HomeMy WebLinkAbout1265 Upsala Rd 18-2038 #1165 (a)PANGOLIN I ASF -,R SYSTF,.MS Inc. TENANT IMPROVMENTS 1265 UPSALA ROAD, SUITE 1165 Sa'nford,'32771 City of sonford L6 Oil and Grease Program Initials & Date - SHEET INDEX LOCATION MAP NUMBER SHEET TITLE PERMIT ISSUE REVISED REVISED COVER SHEET & INDEX 02-23-18 ARCHITECTURAL A 101 LIFE SAFETY PLAN & ANALYSIS 02-23 18 .. A 102 FIRST FLOOR PLAN 02-23-18 February 23 201.5 r x. MECHANICAL M-001 ABBRE, NOTES & LEGEND - MECHANICAL 02-23-18 M-201 FLOOR PLAN - MECHANICAL 02-23-18 j , M-301 SCHEDULES &DETAILS -MECHANICAL 02-23-1$ `sem i t- 5 M-401 DETAILS -MECHANICAL 02-23-18 p fly M-501 SPECIDFICATIONS - MECHANICAL 02-23-18 YW jz"1{ Z y,t isbc ' Y � ^ .. ��' ' 1 .,,.� *> s •' spa � s x � 39- ��� -" ''"s' s x PLUMBING `�„ _ ' OWNER BENNER LASER �� '��, .. P-001 SYMBOLS LEGEND &NOTES - PLUMBING 02-23-18 1265 UPSALA ROAD, SUITE 1165° Y P-201 FLOOR PLAN - PLUMBING 02-23-18 Sanford, Florida 32771 ;� � .} � 4 � ��� � �; ,�';�_ � ��� � n � � � �,. �- ��. � ��bP""n.,.; '4�` � rl P 301 SCHEDULES, DETAILS &RISER -PLUMBING 02-23-18 _ ARCHITECT BLANKENSHIP ARCHITECTS INCORPORTATED NORTH ELECTRICAL 540 Lake Faith Circle NO SCALE Maitland, Florida 32751 E-001 SYMBOLS, LEGEND & NOTES - ELECTRICAL 02-23-18 Phone 407.331.8868 E-201 FLOOR PLAN - ELECTRICAL 02-23-18 nelson@blankenshiparchitects.com r E-301 RISER DIAGRAM &SCHEDULES -ELECTRICAL 02-23-18 E-401 DETAILS -ELECTRICAL 02-23-18 JOSEPH LAWRENCE & CO LLC GENERAL N 0 1' E S JOS E-501 SPECIFICATIONS - ELECTRICAL 02-23-18 MECHANICAL 138 WEST JESSUP AVENUE ELECTRICAL & LONGWOOD, FL 32750 PLUMBING 321.972.4466 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES, SPECIFIC BUILDING RESTRICTIONS AND INDUSTRY CONSTRUCTION INGENGINEER CONTACT: ADAM BARNEY STANDARDS AND SPECIFICATIONS. 407.454.1911 CELL 2. FOR THESE DOCUMENTS, THE TERMS'OWNER' AND 'TENANT' ARE INTERCHANGEABLE. 4 GENERAL CONTRACTOR JL STONE CONSTRUCTION 3. GENERAL CONTRACTOR IS TO MAINTAIN LIFE SAFETY AND EMERGENCY EGRESS FUNCTIONALITY DURING CONSTRUCTION. GC SHALL 123 North Industrial Drive PROVIDE CONSTRUCTION BARRIERS AS REQUIRED AND COORDINATE WITH TENANT. Orange City, Florida 32763 Phone 386.473.0161 Swoape 4. DIMENSIONS AND CONDITIONS INDICATED IN THESE DRAWINGS ARE BASED ON DOCUMENTS AND INFORMATION PROVIDED. GC SHALL Contact: Bryan Swoape VERIFY EXISTING ACTUAL CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT / TENANT OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIALS AND COMMENCEMENT OF WORK. 540 LAKE FAITH CIRCLE 5. PROTECT ALL EXISTING MATERIALS AND FURNISHINGS DESIGNED TO REMAIN. DAMAGED ITEMS SHALL BE REPLACED COMPLETELY BY B LANKEN S HIP y qF MAITLAND, FL 32751 THE GENERAL CONTRACTOR TO THE ITEMS CONDITION AT COMMENCEMENT OF THE PROJECT. CONSTRUCTION PERFORMED ADJACENT TO Px. 407.331.8868 EXISTING MATERIALS SHALL BLEND IN TEXTURE FINISH AND COLOR WHEN FINISHED SO AS TO NOT BE DETECTABLE. FX. 407.599.2884 ARCHITECTS Registration AA 26001666 nelson@blankenshiparchitects.com 6. IF POWER MUST BE CUT OFF TEMPORARILY, NOTIFY THE TENANT 24 HOURS MINIMUM IN ADVANCE OF THE SCHEDULED CUT OFF TIME. INCORPORATED ORATED copyright Q 7. DURING CONSTRUCTION, GENERAL CONTRACTOR SHALL PARK VEHICLES AND EQUIPMENT, ETC. IN A LOCATION APPROVED BY TENANT. 8. DIMENSIONS SHOWN ARE TO FACE OF CONCRETE, CONCRETE MASONRY UNITS (CMU) OR FACE OF STUDS UNLESS NOTED OTHERWISE (UNO). p;?�aQD BORLDIv ali/iSIO�J PERMIT # �9 ' "p 6 A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS �y AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES. NOR SHALL ISSUANCE OF A PERMIT PREVENT' HE BUILDING OFFICIAL FROM THEREAFTER �< < REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE OFFICE THI5 PROJECT IS THE MODIFICATION OF AN EXISTING OFFICE AND STORAGE SPACE INTO OFFICES FIRST FLOORI WITH AND ANOTHER TOILET. AA3,B29 SF WITH SPACES. PROJECT MEZZAN NIELARY OF 460 SF. ARE ADDED TOFIRST FLOOR AND ONE HAS NO WORK WALLOF SINGLE TOILET ROOM. CONSTRUCTION CONSISTS OF GWB WALLS WITH METAL STUDS, RESILIENT TILE DESCRIPTION FLOORS AND LAY -IN CEILINGS, TOILET WAS FINISHED LIKE EXISTING WITH TILE FLOOR AND WAINSCOT. CODE ANALYSIS CODES IN EFFECT FLORIDA BUILDING CODES, 6 TH EDITION FLORIDA FIRE PREVENTION CODE, 6tH EDITION NATIONAL ELECTRIC CODE 2014 Applicable State, Federal and Local Codes and Regulations 5U5JECT REFERENCE - APPLICATION PROVIDED OCCUPANCY SECTION 304.1 - OFFICES - BUSINESS CONSTRUCTION TYPE TABLE 601 - TYPE V B TYPE V B SPRINKLED AUTOMATIC SPRINKLER REQUIRED - PROVIDED FULLY SPRINKLED ALLOWABLE BUILDING AREA MAX BUSINESS - 23,000 SF PER FLOOR FIRST FLOOR 3029 SF . (per floor) BUSINESS B - 23,000 X 3 - 69,000 SF MEZZANNE 460 SF CLASSIFICATION SEPARATION SECTION 1083 - TENANT SEPARATIONS EXISTING I HR HEIGHT MAX TABLE 503 - 55 FT PLUS 20 = 15 FT 30 FT EXISTING EXITS REQUIRED SECTION 1015.1 - I - 500 = 2 FIRST FL -2 MEZZANINE - 1 EXIT TRAVEL MAX TABLE 10162 - BUSINESS - 300 FT (SPRK) 16 FT CORRIDOR DEAD END LIMIT SECTION 1018.4, EXCPT 2 50 FT NONE FIRE RESISTANCE RATINGS BUILDING ELEMENTS t:. Cr PRIMARY STRUCTURAL FRAME TABLE 601 - 0 HR 0 HR BEARING WALLS EXTERIOR , 30 FT TABLE 602 - 0 HR 0 HR NON BEARING WALLS EXTERIOR TABLE 601 - 0 HR 0 HR NON BEARING WALLS INTERIOR TABLE 601 - 0 HR 0 HR FLOOR CONSTRUCTION TABLE 601 - 0 HR 0 HR, I HR PER NFPA ROOF CONSTRUCTION TABLE 601 - 0 HR 0 HR EGRESS (occupant load) TABLE 1004.12 - EGRESS REQUIREMENTS FIRST FLOOR 3,829 SF / 100 PER = 39 PEOPLE I—+ TOTALPERSONS = 44 MEZZANINE 460 SF / 100 PER = 5 PEOPLE TOTAL = 44 PEOPLE ct CALCULATION OF EXIT DOOR WIDTHS FIRST FLOOR FIRST FLOOR 39 X .15 = 5.9' 2 SINGLE DRS, 2X 32' 64' MEZZANINE 5 X 20 + 1' MEZZANINE I STAIR DR I X 32' = 32' PLUMBING FIXTURE REQUIREMENTS TABLE 403.1 - F1_OR11DA PLUMBING CODE DRAWN WATER CL05ET5 BUSINESS 1/ 25 For first 50 44 PERSONS = 2 2 WATER CLOSETS PROJECT NUMBER 1/ 50 remainder DRAWING NUMBER LAVATORIES BUSINESS 1/ 40 for first 80 44 PERSONS = 2 2 LAVATORIES I / 80 remainder DRINKING FOUNTAINS BUSINESS 1 / 100 1 EXISTING SERVICE SINK BUSINESS I 1 EXISTING I EXIST. FIRE I 0 OFFICE STORAGER ORISER 1000 PARTS/ TEST EQUIP 105 I STORAGE 108 16 FT TRAVEL DISTANCE -----—-----——— — — — — —— UNISEX ,' �' TOILET PRODUCTION Ilm I BILLING LOBBY I III T JAN •1 112 EXIST. p-------o-------q TOILET 113 RECEIVING Io- p I n FT TRAVEL DISTANCE Ii OFFICE 114 I II I I SHIPPING I im2 RECEPTION R5 L _I ENTRY 101 a JLb- FIRST FLOOR LIFE SAFETY PLAN SCALE: 1/8"=1'-0" SYMBOL LEGEND FE FIRE EXTINGUISHER BRACKET MOUNTED ON WALL (4-A:(b0:5:C, 10 LB TYPE). TOP OF EXTINGUISHER 50' AFF. EXTINGUISHERS IN KITCHENS ARE CLASS K. FEC FIRE EXTINGUISHER IN RECESSED CABINET. .0 (4-A:(00:5:C, 10 LB TYPE) CENTER OF CA515ET AT 42' AFF. 164 EXIT DISCHARGE POINT AND NUMBER OF OCCUPANTS SERVED 60 FT TRAVEL — — — — —W— EXIT PATHS AND TRAVEL DISTANCES EQUIPMENT 138 .ROOM NAME 4 NUMBER TOP SIDE OF NEW LAY -IN CLG TOP OF I EX TOILET 14 FT TRAVEL DISTANCE EXISTING MEZZANINE 201 i I II MEZZANINE LIFE SAFETY PLAN SCALE: 1/8"=1'-0" CD c 0 .0 L m m 0 a� O a t:. Cr s A CL s. Nj wvi Wr"_o U W Ei O w LUOQa�� U a�Mo U I—+ ct �D rVT1, ct DRAWN CHECKED' RSC NBB PROJECT NUMBER 1716 DRAWING NUMBER -A-101 DATE Q2-23-18 11 BRACE WALL TO METAL DECK OR STRUCTURAL MEMBER ABOVE W/ 3 5/a' METAL STUDS 9 48' OC, ANG OR W/ POWER ACT ED FASTENER (HILTI .138 C IR EQ) %4 LONG (TYP) SUSPENDED ACOUSTICAL ` TILE CEILING NSUL- SEE WALL TYPE r' I %a' GYP BD ON EA SIDE 3 5/8' METAL STUDS m 24' O.G. l : I FLOOR FINISH AND BASE } r SEE FINISH SCHEDULE POWER ACTUATED FASTENTER (HILTI .138 OR EQ) 3/4' LONG A 16' OC (TYP) NON RATED - GYP BD WALL -TYPICAL ACT CEILING 1 SCALE: 1 1/2" = 1'-0" L 6' 18 GA STUDS 9 24' OC SPANNINGBLKG WALL TO WALL OVER TOILET I I . GYP BD CEILING ON 2X8 I I METAL STUDS g 16' OC 5/a' GYP BD ON EA SIDE 3 5/8' 18 GA METAL STUDS 6 12' O.C. :; fFLOOR FINISH AND BASE SEE FINISH SCHEDULE POWER ACTUATED FASTENTER (HILTI .138 OR EQ) 3/4' LONG g 16' OC (TYP) NOT RATED - GYP BD TYP WALL SECTION GYP BD CEILING SCALE: 1 1/2" = 1'-0" FINISH KEY ■11■■■M■■■■ In ROOM FINISH SCHEDULE MENAA 2 ON DOOR SCHEDULE BASE DOOR N0. L,rr DOOR CEILING FRAME FIRE RATING DETAILS NOTES SIZE MAT. FINISH TYPE MAT. FINISH TYPE HEAD JAMB SILL TILE, SELECTED BY OWNER 2 TILE, SELECTED BY OWNER cz 0 B ACOUSTICAL TILE CLG SYSTEM, SELECTED BY OWNER ROOM NAME 3 TILE, SELECTED BY OWNER C 105 3 GYPSUM BOARD - EPDXY- COLOR TBD e GYPSUM BOARD - PAINT COLOR TBD 205 ROOM NUMBER FLOOR 5 C I A 3'-0' X 1'-0' WD/SOLID PAINT A WD PAINT 1 -- N1 J1 -- -- 104 .LLJ Ir I- Y-0' X 1'-0' WD/50LID PAINT A WD PAINT I -- N1 J1 -- -- 105 113 Y-0' X 1'-0' WD/SOLID PAINT A WD PAINT I -- H1 JI -- -- 109) ►�-� 3'-0' X 1'-0' WD/SOLID PAINT A WD PAINT i -- HI JI -- -- 107, ■NINE Y-0' X 1'-0' WD/SOLID PAINT A WD PAINT I -- Hl JI -- -- 10ei Y-0' X 1'-0' WD/SOLID PAINT A WD PAINT 1 -- Hl JI -- -- 10i) 3'-0' X 1'-0' WD/SOLID PAINT A WD PAINT 1 -- H1 J1 1716 III A- -102 Y-0' X 1'-0' WD/SOLID PAINT A WD PAINT 1 -- H1 J1 -- -- 112 111111111111111r� Y-0' X 1'-0' WD/SOLID PAINT I A WD PAINT 1 -- H1 J1 -- -- INE■.�,a.111MMM■�■■■�i i���■■ ■I r.0,311 I. 2. 3. 4_- EXCEPT AS SPECIFICALLY PERMITTED 5Y SECTION 1008.1.8, EGRESS DOORS SHALL 5E READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL EFFORT. HARDWARE 4 OPERATION SHALL BE PER OWNER'S STANDARDS AND MATCH STYLE AND FINISHES of EXISTING DOOR WHICH REMAINS. COMPLY WITH REQUIREMENTS OF FBC AND NFPA 101. 