HomeMy WebLinkAbout308 W Lake Mary Blvd 17-2943JUN id1� CITY OF �01g Building & Tr�Ptievention Division ORD,o7 PERMIT APPLICATION FIRE DEPARTMENT Application o: 17-3413 Documented Construction Value: $ Job Address: 308 W. Lake Mary Blvd, Suite 301 Historic District: Yes❑No❑✓ Parcel ID: 11-20-30-523-0000-0010 ResidentialE] Commercial ✓ Type of Work: New[] Addition❑ Alteration✓ Repair ❑ Demo ❑ Change of Use❑ Move Description of Work: add/relocate sprinkler heads as per tenant build -out Plan Review Contact Person: Liz Johnson Title: Phone: 407-468-3338 Fax: 386-259-4057 Email: admin@aceautomaticfiresprinkler.com Property Owner Information Name Boulevard Plaza LLC Street: 3200 N. Military Trail, Suite 400 City, State zip: Boca Raton, FL 33431 Phone: Resident of property?: No Contractor Information Name Ace Automatic Fire Sprinkler Phone: 407-468-3338 Street: 1730 Trinidad Ave Fax: 386-259-4057 City, State zip: Deltona, FL 32725 State License No.: 11373300012003 Architect/Engineer Information Name: Lizardo Architects, Inc. Phone: 407-331-7781 Street: 101 Concord Drive City, St, zip: Casselberry FL 32707 Bonding Company: Address: Fax: Email: lizardoinc@gmail.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 61 Edition (2017) Florida Building Code IRevised: January 1, 2018 Permit Application A 0 N Vicinity Map & Site Plan NTS GENERAL NOTES 1, Piping to be 1* black schedule 4a threaded U NO. 2, Fittings to be l' black threaded cast Iron UNO. 3. Hangers coni ist of 3/8' TBC, w/ 3/8" ATR & I - swivel ring. 4. Denotes existing sprinkler piping. 51 Denotes new sprinkler piping. 6. Denotes existing QR 5,6k pendent sprinkler heads 7. Denotes New QR 5.6k pendent sprinkler heads 8. Denotes New QR 5.6k 155' Dry pendent sprinkler. 9. Denotes New QR 5.6k 200* Dry pendent sprinkler. 10, Hangers required on arm -overs over 1 foot in length. 11 Ceiling is ACT @ 12'-0' AFF ill Installation to he in accordance with NFPA 13 2013 edition. 12. Sprinkler renovations will not affect existing system 13. Project considered to be Ordinary Hazard It. Existing system design is Ordinary Hazard [I. TOP WHIM CLAMP (ULL LISIM OR F.M. APPROVED) OD ALL THREAD P HANGER DETAIL NTS SANFORD FIRE DEPARTMENT THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. AN ISSUED PERMIT SHALL BE DEEMED PERMISSION TO PROCEED WITH WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THESE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE FIREI PREVENTION. DIVISION FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS ON THE PLANS, CONSTRUCTION OR OTHER VIOLATIONS OF THE CODE. i. REVIE ED BY. MATT Mi I N N ETTO Plans Riecleivedll It lw llf Ju Tole SANK RD FIRE 9EPT By Fire Dept. DATE: .-FIRE SPRINKLER REN SCALE: 1/411 = 11-011 TION P N - - Davis & Cleaton Engineering, Inc. 260 Wekiva Springs Road, Suite 1060 Longwood, FL 32750 Ph: 407-539-2353 Fax- 407-539-2334 FRANK A. CLEATON, J& P.E. License # 35816 4_0 0 Z-0 co co C\I LL CU = - LL _3 :3 72, >% C 0 C.) C: 00 CU CD C) LL Ce) ........... 0� I 0 Lo X >N a . I N CO) 10 Lf) LL 0 CO) V) 0 i 4- : C D < CL r 00 ON (1) ca 0 C')r% %0 -6 0 Go 41 E az ME, Co co 42 > ME FIRE SPRINKLER PIPING PLAN coNnum # 18042 DRAWNBY LJ CHECrM BY 1313 6ATE 6/26/18 TOTAL AIS 95 2�%l SCAIX 1/4" = 1' -OF 2 Z-0 (D LO Lo LO U) 0 C, 14 :2 LO Ae CL CL (D (D U3 (D 0. a. LO (D L6 C3 3: Z Z Z a C) ()0 M 04 41 E az ME, Co co 42 > ME FIRE SPRINKLER PIPING PLAN coNnum # 18042 DRAWNBY LJ CHECrM BY 1313 6ATE 6/26/18 TOTAL AIS 95 2�%l SCAIX 1/4" = 1' -OF 2 J _1/5771� FIRE SPRINKLER RENOVATION PLAN SCALE: 1/4" = V-011 r r >^ Lo o Q1 p eh ao n O •� J Ni 1:i L M C a m v a Q. F 0 V 0 � V CO ®co) Q 1%%0 MM .� r 1e) m CU N .� YN (VS M J LL i -2 LL J :3 U � U) O C: r. O ocB U) LL M r r r >^ Lo o Q1 p eh ao n O — •� J Ni 1:i L M C a m v a Q. F 0 V 0 � V CO ®co) Q 1%%0 r r I r � r r w r i U r. O r r t _y A01 k r F r r I r � r r r i r r t r i r h � r - r a i _ r r � � J r r r r r r r , r r r _ r r r r r r r ♦ T r r .. r r c E r (D 0- 00 dO r AN � (O r O FIRE SPRINKLER PIPING PLAN CON7RAcr # 18042 DRAWNBY W CHECKEDBY BB Davis 8c Cleaton Engineering, Inc. DATE 6/26/18 60 Wekiva Springs Road, Suite 1060 TOTAL 95 Longwood, FL 3275{ ` � AIS Ph+:407-539-2353 Fax: 407-539-2334 � 2 SCALE 1/4" = 1'-0" FSK A. CYTON, JR. P.E. License # 35816 2 _ OF 2 Revision City of Sanford Respon a Comments ❑ SEP 2 7 2016 Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov _Permit # '� Submittal_Date Project Address:yl.� Contact:e4,c-3 �— l Ph: 321 22 --ch ''(D Email: b 2A r %A -)c-- n Trades encompassed in revision: ❑ Building ❑ Plumbing ❑ Electrical Mechanical ❑ Life Safety ❑ Waste Water General description of revision: Aw LAA 5Aigown '��.