HomeMy WebLinkAbout915 E 1ST STREET 18-4597 Demo 2nd fl E, W, S elevationsCITY OF 4)SANFoIRD PERMIT APPLICATION BUILDING DIVISION I b _95q] Application No: 0 1 Documented Construction Value: $ GA 500 . oc Job Address: 915E 15 r ST. SAtJ F01%. rL. 32'11 Historic District: Yes ❑ No® Parcel ID: Residential ❑ Commercial Type of Work: New ❑ Addition ❑ Alteration ® Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: RxMOLE F415rinlC 21LRoar- Eg;�4 Lesr AND Saur/f Plan Review Contact Person: Title: no � L Phone: Fax: Email: Property Owner Information Name Armory Board, State of Florida Phone: 904-823-0200 Street: 82 Marine St. Resident of property?: City, State Zip: St. Augustine FL 32084 Contractor Information Name l._OIiEN C0ni5'rzuoT161-/ Phone: (407) 63Io1489 Street:—P.O. goy- 4-70819 Fax: Ni f A City, State Zip: U • MonIR.oe, FL. 3274= State License No.: CGC $f/52.'ifo50 Architect/Engineer Information Name: CPH Phone: 407-322-6841 Street: 500 West Fulton St. Fax: City, St, Zip: Sanford, FL 32771 E-mail: lmurrah@cphcorp.com Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. _512•t� 7.1 S l�� ��� O.a 1b, , FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date. 6'^ Edition (2017) Florida Building Code NOTI :In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Ownerl William Harei Print Owner/Agent'i'Name NUI •Daze ` & hellity Mgmt Officer RACHET 'iOMMERER MY COMM', +•')N X GG02�1,'410 EXPIRES .:�,stembar 07,t CNm a �ignatme of Contractor/Agent Date 1i p rc > O U Uzi,. L6-1 £ rW P' ntractorlAsent's Name m Z h W It�l3�l� Silat5oof Not • onda Date W Owner/Agent isx , ,„ saxatoqmte 14e of --\-d Contractor/Agent is _ Personally Known to Me or Produced ID Type of ID Produced ID X Type of ID uet ticenS& ' BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Gas ❑ Roof ❑ Construction Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑ No ❑ # of Heads APPROVALS: ZONING: COMMENTS: UTILITIES: Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: FIRE: BUILDING: /Z- r/ -1400 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: T hereby name and appoint: J F)Sonl G2,04115 an agent of: s-ra uCTiO nl (Name of Company) to be my lawful attomey-in-fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): 19 The specific permit and application for work located at: q15 E. ISTS-rzeE'r� Ssln/ForD7 RG. 32771 (Street Address) Expiration Date for This Limited Power of Attorney: 1 14 119 License Holder Name: DaN CoHkBIJ State License Number: 0 -6C -1-;f 15-2-46 SO Signature of License Holder: i STATE OF FLORIDA COUNTY OFDW Pa The foregoing instrument was; 200 , by ficin iel S�Er a to me or�&ho has produced identification and who did (did (Notary Seal) '1,Wy Jenayra Rivera Laureano NOTARY PUBLIC � STATE OF FLORIDA a Ca" GG057378 • E IS Expires 12/21/2020 (Rev. 08.12) before me thisI�Zday of &0 who is o personally known an foaUa Print or Fhe name Notary Public - State of �Ur. ck^- Commission No. 6,6, p -)?� My Commission Expires: j i I � .. .r. .j �l .:�"" i .. .til- .- .'