11 BRACE WALL TO METAL DECK OR STRUCTURAL MEMBER ABOVE W/ 3 5/a' METAL STUDS 9 48' OC, ANG OR W/ POWER ACT ED FASTENER (HILTI .138 C IR EQ) %4 LONG (TYP) SUSPENDED ACOUSTICAL ` TILE CEILING NSUL- SEE WALL TYPE r' I %a' GYP BD ON EA SIDE 3 5/8' METAL STUDS m 24' O.G. l : I FLOOR FINISH AND BASE } r SEE FINISH SCHEDULE POWER ACTUATED FASTENTER (HILTI .138 OR EQ) 3/4' LONG A 16' OC (TYP) NON RATED - GYP BD WALL -TYPICAL ACT CEILING 1 SCALE: 1 1/2" = 1'-0" L 6' 18 GA STUDS 9 24' OC SPANNINGBLKG WALL TO WALL OVER TOILET I I . GYP BD CEILING ON 2X8 I I METAL STUDS g 16' OC 5/a' GYP BD ON EA SIDE 3 5/8' 18 GA METAL STUDS 6 12' O.C. :; fFLOOR FINISH AND BASE SEE FINISH SCHEDULE POWER ACTUATED FASTENTER (HILTI .138 OR EQ) 3/4' LONG g 16' OC (TYP) NOT RATED - GYP BD TYP WALL SECTION GYP BD CEILING SCALE: 1 1/2" = 1'-0" FINISH KEY ■11■■■M■■■■ In ROOM FINISH SCHEDULE MENAA 2 ON - FLOOR BASE WALLS L,rr CEILING 1 EPDXY PAINT A WOOD - PAINTED, SELECTED BY OWNER 1 GYPSUM BOARD - NEW 4 EX- PAINT COLOR TBD ■■I ` A DECK 4 JOISTS - PAINT COLOR TBD 2 CARPET, SELECTED BY OWNER B TILE, SELECTED BY OWNER 2 TILE, SELECTED BY OWNER cz 0 B ACOUSTICAL TILE CLG SYSTEM, SELECTED BY OWNER ROOM NAME 3 TILE, SELECTED BY OWNER C 105 3 GYPSUM BOARD - EPDXY- COLOR TBD e GYPSUM BOARD - PAINT COLOR TBD 205 ROOM NUMBER FLOOR 5 C I A 4 1■■11■1 D IM%/I■M■■MM■■■■■■Eli 4 ;n BILLING 1ID4 � In D _ BASE CEILING WALLS 1. EXISTING CONC SLAB TO BE CLEANED AND SEALED TO REMAIN CONCRETE. III I A I A .LLJ Ir I- 2. EXISTING GYP BD WALLS THAT REMAIN ARE TO BE REPAIRED AS REQUIRED FOR LEVEL 4 FINISH IN PREPARATION FOR PAINTING. CLs 3. IN ill I A I A EX SIZE AS SCHED SIZE AS SCNi=p r DOOR TYPES FRAME TYPES SCALE: 1/4" = 1'- 0" SCALE: 1/4" = 1'- 0" H1 5/8' GYP BD SEALANT CONT EA SIDE (TYP) WD FRAME 4 TRIM DOOR 4 FRAME AS SCHEDULED SEE PLANS FOR STUD SIZES 5/8' GYP BD SEALANT CONT EA SIDE (TYP) WD FRAME 4 TRIM DOOR 4 FRAME AS SCHEDULED NOTE: ALL DIMENSIONS LOCATING FIXTURES SHALL BE TAKEN FROM FACE OF FINISH WALL 48' x 30' MIN CLEAR LAV FLOOR SPACE (TYP) FRAMED GLASS MIRROR �5' J (18'X30' MOUNT 40 -AFF 08-290 SERIES r5 - UNISEX36' GRAB BAR, "852 SERIES 1 ILET STANDARD FINISH 6-0'-DIA---- MIN -0'-DIA----MIN TURNING t 60' x 59' MIN CLEAR f SPACE ' WATER CLOSET FLOOR ' SPACE (TYP) t 4 t ' 42' GRAB BAR *852 SERIES STANDARD FINISH ENLARGED UNI - S EX r,,_`*�.RESTROO.M SCALE: 1/4"=P-0" TOP SIDE OF NEW LAY -IN CLG EX A.Iowa MEZZANM EXISTINGIIIAIIIAI TOP OF EX TOILET Mom ■■ ■11■■■M■■■■ In 1111111112. MEMO MENAA 2 ON - L,rr U c OFFICE ;n STORAGE 106 - 1m7 z a l a z A l a 000 PARTS/ N 0 ■■I ` ■11■■c-0 E■■11111100. ■ „ „, STORACxE cz 0 � 108 ims I A I A 105 r _ , ` UNISEX 109 , TOILET i- 1■� PRODUCTION 1■■11■1 IM%/I■M■■MM■■■■■■Eli 0 ;n BILLING 1ID4 � In 111 EX _ z a I a LOBBY III I A I A .LLJ Ir I- - –� — — — — — — 112 — 6'-6' '"_� CLs JAN IN ill I A I A EX EXIST. RECEIVING I I 113 s 103 i I z A i A 103 OI a l A n I OOFFICE i 114 v' ` C*1 vl U o U 7 1■■��E% ►�-� 1�-1 aj s w Z IIIIM ■M 0 1100 � ■NINE �■�� W M H O oc � w73 O1 N r_l C/1 0 DRAWN CHECKED RSC NBB PROJECT NUMBER 1716 DRAWING NUMBER A- -102 DATE 02-23-18 1■DD III 111111111111111r� ON 1■� �1:��MIN ■111■sM■MM■1: mO�:�■■■■ INE■.�,a.111MMM■�■■■�i i���■■ ■I r.0,311 1■IN M■■M■MCMIN IM`on ■������■ 1 Nil IN ■■r■I■I 1111111IEMM 1■ ■11■■■■■/IME■1 ■mumm I■■m■ i■■ NONE IS p INN MEMIN O ■■■M■I ®� - 09111C01111111 FBI 1■ ■11 IM■■M■■■� ■■■■■■■■■■I loom NJ 1111111104101111111 I10000011110MMMM 1■■E■EM■EIS go, IMMV4 MEN \\ ■■0■■D■ ■■■� �■■■■■■� \ ■� ■ O �M■ ■ I ■ i ■■■■��■■■: 1■■t�W■■■1 ■■M■■■■M!-■■■ ■■IINEK- �■■■■■E■EI , =1311111011 M■■r i■■N■NE 10 Erma., ■■■■i■■■■■1 M■ ON ■■ ►. in ■11■E■■■■■■1 No ■■■■I■ l■■■E■■■MI REFLECTED CEILING PLAN SCALE: 1/8"=1'-0" SHIPPING I IID2 I A I a RECEPTION 8�_4� 115 ENTRY r EX 101 EX I EX EX C PROPOSED FLOOR PLAN SCALE: 1/8"=1'-0" m >1 14'-0' 16'-7' 16'-0' EXIST. FIRE RISER 0 CL U c OFFICE ;n STORAGE 106 - 1m7 z a l a z A l a 000 PARTS/ N 0 TEST EQUIP ih IID5 STORACxE cz 0 � 108 ims I A I A 105 r _ , ` UNISEX 109 , TOILET i- PRODUCTION 1 �- o 110 I a I a 0 ;n BILLING 1ID4 � In 111 EX _ z a I a LOBBY III I A I A .LLJ Ir I- - –� — — — — — — 112 — 6'-6' CLs JAN ill I A I A EX EXIST. RECEIVING I I 113 s 103 i I z A i A 103 OI a l A n I OOFFICE i 114 v' ` C*1 vl U o U 7 EX SHIPPING I IID2 I A I a RECEPTION 8�_4� 115 ENTRY r EX 101 EX I EX EX C PROPOSED FLOOR PLAN SCALE: 1/8"=1'-0" m >1 0 CL U c N 0 a� cz 0 0 .LLJ Ir I- CLs p s v1 v' ` C*1 vl U o U 7 ►�-� 1�-1 aj s w Z w�I U W M H O oc � w73 O1 N r_l C/1 0 DRAWN CHECKED RSC NBB PROJECT NUMBER 1716 DRAWING NUMBER A- -102 DATE 02-23-18 Moo mew me 0 1 GENERAL NOTES LEGEND SUPPLY DIFFUSER. (4 -WAY) QX REFERENCE NOTES SA SUPPLY AIR 1. INSTALL EQUIPMENT AND MATERIALS IN COMPLIANCE WITH MANUFACTURER'S MINIMUM CLEARANCE RETURN OR OUTDOOR AIR GRILLE O REFERENCE NOTE - MULTI -DISCIPLINE SHEETS SF SUPPLY FAN REQUIREMENTS AND RECOMMENDATIONS. SDT SMOKE DETECTOR_41— FLOW DIRECTION 2. COMPLY WITH THE LATEST EDITIONS OF NFPA AND THE LATEST ADOPTED EDITION FLORIDA BUILDING CODE � EXHAUST GRILLE SD SUPPLY DIFFUSER (MECHANICAL, PLUMBING AND GAS). INDICATES POINT OF CONNECTION BETWEEN NEW SDMP SMOKE DAMPER 3. ALL MATERIALS SHALL FIT THE SPACE AVAILABLE. VERIFY DIMENSIONS AND CLEARANCES ON BUILDING ® AND EXISTING. SQ.FT. SQUARE FOOT PLANS PRIOR TO COMMENCING WORK. SUPPLY DUCT UP SECTION RECTANGULAR SR SUPPLY REGISTER (RECTANGULAR) ® POINT OF DISCONNECT STR STARTER 4. CONTRACTOR IS RESPONSIBLE FOR TESTING AND BALANCING OF AIR SYSTEMS IN ACCORDANCE WITH AABC GUIDELINES. A TEST AND BALANCE REPORT SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL SWSI SINGLE WIDTH, SINGLE INLET RETURN DUCT UP SECTION (RECTANGULAR) CWS CONDENSER WATER SUPPLY PIPING. SZ SINGLE ZONE 5. PROVIDE 45 DEGREE BRANCH TAKE -OFF PER SMACNA FIG. 2-8 ON ALL RECTANGULAR DUCT TAKE -OFFS. TEFC TOTALLY ENCLOSED FAN COOLEDCWR CONDENSER WATER RETURN PIPING. 6. PROVIDE AND INSTALL DUCT MOUNTED HINGED ACCESS DOORS FOR ALL SMOKE AND/OR FIRE DAMPERS, TEMP TEMPERATURE NOT OTHERWISE ACCESSIBLE. EXHAUST DUCT UP SECTION (RECTANGULAR) TG TRANSFER GRILLE !�BCWS BUILDING CONDENSER WATER SUPPLY PIPING. T/0 .TRANSFER OPENING ABOVE CEILING 7. CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF EACH PIECE OF EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING AND SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO OR SUPPLY DUCT DOWN SECTION (RECTANGULAR) T'STAT THERMOSTAT INSTALLING EQUIPMENT AND MATERIALS. TYP TYPICAL BCWR BUILDING CONDENSER WATER RETURN PIPING. VFDC VARIABLE FREQUENCY DRIVE 8. COORDINATE ALL HVAC SYSTEM DRAWINGS WITH EXISTING/NEW TRUSS TO AVOID INTERFERENCE BETWEEN CONTROLLER MECHANICAL SYSTEMS AND ROOF STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RETURN DUCT DOWN SECTION (RECTANGULAR) CHWS CHILLED WATER SUPPLY PIPING. ASSOCIATED WITH TRUSS INTERFERENCE THAT OCCURS IN THE FIELD DURING CONSTRUCTION. COORDINATE VAV VARIABLE AIR VOLUME IN ADVANCE. DUCT SIZES MAY BE REVISED TO FIT TRUSS SYSTEM SO LONG AS THE EQUIVALENT INSIDE VS VARIABLE SPEED CROSS SECTIONAL AREA IS NOT DECREASED. CHWR CHILLED WATER RETURN PIPING. EXHAUST DUCT DOWN SECTION (RECTANGULAR) W WATTS 9. GAUGES AND CONSTRUCTION FOR DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA'S HVAC W/ WITH DUCT CONSTRUCTION STANDARDS, HWS HEATING WATER SUPPLY PIPING. W/0 WITHOUT 10. TRANSITION RECTANGULAR DUCTWORK ON BOTTOM AND SIDES. MAINTAIN TOP OF DUCTWORK LEVEL AND SUPPLY DUCT UP SECTION (ROUND). WB WETBULB HIGH AS POSSIBLE. FLEXIBLE DUCT RUN -OUTS TO CEILING DIFFUSERS SHALL BE AS STRAIGHT AS ZD ZONE DAMPER POSSIBLE AND FREE OF SAGS & KINKS. FLEX DUCT SHALL BE THE SAME SIZE AS THE DIFFUSER NECK IT HWR HEATING WATER RETURN PIPING. SERVES. SUPPLY DUCT DOWN SECTION (ROUND). 11. ALL DUCT TRANSITIONS FROM SQUARE TO ROUND SHALL BE SMOOTH SQUARE TO ROUND TRANSITIONS. CD CONDENSATE DRAIN PIPING. SPIN -IN FITTINGS AT THE END OF CAPPED DUCTS ARE NOT ACCEPTABLE. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS. LINEAR SLOT DIFFUSER R REFRIGERANT PIPING 12. THE CONTRACTOR SHALL FULFILL ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SHALL COMPLETE THE WORK SHOWN ON THESE DRAWINGS. ALL SYSTEMS SHALL BE FINISHED, TESTED AND BALANCED, (� EXISTING LINEARSLOT DIFFUSER (LIGHT LINETYPE) FS FLOW SENSOR. ADJUSTED, AND PROVEN TO BE FULLY OPERATIONAL AND USEABLE. 13. ADJUST ALL DIFFUSERS IN CORRIDORS OR WITHIN THREE (3) FEET OF A WALL TO PROVIDE 2 -WAY OR �Z RECTANGULAR DUCTWORK WITH TAKE -OFF, BALANCING SP 3 -WAY BLOW AWAY FROM OR PARALLEL TO WALLS. ALL DIFFUSERS SHALL HAVE 4 -WAY BLOW UNLESS DAMPER AND INSULATED FLEXIBLE ROUND DUCT. SAME STATIC PRESSURE TRANSMITTER ASSEMBLY. NOTED OTHERWISE. A B SIZE AS DIFFUSER INLET UNLESS NOTED OTHERWISE. FIRST DIMENSION IS THAT OF SIDE SHOWN. 14. PORTIONS OF DUCTWORK VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. A ROUND DUCTWORK. 15. ALL DAMPERS IN AND ABOVE CEILING SHALL BE ACCESSIBLE. CONTRACTOR SHALL COORDINATE ALL CONICAL FITTING WITH DAMPER ON BRANCH L RECTANGULAR BRANCH DUCT CONNECTION. CONNECTION TO RECTANGULAR MAIN L=11/0, (PROVIDE BALANCING DAMPER AT ALL ACCESS PANELS CEILINGS OR WALLS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND INTERIOR (VE DAMPER IN LOW PRESSURE DUCTWORK ONLY). . 4' BRANCH CONNECTIONS DRAWINGS FOR PROPER (PROVIDE MINw OPER LOCATION. ) 16. MOUNT THERMOSTATS WHERE INDICATED ON PLANS 48" A.F.F. UNLESS NOTED OTHERWISE. IN HANDICAPPED EXISTING DUCTWORK TO REMAIN (LIGHT LINETYPE) i �— -- TEE (PLAN, UP, DOWN). ACCESSIBLE AREAS, MOUNT CONTROLS AT 48" ABOVE FINISHED FLOOR. 17. COORDINATE DUCTWORK AND PIPING WITH PLUMBING, FIRE PROTECTION AND ELECTRICAL MAKE OFFSETSR —O ELBOW (PLAN, UP, DOWN). AND TRANSITIONS TO COORDINATE WITH OTHER TRADES WITHOUT ANY ADDITIONAL EXPENSE TO THE DUCT OFFSETS UP (RISE) IN DIRECTION INDICATED. CONTRACT. 18. SEAL ALL TRANSVERSE JOINTS AND FITTINGS WITH DUCT SEALER. D DUCT OFFSETS DOWN (DROP) IN DIRECTION INDICATED. VALVE. 19. TRAP AND ROUTE CONDENSATE DRAINS LINES, FULL SIZE OF UNIT CONNECTION, AS INDICATED. SLOPE TWO WAY MOTORIZED CONTROL VALVE. 1/8" PER FOOT. OPPOSED BLADE VOLUME DAMPER (OBD). 20. ALTERNATE MANUFACTURERS AND MODELS WILL BE REVIEWED. THERE MAY BE ARCHITECTURAL, STRUCTURAL THREE WAY MOTORIZED CONTROL VALVE. AND ELECTRICAL CHANGES RESULTING FROM THE ALTERNATES. THE COST OF IMPLEMENTING AND ENGINEERING THESE CHANGES SHALL BE BORNE BY THE MECHANICAL SUBCONTRACTOR. MANUAL DAMPER 21. PIPE AND DUCT ROUTING SHOWN IS SCHEMATIC. PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS, PRESSURE REDUCING VALVE. INCLUDING DIVIDED DUCTS, REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES AS VIII ��]� FLOW CONTROL VALVE. ENCOUNTERED IN THE FIELD. FLEXIBLE DUCT CONNECTION. 22. COORDINATE CEILING MOUNTED AIR DEVICE LOCATION WITH REFLECTED CEILING PLAN AND OTHER TRADES. BALL VALVE FOR PIPING 2 -INCHES AND SMALLER, --I��— 23. ALL CONTROL WIRING AND CONDUIT SHALL COMPLY WITH NEC DIVISION 16 SPECIFICATIONS. FIRE DAMPER WITH ACCESS PANEL BUTTERFLY VALVE FOR PIPING 2-1/2 INCHES ANDLARGER. 