLD-15CORRIDORLD-14RECEPTIONLD-8OFFICELD-18OFFICELD-19BREAK ROOMLD-21RESTROOMLD-13SHOWERLD-12PATH LD1PATH LD1PATH LD2PATH LD2PATH LD3PATH LD3PATH LD5PATH LD4PATH LD5PATH LD6PATH LD6PATH LD7PATH LD7PATH LD4FE-BFE-BFE-BFE-RFE-RFE-RPOLICE STATIONBADGINGLOADING DOCKITLD-16FIRE RISER ROOMLD-22(2) HOUR WALL UL U914 - FLOOR TO DECK(2) HOUR WALL UL U914- FLOOR TO DECKPATH LD3FE-BFLOOR PALLETS FOR EGRESS DISTANCE REFER TO CHART BELOW - TYPTOTAL EXIT WIDTH REQUIRED (1005.1) TOTAL OCCUPANT LOAD x 0.2 INCHES PER PERSON = INCHES REQUIRED33 PEOPLE x 0.2 INCHES PER PERSON = 6.6 INCHES REQUIREDEXIT WIDTH PROVIDED5 EXIT DOORS:180 INCHES CLEAR WIDTH TOTAL PROVIDED180 INCHES CLEAR WIDTH PROVIDED OCCUPANCY CALCULATIONS - TERMINAL ASPACE / USE OCCUPANCY AREA OCC. PER S.F. OCC. LOAD POLICE STATION B 1720 S.F. 1/100 18BADGING B 925 S.F. 1/100 10LOADING DOCK S 1492 S.F. 1/300 5 TOTAL 4137 S.F. TOTAL OCCUPANTS 33PEOPLEFIRE PROTECTION SERVICES (FBC 906.3(1)FIRE ALARM SYSTEM AND PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AT A MAXIMUM TRAVEL DISTANCE OF 75'. MAXIMUM FLOOR AREA FOR EACH EXTINGUISHER IS 11,250 S.F. MEANS OF EGRESS (FBC 1004.1.2)MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANTBUSINESS100 SF PER OCCUPANTSTORAGE / STOCK300 SF GROSS PER OCCUPANTCOMMON PATH OF EGRESS TRAVEL (1014.3)BUSINESS (SPRINKLED)100 FEET MAXIMUM EXIT ACCESS TRAVEL DISTANCE (1016.2)BUSINESS (SPRINKLED)300 FEET RE: SHEET GS109 SHEET FOR ADDITIONAL INFORMATIONCODE INFORMATION -LOADING DOCK MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT (1004.1.2)LEGENDBUSINESS100 GROSSSTORAGE 300 GROSSEMERGENCY LIGHTINGFEWALL MOUNTED FIRE EXTINGUISHER / 10LB TYPE ABCLIFE SAFETY LEGENDEGRESS LEGENDABCOCCUPANT LOAD AT THIS EXITREQUIRED EXIT WIDTHPROVIDED EXIT WIDTHEMERGENCY LIGHT (EM)EXIT SIGNSFLOOR FINISH0'-0"FE-BFE-R(SEMI-RECESSED CABINET)500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 1:57:35 PM1-LD-A100PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDALIFE SAFETY PLAN - NEW LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1LIFE SAFETY PLAN - NEW LOADING DOCKNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDEGRESS DATA LOADING DOCKEXIT ROUTEDISTANCEPATH LD135' - 4"PATH LD234' - 4"PATH LD349' - 10"PATH LD464' - 7"PATH LD527' - 7"PATH LD647' - 4"PATH LD758' - 7"REVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET83
REF.DW110' - 0"POLICE STATIONFLOOR0'-0"TRUCK WELL-4'-0"LOADING DOCKLD-1RESTROOMLD-2COOLERLD-3HVACLD-4OFFICELD-6RESTROOMLD-7BADGINGLD-5HVACLD-11SHOWERLD-12RESTROOMLD-13CORRIDORLD-14BREAK ROOMLD-21CHIEFLD-20OFFICELD-19OFFICELD-18RECEPTIONLD-8INTERVIEWLD-10STORAGELD-17ARMSLD-15STORAGELD-9ITLD-16LOW WALL - 24" ABOVE GRADECANOPYCANOPYSECURITY FENCINGFLOOR0'-0"FLOOR0'-0"1-LD-A20111-LD-A201211-LD-A30121-LD-A301CANOPY40' - 0"24' - 8"45' - 4"18' - 5"14' - 5"LOW WALL @ 54" A.F.F. - PROVIDE POST SUPPORT AT 48" O.C. EMBED 4" 30" X 30" COMPUTER STATIONS(BY OWNER)21-LD-A30231-LD-A3021-LD-A40111-LD-A40121-LD-A401313' - 8 1/2"8' - 0"2"8' - 5"2"8' - 2 1/2"VERIFY12' - 0"1/4"34' - 8"3' - 4"2' - 0"8"LOADING DOCK RAMP22' - 8"8"LOW WALL - 24" ABOVE GRADE2' - 8"8' - 0"2' - 8"8' - 0"4' - 0"6' - 0"2' - 0"3' - 4"5' - 4"8' - 0"4' - 0"8' - 0"6' - 8"3' - 4"2' - 8"8' - 0"3' - 4"8' - 0"4' - 0"8' - 0"4' - 0"4' - 0"8' - 0"10' - 8"8' - 0"9' - 4 1/4"4' - 10"12' - 2"5' - 5"8' - 4"14' - 1"11' - 5"11' - 5"8' - 4"9' - 9 1/2"5' - 5"9' - 6"5' - 5"8' - 4"10' - 4"1C14' - 8"3' - 4"36' - 8"6' - 0"CLEAR5' - 0"CLEAR4' - 11 1/2"1A1C63661C13B1A1A13D3D3D233333333B3333331140' - 0"1B11322333331C111B44518' - 0"6' - 0"25' - 4"CANOPYCANOPYCANOPY1-LD-A7111234FIRE RISER ROOMLD-226621-LD-A3036"LEVELER PIT7' - 0"6"6"LEVELER PIT7' - 0"6"REF.BY OWNER784FURNITURE (BY OWNER)HVACREFER TO MECH.1111COOLER PACKAGE - PROVIDE AND INSTALL BY G.C.8' - 9"5' - 1"8' - 6 1/2"4' - 6"FIRE RISER ROOMLD-2240' - 0 1/4"8' - 0"TRENCH DRAIN - REFER TO 5/1-LD-A501SIM51-LD-A501REFER TO CIVIL DRAWINGS FOR ALL BOLLARD LOCATIONSCENTER TRELLIS OVER BOTH DOORSMASONRY SCREEN WALL - PHASE 2FRP TO 60" A.F.F. ON BACKSPLASH OF MOP SINKFRP TO 60" A.F.F. ON BACKSPLASH OF MOP SINK10PHOTO PROCESSING #2 -CENTER ON CEILING CAMERADESK(BY OWNER)18" DEEP OVERHEAD CABINETS WITH CABINETS AND COUTERTOP BELOWSHREDDER(BY OWNER)DESK(BY OWNER)36' - 0"6' - 0"COPY MACHINE(BY OWNER)FINGER PRINT / ID / STATION(BY OWNER)PHOTO PROCESSING #1 - CENTER ON CEILING CAMERA6' - 6"DESK(BY OWNER)SIGHT GLASS IN DOOR12' - 11"5"7' - 9"7"10' - 2"5"6' - 0"5"6' - 11 1/2"11"7' - 6"16' - 3 1/4"9' - 9 1/2"5' - 5"6"9' - 0"5 1/2"13' - 4"5' - 0"3' - 9 1/2"5"13' - 0"3' - 4"11' - 8"3' - 4"17' - 8"FILE CABINETSFILE CABINETSFURNITURE (BY OWNER)LOADING DOCK KEYNOTES#1DOCK LEVELERSNOTE: FOR WALL TYPES REFER TO SHEET 1-A501 AND A502248" X 30" SOUND PANELS - (1) EACH WALL3OVERHEAD DOOR4COUNTERTOPS AT 34" A.F.F.5THROUGH WALL EVIDENCE LOCKER, SUPPLIED BY OWNER INSTALLED BY G.C. 6BRUSHED S.S. RECTANGULAR GROMMET IN PANEL FOR ELECTRICAL CORD ACCESS7LOCKERS, SUPPLIED BY OWNER INSTALLED BY G.C.8EXISTING SAFES, BY OWNER93 SHELVES, PAINTED 3/4" THICK PLYWOOD W/ ROUNDED EXPOSED EDGE STRIP, F.R. WITH ADJUSTABLE WALL BRACKET SUPPORT10REFER TO CIVIL, STRUCTURAL AND ELECTRICAL DRAWINGS FOR PUMP BASIN DESIGN11DOCK BUMPERS & DOCK SEAL SYSTEMWALL TYPE LEGENDNEW STUD WALLEXISTING WALLLOW WALLNEW MASONRY WALL500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 1:58:29 PM1-LD-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFLOOR PLAN - NEW LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1FLOOR PLAN - NEW LOADING DOCKORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTHREVISIONS# DATEDESCRIPTIONBY409-08-2017ADDENDUM 44CONFORMED SET84
FFFJJ1-LD-A201211-LD-A30121-LD-A301EXPOSED CEILING10' - 0"9' - 0"9' - 0"9' - 0"9' - 0"10' - 0"9' - 0"9' - 0"LOADING DOCKLD-1RESTROOMLD-2COOLERLD-3STORAGELD-9HVACLD-4RESTROOMLD-7OFFICELD-6BADGINGLD-5INTERVIEWLD-10HVACLD-11SHOWERLD-12RESTROOMLD-13STORAGELD-17ITLD-16ARMSLD-15CORRIDORLD-14RECEPTIONLD-8OFFICELD-18OFFICELD-19CHIEFLD-20BREAK ROOMLD-2121-LD-A30231-LD-A302BAR JOIST ABOVEALUMINUM TRELLISALUMINUM TRELLISALUMINUM TRELLISMETAL SOFFIT PANELALUMINUM TRELLISMETAL SOFFIT PANEL9' - 0"9' - 0"9' - 0"9' - 0"9' - 0"1-LD-A603421-LD-A303COOLER PACKAGE REFER TO SPEC - SUPPLIED AND INSTALLED BY G.C.FIRE RISER ROOMLD-228' - 0"8' - 0"EXPOSED CEILING9' - 0"9' - 0"EXPOSED CEILINGEXPOSED CEILINGAPAPAPAPAPAPAPAPTRELLIS LIGHTING REFER TO ELECTRICALAPAP9' - 0"REFLECTED CEILING PLAN LEGEND2 X 4 LED LIGHTING FIXTURECEILING SUPPLY DIFFUSER. SEE MECHANICAL DWGS.CEILING RETURN DIFFUSER. SEE MECHANICAL DWGS.EXIT SIGN, ARROW INDICATES EXIT DIRECTION SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATIONINDICATES FINISHED GYP. BOARD CEILING ORSOFFITEMERGENCY LIGHTS RE: ELECTRICAL DRAWINGS2 X 2 LAY-IN ACOUSTICAL TILE IN T-BAR GRID. 1.FIXTURES, CONDUITS, DUCTWORK, PIPING, ETC. SHALL BE INSTALLED AS HIGH AS POSSIBLE.2.ADDITIONAL DIRECTIONAL EXIT SIGNS MAY BE REQUIRED. CONTRACTOR TO VERIFY QUANTITIES AND COORDINATE LOCATIONS IN THE FIELD WITH THE FIRE DEPARTMENT FIRE INSPECTOR.3.EMERGENCY LIGHTING SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE.4.MECHANICAL DIFFUSERS TO MATCH ADJACENT CEILING TILE.5. SEE ELECTRICAL DRAWINGS FOR ALL LIGHT FIXTURES REFLECTED CEILING GENERAL NOTESRECESSED LED CAN LIGHTINGSURFACE MOUNTED EXTERIOR WALL PACKINTERIOR WALL HEIGHT LEGENDFULL HEIGHT WALL ATTACHED TO DECKWALL TO EXTEND TO 6" ABOVE FINISHED CEILING - BRACE TO STRUCTURE ABOVE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 1:59:14 PM1-LD-A102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREFLECTED CEILING PLAN - NEW LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1REFLECTED CEILING PLAN - NEW LOADING DOCKORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTHNOTE: ALUMINUM INFILL PANEL (AP). SLOPE TO FRONT EDGE 1/4" / FT. (TYP)REVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET85
SLOPE 1/2:12NEW STANDING SEAM METAL ROOFING (ULTRA DEK BY MBCI OR ARCHITECT APPROVED EQUAL) CONTINUOUS PRE-FINISHED .032 ALUMINUM GUTTER16' - 0"27' - 11"16' - 0"26' - 8"8' - 0"8' - 0"12' - 4"15' - 3 1/2"11' - 6"62' - 10 1/2"5' - 0"DOWNSPOUT4 LOCATIONSNEW STANDING SEAM METAL ROOFING (TITE LOC BY PAC CLAD OR APPROVED EQUAL) ALUMINUM CANOPYNEW STANDING SEAM METAL ROOFING (TITE LOC BY PAC CLAD OR APPROVED EQUAL) SLOPE 3:12SLOPE 3:12WALL LIGHTING FIXTUREREFER TO ELECTRICAL40' - 0"3' - 1"110' - 0"3' - 0"5' - 0"24' - 0"VTRREFER TO PLUMBING21-LD-A50111-LD-A50141-LD-A501DSDSDSDSAPAPAPAPAPAPAPAPFURTURE SECURITY WALL IN PHASE 23' - 0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:01:03 PM1-LD-A103PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAROOF PLAN - NEW LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1ROOF PLAN - NEW LOADING DOCKNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDNOTE: ALUMINUM INFILL PANEL (AP). SLOPE TO FRONT EDGE 1/4" / FT. (TYP)REVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET86
STUCCO FINISHALUMINUM TRELLISW/ TIE-BACKSLOADING DOCK LEVELERS, BUMPERS AND SEALS21-LD-A30231-LD-A302ALUMINUM TRELLISW/ TIE-BACKSSTANDING SEAM CANOPY ROOF BY "PAC CLAD MODEL TITE LOC" WITH 18" SEAM SPACINGWATER PROOF CONCRETE LOADING DOCK RETAINING WALL -SEE STRUCTURALSTUCCO FINISHT/ 10" CMU15'-4"B/ CANOPY12'-0"FLOOR LINE0'-0"PIT DEPTH-4'-0"2' - 8"1' - 4"8' - 0"8' - 0"8' - 0"8' - 0"SECURITY FENCECONTROL JOINT1 1/2" ALUMINUM PIPE RAILSTUCCO FINISHCONTROL JOINTCONTROL JOINTEXTERIOR ELECTRICAL FIXTUREREFER TO ELECTRICALLD1CLD1ALD1LD1BLD821-LD-A303LOADING DOCK LEVELERS, BUMPERS AND SEALSVEHICLE RESTRAINT SYSTEMWINDOW SILL REFER TO 3/1-LD-A6031" STUCCO REVEALB/ TRELLIS8'-0"12INSTALL 5" LETTER SIGNAGE FOR ALL LOADING DOCK DOORS TO IDENTIFY LOADING AND UNLOADING FOR VENDERS - G.C. TO COORDINATE WITH SAA FOR NUMBERING SYSTEM31' - 6"BOLLARDS - REFER TO CIVIL8' - 0"CONTROL JOINT - TYPALUMINUM TRELLISW/ TIE-BACKSBEYOND 5/8" THICK SMOOTH FINISH STUCCO - PAINTED11-LD-A302ALUMINUM TRELLISW/ TIE-BACKS1 1/2"Ø ALUMINUM GUIDERAIL AT LOADING DOCKWALL MOUNTED HVAC UNITREFER TO MECHANICALELECTRICAL DISCONNECT SWITCH; REFER TO ELECTRICALT/ 10" CMU15'-4"BOTTOM OF TRELLIS8'-0"FLOOR LINE0'-0"T/ 10" CMU15'-4"TOP OF RAILING3'-6"FLOOR LINE0'-0"T/ 8" CMU12'-0"PIT DEPTH-4'-0"CONTROL JOINTCLEARANCE4"(MAX.)4' - 0"1' - 6"WATER PROOF CONCRETE REFER TO STRUCTURAL DRAWINGS AND SPECIFICATIONSEXTERIOR ELECTRICAL FIXTUREREFER TO ELECTRICALLD1EMETAL ENCLOSUREREFER TO DETAIL 3/A-LD-A501 ALUMINUM TRELLISW/ TIE-BACKSBEYOND STANDING SEAM CANOPY ROOFMETAL ENCLOSUREREFER TO DETAIL 3/A-LD-A501 STANDING SEAM CANOPY ROOF BY "PAC CLAD MODEL TITE LOC"BOLLARDS -REFER TO CIVILBOTTOM OF CANOPY10'-0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:01:46 PM1-LD-A201PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAEXTERIOR ELEVATIONS - NEW LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1SOUTH ELEVATION - NEW LOADING DOCK 1/4" = 1'-0"2WEST ELEVATION - NEW LOADING DOCKORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET87
11-LD-A301CONTINUOUS PREFINISHED ALUMINUM GUTTER AND DOWNSPOUTS - TIE INTO UNDERGROUND COLLECTION SYSTEM -REFER TO CIVIL DRAWINGSNEW ALUMINUM TRELLIS W/TIE-BACKS7/8" THICK SMOOTH FINISH STUCCO -PAINTEDSTANDING SEAM METAL ROOFING (ULTRA DEK BY MBCI OR APPROVED EQUAL) OVER PEEL AND STICK FLASHING ON 5/8" EXTERIOR SHEATHING AND R-20 POLYISO RIGID INSULATION STUCCO ACCENT BAND -SMOOTH FINISH 8' - 0"FLOOR LINE0'-0"BOTTOM OF TRELLIS8'-0"T/ 8" CMU12'-0"PARAPET15'-4"3' - 9 1/2"1' - 4"4' - 8"6' - 0"31-LD-A501CONTINUOUS PREFINISHED ALUMINUM GUTTER AND DOWNSPOUTS - TIE INTO UNDERGROUND COLLECTION SYSTEM -REFER TO CIVIL DRAWINGSCONTROL JOINTCONTROL JOINTCONTINUOUS PREFINISHED ALUMINUM GUTTER AND DOWNSPOUTS - TIE INTO UNDERGROUND COLLECTION SYSTEM -REFER TO CIVIL DRAWINGSELECTRICAL SERVICE PANELREFER TO ELECTRICALEXTERIOR ELECTRICAL FIXTUREREFER TO ELECTRICALELECTRICAL DISCONNECTREFER TO ELECTRICAL LD14LD1DMECHANICAL EQUIPMENT - REFER TO MECHANICAL41-LD-A501LD22WINDOW SILL REFER TO 3/1-LD-A603T/ 8" CMU (NORTH WALL)13'-4"LD16CONTINUOUS FLASHINGSTANDING SEAM CANOPY ROOF BY "PAC CLAD MODEL TITE LOC"LINTEL REFER TO STRUCTURAL1' - 6"10' - 0"3' - 2"38"X18" WALL LOUVER5' - 5"21-LD-A301STUCCO FINISHNEW ALUMINUM TRELLISW/ TIE-BACKSADJACENT SCREEN WALLREFER TO LANDSCAPING PLANS FOR DETAILSSECURITY WALL TO BE BUILT IN PHASE 2NEW ALUMINUM GUARD RAILAT LOADING DOCKOUTBOUND EXPANSION (FUTURE PHASE OF WORK)FLOOR LINE0'-0"TOP OF SCREEN WALL8'-0"T/ 10" CMU15'-4"T/ 8" CMU12'-0"CLEARANCE4"CONTROL JOINTCONTROL JOINTCONTROL JOINT6' - 0"1' - 4"2' - 8"EXTERIOR ELECTRICAL FIXTUREREFER TO ELECTRICAL1" STUCCO REVEALSIGNAGEROOF LINESTANDING SEAM CANOPY ROOF BY "PAC CLAD MODEL TITE LOC"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:49:21 PM1-LD-A202PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAEXTERIOR ELEVATIONS - NEW LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1NORTH ELEVATION - NEW LOADING DOCK 1/4" = 1'-0"2EAST ELEVATION - NEW LOADING DOCKORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET88
21-LD-A301BADGINGLD-51-LD-A30311-LD-A5014CONTINUOUS 5"X6" PREFINISHED ALUMINUM GUTTERSTANDING SEAM METAL ROOF BY PAC CLAD MODEL TITE LOC -CANOPY ROOFFLOOR LINE0'-0"JOIST BEARING12'-8"CANOPY9'-10"T / 10" CMU15' - 4"T / 8" CMU12' - 0"T / STOREFRONT8' - 0"T / RAILING3' - 6"10' - 0"4' - 6"HALF WALLCONTINUOUS PRE-FINISHED ALUMINUM COPING"ULTRA DEK BY MBCI" STANDING SEAM ROOF OVER PEEL AND STICK MEMBRANE OVER 5/8" EXTERIOR SHEATHING OVER RIGID INSULATION - R-20 MIN OVER METAL DECKCONTINUOUS FLASHINGDOCK SEAL -BEYONDMETAL RAILING -PAINTEDSTANDING SEAM METAL ROOF BY PAC CLAD MODEL TITE LOC - CANOPY ROOFJOIST BEARING14' - 0"LD71-LD-A711511-LD-A301LOADING DOCKLD-1BADGINGLD-5INTERVIEWLD-10ARMSLD-15CORRIDORLD-14BREAK ROOMLD-211-LD-A3021COOLERSUSPENDED GYPSUM BOARD CEILINGW/ METAL FRAMING SYSTEMSOUND WALL PANELS9' - 0"ACOUSTICAL CEILING W/ GRID SYSTEMACOUSTICAL CEILING W/ GRID SYSTEMBREAK LINE IN SECTION MARKERLD1ELD1DLD17LD15LD14"ULTRA DEK BY MBCI" STANDING SEAM ROOF OVER PEEL AND STICK MEMBRANE OVER 5/8" EXTERIOR SHEATHING OVER RIGID INSULATION - R-20 MIN OVER METAL DECK8' - 0"15' - 4"10' - 0"FLOOR LINE0'-0"T/ 10" CMU15'-4T/ 8" CMU12'-0"BRACE ALL WALLS THAT DO NOT EXTEND TO THE DECK500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:02:33 PM1-LD-A301PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDABUILDING SECTIONS - NEW LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1NORTH - SOUTH SECTION AT LOADING DOCK 1/4" = 1'-0"2EAST - WEST SECTION AT LOADING DOCKORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 444CONFORMED SET89
ULTRA DEK METAL ROOF BY MBCIOVER CONTINUOUS PEEL AND STICK MEMBRANE OVER EXTERIOR GRADE SHEATHING ON R-20 RIGID INSULATION ON METAL DECK1' - 4"HOLLOW METAL DOOR ANDFRAME; REFER TO DOOR SCHEDULECORE FILL 500 ON ALL EXTERIOR WALLS - TYPALUMINUM TRELLIS W/TIE-BACK RODS AND DIVERTER PANSTEEL JOISTS; REFER TOSTRUCTURAL5/8" STUCCO FINISHOVER CMU6" CONCRETE SLAB; REFERTO STRUCTURAL10 MIL VAPOR BARRIER ONTERMITE TREATED COMPACTED FILLNEW CONCRETE FOOTER;REFER TO STRUCTURALNEW CONCRETE SIDEWALK;REFER TO CIVIL.032 ALUMINUM COPING CAPOVER P.T. WOOD BLOCKING3' - 0"FLOOR FINISH AS SCHEDULED1-LD-A5011LOADING DOCKLD-1T/ 10" CMU15'-4"FLOOR LINE0'-0"T/ DOOR FRAME7'-4"T/ 8" CMU12'-0"EXTEND ROOF FLASHING OVER PARAPET - TYPRAIN DIVERTER.032 ALUMINUM COPING CAPOVER P.T. WOOD BLOCKINGULTRA DEK METAL ROOF BY MBCIOVER EXTERIOR SHEATHING ON R-20RIGID INSULATION ON METAL DECK2'x2' ACT AND GRID5/8" STUCCO FINISHOVER 10" CMU WALL5/8" GYP. BRD. OVER 1 1/2" FURRING STRIPS @ 16" O.C.W/ RIGID INSULATIONCLEAR ANODIZED ALUMINUM WINDOW FRAMECONTINUOUS ALUMINUM FLASHING WITHCAULK ON INSIDECONTINUOUS ALUMINUM FLASHING WITHCAULK1/2" SOLID SURFACECONT. VINYL BASECONCRETE SLAB;REFER TO STRUCTURAL10 MIL VAPOR BARRIER OVERTERMITE TREATED COMPACTED FILLCONT. CONCRETE FOOTING;REFER TO STRUCTURALSTEEL JOISTS;REFER TO STRUCTURAL1-LD-A5012CONT. SILICONE SEALANTCONT. SILICONE SEALANT5/8" STUCCO FINISHOVER CMU WALLBADGINGLD-5FLOOR LINE0'-0"T/ WINDOW8'-0"T/ 8" CMU12'-0"T/ 10" CMU15'-4"GRADE REFER TO CIVILSILL5'-4"CORE FILL 500 ON ALL EXTERIOR WALLS - TYPCORE FILL 500 ON ALL EXTERIOR WALLS - TYPCONT. FOOTING;REFER TO STRUCTURALCONCRETE SLAB;REFER TO STRUCTURAL10 MIL VAPOR BARRIER OVERTERMITE TREATED CLEAN COMPACTED FILL5/8" GYP. BRD. OVER 1 1/2" FURRINGSTRIPS WITH RIGID INSULATIONFLOOR FINISH AS SCHEDULEDOFFICELD-182' - 8"1' - 4"3' - 0"1/2" SOLID SURFACE SILLCLEAR ANODIZED ALUMINUM WINDOW FRAME - KAWNEER IR501T WITH THERMAL GLAZINGCONT. CAULK AT PAN FLASHING5/8" GYP. BRD. OVER 1 1/2" FURRINGSTRIPS WITH RIGID INSULATION2'x2' ACT AND GRIDSTEEL JOISTS;REFER TO STRUCTURALULTRA DEK METAL ROOF BY MBCIOVER EXTERIOR SHEATHING ON R-20RIGID INSULATION ON METAL DECK.032 ALUMINUM COPING CAP OVERP.T. WOOD BLOCKING5/8" STUCCO FINISHOVER CMU WALLALUMINUM TRELLISWITH TIE-BACKS AND RAINDIVERTERCONT. SILICONESEALANTCONT. SILICONESEALANT5/8" STUCCO FINISHOVER CMU WALL1-LD-A5012FLOOR LINE0'-0"T/ WINDOW8'-0"T/ 8" CMU12'-0"T/ 10" CMU15'-4"GRADE REFER TO CIVILSILL5'-4"CORE FILL 500 ON ALL EXTERIOR WALLS - TYPCORE FILL 500 ON ALL EXTERIOR WALLS - TYP500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 3/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:03:28 PM1-LD-A302PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL SECTIONS - NEW LOADING DOCK07-14-2017S12014 3/4" = 1'-0"1LOADING DOCK WALL SECTION @ DOOR 3/4" = 1'-0"2LOADING DOCK WALL SECTION @ WINDOW 3/4" = 1'-0"3LOADING DOCK WALL SECTION @ HIGH WINDOWORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET90
BADGINGLD-5ALUMINUM STOREFRONTDOOR WITH TRANSOM; REFERTO DOOR SCHEDULEALUMINUM TRELLIS W/TIE-BACK RODSALUMINUM LOADING DOCKRAILING BEYONDCONCRETE SLAB;REFER TO STRUCTURAL10 MIL VAPOR BARRIEROVER TERMITE TREATEDCOMPACTED FILLCONT. CONCRETE FOOTER;REFER TO STRUCTURALULTRA DEK METAL ROOF BY MBCIOVER CONTINUOUS PEEL AND STICK MEMBRANE OVER EXTERIOR SHEATHING ON R-20 RIGID INSULATION ON METAL DECK.032 ALUMINUM COPING CAPOVER P.T. WOOD BLOCKING5/8" STUCCO FINISHOVER CMU WALL5/8" GYP. BRD. OVER 1 1/2" FURRING STRIPSW/ RIGID INSULATIONSTANDING SEAM CANOPY ROOFBEYONDSTEEL JOISTS;REFER TO STRUCTURALDOCK SEAL BEYOND2' - 0"1' - 6"2'x2' ACT AND GRIDT/ 8" CMU12'-0"CORE FILL 500 ON ALL EXTERIOR WALLS - TYP1-LD-A5013HEAD DOCK SEALJAMB DOCK SEALBEYONDROLL-UP DOORREFER TO SCHEDULEALUMINUM GUARDRAILREFER TO CIVILRETAINING WALLREFER TO CIVIL / STRUCTURALREFER TO STRUCTURAL FOR ELEVATION, SIZE AND REINFORCEMENTEXPANSION JOINT W/ SEALANT AND BACKER RODWATER PROOF CONCRETEREFER TO STRUCTURALTRENCH DRAINLOADING DOCK APRONSLOPED TO TRENCH DRAINSREFER TO CIVIL & STRUCT.RUBBER DOCK BUMPERREFER TO SPEC.GALVANIZED DOCK LEVELER PLATFORMGALVANIZED DOCK LEVELER PIT FRAMEVERIFY W/ SUPPLIER1' - 7"VERIFY W/ SUPPLIER6' - 0"PIT WALLREFER TOSTRUCT.SLOPEMIN.4"8" CMU REFER TO STRUCTURAL FOR BOND BEAM LOCATION AND REINFORCINGSTEEL ANGLE AT PERIMETER OF PITREFER TO STRUCTURAL NEW 5" CONCRETE SLAB;REFER TO STRUCTURALNEW 10 MIL VAPOR BARRIEROVER TERMITE TREATEDCOMPACTED FILLT/ 10" CMU15'-4"FLOOR LINE0'-0"T/DOOR10'-0"FLOOR LINE-4'-0"B/ CANOPY12'-0"T/ 10" CMU15'-4"48" O.C.CORE FILL 500 ON ALL EXTERIOR WALLS - TYP500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 3/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:50:20 PM1-LD-A303PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL SECTIONS - NEW LOADING DOCK07-14-2017S12014 3/4" = 1'-0"1LOADING DOCK WALL SECTION 2ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BY 3/4" = 1'-0"2LOADING DOCK WALL SECTION 3CONFORMED SET91
RESTROOMLD-21-LD-A71211245e11d8a1312171920HVACLD-4COOLERLD-3LOADING DOCKLD-13' - 6"1' - 0"7 1/4"7' - 3"1' - 3"1' - 4 1/2"1' - 6"7' - 8"234LD23' - 0"6"5' - 6"RESTROOMLD-71245b11d8a131219201-LD-A71256782"8' - 0"1' - 3"5' - 1 1/2"1' - 0"2' - 0"1' - 0"3' - 6"1' - 6"1' - 6"3331A7' - 6"MASONRY OPENING3' - 4"SHOWERLD-12RESTROOMLD-13121345e8a12192011d142019125b8a11e133' - 9"5' - 2 1/2"7' - 5 1/2"6"9' - 3 1/2"7' - 4 1/2"5 1/2"7 1/2"SHOWERREFER TO PLUMBINGLD12LD131-LD-A7121191-LD-A71215131' - 6"1' - 6"CORRIDORLD-14HVACLD-1110121614SURFACE MOUNTED OPTION141516#136" GRAB BAR242" GRAB BAR3BABY CHANGING TABLEa. SOLID SURFACE BABY CHANGING TABLE WITH INTEGRAL 4" FRONT EDGEb. STAINLESS STEEL RECESSED BABY CHANGING STATIONc. SURFACE MOUNTED ADA CHANGING STATION4WALL/ FLOOR MOUNTED TOILET - FLUSH VALVE ON OPEN SIDE OF SPACE IN ALL ADA STALLS - REFER TO PLUMBING5TOILET PAPER DISPENSERa. RECESS MOUNTED JUMBO TISSUE DISPENSERb. RECESS MOUNTED JUMBO TISSUE DISPENSER WITH SANITARY NAPKIN DISPOSALc. NOT USEDd. NOT USEDe. PARTITION/WALL MOUNTED JUMBO DISPENSER7SANITARY NAPKIN DISPOSALa. SHARED PARTITION MOUNTEDb. PARTITION SURFACE MOUNTEDc. RECESSED8MIRRORa. 24" X 36" WALL MOUNTEDb. 24" X 48" WALL MOUNTEDc. 18" X 36" WALL MOUNTED9WALL MOUNTED URINAL10SOLID SURFACE COUNTER WITH 1 1/2" INTEGRAL FRONT EDGE. COUNTER MOUNTED AT 5'-0" AFF.11SINKS - REFER TO PLUMBING & ELECTRICAL DRAWINGSa. ADA SINGLE SOLID SURFACE TROUGH SINK WITH TOUCHLESS HANDWASHING CONTROLb. CONTINUOUS SOLID SURFACE TROUGH SINK AND 2 TOUCHLESS WASH BAR. c. CONTINUOUS SOLID SURFACE TROUGH SINK AND 3 TOUCHLESS WASH BAR. d. STANDARD ADA COMPLIANT WALL MOUNTED SINK WITH ADA FAUCET CONTROLSe. ADA COMPLIANT DROP IN SINK AND FAUCETRESTROOM LEGEND12ADA WALL MOUNTED SOAP DISPENSER13ADA WALL MOUNTED DRYERADA COMPLIANT SHOWER SEAT14SHOWER CURTAIN AND ROD15PLASTIC LAMINATE TALL CABINET1617MOP SINK WITH WALL MOUNTED MOP CLIPS18HI / LOW ADA DRINKING FOUNTAINS19WALL MOUNTED COAT HOOKS20ADA RESTROOM WALL SIGNAGE21WALL TILE - REFER TO SHEET G106 FOR FINISHa. FIELD TILEb. ACCENT TILEc. BULLNOSE TILEd. COVE BASE TILE 1. REFER TO SHEET G111 FOR ADA SPECIFICATIONS.2. ALL FIELD WALL TILE GROUT LINES TO ALIGN WITH FLOOR GROUT LINES. 3. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.GENERAL NOTES22TOILET PARTITION23PARTITION MOUNTED COAT HOOKXX24NAPKIN/TAMPON VENDOR6PLASTIC LAMINATE COUNTER WITH 4" BACKSPLASH ON 3 SIDES. COLOR TBD.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:04:16 PM1-LD-A401PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAENLARGED PLANS - RESTROOMS - NEW LOADINGDOCK07-14-2017S12014 1/2" = 1'-0"1LOADING DOCK RESTROOM 1/2" = 1'-0"2BADGING RESTROOM 1/2" = 1'-0"3POLICE STATION RESTROOMORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY409-08-2017ADDENDUM 44CONFORMED SET92
FULL HEIGHT PARAPET FLASHINGNEW ULTRA DEK METAL ROOF BY MBCI ON EXTERIOR SHEATHINGR-20 RIGID INSULATIONMETAL DECKNEW 0.40 ALUMINUM COPING CAP OVER PRESSURE TREATED WOOD BLOCKINGPREFINISHED ALUMINUM TRIM/ CLIP, OVER 5/8" SHEATHINGPRESSURE TREATED WOOD BLOCKING5/8" STUCCO FINISH OVER CMU10" CMU8" BOND BEAMSTEEL ANGLE - REFER TO STRUCTURAL T/ 8" CMU12'-0"T/ 10" CMU15'-4"CONTINUOUS DRIP EDGECONTINUOUS PEEL AND STICK MEMBRANEBOND BEAM - REFER TO STRUCTURALBOND BEAM - REFER TO STRUCTURALPAINTCORE FILL 500 ON ALL EXTERIOR WALLS - TYP5/8" EXTERIOR SHEATHINGPREFINISHED METAL SOFFIT PANELULTRA DEK STANDING SEAM METAL ROOFINGMETAL FRAMINGPEAL & STICK WEATHER BARRIERPREFINISHED METAL FLASHINGBOND BEAM - REFER TO STRUCTURALBOND BEAM - REFER TO STRUCTURALCORE FILL 500 ON ALL EXTERIOR WALLS - TYPNEW 0.40 ALUMINUM COPING CAP OVER PRESSURE TREATED WOOD BLOCKINGPREFINISHED ALUMINUM TRIM/ CLIP, OVER 1/2" SHEATHINGPRESSURE TREATED WOOD BLOCKING5/8" STUCCO FINISH OVER CMU10" CMU8" CMU - REFER TO STRUCTURALPARAPET METAL FLASHINGNEW ULTRA DEK METAL ROOF BY MBCI ON EXTERIOR SHEATHINGR-20 RIGID INSULATIONMETAL DECKGWB. OVER 1 1/2" FURRING STRIPS W/ RIGID INSULATIONT/ 8" CMU12'-0"T/ 10" CMU15'-4"BOND BEAM - REFER TO STRUCTURALBOND BEAM - REFER TO STRUCTURALCORE FILL 500 ON ALL EXTERIOR WALLS - TYPNEW ULTRA DEK BY MBCI OR ARCHITECT APPROVED EQUAL METAL ROOF BY MBCI ON EXTERIOR SHEATHING3" R-20 RIGID INSULATIONMETAL DECK5/8" STUCCO FINISH OVER CMUGWB. OVER 1 1/2" FURRING STRIPS W/ RIGID INSULATION -PAINTED8" CMU - REFER TO STRUCTURAL FOR BOND BEAM LOCATION AND REINFORCEMENTSTEEL ANGLE - REFER TO STRUCTURAL TOP OF MASONRY13'-4"CONTINUOUS 5"X6" PREFINISHED ALUMINUM GUTTERCONTINUOUS FLASHINGCORE FILL 500 ON ALL EXTERIOR WALLS - TYP12" WIDE METAL TRENCH DRAIN BY ZURN MODEL Z882 PERMA-TRENCH OR ENGINEER APPROVED EQUALSLOPE TO DRAINSLOPE TO DRAIN* SLOPE BOTTOM OF TRENCH DRAINTO TIE IN WITH EXISTING DRAINAGECONCRETE PAVING- REFER TO STRUCTURAL FOR REINFORCEMENT10 MIL. VAPOR BARRIERCOMPACTED EARTH1' - 0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:50:55 PM1-LD-A501PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADETAILS - NEW LOADING DOCK07-14-2017S12014 1 1/2" = 1'-0"1LOADING DOCK PARAPET DETAIL 1" = 1'-0"3LOADING DOCK CANOPY DETAIL 1 1/2" = 1'-0"2LOADING DOCK PARAPET DETAILORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BY 1 1/2" = 1'-0"4LOADING DOCK ROOF DETAIL. 3" = 1'-0"5TRENCH DRAINCONFORMED SET93
REF.DWLD125002501LD1ALD2LD1DLD1ELD1CLD1BLD14LD13LD12LD11LD10LD18LD19LD20LD8LD8ALD17LD15LOADING DOCKLD-1RESTROOMLD-2COOLERLD-3HVACLD-4OFFICELD-6RESTROOMLD-7BADGINGLD-5HVACLD-11SHOWERLD-12RESTROOMLD-13CORRIDORLD-14BREAK ROOMLD-21CHIEFLD-20OFFICELD-19OFFICELD-18RECEPTIONLD-8INTERVIEWLD-10STORAGELD-17ARMSLD-15STORAGELD-9LD22FIRE RISER ROOMLD-22ITLD-16LD16LD7LD9LD4LD6LD5WALL TYPE LEGENDNEW WALLEXISTING WALLDOOR TAG - REFER TO SCHEDULE#NEW MASONRY WALLADD SIGN TO FRONT FACE OF ALL DOORS THAT ENTER INTO SECURE AREAHEIGHT = 18"WIDTH = 18"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:06:58 PM1-LD-A601PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADOOR SCHEDULE AND KEY PLAN - NEW LOADINGDOCK07-14-2017S12014 3/16" = 1'-0"1DOOR SCHEDULE KEY PLAN - NEW LOADING DOCKNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDDOOR SCHEDULE - LOADING DOCKSAA #CARDREADERDoor # Room NameDoor Size DoorLabelDetails FrameHardwareSetCommentsWidth Height Thickness Door Material Door FinishHead Jamb Threshold Material FinishYES LD1 LOADING DOCK 3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT AUTHORIZEDPERSONNEL ONLY1/1-LD-A602 2/1-LD-A602 3/1-LD-A602 HOLLOW METAL PAINT 3NO LD1A LOADING DOCK 6' - 0" 8' - 0" 1 3/4" ALUMINUMPREFINISHED10/1-LD-A602 11/1-LD-A602 12/1-LD-A602 STEELPAINT 1NO LD1B LOADING DOCK 8' - 6" 10' - 0" 1 3/4" ALUMINUMPREFINISHED10/1-LD-A602 11/1-LD-A602 12/1-LD-A602 STEELPAINT 1 PROVIDE DOCK BUMPERS ANDDOCK SEALSNO LD1C LOADING DOCK 8' - 6" 10' - 0" 1 3/4" ALUMINUMPREFINISHED10/1-LD-A602 11/1-LD-A602 12/1-LD-A602 STEELPAINT 1 PROVIDE DOCK BUMPERS ANDDOCK SEALSYES LD1D LOADING DOCK 6' - 0" 8' - 0" 1 3/4" ALUMINUMPREFINISHED10/1-LD-A602 11/1-LD-A602 12/1-LD-A602 STEELPAINT 1YES LD1E LOADING DOCK 3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT1/1-LD-A602 2/1-LD-A602 3/1-LD-A602 HOLLOW METAL PAINT 2NO LD2 RESTROOM 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAINUNISEX -RESTROOM7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 5NO LD4 HVAC3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 6YES LD5 BADGING 3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT BADGING OFFICE 1/1-LD-A602SIM2/1-LD-A602SIMHOLLOW METAL PAINT 14 90 MINUTE FIRE RATED DOOR WITH12 X 24 SIGHT GLASS AND REMOTEDOOR UNLOCK / BUZZERNO LD6 OFFICE 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 7NO LD7 RESTROOM 3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINTUNISEX -RESTROOM1/1-LD-A602SIM2/1-LD-A602SIMHOLLOW METAL PAINT 5 90 MINUTE FIRE RATED DOORN0 LD8 RECEPTION 3' - 0" 7' - 0" 1 3/4" STOREFRONT PREFINISHED POLICE STATION 1/1-LD-A602 2/1-LD-A602 3/1-LD-A602 ALUMINUM PREFINISHED 25 ADA POWDER ACTUATED DOORYES LD8A RECEPTION 3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 1412 X 24 ONE WAY / SITE VISIONGLASSNO LD9 STORAGE 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN7/1-LD-A602 8/1-SA-A602HOLLOW METAL PAINT 10NO LD10 INTERVIEW 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN INTERVIEW 7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 11 LOCKET OPPERATES FROMCORRIDOR ONLYNO LD11 HVAC3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN MECHANICALROOM7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 6NO LD12 RESTROOM 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN UNISEX-SHOWER 7/1-LD-A6028/1-LD-A602HOLLOW METAL PAINT 5NO LD13 RESTROOM 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAINUNISEX -RESTROOM7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 5YES LD14 CORRIDOR 3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT AUTHORIZEDPERSONNEL ONLY1/1-LD-A602 2/1-LD-A601 3/1-LD-A602 HOLLOW METAL PAINT 2 12 X 24 ONE WAY / SITE VISIONGLASSYES LD15 ARMS3' - 0" 7' - 0" 1 3/4" STEELSTEEL ARMS ROOM 7/1-LD-A602 8/1-LD-A602STEELPAINT 15 HI SECURITY DOOR HARDWAREYES LD16 IT3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT AUTHORIZEDPERSONNEL ONLY1/1-LD-A602 2/1-LD-A602 3/1-LD-A602 HOLLOW METAL PAINTNO LD17 STORAGE 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 9NO LD18 OFFICE 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN7/1-LD-A602 8/1-LD-A601HOLLOW METAL PAINT 11NO LD19 OFFICE 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN7/1-LD-A602 8/1-LD-A602HOLLOW METAL PAINT 11NO LD20 CHIEF3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAINCHIEF7/1-LD-A6028/1-LD-A602HOLLOW METAL PAINT 11NO LD22 FIRE RISERROOM3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT AUTHORIZEDPERSONNEL ONLY1/1-LD-A602 2/1-LD-A602 3/1-LD-A602 HOLLOW METAL PAINTGENERAL NOTE: IF DOOR DOES NOT HAVE A CARD READER THEN IT WILL REQUIRE A LOCK AND KEY. KEYING WILL REQUIRE COORDINATION WITH S.A.A.REVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 444CONFORMED SET94
SEALANT, BOTH SIDESHOLLOW METAL DOOR1 1/2" RIGID INSULATION5/8" GYPSUM BOARDLINTEL WITH HORIZONTAL REINFORCEMENT5/8" 3 COAT MEDIUM SAND FINISH STUCCO2X4 WOOD BLOCKING4" HOLLOW METAL FRAME7'-4" A.F.F.5/8" 3 COAT MEDIUM SAND FINISH STUCCOHOLLOW METAL DOORAND 2" FRAMECONCRETE GROUT WITH VERTICAL REINFORCEMENT5/8" GYPSUM BOARD OVER 1 1/2" RIGID INSULATIONSEALANT, BOTH SIDESMASONRY ANCHORDOORHOLLOW METAL DOORFRAMEFLOOR FINISH PER SCHEDULEMETAL THRESHOLD SET IN FULLBET OF MASTIC(2) 3'x7' ALUMINUM STOREFRONT DOORSW/ IMPACT RESISTANT GLASS; GRAY TINT ALUMINUM JAMBBEYONDALUMINUMSTOREFRONTSYSTEMSEALANT - BOTH SIDESP.T. WD SHIM5/8" GYPSUM WALL BOARD1 1/2" RIGID INSULATIONLINTEL - SEE STRUCTURAL2 X 4 WOOD BLOCKINGT.O. TRANSOM2 1/2"5"NEW ALUM. DOOR REFERTO DOOR SCHEDULEGROUTED REINFORCED CELLNEW ALUMINUM JAMB ATTACHEDTO EXISTING STOREFRONT2 1/2"
3/32"3'-0" X 7'-0" DRSEALANT - BOTH SIDES5/8" GYPSUM WALL BOARD1 1/2" RIGID INSULATION2 X 4 WOOD BLOCKING5"EXTERIORPORCELAIN TILE@ LOBBY3/8" PREFORMEDISOLATION JOINTALUM. THRESHOLD RE: TO HARDWARESCHEDULEAPPLIED SWEEPALUM. JAMBBEYOND3'X7' DBL DRS WITH IMPACT GLASS; GRAY TINT10"5/8" GYPSUM BOARD BOTH SIDES3 5/8" METAL STUDS PER WALL TYPESOLID CORE WOOD DOOR BATT INSULATION REFERTO WALL TYPESHOLLOW METAL FRAME7'-0" A.F.F.5/8" GYPSUMBOARD BOTHSIDESDOUBLE 3 5/8"METAL STUDS PER WALL TYPEHOLLOW METALFRAMESOLID CORE WOOD DOOR BATT INSULATION REFERTO WALL TYPES7' - 0"2"MATCH EXISTING HEIGHTCARD READER7' - 2"2"3' - 0"2"3' - 4"SINGLE FLUSH HOLLOW METAL DOOR7' - 0"2"MATCH EXISTING HEIGHTCARD READER7' - 2"2"3' - 0"2"3' - 4"12X24 ONE WAY SITE VISION GLASS2' - 0"6"6"1' - 0"ROLL UP DOOR8" REINFORCED CMU FILLED CELL REFER TO STRUCTURALPAINTHEADPLATE BEYONDEXTERIORLOADING DOCK5/8" THICK (3) COAT SMOOTH FINISH STUCCO OVER REINFORCED 8" CMUFLAME BAFFLEPROTECTIVE STEEL HOOD5/8" THICK (3) COAT SMOOTH FINISH STUCCO OVER REINFORCED 8" CMU8" CMU LINTELS - REFER TO STRUCTURALEXTERIORLOADING DOCK500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:08:01 PM1-LD-A602PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADOOR DETAILS, ELEVATIONS AND HARDWARESETS - NEW LOADING DOCK07-14-2017S12014 3" = 1'-0"1EXTERIOR HM DOOR HEAD 3" = 1'-0"2EXTERIOR H/M DOOR JAMB 3" = 1'-0"3THRESHOLD DETAIL 3" = 1'-0"4ALUMINUM ENTRY DOOR HEAD 3" = 1'-0"5ALUMINUM ENTRY DOOR JAMB 3" = 1'-0"6ALUMINUM DOOR THRESHOLD 3" = 1'-0"7INTERIOR DOOR HEAD 3" = 1'-0"8INTERIOR DOOR JAMB 1/2" = 1'-0"9DOOR ELEVATIONS 3" = 1'-0"11ROLL UP DOOR JAMB 3" = 1'-0"10ROLL UP DOOR HEADREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET95
REF.DWLOADING DOCKLD-1RESTROOMLD-2COOLERLD-3HVACLD-4OFFICELD-6RESTROOMLD-7BADGINGLD-5HVACLD-11SHOWERLD-12RESTROOMLD-13CORRIDORLD-14BREAK ROOMLD-21CHIEFLD-20OFFICELD-19OFFICELD-18RECEPTIONLD-8INTERVIEWLD-10STORAGELD-17ARMSLD-15STORAGELD-9FIRE RISER ROOMLD-221111112ITLD-1612' - 8"8' - 0"4' - 0"4' - 0"WINDOW TYPE 1KAWNEER IR501T OR ARCHITECT APPROVED EQUAL STOREFRONT WITH THERMAL GLASS14' - 8"3' - 0"3' - 0"6' - 0"WINDOW TYPE 2KAWNEER IR501T OR ARCHITECT APPROVED EQUAL STOREFRONT WITH THERMAL GLASS2HOLLOW METAL FRAME BY KAWNEER IR501T OR ARCHITECT APPROVED EQUALSEALANT - BOTH SIDES3/8" SHIM5/8" GYPSUM WALL BOARD -PAINTEDCORNER J-BEAD1 1/2" RIGID INSULATIONLINTEL - SEE STRUCTURALHORIZONTAL REINFORCEMENT5/8" THICK 3 COAT SMOOTH FINISH STUCCO - PAINTEDWINDOW GLAZING2 X 4 WOOD BLOCKINGHOLLOW METAL FRAME OR SIMILARSEALANT - BOTH SIDES3/8" SHIM5/8" GYPSUM WALL BOARDCORNER J-BEAD1 1/2" RIGID INSULATIONCMU FILLED CELLVERTICAL REINFORCEMENT5/8" THICK 3 COAT MEDIUM SAND FINISH STUCCO - PAINTEDWINDOW GLAZING2X4 WOOD BLOCKINGMETAL FRAMESILL TOP TRIM PIECE1 1/2" RIGID INSULATION5/8" GYPSUM WALL BOARD -PAINTED5/8" THICK 3 COAT MEDIUM SAND FINISH STUCCO -PAINTEDGROUT FILLED CMUHORIZONTAL REINFORCEMENTMETAL SUB STILL500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 10:56:17 AM1-LD-A603PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWINDOW SCHEDULE AND KEY PLAN - NEWLOADING DOCK07-14-2017S12014ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUND 1/8" = 1'-0"6WINDOW SCHEDULE KEY PLAN - NEW LOADING DOCK 3/4" = 1'-0"4WINDOW ELEVATIONS 3" = 1'-0"1WINDOW HEAD DETAIL 3" = 1'-0"2WINDOW JAMB DETAIL 3" = 1'-0"3WINDOW SILL DETAILREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET96
REF.DWLOADING DOCKLD-1COOLERLD-3RESTROOMLD-2HVACLD-4STORAGELD-9RESTROOMLD-7BADGINGLD-5INTERVIEWLD-10OFFICELD-18RECEPTIONLD-8OFFICELD-19CHIEFLD-20BREAK ROOMLD-21CORRIDORLD-14ARMSLD-15STORAGELD-17RESTROOMLD-13SHOWERLD-12HVACLD-11OFFICELD-61-LD-A71211-LD-A71251-LD-A7121191-LD-A7121513234678101216142G116LOCKERS1-LD-A71112345G1163G1163G116COORDINATE FLOOR TRANSITION WITH DOOR THRESHOLDEQUIPMENT BY OWNER1-LD-A603421-LD-A303FIRE RISER ROOMLD-22ITLD-161-LD-A7115FINISH LEGENDCARPETCARPET ACCENTCARPET ACCENTVCTTILE FLOORINGTERRAZZO TILETERRAZZO TILE ACCENTTERRAZZO TILE ACCENTCHILDREN PLAY AREAFLOORINGSEALED CONCRETERECESSED WALK-OFF MATMILLWORK(NOTE: NOT ALL FINISHES SHOWN ON THIS SHEET)GENERAL NOTES1. REFER TO ELEVATIONS FOR LOCATION OF ADDITIONAL WALL SURFACE FINISH.2. REFER TO CEILING PLANS FOR CEILING FINISH LOCATION.3. REFER TO GENERAL SHEET G-106 FOR FINISHES.4. ALL FLOOR FINISHES EXTEND TO ADJACENT WALLFLOOR TILE INSTALLATION NOTES1. ALL CONCRETE FLOORS MUST BE TESTED FOR MOISTURE AND PH PRIOR TO INSTALLATION.2. REFER TO SPECIFICATIONS FOR MOISTURE AND PH LEVEL TOLERANCES.3. SUBSTRATE MUST BE FLAT WITHIN THE EQUIVALENT OF 1/8" IN 10'-0".4. SUBSTRATE MUST BE FREE OF ADHESIVE, SEALERS, PAINT, COATINGS, FINISHES, DIRT, FILM FORMING CURING COMPOUNDS, OR OTHER SUBSTANCES THAT MAY AFFECT THE ADHESION OF THE FLOORING.5. DO NOT INSTALL FLOOR TILE BEFORE ALL OTHER TRADES ARE FINISHED.6. ALL MATERIALS MUST BE ON SITE IN THE ROOM WHERE THEY WILL BE INSTALLED 48 HOURS BEFORE INSTALLATION. TILE MUST BE STORED BEHIND TEMPORARY CONSTRUCTION WALL.7. CLOSE SPACES TO TRAFFIC 12 HOURS BEFORE INSTALLATION AND 24 HOURS AFTER INSTALLATION IS COMPLETE.5. PAINT ALL JOIST AND EXPOSED SURFACES ABOVE WITH DRY FALL PAINT500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 10:57:45 AM1-LD-A701PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH PLAN AND SCHEDULE - NEW LOADINGDOCK07-14-2017S12014NNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUND 1/4" = 1'-0"1FINISH PLAN - NEW LOADING DOCKFINISH SCHEDULE - LOADING DOCKRM. NO. ROOM NAME AreaFLOORBASEWALL FINISHESCEILINGNOTESNorth Finish East Finish South Finish West FinishLD-1 LOADING DOCK 1263 SF SEALED CONCRETE - S1 VINYL - B2 PAINTPAINTPAINTPAINTEXPOSED CORNER GUARDS TO 60" A.F.F. ON ALL WALL CORNERS / PAINTALL EXPOSED STRUCTURE WITH DRY FALL PAINTLD-2 RESTROOM55 SFVCT - V1VINYL - B2 FRP/PAINT - W2 FRP/PAINT - W2 FRP/PAINT FRP/PAINTPAINT FRP TO 48" AFFLD-3 COOLER85 SFN/AN/A N/AN/AN/AN/AN/A PREFINISHED COOLER PACKAGELD-4 HVAC42 SF SEALED CONCRETE - S1 VINYL - B2 PAINTPAINTPAINTPAINTEXPOSED USE PLYWOOD BACKER BOARD FOR ALL WALL MOUNTED ITEMSLD-5 BADGING559 SFCARPETVINYL - B2 PAINTPAINTPAINTPAINTCEILING TILESLD-6 OFFICE211 SFCARPETVINYL - B2 PAINTPAINTPAINTPAINTCEILING TILESLD-7 RESTROOM50 SFCERAMIC TILE - T8 TILE - T9 TILE - T5, T6, &T7TILE - T5, T6, & T7 TILE - T5, T6, & T7 TILE - T5, T6, & T7 PAINTLD-8 RECEPTION120 SFCERAMIC TILE - T8 TILE - T9 PAINTPAINTPAINTPAINTCEILING TILESLD-9 STORAGE72 SFCARPETVINYL - B2 PAINTPAINTPAINTPAINTCEILING TILESLD-10 INTERVIEW70 SFCARPETVINYL - B2 PAINTPAINTPAINTPAINTPAINTLD-11 HVAC104 SF SEALED CONCRETE - S1 VINYL - B2 PAINTPAINTPAINTPAINTEXPOSEDLD-12 SHOWER67 SFCERAMIC TILE - T8 TILE - T9 TILE - T5, T6, &T7TILE - T5, T6, & T7 TILE -T5, T6, & T7 TILE - T5, T6, & T7 PAINT FULL HEIGHT WALL TILE IN SHOWER AREALD-13 RESTROOM53 SFCERAMIC TILE - T8 TILE - T9 TILE - T5, T6, &T7TILE - T5, T6, & T7 TILE - T5, T6, & T7 TILE - T5, T6, & T7 PAINTLD-14 CORRIDOR333 SFCERAMIC TILE - T8 TILE - T9 PAINTPAINTPAINTPAINTCEILING TILESLD-15 ARMS107 SFVCT - V1VINYL - B2 PAINTPAINTPAINTPAINTCEILING TILESLD-16 IT44 SF SEALED CONCRETE - S1 VINYL - B2 PAINTPAINTPAINTPAINTEXPOSED USE PLYWOOD BACKER BOARD FOR ALL WALL MOUNTED ITEMSLD-17 STORAGE25 SFVCT - V1VINYL - B2 PAINTPAINTPAINTPAINTCEILING TILESLD-18 OFFICE108 SFCARPETVINYL - B2 PAINTPAINTPAINTPAINTCEILING TILESLD-19 OFFICE108 SFCARPETVINYL - B2 PAINTPAINTPAINTPAINTCEILING TILESLD-20 CHIEF190 SFCARPETVINYL - B2 PAINTPAINTPAINTPAINTCEILING TILESLD-21 BREAK ROOM239 SFCERAMIC TILE - T8 TILE - T9 PAINTPAINTPAINTPAINTCEILING TILESLD-22 FIRE RISER ROOM 21 SF SEALED CONCRETE - S1 VINYL - B2 PAINTPAINTPAINTPAINTEXPOSEDREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 45 09-22-2017 ADDENDUM 544555CONFORMED SET97
31-LD-A72121-LD-A7213' - 0"2' - 0"2' - 6"2' - 6"3' - 3"DISHWASHER - PROVIDED BY OWNER312452' - 0"2' - 6"2' - 0"3' - 9"2' - 6"1' - 8"2' - 10"111322674' - 2"812' - 1"MIN.3' - 0"4102' - 8"11991023' - 0"3' - 0"3' - 0"2' - 1"167114' - 2"6"14121264OPEN TO BEYONDBREAK ROOM LEGEND#1234567SOLID SURFACE COUNTER TOPS WITH 4" SOLID SURFACE SIDE AND BACK PLASH8PLASTIC LAMINATE BASE CABINETS910EXISTING WALLNEW FULL HEIGHT WALLNEW HALF HEIGHT WALLNOTE:REFER TO REFER TO FINISH SCHEDULE FOR MATERIALS USEDPLASTIC LAMINATE WALL CABINETSPAINT FINISH - REFER TO FINISH SCHEDULEUNDERMOUNT SINK WITH ADA FAUCET -REFER TO PLUMBINGADJUSTABLE PLASTIC LAMINATE SHELVES ON HEAVY DUTY BRACKETS AND STANDARDS.PLASTIC LAMINATE STORAGE CUBBIESALUMINUM WINDOW FRAME, REFER TO ARCHITECTURAL WINDOW SCHEDULEPLASTIC LAMINATE FINISHED END PANEL TO MATCH CABINETSBLACK POWDER COAT STEEL TABLE LEG SUPPORT11LCD MONITORS ON WALL MOUNT BRACKET12BRUSH GROMMET PANEL THROUGH SOLID SURFACE TOPS (TYPICAL OF 4)OPEN3' - 3"2' - 0"2' - 10"9' - 0"128' - 1"91-LD-A721771' - 6"1' - 0"12" X 18" STORAGE CUBBIES5' - 5"(4) 21" CABINETSTYP13' - 0"1' - 9"2' - 4"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:10:22 PM1-LD-A711PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINTERIOR ELEVATIONS - NEW LOADING DOCK07-14-2017S12014 1/2" = 1'-0"1ELEVATION AT BREAK ROOM NORTH 1/2" = 1'-0"2ELEVATION AT BREAK ROOM EAST 1/2" = 1'-0"3ELEVATION AT BREAK ROOM SOUTH 1/2" = 1'-0"4ELEVATION AT BREAK ROOM WESTORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 4 1/2" = 1'-0"5MILLWORK - BADGING OFFICE4CONFORMED SET98
#136" GRAB BAR242" GRAB BAR3BABY CHANGING TABLEa. SOLID SURFACE BABY CHANGING TABLE WITH INTEGRAL 4" FRONT EDGEb. STAINLESS STEEL RECESSED BABY CHANGING STATIONc. SURFACE MOUNTED ADA CHANGING STATION4WALL/ FLOOR MOUNTED TOILET - FLUSH VALVE ON OPEN SIDE OF SPACE IN ALL ADA STALLS - REFER TO PLUMBING5TOILET PAPER DISPENSERa. RECESS MOUNTED JUMBO TISSUE DISPENSERb. RECESS MOUNTED JUMBO TISSUE DISPENSER WITH SANITARY NAPKIN DISPOSALc. NOT USEDd. NOT USEDe. PARTITION/WALL MOUNTED JUMBO DISPENSER7SANITARY NAPKIN DISPOSALa. SHARED PARTITION MOUNTEDb. PARTITION SURFACE MOUNTEDc. RECESSED8MIRRORa. 24" X 36" WALL MOUNTEDb. 24" X 48" WALL MOUNTEDc. 18" X 36" WALL MOUNTED9WALL MOUNTED URINAL10SOLID SURFACE COUNTER WITH 1 1/2" INTEGRAL FRONT EDGE. COUNTER MOUNTED AT 5'-0" AFF.11SINKS - REFER TO PLUMBING & ELECTRICAL DRAWINGSa. ADA SINGLE SOLID SURFACE TROUGH SINK WITH TOUCHLESS HANDWASHING CONTROLb. CONTINUOUS SOLID SURFACE TROUGH SINK AND 2 TOUCHLESS WASH BAR. c. CONTINUOUS SOLID SURFACE TROUGH SINK AND 3 TOUCHLESS WASH BAR. d. STANDARD ADA COMPLIANT WALL MOUNTED SINK WITH ADA FAUCET CONTROLSe. ADA COMPLIANT DROP IN SINK AND FAUCETRESTROOM LEGEND12ADA WALL MOUNTED SOAP DISPENSER13ADA WALL MOUNTED DRYERADA COMPLIANT SHOWER SEAT14SHOWER CURTAIN AND ROD15PLASTIC LAMINATE TALL CABINET1617MOP SINK WITH WALL MOUNTED MOP CLIPS18HI / LOW ADA DRINKING FOUNTAINS19WALL MOUNTED COAT HOOKS20ADA RESTROOM WALL SIGNAGE21WALL TILE - REFER TO SHEET G106 FOR FINISHa. FIELD TILEb. ACCENT TILEc. BULLNOSE TILEd. COVE BASE TILE 1. REFER TO SHEET G111 FOR ADA SPECIFICATIONS.2. ALL FIELD WALL TILE GROUT LINES TO ALIGN WITH FLOOR GROUT LINES. 3. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.GENERAL NOTES22TOILET PARTITION23PARTITION MOUNTED COAT HOOKXX24NAPKIN/TAMPON VENDOR6PLASTIC LAMINATE COUNTER WITH 4" BACKSPLASH ON 3 SIDES. COLOR TBD.8C21d21c21b21aT9T5T6T7PAINT2' - 10"5' - 0"4' - 0"2"4"9"9"9"9"6"1211D1245e11d8c1312FRPVINYL BASEPAINT2' - 10"3' - 0"1' - 7"4' - 0"5' - 0"3' - 4"131211eADA SHOWER, WITH GRAB BARS AND SEAT, REFER TO PLUMBING4"21d21a21a8c71-LD-A72161-LD-A72115146' - 2"2' - 10"T9T5T621bT53' - 4"1' - 5"3' - 10"21cT71245aLD121921d21a21b21aT8T5T6T51' - 7"3' - 0"3' - 10"5' - 2"21cT719LD131245b21a21c21b21a21d2"4"PAINTT9T5T6T71' - 7"3' - 0"4' - 0"5' - 0"11e8c131221c21b21a21d16PAINTT9T5T6T72' - 10"3' - 3"4' - 0"4' - 0"1245eFRPVINYL BASEPAINT5' - 0"4' - 0"1' - 7"3' - 0"1' - 0"FRPVINYL BASEPAINT9' - 0"11d8c1312LD2FRPVINYL BASEPAINT9' - 0"4' - 0"2' - 10"3' - 0"21d21a21c21bT9T5T6T7PAINT4' - 0"5' - 0"21c21b21a21d2PAINTT9T5T6T79' - 0"1' - 0"3' - 6"4' - 0"1' - 7"3' - 0"15B412411D21a21dPAINTT9T55' - 0"5b9"3' - 3"1' - 7"2' - 10"3' - 0"6"1' - 0"2' - 0"8C1212411e1221d21a21b8c21aT9T5T6T51' - 7"2' - 10"1' - 0"3' - 0"4' - 0"5' - 0"5a21cT711e8c1321d21a21b21a19T9T5T5T63' - 10"2' - 10"9' - 0"21cT71245b11e1221D21c21b21a16PAINTT9T5T6T71' - 7"3' - 0"4' - 0"5' - 0"2' - 10"1321c21b21a21d162' - 0"7' - 0"2' - 0"PAINTT9T5T6T74' - 0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:11:56 PM1-LD-A712PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINTERIOR ELEVATIONS - RESTROOMS - NEWLOADING DOCK07-14-2017S12014 1/2" = 1'-0"5BADGING RESTROOM 1/2" = 1'-0"1LOADING DOCK RESTROOM 1/2" = 1'-0"9POLICE STATION SHOWER 1/2" = 1'-0"11POLICE STATION SHOWER 1/2" = 1'-0"15POLICE STATION RESTROOM.. 1/2" = 1'-0"13POLICE STATION RESTROOM 1/2" = 1'-0"2LOADING DOCK RESTROOM. 1/2" = 1'-0"3LOADING DOCK RESTROOM... 1/2" = 1'-0"4LOADING DOCK RESTROOM.. 1/2" = 1'-0"6BADGING RESTROOM. 1/2" = 1'-0"7BADGING RESTROOM.. 1/2" = 1'-0"8BADGING RESTROOM... 1/2" = 1'-0"10POLICE STATION SHOWER 1/2" = 1'-0"12POLICE STATION SHOWER 1/2" = 1'-0"14POLICE STATION RESTROOM. 1/2" = 1'-0"16POLICE STATION RESTROOM...REVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET99