���•�_ ' -• -> �. i �. i r� j� r 1 i I i i; i • i i i I i i ;i i Al Grant Malo Of The Circuit Court 8 Comptroller Seminole County FL SG% ,Clerk FEE$10.003 Book:9252 Page: 1925; (1 PAGES) RCD: 11/21 /2018 11:32:19 AM RE#2018 111 lI ENTP THIS INSTRUMENT PREPARE�EEDDDD BY: /+ Nemn: [�f{.yTRUCT70n) ci Addreec PO fAOX 08)x- LK Meat2e6FL. 297F7 - NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: Pamal 10 Number: The undersigned hereby gives rwtiee that improvement will be made to certain real property, and in accordance with Chapter 715, Florida Statutes, the follovdng information is pmMed in this Notice of Commencement. DESCRIPTION OF PROPERTY. (Legal description of the property and street address H available) Lots 1-8,11-36 and Block "K" of First St. Extension c i J I 151 GENERAL DESCRIPTION OF IMPROVEMENT: Remove awiSTfsJ6 W1fJD0015 om 7tIH ZfF*Lcctx EAST, W65T AND 'Sol,TH E1—e!VAT101AS - ERA4M9 PW1id, State of Florida ame Address; 82 Marine St St Auojstine F132084 Fee Simple Title Holder (H other than owner) Name: Address: r - s' . Oo "r l./e r -i r a w....�.�rr Persons within the State of Florida Designated by Owner upon whom notice or other doeuments may be served as provided by Section 713.13(1)(b), Florida Statutes. In addition to himself, Owner Designates To recelva a COPY of the Lienor's Notice as Provided In Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is i year from data of recording unless a different date Is specified) WARMNG TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS To YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING. CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of Bury, I declare that a read the foregoing and th Tft�&n R a_ re$fii�; I, to th e t ' y edg al ;hagef Wll.t t 0�t@r M, . , i �, William Harty Cpnstru"don & Facility Mgrs '.rMner4agnam,e .•eef 1 fi4i e�+" Fkritesmessna13(t)(a):'The oxn9 mVeltl nNa nollcsm mmmen�nW.MroOMelr§nreybe pemm6eetorteninNaarharrleen.- State of GlorzAs- Countyof J--- JOlut< '"�" The foregoing instrument was acknowledged before me this 14- day of AWe-heK.2,(- by th11t -- {� dlt/lC Who is personally known to me Name dpersm mW4g cal OR who has produced identification ❑ type of Identification produced: MY COMMISSION N GG0214f0 ,���� ���JJ 3 e: � , Y EXPJREB September 07, 2020 addal ; 9i -+n rdt,{JG�✓ Notary al9naWre ,; ,; ., i : i i '; i i { f. �: i 'i �: i ,, ', j !' .ffr 7 �' '1. .1 Customer Name: Address: Phone: Fax: Customer Information: ;4,4 # Owls Dale: 11Pt w Mt Projact Name: Sanford Armory Quota Name: PERMIT Comments: Quota Number. 1919374 Order Daft: PO Number. "FFI� RO size for Flange le for standard Rx buck With ora Act till Please contact Your suppNer for other Flange oDaflinn ITEM ✓L SIZES LOCATION f TAG PRODUCT DESCRIPTION UNIT PRICE / EXTENDED PRICE un iu m, 100.1 None Assigned Quantity: 23 RO91w 47X85.5 UMt BW: 40.25 X84.5' "'PRODUCT"' Row 1 3540 Single Hung - Vent - 1 Unns - 40.25W x 84.5H DIMENSIONS «' 40.26W x 84.51-1 FRAME — East, VW. 5, Framp Type • Flange, Exterior Color - White "' GLASS "' - . Glazing TyR6 - Insulated, arses nm - Clear, HP Low -E, Gieea Screen - Half, Saw Mesh Type - Charcoal Fiber, Scream Packed Separa" - Yee "' NERC '•• Series 36ft:SingleHung, U-Fectoml).33, SHGC::0.23, Vr::0.44 " Performance "' Sarles 3540::SitglaHung, Calmdated Positive DP Rating::30.08, Calculated N%dve DP RaWg::30.011, DP RLde ID.,:3540 SH, Ratkg Typi :DeellmPressure, Structure) Ralrv.IJC-PG35, Water Ratlrg::6A3, FL lOvI787e, STC Raung27 3540 Sarnia Hutto - Vent - customcustom ITEM a SIZES LOCATION I TAG PRODUCT DESCRIPTION Urn atm: 200-1 None Assigned Quentay: 1 RO 81m: 42'X85.6* Una SRs: 4025 X 84.6" "'PRODUCT"' Row 13640 Skple Hung -Vent -1 Unite -40.26W x S4.5H "' DIMENSIONS 40.25W x SCSH ••• FRAME "' east, Vinyl, 5, Frame Type - Flange, Exterior Color- While "' GLASS "' Gloang Type- Insulated, Glare Tint -Clear, HP Low -E and Obscure, ODaaea Plaosmem - Full, Glow Strength - DSa "'SCREEN "' Screen -141K Screen Mesh Type - Charcoal Ftifor, Suxeans Packed SeperNely"Yea NRtO Sorbs 3540 ZIngleHurg, U-Faolor,0.33, 8HGC:,sM= Vr,,M44 . Performarm w Soda 3540:SIrWWung, Calculated PaiSva DP Rm*VL,30JA Calculated Negative DP Ratinp,30.0e, OP Rula IO.:3tH0 SH, Rating Typa:DMlpnPw WWS. 61rumRW RasriliAr-P080'. Wier PA&W..A^ R. I3x1767t, STC RaWtg27 (�41�Kut5s5 0 UNIT PRICE / EXTENDED PRICE 0" -e7eM'.aOd-3l:•dAW ALqft'HS OOW,:OI QMH d0'£t '£t•09::&MWd dO &NWDd P »-a.IA'Ez•o.:�Hs'Eao:�Od-n r-wO got" Md. sw" dN.,. pa*+ed ewebS'+o9li leowsVO-odi(L V>seW ueaes'ON .ueea5 I�V�/ 66e9G-MMJd'zWa..'wroH ... N239W... �1sAh'09°Jd-Ol::0e0B21 P�^46'�ns�dO&�0::�1 950 • tHOL"s L 810 '9-MO'1 dH 'reePJ . mi svI°J'PWeineul • ek a+Rgn ... a0UwUIJ Od ... WO::lA'YL•O::ODHS ' G 'O="PRd•n IOSIOW::C6S£ OWsS sevis � OWN ». AWE -94&049ese0'SOJ- uOPROGI ®11UM' �IQD+W+eiK3'aBuBld - ed(l gumd'"'WO3 Pepdwel'3•Al dH'NOGO -toll Sel`J "WOU) - NMI 04MO .99M. ...3VNUi... sg4M-jaroo+oP@n roaueli-eatieum3'MwA 1003 .E4x.s EL :"e nun Heg NM9'9z ...3vmad... HMxMg'OY .VSX.4S'oc :weoy .. SNOISN36tl0.« z ;Awme H9'WXAA9S'OY-qun Pe:9d-NZWIMQMWMe&Mwd POUB!NV GUON HES X Ms'BL - Wwn C - WOA - SMH efOu!S 065E G MOH «.lon0oad «. z *mom ...1O(M0Nd.« POuDPRVauON 6.504 mmwwn orad 03(Wp 1fl I30nld 11Nn NOLLWHOS301On00Nd OVI J NOUVOM Mw T w31Y es eum Md O m .:OI Wra-vne OS SRI d0 1 Pe7ei�:+18'J 'Et'D9:AOR d0 d nopOSPe-00::065£swAS 8 9Y'a:lA'YZ'O=OOH8'l ' .. a}n eS��10:-0656' SaWS w ,Awj dH'�eWO-sMRl �W ��?4Sp��O ry..�SSdI'J ... ORM • WO MPW3' i - 0"1 "w.4 JAA yse3 ... MY&I .. AS X.96 :849 wn HOSxAW .t 1w M"GV .» SNOISN'M « H09 x MOO - SIM G - PDXbJ - NOMM �Id 049E t MOH ...lOrMW... PeUBMVOWN t-OoY =HBe tid OIGXaM / 33fad 11Nn NOI1divoS301anOoad 9V1 / NOIIVOO'7 S3= @ 66e9G-MMJd'zWa..'wroH �1sAh'09°Jd-Ol::0e0B21 P�^46'�ns�dO&�0::�1 .. �Pel1 Md 009£--01 W H dO '£t-09::0uPeH do sApOeN PelelnORo 'EG-09::Bupu d0 eNBod Pmvino * lespaw:om sapaS ... a0UwUIJ Od ... WO::lA'YL•O::ODHS ' G 'O="PRd•n IOSIOW::C6S£ OWsS OWN ». AWE -94&049ese0'SOJ- uOPROGI Pepdwel'3•Al dH'NOGO -toll Sel`J "WOU) - NMI 04MO .99M. sg4M-jaroo+oP@n roaueli-eatieum3'MwA 1003 .s69x .4soY :.AstIW1 ...3vmad... HMxMg'OY .99SX20 :wsoa SNOISN3"10... z ;Awme H9'WXAA9S'OY-qun Pe:9d-NZWIMQMWMe&Mwd POUB!NV GUON G-00£ :uim sun «.lon0oad «. M QWN3"3 / 301W LIM NOLL&H0001D1QO)id DWI l WUVO01 sus T au3 'TPN S SM LOCATION 1 TAG PRODUCT DEWapT►ON UNIT PRICE I EXTENDED PRICE Line Item: GOD -1 None Assigned '•" PRODUCT « Quantity: 1 Row i 3540 Single Hung - Vent -1 Unita -40.26W x 52.5H DIMENSIONS•"" RO Slim: 42" X 53.5' 40.2M x 52.51-1 Unit site: 40.25"X 52.6" `"� FRAW "' EaA Vinyl, Frame Type - Flange, Extariar Color. While GLASS •« GlarngiType- insulated, Glass Tint - Clear, HP Low -E, Glass Strength - DSS ""'SCREENSam - Half, Screen Mesh Type - Charcoal Fliter, Screens Packed Separately - Yea NFRC'"erSed 3640::SingleHung, U-Fador.:033, SHGC::D.23. Vrc0.44 "••Periormance ••" ILE Series 3540nSingleHung, Calculated POW" DP Reling., 35.3, CeaMeed Negative DP Rstlng::47.2, DP Rule 1D -35W SH, Rating TYpe:DmignPreswre, SVWursl Ra5ng::LC-PG35', Water ,.,....... 