24. PROVIDE MATERIALS WHICH HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED BUTTERFLY VALVE. RATING OF 50 OR LESS WHEN TESTED IN ACCORD WITH ASTM E84. COMBINATION FIRE/SMOKE DAMPER WITH ACCESS PANEL 25. SLEEVE AND FIRE STOP PENETRATIONS THROUGH FIRE RATED SYSTEMS TO MAINTAIN RATING OF SYSTEM. CHECK VALVE. USE MINIMUM GALVANIZED STEEL GAUGE DUCT AS REQUIRED TO MAINTAIN RATING OF SYSTEM. 26. THE TABC SHA EXISTING DUCTWORK TO BE REMOVED (DASHED LINETYPE) STRAINER. - - - LL BE EMPLOYED DIRECTLY BY THE GENERAL CONTRACTOR WHO SHALL BE SOLELY RESPONSIBLE FOR ITS PERFORMANCE AND THE TIMELY SCHEDULE OF ITS OPERATION. DUCT MOUNTED SMOKE DETECTOR PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY BALANCE VALVE WITH INTEGRAL TAPS FOR CONNECTION 27. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH MECHANICAL CONTRACTOR. REFER TO SPECIFICATIONS FOR OF DIFFERENTIAL PRESSURE METER. VALVE SHALL OF THE DUCT SHALL BE IDENTIFIED ON A PERMENANT LABEL OR TAG. THE LABEL OR TAG SHALL BE CONTROL REQUIREMENTS. HAVE NAMEPLATE INDICATING WATER FLOW RATE VERSUS LOCATED WITHIN 6 FEET OF THE EXHAUST DUCT CONNECTION. -10AIR DEVICE TAG VALVE PRESSURE DROP. 0 28. CONTRACTOR TO ORDER ALL FIRE/SMOKE DAMPERS WITH INTEGRAL SMOKE DETECTORS AND END STOP MARK -CFM AUTOMATIC FLOW CONTROL VALVE WITH INTEGRAL INDICATOR OPTIONS. VERIFY VOLTAGE WITH ELECTRICAL DRAWINGS. IF BUILDING IS EQUIPPED WITH FIRE A TEMPERATURE AND PRESSURE TEST PORTS. ALARM SYSTEM ALL FIRE/SMOKE DAMPERS WILL BE CONNECTED TO BUILDING FIRE ALARM SYSTEM. SIDEWALL TRANSFER GRILLE —� UNION. SIDEWALL SUPPLY REGISTER VENTURI FLOW METER. SIDEWALL RETURN GRILLE OR OUTSIDE AIR LOUVER PRESSURE AND/OR TEMPERATURE PORT SIDEWALL EXHAUST GRILLE THERMOMETER. -TS WALL MOUNTED DDC TEMPERATURE SENSOR MOUNT 48" ABOVE FINISHED FLOOR. PRESSURE GAUGE WITH GAUGE COCK. O WALL MOUNTED THERMOSTAT FLEXIBLE CONNECTION. MOUNT 48 ABOVE FINISHED FLOOR. © WALL MOUNTED CO SENSOR PRESSURE RELIEF VALVE. MOUNT 480 ABOVE FINISHED FLOOR. O WALL MOUNTED DDC HUMIDITY SENSOR R MOTORIZED ACTUATOR H MOUNT 48" ABOVE FINISHED FLOOR. OS WALL MOUNTED HUMIDISTAT SENSOR OPENING IN WALL ABOVE CEILING. MOUNT 48" ABOVE FINISHED FLOOR. je A PHOTO DETAIL OR SECTION IDENTIFICATION TARGET AH EQUIPMENT B A = DETAIL NUMBER. TYPE EQUIPMENT TAG B = SHEET NUMBER ON WHICH DETAIL IS LOCATED. MARK �®RD RADIATION DAMPER INSTALLED .1" DOOR UNDER CUT. ARROW INDICATES DIRECTION IN AIR DEVICE UC OF FLOW RD 'RADIATION DAMPER INSTALLED NOTE: IN DUCT. NOTE: GENERAL NOTES ON THIS MECHANICAL SHEET ARE FOR SYMBOLS SHOWN ON THIS MECHANICAL LEGEND ARE FOR GENERAL REFERENCE PURPOSES ONLY. ALL OF THESE ELBOW WITH TURNING VANES REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLS NOTES MAY NOT BE USED FOR THIS PROJECT. MAY NOT BE USED FOR THIS PROJECT. m c 0 U v7 a.� 0 m 0 > m U '. o- GI O N c o c a W J ziE ° "tJ Nelson WankensMp, AIA P••, V1 Q ® W � o UN � u xM O ago�� o a Mo ct U Ct U N �M 7� vD Q aj H P1 G!J 4_5 � �� 0 a z ry, DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER m 001 DATE - 02-23-18 ABV ABOVE ADJ ADJUSTABLE _ AF AIRFOIL AFF ABOVE FINISHED FLOOR AC AIR CONDITIONER ACU AIR CONDITIONING UNIT AHU AIR HANDLING UNIT AP ACCESS PANEL BAS BUILDING AUTOMATION SYSTEM BI BACKWARD INCLINE BLDG BUILDING BHP BRAKE HORSEPOWER BTUH BRITISH THERMAL UNIT PER HOUR CD CONDENSATE DRAIN CFM CUBIC FEET PER MINUTE CLG CEILING CW CHILLED WATER CWR CHILLED WATER RETURN CWS CHILLED WATER SUPPLY CONC CONCRETE COND CONDENSATE CONT : CONTINUOUS CO CARBON MONOXIDE COP COEFFICIENT OF PERFORMANCE CU CONDENSING UNIT DB DRYBULB DWDI DOUBLE WIDTH, DOUBLE INLET DWGS DRAWINGS DX DIRECT EXPANSION EF EXHAUST FAN EXH EXHAUST EA EACH EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO ELECT ELECTRICAL ENT ENTERING EQ EQUAL ER EXHAUST REGISTER EWT ENTERING WATER TEMPERATURE FC FORWARD CURVED FCU FAN COIL UNIT FD FIRE DAMPER FIL FLOOR FLEX FLEXIBLE CONNECTOR OR DUCT FPM FEET PER MINUTE F/S COMBINATION FIRE AND SMOKE DAMPER FT. H2O FEET WATER GAUGE F DEGREES FAHRENHEIT GA GAUGE GAL GALLON GALV GALVANIZED GPM GALLONS PER MINUTE HP HORSEPOWER HTWR HIGH TEMPERATURE HOT WATER RETURN HTWS HIGH TEMPERATURE HOT WATER SUPPLY HW HOT WATER HWR HOT WATER RETURN HWS HOT WATER SUPPLY HVAC HEATING VENTILATING AND AIR CONDITIONING HV HEATING AND VENTILATING IN.WG INCHES WATER GAGE KW KILOWATTS LAT LEAVING AIR TEMPERATURE LD LINEAR DIFFUSER LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MBH 1000 X BTUH MIN MINIMUM MVD MANUAL VOLUME DAMPER MZ MULTI -ZONE N.T.S. NOT TO SCALE OA OUTSIDE AIR OBMVD OPPOSED BLADE MANUAL VOLUME DAMPER OPD OPEN DRIP PROOF PROP PROPELLER PCR PRE -CONDITIONED AIR SYSTEM RETURN WATER PCS PERCENT PD PRESSURE DROP PERF. PL. PERFORATED PLATE PLBG PLUMBING PSIA POUNDS PER SQUARE INCH ABSOLUTE PSIG POUNDS PER SQUARE INCH GAUGE RA RETURN AIR RD RADIATION DAMPER REG REGISTER REQ'D REQUIRED RG RETURN AIR GRILLE RH RELATIVE HUMIDITY RPM REVOLUTIONS PER MINUTE RR RETURN AIR REGISTER RTU ROOFTOP UNIT GENERAL NOTES LEGEND SUPPLY DIFFUSER. (4 -WAY) QX REFERENCE NOTES SA SUPPLY AIR 1. INSTALL EQUIPMENT AND MATERIALS IN COMPLIANCE WITH MANUFACTURER'S MINIMUM CLEARANCE RETURN OR OUTDOOR AIR GRILLE O REFERENCE NOTE - MULTI -DISCIPLINE SHEETS SF SUPPLY FAN REQUIREMENTS AND RECOMMENDATIONS. SDT SMOKE DETECTOR_41— FLOW DIRECTION 2. COMPLY WITH THE LATEST EDITIONS OF NFPA AND THE LATEST ADOPTED EDITION FLORIDA BUILDING CODE � EXHAUST GRILLE SD SUPPLY DIFFUSER (MECHANICAL, PLUMBING AND GAS). INDICATES POINT OF CONNECTION BETWEEN NEW SDMP SMOKE DAMPER 3. ALL MATERIALS SHALL FIT THE SPACE AVAILABLE. VERIFY DIMENSIONS AND CLEARANCES ON BUILDING ® AND EXISTING. SQ.FT. SQUARE FOOT PLANS PRIOR TO COMMENCING WORK. SUPPLY DUCT UP SECTION RECTANGULAR SR SUPPLY REGISTER (RECTANGULAR) ® POINT OF DISCONNECT STR STARTER 4. CONTRACTOR IS RESPONSIBLE FOR TESTING AND BALANCING OF AIR SYSTEMS IN ACCORDANCE WITH AABC GUIDELINES. A TEST AND BALANCE REPORT SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL SWSI SINGLE WIDTH, SINGLE INLET RETURN DUCT UP SECTION (RECTANGULAR) CWS CONDENSER WATER SUPPLY PIPING. SZ SINGLE ZONE 5. PROVIDE 45 DEGREE BRANCH TAKE -OFF PER SMACNA FIG. 2-8 ON ALL RECTANGULAR DUCT TAKE -OFFS. TEFC TOTALLY ENCLOSED FAN COOLEDCWR CONDENSER WATER RETURN PIPING. 6. PROVIDE AND INSTALL DUCT MOUNTED HINGED ACCESS DOORS FOR ALL SMOKE AND/OR FIRE DAMPERS, TEMP TEMPERATURE NOT OTHERWISE ACCESSIBLE. EXHAUST DUCT UP SECTION (RECTANGULAR) TG TRANSFER GRILLE !�BCWS BUILDING CONDENSER WATER SUPPLY PIPING. T/0 .TRANSFER OPENING ABOVE CEILING 7. CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF EACH PIECE OF EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING AND SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO OR SUPPLY DUCT DOWN SECTION (RECTANGULAR) T'STAT THERMOSTAT INSTALLING EQUIPMENT AND MATERIALS. TYP TYPICAL BCWR BUILDING CONDENSER WATER RETURN PIPING. VFDC VARIABLE FREQUENCY DRIVE 8. COORDINATE ALL HVAC SYSTEM DRAWINGS WITH EXISTING/NEW TRUSS TO AVOID INTERFERENCE BETWEEN CONTROLLER MECHANICAL SYSTEMS AND ROOF STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RETURN DUCT DOWN SECTION (RECTANGULAR) CHWS CHILLED WATER SUPPLY PIPING. ASSOCIATED WITH TRUSS INTERFERENCE THAT OCCURS IN THE FIELD DURING CONSTRUCTION. COORDINATE VAV VARIABLE AIR VOLUME IN ADVANCE. DUCT SIZES MAY BE REVISED TO FIT TRUSS SYSTEM SO LONG AS THE EQUIVALENT INSIDE VS VARIABLE SPEED CROSS SECTIONAL AREA IS NOT DECREASED. CHWR CHILLED WATER RETURN PIPING. EXHAUST DUCT DOWN SECTION (RECTANGULAR) W WATTS 9. GAUGES AND CONSTRUCTION FOR DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA'S HVAC W/ WITH DUCT CONSTRUCTION STANDARDS, HWS HEATING WATER SUPPLY PIPING. W/0 WITHOUT 10. TRANSITION RECTANGULAR DUCTWORK ON BOTTOM AND SIDES. MAINTAIN TOP OF DUCTWORK LEVEL AND SUPPLY DUCT UP SECTION (ROUND). WB WETBULB HIGH AS POSSIBLE. FLEXIBLE DUCT RUN -OUTS TO CEILING DIFFUSERS SHALL BE AS STRAIGHT AS ZD ZONE DAMPER POSSIBLE AND FREE OF SAGS & KINKS. FLEX DUCT SHALL BE THE SAME SIZE AS THE DIFFUSER NECK IT HWR HEATING WATER RETURN PIPING. SERVES. SUPPLY DUCT DOWN SECTION (ROUND). 11. ALL DUCT TRANSITIONS FROM SQUARE TO ROUND SHALL BE SMOOTH SQUARE TO ROUND TRANSITIONS. CD CONDENSATE DRAIN PIPING. SPIN -IN FITTINGS AT THE END OF CAPPED DUCTS ARE NOT ACCEPTABLE. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS. LINEAR SLOT DIFFUSER R REFRIGERANT PIPING 12. THE CONTRACTOR SHALL FULFILL ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SHALL COMPLETE THE WORK SHOWN ON THESE DRAWINGS. ALL SYSTEMS SHALL BE FINISHED, TESTED AND BALANCED, (� EXISTING LINEARSLOT DIFFUSER (LIGHT LINETYPE) FS FLOW SENSOR. ADJUSTED, AND PROVEN TO BE FULLY OPERATIONAL AND USEABLE. 13. ADJUST ALL DIFFUSERS IN CORRIDORS OR WITHIN THREE (3) FEET OF A WALL TO PROVIDE 2 -WAY OR �Z RECTANGULAR DUCTWORK WITH TAKE -OFF, BALANCING SP 3 -WAY BLOW AWAY FROM OR PARALLEL TO WALLS. ALL DIFFUSERS SHALL HAVE 4 -WAY BLOW UNLESS DAMPER AND INSULATED FLEXIBLE ROUND DUCT. SAME STATIC PRESSURE TRANSMITTER ASSEMBLY. NOTED OTHERWISE. A B SIZE AS DIFFUSER INLET UNLESS NOTED OTHERWISE. FIRST DIMENSION IS THAT OF SIDE SHOWN. 14. PORTIONS OF DUCTWORK VISIBLE THROUGH GRILLES AND REGISTERS IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. A ROUND DUCTWORK. 15. ALL DAMPERS IN AND ABOVE CEILING SHALL BE ACCESSIBLE. CONTRACTOR SHALL COORDINATE ALL CONICAL FITTING WITH DAMPER ON BRANCH L RECTANGULAR BRANCH DUCT CONNECTION. CONNECTION TO RECTANGULAR MAIN L=11/0, (PROVIDE BALANCING DAMPER AT ALL ACCESS PANELS CEILINGS OR WALLS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND INTERIOR (VE DAMPER IN LOW PRESSURE DUCTWORK ONLY). . 4' BRANCH CONNECTIONS DRAWINGS FOR PROPER (PROVIDE MINw OPER LOCATION. ) 16. MOUNT THERMOSTATS WHERE INDICATED ON PLANS 48" A.F.F. UNLESS NOTED OTHERWISE. IN HANDICAPPED EXISTING DUCTWORK TO REMAIN (LIGHT LINETYPE) i �— -- TEE (PLAN, UP, DOWN). ACCESSIBLE AREAS, MOUNT CONTROLS AT 48" ABOVE FINISHED FLOOR. 17. COORDINATE DUCTWORK AND PIPING WITH PLUMBING, FIRE PROTECTION AND ELECTRICAL MAKE OFFSETSR —O ELBOW (PLAN, UP, DOWN). AND TRANSITIONS TO COORDINATE WITH OTHER TRADES WITHOUT ANY ADDITIONAL EXPENSE TO THE DUCT OFFSETS UP (RISE) IN DIRECTION INDICATED. CONTRACT. 18. SEAL ALL TRANSVERSE JOINTS AND FITTINGS WITH DUCT SEALER. D DUCT OFFSETS DOWN (DROP) IN DIRECTION INDICATED. VALVE. 