PROVIDE ADA PIPE COVER PROTECTION6"2' - 4" CLEARSOLID SURFACE COUNTER WITH INTEGRAL FRONT EDGE1/2"FLOOR FINISH ASSCHEDULEDWALL FINISH AS SCHEDULEDADA COMPLIANT FAUCET SETUNDERMOUNT SINK, COLOR TO BE DETERMINED. REFER TO PLUMBINGMIRROR AT ADA HEIGHT REFER TO ADA SPECIFICATION SHEET3"1/4"PLASTIC LAMINATE ON ALL EXPOSED SURFACESCABINET DOOR AND DRAWER PULLS TO BE BRUSHED CHROMEADJUSTABLE PLAS. LAM. SHELFCABINET INTERIORS TO BE WHITE PLAS. LAM. FINISH, TYP.BASE AS SCHEDULEDSOLID SURFACE COUNTER ON TOP WITH EDGE NOSE AND 4" BACKSPLASH2' - 10"6"PREFINISHED METAL SHELF BRACKETS AND SUPPORTS PLAS. LAM. SHELF4" SOLID SURFACE BACK & SIDE SPLASHPLASTIC LAMINATE ON ALL EXPOSED SURFACESCABINET INTERIORS TO BE PLAS. LAM. FINISH, TYP.PULL TO BE BRUSHED CHROMESOLID SURFACE COUNTER ON TOP WITH EDGE NOSE AND 4" BACKSPLASH4" SOLID SURFACE BACK & SIDE SPLASH5/8" CEMENTITIOUS BOARD AT WET WALL AND 5/8" GYPSUM BOARD ON 3 5/8" METAL STUD PARTITIONFIXED PANELDISPOSAL, INSINKERATOR-BADGER 500, 1/2 HP MOTORSTAINLESS STEEL FAUCET BY MOEN OR EQUALUNDERMOUNT STAINLESS STEEL SINK, REFER TO PLUMBING.1 1/2"6"2' - 2 1/2"2' - 6"1' - 8"2' - 10"PLASTIC LAMINATE ON ALL EXPOSED SURFACES 1/4" PLYWOOD BACKBOARDSHELF SUPPORT PINSCABINET INTERIORS TO BE PLAS. LAM., TYP.CABINET DOOR AND DRAWER PULLS TO BE BRUSHED CHROMEADJUSTABLE PLAS. LAM. SHELFREF: DEPTH7' - 0"WALL COVERINGREFER TO SCHEDULEPLASTIC LAMINATE ON ALL EXPOSED SURFACESDRAWER PULLS TO BE BRUSHED CHROMEBASE AS SCHEDULED4"9 1/2"1/4"6"1/4"6"1/4"6"SOLID SURFACE COUNTERTOP WITH 1 1/2" SELF EDGE CABINET INTERIORS TO BE PLAS. LAM. FINISH, TYP.SOLID SURFACE COUNTER ON TOP WITH EDGE NOSE AND 4" BACKSPLASH4" SOLID SURFACE BACK & SIDE SPLASH5/8" CEMENTITIOUS BOARD AT WET WALL AND 5/8" GYPSUM BOARD ON 3 5/8" METAL STUD PARTITIONPLASTIC LAMINATE ON ALL EXPOSED SURFACES 1/4" PLYWOOD BACKBOARDSHELF SUPPORT PINSCABINET INTERIORS TO BE PLAS. LAM., TYP.CABINET DOOR AND DRAWER PULLS TO BE BRUSHED CHROMEADJUSTABLE PLAS. LAM. SHELFREF: DEPTH7' - 0"WALL COVERINGREFER TO SCHEDULE2' - 10"PROVIDE BLOCKING IN WALLCABINET INTERIORS TO BE PLAS. LAM. FINISH, TYP.SOLID SURFACE COUNTER TOP WITH EDGE NOSE AND 4" BACKSPLASH4" SOLID SURFACE BACK & SIDE SPLASH5/8" CEMENTITIOUS BOARD AT WET WALL AND 5/8" GYPSUM BOARD ON 3 5/8" METAL STUD PARTITIONWALL COVERINGREFER TO SCHEDULE1/4"6"2' - 1"2' - 10"BASE AS SCHEDULEDPLAS. LAM. ON ALL EXPOSED SURFACESSHELF SUPPORT PINSCABINET INTERIORS TO BE PLAS. LAM. FINISH, TYP.PULL TO BE BRUSHED CHROME, TYP.ADJUSTABLE PLAS. LAM. SHELVING (5)SCRIBE TO WALL34" MIN - 48" MAX4"6'-8".7'-0" .CABINET INTERIORS TO BE PLAS. LAM. FINISH, TYP.SOLID SURFACE COUNTER ON TOP WITH EDGE NOSE AND 4" BACKSPLASH4" SOLID SURFACE BACK & SIDE SPLASH5/8" CEMENTITIOUS BOARD AT WET WALL AND 5/8" GYPSUM BOARD ON 3 5/8" METAL STUD PARTITIONPLASTIC LAMINATE ON ALL EXPOSED SURFACES 1/4" PLYWOOD BACKBOARDSHELF SUPPORT PINSCABINET INTERIORS TO BE PLAS. LAM., TYP.CABINET DOOR AND DRAWER PULLS TO BE BRUSHED CHROMEADJUSTABLE PLAS. LAM. SHELFREF: DEPTH7' - 0"WALL COVERINGREFER TO SCHEDULE2' - 10"PLASTIC LAMINATE ON ALL EXPOSED SURFACESCABINET INTERIORS TO BE WHITE MELAMINE FINISH, TYP.BASE AS SCHEDULED1/4"PULL TO BE BRUSHED CHROME, TYP.6"SOLID SURFACE COUNTER TOP WITH EDGE NOSE AND 4" BACKSPLASHPROVIDE BLOCKING IN WALL4" SOLID SURFACE BACK & SIDE SPLASH2' - 4"2' - 1"BLACK POWDER COAT STEAL LEGS PLYWOOD SECURED TO SUPPORTSCOUNTER SUPPORT BRACKET8"6"6"6"1 1/2"PROVIDE BLOCKING IN WALLCABINET INTERIORS TO BE PLAS. LAM. FINISH, TYP.4" SOLID SURFACE BACK & SIDE SPLASH3' - 3"2' - 0"2' - 10"4"PLASTIC LAMINATE ON ALL EXPOSED SURFACES 1/4" PLYWOOD BACKBOARDCABINET INTERIORS TO BE PLAS. LAM., TYP.CABINET SURFACE TO BE PLAS. LAM., TYP.8' - 1"SOLID SURFACE COUNTER ON TOP WITH EDGE NOSE CABINET DOOR PULLS TO BE BRUSHED CHROME12" X 18" OPEN CUBBIES 1' - 6"PROVIDE BLOCKING FOR SHELVING1' - 6"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/13/2017 2:12:55 PM1-LD-A721PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH DETAILS - MILLWORK - NEW LOADINGDOCK07-14-2017S12014 1 1/2" = 1'-0"6SINK AT SHOWER ROOMS 1 1/2" = 1'-0"1BASE CABINET W/ SHELVES 1 1/2" = 1'-0"2BASE CABINET AT SINK 1 1/2" = 1'-0"3BASE DRAWER CABINET 1 1/2" = 1'-0"7COUNTER @ LOBBY 1 1/2" = 1'-0"5STORAGE CABINET 1 1/2" = 1'-0"4UPPER/LOWER CABINET 1 1/2" = 1'-0"8COUNTER TOP SUPPORTREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 4 1" = 1'-0"9MILLWORK SECTIONORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANNEW LOADING DOCK BUILDINGOUTBOUNDF.I.S. / CUSTOMSINBOUND4CONFORMED SET100
DEMOLISH 48" HIGH RAISED PLATFORMDEMOLISH 48" HIGH RAISED PLATFORMDEMOLISH EXISTING LIFTDEMOLISH EXISTING STAIRSDEMOLISH EXISTING STAIRSLOWER EXISTING ELEVATOR STOP TO NEW FINISHED FLOOR GRADEDEMOLISH EXISTING ROLL UP DOOR AND MAN DOORDEMOLISH EXISTING WALLSDEMOLISH EXISTING OFFICEEXISTING COOLER FREEZER TO REMAINDEMOLISH EXISTING WALLDEMOLISH EXISTING STAIRSOVERHEAD CANOPY TO REMAINDEMOLISH EXISTING WALL AND DOOR41-ELD-A501DEMOLISH 48" RAISED PLATFORMREMOVE EXISTING SODA RACK AND REINSTALL AFTER NEW WALL IS CONSTRUCTEDRELOCATED EXPOSED CONDUIT21-ELD-A101DEMOLITION PLAN LEGENDITEMS TO DEMOLISHITEMS TO REMAIN500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:40:30 PM1-ELD-A100PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADEMOLITION PLAN - EXISTING LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1ENLARGED DEMOLITION PLAN - EXISTING LOADING DOCKNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANF.I.S. CUSTOMSTERMINAL BTERMINAL AEXISTING LOADING DOCKREVISIONS# DATE DESCRIPTION BYCONFORMED SET101
1-ELD-A2011EXISTING LOADING DOCKB1-13ELEVATOR 5B1-14RECEIVING AREAB1-11OFFICEB1-122' - 3 1/2"6' - 4"5' - 10"9' - 11"30' - 0"10' - 4"29' - 7"33333C3C2B3126' - 9 1/2"6' - 0"6' - 9 1/2"23EXISTING WALK IN COOLER TO REMAINEXISTING SHELVING TO REMAINLOWER LEVEL0'-0"FINISH LINE = 0'-0" ARCHITECTURAL AND 51.00' CIVIL FINISH FLOOR0'-0"FINISH FLOOR0'-0"3EXISTING CORRIDORB1-15EXISTING TRELLIS TO REMAIN - ABOVE41-ELD-A501FINISH FLOOR0'-0"451-ELD-A501231-ELD-A50144PATCH, REPAIR, REPLACE AND REFINISH ANY AREAS EFFECTED BY DEMOLITION OF PLATFORMSLOPEEQEQ21-ELD-A101NEW STEEL COLUMN -REFER TO STRUCTURALWALL TYPE LEGENDNEW STUD WALLEXISTING WALLEXISTING LOADING DOCK KEYNOTES#1EXISTING ELEVATOR HAS (3) STOPS 1. GRADE OF THE EXTERIOR 2. 48" ABOVE GRADE ON THE INTERIOR AND 3. 2ND FLOOR OF TERMINAL B.UNDER ALLOWANCE ITEM #1, ELEVATOR CONTRACTOR SHALL ADJUST STOP #2 INTERIOR DOOR OPENING TO STOP AT SAME GRADE LEVEL AS STOP #1.2CONTRACTOR TO DEMOLISH 48" RAISED PLATFORM, LOADING DOCK LIFT AND POUR NEW CONCRETE FLOOR3ADD NEW ALUMINUM PANELS - MATCH EXISTING FINISH AND PANEL STYLE4REBUILD LOWER 48" OF EXISTING WALL WHERE RAISED PLATFORM HAS BEEN DEMOLISHED5POUR NEW CONCRETE SLAB WHERE PLATFORM WAS DEMOLISHEDNEW OPENING7'-6"EXISTING CEILING8'-0" V.I.F.CUT EXISTING WALL8'-1"EXISTING PORTION OF WALL TO REMAIN. ALL EXISTING CONDUIT, FIRE SPRINKLER PIPES AND OTHER WALL PENETRATIONS TO REMAINDEMOLISH EXISTING WALL TO 8'-1" A.F.F. IN CORRIDOR AND 4'-0" IN LOADING DOCK AREA . V.I.F.INSTALL NEW 4X4X1/4" STEEL COLUMN AS SHOWN ON FLOOR PLAN - PAINTEDINSTALL NEW CONTINUOUS METAL STUD BOX HEADER IN OPENING - REFER TO STRUCTURALEXISTING 2ND FLOOR METAL DECKEXISTING STEEL BEAMEXISTING CEILING TO REMAINNEW CONCRETE FLOOR SLAB - REFER TO STRUCTURALNEW 5/8" GYPSUM WALL BOARD - PAINTED -MATCH ADJACENT COLOR AND FINISH1-ELD-A1013BRACING TO EXISTING STEEL BEAM - REFER TO STRUCTURAL FOR DETAILS AND ATTACHMENT(2) 6" 18 GAUGE CONTINUOUS METAL STUDS(2) 3 5/8" 18 GAUGE CONTINUOUS METAL STUDS TOP AND BOTTOMNEW 4 X4X1/4" STEEL COLUMN - WRAP WITH CONTINUOUS HAT CHANNELS AND GYPSUM WALL BOARDNEW 1/4" STEEL PLATE ON TOP OF NEW COLUMN - ATTACH NEW METAL STUD BOX HEADER TO PLATEEXISTING CEILING TO REMAIN - INSTALL NEW TRIM PIECE TO LENGTH OF NEW WALLSREPAIR PATCH AND PAINT AREA AT EXISTING WALL CONNECTIONBRACE TO EXISTING STEEL BEAM PER STRUCTURAL DETAILS500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 11:00:51 AM1-ELD-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFLOOR PLAN - EXISTING LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1FLOOR PLAN - EXISTING LOADING DOCKORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTH 1" = 1'-0"2SECTION AT EXISTING LOADING DOCK 3" = 1'-0"3METAL STUD BOX HEADERREVISIONS# DATEDESCRIPTIONBYCONFORMED SET102
EXISTING LOADING DOCKB1-13ELEVATOR 5B1-14RECEIVING AREAB1-11OFFICEB1-129' - 0"EXISTING CEILING AND LIGHTING TO REMAIN EXISTING CEILING AND LIGHTING TO REMAIN REFER TO ELECTRICAL PLANS FOR LIGHTINGEXPOSED CEILINGEXISTING CEILING AND LIGHTING TO REMAIN / AREA NOT IN CONTRACTEXISTING CEILING AND LIGHTING TO REMAINNEW GYPSUM WALL BOARD CEILING AND SINGLE 2X4 FIXTURE REFER TO ELECTRICAL DRAWINGS41-ELD-A501NEW WALL HEADER TO 6" BELOW EXISTING CEILING IN CORRIDOR7' - 6"V.I.F.11-ELD-A50121-ELD-A101REFLECTED CEILING PLAN LEGEND2 X 4 LED LIGHTING FIXTURECEILING SUPPLY DIFFUSER SEE MECHANICAL DWGS.GYP. BOARD CEILING ACCESSEXIT SIGN, ARROW INDICATES EXIT DIRECTION SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATIONINDICATES FINISHED GYP. BOARD CEILING OR SOFFITEMERGENCY LIGHTS RE: ELECTRICAL DRAWINGS2 X 2 LAY-IN ACOUSTICAL TILE IN T-BAR GRID. 1. FIXTURES, CONDUITS, DUCTWORK, PIPING, ETC. SHALL BE INSTALLED AS HIGH AS POSSIBLE.2. ADDITIONAL DIRECTIONAL EXIT SIGNS MAY BE REQUIRED. CONTRACTOR TO VERIFY QUANTITIES AND COORDINATE LOCATIONS IN THE FIELD WITH THE FIRE DEPARTMENT FIRE INSPECTOR.3. EMERGENCY LIGHTING SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE.4. MECHANICAL DIFFUSERS TO MATCH ADJACENT CEILING TILE.5. SEE ELECTRICAL DRAWINGS FOR ALL LIGHT FIXTURES 6. INSTALL NEW SPEAKERS AT EXISTING SPEAKER LOCATIONS IN NEW WORK AREA -TYPICALREFLECTED CEILING GENERAL NOTESRECESSED LED CAN LIGHTINGSURFACE MOUNTED EXTERIOR WALL PACKFIRE SPRINKLER HEADPREFINISHED METAL SOFFIT PANELPREFINISHED HANGING PERFORATED METAL PANELCEILING RETURN DIFFUSER SEE MECHANICAL DWGS.INTERIOR WALL HEIGHT LEGENDFULL HEIGHT WALL ATTACHED TO DECKWALL TO EXTEND TO 6" ABOVE FINISHED CEILING - BRACE TO STRUCTURE ABOVE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:41:09 PM1-ELD-A102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREFLECTED CEILING PLAN - EXISTING LOADINGDOCK07-14-2017S12014 1/4" = 1'-0"1REFLECTED CEILING PLAN - EXISTING LOADING DOCKNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET103
6' - 6 1/2"1' - 0"6' - 6 1/2"ADD NEW METAL SIDING -MATCH EXISTING ADJACENT FINISH AND COLORADD NEW ALUMINUM SIDING - MATCH EXISTING ADJACENT FINISH AND COLOREXISTING TRELLIS TO REMAINREMOVE DOWNSPOUT FROM FRONT OF TRELLIS AND PATCH DOWNSPOUT HOLE. EXISTING TRELLIS DOWNSPOUTV.I.F.15' - 6"11' - 0"EXISTING ELEVATOR DOOR TO REMAIN11' - 0"16' - 0"1' - 6"REPLACE EXISTING THROUGH WALL VENTREMOVE EXISTING METAL WALL PANEL UP TO FIRST HORIZONTAL JOINT AND REPLACE WITH NEW METAL PANELS. MATCH EXISTING PANEL PATTERN, AND ADJACENT COLORREMOVE EXISTING METAL WALL PANEL UP TO FIRST HORIZONTAL JOINT AND REPLACE WITH NEW METAL PANELS. MATCH EXISTING PANEL PATTERN, AND ADJACENT COLORREMOVE EXISTING METAL WALL PANEL UP TO FIRST HORIZONTAL JOINT AND REPLACE WITH NEW METAL PANELS. MATCH EXISTING PANEL PATTERN, AND ADJACENT COLOREXISTING SPLIT AC UNITS TO REMAIN - REMOVE AND REINSTALL WALL DISCONNECTS AND WALL REFRIGERANT PIPINGEXISTING CONDUIT LINE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:41:25 PM1-ELD-A201PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAEXTERIOR ELEVATION - EXISTING LOADING DOCK07-14-2017S12014 1/4" = 1'-0"1EXISTING LOADING DOCK - SOUTH ELEVATIONORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDEXTERIOR PERSPECTIVE VIEW 1REVISIONS# DATE DESCRIPTION BYNEW SLABNEW METAL WALL PANELSCONFORMED SET104
EXISTING ELEVATOR PIT WALLTO BE MODIFIED FOR NEW OPENING NEW CONCRETE FLOOR SLABREFER TO FLOOR PLANREINSTALLED EXISTING SHAFT DOORREINSTALLED EXISTING SHAFT DOOR THRESHOLDREINSTALLED EXISTING SHAFT DOOR JAMBREINSTALLED EXISTING SHAFT DOOR1" GYPSUM WALLBOARD LINER PANEL2 1/2" J - RUNNER WITH UNEQUAL LEGS(2) LAYERS 1/2" GYPSUM BOARD - MATCH EXISTING CONSTRUCTION UL U4382 1/2" J - RUNNER WITH UNEQUAL LEGSEXISTING SHAFT WALL AND LINER TO REMAIN2 1/2" C-T STUDSREINSTALLED EXISTING SHAFT DOORNEW OR EXISTING 1" GYPSUM WALLBOARD LINER PANEL2 1/2" J - RUNNER WITH UNEQUAL LEGSNEW OR EXISTING (2) LAYERS 1/2" GYPSUM BOARD - MATCH EXISTING CONSTRUCTION UL U4382 1/2" C-T STUDSEXISTING FOOTING TO REMAINNEW CONCRETE SLAB;REFER TO STRUCTURALNEW 10 MIL VAPOR BARRIEROVER TERMITE TREATEDCOMPACTED FILLNEW 3 5/8" METAL STUD WALL FRAMING WITH 5/8" GYPSUM BOARD - BOTH SIDESEXISTING CONCRETE FLOOR SLAB TO BE REMOVEDEXISTING CONCRETE FOUNDATION TO BE REMOVEDEXISTING SUSPENDED CEILING AND GRID TO REMAIN, MODIFY AS REQUIRED FOR NEW WALL EXISTING FLOOR STRUCTURE TO REMAIN. EXISTING STRUCTURAL BEAM TO REMAIN2x6 WOOD WALL BUMPER 4"VINYL BASE2x4 WOOD WALL BUMPER FRP WALL PANELASSUMED EXISTING FOUNDATION - V.I.F.METAL SUDS500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:41:41 PM1-ELD-A501PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADETAILS - EXISTING LOADING DOCK07-14-2017S12014 1 1/2" = 1'-0"3EXISTING ELEVATOR SILL DETAIL 1 1/2" = 1'-0"1EXISTING ELEVATOR HEAD DETAIL 1 1/2" = 1'-0"2EXISTING ELEVATOR JAMB DETAIL 3/4" = 1'-0"4WALL SECTIONS - EXISTINGLOADING DOCKREVISIONS# DATE DESCRIPTION BYORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDUL U438CONFORMED SET105
1-ELD-A2011B1-13B1-13BB1-12EXISTING LOADING DOCKB1-13OFFICEB1-12RECEIVING AREAB1-11ELEVATOR 5B1-14EXISTING ELECTRICALB1-53EXISTING ITB1-52CORRIDORB1-51EXISTING CORRIDORB1-15WALL TYPE LEGENDNEW WALLEXISTING WALLDOOR TAG - REFER TO SCHEDULE#NEW MASONRY WALLADD SIGN TO FRONT FACE OF ALL DOORS THAT ENTER INTO SECURE AREAHEIGHT = 18"WIDTH = 18"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:41:59 PM1-ELD-A601PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADOOR SCHEDULE AND KEY PLAN - EXISTINGLOADING DOCK07-14-2017S12014 1/4" = 1'-0"1KEYPLAN - EXISTING LOADING DOCKDOOR SCHEDULE - EXISTING LOADING DOCKSAA #CARDREADERDoor # Room NameDoor SizeDoorLabelDetailsFrameHardwareSetCommentsWidth Height Thickness Door Material Door FinishHead Jamb Threshold Material FinishNO B1-12 OFFICE3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORESTAIN2/1-ELD-A602 3/1-ELD-A602HOLLOW METAL PAINT 11YES B1-13 EXISTINGLOADING DOCK6' - 0" 7' - 0" 1 3/4" HOLLOW METALPAINT AUTHORIZEDPERSONNELONLY4/1-ELD-A602 5/1-ELD-A602 6/1-ELD-A602 HOLLOW METAL PAINT 16YES B1-13B EXISTINGLOADING DOCK6' - 0" 7' - 0" 1 3/4" HOLLOW METALPAINT2/1-ELD-A602 3/1-ELD-A602HOLLOW METAL PAINT 17ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTHREVISIONS# DATE DESCRIPTION BYGENERAL NOTE: IF DOOR DOES NOT HAVE A CARD READER THEN IT WILL REQUIRE A LOCK AND KEY. KEYING WILL REQUIRE COORDINATION WITH S.A.A.CONFORMED SET106
7' - 0"2"7' - 2"2"3' - 0"2"3' - 4"SINGLE FLUSH HOLLOW METAL DOOR4"CARD READER3' - 0"2"DOUBLE HOLLOW METAL DOOR2"CARD READER3' - 0"2"DOUBLE HOLLOW METAL DOOR7' - 0"7' - 4"5/8" GYPSUM BOARD BOTH SIDES3 5/8" METAL STUDS PER WALL TYPESOLID CORE WOOD DOOR BATT INSULATION REFERTO WALL TYPESHOLLOW METAL FRAME7'-0" A.F.F.5/8" GYPSUMBOARD BOTHSIDESDOUBLE 3 5/8"METAL STUDS PER WALL TYPEHOLLOW METALFRAMESOLID CORE WOOD DOOR BATT INSULATION REFERTO WALL TYPESSEALANT, BOTH SIDESBATT INSULATION. REFER TO WALL TYPE5/8" GYPSUM BOARDMETAL SIDING ON HAT CHANNELSHOLLOW METAL FRAME & DOOR7'-2" A.F.F.6" METAL STUDS PER WALL TYPEEXTERIOR SHEATHINGSEALANT, BOTH SIDESBATT INSULATION. REFER TO WALL TYPE5/8" GYPSUM BOARDMETAL SIDING ON HAT CHANNELSHOLLOW METAL FRAME & DOOR6" METAL STUDS PER WALL TYPEEXTERIOR SHEATHINGDOORHOLLOW METAL DOORFRAMEFLOOR FINISH PER SCHEDULEMETAL THRESHOLD SET IN FULLBET OF MASTIC500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:42:12 PM1-ELD-A602PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADOOR ELEVATIONS AND DETAILS - EXISTINGLOADING DOCK07-14-2017S12014REVISIONS# DATE DESCRIPTION BY 1/2" = 1'-0"1DOOR ELEVATIONS 3" = 1'-0"2INTERIOR DOOR HEAD ELD 3" = 1'-0"3INTERIOR DOOR JAMB ELD 3" = 1'-0"4EXTERIOR HM DOOR HEAD 3" = 1'-0"5EXTERIOR H/M DOOR JAMB 3" = 1'-0"6EXTERIOR H/M THRESHOLD DETAILCONFORMED SET107
UNKUPEXISTING ELECTRICALB1-53EXISTING ITB1-52RECEIVING AREAB1-11OFFICEB1-12EXISTING LOADING DOCKB1-13ELEVATOR 5B1-14EXISTING FLOOR TO REMAINEXISTING CORRIDORB1-15ELEVATOR ROOMB1-17NEW LOADING DOCK ELEVATORB1-161-GE-A7015W2W2NEW CONCRETE SLAB NEW CONCRETE SLAB W2NEW CONCRETE SLAB NEW CONCRETE SLAB PATCH, REPAIR AND PAINT CLOSET / STORAGE AREASW2W2W241-ELD-A501PFPFPFPFPFFINISH LEGENDCARPETCARPET ACCENTCARPET ACCENTVCTTILE FLOORINGTERRAZZO TILETERRAZZO TILE ACCENTTERRAZZO TILE ACCENTCHILDREN PLAY AREAFLOORINGSEALED CONCRETERECESSED WALK-OFF MATMILLWORK(NOTE: NOT ALL FINISHES SHOWN ON THIS SHEET)GENERAL NOTES1. REFER TO ELEVATIONS FOR LOCATION OF ADDITIONAL WALL SURFACE FINISH.2. REFER TO CEILING PLANS FOR CEILING FINISH LOCATION.3. REFER TO GENERAL SHEET G-106 FOR FINISHES.4. ALL FLOOR FINISHES EXTEND TO ADJACENT WALLFLOOR TILE INSTALLATION NOTES1. ALL CONCRETE FLOORS MUST BE TESTED FOR MOISTURE AND PH PRIOR TO INSTALLATION.2. REFER TO SPECIFICATIONS FOR MOISTURE AND PH LEVEL TOLERANCES.3. SUBSTRATE MUST BE FLAT WITHIN THE EQUIVALENT OF 1/8" IN 10'-0".4. SUBSTRATE MUST BE FREE OF ADHESIVE, SEALERS, PAINT, COATINGS, FINISHES, DIRT, FILM FORMING CURING COMPOUNDS, OR OTHER SUBSTANCES THAT MAY AFFECT THE ADHESION OF THE FLOORING.5. DO NOT INSTALL FLOOR TILE BEFORE ALL OTHER TRADES ARE FINISHED.6. ALL MATERIALS MUST BE ON SITE IN THE ROOM WHERE THEY WILL BE INSTALLED 48 HOURS BEFORE INSTALLATION. TILE MUST BE STORED BEHIND TEMPORARY CONSTRUCTION WALL.7. CLOSE SPACES TO TRAFFIC 12 HOURS BEFORE INSTALLATION AND 24 HOURS AFTER INSTALLATION IS COMPLETE.5. PAINT ALL JOIST AND EXPOSED SURFACES ABOVE WITH DRY FALL PAINTKEY NOTES FINISH PLAN#1INSTALL NEW FRP TO EXISTING AND NEW PARTITION FROM FLOOR TO 4'-0" AFF. PROVIDE NEW 4" BASE. PROVIDE 2 X 6 PRIME STOCK OAK WITH SCARF JOINTS, PAINTED TO MATCH PARTITION(3 COATS, REFER TO SPEC). REFER TO NEW WALL SECTION FOR ADDITIONAL INFORMATION.NEW POLY-CRETE(CEMENTITIOUS-URETHANE)PRODUCT THROUGHOUT CORRIDOR AND LOADING DOCK AREA AS SHOWN.2500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt8/24/2017 2:41:24 PM1-ELD-A701PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH PLAN AND SCHEDULE - EXISTING LOADINGDOCK AND NEW LOADING DOCK ELEVATOR07-14-2017S12014 1/8" = 1'-0"1FINISH PLAN - EXISTING LOADING DOCKNNORTHFINISH SCHEDULE - EXISTING LOADING DOCKRM. NO.ROOM NAMEAreaFLOORBASEWALL FINISHESCEILINGNOTESNorth Finish East Finish South Finish West FinishB1-11 RECEIVING AREA644 SF SEALED CONCRETE - SC VINYL - B3 PAINT PAINT PAINT PAINTEXISTINGB1-12 OFFICE86 SFCARPETVINYL - B3 PAINT PAINT PAINT PAINT CEILING TILESB1-13 EXISTING LOADING DOCK678 SF SEALED CONCRETE - SC VINYL - B3 PAINT PAINT PAINT PAINT CEILING TILESB1-14 ELEVATOR 579 SFN/AEXISTING EXISTING EXISTING EXISTING EXISTING EXISTING ELEVATOR FINISHES EXISTING TO REMAIN. REFERTO ARCHITECTURAL PLANS AND SECTIONS FORMODIFICATIONS TO ELEVATOR. REPAIR INTERIORFINISHES AS NECESSARY UPON RECONFIGURATIONOF ELEVATORB1-15 EXISTING CORRIDOR1556 SF EXISTING FLOOR TO REMAIN VINYL - B3 FRP/PAINT -W2PAINT FRP/PAINT -W2FRP/PAINT-W2EXISTING PROVIDE BUMBER GUARD ABOVE BASE. PAINT ALLWALLS OF CORRIDORB1-16 NEW LOADING DOCK ELEVATOR 83 SFDIAMOND PLATE FLOORB1-16A CORRIDOR246 SFVCTVINYLCEILING TILESB1-17 ELEVATOR ROOM34 SFSCVINYL - B3 PAINT PAINT PAINT PAINTNONE1ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDLOADING DOCK ELEVATOR1TYP.TYP.2222REVISIONS# DATEDESCRIPTIONBY3 08-25-2017 ADDENDUM 33CONFORMED SET108
1" [25mm]1 3/8" [36mm]3 13/16" [97mm]13/16" [20mm]1/8" [3mm]TF316114 @ 20"(508mm) O.C.75101PBALCO 75FPE-1gINTERIOR FLOOR TO FLOOR SYSTEMMILL FINISH ALUMINUM BASEw/45MIL EPDM WATER BARRIERAPPROXIMATELY 25% MOVEMENTWB045 X 6"(152mm)CSQF12BELEVATOR DOORBY ELEVATOR INSTALLER8" CMU ELEVATOR SHAFT WALLOUTSIDE CORNER METAL CLIP1/2" SHEATHING OVER METAL FRAMINGVERTICAL EDGE METAL CLIP3/4" PLASTIC LAMINATE PANEL WITH NARROW MAIN RAIL METAL CLIPELEVATOR DOOR HEADBY ELEVATOR INSTALLERS.S. HEADER TRIM8" CMU ELEVATOR SHAFT WALLOUTSIDE CORNER METAL CLIP1/2" SHEATHING OVER METAL FRAMINGVERTICAL EDGE METAL CLIP3/4" PLASTIC LAMINATE PANEL WITH NARROW MAIN RAIL METAL CLIP1/16" VERTICAL REVEAL CLIPELEVATOR DOOR JAMBBY ELEVATOR INSTALLERS.S. JAMB AND HEADERELEVATOR SHAFT WALLCONCRETE FLOOR SLABREFER TO FLOOR PLANELEVATOR DOOR,BY ELEVATOR INSTALLERELEVATOR DOOR THRESHOLD, BY ELEVATOR INSTALLERELEVATOR DOOR JAMB, BY ELEVATOR INSTALLER500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:46:32 PM1-GE-A501PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADETAILS - NEW INTERIOR AND EXTERIORELEVATOR07-14-2017S12014 1 1/2" = 1'-0"2NEW OUTBOUND ELEVATORHEAD DETAIL 1 1/2" = 1'-0"3NEW OUTBOUND ELEVATOR JAMBDETAIL 1 1/2" = 1'-0"4NEW OUTBOUND ELEVATOR SILLDETAILORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDN.T.S.1FLOOR EXPANSION JOINT - OUTBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET109
1-NIE-A7033211-NIE-A7021-NIE-A70231-NIE-A7022111-NIE-A30121-NIE-A3011-NIE-A7031OPH SIMFRITZ TILE FLOORTZ11-NIE-A7031231OPH SIM1-NIE-A7023OPH SIM1-NIE-A7022OPH SIMEQEQEQEQSTAINLESS STEEL CEILINGELEVATOR MFG. STANDARD DOWNLIGHT FIXTURE1-NIE-A7021-NIE-A7023111-NIE-A30121-NIE-A3011-NIE-A70221-NIE-A70261-NIE-A70241-NIE-A7025FOR CAB FINISHES REFER TO DETAIL 1 THIS SHEETELEVATOR ROOMB1-17NEW LOADING DOCK ELEVATORB1-16SEALED CONCRETEDIAMOND PLATE FLOORGENERAL NOTES1. REFER TO ELEVATIONS FOR LOCATION OF ADDITIONAL WALL SURFACE FINISH.2. REFER TO CEILING PLANS FOR CEILING FINISH LOCATION.3. REFER TO GENERAL SHEET G-106 FOR FINISHES.4. ALL FLOOR FINISHES EXTEND TO ADJACENT WALLFLOOR TILE INSTALLATION NOTES1. ALL CONCRETE FLOORS MUST BE TESTED FOR MOISTURE AND PH PRIOR TO INSTALLATION.2. REFER TO SPECIFICATIONS FOR MOISTURE AND PH LEVEL TOLERANCES.3. SUBSTRATE MUST BE FLAT WITHIN THE EQUIVALENT OF 1/8" IN 10'-0".4. SUBSTRATE MUST BE FREE OF ADHESIVE, SEALERS, PAINT, COATINGS, FINISHES, DIRT, FILM FORMING CURING COMPOUNDS, OR OTHER SUBSTANCES THAT MAY AFFECT THE ADHESION OF THE FLOORING.5. DO NOT INSTALL FLOOR TILE BEFORE ALL OTHER TRADES ARE FINISHED.6. ALL MATERIALS MUST BE ON SITE IN THE ROOM WHERE THEY WILL BE INSTALLED 48 HOURS BEFORE INSTALLATION. TILE MUST BE STORED BEHIND TEMPORARY CONSTRUCTION WALL.7. CLOSE SPACES TO TRAFFIC 12 HOURS BEFORE INSTALLATION AND 24 HOURS AFTER INSTALLATION IS COMPLETE.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 11:04:40 AM1-GE-A701PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH PLANS - NEW INTERIOR AND EXTERIORELEVATORS07-14-2017S12014 1/2" = 1'-0"1ENLARGED PLAN - OUTBOUND 1ST FLOOR 1/2" = 1'-0"3ENLARGED PLAN - OUTBOUND EXISTING ELEVATOR 1/2" = 1'-0"4REFLECTED CEILING PLAN - OUTBOUND(ELEVATORS 1 AND 3 SIMILAR) 1/2" = 1'-0"2ENLARGED PLAN - OUTBOUND 2ND FLOOR 1/2" = 1'-0"5ENLARGED PLAN - LOADING DOCK 1ST FLOORFRITZ TILE FLOORTZ1ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBYCONFORMED SET110
EXISTING ITB1-44EXISTING ELECTRICALB1-39EXISTING ITB1-41EXISTING JANITORB1-42EXISTING ELEVATOR ROOMB1-43ELEVATOR 3B1-48EXISTING MENS ROOMB1-383 1/2"14' - 0"11' - 0"EXISTING GATE COUNTERSTO BE REMOVEDEXISTING BAGGAGE BELTTO REMAINEXISTING CONCRETE FLOOR SLAB TO BE REMOVED FOR NEW ELEVATOR PITEXISTING DOOR & FRAME TO BE REMOVED - WALL TO BE INFILLED TO MATCH EXISTING CORRIDORB1-31BREAK ROOMB1-27SECURITY SCREENINGB1-26RESTROOM DEMOLITION TO OCCUR IN PHASE 2 WORKNEW DOOR OPENINGNEW WALL OPENINGG.C. TO VERIFY LOCATION OF UNDERGROUND ELECTRICAL LINE BEFORE START OF DEMOLITION OPERATIONSEXISTING DOWN ESCALATOR TO REMAINEXISTING UP ESCALATOR TO REMAINDNDNEXISTING SUSPENDED SOFFIT TO REMAIN. MODIFY FOR NEW ELEVATOR. REMOVE EXISTING METAL WINGSELEVATOR 3B1-48CORRIDORB2-18EXISTING MECHANICAL ROOMB2-01DEMOLISH EXISTING PORTION OF OVERHEAD SOFFIT TO NEXT CEILING SUPPORT SECTION TO MAKE ROOM FOR NEW ELEVATOR INSTALLATION12' - 0"1' - 6"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:55:50 PM1-NIE-A100PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADEMOLITION PLAN - NEW INTERIOR ELEVATOR07-14-2017S12014 1/4" = 1'-0"1DEMOLITION PLAN - NEW INTERIOR ELEVATORNNORTH 1/4" = 1'-0"2DEMOLITION CEILING PLAN - NEW INTERIOR ELEVATOREXISTING STEEL COLUMN AND WALL SURROUND TO REMAINEXISTING STEEL COLUMN AND WALL SURROUND TO REMAINEXISTING STEEL COLUMN AND WALL SURROUND TO REMAINEXISTING ALUMINUM STOREFRONT TO REMAIN REMOVE EXISTING GLASS GUARDRAIL REMOVE EXISTING GLASS GUARDRAIL NNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET111
EXISTING ITB1-44STORAGEB1-47CORRIDORB1-31EXISTING ELECTRICALB1-39EXISTING ITB1-41EXISTING MENS ROOMB1-38BREAK ROOMB1-27SECURITY SCREENINGB1-26ELEVATOR 3B1-48ELEVATOR 4B1-49EXISTING ELEVATOR ROOMB1-43EXISTING JANITORB1-4213' - 7 1/4"9' - 8"11-NIE-A30121-NIE-A301HOLD7' - 7 5/8"HOLD8' - 4"PLASTIC LAMINATE PANELS OVER 8" REINFORCED (2 HOUR) CMU WALLPLASTIC LAMINATE PANELS OVER EXISTING CMU WALL -REFER TO SHEET 1-NIE-A702 FOR SIMILAR ELEVATIONNEW GATE COUNTERS - PHASE 2 WORKINFILL EXISTING OPENINGTO MATCH EXISTING5' - 6"3A1E1E1E1EB1-31ELEVATOR 3B1-48ELEVATOR 4B1-49EXISTING MECHANICAL ROOMB2-01CORRIDORB2-1811-NIE-A30121-NIE-A3017' - 7 1/2"8' - 4"9' - 8"PLASTIC LAMINATE PANELS OVER CMU WALLPLASTIC LAMINATE PANELS OVER EXISTING ELEVATOR WALLSNEW WALL INFILL TO MATCH EXISTINGNEW ALUMINUM STOREFRONT BY KAWNEER "MODEL TRI FAB 451 " WITH TEMPERED GLAZINGNEW STOREFRONT INFILL28' - 8"NEW STOREFRONT INFILL17' - 11"2' - 8"NEW FLOOR EXPANSION JOINTNEW CONCRETE FLOORREFER TO STRUCTURAL555PLASTIC LAMINATE PANELS OVER 8" REINFORCED (2 HOUR) CMU WALLPLASTIC LAMINATE PANELS OVER EXISTING CMU WALL -REFER TO SHEET 1-NiE-A702 FOR SIMILAR ELEVATIONS1E1E1E1E11-GE-A501G.C. TO VERIFY SIZE OF ELEVATOR SHAFT NEED PER ELEVATOR SELECTED BEFORE DEMOLITION WORK IS STARTED500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 11:06:15 AM1-NIE-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFLOOR PLANS - NEW INTERIOR ELEVATOR07-14-2017S12014 1/4" = 1'-0"1FLOOR PLAN 1ST FLOOR - NEW INTERIOR ELEVATORNNORTH 1/4" = 1'-0"2FLOOR PLAN 2ND FLOOR - NEW INTERIOR ELEVATORNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBYCONFORMED SET112
21-NIE-A301GRADE0'-0"BOTTOM OF PIT-5'-0"2ND FLOOR13'-6"TOP OF CMU26'-0"TOP CEILING29'-6"EXISTING SOFFIT TO REMAIN, MODIFY FOR NEW CONSTRUCTION SUSPENDED CEILING HOISTWAY BEAM - 12'-7" MINIMUM HEIGHT CLEAR FROM 2ND FLOOR LEVEL -G.C. TO VERIFY WITH ELEVATOR MANUFACTURE1/4" HORIZONTAL REVEAL3/4" PLASTIC LAMINATE PANEL WITH NARROW MAIN RAIL METAL CLIP8" 2 HOUR RATED CMUMETAL SOFFITFRITZ TERRAZZO TILE BASENEW CONCRETE FLOOR SLAB TO MATCH EXISTINGEXPANSION JOINT WITH SEALANT AND BACKER RODEXISTING FLOORWATER PROOF CONCRETE ELEVATOR PIT - REFER TO STRUCTURALEXISTING ESCALATOR TO REMAINEXISTING WALL TO REMAINSUSPENDED CEILING EXISTING SOFFIT TO REMAIN, MODIFY FOR NEW CONSTRUCTION 1/4" HORIZONTAL REVEAL3/4" PLASTIC LAMINATE PANEL WITH NARROW MAIN RAIL METAL CLIP8" (2) HOUR RATED VERTICALLY REINFORCED CMU WALL - UL U906(2) RATED ROOF CAP UL D906BOTTOM OF BEAM26'-2"26' - 2"INSTALL NEW PIT LADDERINSTALL NEW SUMP PUMP AND ENCASE IN WATER PROOF CONCRETEREFER TO STRUCTURAL FOR CONCRETE DESIGN11-NIE-A301NEW CONCRETE FLOOR SLAB TO MATCH EXISTINGEXISTING FLOOREXISTING FLOOREXISTING WALLTO REMAINSUSPENDED CEILING 1/4" HORIZONTAL REVEAL3/4" PLASTIC LAMINATE PANEL WITH NARROW MAIN RAIL METAL CLIPELEVATOR SHAFT DOOR JAMBBY ELEVATOR INSTALLER3/4" PLASTIC LAMINATE PANEL WITH NARROW MAIN RAIL METAL CLIPELEVATOR SHAFT DOOR JAMBBY ELEVATOR INSTALLEREXISTING FLOOR STRUCTURETO REMAINNEW FLOOR STRUCTUREREFER TO STRUCTURAL FLOOR EXPANSION JOINT1-GE-A50151-GE-A50121-GE-A50141-GE-A50121-GE-A5014WATER PROOF CONCRETE - REFER TO STRUCTURAL8" 2 HOUR VERTICALLY REINFORCED CMU WALLNEW CONCRETE FLOOR SLAB TO MATCH EXISTINGINSTALL PIT LADDER500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 3/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 11:07:39 AM1-NIE-A301PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL SECTIONS - NEW INTERIOR ELEVATOR07-14-2017S12014 3/4" = 1'-0"1WALL SECTION 1 - NEW INTERIOR ELEVATOR 3/4" = 1'-0"2WALL SECTION 2 - NEW INTERIOR ELEVATORREVISIONS# DATEDESCRIPTIONBYCONFORMED SET113
FLOOR LINE0"LEVEL 213' - 6"10' - 6"12' - 6"ALUMINUM SIGNAGE BAND. REFER TO WAYFINDING DRAWINGS FOR WALL CONNECTION.2' - 6"1' - 0"2' - 6"1' - 0"2' - 9"2' - 9"1' - 0"3' - 0"3' - 0"1' - 0"2' - 6"13' - 8 1/8"BRUSHED STAINLESS STEEL BASE,LAMINATED PANEL SYSTEM, REFER TO SHEET G-106 FOR FINISH W1EXISTING SOFFIT, PAINT TO MATCH CEILINGSUSPENDED CEILING SYSTEMB371-NIE-A70391-NIE-A70381-NIE-A70361-NIE-A70341-NIE-A70351-NIE-A703TYPTYP13' - 7 3/4"1' - 0"LEVEL 213' - 6"1' - 0"3' - 0"3' - 0"1' - 0"2' - 0"10' - 0"11"6"3' - 6"4' - 2"PLASTIC LAMINATE PANEL SYSTEM. REFER TO SPECIFICATIONS51-NIE-A70381-NIE-A70361-NIE-A70341-NIE-A70371-NIE-A703TYPTYPEXISTING COLUMN91-NIE-A703EXISTING SOFFITNEW ALUMINUM STOREFRONT INFILLTO MATCH EXISTING STOREFRONTELEVATOR CALL BUTTON. COORDINATE WITH ELEVATOR MFG.UP/DOWN INDICATOR"IN CASE OF FIRE USE STAIRS" SIGNFLOOR LINE0"LEVEL 213' - 6"1' - 3"1' - 4"1' - 0"3' - 0"3' - 0"1' - 0"2' - 9"2' - 9"1' - 0"2' - 6"1' - 0"2' - 6"1' - 0"1' - 4"3' - 6"3' - 7"1' - 5"EXISTING ESCALATORSTAINLESS STEEL ELEVATOR DOORBRUSHED STAINLESS STEEL BASE, LAMINATED PANEL SYSTEM, REFER TO SHEET G-106 FOR FINISH W1B3EXISTING SOFFIT, PAINT TO MATCH CEILING41-NIE-A70341-NIE-A70351-NIE-A703SUSPENDED CEILING SYSTEM61-NIE-A70391-NIE-A70381-NIE-A70371-NIE-A703TYPTYPELEVATOR CALL BUTTON. COORDINATE WITH ELEVATOR MFG.24' - 1"UP/DOWN INDICATOR"IN CASE OF FIRE USE STAIRS" SIGNSMOKE DETECTOR REFER TO MEPFLOOR LINE0"LEVEL 213' - 6"13' - 8"10' - 0"1"1' - 7"5' - 8"2' - 10"3' - 6 1/4"51-NIE-A70341-NIE-A70361-NIE-A70391-NIE-A70371-NIE-A703LAMINATED PANEL SYSTEM, REFER TO SHEET G-106 FOR FINISH EXISTING SOFFIT, PAINT TO MATCH CEILINGSUSPENDED CEILING SYSTEMEXISTING COLUMN, PAINT1' - 0"3' - 0"3' - 0"1' - 0"2' - 7"1' - 0"TOP OF ESCALATOR RAILPLASTIC LAMINATE WOOD VENEER TO MATCH MARLITE WALL. EXTEND FROM ESCALATOR BOTTOM EDGE TO MARLITE SYSTEM ABOVE. RETURN MARLITE TO VENEER.PLASTIC LAMINATE PANEL SYSTEM. REFER TO SPECIFICATIONS61-NIE-A70371-NIE-A70351-NIE-A70381-NIE-A70341-NIE-A703EXISTING COLUMNSTAINLESS STEEL ELEVATOR JAMBPLASTIC LAMINATE PANEL SYSTEM, RETURN TO ALIGN WITH ELEVATOR JAMB2' - 0"1' - 0"6' - 0"1' - 0"10' - 0"4' - 7"LEVEL 213' - 6"PLASTIC LAMINATE PANEL SYSTEM. REFER TO SPECIFICATIONSSTAINLESS STEEL ELEVATOR JAMBPLASTIC LAMINATE PANEL SYSTEM, RETURN TO ALIGN WITH ELEVATOR JAMB71-NIE-A70361-NIE-A70381-NIE-A70351-NIE-A70341-NIE-A7035' - 1"2' - 0"1' - 0"3' - 0"3' - 0"1' - 0"10' - 0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/2" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:56:42 PM1-NIE-A702PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINTERIOR ELEVATIONS - NEW INTERIORELEVATOR07-14-2017S12014 1/2" = 1'-0"1EAST ELEVATION - NEW INTERIOR ELEVATOR 1/2" = 1'-0"4NORTH ELEVATION - NEW INTERIOR ELEVATOR 1/2" = 1'-0"2SOUTH ELEVATION - NEW INTERIOR ELEVATOR 1/2" = 1'-0"3WEST ELEVATION NEW INTERIOR ELEVATOR 1/2" = 1'-0"5EAST ELEVATION - ENTRY VESTIBULE 1/2" = 1'-0"6WEST ELEVATION ENTRY - ENTRY VESTIBULEREVISIONS# DATE DESCRIPTION BYCONFORMED SET114
FLOOR LINE0"126"6' - 6"7' - 9"9"MAIN CAR OPERATING PANELW/ MFGVERIFY2' - 0 1/8"3' - 6"BRUSHED STAINLESS STEEL TOE KICKBRUSHED STAINLESS STEEL PANELBRUSHED STAINLESS STEEL HEAD PANELBRUSHED STAINLESS STEEL ELEVATOR DOORFLOOR LINE0"7' - 9"6"1' - 9"9"2' - 0"2' - 0"9"BRUSHED STAINLESS STEEL TOE KICKPLASTIC LAMINATE VENEER TO MATCH ELEVATOR EXTERIORBRUSHED STAINLESS STEEL PANELMOZ WAVES CLEARBRUSHED STAINLESS STEEL HEAD PANELEQEQPLASTIC LAMINATE VENEER TO MATCH ELEVATOR EXTERIORFLOOR LINE0"6"1' - 9"9"2' - 0"2' - 0"9"EQEQEQEQBRUSHED STAINLESS STEEL TOE KICKPLASTIC LAMINATE VENEER TO MATCH ELEVATOR EXTERIORBRUSHED STAINLESS STEEL FLAT RAILBRUSHED STAINLESS STEEL PANELMOZ WAVES CLEARBRUSHED STAINLESS STEEL HEAD PANELPLASTIC LAMINATE VENEER TO MATCH ELEVATOR EXTERIOR7' - 9"SATIN ANODIZED ALUMINUM CORNER TRIMSCHEDULED PARTITIONPLASTIC LAMINATE ON 3/4" SUBSTRATESATIN ANODIZED ALUMINUM TOP EDGESCHEDULED PARTITIONPLASTIC LAMINATE ON 3/4" SUBSTRATEPANEL CLIP1/4"3/16"NARROW MAIN RAILSCHEDULED PARTITIONPLASTIC LAMINATE ON 3/4" SUBSTRATEPANEL CLIPSATIN ANODIZED ALUMINUM BOTTOM EDGESCHEDULED PARTITIONPLASTIC LAMINATE ON 3/4" SUBSTRATEPANEL CLIPSATIN ANODIZED ALUMINUM EDGE TRIMSCHEDULED PARTITIONPLASTIC LAMINATE ON 3/4" SUBSTRATE3/16"3/4"NARROW CROSS SPLINESCHEDULED PARTITIONPLASTIC LAMINATE ON 3/4" SUBSTRATE1/4"SATIN ANODIZED ALUMINUM EDGE TRIMSCHEDULED PARTITIONPLASTIC LAMINATE ON 3/4" SUBSTRATE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:56:58 PM1-NIE-A703PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINTERIOR ELEVATIONS AND FINISH DETAILS - NEWINTERIOR ELEVATOR07-14-2017S12014 1/2" = 1'-0"1ELEVATOR INTERIOR SOUTH ELEVATION 1/2" = 1'-0"2ELEVATOR INTERIOR WEST ELEVATION 1/2" = 1'-0"3ELEVATOR INTERIOR EAST ELEVATION 12" = 1'-0"4OUTSIDE CORNER TRIM 12" = 1'-0"5TOP EDGE TRIM 12" = 1'-0"6HORIZONTAL REVEAL 12" = 1'-0"7BOTTOM EDGE TRIM 12" = 1'-0"8VERTICAL EDGE TRIM 12" = 1'-0"9VERTICAL REVEALREVISIONS# DATE DESCRIPTION BY 12" = 1'-0"10INSIDE CORNER DETAILCONFORMED SET115
UP5' - 9"9' - 7"NEW EXTERIOR ELEVATOR ENCLOSUREAREA UNDER NEW BRIDGE ABOVEEXISTING STAIRS RELOCATED 10'-0" TO THE EAST V.I.F.EXISTING STAIR LANDING RELOCATED11-NEE-A30111-NEE-A3021-NEE-A2011-NEE-A201231-NEE-A2011HOLD8' - 1 3/4"15' - 4"6' - 6"HOLD10' - 3"ELEVATOR ROOMB1-171B1BNEW LOADING DOCK ELEVATORB1-161B15' - 4"11' - 8"3' - 8"NEW CONCRETE SLABNEW COLUMN FOUNDATION - REFER TO STRUCTURALSLOPESLOPE1E1E1E1EB1-17AB1-17B3A11-NEE-A30111-NEE-A302779' - 7"21' - 10"2' - 10"6' - 0"2' - 5"DNDN1B1B1BMODIFY EXISTING GUARDRAILNEW STANDING SEAM BY "MBCI MODEL - ULTRA DEK" METAL ROOF - BELOWPRE-FINISHED ALUMINUM GUTTER & DOWNSPOUTNEW LANDINGREFER TO STRUCTURAL NEW STEEL COLUMNREFER TO STRUCT.SLOPE1/4 : 12B2-20ITB2-203A3A6' - 8"7' - 0"2"MATCH EXISTING HEIGHTCARD READER7' - 2"2"3' - 0"2"3' - 4"SINGLE FLUSH HOLLOW METAL5/8" GYPSUM BOARD BOTH SIDES3 5/8" METAL STUDS PER WALL TYPEHOLLOW METAL DOOR BATT INSULATION REFERTO WALL TYPESHOLLOW METAL FRAME7'-0" A.F.F.5/8" GYPSUMBOARD BOTHSIDESDOUBLE 3 5/8"METAL STUDS PER WALL TYPEHOLLOW METALFRAMEHOLLOW METAL DOOR BATT INSULATION REFERTO WALL TYPES5/8" 3 COAT MEDIUM SAND FINISH STUCCOHOLLOW METAL DOORAND 2" FRAMECONCRETE GROUT WITH VERTICAL REINFORCEMENT5/8" GYPSUM BOARD OVER 1 1/2" RIGID INSULATIONSEALANT, BOTH SIDESMASONRY ANCHORSEALANT, BOTH SIDESHOLLOW METAL DOOR1 1/2" RIGID INSULATION5/8" GYPSUM BOARDLINTEL WITH HORIZONTAL REINFORCEMENT5/8" 3 COAT MEDIUM SAND FINISH STUCCO2X4 WOOD BLOCKING4" HOLLOW METAL FRAME7'-4" A.F.F.DOORHOLLOW METAL DOORFRAMEFLOOR FINISH PER SCHEDULEMETAL THRESHOLD SET IN FULLBET OF MASTIC500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/15/2017 10:03:29 AM1-NEE-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAENLARGED FLOOR PLAN, DOOR SCHEDULE ANDDOOR DETAILS - NEW EXTERIOR ELEVATOR07-14-2017S12014 1/4" = 1'-0"1ENLARGED FLOOR PLAN - NEW ELEVATOR - FIRST FLOORNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDLOADING DOCK ELEVATOR 1/4" = 1'-0"2ENLARGED FLOOR PLAN - NEW ELEVATOR 2ND FLOORNNORTHDOOR SCHEDULE - EXISTING TRMINAL BSAA #CARDREADERDoor # Room NameDoor SizeDoorLabelDetailsFrameHardwareSetCommentsWidth Height Thickness Door Material Door FinishHead Jamb Threshold Material FinishB2-20 IT3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT3/1-NEE-A101 4/1-NEE-A101HOLLOW METAL PAINT 6DOOR SCHEDULE - FREIGHT ELEVATORSAA #CARDREADERDoor # Room NameDoor SizeDoorLabelDetailsFrameHardwareSetCommentsWidth Height Thickness Door Material Door FinishHead Jamb Threshold Material FinishNO B1-17A ELEVATOR EQUIP.ROOM3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT 5/1-NEE-A101 6/1-NEE-A101 7/NEE-A101 HOLLOW METAL PAINT 24NO B1-17B ELEVATOR EQUIP.ROOM3' - 0" 7' - 0" 1 3/4" HOLLOW METAL PAINT3/1-NEE-A101 4/1-NEE-A101HOLLOW METAL PAINT 6NO B1-31 ELEVATOR ROOM 3' - 0" 7' - 0" 1 3/4" SOLID WOODCORESTAIN AUTHORIZEDPERSONNEL ONLY3/1-NEE-A101 4/1-NEE-A101HOLLOW METAL PAINT 1 1/2" = 1'-0"8DOOR ELEVATIONS 3" = 1'-0"3INTERIOR DOOR HEAD 3" = 1'-0"4INTERIOR DOOR JAMB 3" = 1'-0"6EXTERIOR H/M DOOR JAMB 3" = 1'-0"5EXTERIOR HM DOOR HEAD 3" = 1'-0"7THRESHOLD DETAILREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44CONFORMED SET116
11-NEE-A30111-NEE-A3021-NEE-A20121-NEE-A2011EXISTING CEILING TO REMAIN NEW 7/8" THICK (3) COAT SMOOTH FINISH STUCCO CEILING -PAINTEDNEW LIGHT FIXTUREREFER TO ELECTRICAL775' - 4"2' - 6"EQEQ1B1B1B1B1B10' - 9"11' - 4"EXPOSED CEILINGEXPOSED CEILINGNEW LOADING DOCK ELEVATORB1-16ELEVATOR ROOMB1-17CEILING HEIGHT10' - 0"11-NEE-A30111-NEE-A302SLOPENEW STANDING SEAM METAL ROOF BY "MBCI MODEL - ULTRA DEK" OR ARCHITECT APPROVED EQUALEXISTING ROOFSLOPENEW PRE-FINISHED ALUMINUM GUTTERS AND DOWNSPOUTSSLOPESLOPE10' - 8 3/4"11' - 4"9' - 7"5' - 9"11' - 8 1/4"10' - 1 1/4"15' - 4"6' - 5 1/2"NEW STANDING SEAM METAL ROOF BY "MBCI MODEL ULTRA DEK" OR ARCHITECT APPROVED EQUALRELOCATED STAIRS BELOW31-NEE-A1021/4 : 121 : 121 : 122 : 123/8"EXISTING WALLLOW RAKE SUPPORT ANGLETRI-BEAD TAPE SEALERPARAPET RAKE FLASHINGEXISTING METAL PANEL(CENTERED IN SLOT)RIGID INSULATIONMETAL DECK14 GA. RAKE ANGLEFASTENERSNOPARAPET RAKE CLEATINSIDE CLOSURE1/4" GAPULTRA-DEK PANEL@ 24" O.C. (PRE-DRILL[FASTENER #15_]14-10 x __ DECK SCREWSTRUCTURAL ANGLE AS REQ'D.)STRUCTURAL ANGLE1 1/2"MIN.1/4-14 x 1 1/4 SHOULDERTEK 2 SELF-DRILLER12-14 x 1 1/4 LONG-LIFE SELF-DRILLER W/WASHER1/4-14 x 1 1/4 LONG-LIFESELF-DRILLER W/WASHERCONTINUOUS PEEL AND STICK MEMBRANE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:54:32 PM1-NEE-A102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREFLECTED CEILING PLAN, ROOF PLAN ANDDETAILS - NEW EXTERIOR ELEVATOR07-14-2017S12014 1/4" = 1'-0"1REFLECTED CEILING PLAN - NEW EXTERIOR ELEVATORORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDLOADING DOCK ELEVATORNNORTH 1/4" = 1'-0"2ENLARGED ROOF PLAN - NEW EXTERIOR ELEVATORNNORTHREVISIONS# DATE DESCRIPTION BY 3" = 1'-0"3EXISTING WALL FLASHING DETAILCONFORMED SET117
11-NEE-A301EXISTING METAL PANEL SIDING TO REMAINALUMINUM GUTTER & DOWNSPOUTPRE-FINISHED METAL FASCIA5/8" STUCCO ON 8" CMU ALUMINUM GUTTER & DOWNSPOUTULTRA DEK STANDING SEAM METAL ROOF BY "MBCI" OR APPROVED EQUAL7/8" THICK (3) COAT SMOOTH FINISH STUCCO OVER METAL FRAMING - PAINTEDALUMINUM GUTTER & DOWNSPOUT5/8" STUCCO ON 8" CMU EXISTING PARAPET32'-6"TOP OF MASONRY10'-0"TOP OF MASONRY31'-8"EXISTING 2ND FLOOR V.I.F.13'-4"BRIDGE TOP OF MASONRY28'-2"EXISTING GLAZING11' - 8"10' - 2"11' - 3"13' - 0"STUCCO RELIEF JOINT STUCCO RELIEF JOINT ULTRA DEK STANDING SEAM METAL ROOF BY "MBCI" OR APPROVED EQUALULTRA DEK STANDING SEAM METAL ROOF BY "MBCI" OR APPROVED EQUALREMOVE EXISTING METAL PANEL SIDING AND RETAIN FOR REINSTALLATION AFTER STRUCTURAL STEEL IS INSTALLED -REFER TO STRUCTURAL FOR LOCATIONREMOVE EXISTING METAL PANEL SIDING AND RETAIN FOR REINSTALLATION AFTER STRUCTURAL STEEL IS INSTALLED -REFER TO STRUCTURAL FOR LOCATION11-NEE-A302EXISTING ALUMINUM WINDOWTO REMAINEXISTING METAL PANEL SIDING TO REMAINALUMINUM GUTTER & DOWNSPOUTPRE-FINISHED METAL FASCIA5/8" STUCCO ON 8" CMU ALUMINUM GUTTER & DOWNSPOUTPRE-FINISHED METAL COPINGEXISTING METAL PANEL SIDING TO REMAIN5/8" STUCCO ON 8" CMU - PAINTED EXHAUST LOVER AND NEW LINTEL REFER TO MECH.STAIR LANDING OVERHANGCANOPY EAVE22'-0" A.F.F.SPLASH GUARDS AT ALL DOWNSPOUTS -TYPEXISTING STAIR - RELOCATEDEXISTING PARAPET32'-6"TOP OF MASONRY10'-0"11' - 3"13' - 0"STUCCO RELIEF JOINT ULTRA DEK STANDING SEAM METAL ROOF BY "MBCI" OR APPROVED EQUALMODIFY EXISTING RAILINGNEW FOUNDATIONS FOR EXISTING RELOCATED STAIRS - REFER TO STRUCTURAL DRAWINGSNEW EXHAUST LOUVER1' - 6"2' - 10"7' - 2"1' - 6"2' - 0"EXISTING INTERNAL STEEL COLUMNREMOVE EXISTING METAL SIDING AND INSTALL NEW TUBE STEEL IN WALL FOR AWNING SUPPORT -REFER TO STRUCTURAL -REINSTALL EXISTING SIDING11-NEE-A3017' - 0"PRE-FINISHED METAL COPING5/8" STUCCO ON 8" CMU - PAINTED PREFINISHED METAL WALL FLASHINGTOP OF ELEVATOR32'-11"2ND FLOOR V.I.F.13'-4"EXISTING LANDING6'-10" V.I.F.BOTTOM OF CANOPY22'-0"11' - 8"10' - 1"13' - 0"11' - 3"6' - 4"EXISTING TERMINAL WALLPREFINISHED METAL CANOPY CLOSURE STRIP8' - 6"OPENULTRA DEK STANDING SEAM METAL ROOF BY "MBCI" OR APPROVED EQUALSTUCCO RELIEF JOINTSTUCCO RELIEF JOINT2" METAL FRAMED OPENINGSTUCCO RELIEF JOINT1-NEE-A10231-NEE-A1023SIMREMOVE EXISTING METAL PANEL SIDING AND RETAIN FOR REINSTALLATION AFTER STRUCTURAL STEEL IS INSTALLED - REFER TO STRUCTURAL FOR LOCATIONFLASH AWNING TO SIDE OF WALL500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 10:16:21 AM1-NEE-A201PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAEXTERIOR ELEVATIONS - NEW EXTERIORELEVATOR07-14-2017S12014 1/4" = 1'-0"1WEST ELEVATION - NEW EXTERIOR ELEVATOR 1/4" = 1'-0"2SOUTH ELEVATION - NEW EXTERIOR ELEVATOR 1/4" = 1'-0"3EAST ELEVATION - NEW EXTERIOR ELEVATORORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBYCONFORMED SET118
11-NEE-A302GRADE0'-0"HOISTWAY BEAM - 16'-5" MINIMUM HEIGHT CLEAR FROM 2ND FLOOR LEVEL VERIFY WITH ELEVATOR SYSTEM SHOP DRAWINGS2ND FLOOR13'-4" V.I.F.TOP OF MASONRY32'-0"TOP OF MASONRY31'-4"TOP OF MASONRY29'-11"PREFINISHED ALUMINUM GUTTER AND DOWNSPOUTSPREFINISHED RAKE TRIMSTEEL BEAMSREFER TO STRUCTURALREINFORCED CONCRETE BEAM -REFER TO STRUCTURALNEW ULTRA DEK METAL ROOF BY MBCIOVER 5/8" EXTERIOR GRADE SHEATHING ONR-20 RIGID INSULATION ON METAL DECKTOP OF PIT-5'-8"METAL ROOF WALL FLASHING BY MBCIULTRA DEK METAL ROOF BY MBCIOVER PEEL AND STICK MEMBRANE OVER EXTERIOR GRADE SHEATHING ONR-20 RIGID INSULATION ON METAL DECK5/8" THICK (3) COAT SMOOTH FINISH STUCCO ON 8" 2 HOUR RATED CMUREFER TO STRUCTURAL FOR REINFORCEMENT5/8" STUCCO ON 8" CMUREFER TO STRUCTURAL REINFORCED CONCRETE BEAM -REFER TO STRUCTURALPREFINISHED ALUMINUM GUTTER AND DOWNSPOUTSSTEEL BEAM -REFER TO STRUCT.EXISTING RELOCATED STAIR STRUCTURENEW CONCRETE PADS FOR RELOCATED STAIR STRUCTUREREFER TO STRUCTURALCONCRETE FOOTINGREFER TO STRUCTURALCONCRETE FLOOR SLABREFER TO STRUCTURALWATER PROOF POURED CONCRETE - REFER TO STRUCTURAL112(2) STOP 5000 LB CAPACITY ELEVATOR BY SCHINDLER - MODEL 400AE - OR APPROVED EQUALNEW LOADING DOCK ELEVATORB1-16HVAC SUPPLY DUCT -REFER TO MECHANICALNOTE: SUMP PUMP FOR ELEVATOR SHALL BE ENCASED IN WATER PROOF CONCRETEINSTALL NEW PIT LADDER500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 3/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 10:20:27 AM1-NEE-A301PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL SECTION - NEW EXTERIOR ELEVATOR07-14-2017S12014 3/4" = 1'-0"1SECTION 1 AT NEW EXTERIOR ELEVATORORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBYCONFORMED SET119
11-NEE-A301OPENTOP OF MASONRYVARIES2ND FLOOR13'-4" V.I.F.FLOOR LINE0'-0"BOTTOM OF PIT-5'-8"PREFINISHED FLASHINGNEW ULTRA DEK METAL ROOF BY MBCI ON EXTERIOR SHEATHINGR-20 RIGID INSULATIONMETAL DECKSTEEL CHANNEL - REFER TO STRUCTURALSTEEL BEAMS -REFER TO STRUCTURALEXISTING METAL PANELTO REMAIN7/8" STUCCO CEILING OVER METAL LATH OVER TYVEK MEMBRANE OVER 5/8" EXTERIOR SHEATHING ON SUSPENDED METAL FRAMINGNEW LIGHT FIXTUREREFER TO ELECTRICAL5/8" STUCCO ON 8" 2 HOUR RATED CMUEXISTING DOOR & FRAME TO REMAIN5/8" STUCCO ON 8" 2 HOUR RATED CMUHOIST BEAM REFER TO STRUCT.ELEVATOR DOORS AND FRAMEBY ELEVATOR INSTALLERPREFINISHED RAKE TRIMEXISTING METAL PANELTO REMAINELEVATOR DOORS AND FRAMEBY ELEVATOR INSTALLERNEW CONCRETE FLOOR SLABREFER TO STRUCTURAL - SLOPE AWAY FROM ELEVATOR DOORWATER PROOF POURED CONCRETE ELEVATOR PIT -REFER TO STRUCTURALPREFINISHED FLASHINGPREFINISHED RAKE TRIMNEW ULTRA DEK METAL ROOF BY MBCI ON EXTERIOR SHEATHINGMECHANICAL VENT & DUCTREFER TO MECHANICALCHANNEL LOCK SIDING1-NEE-A10231-NEE-A1023OPPSIMPRE-FINISHED METAL TRIM CLOSURE PIECE2" METAL FRAMED OPENING -BOTH SIDES(2) STOP 5000 LB CAPACITY ELEVATOR BY SCHINDLER - MODEL 400AE - OR APPROVED EQUALINSTALL NEW PIT LADDER REINFORCED CONCRETE BEAM -REFER TO STRUCTURAL DRAWINGSSTEEL BEAMS - REFER TO STRUCTURAL - PAINT ALL EXPOSED STRUCTURE AND PROTECT WITH BIRD NETTINGNEW STEEL TUBE -REFER TO STRUCTURAL500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 3/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 10:20:33 AM1-NEE-A302PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL SECTION - NEW EXTERIOR ELEVATOR07-14-2017S12014 3/4" = 1'-0"1WALL SECTION 2 AT NEW EXTERIOR ELEVATORORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANEXISTING LOADING DOCKOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBYCONFORMED SET120