0.15 _._. Reting::5.43, FL ID::17676, STC Rafing::27 .jjjD 51nole Hung - Vent - CustomCu«om 110 APPROVED D NOTN'PROVED - RESUBMT 1 I Submitted By: J A --,0 ,j GF -AN N is slghad,rs: Date: Accepted BY: Signature: Date: Product i end ratings in our Paradigm quoting tool ere as accurate as possibie from the latest release. We store to 101 cY between our quoting tool and order acknowledgements. However, the acknowledgment is the FINAL RATING l products. Customers are responsible for verifying ratings on their acknowledgment DMFerancss should be imni Y d to paradigmsupportemnvd.com. All ratings are for individual windows and doors only. For mtormalion regarding muffed or Stacked units, please contact your sales repmeentative. d41 -- I el I ' �. L. •�,j S. N�.!'i.cnV L`�''�:'o�, �,�? LCL"(.! y. V) City of Sanford Building and Fire Prevention Product Approval Specification Form Permit # Project Location Address q IS E 1 ST ST SANFoaDO FL. 32-74'7 As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuildina.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category/Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hun MZ I.;INGLe 14uw WINDOW l 1-7(&-7(o— R-7 Horizontal Slider Casement Double Hun Fixed M -ru#-F- WINDOW FL I$co44- R?- 2Awnin Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name on LLn (Please Print) June 2014 EXTERIOR ELEVATIONS NoC" OF SANFORD Ord-!; Rg NATIONAL GUARD ARMORY 0 "n mn 0 m .� i�, Professional •la t SCIS Home Log In i User Registration ' Hot Topics i Submit Sumharge i Stats a Faas t Publications Coni Us SCIS site Map Links i Sea¢h � w �r 'a Product Approval db USER: vutBe user Product Aoomvai Menu> Product or Application Search > Application List > Application betail FL * FL18644-R2 Application Type Revision Code Version 2017 Application Status Approved -Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 (717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich, PE '�: Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S. 2/A440 2005 AAMA/WDMA/CSA 101/I.S. 2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 12/31/2017 Date Validated 12/31/2017 Date Pending FBC Approval Date Approved 01/04/2018 Summary of Products r FL # Model, Number or Name Description 18644.1 3500 PW 81x63 Fin Frame Limits of Use Certification Agency Certificate Approved for use In HVHZ: No PW B910 81x63.odf Approved for use outside HVHZ: Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +50/-50 04/30/2021 Other: FW -1-050 Installation Instructions FL18644 R2 II 08-02818.odf Verified By: Luis R. Lomas PE -62514 Created by Independent Third Party: Yes Evaluation Reports FLIB644 R2 AE 513610.odf Created by Independent Third Party: Yes 18644.2 3500 PW 81x63 Finless Frame Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL18644 R2 C CAC APC Q17110.01-109-47-110 3500 FXD (1118221 odf Approved for use outside HVHZ: Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +35/-35 11/18/2022 Other: LC-PG35 Installation Instructions FL18644 R2 11 06-02818.odf Verified By: Luis R. Lomas PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL18644 R2 AE 513610.odf Created by Independent Third Party: Yes 18644.3 3500 PW 60x96 Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL R2 C CAC APC - F1910 Ol odf Quality Assurance Contract Expiration Date Impact Resistant: No Design Pressure: +50/-50 10/08/2020 Installation Instructions Other: LC-PG50 El 18644 R2 lI 08-02858 odf Verified By: Luis R. Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL18644 R2 AE 513666 F1910 2858.pd Created by Independent Third Party: Yes 18644.4 3500 PW 96x60 Limits of Use Approved for use in HVHZ: No Certification Agency Certificate FL18644 R2 r' CAC MI Windows - 3500 PW B9102 96x60.odf Quality Assurance Contract Expiration Date 04/30/2021 Installation Instructions Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-60 _ Other: LC-PG50 Negative DP= -60 F118644 R2 II 08-02859d& Verified By: Luis R Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL18644 R2 AE 513667 odf Created by Independent Third Party: Yes Beck Nevi Conte Us :: 2601 Blair Stone Road Talla ,51, FL 32399 Phone 850-487-1624 me State of Florida Is an WEED employer. Coovnoht 2007-2813 State of Florida.:: pnvacv Statement :: Accessibility Statement :: Refund statement Under Florida law, email addresses are public records. If you de not want your a -mail address released! In response to a public -records request, de not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487 . 1395. •Pursuant up Section 455.275(1), Florida Statutes, enertive October 1, 2012, licensees licensed under Chapter 455, F. S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To detemllne if you are a licensee under Chapter 455, F.S., please dick here . Fired.. Approval Accepts: ® W ® En Credit Card Safe 1, BCIS Home t Lop In User Registration Hot Topia Submit 5uncharge i Stats 6 Facts Publicurions j Contact Us BOS Site Mai, It Links Search Halo Product Approval USER: Public User r 90 " �' � , - "; P Product Approval Menu > Product or Art Search > Application Le > /Application DeNil FL * FL17676-R7 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 (717)365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Unch, PE C ' Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2011 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 08/08/2018 Date Validated 08/08/7018 Date Pending FBC Approval Date Approved 08/09/2018 aizin92 woc (�-i)oc4I . o e4--- Summary of Products FL # Model, Number or Name Description 17676.1 3540 SH 36x74 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC(11355)C7327.01-109-47 - 1.Ddf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 04/12/2022 Design Pressure: +35/-50 Installation Instructions Other: LC-PG35. Units must be glazed in accordance with FL17676 R7 II Install - 3540 SH 36 x74 Fin.odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.2 3540 SH 36x84 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC 3540 Fin 36x84.gdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/27/2020 Design Pressure: +40/-50 Installation Instructions Other: LC-PG40. Units must be glazed In accordance with FL17676 R7 II Install - 3540 SH Fin 36x84.odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.3 3540 SH 40x66 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC A3485.01.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/26/2019 Design Pressure: +35/-45 Installation Instructions Other: R-PG35. Units must be glazed in accordance with FL17676 R7 II Install - 3540 SH Fin 40x66.odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.4 3540 SH 44x63 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC 3540 Fin 44x63.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/26/2020 Design Pressure: +40/-47 Installation Instructions Other: R-PG40. Units must be glazed in accordance with FL17676 R7 II Install - 3540 SH Fin 44x63.12df ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.5 3540 SH 44x72 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC 3540 Fin 44x72.