-, ROUTING INFORMATION Department Approvals ❑ Utilities ❑ Waste Water ❑ Planning ❑ Engineering ❑ Fire Prevention building z U w U of Q 0 0 Q N J U .T a 0 U 9/25/18 E 1 SEfi r4RATE TENANT I=>b I\ A 'T n7 /tr Sol =I n%v--� i C/ Ak I I **-- * PROVIDE FIRE EXTINGUISHER(S) HAVING A MINIMUM RATING OF 2—A. 10—B.0 FOR EVERY 3,000 SQ. FT.; EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED AND READILY ACCESSIBLE. THE TOP OF THE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR AND THE BOTTOM OF EXTINGUISHER SHALL NOT BE LESS THAN 4 INCHES FROM THE FLOOR. TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. PROVIDE TACTILE EXIT SIGNAGE PER NFPA 101.7 10.13 BASEBOARDS TO PROTECT THE EDGES. ALL GROUT TO BE SEALED. TOP OF BASE TO WALL MUST BE CAULKED. ALL EXIT DOORS SHALL HAVE THE TYP. OF LOCK THAT CAN BE OPENED FROM THE INTERIOR AT ALI. TIMES, WITH OUT KEY, TYP. FIRE EXTINGUISHERS TO BE PROVIDED AS REQUIRED BY LOCAL AUTHORITIES (MIN. ONE NEAR EXITS), AT 4'-0' A.F.F. TERMITE PROTECTION. PROVIDE TERMITE PROTECTION AT ALL PLUMBING TRENCHING AND ALL PLACES OF SLAB BRACKAGE DURING CONSTRUCTION. BEARING PARTITIONS: EXISTING BEARING PARTITIONS TO MAINTAIN EXISTING INTEPRITY, NO CHANGES. FINISH SCHEDULE COORDINATE W/ OWNER ALL FINISHES, PUBLIC STORE FLOORING CERAMIC TILE PUBLIC STORE CEILING ACOUST I CAL CEILING PUBLIC STORE WALLS: PAINTED GYP. BD. OR BLOCK RESTROOMS FLOORING CERAMIC TILE RESTROOMS CEILING ACOUST I CAL CEILING RESTROOM WALLS: PAINTED CWP. BD. ABOVE, FRP BELOW RESTROOMS TO HAVE MOISTURE RESISTANT FINISH AT FIXTURE WALLS. WORK AREA FLOORING SEALED GONG. FLOOR** WORK AREA CEILING WASHABLE ACOUSTICAL CEILING WORK AREA WALLS: FRP COOLER FLOORING QUARRY TILE*** LEGEND - - - - - --- ----- - ----- _— DENOTES EXISTING OR "BASE—BUILDING" PARTITION TO BE REMOVED,. VERIFY CONDITION IN FIELD. DENOTES EXISTING OR "BASE—BUILDING" PARTITION TO REMAIN. VERIFY CONDITION IN FIELD. DENOTES EXISTING ASSUMED ONE (1) HOUR FIRE RATED WALL ASSEMBLY. GENERAL CONTRACTOR TO FIELD VERIFY AND TAKE CORRECTIVE ACTION AS REQUIRED. 3 DENOTES NEW NON—FIRE RATED DRYWALL PARTITION: A— 3 5/8" MET. STUDS AT 24" O.C. WITH ONE (1) LAYER 1/2- MIN. THICK GYPSUM BOARD EACH SIDE: FROM FLOOR SLAB TO CEILING., OR AS NOTED DENOTES NEW COOLER OR FREEZER PARTITION: DOOR AND HARDWARE DESIGNATION SYMBOL: DENOTES DOOR NUMBER DESIGNATION DENOTES HARDWARE TYPE. DENOTES DOOR TYPE DOOR WITHOUT SYMBOLS ARE EXISTING TO REMAIN. REFER TO DOOR SCHEDULE SHEET A-5. OPENINIG IN EXISTING CONC. BLK. WALL PROVISIONS FOR NEW OPENING IN EXISTING CONCRETE BLOCK WALL ELEVATION SECTION 1. CONTRACTOR TO BE RESPONSIBLE FOR SECURING & SHORING OF EXISTING WALL CONSTRUCTION AS REQUIRED TO MAINTAIN STRUCTURAL INTEGRITY OF EXISTING CONSTRUCTION. 2. SAW CUT POCKET FOR NEW PRE—FABRICATED CONCRETE LINTEL, & SAW CUT EXISTING MASONARY FROM INSIDE OF THE BUILDING. 3. SET NEW PRE—FAB. CONCRETE LINTEL USING HIGH STRENGHT MORTAR. 4. REPAIR EXTERIOR/INTERIOR FINISHES; MAINTAIN REQUIRED FIRE RATING, (IF ANY). 5. FILL EXISTING CONCRETE BLOCKS AT EACH JAMB W/GROUT; PROVIDE CLEAN OUT AT BASE OF EACH JAMB TO ENSURE COMPLETE FILLING OF BLOCK CELLS. 6. THE CONCRETE LINTEL AND STEEL ANGLE SHALL BEAR A MIN. OF 8" ON EACH SIDE OF NEW OPENING. uu Section/Detail A-1 N.T.S. CHANGES IN LEVEL CHANGES IN LEVEL UP TO 1/4 INCH MAY BE VERTICAL AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BE N 1/4 INCH AND 1/2 INCH SHALL BE BEVELED WITH A SLOPE NO GRE�R THAN 1:2 (SEE FIGURES 28 AND 29). CHANGES IN LEVEL GREATER THAN 1/2 INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH CURB RAMPS AND RAMPS SECTIONS FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION CHAPTER 11, OF THE FLORIDA BUILDING CODE 2001 ED. 1/4 MAX. 1/4-1/2 ► ................................ FIG. 26 PERMIT # / 7- L? �(3 2 1 .... ...'' FIG. 29 'ONI z w� a� U w n O — NOD w� N E 1 SEfi r4RATE TENANT I=>b I\ A 'T n7 /tr Sol =I n%v--� i C/ Ak I I **-- * PROVIDE FIRE EXTINGUISHER(S) HAVING A MINIMUM RATING OF 2—A. 10—B.0 FOR EVERY 3,000 SQ. FT.; EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED AND READILY ACCESSIBLE. THE TOP OF THE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR AND THE BOTTOM OF EXTINGUISHER SHALL NOT BE LESS THAN 4 INCHES FROM THE FLOOR. TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. PROVIDE TACTILE EXIT SIGNAGE PER NFPA 101.7 10.13 BASEBOARDS TO PROTECT THE EDGES. ALL GROUT TO BE SEALED. TOP OF BASE TO WALL MUST BE CAULKED. ALL EXIT DOORS SHALL HAVE THE TYP. OF LOCK THAT CAN BE OPENED FROM THE INTERIOR AT ALI. TIMES, WITH OUT KEY, TYP. FIRE EXTINGUISHERS TO BE PROVIDED AS REQUIRED BY LOCAL AUTHORITIES (MIN. ONE NEAR EXITS), AT 4'-0' A.F.F. TERMITE PROTECTION. PROVIDE TERMITE PROTECTION AT ALL PLUMBING TRENCHING AND ALL PLACES OF SLAB BRACKAGE DURING CONSTRUCTION. BEARING PARTITIONS: EXISTING BEARING PARTITIONS TO MAINTAIN EXISTING INTEPRITY, NO CHANGES. FINISH SCHEDULE COORDINATE W/ OWNER ALL FINISHES, PUBLIC STORE FLOORING CERAMIC TILE PUBLIC STORE CEILING ACOUST I CAL CEILING PUBLIC STORE WALLS: PAINTED GYP. BD. OR BLOCK RESTROOMS FLOORING CERAMIC TILE RESTROOMS CEILING ACOUST I CAL CEILING RESTROOM WALLS: PAINTED CWP. BD. ABOVE, FRP BELOW RESTROOMS TO HAVE MOISTURE RESISTANT FINISH AT FIXTURE WALLS. WORK AREA FLOORING SEALED GONG. FLOOR** WORK AREA CEILING WASHABLE ACOUSTICAL CEILING WORK AREA WALLS: FRP COOLER FLOORING QUARRY TILE*** LEGEND - - - - - --- ----- - ----- _— DENOTES EXISTING OR "BASE—BUILDING" PARTITION TO BE REMOVED,. VERIFY CONDITION IN FIELD. DENOTES EXISTING OR "BASE—BUILDING" PARTITION TO REMAIN. VERIFY CONDITION IN FIELD. DENOTES EXISTING ASSUMED ONE (1) HOUR FIRE RATED WALL ASSEMBLY. GENERAL CONTRACTOR TO FIELD VERIFY AND TAKE CORRECTIVE ACTION AS REQUIRED. 