TableTableTableTableTableTableTableshreddercopierprinterhp 8550TableDEMOLITION PLAN LEGENDITEMS TO DEMOLISHITEMS TO REMAINDEMOLISH EXISTING ROOF DOWN TO EXISTING METAL DECK AND PREP FOR NEW TPO MEMBRANE -PHASE 2 WORK REFER TO SHEET 2-OB-A107DEMOLISH ALL EXISTING SPLIT SYSTEM CONDENSERS AND RACKS FROM THIS AREADEMOLISH EXISTING RTU'S AND DUCT WORKEXISTING MECHANICAL ROOM TO REMAINDEMOLISH EXISTING STAIRS AND LAND PLATFORMDEMOLISH ALL EXISTING PORTION OF WALL FOR NEW SCREENING EXPANSIONREMOVE AND STORE ALL EXISTING SEATING IN NEW FLOORING AREA AND RETURN TO OWNER PER PHASING PLANS. SEATING TO BE REPLACED AND RECONFIGURED AFTER NEW FLOOR IS INSTALLED.DEMOLISH EXISTING "AIRPORTS WORLDWIDE" OFFICE COMPLEXDEMOLISH EXISTING RESTROOMSREMOVE EXISTING SCREENING DEVICESDEMOLISH EXISTING OVERHEAD ROLL UP DOORS AND OPENINGS, BULKHEAD AND COLUMN WRAPS TO REMAINDEMOLISH EXISTING WALLDEMOLISH PORTION OF EXISTING CANOPYREMOVE EXISTING WINDOWS ON 2ND FLOOR OF EXISTING BUILDING. FOR EXTENT REFER TO SCREENING EXPANSION DRAWINGDEMOLISH EXISTING PORTION OF WALL TO ALLOW WALK DOOR - PHASE 1 WORKEXISTING TSA "IT" SERVER RACK TO REMAINV.I.F.26' - 10"USE SELECTIVE DEMOLITION ON CEILINGS PER HVAC AND FIRE SPRINKLER WORKDEMO EXISTING WALL FOR NEW ELEVATORCORRIDOR SHALL REMAIN SECURE DURING ALL DEMOLITION OPERATIONSDEMOLISH WALL SECTION2-OB-A2053REFER TO ELEVATION FOR EXTENT OF DEMOLITION IN WALL500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 10:23:16 AM1-SA-A100PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADEMOLITION PLAN - SCREENING AREA AND SAAOFFICES07-14-2017S12014NNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANF.I.S. CUSTOMSTERMINAL BTERMINAL A 1/16" = 1'-0"1DEMOLITION PLAN - SCREENING AREA AND SAA OFFICESREVISIONS# DATEDESCRIPTIONBYCONFORMED SET121
Table
Table
Table
Table
Table Table
Table Table DEMOLISH EXISTING OVERHEAD ROLL UP DOORS AND OPENINGS, BULKHEAD AND COLUMN WRAPS TO REMAIN2"EXISTING FOOD VENDING TO REMAINEXISTING VINYL FLOOR TO REMAIN,CLEAN FLOOR TO LIKE NEW CONDITIONREMOVE CARPET THROUGHOUT, REMOVE ALL DEBRIS/ADHESIVE FROM FLOOR AND PREP TO RECEIVE NEW FINISHREMOVE AND STORE ALL EXISTING SEATING IN NEW FLOORING AREA AND RETURN TO OWNER PER PHASING PLANS. SEATING TO BE REPLACED AND RECONFIGURED AFTER NEW FLOOR IS INSTALLED.REMOVE EXISTING TILE THROUGHOUT MAIN CORRIDOR TO FACE OF EXISTING RESTAURANT TILE FLOORING OR FACE OF EXISTING VENDOR/RESTAURANT COUNTER WALL. PREP FLOOR AND LEVEL AS NECESSARY TO RECEIVE NEW FLOORING500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/16" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:57:41 PM1-SA-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADEMOLITION PLAN - EXISTING TERMINAL B 2NDFLOOR07-14-2017S12014 1/16" = 1'-0"1DEMOLITION PLAN - TERMINAL B 2ND FLOORORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANF.I.S. CUSTOMSTERMINAL BTERMINAL ANNORTHREVISIONS# DATE DESCRIPTION BYCONFORMED SET122
EXISTING KITCHEN EXHAUST FAN TO MODIFIEDREMOVE EXISTING CEILING AND LIGHTING FROM THIS AREAREMOVE EXISTING LIGHTINGEXISTING MECHANICAL ROOM LIGHTING TO REMAINEXISTING PORTION OF CANOPY TO BE REMOVEDDEMOLISH EXISTING OVERHEAD ROLL UP DOORS AND OPENINGS, BULKHEAD AND COLUMN WRAPS TO REMAINLIGHTING IN SECURED AREA TO REMAINLIGHTING IN SECURED AREA TO REMAINREMOVE PORTION OF CEILING FOR NEW ELEVATOR CONSTRUCTION IN PHASE 1DEMOLITION REFLECTED CEILING PLAN LEGENDDEMOLISH EXISTING CEILING AND LIGHTINGDEMOLISH / REMOVEITEM TO REMAINREMOVE EXISTING CEILING AND LIGHTING FROM THIS AREALIGHTING IN SECURED AREA TO REMAINEXISTING LIGHTING AND CEILING AREA TO REMAIN500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/4/2017 11:10:54 AM1-SA-A102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADEMOLITION REFLECTED CEILING PLAN -SCREENING AREA07-14-2017S12014 1/16" = 1'-0"1DEMOLITION REFLECTED CEILING PLAN - SCREENING AREANNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANF.I.S. CUSTOMSTERMINAL BTERMINAL A 1/16" = 1'-0"2DEMOLITION REFLECTED CEILING PLAN - SCREENING AREA CONTINUEDREVISIONS# DATEDESCRIPTIONBY123 CONFORMED SET
29'-8"29'-1"28'-5"2'5'-10"12'-4"11'-2"12'-4"11'-10"12'-4"12'-5"12'-4"5'-3"10'1'-6"10'-10"3'-8"2'-7"2'4'-1"4'-8"5'-7"4'3'-5"8'-8" 8'-1" 7'-6"1'-6"1'-6"6"12'-9"5'3'1'-6"6'10'-3"9'-7"TDC #8TDC #7TDC #6TDC #5TDC #4TDC #3TDC #2TDC #1BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONTL3ENTEREXITTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATAVSAVSFRONTETDBLS
AVSAVSFRONTETDBLS
FRON
TETDBLSAVSFRONTETDBLSAVSAVSAVSFRONTETDBLS 23'-9"3'LADA GATEWTMDCEIA12ETDETDETDETD
LL43L43L3L323'-9"3'LADA GATEWTMDCEIA1 23'-9"3'LADA GATEWTMDCEIA123'-9"3'LADA GATEWTMDCEIA1EXISTING CANOPY ROOFEMERGENCY EXITEXISTING MECHANICAL ROOMB2-01NEW CANOPY ROOFSECURITY EXITB2-02SECURITY CHECKPOINT SCREENINGB2-12SECURITY OFFICEB2-08RECEPTIONB2-10OPPS MANAGER OFFICEB2-11PSRB2-15PASSENGER WAITING AREAB2-13SAA ITB2-09WOMENS ROOMB2-04TSA IT CABINETB2-07MENS ROOMB2-05EXPANDED SCREENING AREAB2-14CORRIDORB2-18PENTHOUSEB2-16JANITORB2-06CONFERENCE ROOMFP2-03OFFICEFP2-02OFFICEFP2-04OFFICEFP2-05ELECTRICALFP2-13CORRIDORFP2-01RoomFP2-17OFFICEFP2-18OFFICEFP2-07OFFICEFP2-08.OFFICEFP2-09CONFERENCE ROOMFP2-06CORRIDORFP2-01RECEPTIONFP2-10BREAK ROOMFP2-15ENTRANCEENTRANCECROSSWALK SHELTERBAGGAGE CLAIM ROOFB2-17FEFEFEFEFEFEFEFEEXTERIOR EXTERIOR NEW ELEVATORNEW ELEVATOREXTERIOR EXISTING SAA OFFICES PATH SA1PATH SA1PATH SA2PATH SA3PATH SA2PATH SA3PATH SA4PATH SA5PATH SA6PATH SA5LOST AND FOUNDB2-11BOPPS DIRECTOR OFFICEB2-11ANOTE:A MAXIMUM OF 49 PEOPLE WILL BE ALLOWED IN OFFICE AREA DURING CONSTRUCTION BECAUSE ONLY ONE EXIT WILL BE AVAILABLE. G.C. TO POST SIGN ON ENTRY DOORS OF OFFICE AREAMAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT (1004.1.2)LEGENDAIRPORT TERMINAL / CONCOURSE 100 GROSSAIRPORT TERMINAL / WAITING AREAS 15 GROSSAIRPORT TERMINAL / MERCANTILE 30 GROSSAIRPORT TERMINAL / BUSINESS 100 GROSSAIRPORT TERMINAL / STANDING 5 GROSSLIFE SAFETY LEGENDFEWALL MOUNTED FIRE EXTINGUISHER / 10LB TYPE ABCEMERGENCY LIGHT (EM)EXIT SIGNSTOTAL EXIT WIDTH REQUIRED (1005.1) TOTAL OCCUPANT LOAD x 0.2 INCHES PER PERSON = INCHES REQUIRED2956 PEOPLE x 0.2 INCHES PER PERSON = 591.2 INCHES REQUIREDEXIT WIDTH PROVIDED2 - 120" DOORS 240 INCHES CLEAR WIDTH4 - 96" EXIT DOORS:348 INCHES CLEAR WIDTH 4 - 36" EXIT DOORS72 INCHES CLEAR WIDTHTOTAL PROVIDED 660 INCHES CLEAR WIDTH PROVIDED OCCUPANCY CALCULATIONS - SCREENING AREASPACE / USE OCCUPANCY AREA OCCUPANT PER S.F. OCCUPANT LOAD WAITINGAPT - W14,245 S.F.1/52849BUSINESSB10,621 S.F.1/100107 TOTAL 24,866 S.F.TOTAL OCCUPANTS 2956 PEOPLEFIRE PROTECTION SERVICES (FBC 906.3(1)FIRE ALARM SYSTEM AND PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AT A MAXIMUM TRAVEL DISTANCE OF 75'. MAXIMUM FLOOR AREA FOR EACH EXTINGUISHER IS 11,250 SF MEANS OF EGRESS (FBC 1004.1.2)MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANTAIRPORT TERMINAL WAITING AREAS15 SF GROSS PER OCCUPANTBUSINESS100 SF GROSS PER OCCUPANTCOMMON PATH OF EGRESS TRAVEL (1014.3)BUSINESS / WAITING (SPRINKLED)100 FEET MAXIMUM EXIT ACCESS TRAVEL DISTANCE (1016.2)BUSINESS / WAITING (SPRINKLED)300 FEET RE: SHEET GS109 FOR ADDITIONAL INFORMATIONCODE INFORMATION - SCREENING AREA500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:58:37 PM1-SA-A103PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDALIFE SAFETY PLAN - SCREENING AREA07-14-2017S12014 1/16" = 1'-0"1LIFE SAFETY PLAN - SCREENING AREANNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDEGRESS DATA SCREENING AREAEXIT ROUTE DISTANCEPATH SA1 120' - 0"PATH SA2 144' - 9"PATH SA3 232' - 5"PATH SA4 179' - 5"PATH SA5 205' - 4"PATH SA6 65' - 1"REVISIONS# DATE DESCRIPTION BYCONFORMED SET124
29'-8"29'-1"28'-5"2'5'-10"12'-4"11'-2"12'-4"11'-10"12'-4"12'-5"12'-4"5'-3"10'1'-6"10'-10"3'-8"2'-7"2'4'-1"4'-8"5'-7"4'3'-5"8'-8" 8'-1" 7'-6"1'-6"1'-6"6"12'-9"5'3'1'-6"6'10'-3"9'-7"TDC #8TDC #7TDC #6TDC #5TDC #4TDC #3TDC #2TDC #1BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONTL3ENTEREXITTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATAVSAVSFRONTETDBLS
AVSAVSFRON
TETDBLS
FRONTETDBLSAVSFRONTETDBLSAVSAVSAVSFRONTETDBLS 23'-9"3'LADA GATEWTMDCEIA12ETDETDETDETD
LL4
3L43L3L323'-9"3'LADA GATEWTMDCEIA123'-9"3'LADA GATEWTMDCEIA123'-9"3'LADA GATEWTMDCEIA1EXISTING CANOPY ROOF - MODIFIEDPLENUMEMERGENCY EXIT STAIRSMACHINELESS ROOM ELEVATOREXISTING MECHANICAL ROOMB2-01SECURITY EXITB2-02SECURITY CHECKPOINT SCREENINGB2-12SECURITY OFFICEB2-08RECEPTIONB2-10OPPS MANAGER OFFICEB2-11PSRB2-15PASSENGER WAITING AREAB2-13SAA ITB2-09WOMENS ROOMB2-04TSA IT CABINETB2-07MENS ROOMB2-05EXPANDED SCREENING AREAB2-14CORRIDORB2-18PENTHOUSEB2-16JANITORB2-0621-SA-A3011-SA-A20111-SA-A4021CONFERENCE ROOMFP2-03OFFICEFP2-02OFFICEFP2-04OFFICEFP2-05CORRIDORFP2-01ELECTRICALFP2-13RESTROOMFP2-14RECEPTIONFP2-10CORRIDORFP2-01RoomFP2-17OFFICEFP2-18BREAK ROOMFP2-15OFFICEFP2-21OFFICEFP2-19CONFERENCE ROOMFP2-06OFFICEFP2-09OFFICEFP2-08.OFFICEFP2-071-SA-A401121-SA-A30211-SA-A302333332333333B333552B2B2B2B12CORRIDORB2-03TEMPORARY WALLNEW ROOF ACCESS MAN DOOR AND STAIR1-SA-A40313333LOST AND FOUNDB2-11BOPPS DIRECTOR OFFICEB2-11AEGRESS CORRIDORB2-19B2-19B2-19A2B335Generic - 6"555555Generic - 6"1-SA-A71222-OB-A20532-OB-A20522-OB-A205111-SA-A50122Generic - 6"Generic - 6"NEW ROOF ACCESS LADDERROOF REPLACEMENT - PHASE 2NEW CANOPY - PHASE 2NEW CANOPY - PHASE 2NEW ALUMINUM ROOF RACK -ATTACH TO EXISTING METAL ROOF DECKV.I.F.15' - 4"REFER TO ELEVATION FOR SCOPE OF WORKPATCH EXISTING ROOF FORM DEMOLITION OF EXISTING RTU'SWALL TYPE LEGENDNEW STUD WALLEXISTING WALLSCREENING AREA KEYNOTES#1NEW ONE WAY EXIT CORRIDOR BY "EXIT CENTURY" OR APPROVED EQUAL27" SINGLE STEP3ADD NEW ALUMINUM PANELS - MATCH EXISTING FINISH AND PANEL STYLE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/5/2017 8:33:03 AM1-SA-A104PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFLOOR PLAN - SCREENING AREA07-14-2017S12014 1/16" = 1'-0"1FLOOR PLAN - SCREENING AREANNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDEXISTING SAA OFFICES1ST FLOOR TICKETINGEXISTING AREA TO REMAIN -NEW CEILING LIGHTING - REFER TO ELECTRICAL DRAWINGSREVISIONS# DATEDESCRIPTIONBY125CONFORMED SET
SECURITY CHECKPOINT SCREENINGB2-12EXPANDED SCREENING AREAB2-14OPPS MANAGER OFFICEB2-11RECEPTIONB2-10SAA ITB2-09SECURITY OFFICEB2-08TSA IT CABINETB2-07WOMENS ROOMB2-04MENS ROOMB2-05PSRB2-15PASSENGER WAITING AREAB2-13CORRIDORB2-18SECURITY EXITB2-02EXISTING MECHANICAL ROOMB2-01ELEVATOR 3B1-48ELEVATOR 4B1-49EXISTING TICKETINGB1-1021-SA-A30211-SA-A302NEW LIGHTING REFER TO ELECTRICAL11-SA-A303CEILING HEIGHT11' - 0"CEILING HEIGHTEXISTINGNEW CEILING HEADER @ 9'-6" A.F.F.CEILING HEIGHT10' - 0"CH=10'-0"CH=10'-0"CH=10'-0"CH=9'-0"CH=9'-0"CH=9'-0"CH=9'-0"CH=9'-0"CH=9'-0"PATCH AND REPAIR EXISTING BULKHEAD WHERE ROLL UP DOOR HAVE BEEN REMOVED61-SA-A403SIM61-SA-A403NEW CEILING HEADER @ 9'-6" A.F.F.SOFFIT HEIGHT8' - 0"REFLECTED CEILING PLAN LEGEND2 X 4 LED LIGHTING FIXTURECEILING SUPPLY DIFFUSER SEE MECHANICAL DWGS.GYP. BOARD CEILING ACCESSEXIT SIGN, ARROW INDICATES EXIT DIRECTION SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATIONINDICATES FINISHED GYP. BOARD CEILING OR SOFFITEMERGENCY LIGHTS RE: ELECTRICAL DRAWINGS2 X 2 LAY-IN ACOUSTICAL TILE IN T-BAR GRID. 1. FIXTURES, CONDUITS, DUCTWORK, PIPING, ETC. SHALL BE INSTALLED AS HIGH AS POSSIBLE.2. ADDITIONAL DIRECTIONAL EXIT SIGNS MAY BE REQUIRED. CONTRACTOR TO VERIFY QUANTITIES AND COORDINATE LOCATIONS IN THE FIELD WITH THE FIRE DEPARTMENT FIRE INSPECTOR.3. EMERGENCY LIGHTING SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE.4. MECHANICAL DIFFUSERS TO MATCH ADJACENT CEILING TILE.5. SEE ELECTRICAL DRAWINGS FOR ALL LIGHT FIXTURES 6. INSTALL NEW SPEAKERS AT EXISTING SPEAKER LOCATIONS IN NEW WORK AREA -TYPICALREFLECTED CEILING GENERAL NOTESRECESSED LED CAN LIGHTINGSURFACE MOUNTED EXTERIOR WALL PACKFIRE SPRINKLER HEADPREFINISHED METAL SOFFIT PANELPREFINISHED HANGING PERFORATED METAL PANELCEILING RETURN DIFFUSER SEE MECHANICAL DWGS.INTERIOR WALL HEIGHT LEGENDFULL HEIGHT WALL ATTACHED TO DECKWALL TO EXTEND TO 6" ABOVE FINISHED CEILING - BRACE TO STRUCTURE ABOVENEW CEILING TILE AND GRIDCEILING HEIGHT10' - 0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/5/2017 8:47:42 AM1-SA-A105PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREFLECTED CEILING PLAN - SCREENING AREA07-14-2017S12014 1/16" = 1'-0"1REFLECTED CEILING PLAN - SCREENING AREANNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUND 1/16" = 1'-0"2REFLECTED CEILING PLAN - SCREENING AREA CONTINUEDNNORTHREVISIONS# DATEDESCRIPTIONBY126CONFORMED SET
1/4-14 x 1 1/4 LONG-LIFESELF-DRILLER W/WASHER[FASTENER #1E]1/4-14 x 1 1/4 SHOULDERTEK 2 SELF-DRILLER[FASTENER #5]1/4-14 x 1 1/4 LONG-LIFESELF-DRILLER W/WASHER[FASTENER #1E]NOTE:REFERENCE TYPICAL TRIMLAP SECTIONSDIM.3/8"EXISTING ROOF PANELTRI-BEAD TAPE SEALER@ 24" O.C.@ 24" O.C.(CENTERED IN SLOT)METAL DECKRIGID INSULATION@ 24" O.C.SLIP JOINT TRIMPARAPET RAKE CLEAT [F292]TRI-BEAD TAPE SEALERULTRA-DEK PANELLOW RAKE SUPPORT ANGLE2 x 4 x 16 GA. ANGLE@ 24" O.C.SCREW [FASTENER #15_]14-10 x __ DECK(MIN. 3/4" PENETRATIONINTO METAL DECK)(6" MAX.)NO FASTENERSNEW ROOF OVER SKYWALKEXISTING ROOFING TO REMAINNEW STANDING SEAM METAL ROOF BY "MBCI MODEL ULTRA DEK" OR ARCHITECT APPROVED EQUAL11-SA-A30121-SA-A301SLOPE 1/2:1221-SA-A302EXISTING GUTTER TO REMAIN 11-SA-A30311' - 8 1/2"27' - 11"29' - 3"13' - 9"23' - 10 1/2"49' - 1"60 MIL TPO MEMBRANE OVER 5/8" COVERBOARD OVER R-20 INSULATION CONTINUOUS ROOF EXPANSION JOINTUSE STRUCTURAL CANTILEVER BEAMS TO PITCH ROOF 1/4" PER FOOTNEW PREFINISHED ALUMINUM GUTTER AND DOWNSPOUT TO DISCHARGE ON EXISTING CANOPY BELOWSLOPESLOPE11-SA-A1061/4" / 12"1/4" / 12"RELOCATE EXISTING COMMUNICATIONS ANTENNA -VERIFY NEW LOCATION WITH SAANEW ROOF ACCESS LADDER11-SA-A10631-SA-A106EXISTING ROOFFLASH NEW CONNECTIONS TO GIRDERSREMOVE EXISTING METAL WALL PANEL AND WELD, BOLT OR FASTEN ROOF LADDER CONNECTIONS TO EXISTING GIRDERSRETURN NEW ROOF LADDER TO EXISTING ROOF SURFACE - SECURE TO WALL ON BOTH SIDESREMOVE EXISTING METAL WALL PANEL AND WELD ROOF LADDER CONNECTIONS TO EXISTING GIRDERS2 1/4" ALUMINUM RUNGS2 1/2" ALUMINUM SIDE RAILSALUMINUM PLATFORM AT PARAPET3' - 6"EXTERIORINTERIORSECURITY CHECKPOINT SCREENINGB2-12BAGGAGE CLAIM ROOFB2-17EXISTING GIRDERS - LOCATE AND VERIFY IN FIELDEXISTING GIRDERS - LOCATE AND VERIFY IN FIELDEXISTING PARAPET FLASHING TO REMAIN1' - 7"REMOVE EXISTING METAL WALL PANEL AND WELD, BOLT OR FASTEN ROOF LADDER CONNECTIONS TO EXISTING GIRDERS500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/5/2017 9:41:31 AM1-SA-A106PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAROOF PLAN - SCREENING AREA07-14-2017S12014 1/8" = 1'-0"2ROOF PLAN - SCREENING AREANNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUND 3" = 1'-0"1ROOF EXPANSION JOINTREVISIONS# DATEDESCRIPTIONBY 3/4" = 1'-0"3SECTION @ ROOF LADDER127CONFORFMED SET
21-SA-A30121-BC3-A10114' - 0"4' - 0"14' - 0"4' - 0"FLOOR LINENEW STOREFRONT WINDOWSNEW STOREFRONT WINDOWS - KAWNEER IR501T WITH INSULATED GLAZING OR APPROVED EQUALNEW PREFINISHED STEEL SIDING -MATCH ADJACENT FINISH AND COLORNEW PREFINISHED ALUMINUM COPING CAPNEW PREFINISHED ALUMINUM FLASHINGNEW EXHAUST FAN21-SA-A30211-SA-A302NEW PREFINISHED STEEL SIDING -MATCH ADJACENT FINISH AND COLORNEW PRE FABRICATED ALUMINUM STAIR SYSTEM - REFER THE STRUCTURALSCREENING AREA FLOOR LINE13'-6"ROOF LINE4' - 0"6' - 0"TO REMAINEXISTING STRUCTURE14' - 0"NEW PREFINISHED ALUMINUM GUTTER AND DOWNSPOUT4' - 0"6' - 0"EXISTING CANOPY STRUCTURE26' - 6"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:59:56 PM1-SA-A201PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAEXTERIOR ELEVATION - SCREENING AREA07-14-2017S12014 1/4" = 1'-0"1EAST ELEVATION - SCREENING AREAORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDEXTERIOR PERSPECTIVE VIEW - SCREENING AREAREVISIONS# DATE DESCRIPTION BYCONFORMED SET128
NEW SCREENING EXPANSION ROOFNEW ROOF OVER EXISTINGPAINT ALL STRUCTURE BELOW CONCRETE SLAB AND PROTECT WITH BIRD NETTINGEXISTING BAGGAGE CLAIM 3NEW PLENUM FOR MECHANICALNEW SCREENING CEILING21-SA-A301NEW BUILDING ADDITIONEXISTING S.A.A. OFFICES AND BAGGAGE CLAIM 3PSRB2-15EXPANDED SCREENING AREAB2-14CONFERENCE ROOMFP2-03CORRIDORFP2-01EXPANDED SCREENING AREAB2-14BAGGAGE CLAIM 3FP1-03PASSENGER WAITING AREAB2-13SCREENING EXPANSION 1ST FLOORFP1-01EGRESS CORRIDORB2-19B2-199' - 0"NEW STOREFRONT GLAZINGNEW GLAZING - REFER TO SHEET 1-SA-A603 9' - 6"9' - 0"11' - 0"6' - 0"6' - 0"6' - 0"9' - 0"8' - 0"BRACE STOREFRONT GLAZING SOFFIT TO STRUCTURE ABOVE - TYP NEW EMERGENCY EGRESS STAIRS BEYONDRoomFP2-17CORRIDORFP2-0111-SA-A301PREFINISHED METAL SIDINGEXISTING SAA EXIT DOOR - PAINT DOOR AND FRAMENEW WALL OPENINGEXISTING BAGGAGE CLAIM 2EXISTING BAGGAGE CLAIM 1EXISTING BAGGAGE CLAIM 3NEW SCREENING EXPANSION ROOFSAA OFFICES EXISTING ROOFSUSPENDED CEILING SYSTEMEXISTING ROOF 1-SA-A302111-SA-A303INFILL EXISTING WALL OPENING WITH MASONRYPATCH AND PAINT TO MATCH EXISTING ADJACENT FINISH AND COLOR NEW AIR INTAKE LOUVERPAINT EXPOSED STRUCTURE AND PROTECT WITH BIRD NETTING - TYP11' - 0"8' - 0"EXPANDED SCREENING AREAB2-14SCREENING EXPANSION 1ST FLOORFP1-01OPPS DIRECTOR OFFICEB2-11A4' - 6"10' - 0"4' - 0"3' - 0"REMOVE WINDOW.INFILL WITH METAL STUD WALL AND METAL SIDINGNEW BUILDING ADDITIONALIGNEXISTING GLAZING9' - 0"EXISTING BUILDINGBRACE STOREFRONT GLAZING SOFFIT TO STRUCTURE ABOVE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/8" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/5/2017 10:19:58 AM1-SA-A301PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDABUILDING SECTIONS - SCREENING AREA07-14-2017S12014 1/8" = 1'-0"1NORTH SOUTH BUILDING SECTION AT SCREENING EXPANSIONORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUND 1/8" = 1'-0"2EAST WEST BUILDING SECTION AT SCREENING AREAREVISIONS# DATEDESCRIPTIONBY129CONFORMED SET
B511-SA-A301NEW STEEL JOISTS;REFER TO STRUCTURALNEW 2 1/2" METAL STUDSATTACHED TO BEAM; REFER TOSTRUCTURAL FOR ATTACHMENTMBCI WALL PANELSOVER BUILDING WRAPOVER EXT. GRADE SHEATHINGOVER METAL STUDS @ 16" O.C.2'x2' LAY-IN TILE CEILING A ND GRID SYSTEM; REFER TO REFLECTED CEILING PLAN.NEW EXIT SIGNNEW DOOR AND FRAME;REFER TO DOOR SCHEDULE+ 12'-8"T/STEEL+ 13'-6"2nd FLOOR0'-0"FINISH FLOOR+ 29'-6"T/STEEL BEAM3' - 5 1/2"NEW 42" HIGH ALUMINUM GUARDRAILNEW 6" CONCRETE SLAB;REFER TO STRUCTURALNEW 10 MIL VAPOR BARRIER OVERTERMITE TREATED COMPACTED FILLFLOOR FINISH AS SCHEDULEDR-13 BATT INSULATION+ 30'-0"B/DECKEXPANDED SCREENING AREAB2-14SCREENING EXPANSION 1ST FLOORFP1-011-SA-A30241-SA-A3023PAINT ALL EXPOSED STRUCTURE AND INSTALL BIRD NETTING UNDER ENTIRE EXPOSED FLOOR - TYPNEW KAWNEER TRI FAB 451 GLAZING OR ARCHITECT APPROVED EQUAL9' - 0"BRACE SOFFIT TO STRUCTURE ABOVE @ 48" O.C.NEW 6" WIDE METAL STUD SOFFIT -EXTEND DRYWALL TO 6" ABOVE CEILING FINISHB5FLOOR FINISH AS SCHEDULED OVERNEW CONCRETE FLOOR OVERSTEEL DECKALUMINUM THRESHOLDHOLLOW METAL DOOR AND FRAME;REFER TO SCHEDULENEW STEEL BEAM; REFERTO STRUCTURALNEW STEEL JOIST; REFER TOSTRUCTURALMBCI WALL PANELS OVER BUILDING WRAP OVER EXT. GRADE SHEATHINGOVER METAL STUDS @ 16" O.C.WRAP JOIST WITH METAL PANELSMETAL STUDS ATTACHED TO JOIST WITH CLIPSNEW METAL STAIR SYSTEMCONTINUOUS METAL DRIP EDGEB511-SA-A301SCREENING EXPANSION 1ST FLOORFP1-01PAINT ALL EXPOSED STRUCTURE AND INSTALL BIRD NETTING - TYPFLOOR FINISH AS SCHEDULED OVERNEW CONCRETE SLAB OVER 10 MIL VAPOR BARRIER OVER TERMITE TREATED FILLNEW KAWNEER IR501T GLAZING OR ARCHITECT APPROVED EQUAL2'x2' LAY-IN PANEL CEILING AND GRID SYSTEM;REFER TO REFLECTED CEILING PLANMBCI WALL PANELS OVER BUILDING WRAPOVER EXT. GRADE SHEATHING OVER METAL STUDS - REFER TO STRUCTURAL FOR STUD SPACING AND GAUGEFLOOR FINISH AS SCHEDULED OVER NEWCONCRETE SLAB ON METAL DECKR-13 BATT INSULATION2 1/2" STUDS ATTACHED TO BEAMNEW KAWNEER TRI FAB 451 GLAZING OR ARCHITECT APPROVED EQUALFINISH FLOOR0'-0"T/STEEL12'-8"B/WINDOW FRAME+ 19'-6"T/WINDOW FRAME+ 23'-6"T/STEEL+ 29'-6"B/DECK+ 30'-0"2nd FLOOR+ 13'-6"1-SA-A30235/8" GYPSUM WALL BOARD1-SA-A60311-SA-A6033.04 ALUMINUM BREAK METAL SILL FLASHINGSTANDING SEAM METAL ROOFING BY(MBCI MODEL ULTRA DEK) OVERCONTINUOUS PEEL AND STICKMEMBRANE OVER 5/8" COVER BOARDOVER RIGID INSULATION R-20 OVERMETAL DECKTRI-BEAD TAPE SEALERLOW RAKE SUPPORT ANGLE12-24 X 1 1/2 PAN HEAD TEK 4.5 SELF DRILLER @ 12" O.C.PEEL AND STICK MEMBRANECONTINUOUS SCULPTURED PREFINISHED METAL RAKE TRIMRAKE SLIDE TRIMOUTSIDE CLOSURE1/4-14 X 7/8 LONG-LIFE LAPTEK W/WASHER @ 12" O.C.2 X 4 X 16 GAUGE ANGLE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/6/2017 12:55:46 PM1-SA-A302PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL SECTIONS AND DETAILS - SCREENING AREA07-14-2017S12014 3/4" = 1'-0"1SECTION AT SCREENING AREA EXPANSION 1 1/2" = 1'-0"4ENLARGED DETAIL 3/4" = 1'-0"2SECTION AT SCREENING AREA EXPANSION 2 1 1/2" = 1'-0"3RAKE DETAILREVISIONS# DATEDESCRIPTIONBY130CONFORMED SET
1-SA-A3032STANDING SEAM METAL ROOFOVER PEEL AND STICK MEMBRANE OVERCOVER BOARD OVER RIGID INSULATION ON METAL DECKEXPANDED SCREENING AREAB2-14SCREENING EXPANSION 1ST FLOORFP1-01CONFERENCE ROOMFP2-03BAGGAGE CLAIM 3FP1-035/8" GYPSUM BOARD OVERMETAL STUDS AT 16" O.C.SCHEDULED FLOOR FINISHOVER CONCRETE FLOOR OVER METAL DECK1-SA-A3033EXISTING METAL BUILDING LAY-IN CEILING TILEAND GRID SYSTEMSTEEL JOISTS;REFER TO STRUCTURALINFILL EXISTING WINDOW GLAZING WITH NEW METAL WALL PANELS OVER 6" STUD FRAMING 6"SOFFIT DEPTH3' - 0"8' - 0"3' - 0"T/JOIST+ 13'-1"3 1/2" FIBERGLASS BATT DENSGLASS SHEATHINGDRYWALL FINISHPAINTEDREMOVE EXISTING WINDOW AND SILL IN SECOND FLOOR CONFERENCE ROOM AND OFFICECONTINUOUS ALUMINUMCOPING CAPP.T. WOOD BLOCKINGCOUNTER FLASHING WITHREGLET AND 'Z' CLOSUREFLASHING FASTENERALUMINUM FLASHINGSILICONE SEALANTSTANDING SEAM ROOFUNDERLAYMENTSTANDING SEAM METAL CLIPVAPOR BARRIER OVERPLYWOOD SHEATHINGOVER RIGID SHEATHINGMETAL DECKSTEEL JOISTSMETAL BUILDING PANELOVER TYVEKOVER EXTERIOR SHEATHINGON METAL STUDS @ 16" O.C.EXISTING WALL WITH METAL STUD INFILLEXISTING ROOFEXISTING GUTTERNEW PARAPET FLASHING -REFER TO DETAIL 3 ON THIS PAGENEW "MBCI" METAL PANEL OR APPROVED EQUAL - MATCH ADJACENT STYLE AND COLORMETAL BUILDING PANELOVER TYVEK WEATHER BARRIEROVER PLYWOOD SHEATHINGON METAL STUDS @ 16" O.C.CONTINUOUS METAL ENDCAP FLASHINGCONTINUOUS METAL DECKNEW 60 MIL TPO MEMBRANE OVER COVER BOARD OVER R-20 RIGID INSULATIONNEW ROOF TRUSS - REFER TO STRUCTURALEXISTING PURLINCONTINUOUS TERMINATION BARWELDED SPLICECONTINUOUS BLOCKING FOR TERMINATION BAR ATTACHMENTSTEEL L'S PITCHED 1/4" / 1'-0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 2:00:58 PM1-SA-A303PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWALL SECTION AND DETAILS - SCREENING AREA07-14-2017S12014 3/4" = 1'-0"1SECTION AT SCREENING AND EXISTING 1 1/2" = 1'-0"2PARAPET DETAIL 1 1/2" = 1'-0"3SECTION AT SCREENING PARAPET AND EXISTING EAVEORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BYCONFORMED SET131
29'-8"29'-1"28'-5"2'5'-10"12'-4"11'-2"12'-4"11'-10"12'-4"12'-5"12'-4"5'-3"10'1'-6"10'-10"3'-8"2'-7"2'4'-1"4'-8"5'-7"4'3'-5"8'-8"8'-1"7'-6"1'-6"1'-6"6"12'-9"5'3'1'-6"6'10'-3"9'-7"TDC #8TDC #7TDC #6TDC #5TDC #4TDC #3TDC #2TDC #1BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONTL3ENTEREXITBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONTL3ENTEREXITBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONTL3ENTEREXITTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATAVSAVSFRONTETDBLSAVSAVSFRONTETDBLSFRO
N
TETDBLSAVSFRONTETDBLSAVSAVSAVSFRONTETDBLS 23'-9"3'LADA GATEWTMDCEIA12ETDETDETDETDLL43L43L3L323'-9"3'LADA GATEWTMDCEIA123'-9"3'LADA GATEWTMDCEIA123'-9"3'LADA GATEWTMDCEIA1SECURITY CHECKPOINT SCREENINGB2-12EXPANDED SCREENING AREAB2-14SECURITY CHECKPOINT SCREENINGB2-12RECEPTIONB2-10OPPS MANAGER OFFICEB2-11CORRIDORB2-18EXISTING MECHANICAL ROOMB2-01PASSENGER WAITING AREAB2-13CONFERENCE ROOMFP2-03OFFICEFP2-02CORRIDORFP2-01OFFICEFP2-04BAGGAGE CLAIM ROOFB2-17PSRB2-15BADGE READER ON EXITREMOVE WINDOWS AND SILLS.INFILL WITH METAL STUD FRAMING THAT EXTENDS TO NEAREST ADJACENT GIRDER. INSTALL INSULATION, DRYWALL, SHEATHING, AND PREFINISHED SIDING ON EXPOSED EXTERIOR3' - 7 3/4"2' - 11 1/4"3' - 3"3' - 3"2' - 4 1/4"1' - 7 3/4"7' - 11 1/2"4' - 8"5' - 7"TEMPORARY WALL55555333333OPPS DIRECTOR OFFICEB2-11ALOST AND FOUNDB2-11B2B2B2B2BAREA TO REMAIN SECURE DURING CONSTRUCTIONNEW BENCHES NEW BENCHES NEW BENCHES MODIFIED EXISTING CANOPY BELOWNEW ROOF ACCESS LADDER SEE SHEET 2-OB-A205153' - 5"42' - 2"12' - 0"45' - 0"12' - 0"42' - 3"37' - 4"123' - 7"46' - 11"22' - 9"3' - 0"8' - 1"6' - 10"5' - 8"36' - 5"8' - 1"51' - 11"4' - 6"16' - 0"13' - 4"16' - 2"SINGLE STEPPLENUM500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/8" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/5/2017 10:39:19 AM1-SA-A401PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAENLARGED FLOOR PLAN - SCREENING AREA07-14-2017S12014 1/8" = 1'-0"1ENLARGED FLOOR PLAN - SCREENING AREANNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY132CONFORMED SET
OPPS MANAGER OFFICEB2-11RECEPTIONB2-10SAA ITB2-09SECURITY OFFICEB2-08TSA IT CABINETB2-07WOMENS ROOMB2-04MENS ROOMB2-05JANITORB2-06PASSENGER WAITING AREAB2-13CORRIDORB2-031-SA-A711131-SA-A71157245a99945e45e45' - 4"7' - 0"6' - 10"5' - 4"11' - 8"7' - 0 1/2"12' - 7 1/2"5"10' - 0"5"10' - 0"5"6' - 5"5"29' - 7"5"19' - 0"5"14' - 0"5"6' - 0"5"33' - 5"5' - 5"13' - 7 1/2"5' - 5"2' - 6"5' - 0 1/2"6' - 1"6' - 8"4' - 0"13' - 5 1/2"4' - 6"8' - 11 1/2"5' - 3"6' - 7"33333332333B33333335"17' - 1"5"15' - 6"19' - 0 1/2"4 1/2"1' - 6 1/2"1211a11a8c8a142211c3' - 6 1/2"2468B2-068' - 0"(4 EQUAL STALLS)12' - 5"3' - 1"1733' - 6"3' - 6"8a8a8a8a6' - 2"7' - 11 1/2"5e7c5e447a445e7a5b11c103a5e5e182323232323232312' - 1"4 1/4"1' - 2"LOST AND FOUNDB2-11BOPPS DIRECTOR OFFICEB2-11A5"22' - 0"5"10' - 2"5"2' - 1"3B#136" GRAB BAR242" GRAB BAR3BABY CHANGING TABLEa. SOLID SURFACE BABY CHANGING TABLE WITH INTEGRAL 4" FRONT EDGEb. STAINLESS STEEL RECESSED BABY CHANGING STATIONc. SURFACE MOUNTED ADA CHANGING STATION4WALL/ FLOOR MOUNTED TOILET - FLUSH VALVE ON OPEN SIDE OF SPACE IN ALL ADA STALLS - REFER TO PLUMBING5TOILET PAPER DISPENSERa. RECESS MOUNTED JUMBO TISSUE DISPENSERb. RECESS MOUNTED JUMBO TISSUE DISPENSER WITH SANITARY NAPKIN DISPOSALc. NOT USEDd. NOT USEDe. PARTITION/WALL MOUNTED JUMBO DISPENSER7SANITARY NAPKIN DISPOSALa. SHARED PARTITION MOUNTEDb. PARTITION SURFACE MOUNTEDc. RECESSED8MIRRORa. 24" X 36" WALL MOUNTEDb. 24" X 48" WALL MOUNTEDc. 18" X 36" WALL MOUNTED9WALL MOUNTED URINAL10SOLID SURFACE COUNTER WITH 1 1/2" INTEGRAL FRONT EDGE. COUNTER MOUNTED AT 5'-0" AFF.11SINKS - REFER TO PLUMBING & ELECTRICAL DRAWINGSa. ADA SINGLE SOLID SURFACE TROUGH SINK WITH TOUCHLESS HANDWASHING CONTROLb. CONTINUOUS SOLID SURFACE TROUGH SINK AND 2 TOUCHLESS WASH BAR. c. CONTINUOUS SOLID SURFACE TROUGH SINK AND 3 TOUCHLESS WASH BAR. d. STANDARD ADA COMPLIANT WALL MOUNTED SINK WITH ADA FAUCET CONTROLSe. ADA COMPLIANT DROP IN SINK AND FAUCETRESTROOM LEGEND12ADA WALL MOUNTED SOAP DISPENSER13ADA WALL MOUNTED DRYERADA COMPLIANT SHOWER SEAT14SHOWER CURTAIN AND ROD15PLASTIC LAMINATE TALL CABINET1617MOP SINK WITH WALL MOUNTED MOP CLIPS18HI / LOW ADA DRINKING FOUNTAINS19WALL MOUNTED COAT HOOKS20ADA RESTROOM WALL SIGNAGE21WALL TILE - REFER TO SHEET G106 FOR FINISHa. FIELD TILEb. ACCENT TILEc. BULLNOSE TILEd. COVE BASE TILE 1. REFER TO SHEET G111 FOR ADA SPECIFICATIONS.2. ALL FIELD WALL TILE GROUT LINES TO ALIGN WITH FLOOR GROUT LINES. 3. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.GENERAL NOTES22TOILET PARTITION23PARTITION MOUNTED COAT HOOKXX24NAPKIN/TAMPON VENDOR6PLASTIC LAMINATE COUNTER WITH 4" BACKSPLASH ON 3 SIDES. COLOR TBD.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 11:15:29 AM1-SA-A402PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAENLARGED RESTROOM PLAN - SCREENING AREA07-14-2017S12014 1/4" = 1'-0"1ENLARGED PLAN - SCREENING AREANNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBYCONFORMED SET133
41-SA-A40310' - 2"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 5 1/2"55' - 5 1/2"3' - 1"1' - 5 1/2"6' - 2 1/2"1' - 5 1/2"3' - 1"15' - 3 1/2"1-SA-A40331-SA-A40321-SA-A4035METAL STUD FRAMED WALL WITH MARLITE PANELSAUTOMATIC DOUBLE STOREFRONT DOORAUTOMATIC DOUBLE STOREFRONT DOOR MARLITE PANEL WRAPPED COLUMN -TYPICAL MARLITE PANEL WRAPPED COLUMN -TYPICAL3B3B3B3B3B3B553SECURITY EXITB2-02CORRIDORB2-18PASSENGER WAITING AREAB2-13PASSENGER WAITING AREAB2-136' - 2 1/2"LEVEL 213' - 6"3' - 0"3' - 0"1' - 0"2' - 0"41-SA-A40310' - 0"1' - 4"3' - 8 1/2"3' - 8 1/2"1' - 5"3' - 0"3' - 0"3' - 0"19' - 11"1' - 9 1/4"8' - 3 3/4"5' - 0"5' - 0"5' - 0"5' - 0"5' - 5 1/2"GRAPHICS PROVIDED BY OWNERMARLITE PANEL SYSTEM OVER GYPSUM WALL BOARD OVER METAL STUDSKAWNEER TRIFAB 451 STOREFRONT OR APPROVED EQUAL3' - 0"3' - 0"3' - 0"1' - 0"10' - 0"71-SA-A403LEVEL 213' - 6"2' - 0"10 3/4"3' - 1 1/4"3' - 0"1' - 0"41-SA-A4031' - 4"3' - 8 1/2"3' - 8 1/2"1' - 5"1' - 0"1' - 10 3/4"7' - 1 1/4"1' - 0"3' - 0"3' - 0"3' - 0"4' - 8 1/8"5' - 0"5' - 0"5' - 5 7/8"5"4' - 1 1/8"5' - 0"5' - 0"5' - 0"5' - 0"4' - 1 3/4"6' - 3 3/4"GRAPHICS PROVIDED BY OWNERMARLITE PANEL SYSTEM OVER GYPSUM WALL BOARD OVER METAL STUDSKAWNEER 350 AUTOMATIC DOORKAWNEER TRIFAB 451 STOREFRONT OR APPROVED EQUAL10' - 0"71-SA-A4032' - 0"1' - 0"3' - 0"3' - 0"3' - 1"1' - 6 3/4"6' - 0"1' - 6 3/4"3' - 1"MARLITE WOOD PANEL SYSTEMKAWNEER 350 DOOR WITH AUTOMATIC DOOR OPENERKAWNEER TRI FAB 451 WITH TEMPERED GLAZINGGYPSUM WALL BOARD SOFFIT PAINTED1-SA-A4036LEVEL 213' - 6"OPENMARLITE PANEL SYSTEM OVER GYPSUM WALL BOARD OVER METAL STUDSBAGGAGE CLAIMNO RE-ENTRYSECURITY EXITB2-02PASSENGER WAITING AREAB2-136" 20 GAUGE METAL STUDS AT 24" O.C.CONTINUOUS RUNNERS -TOP AND BOTTOM3 5/8" CONTINUOUS RUNNERSUSPENDED 5/8" GYPSUM WALL BOARD -PAINTEDCEILING HEIGHT10' - 0"CEILING HEIGHT10' - 0"MARLITE PANEL SYSTEMMARLITE PANEL SYSTEM REVEAL5/8" GYPSUM WALL BOARD PAINTEDCEILING PANEL SYSTEMGRAPHICS INSERT -REFER TO SPECIFICATIONSKAWNEER TRI FAB 451 INTERIOR STOREFRONT SYSTEMWALL HEIGHT9' - 0"ANGLED WALL SUPPORTS AT 48" O.C. -ALTERNATE STUD ANGLE EVERY OTHER STUD -FASTEN TO DECK ABOVE6"7 1/2"4 1/2"INTERIOR ALUMINUM WINDOW SYSTEM WITH KAWNEER TRIFAB 451 WINDOW SYSTEM AS DESIGN BASISFLOOR FINISHCONCRETE SLAB3/8"2"INTERIOR ALUMINUM WINDOW SYSTEM WITH KAWNEER TRIFAB 451 WINDOW SYSTEM AS DESIGN BASIS2"1/4" CLEAR GLASSTYPICAL STOREFRONT INTERMEDIATE FRAMINGTYPICAL STOREFRONT INTERMEDIATE FRAMINGSTAINLESS STEEL STANDOFF CLIP WITH REMOVEABLE FRONT PLATE. ATTACH TO STOREFRONT SYSTEM3/16" POLYCARB PANEL WITH APPLIED GRAPHIC ART9' - 0"3' - 0"3' - 0"3' - 0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 10:37:40 AM1-SA-A403PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAENLARGED PLAN AND INTERIOR ELEVATIONS -SECURITY EXIT - SCREENING AREA07-14-2017S12014 1/4" = 1'-0"1FLOOR PLAN - SCREENING AREA - 2ND FLOOR SECURITY EXIT 1/4" = 1'-0"3ELEVATION AT SECURITY EXIT 1/4" = 1'-0"2ELEVATION AT SECURITY EXIT 1/2" = 1'-0"4SECTION @ SECURITY EXIT CORRIDOR 1/2" = 1'-0"5ELEVATION AT SECURITY ENTRANCENNORTHCLCLCLCLCLCLCLCLCLCL 1 1/2" = 1'-0"6SECTION DETAIL - STOREFRONT SOFFIT 3" = 1'-0"7SECTION @ SECURITY EXIT GLASSREVISIONS# DATEDESCRIPTIONBYCONFORMED SET134
NEW DOOR OPENING FOR ROOF ACCESSNEW 12 GA. METAL STUD DOOR HEADNEW STEEL CHANNEL FOR DOOR SILL VERIFY HEIGHT FROM ROOF SIDE - WELD TO EXISTING COLUMNS ON BOTH SIDES OF OPENING -PAINTEDEXISTING CONCRETE SLABEXISTING WALL GIRTNEW PREFINISHED .032 ALUMINUM WALL FLASHINGNEW 60MIL. TPO ROOF MEMBRANE OVER EXISTING ROOF STRUCTUREEXISTING WOOD BLOCKING TO BE REPLACED WHEN NEW ROOF IS ATTACHED1' - 9"(5) TREADS AT 10"4' - 3"(6) RISERS AT 8 1/4" V.I.F.3' - 11 1/2"EXISTING MECHANICAL ROOMB2-01NEW HANDRAILNEW PRE-FABRICATED ALUMINUM STAIRSEXISTING METAL WALL PANELGYPSUM WALL BOARD -PAINTEDRELOCATE ALL EXISTING CONDUIT, ELECTRICAL WIRING AND DUCT WORK IN NEW DOOR OPENING AREA.ASSUMED WALL THICKNESS. V.I.F. NO AS-BUILTS OF WALL CONSTRUCTION1-SA-A60271-SA-A60211ALUMINUM GRATE TREADSALUMINUM THRESHOLD SET IN SEALANTPREFINISHED STEEL EDGE FLASHINGNEW DOOR OPENING CONSIST OF STEEL CHANNELS ON BOTH JAMBS EXTENDING FROM EXISTING GRIT TO EXISTING GIRT. SILL WILL BE MADE OF NEW STEEL CHANNEL EXTENDING FROM EXISTING COLUMN TO EXISTING COLUMN AND DOOR HEAD WILL BE 12 GA METAL STUDS EXTENDING FROM CHANNEL TO CHANNEL500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1 1/2" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/4/2017 3:29:21 PM1-SA-A501PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADETAILS - SCREENING AREA07-14-2017S12014 1 1/2" = 1'-0"1SECTION AT NEW DOOR OPENINGORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY135CONFORMED SET
29'-8"29'-1"28'-5"2'5'-10"12'-4"11'-2"12'-4"11'-10"12'-4"12'-5"12'-4"5'-3"10'1'-6"10'-10"3'-8"2'-7"2'4'-1"4'-8"5'-7"4'3'-5"8'-8" 8'-1" 7'-6"1'-6"1'-6"6"12'-9"5'3'1'-6"6'10'-3"9'-7"TDC #8TDC #7TDC #6TDC #5TDC #4TDC #3TDC #2TDC #1BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONTL3ENTEREXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONTL3ENTEREXITTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATAVSAVSFRONTETDBLS
AVSAVSFRONTETDBLS
FRONTETDBLSAVSFRONTETDBLSAVSAVSAVSFRONTETDBLS 23'-9"3'LADA GATEWTMDCEIA12ETDETDETDETD
LL43L43L3L323'-9"3'LADA GATEWTMDCEIA1 23'-9"3'LADA GATEWTMDCEIA123'-9"3'LADA GATEWTMDCEIA1B2-03AB2-08B2-09B2-10B2-03B2-15B2-01B2-12EXISTING MECHANICAL ROOMB2-01EXISTING TICKETINGB1-10SECURITY EXITB2-02SECURITY CHECKPOINT SCREENINGB2-12SECURITY OFFICEB2-08WOMENS ROOMB2-04MENS ROOMB2-05RECEPTIONB2-10OPPS MANAGER OFFICEB2-11PSRB2-15PASSENGER WAITING AREAB2-13ELEVATOR 3B1-48ELEVATOR 4B1-49EXPANDED SCREENING AREAB2-14PENTHOUSEB2-16BAGGAGE CLAIM ROOFB2-17CORRIDORB2-18CORRIDORFP2-01OFFICEFP2-02CONFERENCE ROOMFP2-03OFFICEFP2-04OFFICEFP2-05CONFERENCE ROOMFP2-06OFFICEFP2-08.OFFICEFP2-07OFFICEFP2-09RECEPTIONFP2-10RESTROOMFP2-12ELECTRICALFP2-13RESTROOMFP2-14BREAK ROOMFP2-15RESTROOMFP2-16RoomFP2-17OFFICEFP2-18OFFICEFP2-19STORAGEFP2-20OFFICEFP2-21CANOPYFP2-22ELEVATORFP2-23STAIRSFP1-04TSA IT CABINETB2-07SAA ITB2-09JANITORB2-06CORRIDORB2-03B2-02Generic - 6"Generic - 6"Generic - 6"Generic - 6"Generic - 6"B2-02AGeneric - 6"Generic - 6"B2-06Generic - 6"LOST AND FOUNDB2-11BOPPS DIRECTOR OFFICEB2-11AB2-11B2-11AGeneric - 6"B2-11BB2-19AB2-19WALL TYPE LEGENDNEW WALLEXISTING WALLDOOR TAG - REFER TO SCHEDULE#NEW MASONRY WALL500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 2:02:53 PM1-SA-A601PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADOOR SCHEDULE KEY PLAN - SCREENING AREA07-14-2017S12014 1/16" = 1'-0"1KEYPLAN - SCREENING AREAORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTHREVISIONS# DATE DESCRIPTION BYCONFORMED SET136
ROLL UP DOOR14 GA. DOUBLE METAL STUD JAMBSTAINLESS STEEL METAL TRIM5/8" GWB - PAINTED5/8" GWB - PAINTEDMETAL STUD WALLCONTINUOUS SEALANTHEADPLATE BEYONDPUBLIC SIDESECURITY SIDE5/8" GYPSUM WALL BOARD - PAINTED -PATCH TO MATCH EXISTINGPUBLIC SIDESECURITY SIDEMETAL STUD WALL FLAME BAFFLEPROTECTIVE STEEL HOODSTAINLESS STEEL TRIM PIECE12GA. METAL STUD WALL HEADERCONTINUOUS SEALANTBATT INSULATION5/8" GYPSUM WALL BOARD - PAINTED -PATCH TO MATCH EXISTING5/8" GYPSUM BOARD BOTH SIDES3 5/8" METAL STUDS PER WALL TYPESOLID CORE WOOD DOOR BATT INSULATION REFERTO WALL TYPESHOLLOW METAL FRAME7'-0" A.F.F.5/8" GYPSUMBOARD BOTHSIDESDOUBLE 3 5/8"METAL STUDS PER WALL TYPEHOLLOW METALFRAMESOLID CORE WOOD DOOR BATT INSULATION REFERTO WALL TYPES7' - 0"2"MATCH EXISTING HEIGHTCARD READER7' - 2"2"3' - 0"2"3' - 4"SINGLE FLUSH WOOD DOORROLLING SECURITY DOOR15' - 0"10' - 0"1 LAYER 1/2" AND 1 LAYER 3/8" CLEAR POLYCARB GLAZING EACH SIDE OF GRAPHIC IMAGESTOREFRONT FRAME AT TRANSOM ALUMINUM DOORALUMINUM STOREFRONT MULLION1 LAYER 1/2" AND 1 LAYER 3/8" CLEAR POLYCARB WITH GRAPHIC IMAGE BETWEEN.ALUMINUM DOORSEALANT, BOTH SIDESMETAL SIDING ON HAT CHANNELS7'-0" A.F.F.EXTERIOR SHEATHINGPREFINISHED STEEL EDGE FLASHINGSEALANT, BOTH SIDESBATT INSULATION. REFER TO WALL TYPE5/8" GYPSUM BOARDMETAL SIDING ON HAT CHANNELSHOLLOW METAL FRAME & DOOR6" METAL STUDS PER WALL TYPEEXTERIOR SHEATHINGDOORHOLLOW METAL DOORFRAMEMETAL THRESHOLD SET IN FULLBED OF MASTICMETAL SIDING BEYONDADD SIGN TO FRONT FACE OF ALL DOORS THAT ENTER INTO SECURE AREAHEIGHT = 18"WIDTH = 18"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/4/2017 11:37:34 AM1-SA-A602PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADOOR SCHEDULE, DOOR ELEVATIONS ANDDETAILS - SCREENING AREA07-14-2017S12014ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDDOOR SCHEDULE - SCREENING AREASAA #CARDREADERDoor #Room NameDoor SizeDoorLabelDetailsFrameHardwareSetCommentsWidth Height Thickness Door Material Door FinishHead Jamb ThresholdMaterialFinishNO B2-01 EXISTING MECHANICALROOM3' - 0" 7' - 0" 1 3/4" HOLLOW METALPAINT7/1-SA-A602 8/1-SA-A602 11/1A-SA-A602 HOLLOW METALPAINT2NO B2-02 SECURITY EXIT6' - 0" 7' - 0" 1 3/4" ALUMINUM/POLYCARB ALUM4/1-SA-A602 5/1-SA-A602ALUMINUM21NO B2-02A SECURITY EXIT6' - 0" 7' - 0" 1 3/4" ALUMINUM/POLYCARB ALUM4/1-SA-A602 5/1-SA-A602ALUMINUM21YES B2-03 CORRIDOR3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 12YES B2-03A CORRIDOR3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 12NO B2-06 JANITOR3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT6YES B2-08 SECURITY OFFICE3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 23YES B2-09 SAA IT3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 12NO B2-10 TERMINAL OPPERATIONS 3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 23NO B2-11 TERMINAL OPPERATIONS 3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 23NO B2-11A TERMINAL OPPERATIONS 3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 23NO B2-11B TERMINAL OPPERATIONS 3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 23NO B2-12 SECURITY CHECKPOINTSCREENING15' - 0" 10' - 0" 1 3/4" STEELPREFINISHED9/1-SA-A602 10/1-SA-A602STEELPREFINISHED 1NO B2-15 PSR3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-SA-A602 3/1-SA-A602HOLLOW METALPAINT 24YES B2-19 EGRESS CORRIDOR 3' - 0" 7' - 0" 1 3/4" HOLLOWE METALPAINT7/1-SA-A602 8/1-SA-A602 11/1A-SA-A602 HOLLOW METALPAINT 18NO B2-19A EGRESS CORRIDOR 3' - 0" 7' - 0" 1 3/4" ALUMINUM/GLASSALUM4/1-SA-A602 5/1-SA-A602ALUMINUM1 3" = 1'-0"10SECURITY BELT ROLL UP DOOR JAMB 3" = 1'-0"9SECURITY ROLL UP DOOR HEAD 3" = 1'-0"2INTERIOR DOOR HEAD 3" = 1'-0"3INTERIOR DOOR JAMB 1/2" = 1'-0"1DOOR ELEVATIONS 3" = 1'-0"4STOREFRONT TRANSOM 3" = 1'-0"5STOREFRONT MULLION/DOOR 3" = 1'-0"7DOOR HEAD DETAIL 3" = 1'-0"8EXTERIOR H/M DOOR JAMB 3" = 1'-0"11THRESHOLD @ DOOR TO ROOFGENERAL NOTE: IF DOOR DOES NOT HAVE A CARD READER THEN IT WILL REQUIRE A LOCK AND KEY. KEYING WILL REQUIRE COORDINATION WITH S.A.A.REVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 44137CONFORMED SET
PSRB2-15EXPANDED SCREENING AREAB2-14OFFICEFP2-0233314' - 0"18' - 7"14' - 0"5' - 7 3/4"14' - 0"9' - 0 3/4"14' - 0"3' - 6"3' - 6"3' - 6"3' - 6"4' - 0"WINDOW TYPE 3KAWNEER IR501T OR ARCHITECT APPROVED EQUAL WITH HIGH IMPACT GLAZINGHOLLOW METAL FRAME BY KAWNEER MODEL IR501T OR ARCHITECT APPROVED EQUALSEALANT - BOTH SIDES3/8" SHIM4"5/8" GYPSUM WALL BOARD - PAINTEDCORNER J-BEADDOUBLE STUD HEADERINSULATED WINDOW GLAZING6" METAL STUDSR-13 BATT INSULATION5/8 EXTERIOR DENSGLASS SHEATHINGNEW PREFINISHED METAL PANEL SIDINGCONTINUOUS METAL PANEL CLOSUREPRE-FINISHED METAL PANEL DRIP EDGE FLASHINGCONTINUOUS HAT CHANNELSHOLLOW METAL FRAME OR SIMILARSEALANT - BOTH SIDES3/8" SHIM4"5/8" GYPSUM WALL BOARD - PAINTEDCORNER J-BEADDOUBLE STUD HEADERINSULATED WINDOW GLAZING6" METAL STUDSR-13 BATT INSULATION5/8 EXTERIOR GRADE SHEATHINGNEW METAL PANEL SIDINGCONTINUOUS METAL PANEL CLOSUREPRE-FINISHED METAL PANEL EDGE FLASHINGCONTINUOUS HAT CHANNELSMETAL FRAMESILL TOP TRIM PIECE5/8" GYPSUM WALL BOARD - PAINTEDTHROUGH WALL ALUMINUM WALL CAPMETAL SUB STILL3/8" SHIMINSULATED WINDOW GLAZING6" METAL STUDSR-13 BATT INSULATION5/8 EXTERIOR DENSGLASS SHEATHINGNEW PREFINISHED METAL PANEL SIDINGCONTINUOUS METAL PANEL CLOSUREPRE-FINISHED METAL PANEL DRIP EDGE .04 BRAKE METAL SUB SILL FLASHINGCONTINUOUS HAT CHANNELS500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 2:03:29 PM1-SA-A603PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAWINDOW SCHEDULE AND KEY PLAN - SCREENINGAREA07-14-2017S12014ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUND 1/8" = 1'-0"5WINDOW SCHEDULE KEY PLAN - SCREENING AREANNORTH 3/4" = 1'-0"4WINDOW TYPES 3" = 1'-0"1WINDOW HEAD DETAIL 3" = 1'-0"2WINDOW JAMB DETAIL 3" = 1'-0"3WINDOW SILL DETAILREVISIONS# DATE DESCRIPTION BYCONFORMED SET138
29'-8"29'-1"28'-5"2'5'-10"12'-4"11'-2"12'-4"11'-10"12'-4"12'-5"12'-4"5'-3"10'1'-6"10'-10"3'-8"2'-7"2'4'-1"4'-8"5'-7"4'3'-5"8'-8"8'-1"7'-6"1'-6"1'-6"6"12'-9"5'3'1'-6"6'10'-3"9'-7"TDC #8TDC #7TDC #6TDC #5TDC #4TDC #3TDC #2TDC #1BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F1,800 lbs 102"High57 PSIFloor Load2" Clearance 5' or below6" Clearance 5' or aboveFRONTL3ENTEREXIT
BINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLEBINSEMPTYBINSEMPTYBINSEMPTYBINSEMPTYAT26040 aTiX60" DIVEST TABLE60" DIVEST TABLERoofMinimum Ceiling Height = 9' (108")100-120V - 16A, 50Hz/60Hz220-240V - 8A, 50Hz/60Hz32 F - 95 F
1,800 lbs
102"High57 PSIFloor Load
2" Clearance 5' or below6" Clearance 5' or above
FRONTL3ENTEREXIT TDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATTDC/CATAVSAVSFRONTETDBLS
AVSAVSFRON
TETDBLS
FRON
TETDBLSAVSFRONTETDBLSAVSAVSAVSFRONTETDBLS 23'-9"3'LADA GATEWTMDCEIA12ETDETDETDETDLL43L43L3L3
23'-9"3'LADA GATEWTMDCEIA1 23'-9"3'LADA GATEWTMDCEIA123'-9"3'LADA GATEWTMDCEIA1
UPSAA ITB2-09SECURITY OFFICEB2-08TSA IT CABINETB2-07CORRIDORB2-03WOMENS ROOMB2-04MENS ROOMB2-05OPPS MANAGER OFFICEB2-11RECEPTIONB2-10CORRIDORB2-18SECURITY EXITB2-02EXISTING MECHANICAL ROOMB2-01SECURITY CHECKPOINT SCREENINGB2-12CONFERENCE ROOMFP2-03OFFICEFP2-02CORRIDORFP2-01PSRB2-15EXPANDED SCREENING AREAB2-14PASSENGER WAITING AREAB2-13JANITORB2-06TILE START POINT, COORDINATE GROUT LINES WITH WALL TILE GROUT LINES3' - 0"10' - 3 3/4"3' - 0"152' - 7 3/8"R 4 0 ' - 5 3 /4"R 3 8 ' - 5 3 /4 "R 18' - 1 7/8"R 1 6 ' - 1 7 /8 "2' - 0"3' - 0"1' - 0"5' - 9 1/4"22' - 1 5/8"42' - 8 1/2"LOST AND FOUNDB2-11BOPPS DIRECTOR OFFICEB2-11ATZ1TZ2C1TZ1C1C1C1C1C1C1C1C1C1T1T13FINISH LEGENDCARPETCARPET ACCENTCARPET ACCENTVCTTILE FLOORINGTERRAZZO TILETERRAZZO TILE ACCENTTERRAZZO TILE ACCENTCHILDREN PLAY AREAFLOORINGSEALED CONCRETERECESSED WALK-OFF MATMILLWORKGENERAL NOTES1. REFER TO ELEVATIONS FOR LOCATION OF ADDITIONAL WALL SURFACE FINISH.2. REFER TO CEILING PLANS FOR CEILING FINISH LOCATION.3. REFER TO GENERAL SHEET G-106 FOR FINISHES.4. ALL FLOOR FINISHES EXTEND TO ADJACENT WALLFLOOR TILE INSTALLATION NOTES1. ALL CONCRETE FLOORS MUST BE TESTED FOR MOISTURE AND PH PRIOR TO INSTALLATION.2. REFER TO SPECIFICATIONS FOR MOISTURE AND PH LEVEL TOLERANCES.3. SUBSTRATE MUST BE FLAT WITHIN THE EQUIVALENT OF 1/8" IN 10'-0".4. SUBSTRATE MUST BE FREE OF ADHESIVE, SEALERS, PAINT, COATINGS, FINISHES, DIRT, FILM FORMING CURING COMPOUNDS, OR OTHER SUBSTANCES THAT MAY AFFECT THE ADHESION OF THE FLOORING.5. DO NOT INSTALL FLOOR TILE BEFORE ALL OTHER TRADES ARE FINISHED.6. ALL MATERIALS MUST BE ON SITE IN THE ROOM WHERE THEY WILL BE INSTALLED 48 HOURS BEFORE INSTALLATION. TILE MUST BE STORED BEHIND TEMPORARY CONSTRUCTION WALL.7. CLOSE SPACES TO TRAFFIC 12 HOURS BEFORE INSTALLATION AND 24 HOURS AFTER INSTALLATION IS COMPLETE.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/4/2017 11:42:30 AM1-SA-A701PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH PLAN AND SCHEDULE - SCREENING AREA07-14-2017S12014 3/32" = 1'-0"1FINISH PLAN - SCREENING AREAORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTHFINISH SCHEDULE - SCREENINGRM. NO. ROOM NAMEAreaFLOORBASEWALL FINISHESCEILINGNOTESNorth Finish East Finish South Finish West FinishB2-01 EXISTING MECHANICALROOM1399 SFEXISTINGEXISTING EXISTING EXISTING EXISTING EXISTING EXISTINGB2-02 SECURITY EXIT536 SFCARPETNONE N/A N/A N/AN/ACEILING TILES 4 SIDES STOREFRONT APPLICATIONB2-03 CORRIDOR196 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-04 WOMENS ROOM396 SFPORCELAIN TILETILE TILE TILETILE TILEPAINTB2-05 MENS ROOM398 SFPORCELAIN TILETILE TILETILE TILE TILEPAINTB2-06 JANITOR52 SFPORCELAIN TILETILE FRP/PAINT FRP/PAINT FRP/PAINT FRP/PAINT PAINTB2-07 TSA IT CABINET9 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-08 SECURITY OFFICE 357 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-09 SAA IT228 SFCARPETVINYL PAINTPAINT PAINT PAINT CEILING TILESB2-10 RECEPTION192 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-11 OPPS MANAGER OFFICE 171 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-11A OPPS DIRECTOR OFFICE 220 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-11B LOST AND FOUND 61 SFVCTVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-12 SECURITY CHECKPOINTSCREENING7692 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-13 PASSENGER WAITINGAREA13319 SFEXISTINGEXISTING EXISTING EXISTING EXISTING EXISTING EXISTINGB2-14 EXPANDED SCREENINGAREA4826 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-15 PSR49 SFCARPETVINYL PAINT PAINT PAINT PAINT CEILING TILESB2-20 IT29 SFVCTVINYL PAINT PAINT PAINT PAINTEXISTINGB2-21 TERMINAL B27545 SFCARPET/FRITZ TILEVINYL PAINT PAINT PAINT PAINT EXISTING CEILINGTILES &SOFFITS(PAINT)NOTE: ALL COLUMNS IN PUBLIC SPACE TO RECEIVE MARLITE SYSTEM AND PAINT. REFER TO DETAILS 6 AND 7 ON SHEET G116 UNLESS NOTED OTHERWISE. PROVIDE BOX EXTENSIONS FOR ALL ELECTRICAL AND COMMUNICATIONS OUTLETS AS NECESSARY, REFER TO MEP DRAWINGS.REVISIONS# DATEDESCRIPTIONBY3 08-25-2017 ADDENDUM 3139CONFORMED SET