19. TRAP AND ROUTE CONDENSATE DRAINS LINES, FULL SIZE OF UNIT CONNECTION, AS INDICATED. SLOPE TWO WAY MOTORIZED CONTROL VALVE. 1/8" PER FOOT. OPPOSED BLADE VOLUME DAMPER (OBD). 20. ALTERNATE MANUFACTURERS AND MODELS WILL BE REVIEWED. THERE MAY BE ARCHITECTURAL, STRUCTURAL THREE WAY MOTORIZED CONTROL VALVE. AND ELECTRICAL CHANGES RESULTING FROM THE ALTERNATES. THE COST OF IMPLEMENTING AND ENGINEERING THESE CHANGES SHALL BE BORNE BY THE MECHANICAL SUBCONTRACTOR. MANUAL DAMPER 21. PIPE AND DUCT ROUTING SHOWN IS SCHEMATIC. PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS, PRESSURE REDUCING VALVE. INCLUDING DIVIDED DUCTS, REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES AS VIII ��]� FLOW CONTROL VALVE. ENCOUNTERED IN THE FIELD. FLEXIBLE DUCT CONNECTION. 22. COORDINATE CEILING MOUNTED AIR DEVICE LOCATION WITH REFLECTED CEILING PLAN AND OTHER TRADES. BALL VALVE FOR PIPING 2 -INCHES AND SMALLER, --I��— 23. ALL CONTROL WIRING AND CONDUIT SHALL COMPLY WITH NEC DIVISION 16 SPECIFICATIONS. FIRE DAMPER WITH ACCESS PANEL BUTTERFLY VALVE FOR PIPING 2-1/2 INCHES ANDLARGER. 24. PROVIDE MATERIALS WHICH HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED BUTTERFLY VALVE. RATING OF 50 OR LESS WHEN TESTED IN ACCORD WITH ASTM E84. COMBINATION FIRE/SMOKE DAMPER WITH ACCESS PANEL 25. SLEEVE AND FIRE STOP PENETRATIONS THROUGH FIRE RATED SYSTEMS TO MAINTAIN RATING OF SYSTEM. CHECK VALVE. USE MINIMUM GALVANIZED STEEL GAUGE DUCT AS REQUIRED TO MAINTAIN RATING OF SYSTEM. 26. THE TABC SHA EXISTING DUCTWORK TO BE REMOVED (DASHED LINETYPE) STRAINER. - - - LL BE EMPLOYED DIRECTLY BY THE GENERAL CONTRACTOR WHO SHALL BE SOLELY RESPONSIBLE FOR ITS PERFORMANCE AND THE TIMELY SCHEDULE OF ITS OPERATION. DUCT MOUNTED SMOKE DETECTOR PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY BALANCE VALVE WITH INTEGRAL TAPS FOR CONNECTION 27. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH MECHANICAL CONTRACTOR. REFER TO SPECIFICATIONS FOR OF DIFFERENTIAL PRESSURE METER. VALVE SHALL OF THE DUCT SHALL BE IDENTIFIED ON A PERMENANT LABEL OR TAG. THE LABEL OR TAG SHALL BE CONTROL REQUIREMENTS. HAVE NAMEPLATE INDICATING WATER FLOW RATE VERSUS LOCATED WITHIN 6 FEET OF THE EXHAUST DUCT CONNECTION. -10AIR DEVICE TAG VALVE PRESSURE DROP. 0 28. CONTRACTOR TO ORDER ALL FIRE/SMOKE DAMPERS WITH INTEGRAL SMOKE DETECTORS AND END STOP MARK -CFM AUTOMATIC FLOW CONTROL VALVE WITH INTEGRAL INDICATOR OPTIONS. VERIFY VOLTAGE WITH ELECTRICAL DRAWINGS. IF BUILDING IS EQUIPPED WITH FIRE A TEMPERATURE AND PRESSURE TEST PORTS. ALARM SYSTEM ALL FIRE/SMOKE DAMPERS WILL BE CONNECTED TO BUILDING FIRE ALARM SYSTEM. SIDEWALL TRANSFER GRILLE —� UNION. SIDEWALL SUPPLY REGISTER VENTURI FLOW METER. SIDEWALL RETURN GRILLE OR OUTSIDE AIR LOUVER PRESSURE AND/OR TEMPERATURE PORT SIDEWALL EXHAUST GRILLE THERMOMETER. -TS WALL MOUNTED DDC TEMPERATURE SENSOR MOUNT 48" ABOVE FINISHED FLOOR. PRESSURE GAUGE WITH GAUGE COCK. O WALL MOUNTED THERMOSTAT FLEXIBLE CONNECTION. MOUNT 48 ABOVE FINISHED FLOOR. © WALL MOUNTED CO SENSOR PRESSURE RELIEF VALVE. MOUNT 480 ABOVE FINISHED FLOOR. O WALL MOUNTED DDC HUMIDITY SENSOR R MOTORIZED ACTUATOR H MOUNT 48" ABOVE FINISHED FLOOR. OS WALL MOUNTED HUMIDISTAT SENSOR OPENING IN WALL ABOVE CEILING. MOUNT 48" ABOVE FINISHED FLOOR. je A PHOTO DETAIL OR SECTION IDENTIFICATION TARGET AH EQUIPMENT B A = DETAIL NUMBER. TYPE EQUIPMENT TAG B = SHEET NUMBER ON WHICH DETAIL IS LOCATED. MARK �®RD RADIATION DAMPER INSTALLED .1" DOOR UNDER CUT. ARROW INDICATES DIRECTION IN AIR DEVICE UC OF FLOW RD 'RADIATION DAMPER INSTALLED NOTE: IN DUCT. NOTE: GENERAL NOTES ON THIS MECHANICAL SHEET ARE FOR SYMBOLS SHOWN ON THIS MECHANICAL LEGEND ARE FOR GENERAL REFERENCE PURPOSES ONLY. ALL OF THESE ELBOW WITH TURNING VANES REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLS NOTES MAY NOT BE USED FOR THIS PROJECT. MAY NOT BE USED FOR THIS PROJECT. m c 0 U v7 a.� 0 m 0 > m U '. o- GI O N c o c a W J ziE ° "tJ Nelson WankensMp, AIA P••, V1 Q ® W � o UN � u xM O ago�� o a Mo ct U Ct U N �M 7� vD Q aj H P1 G!J 4_5 � �� 0 a z ry, DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER m 001 DATE - 02-23-18 Floor Plan - Mechanical SCALE: 1/8"=1'-0" Mezzanine Floor Plan - Mechanical SCALE: 1/8"=1'-0" REFERENCE NOTES: o O1 EXISTING ROOF TOP UNIT AND ALL CONNECTED DUCTWORK, SUPPLY/RETURN GRILLES AND THERMOSTAT TO REMAIN FOR FUTURE USE. O2 INSTALL NEW ROOF TOP UNIT PER DETAILS SHEET M-301. ROUTE FULL SIZE CONDENSATE LINES FROM ROOF TOP UNIT TO NEAREST ROOF DRAIN/SCUPPER. SUPPORT CONDENSATE LINES PER DETAIL SHEET M-401. DISTANCE BETWEEN SUPPORTS TO BE A MAXIMUM OF 4'-0". O3 ROUTE 6"0 GALVANIZED METAL EXHAUST DUCT FROM NEW EXHAUST FANS UP THROUGH ROOF AND TERMINATE WITH GOOSENECK WITH INTEGRAL BIRD SCREEN PER DETAIL SHEET M-401. EXHAUST TO BE AT LEAST 10'-0" AWAY FROM ANY OUTSIDE AIR INTAKE. ® PROVIDE NEW FULLY DIGITAL 7 DAY PROGRAMMABLE TYPE THERMOSTAT WITH AUTO CHANGE OVER AND AUTO SET BACK. MOUNT THERMOSTAT 4'-0" ABOVE FINISHED FLOOR. PROVIDE WITH CLEAR ACRYLIC LOCKING COVER. O5 PROVIDE REMOTE DAMPER FOR AIR DEVICE IN HARD CEILING. ® 30"x14" SUPPLY AND 36"x12" RETURN UP TO NEW ROOF TOP UNIT. TRANSITION AS REQUIRED. i .> e I "1 ds e b\p6?ney P: �.1* 124 [D c 0 a �i U U (D 0 m ro a� rz 0 U G) O N OM F W 7��WN C Ocm� °WW;� x o �~ Nelson Blankenship, AIA a�Qe w� o �N rHW� VCn U C W Wt U x Zx� w� u C) U ~ �^ ►-a Vi v i"r Ct U �D Q 4J o �O ;4 N O C'� '" a 0 w DRAWN CHECKED MJR./KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER M-201 DATE 02-23-18 4-#10 SELF 2"WIDE 18t nnni . n%ni niwvnv .i nwv I-- ("2ROOF TOP UNIT TIE -DOWN DETAIL NTS ELECTRICAL DISCONNECT PROVIDED MY MECHANICAL ROOF CURB -, CONTRACTOR ROUTE FULL SIZE CONDENSATE TO NEAREST ROOF DRAIN jTUU A TRANSITION AS REQUIRED FLEXIBLE CONNECTION (TYPICAL) SMOKE DETECTOR FOR AUTOMATIC SMOKE DETECTOR FOR AUTOMATIC ANGLE FRAMING (SEE STRUCTURAL) UNIT SHUT DOWN ON UNITS 2000 CF UNIT SHUT DOWN ON UNITS 2000 Cl OR LARGER (COORDINATE OR LARGER (COORDINATE WITH ELECTRICAL). WITH ELECTRICAL). RETURN AIR SUPPLY AIR 1" DUCT LINER FOR FIRST 10'-0" OF DUCT (TYPICAL ALL RTU'S) SEE MECHANICAL PLAN FOR DUCT SIZES 1 RTU INSTALLATION DETAIL -NTS - RTU 1/4" THICK RUBBER INSULATION PAD FULL CONTOUR OF CURB or FLASHING -CONTINUOUS CANT ROOFING MATERIAL ROOF DECK DECK II AIR BALANCE EXHAUST' EF -1 60 CFM EF -2 60 CFM EXHAUST TOTAL- 120 CFM MAKEUP AIR, RTU -1 605 CFM MAKEUP TOTAL:- 605 CFM BUILDING PRESSURE = +360 (WITH ALL FANS ACTIVATED) FLEX DUCT SCHEDULE CFM FLEX SIZE 0 - 100 6"0 101 - 200 8"0 201 - 400 10"0 401 - 600 12"0 601 - 900 14"0 901 - 1,300 16"0 1,300 - 1,700 18"0 OUTSIDE AIR CALCULATIONS CLASSIFICATION OCC. FACTOR ASHRAE 62 VALUES OCCUPANCY/ PER TABLE 6-1 1000 SQFT. (PERSONS) Rp Ra SPACE AREA (SQFT) SPACE OUTDOOR AIR LOAD REQUIRED (PERSONS) I Pz I (CFM) OUTDOOR AIR SUPPLIED (CFM) Az NOTES A LOUVERED FACE SUPPLY DIFFUSER 24"x24" SEE SCHED. ALUMINUM PRICE #ASCD 1., 2., 3., & 4. B LOUVERED FACE SUPPLY DIFFUSER BILLING 5 5 0.06 210 1 18 20 SHIP/RECEIVE 2 10 0.12 825 2 119 120 PRODUCTION 7 10 0.18 1,606 11 399 400 STORAGE 2 5 0.12 361 1 48 50 LOBBY 10 5 0.06 118 1 1 12 15 V/0 M.C.A. I M.O.C.P. TOTAL - - - 3,120* 16 596 605 NOTE: REQUIRED OUTDOOR VENTILATION AIR VALUES TAKEN FORM ASHRAE 62, TABLE 6-1. VENTILATION BREATHING ZONE FORMULA: Vbz = Rp * Pz + Ra * Az Pz = OCCUPANCY FACTOR * SPACE AREA *AREA DOES NOT INCLUDE RESTROOM. N '• ;� �r F Aclzdi E.' 54 ney P. 9124 m AIR DEVICE SCHEDULE FAN SCHEDULE MARK MARK DESCRIPTION FACE SIZE NECK MATERIAL MANUFACTURER & MODEL NO. NOTES A LOUVERED FACE SUPPLY DIFFUSER 24"x24" SEE SCHED. ALUMINUM PRICE #ASCD 1., 2., 3., & 4. B LOUVERED FACE SUPPLY DIFFUSER 12"x12" SEE SCHED. ALUMINUM PRICE #ASCD 1., 2., 3., & 4. C EGGCRATE RET./EXH. GRILLE (1/2"x1/2"0/2") 24"x24" SEE SCHED. ALUMINUM PRICE #80 1. & 2. NOTES: 0.25 24.3 1,250 1. COORIDINATE SURFACE FINISHES WITH ARCHITECTURAL DRAWINGS. GRILLES TO BE PAINTED SAME COLOR AS CEILING. - PANASONIC FV-08VF2 2. PROVIDE RAPID MOUNT FRAME FOR PLASTER AND SHEET ROCK CEILINGS. EF -2 (B/WB) JANITOR'S ROOM 3. SUPPLY COMPLETE FACTORY INSTALLED 1/2" THICK FOIL BACKED INSULATION. 0.25 24.3 4. PROVIDE REMOTE'DAMPERS FOR AIR DEVICE IN HARD CEILING. 120/10 0.8 - N '• ;� �r F Aclzdi E.' 54 ney P. 9124 m FAN SCHEDULE MARK AREA SERVED TYPE CFM T.S.P. HP/WATTS R.P.M. VOLTS/PH SONES WEIGHT MANUFACTURE. & MODEL NO. NOTES EF -1 EVAPORATOR SECTION UNISEX RESTROOM CABINET 60 0.25 24.3 1,250 120/10 0.8 - PANASONIC FV-08VF2 1. & 2. EF -2 (B/WB) JANITOR'S ROOM CABINET 60 0.25 24.3 1,250 120/10 0.8 - PANASONIC FV-08VF2 1. & 3. NOTES: 1. PROVIDE WITH VIBRATION ISOLATOR KIT, ROOF CURB AND DISCONNECT. 2. FAN TO BE CONTROLLED BY OCCUPANCY SENSOR IN ROOM. COORDINATE WITH ELECTRICAL DRAWINGS. 3. FAN TO BE CONTROLLED BY SWITCH LOCATED IN ROOM. COORDINATE WITH ELECTRICAL DRAWINGS. N '• ;� �r F Aclzdi E.' 54 ney P. 9124 m c 0 NEW ROOF TOP UNIT SCHEDULE C PLAN MARK 0 EVAPORATOR SECTION HEATER CONDENSER SECTION ELECTRICAL REQUIERMENTS WEIGHT (LBS.) EFF. (EER/SEER) MANUFACTURER AND MODEL NUMBER NOTES LOCATION SERVED SUPPLY AIRFLOW OUTSIDE AIRFLOW IR (CFM) (B/WB) (B/WB) TOTAL (MBH) G SENSIBLE (MBH) G IN. EOF WG. H.P. R.P.M. HEATER (KW) HEATER STAGES N0. COMPRESSOR COMPRESSOR ( R A NO. CO FANS ER CONDENSER FAN FLA V/0 M.C.A. I M.O.C.P. O Uy c m< c o^ LL] � 1Nn�N 3 m <fPQ f C Q m 3� RTU -1 BENNER LASER 4,000 - 80.0/67.0 57.7/57.2 1 124.10 1 96.20 0.8 1 4.7 1 871 1 12.0 1 1 2 15.6/15.9 1 2 1 1.5 1 208/30 1 61.0 1 70 1 977 1 11.3/- CARRIER 50TC-D12-5 1. & 2. NOTES: 1. PROVIDE COMPLETE WITH NON-FUSED DISCONNECT SWITCH (PROVIDED BY DIVISION 16), ROOF CURB, THRU THE BASE ELECTRICAL CONNECTION AND UNIT MOUNTED POWERED SERVICE RECEPTACLE. ROUTE FULL SIZE CONDENSATE TO NEAREST ROOF DRAIN. 2. PROVIDE MOTORIZED OUTSIDE AIR DAMPER. OUTSIDE AIR DAMPER SHALL CLOSE WHEN EVAPORATOR FAN MOTOR IS OFF. � U N '• ;� �r F Aclzdi E.' 54 ney P. 9124 m c 0 C 0 N N 0 0 O Uy c m< c o^ LL] � 1Nn�N 3 m <fPQ f C Q m 3� 0 Nelson Blankenship, AIA f. ,.. [�W� UN o Y � U W � o U W�Q� Qw zUC) Qa°� U P ct U ct � � U HM o Q O • r-� ct rz' N ctQ UD � � N U X11 DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER MV 301 DATE 02-23-18 (UNIT PRESSURE + 2" ) 2" NOTES : 1. CONDENSATE DRAIN SHALL BE PIPED FULL SIZE OF UNIT CONNECTION. 