3 DENOTES NEW NON—FIRE RATED DRYWALL PARTITION: A— 3 5/8" MET. STUDS AT 24" O.C. WITH ONE (1) LAYER 1/2- MIN. THICK GYPSUM BOARD EACH SIDE: FROM FLOOR SLAB TO CEILING., OR AS NOTED DENOTES NEW COOLER OR FREEZER PARTITION: DOOR AND HARDWARE DESIGNATION SYMBOL: DENOTES DOOR NUMBER DESIGNATION DENOTES HARDWARE TYPE. DENOTES DOOR TYPE DOOR WITHOUT SYMBOLS ARE EXISTING TO REMAIN. REFER TO DOOR SCHEDULE SHEET A-5. OPENINIG IN EXISTING CONC. BLK. WALL PROVISIONS FOR NEW OPENING IN EXISTING CONCRETE BLOCK WALL ELEVATION SECTION 1. CONTRACTOR TO BE RESPONSIBLE FOR SECURING & SHORING OF EXISTING WALL CONSTRUCTION AS REQUIRED TO MAINTAIN STRUCTURAL INTEGRITY OF EXISTING CONSTRUCTION. 2. SAW CUT POCKET FOR NEW PRE—FABRICATED CONCRETE LINTEL, & SAW CUT EXISTING MASONARY FROM INSIDE OF THE BUILDING. 3. SET NEW PRE—FAB. CONCRETE LINTEL USING HIGH STRENGHT MORTAR. 4. REPAIR EXTERIOR/INTERIOR FINISHES; MAINTAIN REQUIRED FIRE RATING, (IF ANY). 5. FILL EXISTING CONCRETE BLOCKS AT EACH JAMB W/GROUT; PROVIDE CLEAN OUT AT BASE OF EACH JAMB TO ENSURE COMPLETE FILLING OF BLOCK CELLS. 6. THE CONCRETE LINTEL AND STEEL ANGLE SHALL BEAR A MIN. OF 8" ON EACH SIDE OF NEW OPENING. uu Section/Detail A-1 N.T.S. CHANGES IN LEVEL CHANGES IN LEVEL UP TO 1/4 INCH MAY BE VERTICAL AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BE N 1/4 INCH AND 1/2 INCH SHALL BE BEVELED WITH A SLOPE NO GRE�R THAN 1:2 (SEE FIGURES 28 AND 29). CHANGES IN LEVEL GREATER THAN 1/2 INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH CURB RAMPS AND RAMPS SECTIONS FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION CHAPTER 11, OF THE FLORIDA BUILDING CODE 2001 ED. 1/4 MAX. 1/4-1/2 ► ................................ FIG. 26 PERMIT # / 7- L? �(3 2 1 .... ...'' FIG. 29 'ONI cn a� U w n O — NOD N o U0.0 m M M Q 0 0� 0 00 REVISIONS: per comments M11/24/1i per comments 4/5/18 per inspector 9/25/1 REV. 1/24/17 U Z F�— U W U Q O n elfQ N J U .Q 0 U 24X24 A D 41)0 50CFM VENTILATOR SCHEDULE MARK EF MANUFACTURER BROAN OR EQUAL MODEL NUMBER HD80 LOCATION MACH.ROOM SERVICE EXHAUST GALVANIZED STEEL SPIN -IN FITTING WITH AIR SCOOP AND INTEGRAL DAMPER TYPE DIRECT O CFM 100 ROOF TOP UNIT S.P. — CU RPM 1360 SUPPLY GRILL MOTOR HP 50 WATTS OSMOKE DRIVE TYPE DIRECT ® SONES 2.5 0.0M DUCT (IN.) 61'0 V/PH /60 120/1 0 CONTROL SWITCH Q� REMARKS 1 REMARKS 1. PROVIDE AND INSTALL WALL CAP WITH BIRD SCREEN. RAG 24X24 800CFM 14" @ IFIN rAi Zo/\Z"F a 1 / Z- UUI v U. MECHANICAL LEC -TEND SYM50L DESCRIPTION 0� NEW RIGID FIBERGLASS DUCT BOARD NEW FLEXIBLE FIBERGLASS DUCT CD CONTROL DAMPER � 14---/ -4400 GALVANIZED STEEL SPIN -IN FITTING WITH AIR SCOOP AND INTEGRAL DAMPER SAD 10'o MARK OF AIR DISTRIBUTION DEVICE AND CFM'S O THERMOSTAT RTU -1 ROOF TOP UNIT AHU AIR HANDLER UNIT CU COMPRESSOR UNIT e SUPPLY GRILL 06 RETURN GRILL OSMOKE DETECTOR Q ® EXHAUST FAN PARTIAL MECHANICAL PLAN 1/40* = 1'-0" HVAC PLAN NOTES 1Q RUN CONDENSATE FROM MECHANICAL UNITS TO ROOF DRAIN/GUTTER AND TERMINATE WITH APPROVED AIR GAP. REFER TO ARCHITECTURAL ROOF PLAN FOR LOCATION OF DRAINS/GUTTER. REFER CONDENSATE TRAP DETAIL ON MECHANICAL DETAIL SHEET FOR PIPE SIZE. REFER PIPE SUPPORT DETAIL ON MECHANICAL DETAIL SHEET FOR INSTALLATION. CONDENSATE PIPPING SHALL BE FROM THE APPROVED LIST OF MATERIALS AND CONSTRUCTION METHODS (2014 FLORIDA BUILDING MECHANICAL CODE) �3 CONDENSATE LINES NEED TO TERMINATE A MINIMUM OF 1 FOOT OUTSIDE OF EXTERIOR WALLS (FBCM 1503.4.4) AND THEY NEED TO TERMINATE IN AN APPROVED LOCATION. (FBCM 307) REVISIONS: -- - --_ - - Per comments 1-25-18 Per comments 3-08-18 Elect. as built 9-18-18 ---_.____._ _ _-------. MECH. CHANGES g-26-18 'ONI cn 0� U � LLJ 0 i O CLI I n N jM N Ir - 0600 06 Q 0 M 0.0M � LJ 0 Q Q� W U � A 0 i CLI I (') Oj 06 Q LJ Q Q� J 0 3 Q U 0 o z (y' Q 0. �r • �� UA N� • G REGIS fU' 1p* 0 Z H 0 W U ry Q O 0 ry a N J U L Q 0 U W. 4' SWIAA TO REMAIN EXIST. 