UNKR 3' - 0"4' - 3 1/2"R 1' - 0"PASSENGER WAITING AREAB2-13CORRIDORB2-18CORRIDORB2-03SECURITY EXITB2-02C1TZ1TZ1TZ1TZ1TZ2TZ2TZ2TZ2TZ2TZ2TZ3TZ3R 13' - 11"R 1 3 ' - 0 1 /8 "R 3 3 ' - 8 1 /8 "R 30' - 6"R 34' - 1 1/2"R 52' - 1 1/4"1' - 1 1/2"3' - 2 1/4"7' - 7 3/4"1' - 0"1' - 1 1/2"18' - 9 3/4"EQ5' - 7 3/4"EQ1' - 0"3' - 0"2' - 0"R 15' - 1 1"
R 2 1 ' - 9 1 /8 "2' - 0"VIF6' - 8 1/4"9' - 3"9' - 3"7' - 0"C1C1126' - 0 1/2"40' - 11 3/4"R 1 9' - 2 "R 21' - 2"TZ3TZ1TZ2TZ24' - 10"9' - 3"9' - 3"4' - 10"6 3/4"6 1/4"EXPANSION JOINTFUTURE PHASE 2 TICKETING EXPANSIONFINISH LEGENDCARPETCARPET ACCENTCARPET ACCENTVCTTILE FLOORINGTERRAZZO TILETERRAZZO TILE ACCENTTERRAZZO TILE ACCENTCHILDREN PLAY AREAFLOORINGSEALED CONCRETERECESSED WALK-OFF MATMILLWORKGENERAL NOTES1. REFER TO ELEVATIONS FOR LOCATION OF ADDITIONAL WALL SURFACE FINISH.2. REFER TO CEILING PLANS FOR CEILING FINISH LOCATION.3. REFER TO GENERAL SHEET G-106 FOR FINISHES.4. ALL FLOOR FINISHES EXTEND TO ADJACENT WALLFLOOR TILE INSTALLATION NOTES1. ALL CONCRETE FLOORS MUST BE TESTED FOR MOISTURE AND PH PRIOR TO INSTALLATION.2. REFER TO SPECIFICATIONS FOR MOISTURE AND PH LEVEL TOLERANCES.3. SUBSTRATE MUST BE FLAT WITHIN THE EQUIVALENT OF 1/8" IN 10'-0".4. SUBSTRATE MUST BE FREE OF ADHESIVE, SEALERS, PAINT, COATINGS, FINISHES, DIRT, FILM FORMING CURING COMPOUNDS, OR OTHER SUBSTANCES THAT MAY AFFECT THE ADHESION OF THE FLOORING.5. DO NOT INSTALL FLOOR TILE BEFORE ALL OTHER TRADES ARE FINISHED.6. ALL MATERIALS MUST BE ON SITE IN THE ROOM WHERE THEY WILL BE INSTALLED 48 HOURS BEFORE INSTALLATION. TILE MUST BE STORED BEHIND TEMPORARY CONSTRUCTION WALL.7. CLOSE SPACES TO TRAFFIC 12 HOURS BEFORE INSTALLATION AND 24 HOURS AFTER INSTALLATION IS COMPLETE.5. PAINT ALL JOIST AND EXPOSED SURFACES ABOVE WITH DRY FALL PAINT500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/4/2017 11:48:55 AM1-SA-A702PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH PLAN - SCREENING AREA CONTINUED07-14-2017S12014 3/32" = 1'-0"1FINSH PLAN - SCREENING AREA CONTINUEDORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDTERMINAL BNNORTHNOTE: ALL COLUMNS IN PUBLIC SPACE TO RECEIVE MARLITE SYSTEM AND PAINT. REFER TO DETAILS 6 AND 7 ON SHEET G116 UNLESS NOTED OTHERWISE. PROVIDE BOX EXTENSIONS FOR ALL ELECTRICAL AND COMMUNICATIONS OUTLETS AS NECESSARY, REFER TO MEP DRAWINGS.REVISIONS# DATEDESCRIPTIONBY140CONFORMED SET
Table
Table
TableTableTableTableTable TZ1TZ2TZ3TZ3C19' - 3"9' - 3"EQEQ28' - 2 1/2"R 2 1 ' - 4 7 /8 "R 23' - 6 3/4"1' - 0 3/4"TZ2EXISTING VINYL FLOORINGC1C1C1C1ITB2-20NEW LOADING DOCK ELEVATORB1-16TERMINAL BB2-21FINISH LEGENDCARPETCARPET ACCENTCARPET ACCENTVCTTILE FLOORINGTERRAZZO TILETERRAZZO TILE ACCENTTERRAZZO TILE ACCENTCHILDREN PLAY AREAFLOORINGSEALED CONCRETERECESSED WALK-OFF MATMILLWORKGENERAL NOTES1. REFER TO ELEVATIONS FOR LOCATION OF ADDITIONAL WALL SURFACE FINISH.2. REFER TO CEILING PLANS FOR CEILING FINISH LOCATION.3. REFER TO GENERAL SHEET G-106 FOR FINISHES.4. ALL FLOOR FINISHES EXTEND TO ADJACENT WALLFLOOR TILE INSTALLATION NOTES1. ALL CONCRETE FLOORS MUST BE TESTED FOR MOISTURE AND PH PRIOR TO INSTALLATION.2. REFER TO SPECIFICATIONS FOR MOISTURE AND PH LEVEL TOLERANCES.3. SUBSTRATE MUST BE FLAT WITHIN THE EQUIVALENT OF 1/8" IN 10'-0".4. SUBSTRATE MUST BE FREE OF ADHESIVE, SEALERS, PAINT, COATINGS, FINISHES, DIRT, FILM FORMING CURING COMPOUNDS, OR OTHER SUBSTANCES THAT MAY AFFECT THE ADHESION OF THE FLOORING.5. DO NOT INSTALL FLOOR TILE BEFORE ALL OTHER TRADES ARE FINISHED.6. ALL MATERIALS MUST BE ON SITE IN THE ROOM WHERE THEY WILL BE INSTALLED 48 HOURS BEFORE INSTALLATION. TILE MUST BE STORED BEHIND TEMPORARY CONSTRUCTION WALL.7. CLOSE SPACES TO TRAFFIC 12 HOURS BEFORE INSTALLATION AND 24 HOURS AFTER INSTALLATION IS COMPLETE.5. PAINT ALL JOIST AND EXPOSED SURFACES ABOVE WITH DRY FALL PAINT500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 2:08:53 PM1-SA-A703PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH PLAN - TERMINAL B07-14-2017S12014 3/32" = 1'-0"1FLOOR FINISH PLAN - TERMINAL B 2ND FLOORORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDTERMINAL BNNORTHNOTE: ALL COLUMNS IN PUBLIC SPACE TO RECEIVE MARLITE SYSTEM AND PAINT. REFER TO DETAILS 6 AND 7 ON SHEET G116 UNLESS NOTED OTHERWISE. PROVIDE BOX EXTENSIONS FOR ALL ELECTRICAL AND COMMUNICATIONS OUTLETS AS NECESSARY, REFER TO MEP DRAWINGS.REVISIONS# DATEDESCRIPTIONBYCONFORMED SET141
11c8a8aWOMENS ROOMB2-04EQ1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"EQOPEN TO BEYOND21b21a21d1' - 1"2' - 0"1' - 5"133a2' - 10"3' - 4"2' - 10"21b11c8a8aMENS ROOMB2-059"7' - 0"9"5"1' - 2"3a1321a21b21dOPEN TO BEYOND1' - 8"2' - 0"11 3/8"2' - 0"2' - 0"3' - 4"1245a8c6b11a5e4994' - 6"3' - 0"1' - 0"2' - 0"1' - 11 1/8"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"11 3/8"5e6a22TYP.1021a21b21d1' - 7"2' - 10"3' - 3"1245b8c5e4WOMENS ROOMB2-0411a1' - 0"1' - 0"1' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"1' - 6"1' - 0"2' - 0"1' - 11 3/4"6b6a6a5e21b21a21d5e5e5e44447a7a6b6c11c8a47a5eWOMENS ROOMB2-0421a21d2' - 0"7"2' - 0"2' - 0"2' - 0"2' - 0"6a2' - 10"1' - 4"47a8a11cWOMENS ROOMB2-045e6a21a21d2' - 10"11c8a46a5e21a21d5 1/2"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"8"7"1' - 6"2' - 10"98a11c2' - 0"HALF WALL4' - 6"COUNTER TOP TO MATCH ADJACENT8"2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"5 1/2"1' - 6"7"22#136" GRAB BAR242" GRAB BAR3BABY CHANGING TABLEa. SOLID SURFACE BABY CHANGING TABLE WITH INTEGRAL 4" FRONT EDGEb. STAINLESS STEEL RECESSED BABY CHANGING STATIONc. SURFACE MOUNTED ADA CHANGING STATION4WALL/ FLOOR MOUNTED TOILET - FLUSH VALVE ON OPEN SIDE OF SPACE IN ALL ADA STALLS - REFER TO PLUMBING5TOILET PAPER DISPENSERa. RECESS MOUNTED JUMBO TISSUE DISPENSERb. RECESS MOUNTED JUMBO TISSUE DISPENSER WITH SANITARY NAPKIN DISPOSALc. NOT USEDd. NOT USEDe. PARTITION/WALL MOUNTED JUMBO DISPENSER7SANITARY NAPKIN DISPOSALa. SHARED PARTITION MOUNTEDb. PARTITION SURFACE MOUNTEDc. RECESSED8MIRRORa. 24" X 36" WALL MOUNTEDb. 24" X 48" WALL MOUNTEDc. 18" X 36" WALL MOUNTED9WALL MOUNTED URINAL10SOLID SURFACE COUNTER WITH 1 1/2" INTEGRAL FRONT EDGE. COUNTER MOUNTED AT 5'-0" AFF.11SINKS - REFER TO PLUMBING & ELECTRICAL DRAWINGSa. ADA SINGLE SOLID SURFACE TROUGH SINK WITH TOUCHLESS HANDWASHING CONTROLb. CONTINUOUS SOLID SURFACE TROUGH SINK AND 2 TOUCHLESS WASH BAR. c. CONTINUOUS SOLID SURFACE TROUGH SINK AND 3 TOUCHLESS WASH BAR. d. STANDARD ADA COMPLIANT WALL MOUNTED SINK WITH ADA FAUCET CONTROLSe. ADA COMPLIANT DROP IN SINK AND FAUCETRESTROOM LEGEND12ADA WALL MOUNTED SOAP DISPENSER13ADA WALL MOUNTED DRYERADA COMPLIANT SHOWER SEAT14SHOWER CURTAIN AND ROD15PLASTIC LAMINATE TALL CABINET1617MOP SINK WITH WALL MOUNTED MOP CLIPS18HI / LOW ADA DRINKING FOUNTAINS19WALL MOUNTED COAT HOOKS20ADA RESTROOM WALL SIGNAGE21WALL TILE - REFER TO SHEET G106 FOR FINISHa. FIELD TILEb. ACCENT TILEc. BULLNOSE TILEd. COVE BASE TILE 1. REFER TO SHEET G111 FOR ADA SPECIFICATIONS.2. ALL FIELD WALL TILE GROUT LINES TO ALIGN WITH FLOOR GROUT LINES. 3. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.GENERAL NOTES22TOILET PARTITION23PARTITION MOUNTED COAT HOOKXX24NAPKIN/TAMPON VENDOR6PLASTIC LAMINATE COUNTER WITH 4" BACKSPLASH ON 3 SIDES. COLOR TBD.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 2:06:28 PM1-SA-A711PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINTERIOR ELEVATIONS RESTROOMS - SCREENINGAREA07-14-2017S12014 1/2" = 1'-0"1SCREENING AREA WOMEN'S RESTROOM 1/2" = 1'-0"5SCREENING AREA MEN'S RESTROOM. 1/2" = 1'-0"7SCREENING MEN'S RESTROOM 1/2" = 1'-0"3SCREENING WOMEN'S RESTROOM 1/2" = 1'-0"2SCREENING AREA WOMEN'S RESTROOM. 1/2" = 1'-0"4SCREENING AREA WOMEN'S RESTROOM.. 1/2" = 1'-0"6SCREENING AREA MEN'S RESTROOM 1/2" = 1'-0"8SCREENING AREA MEN'S ROOMREVISIONS# DATE DESCRIPTION BYCONFORMED SET142
2'5'-10"5'-7"4'BINSEMPTYBINSEMPTY6040 aTiXLLEVEL 213' - 6"B10B9B8B7B6B511-SA-A301EQEQEQEQEQEQEQEQEQEQEQ6' - 0"EQEQEQEQEQEQEQEQ2' - 0"9' - 0"42' - 3"EQEQEQEQEQ3' - 0"3' - 0"3' - 0"NEW KAWNEER TRI FAB 451 GLAZING OR ARCHITECT APPROVED EQUAL12' - 0"12' - 0"6" METAL STUD WALL - PAINTEDBHBH.1B5BH.0511-SA-A30121-SA-A30211-SA-A3021-SA-A71231-SA-A71251-SA-A7124B2-19AB2-19LEVEL 213' - 6"BHBH.1BH.0521-SA-A30211-SA-A302NEW KAWNEER TRI FAB 451 GLAZING OR ARCHITECT APPROVED EQUAL4' - 5 3/8"4' - 5 3/8"4' - 5 3/8"4' - 5 3/8"4' - 5 3/8"4' - 5 3/8"4' - 5 3/8"4' - 5 3/8"3' - 0"3' - 0"3' - 0"11' - 0"35' - 7"LEVEL 213' - 6"B511-SA-A301NEW KAWNEER TRI FAB 451 GLAZING OR ARCHITECT APPROVED EQUAL3' - 0"3' - 0"3' - 0"9' - 0"5' - 7 1/2"LEVEL 213' - 6"B511-SA-A301NEW KAWNEER TRI FAB 451 GLAZING OR ARCHITECT APPROVED EQUAL2' - 0"7' - 0"3' - 0"3' - 0"3' - 0"3' - 0"5' - 7 1/2"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/27/2017 10:42:06 AM1-SA-A712PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINTERIOR ELEVATIONS - STOREFRONT -SCREENING AREA07-14-2017S12014 1/8" = 1'-0"1STOREFRONT ELEVATION 1/4" = 1'-0"2SCREENING AREA - EXITCORRIDOR ENLARGED PLAN 1/4" = 1'-0"3STOREFRONT ELEVATION - SCREENING AREA 1/4" = 1'-0"4SCREENING AREA -STOREFRONTELEVATION-NORTH 1/4" = 1'-0"5SCREENING AREA-STOREFRONTELEVATION SOUTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 45 09-22-2017 ADDENDUM 545CONFORMED SET143
DEMOLISH EXISTING STAIRS AND LANDING PLATFORM5' - 0"REMOVE SECTION OF BAGGAGE BELT FOR NEW 5'-0" BAGGAGE BELT EXTENSION5' - 0"DEMOLISH ENTIRE EXISTING FIS RECHECK BAGGAGE BELT AND ALL SYSTEMS ASSOCIATED WITH IT11' - 4"MAKE NEW DOOR OPENINGS IN EXISTING MASONRY WALL FOR NEW RESTROOMS -REMOVE (1) COURSING ABOVE FOR NEW DOOR LINTEL DEMOLISH EXISTING ROLL UP DOOR AND BAGGAGE SLIDE AND RETURN TO OWNERBAGGAGE CLAIM 3FP1-03KITCHENBC3-06CUSTOMS / FIRE PROTECTION AREACOMBINEDFP1-05STAIRSFP1-04ELEVATORFP2-23DEMOLISH CHASE WALL AND PLUMBING PIPESDEMOLISH CONCRETE FOR NEW PLUMBING -REFER TO PLUMBING DRAWINGS FOR EXACT LOCATIONREMOVE AND DISPOSE EXISTING FLOORING IN THIS AREA - PREP EXISTING CONCRETE SLAB TO RECEIVE NEW FLOORING - REFER TO FLOORING LAYOUT FOR LIMITS OF DEMOLITIONREMOVE EXISTING AC UNIT -REFER TO MECHANICALDEMOLISH EXISTING BOLLARDSDEMOLISH EXISTING BOLLARDSDEMOLISH EXISTING WALL EXHAUST FAN AND PREP DUCT TO BE RELOCATEDSELECT DEMOLITION OF EXISTING SERVICE COUNTER AND WALL OPENINGNEW WALL OPENING FOR DOORDEMOLISH OPENING IN EXISTING 4 HOUR WALL FOR NEW ROLL UP DOORDEMOLISH EXISTING WALLS, DOOR AND SECURITY CARD READERREMOVE FLOOR FINSH AND PREP CONCRETE TO RECEIVE NEW FINISH6' - 0"6DEMOLITION PLAN LEGENDITEMS TO DEMOLISHITEMS TO REMAIN500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 9:36:26 AM1-BC3-A100PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADEMOLITION PLAN - BAGGAGE CLAIM 307-14-2017S12014 1/8" = 1'-0"1DEMOLITION PLAN - BAGGAGE CLAIM 3ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANF.I.S. CUSTOMSTERMINAL BTERMINAL ANNORTHJCJCDAKDMAS NOTEDREVISIONS# DATEDESCRIPTIONBY6 09-28-2017 ADDENDUM 6CONFORMED SET144
11-SA-A301BAGGAGE CLAIM 3FP1-03OFFICES / IT ROOMBC3-05FAMILY RESTROOMBC3-04FAMILY RESTROOMBC3-03STORAGEBC3-02STORAGEBC3-01KITCHENBC3-06HVACBC3-0725' - 8"24' - 8"BC3-0715' - 0"15' - 0"2253421-BC3-A101323322BAGGAGE BELT #31-BC3-A40116INFILL EXISTING FLOOR WITH CONCRETE TOPPING TO MATCH EXISTING FLOOR LEVEL AND FINISHNEW (4) HOUR OVERHEAD ROLL UP DOOR38' - 7"EXISTING INTERIOR WALLS WILL NEED TO BE PATCHED AND REPAIREDPATCH, REPAIR AND REPAINT EXISTING INTERIOR WALLS G.C. TO VERIFY IF EXISTING DOOR WILL CLEAR NEW HVAC UNIT31-BC3-A101EXISTING (4) HOUR OVERHEAD ROLL UP DOOR18' - 0"NEW DOOR FURNITURE BY OWNERINFILL EXISTING OPENING WITH METAL STUDS AND DRYWALL - PAINT TO MATCH ADJACENT FINISH AND COLOR3' - 0"3A3A3A3AITBC3-09STAIRSFP1-04ELEVATORFP2-23FLOOR PLAN LEGEND:NEW WALLEXISTING WALLDOOR TAG FOR NEW DOORS1i101AFLOOR ELEVATIONWALL TYPE TAGREFER TO G114 & G115KEY NOTES FLOOR PLAN#1INSTALL NEW BAGGAGE BELT EXTENSIONS IN EXISTING BAGGAGE BELT. SEE DETAIL SHEET2NEW EXTERIOR WALL3NEW DOUBLE DOOR4SCREENING ROOM EXPANSION ABOVE5NEW RESTROOMS - REFER TO ENLARGED PLAN, SHEET 1-BC3-A4016IN-FILL EXISTING CMU WALL AT REMOVED BAGGAGE BELT, TO MATCH EXISTINGHVACBC3-0713' - 6"METAL PANEL SIDING - MATCH ADJACENT FINISH, COLOR AND STYLE5/8" GYPSUM WALL BOARDBATT INSULATIONNEW CONCRETE SLAB - REFER TO STRUCTURAL6" METAL STUDS5/8" GYPSUM WALL BOARD - PAINTED2 1/2" METAL STUDNEW SCREENING AREA CONCRETE SLAB OVER METAL DECKING REFER TO STRUCTURAL FOR THICKNESS AND TYPE0"SET METAL STUD RUNNER ON RUBBER SILL SEALER9' - 0"6"EXISTING CEILING9'-0"EXISTING CEILING9'-10"BOTTOM OF HEADER9'-0"EXISTING 8" CMU WALL OVER EXISTING BRICKNEW LINTEL FOR NEW OPENING -REFER TO STRUCTURAL DRAWINGSEXISTING 4 HOUR CMU WALLNEW 3 HOUR FIRE RATED DOOR -CONCEAL IN CEILING ABOVE5/8" GYPSUM WALL BOARD OVER METAL STUDS -PAINTED3" STAINLESS STEEL TRIM AROUND NEW FIRE DOOR OPENINGEXISTING 2ND FLOOR CONCRETE SLAB (S.A.A. OFFICES)NEW 2X2 CEILING TILENEW GYPSUM WALL BOARD UNDER NEW SOFFITEXISTING CEILING TO REMAIN500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:31:50 AM1-BC3-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFLOOR PLAN AND WALL SECTIONS - BAGGAGECLAIM 307-14-2017S12014 1/8" = 1'-0"1FLOOR PLAN - BAGGAGE CLAIM 3ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTH 1/2" = 1'-0"2SECTION AT HVAC ROOM 3/4" = 1'-0"3SECTION AT NEW FIRE DOOR OPENINGREVISIONS# DATEDESCRIPTIONBY6 09-28-2017 ADDENDUM 66CONFORMED SET145
3' - 8 1/2"12' - 0"BAGGAGE CLAIM 3FP1-03CUSTOMS / FIRE PROTECTION AREACOMBINEDFP1-05STAIRSFP1-04FIS SPACEFIS-02FIRE RISER ROOMFP-06EQEQFP-063312' - 0"12' - 0"IT ROOMA1-50PASSENGER BOARDING BRIDGE PEDESTALTERMINAL ABOVE5/8" THICK (3) COAT SMOOTH FINISH STUCCO - PAINTED OVER NEW 8" REINFORCED CMU MASONRY WALLMASONRY OPENING6' - 0"GENERAL NOTE: IF DOOR DOES NOT HAVE A CARD READER THEN IT WILL REQUIRE A LOCK AND KEY. KEYING WILL REQUIRE COORDINATION WITH S.A.A.DOWEL INTO MASONRY 16" ON CENTERHORIZONTAL CAULK JOINTBC3-0831-BC3-A1024"#5 @ 48" O.C.4" MINIMUM EPOXY EMBEDGROUT SOLIDEXISTING CONCRETE SLAB8" VERTICALLY REINFORCED CMU -PAINTED500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/22/2017 2:11:07 PM1-BC3-A102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFLOOR PLAN - NEW FIRE RISER ROOM AND BLOCKHOUSE ADDITION07-14-2017S12014ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDBLOCK HOUSE ADDITIONFIRE RISER ROOM 1/4" = 1'-0"2FLOOR PLAN - FIRE RISER ROOM 1/4" = 1'-0"1FLOOR PLAN - BLOCKHOUSE ADDITIONREVISIONS# DATEDESCRIPTIONBY5 09-22-2017 ADDENDUM 5 3" = 1'-0"3CMU ATTACHMENT DETAIL5CONFORMED SET146
OSOSOS11-SA-A30121-SA-A30111-SA-A302STORAGEBC3-02FAMILY RESTROOMBC3-03FAMILY RESTROOMBC3-04OFFICES / IT ROOMBC3-05BAGGAGE CLAIM 3FP1-03HVACBC3-07STORAGEBC3-01EXPOSED CEILINGNEW GWB CEILING -PAINTEDEXISTING SOFFIT TO REMAIN9' - 0"9' - 0"9' - 0"EXISTING METAL PANEL SOFFITTO REMAIN REPLACE ACT. LIGHTING TO REMAIN, REMOVE AND REINSTALL AS REQUIRED FOR INSTALLATION OF NEW FIRE PROTECTION. REFER TO FIRE PROTECTION PLANS11-SA-A303EXISTING LIGHT FIXTURES, TILE, AND GRID TO REMAIN.EXISTING ACT AND GRID TO REMAIN. RELOCATE 2 X 4 FIXTURES AS SHOWNLIBRETTO PERORATED METAL CEILING ELEMENT WITH DOWNLIGHTING FIXTURE. REFER TO ELECT.5' - 0 1/4"14 FIXTURES @ 5'-1/4" EA = 75'-3 1/2"5' - 0 1/4"R 27' - 0"R 37' - 0"R 37' - 0"R 37' - 0"R 27' - 0"R 37 ' - 0"
R 2 7 ' - 0 "
R 27' - 0"
R 27' - 0"
R 3 7 ' - 0 "31-BC3-A101NEW ROLL UP DOOR OPENINGALL EXPOSED JOIST TO BE PAINTED AND PROTECTED WITH BIRDSCREENWALK IN COOLERNEW BULKHEAD @ 8'-0" A.F.F.EXPOSED CEILINGREFLECTED CEILING PLAN LEGEND2 X 4 LED LIGHTING FIXTURECEILING SUPPLY DIFFUSER SEE MECHANICAL DWGS.GYP. BOARD CEILING ACCESSEXIT SIGN, ARROW INDICATES EXIT DIRECTION SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATIONINDICATES FINISHED GYP. BOARD CEILING OR SOFFITEMERGENCY LIGHTS RE: ELECTRICAL DRAWINGS2 X 2 LAY-IN ACOUSTICAL TILE IN T-BAR GRID. 1. FIXTURES, CONDUITS, DUCTWORK, PIPING, ETC. SHALL BE INSTALLED AS HIGH AS POSSIBLE.2. ADDITIONAL DIRECTIONAL EXIT SIGNS MAY BE REQUIRED. CONTRACTOR TO VERIFY QUANTITIES AND COORDINATE LOCATIONS IN THE FIELD WITH THE FIRE DEPARTMENT FIRE INSPECTOR.3. EMERGENCY LIGHTING SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE.4. MECHANICAL DIFFUSERS TO MATCH ADJACENT CEILING TILE.5. SEE ELECTRICAL DRAWINGS FOR ALL LIGHT FIXTURES 6. INSTALL NEW SPEAKERS AT EXISTING SPEAKER LOCATIONS IN NEW WORK AREA -TYPICALREFLECTED CEILING GENERAL NOTESRECESSED LED CAN LIGHTINGSURFACE MOUNTED EXTERIOR WALL PACKFIRE SPRINKLER HEADPREFINISHED METAL SOFFIT PANELPREFINISHED HANGING PERFORATED METAL PANELCEILING RETURN DIFFUSER SEE MECHANICAL DWGS.INTERIOR WALL HEIGHT LEGENDFULL HEIGHT WALL ATTACHED TO DECKWALL TO EXTEND TO 6" ABOVE FINISHED CEILING - BRACE TO STRUCTURE ABOVE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:29:23 AM1-BC3-A103PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREFLECTED CEILING PLAN - BAGGAGE CLAIM 307-14-2017S12014NNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUND 1/8" = 1'-0"1REFLECTED CEILING PLAN -BAGGAGE CLAIM 3REVISIONS# DATEDESCRIPTIONBY5 09-22-2017 ADDENDUM 56 09-28-2017 ADDENDUM 656CONFORMED SET147
JJJJJJR 27' - 0"
R 2 7 ' - 0 "R 37' - 0"R 27' - 0"R 38' - 0"R 44' - 0"R 18' - 11"R 24' - 11"R 21' - 10"R 15' - 10"R 3 7 ' - 0 "
R 3 7' - 0"11' - 0"35' - 5"10' - 11 1/2"34' - 10 1/4"6' - 6"2' - 3 1/4"28' - 10"30' - 4"28' - 10"10' - 0"16' - 9"8' - 2"14' - 8"23' - 7"21' - 9"4' - 9"90' - 0" - 18 FIXTURES SPACED @ 5'-0" EA4' - 8"EQEQ22-OB-A103NEW 7/8" THICK (3) COAT SMOOTH FINISH STUCCO CEILING - PHASE 2 WORKSTUCCO CONTROL JOINTSTUCCO CONTROL JOINTEXISTING CANOPY TO REMAIN31-BC3-A1012-OB-A2052CEILING10'-6"B/SOFFIT9'-0"B/LIBRETTO9'-3 1/2"33-IB-A10321-BC3-A105NEW ROLL UP DOOR OPENING IN EXISTING 4 HOUR WALLNEW CANOPY - PHASE 2 WORKINEW CANOPY - PHASE 2 WORKIREFLECTED CEILING PLAN LEGEND2 X 4 LED LIGHTING FIXTURECEILING SUPPLY DIFFUSER SEE MECHANICAL DWGS.GYP. BOARD CEILING ACCESSEXIT SIGN, ARROW INDICATES EXIT DIRECTION SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATIONINDICATES FINISHED GYP. BOARD CEILING OR SOFFITEMERGENCY LIGHTS RE: ELECTRICAL DRAWINGS2 X 2 LAY-IN ACOUSTICAL TILE IN T-BAR GRID. 1. FIXTURES, CONDUITS, DUCTWORK, PIPING, ETC. SHALL BE INSTALLED AS HIGH AS POSSIBLE.2. ADDITIONAL DIRECTIONAL EXIT SIGNS MAY BE REQUIRED. CONTRACTOR TO VERIFY QUANTITIES AND COORDINATE LOCATIONS IN THE FIELD WITH THE FIRE DEPARTMENT FIRE INSPECTOR.3. EMERGENCY LIGHTING SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE.4. MECHANICAL DIFFUSERS TO MATCH ADJACENT CEILING TILE.5. SEE ELECTRICAL DRAWINGS FOR ALL LIGHT FIXTURES 6. INSTALL NEW SPEAKERS AT EXISTING SPEAKER LOCATIONS IN NEW WORK AREA -TYPICALREFLECTED CEILING GENERAL NOTESRECESSED LED CAN LIGHTINGSURFACE MOUNTED EXTERIOR WALL PACKFIRE SPRINKLER HEADPREFINISHED METAL SOFFIT PANELPREFINISHED HANGING PERFORATED METAL PANELCEILING RETURN DIFFUSER SEE MECHANICAL DWGS.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/8" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/5/2017 10:51:05 AM1-BC3-A104PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREFLECTED CEILING PLAN - BAGGAGE CLAIM 1 & 207-14-2017S12014 1/8" = 1'-0"1REFLECTED CEILING - BAGGAGE CLAIM 1 & 2NNORTHEXISTING CEILING GRID SYSTEM TO REMAIN. REPLACE ALL ACOUSTIC CEILING TILES THROUGHOUT UNLESS NOTED OTHERWISE. MAINTAIN FIRE SPRINKLER, HVAC, AND LIGHTING LOCATIONS UNLESS NOTED OTHERWISE NEW PAINTED GYP. BOARD SOFFITNEW PAINTED GYP. BOARD SOFFITNEW LIBRETTO CEILING SYSTEM WITH DOWN LIGHT FIXTURES. REFER TO ELECT. LIGHTING PLANSEXISTING CEILING GRID SYSTEM TO REMAIN. REPLACE ALL ACOUSTIC CEILING TILES THROUGHOUT UNLESS NOTED OTHERWISE. MAINTAIN FIRE SPRINKLER, HVAC, AND LIGHTING LOCATIONS UNLESS NOTED OTHERWISE PERIMETER LED FIXTURE. REFER TO ELECT. LIGHTING PLANPERIMETER LED FIXTURE. REFER TO ELECT. LIGHTING PLANDOWN LIGHTING. REFER TO ELECT.ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATEDESCRIPTIONBY5 09-22-2017 ADDENDUM 55148CONFORMED SET
OSOSNEW CANOPY IN PHASE 2 -NOT PHASE ONE WORK31-BC3-A101R 2 7 ' - 0 "
R 37 ' - 0"
R 27' - 0"R 37' - 0"R 27' - 0"
R 27' - 0 "R 37' - 0"R 37' - 0"R 27' - 0"6' - 6"85' - 4"12' - 2"3' - 2"1' - 10"2' - 6"11' - 8"11' - 1"21-BC3-A105NEW STUCCO FINISH OVER 5/8" EXTERIOR SHEATHING AND 3 5/8" METAL STUDSREFER TO ELECTRICAL FOR LIGHTING LAYOUT9' - 6"12' - 9"BK.7BE6BE7TO FACE OF COLUMN± 2' - 9"VARIESREFER TO PLANPROFILE EDGELIBRETTOVARIESTO FACE OF COLUMN± 3' - 2"B.O. LIBRETTO9'-3 1/2"MAX6"LIBRETTO CEILING SYSTEMACOUSTICAL CEILING TILESOFFIT HEIGHT9' - 0"3 5/8" STUDS @ 16" O.C.DIAGONAL BRACING @ 48" O.C.3 5/8" STUDS @ 16" O.C.EXTEND GYPSUM WALL BOARD TO 6" ABOVE DROP CEILING, TYP.MAX6"3 5/8" STUDS @ 16" O.C.5/8" GYPSUM BOARD -PAINTEDCEILING HEIGHTEXISTINGCEILING HEIGHT10'-6"LIGHT FIXTURE, REFER TO ELECTRICALLIGHT FIXTURES, BEYONDEXISTING COLUMNEXISTING COLUMNDIAGONAL BRACING @ 48" O.C.500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt10/5/2017 11:05:50 AM1-BC3-A105PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREFLECTED CEILING PLAN - BAGGAGE CLAIM 3EXISTING EXTERIOR CANOPY07-14-2017S12014 1/8" = 1'-0"1REFLECTED CEILING PLAN - BAGGAGE CLAIM 3 EXTERIOR CANOPYORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTHEXISTING CEILING GRID SYSTEM TO REMAIN. REPLACE ALL ACOUSTIC CEILING TILES THROUGHOUT UNLESS NOTED OTHERWISE. MAINTAIN FIRE SPRINKLER, HVAC, AND LIGHTING LOCATIONS UNLESS NOTED OTHERWISE NEW PAINTED GYP. BOARD SOFFITNEW LIBRETTO CEILING SYSTEM WITH DOWN LIGHT FIXTURES. REFER TO ELECT.LIGHTING PLANSEXISTING CEILING GRID SYSTEM TO REMAIN. REPLACE ALL ACOUSTIC CEILING TILES THROUGHOUT UNLESS NOTED OTHERWISE. MAINTAIN FIRE SPRINKLER, HVAC, AND LIGHTING LOCATIONS UNLESS NOTED OTHERWISE PERIMETER LED FIXTURE. REFER TO ELECT. LIGHTING PLANPERIMETER LED FIXTURE. REFER TO ELECT. LIGHTING PLANDOWN LIGHTING. REFER TO ELECT.NEW LIBRETTO CEILING SYSTEM WITH DOWN LIGHT FIXTURES. REFER TO ELECT.LIGHTING PLANSDOWN LIGHTING. REFER TO ELECT. 3/4" = 1'-0"2SOFFIT/LIBRETTO CEILING DETAILREVISIONS# DATEDESCRIPTIONBY149CONFORMED SET
#136" GRAB BAR242" GRAB BAR3BABY CHANGING TABLEa. SOLID SURFACE BABY CHANGING TABLE WITH INTEGRAL 4" FRONT EDGEb. STAINLESS STEEL RECESSED BABY CHANGING STATIONc. SURFACE MOUNTED ADA CHANGING STATION4WALL/ FLOOR MOUNTED TOILET - FLUSH VALVE ON OPEN SIDE OF SPACE IN ALL ADA STALLS - REFER TO PLUMBING5TOILET PAPER DISPENSERa. RECESS MOUNTED JUMBO TISSUE DISPENSERb. RECESS MOUNTED JUMBO TISSUE DISPENSER WITH SANITARY NAPKIN DISPOSALc. NOT USEDd. NOT USEDe. PARTITION/WALL MOUNTED JUMBO DISPENSER7SANITARY NAPKIN DISPOSALa. SHARED PARTITION MOUNTEDb. PARTITION SURFACE MOUNTEDc. RECESSED8MIRRORa. 24" X 36" WALL MOUNTEDb. 24" X 48" WALL MOUNTEDc. 18" X 36" WALL MOUNTED9WALL MOUNTED URINAL10SOLID SURFACE COUNTER WITH 1 1/2" INTEGRAL FRONT EDGE. COUNTER MOUNTED AT 5'-0" AFF.11SINKS - REFER TO PLUMBING & ELECTRICAL DRAWINGSa. ADA SINGLE SOLID SURFACE TROUGH SINK WITH TOUCHLESS HANDWASHING CONTROLb. CONTINUOUS SOLID SURFACE TROUGH SINK AND 2 TOUCHLESS WASH BAR. c. CONTINUOUS SOLID SURFACE TROUGH SINK AND 3 TOUCHLESS WASH BAR. d. STANDARD ADA COMPLIANT WALL MOUNTED SINK WITH ADA FAUCET CONTROLSe. ADA COMPLIANT DROP IN SINK AND FAUCETRESTROOM LEGEND12ADA WALL MOUNTED SOAP DISPENSER13ADA WALL MOUNTED DRYERADA COMPLIANT SHOWER SEAT14SHOWER CURTAIN AND ROD15PLASTIC LAMINATE TALL CABINET1617MOP SINK WITH WALL MOUNTED MOP CLIPS18HI / LOW ADA DRINKING FOUNTAINS19WALL MOUNTED COAT HOOKS20ADA RESTROOM WALL SIGNAGE21WALL TILE - REFER TO SHEET G106 FOR FINISHa. FIELD TILEb. ACCENT TILEc. BULLNOSE TILEd. COVE BASE TILE 1. REFER TO SHEET G111 FOR ADA SPECIFICATIONS.2. ALL FIELD WALL TILE GROUT LINES TO ALIGN WITH FLOOR GROUT LINES. 3. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION.GENERAL NOTES22TOILET PARTITION23PARTITION MOUNTED COAT HOOKXX24NAPKIN/TAMPON VENDOR6PLASTIC LAMINATE COUNTER WITH 4" BACKSPLASH ON 3 SIDES. COLOR TBD.23b5c11a13123b445cFAMILY RESTROOMBC3-04FAMILY RESTROOMBC3-0311a8c13111120201-BC3-A401210' - 4"6"10' - 4"STORAGEBC3-02OFFICES / IT ROOMBC3-05CUSTOMS / FIRE PROTECTION AREACOMBINEDFP1-05BAGGAGE CLAIM 3FP1-0331-BC3-A40123BC3-03BC3-043325445ITBC3-09INSTALL NEW 72" X 62" BI FOLDING CLOSET DOOREXTEND CARPET FINISH INTO CLOSETCONCRETE FLOOR FINISHEXTEND 2X2 CEILING INTO CLOSET AND INSTALL (2) RECESSED CAN LIGHTS3A3ANEW WALL HEIGHT TO 6" ABOVE CEILINGINSTALL 1 LED 2X2 LIGHT HUNG FROM STRUCTUREEXPOSED CEILINGNEW 36"X84" SOLID WOOD CORE DOOR WITH HARDWARE SET #12PAINT WALLSEXTEND FLOOR FINISH FROM BAGGAGE CLAIM 3NEW 36"X84" SOLID WOOD CORE DOOR WITH HARDWARE SET #12 AND NEW CARD READERINSTALL NEW BULKHEAD TO ROOF DECK. BOTTOM OF BULKHEAD AT 8'-0" A.F.F.INSTALL 4 NEW 2X2 LED LIGHT FIXTURES AND REPLACE CEILING TILES IN EXISTING CORRIDOR AREAINSTALL 3 NEW POWER OUTLETS AND SWITCH FOR LIGHTINGNEW DIFFUSER NEW WALL HEIGHT TO 6" ABOVE CEILING IN CLOSET3A3A3' - 0"5"7' - 10"5"21a211a145b8c21b21d3' - 0"9' - 0"6b10"2' - 0"2' - 0"1' - 0"1' - 0"1' - 0"2' - 10"3' - 3"FLOOR LINE0"213b46b5c4' - 7"21a21dEQ8' - 0" (4 TILES @ 2'-0" EA)EQ2' - 10"FLOOR LINE0"11a138c21aBC3-0321dEQ8' - 0" (4 TILES @ 2'-0" EA)EQ2' - 10"3' - 6"FLOOR LINE0"3b10"2' - 0"2' - 0"2' - 0"1' - 0"21a21d500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 9:50:15 AM1-BC3-A401PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAENLARGED FLOOR PLAN AND INTERIORELEVATIONS- BAGGAGE CLAIM 3 RESTROOMS07-14-2017S12014ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTH 1/4" = 1'-0"1ENLARGED RESTROOM PLAN - BAGGAGE BELT 3 1/2" = 1'-0"2FAMILY RESTROOM BAGGAGE CLAIM 3.. 1/2" = 1'-0"3FAMILY RESTROOM BAGGAGE CLAIM 3. 1/2" = 1'-0"4FAMILY RESTROOM BAGGAGE CLAIM 3 1/2" = 1'-0"5FAMILY RESTROOM BAGGAGE CLAIM 3...REVISIONS# DATEDESCRIPTIONBY6 09-28-2017 ADDENDUM 66CONFORMED SET150
HVACBC3-07KITCHENBC3-06BAGGAGE CLAIM 3FP1-03OFFICES / IT ROOMBC3-05FAMILY RESTROOMBC3-04FAMILY RESTROOMBC3-03STORAGEBC3-02??CUSTOMS / FIRE PROTECTION AREACOMBINEDFP1-05BC3-07BC3-04BC3-03BC3-05BC3-0631-BC3-A101BC3-09BC3-10ITBC3-09BC3-1172" BIFOLD DOORWALL TYPE LEGENDNEW WALLEXISTING WALLDOOR TAG - REFER TO SCHEDULE#NEW MASONRY WALL7' - 0"2"7' - 2"2"3' - 0"2"3' - 4"SINGLE FLUSH HOLLOW METAL DOORDOUBLE HOLLOW METAL DOOR7' - 0"2"7' - 2"2"3' - 0"3' - 0"2"5/8" GYPSUMBOARD BOTHSIDESDOUBLE 3 5/8"METAL STUDS PER WALL TYPEHOLLOW METALFRAMESOLID CORE WOOD DOOR BATT INSULATION REFERTO WALL TYPES5/8" GYPSUM BOARD BOTH SIDES3 5/8" METAL STUDS PER WALL TYPESOLID CORE WOOD DOOR BATT INSULATION REFERTO WALL TYPESHOLLOW METAL FRAME7'-0" A.F.F.FIS-14AFIS-13FIS-14SECURITY EXITFIS-14ITFIS-13LOBBYFIS-15FIS-1522' - 2 1/2"3' - 0"11' - 10 1/2"2' - 8 1/2"25' - 0"2' - 9"1A2.0ADD SIGN TO FRONT FACE OF ALL DOORS THAT ENTER INTO SECURE AREAHEIGHT = 18"WIDTH = 18"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:33:36 AM1-BC3-A601PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADOOR SCHEDULE AND KEY PLAN - BAGGAGECLAIM 3 AND F.I.S. CUSTOMS07-14-2017S12014 1/8" = 1'-0"1DOOR SCHEDULE KEY PLAN - BAGGAGE CLAIM 3NNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANSCREENING EXPANSIONOUTBOUNDF.I.S. / CUSTOMSINBOUNDDOOR SCHEDULE - FIS SECURITY CORRIDORSAA #CARDREADERDoor # Room NameDoor SizeDoorLabelDetailsFrameHardwareSetCommentsWidth Height Thickness Door Material Door FinishHead Jamb Threshold Material FinishYES FIS-13 IT3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORESTAIN2/1-BC3-A601 3/1-BC3-A601HOLLOW METAL PAINT 12N0 FIS-14 SECURITY EXIT 6' - 0" 7' - 0" 1 3/4" ALUMINUM/GLASSALUMALUMINUM21N0 FIS-14A SECURITY EXIT 6' - 0" 7' - 0" 1 3/4" ALUMINUM/GLASSALUMALUMINUM21YES FIS-15 LOBBY3' - 0" 7' - 0" 1 3/4" ALUMINUM/GLASSALUMALUMINUM21 1/2" = 1'-0"4DOOR ELEVATIONS 3" = 1'-0"3INTERIOR DOOR JAMB 3" = 1'-0"2INTERIOR DOOR HEAD 1/8" = 1'-0"5DOOR SCHEDULE - F.I.S. CUSTOMS - SECURITY EXITNNORTHDOOR SCHEDULE - BAGGAGE CLAIM 3SAA #CARDREADERDoor # Room NameDoor SizeDoorLabelDetailsFrameHardwareSetCommentsWidth Height Thickness Door Material Door FinishHead Jamb Threshold MaterialFinishNO BC3-03 BAGGAGECLAIM 33' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN FAMILY RESTROOM 2/1-BC3-A601 3/1-BC3-A601HOLLOW METAL PAINT 19NO BC3-04 BAGGAGECLAIM 33' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN FAMILY RESTROOM 2/1-BC3-A601 3/1-BC3-A601HOLLOW METAL PAINT 19NO BC3-05 BAGGAGECLAIM 33' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN AUTHORIZEDPERSONNEL ONLY2/1-BC3-A601 3/1-BC3-A601HOLLOW METAL PAINT 20NO BC3-06 KITCHEN 3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-BC3-A601 3/1-BC3-A601HOLLOW METAL PAINT 13YES BC3-07 HVAC6' - 0" 7' - 0" 1 3/4" HOLLOW METALPAINT2/1-BC3-A601 3/1-BC3-A601HOLLOW METAL PAINT 18NO BC3-08 BLOCKHOUSE 6' - 0" 7' - 0"1 3/4" HOLLOW METALPAINT AUTHORIZEDPERSONNEL ONLY1/3-SW-A603SIM2/3-SW-A603SIM3/3-SW-A603 SIM HOLLOW METAL PAINT 16NO BC3-09 IT3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORESTAIN2/1-BC3-A601 3/1-BC3-A601HOLLOW METAL PAINT 12YES BC3-10 CUSTOMS 3' - 0" 7' - 0" 1 3/4" SOLID WOOD CORE STAIN2/1-BC3-A601 3/1-BC3-A601HOLLOW METAL PAINT 13NO BC3-11 BAGGAGECLAIM 318' - 0" 10' - 0" 1 3/4" STEELPREFINISHEDSTEELPREFINISHED4 HOUR FIRE DOORGENERAL NOTE: IF DOOR DOES NOT HAVE A CARD READER THEN IT WILL REQUIRE A LOCK AND KEY. KEYING WILL REQUIRE COORDINATION WITH S.A.A.DOOR SCHEDULE - FIRE RISERSAA #CARDREADERDoor # Room NameDoor SizeDoorLabelDetailsFrameHardwareSetCommentsWidth Height Thickness Door Material Door FinishHead Jamb Threshold Material FinishNO FP-06 FIRE RISER ROOM 6' - 0" 7' - 0" 1 3/4"SOLID WOOD CORE STAIN 2/1-BC3-A601 3/1-BC3-A601 HOLLOW METAL PAINT 18 SIM SEE SHEET 1-BC3-A102 FOR DOORREVISIONS# DATEDESCRIPTIONBY4 09-08-2017 ADDENDUM 46 09-28-2017 ADDENDUM 666CONFORMED SET151
4' - 0"13' - 1"2' - 4 3/4"1' - 1 3/8"TILE START POINT10"51' - 5 1/2"25' - 2 1/2"2' - 3"EXISTING METAL GATE THRESHOLDBAGGAGE CLAIM 3FP1-03OFFICES / IT ROOMBC3-05FAMILY RESTROOMBC3-04FAMILY RESTROOMBC3-03STORAGEBC3-02??KITCHENBC3-06HVACBC3-07R 10' - 4"R 14' - 3 1/8"5' - 5"13' - 6 1/2"31-BC3-A101TZ1TZ2TZ3C1T1T1R 14' - 7 5/8"EQ15' - 5"EQ4' - 0"25' - 3"FIRE RISER ROOMFP-06ALL FINISHES THIS ROOM TO MATCH EXISTING ADJACENT FINISH.UPDATE ALL ELEVATOR FINISHES TO MATCH NEW ELEVATOR. PROVIDE CARPET FLOORING. REFER TO SHEET 1-NIE-A703.C1C1FINISH LEGENDCARPETCARPET ACCENTCARPET ACCENTVCTTILE FLOORINGTERRAZZO TILETERRAZZO TILE ACCENTTERRAZZO TILE ACCENTCHILDREN PLAY AREAFLOORINGSEALED CONCRETERECESSED WALK-OFF MATMILLWORKGENERAL NOTES1. REFER TO ELEVATIONS FOR LOCATION OF ADDITIONAL WALL SURFACE FINISH.2. REFER TO CEILING PLANS FOR CEILING FINISH LOCATION.3. REFER TO GENERAL SHEET G-106 FOR FINISHES.4. ALL FLOOR FINISHES EXTEND TO ADJACENT WALLFLOOR TILE INSTALLATION NOTES1. ALL CONCRETE FLOORS MUST BE TESTED FOR MOISTURE AND PH PRIOR TO INSTALLATION.2. REFER TO SPECIFICATIONS FOR MOISTURE AND PH LEVEL TOLERANCES.3. SUBSTRATE MUST BE FLAT WITHIN THE EQUIVALENT OF 1/8" IN 10'-0".4. SUBSTRATE MUST BE FREE OF ADHESIVE, SEALERS, PAINT, COATINGS, FINISHES, DIRT, FILM FORMING CURING COMPOUNDS, OR OTHER SUBSTANCES THAT MAY AFFECT THE ADHESION OF THE FLOORING.5. DO NOT INSTALL FLOOR TILE BEFORE ALL OTHER TRADES ARE FINISHED.6. ALL MATERIALS MUST BE ON SITE IN THE ROOM WHERE THEY WILL BE INSTALLED 48 HOURS BEFORE INSTALLATION. TILE MUST BE STORED BEHIND TEMPORARY CONSTRUCTION WALL.7. CLOSE SPACES TO TRAFFIC 12 HOURS BEFORE INSTALLATION AND 24 HOURS AFTER INSTALLATION IS COMPLETE.5. PAINT ALL JOIST AND EXPOSED SURFACES ABOVE WITH DRY FALL PAINT500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt9/29/2017 10:35:07 AM1-BC3-A701PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFINISH PLAN AND SCHEDULE - BAGGAGE CLAIM 307-14-2017S12014 1/8" = 1'-0"1FINISH PLAN - TERMINAL ADDITION WEST 1ST FLOORORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDNNORTHFINISH SCHEDULE - BAGGAGE CLAIM 3RM. NO. ROOM NAME AreaFLOORBASEWALL FINISHESCEILINGNOTESNorth Finish East Finish South Finish West FinishBC3-01 STORAGE138 SFCONCRETEVINYL - B3 PAINTPAINTPAINTPAINTEXPOSEDBC3-02 STORAGE83 SFCONCRETEVINYL - B3 PAINTPAINTPAINTPAINTEXPOSEDBC3-03 FAMILY RESTROOM 80 SFPORCELAIN TILETILE - T8 TILETILETILETILEGYP. BD. PAINTBC3-04 FAMILY RESTROOM 80 SFPORCELAIN TILETILE - T8 TILETILETILETILEGYP. BD. PAINTBC3-05 OFFICES / IT ROOM 239 SFCARPETVINYL - B3 PAINTPAINTPAINTPAINTCEILING TILESBC3-06 KITCHEN1056 SFN/AN/A N/AN/AN/AN/AN/ABC3-07 HVAC603 SFCONCRETEVINYL - B3 PAINTPAINTPAINTPAINTCEILING TILESFP-06 FIRE RISER ROOM 37 SF EXISTING FLOOR TO REMAIN VINYL PAINT PAINT PAINT PAINT EXISTINGNOTE: ALL COLUMNS IN PUBLIC SPACE TO RECEIVE MARLITE SYSTEM AND PAINT. REFER TO DETAILS 6 AND 7 ON SHEET G116 UNLESS NOTED OTHERWISE. PROVIDE BOX EXTENSIONS FOR ALL ELECTRICAL AND COMMUNICATIONS OUTLETS AS NECESSARY, REFER TO MEP DRAWINGS.REVISIONS# DATEDESCRIPTIONBY6 09-28-2017 ADDENDUM 66CONFORMED SET152
WFEXISTING ELEVATOREXISTING STAIRSEXISTING ESCALATORSECURITY EXITBADGE DOOR ACCESSSTAIRSNEW METAL STUD WALL5"13' - 0"3A53A3AITFIS-13SECURITY EXITFIS-14BAGGAGE CLAIMFIS-031-FIS-A71131-FIS-A71121-FIS-A711122' - 2 1/2"3' - 0"11' - 10 1/2"2' - 8 1/2"25' - 0"2' - 9"4' - 4 1/2"6' - 0"8' - 9 1/4"3A53A3AFLOOR PLAN LEGEND:NEW WALLEXISTING WALLDOOR TAG FOR NEW DOORS1i101AFLOOR ELEVATIONWALL TYPE TAGREFER TO 1-G-A501 & 1-G-A502EXISTING CEILING TO REMAINEXISTING CEILING TO REMAINSECURITY EXITFIS-14ITFIS-13BAGGAGE CLAIMFIS-03LOBBYFIS-1530"X30" CEILING ACCESS PANELNEW GYPSUM BOARD CEILINGNEW 2X2 CEILING PANEL SYSTEMEXPOSED CEILINGINTERIOR WALL HEIGHT LEGENDFULL HEIGHT WALL ATTACHED TO DECKWALL TO EXTEND TO 6" ABOVE FINISHED CEILING - BRACE TO STRUCTURE ABOVEC1C1LOBBYFIS-15SECURITY EXITFIS-14ITFIS-13500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:43:26 PM1-FIS-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFLOOR PLAN - F.I.S. CUSTOMS - SECURITY EXIT07-14-2017S12014 1/8" = 1'-0"1FLOOR PLAN - F.I.S. CUSTOMS - SECURITY EXITNNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDREVISIONS# DATE DESCRIPTION BY 1/8" = 1'-0"2REFLECTED CEILING PLAN - F.I.S 1/8" = 1'-0"3FLOOR FINISH PLAN - F.I.S.CUSTOMS - SECURITY EXITFINISH SCHEDULE - FIS SECURITY CORRIDORRM. NO.ROOM NAMEAreaFLOOR BASEWALL FINISHESCEILINGNOTESNorthFinishEast FinishSouthFinishWest FinishFIS-13 IT95 SF CONCRETE VINYL PAINT PAINT PAINT PAINTEXPOSEDFIS-14 SECURITY EXIT565 SFCARPET VINYL - B3 GLASS GLASS GLASS PAINT GYP. BD. PAINTFIS-15 LOBBY499 SFCARPET VINYL - B3 PAINT GLASS GLASS/PAINTPAINT CEILING TILESCONFORMED SET153
KAWNEER 350 STOREFRONT DOORMETAL STUD WALL -FINISH WITH 5/8" GYPSUM WALL BOARD AND PAINT -TYP7' - 0"1' - 6"KAWNEER TRI FAB 451 OR ARCHITECT APPROVED EQUAL6' - 0"25' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"EXISTING RAMP6' - 5"4' - 2"KAWNEER 350 STOREFRONT DOORMETAL STUD WALL -FINISH WITH 5/8" GYPSUM WALL BOARD AND PAINT -TYP1' - 6"7' - 0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/2" = 1'-0"C:\Users\lmurrah\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_lmurrah.rvt7/15/2017 1:43:43 PM1-FIS-A711PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAINTERIOR ELEVATIONS - F.I.S. CUSTOMS -SECURITY EXIT07-14-2017S12014REVISIONS# DATE DESCRIPTION BY 1/2" = 1'-0"1INTERIOR STOREFRONT ELEVATION 1/2" = 1'-0"2INTERIOR STOREFRONT ELEVATION 1/2" = 1'-0"3INTERIOR STOREFRONT ELEVATIONORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDF.I.S. SECURITY EXITCONFORMED SET154
4' - 0"12' - 6"4' - 0"12' - 6"4' - 3"123456AB1' - 0"15' - 6"1' - 0"16' - 3"1' - 0"1' - 0"11-SPL-A30121-SPL-A3011-SPL-A20141-SPL-A2011-SPL-A2011-SPL-A20112310X6 PRE-FINISHED ALUMINUM COLUMNS - TYPICAL @ (8) LOCATIONS CONTROL GATE -CONTRACTOR TO COORDINATE EXACT LOCATION WITH SHOP DRAWINGSTICKET PEDESTAL -CONTRACTOR TO COORDINATE EXACT LOCATION WITH SHOP DRAWINGS6" DIA. STEEL BOLLARD6" DIA. STEEL BOLLARDCONCRETE ISLAND - REFER TO CIVILCONCRETE ISLAND - REFER TO CIVILCURB - REFER TO CIVILASPHALTCONCRETEASPHALTCONCRETESLOPESLOPESLOPESLOPE47'-0"TOP OF SLAB47'-0"TOP OF SLAB47'-0"TOP OF SLAB47'-0"TOP OF SLAB47'-2"TOP OF SLAB47'-8"TOP OF CURBSLOPESLOPE47'-2"TOP OF SLAB47'-0"TOP OF SLAB47'-0"TOP OF SLAB47'-8"TOP OF CURB47'-8"TOP OF CURB47'-8"TOP OF CURB6" CONCRETE SLAB6" CONCRETE SLAB6" CONCRETE SLABCOLUMN WITH INTERNAL DRAINAGECOLUMN WITH INTERNAL DRAINAGECOLUMN WITH INTERNAL DRAINAGECOLUMN WITH INTERNAL DRAINAGEROOF LINE ABOVEROOF LINE ABOVEROOF LINE ABOVE26' - 9 1/2"1' - 0"4"1' - 0"4"1' - 0"1' - 0"4"4"4"4"1' - 0"1' - 0"1' - 0"1' - 0"4"4"1' - 4"6"TICKET PEDESTAL -CONTRACTOR TO COORDINATE EXACT LOCATION WITH SHOP DRAWINGSCONTROL GATE -CONTRACTOR TO COORDINATE EXACT LOCATION WITH SHOP DRAWINGS35' - 3"6"1' - 4"6" DIA. STEEL BOLLARDCONCRETE ISLAND - REFER TO CIVIL30' - 0"500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/2" = 1'-0"C:\Users\lmurrah\Documents\PARKING CONTROL GATE_detached_lmurrah.rvt7/15/2017 2:12:36 PM1-SPL-A101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACANOPY FLOOR PLAN07-14-2017S12014 1/2" = 1'-0"1PARKING CANOPYNPLANNORTHNOTE: ELEVATION REFERENCE 47'-0" IS EQUAL TO ARCHITECTURAL ELEVATION 0'-0" ON SHEETS A2.0 AND A3.0ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDSOUTH PARKING LOTREVISIONS# DATE DESCRIPTION BYCONFORMED SET155
35' - 3"25' - 8"123456AB11-SPL-A30121-SPL-A3011-SPL-A20141-SPL-A2011-SPL-A201131-SPL-A30171-SPL-A30184 1/2" PRE-FINISHED ALUMINUM METAL DECKINGPRE-FINISHED ALUMINUM METAL GUTTERPRE-FINISHED ALUMINUM METAL GUTTERPRE-FINISHED ALUMINUM METAL GUTTER4 1/2" PRE-FINISHED ALUMINUM METAL DECKINGSLOPE 6:12SLOPE 6:12SLOPE 6:12SLOPE 6:12RIDGERIDGERIDGERIDGERIDGECOLUMN WITH INTERNAL DRAINAGE COLUMN WITH INTERNAL DRAINAGE COLUMN WITH INTERNAL DRAINAGE COLUMN WITH INTERNAL DRAINAGE 61-SPL-A30161-SPL-A30141-SPL-A30141-SPL-A301500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/2" = 1'-0"C:\Users\lmurrah\Documents\PARKING CONTROL GATE_detached_lmurrah.rvt7/15/2017 2:12:47 PM1-SPL-A102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACANOPY ROOF PLAN07-14-2017S12014 1/2" = 1'-0"1CANOPY ROOF PLANNPLANNORTHORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDSOUTH PARKING LOTREVISIONS# DATE DESCRIPTION BYCONFORMED SET156
TOP OF SLAB0"ABBEAM CLEAR14' - 0"RIDGE HEIGHT21' - 9"61210X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGE4 1/2" PRE-FINISHED ALUMINUM DECKING6" DIA. STEEL BOLLARD6" DIA. STEEL BOLLARD10X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGE4' - 0"UNDER CANOPY SURFACE MOUNTED LIGHTINGUNDER CANOPY SURFACE MOUNTED LIGHTINGTOP OF SLAB0"123456BEAM CLEAR14' - 0"5/8" THICK (3) COAT SMOOTH FINISH STUCCOPRE-CAST WALL COPING10X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGE4 1/2" PRE-FINISHED ALUMINUM DECKING612612RIDGE HEIGHT21' - 9"PARKING CONTROL GATESCURBPRE-FINISHED ALUMINUM GUTTER10X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGEPARKING CONTROL GATESCURBCURB4 1/2" PRE-FINISHED ALUMINUM DECKINGCONTROL SIGNAGEINTERNAL DRAINAGE COLUMN KEYHOLE4' - 0"6" DIA. BOLLARDS @ 48" ABOVE CURB - TYPINTERNAL DRAINAGE COLUMN KEYHOLETOP OF SLAB0"ABBEAM CLEAR14' - 0"RIDGE HEIGHT21' - 9"61210X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGEPARKING CONTROL GATESCURB4 1/2" PRE-FINISHED ALUMINUM DECKING6" DIA. STEEL BOLLARD6" DIA. STEEL BOLLARD10X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGEUNDER CANOPY SURFACE MOUNTED LIGHTINGUNDER CANOPY SURFACE MOUNTED LIGHTINGTOP OF SLAB0"123456BEAM CLEAR14' - 0"RIDGE HEIGHT21' - 9"10X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGE4 1/2" PRE-FINISHED ALUMINUM DECKING612612PARKING CONTROL GATESCURBPRE-FINISHED ALUMINUM GUTTER10X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGEPARKING CONTROL GATESCURBCURB4 1/2" PRE-FINISHED ALUMINUM DECKINGCONTROL SIGNAGEINTERNAL DRAINAGE COLUMN KEYHOLE500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E Firm 1/4" = 1'-0"C:\Users\lmurrah\Documents\PARKING CONTROL GATE_detached_lmurrah.rvt7/15/2017 2:12:56 PM1-SPL-A201PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACANOPY ELEVATIONS07-14-2017S12014 1/4" = 1'-0"4SOUTH ELEVATION 1/4" = 1'-0"1EAST ELEVATION 1/4" = 1'-0"2NORTH ELEVATION 1/4" = 1'-0"3WEST ELEVATIONORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANOUTBOUNDF.I.S. / CUSTOMSINBOUNDSOUTH PARKING LOTREVISIONS# DATE DESCRIPTION BYCONFORMED SET157
TOP OF SLAB0"123456BEAM CLEAR14' - 0"RIDGE HEIGHT21' - 9"1-SPL-A301610X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGE4 1/2" PRE-FINISHED ALUMINUM DECKING612612PARKING CONTROL GATESCURBPRE-FINISHED ALUMINUM GUTTER10X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGEPARKING CONTROL GATESCURBCURB4 1/2" PRE-FINISHED ALUMINUM DECKING10X6 PRE-FINISHED ALUMINUM BEAMADD "BIRD SPIKES" THROUGHOUT ALL EXPOSED BEAMS ON UNDERCARRIAGE OF CANOPY SYSTEMCONTROL SIGNAGEUNDER CANOPY SURFACE MOUNTED LIGHTINGUNDER CANOPY SURFACE MOUNTED LIGHTINGUNDER CANOPY SURFACE MOUNTED LIGHTINGTOP OF SLAB0"ABBEAM CLEAR14' - 0"RIDGE HEIGHT21' - 9"1-SPL-A30131-SPL-A301461210X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGEPARKING CONTROL GATESCURB4 1/2" PRE-FINISHED ALUMINUM DECKING6" DIA. STEEL BOLLARD6" DIA. STEEL BOLLARD10X6 PRE-FINISHED ALUMINUM COLUMN WITH INTERNAL DRAINAGEADD "BIRD SPIKES" THROUGHOUT ALL EXPOSED BEAMS ON UNDERCARRIAGE OF CANOPY SYSTEMCONTROL SIGNAGEUNDER CANOPY SURFACE MOUNTED LIGHTINGUNDER CANOPY SURFACE MOUNTED LIGHTING6124 1/2" DECKCUSTOM 1/8" ANGLE10 X 6 RIDGE BEAMSCREW, 14B x 3/4" SS W/NEOPRENE WASHERAT EACH DECK BOTTOM.040 RIDGE CAP6 X 6 BEAM6 X 6 TUBE4 1/2" DECK6 X 6 BEAMI.B.P. W/ 4- 1/2" SS FASTENERSSIM. 3" DECK1'-0"1'-0"WATERWATERWATER6 X 6 BEAM10 X 6 TUBEWELDED CONNECTION10 X 6 COLUMN6" GUTTERSCUPPER6" FASCIACUSTOM 1/8" ANGLETO 10 X 6 TUBEBOLTED TO 10 X 6 COL.4 1/2" DECKFASCIA TIE BACK STRAP10 X 6 RIDGE BEAM6 X 6 BEAMCUSTOM 1/8" ANGLE4 1/2" DECKSIM. 3" DECKWATERWATERWATER10 X 6 TUBE10 X 6 COLUMN6" GUTTERSCUPPER6" FASCIACUSTOM 1/8" ANGLEBOLTED TO 10 X 6 COL.10 X 6 BEAM3/8" X 1'-2" X 10"PLATE WELDED TO HIP BEAM4 1/2" DECKFASCIA TIE BACK STRAP10 X 6 TUBEBOLTED TO 10 X 6 COL.10 X 6 COLUMN 4- SS FASTENERSCONNECTED TO 10 X 6 COL.DRILL AND TAP6" GUTTERSCUPPER10 X 6 HIP BEAM1/4" IBP W/ 2- 1/2" SS FASTENERS10 X 6 BEAM10 X 6 BEAM10 X 6 BEAM500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:JOHN A. BAER, AIADrawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJABLDMJABJABwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic / TransportationOffices in:•Florida•Puerto Rico•Connecticut•Maryland•TexasA Full ServiceA & E FirmAs indicatedC:\Users\lmurrah\Documents\PARKING CONTROL GATE_detached_lmurrah.rvt7/15/2017 2:13:07 PM1-SPL-A301PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACANOPY SECTIONS07-14-2017S12014 1/4" = 1'-0"1SECTION 1/4" = 1'-0"2SECTION 1 1/2" = 1'-0"3RIDGE DETAIL 1 1/2" = 1'-0"4EAVE DETAIL 1 1/2" = 1'-0"5RIDGE BEAM DETAIL 1 1/2" = 1'-0"6EAVE DETAIL 2 1 1/2" = 1'-0"8CORNER DETAIL 1 1/2" = 1'-0"7BEAM CONNECTION DETAILREVISIONS# DATE DESCRIPTION BYCONFORMED SET158
11-S001 1-S30111-S001 1-S10113' - 0"UNKREST
R
I
C
T
E
D
AREAKEEPOUTGENE
R
A
T
O
R
11-S001 1-S10311-S001 1-S50111-S001 1-S50221-S001 1-S10321-S001 1-S30121-S001 1-S10511-S001 1-S106 1/64" = 1'-0"12/19/2015 12:06:59 PM1-S001ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE FIRST FLOOR PLAN - STRUCTURALSCOPE OF WORK07-14-2017S12014REVISIONS# DATEDESCRIPTIONBY 1/64" = 1'-0"PHASE I: COMPOSITE PLAN FIRST FLOOR PLAN - STRUCTURAL SCOPE OF WORKNNORTHJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S001.dwg Jul 12, 2017 - 2:29pm daranCONFORMED SET159
RESTR
I
C
T
ED
AREAKEEPOUT11-S002 1-S30211-S002 1-S20121-S002 1-S302
Table
Table
Table
Table
Table Table
Table
Table TDC #1 TDC #2TDC #3 TDC #4TDC #5 TDC #6TDC #7TDC #8TDC/CA
T
TDC/C
A
T
TDC/CA
T
TDC/C
A
T
TDC/CAT
TDC/CA
T
TDC/CA
T
TDC/C
A
T
BLSETD
AVS
AVS
AVS
BLSETD
AVS
AVS
BLSETDAVSAVS
BLSETDBLSETDAVS
2ADAGATELCEIAWTMD1
2ETD
ETDETDETD
L
L4
3L43L3L32
ADAGATE
LCEIAWTMD1
2ADAGATELCEIAWTMD12ADAGATELCEIAWTMD1
[FL-343][HW-54_]ALTERNATE COUNTERFLASHURETHANE SEALANT
@ 24" O.C.TRI-BEAD TAPE SEALER[HW-504]
RIGID INSULATION(NOT BY MBCI)RAKE ANGLE2" x 4" x 14 GA.@ 24" O.C. (PRE-DRILL ANGLE)@ 24" O.C.[HW-7500][HW-230][FL-291][HW-504][FL-285](2 PER CLIP)14-13 x ___ DECKSCREW [FASTENER #15_]BEND UP 2")(FIELD CUT ANDSUPERLOK PANEL (NOT BY MBCI)VAPOR BARRIER(MIN. 22 GA. THICKNESS)(NOT BY MBCI)METAL DECK
STRUCTURAL ANGLEWOOD BLOCKING(CENTER IN SLOT)(NOT BY MBCI)(NOT BY MBCI)[HW-7712]@ 24" O.C.