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/01/2022 Design Pressure: +35/-47 Installation Instructions Other: R-PG35. Units must be glazed in accordance with FL17676 R7 II Install - 3540 SH Fin 44x72.12df ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.6 3540 SH 44x84 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC(10816)C7324.01-109-47 - 6.odf Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: No 04/12/2022 Design Pressure: +30/-30 Installation Instructions Other: LC-PG30. Units must be glazed in accordance with ASTM E1300-04. FL17676 R7 II Install - 3540 SH Fin 44x84.12df Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.7 13540 SH 52x84 Fin Frame Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL17676 R7 C CAC APC 3540 Fin 52x84.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/26/2020 Design Pressure: +25/-25 Installation Instructions Other: R-PG25. Units must be glazed in accordance with FL17676 R7 II FL17676 111 II Install - 3540 SH Fin ASTM E1300-04. 52x84.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.8 13540 SH 36x74 Finless Frame Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL17676 R7 C CAC APC 3540 FLS 36x74.12df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/28/2022 Design Pressure: +35/-50 Installation Instructions Other: LC-PG35 FL17676 R7 II 08-01252B 7.ndf Verified By: Luis R. Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 5118546 1252.pdf Created by Independent Third Party: Yes 17676.9 3540 SH 36x84 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC 3540 FLS 36x84.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/27/2020 Design Pressure: +40/-50 Installation Instructions Other: LC-PG40 FL17676 R7 II 08-01372 511989.12df Verified By: Luis R. Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 511989 3540 FLS 36x84.12df Created by Independent Third Party: Yes 17676.10 3540 SH 44x72 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17676 R7 C CAC APC 3540 FLS 44x72.odf Quality Assurance Contract Expiration Date Impact Resistant: No 08/28/2022 Design Pressure: +35/-47 Installation Instructions Other: LC-PG35 FL17676 R7 II 08-012476 10.odf Verified By: Luis R. Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 511849B 1247.12d Created by Independent Third Party: Yes 17676.11 3540 SH 48x96 Finless Frame Limits of Use Certification Agency Certificate Approved for use In HVHZ: No Approved for use outside HVHZ: Yes FL17676 R7 C CAC APC 3540 FLS 48x96.odf Quality Assurance Contract Expiration Date Impact Resistant: No 08/28/2022 Design Pressure: +30/-30 Other: LC-PG30 Installation Instructions FL17676 R7 II 08-01371E 11.12df Verified By: Luis R Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 511988B 1371.pdf Created by Independent Third Party: Yes 17676.12 3540 SH 52x62 Finless Frame Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL17676 R7 C CAC APC 3540 FLS 52x62.12df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/27/2022 Design Pressure: +35/-35 Installation Instructions Other: R-PG35 FL17676 R7 II 08-02269A 12.odf Verified By: Luis R. Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 513015A 2269.odf Created by Independent Third Party: Yes 117676.13 13540 SH 152x72 Finless Frame I Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL17676 R7 C CAC APC(10818)C7325.01-109-47 - 13.12df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/12/2022 Design Pressure: +30/-30 Installation Instructions Other: R-PG30 FL17676 R7 II 08-02270A 13.pdf Verified By: Luis R Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 513016A 2270.odf Created by Independent Third Party: Yes 117676.14 13540 SH 152x84 Finless Frame I Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: R-PG25 Certification Agency Certificate FL17676 R7 