4• GREASE TO RD" L' � rM Ar= A 7" � •"16 � k I A k IT' NU I L: ELECTRICAL CONTRACTOR SHALL VERIFY THE LOADS ON ALL EQUIPMENT BEFORE PURCHASING AND INSTALLING ANY AND ALL ELECTRICAL EQUIPMENT. NOTIFY ENGINEER OF ANY DISCREPANCIES. v r••••• lift I^ VV ILLI CABLE CONNECTION GARBAGE DISPOSAL MOTOR e EXHAUST FAN a JUNCTION BOX Fe DOOR BELL/GARAGE DOOR SWITCH REVISIONS: Per comments 11-25-18 Per comments 3-08-78 Elect. as built 9-18-18 MECH. CHANGES'g-2g-18 'ONI cn o� D U A Lv Lt I— O (') N ;M N-17 >- oOOD s ry (, oil M 5 M ^ H Q 0) O U� W U D A A ED > (') >- 0i M 06Q ry 5 H W ry ry J 0 I 3 Q � � U o o Z (y) Q oP , XN U Z v w Of a 0 0 ry a N J U 41 L O� T n 0 U LEGEND ® 4'x4' SKYLIGHT oF- TWO (2'X2') U 2'x4' FLUORESCENT LIGHT El 2'x2' FLUORESCENT LIGHT ® 1'x4' FLUORESCENT LIGHT ~ FLUORESCENT LIGHT JML SCONCE -�- WALL MOUNTED LIGHT O RECESSED LIGHT N PENDANT LIGHT ZZ TRACK LIGHTING A16= THEATRICAL STRIP 441, SPOT LIGHT tk EMERGENCY LIGHT ® EXIT LIGHT CEILING FAN W/ LIGHT ODM CEILING -MOUNTED INCANDESCENT LIGHT FIXTURE OPC CEILING -MOUNTED INCANDESCENT LIGHT FIXTURE W PULL CHAIN 48" MAX. HI. SINGLE POLE WALL SWITCH V- 0 0 U v 48" MAX. HI. 3 -WAY WALL SWITCH ® SINGLE -STATION SMOKE DETECTOR ® SMOKE & MONOXIDO DETECTOR REVISIONS: Per comments 1-25-18 Per comments `3-08-18 Elect. as built 9-18-18 i MECH. CHANGES :9-26-18 'ONI cn oF- U � W a> ~ n O n N �M N = p` 60D ry rM ODM H W V- 0 0 U v W U � A a> (y) ry H W ry r o 3 Q U CD o z (y' Q 1P 2017-11-10 2018-09-18 i1 ONE ONE LINE D IA,CsRAM E-5 u.� . xrs REVISIONS Per comments 1-25-18 Per comments ?3-08-18 Elect. as built 9-18-18 MECH. CHANGES 9-26-18 E i 'ONI cn E 0 F- I U lz� Ld >(') n 0 N N >- >M 06 �,dZ Q n M H W M ® Q T-0)0 0 Uv i i W U D lz� A >(') >- CU 06 Q H W r a 3 Q U 0 o 7F (Y) LLQ �Pv �o. Revision ❑ � Response to Comments Permit # i I 3 q Project Address: Contact: Ph: Email: Trades encompassed in revision: Building ❑ Plumbing ❑ Electrical ❑ Mechanical ❑ Life Safety ❑ Waste Water Uv City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Submittal Date LCL M � Fax: General description of revision: eCh . ROUTING INFORMATION Department Approvals ❑ Utilities ❑ Waste Water ❑ Planning ❑ Engineering ❑ Fire Prevention 13—Building t11E�CH' IiSt/�� ' U Z H U W U ry Q O 0 ry Q N J U .21a 0 0 E)OSf. 4' TO REMAI EXIST. 4' GREASE TO REMAIN I L — SAD -1 SAD -1 SAD -1 SAD -1 24X1 0 24X1 2 24X1 2 24X1 2 458CFM 450CFM 450CFM 450CFM W ky ky ky 25X1 2 1� 03 11At, 11 �IL�e Y[�IA, a', 50CFM RAG -1 SAD -1 24X24 24X1 2 5316CFM 450CFM �1f 25X20 a tt� ttt ttt tt� ttt SAD -1 SAD -1 SAD -1 SAD -1 SAD -1 24X1 0 24X1 2 24X1 2 24X1 2 24X1 2 458CFM 450CFM 450CFM 450CFM 450CFM 1 0X10 VERT. D 20 FT. LONG BRACED ON 2 SIDES W/ 4 x ANGLE 8x16 INLET GRILL EF 100CFM 1105.6.3 VENTILATION RATE: NOT LESS THAN 0.5 CFM SQUARE FEET OF MACHINARY ROOM 0.5 CFM/SFT X 170 SFT (AREA OR MACHINARY ROOM) = 85 CFM NOTE: PROVISIONS SHALL BE MADE FOR MAKEUP AIR TO REPLACE THAT BEING EXHAUSTED. OPENINGS FOR MAKEUP AIR SHALL BE LOCATED TO AVOID INTAKE OF EXHAUST AIR. SUPPLY AND EXHAUST DUCTS TO THE MACHINERY ROOM SHALL NOT SERVE ANY OTHER AREA, SHALL BE CONSTRUCTED IN ACCORDANCE WITH CHAPTER 5 AND SHALL BE COVERED WITH CORROSION—RESISTANT SCREEN OF NOT LESS THAN 1/4—INCH (6.4 MM) MESH. 50 SAD 24X24 8))0 200CFM '�`) A D 24X24 4))0 50CFM SAD 24X24 12" 0 450CFM VENTILATOR SCHEDULE MARK EF MANUFACTURER BROAN OR EQUAL MODEL NUMBER HD80 LOCATION MACH.ROOM SERVICE EXHAUST GALVANIZED STEEL SPIN -IN FITTING WITH AIR SCOOP AND INTEGRAL DAMPER TYPE DIRECT O CFM 100 ROOF TOP UNIT S.P. — CU RPM 1360 SUPPLY GRILL MOTOR HP 50 WATTS OSMOKE DRIVE TYPE DIRECT ® SONES 2.5 C I M DUCT (IN.) 6"0 0.* V/PH/60 120/1 0 0 O CONTROL SWITCH U..*i REMARKS 1 REMARKS 1, PR❑VIDE AND INSTALL WALL CAP WITH BIRD SCREEN, RAG 14 )) 0 24X24 8 0 0 C F M FAd00000 25X25 25X24 <= 1-1/2 )) COND. RTS ,4 f=1,4fRT I M _, 1/49t = 1'-0" MECHANICAL LEGEND S1'M50L DESCRIPTION 0E NEW RIGID FIBERGLASS DUCT BOARD NEW FLEXIBLE FIBERGLASS DUCT CD CONTROL DAMPER I� Lv GALVANIZED STEEL SPIN -IN FITTING WITH AIR SCOOP AND INTEGRAL DAMPER SAD -400 1000 MARK OF AIR DISTRIBUTION DEVICE. AND CFM'S O THERMOSTAT RTU -1 ROOF TOP UNIT AHU AIR HANDLER UNIT CU COMPRESSOR UNIT e SUPPLY GRILL RETURN GRILL OSMOKE DETECTOR U ® EXHAUST FAN C I M AL MECHANICAL FLAN HVAC PLAN NOTES 1Q RUN CONDENSATE FROM MECHANICAL UNITS TO ROOF DRAIN/GUTTER AND TERMINATE WITH APPROVED AIR GAP. REFER TO ARCHITECTURAL ROOF PLAN FOR LOCATION OF DRAINS/GUTTER. 0 REFER CONDENSATE TRAP DETAIL ON MECHANICAL DETAIL SHEET FOR PIPE SIZE. REFER PIPE SUPPORT DETAIL ON MECHANICAL DETAIL SHEET FOR INSTALLATION. CONDENSATE PIPPING SHALL BE FROM THE APPROVED LIST OF MATERIALS AND CONSTRUCTION METHODS (2014 FLORIDA BUILDING MECHANICAL CODE) �3 CONDENSATE LINES NEED TO TERMINATE A MINIMUM OF 1 FOOT OUTSIDE OF EXTERIOR WALLS (FBCM 1503.4.4) AND THEY NEED TO TERMINATE IN AN APPROVED LOCATION. (FBCM 307) PERMIT # I 1 — 3 c/ L3 REVISIONS: ........................................................... :.................... ......... Per comments 1-25-18 ........................... .............................. .::............................ Per comments 3-08-18 ........ ........................... ........................:............................. Elect. as built 9-18-18 ............. ..... ...................................... ..:.......... ................... MECH. CHANGES 9-26-18 ....................... ......................... ......:............................. MECH. CHANGES 11-27-1 f 'ONI w 0E - U Lv O n N N >M .� U 061 C I M 0.