PARAPETWALL
PARAPET RAKE FLASHINGTRI-BEAD TAPE SEALERLOW RAKE SUPPORT ANGLEPARAPET RAKE CLEATBEARING PLATELOW FLOATING CLIP3/8"
BUILDING DIM.(MIN.)2"18"
[FASTENER #1E]SELF-DRILLER W/WASHER1/4-14 x 1 1/4 LONG-LIFE[FASTENER #5]TEK 2 SELF-DRILLER1/4-14 x 1 1/4 SHOULDERSELF-TAPPER [FASTENER #13]10-12 x 1 PANCAKE HEAD
ANCHOR [FASTENER #11]1/4 x 1 1/4 MASONRY
EMPTYBINSEMPTYBINS
EMPTYBINSEMPTYBINS
EMPTYBINSEMPTYBINS6040aTiXAT260" DIVESTTABLE 60" DIVESTTABLE
EMPTYBINS
EMPTYBINSEMPTYBINS
EMPTYBINS 6040aTiX
AT260" DIVESTTABLE 60" DIVESTTABLEEXITENTERL3
EMPTYBINSEMPTYBINS
EMPTYBINSEMPTYBINS
EMPTYBINSEMPTYBINS6040aTiXAT260" DIVESTTABLE 60" DIVESTTABLE
EMPTYBINS
EMPTYBINSEMPTYBINSEMPTYBINS6040aTiXAT260" DIVESTTABLE 60" DIVESTTABLE
EXIT ENTERL3
EMPTYBINSEMPTYBINS
EMPTYBINSEMPTYBINS
EMPTYBINSEMPTYBINS6040aTiXAT260" DIVESTTABLE 60" DIVESTTABLE
EMPTYBINS
EMPTYBINSEMPTYBINS
EMPTYBINS 6040aTiXAT2 60" DIVESTTABLE 60" DIVESTTABLEEXITENTERL3
EMPTYBINSEMPTYBINS
EMPTYBINSEMPTYBINS
EMPTYBINSEMPTYBINS6040aTiXAT260" DIVESTTABLE 60" DIVESTTABLE
EMPTYBINS
EMPTYBINSEMPTYBINS
EMPTYBINS 6040aTiXAT2 60" DIVESTTABLE 60" DIVESTTABLEEXITENTERL3
11-S001 1-S20331-S001 1-S203 1/64" = 1'-0"12/19/2015 12:07:22 PMORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE SECOND FLOOR PLAN - STRUCTURALSCOPE OF WORKS12014REVISIONS# DATEDESCRIPTIONBY 1/64" = 1'-0"PHASE I: COMPOSITE SECOND FLOOR PLAN - STRUCTURAL SCOPE OF WORKNNORTHJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S002.dwg Jul 12, 2017 - 2:29pm daran1-S00207-14-2017CONFORMED SET160
JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S003.dwg Jul 12, 2017 - 2:30pm eavilesS120141/4" =1'-0"ABBREVIATIONS AND STRUCTURAL NOTES1-S003GENERAL STRUCTURAL NOTESTHE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THEBUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TODETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OFTHE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THEADDITION OF ANY NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS,NEEDLING OR TIE DOWNS. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'SPROPERTY AFTER COMPLETION OF THE PROJECT.CONSTRUCTION LOADS SHALL NOT EXCEED DESIGN LIVE LOADS. THE CONTRACTORSHALL BE RESPONSIBLE FOR ALL DESIGN REQUIRED TO SUPPORT CONSTRUCTIONLOADS AND EQUIPMENT USED FOR THE PROJECT.IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENFORCE ALL APPLICABLE SAFETYCODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION.THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL EXISTING CONSTRUCTIONTO REMAIN, IF ANY. ANY DAMAGE CAUSED BY THE CONTRACTOR SHALL BE REPAIREDOR REPLACED TO THE SATISFACTION OF THE OWNER AND ARCHITECT AT NO COST TOOWNER.SEE ARCHITECTURAL DRAWINGS FOR THE FOLLOWING: A) SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS, EXCEPT AS NOTED. B) SIZE AND LOCATION OF ALL INTERIOR AND EXTERIOR NON-BEARING PARTITIONS. C) SIZE AND LOCATION OF ALL CONCRETE CURBS, EQUIPMENT PADS, PITS, FLOOR DRAINS, SLOPES, DEPRESSED AREAS, CHANGE IN LEVEL, CHAMFERS, GROOVES, INSERTS, ETC. D) SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS EXCEPT AS SHOWN. E) FLOOR AND ROOF FINISHES. F) DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS.SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR THE FOLLOWING: A) PIPE RUNS, SLEEVES, HANGERS, TRENCHES, WALL AND SLAB OPENINGS, ETC., EXCEPT AS SHOWN OR NOTED. B) ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALLS AND SLABS. C) CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL, OR PLUMBING FIXTURES. D) SIZE AND LOCATION OF MACHINE OR EQUIPMENT BASES, ANCHOR BOLTS FOR MOTOR MOUNTS.ATTACHMENT OF ALL MECHANICAL EQUIPMENT TO THE STRUCTURE, INCLUDING, BUTNOT LIMITED TO HVAC ROOFTOP UNITS, ROOFTOP UNIT CURBS, ETC. ARE THERESPONSIBILITY OF THE MECHANICAL ENGINEER AND MECHANICAL CONTRACTOR.EXPANSION BOLTING:UNLESS NOTED OTHERWISE ON PLANS OR IN SECTIONS, ALL EXPANSION BOLTS INCONCRETE SHALL BE "HILTI KWIK BOLT 3 EXPANSION ANCHORS". ANCHORS USED INEXTERIOR APPLICATIONS SHALL BE HOT-DIP GALVANIZED CARBON STEEL OR STAINLESSSTEEL.EPOXY ANCHORING:UNLESS NOTED OTHERWISE ON PLANS OR IN SECTIONS, ALL EPOXY ANCHORS FOR USEIN APPLICATIONS INVOLVING MASONRY SHALL BE EITHER: A) HILTI HIT HY 70 ADHESIVE ANCHORING SYSTEM. B) SIMPSON STRONG-TIE AT HIGH STRENGTH ACRYLIC-TIE ANCHORING ADHESIVE.EPOXY ANCHORS NOTED ABOVE SHALL BE INSTALLED USING MESH SLEEVES, IFREQUIRED, PROVIDED BY THE MANUFACTURER FOLLOWING MANUFACTURERSINSTRUCTIONS.UNLESS NOTED OTHERWISE ON PLANS OR IN SECTIONS, ALL EPOXY ANCHORS FOR USEIN APPLICATIONS INVOLVING CONCRETE SHALL USE EITHER: A) HILTI HIT HY 200 ADHESIVE ANCHORING SYSTEM. B) SIMPSON STRONG-TIE AT HIGH STRENGTH ACRYLIC-TIE ANCHORING ADHESIVE.IN ALL CASES, ALTERNATE ANCHORS MAY BE CONSIDERED WITH PRIOR APPROVALFROM THE STRUCTURAL ENGINEER.INSTALL ALL ANCHORS FOLLOWING MANUFACTURER'S INSTALLATION INSTRUCTIONS.INSPECTION:AN APPROVED INDEPENDENT TESTING LABORATORY SHALL PROVIDE INSPECTIONAND TESTING SERVICES PER ASTM E329. REPORTS SHALL BE SENT DIRECTLY TO THEOWNER, ARCHITECT, STRUCTURAL ENGINEER AND CONTRACTOR. CONCRETE TESTREPORTS SHALL ALSO BE SENT TO THE READY MIX SUPPLIER. SUCH SERVICES SHALLINCLUDE:FOUNDATIONS: BEARING SURFACE.CONCRETE: DESIGN MIX DATA, DAILY POUR REPORTS, CYLINDER TESTS, ENTRAINED AIR TESTS AND TEMPERATURE. RECORD AND REPORT SLUMP FOR EACH TRUCK BEFORE AND AFTER ADDITION OF HRWR.REINFORCEMENT: PLACEMENT, TYPE, SIZE AND GRADE OF STEEL.STRUCTURAL STEEL: PLACEMENT AND CONNECTION.MASONRY: MORTAR CUBES, MASONRY PRISMS, SIZE AND LOCATION OF PIERS, USE OF PROPER MASONRY UNITS, REINFORCING PLACEMENT AND GROUTING OPERATIONS.EARTH FILL: CERTIFICATION OF ALL FILL MATERIAL AND IN-PLACE DENSITY TESTS.SPECIAL INSPECTIONS:PROVIDE SPECIAL INSPECTIONS PER CHAPTER 17 OF FBC.SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY A CITY INSPECTOR.SPECIALLY INSPECTED WORK WHICH IS INSTALLED OR COVERED WITHOUT THEAPPROVAL OF THE CITY INSPECTOR IS SUBJECT TO REMOVAL OR EXPOSURE.CONTINUOUS INSPECTION IS ALWAYS REQUIRED DURING THE PERFORMANCE OF THEWORK UNLESS OTHERWISE SPECIFIED.THE SPECIAL INSPECTORS MUST BE CERTIFIED BY THE CITY TO PERFORM THE TYPESOF INSPECTION SPECIFIED.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INFORM THE SPECIAL INSPECTOROR INSPECTION AGENCY AT LEAST ONE WORKING DAY PRIOR TO PERFORMING ANYWORK THAT REQUIRES SPECIAL INSPECTION.ALL WORK PERFORMED WITHOUT REQUIRED SPECIAL INSPECTION IS SUBJECT TOREMOVAL.SUBMIT WRITTEN REPORTS WITHIN TWO DAYS OF TESTING TO ENGINEER OF RECORD.FABRICATION AND PLACEMENT SUBMITTALS:DURING THE BIDDING PERIOD, PROMPTLY NOTIFY ARCHITECT IN WRITING IF, IN THECONTRACTOR'S OPINION, ANY PORTION OF THE WORK, INCLUDING CONNECTIONS ANDSPLICING OF MEMBERS, IS NOT CLEARLY INDICATED IN THE CONTRACT DOCUMENTS, ORIF THE DESIGN INTENT OF INDIVIDUAL MEMBERS, CONNECTIONS, AND THE STABILITY OFTHE STRUCTURE AS A WHOLE ARE NOT CLEARLY UNDERSTOOD FROM THE DOCUMENTS.SHOP DRAWINGS SHALL BE CHECKED AND COORDINATED WITH OTHER MATERIALS ANDCONTRACTS BY THE GENERAL CONTACTOR AND BEAR CHECKER'S INITIALS BEFOREBEING SUBMITTED TO THE ARCHITECT FOR APPROVAL.SHOP DRAWINGS ARE THEN TO BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TOENGINEERS REVIEW.DOCUMENTS WILL SUBMITTED TO THE ENGINEER FOR REVIEW OF CONFORMANCE WITHTHE PLANS AND SPECIFICATIONS AT LEAST 21 DAYS BEFORE REQUIRED FOR ORDERINGOR INSTALLATION AT THE JOB SITE.STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR CONSTRUCTION DELAYS DUE TOINADEQUATE SCHEDULING OF SHOP DRAWING REVIEW.THE STRUCTURAL SHOP DRAWING REVIEW IS INTENDED TO HELP THE ENGINEER VERIFYHIS DESIGN CONCEPT.THE ENGINEER WILL REVIEW THE SHOP DRAWINGS FOR GENERAL DIMENSIONS ANDELEVATIONS, MEMBER SIZES, AND STRENGTH OF CONNECTIONS.PROPRIETARY PRODUCTS REQUIRE PHYSICAL PROPERTIES OF MATERIAL AND ANYPREPARATIONS FOR INSTALLATION OR APPLICATION METHODS.CUSTOM FABRICATED ITEMS REQUIRE FABRICATION AND PLACEMENT DRAWINGSOF ALL MATERIALS. THESE DRAWINGS MUST INCLUDE PLANS AND DETAILS OF DECKMATERIAL WITH ANY INSTALLATION SEQUENCE; LOCATION OF JOINTS; FASTENINGTYPE AND SPACING; AND PROPERTIES OF MATERIALS.DESIGN CALCULATIONS ARE NECESSARY FOR ALL STRUCTURAL MEMBERS WITHDETAILS, LOCATIONS, AND LOADS ON ANY CONNECTIONS TO OTHER BUILDINGMATERIALS.AIR CONDITIONING, PLUMBING, AND OPERATING EQUIPMENT REQUIRE THELOCATIONS OF ANY OPENINGS AND CONNECTION METHODS TO ANY STRUCTURALPARTS OF THE BUILDING.IF THE FABRICATOR HAS BEEN AUTHORIZED TO USE THE ARCHITECTURAL AND/ORSTRUCTURAL ENGINEER'S DRAWINGS AS ERECTION DRAWINGS, THE FABRICATORMUST REMOVE ALL TITLE BLOCKS, PROFESSIONAL SEALS, LOGOS AND ANY OTHERREFERENCES TO THE ARCHITECT AND ENGINEER FROM THAT ERECTION DRAWING.THE FABRICATOR'S NAME AND TITLE SHALL BE PLACED ON THE DRAWINGS.ANY SUBMITTAL OF A DETAIL SHEET WITH ADDED INFORMATION SHALL BEACCOMPANIED BY LOCATION PLAN IDENTIFYING THE MEMBERS INVOLVED ANDCLOUDING AROUND ADDED INFORMATION.ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEWSHALL BE BY A REGISTERED STRUCTURAL ENGINEER, AND SUBMITTAL SHALL BESEALED BY THE ENGINEER. THE ENGINEER MUST BE REGISTERED WITH THE STATETHE PROJECT IS LOCATED WITHIN.CHANGES AND MODIFICATIONS:SUBMIT WRITTEN REQUEST TO THE ARCHITECT FOR APPROVAL OF ANY PROPOSEDCHANGE TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.SPLICING, CUTTING, NOTCHING AND OTHER ALTERATIONS TO STRUCTURALMEMBERS IS PROHIBITED WITHOUT WRITTEN AUTHORIZATION OF THE STRUCTURALENGINEER.ANY UNAUTHORIZED DEVIATION FROM THE CONTRACT DOCUMENTS, ANDCORRECTION THEREOF, IS THE RESPONSIBILITY OF THE CONTRACTOR.FOUNDATIONS:THE FOUNDATION DESIGN OF THIS PROJECTS WAS BASED ON ASSUMED BEARINGCAPACITY OF 2500 PSF.THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OR ENGINEER OF RECORDIMMEDIATELY IN THE EVENT THAT THE SOIL CONDITION ENCOUNTERED VARY FROMTHOSE SHOWN ON BORING LOGS.ALL FOUNDATION EXCAVATIONS SHALL BE INSPECTED BY A SOILS TESTINGLABORATORY PRIOR TO PLACEMENT OF CONCRETE.FOUNDATION BEARING SURFACES SHALL BE INSPECTED UNDER THE DIRECTION OFTHE PROJECT GEOTECHNICAL ENGINEER.COMPACT ALL FILL TO 98% OF OPTIMUM LABORATORY DENSITY IN ACCORDANCEWITH ASTM D698 STANDARD PROCTOR METHOD.ELEVATIONS OF THE EXISTING FOOTINGS ARE BASED ON THE BEST INFORMATIONAVAILABLE TO THE DESIGNERS. IT IS ANTICIPATED THAT THERE WILL BEVARIATIONS BETWEEN THE ACTUAL EXISTING FOUNDATIONS AND WHAT IS SHOWNON THE DRAWINGS.THE FOOTINGS SHOWN ARE TO BE USED AS A BASIS FOR BIDDING.UNIT COSTS AS SUBMITTED ON THE PROPOSAL FORM FOR IN-PLACE CONCRETE(CY), EXCAVATION (CY), AND REINFORCING STEEL (LB), SHALL APPLY TO ANYVARIATIONS IN THE FOUNDATIONS AND PIERS.CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING,SHEATHING, AND SHORING REQUIRED AND SHALL BE SOLELY RESPONSIBLE FORALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, AND PROTECTIONOF ADJACENT PROPERTY, STRUCTURES, STREETS, AND UTILITIES IN ACCORDANCEWITH ALL NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES.DO NOT BACKFILL AGAINST FOUNDATION OR BASEMENT WALLS UNTIL FLOORSLAB/FRAMING IS IN PLACE OR PERMISSION IS OBTAINED FROM THE ARCHITECT.EXCEPT FOR CANTILEVER RETAINING WALLS OR UNLESS NOTED OTHERWISE ONDRAWINGS, SUBGRADE WALLS ARE SUPPORTED BY THE FLOOR ABOVE AND BELOW.PROPER TEMPORARY BRACING MAY BE USED IN LEIU OF THE FLOOR SUPPORTBASED ON THE DESIGN BY A PROFESSIONAL ENGINEER.ALL FOOTINGS ARE TO REST ON FIRM, LEVEL, UNDISTURBED SOIL OR ENGINEEREDFILL, OF BEARING CAPACITY NOTED, REGARDLESS OF ELEVATIONS SHOWN ONDRAWINGS.WHERE ROCK OR SHALE IS THE BEARING MATERIAL, PROVIDE 6" DEEPPENETRATION. ALL SOIL SURROUNDING AND UNDER FOOTINGS SHALL BEPROTECTED FROM FROST ACTION AND FREEZING DURING THE COURSE OFCONSTRUCTION.VERIFICATION AND INSPECTION TASKCONTINUOUSDURINGTASK LISTEDPERIODICALLYDURINGTASK LISTED1. Verify materials below footings are adequate toachieve the design bearing capacity.YYTABLE 1704.7REQUIRED VERIFICATION AND INSPECTION OF SOILSFREQUENCY OFINSPECTION2. Verify excavations are extended to proper depth and have reached proper material.3. Perform classification and testing of controlled fill materials.4. Verify use of proper materials, densities and liftthickneses during placement and compaction ofcontrolled fill.5. Prior to placement of controlled fill, observe subgradeand verify that site has been prepared properly.--REQUIREDFORPROJECTYYYYYYY--------YTHE FOLLOWING SHOP DRAWINGS AND CALCULATIONS, WHEN APPLICABLE, AREREQUIRED FOR SUBMITTAL FOR STRUCTURAL REVIEW: A) STRUCTURAL STEEL B) SPLICED REINFORCING C) CONCRETE MIX DESIGNS D) STEEL DECK E) LIGHT GAGE METAL STUD FRAMING F) UNISTRUTS FOR PIPE SUPPORTSSHOULD ANY OF THE GENERAL NOTES CONFLICT WITH ANY DETAILS OR INSTRUCTIONS ONPLANS OR IN THE SPECIFICATIONS, THE STRICTEST PROVISON SHALL GOVERN.REFER TO AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FORCONSTRUCTION" FOR GENERAL CONDITIONS.REFER TO THE SPECIFICATIONS FOR: QUALITY OF WORK, PERFORMANCE, STRENGTH ANDPHYSICAL REQUIREMENTS FOR MATERIALS, STANDARDS, CODES AND REGULATIONS (EXCEPTAS NOTED HEREIN) AND GUARANTEES.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, CONDITIONS RELATED TOEXISTING CONSTRUCTION, AND EXISTING SERVICES IN THE FIELD PRIOR TO COMMENCINGWORK. THE ARCHITECT AND ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES WHICHMAY EXIST.ANY DISCREPANCIES BETWEEN STRUCTURAL AND ARCHITECTURAL DRAWINGS SHALL BEBROUGHT TO THE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER.STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE MEANS, METHODS,TECHNIQUES, SEQUENCES, OR PROCEDURES OF CONSTRUCTION SELECTED BY THECONTRACTOR.DO NOT SCALE DRAWINGS.PARTS OF THE STRUCTURE AFFECTED BY OPENINGS RELATED TO MECHANICALREQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY. THE GENERALCONTRACTOR SHALL VERIFY THESE CONDITIONS WITH MECHANICAL AND OTHER TRADES ANDINCLUDE ANY ADDITIONAL COSTS IN BASE BID.ELEVATION MARK:NORTH ARROW:DETAIL BUBBLE:SECTION CUT:XWC WSSECTION NUMBERWHERE CUTWHERE SHOWNXWC WSXWC WSXWSXWSNT/SLAB0'-0"COLCENTERLINEOF COLUMN:SYMBOLS WALL SECTIONMARK:ELEVATIONMARK:TS1 (2,3,...)FOUNDATIONFND.THICKENED SLAB SCHEDULE MARKTYP.XXSPCYD.VERT.W.P.W/WWWFWD.XSPCW/OWF1 (1,2,...)U.N.O.INCH (ES)JT.JST.INT.INTERIORJOINTJOISTGA.IN.I.D.HT.GALV.HOR.FT.FTG.FSFRMG.GAUGEHORIZONTALGALVANIZEDINNER DIAMETERHEIGHTFAR SIDEFEET OR FOOTFRAMINGFOOTINGUNLESS NOTED OTHERWISEEXTRA STRONG PIPE COLUMNSTRIP FOOTING SCHEDULE MARKDOUBLE EXTRA STRONG PIPE COLUMNYARDTYPICALVERTICALWITHOUTWITHWOODSTEEL BEAMWELDED WIRE FABRICWORKING POINTMAT.MAX.MFR.MC1 (1,2,...)MECH.MB1 (1,2,...)K.LGTH.LT. GA.OPG.O.D.O.C.P.S.F.P.S.I.MISC.N.I.C.MIN.NSNOM.NS/FSN.T.S.REF.RF.REINF.REQMTS.REQD.P/CPAR.PL.R.D.PLY.P/CPREFAB.P.T.SYM.T&BT&GS.F.S.S.SPCSECT.STR.STL.STD.SPECS.SCHDL.TST/CBT/BMT/TBTHK.TB1 (1,2,...)T/SLABT/STLT/FTGT/TDS1 (2,3,...)FOOTING SCHEDULE MARKELECTRICALELEC.FIN. GR.FIN. FLR.F1 (2,3,...)FLR.F.D.EQ. SP.EXIST.EXP.EXT.ENGR.FLOOR DRAINFINISHED GRADEFINISHED FLOORFLOOREXTERIOREXPANSIONENGINEEREXISTINGEQUAL SPACEDE.F.EL.EJE.W.EA.DTL.DWG.DR.DN.DIST.EACH FACEEACH WAYELEVATIONEXPANSION JOINTEACHDRAWINGDISTANCEDETAILDRAINDOWNCONCRETE MASONRY UNITCONTROL OR CONSTRUCTION JOINTCONCRETE COLUMN SCHEDULE MARKSTEEL COLUMN SCHEDULE MARKCONCRETE BEAM SCHEDULE MARKCJCONTR.DEPT.DIA.DIM.CONT.CONST.CONC.CONN.CLR.COL.CONTRACTORCONTINUOUSDIAMETER(S)DIMENSIONDEPARTMENTCONNECTIONCONCRETECONSTRUCTIONCLEARCOLUMNC.M.U.C1 (2,3,...)CC1 (2,3,...)CB1 (2,3,...)C.Y.C.F.C.I.P.C.L.BRG.CCUBIC YARDCENTER LINECUBIC FEETSTEEL CHANNELCAST IN PLACEBEARINGAMERICAN WELDING SOCIETYAMERICAN CONCRETE INSTITUTEAMERICAN IRON AND STEEL INSTITUTEAMERICAN INSTITUTE OF STEEL CONSTRUCTIONBEAM SCHEDULE MARKA.I.S.I.B1 (1,2,...)BLK.BOT.BM.BETW/BLDG.ALUM.ARCH.ALT.A.W.S.BETWEENBUILDINGBLOCKBEAMBOTTOMALTERNATEALUMINUMARCHITECTURALABBREVIATIONS &A.I.S.C.A.C.IA.B.@#ANDANCHOR BOLTSATNUMBERLNEAR SIDE AND FAR SIDESCHEDULESTANDARD PIPE COLUMNTOP OF CONCRETE BEAMTURNED DOWN SLAB SCHEDULE MARKCONCRETE TIE BEAM SCHEDULE MARKTOP OF BEAMTUBE STEELTHICKTOP OF SLABTOP OF TIE BEAMTOP OF STEELTOP OF FOOTINGSTEELSECTIONSTANDARDSTRUCTURALSYMMETRICALSPECIFICATIONSTOP AND BOTTOMTONGUE & GROOVETOP OF....POUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHREFERENCEREQUIREDROOFPLYWOODROOF DRAINREINFORCEMENTREQUIREMENTSPREFABRICATEDSTAINLESS STEELSQUARE FEETOPENINGON CENTEROUTSIDE DIAMETERPLATEPRECASTPARALLELPRECAST CONCRETEPRESSURE TREATEDMASONRY BEAM SCHEDULE MARKMASONRY COLUMN SCHEDULE MARKMECHANICALMANUFACTURERMINIMUMNOMINALNEAR SIDENOT IN CONTRACTNOT TO SCALEMISCELLANEOUSMATERIALMAXIMUMSTEEL ANGLELIGHT GAUGELENGTHKIPINTERNAL PRESSURE COEFFICIENT (ENCLOSED FOR TERMINAL, SKYWALK, ETC.) GCPI = ±0.18TOPOGRAPHIC FACTOR Kzt=1.0 WIND DIRECTIONALITY FACTOR Kd=0.85 DESIGN AND LOADING1. THE STRUCTURAL DESIGN OF THIS BUILDING WAS BASED ON THE DESIGN CRITERIA:A. BUILDING CODE: FLORIDA BUIILDING CODE 2014 (5TH. EDITION)B. FLOOR: LIVE LOAD: 100 PSF (SLAB ON GRADE)D. ROOF: LIVE LOAD: 20 PSF DEAD LOAD: 25 PSFE. WIND:BASIC WIND SPEED: 112 MPH (3-SECOND GUST)ULTIMATE WIND SPEED: 144 MPH (3 SECOND GUST)RISK CATEGORY CLASSIFICATION: IIIWIND EXPOSURE CATEGORY: CPRESSURES PER ASCE7-10F. LIGHT GAGE PARTITIONS: 10PSFG. FLOOD LOAD: N/AC. INTERMEDIATE LEVEL: LIVE LOAD: 100 PSF DEAD LOAD: 85 PSFH. SPECIAL LOADS: N/A07-14-2017CONFORMED SET161
CAST-IN-PLACE CONCRETE CONSTRUCTION:ALL CONCRETE WORK IS TO BE IN ACCORDANCE WITH "SPECIFICATIONS FORSTRUCTURAL CONCRETE FOR BUILDING ACI 301", LATEST EDITION ASSUPPLEMENTED BY THE PROJECT SPECIFICATIONS.CONCRETE WORK IN COLD WEATHER SHALL CONFORM TO ALL REQUIREMENTS OFTHE LATEST EDITIONS OF ACI 306.1 "STANDARD SPECIFICATION FOR COLDWEATHER CONCRETING" AND ACI 306R "COLD WEATHER CONCRETING".CONCRETE WORK IN HOT WEATHER SHALL CONFORM TO ALL REQUIREMENTS OFTHE LATEST EDITION OF ACI 305R "HOT WEATHER CONCRETING". THE AIRTEMPERATURE, CONCRETE TEMPERATURE AND WIND VELOCITY SHALL BEENTERED INTO THE NONGRAPH FIGURE 2.1.5 TO DETERMINE IF PRECAUTIONSAGAINST PLASTIC SHRINKAGE ARE REQUIRED.ALL CONCRETE CONSTRUCTION TO BE IN ACCORDANCE WITH THE LATEST EDITIONSOF "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE ACI 318-14" ANDACI DETAILING MANUAL, EXCEPT THAT CONSTRUCTION AND REMOVAL OF FORMSAND RESHORING SHALL BE INSPECTED BY THE CONTRACTOR'S ENGINEER.CONCRETE SHALL DEVELOP A COMPRESSIVE STRENGTH IN 28 DAYS OF: A) FOR ISOLATED, SPREAD & TRENCH FOUNDATIONS: 3000 PSI B) FOR GRADE BEAMS, CAISSON CAPS & ALL OTHER CONCRETE: 4000 PSIADMIXTURES: A) USE HIGH RANGE WATER REDUCER (HRWR) FOR ALL SLABS ON GRADE AND SLABS ON METAL FORM. ASTM C494. B) ALL CONCRETE EXPOSED TO WEATHER OR VEHICULAR TRAFFIC SHALL CONTAIN AND APPROVED AIR-ENTRAINING AGENT. USE 6% ENTRAINED AIR, PLUS 1%/MINUS 1.5%. C) THE USE OF CALCIUM CHLORIDE AND ADMIXTURES CONTAINING CALCIUM CHLORIDE IS PROHIBITED.FLYASH CONTENT, IF APPROVED IN ADVANCE BY ENGINEER, SHALL BE LIMITEDTO 25% OF TOTAL CEMENTITIOUS MATERIAL.GROUND GRANULATED BLAST FURNACE SLAG (GGBFS) IS NOT PERMITTEDREINFORCEMENT: A) REINFORCING STEEL SHALL BE PER ASTM A615 GRADE 60, 60,000 PSI YIELD. B) REINFORCING BARS FOR WELDED APPLICATIONS SHALL CONFORM TO ASTM A706, 60 KSI YIELD STRENGTH. ALL BENDING TO BE DONE AFTER WELDING. C) EPOXY COATED REINFORCING BARS PER ASTM A615. USE EPOXY COATED BARS IN FROST SLABS. D) WELDED WIRE FABRIC SHALL BE OF FLAT SHEETS AND CONFORM TO ASTM A185. E) WELDED WIRE FABRIC IN SLAB-ON-GRADE APPLICATIONS SHALL BE SUPPORTED BY "MESH-UPS" AS MANUFACTURED BY LOTEL, INC. (HTTP://WWW.LOTEL.COM/MESHUPS.HTML). USE ONE - 2" MESH-UP PER 3 SQUARE FEET. F) WIRE MESH REINFORCEMENT SHALL LAP ONE MESH SIZE AT SIDES AND ENDS AND BE WIRED TOGETHER. REINFORCING FOR SLABS SHALL BE IN THE MIDDLE OF SLAB UNLESS NOTED OTHERWISE. DEPTH SHALL BE MAINTAINED AND SUPPORTED AS REQUIRED DURING PLACEMENT OF CONCRETE. G) NO TACK WELDING OF REINFORCING STEEL WILL BE PERMITTED. H) WHERE REINFORCING IS SHOWN CONTINUOUS THROUGH CONSTRUCTION JOINTS, MECHANICAL BAR SPLICE DEVICES MAY BE USED. SIZES AND TYPES SHALL BE SELECTED TO DEVELOP THE FULL TENSION STRENGTH OF THE BAR. SUBMIT FOR APPROVAL BY STRUCTURAL ENGINEER.IN REINFORCED CONCRETE WALLS AND TRENCH FOOTINGS PROVIDE CORNERDOWELS OF SAME SIZE AND SPACING AS HORIZONTAL REINFORCING.PROVIDE THE FOLLOWING ADDITIONAL REINFORCING AT OPENINGS IN CONCRETEWALLS: A) 1-#5 AT EACH FACE OF WALL AT EACH OPENING. EXTEND 2'-0" BEYOND OPENING (TYPICAL). B) 1-#5 X 4'-0" LONG AT EACH FACE OF WALL DIAGONALLY AT EACH CORNER.ALL WALL FOOTING REINFORCING SHALL EXTEND THROUGH CENTERLINE OFCOLUMN FOOTINGS.FURNISH BAR SUPPORTS WHERE NECESSARY DURING CONSTRUCTION.PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCEMENT PER CRSIRECOMMENDATIONS.PROVIDE PLASTIC-COATED (NOT PLASTIC-TIPPED) OR STAINLESS STEEL CHAIRS INALL CONCRETE EXPOSED TO VIEW IN COMPLETE STRUCTURE.ALL KEYS IN CONCRETE WALLS SHALL BE 2"X4" UNLESS NOTED OTHERWISE.PROVIDE A MINIMUM OF 2-#4 BARS IN TOP OF ALL CONCRETE BEAMS WITHSTIRRUPS.SEE THESE DRAWINGS FOR ADDITIONAL RESTRICTIONS ON THE PLACEMENT OFOPENINGS IN SLABS AND WALLS.PIPES LARGER THAN 1 1/2"Ø SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETEEXCEPT WHERE SPECIFICALLY APPROVED BY ENGINEER. PIPES SHALL NOTDISPLACE OR INTERRUPT REINFORCING BARS. SPACE EMBEDDED PIPES AT AMINIMUM OF 3 DIAMETERS.PROVIDE 4" MINIMUM COVER FOR ALL STRUCTURAL STEEL BELOW GRADE.REINFORCING STEEL SHOP DRAWINGS SHALL INDICATE THE SEQUENCE IN WHICHLAYERS OF CROSSING REINFORCING SHOULD BE PLACED IN ORDER TO PRODUCETHE CORRECT OUTERMOST LAYERS AS INDICATED ON THE DRAWINGS.ALL CONCRETE ACCESSORIES EXPOSED TO WEATHER SHALL BE CORROSIONRESISTANT.CONCRETE SHALL BE DISCHARGED AT THE SITE WITHIN 1 1/2 HOURS AFTER WATERHAS BEEN ADDED TO THE CEMENT AND AGGREGATES. ADDITION OF WATER TO THEMIX AT THE PROJECT SITE WILL NOT BE PERMITTED. ALL WATER MUST BE ADDED ATTHE BATCH PLANT. SLUMP MAY BE ADJUSTED ONLY THROUGH THE USE OFADDITIONAL WATER REDUCING ADMIXTURE OR OR HIGH RANGE WATER REDUCINGADMIXTURE (HRWR).SEE ARCHITECTURAL AND DRAWINGS AND SPECIFICATIONS AND STRUCTURALPLANS FOR VAPOR BARRIER REQUIREMENTS. VAPOR BARRIER, WHERE REQUIRED,SHALL BE PLACED OVER COMPACTED GRANULAR SUBBASE.AT RE-ENTRANT CORNERS, PROVIDE (2)-#4 X 3'-0" LONG HORIZONTAL REINFORCINGAT TOP OF SLAB.4,0003,0005,000INCREASE SPLICE LENGTHBY THE FOLLOWING:INCREASE:* HORIZONTAL TOP BARS WITH GREATER THAN 12" OF CONCRETE BELOW . . .* BAR SPACING LESS THAN 3 BAR DIAMETERS . . . . . . . . . . . . . .* LIGHTWEIGHT CONCRETE . . . . . . .* EPOXY-COATED TOP BARS . . . . .* EPOXY-COATED OTHER BARS . . . .(INCREASED LENGTHS ARE CUMULATIVE)+30%+40%+30%+31%+50%BARSIZECONCRETESTRENGTH16"22"27"35"48"63"80"102"125"#3#4#5#6#7#8#9#10#1116"19"23"31"42"55"69"88"108"16"17"21"27"37"49"62"79"97"SUBMITTALS: A) SUBMIT DATA FOR PROPRIETARY MATERIAL AND ITEMS INCLUDING ADMIXTURES, CURING COMPOUND, INSERTS, ETC. B) SUBMIT SHOP DRAWINGS OF REINFORCEMENT SHOWING BAR SCHEDULES AND DIAGRAMS TOGETHER WITH PLACEMENT DRAWINGS COMPLYING TO ACI 315. C) SUBMIT PROPOSED CONCRETE MIX DESIGN INCLUDING DATA ON AGGREGATES AND CEMENT.SPLICES: A) LAP ALL COMPRESSION SPLICES 30 BAR DIAMETERS OF THE LARGER BAR. B) LAP ALL TENSION SPLICES IN ACCORDANCE WITH THE FOLLOWING TABLE:MINIMUM LAP SPLICE AND DEVELOPMENT LENGTH TABLE:WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP DIMENSION OF THE SMALLERBAR.MINIMUM CONCRETE COVER FOR REINFORCING: LOCATION MINIMUM COVERCAST AGAINST AND PERMANENTLY EXPOSED TO EARTH . . . . . . . . . . . . . . . . 3"EXPOSED TO EARTH OR WEATHER: #6 AND LARGER . . . . . . . . . . . . . . . . . . 2" #5 AND SMALLER . . . . . . . . . . . . . . . . . 1 1/2"NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS & WALLS #11 AND SMALLER . . . . . . . . . . 3/4" BEAMS, GIRDERS, COLUMNS, PRINCIPAL REINF., TIES AND STIRRUPS . . . . . . . . . . . . 1 1/2"CONCRETE REINFORCING SHALL BE PLACED PER THE TOLERANCES OF ACI 117AND ACI 318.SLABS ON GRADE:CONTROL JOINTS SHALL BE CREATED BY SAW CUTS, 1/8" WIDE TO A DEPTHEQUAL 1/4 OF THE SLAB THICKNESS, LOCATED ON COLUMN CENTER LINES ANDAT 12'-0" (PLUS OR MINUS 5'-0") ON CENTER IN EACH DIRECTION, UNLESSNOTED OTHERWISE.CONSTRUCTION JOINTS SHALL BE KEYED AND LOCATED AT CONTROL JOINTINTERVALS.CURE ALL SLABS USING A MOISTURE-RETAINING COVER OR WET CURE PROCEDURES.KEY AND DOWEL OFF AREAWAYS AND OTHER PROJECTING ELEMENT TOSUPPORTING WALLS WITH #4 BARS AT 12" ON CENTER EXTENDING 1'-0" INTOSUPPORTING WALL UNLESS NOTED.PROVIDE FOUNDATION DOWELS FOR ALL WALLS, PIERS, AND COLUMNS SAME SIZEAND SPACING AS SUPPORTING STEEL.SLUMP SHALL BE MEASURED PRIOR TO THE ADDITION OF HRWR.IF FOUNDATIONS BEAR INTO SHALE OR ROCK, ELEVATIONS GIVEN AREAPPROXIMATE AND SHALL BE ADJUSTED TO SUIT FIELD CONDITIONS.SHALE PROTECTION MAY BE REQUIRED. CONSULT GEOTECHNICAL REPORT.BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BE AT LEAST 3'-8" BELOW FINISHEDGRADE.STEP BOTTOM OF FOOTING, WHERE REQUIRED, AT A RATE OF 1 UNIT VERTICAL TO 2UNITS HORIZONTAL. MAXIMUM VERTICAL STEP TO BE 2'-0".WHERE FOOTINGS ARE IN CLOSE PROXIMITY OF SEWERS, BOTTOM OF FOOTINGSSHALL BE AT LEAST 8" BELOW INVERT ELEVATION OF SEWERS.KEEP FOUNDATION EXCAVATIONS FREE OF WATER AT ALL TIMES.USE LEAN CONCRETE (F'C=1500 PSI) FOR OVER-EXCAVATION OF FOOTINGS ANDREPLACEMENT OF WEAKENED SOIL.JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S004.dwg Jul 12, 2017 - 2:30pm daranS120141/4" =1'-0"1-S004MASONRY:MATERIALS:MINIMUM PRISM STRENGTH F'M = 1900 PSI (AVG./3 UNITS)HOLLOW LOAD BEARING UNITS ASTM C90SOLID LOAD BEARING UNITS ASTM C145CONCRETE BRICK ASTM C55MORTAR (TYPE S, 1800 PSI CUBE STRENGTH) ASTM C270BRICK (GRADE SW, TYPE FBS, 8000 PSI MIN STRENGTH) ASTM C216GROUT (COMPRESSIVE STRENGTH OF 3000 PSI MIN) ASTM C476REINFORCEMENT: A) PROVIDE HORIZONTAL JOINT REINFORCEMENT PER ASTM A82, EXTRA HEAVY WEIGHT, LADDER TYPE, GALVANIZED AFTER FABRICATION, AT 16" CENTERS VERTICALLY ABOVE GRADE AND AT 8" CENTERS VERTICALLY BELOW GRADE. HORIZONTAL REINFORCEMENT TO BE CONTINUOUS AROUND AND THROUGH ALL CORNERS USING FACTORY PREFABRICATED "CORNER" AND "TEE" SECTIONS. STOP HORIZONTAL REINFORCEMENT AT CONTROL JOINTS AND EXPANSION JOINTS. B) REINFORCING BARS PER ASTM A615, GRADE 60, LAP SPLICES 48 DIAMETERS MINIMUM AND GROUT SOLID INTO WALLS FULL HEIGHT. C) PROVIDE DOWELS INTO FOOTING TO MATCH WALL REINFORCING ABOVE. D) WELDING OF REINFORCING BARS, INCLUDING TACK WELDING, IS NOT PERMITTED.MASONRY ELEMENTS ARE DESIGNED IN ACCORDANCE WITH "BUILDING CODEREQUIREMENTS FOR MASONRY STRUCTURES" ACI 530 (LATEST EDITION),PUBLISHED BY THE AMERICAN CONCRETE INSTITUTE.MATERIALS AND CONSTRUCTION METHODS SHALL BE AS SPECIFIED IN"SPECIFICATIONS FOR MASONRY STRUCTURES" ACI 530.1 (LATEST EDITION),PUBLISHED BY THE AMERICAN CONCRETE INSTITUTE.DURING CONSTRUCTION, MASONRY WALLS ARE TO BE BRACED IN ACCORDANCEWITH "STANDARD PRACTICE FOR BRACING MASONRY WALLS UNDERCONSTRUCTION" BY THE COUNCIL FOR MASONRY WALL BRACING. CONTRACTOR ISSOLELY RESPONSIBLE TO MEET THESE REQUIREMENTS.WALLS SHOWN ON STRUCTURAL DRAWINGS ARE FOR CLARITY ONLY. SEEARCHITECTURAL DRAWINGS FOR THE LOCATION OF, AND COMPOSITION OFMASONRY WALLS EXCEPT PIERS.ALL HOLLOW UNITS SHALL BE LAID WITH FULL MORTAR COVERAGE ON HORIZONTALAND VERTICAL EDGES OF FACE SHELLS. WEBS SHALL ALSO BE BEDDED IN ALLCOURSES OF BEARING WALLS, PIERS, COLUMNS AND PILASTERS. STARTINGCOURSE ON FOOTINGS ADJACENT TO CELLS OR CAVITIES SHALL BE FILLED WITHGROUT.SOLID UNITS SHALL BE LAID WITH FULL HEAD AND BED JOINTS.COLLAR (VERTICAL LONGITUDINAL) JOINTS BETWEEN THE FACING AND BACKINGWYTHES IN WALLS SHALL BE COMPLETELY FILLED WITH MORTAR OR GROUT WHICHSHALL BE WORKED IN WITH A TROWEL.MORTAR PROTRUSIONS EXTENDING INTO CELLS OR CAVITIES TO BE GROUTEDSHALL BE REMOVED.IN MASONRY WALLS NO CHASES, RISERS, CONDUITS, OR TOOTHING OF MASONRYSHALL OCCUR WITHIN 17" OF CENTERLINE OF BEAM BEARING OR LOADCONCENTRATION.UNLESS NOTED OTHERWISE, PROVIDE A MINIMUM OF 16" DEPTH OF SOLIDMASONRY UNDER THE BEARING ENDS OF ALL BEAMS AND LH AND DLH SERIESSTEEL JOISTS AND 8" DEPTH OF SOLID MASONRY UNDER THE BEARING ENDS OFALL SLABS, LINTELS AND K SERIES JOISTS.BOLTS OR ANCHORS SHALL BE EMBEDDED IN GROUT.INTERSECTING LOAD BEARING WALLS SHALL BE TIED TOGETHER IN MASONRY BONDUNLESS NOTED OTHERWISE.CALCIUM CHLORIDE OR ADMIXTURES CONTAINING CALCIUM CHLORIDE SHALL NOTBE USED IN MORTAR OR GROUT.PROVIDE AN ADDITIONAL 2 - #5 BARS AT EACH SIDE OF ALL OPENINGS AS WELL ASABOVE AND BELOW EACH OPENING AND AT THE ENDS OF WALLS (INCLUDINGCONTROL JOINTS). BARS TO EXTEND A MINIMUM OF 24" PAST THE EDGE OFOPENINGS.ALL BEAM POCKETS IN MASONRY WALLS SHALL BE FILLED SOLID WITH SOLIDMASONRY OR CONCRETE.MASONRY VENEER TIES TO STUD WALLS: A) PROVIDE HOHMAN BARNARD X-SEAL SERIES WITH VEE WALL TIES OR APPROVED EQUAL. B) ANCHORS AND TIES SHALL BE HOT DIP GALVANIZED. C) WITH LIGHT GAGE METAL STUDS, SECURE WITH #10 HEX HEAD SCREWS WITH CORROSION RESISTANT ORGANIC POLYMER COATING AND NEOPRENE WASHERS. D) SPACE ANCHORS AT 16" HORIZONTAL AND VERTICAL TYPICALLY AND 8" VERTICALLY AT PERIMETER OF WALL PENETRATIONS.SUBMITTALS: A) SUBMIT DATA FOR MASONRY UNITS, MORTAR, GROUT, JOINT REINFORCING AND ACCESSORIES. B) SUBMIT SHOP DRAWINGS OF REINFORCEMENT SHOWING WALL ELEVATION, BAR SCHEDULES, DIAGRAMS AND DETAILS AS REQUIRED BY ACI 530.1.STRUCTURAL STEELMATERIALS:W AND S SHAPES . . . . . . . . . . . ASTM A992 OR A572, GRADE 50TS/HSS SHAPES . . . . . . . . . . . . ASTM A500, GRADE B, 46 KSIPIPE, TYPE E OR S, GRADE B . . . . . ASTM A501 OR A53OTHER SHAPES, INCLUDING BUT NOTLIMITED TO ANGLES, CHANNELS, BEARING,BASE AND CAP PLATES, ETC.) . . . . . . . ASTM A36, 36 KSIBOLTS (3/4" DIAMETER, TURN OF NUT METHODUNLESS NOTED OTHERWISE) . . . . . . . . . ASTM A325ANCHOR BOLTS . . . . . . . . . . . . . . . ASTM F1554WELDING ELECTRODE . . . . . . . . . . . . AWS E70XX COATED TYPE, LOW HYDROGEN CLASSIFICATION.DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TOTHE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)SPECIFICATIONS.CONNECTIONS (WELDED OR HIGH STRENGTH BOLTED): A) NON-COMPOSITE MEMBERS: DESIGN CONNECTIONS FOR FULL STRENGTH OF MEMBER FOR SPAN PER AISC BEAM LOAD TABLES. B) COMPOSITE MEMBERS: SEE COMPOSITE BEAM DETAILS FOR CONNECTION REQUIREMENTS. C) A325SC WITH HARDENED WASHERS- USE FOR ALL MOMENT CONNECTIONS, WIND CONNECTIONS, HANGERS, AND OTHER CONNECTIONS AS NOTED ON DRAWINGS. D) A325N WITH HARDENED WASHERS- USE FOR ALL CONNECTIONS OTHER THAN SLIP CRITICAL CONNECTIONS. E) WHEREVER POSSIBLE, USE FRAMED BEAM CONNECTIONS AS LISTED IN TABLES II, III, OR IV OF AISC MANUAL OF STEEL CONSTRUCTION. THE LENGTH OF CONNECTION ANGLES SHALL BE NOT LESS THAN HALF THE "T" DISTANCE OF THE BEAM WEB. F) ONE SIDED CONNECTIONS WILL NOT BE PERMITTED UNLESS DETAILED ON THE DRAWINGS. G) BOTTOMS OF ALL CONNECTIONS SHALL BE AT LEAST 6" ABOVE FINISHED CEILING. H) ALL SLIP CONNECTIONS SHALL BE PROVIDED WITH A MEANS OF PREVENTING THE NUTS FROM UNTHREADING. I) USE STANDARD HOLES WITH THE FOLLOWING EXCEPTION: OVERSIZE HOLES ARE PERMITTED WHEN BOLTS ARE LOADED IN TENSION; SHORT SLOTTED HOLES ARE PERMITTED FOR SHEAR LOADING PERPENDICULAR TO THE SLOT. J) WHERE REACTION IS NOTED, DEVELOP SAME.PAINTING: A) PROVIDE 1 SHOP COAT AND ONE FIELD COAT OF RUST-INHIBITIVE PAINT. SEE SPECIFICATIONS FOR MORE INFORMATION. B) DO NOT PAINT BEAMS THAT ARE ENCASED IN CONCRETE OR TO RECEIVE SPRAY-ON FIRE PROOFING. C) OMIT PAINT AT SLIP CRITICAL CONNECTIONS AND AREAS TO BE WELDED.SHOP DRAWINGS ARE REQUIRED AND SHALL NOTE TYPE OF ELECTRODES, SIZE OFALL WELDS, AND TYPE AND SIZE OF ALL BOLTS. SHOP DRAWINGS SHALL BEPREPARED UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER.ALL WELDING AND HIGH STRENGTH BOLTING MUST BE INSPECTED BY A QUALIFIEDTESTING LABORATORY. LABORATORY SHALL BE APPROVED BY THE ARCHITECTAND/OR ENGINEER.ALL WELDING SHALL CONFORM TO THE "CODE FOR ARC AND GAS WELDING INBUILDING CONSTRUCTION" OF THE AWS AND BE PERFORMED BY A RECENTLYCERTIFIED WELDER IN ACCORDANCE WITH AWS STANDARDS.SEQUENCE OF PLACING WELDS SHALL BE SUCH AS TO AVOID DISTORTION OFMEMBERS.WELD LENGTHS CALLED FOR ON PLANS ARE THE NET EFFECTIVE LENGTHREQUIRED. WHERE FILLET WELD SYMBOL IS GIVEN WITHOUT INDICATION OF SIZE,USE MINIMUM SIZE WELDS AS SPECIFIED IN AISC MANUAL OF STEELCONSTRUCTION, LATEST EDITION.NO WELDING OR FINAL BOLTING SHALL BE DONE UNTIL STRUCTURE HAS BEENPROPERLY ALIGNED.BEAMS BEARING ON MASONRY SHALL HAVE ANGLE WALL ANCHORS AS SHOWN INTHE AISC MANUAL EXCEPT ANGLES SHALL BE WELDED TO THE BEAMS.PROVIDE 1/2"X8X0'-8 BEARING PLATES FOR ALL WALL BEARING BEAMS UNLESSNOTED OTHERWISE.ALL LOOSE BEAM LINTELS SHALL HAVE 8" MINIMUM BEARING UNLESS NOTED.PROVIDE 9/16"Ø ROUND HOLES AS REQUIRED BY ARCHITECTURAL DRAWINGS FORWOOD NAILERS.ALL STRUCTURAL STEEL BEAMS AND COLUMNS ADJACENT TO MASONRY SHALLHAVE 1 1/2 X 1/8" STRAP ANCHORS AT 2'-8"OC OR APPROVED EQUAL.PROVIDE 1/16" DRAW FOR EACH 10'-0" LENGTH OF BRACING.ATTACHMENT OF ALL MECHANICAL EQUIPMENT TO THE STRUCTURE, INCLUDING,BUT NOT LIMITED TO HVAC ROOFTOP UNITS, ROOFTOP UNIT CURBS, ETC. ARE TOBE SPECIFIED BY THE MECHANICAL ENGINEER AND MECHANICAL CONTRACTOR.LOOSE LINTEL SCHEDULE:USE 1 ANGLE FOR EACH 4" OF MASONRY WALL THICKNESS. UNLESS NOTEDOTHERWISE ON DRAWINGS, USE THE FOLLOWING FOR LOOSE LINTELS OVERDOORS, WINDOWS, DUCTS, AND MISCELLANEOUS OPENINGS. (3 1/2" LEG OF ANGLETO BE HORIZONTAL): ANGLE SIZE SPAN (MAX) MASONRY BEARING, EACH ENDL 4 X 3 1/2 X 5/16" UP TO 4'-0" 6"L 5 X 3 1/2 X 5/16" OVER 4'-0" TO 5'-0" 6"L 6 X 3 1/2 X 5/16" OVER 5'-0" TO 6'-6" 8"OUTERMOST ANGLE EXPOSED TO EXTERIOR SHALL BE 3/8" THICK MINIMUM ANDHOT-DIP GALVANIZED.STEEL JOISTS:STEEL JOISTS SHALL CONFORM TO AND BE ERECTED IN ACCORDANCE WITH THELATEST STEEL JOIST INSTITUTE (SJI) SPECIFICATIONS.STEEL JOISTS SHALL BE DESIGNED FOR THE NET UPLIFT FORCES INDICATED IN THEDESIGN LOADS.PROVIDE STEEL JOIST END ANCHORAGE, BRIDGING, AND BRIDGING ANCHORAGE INACCORDANCE WITH STANDARD SPECIFICATIONS OF THE SJI, LATEST EDITION.WELD STEEL JOIST BEARING ENDS TO STEEL SUPPORTS OR BEARING PLATES.SEE PAINTING SPECIFICATIONS FOR ALL PAINTING REQUIREMENTS. PROVIDE SHOPPRIME AND RUST-INHIBITIVE PAINT.ALL "K" SERIES JOISTS TO HAVE 3/8X4X0'-10 BEARING PLATES WITH TWO 1/2"ØANCHOR BOLTS X 18" LONG +2" HOOK UNLESS NOTED OTHERWISE.JOISTS ON COLUMN CENTERLINES OR NEAREST TO COLUMN CENTERLINES SHALLBE ANCHORED BY BOLTING.ALL JOISTS AT OR NEAREST COLUMN CENTERLINES SHALL BE BOLTED WITH 2-1/2"ØBOLTS AND SHALL BE WELDED AFTER ERECTION.EXTEND JOIST BEARING END 1" MINIMUM PAST CENTERLINE OF SUPPORTING BEAMWHERE POSSIBLE.ADJACENT JOISTS OF SAME DEPTH ARE TO HAVE WEB MEMBERS IN LINE TO PERMITPASSAGE OF MECHANICAL DUCT WORK.JOIST EXTENSIONS, WHETHER CANTILEVERED OR SUPPORTED, SHALL PROVIDE AMINIMUM LOAD SUSTAINING CAPACITY EQUAL TO THE JOIST.BOTTOM CHORDS OF STEEL TIE JOISTS SHALL NOT BE ATTACHED TO SUPPORTINGSTEEL FRAMING UNTIL AFTER THE DEAD LOAD OF THE ROOF OR FLOOR SYSTEMHAS BEEN INSTALLED. TEMPORARY BRACING OF STEEL FRAMING IS REQUIREDUNTIL ALL BOTTOM CHORD TIE JOIST CONNECTIONS ARE COMPLETED.NO MECHANICAL. ELECTRICAL, OR OTHER EQUIPMENT SHALL BE SUSPENDED FROMBRIDGING.PROVIDE JOIST REINFORCING AT CONCENTRATED LOADS NOT LOCATED AT PANELPOINTS. SEE DETAILS.PROVIDE 5" DEEP BEARING ENDS FOR STANDARD JOISTS WHICH HAVE A COMMONBEARING WITH LONG SPAN JOISTS.AT LONG SPAN JOISTS, HORIZONTAL TOP AND BOTTOM BRIDGING MAY BE USED INPLACE OF DIAGONAL BRIDGING ONLY WHERE REQUIRED TO PERMIT PASSAGE OFDUCT WORK. NO MORE THAN TWO ADJACENT JOIST SPACES MAY HAVEHORIZONTAL BRIDGING.METAL DECK:DECK - GENERAL:NO MECHANICAL, ELECTRICAL, OR OTHER EQUIPMENT SHALL BE SUSPENDED FROMMETAL DECK.ALL DECK SHALL BE GALVANIZED PER ASTM A653, CLASS G60.DECK SHALL HAVE A MINIMUM YIELD STRESS OF 33 KSI.MATERIALS FOR FLOOR AND ROOF DECK SHALL CONFORM TO ASTM A611, GRADESC, D, OR E.UNITS SHALL BE CONTINUOUS OVER THREE OR MORE SPANS, EXCEPT WHERE THEFRAMING DOES NOT PERMIT.SHORING MAY BE REQUIRED AT NON-CONTINUOUS SPANS. DECK SHOP DRAWINGSSHALL INDICATE WHERE SHORING WILL BE REQUIRED.DECK SHALL BEAR 2" MINIMUM AT ALL SUPPORTS.ALL WELDING OF STEEL DECK SHALL BE DONE BY CERTIFIED LIGHT GRADEWELDERS IN ACCORDANCE WITH AWS D1.3 "SPECIFICATIONS FOR WELDING SHEETSTEEL IN STRUCTURES". FLOOR DECK - NON-COMPOSITE: A) DECK AND ANCHORAGE SHALL BE PER STEEL DECK INSTITUTE (SDI) "SPECIFICATIONS FOR NON-COMPOSITE STEEL FLOOR DECK". B) METAL FLOOR DECK SHALL BE GALVANIZED NON-COMPOSITE TYPE, WITH ADEQUATE CAPACITY TO SUPPORT WET LOAD OF CONCRETE PLUS CONSTRUCTION LIVE LOAD IN ACCORDANCE WITH SDI SPECIFICATIONS FOR NON-COMPOSITE STEEL FROM DECK. C) WELD DECK TO SUPPORTING STEEL THROUGH WELDING WASHERS. D) DECK LAY-UP SHALL BE MULTIPLE SPAN UNSHORED. WHEN LOCAL CONDITIONS REQUIRE, PROVIDE SHORING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ROOF DECK: A) DECK AND ANCHORAGE SHALL BE PER STEEL DECK INSTITUTE (SDI) "SPECIFICATIONS FOR STEEL ROOF DECK". B) METAL ROOF DECK SHALL BE GALVANIZED AND SIZE AND GAUGE SHOWN ON DRAWINGS. C) DECK MANUFACTURER SHALL PROVIDE RIDGE AND VALLEY PLATES, STEEL CANT. STRIPS AND SUMP PANS AS REQUIRED TO PROVIDE A FINISH SURFACE FOR INSULATION AND ROOFING. D) DECK LAY-UP SHALL BE MULTIPLE SPANS, WELDED TO SUPPORT. E) METAL DECK SHALL BE WIDE RIB WITH NESTING SIDE SEAMS OF DEPTH AND GAGE INDICATED ON THE DRAWINGS. F) ATTACHMENT: METAL DECK SHALL BE ATTACHED TO ALL SUPPORTING STEEL WITH PUDDLE WELDS (5/8"Ø MINIMUM) OR POWER ACTUATED FASTENERS AT 12" CENTERS (5 PER SHEET MINIMUM). SIDE LAP CONNECTIONS SHALL BE MADE WITH #10 SELF TAPPING SCREWS AT A MAXIMUM OF 3'-0" CENTERS.