C CAC APC 3540 FLS 52x84.pdf Quality Assurance Contract Expiration Date 05/26/2020 Installation instructions FL17676 R7 II 08-01514 512141.gdf Verified By: Luis R Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 512141 3540 FIs 52x84.1df Created by Independent Third Party: Yes 117676-15 13540 SH 148x72 Fin Frame I Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: R-PG35. Units must be glazed in accordance with ASTM E1300-04. Certification Agency Certificate FL17676 R7 C CAC APC A2726.01.12_df Quality Assurance Contract Expiration Date 07/20/2019 Installation Instructions FL17676 R7 II Install Instructs - 3540 SH FIN 48x72 (As Tested).odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 117676.16 13540 Triple SH I 108x74 Fin Frame Triple CHS Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-50 Other: LC-PG35. Units must be glazed in accordance with ASTM E1300-04. Certification Agency Certificate FL17676 R7 C CAC APC(10817)C7327.01-109-47 - 16.12df Quality Assurance Contract Expiration Date 04/12/2022 Installation Instructions FL17676 R7 II Install - 3540 SH CHS Fin 108x74.odf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.17 3540 Triple Single Hung 10802 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC 1359.06.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/05/2021 Design Pressure: +35/-45 Installation Instructions Other: R-PG35 FL17676 R7 II 08-03218A 171A.pdf Verified By: Luis R. Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 514171A.pdf Created by Independent Third Party: Yes 17676.18 3540 Twin Single Hung 73x71 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R7 C CAC APC F1902.01-109-47-RO 3540 SH.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 11/03/2020 Design Pressure: +35/-40 installation Instructions Other: R-PG35 FL17676 R7 II 08-02997A.{Zdf Verified By: Luis R. Lomas, PE PE -62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R7 AE 513853A.pdf Created by Independent Third Party: Yes Baek Noxt Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic Cohen Construction, Inc. P.O. Box 470819 Lake Monroe, FL 32747 ATTN: Daniel Cohen Dear Mr. Cohen: STATE OF FLORIDA Department of Military Affairs a of ft Ablatant feutral St. Francis Barracks; P.O. Box 1008 St. Augustine, Florida 32085-1008 October 3, 2018 RE: Project Number 218022 NGA Window Replacement Sanford, Florida NOTICE TO SECURE PERMITS/PRE-CONSTRUCTION MEETING NOTICE This letter serves as your official notice to secure ,permits for the project referenced above. Permits are to be applied for from the appropriate city/county office within ten days of receipt of this letter. Please apply for the stamped set of plans and specifications from the Architect/Engineer if you have not already done so. These documents are required to obtain necessary permits and must remain at the project site, for the duration of construction. If permits are not received before the Pre -Construction meeting date, proof of application must be supplied at the meeting to the project manager. The Notice to Proceed with mobilization and construction will be issued upon your notification to the Construction & Facility Management Office's Project Manager, that all required permits have been issued and received. The Contractor shall, within ten calendar days from date of this Notice submit to the Project Manager for review and approval three copies of a Schedule of Contract Values which will reflect the estimated cost of each subdivision of