2. CONDENSATE LINES SHALL BE INSTALLED WITH ADEQUATE PITCH TO ENSURE POSITIVE DRAINAGE OF ACCUMILATED CONDENSATE. 3. TRAP CONDENSATE AND DISCHARGE PER PLAN. 9� CONDENSATE DRAIN DETAIL NTS Condensate Piping Supports I MAPA Model MS ­1 Spacing for MS -1 condensate support Copper PVC Pipe IPS 1-1/2" and smaller 5' 4' 2" 8' 4' 2" and larger 10' 4' Maximum recommended spacing on all rollersupp( Additional support recommended at each change o MAPA Products / 877-897-2371 Naples, Texas nvf+ f1^k111CAIQATC ❑IOC )RT. ADJUST RAIN SLOPES SECURE SACRIFICIAL SECTION OF MEMBRANE ROOF TO BOTTOM OF SUPPORT BASE USING APPROVED ADHESIVE PER MEMBRANE MATERIAL. SECURE SACRIFICIAL MEMBRANE AND SUPPORT BASE TO ROOF USING APPROVED ADHESIVE. NOTES: 1. SUPPORTS SHALL BE INSTALLED PER SCHEDULE AT LEFT. 5 CONDENSATE PIPE SUPPORT DETAIL NTS % SIDE TAKE -OFF FITTING - EQUAL TO FLEXMASTER STO (22 GA. MIN.) MAX. 15' TRANSITION 0.25 D } RECTANGULAR DUCT I ROUND DUCT 3 0 TO AIR ,r, a VALVE N r J 6 a 0 - VOLUME DAMPER N CONICAL FITTING WITH LOCKING TYPE VOLUME DAMPER. DAMPER AND DAMPER STAND-OFF EQUAL TO CROWN PRODUCTS COMPANY MODEL 3200 -DS. FLEX DUCT OR ROUND SHEET METAL DUCT. FLEX 3o DUCT MAX. 8'-0" LONG, USE CLAMP TO ATTACH LL. FLEX DUCTS AND SEAL AS PER SPECIFICATIONS, cr_ SUPPORT FLEX DUCT EVERY 3'-0" FROM STRUCTURE CL -3 DUCT CONNECTION DETAIL NTS ZDOVIDE BUG SCREEN C�l M z STORM COLLAR MINIMUM 8" HIGH PREFABRICATED ROOF CURB. _ROOF -_W, i REFER TO PLANS FOR SIZE GOOSENECK DETAIL STRUCTURE INTEGRAL BACKD DAMPER WITHIN TRANSITION EXHAUST FAN AS REQ'D SEE PLAN SECURE EXHAUST FANSIZE PER PLAN TO MFG. MOUNTING EXHAUST FAN BRACKET _\r_1 ca W U 0 7 NTS CEILING CEILING GRILLE TOILET AREA OR JAN. CLO. 5 CABINET FAN SUPPORT DETAIL 4 NTS NTS SEAL INSULATION JOINTS AND BREAKS IN VAPOR BARRIER WITH GLASS FABRIC AND MASTIC (NO TAPE ALLOWED) MAIN DUCT DRAWBAND ON OUTSIDE OF INSULATION AROUND JACKET - DRAWBAND ON FLEXIBLE DUCT (INNER SLEEVE) INSULATION AND JACKET i- FLEXIBLE DUCT BUTTERFLY DAMPER WITH LOCKING QUADRANT OPERATOR BELLMOUTH FITTING WATER BASE DUCT SEALER BETWEEN FLEXIBLE DUCT AND INSULATION AS SPECIFIE SHEETMETAL DUCT (APPLY SEALER TO BOTH SHEETMETAL AND INSIDE OF FLEX PRIOR TO ASSEMBLY) OVERLAP FULL DISTANCE OF NECK NOTES: 1. TYPICAL FOR: LOW PRESSURE AND HIGH PRESSURE CONNECTION TO MAIN DUCT, FAN TERMINAL UNITS, VARIABLE AIR VOLUME UNITS, AND DIFFUSERS. 2. DRAWBANDS SHALL BE EQUIVALENT TO PANDUIT PLT -H. 2 FLEXIBLE DUCT CONNECTION DETAIL NTS AIR DUCT DETECTOR AND AIR SAMPLING CHAMBER (MOUNT ON TOP IF SPACE REQUIRED DUCT WIDTH MOUNTING PLATE INTAKE TUBE NEOPRENE 0 0 0 0 0 o GASKET RETURN TUBE MOUNTING NUTS DUCT NOTES: 1. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS. 2. PROVIDE ACCESS DOOR AT SAMPLING TUBES. SMOKE DETECTOR DETAIL nr STRUCTURAL BAR JOIST J .ru�rn exn•nn 12" C, z a 12' 3" SCREWS 1" MIN NOTES 1. MAXIMUM SPACING BETWEEN HANGER LOCATIONS SHALL BE 8'-0" PER PAIR. 2. STRAPS SHALL BE MINIMUM 1 1/2" x 22 GAGE GALVANIZED STEEL 3. REFER TO SMACNA FOR ADDITIONAL REQUIREMENTS. ROUND SPIN -IN COLLAR MOUNT IN SIDE OF DUCT UNLESS DUCT SEALER AT SPIN SPECIFICALLY SHOWN OTHERWISE COLLAR CONNECTION ADJUSTABLE CLAMP TO MAIN UPPER ATTACHMENT PER SMACNA SUPPLY DUCT SIZE AS MAX. SAG Y2' PER FOOT SHOWN ON PLANS FLEXIBLE DUCT 8'-0" MAXIMUM LENGTH a BETWEEN SUPPORT POINTS MAXIMUM D/8 OFFSET ALLOWED IN LAST D INCHES TO DEVICE WHERE D IS THE INTERNAL FLEX DIAMETER SEE NOTE 3 VOLUME DAMPER WITH LOCKING ADJUSTABLE CLAMP STAINLESS STEEL QUADRANT AND 2" STANDOFF NECK SIZE TO MATCH DUCT SEALER FLEX DUCT SIZE INDICATE INSULATE TOP PANEL OF LAY -IN DIFFUSER 1 � CEILING (T -BAR SHOWN GYPSUM BOARD SIMILAR AIR DISTRIBUTION DEVICE, SEE PROVIDE CEILING ACCESS SCHEDULE. LAY -IN SHOWN- PANEL FOR DAMPER ACCESS SURFACE MOUNT SIMILAR IN NON -ACCESSIBLE CEILINGS NOTES: 1. FLEXIBLE DUCTS SHALL BE ONE-PIECE AND SHALL NOT BE SPLICED TOGETHER. 2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC. 3. MINIMUM 1-1/2" WIDE 22 GAUGE GALVANIZED STRAP HANGER WITH HEMMED EDGES PER SMACNA FIGURE 3-10. 4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW RADIUS NO LESS THAN R/D=1.0. 1 FLEXIBLE DUCT DETAIL NTS 00 a rney. 124 Fco C: 0 U U) U a� M m 0 U a� C a � .0 �0�00 C LLJ -�<�Pn G1 j - W C � a�o.� C Oor'.3< O ao o U =a 0 Nelson Blankenship, AIA X p.., v1Cn Fr{ W U N Y �k U H � �DQ U o QO � oa vi C) •� 0 �� 4-j N DRAWN CHECKED MJRXCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER M-40 I DATE 02-23-18 MECHANICAL SPECIFICATIONS GENERAL 2.1 CABINET PIPING ROUTED ALONG BUILDING EXTERIOR WALL SHALL BE PROTECTED BY SHEET METAL HOUSING THE GENERAL MECHANICAL SPECIFICATIONS APPLY TO THE WORK SPECIFIED IN THIS SECTION. A. CONSTRUCTION: SINGLE WALL SECURELY ATTACHED TO WALL AT 8'-0" INTERVALS AND PAINTED TO MATCH BUILDING EXTERIOR. B. EXTERIOR CASING: GALVANIZED STEEL WITH BAKED -ENAMEL PAINT FINISH WITH LIFTING LUGS AND SCOPE OF WORK KNOCKOUTS FOR ELECTRICAL AND PIPING CONNECTIONS. TRAP OIL IN SUCTION LINE AT EVAPORATOR COIL NO OTHER COIL TRAPS PERMITTED. PROVIDE FURNISH AND INSTALL COMPLETE AIR CONDITIONING SYSTEMS AS INDICATED ON THE DESIGN DRAWINGS 2.2 INTERIOR CASING - GALVANIZED STEEL SUCTION RISERS, CHECK VALVES, SOLENOID VALVES, OR OTHER DEVICES REQUIRED IN PIPING SYSTEM BY MANUFACTURER'S INSTALLATION INSTRUCTIONS. AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE A. BASE RAILS: GALVANIZED -STEEL RAILS FOR MOUNTING ON ROOF CURB. FABRICATION AND/OR INSTALLATION OF THE SCHEDULED AIR CONDITIONING UNITS, EXHAUST FANS, AIR B. SERVICE DOORS: HINGED ACCESS DOORS WITH NEOPRENE GASKETS. PIPE HANGERS AND SUPPORTS: DISTRIBUTION AND DUCTWORK. C. INTERNAL INSULATION: FIBROUS -GLASS DUCT LINING COMPLYING WITH ASTM C 1071, TYPE II. PIPE HANGERS, WHERE NEEDED, SHALL BE GRINNEL #260 CLEVIS TYPE, 5'-0" ON CENTER, SECURELY CLEANING, TESTING AND ADJUSTING: 1. THICKNESS: 1 INCH (25 MM). ATTACHED TO BUILDING CONSTRUCTION. SPACE AT MIN. 5'-0" INTERVALS. THE MECHANICAL CONTRACTOR, AT HIS EXPENSE, SHALL CLEAN, REPAIR, ADJUST, CHECK, BALANCE, AND 2. INSULATION ADHESIVE: COMPLY WITH ASTM C 916, TYPE I. PIPE SUPPORT: PLACE IN SERVICE THE VARIOUS SYSTEMS HEREIN SPECIFIED WITH THEIR RESPECTIVE EQUIPMENT, 3. MECHANICAL FASTENERS: GALVANIZED STEEL, SUITABLE FOR ADHESIVE ATTACHMENT, MECHANICAL ATTACH LINES SECURELY ALONG PAD/FLOOR/EQUIPMENT/STRUCTURE TO PREVENT MOVEMENT. SUPPORT ACCESSORIES AND PIPING. HE SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS ATTACHMENT, OR WELDING ATTACHMENT TO CASING WITHOUT DAMAGING LINER AND WITHOUT CAUSING AIR REQUIRED TO PERFORM TESTS REQUIRED BY THESE SPECIFICATIONS AND BY THE GOVERNING LEAKAGE WHEN APPLIED AS RECOMMENDED BY MANUFACTURER. IN A MANNER THAT LINES DO NOT HANG FROM EVAPORATOR CONNECTIONS OR BLOCK ACCESS TO AUTHORITIES. FILTERS, CONTROLS, ETC. D. CONDENSATE DRAIN PANS: FORMED SECTIONS OF STAINLESS-STEEL SHEET DESIGNED FOR SELF -DRAINAGE. NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY INSPECTED AND TESTED. FABRICATE PANS WITH SLOPES TO PRECLUDE BUILDUP OF MICROBIAL SLIME. PROVIDE FLOAT SWITCH. SUPPORT AT MIN. 8'-0" INTERVALS FOR VERTICAL PIPES, 5'-0" FOR SUSPENDED HORIZONTAL PIPING. E. ROOF CURB: FULL -PERIMETER CURB OF SHEET METAL, MINIMUM 14 INCHES HIGH, WITH WOOD NAILER, TESTING: NEOPRENE SEALING STRIP, AND WELDED Z -BAR FLASHING. EXHAUST FANS: ADJUST THE AIR CONDITIONING SYSTEMS, VENTILATING SYSTEMS, FANS, ETC., TO DELIVER NOT LESS 2.3 SUPPLY -AIR FAN THAN THE REQUIRED AIR QUANTITY WITH QUANTITIES IN EXCESS TO BE SUBJECT TO THE APPROVAL OF FURNISH EXHAUST FANS WITH PERFORMANCE AND CAPACITIES AS LISTED ON THE DESIGN DRAWINGS. THE ENGINEER IF FOUND TO NOT HAVE OBJECTIONABLE EFFECTS SUCH AS NOISE, DRAFTS, OR MOTOR OVERLOAD. A. FAN: FORWARD -CURVED CENTRIFUGAL; STATICALLY AND DYNAMICALLY BALANCED, GALVANIZED STEEL, SUSPENDED FANS SHALL BE SUPPORTED FROM A TRAPEZE TYPE HANGER WITH SPRING MOUNTED MOUNTED ON SOLID -STEEL SHAFT WITH SELF -ALIGNING, PERMANENTLY LUBRICATED BALL BEARINGS. VIBRATION ISOLATORS. B. MOTOR: TOTALLY ENCLOSED -SPEED MOTOR. THIS CONTRACTOR SHALL PROVIDE THREE (3) COPIES OF A TEST AND BALANCE REPORT TO THE OWNER C. DRIVE: V -BELT DRIVE WITH MATCHING FAN PULLEY AND ADJUSTABLE MOTOR SHEAVES AND BELT ASSEMBLY AT TIME OF SUBSTANTIAL COMPLETION INSPECTION. WITH MINIMUM 1.4 SERVICE FACTOR. ALL EXHAUST FANS SHALL COME WITH INTEGRAL BACKDRAFT DAMPER. D. MOUNTING: FAN WHEEL, MOTOR, AND DRIVES SHALL BE MOUNTED IN FAN CASING WITH SPRING ISOLATORS, THE TEST AND BALANCE REPORT SHALL BE TYPEWRITTEN AND CONTAIN THE FOLLOWING DATA: COORDINATE WITH ARCHITECT TO LOCATE EXHAUST FANS, EXHAUST GRILLES, WALL OR ROOF CAPS A 2.4 REFRIGERATION SYSTEM MINIMUM DISTANCE OF 10'-0" FROM ANY OPERABLE WINDOW, DOOR OR FRESH AIR INTAKE. 1. DATE, TIME, WEATHER, WHEN TEST TAKEN. 2. AIR CAPACITIES AT EACH UNIT INCLUDING OUTSIDE AIR. (ENTERING AND LEAVING DB/WB) A. FABRICATE AND LABEL REFRIGERATION SYSTEM TO COMPLY WITH ASHRAE 15, "SAFETY CODE FOR AIR DISTRIBUTION EQUIPMENT: 3. STATIC PRESSURE THROUGH UNITS AND UNIT COMPONENTS. MECHANICAL REFRIGERATION.' 4. MOTOR OPERATING VOLTAGE AND AMPERAGE. B. COMPRESSORS: RECIPROCATING OR SCROLL COMPRESSORS WITH INTEGRAL VIBRATION ISOLATORS, INTERNAL FURNISH SUPPLY AIR GRILLES AND RETURN AIR REGISTERS WITH OPPOSED BLADE BALANCING DAMPERS 5. DRIVE TYPES, SIZES AND SPEED RANGE. OVERCURRENT AND OVERTEMPERATURE PROTECTION, INTERNAL PRESSURE RELIEF. "ENERGY AS SCHEDULED ON THE DESIGN DRAWINGS. 6. IDENTIFICATION OF ALL AIR TERMINAL DEVICES WITH DESIGN CFM AND ACTUAL CFM. C. EER AND COP: 13 EER AND 11.8 COP VALUES AS DEFINED BY ASHRAE/IESNA 90.1, EFFICIENT DESIGN OF NEW BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS." GRILLES, REGISTERS, AND CEILING DIFFUSERS SHALL BE FURNISHED AS SCHEDULED ON THE DESIGN ADDITIONALLY, SYSTEMS DRAWING CLEARLY MARKED TO IDENTIFY LOCATION OF EQUIPMENT AND AIR D. REFRIGERANT: R -410A ON ALL NEW SYSTEMS. DRAWINGS AND SHALL BE ALL ALUMINUM CONSTRUCTION UNLESS NOTED OTHERWISE. AIR DISTRIBUTION DEVICES TESTED SHALL BE PROVIDED ALONG WITH THE WRITTEN TEST AND BALANCE REPORT. E. REFRIGERATION SYSTEM SPECIALTIES: EXPANSION VALVE WITH REPLACEABLE THERMOSTATIC ELEMENT SHALL NOT EXCEED NC -30 NOISE CRITERIA AS DEFINED IN THE LATEST ASHRAE GUIDE. MAINTENANCE MANUALS 1. REFRIGERANT DRYER. 