(5)-#10 SELF TAPPINGSCREW MIDWAYBETWEEN SUPPORTS OR3'-0"OC MAXIMUM.DECK SUPPORT(MAY VARY)5/8"Ø PUDDLE WELD OR 0.157"Ø ORPOWER ACTUATED FASTENER - MIN. 7PER SHEET AT EACH DECK SUPPORT(THROUGH DOUBLE SHEET THICKNESSAT SIDE LAP).NOTE:PERIMETER WELDS OR POWERACTUATED FASTENERS PARALLELTO CORRUGATIONS TO BE5/8"Ø PUDDLE WELDS AT12"OC.DECK ATTACHMENT NOTES:TIGHT DECK TO SUPPORT CONTACT SHALL BE MAINTAINED AT ALL WELDLOCATIONS.WELDING ROD AMPERAGE AND BURN OFF RATE SHALL BE DETERMINED BY FIELDTESTING AS FOLLOWS: A 20'-0" LONG SECTION OF DECK SHALL BE ANCHORED TO A STEEL BEAM WITH TWO WELDS AT 6"OC. LEVERAGE SHOULD BE APPLIED TO THE PANEL. YIELDING SHOULD NOT BE NOTED AROUND WELD AND SUDDEN SEPARATION SHOULD NOT OCCUR ON THE CONTACT PLANE. SHOULD EITHER OCCUR, WELDING TIME AND/OR WELDING AMPERAGE SHALL BE ADJUSTED UNTIL ADEQUATE WELDING IS ACCOMPLISHED.TYPICAL DECK ATTACHMENT DETAIL36"PRE-ENGINEERED COLD-FORMED METAL FRAMING:ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE"AMERICAN IRON AND STEEL INSTITUTE" (AISI) "SPECIFICATION FOR THE DESIGN OFCOLD-FORMED STEEL STRUCTURAL MEMBERS", LATEST EDITION.COLD FORMED, LIGHT GAGE METAL FRAMING INCLUDING STUDS, JOISTS, RAFTERS,TRUSSES AND TRACKS SHALL BE PER ASTM A653, AND SHALL BE GALVANIZED INACCORDANCE WITH ASTM A924 WITH A MINIMUM OF G60 COATING.MINIMUM YIELD STRESS (FY) FOR 16 GA MEMBERS AND HEAVIER = 50 KSIMINIMUM YIELD STRESS (FY) FOR MEMBERS LIGHTER THAN 16 GA = 33 KSI (UNLESSNOTED OTHEWISE)MINIMUM SIZES SHOWN ARE AS IDENTIFIED BY "THE STEEL STUD MANUFACTURERSASSOCIATION" (SSMA).CONTRACTOR SHALL ENGAGE A PROFESSIONAL ENGINEER REGISTERED IN THESTATE OF FLORIDA. DESIGN AND DETAIL ALL LIGHT GAGE TRUSSES, JOISTS,RAFTERS, BEARING WALLS, CURTAIN WALLS, CONNECTIONS, ETC.STEEL TRUSSES, BEAMS AND RAFTERS SHALL BE LOCATED DIRECTLY OVER LOADBEARING STUDS OR STEEL ELEMENTS.LOAD BEARING STUDS SHALL BE FITTED TIGHTLY AND SECURED INTO TRACKS. ALLRUNNER TRACKS NOT SPECIFICALLY CALLED FOR ON THE STRUCTURAL DRAWINGSSHALL BE 12 GAUGE X 2" DEEP.PARTITIONS AND CURTAIN WALLS SHALL HAVE DEFLECTION TRACKS WITH AMINIMUM OF 1" DEFLECTION UNLESS NOTED OTHERWISE.PROVIDE 14-GAUGE WEB STIFFENERS WHERE NECESSARY AT REACTIONS POINTSAND AT ALL CONCENTRATED LOADS.FLOOR BRIDGING SHALL BE INSTALLED IMMEDIATELY AFTER JOISTS ARE ERECTEDAND BEFORE CONSTRUCTION LOADS.PROVIDE CLIP ANGLES OR OTHER ACCESSORIES AS REQUIRED FOR A COMPLETEINSTALLATION.ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TOPERPENDICULAR MEMBERS, OR AS REQUIRED FOR AN ANGULAR FIT AGAINSTABUTTING MEMBERS.STUDS SHALL BE PLUMBED, ALIGNED AND SECURELY ATTACHED TO BOTH FLANGESOF BOTH UPPER AND LOWER RUNNERS.FRAMING OF OPENINGS SHALL INCLUDE HEADERS AND SUPPORTING STUDS.UNPUNCHED MEMBERS SHALL BE USED FOR ALL JOISTS, HEADERS, ANDACCESSORIES. PUNCHOUTS IN STUDS SHALL BE A MINIMUM OF 10" FROM THE ENDOF THE STUD.NO SPLICES IN STUDS, JOISTS, OR HEADERS IS PERMITTED.DIAGONAL STRAP BRACING SHALL BE CONNECTED AT ALL STUDS CROSSINGVERTICAL OR ANGULAR MEMBERS.SEQUENCING OF WELDS SHALL BE SUCH TO AVOID DISTORTION OF MEMBERS.REPLACE ALL MEMBERS WHICH ARE BURNED THROUGH OR DISTORTED DURINGWELDING OPERATIONS.TEMPORARY BRACING, WHERE REQUIRED, SHALL BE PROVIDED UNTIL ERECTION ISCOMPLETE.RESISTANCE TO BENDING AND ROTATION ABOUT THE MINOR AXIS SHALL BEPROVIDED BY GYPSUM BOARD AND GYPSUM SHEATHING ON EACH FACE PER AISISPECIFICATION, SECTION 5.1 OR HORIZONTAL STRAPS OR COLD ROLLED CHANNELSBRACING SHALL BE PROVIDED AT 5'-0 OC MAXIMUM.MINIMUM SECTIONS FOR CONSTRUCTION (UNLESS NOTED OTHERWISE ON PLANSOR SECTIONS): A) LOAD BEARING WALLS: 600S162-54 B) NON-LOAD BEARING WALLS: 400S162-33 C) TRUSS CHORDS: 600S162-43 D) TRUSS WEB: 400S162-43MINIMUM LOADS: A) EXTERIOR WALLS: 1) TYPICAL - 35 PSF WIND LOAD 2) CORNERS - 45 PSF WIND LOAD 3) DEFLECTION - L/360 TYPICAL 4) DEFLECTION - L/600 FOR STUD BACKUP OF BRICK VENEER B) ROOF TRUSSES: 1) TOP CHORD DEAD LOAD - 15 PSF 2) BOTTOM CHORD DEAD LOAD - 10 PSFDOUBLE VERTICAL STUDS SHALL BE STITCH WELDED TOGETHER ON BOTH FLANGESWITH 1/16" GROOVE WELDS X 1" LONG AT 12" ON CENTER.ALL SHEET METAL SCREWS SHALL PROTRUDE 1/4" MIN THROUGH METAL FRAMING.ALL METAL STUDS SHALL HAVE STIFFENED FLANGES. SEE MANUFACTURER'SSPECIFICATIONS AND RECOMMENDATIONS.ALL CONNECTIONS ARE TO BE SCREWED WITH MINIMUM OF (4) #12-14 SCREWS OREQUIVALENT WELDS AS NOTED.STUDS ARE TO EXTEND DOWN TO FOUNDATION OR OTHER SUPPORT POINTS ASNEEDED.SUBMITTALS:A) SUBMIT SHOP DRAWINGS SHOWING LAYOUT, SPACING, SIZES AND TYPES OF FRAMING, FASTENING, AND ANCHORAGE DETAILS, INCLUDING MECHANICAL FASTENERS. SHOW REINFORCING CHANNELS, OPENING FRAMING, STRAPPING, BRACING, BRIDGING ACCESSORIES AND CONNECTION DETAILS.B) SUBMIT SEALED CALCULATIONS FROM A PROFESSIONAL ENGINEER REGISTERED IN THE FL CALCULATIONS SHALL INCLUDE DATA SHEETS IDENTIFYING MEMBER MANUFACTURER, MEMBER PROPERTIES, DETAILS OF ASSEMBLY, CONNECTION VALUES, AND BRACING.EXISTING CONDITIONSPRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY ALLEXISTING CONSTRUCTION, ELEVATIONS AND CONDITIONS. ANY CONDITIONSDISCOVERED IN VARIANCE WITH DESIGN DOCUMENTS SHALL BE BROUGHTTO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. CONTRACTOR ISRESPONSIBLE FOR PROTECTING ALL EXISTING CONSTRUCTION TO REMAIN.ANY DAMAGE CAUSED BY THE CONTRACTOR SHALL BE REPAIRED ORREPLACED TO THE SATISFACTION OF THE OWNER AND ARCHITECT AT NOCOST TO THE OWNER.ABBREVIATIONS AND STRUCTURAL NOTES07-14-2017CONFORMED SET162
13' - 0"UNKRESTRIC
T
E
DAREAKEEPOUT GENERATORLOADING DOCK AREASCREENING AREAJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S005.dwg Jul 12, 2017 - 2:30pm daranS12014NTS1-S005WIND LOADING TABLES (C&C)1.03-79.01-47.401.03-78.08-46.851.03-75.29-45.171.03-74.36-44.621.03-79.01-47.401.03-78.08-46.851.03-75.29-45.171.03-74.36-44.621.03-130.13-78.081.03-102.25-61.351.03-65.07-39.041.03-37.18-22.311.0346.48-51.12 27.89-30.671.0344.15-48.80 26.49-29.281.0340.43-45.55 24.26-27.331.0338.11-42.76 22.87-25.651.0336.25-40.90 21.75-24.541.0346.48-65.07 27.89-39.041.0344.15-60.42 26.49-36.251.0340.43-53.45 24.26-32.071.0338.11-48.80 22.87-29.281.0336.25-44.15 21.75-26.491.0316.00-46.48 9.60-27.891.0316.00-46.48 9.60-27.891.0316.00-44.15 9.60-26.491.0316.00-41.839.60-25.101.0316.00-83.66 9.60-50.191.0316.00-74.36 9.60-44.621.0316.00-60.42 9.60-36.251.0316.00-51.12 9.60-30.671.0316.00-130.13 9.60-78.081.0316.00-106.89 9.60-64.141.0316.00-74.36 9.60-44.621.0316.00-51.12 9.60-30.67ZONECOEFFICIENTULTIMATE DWPNOMINAL DWPPNET (psf)PNET (psf)WALL PRESSURECOMPONENT AND CLADDINGASCE 7-10 / ULTIMATEROOF PRESSURECOMPONENT AND CLADDINGASCE 7-10 / ULTIMATEZONEEFFECTIVE WINDCOEFFICIENTULTIMATE DWPNOMINAL DWPPNETPNETROOF OVERHANG PRESSURECOMPONENT AND CLADDINGASCE 7-10 / ULTIMATE1101201501100210220250210031032035031004104204504100420051052055051005200110120150110021022025021003103203503100AREAEFFECTIVE WINDAREAZONECOEFFICIENTULTIMATE DWPNOMINAL DWPPNET (psf)PNET (psf)EFFECTIVE WINDAREA1.16-98.40 -59.041.16-97.35-58.411.16-94.21-56.531.16-93.17-55.901.16-98.40-59.041.16-97.35-58.411.16-94.21-56.531.16-93.17-55.901.16-155.98-93.591.16-124.57-74.741.16-82.70-49.621.16-51.29-30.781.1661.76-67.00 37.06-40.201.1659.15-64.38 35.49-38.631.1654.96-60.72 32.97-36.431.1652.34-57.58 31.40-34.551.1650.25-55.48 30.15-33.291.1661.76-82.7037.06-49.621.1659.15-77.4635.49-46.481.1654.96-69.61 32.97-41.771.1652.34-64.38 31.40-38.631.1650.25-59.15 30.15-35.491.1625.12-61.76 15.07-37.061.1622.51-61.76 13.50-37.061.1620.94-59.15 12.56-35.491.1619.89-56.53 11.93-33.921.1625.12-103.64 15.07-62.181.1622.51-93.17 13.50-55.901.1620.94-77.46 12.56-46.481.1619.89-67.00 11.93-40.201.1625.12-155.98 15.07-93.591.1622.51-129.8113.50-77.881.1620.94-93.17 12.56-55.901.1619.89-67.00 11.93-40.20ZONECOEFFICIENTULTIMATE DWPNOMINAL DWPPNET (psf)PNET (psf)ZONEEFFECTIVE WINDCOEFFICIENTULTIMATE DWPNOMINAL DWPPNETPNET1101201501100210220250210031032035031004104204504100420051052055051005200110120150110021022025021003103203503100AREAEFFECTIVE WINDAREAZONECOEFFICIENTULTIMATE DWPNOMINAL DWPPNET (psf)PNET (psf)EFFECTIVE WINDAREAL O A D I N G DO C K WALL PRESSURECOMPONENT AND CLADDINGASCE 7-10 / ULTIMATEROOF PRESSURECOMPONENT AND CLADDINGASCE 7-10 / ULTIMATEROOF OVERHANG PRESSURECOMPONENT AND CLADDINGASCE 7-10 / ULTIMATES C R E E N I N G A R E A NTSPHASE I: WIND LOADING TABLESNNORTH07-14-2017CONFORMED SET163
6" CONCRETE SLAB W/#4@12O.C. EA. WAY CTRD IN SLABOVER 6" COMPACTED GRAVELT/SLABEL. +0'-0" S.J.S.J.S.J.S.J.length = 15ft max.width= 15ft max.(8ft min.)(TYP.)(8ft min.)(TYP.)T/BOND BEAMEL. 5'-4"A12T/SLABEL. +0'-0" T/SLABEL. +0'-0" TRUCK WELLEL. -4'-0" P2P2P2P3CP3CP3CP3CP2P2P2P2P2P2P2P2P2P2P2P2P2P3P2P2P2P2P2P2P2P2P2P218'-0"36'-8"110'-0"2'-0"40'-0"WF2.5WF2.5WF2.5WF2.5WF2.5WF2.5WF2.0WF2.0BCD71-S101 1-S10261-S101 1-S102T/BOND BEAMEL. +5'-4"T/BOND BEAMEL. +5'-4"T/BOND BEAMEL. +5'-4"T/BOND BEAMEL. +5'-4"T/BOND BEAMEL. +5'-4"T/BOND BEAMEL. +3'-4"61-S101 1-S102P2P2P22'-8"2'-8"8'-0"4'-0"6'-0"2'-0"3'-4"12'-8"8'-0"2'-8"3'-4"5'-4"3'-4"2'-8"8'-0"3'-4"8'-0"4'-0"8'-0"4'-0"21-S101 1-S10221-S101 1-S10251-S101 1-S10231-S101 1-S10211-S101 1-S10241-S101 1-S10271-S101 1-S10221-S101 1-S10221-S101 1-S10231-S101 1-S10231-S101 1-S10231-S101 1-S10221-S101 1-S10221-S101 1-S10291-S1011-S10251-S101 1-S10280°3'-4"6'-0"6'-0"3'-4"3'-4"5'-4"P2P2HVAC ACCESSREFER TO MECH. DWGS.SEE DETAIL ON THIS SHEET(TYP. FOR ALL SLABS)TRENCH DRAINSEE CIVIL DWGS. FORADDITIONAL INFORMATIONWF4.5WF4.53'-4"P21'-4"11-S101 1-S1028'-0"10'-8"8'-0"4'-0"P28'-0"9'-4"(FS)(FS)WF5FELT BOND BREAKERNOTE:LOCATE JOINTSAS SHOWN ONFOUNDATION PLANT/2T/212" OF COMPACTEDSUBGRADE#6 SMOOTH DOWEL 18"LG AT 18"O.C.SUPPORT ON WIREBASKET SUPPORTSFIRST SUPPORT TO BELOCATED 2'-0" FROMCONTROL JOINTINTERSECTIONST/4TSOFTCUT W/"SOFTSAW"1/4" MAX12" OFCOMPACTEDSUBGRADE1. EXTERIOR WALLS2. INTERIOR LOAD BEARING WALLS3. INTERIOR PARTITION WALL CORNERS AND JAMBS4. INTERIOR NON-LOAD BEARING WALLS WHERE NOTED ON PLANMASONRY WALL REINFORCING DETAILSSHOWN ON TYPICAL EXTERIOR WALLFOOTING SHALL APPLY TO ALL OF THEFOLLOWING:(UNLESS NOTED OTHERWISE)AT EACHJAMB (TYP.)AT WALLCORNERVERTICALREINFORCING8" CMU#5 @ 40" O.C.MASONRY WALL SCHEDULESYMBOL THICKNESSREINFORCING8" CMU#5 VERTICAL @ EACH CELL GROUTED SOLID.WALL SEGMENTS SHALL BE REINFORCED WITH 9 GA. GALVANIZED LATERAL REINFORCING @16" O.C. HORIZONTAL. EXTEND REINFORCING 6" INTO POURED ELEMENTS AND AROUNDENCASED STEEL.NOTES:1. ADJACENT TO ANY EXTERIOR WALL OPENING, PROVIDE 8" X 16" FULLY GROUTED CMU PIERW/ (1) #5 EACH CELL FULL HEIGHT.2. ALL MASONRY REINFORCED CELLS SHALL BE FILLED WITH 3000 PSI GROUT MIX.WF2.52'-6"(3) #5 CONT.FOOTING SCHEDULEMARK WIDTHREINF.JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S101.dwg Jul 12, 2017 - 2:30pm daranS12014LOADING DOCKBUILDINGORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANTERMINALADDITIONWEST1'-4""t"VERTICALHORIZONTALP2P3(2) #5(1 EACH CELL)REINFORCEMENTPLAN DIMENSIONSMARKMASONRY PILASTER SCHEDULE(1 EACH CELL)(3) #5SEE ENGINEERING NOTES ANDSECTIONS & DETAILSSEE ENGINEERING NOTES ANDSECTIONS & DETAILS1/4" =1'-0" 1/4" = 1'-0"FOUNDATION PLANN
NORTHLOADING DOCK BUILDING FOUNDATIONPLAN1'-4"1'-4"P3C(1 EACH CELL)(3) #5SEE ENGINEERING NOTES ANDSECTIONS & DETAILS2'-0""t"WF2.02'-0"(2) #5 CONT.1-S101FIRST FLOOR TOP OF SLAB REFERENCE = 0'-0". 0'-0" IS FORREFERENCE ONLY. SEE CIVIL FOR NVGD ELEVATION.TOP OF FOOTINGS @ EL. (-2'-4") MIN. BELOW TOP OF SLABUNLESS NOTED OTHERWISE. BOTTOM OF FOOTING SHALLBE 16" MIN. BELOW ADJACENT FINISH GRADE. VERIFY ALLTOP OF FOOTING ELEVATIONS W/ ARCHITECTURALDRAWINGS PRIOR TO FABRICATION AND CONSTRUCTION.2.1. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOTSHOWN. VERIFY ALL DIMENSIONS W/ ARCHITECTURALDRAWINGS PRIOR TO CONSTRUCTION.3.SEE ARCHITECTURAL AND MECHANICAL DRAWINGSFOR ALL SLEEVES, PIPES, INSERTS AND EMBEDDEDITEMS.4.5.FOUNDATION PLAN NOTESFLOOR CONSTRUCTION: 5" CONCRETE FLOOR SLAB (f'c=4,000PSI) W/6x6, W1.4xW1.4 W.W.F. OR 1-1/2 LBS OF POLYPROPYLENEFIBERMESH PER CU. YD. OF CONCRETE ON 10 MIL VAPORBARRIER ON PREPARED SUBGRADE PER GEOTECHNICALREPORT. SEE ARCHITECTURAL FOR EXTENTS.6.WALLS ARE TO BE REINFORCED MASONRY WALLS. SEESCHEDULE AND SECTION FOR DETAILS.FOUNDATION LEGENDFX.0 DENOTES ISOLATED FOUNDATION TYPE. REFER TO SCHEDULE FOR DIMENSIONS AND REINFORCEMENT.WFX.0 DENOTES CONTINUOUS WALL FOUNDATION. REFER TO SCHEDULE FOR DIMENSION AND REINFORCEMENT.CFX.0 DENOTES ISOLATED COMBINATED FOUNDATION. REFER TO SCHEDULE FOR DIMENSION AND REINFORCEMENT.CJ DENOTES CONTRUCTION JOINTS.SCX DENOTES STEEL COLUMN. REFER TO SCHEDULE FOR SIZES AND GRADES.1N.T.S.CONTROL JOINT DETAILTYP. SLAB ON GRADE N.T.S.CONST. JOINT DETAILTYP. SLAB ON GRADE END OF MASONRY WALLNOT TO SCALEREINFORCING DETAIL ATWF4.51'-0" MIN.4'-6"(8) #5 CONT. #5 @ 12" O.C. TRANSV. REINF.DEPTHREMARKS1'-4" MIN.1'-4" MIN.#5 @ 10" O.C. TRANSV.#5 @ 10" O.C. TRANSV.07-14-2017(FS) DENOTES FOOTING STEP. REFER TO DETAIL 1/1-S102.(U.N.O.)WF51'-4" MIN.5'-0"(8) #5 CONT. #5 @ 12" O.C. TRANSV. REINF.10" CMU#6 @ 16" O.C.CONFORMED SET164
REF SLAB PLANFOR SLAB REINFREF FDN PLANFF ELVARIES11#3 AT 12" OC8'-0"2'-0"1'-8"2'-0"2'-0"2'-0"1'-8"(3) #4 CONT WITHCORNER BARS#3 AT 12" OC EW2" CLRSEE ARCH(PIT WIDTH)* VERIFY PIT WIDTH WITHEDGE LEVELERMANUFACTURER8/1-S102SLOPE 1/2"2'-0"SEE ARCH DRAWINGS112" CLR1'-8"8"#3x4'-0" DOWELS AT12" OC2'-0"#3 AT 12" OC EWCMU WALLBEYONDBUMPER PADREF ARCH1'-712"(3) #4 CONT WITHCORNER BARSL3x3x1/4 WITH 1/2" DIA x 0'-4"HSA AT 18" OC TOOL JOINTAT EDGE OF ANGLE TYPREF FDN PLAN FF EL #3 AT 12" OC2" CLR1'-8"2'-0"2'-0"512"11REF SLAB PLANFOR SLAB REINFNOTE:CONTRACTOR TO STITCH WELD DOCKLEVELER TO FRAME ANGLES PERMFR REQUIREMENTS.WATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENTSEE SCHEDULE FORREINFORCEMENTTOP OF SLABREF. ELEVATION = 0'-0"3/4"3/4"CLR.CLR.STD. ACI HOOKSEE SCEDULEMIN.EMBED.3"3"3"8"1'-4"COMPACTED FILL, SEEENG. NOTES SHT.1-S003SEE FOUNDATIONPLAN FOR MIN.REINFORCEMENT16"PROVIDE (1) #4 HOOK BAR OVER (1)#5 CONT. BAR SPACED @ 12" O.C.5" REINF. CONCRETE SLAB-ON-GRADE,SEE PLAN FOR REINFORCEMENT.24" MIN. LAP SPLICEREF. ELEV.= -1'-4" MIN.TOP OF FOUNDATIONSOLID GROUTED LINTLE TIE-BEAM(BOND-BEAM) WITH (1) #4 CONT. EVERY48" FROM BOTTOM TO TOP OF CMU WALLPROVIDE HORIZONTAL JOINT REINFORCINGFOR ALL MASONRY CONSTRUCTION. USE 9GAGE, GALVANIZED, LADDER TYPEREINFORCING CONFORMING TO ASTM A82,SPACED VERTICALLY AT 16" O.C. MAX.HORIZONTAL REINFORCEMENT (OPTION #2)HORIZONTAL REINFORCEMENT (OPTION #1)8"8" CMU WALLS SEE PLAN FORREINFORCING, SHT. 1-S1018" CMU STEM-WALL SEE PLANFOR REINFORCING, SHT. 1-S101VAPOR BARRIERTRUCK WELL SECTION3/4"3/4"CLR.CLR.2'-6"MIN.EMBED.3"3"3"1'-0"1'-4"SEE FOUNDATIONPLAN FOR MIN.REINFORCEMENT16"PROVIDE (1) #4 HOOK BAR OVER (1) #5CONT. BAR SPACED @ 12" O.C.REF. ELEV.= -6'-0" MIN.TOP OF FOUNDATIONVAPOR BARRIERSOLID GROUTED LINTLE TIE-BEAM(BOND-BEAM) WITH (1) #4 CONT. EVERY48" FROM BOTTOM TO TOP OF CMU WALLPROVIDE HORIZONTAL JOINT REINFORCINGFOR ALL MASONRY CONSTRUCTION. USE 9GAGE, GALVANIZED, LADDER TYPEREINFORCING CONFORMING TO ASTM A82,SPACED VERTICALLY AT 16" O.C. MAX.HORIZONTAL REINFORCEMENT (OPTION #1)HORIZONTAL REINFORCEMENT (OPTION #2)8" CMU WALLS SEE PLAN FORREINFORCING, SHT. 1-S101.8X8 CONC. THICKENEDEDGE W/ (1) #5 CONT. BAR8"REF GENERAL NOTES FORTRUCK DOCK SLABTOP OF SLABREF. ELEV.= -4'-0"REF. ELEVATION = 0'-0"TOP OF MAIN SLAB5" REINF. CONCRETE SLAB-ON-GRADE,SEE PLAN FOR REINFORCEMENT.PFJ AND SEALANTREF ARCHBUMPER PAD REF ARCH1/2"x1'-0"x1'-4" GALVANIZEDPLATE WITH (4) 1/2" DIA x0'-4"HSA EACH SIDE OF DOORCONCRETE WALL WITH#5 @ 12" O.C. VERTICAL WITH#4 @ 12" O.C. HORIZONTALWATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFI OREQUIVALENT5" REINF. CONCRETE SLAB-ON-GRADE,REF. TO PLAN FOR REINFORCEMENTREF. ELEV.= 0'-0" MIN.TOP OF FOUNDATIONCOMPACTED FILL, SEE GEN.NOTES ON SHT. 1-S003VAPOR BARRIER5"11"1'-0"11"11"SEE SCHEDULE FORREINFORCEMENT30" MIN. LAP SPLICEPROVIDE HORIZONTAL JOINT REINFORCINGFOR ALL MASONRY CONSTRUCTION. USE 9GAGE, GALVANIZED, LADDER TYPEREINFORCING CONFORMING TO ASTM A82,SPACED VERTICALLY AT 16" O.C. MAX.8" REINFORCED SOLID GROUTED MASONRYSTEM-WALL PROVIDE (1) #4 AT 16" O.C. MAX.AND (3) #5 AT ALL CORNERSSAME ASFTG. REINF.MAXIMUM STEP RATIO: 1 VERTICAL TO 2 HORIZONTALNOTE: FOOTING THICKNESS VARIES. DETAIL FOR INFORMATION ONLY. SEEPLANS FOR FOOTING SIZE AND THICKNESS.dFTG. REINF.2d (MIN)STD.LAPFTG.DEPTH6" MAX.d(2'-0"MAX.)STD.LAPFTG.DEPTH(1'-4" MIN.)OC G#5 @ 12" 0.C.1'-0"#5 @ 12" 0.C.8"2'-4" MINIMUM#5 AT 12"OC6'-0" MAX2X KEYCONTIN.4'-6"#5 @ 12" 0.C.2'-6"12"#5 @ 12" 0.C.#4 AT 12"O.C.#5 @ 12" 0.C.MIN2'-0"MINGUARDRAIL-SEE ARCHWATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENT3'-0"5'-0" (UON)TYP BOLLARD HEIGHT16" DIA CONC AT 4" POST24" DIA CONC AT 6" POST14" LONG #6 REBARS (4 EACHPOST)2"5'-0" MINGRADE LEVELSLOPE TO GRADE4" DIA CONC FILLED STEELGUARD POST, PAINTEDYELLOW W/ SMOOTH CROWNON TOP6" DIA CONC FILLED STEELGUARD POST, PAINTEDYELLOW W/ SMOOTH CROWNON TOPSEE ARCHITECTURALDRAWINGS FOR WALLCOMPOSITION ABOVEAND BELOW GRADEFINISHED FLOORSEE ARCHT'L DWGS.FOR THRESHOLDNOTES:1. SLAB TO BE 5" MINIMUM (INCLUDING FORM). FORM TO BE 1 1/2"GALVANIZED STEEL FORM DECK2. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS, SLOPE, ANDDEPRESSION OF SLAB.JAMB BEYONDXXXREF.SCHED.SEE TYPICAL EXTERIORWALL FOOTING DETAIL#4@10"SEE ARCHITECTURALDRAWINGS FOR WALLCOMPOSITION ABOVEAND BELOW GRADEFINISHED FLOORSEE ARCHT'L DWGS.FOR THRESHOLDJAMB BEYONDXXXSEE ARCHSIDEWALKRE: CIVILFIN FLR ELEVRE: ARCHPREMOLDEDREF. SCHEDULE15'-4" AFFTOP OF CMUCONCRETESLAB - SEECIVIL12" CMU BLOCKPROVIDE HORIZONTAL JOINTREINFORCING FOR ALL MASONRYCONSTRUCTION. USE 9 GAGE,GALVANIZED, LADDER TYPE REINFORCINGCONFORMING TO ASTM A82, SPACEDVERTICALLY AT 16" O.C. MAX.DOUBLE BOND BEAMW/(2)#5 CONT.2'-6" MIN. SPLICE12" BOND BEAMW/(1)#5 CONT.12" BOND BEAMW/(1)#5 CONT.10" CMU WALL. REFERTO MARONRY WALLSCHEDULE FOR REINF.4'-0"LINTEL SPAN4'-0"16" MIN. BRG.8" MIN. BRG.PRECAST LINTELOF PRECAST LINTELTO ALLOW PASSAGEPROVIDE HOLES IN BOTTOF VERTICAL STEEL(2) #5 HORIZONTAL CONT.ADD THIRD #5 VERTSOLID GROUTED CELL@ OPENINGS > 10'#5 VERT CENTERED IN1-#5 CONT.OPENINGS > 8' ONLYADD 2ND LAYER OFSTEEL @ EXTERIOR1-#5 CONT.OPENINGS GREATER THAN 8'-0"OPENINGS 8'-0" OR LESSALL DOWNCELLSSHOULD LINE UPTO FORM A CONTINUOUSGROUTED CELL FROMFOUNDATION TO TIE-BEAM.KEEP ALL MIS-ALLIGNEDCELLS WITHIN 4FT.OF MIDDLE-SECTIONOF WALL.(1) #5 HORIZONTALCONT.PROVIDE LINTEL BLOCK(U-BLOCK) ASREQUIREDPROVIDELINTEL BLOCK(U-BLOCK)AS REQUIREDPROVIDE LINTEL BLOCK(U-BLOCK) ASREQUIREDPROVIDE LINTEL BLOCK(U-BLOCK) ASREQUIREDEXTENDHORIZONTALSTEEL INTOWALL, FULLYGROUTEDEXTENDHORIZONTALSTEEL INTOWALL, FULLYGROUTEDPROVIDE HOLES INBOTT OF PRECASTLINTEL TO ALLOWPASSAGE OF VERTICALSTEEL#5 VERT INSOLID GROUTEDCELLJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S102.dwg Jul 12, 2017 - 2:30pm daranS120141/4" =1'-0"LOADING DOCK BUILDING FOUNDATIONSECTIONS & DETAILS1-S102FOOTING DETAILSCALE: 1/2" =1'-0"51-S102TYP. STEPPEDTYP. BOLLARD DETAILSCALE: 1/2"=1'-0"TYPICAL SLAB DETAILSCALE: 1/2" =1'-0"21-S102TYPICAL SLAB DETAILSCALE: 1/2" =1'-0"11-S102SECTIONSCALE: 3/4" =1'-0"31-S102TRUCKWELL SECTIONSCALE: 3/4" =1'-0"41-S102SECTIONSCALE: 3/4" =1'-0"61-S102DOCK LEVELER PITSCALE: 3/4" =1'-0"71-S102SIDE OF DOCK LEVELERSCALE: 3/4" =1'-0"81-S102TYP. STEPPEDFOOTING DETAILSCALE: 1/2"=1'-0"SECTIONSCALE: 3/4" =1'-0" @SECURITY WALL91-S10207-14-20173/4" = 1'-0"TYPICAL MASONRY WALL OPENINGCONFORMED SET165
10'-3" CLEAR8"8"5'-1"8"8"8'-2" CLEAR8"3'-8"13'-1034"8"8"EXISTING BUILDING(-5'-0")(-5'-0")(-5'-0")(-5'-0")(-2'-4")(-2'-4")31-S103 1-S10361-S103 1-S103ELEV.PIT51-S103 1-S103± 6'-9" (V.I.F.)EXISTING STEEL COLUMN RELOCATEDUP41-S103 1-S103SUMPPIT81-S103 1-S103EXIST. COL.F3EXIST. COL.F4EXIST. COL.F4EXIST. COL.F4EXISTINGSTEEL STAIRRELOCATED2625D2-#5 CONT.0'-0"F.F. ELEVF.F. ELEV. = 0'-3"ELEVATOR ROOM8'-2" CLEAR8"5" SLAB-ON-GRADEW/6x6-W2.1xW2.1 W.W.F.#4 @12" O.C.8" CMU W/ #5BARS @ 24" O.C.8" CMU W/#5BARS @ 24" O.C.8" CMU W/#5BARS @ 24" O.C.#5 @12" O.C.8"8"2'-0"5"3"#5 DOWEL@ 24" O.C.#5 DOWEL@ 24" O.C.1'-0" (TYP)1'-0"CONT. BONDBREAKER12" OF COMPACTEDSUBGRADE(2) #5 BARS TOPAND BOT. (TYP.)#6@12" O.C. E.W. TOPAND BOTTOM#5 @12" O.C.1'-0"#5 @12" O.C.1'-0"ELEV.= (-5'-0")ELEVATOR PIT2'-6" TYP.(-5'-0")F.F. ELEVATOR PIT#5@12" O.C. E.F.(2) #5 BARS TOPAND BOT. (TYP.)#5 @24" O.C.8"#4@12" O.C. E.F.#3 @ 12" O.C.#5@12" O.C. E.F.#4@12" O.C. E.F.1'-0"WATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENTWATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENT(2) #5 BARS TOPAND BOT. (TYP.)#4 @12" O.C.5" SLAB-ON-GRADEW/6x6-W2.1xW2.1 W.W.F.8"12" OF COMPACTEDSUBGRADEELEV.=0'-0"F.F. ELEV.1'-6" MIN.8"8"8"8"8"10'-3" CLEAR8"#4 @12" O.C.5" SLAB-ON-GRADEW/6x6-W2.1xW2.1 W.W.F.1'-0" (TYP)1'-0"ELEV.=0'-0"F.F. LELEV.DAMP-PROOFING (TYP)8"2'-6" TYP.12" OF COMPACTEDSUBGRADE8" CMU W/ #5BARS @ 24" O.C.#5 DOWEL@ 24" O.C.1'-0"#5 @12" O.C.1'-0"2'-6" TYP.1'-0"(2) #5 BARS TOPAND BOT. (TYP.)#5 @12" O.C.1'-0"(-5'-0")F.F. ELEVATOR PIT#5@12" O.C. E.F.#4@12" O.C. E.F.#6@12" O.C. E.W. TOPAND BOTTOM#5@12" O.C. E.F.#4@12" O.C. E.F.WATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENTWATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENT2'-0"2'-0"#6@12"1'-0"1'-0"8"1'-0"#6@12"8" CMU W/#5@24"O.C.MORTARFILL CELLS#5@24"O.C.DOWELSELEV.=(-5'-0")ELEVATOR PIT2'-6" MIN. SPLICEELEV.=0'-0"F.F. LELEV.1'-0"1'-0"ELEV.=(-7'-0")SUMP PIT(2) #5 BARS TOPAND BOT. (TYP.)#5 @12" O.C.#6@12" O.C. E.W. TOPAND BOTTOM#5@12" O.C. E.F.#4@12" O.C. E.F.WATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENT7'-734" CLEAR8"8"8"8'-4" CLEAR8"4'-1034" (V.I.F.)ELEV.PITEXISTING BUILDING101-S103 1-S10471-S103 1-S103± 11'-0" EXISTING FOOTING (V.I.F.)± 11'-0" EXISTING FOOTING (V.I.F.)EXISTING STEELCOLUMN (V.I.F.)91-S103 1-S103(-5'-0")(-5'-0")(-5'-0")111-S103 1-S10413J8"ELEV.=0'-0"F.F. LELEV.12" OF COMPACTEDSUBGRADE8" CMU W/ #5BARS @ 24" O.C.#5 DOWEL @ 24" O.C.(-1'-8") EXISTING FOOTINGF.F. ELEV. (V.I.F.)(-5'-0")F.F. ELEVATOR PITEXISTINGCONCRETE SLAB7'-734" CLEARELASTOMERICJOINT1'-0"#5 @12" O.C.1'-0"#5 @12" O.C.1'-0"5'-0"2'-6" TYP.2'-6" TYP.(2) #5 BARS TOPAND BOT. (TYP.)#5@12" O.C. E.F.#4@12" O.C. E.F.#5@12" O.C. E.F.#4@12" O.C. E.F.#6@12" O.C. E.W. TOPAND BOTTOMNOTE: CONTRACTOR MUST PROVIDETEMPORARY SHORING TO AVOIDUNDERMINING OF EXISTING FOOTINGWATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENT#5 @24" O.C.5" SLAB-ON-GRADEW/6x6-W2.1xW2.1 W.W.F.4"MIN.4"MIN.8"2'-0"8"ELEV.=0'-0"F.F. LELEV.2'-6" TYP. SPLICE8" CMU W/ #5BARS @ 24" O.C.8"1'-0"4 #4 CONT.#5 @ 12" O.C.EPOXYEMBEDDED 4" MIN.#4 @12" O.C.12" OF COMPACTEDSUBGRADE#4 @ 12"8"8"8"2'-0"(2) #5 BARS TOPAND BOT. (TYP.)#5 @12" O.C.2#5 CONT.1'-0"2'-4"JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S103.dwg Jul 12, 2017 - 2:30pm daranELEVATOR SHAFT STRUCTURAL PLAN ANDFOOTING SECTIONSS12014AS SHOWN1-S1031/4" = 1'-0"1LOADING DOCK ELEVATOR - FOUNDATION PLANELEVATOR PIT SECTION3 3/4" = 1'-0"SECTION4 3/4" = 1'-0"ELEVATOR PIT SECTION6 3/4" = 1'-0"SUMP PIT SECTION8 3/4" = 1'-0"2ELEVATOR NO.4 - FOUNDATION PLAN1/4" = 1'-0" @TERMINAL "B"ELEVATOR PIT SECTION9 3/4" = 1'-0"SECTION5 3/4" = 1'-0"SECTION7 3/4" = 1'-0"07-14-2017CONFORMED SET166
8"8'-4" CLEARELEV.=0'-0"F.F. LELEV.ELASTOMERICJOINT8" CMU W/ #5BARS @ 24" O.C.#5 DOWEL @ 24" O.C.EXISTINGCONCRETE SLAB1'-0"#5 @12" O.C.1'-0"#5 @12" O.C.1'-0"2'-6" TYP.2'-6" TYP.(2) #5 BARS TOPAND BOT. (TYP.)(2) #5 BARS TOPAND BOT. (TYP.)1'-0"1'-0"1'-0"ELASTOMERICJOINT8"EXISTINGCONCRETE SLAB(-5'-0")F.F. ELEVATOR PIT#6@12" O.C. E.W. TOPAND BOTTOM#5@12" O.C. E.F.#4@12" O.C. E.F.#5@12" O.C. E.F.#4@12" O.C. E.F.WATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENTWATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENT8"ELEV.=0'-0"F.F. LELEV.ELASTOMERICJOINT#5 @12" O.C.1'-0"(2) #4 BARS TOPAND BOT. (TYP.)1'-0"1'-0"EXISTINGCONCRETE SLAB(-5'-0")F.F. ELEVATOR PIT#5@12" O.C. E.F.#4@12" O.C. E.F.#6@12" O.C. E.W. TOPAND BOTTOM4"MIN.1'-6"WATERPROOFINGMEMBRANE SUCH ASMIRADRAIN BY MIRAFIOR EQUIVALENTEPOXYEMBEDDED 4" MIN.(6) #4 CONT AT DRAINCL OF TRENCHDRAIN ANDTHICKENED SLAB#4 AT 16" O.C. W/ ACI STDHOOKS1'-0"TYPDEPTH OFTRENCH DRAIN+6" MINWIDTH OFTRENCH DRAIN+1'-0" MIN3"CLR3"CLR3"CLRNOTE: REF ARCH FORLOCATIONS WHERE SLABSLOPES TO DRAINSLOPESLOPE12" WIDE METAL TRENCH DRAINBY ZURN MODEL Z882PERMA-TRENCH OR ENGINEERAPPROVED EQUAL4'-0"FROM FACE OF LOADING DOCK WALLEND BLOCKTO ROOFCONC. MORTAR1#4 FOOTINGMASONRY WALLS#5@40"O.C.RODS Ø 3/16" CROSS ROD #9 MIN LAP 6"#5@40"O.C.HEAVY DUTY HORIZONTAL TRUSSREINF.SUCH AS ``DUR-O-WAL'' EVERYOTHER COURSE TRUSS TYPE, SIDE2#4 CONT.RODS Ø 3/16" CROSS ROD #9 MIN LAP 6"OTHER COURSE TRUSS TYPE, SIDEREINF.SUCH AS ``DUR-O-WAL'' EVERYHEAVY DUTY HORIZONTAL TRUSS2#4 CONT.#5@40"O.C.CEMENT MORTARGROUT#5@40"O.C.CORNERS30Øb(2'-0"MIN)TYPICALBARS SAME SIZE &SPACING ASADJACENT BARSINTERSECTIONS30Øb(2'-0" MIN)TYPICAL6Øb TYP.3" MIN.6Øb TYP.(3" MIN.)NOTE: INSTALL BELOW UPPER LAYEROF SLAB REINFORCING3'-6"(2)#4(CTR ON CORNER)SEE NOTE ABOVE1111112"6"SEE PLAN FOR ADD'LSLAB REINF.SLAB EDGE(2)#4 X 2'-0"(CTR ON CORNER)SEE NOTE ABOVE6"6"JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S104.dwg Jul 14, 2017 - 7:32am daranELEVATOR SHAFT FOOTING SECTIONSS12014AS SHOWN1-S104ELEVATOR PIT SECTION10 3/4" = 1'-0"ELEVATOR PIT SECTION11 3/4" = 1'-0"07-14-2017MANSONRY WALLS MASONRY BLOCK WALLTIE COLUMN FOR CORNER OF TYPICAL DETAILS AT SIDES OF DOORSAND AT ENDS OF BLOCKS WALLSHORIZONTAL REINF.TRENCH DRAIN DETAIL12 3/4" = 1'-0"CORNER BAR DETAIL 3/4" = 1'-0"SLAB CORNER REINF. DETAIL 3/4" = 1'-0"CONFORMED SET167
COLCOLCOLCOLCOLCOL122'-0" (V.I.F.)6'-0" (V.I.F.)2'-6" (V.I.F.)EXISTING BUILDINGINTERIOR FACILITIES21(V.I.F.)EXISTING DOOR OPENINGCOLCOLCOLCOLCOLCOLCOLCOLCOL20'-0" (V.I.F.)3'-6" (V.I.F.)11" (V.I.F.)CC1CF6.22CC1CF6.22F.F.ELEV.0'-0"18'-0" NEW ROUGH OPENING (V.I.F)2'-0"2'-0"22'-0"9'-4" NEW ROUGH OPENING (V.I.F)2'-0"2EXISTING CMU WALLASSEMBLY TO REMAINEXISTING CONCRETESLAB TO BE DEMOLISHEDDEMOLITION LEGENDEXISTING WALL TO BEDEMOLISHED1DEMOLITION KEY NOTES2EXISTING CONCRETESLAB TO BE DEMOLISHED.EXISTING PARTIAL CMUWALL TO BE DEMOLISHED.DEMOLITION NOTESA. THE INTENT OF THE DEMOLITION PLANS IS TO SHOW THEGENERAL NATURE OF THE DEMOLITION SCOPE. THE GENERALCONTRACTOR IS RESPONSIBLE FOR VISITING THE JOB SITEAND VERIFYING THE EXISTING CONDITION. THE GENERALCONTRACTOR SHOULD NOTIFY THE ENGINEER IMMEDIATELYOF ANY DISCREPANCIES.B. COORDINATE AND VERIFY WITH THE OWNER ALL ITEMS TO BESALVAGED PRIOR TO DEMOLITION. THESE ITEMS MAYINCLUDE, BUT NOT LIMITED TO, THE FOLLOWING:1 ) GENERATOR FUEL LINES2) GENERATOR POWER SUPPLY CONDUITS AND WIRING.3) GENERATOR SWITCH CONDUITS AND WIRING.C. GENERAL CONTRACTOR IS TO MAINTAIN A SEPARATIONBETWEEN AREAS WITHIN THE SCOPE OF WORK AND AREASOUTSIDE OF THE SCOPE OF WORK BY PROVIDING PLASTICSHEATHING BETWEEN CONTIGUOUS SPACES AND/ORTEMPORARILY TAPING OF JOINTS AND GAPS TO PREVENTDUST MIGRATION.D. CAUSE NO DAMAGE TO EXISTING CONSTRUCTION TO REMAIN.TAKE CARE NOT TO ENCROACH ON ADJACENT OCCUPIEDAREAS OR AREAS NOT WITHIN THE SCOPE OF WORK.PROTECT ALL EXISTING FINISHES, DOORS, FRAMES, ETC.WHICH ARE TO REMAIN.E. CONDUCT DEMOLITION OPERATIONS & THE REMOVAL OFDEBRIS TO ENSURE MINIMUM INTERFERENCE WITH STREETS,WALKS, & OTHER ADJACENT OCCUPIED OR USED FACILITIES.COMPLY WITH LOCAL JURISDICTION REQUIREMENTS FORRECYCLING AND TREATMENT OF ITEMS TO BE RECYCLED.F. DISPOSE OF ALL DEMOLISHED OR REMOVED MATERIALSLEGALLY OFF THE SITE. COMPLY WITH ALL LOCAL HAULING &DISPOSAL REQUIREMENTS.G. THE ENGINEER HAS NO KNOWLEDGE OF AND SHALL NOT BEHELD LIABLE FOR ANY ASBESTOS OR OTHER HAZARDOUSMATERIALS ON JOBSITE. THE CONTRACTOR SHALLIMMEDIATELY ISOLATE THE AFFECTED AREA IF ASBESTOS OROTHER HAZARDOUS MATERIAL ARE DISCOVERED DURINGCONSTRUCTION. NOTIFY OWNER FOR FURTHER INSTRUCTIONBEFORE PROCEEDING WITH OTHER WORK.H. MAINTAIN EXISTING UTILITIES TO REMAIN IN SERVICE ANDPROTECT AGAINST DAMAGE DURING DEMOLITION OPERATIONS.I. SCHEDULE ALL SERVICE SHUT-DOWN(S) WITH THE OWNER.NOTIFY OWNER A MINIMUM TIME OF ONE (1) WEEK ANDADDITIONALLY ONE (1) HOUR PRIOR TO SHUT-DOWN(S).J. REMOVE ALL ABANDONED ANCHOR BOLTS & EMBEDDED ITEMSIN CONCRETE FLOORS THAT PROTRUDE ABOVE THECONCRETE FLOOR SURFACE.K. UPON COMPLETION, CLEAN THE ENTIRE AREA OF DEMOLITIONTO A TIDY, UNIFORM CONDITION REMOVING ALL DEBRIS, DUSTPARTITIONS & ASSOCIATED MATERIALS USED DURING THEDEMOLITION. CLEAN ALL AREAS IMPACTED BY THEDEMOLITION, INCLUDING BUT NOT LIMITED TO, ADJACENTOCCUPIED AREAS AND AREAS NOT WITHIN THE SCOPE OF WORK.L. ABANDONING ITEMS OR UNUSED UTILITIES IN PLACE IS STRICTLY PROHIBITED, UNLESS SPECIFICALLY PERMITTED BY THE OWNER.M. PATCH / PAINT / FINISHES:TAPE, PATCH, SAND SMOOTH, AND PAINT ALL EXISTINGINTERIOR WALLS WHERE DAMAGED TO UPGRADE TOCLIENT-ACCEPTED CONDITION. ALL ADJACENT EXISTINGFINISHES DAMAGED OR AFFECTED BY DEMOLITION ORCONSTRUCTION OF NEW AREAS IN SCOPE OF WORK SHALLBE PATCHED AND REPAIRED TO MEET CLIENT SATISFACTION.N. COMPLY WITH ALL STANDARD LOCAL, NATIONAL, STATE ANDFEDERAL SAFETY REQUIREMENTS FOR DEMOLITION.O. EXISTING STEEL SHALL BE TREATED FOR CORROSION WHEREVISIBLE SIGNS OF CORROSION EXIST.P. THE CONTRACTOR SHALL TAKE CARE WHEN REMOVING EXISTING MASONRY WALLS AND CONCRETE AT LOCATIONS WHERE ROOFJOISTS, BRIDGING AND BRACING PASS THROUGH THE EXISTING MASONRY WALLS AND CONCRETE. THE USE OF SAW CUTTING AND HAND TOOLS MUST BE USED TO PREVENT DAMAGE TO EXISTING ROOF FRAMING.Q. COORDINATE LOCATION OF MASONRY WALL OPENINGS WITH ARCHITECTURAL DRAWINGS. JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S105.dwg Jul 12, 2017 - 2:30pm daranBAGGAGE CLAIM NO.3 EXISTING WALLDEMOLITION & PROPOSED FOUNDANTION PLANTERMINALADDITIONWESTBAGGAGECLAIM NO.3ORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLAN1-S105 1/8" = 1'-0"BAGGAGE CLAIM NO.3 EXISTING WALL DEMOLITION NNORTH107-14-2017AS SHOWNS12014 1/8" = 1'-0"BAGGAGE CLAIM NO.3 FOUNDATION PLAN NNORTH2 1/4" = 1'-0"BAGGAGE CLAIM NO.3 EXISTING WALL DEMOLITION 3PLAN VIEWELEVATION VIEWCONFORMED SET168
CC1 REF TOPLAN & SCHED.F.F.ELEV.0'-0"T/FOOTING-2'-4" COLCOL8#6 BOTTOM8#6TOP#3 @ 10" O.C. E.W.26#6 TOP& BOTTOM31-S106T/CONC. BEAM11'-4"CB1 REF TO SCHED.#3@10" O.C. STIRRUPSCOMPACTED FILL95% PROCTOR10 MIL VAPORBARRIERREF: PLANCOLCOLCOL8#6 BOTTOM8#6 TOP26#6 TOP & BOTTOMT/FOOTINGELEV= (-2'-4") 22'-0"6'-0"3'-0"21-S106CC1CF1COLF.F.ELEV.0'-0"T/FOOTING-2'-4" T/CONC. BEAM11'-4"9'-4"CB12'-0"EXISTING CWM WALLASSEMBLY OVER CONC.BEAM TO REMAINREF. SCHED.COMPACTED FILL95% PROCTORREF: PLAN4"MIN.4"MIN.EPOXYEMBEDDED 4" MIN.10 MIL VAPORBARRIERJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S106.dwg Jul 12, 2017 - 2:31pm daran1-S106 1/4" = 1'-0"COMBINED FOOTING (CF6.22) PLAN107-14-2017AS SHOWNS12014 1/4" = 1'-0"SECTION2 1/4" = 1'-0"SECTION3MARKVERTICALREMARKSCC18 #8N/ATIES#3 @ 10" O.C.CONCRETE BEAM SCHEDULEMARK DIMENSIONSTOPCB124" X 24" CONT.4#7BOTTOM TIES4#5#3 @ 10" O.C.MIDDLE4#724"24"CONCRETE COLUMN SCHEDULEWIDTHMARKDEPTH LONG DIRECTION REINF.LENGTHCF6.226'-0" 22'-0" 1'-4"8 #6 O.C. TOP & BOTTOM COMBINED FOOTING SCHEDULEBAGGAGE CLAIM NO.3 WALL OPENINGSTRUCTURAL REINFORCEMENT24"24"DIMENSIONS26 #6 O.C. TOP & BOTTOM SHORT DIRECTION REINF.CONFORMED SET169
4'-0"12'-6"4'-0"12'-6"4'-0"35'-3"1'-0"15'-6"1'-0"16'-3"1'-0"1'-0"31-S108CONCRETE ISLAND.CURB, REFER TO CIVIL.F60F60F60F60F60F606" CONCRETE SLAB ON GRADE W/ 6X6,W1.4 X W1.4 WWF OR 1-1/2 LBS OFPOLYPROPYLENE FIBERMESH PER CU.YD. OF CONCRETE ON 10 MIL VAPORBARRIER ON PREPARED SUBGRADEPER GEOTECHNICAL REPORT. SEEARCHITECTURAL FOR EXTENTS.CONTROL JOINT SEE5-1-S108 FOR DETAILS(TYPICAL)ALUMINUM COLUMNSBY OTHERS (TYPICAL)11-S1081-S10821-S108311-S108SIM.11-S1081-S1082SIM.1-S1082VARIESFROM6" TO 8"EDGE OF SLAB.EDGE OF SLAB.3'-1"3'-1"
T/SLAB
EL. 47'-2"
T/SLAB
EL. 47'-0" T/SLABEL. 47'-0" SLOPE SLOPE
1/4" SLOPE
1/4" SLOPE
1/4" SLOPE
1/4" SLOPE VARIESFROM6" TO 8"6"6"6"6"61-S1081'-0"4"1'-0"4"1'-0"4"1'-0"4"6"1'-0"4"1'-0"4"1'-0"4"1'-0"4"HSS 6.000 X .250BOLLARD (TYP. OF 11)SEE 7/1-S108 FORINFO.123456AB30'-0"
26'-91
2"
24'-912"6"VARIESFROM6" TO 8"VARIESFROM6" TO 8" 1/2" = 1'-0"NPLANNORTHTOP OF SLAB = 0'-0". 0'-0" IS FOR REFERENCE ONLY. SEE CIVIL FOR NVGD ELEVATION.BOTTOM OF FOOTING SHALL BE 18" MIN. BELOW ADJACENT FINISH GRADE. VERIFY ALL TOP OFFOOTING ELEVATIONS W/ ARCHITECTURAL DRAWINGS PRIOR TO FABRICATION ANDCONSTRUCTION.NOTES:2.1. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN. VERIFY ALL DIMENSIONS W/ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION.3.SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ALL SLEEVES, PIPES, INSERTS ANDEMBEDDED ITEMS.4.FOOTING SCHEDULEMARK DIMENSIONSREINFORCINGF606'-0" x 6'-0" X 36"(10) #6 TOP & BOTTOM E.W.SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SLOPES AND RECESSES. SEEPLUMBING DRAWINGS FOR EXACT LOCATIONS.5.7.SEE SHEET 1-S108 FOR TYPICAL WALL REINFORCEMENT DETAIL.JOSE MIGUEL ORTIZ, P.E.
Drawn by:
Designed by:
Approved by:
Checked by:
Scale:
Job No.:
Date:
File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMO
DAS
JMO
JMO www.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)
ORLANDO-SANFORD INTERNATIONAL AIRPORT
SANFORD, FLORIDA
REVISIONS
# DATE DESCRIPTION BY
J:\S12014\Architecture\02_Structural\PHASE I\1-S107.dwg Sep 22, 2017 - 1:38pm daran 1/2" = 1'-0"PARKING CANOPY FOUNDATION PLAN CANOPY FOUNDATION PLAN
1-S107109-22-2017 ADDENDUM NO.555 CONFORMED SET170
T.O. DRIVE THRU SLAB0'-0"10X6 ALUM.COLUMNBY OTHERS.CLREFER TO SCHED.2'-0"CL7"14X22X25" DEEPBLOCKOUT (TYP).6" CONCRETE SLAB,SEE PLAN NOTES FORREINF. INFO. (TYP).CONCRETE FOOTING,SEE PLAN FOR SIZE &REINF.(TYP).6" TO 8"4'-0"1" CHAMFER (TYP).6" -8" HIGH X 4'-0" W ISLANDW/ 6X6, W1.4X1.4 WWF(WHERE APPLIES).NON-SHRINKNON-METALLIC MORTARGROUT MIN. f'c = 5000 psi3"3" CLR.3"6"6"6"8"10X6 ALUM.COLUMNBY OTHERS.CLREFER TO SCHED.2'-0"7"14X22X25" DEEPBLOCKOUT (TYP).CONCRETE FOOTING,SEE PLAN FOR SIZE &REINF.(TYP).FINISH GRADE,SEE CIVIL.1" CHAMFER (TYP).6"-8" HIGH X 4'-0" W ISLANDW/ 6X6, W1.4X1.4 WWF(WHERE APPLIES).NON-SHRINKNON-METALLIC MORTARGROUT MIN. f'c = 5000 psi3"3" CLR.6"6"T.O. DRIVE THRU SLAB0'-0"MONOLITHICSLAB &FOOTING.8"6"2"
8" MIN.6" CONCRETE SLAB W/ 6X6, W1.4XW1.4W.W.F ON 10 MIL. VAPOR BARRIER.SEE ENGINEERING NOTES FOR SOILTESTING AND COMPACTIONREQUIREMENTS.(2)#5 CONT.TOP OF DRIVE THRU SLABREF. ELEVATION = -0'-0"6"6"SIDEWALK, REFERTO CIVIL.1" EXPANSION JOINTMATERIAL.MID-DEPTH
SEE PLAN
d/4SAWCUT MAX. NEXT MORNINGAFTER SLAB IS CAST.FILL W/MASTICW.W.F. ORFIBERMESHOR REBAR.CONTROL JOINTS SHALL BE IN A SQUAREPATTERN OF 400 SQ. FT. AND/OR THE LENGTHSHALL NOT BE MORE THAN 2x WIDTH. ALIGNCONTROL JOINTS W/ COLUMN CENTER LINES.T.O. DRIVE THRU SLAB0'-0"10X6 ALUM.COLUMNBY OTHERS.CLREFER TO SCHED.2'-0"CL7"14X22X25" DEEPBLOCKOUT (TYP).6" CONCRETE SLAB,SEE PLAN NOTES FORREINF. INFO. (TYP).CONCRETE FOOTING,SEE PLAN FOR SIZE &REINF.(TYP).NON-SHRINKNON-METALLIC MORTARGROUT MIN. f'c = 5000 psi3"3" CLR.3"
8"
2"6"1'-9"FINISH GRADE,SEE CIVIL.8'-6"3'-6"HSS 6.000 X 0.250 X 8'-6"HPIPE BOLLARD,FILL W/ CONCRETE (TYP)CONCRETE SLAB,SEE PLAN NOTES FORREINF. INFO. (TYP).6"-8" HIGH X 4'-0" WISLAND W/ 6X6, W1.4X1.4WWF.(WHERE APPLIES). 2'-0" DIA.9"9"4'-0"6"-8"6"3"3'-9"6"JOSE MIGUEL ORTIZ, P.E.