work for each specification section, further detailed by subcontractor items, and utilizing the Construction Specification's Institute "Master Format Broad Scope Section Numbers." The value of each item shall include a true proportionate amount of the Contractor's overhead and profit. The sum of all such scheduled values shall equal the Contract Sum as evidenced by the Agreement. -2- A Pre -Construction meeting for this project If you have any questions please contact Kenn not been scheduled at this time. Woodruff at (904) 823-0272. ectfully, - 2 Co0y B. Kennedy Major, Florida Army National Guard Busness Manager Contract Management Branch • A statektt babrrate Owner std CoMrscbor rratde trio + ► of_ �TEm �„ ate yew Two T houta wl . Number a4a Number 2atlQ1 Peaject Locatim: NOW. WGA VYfftdow ): ob FUWDMG: AON AND SETWEEN: Tho DepartriM d MUmy Atift (DLK 2M WAft Road 207. St. AuWA*W. Ft. 3t3. haskoft called the OWNER. sed .1 pl , r Nam Cohen Cortttr lCft►, trtic. 4074MIM Eind: orcalled the CONTPACTOR. The owner and Co t rn clor apros as tet lx�thebw: 1. nM CONTRACT DOCtiMENTS -7M Co ftd Doc" is ao i tt offt Aprebat" ft Caebr dw% feoporai. wndtdorks ffie Canko d Sehpplerhtesttsry Bald aper cconcamm). ft- acdicaliorat. Drafto. an Add 1— bows! PW to OZKA on d the A0100fr stt. tfhe Non-TeclttiCol for as te4 sad all ModMomflow b t#te above, Wooed 7hQ+ss>io M tfhe Coapt. atd all ere "W a parts the as S attached to Vft AWs merht or repeated heroin. An anurnenstlon of thi fir. 11—A ittOti. and atfdeatb b as tallows: as attd DrrMkw prateered Her• CPN. Ur. gOD West Ftdlon 8b+eet Sthdord. FL tdtrtds: rhla be aMeM aaanlbnt tot tote peo�etta rhltid t)artttraot Doks+rYtawttrr. shepr+avttior�s at*tttar basbA{treamerttwttidt h�ea pr7roadte tt,tte � of a tset: ethati ooeb+d otrer the �1�. ate'Genetal G'atrorts and Sw�htay Cerwrai C�octdidarta; era tehtf Sptsmataenr General x tt�w ra ooi* d ser the ewwal MM -c koer dead rm FaA2a1 of All 4 Iran merle aArctaef. ILE t THE WM- Tote Conhsdw shd pedt-n al work required byte Uptaet DOMWN me fwb= as tpatllN b the Scope4f Work. No Ion a the alptht'Map shell be 60000d toe the POP" WrtU to urf" by the DNAs CLEC !. CONTRACT St3## - The Owner " MYftCon"Cl r ibr the perbktt� *alta work, tuttjed tD aMllons and *Kkxtlorah bychow how asPwAdedin the Cortr:lliow of ft Corhbse t. In Cwfe tt "Whk the . kat Stan: Siert-Fow Tftmmd Ft a lturlr M a ted =IfJO Dors In C4A*Mt LE & Ft MING - rw Stab a Fbridatt p®rt'txrnanue anti d tidWw b Payr uPdw dtb cor*W is oa*Wd upon MM*6ftdh 11 tend sn appropriaw bythe Soft Lqkbave. WITt1FSS MMM -OF, the paIies hen to nava eoeoaded tries fteetned trio tt►egr, and Ww tt d wrkten 000 CONTRACTOR OAR ,TE r DWUar Apwd by FALLQNAMN.SC. ".1067691101 + D=tc 2018.04.21 16:45:28 -04W AS WM moi: DM=&w2117Ak"4%vw SEP13 VMASYLVtAAUCWI$34945245 ��... APPR TO f Oaks see a� c INSPECTION SEQUENCE BP# 1&4597 ADDRESS: 915 East I" Street BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In 10 Frame Insulation Rough Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'l) Building Ceiling Grid Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — 1000 Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) REVISED: June 2014 ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final PLUMBING PERNIIT Min Max Inspection Description Rough Plumb Plumbing Underground Plumbing 2nd Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final MECHANICAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final