* QI 0 0 O U..*i W U � A 0 a- pq ()6 ry Q � W Q 3 o U o Z (y) Q LL oj I A ry L� Z Q 0 ip, U Z V U W U 0_ Q O 0 ry Q N J U rn T Q 0 U F L EXIST. 4' TO RE1W EXIST. 4' GREASE TO REIMN SAD -1 24X1 0 458CFM ky SAD -1 24X1 2 450CFM W 25X1 2 d SAD -1 24X1 2 450CFM SAD -1 24X1 2 450CFM )) �. A . - ��Lde ■SI , 0 50CFM RAG -1 SAD -1 24X24 24X12 5316CFM 450CFM 25X20 a tt� tt1 tt'� ttt tYt SAD -1 SAD -1 SAD -1 SAD -1 SAD -1 24X1 0 24X1 2 24X1 2 24X1 2 24X1 2 458CFM 450CFM 450CFM 450CFM 450CFM 1 0X10 VERT. D 20 FT. LONG BRACED ON 2 SIDES W/ 4 x ANGLE 8x16 INLET GRILL I� ❑ EF 100CFM 1105.6.3 VENTILATION RATE: NOT LESS THAN 0.5 CFM SQUARE FEET OF MACHINARY ROOM 0.5 CFM/SFT X 170 SFT (AREA OR MACHINARY ROOM) 85 CFM NOTE: PROVISIONS SHALL BE MADE FOR MAKEUP AIR TO REPLACE THAT BEING EXHAUSTED. OPENINGS FOR MAKEUP AIR SHALL BE LOCATED TO AVOID INTAKE OF EXHAUST AIR. SUPPLY AND EXHAUST DUCTS TO THE MACHINERY ROOM SHALL NOT SERVE ANY OTHER AREA, SHALL BE CONSTRUCTED IN ACCORDANCE WITH CHAPTER 5 AND SHALL BE COVERED WITH CORROSION—RESISTANT SCREEN OF NOT LESS THAN i/4—INCH (6.4 MM) MESH. 50 SAD 24X24 8))0 200CFM m 'S) A D 24X24 4))0 50CFM SAD 24X24 12" 4 450CFM VENTILAT0R SCHEDULE MARK EF MANUFACTURER BROAN OR EQUAL MODEL NUMBER HD80 LOCATION MACH.ROOM SERVICE EXHAUST TYPE DIRECT MARK OF AIR DISTRIBUTION DEVICE. AND CFM'S CFM 100 RTU -1 S.P. — AIR HANDLER UNIT RPM 1360 e MOTOR HP 50 WATTS RETURN GRILL DRIVE TYPE DIRECT 061 0 tc M SONES 2.5 EXHAUST FAN DUCT (IN.) 6"0 0 V/PH/60 120/1 CONTROL SWITCH REMARKS 1 REMARKS 1, PROVIDE AND INSTALL WALL CAP WITH BIRD SCREEN, A M-1 RAG 14 " 0 24X24 800CFM FAi( 25X25 25X24 a 1-112 )) COND. RTS F 1" ECHA lIC:AL LEC-sEND SYM50L DESCRIPTION 0F_ NEW RIGID FIBERGLASS DUCT BOARD NEW FLEXIBLE FIBERGLASS DUCT --� CD CONTROL DAMPER � Lv GALVANIZED STEEL SPIN -IN FITTING WITH AIR SCOOP AND INTEGRAL DAMPER SAD -400 1000 MARK OF AIR DISTRIBUTION DEVICE. AND CFM'S O THERMOSTAT RTU -1 ROOF TOP UNIT AHU AIR HANDLER UNIT CU COMPRESSOR UNIT e SUPPLY GRILL ry RETURN GRILL OSMOKE DETECTOR 061 0 tc M ® EXHAUST FAN PARTIAL MECHANICAL PLAN 1/4" = 1'-0" HVAC PLAN NOTES 1Q RUN CONDENSATE FROM MECHANICAL UNITS TO ROOF DRAIN/GUTTER AND TERMINATE WITH APPROVED AIR GAP. REFER TO ARCHITECTURAL ROOF PLAN FOR LOCATION OF DRAINS/GUTTER. REFER CONDENSATE TRAP DETAIL ON MECHANICAL DETAIL SHEET FOR PIPE SIZE. REFER PIPE SUPPORT DETAIL ON MECHANICAL DETAIL SHEET FOR INSTALLATION. CONDENSATE PIPPING SHALL BE FROM THE APPROVED LIST OF MATERIALS AND CONSTRUCTION METHODS (2014 FLORIDA BUILDING MECHANICAL CODE) 3� CONDENSATE LINES NEED TO TERMINATE A MINIMUM OF 1 FOOT OUTSIDE OF EXTERIOR WALLS (FBCM 1503.4.4) AND THEY NEED TO TERMINATE IN AN APPROVED LOCATION. (FBCM 307) PERMIT #,_ ,-? 3 'ONI cn 0F_ U � Lv �U 0 (') CL PCI N p c ao a pm� ry U 061 0 tc M 0 M 0 H W W U � A �U (') CL PCI M 06 ry Q H W ED 3 Q � � U Q CD z(y) Q L.L OPS, p`�1 �U OPS, p`�1 Revisio City of Sanford Response t Comments ❑ SEP 19 ZU16 Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Permit#- -" �JZ-� 1 Submittal Date Q 1 I`?-) Project A Contact: Ph: � % — �� ��' �� . , Fax: t Email: Trades encompassed in revision: ❑ Building ❑ Plumbing ,Electrical ❑ Mechanical General description of re a UPQ� :f �7w"/ J T�IE4,0 ❑ Life Safety . "°"-V ❑ Waste Water Y ROUTING INFORMATION Department Approvals ❑ Utilities ❑ Waste Water ❑ Planning ❑ Engineering ❑ Fire Prevention wilding !d U Z H U W I= U Ir Q O D Q N J 0 .21 T o_ 0 0 EXIST. 4' SAN[TAR TO REMAIN EXIST. 4' GREASE TO REMAIN L'�tm A= A-rn: rt�kI AKIl- REVISION #3 'ONI cn EH o� GARBAGE DISPOSAL MOTOR U Q A L1J DOOR BELL/GARAGE DOOR SWITCH F-1 > O (') Q_ PCI N �M N cu • E: P, (, c I 0 2M M F- U FD, H Q �^ O U ry W EH U GARBAGE DISPOSAL MOTOR EXHAUST FAN Q A A DOOR BELL/GARAGE DOOR SWITCH F-1 > (') Q_ PCI � cu 06 Q LL F- H W ry 3 Q � � U o o Z (y) Q L� VI V 1 L: ELECTRICAL CONTRACTOR SHALL VERIFY THE LOADS ON ALL EQUIPMENT BEFORE PURCHASING AND INSTALLING ANY AND ALL ELECTRICAL EQUIPMENT. NOTIFY ENGINEER OF ANY DISCREPANCIES. EH CABLE CONNECTION GARBAGE DISPOSAL MOTOR EXHAUST FAN Q JUNCTION BOX • DOOR BELL/GARAGE DOOR SWITCH U Z F_ U W F_ U Q O 0 Q N J U .21 L T a 0 U — 2 1/4" = 1'-0" AINU ZU- AMHLKL KLULH I AULLS, INULUUING I HDSL INSTALLED IN MODULAR PARTITIONS, INSTALLED IN FOLLOWING SPACE TYPES: A. PRIVATE OFFICES B. OPEN OFFICES C. COMPUTER CLASSROOMS SHALL BE CONTROLLED BY AN AUTOMATIC CONTROL DEVICE THAT SHALL FUNCTION ON: AN OCCUPANT SENSOR THAT SHALL TURN RECEPTACLES OFF WITHIN 30 MIN OF ALL OCCUPANTS LEAVING A SPACE ELECTRICAL NOTE: ALL EMERGENCY LIGHTS SHALL BE ON THE SAME CIRCUIT AS THE LIGHTING IN THE SAME ROOM, AHEAD OF THE SWITCH NOTE: ELECTRICAL CONTRACTOR SHALL VERIFY THE LOADS ON ALL EQUIPMENT BEFORE PURCHASING AND INSTALLING ANY AND ALL ELECTRICAL EQUIPMENT. NOTIFY ENGINEER OF ANY DISCREPANCIES. LEGEND INTO ELECTRICAL PANEL 0� ELECTRICAL METER ROA WALL MOUNTED DISCONNECT 18" MIN. HI. DUPLEX CONVENIENCE OUTLET. GFI� 18" MIN. HI. DUPLEX WATER PROOF OUTLET 42"(D:: GF1 42" MAX. HI. GFI COUNTER TOP CONVENIENCE OUTLET. I--® SPECIAL PURPOSE WALL OUTLET. ,4PH PHONE JACK QDATA DATA OUTLET N V) CABLE CONNECTION GARBAGE DISPOSAL MOTOR • EXHAUST FAN © JUNCTION BOX U DOOR BELL/GARAGE DOOR SWITCH REVISIONS: .............................. .........:.................. ........... Per comments 1 -25 -18 .......................................................... Per comments 3-08-18 ........ .............. .....................................:............................. Elect. as built 9-18-18 '0NI cn lo 0� x U LL, ~ n O l -J 1�..� N V) N4) Q • I..L U 0�I M C M H D Q 0O O a Uv W lo U x Q l -J 1�..� ICU I J I..L H D W v 3 Q � � U o o z (y' Q G4� ku lo °�' • CJ tri'•' x G4� ku LEGEND cn 4'x4' SKYLIGHT 0� T5HO (2'X2') ED2'x4' FLUORESCENT LIGHT Q 2'x2' FLUORESCENT LIGHT ® Vx4' FLUORESCENT LIGHT t====( FLUORESCENT LIGHT F- SCONCE �- WALL MOUNTED LIGHT 0 RECESSED LIGHT PENDANT LIGHT N TRACK LIGHTING �.G.a THEATRICAL STRIP ry SPOT LIGHT EMERGENCY LIGHT ® EXIT LIGHT CEILING FAN W/ LIGHT CEILING -MOUNTED INCANDESCENT LIGHT FIXTURE OPC CEILING -MOUNTED INCANDESCENT LIGHT FIXTURE W PULL CHAIN $ 48" MAX. HI. SINGLE POLE WALL SWITCH 48" MAX. HI. 3 -WAY WALL SWITCH ® SINGLE -STATION SMOKE DETECTOR ® SMOKE & MONOXIDO DETECTOR REVISIONS. - ................. 'DNI cn 0� "d U A W Ct F- O (') N ;M N >- 0i m 06 ry Q V M M n �..� Q a� O U LLJ U t A A (') >- 0i m 06 ry Q �..� W 0 3 Q U 0 CD Z M Q L� A it t `•` A it SEPARATE TENANT IvIvvII...li /I I ii'i'vrl\ LI III\I nIVV LI IIVI 1 1 1\IJIVI I IuLJULLL U1\ L_WUrAL. VU IVU I I�UIVIVLU I ANY EM ER GEN CY LIGHT OR EX T SIGN AFTER THE LIGHTING SENSOR. iI PARTIAL LIGHTING FLAN II E-4� ,i. -1-o LIGHTING SCHEDULE Mark I Manufacturer # X SIMKAR SLED -B -R -W -EXIT EM SIMKAR DLM11V B SIMKAR ETY24P3035U1 C IEWIROLITEST-/04T1850 127 1 I I I ----------_ III LEGEND ELECTRICAL NOTE: ALL EMERGENCY LIGHTS SHALL BE ON THE SAME CIRCUIT AS THE LIGHTING IN THE SAME ROOM, AHEAD OF THE SWITCH 4'x4' SKYLIGHT 0� Description !. Lamps F Mount Volts 2'x4' FLUORESCENT LIGHT NOTE: ELECTRICAL CONTRACTOR SHALL VERIFY THE ON ALL EQUIPMENT BEFOREPURCHASING AND INSTALLING ANY AND ALL ELECTRICAL EQUIPMENT. NOTIFY ENGINEER OF ANY DISCREPANCIES. I Qty. Type EXIT LIGHT SELF DIAGNOSTIC BATTERY BACKUP- 90 EMERG. ILLUMINATION 1 3W SURFACE 1201277 INTERIORMINUTES EMERGENCY LIGHT, TWIN HEAD -90 MIN EMERG ILLUP,1. 2 5.4W SURFACE 12l277 INTERIORLOADS 2'X4' RECESSED LED FLUORESCENT 2 59N' RECESSED 1201277 INTERIOR 8 FT 4 LIGHTS LED STRIP LIGHT T8 4 224W STRIP 120/277 INTERIOR III LEGEND ® 4'x4' SKYLIGHT 0� T5HO (2'X2') 2'x4' FLUORESCENT LIGHT El LIJ 2'x2' FLUORESCENT LIGHT ® 1'x4' FLUORESCENT LIGHT FLUORESCENT LIGHT __N SCONCE __9— WALL MOUNTED LIGHT O RECESSED LIGHT PENDANT LIGHT >_ �.�.� TRACK LIGHTING �..G.G THEATRICAL STRIP SPOT LIGHT Ikk EMERGENCY LIGHT ® EXIT LIGHT CEILING FAN W/ LIGHT 6 n CEILING—MOUNTED INCANDESCENT LIGHT FIXTURE ��{{ OPC CEILING—MOUNTED INCANDESCENT LIGHT FIXTURE W PULL CHAIN 48" MAX. HI. SINGLE POLE WALL SWITCH U 48" MAX. HI. 3—WAY WALL SNATCH ® SINGLE—STATION SMOKE DETECTOR ® SMOKE & MONOXIDO DETECTOR 'ONI cn 0� U LIJ ED > r N >_ 0i M o2S ry Q 061 C L M 0.2 M 6 n H W aUi O !� Q U W U Ul ED > (y) >_ 0i M o2S ry Q H W r J 0 3 Q U O 0 z M Q Ul 0 Z H 0 W F -- C) ry 0 0 Q N J 0 L rn .T a 0 0 PANEL SCHEDULE ARTICLE 220) NEW PANEL B LOAD CALCULATION CONNECTED KVA DEMAND FACTOR DEMAND LOAD FOOD SERVICE EQUIPMEN 0.0 0.65 0.0 LIGHTING 0.00 LOAD BALANCE DATA NEW PANEL: "L" BUS:200 AMP _8.88 0.00 1.00 LOAD BALANCE DATA SUB PANEL: "L-1" VOLTAGE: 120/208V,3�,4W A = 66.0 AMPS = :7.9 KVA MOUNTING: SURFACE POLES: 42 60 3 45.0 VOLTAGE: 120/208V,30,4W TOTAL DEMAND VOLTAGE: 120/208,3 -PHASE 24.8 360 A = 42.0 `AMPS = '5.0 KVA MOUNTING: SURFACE 68.83 B = :60.0 AMPS - 7.2 KVA LOCATION: SEE PLANS REMARKS: 200 AMP MLO PANEL "B" 150 1 3 47.7 17 120-208 RTU -1 C = .62.0 AMPS = 7.4 KVA 200 LOAD (AMPS) B = :46.0 :AMPS = 5.5 KVA LOCATION: SEE PLANS 120-208 "L" REMARKS: 100 AMP MLO 3 68.6 LOAD (AMPS) TOTAL CONNECTED LOAD = 22.6 KVA DESCRIPTION A B C TRIP WIRE POLES CIRC LEG CIRC POLES WIRE TRIP A B C DESCRIPTION ITOTAL CONNECTED LOAD = 261.2 KVA 20 12 1 1 A 2 1 12 20 A B C 20 12 1 3 B 4 1 12 20 C DESCRIPTION WRAPPER 20 12 1 5 C 6 1 12 20 1 12 20 20 12 1 7 A 8 1 12 20 12 1 3 20 12 1 9 B 10 1 12 20 E. CASE COOLER SPARE RTU -1 175 20 12 1 11 C 12 1 12 20 20 200 93.0 20 12 1 13 A 14 1 12 20 7 A 8 20 12 1 15 B 16 1 12 20 12 3 20 20 12 1 17 C 18 1 12 20 12 200 W. CASE FREEZER 20 12 1 19 A 20 1 12 20 12 1 12 20 12 1 21 B 22 1 12 20 20 12 1 20 12 1 23 C 24 1 12 20 W. ISLAND F/H E. ISLAND- SPARE WEST EXIT-EMER STORE LTS 10 20 12 1 25 A 26 1 12 20 3 E. STORAGE EMER LTS WEST EXIT-EMER STORE LTS 3 20 12 1 27 B 28 1 12 20 3 E. STORAGE EMER LTS WEST EXIT-EMER STORE LTS 3 20 12 1 29 C 30 1 12 20 3 E. STORAGE EMER LTS STORAGE EXIT-EMER LTS 3 20 12 1 31 A 32 1 12 20 8 FREEZER & WIC LTS STORAGE LTS SPARE 8 20 12 1 33 1 B 34 