Drawn by:
Designed by:
Approved by:
Checked by:
Scale:
Job No.:
Date:
File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMO
DAS
JMO
JMO www.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)
ORLANDO-SANFORD INTERNATIONAL AIRPORT
SANFORD, FLORIDA
REVISIONS
# DATE DESCRIPTION BY
J:\S12014\Architecture\02_Structural\PHASE I\1-S108.dwg Sep 22, 2017 - 1:14pm daran
CANOPY FOUNDATION DETAILS
1-S108 3/4" = 1'-0"1SECTION3/4" = 1'-0"2SECTION3/4" = 1'-0"3SECTION 3/4" = 1'-0"5SECTION 3/4" = 1'-0"6SECTION 3/4" = 1'-0"4SECTION09-22-2017 ADDENDUM NO.555 CONFORMED SET171
1 1/2" TYP, MINSIDE SEAM WELD DIAGRAM3'-0" MINCONNECTOR PATTERN DIAGRAM(*) REF SIDELAP FASTENERSCHEDULEFOR TYPE OF SIDELAPS,CONNECTOR,AND NUMBER OFCONNECTORS REQUIREDBETWEEN SUPPORTSCL OF JOISTCL OF JOISTCL OF JOIST( ) CONNECTIONS AT 6" OCTO CONT STEEL MEMBER ATALL WALLS, JOISTS, SHEARCOLLECTOR TUBES, ANDAROUND ALL OPENINGS(36/7 PATTERN)*CL OF MASONRY WALLCONNECTIONS TO CONT STEEL MEMBERSAT ALL WALLS, JOISTS, SHEARCOLLECTOR TUBES, AND AROUND ALLOPENINGS (36/7 PATTERN)GRID1'-3"TYP**************************************************************************FASTENER SCHEDULE*( ) DECK TO CONTINUOUS STEEL MEMBER CONNECTOR TYPE WITH ( ) SIDE LAP CONNECTOR SPACING(36/7 PATTERN)POWDER ACTUATED HILTI X-EDNK22-THQ12 HSN WITH (8) #10-16 SELF-DRILLING SCREWS SIDE LAPS AT (9) EQUAL SPACESAIR PNEUTEK K-66056 WITH (7) #10-16 TEKS SIDE LAPS AT (8) EQUAL SPACES#12 SELF DRILLING SCREWS #3 POINT WITH (10) #10-16 TEKS SIDE LAPS AT (11) EQUAL SPACES5/8" DIAMETER PUDDLE WELDS WITH (9) #10-16 TEKS SIDE LAPS AT (10) EQUAL SPACESSUITABLE BASE MATERIALTHICKNESS RANGE, IN.7/64 TO 1/4 INCLUSIVE (POWDER OR AIR)POWDER ACTUATED HILTI X-EDN19-THQ12 HSN WITH (8) #10-16 SELF-DRILLING SCREWS SIDE LAPS AT (9) EQUAL SPACES3/16 TO 3/8 INCLUSIVE (POWDER)3/16 TO 5/16 INCLUSIVE (AIR)ALL THICKNESSES1/8 TO 3/16 INCLUSIVE#12 SELF DRILLING SCREWS #4 POINT WITH (10) #10-16 TEKS SIDE LAPS AT (11) EQUAL SPACES3/16 TO 1/4 INCLUSIVEAIR PNEUTEK SDK-63075 WITH (7) #10-16 TEKS SIDE LAPS AT (8) EQUAL SPACESTHICKER THAN 5/16 (AIR)5/32 TO 1/4 INCLUSIVE (AIR)(7) 24K4 (EQ. SPACES)L1L2L2L1L2L1L1L2L1110'-0"4'-0"8'-0"10'-10"8'-0"9'-0"32-S102 2-S202EQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQ11-S201 1-S202A12BCD1.5 TYPE B GALVANIZED METALDECK BY VULCRAFT1-ROW UPLIFTBRIDGING L1 14X1 14X18BOTTOM CHORD1-ROW UPLIFTBRIDGING L1 14X1 14X18BOTTOM CHORDB/ HP DECK14'-6"B/ LP DECK12'-10-1/2"SLOPE @ 1/2" /FT. (TYP.)SLOPE @ 1/2" /FT. (TYP.)SLOPE @ 1/2" /FT. (TYP.)L2L1L1L2 L2 L2L2CONT. 3 1/2X3 1/2 X1/4"CONT. 3 1/2X3 1/2 X1/4"CONT. 3 1/2X3 1/2 X1/4"CONT. 3 1/2X3 1/2 X1/4"21-S201 1-S20232-S102 2-S20241-S201 1-S20241-S201 1-S20218'-0"36'-8"8"110'-0"2'-0"40'-0"2'-8"8'-0"2'-8"8'-0"4'-0"6'-0"2'-0"3'-4"12'-8"8'-0"2'-8"3'-4"5'-4"3'-4"2'-8"8'-0"3'-4"8'-0"4'-0"8'-0"4'-0"80°3'-4"6'-0"6'-0"3'-4"3'-4"5'-4"11-S201 1-S202L13'-4"1'-4"(4) 24K4 (EQ. SPACES)(8) 24K4 (EQ. SPACES)L1L12-1/2"X2-1/2"X3/16"ANGLE @ 4'-0" O/C1'-4"4'-0"1'-4"4'-0"1'-4"4'-0"1'-4"4'-0"R8F8-1B/1TL1TYPEMARK1011 GRAVITY / 727 UPLIFTALLOWABLE LOADS (lbs./ft.)LINTEL SCHEDULE8RF6-1B/1TL3COMMENTSUP TO 8'-0" DOOR OPENING PRECAST LINTEL,PROVIDE 8" END BEARING EA SIDEUP TO 8'-0" ROUGH OPENING PRECAST LINTEL,PROVIDE 8" END BEARING EA SIDE8F16-1B/1TL2UP TO 12'-0" ROUGH OPENING PRECAST LINTEL,PROVIDE 16" END BEARING EA SIDE112"CLR.GROUTTYPE DESIGNATION:F = FILLED WITH GROUT / U = UNFILLEDNOMINAL WIDTHNOMINAL HEIGHT8" NOMINAL WIDTH8F16-1B/1T#5 REBAR AT BOTTOM OFLINTEL CAVITYBOTTOM REINFORCINGPROVIDED IN LINTEL (VARIES)SEE SCHED'L.7-5/8"#5 REBAR AT TOP MIN. (1)REQ'D.NUMBER OF #5REBAR AT TOPNUMBER OF #5 REBAR ATBOTTOM OF LINTEL CAVITY1254 GRAVITY / 723 UPLIFT755 GRAVITY / 506 UPLIFTJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S201.dwg Jul 12, 2017 - 2:31pm daranS12014LOADING DOCKBUILDINGORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANTERMINALADDITIONWEST1/4" =1'-0" 1/4" = 1'-0"ROOF FRAMING PLANN
NORTHLOADING DOCK BUILDING ROOF FRAMINGPLAN1-S201ROOF CONSTRUCTION:1 1/2" TYPE B X 20 GAGE PHOSPHATIZED AND PAINTED OR GALVANIZED METAL DECK. DECK TO BEATTACHED TO SUPPORTING STEEL BY WELDS OR POWER ACTUATED FASTENERS WITH A PATTERNOF 36/7. SEE DETAIL FOR DECK ATTACHMENT DETAILS ON THIS SHEET. ALSO SEE SPECIFICATIONSOR FINISH SCHEDULE.FINISH METAL DECK AS REQUIRED BY ARCHITECT.STEEL ELEVATIONS GIVEN AS PLUS FEET AND INCHES TO TOP OF STEEL REFERENCED FROMFINISHED FLOOR ELEVATION 0'-0".PROVIDE JOIST BRIDGING IN ACCORDANCE WITH STEEL JOIST INSTITUTE UNLESS NOTEDOTHERWISE.PROVIDE L 2 1/2 x 2 1/2 x 1/4" AT ALL CHANGES IN DECK DIRECTION AND ALL LOCATIONS WHEREDECK IS CUT ON A SKEW.COORDINATE ALL OPENINGS WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. DENOTES DECK SUPPORT ANGLE - CONTINUOUS L 5 x 3 x 5/16 LLV. TYPICAL AT ALLMASONRY WALLS PARALLEL TO STEEL JOISTS UNLESS NOTED OTHERWISE. SEE TYPICAL DETAILS.LX DENOTES PRECAST CONCRETE LINTEL TYPE (SEE SCHEDULE).SEE ARCHITECTURAL DWG'S FOR ACTUAL LOCATION AND SIZE OF DOORAND WINDOW OPENINGS.ROOF FRAMING NOTES:107-14-2017CONFORMED SET172
TYPL 6x6x3/8 x 1'-4" AT 6'-0"OC-ATTACH WITH (2)- 1/2"Ø x0'-5" LONG STUDSEMBEDDED IN BOND BEAML 5x3x5/16" CONTINUOUSWELD TO L 6x6"SEE ARCHITECTURALDRAWINGS FOR WALLCONSTRUCTION- SEE PLANSAND DETAILS FOR WALLREINFORCING REQUIREMENTSL 5x3" CONTIN.CONT. 16" CMU BOND BEAMWITH (2)-#5's CONTIN. HORIZ.L 2x2x1/4" DIAGONALBRIDGING- FIRST JOISTSPACE EXCEPT WHERENOTEDSJI HORIZONTALBRIDGING MINIMUML 3x3L 3x3x1/4" WITH(2)-3/4"Ø ANCHORS INGROUTED MASONRYMETAL DECKHANGINGCONCENTRATEDLOADWHEN NEW CONCENTRATED LOADING CONDITIONS ARE ADDEDTO EXISTING JOISTS, REINFORCE THE JOISTS AT THE LOADAPPLICATION AS SHOWN ABOVE IF THE LOAD IS FURTHER THAN6" FROM THE NEAREST PANEL POINT. NO REINFORCING ISREQUIRED IF THE LOAD IS WITHIN 6" OF THE PANEL POINT.ADD L 2x2x1/8 WEB MEMBER,ONE EACH SIDE OF JOIST ATPOINT OF LOADAPPLICATION- FIELD WELD TOJOIST.CONCENTRATEDLOADJOIST MANUFACTURER TO SHOPREINFORCE AT ALL CONCENTRATEDLOADS WHOSE EXACT LOCATION ISSHOWN ON DRAWINGS - USE THISDETAIL FOR ALL OTHER CASES6" ORGREATER6" ORGREATERTYPICAL JOIST PANELPOINTMC6x8.2 CONTINUOUSUNDER CURBMECHANICAL UNITCURB MAY OCCUR-SEE MECHANICALDRAWINGS. USESTEEL SHIMS ASREQUIRED TOLEVEL CURBSEE ARCHITECTURALDRAWINGS FOR WALLCOMPOSITIONSEE PLANS FORREINFORCINGSLOPEB/ HP DECK14'-81/2"T/PARAPET15'-4"STEEL JOISTREF. PLAN1 1/2" WIDE RIBMETAL DECK - SEEPLAN NOTESL1 14X1 14X18 ADDITONAL ROWOF HORIZ BRIDGING AT FIRSTBOTTOM CHORD PANELPOINT FOR UPLIFT (TYP.)8" CMU WALL3/161-1/2 3/167X7X3/8" EMBEDPLATE W/(2)-5/8"ØX 5" LG. H.S. SEEDETAIL A-AJOIST BEARING14'-4"10X10 MASONRY BONDBEAM W/(1)#5 CONT.CONT. 3 1/2X3 1/2 X1/4" BENT PLATEATTACHED W/ 3/4" DIA.X 4" EMBED STAINLESS STEELEXP. BOLTS @ 32" O.C. INGROUTED CELLSINSULATION ANDBUILT-UP ROOFINGSYSTEM. SEE ARCHDWGS.10" CMU WALLSTEEL JOISTREF. PLAN1 1/2" WIDE RIBMETAL DECK - SEEPLAN NOTESL1 14X1 14X18 ADDITONAL ROWOF HORIZ BRIDGING AT FIRSTBOTTOM CHORD PANELPOINT FOR UPLIFT (TYP.)SEE ARCHITECTURALDRAWINGS FOR WALLCOMPOSITIONSEE PLANS FORREINFORCINGSLOPEB/ LP DECK12'-101/2"T/PARAPET15'-4"8" CMU WALL7X7X3/8" EMBEDPLATE W/(2)-5/8"ØX 5" LG. H.S. SEEDETAIL A-AJOIST BEARING12'-8"CONT. 3 1/2X3 1/2 X1/4"INSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.2"2"EQ.EQ.3"CMU WALL4 #4CONTINUOUS ANGLEANGLE @ 4'-0" O/C2-1/2"X2-1/2"X3/16"2"X2-1/2"X1/4"FILL WITH MORTAR#4 @ 16"WALL PARALLEL TO JOIST11"#3 @ 8"TYP.1/8"TYP.1/8"REF. SCHED.JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATE DESCRIPTION BYJ:\S12014\Architecture\02_Structural\PHASE I\1-S202.dwg Jul 12, 2017 - 2:31pm daranS12014AS SHOWNLOADING DOCK BUILDING ROOF FRAMINGSECTIONS & DETAILS1-S202JOIST REINFORCING DETAIL 'A'NOT TO SCALEDETAIL "A-A" 3/4"=1'-0"TYP. ROOF JOIST BEARING SECTION SCALE: 3/4" =1'-0"11-S202TYP. ROOF JOIST BEARING SECTION SCALE: 3/4" =1'-0"21-S20231-S202AND BRIDGING DETAIL TYP. DECK BEARINGSCALE: 3/4"=1'-0"41-S202TYPICAL WALL ANCHORAGE DETAILS TO JOISTSCALE: 3/4"=1'-0"07-14-2017CONFORMED SET173
8"8'-4" CLEAR8"EXISTING BUILDINGW18X35(EXISTING TO V.I.F.)ELEV.7'-734" CLEAR8"8"4'-1034" (V.I.F)11-S204 1-S204EXISTING STEELCOLUMN (V.I.F.)91-S203 1-S203W12X35W12X35W12X35W12X35W12X35J13812"10'-3" CLEAR8"5'-1"8"8"8'-2" CLEAR8"13'-1034"8"8"± 6'-9" (V.I.F.)W18X35 (EXISTING TO V.I.F.)W8X15W8X15W8X15W8X15W8X15W8X15W8X158"91-S03 1-S03ELEV.SLOPE EXISTINGSTEEL STAIRRELOCATED1.5 TYPE BGALVANIZEDMETALDECK BYVULCRAFTEXISTING BUILDING± 1'-7"(V.I.F.)± 9'-0"(V.I.F.)± 11'-6"(V.I.F.)T/STEEL± 12' 11-1/4"81-S203 1-S-20371-S203 1-S-20341-S203 1-S-203HSS6X6X1/4HSS6X6X1/4HSS6X6X1/42625.825.625.225D11'-0" (V.I.F.)8'-2" CLEAREXISTING BUILDINGW8X15W8X15W8X15W8X15W8X15W8X15W8X15W8X15SLOPE SLOPE SLOPE C12X351.5 TYPE BGALVANIZEDMETAL DECKBY VULCRAFT± 1'-7"(V.I.F.)± 9'-0"(V.I.F.)W14X30 (30'-7 12" EXISTING TO V.I.F.)1.5 TYPE B GALV. MTL.DECK BY VULCRAFT101-S203 1-S20310'-3" CLEAR61-S203 1-S-203HSS6X6X.25 @ 24'-4"HSS6X6X.25 @ 22'-6"± 11'-6"(V.I.F.)41-S203 1-S-20351-S203 1-S-203SLOPE T/STEELLP/28'-6"T/STEELHP/29'-0"T/STEELHP/-71-S203 1-S-203HSS6X6X1/4HSS6X6X1/4T/STEELHP/32'-10 1/2" T/STEELLP/32'-2" 2625.825.625.225DHSS6X6X1/4ELEV. 13'-4"HSS6X6X.25HSS6X6X.25HSS6X6X.25HSS6X6X.25HSS6X6X.25HSS6X6X.25EXISTING W14X30 (V.I.F.)EXISTING W18X35 (V.I.F.)W8X15CEILING ELEV.REF: ARCHMECHANICALDUCT. REF. MECHDOOR ROUGH OPENINGREF. ARCH DRAWINGSSTL. BEAMREF. PLANT/STEELLP/28'-6"T/STEELHP/29'-0"2525.225.625.826T/STL. BEAM21'-1"T/STL. BEAM22'-6"T/STL. BEAM24'-4"ELEV. 13'-4"HSS6X6X.25HSS6X6X.25HSS6X6X.25EXISTING W14X30 (V.I.F.)EXISTINGW18X35C12X35CEILING ELEV.REF: ARCHDOOR ROUGH OPENINGREF. ARCH DRAWINGSSTL. BEAMREF. PLANT/STEELLP/28'-10"T/STEELHP/29'-3-1/2"MECHANICALDUCT. REF. MECH2625.825.621'-1"T/STL. BEAM3'-5"2'-8"STL BEAM.REF. PLAN#3@12"O.C.STIRRUPST/CONC. BEAMLP/32'-2"SLOPET/STEELLP/31'-8"T/CONC. BEAMHP/32'-10 1/2"T/STL. BEAMHP/32'-4 1/2""#3@12"O.C.STIRRUPSELEVATOR HOISTBEAM41-S2031-S204#5@24"O.C.MORTAR FILL CELLS8" CMU WALLB/STEEL BEAM29'-11"INSULATION ANDBUILT-UP ROOFINGSYSTEM. SEE ARCHDWGS.10 #5 CONT.12 #5 CONT.EMBEDPLATE #1EMBEDPLATE #11'-6"1'-6"#3@12"O.C.STIRRUPST/CONC. BEAMLP/32'-2"SLOPET/STEELLP/31'-8"T/CONC. BEAMHP/32'-10 1/2"T/STL. BEAMHP/32'-4 1/2"#3@12"O.C. STIRRUPS8" CMU WALLW/ #5@24"O.C.MORTAR FILL CELLSINSULATION ANDBUILT-UP ROOFINGSYSTEM. SEE ARCHDWGS.STL BEAM.REF. PLAN6 #5 CONT.6 #5 CONT.1'-0" MIN.SPLICEEMBEDPLATE #1W8X15CEILING ELEV.REF: ARCHMECHANICALDUCT. REF. MECHT/STEELLP/28'-6"T/STEELHP/29'-0"ELEV. 13'-4"SLOPEEXISTING STEELSTAIR RELOCATEDALIGN25.625.891-S203 1-S203COMPOSITE CONC. FLOORSLAB. (MATCH TO EXISTING)2ND LEVEL13'-4" EXISTINGTOP OF STL.12'-11 14" EXISTING8" CMU W/ #5 BARS@ 24" O.C.MORTAR FILL CELLSSTL BEAM.REF. PLAN1'-6"1'-0" MIN.SPLICEEMBEDPLATE #1TOP OF STL.LP/28'-6"STL BEAM.REF. PLANSTL BEAM.REF. PLANCLCL111-S2031-S203INSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.T/STL. BEAMLP/28'-6"STL BEAM.REF. PLANSTL BEAM.REF. PLANCLSLOPE T/STL. BEAMHP/29'-0"CLINSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.L3 1/2X3 1/23/16 CONT.LEGENDSHEAR CONNECTIONSJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S203.dwg Jul 12, 2017 - 2:31pm daranELEVATOR SHAFT FRAMING PLAN, SECTIONAND DETAILSS12014AS SHOWN1-S2031/4" = 1'-0"1LOADING DOCK ELEVATOR - 2ND LEVEL FRAMING PLAN1/4" = 1'-0"2LOADING DOCK ELEVATOR - ROOF FRAMING PLAN1/4" = 1'-0"4FRAMING SECTION3/4" = 1'-0"6LOADING DOCK ELEVATOR SHAFT SECTION3ELEVATOR NO.4 - FRAMING PLAN1/4" = 1'-0" @TERMINAL "B"3/4" = 1'-0"8LOADING DOCK ELEVATOR ROOM SECTION1/4" = 1'-0"72ND LEVEL FRAMING SECTION1/4" = 1'-0"5FRAMING SECTION3/4" = 1'-0"9SECTION3/4" = 1'-0"10SECTION3/4" = 1'-0"11SECTION07-14-2017NOTE:FOR ALL STEEL BEAM TO COLUMNSCONNECTIONS REFER TO SHEET 1-S601CONFORMED SET174
(2)∠4"x4"x38"x7.5"-A363"(4)34"Ø HIT-RE500-SD+HASEMBEDDED 6"W8X48-A992End Offset = 0.5in.112"(2) BOLTS 34"ØA325-N-STD Ga.=2.5 in.138"112"3"112"W8X48538"112"8" CMU W/ #5 BARS@ 24" O.C.MORTAR FILL CELLST/CONC. BEAM29'-6"TOP OF STL.29'-2 1/2"B/HOISTWAY BEAM26'-2"3'-6"T/CMU WALL25'-11 1/2"1'-278"ELEV.=30'-7 1/2"SLOPE T/STL BEAMINSULATION AND BUILT-UPROOFING SYSTEM. SEE ARCH DWGS.EXISTING MTL. DECKAND "Z" PURLINS (V.I.F.)#3@12"O.C.STIRRUPS2#6 (TOP)(10) #4 CONT 2#6 (BOT)EXISTING STL.COLUMN (V.I.F.)EXISTING STL.BEAM (V.I.F.)41-S2041-S204JSTL. BEAMRE: PLAN & SCHEDEMBEDPLATE #1EMBEDPLATE #12'-10"2'-6" MIN. SPLICE8" CMU W/ #5 BARS@ 24" O.C.MORTAR FILL CELLS2#6 (TOP)(8) #4 CONT 2#6 (BOT)2#6 (TOP)(8) #4 CONT 2#6 (BOT)COMPOSITE CONC.FLOOR SLAB. (MATCHTO EXISTING)2ND LEVEL13'-4" EXISTINGTOP OF STL.12'-11 14" EXISTING#3@12"O.C.STIRRUPS13'-4"T/CONC. BEAMEXISTING STL.COLUMN (V.I.F.)EXISTING STL.BEAM (V.I.F.)21-S2041-S204STL. BEAMRE: PLAN & SCHEDEMBEDPLATE #111'-10"CENTER OF STL. PLATEEMBEDPLATE #2TOP OF STL.12'-11 14"NOTE: FOR SIGNAGE STRUCTURAL FRAMING AND STEELCONNECTIONS REFER TO SHEET 1-S205&1-206132ND LEVELEXISTINGSTL. BEAMRE: PLAN & SCHEDL- CONT.EXISTING STEELCOLUMN (V.I.F)TOP OF STL.12'-11 14" EXISTINGEXISTING STL.BEAM (V.I.F)31-S2041-S204COMPOSITE CONC.FLOOR SLAB.CLCLCLJSTL. BEAMRE: PLAN & SCHED2ND LEVEL13'-4" EXISTINGTOP OF STL.12'-11 14" EXISTINGEXISTING STEELCOLUMN (V.I.F)12"4"1'-0"2"4"4"2"10"2"6"2"EMBED PLATE #11. NOTES:ALL STUDS ARE 34" DIA. X 4" LENGTH PERTHE NELSON STUD COMPANY.2. ALL EMBED PLATES ARE 12" THICK, (U.N.O.).12"4"1'-4"2"4"4"2"10"2"6"2"EMBED PLATE #21. NOTES:ALL STUDS ARE 34" DIA. X 4" LENGTH PERTHE NELSON STUD COMPANY.2. ALL EMBED PLATES ARE 12" THICK, (U.N.O.).4"1 1/2" = 1'-0"4SECTIONJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S204.dwg Jul 12, 2017 - 2:31pm daranELEVATOR SHAFT FRAMING SECTIONS ANDDETAILS1-S2041ELEVATOR NO.4 STRUCTURAL PARTIAL SECTION3/4" = 1'-0" @TERMINAL "B"3/4" = 1'-0"2SECTION3/4" = 1'-0"3SECTION07-14-2017AS SHOWNS12014NOTE:FOR ALL STEEL BEAM TO COLUMNSCONNECTIONS REFER TO SHEET 1-S601CONFORMED SET175
ELEV.131211JJ.330'-0" (V.I.F.)30'-0" (V.I.F.)12'-5" (V.I.F.)K27'-2" (V.I.F.)W18X35 (EXISTING TO V.I.F.)W24X76 (EXISTING TO V.I.F.)W18X35 (EXISTING TO V.I.F.)W24X76(EXISTINGTO V.I.F.)W18X35 (EXISTING TO V.I.F.)W24X55 (EXISTING TO V.I.F.)W18X35 (EXISTING TO V.I.F.)W18X35 (EXISTING TO V.I.F.)T/STEEL (EXISTING)± 12' 11-1/4"ELEV.12.419'-4" (V.I.F.)10'-8" (V.I.F.)39'-7" (V.I.F.)21-S205W12X35W12X35W12X35W12X35W12X35T/STEEL 12' 11-1/4"8'-7"11.713.39'-1"8'-11"24'-0"11'-4"9'-10"3'-4"3'-5"3'-212"3'-312"R24'-0"(AT CENTER OF ARC FRAME)24'-0"CIRCULAR SIGN STL. FRAMECIRCULAR SIGN STL. FRAME10.86'-4" (V.I.F.)51-S20531-S20531-S20641-S206SPLICE LOCATIONSPLICE LOCATION61-S2051-S20571-S2051-S20571-S2051-S20513121112.411.713.3T/STEEL FRAMING12' 11-1/4"F.F.ELEV.0'-0"2'-3"10'-834"10.8W14X74 (EXISTING TO V.I.F.)W14X74 (EXISTING TO V.I.F.)HSS6X6X1/2 (EXISTING TO V.I.F.)W14X74 (EXISTING TO V.I.F.)W14X74 (EXISTING TO V.I.F.)W24X55 (EXISTING TO V.I.F.)13.3ELEV.812"ENTRY SIGN STL. FRAMINGT/STL. FRAME12' 11-1/4"BENT PLATE 8X6X3/16X1-0"LONG WELDED TO EMBED PLATE11-S2051-S204ELEVATOR SHAFTCONCRETE TIE BEAM61-S2051-S20511.741-S2051-S205J.3ENTRY SIGN STL. FRAMINGT/STL. FRAME12' 11-1/4"(2) BENT PLATE 8X6X3/16X1-0"LONG WELDED TO EXISITNGSTEEL BEAMEXISTING W24X55 STEELBEAM (V.I.F.)38" STIFFNER PLATES61-S2051-S205J.3TOP OF STL.12'-11 14"SIGN STL. FRAMING(2) BENT PLATE 8X6X3/16X1-0"LONG WELDED TO EXISTING BEAMEXISTING W18X35STEEL BEAM (V.I.F.)712"1'-0"EXISTING W24X55 STEELBEAM (V.I.F.)5"2'-3"ALIGNHSS3X3X1/4HSS3X3X1/4HSS3X3X1/4HSS3X3X1/4HSS
3
X
3
X
1/
4
HSS
3
X
3
X
1/
4(2) 38" STIFFNERPLATES61-S2051-S205A1-S206B1-S206B1-S20613.3TOP OF STL.12'-11 14"2'-3"11.7HSS3X3X1/4BOT. OF STL.10'-8 3/4"HSS3x3X1/4HSS3x3X1/4HSS3x3X1/4 PL 3X6X12" PL 3X6X12"HSS3x3X1/4HSS3x3X1/4HSS3x3X1/4HSS
3
x
3
X
1/
4 HSS3x3X1/413.3TOP OF STL.12'-11 14"2'-3"11.7HSS3X3X1/4BOT. OF STL.10'-8 3/4" PL 3X6X12" PL 3X6X12"81-S205 PL 3X6X12"JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S205.dwg Jul 12, 2017 - 2:31pm daranCIRCULAR ENTRY SIGN -TYPE "I" FRAMINGPLAN AND STEEL CONNECTION DETAILSS12014AS SHOWN1-S2051/4" = 1'-0"1CIRCULAR ENTRY SIGN -TYPE "I" FRAMING PLAN07-14-20171/4" = 1'-0"2CIRCULAR ENTRY SIGN -TYPE "I" FRAMING PLAN3/4" = 1'-0" PLAN VIEW3FRAMING CONNECTION 13/4" = 1'-0"4SECTION3/4" = 1'-0"5SECTION3/4" = 1'-0"6SECTION3/4" = 1'-0"7SECTION3/4" = 1'-0"8SECTIONN.T.S. PERSPECTIVE VIEWSPLICE CONN. DETAILNOTE:FOR ADDITIONAL SIGNAGE INFORMATION REFER TOWAYFINDING DRAWING SET ON SHEET W204NOTE:FOR ALL STEEL BEAM TO COLUMNSCONNECTIONS REFER TO SHEET 1-S601CONFORMED SET176
12HSS3X3X1/4HSS3X3X1/4HSS3X3X1/4TOP OF STL.12'-11 14"2'-3"EXISTING W14X74 STL.COLUMN (V.I.F.)KC1-S206KHSS3X3X1/4HSS3X3X1/4HSS3X3X1/4EXISTING W14X74 STL.COLUMN (V.I.F.)12'-11 14"TOP OF STL.2'-3"38" STIFFNER PLATES13HSS3X3X1/4C1-S206O.H.12K12' 11-1/4"EXISTING W14X74 STL.COLUMN (V.I.F.)HSS3X3X1/4HSS3X3X1/4HSS3X3X1/43'-212"3'-3"61-S20651-S20638" STIFFNER PLATES(2) PLATE 3X2-1/2X1/4X1-9"LONG WELDED TO EXISTINGSTL. COLUMN(2) PLATE 3X2-1/2X1/4X1-9"LONG WELDED TO EXISTINGSTL. COLUMNT/STL. FRAME71-S2061-S205HSS3X3X1/4HSS3X3X1/4HSS
3
X
3
X
1/
4HSS3X3X1/4HSS3X3X1/4HSS3X3X1/4HSS3X3X1/4HSS3X3X1/4(2) BENT PLATE8X6X3/16X1-0"LONG WELDED TOEMBED PLATE13K12' 11-1/4"HSS3X3X1/4HSS3X3X1/4HSS3X3X1/451-S20661-S2063'-5"3'-4"EXISTING W14X74 STL.COLUMN (V.I.F.)38" STIFFNER PLATES(2) PLATE 3X2-1/2X1/4X1-9"LONG WELDED TO EXISTINGSTL. COLUMN(2) PLATE 3X2-1/2X1/4X1-9"LONG WELDED TO EXISTINGSTL. COLUMNT/STL. FRAME71-S2051-S2061'-6"11.713.348'-0"13123'-0"3'-0"3'-9"3'-2"3'-2"
3'-2"
3'-2"
3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-9"3'-0"3'-0"3'-0"R24'-0"(AT CENTER OF ARC FRAME)SPLICE LOCATIONSPLICE LOCATIONK3'-0"3'-0"3'-8"3'-2"3'-2"
3'-2"
3'-2"
3'-2"
3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-2"3'-8"3'-0"3'-0"1'-6"11.713.348'-0"1312CLR24'-0"(AT CENTER OF ARC FRAME)SPLICE LOCATIONSPLICE LOCATIONK1/4"HSS3x3X1/4HSS3x3X1/4HSS3x3X1/4FULL WELDEDGRIND TO FINISHHSS3x3X1/4HSS3x3X1/4FULL WELDEDGRIND TO FINISH1/4"HSS3X3X1/4(2) PLATE3X2-1/2X1/4X1-9"LONG WELDED TOEXISTINGSTL. COLUMNGRIDFACE OFEXISTINGSTL. COLUMNHSS3x3X1/4HSS3x3X1/4HSS3x3X1/4 FULL WELDEDGRIND TO FINISH1/4"HSS3x3X1/4HSS3x3X1/41/4"FULL WELDEDGRIND TO FINISHJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S206.dwg Jul 12, 2017 - 4:10pm daranCIRCULAR ENTRY SIGN -TYPE "I" FRAMINGSECTIONS AND DETAILSS12014AS SHOWN1-S20607-14-20171/4" = 1'-0"1TOP CHORD TRUSS CENTER LOCATIONS1/4" = 1'-0"2BOTTOM CHORD TRUSS CENTER LOCATIONS3/4" = 1'-0" PLAN VIEW3FRAMING CONNECTION 23/4" = 1'-0" PLAN VIEW4FRAMING CONNECTION 23/4" = 1'-0"5SECTION3/4" = 1'-0"6SECTIONN.T.S.PERSPECTIVE VIEWS1" = 1'-0"ATYP. DETAIL1" = 1'-0"BTYP. DETAIL1" = 1'-0" PLAN VIEWTYP. COLUMN CONN1" = 1'-0"DTYP. DETAIL1" = 1'-0"CTYP. DETAILNOTE:FOR ADDITIONAL SIGNAGE INFORMATION REFER TOWAYFINDING DRAWING SET ON SHEET W204NOTE:FOR ALL STEEL BEAM TO COLUMNSCONNECTIONS REFER TO SHEET 1-S601CONFORMED SET177
34'-10"25'-2" (V.I.F.)EXISTING 48"Ø STORM PIPE TO BE PROTECTEDFACE OF WALL
EXISTING
EXISTING BUILDINGEXISTING BUILDING
SC1F105.65.763'-2"SC2F8626'-3"
19'-7"5'-0"
12'-9"SC2F8SC2F838'-0" (V.I.F.)5.526'-3"34'-10"19'-7"F.1G.7H.7SC1F10SC2F8H.35'-0"11-S3021-S401G.8G.5G.97CF4.8CF4.8CF4.8#3@12" O.C.E.W.T=6"NOTE: G/C TO REMAIN EXISTING CONCRETE SLAB SLOPE 1-1/2" NON-SHRINK GROUTCOAT COLUMN BELOW SLABW/ BITUMASTIC PRESERVATIVE TYPBASE PLATE BP1#3@4"CONCRETEPILASTER W/ #3 TIE(8) #5 VERTW/ STD ACI 90° HOOKVAPOR BARRIERREF. FOOTING SCHED.REFER TO SCHEDULEREFER SCHED.2'-4" MIN.
1'-4"1-1/2"REBAR REINFREF. TO PLANREF. FOOTING SCHED.1'-9"STL. PL.18"x18"x t1'-3"REF. SCHEDULE4-A307 3/4"Ø X 18"BOLTS 12" EMBEDMENTCOLUMN PEDESTAL21"x21"BASE PLATE BP1112"1'-6"1'-9"AA112"BASE PLATE BP1PEDESTAL FOR1'-9"1'-9"(8) #5#3@4"EXISTING BUILDINGEXISTING BUILDING 112222222± 36'-3" (V.I.F.)± 76'-9" (V.I.F.)± 82'-10" (V.I.F)EXISTING 48"Ø STORM PIPE TO BE PROTECTEDJOSE MIGUEL ORTIZ, P.E.
Drawn by:
Designed by:
Approved by:
Checked by:
Scale:
Job No.:
Date:
File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMO
DAS
JMO
JMO www.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)
ORLANDO-SANFORD INTERNATIONAL AIRPORT
SANFORD, FLORIDA
REVISIONS
# DATE DESCRIPTION BY
J:\S12014\Architecture\02_Structural\PHASE I\1-S301.dwg Sep 22, 2017 - 1:17pm daran 1/8" = 1'-0"CONCRETE SLAB DEMOLITION PLANNNORTH 1/8" = 1'-0"FOUNDATION FLOOR PLANNNORTHTERMINALADDITIONWESTNEW BLDGEXPANSIONORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLANTOP OF SLAB = 0'-0". 0'-0" IS FOR REFERENCE ONLY. SEE CIVIL FOR NVGD ELEVATION.TOP OF FOOTINGS @ EL. (-2'-4") MIN. BELOW TOP OF SLAB UNLESS NOTED OTHERWISE.BOTTOM OF FOOTING SHALL BE 18" MIN. BELOW ADJACENT FINISH GRADE. VERIFY ALLTOP OF FOOTING ELEVATIONS W/ ARCHITECTURAL DRAWINGS PRIOR TO FABRICATIONAND CONSTRUCTION.NOTES:2.1. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN. VERIFY ALLDIMENSIONS W/ ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION.3.SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ALL SLEEVES, PIPES, INSERTS ANDEMBEDDED ITEMS.4.SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SLOPES AND RECESSES. SEEPLUMBING DRAWINGS FOR EXACT LOCATIONS.5.F88'-0" X 8'-0"X16"FOOTING SCHEDULEMARK DIMENSIONSREINFORCINGF1010'-0" X 10'-0" X 24"(12) #6 E.W. TOP & BOTTOM"t""N""B"BASE PLATEMARKSHAPESTEEL COLUMN SCHEDULEANCHOR BOLTS"L"SIZEQUANTITYSC118" 18" 1-1/8"(4)3/4"W12X7912"(7) #6 E.W. TOP & BOTTOMSC218" 18 1-1/8"(4)3/4"W12X6512"TYPICAL COLUMN ON SPREAD FOOTINGA1-S3011-S301SCREENING BLDG. EXPANSION-
DEMOLITION AND FOUNDATION PLANSTEEL COLUMN BASE PLATE1-S30112DEMOLITION LEGENDEXISTING CONCRETESLAB TO BE REMOVED.NEW SCREENING ROOMEXPANSION FOOTING.12CF4.84'-0" X 8'-0" X 16"(4) #6 E.W. TOP & BOT. & (8) #6 E.W. TOP & BOT.07-14-2017
AS SHOWN
S12014
09-22-2017 ADDENDUM NO.5 55 CONFORMED SET178
20LH0820LH0820LH0832G6N28.4K26'-3"34'-10"19'-7"FACE OF WALLEXISTINGMECH CHASE OPEN SPACEF.1G.7H.3H.765.65.763'-2"25'-2" (V.I.F.)(4) EQ. SPACES(7) EQ. SPACES(6) EQ. SPACES5'-0"38'-0" (V.I.F.)40G7N28.4K24G4N28.4K32G6N28.4KW12X1940G7N28.4K24G4N28.4K61-S302 1-S30351-S302 1-S30341-S302 1-S3035.520LH0820LH0820LH08(4) EQ. SPACES(7) EQ. SPACES(6) EQ. SPACES31-S302 1-S30311-S302 1-S303771-S302 1-S30321-S302 1-S40121-S302 1-S303EXISTING BUILDINGEXISTING BUILDINGW36X150 (EXSTING TO V.I.F.)W36X150 (EXSTING TO V.I.F.)W36X150 (EXSTING TO V.I.F.)T/CONC.SLABELEV=13'-4"1.5 VL1 BY VULCRAFT METAL DECK(SEE TABLE ON SH. 1-S201 FORDECK INSTALLATION)18LH02 @ 6'-0" MAX SPACING6'-3"6'-3"66'-0" (11@6'-0")FACE OF WALLEXISTINGEXISTING BUILDINGEXISTING BUILDING51-S302 1-S30421-S302 1-S40163'-2"25'-2" (V.I.F.)26'-3"34'-10"19'-7"38'-0" (V.I.F.)W18X35W12X 19W18X35W18X35W18X35W12X19W18X35W18X3520LH03 @ 6'-0" MAX SPACING41-S302 1-S30431-S302 1-S304F.1G.7H.3H.765.65.75.5711-S302 1-S304W14X30 (EXSTING TO V.I.F.)W14X30 (EXSTING TO V.I.F.)W14X30 (EXSTING TO V.I.F.)W21X44 (EXSTING TO V.I.F.)W21X44 (EXSTING TO V.I.F.)W21X44 (EXSTING TO V.I.F.)21-S302 1-S30461-S302 1-S30461-S302 1-S304(3) MC12X35SLOPESLOPE1'-0"81-S302 1-S30491-S302 1-S3041.5 VL1 BY VULCRAFT METALDECK (SEE TABLE ON SH. 1-S201FOR DECK INSTALLATION)1.5 VL1 BY VULCRAFT METAL DECK(SEE TABLE ON SH. 1-S201 FORDECK INSTALLATION)JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S302.dwg Jul 12, 2017 - 2:31pm daranSCREENING BLDG. EXPANSION-2ND LEVEL AND ROOF FRAMING PLANTERMINALADDITIONWESTNEW BLDGEXPANSIONORLANDO SANFORD INTERNATIONAL AIRPORTKEY PLAN1-S302 1/8" = 1'-0"SECOND LEVEL FRAMING PLANNNORTH 1/8" = 1'-0"ROOF FRAMING PLANNNORTH1207-14-2017AS SHOWNS12014CONFORMED SET179
F.1EXISTING STL. COLUMNREF. PLAN AND SCHED.CLSTABILIZER PL- 1/2"x6"x0'-6"(MIN) W/ 13/16 DIA HOLE FORCONNECTION OF TEMPORARYBRACING GUYING CABLES TYPDO NOT WELD BOTTOMCHORD TO STABILIZERPLATE TYPL4 34 X 4 X 1/4 CONT.4 3/4" COMPOSITECONC. FLOOR SLAB - TYP.STL. JOISTREF. SCHED.STL. JOIST GIRDERREF. SCHED.2ND LEVEL13'-4" (EXISTING)L4 34 X 4 X 1/4 CONT.STL. JOISTREF. PLAN2ND LEVEL13'-4" (EXISTING)4 3/4" COMPOSITECONC. FLOOR SLAB - TYP.7L 12"X12" 58" BENT PLATE X 8"LONG W/ 14" STIFFH.7STL. COLUMNREF. PLAN AND SCHED.CLSTABILIZER PL- 1/2"x6"x0'-6"(MIN) W/ 13/16 DIA HOLE FORCONNECTION OF TEMPORARYBRACING GUYING CABLES TYPDO NOT WELD BOTTOMCHORD TO STABILIZERPLATE TYPL4 34 X 4 X 1/4 CONT.4 3/4" COMPOSITECONC. FLOOR SLAB - TYP.STL. JOISTREF.PLANSTL. JOIST GIRDERREF. SCHED.2ND LEVEL13'-4" (EXISTING)STL. BEAMRE: PLAN±4'-6"(CANTILEVER TO EXISTING MTL. WALL PANEL)FACE OF EXISTINGMETAL BLDG. WALLPANEL(V.I.F)G.7STL. COLUMNREF. PLAN AND SCHED.CLSTABILIZER PL- 1/2"x6"x0'-6"(MIN) W/ 13/16 DIA HOLE FORCONNECTION OF TEMPORARYBRACING GUYING CABLES TYPDO NOT WELD BOTTOMCHORD TO STABILIZERPLATE TYPL4 34 X 4 X 1/4 CONT.4 3/4" COMPOSITECONC. FLOOR SLAB - TYP.STL. JOISTREF. PLANSTL. JOIST GIRDERREF. PLAN2ND LEVEL13'-4" (EXISTING)H.3STL. COLUMNBEYOND611/811/8JOIST GIRDER BOTTOM CHORD BRACESAS REQUIRED BY SJI SPECIFICATIONSAND JOIST GIRDER DESIGN (UPLIFT) TOBE SUPPLIED BY JOIST SUPPLIER. DO NOTWELD BRACES UNTIL ALL ROOF DEADLOADS ARE APPLIEDBY JOISTSUPPLIER TYP(2) 1/2" DIA ERECTIONBOLTS AT EACH JOIST TYPHSS3 1/2x2 1/2x1/4 BETWEENJOIST IN FIRST (2) BAYSFROM PERIMETER. HSSOFFSET FROM GRID LINE RE:PLAN FOR LOCATION3/16 33/16 3JOIST TOJOIST GIRDERWELD3/16 3-10HSS TO JOISTTOP CHORDWELD2ND LEVEL13'-4" (EXISTING)STL. COLUMNBEYOND5.711/811/8JOIST GIRDER BOTTOM CHORD BRACESAS REQUIRED BY SJI SPECIFICATIONSAND JOIST GIRDER DESIGN (UPLIFT) TOBE SUPPLIED BY JOIST SUPPLIER. DO NOTWELD BRACES UNTIL ALL ROOF DEADLOADS ARE APPLIEDBY JOISTSUPPLIER TYPADDITONAL ROW OF HORIZBRIDGING AT FIRSTBOTTOM CHORD PANELPOINT FOR UPLIFT TYP2ND LEVEL13'-4" (EXISTING)L4 34 X 4 X 1/4 CONT.4 3/4" COMPOSITECONC. FLOOR SLAB - TYP.STL. JOIST GIRDERREF. SCHED.STL. JOISTREF. SCHED.EXISTINGSTL. COLUMNSTL. JOIST GIRDERREF. PLAN AND SCHED.STABILIZER PL- 1/2"x6"x0'-6"(MIN) W/ 13/16 DIA HOLE FORCONNECTION OF TEMPORARYBRACING GUYING CABLES TYPCOLEXISTINGSTL. BEAM2ND LEVEL13'-4" (EXISTING)JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S303.dwg Jul 12, 2017 - 2:31pm daranSCREENING BLDG. EXPANSION- 2ND LEVELFRAMING SECTIONS AND DETAILS1-S303SECTION1 3/4" = 1'-0"SECTION2 3/4" = 1'-0"SECTION4 3/4" = 1'-0"SECTION5 3/4" = 1'-0"SECTION6 3/4" = 1'-0"SECTION7 3/4" = 1'-0"SECTION3 3/4" = 1'-0"07-14-2017AS SHOWNS12014NOTE:FOR ALL STEEL BEAM TO COLUMNSCONNECTIONS REFER TO SHEET 1-S601CONFORMED SET180
T/STEEL28'-8-1/2" (EXISTING)CLSLOPEINSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.MATCH TO EXISTINGSTL. BEAMRE: PLAN & SCHEDEXISTING STL. COLUMNREF. PLAN AND SCHED.STL. JOISTREF. SCHED.INSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.MATCH TO EXISTINGT/STEEL(EXISTING)L 12"X12" 58" BENT PLATE X 8"LONG W/ 14" STIFF. TYP.SLOPEINSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.STL. BEAMRE: PLAN & SCHEDSTL. BEAMRE: PLAN & SCHEDCLG.7STL. JOISTREF. SCHED.STL. COLUMNREF. PLAN AND SCHED.CLH.3STL. JOISTREF. SCHED.INSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.STL. BEAMRE: PLAN & SCHEDSTL. COLUMNREF. PLAN AND SCHED.6STL. JOISTREF. SCHED.INSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.STL. BEAMRE: PLAN & SCHEDSTL. COLUMNREF. PLAN AND SCHED.5.7T/STEELVARIESSTL. JOISTREF. SCHED.INSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.STL. BEAMRE: PLAN & SCHEDSTL. COLUMNREF. PLAN AND SCHED.5.7SLOPESHIM ASREQUIREDC-CHANNELREF. PLAN6"-18GA. METAL STUDSAT 16" O.C. MAX., TYP.6SLOPEC-CHANNELREF. PLANSTL. BEAMREF. PLAN.SHIM ASREQUIRED6"-18GA. METAL STUDSAT 16" O.C. MAX., TYP.STL. JOIST REF. SCHED.STL. JOIST REF. SCHED.7102-S3072-S307STL. CHANNELREF. PLANEXISTINGSTEEL COLUMNB/DECKV.I.F.L3 1/2X3 1/2X3/16 CONT.EXISTING BEAM(W21X44)(V.I.F.)SLOPEMATCH EXISTINGROOF ELEVATIONL 12"X12" 58" BENT PLATE X8" LONG W/ 14" STIFF. TYP.STL. STUB COLUMNRE: PLAN6"-18GA. METAL STUDSAT 16" O.C. MAX., TYP.H.7SLOPEINSULATION AND BUILT-UPROOFING SYSTEM. SEEARCH DWGS.STL. BEAMRE: PLAN & SCHEDCLSTL. JOISTREF. SCHED.STL. COLUMNREF. PLAN AND SCHED.T/STEEL72-S3072-S307±4'-6"(CANTILEVER TO EXISTING MTL. WALL PANEL)(V.I.F)STL. BEAMRE: PLAN & SCHEDVARIESSEE ARCH.H.7SLOPESTL. STUB COLUMNRE: PLANEXISTING W21X44 (V.I.F.)T/STEEL BEAMMATCH EXISTING ROOF ELEVATIONSTEEL JOIST REF. PLANSTL. CHANNELREF. PLANL 12"X12" 58" BENT PLATEX 8" LONG W/ 14" STIFF. TYP.6"-18GA. METAL STUDSAT 16" O.C. MAX., TYP.L3 1/2X3 1/2X3/16CONT.L3 1/2X3 1/2X3/16 CONT.1.5 VL1 BY VULCRAFTMETAL DECKCLSTL. PL. .25"E70 XX1/4"1/4"E70 XX1/4"1/4"E70 XX1/4"1/4"STL. PL. .25"FRONT VIEWSIDE VIEWPERSPECTIVE VIEWL 12"X12" 58" BENTPLATE X 8" LONGW/ 14" STIFFL 12"X12" 58" BENTPLATE X 8" LONGW/ 14" STIFFSECTION1 3/4" = 1'-0"SECTION2 3/4" = 1'-0"SECTION3 3/4" = 1'-0"JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S304.dwg Jul 12, 2017 - 2:31pm daranSCREENING BLDG. EXPANSION- ROOF LEVELFRAMING SECTIONS AND DETAILS1-S304SECTION4 3/4" = 1'-0"SECTION5 3/4" = 1'-0"SECTION6 3/4" = 1'-0"SECTION7 3/4" = 1'-0"SECTION8 3/4" = 1'-0"SECTION9 3/4" = 1'-0"SECTION10 3/4" = 1'-0"07-14-2017AS SHOWNS12014NOTE:FOR ALL STEEL BEAM TO COLUMNSCONNECTIONS REFER TO SHEET 1-S601CONFORMED SET181
0'-0"6'-8" (13 RISERS @7")6'-8" AFFLANDING13'-4" A.F.FF.F.ELEV.6'-8" (11 EQ.RISERS )HSS 4x4x14"HSS 4x4x14"51-S401 1-S401111-S401 1-S40141-S401 1-S40191-S401 1-S40181-S401 1-S4012ND. LEVELG.5G.8G.9G.7REFER TO SCHED.REFERTO SCHED.REFER TO SCHED.REFERTO SCHED.REFER TO SCHED.REFERTO SCHED.5'-11" (LANDING)9'-2" (10 TREADS @11")9'-2" (10 TREADS @11")BENDED CHK'DST PL 316" TYP.111-S401 1-S4019'-1"31-S401 1-S4018'-1"5'-7"4'-11"4'-8"3'-4"1'-2"DN4'-11"6"6"14'-7"DN5'-7"4"5.55.65.7G.5G.8G.9G.7101-S4015.55.65.7G.5G.8G.9G.771-S401 1-S40171-S401 1-S40131-S401 1-S4018'-1"5'-7"4'-11"4'-8"1'-2"BENDED CHK'DST PL 316" TYP.MC12x31111-S401 1-S401UP6"6"14'-7"5'-7"4"∠3x3x38"x0'-9"W/ (2) 78"ØHIT-HAS-E+RE500(EMBEDED 5")1/4" WELDED CLOSUREPLATE ON ENDGRIND SMOOTHMC12x314"11"4"7"1"∠112"x112"x316"x0'-9"∠112"x112"x316"x0'-4"316"0'-0"F.F. ELEV.BENDED CHK'D STPL 316" TYP.7"11"4"BENDED CHK'D STPL 316" TYP.MC12x31∠112"x112"x316"x0'-9"∠112"x112"x316"x0'-4"MC12x313"LANDING ELEV.1"111-S4011-S401∠312"x312"x316"1.5C24 W/4x4-W4.0 x W4.06'-8"MC12x317"11"4"BENDED CHK'DST PL 316" TYP.8"1"6'-8"LANDING-MC12x31HSS 4x4x14"61-S401 1-S4011.5C24 W/4x4-W4.0 x W4.0∠312"x312"x316"G.5MC12x31BENDED CHK'DST PL 316" TYP.G.813'-4"2ND LEVELHSS 4x4x14"MC12x31BENDED CHK'D STPL 316" TYP.∠112"x112"x316"6'-8"LANDING ELEV.PL 6x4x316"-A36(2) BOLTS 58"ØA325-N-STD112"3"112"112"HSS 4x4x14"78"18"18"112"3"112"112"78"W12x16 - A992End Offset=0.375 in.MC12x314"∠312"x312"x316"1.5C24 W/4x4-W4.0 x W4.05.55.610"10"112"7"112"112"7"112"(4) 34"Ø A307BOLTSEMBEDDED 9"HSS 4x4x14"14"PL 10x10x118"G.55.55.6G.8G.9MC12x316'-8"LANDING ELEV.HSS 4x4x14"1'-0"G.5STRUCTURAL STAIRS ENLARGED PLAN,SECTIONS AND DETAILSJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S401.dwg Jul 12, 2017 - 2:31pm daran 1/2" = 1'-0"STAIR STRUCTURAL SECTIONS12014 1/2" = 1'-0"21-S401 1-S40131-S401 1-S401 1/2" = 1'-0"EXTERIOR STAIR STRUCTURAL PLAN @ GROUND LEVEL11-S401 1-S401EXTERIOR STAIR STRUCTURAL PLAN @ SECOND LEVELSTAIR DETAIL1-1/2" = 1'-0"41-S401 1-S401STAIR DETAIL1-1/2" = 1'-0"81-S401 1-S401STAIR DETAIL91-S401 1-S401STAIR DETAIL1-1/2" = 1'-0"51-S401 1-S401SECTION1-1/2" = 1'-0"111-S401 1-S401SECTION1-1/2" = 1'-0"61-S401 1-S401STEEL PLATE1-1/2" = 1'-0"71-S401 1-S401SECTION1-1/2" = 1'-0"101-S401 1-S4011-1/2" = 1'-0"AS SHOWN1-S40107-14-2017NOTE:FOR ALL STEEL BEAM TO COLUMNSCONNECTIONS REFER TO SHEET 1-S601CONFORMED SET182
EXISTINGSTEEL STAIRTO BE REMOVEDEXISTINGSTEEL STAIRTO BE REMOVEDEXISTINGSTEEL STAIRTO BE REMOVEDEXISTINGLIFT TO BEREMOVEDEXISTINGWALLS TO BEREMOVED41-S501 1-S50151-S501 1-S50151-S501 1-S50131-S501 1-S5012423DCEXISTING BUILDINGEXISTING BUILDINGELEV.21-S501 1-S5011ELEV.=+4'-0"F.F.ELEV.ELEV.=(-5'-0" EXISTING)ELEVATOR PITELEV.=0'-0"F.F.ELEV.1ELEV.=+4'-0"F.F.ELEV.T/FOOTINGF.F.ELEV.EXISTING WALLTO BE REMOVEDEXISTING THICKNESSSLAB TO BE REMOVEDELEV.=+4'-0"F.F.ELEV.ELEV.=0'-0"F.F.ELEV.ELEV.=(-5'-0" EXISTING)ELEVATOR PIT1ELEV.=+4'-0"F.F.ELEV.T/FOOTINGF.F.ELEV.JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S501.dwg Jul 12, 2017 - 2:32pm daranEXISTING LOADING DOCK SLABDEMOLITION PLANS12014AS SHOWN1-S5011/4" = 1'-0"1EXISTING LOADING DOCK SLAB DEMOLITION PLANSLAB DEMOLITION LEGENDEXISTING 48" RAISED CONCRETE PLATFORM, CONCRETE WALL, THICKNESSSLAB AND FOOTING AREA TO BE REMOVED.1SECTION3 3/4" = 1'-0"SECTION4 3/4" = 1'-0"SECTION2 3/4" = 1'-0"SECTION5 3/4" = 1'-0"EXISTING CONCRETE SLAB AND FOOTING TO REMAIN21111111222222DENOTES EXISTING INTERIOR/EXTERIOR WALL TO BE DEMOLISHEDKEY PLANEXISTINGLOADING DOCKORLANDO SANFORD INTERNATIONAL AIRPORTTERMINALADDITIONWESTDEMOLITION REQUIREMENTS6. SAWCUT AND REMOVE EXISTING EXTERIOR FLATWORK AND PAVINGAS REQUIRED FOR NEW CONSTRUCTION. FIELD VERIFY EXTENTS OFDEMOLITION REQUIRED TO ENSURE POSITIVE DRAINAGE AWAY FROMTHE BUILDING WHEN CONSTRUCTION IS COMPLETE. EXTENTS OFDEMOLITION SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FORGRAPHIC REPRESENTATION ONLY AND SHALL NOT BE ASSUMED TODELINEATE ACTUAL LIMITS OF DEMOLITION REQUIRED.7. CONDUCT ALL DEMOLITION AND REMOVAL OF DEBRIS AS REQUIREDTO INSURE MINIMUM INTERFERENCE WITH BUILDING/SITE FACILITIESAND OPERATIONS. REMOVE DEMOLISHED MATERIALS FROM SITE ANDLEGALLY DISPOSE OF ALL DEBRIS.8. PROTECT EXISTING PAVING AND STRUCTURES TO REMAIN DURINGDEMOLITION AND CONSTRUCTION.1. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER, AND INSTRICT ACCORDANCE WITH OSHA REGULATIONS.2. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION.THE WORK INCLUDES, BUT IS NOT LIMITED TO, THE DEMOLITION ANDREMOVAL OF PAVING AND FLATWORK, WALLS, PARTITIONS, ROOFING,DOORS, CASEWORK, FIXTURES, PLUMBING, MECHANICAL,REFRIGERATION AND ELECTRICAL ITEMS INCLUDING CONDUITS ANDDUCTWORK AS SHOWN ON THE DRAWINGS OR AS REQUIRED FOR THEINSTALLATION OF THE NEW WORK FOR A COMPLETE JOB.3. WHEN REMOVING EXISTING STRUCTURAL ITEMS, IT IS THECONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING,BRACING AND SUPPORT SYSTEMS TO KEEP THE EXISTING STRUCTUREINTACT AND IN A SAFE CONDITION.4. PRIOR TO EXCAVATION FOR FOUNDATIONS ADJACENT TO THEEXISTING STRUCTURE, PROVIDE ADEQUATE SUPPORT FOR THESUB-BASE TO PREVENT UNDERMINING OF THE EXISTING FOUNDATION.5. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL SLAB DEMOLITIONFOR REQUIRED PLUMBING WHICH IS NOT SHOWN ON THE DEMOLITIONPLAN.2207-14-2017CONFORMED SET183
2423DCELEV.TSC.J.C.J.C.J.C.J.C.J.21-S502 1-S50241-S502 1-S50241-S502 1-S50231-S502 1-S50231-S502 1-S50231-S502 1-S50251-S502 1-S50223.5C.2EQ.EQ.3'-6"61-S502 1-S502#5 CONT @ 12" OC1'-0"2'-0" MIN#4 DWL @ 18" OC6"MIN.W/6X6-W2.1XW2.1 W.W.F.#4 @ 18" OCSTL. COL. BEYONDFOR SIZE & REINF.EXT. PNLS., SUPPORTMEMBERS, AND FRAMING.(MATCH TO EXISTING)SEE PLAN & SCHDL.DEPTH3"CLR"TDS"1'-0"COL. GRIDLINENOTCH EDGE & SLOPE/ARCH. REQUIREMENTS.(MATCH TO EXISTING)ELEV.=0'-0"F.F. LELEV.MATCH TO EXISTING5" SLAB-ON-GRADEW/6x6-W2.1xW2.1 W.W.F.6"2'-0"6"ELEV.=0'-0"F.F. LELEV.6"4 #4 CONT.#5 @ 12" O.C.CONT. METAL TRACK 18 GA.ATTACHED TO CONCRETE SLAB W/ (2)3/16" Ø TAPCONS @ 16" O.C. & (2) #10TEK SCREWS TO WALL STUDS10MIL VAPOR BARRIER(2) #5 CONT.12" OF COMPACTEDSUBGRADE5" SLAB-ON-GRADEW/6x6-W2.1xW2.1 W.W.F.CONT. BONDBREAKEREXISTING ELEVATOR PITCONCRETE WALL (V.I.F.)ELEV.=0'-0"F.F.ELEV.ELEV.=(-5'-0" EXISTING)ELEVATOR PITELEVATOR PIT (EXISTING)7'-6"NEW OPENINGBOXED HEADER (H2)CONNECTION REF. 7/S203EXISTING PORTION OF WALL,CONDUITS AND OTHER WALLPENETRATION TO REMAIN. (V.I.F.)3"HSS4X4X1/46"2'-0"6"ELEV.=0'-0"F.F. ELEV.6"4 #4 CONT.#5 @ 12" O.C.10MIL VAPOR BARRIER(2) #5 CONT.C.2C4X4X4"-16 GA.CLIP WITH (4) 0.145PAF TO STEEL AND (4) #10 TEKSCREWS TO STUD, TYP.6"-18GA. METAL STUDBRACING AT 16" O.C. MAX., TYP.4X4X4"-16 GA.CLIP WITH (4) #10 TEKSCREWS TO BOXED HEADER MK'D H2AND (4) #10 TEK SCREWS TO STUD, TYP.T/STEEL COLUMNEXISTING W18X35BEAM TO REMAIM (V.I.F.)71-S5021-S5028'-6"11"10"10"7"112"112"HSS 4x4x1/4(4) 34"Ø A325 BOLT X 12"-STL. PL. A3610"x10"x34"JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S502.dwg Jul 12, 2017 - 2:32pm daran04-28-2016S12014AS SHOWN1-S5021/4" = 1'-0"1FOUNDATION PLANSECTION2 3/4" = 1'-0"SECTION3 3/4" = 1'-0"SECTION5 3/4" = 1'-0"SECTION4 3/4" = 1'-0"KEY PLANEXISTINGLOADING DOCKORLANDO SANFORD INTERNATIONAL AIRPORTTERMINALADDITIONWESTEXISTING LOADING DOCK FOUNDATION PLANAND DETAILSFIRST FLOOR TOP OF SLAB REFERENCE = 0'-0". 0'-0" ISFOR REFERENCE ONLY. SEE CIVIL FOR NVGD ELEVATION.1. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOTSHOWN. VERIFY ALL DIMENSIONS W/ ARCHITECTURALDRAWINGS PRIOR TO CONSTRUCTION.2.SEE ARCHITECTURAL AND MECHANICAL DRAWINGSFOR ALL SLEEVES, PIPES, INSERTS AND EMBEDDEDITEMS.3.4.FOUNDATION PLAN NOTESFLOOR CONSTRUCTION: 5" FIN. CONCRETE FLOOR SLAB(f'c=4,000 PSI) W/6x6-W2.1xW2.1 W.W.F.ON 10 MIL VAPORBARRIER .FOUNDATION LEGENDWFX.0 DENOTES CONTINUOUS WALL FOUNDATION. REFER TO SCHEDULE FOR DIMENSION AND REINFORCEMENT.CJ DENOTES CONTRUCTION JOINTS.TS DENOTES THICKNESS SLAB.SECTION6 3/4" = 1'-0"COLUMN BASE PLATE7 3/4" = 1'-0"CONFORMED SET184
LIGHT GAUGE STEEL NOTES:1. THE COLD-FORMED STRUCTURAL FRAMING SHALL BEMANUFACTURED FROM STRUCTURAL QUALITY STEEL HAVINGMINIMUM YIELD STRENGTH OF 33 KSI, FOR ALL GAUGES, OROPTIONAL 50 KSI FOR 16GA AND HEAVIER AND HAVE A MINIMUMPROTECTIVE COATING EQUAL TO G-60 GALVANIZED FINISH. THESTEEL SHALL CONFORM TO ONE OF THE FOLLOWING ASTMSTANDARDS: ASTM A-653, ASTM A-875, ASTM A-792 OR ASTMA-463. 2.3.2 THE STRUCTURAL FRAMING SHALL MEET ASTMC-955, HAVE ENGINEERING PROPERTIES CALCULATED INCONFORMANCE WITH THE LATEST EDITION OF AISI "SPECIFICATIONSFOR DESIGN OF COLD-FORMED STRUCTURAL STEEL MEMBERS"2. FASTENING OF THE COLD-FORM STRUCTURAL FRAMING SYSTEMSHALL BE ACCOMPLISHED BY SCREWING, POWER ACTUATEDFASTENERS, WELDING OR A COMBINATION OF METHODS. #10SELF-TAPPING SCREWS SHALL BE USED AT ALL CONNECTIONSUNLESS NOTED OTHERWISE.3. ALL METAL STUDS AND TRACKS TO BE 8" X 18 ga., UNLESSSPECIFICALLY NOTED OTHERWISE, WITH 2-#10 SELF TAPPINGSCREWS IN EACH FLANGE AT EACH CONNECTION (4 TOTAL)UNLESS NOTED OTHERWISE.4. ALL EXTERIOR METAL WALL STUDS TO BE LATERALLY BRACED(BRIDGING) AT 4'-0" O.C. MAXIMUM VERTICALLY.TRACK SAME SIZE ASWALL STUDS (TOP & BOTTOM)SEE METAL STUD HEADER SCHEDULE FOR SIZE & GAGEREFER TO SCHEDULESTUDATTACH TRACK TOEACH STUD FLANGEATTACH AT EACH STUDTRACKTRACKATTACH TRACK TOEACH STUD FLANGENOTE: FASTEN BUILT-UP MEMBER ATTACH EACH SIDETRACKBUILT-UP POSTTOGETHER AT 12" O.C. MAXUTILITY CLIP ANGLES(BY DESIGN)JAMB STUDS(BY DESIGN)(1)#10-16 SCREWTYP. EACH FLANGE(2) UNPUNCHED STUDS.(BY DESIGN)RUNNER TRACK(BY DESIGN) ATTACH TOP &BOTTOM TRACKUSING: (2)#10-16SCREWS @ 24"o.c.CRIPPLE STUDSHEADER ATTACHMENTBLOCKINGNOTES:1. BRIDGING FLAT STRAP 2" WIDEx18GA.2. BLOCKING MATCH STUD DEPTH AND GAGE.3. DENOTES BRIDGING LOCATION ON SECTION EQUALLY SPACED BETWEEN SUPPORT, UNO.(1) TEK SCREW ATEACH SIDEFLANGE10'-0" MAX.METAL STUDBRIDGING AT EACH SIDE(4) TEK SCREWS THROUGH BRIDGINGINTO BLOCKING, BOTH SIDESBLOCKING LOCATE AT FIRST SPACEEACH-END AND 10'-0" o/c BETWEENJ1MARKT & B SIDESMEMBERSHAPEBEARINGJAMB SCHEDULE6" 18 GA.TRACKS6" 16 GA.STUDSDTL. 5/1-S503MARKT & B SIDESMEMBERSHAPEBEARINGHEADER SCHEDULEH114 GA.TRACK12" 14 GA.TRACKDTL. 4/1-S503H26" 14 GA.TRACK12" 14 GA.TRACKDTL. 4/1-S503GENERAL NOTES1. LIMITING HEIGHT (UNBRACED HEIGHT) IS THE CLEARDISTANCE FROM THE FINISH FLOOR TO TOP OF WALLOR BRACE LOCATION (HORIZONTAL OR DIAGONALKNEE BRACE).2. ALL METAL STUDS PROPERTIES TO BE ASMANUFACTURED METAL STUD MANUFACTURESASSOCIATIONS PER ICBO REPORT NO. 4943 ORAPPROVED EQUIVALENT. ALLOWABLE UNBRACEDHEIGHT AS PER CHART ABOVE.3. ALL CONNECTION AND FASTENERS TO BE AS PERDETAILS. ALL MANUFACTURERS AND ICBO REPORT #TO BE STRICTLY ADHERED TO BY GC UNLESSAPPROVAL FOR EQUAL SUBSTITUTION IS RECEIVEDFROM VPI.4. ALL GYP BOARD TO BE 5/8" TYPE "X" ON ALLPARTITIONS THROUGHOUT. ATTACH WITH 1" TYPE "S"DRYWALL SCREWS 12" O,C, VERTICALLY AT STUDSAND 8" O.C. AROUND PERIMETER UNLESS NOTEDOTHERWISE.INTERIOR STUD FRAMING NOTES:1. LIMITING HEIGHT FOR 5/8" GYP PANELS AND 5 PSFUNIFORM LOAD PERPENDICULAR TO PARTITION ORFURRING.2. USE ONE-LAYER HEIGHTS FOR UNBALANCED ASSEMBLIES.USE TWO LAYER HEIGHTS FOR MULTI-LAYER ASSEMBLIES.3. FOR FURRING STUD ATTACHED TO TOP AND BOTTOMRUNNERS AND FREE-STANDING UP TO 12'-0" HEIGHT.4. STUDS EXCEEDING 12'-0" HEIGHT REQUIRE MID-HEIGHTANCHOR TO EXTERIOR WALL. ASSEMBLIES WITHOUT FACEPANELS AND CHASE WALLS PARTITIONS REQUIREVERTICAL CROSS BRACES 4'-0" O.C. MAX. LIMITINGCRITERIA D-DEFLECTION, F-BENDING STRESS, V-ENDREACTION SHEAR.5. THE TYPICAL PHYSICAL AND STRUCTURAL PROPERTIESAND APPLICABLE TABLES PUBLISHED WITH THIS CHARTREPRESENT CHARACTERISTICS AND/OR STEEL STUDSCURRENTLY AVAILABLE FROM A GROUP OF STEEL STUDMANUFACTURERS.6. GENERAL CONTRACTOR TO CONSULT STUDMANUFACTURER FOR ACTUAL PHYSICAL AND STRUCTURALPROPERTIES, STUD THICKNESS AND LIMITING EIGHTTABLES TO DETERMINE FINAL STUD SELECTION.6"1625'-0"6"1824'-0"6"2021'-0"4"1619'-0"4"1818'-0"4"2016'-0"3 5/8"1618'-0"1816'-0"2014'-0"3 5/8"3 5/8"GAUGELIMITING/UNBRACED HEIGHTSIZEINTERIOR METAL STUD FRAMING CHARTJ1H1J1FOR EXTERIOR DOORDIMENSION REFER TO ARCH DRAWINGSFOR EXTERIOR DOOR H.T.REFER TO ARCH DRAWINGSJ1H1J1FOR EXTERIOR DOORDIMENSION REFER TO ARCH DRAWINGSFOR EXTERIOR DOOR H.T.REFER TO ARCH DRAWINGSH1H1J1J1FOR FIXED GLASS WINDOWDIMENSION REFER TO ARCH DRAWINGSFOR FIXED GLASS WINDOW H.T.REFER TO ARCH DRAWINGSMARKREMARKTRACK SCHEDULET18" 14 GA. TRACKSATTACHED TO J2 MEMBER & SPACINGSHAPEW/ 6X6 14 GA CLIPS6#10 TEKS TO TRACK6#10 TEKS TO JAMBJOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S503.dwg Jul 12, 2017 - 2:32pm daranS12014AS SHOWN1-S5031/4" = 1'-0"1NEW DOOR OPENING FRAMING ELEVATION (TYPICAL)1/4" = 1'-0"2WINDOW FRAMING ELEVATION (TYPICAL)3/4" = 1'-0"3TYPICAL STUDS IN PLACE3/4" = 1'-0"4TYPICAL BOXED HEADER CONNECTION3/4" = 1'-0"5TYPICAL BUILT UP POST (JAMB)3/4" = 1'-0"6TYPICAL BRIDGING DETAILTYPICAL LIGHT GAGE FRAMING DETAILS FORDOOR AND WINDOWS07-14-2017CONFORMED SET185