2. HIGH-PRESSURE SWITCH. DUCTWORK: PROVIDE COMPLETE MAINTENANCE MANUALS (3 REQUIRED) ON ALL NEW EQUIPMENT. ORGANIZE 3. LOW-PRESSURE SWITCH. 4. THERMOSTAT FOR COIL FREEZE-UP PROTECTION DURING LOW AMBIENT TEMPERATURE OPERATION OR 1. ALL DUCTWORK DIMENSIONS ARE INSIDE NET FREE AREA. OPERATING AND MAINTENANCE DATA INTO SUITABLE SETS OF MANAGEABLE SIZE. BIND PROPERLY LOSS OF AIR. 2. SEAL ALL JOINTS WITH GLASS -FAB AND MASTIC. INDEXED DATA INTO INDIVIDUAL, HEAVY-DUTY, 2 -INCH, 3 -RING VINYL COVERED BINDERS WITH POCKET 5. BRASS SERVICE VALVES INSTALLED IN DISCHARGE AND LIQUID LINES. 3. ALL DUCTWORK SHOWN PER PLAN IS TO BE SHEET METAL FIBERGLASS DUCT BOARD IS NOT TO BE FOLDERS FOR FOLDED SHEET INFORMATION. MARK APPROPRIATE IDENTIFICATION ON FRONT AND SPINE 6. OPERATING CHARGE OF REFRIGERANT. INSTALLED UNLESS SPECIFICALLY AUTHORIZED BY THE BUILDING LANDLORD, PROJECT OWNER/AGENT OF EACH BINDER. INCLUDE THE FOLLOWING TYPES OF INFORMATION. THE INFORMATION WILL BE AND MECHANICAL ENGINEER OF RECORD. TURNED OVER TO THE OWNER AT TIME OF SUBSTANTIAL COMPLETION: 2.5 CAPACITY CONTROL 4. ALL EXHAUST AND OUTSIDE AIR DUCTWORK IS TO BE SHEET METAL - NO EXCEPTIONS. ADJUSTABLE SPUTTERS AND DAMPERS SHALL BE SUPPLIED AND INSTALLED IN EVERY SPLIT AND - OPERATING AND MAINTENANCE INSTRUCTIONS A. HOT -GAS BYPASS REFRIGERANT CONTROL FOR CAPACITY CONTROL WITH CONTINUOUS DEHUMIDIFICATION ON BRANCH DUCT AND SHALL BE PROVIDED WITH LOCKING QUADRANTS ON EXPOSED OR IN - SPARE PARTS LIST A SINGLE COMPRESSOR. ACCESSIBLE AREAS OF THE DUCT FOR EASE OF OPERATION. ACCESS PANELS OR YOUNG - COPIES OF WARRANTIES REGULATORS SHALL BE PROVIDED WHERE DAMPERS ARE INSTALLED ABOVE HARD CEILINGS OR IN - WIRING DIAGRAMS 2.6 REFRIGERANT COILS SOFFITS EVEN IF NOT STATED ON PLANS.ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN - INSPECTION REPORTS AND APPROVALS A. EVAPORATOR AND CONDENSER COILS SHALL BE DESIGNED, TESTED, FABRICATED, AND RATED ACCORDING TO 45 DEGREES SHALL BE FITTED WITH AIR TURNS CONSISTING OF CURVED AIRFOIL BLADES OR VANES - SHOP DRAWINGS AND PRODUCT DATA ARI 410 AND ASHRAE 33. COILS SHALL BE LEAK TESTED UNDER WATER WITH AIR AT 315 PSIG (2170 WHICH WILL PERMIT THE AIR TO MAKE ABRUPT TURNS WITHOUT APPRECIABLE TURBULENCE. KPA). 5. ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES SHALL BE FITTED WITH AIR TRAINING SERVICES TURNS CONSISTING OF CURVED AIRFOIL BLADES OR VANES WHICH WILL PERMIT THE AIR TO MAKE 1. CAPACITY REDUCTION: CIRCUIT COILS FOR FACE CONTROL ABRUPT TURNS WITHOUT APPRECIABLE TURBULENCE. LONG RADIUS TURNS ARE AN ACCEPTABLE THOROUGHLY INSTRUCT THE OWNER'S REPRESENTATIVE IN THE OPERATION OF ALL EQUIPMENT 2. TUBES: COPPER. SUBSTITUTE IF SPACE PERMITS. FURNISHED AND LOCATION OF ALL VALVES AND CONTROL DEVICES. 3. FINS: ALUMINUM 4. FIN AND TUBE JOINT: MECHANICAL BOND. - SHEET METAL DUCTWORK: SHALL BE CONSTRUCTED PER THE APPROPRIATE SMACNA DESIGN TRAIN BUILDING OWNER'S PERSONNEL DURING NORMAL WORKING HOURS ON STARTUP AND SHUTDOWN 5. SUCTION AND DISTRIBUTOR: SEAMLESS COPPER TUBE WITH BRAZED JOINTS. STANDARDS, MEETING THE MINIMUM GAUGE SHEET METAL THICKNESS SPECIFIED. INSULATE PROCEDURES, TROUBLESHOOTING PROCEDURES, SERVICING AND PREVENTATIVE MAINTENANCE SCHEDULE 6. COATING: PHENOLIC EPDXY CORROSION -PROTECTION COATING ON BOTH COILS. INTERNALLY OR EXTERNALLY WITH FIBERGLASS INSULATION TO ACHIEVE A MINIMUM R -VALUE OF AND PROCEDURES. REVIEW WITH THE OWNER'S PERSONNEL, THE DATA CONTAINED IN THE OPERATING 7. SOURCE QUALITY CONTROL- TEST T0.450 PSIG (3105 KPA), AND TO 300 PSIG (2070 KPA) 7.0 UNLESS INSTALLED IN A MECHANICALLY COOLED SPACE OR BETWEEN COOLED FLOORS IN A AND MAINTENANCE MANUALS. SCHEDULE TRAINING WITH OWNER, PROVIDE AT LEAST 7 -DAYS PRIOR UNDERWATER. CAVITY WHOSE EXTERIOR WALLS ARE INSULATED, IN WHICH CASE THE R -VALUE MAY BE 4.2. NOTICE TO ARCHITECT/ENGINEER. B. CONDENSER FAN: PROPELLER TYPE, DIRECTLY DRIVEN BY MOTOR. - FIBERGLASS DUCTWORK: SHALL BE CONSTRUCTEDOF OF FIBERGLASS FIBERBOARD DUCTWORK TO BE HANGERS AND SUPPORTS C. SAFETY CONTROLS: A MINIMUM OF 1" THICK. FIBERGLASS DUCTWORK SHALL BE LINED WITH ANTI MICROBIAL 1. COMPRESSOR MOTOR AND OUTSIDE -COIL FAN MOTOR LOW AMBIENT LOCKOUT. INSULATION EQUAL TO JOHNS -MANVILLE SUPERDUCT. INSULATE FIBERGLASS SUPPLY AND RETURN PROVIDE ALL NECESSARY HANGER RODS, CLAMPS AND ATTACHMENTS TO PROPERLY INSTALL AND 2. OVERCURRENT PROTECTION FOR COMPRESSOR MOTOR AND OUTSIDE -COIL FAN MOTORS. DUCTS CTS TO A MINIMUM R -VALUE OF 7.0 UNLESS INSTALLED IN A MECHANICALLY COOLED SPACE SUPPORT DUCTWORK, PIPING AND EQUIPMENT FROM THE BUILDING STRUCTURE. OR COOLED FLOORS INA CAVITY WHOSE EXTERIOR WALLS ARE INSULATED, IN WHICH 2.7 FILTERS CASE THE R -VALUE MAY BE 4.2. PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS REQUIRED TO INSTALL EQUIPMENT, PIPING AND DUCTWORK. A COMPLY WITH NEPA 90A. FLEXIBLE DUCTWORK SHALL BE SPIRAL FORMED OUT OF 3003 BRIGHT REFLECTIVE FINISHED B. DISPOSABLE PLEATED FILTERS: 2 -INCH- (50 -MM-) THICK, FACTORY -FABRICATED, FLAT -PANEL -TYPE, ALUMINUM ALLOY, MECHANICALLY LOCKED AND HAVE A MINIMUM R -VALUE OF 6.0. IT SHALL BE ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED, PRIMED AND PAINTED TO PREVENT DISPOSABLE AIR FILTERS WITH HOLDING FRAMES. UL LISTED UNDER CLASS 1 AIR DUCTS AND CLASS 1 CONNECTORS, MEET ALL REQUIREMENTS OF RUSTING. FINISH COLOR AS SELECTED BY OWNER. C. FILTER MEDIA TO BE INTERLACED GLASS FIBERS SPRAYED WITH NONFLAMMABLE ADHESIVE. UL 181 AND COMPLY WITH NFPA 90A AND NFPA 90B. D. FILTER FRAMES TO BE GALVANIZED STEEL THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS NOT ACCEPTABLE FOR SUPPORTS.- ROUND SPIRAL DUCTWORK: SHALL BE CONSTRUCTED PER THE APPROPRIATE SMACNA DESIGN 2.8 CONTROLS STANDARDS, MEETING THE MINIMUM GAUGE SHEET METAL THICKNESS SPECIFIED AND SHALL BE A WARRANTY/ GUARANTEE: MINIMUM 1" DOUBLE WALL INTERNALLY INSULATED. NON INSULATED SPIRAL DUCTWORK WILL NOT A. FACTORY -WIRE CONNECTION FOR CONTROLS' POWER SUPPLY. BE ACCEPTED AS A SUBSTITUTION. B. CONTROL DEVICES, INCLUDING SENSORS, TRANSMITTERS, RELAYS, SWITCHES, THERMOSTATS, HUMIDISTATS, THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS DETECTORS, OPERATORS, ACTUATORS, AND VALVES, SHALL BE MANUFACTURER'S STANDARD ITEMS TO VIBRATION ISOLATION: AND KEEP SAME IN PERFECT REPAIR AND CONDITION OF THE -PERIOD OF ONE (1) YEAR. ACCOMPLISH INDICATED CONTROL FUNCTIONS. C. UNIT CONTROLS: SOLID-STATE CONTROL BOARD AND COMPONENTS WITH FIELD -ADJUSTABLE CONTROL ALL BLOWER UNITS AND VIBRATING TYPE EQUIPMENT SHALL BE PROPERLY FITTED WITH MASON DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PARAMETERS. INDUSTRIES VIBRATION ISOLATION EQUIPMENT SIZED IN ACCORDANCE WITH EQUIPMENT WEIGHT AND DUTY. PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE D. SUPPLY -FAN CONTROL- UNITS SHALL BE ELECTRICALLY INTERLOCKED WITH CORRESPONDING EXHAUST SATISFACTION OF THE OWNER AND ARCHITECT AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH FANS, TO OPERATE CONTINUOUSLY WHEN EXHAUST FANS ARE RUNNING. TIME CLOCK SHALL SWITCH OPERATION FROM OCCUPIED TO UNOCCUPIED. NIGHT SETBACK THERMOSTAT SHALL CYCLE FAN DURING PROVIDE FLEXIBLE CONNECTORS AT ALL SUPPLY AND RETURN CONNECTIONS TO AIR HANDLING OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS THERETO. UNOCCUPIED PERIODS TO MAINTAIN SPACE TEMPERATURE. EQUIPMENT CONSISTING OF HEAVY CANVAS OR NEOPRENE FABRIC WITH AIRTIGHT SEAMS AND CONNECTIONS TO THE EQUIPMENT. EQUIPMENT: 1. TIMER: SEVEN-DAY ELECTRONIC CLOCK. AIR FILTERS: 1.1 QUALITY ASSURANCE E. ELECTRICALLY INTERLOCK KITCHEN HOOD FIRE -EXTINGUISHING SYSTEM TO DE -ENERGIZE REPLACEMENT -AIR UNIT WHEN FIRE -EXTINGUISHING SYSTEM DISCHARGES. FILTERS SHALL BE 1" FIBERGLASS MEDIA THROW AWAY TYPE IN A RIGID FRAME WITH A SUPPORTING A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, F. MINIMUM REFRIGERATION SYSTEM CONTROLS SHALL CONSIST OF A WALL -MOUNTING, RELATIVE -HUMIDITY AND TEMPERATURE SENSOR THAT ENERGIZES DEHUMIDIFIER OPERATION WHEN RELATIVE HUMIDITY IS MORE THAN MAZE ACROSS BOTH ENTERING AND LEAVING SURFACES. SUPPLY ONE COMPLETE SET OF FILTERS ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR 60 PERCENT. AFTER OWNERS FINAL ACCEPTANCE. FARR 30/30 OR EQUAL INTENDED USE. B. UNITS SHALL BE DESIGNED TO OPERATE WITH HCFC -FREE REFRIGERANTS. PIPING: HEAT PUMP UNIT INSTALLATION: 1.2 WARRANTY CONDENSATE DRAINS: PROVIDE CONCRETE PADS FOR GRADE MOUNTED CONDENSING UNITS. PADS SHALL BE A MINIMUM OF 4" THICK, 3,000 PSI CONCRETE, AND SHALL BE 4" LARGER ON EACH SIDE THAN THE FOOTPRINT OF A. SPECIAL WARRANTY. MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO REPLACE CONDENSATE PIPE TO BE TYPE L OR PVC. ROUTE TO DRYWELL OR AS INDICATED ON PLANS. THE CONDENSING UNIT. VERIFY UNIT DIMENSIONS WITH APPROVED SHOP DRAWINGS PRIOR TO LISTED BELOW THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED WARRANTY COMPOPERIOD. FABRICATION OF PADS. COORDINATE COORDINATE WITH PLUMBER TO PROVIDE HUB DRAIN(S) IN MECHANICAL ROOM AND DRYWELL(S). HVAC CONTRACTOR TO PROVIDE P -TRAP AT UNIT SIZED FOR 2" GREATER THAN UNIT STATIC PRESSURE. SUSPENDED UNITS SHALL BE SUPPORTED IN APPROVED MANNER AND IN ACCORDANCE WITH AIR 1. WARRANTY PERIOD FOR COMPRESSORS: MANUFACTURER'S STANDARD, BUT NOT LESS THAN FIVE (5) PROVIDE CLEANOUT AT UNIT FOR SUSPENDED HORIZONTAL AIR HANDLERS. INSULATE CONDENSATE PIPE HANDLING UNIT SUPPORT DETAIL PROVIDE AUXILIARY OVERFLOW DRAIN PAN WITH FLOAT SWITCH WHERE YEARS FROM DATE OF SUBSTANTIAL COMPLETION. WITH 1/2" ARMAFLEX (OR EQUAL) INSULATION RATED FOR PLENUM APPLICATION. CONDENSATE DRAIN REQUIRED. 2. WARRANTY PERIOD FOR HEAT EXCHANGERS: MANUFACTURER'S STANDARD, BUT NOT LESS THAN FIVE LINE SHALL BE NOT LESS THAN THE EQUIPMENT DRAIN LINE SIZE AND IN NO CASE LESS THAN 3/4- (5) YEARS FROM DATE OF SUBSTANTIAL COMPLETION. PIPE SIZE. ALL AIR HANDLING UNITS AND CONDENSING UNITS SHALL BE INSTALLED WITH MANUFACTURER REQUIRED 1.3 MANUFACTURERS MINIMUM MAINTENANCE CLEARANCES. PROVIDE MAN SIZED ACCESS PANEL WHERE REQUIRED. REFRIGERANT PIPING: A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: COVER ALL EXPOSED LIQUID LINES AND ALL SUCTION PIPING (INDOORS AND OUTDOORS), FITTINGS, FIRE DAMPERS: 1. MON VALVES, ETC., CONTINUOUS THROUGH SLEEVES, HANGERS, ETC., WITH 1/2" FR/ARMAFLEX. INSTALLATION FIRE DAMPERS SHALL BE TYPE "B" CURTAIN TYPE, SUITABLE FOR EITHER VERTICAL OR HORIZONTAL 2. TRANE SHALL BE CONDENSATION FREE AND INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. INSTALLATION WITH 20 GAUGE STEEL CHANNEL FRAMES, 24 GAUGE STEEL BLADES, AND 18 GAUGE 3. CARRIER STEEL ENCLOSURE WITH DUCT COLLARS. ALL PARTS GALVANIZED MILL FINISH. 