1 12 20 B 22 STORAGE LTS TIMER 8 20 1 12 1 1 1 35 C 36 1 12 20 6 20 12 20 12 1 37 A 38 3 2 100 42 OFFICE SUB PNL L1 CASHIR #4 20 12 1 39 B 40 3 2 100 46 OFFICE SUB PNL L1 20 20 12 1 1 41 C 42 3 2 100 48 OFFICE SUB PNL L1 PANEL SCHEDULE ARTICLE 220) NEW PANEL B LOAD CALCULATION CONNECTED KVA DEMAND FACTOR DEMAND LOAD FOOD SERVICE EQUIPMEN 0.0 0.65 0.0 LIGHTING 0.00 1.25 11.1 HVAC _8.88 0.00 1.00 LOAD BALANCE DATA SUB PANEL: "L-1" 13.68 1 1.00 BUS: 100 AMP 200 AMP 60 3 45.0 VOLTAGE: 120/208V,30,4W TOTAL DEMAND VOLTAGE: 120/208,3 -PHASE 24.8 360 A = 42.0 `AMPS = '5.0 KVA MOUNTING: SURFACE 68.83 47.67 POLES: 42 "B" PANEL "B" 150 1 3 47.7 17 120-208 RTU -1 ROOF TOP UNIT 200 3 B = :46.0 :AMPS = 5.5 KVA LOCATION: SEE PLANS 120-208 "L" REMARKS: 100 AMP MLO 3 68.6 25 120-208 I - ---- *UTILIZE 200 AMP SERVICE z i C= '48.0 AMPS = :5.8 :KVA LOAD (AMPS) LOAD (AMPS) ITOTAL CONNECTED LOAD = 261.2 KVA DESCRIPTION A B C TRIP WIRE POLES LOAD (AMPS) TOTAL CONNECTED LOAD = 16.3 KVA DESCRIPTION A B C TRIP WIRE POLES CIRC LEG CIRC POLES WIRE TRIP A B C DESCRIPTION WRAPPER 3 20 12 1 1 A 2 1 12 20 12 4 W. CASE COOLER WRAPPER 3 RACK COMP. 20 12 1 3 B 4 1 12 20 8 W. CASE COOLER E. CASE COOLER SPARE RTU -1 175 6 20 12 1 5 C 6 1 12 20 200 93.0 12 W. CASE COOLER MEAT COOLER 6 200 20 12 1 7 A 8 1 12 20 12 RTU -1 W. CASE FREEZER MEAT COOLER 200 12 3 20 1 12 1 9 B 1 10 1 12 20 12 200 W. CASE FREEZER MEAT COOLER SPARE 13 A 16 20 12 1 11 C 12 1 12 20 200 30 12 W. CASE FREEZER E. ISLAND- SPARE 13 3 30 20 12 1 13 A 14 1 12 20 10 17 C W. ISLAND F/H E. ISLAND- SPARE 30 12 45.0 20 12 1 15 B 16 1 12 20 A 10 W. ISLAND F/H E. ISLAND OMEN= 16 20 12 1 17 C 18 1 1 12 20 10 W. ISLAND F/H CASHIR #5 6 20 1 12 1 19 A 20 1 12 20 6 SPARE CASHIR #5 6 20 12 1 21 B 22 1 12 20 6 SPARE CASHIR #4 6 20 12 1 23 C 24 1 12 20 6 SPARE CASHIR #4 6 20 12 1 25 A 26 1 12 20 6 E. NIGHT LIGHTS CASHIR #3 6 20 12 1 27 B 28 1 12 20 8 W. NIGHT LIGHTS CASHIR #3 6 20 12 1 29 C 30 1 12 20 8 SHOW WINDOW & DOOR CASHIR #2 6 20 12 1 31 A 32 1 12 20 6 CUSTOMER SERVICE & MED. INSUR. CASHIR #2 6 20 12 1 33 B 34 1 12 20 6 OFFICE RECEPT. CASHIR #1 6 20 12 1 35 C 36 1 12 20 6 DELI QUAD CASHIR #1 6 20 12 1 37 A 38 1 12 20 6 CUSTOMER SERVICE RECEPT. LIGHTS Em 8 20 12 1 39 1 B 40 1 12 20 6 CUSTOMER SERVICE RECEPT. SIGN TIMER 10 1 20 12 1 41 C 42 1 12 20 6 QUAD LOAD CALCULATION (N.E.C. ARTICLE 220) NEW PANEL "L" ARTICLE 220) NEW PANEL B LOAD CALCULATION CONNECTED KVA DEMAND FACTOR DEMAND LOAD FOOD SERVICE EQUIPMEN 0.0 0.65 0.0 LIGHTING 0.00 1.25 11.1 HVAC _8.88 0.00 1.00 0.0 RECEPTACLES AND MISC 13.68 1 1.00 13.68 200 AMP 60 3 45.0 ... ......._ .. ...... . TOTAL DEMAND VOLTAGE: 120/208,3 -PHASE 24.8 360 ..................... .................. DEMAND AMPS *UTILIZE 200 AMP SERVICE 68.83 PANEL SCHEDULE ARTICLE 220) NEW PANEL B BREAKER TRIP POLES LOAD CALCULATION I CONNECTED KVA DEMAND FACTOR DEMAND LOAD_ iFOOD SERVICE EQUIPMENI 7.2 0.65 4.7 i LIGHTING 0.00 1.25 0.0 HVAC 0.00 1.00 LOAD BALANCE DATA NEW PANEL: "B" 12.48 1.00 BUS: 200 AMP 60 3 45.0 ... ......._ .. ...... . VOLTAGE: 120/208V,30,4W 17.2 360 ..................... .................. A = 64.0 :AMPS = 7.7 KVA MOUNTING: SURFACE 47.67 34 POLES: 42 "B" PANEL "B" 150 1 3 47.7 17 120-208 RTU -1 ROOF TOP UNIT 200 3 B = 64.0 AMPS 7.7 KVA LOCATION: SEE PLANS 120-208 "L" REMARKS: 200 AMP MLO 3 68.6 25 120-208 I - ---- *UTILIZE 200 AMP SERVICE z i C = '45.0 AMPS 5.4 KVA LOAD (AMPS) LOAD (AMPS) ITOTAL CONNECTED LOAD = 261.2 KVA DESCRIPTION A B C TRIP WIRE POLES LOAD (AMPS) TOTAL CONNECTED LOAD = 20.8 KVA DESCRIPTION A B C I TRIP IWIRE POLES CIRC LEG CIRC POLES WIRE TRIP A B C DESCRIPTION WRAPPER 3 20 12 2 1 A 2 1 12 20 12 4 W. CASE COOLER WRAPPER 3 RACK COMP. 20 12 2 3 B 4 1 12 20 8 W. CASE COOLER E. CASE COOLER SPARE RTU -1 175 6 20 12 2 5 C 6 1 12 20 200 93.0 12 W. CASE COOLER MEAT COOLER 6 200 20 12 2 7 A 8 1 12 20 12 RTU -1 W. CASE FREEZER MEAT COOLER 200 12 3 20 12 1 9 B 10 1 12 20 12 200 W. CASE FREEZER MEAT COOLER SPARE 13 A 16 20 12 2 11 C 12 1 12 20 200 30 12 W. CASE FREEZER E. ISLAND- SPARE 13 3 30 20 12 2 13 A 14 1 12 20 10 17 C W. ISLAND F/H E. ISLAND- SPARE 30 12 45.0 20 12 1 15 B 16 1 12 20 A 10 W. ISLAND F/H E. ISLAND OMEN= 16 20 12 1 17 C 18 1 12 20 10 W. ISLAND F/H MEAT CUTTING GFCI 3 20 12 1 19 A 20 1 12 20 6 BATH ROOM LIGHTS & GFCI RECEPT. MEAT CUTTING GFCI 3 20 12 1 21 B 22 1 12 20 6 N. STORAGE RECEPT. COLUM RECEPT. 3 20 12 1 23 C 24 1 12 20 6 IWATER FOUNTAIN WATER HEATER 22 30 1 10 2 25 A 26 3 12 45 6 CARTON COMPACTOR WATER HEATER 22 30 10 2 27 B 28 3 12 45 6 CARTON COMPACTOR E. STORAGE QUAD 6 20 12 1 29 C 30 3 12 45 6 CARTON COMPACTOR E. STORAGE QUAD 6 20 12 1 31 A 32 3 12 20 6 MEAT SLICER MEAT CUTTING GFCI 6 20 12 1 33 B 34 3 12 20 6 MEAT SLICER MEAT CUTTING GFCI 6 20 12 1 35 C 36 3 12 20 6 MEAT SLICER MEAT GRINDER 6 30 10 3 37 A 38 3 12 20 6 MEAT SLICER MEAT GRINDER Em 6 30 10 3 39 B 40 3 12 20 6 MEAT SLICER MEAT GRINDER 6 30 10 3 41 C 42 3 12 20 6 MEAT SLICER LOAD CALCULATION (N.E.C. ARTICLE 220) NEW PANEL B BREAKER TRIP POLES LOAD CALCULATION I CONNECTED KVA DEMAND FACTOR DEMAND LOAD_ iFOOD SERVICE EQUIPMENI 7.2 0.65 4.7 i LIGHTING 0.00 1.25 0.0 HVAC 0.00 1.00 0.0 RECEPTACLES AND MISC 1 12.48 1.00 12.48 RACK CONDENSER 60 3 45.0 ... ......._ .. ...... . TOTAL DEMAND VOLTAGE: 120r208,3 -PHASE 17.2 360 ..................... .................. 