WHERE APPLIESUP TO ROOF LEVEL,CLCOLUMN CONTINUESCAP PL. OF SAME THICKNESS ATREPLACED WITH A CONTINUOUSTOP STIFFENER PLATES SHALL BEBEAM1 1/2"TIGHT CONDITION UNLESSTIGHTENED TO THE SNUG3/4"Ø A325 FIELD BOLTS NOTED OTHERWISE IN STEEL 3/8" THICK SHEAR PL. WITHERECTION NOTES.USE 3/8"THICK MIN.,TYP.TO MATCH BEAM FLANGE,STIFFENER PLATES THICKNESSNOT SHOWN FOR CLARITY)COLUMN (FLANGE CONNECTION3-SIDESAWS3/16"3/16"E70XX1/4"2 5/16"TYPICAL BEAM TO COLUMN WEB MOMENT CONNECTIONSCALE: 1" = 1'-0"ROOF LEVELBOTTOM FLANGESAWS E70XX1/4"B-U4a TOP &3"SEE NOTEN ROWS@3"1-1/2"TYP.W8, W10W12, W14W16,W18,W21,W24,W27,W30,W33, W36N=2N=3N=4N=5N=6N=7N=8N=9N=10(BEAM IS SHOWN FLAT FOR CLARITY. USE 2-1/2"DISTANCE TO FIRST HOLE FOR W8X40, X35, X31, X28, AND FOR 24.USE 3-1/2"DISTANCE TO FIRST HOLE FOR W24X104, X146, & X162.)WHERE APPLIESUP TO ROOF LEVEL,CLCOLUMN CONTINUESCAP PL. OF SAME THICKNESS ATREPLACED WITH A CONTINUOUSTOP STIFFENER PLATES SHALL BEBEAM1 1/2"TIGHT CONDITION ON BEAM UNLESSTIGHTENED TO THE SNUGNOTED OTHERWISE IN STEEL 2-L 4"X4"X3/8"ØA-325 SHOP BOLTSERECTION NOTES.NOT SHOWN FOR CLARITY)COLUMN (FLANGE CONNECTION2-1/16"TYPICAL BEAM TO COLUMN FLANGE SHEAR CONNECTION (Bf=8)SCALE: 1" = 1'-0"ROOF LEVEL3"SEE NOTEN ROWS@3"1-1/2"TYP.W8, W10W12, W14W16, W18W21, W24W27, W30W33,W36,N=2N=3N=4N=5N=6N=7N=8(BEAM IS SHOWN FLAT FOR CLARITY. Bf STANDS FOR COLUMN FLANGE WIDTH.USE 2-1/2"DISTANCE TO FIRST HOLE FOR W8X40,X35, X31, X28, X24, AND C8X18.75, X13.75 & 11.5. USE 3-1/2" DISTANCE TO FIRST HOLE FOR W24X104, X146, & X162CLEAR1/2"TO THE SNUG TIGHT CONDITION ON3/4"ØA-325 FIELD BOLTS TIGHTENEDCOLUMN UNLESS NOTED OTHERWISEIN STEEL ERECTION NOTES,Ga=5-1/2",TYP.WHERE APPLIESUP TO ROOF LEVEL,CLCOLUMN CONTINUESCAP PL. OF SAME THICKNESS ATREPLACED WITH A CONTINUOUSTOP STIFFENER PLATES SHALL BEBEAM1 1/2"TIGHT CONDITION ON BEAM UNLESSTIGHTENED TO THE SNUGNOTED OTHERWISE IN STEEL 2-L 4"X4"X3/8"ØWITH 3/4"ØA-325 SHOP BOLTSERECTION NOTES.2-1/16"A SHEAR CONNECTION AT FLANGE AND FOR W10 AND LARGER COLUMNSSCALE: 1" = 1'-0"ROOF LEVEL3"SEE NOTEN ROWS@3"1-1/4"TYP.W8, W10W12, W14W16, W18W21, W24W27, W30W33,W36,N=2N=3N=4N=5N=6N=7N=8(BEAM IS SHOWN FLAT FOR CLARITY. USE 2-1/2"DISTANCE TO FIRST HOLE FOR WXX40, X35, X31, X28, & X24.USE 3-1/2"DISTANCE TO FIRST HOLEFOR W24X104, X146 & X162.CLEAR1/2"TO THE SNUG TIGHT CONDITION ON3/4"ØA-325 FIELD BOLTS TIGHTENEDCOLUMN UNLESS NOTED OTHERWISEIN STEEL ERECTION NOTES,Ga=5-1/2",TYP.THE SECOND HOLE OF THE BEAM ONSHALL HAVE THE FIRST HOLE MATCHBEAM ON ONE SIDE OF COLUMN WEBTHE OTHER SIDE OF COLUMN TO COMPLYWITH ERECTION SAFETY RULES BY OSHA.THIS IS REQUIRED ONLY WHEN BEAMSSHARE ALL THEIR BOLTS ON THE COLUMNWEB.NOT SHOWN FOR CLARITY)COLUMN (FLANGE CONNECTIONTYPICAL BEAM TO COLUMN WEB SHEAR CONNECTION WHEN THERE IS0"AT ROOF LEVELWHERE APPLIESUP TO ROOF LEVEL,CLCOLUMN CONTINUESCAP PL. OF SAME THICKNESS ATREPLACED WITH A CONTINUOUSTOP STIFFENER PLATES SHALL BEBEAMTIGHT CONDITION ON BEAM UNLESSTIGHTENED TO THE SNUGNOTED OTHERWISE IN STEEL 2-L 4"X4"X3/8"ØA-325 SHOP BOLTSERECTION NOTES.TYPICAL BEAM TO COLUMN FLANGE MOMENT CONNECTION (Bf=8)SCALE: 1" = 1'-0"ROOF LEVEL3"SEE NOTEN ROWS@3"1-1/4"TYP.W8, W10W12, W14W16, W18W21, W24W27, W30W33,W36,N=2N=3N=4N=5N=6N=7N=8(BEAM IS SHOWN FLAT FOR CLARITY. Bf STANDS FOR COLUMN FLANGE WIDTH. USE 2-1/2"DISTANCE TO FIRST HOLE FORW8X40,X35, X31, X28 AND X24. USE 3-1/2"DISTANCE TO FIRST HOLE FOR W 24X104, X146 AND X162.AT FLG.1/4"CLEARTO THE SNUG TIGHT CONDITION ON3/4"ØA-325 FIELD BOLTS TIGHTENEDCOLUMN UNLESS NOTED OTHERWISEIN STEEL ERECTION NOTES,Ga=3-1/2",TYP.BOTTOM FLANGESAWS E70XX1/4"B-U4a TOP &BOTTOM FLANGESAWS E70XX1/4"B-U4a TOP &1-2"CL.@ WEBUSE 3/8"THICK MIN. TYP.TO MATCH BEAM FLANGE,STIFFENER PL'S THICKNESS 1"ABOVE TOSAT ROOF LEVEL(WEB CONNECTION NOT SHOWNFOR CLARITY)WHERE APPLIESUP TO ROOF LEVEL,CLCOLUMN CONTINUESCAP PL. OF SAME THICKNESS ATREPLACED WITH A CONTINUOUSTOP STIFFENER PLATES SHALL BEBEAMWELDED TO BEAM2-L 3"X3"X3/8"ØA-325 SHOPTYPICAL BEAM TO COLUMN FLANGE MOMENT CONNECTION (Bf=8)SCALE: 1" = 1'-0"ROOF LEVEL3"SEE NOTEN ROWS@3"1-1/4"TYP.W8, W10W12, W14W16, W18W21, W24W27, W30W33,W36,N=2N=3N=4N=5N=6N=7N=8(BEAM IS SHOWN FLAT FOR CLARITY. Bf STANDS FOR COLUMN FLANGE WIDTH. USE 2-1/2" DISTANCE TO FIRST HOLE FOR W8X40, X35, X31, X28, X24 AND C8X18.75, X13.75 & 11.5 USE 3-1/2" DISTANCE TO FIRST HOLE FOR W24X104, X146 &162.AT FLG.1/4"CLEARTO THE SNUG TIGHT CONDITION ON3/4"ØA-325 FIELD BOLTS TIGHTENEDCOLUMN UNLESS NOTED OTHERWISEIN STEEL ERECTION NOTES,Ga=3-1/2",TYP.BOTTOM FLANGESAWS E70XX1/4"B-U4a TOP &1-2"CL.@ WEB1"ABOVE TOSAT ROOF LEVEL(WEB CONNECTION NOT SHOWNFOR CLARITY)BOTTOM FLANGESAWS E70XX1/4"B-U4a TOP &CAP PL. OF SAME THICKNESS ATREPLACED WITH A CONTINUOUSTOP STIFFENER PLATES SHALL BEBEAMX LARGEST K DIM.TIGHT CONDITION ON BEAM UNLESSTIGHTENED TO THE SNUGNOTED OTHERWISE IN STEEL 2-L 4"X4"X3/8"ØA-325 SHOP BOLTSERECTION NOTES.2-1/16"TYPICAL BEAM TO GIRDER CONNECTIONSCALE: 1" = 1'-0"ROOF LEVEL3"SEE NOTEN ROWS@3"1-1/4"TYP.W8, W10W12, W14W16, W18W21, W24W27, W30W33,W36,N=2N=3N=4N=5N=6N=7N=8(BEAM IS SHOWN FLAT FOR CLARITY. USE 2-1/2" DISTANCE TO FIRST HOLEFOR W8X40, X35, 31, X28, X24 AND C8X18.75, X13.75 AND 11.5CLEAR1/2"TO THE SNUG TIGHT CONDITION ON3/4"ØA-325 FIELD BOLTS TIGHTENEDCOLUMN UNLESS NOTED OTHERWISEIN STEEL ERECTION NOTES,Ga=5-1/2",TYP.GIRDERS 12BfGIRDERUSE 3-1/2" DISTANCE TO FIRST HOLE FOR W24X104, X146 AND X162).K DIM.WHERE APPLIESUP TO ROOF LEVEL,CLCOLUMN CONTINUESCAP PL. OF SAME THICKNESS ATREPLACED WITH A CONTINUOUSTOP STIFFENER PLATES SHALL BEBEAMTIGHT CONDITION ON BEAM UNLESSTIGHTENED TO THE SNUGNOTED OTHERWISE IN STEEL 2-L 4"X4"X3/8"ØA-325 SHOP BOLTSERECTION NOTES.TYPICAL BEAM TO COLUMN FLANGE MOMENT CONNECTION (Bf=8)SCALE: 1" = 1'-0"ROOF LEVEL3"SEE NOTEN ROWS@3"1-1/4"TYP.W8, W10W12, W14W16, W18W21, W24W27, W30W33,W36,N=2N=3N=4N=5N=6N=7N=8(BEAM IS SHOWN FLAT FOR CLARITY. Bf STANDS FOR COLUMN FLANGE WIDTH. USE 2-1/2"DISTANCE TO FIRST HOLE FORW8X40,X35, X31, X28 AND X24. USE 3-1/2"DISTANCE TO FIRST HOLE FOR W 24X104, X146 AND X162.)AT FLG.1/4"CLEARTO THE SNUG TIGHT CONDITION ON3/4"ØA-325 FIELD BOLTS TIGHTENEDCOLUMN UNLESS NOTED OTHERWISEIN STEEL ERECTION NOTES,Ga=3-1/2",TYP.BOTTOM FLANGESAWS E70XX1/4"B-U4a TOP &BOTTOM FLANGESAWS E70XX1/4"B-U4a TOP &1-2"CL.@ WEBUSE 3/8"THICK MIN. TYP.TO MATCH BEAM FLANGE,STIFFENER PL'S THICKNESS 1"ABOVE TOSAT ROOF LEVEL(WEB CONNECTION NOT SHOWNFOR CLARITY)2-5/16"WHERE APPLIESUP TO ROOF LEVEL,CLCOLUMN CONTINUES3/8" THICK CAP PL. AT ROOF LEVELREPLACED WITH A CONTINUOUSTOP STIFFENER PLATES SHALL BEBEAM1 1/2"TIGHT CONDITION UNLESSTIGHTENED TO THE SNUG3/4"Ø A325 FIELD BOLTS NOTED OTHERWISE IN STEEL 3/8" THICK SHEAR PL. WITHERECTION NOTES.USE 3/8"THICK MIN.,TYP.TO MATCH BEAM FLANGE,STIFFENER PLATES THICKNESSNOT SHOWN FOR CLARITY)COLUMN (FLANGE CONNECTION3-SIDESAWS3/16"3/16"E70XX1/4"2 1/16"WHEN THERE IS A MOMENT CONNECTION AT FLANGE NOT TO SCALE3"SEE NOTEN ROWS@3"1-1/2"TYP.W8, W10W12, W14W16,W18,W21,W24,W27,W30,W33, W36N=2N=3N=4N=5N=6N=7N=8N=9N=10(BEAM IS SHOWN FLAT FOR CLARITY. USE 2-1/2"DISTANCE TO FIRST HOLE FOR W8X40, X35, X31, X28, AND FOR 24.USE 3-1/2"DISTANCE TO FIRST HOLE FOR W24X104, X146, & X162.)REQUIRED.STIFFENER LOCATIONS SHALLBY FLANGE MOMENT CONNECTION WHEN3/8"THICK STIFFENER PL'S OR AS REQUIREDLINE UP WITH NOMINAL BEAM DEPTH ORAS REQUIRED BY FLANGE MOMENTCONNECTIONREQUIRED.STIFFENER LOCATIONS SHALLBY FLANGE MOMENT CONNECTION WHEN3/8"THICK STIFFENER PL'S OR AS REQUIREDLINE UP WITH NOMINAL BEAM DEPTH ORAS REQUIRED BY FLANGE MOMENTCONNECTIONTYPICAL BEAM TO COLUMN WEB MOMENT CONNECTIONAND FOR W8 COLUMNSTYPICAL CONNECTION DETAILS NOTES:1-MATERIAL FOR ALL WIDE FLANGE SECTIONS IS ASTM A992 (Fy=50 ksi)2-MATERIAL FOR ALL ANGLES AND PLATES IS ASTM A36 (Fy=36 ksi)3-ALL SHEAR PLATES HAVE HORIZONTAL SLOTTED HOLES 13/16"X1-1/16"4-ALL CONNECTION ANGLES HAVE HORIZONTAL SLOTTEDHOLES 13/16"X1/16" IN THE OUTSTANDING LEG.JOSE MIGUEL ORTIZ, P.E.Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONJMODASJMOJMOwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAREVISIONS# DATEDESCRIPTIONBYJ:\S12014\Architecture\02_Structural\PHASE I\1-S601.dwg Jul 12, 2017 - 2:29pm daranSTEEL FRAMING CONNECTIONS AND DETAILSAS SHOWNS120141-S60107-14-2017CONFORMED SET186
FIRE ALARM SYMBOLS LEGEND##Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E FirmKSPKSPTTNTTN500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:1/4" = 1'-0"C:\Users\epalmer\Documents\MEP_S12014_03_23_16_epalmer.rvt6/8/2017 2:52:14 PM1-FA-001PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFIRE ALARM GENERAL NOTES AND SYMBOLS04-26-2017S12014REVISIONS#DATEDESCRIPTIONBYCONFORMED SET187
FIRE ALARM RISER DIAGRAMREFER TO SHEET 1-G-FA102 FOR AREA PLAN.2) REFER TO SHEET 1-G-FA103 AREA PLAN.3) REFER TO SHEET 1-FA-001 GENERAL NOTES.CAPACITY AND AHJ.RUN TWO CONDUITS TO MAIN FACP.TERMINATE DEVICES TO THE CLOSEST FIRE ALARMTERMINAL CABINET OR EXISTING J-BOX. TERMINATEDEVICES TO EXISTING OR EXTENDED CIRCUIT PER LOADKEY NOTES:2)REFER TO SHEET 1-G-FA103 AREA PLAN.3)REFER TO SHEET 1-FA-001 GENERAL NOTES.1)REFER TO SHEET 1-G-FA102 FOR AREA PLAN.GENERAL NOTES:GENERALNOTES:Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTIONwww.cphcorp.comArchitects EngineersEnvironmentalLandscape ArchitectsM / E / PPlannersSurveyorsTraffic /TransportationOffices in:FloridaPuerto RicoConnecticutMarylandTexasA Full ServiceA & E Firm500 West Fulton St.Sanford, Fl. 32771Ph: 407.322.6841Licenses:Eng. C.O.A. No. 3215Survey L.B. No. 7143Arch. Lic. No. AA2600926Lndscp. Lic. No. LC0000298CPH, Inc.Plans Prepared By:C:\Users\dkramer\Documents\MEP_S12014_03_23_16_dkramer.rvt7/11/2017 12:28:12 PM1-G-FA002PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDA07-14-2017S12014REVISIONS#DATEDESCRIPTIONBYCPHCPHT NASHT NASHAS NOTEDCONFORMED SET188
CONFORMED SET189
CONFORMED SET190
CONFORMED SET191
F
C
C
C
C
C
S S S S S S S
C
C
C
C
C
C
C
C
C
C
C
C C C
B16 B15 B14 B13 B12
BH
BF
A B11
BE1
BH.1
BH.2
BH.3EXISTING MECHANICAL ROOM
B2-01
CORRIDOR
B2-18
SECURITY OFFICE
B2-08SECURITY EXIT
B2-02
RECEPTION
B2-10
ELEVATOR 3
B1-48
OPPS MANAGER OFFICE
B2-11MENS ROOM
B2-05
WOMENS ROOM
B2-04
500 West Fulton St.
Sanford, Fl. 32771
Ph: 407.322.6841
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Arch. Lic. No. AA2600926
Lndscp. Lic. No. LC0000298
CPH, Inc.Plans Prepared By :Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.
NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Surveyors
Traffic /
Transportation
Offices in:
·Florida
·Puerto Rico
·Connecticut
·Maryland
·Texas
A Full Service
A & E Firm
1/8" = 1'-0"C:\Users\dkramer\Documents\MEP_S12014_03_23_16_dkramer.rvt9/13/2017 10:43:40 AM1-GD-FA101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDADEMOLITION FLOOR PLAN - PHASE 1 - FIRE ALARM08-11-2017S12014CPHCPHT NASHT NASHAS NOTED 1/8" = 1'-0"1 DEMOLITON FLOOR PLAN - PHASE 1 - FIRE ALARM - SECOND FLOOR
1
KEY NOTES:
1) REFER TO SHEET 1-G-FA102 FOR AREA PLAN.
2) REFER TO SHEET 1-G-FA001 GENERAL NOTES.
3) REFER TO SHEET 1-G-FA002 RISER DIAGRAM.
GENERAL NOTES:
REMOVE DEVICES, ASSOCIATED JUNCTION
BOXES, CONDUIT AND WIRING BACK TO
NEAREST JUNCTION BOX THAT IS TO
REMAIN. EXISTING DEVICES SHALL BE
CLEANED, TESTED AND VERIFIED IN GOOD
WORKING CONDITION FOR REUSE.
DAMAGED DEVICES TO BE REPLACED BY
SIMILAR TYPE AND COLOR. INTERCEPT AND
EXTEND CONDUIT AND WIRING TO NEW
LOCATION AND CONNECT TO EXISTING
DEVICE TO BE REUSED.
1
1
1
1
REVISIONS#DATEDESCRIPTIONBY509/15/2017ADDENDUM 5ENTIRE SHEET REVISED5
CONFORMED SET
192
CONFORMED SET193
2
2
3
1
1F75CDF75CD
75C D
7 5 C D
7 5 C D
7 5 C D75CD75CD
W P
F75CDF75CDF75CD7 5C D 75C DF
75CD75CD75CD75CD75CD75CD75CD75CDRR75CD75CDVTWFAIMAIMC1
CA
LOADING DOCK
LD-1
BADGING
LD-5
RESTROOM
LD-7
CHIEF
LD-20
BREAK ROOM
LD-21
IT
LD-16
CORRIDOR
LD-14
INTERVIEW
LD-10
RECEPTION
LD-8
STORAGE
LD-17
ARMS
LD-15
OFFICE
LD-18
OFFICE
LD-6
STORAGE
LD-9
HVAC
LD-4
RESTROOM
LD-2
HVAC
LD-11
SHOWER
LD-12
RESTROOM
LD-13
500 West Fulton St.
Sanford, Fl. 32771
Ph: 407.322.6841
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Arch. Lic. No. AA2600926
Lndscp. Lic. No. LC0000298
CPH, Inc.Plans Prepared By :Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.
NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Surveyors
Traffic /
Transportation
Offices in:
·Florida
·Puerto Rico
·Connecticut
·Maryland
·Texas
A Full Service
A & E Firm
E.PALMERE.PALMERT.NASHT.NASH 1/8" = 1'-0"C:\Users\dkramer\Documents\MEP_S12014_03_23_16_dkramer.rvt9/8/2017 7:36:16 AM1-LD-FA100PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFLOOR PLAN - NEW LOADING DOCK - FIRE ALARM08-11-2017S12014N
ORLANDO SANFORD INTERNATIONAL AIRPORT
KEY PLAN
NEW LOADING
DOCK
BUILDING OUTBOUND F.I.S. /
CUSTOMS
INBOUND
1
KEY NOTES:
1) REFER TO SHEET 1-G-FA101 FOR AREA PLAN.
2) REFER TO SHEET 1-G-FA001 GENERAL NOTES.
3) REFER TO SHEET 1-G-FA002 RISER DIAGRAM.
GENERAL NOTES:
COORDINATE EXACT LOCATION AND
REQUIREMENTS WITH FIRE SPRINKLER
CONTRACTOR.
CONTROL RELAY FOR FIRE STAT.
COORDINATE EXACT LOCATION AND
REQUIREMENT WITH MECHANICAL
CONTRACTOR.
RUN TWO 3" CONDUIT TO MAIN FACP.CPHCPHT NASHT NASHAS NOTED 1/8" = 1'-0"1 FLOOR PLAN - NEW LOADING DOCK - PHASE 1 - FIRE ALARM
2
3
REVISIONS#DATEDESCRIPTIONBY09/08/2017ADDENDUM 4CONFORMED SET
194
CONFORMED SET195
CONFORMED SET196
CONFORMED SET197
CONFORMED SET198
CONFORMED SET199
CONFORMED SET200
CONFORMED SET201
CONFORMED SET202
CONFORMED SET203
CONFORMED SET204
HYDRAULIC DESIGN DATA
SPRINKLER PIPING (ABOVE GRADE)
FIRE MAIN (BELOW GRADE)
SIDEWALL SPRINKLER
EXT. COVERAGE
UPRIGHT SPRINKLER
SIDEWALL SPRINKLER
SIDEWALL SPRINKLER
PENDANT SPRINKLER
SPRINKLER TYPE
PENDANT SPRINKLER
COMBINATION SPRINKLER RISER
FIRE SPRINKLER LEGEND
212°
165°
212°
165°
165°
TEMP.
165°
FL
FM
SYMBOL RESPONSE
NONE
PLATE
ESCUTCHEON
SEMI-RECESSED
SEMI-RECESSED
CONCEALED
SEMI-RECESSED
CHROME 1/2" 5.6
FINISH
CHROME
CHROME
CHROME
CHROME
CHROME
7/16"
1/2"
1/2"
4.1
5.6
5.6
1/2"
SIZE
1/2"
5.6
K
5.6
QUICK
QUICK
QUICK
QUICK
QUICK
QUICK
KEY NOTE
AIR COMPRESSOR SCHEDULE
MAXIMUM DISTANCE BETWEEN HANGERS
NOMINAL PIPE SIZE
(STEEL PIPE)
1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 4" 6"
12'-0" 12'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0"
FIRE SPRINKLER HAZARD CLASSIFICATION OF ROOM
EXISTING STRUCTURAL FIREPROOFING REPAIR STRUCTURAL DELEGATED DESIGN
1. FIRE PROTECTION SYSTEM SHALL COMPLY WITH THE LATEST EDITION OF NFPA # 12A, 13,
14, 15, 24, 25, 70, 72, 75, & 101, LOCAL FIRE MARSHALS OFFICE, OWNERS INSURANCE CARRIER,
ALL APPLICABLE STATE, LOCAL AND FEDERAL CODES AND REGULATIONS AND ANY OTHER
AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT. THIS SYSTEM SHALL BE INSTALLED
BY A STATE OF FLORIDA CERTIFIED FIRE PROTECTION CONTRACTOR SKILLED AND LICENSED
IN THIS PARTICULAR TRADE.
2. CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC
CALCULATIONS FOR APPROVAL BY THE AUTHORITIES HAVING JURISDICTION AND ENGINEER
PRIOR TO COMMENCEMENT OF ANY WORK. THE DOCUMENTS SHALL BE PREPARED IN
ACCORDANCE WITH THE REQUIREMENTS OUTLINED IN THESE DRAWINGS AND
SPECIFICATIONS AND ALL APPLICABLE CODES ADOPTED BY THE STATE OF FLORIDA.
3. THE CONTRACTOR SHALL CONDUCT A HYDRANT FLOW TEST, WHICH SHALL BE THE BASIS
FOR THE HYDRAULIC CALCULATIONS. CONTRACTOR SHALL EVALUATE THE WATER SUPPLY
FOR EVIDENCE OF MICROBIAL INDUCED CORROSION (MIC) AND INCORPORATE ANY
PREVENTIVE MEASURES AS REQUIRED.
4. THE CONTRACTOR SHALL PROVIDE ALL PERMITS, MATERIAL, LABOR, TRUCKING, HOISTING,
ENGINEERING, SCAFFOLDING, POWER HOOK UPS, PROTECTION, SHOP DRAWINGS, TAXES,
LAYOUT, EQUIPMENT, SUPERVISION, INSURANCE, ETC. NECESSARY FOR THE FURNISHING
AND INSTALLATION OF ALL SPECIFIED AND RELATED WORK IN ACCORDANCE WITH THE
CONTACT DRAWINGS AND SPECIFICATIONS.
5. THIS CONTRACTOR SHALL OBTAIN FINAL INSPECTION AND APPROVAL BY LOCAL FIRE
DEPARTMENT, BLDG. DEPT., OWNERS INSURANCE CARRIER AND ARCHITECT/ENGINEER.
6. PROVIDE DETAIL AND INDICATE TYPE OF HANGERS TO BE INSTALLED FOR SPRINKLER
PIPING. METHODS OF HANGING PIPES, HEADERS AND BRANCHES SHALL BE IN ACCORDANCE
WITH N.F.P.A. 13. ALL HANGERS ON 4" PIPE AND LARGER SHALL BE CLEVIS-TYPE HANGERS.
HANGERS SHALL NOT INTERFERE WITH ANY OTHER TRADE. POWDER DRIVEN STUDS SHALL
NOT BE USED. ALL PIPING SUPPORTS AND HANGERS SHALL BE CORROSION RESISTANT,
SIZED AND SPACED IN ACCORDANCE WITH NFPA #13 .
7. BEFORE SUBMITTING PROPOSAL OR BID, EXAMINE ALL DRAWINGS AND SPECIFICATIONS
RELATING TO THIS PROJECT, THE AMOUNT OF SPACE AVAILABLE FOR PIPING, EQUIPMENT
AND CONNECTING SERVICES, THE SCOPE OF SITE OF THE WORK, THE REQUIREMENTS TO
CORRELATE THE FIRE PROTECTION WORK WITH THAT OF OTHER TRADES AND THE TIME
SCHEDULE NECESSARY TO PERFORM THAT WORK. CONTRACTOR SHALL VISIT THE SITE TO
CHECK AND VERIFY ALL EXISTING CONDITIONS PRIOR TO BIDDING TO INSURE THE
COORDINATION OF THE FIRE SERVICES WITH EXISTING CONDITIONS. IN CASE OF DISPUTE OR
DOUBT AS TO INTENT OF DRAWINGS OR SPECIFICATIONS, OBTAIN ARCHITECT/ENGINEER'S
WRITTEN DECISION BEFORE PROCEEDING WITH BID OR WORK INVOLVED.
8. IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND
BETWEEN THESE PLANS, OTHER ENGINEERING PLANS, THE ARCHITECTURAL PLANS AND/OR
FIELD CONDITIONS PRIOR TO FINAL BID PRICE OR FINAL PERMITTING.
9. INDICATE CENTER TO CENTER DIMENSIONS AND/OR PIPE CUT LENGTHS AND NOMINAL PIPE
DIAMETERS ON ALL PIPING. INDICATE PIPE TYPE, SCHEDULE OF WALL THICKNESS AND
METHOD OF JOINING ON SHOP DRAWING.
10. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS SHALL BE DONE ONLY
WITH THE WRITTEN APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER.
11. VERIFY STRUCTURAL, MECHANICAL, ELECTRICAL INSTALLATIONS AND AVOID ANY / ALL
OBSTRUCTIONS OR INTERFERENCES WITH FIRE PROTECTION PIPE ROUTING.
12. ALL MATERIALS, WHERE APPLICABLE, SHALL BE U.L. LISTED AND FACTORY MUTUAL
APPROVED FOR USE IN AUTOMATIC SPRINKLER SYSTEMS. ALL NEW PIPING SHALL BE
HYDROSTATICALLY TESTED FOR TWO HOURS IN ACCORDANCE WITH NFPA #13. HYDROSTATIC
TEST PRESSURE SHALL BE 200 PSI.
13. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, CEILINGS, FLOORS, ROOFS, ETC.,
FLASH AND COUNTERFLASH ROOF PENETRATIONS. (SEE FIRE RATED PIPE PENETRATION
DETAILS ON ARCHITECTURAL SHEETS).
14. COORDINATE ALL PIPE ROUTING WITH ALL OTHER TRADES TO AVOID DUCTWORK,
LIGHTING, PIPING AND ANY BUILDING STRUCTURE , ROUTE ALL PIPING CONCEALED ABOVE
CEILING, WITHIN CHASES OR CONCEALED WITHIN WALLS.
15. WELD-O-LETS SHALL BE TWO SIZES SMALLER THAN CROSSMAIN, NO LENGTH OF
CROSSMAIN SHALL BE GREATER THAN 10'-0". ALL SPRINKLER PIPING & FITTINGS SHALL BE
INSTALLED ABSOLUTELY RUST-FREE.
16. ALL SPRINKLER DROPS SHALL BE 1" SCHEDULE 40 BLACK STEEL PIPE WITH 1" X 1/2"
THREADED REDUCER.
17. PIPE SHALL BE REAMED AND CLEANED BEFORE ASSEMBLY, AND AFTER ASSEMBLY THE
ENTIRE PIPING SYSTEM SHALL BE FLUSHED CLEAN.
18. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON-ACCESSIBLE CEILINGS AND
CHASES.
19. PROVIDE SYSTEM(S) WITH FLUSHING CONNECTION(S).
20. INSPECTOR'S TEST VALVE SHALL NOT EXCEED 7 FEET ABOVE THE FINISHED FLOOR.
PROVIDE SMOOTH BORE CORROSION RESISTANT OUTLET FOR INSPECTOR'S TEST GIVING
FLOW EQUIVALENT TO 1 SPRINKLER.
21. THIS CONTRACTOR SHALL ASSIST IN PREPARATION OF COORDINATION DRAWINGS FOR ALL
LEVELS WHICH INDICATE ALL THE ENGINEERING DISCIPLINES & FIRE PROTECTION PIPING.
22. FIRE SPRINKLER PIPING SHALL NOT TRAVEL OVER THE TOPS OF ELECTRICAL PANEL
BOARDS.
23. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHTS IN EACH AREA.
24. WET SYSTEM PIPING SHALL BE INSTALLED LEVEL TO DRAIN BACK TO THE SYSTEM RISER,
IN ACCORDANCE WITH NFPA #13, 4-14.3.2. TRAPPED SECTIONS OF PIPING SHALL HAVE
AUXILIARY DRAIN CONNECTIONS IN ACCORDANCE WITH 4-14.3.5
25. AUTOMATIC SPRINKLER TEMPERATURE RATINGS OF FUSIBLE ELEMENTS SHALL BE IN
ACCORDANCE WITH N.F.P.A. 13. ALL SPRINKLERS SHALL HAVE CORROSIVE RESISTANT
COATING WHERE EXPOSED TO ELEMENTS.
26. SPRINKLERS SHALL COVER THE ENTIRE AREA OF ALL STRUCTURAL MEMBERS. THE SPRAY
PATTERN ON ANY SPRINKLER SHALL NOT BE BLOCKED BY WALL, PARTITIONS OR
STRUCTURAL COMPONENTS.
27. ALL PENDENT SPRINKLERS SHALL BE CENTER OF TILE, UNLESS MAXIMUM DISTANCES
FROM WALLS OR BETWEEN HEADS IS EXCEEDED. IF NOT POSSIBLE ALL SPRINKLER HEADS
MOUNTED IN CEILING SHALL BE LOCATED A MINIMUM OF 4" AWAY FROM ANY WALLS, CEILING
GRID MEMBERS, CEILING HEIGHT CHANGES OR ANY OTHER VERTICAL INTERSECTING
STRUCTURAL SURFACE.
28. PROVIDE STOCK OF EXTRA SPRINKLERS IN ACCORDANCE WITH N.F.P.A. # 13.
29. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK 4 FEET OR WIDER.
30. PROVIDE HAZARD COVERAGE FOR THE FUNCTIONS FOR EACH AREA AS INDICATED ON
PLANS OR REQUIRED BY NFPA.
31. INDICATE THE LOCATION AND SIZE OF BLIND SPACES AND CLOSETS.
32. PROVIDE HEAD GUARDS ON SPRINKLER HEADS IN ELECTRIC, TELEPHONE, AND
MECHANICAL ROOMS.
33. SPRINKLER HEADS SHALL BE INSTALLED IN FULL ACCORDANCE WITH THE MANUFACTURES
GUIDE LINES.
34. CONTRACTOR SHALL PERFORM A HYDROSTATIC TEST OF THE SPRINKLER SYSTEM IN
ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13. NOTIFY THE ARCHITECT, ENGINEER,
OWNER AND UNDERWRITER PRIOR TO PERFORMING THE TEST WHO, AT THEIR OPTION, MAY
DESIRE TO WITNESS THE TEST. TEST SHALL BE SATISFACTORY TO THE ARCHITECT,
ENGINEER, OWNER, UNDERWRITER OR AUTHORITIES HAVING JURISDICTION. AFTER TESTING
HAS BEEN COMPLETED, ALL VALVES SHALL BE LEFT IN THEIR RESPECTIVE NORMAL
POSITIONS, AND THE OWNER AND HIS DULY APPOINTED REPRESENTATIVE SHALL BE
INSTRUCTED IN THE CARE, OPERATION AND MAINTENANCE OF THE ENTIRE SYSTEM. ALL
MATERIAL AND TEST CERTIFICATE SHALL BE COMPLETED AND TURN OVER TO THE OWNER'S
REPRESENTATIVE AT THAT TIME.
35. FLUSHING CONNECTIONS TO BE PROVIDED AT REMOTE ENDS OF ALL CROSS MAINS.
36. PROJECT SPECIFICATIONS TAKE PRECEDENT OVER PLANS.
37. VERIFY UNDERGROUND FIRE MAIN LOCATIONS AND SIZE OF FIRE MAIN REQUIRED WITH
PROJECT SITE PLAN.
38. UNFORESEEN CONDITIONS MAY EXIST. COOPERATION WITH OTHER TRADES IN ROUTING
AND/OR BURIAL DEPTHS AS DETERMINED DURING CONSTRUCTION AND AS DIRECTED BY THE
ARCHITECT MAY BE NECESSARY. IT IS INTENDED THAT SUCH DEVIATIONS SHALL BE
CONSIDERED AS PART OF THIS CONTRACT. THIS CONTRACTOR IS TO FIELD VERIFY
DIMENSIONS OF ALL SITE UTILITIES, ETC., PRIOR TO BID AND INCLUDE ANY DEVIATIONS IN THE
CONTRACT.
39.THE CONTRACTOR WILL INSTALL A FIRE SAFETY PROGRAM TO ADDRESS ALL THE REQUIREMENTS
SPECIFIED IN THE FLORIDA FIRE PREVENTION CODE, INCLUDING NFPA 241. THIS PROGRAM SHALL BE
EFFECTIVE FOR THE DURATION OF ALL DEMOLITION, ALTERATION AND CONSTRUCTION OPERATIONS.
40.WORK SHALL BE PERFORMED, IN STRICT COMPLIANCE WITH THE ESTABLISHED WORK
SCHEDULE BEING SET FORTH BY OWNER. COORDINATE ALL WORK WITH GENERAL
CONTRACTOR. THIS CONTRACTOR SHALL FURNISH ADEQUATE FORCES, CONSTRUCTION
PLANT AND EQUIPMENT, AND SHALL WORK SUCH HOURS, INCLUDING NIGHT SHIFTS,
OVERTIME OPERATIONS, SUNDAYS AND HOLIDAYS IN ACCORDANCE WITH THE OWNER'S
OPERATIONAL SCHEDULE AS LISTED IN DIVISION 1 OF THE SPECIFICATIONS. IF THE
CONTRACTOR DOES NOT MAINTAIN THE CONSTRUCTION SCHEDULE BECAUSE OF
INADEQUATE FORCES, SUPERVISION OR ANY OTHER REASON UNDER THE CONTRACTOR'S
CONTROL, THE OWNER MAY REQUIRE THE CONTRACTOR TO INCREASE THE NUMBER OF
SHIFTS AND/OR OVERTIME OPERATIONS, DAY OF WORK AND/OR THE AMOUNT OF
CONSTRUCTION PLANT, AT NO ADDITIONAL COST TO THE OWNER UNDER THIS CONTRACT.
FAILURE TO MAINTAIN THE CONSTRUCTION SCHEDULE DUE TO OWNER'S OPERATIONAL
INTERFERENCE'S, WHICH WERE NOT IDENTIFIED IN OR PRIOR TO THE PRE-BID CONFERENCE,
SHALL NOT BE THE CONTRACTOR'S LIABILITY.
40. THE EXISTING FIRE SPRINKLER SYSTEM SHALL REMAIN IN OPERATION DURING THE
CONSTRUCTION PHASE OR PROVIDE A FIRE WATCH 24-HOUR / 7-DAYS A WEEK PER THE AHJ
(AUTHORITY HAVING JURISDICTION) REQUIREMENTS.
41. ALL HANGERS AND SUPPORTS SHALL BE OF THE PRE-ENGINEERED TYPE, B-LINE, ANVIL, OR EQUAL.
SIZING AND SPACING SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS AND
INSTALLATION GUIDELINES FOR THE APPLICATIONS INDICATED WITHIN THE DESIGN DOCUMENTS.
WHERE INDICATED PRODUCT NUMBERS ARE TO ESTABLISH MINIMUM ACCEPTABLE STANDARD FOR
THAT APPLICATION. PRIOR TO INSTALLATION THE CONTRACTOR SHALL SUBMIT, FOR ENGINEERS
APPROVAL, DETAILED PLACEMENT DRAWING FOR THE PROJECT TO INCLUDE PRODUCT NUMBERS,
SIZE, AND SPACING ALONG WITH SUPPORTING MANUFACTURERS DOCUMENTATION. HANGER AND
SUPPORTS SYSTEMS SHALL NOT BE INSTALLED PRIOR TO THE ENGINEERS APPROVAL.UNIT NO. LOCATION SERVICE TYPE OUTPUT CAP
SCFM
OPER. PRES.
PSIG
ELECTRICAL
BASIS OF DESIGN NOTES
HP VOLTS PHASE HZ
1-BC3-AC-1 NEW FIRE RISER
ROOM
BC3 AND EXISTING
CANOPY SINGLE STAGE 30 120 5 460 3 60
GENERAL AIR PRODUCTS
MODEL LT2500500 ALL
NOTES:
1. TANK MOUNTED COMPRESSOR.
2. PROVIDE WITH MAGNETIC LINE STARTER MODEL MGXOB.
3. SINGLE POINT ELECTRICAL CONNECTION.
OCCUPANCY CLASSIFICATION
DESIGN AREAS
MAXIMUM COVERAGE
TEMPERATURE RATING
DENSITY GPM/SQ. FT.
HOSE STREAM
LIGHT HAZARD
A) OFFICES AND SIMILAR USE SPACE, RESTROOMS,
AND CORRIDORS.
225 SQ. FT. PER SPRINKLER
ORDINARY 155°, QUICK RESPONSE
0.10 GPM OVER 1500 SQ. FT.
100 GPM / DURATION 30 MINUTES
F1
OCCUPANCY CLASSIFICATION
DESIGN AREAS
MAXIMUM COVERAGE
TEMPERATURE RATING
DENSITY GPM/SQ. FT.
HOSE STREAM
ORDINARY HAZARD GROUP 2
A) GENERAL STORAGE AREAS, (STORAGE LESS
THAN 12' AND QUANTITY AND ARRANGEMENT NOT
EXCEEDING THE LIMITATIONS OF MISCELLANEOUS
STORAGE) B) CUSTODIAL ROOMS, C) MERCANTILE,
D) LOADING DOCK, E) BAGGAGE HANDLING.
130 SQ. FT. PER SPRINKLER
ORDINARY 155°, QUICK RESPONSE
0.20 GPM OVER 1500 SQ. FT.
250 GPM / DURATION 60-90 MINUTES
PROJECT LOCATION: ORLANDO-SANFORD INTERNATIONAL PROJECT NAME: PROJECT ALPHA ONE
(TERMINAL EXPANSION)
PROJECT INFORMATION
61G15-32 COMPLIANCE NOTES
61G15-32.003
1. SPRINKLER SYSTEM LAYOUT SHALL BE SUBMITTED BY A STATE OF FLORIDA LICENSED FIRE PROTECTION CONTRACTOR. THIS BUILDING SHALL BE FULLY SPRINKLED BY A
WET AND DRY PIPE SPRINKLER SYSTEM. CONTRACTOR SHALL LAYOUT AND PROVIDE AUTOMATIC WET PIPE FIRE SPRINKLER SYSTEM ALL APPLICABLE CODES SET FORTH BY
THE AUTHORITY HAVING JURISDICTION. DISCHARGE FROM INDIVIDUAL HEADS IN THE HYDRAULICALLY MOST REMOTE/DEMANDING AREA SHALL BE HYDRAULICALLY
CALCULATED TO AN ACCEPTABLE MARGIN OF SAFETY NOT LESS THAN 10 PSI FOR GROWTH AND FLUCTUATION IN AVAILABLE SUPPLY OF AREA. FIRE SPRINKLER SYSTEM
SHALL INCLUDE MATERIALS, ACCESSORIES, AND EQUIPMENT INSIDE AND OUTSIDE THE BUILDING TO PROVIDE A COMPLETE AND READY FOR USE SPRINKLER SYSTEM.
LAYOUT AND PROVIDE THE SPRINKLER SYSTEM TO GIVE FULL CONSIDERATION TO BLIND SPACES, PIPING, ELECTRICAL EQUIPMENT, DUCTS, HVAC EQUIPMENT, ACCESS
SPACE NEEDED FOR MAINTENANCE OF EQUIPMENT AND OTHER CONSTRUCTION AND EQUIPMENT IN ACCORDANCE WITH DETAILED WORKING DRAWINGS TO BE SUBMITTED
FOR APPROVAL. LOCATE SPRINKLER HEADS IN A CONSISTENT PATTERN WITH CEILING GRID, LIGHTS, DIFFUSER, REGISTERS, GRILLES AND ARCHITECTURAL FEATURES.
DEVICES AND EQUIPMENT FOR FIRE PROTECTION SERVICES SHALL BE U.L. LISTED AND F.M. APPROVED FOR USE IN WET PIPE SYSTEM.
2. THE AUTOMATIC FIRE SUPPRESSION SYSTEM SHALL BE TESTED IN ACCORDANCE WITH NFPA 13, CHAPTER 16 AND NFPA 25.
3. REFER TO HYDRAULIC DESIGN DATA LEGEND FOR HAZARD CLASSIFICATIONS AND REQUIRED DENSITIES..
4. 1) FLORIDA FIRE PREVENTION CODE, 2014
2) NFPA 13, 2010
3) NFPA 24, 2010
4) NFPA 25, 2014
5) FLORIDA BUILDING CODE, 2014
6) FLORIDA ADMINISTRATIVE CODE 61G15-32.003 AND 61G15-32.004
7) LOCAL AND COUNTY CODES SET FORTH BY AUTHORITY HAVING JURISDICTION
5. NO ADDITIONAL STRUCTURAL SUPPORT SHOULD BE REQUIRED, EXCEPT FOR AREAS NOTED ON SHEET 1-SA-FP101 AND PORTIONS OF 1-BC3-FP100.
61G15-32.004
2A THIS PHASE COVERS BOTH AN EXISTING WET AND DRY PIPE SYSTEMS AS WELL AS NEW WET AND DRY PIPE SYSTEMS WITH A NEW POINT OF SERVICE FOR THE NEW SYSTEM.
REFER TO CIVIL PLAN FOR NEW POINT OF SERVICE.
2B INSTALLATION SHALL BE IN ACCORDANCE WITH N.F.P.A. 13, 2013 ED. FIRE PREVENTION CODE 2014, STATE AND LOCAL AUTHORITIES.
2C REFER TO HYDRAULIC DESIGN DATA LEGEND ON FLOOR PLANS.
2D REFER TO 61G15-32.003 COMPLIANCE NOTE #1 AND HYDRAULIC DESIGN DATA LEGEND ON FLOOR PLANS.
2E NEW 6" UNDERGROUND BUILDING FIRE SUPPLY MAIN TAPS INTO AN EXISTING 10" WATER MAIN.
FLOW TEST NOTE:
CONTRACTOR SHALL PERFORM OR OBTAIN A CURRENT FLOW TEST FROM THE LOCAL UTILITIES PRIOR TO THE LAYOUT OF SHOP DRAWINGS. DATE OF FLOW TEST SHALL NOT
EXCEED 6 MONTHS TO THE SUBMISSION OF SHOP DRAWINGS. FLOW TEST SHALL INCLUDE ALL INFORMATION AS INDICATED BELOW
2F
HYDRANT ID -
FLOW TEST DATE/TIME 07/26/2016 / 3:17 PM
HYDRANT LOCATION -
STATIC GAUGE PRESSURE 52 PSI
RESIDUAL GAUGE PRESSURE 42 PSI
FLOW RATE: 1,030 GPM
SOURCE OF INFORMATION: CPH ENGINEERS
2G ALL VALVES CONTROLLING WATER SUPPLY SHALL HAVE A RED TAMPER PROOF COVER WHICH WILL ACTIVATE AN ALARM OF TROUBLE SIGNAL WHEN ADJUSTED.
2H VERIFY THAT UTILITY PURVEYOR CONTINUOUSLY MONITORS THE WATER SUPPLY FOR MICRO BIOLOGICAL CONTAMINANTS WITH MAY CAUSE MICROBIAL CORROSION.
2I EXISTING BUILDING SPRINKLER SYSTEM BACKFLOW HAS NOT CHANGED. NEW BUILDING SPRINKLER SYSTEM IS PROVIDED WITH A NEW BACKFLOW. REFER TO CIVIL DRAWINGS.
2J ALL YARD AND INTERIOR FIRE PROTECTION COMPONENTS SHALL BE NEW U.L. LISTED AND FM APPROVED.
OCCUPANCY CLASSIFICATION
DESIGN AREAS
MAXIMUM COVERAGE
TEMPERATURE RATING
DENSITY GPM/SQ. FT.
HOSE STREAM
FIRE PROTECTION GENERAL NOTES
ORDINARY HAZARD GROUP 1
A) GENERAL STORAGE AREAS, (STORAGE LESS
THAN 8' AND QUANTITY AND ARRANGEMENT NOT
EXCEEDING THE LIMITATIONS OF MISCELLANEOUS
STORAGE) B) RESTAURANT DINNING AND SERVICE
AREAS, C) MECHANICAL & ELECTRICAL ROOMS, D)
PASSENGER-HANDLING AREAS.
130 SQ. FT. PER SPRINKLER
ORDINARY 155°, QUICK RESPONSE
0.15 GPM OVER 1500 SQ. FT.
250 GPM / DURATION 60-90 MINUTES
??
AIRPORT AT SANFORD, FLORIDA
THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF EXISTING FIREPROOFING ON
THE EXISTING STRUCTURE AS REQUIRED FOR THE INSTALLATION OF NEW SUPPORTS FOR PIPING
INSTALLED UNDER THIS CONTRACT. THIS CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE
REPAIR OR RE-APPILACATION OF NEW FIREPROOFING AFTER ALTERATIONS TO THE EXISTING
BUILDING FIREPROOFING ARE COMPLETED PER PHASE.
THIS CONTRACTOR SHALL EMPLOY A STRUCTURAL ENGINEER TO PROVIDE ENGINEERED
DRAWING FOR THE SUPPORT OF THE NEW FIRE SPRINKLER MAINS AND BRANCH PIPING
NEEDED TO COMPLETE FIRE SPRINKLER COVERAGE OF THIS EXISTING METAL BUILDING
AS SHOWN ON SHEET 1-SA-FP101 AND ON 1-BC3-FP100.
500 West Fulton St.
Sanford, Fl. 32771
Ph: 407.322.6841
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Arch. Lic. No. AA2600926
Lndscp. Lic. No. LC0000298
CPH, Inc.Plans Prepared By :Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.
NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Surveyors
Traffic /
Transportation
Offices in:
Florida
Puerto Rico
Connecticut
Maryland
Texas
A Full Service
A & E Firm
C:\Users\dkramer\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_dkramer.rvt7/13/2017 1:25:04 PM1-G-FP001PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFIRE PROTECTION TABLES, SCHEDULES, ANDGENERAL NOTES07-14-2017S12014DAKDAKDAKDMAS NOTEDDAKDAKDAKDMAS NOTEDREVISIONS#DATEDESCRIPTIONBYCONFORMED SET
205
5
'
-
0
1
/4"5
'
-
0
1
/
4
"
5
'
-
0
1
/
4
"
5
'
-
0
1
/
4
"
5
'
-
0
1
/
4
"
5
'
-
0
1
/
4
"
BOS BOS BOS BOSBOSBOS
1-LD-FP100
1
1-ELD-FP100
1
1-BC3-FP100
1
1-NEE-FP100
1
1-BC3-FP101
1
1-SA-FP100
1
1-FIS-FP100
1
1-BH-FP100
1
1-NIE-FP100
1
1-BC3-FP102
1
500 West Fulton St.
Sanford, Fl. 32771
Ph: 407.322.6841
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Arch. Lic. No. AA2600926
Lndscp. Lic. No. LC0000298
CPH, Inc.Plans Prepared By :Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.
NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Surveyors
Traffic /
Transportation
Offices in:
Florida
Puerto Rico
Connecticut
Maryland
Texas
A Full Service
A & E Firm
1/64" = 1'-0"C:\Users\dkramer\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_dkramer.rvt7/13/2017 1:25:36 PM1-G-FP101PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE FIRST FLOOR PLAN - PHASE 1 - FIREPROTECTION07-14-2017S12014OUTBOUND
ADDITION
ORLANDO SANFORD INTERNATIONAL AIRPORT
KEY PLAN
SCREENING
EXPANSION
NEW LOADING
DOCK
BUILDING
EXISTING
LOADING
DOCK
OUTBOUND F.I.S. /
CUSTOMS
INBOUND
BLOCK
HOUSE
F.I.S.
SECURITY
EXIT
LOADING
DOCK
ELEVATOR
N
NORTH 1/64" = 1'-0"
COMPOSITE FIRST FLOOR PLAN - PHASE 1 - FIRE PROTECTION DAKDAKDAKDMAS NOTEDREVISIONS#DATEDESCRIPTIONBYCONFORMED SET
206
1-SA-FP101
1
1-NEE-FP100
2
1-NIE-FP100
2
500 West Fulton St.
Sanford, Fl. 32771
Ph: 407.322.6841
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Arch. Lic. No. AA2600926
Lndscp. Lic. No. LC0000298
CPH, Inc.Plans Prepared By :Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.
NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Surveyors
Traffic /
Transportation
Offices in:
Florida
Puerto Rico
Connecticut
Maryland
Texas
A Full Service
A & E Firm
1/64" = 1'-0"C:\Users\dkramer\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_dkramer.rvt7/13/2017 1:25:53 PM1-G-FP102PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDACOMPOSITE SECOND FLOOR PLAN - PHASE 1 -FIRE PROTECTION07-14-2017S12014ORLANDO SANFORD INTERNATIONAL AIRPORT
KEY PLAN
SCREENING
EXPANSION
OUTBOUND F.I.S. /
CUSTOMS
INBOUND
LOADING
DOCK
ELEVATOR
N
NORTH 1/64" = 1'-0"
COMPOSITE PLAN - 2ND FLOOR - PHASE 1 - FIRE PROTECTION DAKDAKDAKDMAS NOTEDREVISIONS#DATEDESCRIPTIONBYCONFORMED SET
207
TS
FIRE PROTECTION
1 1/4" MAIN DRAIN VALVE
EXTERIOR ALARM BELL
SUPPLY TO SPRINKLERS
GROUND LEVEL
6"MAIN CONTROL VALVE W/ TAMPER SWITCH
WIRED TO THE FIRE ALARM SYSTEM
FIRE DEPT. CONNECTION TO BE ON SYSTEM SIDE OF FIRE
BACKFLOW PREVENTOR-SEE CIVIL DRAWINGS FOR
LOCATION FDC THREADS SHALL BE COORD. WITH LOCAL
FIRE DEPT.
PIPE SLEEVE - CAULK AND SEAL
2" DRAIN PIPE - DRAIN TO EXTERIOR
U.L. LISTED ALARM WITH CHECK VALVE
U.L. LISTED VANE TYPE FLOW SWITCH
SPARE SPRINKLER HEAD BOX
MOUNTED TO WALL (5'-6" AFF)
NOTE:
1. LABEL PIPING IN ACCORDANCE WITH SPECIFICATIONS FOR SPRINKLER PIPING
THROUGHOUT BUILDING.
2. MAINTAIN FIRE RATINGS AT ALL WALLS AND FLOOR DECK PENETRATIONS AND REFER
TO ARCHITECTURAL DRAWINGS FOR WALL TYPES AND WALL RATINGS.
SEE NOTE BELOW
NOTE:
SEAL ALL PENETRATIONS THRU WALLS AND FLOORS WITH
FIRE CAULKING THAT IS UL LISTED AND MEETS OR EXCEEDS
THE UL RATING OF THE FLOOR OR WALL ASSEMBLY.
& NUT ASSMB.
CLAMP W./BOLT
RISER CLAMPPIPE
NOTE:
SPARE SPRINKLER HEAD QUANTITY SHALL BE
MOUNT IN A SECURE AREA
WHICH IS MAINTAINED BELOW
95°F AMBIENT
CABINET BOX SHALL BE 22 GA. SHEET METAL
WITH 19 GA. SHEET METAL COVER, PAINT
WITH RED ENAMEL INSIDE AND OUT, LABEL,
SPARE
SPRINKLER HEADS
SPRINKLER HEAD
WRENCH
IN ACCORDANCE WITH NFPA 13.3-11.
= 45°
VERTICAL THRUST BLOCK
VOL. OF CONCRETE (CY)
CONTRACTOR TO PROVIDE THRUST BLOCKS AT CHANGES OF DIRECTION.
BEARING AREA "A" (SF)
CONCRETE STRENGTH = 2,500 PSI IN 28 DAYS
TEST PRESSURE = 200 PSIG, SOIL BEARING PRESSURE = 2,000 LB/SF
SCHEDULE OF THRUST BLOCKS
10.0
3.02.04.04
NOTE:
8
6
12.0
8.0
6.0
3.0
8.0
4.0
TEE OR
DEAD END
PIPE
DIA.(IN)=
11-1/4°
=
22-1/2°
1.80.80.54.04.0
16.0
10.06.0
1.3
0.8
2.7
1.5
5.0
3.0
= 11-1/4°
==
90°45° = 22-1/2°
3.3
9.3
5.6
= 90°
SIGHT FLOW INDICATORREADILY ACCES-
TEST VALVE IN
SIBLE LOCATION
BRANCH LINE
INSPECTOR TEST STATION
DETAIL - WET SYSTEM
SCALE: NONE7'-0" MAX.FLOW EQUIVALENT TO ONE
RESISTANT OUTLET GIVING
SMOOTH BORE CORROSION
SPLASH BLOCK
SPRINKLER
WEATHER TIGHT
SLEEVE AND SEAL
45° ELBOW.
PITCH
PLAN (TYPE-1)PLAN (TYPE-2)WIDTHTRENCHA
A A
A
UNDISTURBED
EARTH (TYP.)
BEARING AREA "A"
BEARING AREA "A"
BEVEL 2:1
SECTION A-A
3"MIN.(TYP.)
TYPES 1, 2, AND 3
BOTTOM OF TRENCHH/26"MIN.H/2H24" MIN.THRUST BLOCK DETAIL
SCALE: NONE
MARKER PIPE
ARROW BANDING TAPE
3" & LARGER PIPE
1" TO 2 1/2" PIPE
3/4" & SMALLER
- 2 1/4"
- 1 1/8"
- 1/2"
FIRE RISER CLAMP
THROUGH FLOOR DETAIL
SCALE: NONE
SPARE SPRINKLER HEAD BOX DETAIL
SCALE: NONE
PIPE IDENTIFICATION DETAIL
SCALE: NONE
FIRE PROTECTION RISER DETAIL - WET PIPE
SCALE: NONE
500 West Fulton St.
Sanford, Fl. 32771
Ph: 407.322.6841
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Arch. Lic. No. AA2600926
Lndscp. Lic. No. LC0000298
CPH, Inc.Plans Prepared By :Drawn by:Designed by:Approved by:Checked by:Scale:Job No.:Date:File:Sheet No.
NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Surveyors
Traffic /
Transportation
Offices in:
Florida
Puerto Rico
Connecticut
Maryland
Texas
A Full Service
A & E Firm
C:\Users\dkramer\Documents\SANFORD AIRPORT TERMINAL EXPANSION 2017_dkramer.rvt7/13/2017 1:26:00 PM1-G-FP500PROJECT ALPHA ONE (TERMINAL EXPANSION)ORLANDO-SANFORD INTERNATIONAL AIRPORTSANFORD, FLORIDAFIRE PROTECTION DETAILS -107-14-2017S12014DAKDAKDAKDMAS NOTEDREVISIONS#DATEDESCRIPTIONBYCONFORMED SET
208
QUARTER TILE IS ACCEPTABLE
QUARTER TILE IS ACCEPTABLE
6"
6"
6"
Acceptable Locations for
6"
12"12"
Sprinkler in 2'x2' Ceiling Tile
Sprinkler in 4'x2' Ceiling Tile
12" 12" 12" 12"
12"
12"
Acceptable Locations for
UPRIGHT SPRINKLER HEAD DETAIL
SCALE: NONE
REDUCER
1" X 1/2"
DEFLECTOR
SPRINKLER
1"NPT FEMALE
COUPLING REDUCER
1" SYSTEM
DROP NIPPLE
CEILING
FINISHED
SPRINKLER CUP
ASSEMBLY
COVER PLATE
COVER PLATE
TYPICAL CONCEALED PENDENT
SPRINKLER HEAD DETAIL
SCALE: NONE
TYPICAL SEMI-RECESSED PENDENT
SPRINKLER HEAD DETAIL
SCALE: NONE
1" SYSTEM
DROP NIPPLE
FINISHED
CEILING
REDUCER
1" X 1/2"
SPRINKLER
GUARD
DEFLECTOR
1" X 1/2"
REDUCER
UPRIGHT SPRINKLER HEAD W/ GUARD DETAIL
SCALE: NONE
PIPE SUPPORT DETAIL
SCALE: NONE
ROD
3/8"