200 DEMAND AMPS *UTILIZE 200 AMP SERVICE 47.67 TOTAL LOAD: MARK NAMEPLATE DESCRIPTION BREAKER TRIP POLES LOAD AMPS LOAD KVA VOLTAGE i OD SERVICE EQUIPMENI 0.0 0.65 W 0.0 a RACK COMP RACK COMPRESSORS 350 3 289.0 104 120-208 RACK COND RACK CONDENSER 60 3 45.0 16 120-208 "A" PANEL "A" 200 3 93.2 34 120-208 "B" PANEL "B" 150 1 3 47.7 17 120-208 RTU -1 ROOF TOP UNIT 200 3 175.0 63 120-208 "L" PANEL "L" 200 3 68.6 25 120-208 I - ---- *UTILIZE 200 AMP SERVICE z i C = .110.0 AMPS = 13.2 KVA LOAD (AMPS) LOAD (AMPS) ITOTAL CONNECTED LOAD = 261.2 KVA DESCRIPTION A B C TRIP WIRE POLES LOAD (AMPS) TOTAL CONNECTED LOAD = 34.7 KVA 258.65 718.47... TOTAL LOAD (KVA) TOTAL LOAD (AMPS) Q11rA210111 PANEL SCHEDULE cn LOAD CALCULATION ICONNECTED KVA DEMAND FACTOR DEMAND LO OD SERVICE EQUIPMENI 0.0 0.65 W 0.0 a ,FOS LOAD BALANCE DATA NEW MDP PANEL LOAD BALANCE DATA NEW PANEL: "A" BUS: LIGHTING BUS: 200 AMP = 11.1 VOLTAGE: 120/208V,34),4W HVAC VOLTAGE: 120/208V,30,4W 1.00 A = 93.0 AMPS = :11.2 KVA MOUNTING: SURFACE RECEPTACLES AND MISC 22.44 POLES: 42 22.44 H Q U* B = :719.0 :AMPS = .86.3 KVA LOCATION: SEE PLANS REMARKS: TOTAL DEMAND B = .86.0 'AMPS = 10.3 KVA LOCATION: SEE PLANS VOLTAGE: 120/208,3 -PHASE 1 REMARKS: 200 AMP MLO .................. ..._.. DEMAND AMPS - -------------- V J 93.17 I - ---- *UTILIZE 200 AMP SERVICE z -- C = .110.0 AMPS = 13.2 KVA LOAD (AMPS) LOAD (AMPS) ITOTAL CONNECTED LOAD = 261.2 KVA DESCRIPTION A B C TRIP WIRE POLES LOAD (AMPS) TOTAL CONNECTED LOAD = 34.7 KVA DESCRIPTION A B C TRIP WIRE POLES CIRC LEG CIRC POLES WIRE TRIP AB 1 C DESCRIPTION E. CASE COOLER 6 20 12 1 1 A 2 1 12 20 12 4 W. CASE COOLER E. CASE COOLER 6 RACK COMP. 20 12 1 3 B 4 1 12 20 8 W. CASE COOLER E. CASE COOLER SPARE RTU -1 175 6 20 12 1 5 C 6 1 12 20 200 93.0 12 W. CASE COOLER MEAT COOLER 6 200 20 12 1 7 A 8 1 12 20 12 RTU -1 W. CASE FREEZER MEAT COOLER 200 12 3 20 1 12 1 9 B 10 1 12 20 12 200 W. CASE FREEZER MEAT COOLER SPARE 13 A 16 20 12 1 11 C 12 1 12 20 200 30 12 W. CASE FREEZER E. ISLAND- SPARE 13 3 30 20 12 1 13 A 14 1 12 20 10 17 C W. ISLAND F/H E. ISLAND- SPARE 30 12 45.0 20 12 1 15 B 16 1 12 20 A 10 W. ISLAND F/H E. ISLAND OMEN= 16 20 12 1 17 C 18 1 12 20 10 W. ISLAND F/H PRODUCE COOLER EVAPORATO 10 20 12 1 19 A 20 1 12 20 10 ROOF COND. GFCI DAIRY COOLER EVAPORATOR 5 20 12 1 21 B 22 1 12 20 5 W. CASE FREEZER HEATER MEAT COOLER EVAPORATOR 10 20 12 1 23 C 24 2 12 20 7 FREEZER EVAP. 20 12 1 25 A 26 2 12 20 7 FREEZER EVAP. 20 12 1 27 B 28 1 12 20 8 FREEZER HEAT GFCI 20 12 1 29 C 30 2 12 20 7 FREEZER EVAP. 20 12 1 31 A 32 2 12 20 7 FREEZER EVAP. 20 12 1 33 B 34 2 12 15 8 CUTTING ROOM EVAP. 20 12 1 35 C 36 2 12 15 8 CUTTING ROOM EVAP. 20 12 1 37 A 38 1 12 20 Em 20 12 1 1 39 B 40 1 12 20 20 1 12 1 1 41 C 1 42 1 12 20 111111M 6.0 W- ISLAND F/H LOAD CALCULATION (N. E. C. ARTICLE 220) NEW PANEL A cn LOAD CALCULATION ICONNECTED KVA DEMAND FACTOR DEMAND LO OD SERVICE EQUIPMENI 0.0 0.65 W 0.0 a ,FOS LOAD BALANCE DATA NEW MDP PANEL ' n BUS: LIGHTING 8.88 1.25 = 11.1 VOLTAGE: 120/208V,34),4W HVAC 0.00 1.00 0.0 RECEPTACLES AND MISC 22.44 1.00 22.44 H Q U* B = :719.0 :AMPS = .86.3 KVA LOCATION: SEE PLANS REMARKS: TOTAL DEMAND 33.5 VOLTAGE: 120/208,3 -PHASE 1 360 .................. ..._.. DEMAND AMPS - -------------- V J 93.17 I - ---- *UTILIZE 200 AMP SERVICE z -- PANEL SCHEDULE cn 0F_ w 'u; U ej IN W a > LOAD BALANCE DATA NEW MDP PANEL ' n BUS: 800AMP � M N = 0000 VOLTAGE: 120/208V,34),4W A = :732.0 AMPS = ii 87.8 KVA MOUNTING: SURFACE IPOLES. 24 � m M 0-0 � 0 o 0 H Q U* B = :719.0 :AMPS = .86.3 KVA LOCATION: SEE PLANS REMARKS: 800 AMP MLO Q C = :726.0 TAMPS = :87.1 f KVA V J LOAD (AMPS) I z (y' Q LOAD (AMPS) ITOTAL CONNECTED LOAD = 261.2 KVA DESCRIPTION A B C TRIP WIRE POLES CIRC LEG CIRC POLES WIRE TRIP A I B I C IDESCRIPTibN RACK COMP. 289 350 400 3 1 A 2 RACK COMP. 289 350 400 3 3 B 4 RACK COMP. 289 350 400 3 5 C 6 RTU -1 175 200 30 3 7 A 8 3 30 200 93.0 PANEL "A" RTU -1 175 200 30 3 9 B 10 3 30 200 86.0 PANEL "A" RTU -1 175 200 30 3 11 C 12 3 30 200 110.0 PANEL "A" PANEL "L" 66.0 200 30 3 13 A 14 3 30 200 64.0 PANEL "B" PANEL "L" 60.0 200 30 3 15 B 16 3 30 200 64.0 PANEL "B" PANEL "L" 62.0 200 30 3 17 C 18 3 30 200 45.0 PANEL "B" RACK COND. 45 60 4 3 19 A 20 1 OMEN= RACK COND. 45 a= 60 4 3 21 B 22 RACK COND. 45 1 60 4 3 23 C 1 24 2018-09-18 iI ONE ONE LINE D IACsRAM E-5 sac - .s 'ONI cn 0F_ w 'u; U ej IN W a > n 0 ' n PCI � M N = 0000 ,max t..L V 0M � m M 0-0 � 0 o 0 H Q U* W G�, U w 'u; ej IN Q a > ' (.Y)OL PCI n�'' l VV (-Y) _, ,max t..L H W 0 Q V J U C) o z (y' Q N G�, o� w 'u; ej IN N