4. YORK REFRIGERANT PIPING BELOW GRADE SHALL BE ROUTED THROUGH MINIMUM 4" DIAMETER PVC PIPE SLEEVES TO EACH CONDENSING UNIT. ALL UNDERGROUND REFRIGERANT PIPING SHALL BE CONTINUOUS FIRE DAMPERS SHALL BE EQUAL TO RUSKIN TYPE 1 BD2 FOR WALLS UP TO 2 HOUR. WITH NO UNDERGROUND JOINTS ALLOWED. REFRIGERANT PIPE SIZES SHALL BE SIZED PER A/C EQUIPMENT MANUFACTURER'S RECOMMENDATION BASED ON LENGTH OF RUN BETWEEN CONDENSING INSTALL IN ACCORDANCE WITH NFPA-90A, TESTED IN ACCORDANCE WITH UL SAFETY STANDARD 555, UNITS AND AHU UNITS. 1-1/2 HOUR AND 4 HOUR PROTECTION, AND 165'F FUSIBLE LINK. V lift 6 F .. NOTE: ALL OF THE SPECIFICATIONS LISTED ON THIS SHEET MAY NOT BE USED FOR THIS PROJECT.. sir A � P �o# ���4�ey m 0 U a� Q) czD 70 m Q= U v O N c ^o Lu c o�� a o C�) Nelson Blankenship, AIA uN 04 M ami W � o U ;� W 0 zx�w e�A UOQ a� Ct U Ct O .4cn ct (� •C) cn0 to `4n Q 1�0� A -a U N DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER M-501 DATE 02-23-18 LEGEND DIRECTION OF FLOW IN PIPE PITCH PIPE DOWN IN DIRECTION OF ARROW -0-0 PIPE UP - O PIPE DOWN EJ EXPANSION JOINT FLEXIBLE PIPE CONNECTOR -I®F-- BALL VALVE CHECK VALVE, HORIZONTAL SWING GATE VALVE wi BUTTERFLY VALVE GLOBE VALVE BALANCING VALVE -ICSI-B� BALANCING COCK STRAINER, Y -TYPE AND BLOWOFF VALVE RV PRESSURE RELIEF VALVE (WATER) PRESSURE REDUCING VALVE PRV MAV MANUAL AIR VENT SOLENOID VALVE VALVE OS & Y E CAPPED LINE - SAN SANITARY SEWER (ABOVE GRADE) - SAN - - SANITARY SEWER (BELOW GRADE) - DOMESTIC COLD WATER BP- BOOSTED PRESSURE DOMESTIC COLD WATER -- DOMESTIC HOT WATER - - - - DOMESTIC HOT WATER RETURN --CD-- CONDENSATE DRAIN (BELOW GRADE) CD CONDENSATE DRAIN (ABOVE GRADE) - - ST - - STORM SEWER (BELOW GRADE) ST STORM SEWER (ABOVE GRADE) EO STORM EMERGENCY OVERFLOW PIPING - - GR - GREASE SEWER (BELOW GRADE) GR GREASE SEWER (ABOVE GRADE) - -SCW - - SOFT COLD WATER VENT --G-- GAS LINE (BELOW GRADE) G GAS LINE (ABOVE GRADE) ® POINT OF CONNECTION NEW TO EXISTING POINT OF REMOVAL FOR DEMOLITION DT DELTA T (TEMPERATURE DIFFERENCE) A PHOTO DETAIL OR SECTION IDENTIFICATION TARGET B A = DETAIL NUMBER. B = SHEET NUMBER ON WHICH DETAIL IS LOCATED. HB HOSE BIBB FD ® FLOOR DRAIN HD O HUB DRAIN TD ® TRENCH DRAIN - - A- - COMPRESSED AIR (BELOW GRADE) A - COMPRESSED AIR (ABOVE GRADE) FLOOR CLEANOUT CLEANOUT EXTERIOR CLEANOUT HORIZONTAL CLEANOUT ITEMS TO BE REMOVED (DEMOLITION) CWN - COLD NANO WATER CWF COLD FILTERED WATER SHOCK ABSORBER NOTE: SYMBOLS SHOWN ON THIS PLUMBING LEGEND ARE FOR REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLS MAY NOT BE USED FOR THIS PROJECT. SPECIFICATIONS GENERAL NOTES PART 1 - GENERAL PART 2 - PRODUCTS 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY FITTINGS AS REQUIRED BY ALL APPLICABLE CODES AND GOVERNING AUTHORITIES. 1.1 SECTION INCLUDES 2.1 PIPE HANGERS AND SUPPORTS A. GENERAL PROVISIONS SPECIFICALLY APPLICABLE TO DIVISION 15 A. MANUFACTURERS: 2. CONTRACTOR SHALL VERIFY AND CORRECT AS REQUIRED TO MEET ALL CODES AND REGULATIONS ANY POSSIBLE SECTIONS, IN ADDITION TO DIVISION 1 - GENERAL A.1 B -LINE DISCREPANCIES BETWEEN TYPE AND SIZE OF CONNECTION SPECIFIED IN PLUMBING FIXTURE SCHEDULE AND FIXTURES REQUIREMENTS. A.2 OTHER- ACCEPTABLE MANUFACTURERS OFFERING ACTUALLY INSTALLED ON THE SITE. EQUIVALENT PRODUCTS. 1.2 SCOPE A.2.1 MICHIGAN HANGER 3. ALL DRAINAGE PIPING 21" AND LARGER SHALL HAVE A MINIMUM J" PER FOOT SLOPE. ALL DRAINAGE PIPING 2" AND A. THE WORK SHALL INCLUDE THE PROVISIONS OF SYSTEMS, A.2.2 PHD SMALLER SHALL HAVE A MINIMUM I" PER FOOT SLOPE, UNLESS OTHERWISE NOTED. EQUIPMENT AND MATERIALS SPECIFIED IN THIS DIVISION AND AS CALLED FOR ON THE DRAWINGS. WORK SHALL ALSO INCLUDE 2.2 PIPING INSULATION: 4. VENT PIPING SHOWN ON FLOOR PLANS IS ONLY INDICATIVE EXCEPT FOR VTR LOCATIONS. SUPERVISION, OPERATION, METHODS AND LABOR FOR THE A. MANUFACTURERS: FABRICATION, START-UP AND TESTS FOR A COMPLETE OPERATIONAL A.1 OWENS CORNING 5. VALVES AND FITTINGS SHALL BE OF SAME SIZE OF LINE ON WHICH THEY ARE LOCATED, UNLESS OTHERWISE INDICATED PLUMBING INSTALLATION. A.2 JOHNS MANVILLE A.3 KNAUF ON DRAWINGS. B. DRAWINGS FOR THE WORK ARE DIAGRAMMATIC IN NATURE AND ARE B. ASTM C547, RIGID MOLDED NON-COMBUSTIBLE FIBERGLASS 6. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES. INTENDED TO CONVEY THE SCOPE OF THE INSTALLATION AND TO INSULATION. 'K' VALUE .024 0 75 DEGREES F. INDICATE THE GENERAL ARRANGEMENT AND LOCATIONS OF THE C. VAPOR BARRIER JACKET, KRAFT PAPER WITH GLASS FIBER YARN AND 7. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS PRIOR TO LAYING AND CONNECTING ALL SANITARY AND WORK. BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC BONDED TO ALUMINUM FILM. CLOSURE SYSTEM SHALL BE UL 181. WASTE PIPING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. ITEMS SUCH AS PIPE FITTINGS, ACCESS PANELS, AND SLEEVES MAY D. INSULATION THICKNESS 1-1/0. ' NOT BE SHOWN. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR 8. AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER ARRESTORS AS SPECIFIED. SELECTING THE EQUIPMENT TO FIT THE SPACE PROVIDED. THE 2.3 PIPING: SANITARY SEWER PIPING LOCATION AND SIZES FOR PIPE FITTINGS, SLEEVES, INSERTS, FIRE A. PVC: ASTM D2665 SCHEDULE 40 PVC SOLID WALL PIPING. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING AND/OR SMOKE DAMPERS, AND OTHER BASIC ITEMS REQUIRED BY A.1 FITTINGS: ASTM D2665 SCHEDULE 40 PVC DWV FITTINGS. AND PENETRATIONS. CODE AND OTHER SECTIONS SHALL BE COORDINATED AND INCLUDED A.2 JOINTS: ASTM D2564 SOLVENT CEMENT. JOINTS SHALL FOR THE PROPER INSTALLATION OF THE WORK. BE INSTALLED IN ACCORDANCE WITH ASTM D2855. 10. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO PLANS AS POSSIBLE WITH NO CHANGES IN C. EQUIPMENT SPECIFICATIONS MAY NOT DEAL INDIVIDUALLY WITH 2.4 PIPING: WATER PIPING SIZING. MINUTE ITEMS REQUIRED SUCH AS COMPONENTS, PARTS, CONTROLS A. COPPER PIPING: ASTM B88 TYPE 'L' HARD DRAWN. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY SUPPORTING DEVICES FOR ALL FIXTURES AND DEVICES WHICH MAY BE REQUIRED TO PRODUCE THE A.1 FITTINGS: ASME 16.18 CAST BRONZE OR ASME B16.22 INCLUDED IN CONTRACT OR HEREIN SPECIFIED OR OTHERWISE. EQUIPMENT PERFORMANCE SPECIFIED OR AS REQUIRED TO MEET WROUGHT COPPER OR BRONZE. THE EQUIPMENT WARRANTIES. WHERE SUCH ITEMS ARE REQUIRED, A.2 JOINTS: ASTM B32 SOLDER, ASTM 95-5 TA MINIMUM, 12. CHANGES IN THE DIRECTION OF SANITARY PIPING SHALL NOT BE MADE WITH FITTINGS WHICH WILL CAUSE EXCESSIVE THEY SHALL BE INCLUDED BY THE INSTALLER OF THE EQUIPMENT, FLUX ASTM B813. JOINTS SHALL BE INSTALLED IN REDUCTION IN THE VELOCITY OF FLOW OR CREATE ANY OTHER ADVERSE EFFECT UNLESS PHYSICALLY IMPOSSIBLE (IE: WHETHER OR NOT SPECIFICALLY INDICATED IN THE CONTRACT ACCORDANCE WITH ASTM B828. USE OF SANITARY TEE IN A HORIZONTAL CON- NECTION, USE OF A DOUBLE SANITARY TEE IN A VERTICAL STACK, IN DOCUMENTS WITH NO ADDITIONAL COST INCURRED. A.3 SUBSTITUTIONS: CPVC IS AN ACCEPTABLE ALTERNATIVE GENERAL, USE OF SHORT -RADIUS FITTINGS FOR BRANCH TO HOUSE DRAIN OR STACK CONNECTION). D. WHERE NOTED ON THE DRAWINGS OR INDICATED IN OTHER SECTIONS TO COPPER ONLY IF APPROVED BY BUILDING OWNER. OF THE SPECIFICATION, THE CONTRACTOR FOR THIS DIVISION SHALL 2.5 PIPING: GAS PIPING 13. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL SANITATION FOUNDATION. INSTALL PLUMBING EQUIPMENT FURNISHED BY OTHERS, AND SHALL A. STEEL PIPE: ASTM A 53/A 53M; TYPE E OR S; GRADE B; BLACK. WALL 14. DO NOT PENETRATE FOUNDATIONS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR TO DROP FOUNDATIONS AS MAKE ALL FINAL CONNECTIONS. CONTRACTOR SHALL INSTALL THICKNESS OF WROUGHT -STEEL PIPE SHALL COMPLY WITH ASME B36.10M. REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING PENETRATING A BEARING WALL EQUIPMENT AND SYSTEMS IN STRICT ACCORDANCE WITH A.1 MALLEABLE -IRON THREADED FITTINGS: ASME B16.3, OR FOOTING MUST BE SLEEVED AND LOCATION APPROVED BY STRUCTURAL ENGINEER. MANUFACTURERS RECOMMENDATIONS. CLASS 150, STANDARD PATTERN, WITH THREADED ENDS ACCORDING TO ASME 81.20.1. 15. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES. PIPING EXPOSED SHALL BE SLOPED E. COORDINATE WITH ALL TRADES IN SUBMITTAL OF SHOP DRAWINGS. A.2 STEEL THREADED FITTINGS: ASME B16.11, FORGED STEEL AND PAINTED TO MATCH ARCHITECTURAL FINISHES. PIPING IN MECHANICAL ROOMS MAY BE EXPOSED. TIGHT SPACE CONDITIONS SHALL BE DETAILED TO THE SATISFACTION WITH THREADED ENDS ACCORDING TO ASME 81.20.1. OF ALL TRADES, SUBJECT TO THE REVIEW AND FINAL ACCEPTANCE A.3 STEEL WELDING FITTINGS: ASME 816.9, WROUGHT STEEL OR OF THE ARCHITECT/ENGINEER. IN THE EVENT THAT THE CONTRACTOR ASME 816.11, FORGED STEEL 16. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON- ACCESSIBLE CEILINGS. REFER TO INSTALLS HIS WORK BEFORE COORDINATING WITH OTHER TRADES OR A4 UNIONS: ASME B16.39, CLASS 150, . MALLEABLE IRON WITH ARCHITECTURAL DRAWINGS FOR CEILING TYPES. SO AS TO CAUSE ANY INTERFERENCE WITH THE WORK OF THE BRASS -TO -IRON SEAT, GROUND JOINT, AND THREADED ENDS OTHER TRADES THIS CONTRACTOR SHALL MAKE ALL REQUIRED ACCORDING TO ASME 81.20.1. 17. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF PLUMBING FIXTURE MOUNTING HEIGHTS, AND DIMENSIONS. CHANGES TO CORRECT THE CONDITION AT NO ADDITIONAL COST TO A.5 CAST-IRON FLANGES AND FLANGED FITTINGS: ASME 816.1, THE PROJECT. CLASS 125. 18. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH NEW SEWER LINES ARE TO BE CONNECTED A.6 JOINT COMPOUND AND TAPE- SUITABLE FOR NATURAL GAS. BEFORE INSTALLATION OF NEW SEWER LINE. A7 STEEL FLANGES AND FLANGED FITTINGS: ASME 816.5. F. CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTION SIZES A.8 GASKET MATERIAL- THICKNESS, MATERIAL, AND TYPE SUITABLE 19. ALL VENTS THROUGH ROOF SHALL BE MINIMUM OF 10'-0" FROM ANY AIR INTAKES. PRIOR TO INSTALLATION OF ANY SYSTEMS. THIS CONTRACTOR SHALL FOR NATURAL GAS. ADJUST PIPING SYSTEM SIZES AS REQUIRED TO MATCH EQUIPMENT 20. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS. CONNECTIONS. UTILIZE REDUCERS WHERE EQUIPMENT CONNECTIONS PART 3 - INSTALLATION ARE SMALLER THAN PIPE SIZES INDICATED ON PLANS, NO PIPING 21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS (INCLUDING PIPE ROUTING AND EQUIPMENT LOCATIONS) TO SHALL BE DECREASED IN SIZE (IN THE DIRECTION OF FLOW). 3.1 INSTALL .IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL PRIOR TO THE INSTALLATION OR PURCHASING OF ANY PIPING AND/OR 1.3 EXAMINATION OF BIDDING DOCUMENTS: 3.2 PROVIDE NON -CONDUCTING DIELECTRIC CONNECTIONS WHEREVER EQUIPMENT. A. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY JOINTING DISSIMILAR METALS. AND NOT LATER THAN TEN (10) DAYS PRIOR TO THE DATE FOR 22. PROVIDE 1/2" C.W. SUPPLY WITH ANGLE STOP AND FLEXIBLE SUPPLY TO RE- FRIGERATORS WITH ICE MAKERS AT RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO THE ENGINEER 3.3 ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRADIENT. HEIGHT REQUIRED BY MANUFACTURE OF EQUIPMENT INSTALLED. FOR INTERPRETATION OR CORRECTION OF ANY AMBIGUITY, 3.4 INSTALL PIPING TO CONSERVE BUILDING SPACE AND NOT INTERFERE WITH 23. PROVIDE 1 2" H.W. SUPPLY WITH ANGLE STOP AND FLEXIBLE SUPPLY TO DISH- WASHER MACHINE, AT HEIGHT INCONSISTENCY OR ERROR THEREIN. ANY INTERPRETATION OR / CORRECTION WILL BE ISSUED AS AN ADDENDUM BY THE ENGINEER.. - USE OF SPACE. REQUIRED BY MANUFACTURER OF EQUIPMENT INSTALLED. ONLY A WRITTEN INTERPRETATION OR CORRECTION TO BID DOCUMENTS BY ADDENDUM SHALL BE BINDING. NO BIDDER SHALL 3.5 GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS. 24. ALL WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE PLACED ON THE INTERIOR SIDE OF THE WALL, SO THAT RELY UPON ANY INTERPRETATION OR CORRECTION GIVEN BY ANY WALL INSULATION CAN BE PLACED ON THE EXTERIOR SIDE OF THE PIPING. OTHER METHOD. 3.6 INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, JOINTS, OR CONNECTED EQUIPMENT. 25. WHERE EXISTING PIPING IS DESIGNATED TO BE REMOVED AND CAPPED, ALL PIPING SERVING THE DESIGNATED FIXTURE 1.4 SUBSTITUTIONS: SHALL BE REMOVED FROM WITHIN WALLS TO THE POINT DESIGNATED ON THE DRAWINGS. PIPING SHALL BE CAPPED BY A. EXCEPT AS PROVIDED BELOW, EACH BIDDER REPRESENTS THAT HIS 3.7 PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND ACCESS TO APPROVED CAPPING METHODS UTILIZING PIPE CAPS INTENDED FOR SUCH USE. CAPS SHALL BE AIRTIGHT AND BID IS BASED UPON THE MATERIALS AND EQUIPMENT DESCRIBED IN VALVES AND FITTINGS. WATERTIGHT. THE BIDDING DOCUMENTS. 3.8 PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT EXPOSED. 26. WHERE EXISTING SURFACES ARE DISRUPTED DUE TO THE REMOVAL OF EXISTING EQUIPMENT OR PIPING, THIS B. NO SUBSTITUTIONS FOR OTHER MATERIALS AND EQUIPMENT WILL BE COORDINATE SIZE AND LOCATION OF ACCESS DOORS WITH APPROPRIATE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF DISRUPTED SURFACES TO MATCH EXISTING ADJACENT CONSIDERED UNLESS WRITTEN REQUEST HAS BEEN SUBMITTED TO ARCHITECTURAL SECTION. SURFACES. THE ENGINEER FOR APPROVAL AT LEAST TEN (10) DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS. EACH SUCH REQUEST SHALL 3.9 ESTABLISH ELEVATIONS OF BURIED PIPING OUTSIDE THE BUILDING TO 27. EXISTING CONDITIONS AS SHOWN ON THE DRAWINGS ARE TAKEN FROM ORIGINAL AND AS -BUILT DRAWINGS OF THE INCLUDE A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE, ENSURE PROPER SLOPE AND COVER. BUILDING AND IN PART -ARE UNVERIFIED. FIELD CONDITIONS SHALL GOVERN. ALL EXISTING CONDITIONS MUST BE THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT IS TO VERIFIED PRIOR TO INITIATION OF WORK. BE SUBSTITUTED, DRAWINGS, CUTS, PERFORMANCE AND TEST DATA 3.10 ESTABLISH ELEVATIONS OF EXISTING BURIED PIPING FOR CONNECTION TO OR INFORMATION NECESSARY FOR A COMPLETE EVALUATION. NEW WORK TO ENSURE PROPER SLOPE AND COVER. 28. ALL EXISTING PIPING, NOT REMAINING IN SERVICE AFTER NEW CONSTRUCTION, SHALL BE REMOVED. C. IF THE ENGINEER APPROVES ANY PROPOSED SUBSTITUTION, SUCH 3.11 WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL BUILDING 29. PIPING WHICH IS TO REMAIN IN SERVICE SHALL NOT BE DISTURBED. EXISTING PIPING DAMAGED DURING CONSTRUCTION APPROVAL WILL BE ISSUED AS AN ADDENDUM FORWARDED TO ALL FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT OF ZINC RICH SHALL BE REPLACED WITH NEW PIPING OF THE SAME SIZE AND MATERIAL PARTICIPATING BIDDERS. PRIMER TO WELDING. 30. EXISTING BUILDING SEWERS THAT ARE USED WITH NEW BUILDING SANITARY SEWERS SHALL BE EXAMINED AND TESTED D. IF ANY BIDDER IS UNABLE TO PROCURE WRITTEN APPROVAL OF ANY 3.12 EXTEND CLEANOUTS TO FINISHED FLOOR OR WALL SURFACE. LUBRICATE TO CONFORM IN ALL RESPECTS TO ALL THE REQUIREMENTS OF PLUMBING AUTHORITY HAVING JURISDICTION AND SUBSTITUTION FROM THE ENGINEER PRIOR TO THE OPENING OF THREADED CLEANOUT PLUGS WITH MIXTURE OF GRAPHITE AND LINSEED APPLICABLE PLUMBING CODES. BIDS, THEN HE SHALL BASE HIS BID ON ITEMS AND SYSTEMS AS OIL ENSURE CLEARANCE AT CLEANOUT FOR RODDING OF DRAINAGE SPECIFIED IN BID DOCUMENTS. SYSTEM. 31. ALL EXISTING SANITARY, DOMESTIC WATER, AND RAIN WATER PIPING THAT ARE LOCATED IN EXISTING WALLS TO BE E. SUBSTITUTIONS REQUESTED ON THE BID PROPOSAL FORM WHICH 3.13 RESET SPRINKLER HEADS FROM UPRIGHT POSITION TO DOWN POSITION DEMOLISHED AND REMAINING IN SERVICE AFTER CONSTRUCTION SHALL BE RELOCATED TO NEW WALLS, CHASES, ETC. ARE PRIOR APPROVED BY THE ENGINEER WILL BE INCORPORATED TO CENTER OF NEW CEILING TILE. 32. COORDINATE WITH GENERAL CONTRACTOR TO PATCH ALL EXISTING WALLS, FLOORS, CEILINGS, ETC., AS REQUIRED BY INTO THE CONTRACT WITH THE SUCCESSFUL BIDDER. NEW WORK. SEE SPECIFICATIONS. 3.14 TORQUE ALL HUBLESS CAST IRON COUPLING IN STRICT ACCORDANCE F. REQUESTS FOR ANY SUBSTITUTIONS NOT SUBMITTED AND APPROVED WITH THE MANUFACTURERS RECOMMENDATIONS. UTILIZE COUPLING 33. IT IS THE PLUMBING CONTRACTORS RESPONSIBILITY TO PROVIDE A DOUBLE CHECK VALVE BACKFLOW PREVENTION IN ACCORDANCE WITH THE ABOVE INSTRUCTIONS WILL BE DENIED BY MANUFACTURERS PRE-SET TORQUE WRENCH. DEVICE ON THE MAIN DOMESTIC WATER SERVICE PROVIDED TO THE BUILDING/SPACE UNDER CONSTRUCTION AS PER THE THE ENGINEER. LATEST ADOPTED VERSION OF THE PLUMBING CODE EVEN IF THE BACKFLOW PREVENTION DEVICE IS NOT CALLED OUT 3.15 INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH FIXTURE OR SPECIFICALLY ON THE PLANS. 1.5 REGULATORY REQUIREMENTS: BATTERY OF FIXTURES. ARRESTORS SHALL BE FACTORY FABRICATED. A. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN STRICT INSTALL ARRESTORS AND SIZE PER PLUMBING AND DRAINAGE INSTITUTE 34. FIELD VERIFICATION OF EXISTING PIPING: ALL EXISTING PIPING SHOWN ON THE CONSTRUCTION DOCUMENTS IS BASED ACCORDANCE WITH ALL APPLICABLE STATUTES, CODES AND STANDARD P.D.I. WH -201. ACCEPTABLE MANUFACTURERS ZURN, JOSAM, OFF OF VISUAL SITE INVESTIGATION AND AS BUILTS DRAWINGS OF THE EXISTING SITE AND BUILDING CONSTRUCTION. REGULATIONS OF THE GOVERNMENTAL BODIES HAVING JURISDICTION. SIOUX CHIEF. PPP INC. FOR 1-11 FU'S PROVIDE PDI -A, FOR 12-32 THE ENGINEER DOES NOT HAVE XRAY VISION. IT IS THE RESPONSIBILITY OF THE LICENSED PLUMBING 'CONTRACTOR TO B. CONFORM TO 2014 FLORIDA PLUMBING CODE. FU'S PDI -B, 33-60 FU'S PDI -C, 61-113 FU'S PDI -D. FIELD VERIFY ALL EXISTING PIPING LOCATIONS, TYPES, SIZES, ELEVATIONS AND INVERTS. NOTIFY ENGINEER IF THE C. CONFORM TO 2014 FLORIDA FIRE PREVENTION CODE. CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATE IN THE SPECIFICATIONS PRIOR TO THE INITIATION OF D. CONFORM TO 2014 FLORIDA BUILDING CODE. ANY WORK. IDENTIFICATION AND VERIFICATION OF EXISTING PIPING TO BE ACCOMPLISHED BY THE FOLLOWING MEANS: • MANDATORY DYE TESTING OF ALL EXISTING SANITARY, STORM AND GREASE WASTE PIPING FOR SYSTEM 1.6 CUTTING AND PATCHING: IDENTIFICATION. A. SUBMIT WRITTEN REQUEST IN ADVANCE OF CUTTING OR ALTERING • SNAKE ALL SANITARY, STORM AND GREASE WASTE PIPING FOR A DISTANCE OF 100 FEET AND REPORT ANY ELEMENTS. BLOCKAGES. • TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDING EQUIPMENT SUPPLIED OR TO BE B. EMPLOY SKILLED AND EXPERIENCED INSTALLER TO PERFORM INSTALLED. CUTTING AND PATCHING WHICH EFFECT. • ALL IDENTIFICATION AND VERIFICATION RESULTS SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW B.1 STRUCTURAL INTEGRITY OF ELEMENT. PRIOR TO THE INITIATION OF ANY WORK. B.2 INTEGRITY OF WEATHER. B.3 EFFICIENCY, MAINTENANCE, OR _SAFETY OF ELEMENT. B.4 VISUAL QUALITIES OF SIGHT. B.5 WORK OF OWNER OR SEPARATE CONTRACTOR. ! Nvt%ep1H IMIY3190 r f i r �, Jas 24 hey Fm 70 Q U m D - ro m LL ° Uy mo C •C �,O�^ nEW 3 Q, <7 a J � 72N Z c 00 - _ Z mm ° Nelson Blankenship, AIA r 1, o UN U F -i � N Q�'D �UO� W Uo~^r. 5 o o� 01 H cn o 1�O Z O �_4 �^ ct OblJ � � 4J a N DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER P-00 I DATE 02-23-18 f Floor Plan - Plumbing SCALE: 1/8"=1'-0" Mezzanine Floor Plan - Plumbing SCALE: 1/8"=1'-0" REFERENCE NOTES: o (D CONNECT NEW Xi" COLD WATER LINE TO EXISTING COLD WATER LINE AT POINT OF CONNECTION SHOWN. FIELD VERIFY EXACT LOCATION OF EXISTING COLD WATER LINE PRIOR TO START OF CONSTRUCTION. O2 CONNECT NEW 3" SANITARY LINE TO EXISTING SANITARY LINE AT POINT OF CONNECTION SHOWN. FIELD VERIFY EXACT LOCATION OF EXISTING SANITARY LINE PRIOR TO START OF CONSTRUCTION. � :, � S • r w � �Q OF i�iAr� FFSo 10 ane I P. ra a 12 OD 0 U t!1 a� a� 0 a� 0 U � Q G> O N M D C V N a0C = a 0 mF o- Nelson Blankenship, AIA a�QA W� o xj u �UQ� a� U o a 40. H M N ct Ha O � Q � ~ 0 DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER P-201 DATE 02-23-18 i > > FCO i i \ \ \ \ \ a i r AAV -1 WC -1 4 SANITARY RISER DIAGRAM NTS TEST TEE THREADED CLEANOUT FINISHED WALL SURFACE ACCESS COVER AND FRAME 2 � WALL CLEAN OUT DETAIL NTS J it I \ j � SII SINK � I I I � I � I i.�.e...., ....'4 ....-._..tea........ .�.... a. __,.., ._, .._.�_3 .... _.. ,._. .e e...e. .............e. �t... .�.._._.3 - S r TEMPERED HOT WATER TO SINK. COLD WATER DOWN IN PROVIDE FLOW 1 �_ �'� WALL CONTROL FITTING AND I � --~t�� 1�Wll COLD WATER SUPPLY TO SINK INSULATE ALL PIPING. INSTANTANEOUS POINT TWO-WAY VALVE OF USE WATER HEATER. INSTANTANEOUS WATER HEATER NTs PIPING DETAIL SOIL PIPE - SEE PLAN PLANS FOR SIZE THREAD BRASS CLEANOUT COVER W/RECESSED SLOT FINISHED FLOOR—\ . COMBINATION WYE & 1/8 BEND NTS EXTENSION PIECE (SIZE AS NEEDED) ELEVATION FLOOR CLEAN OUT DETAIL PLUMBING FIXTURE SCHEDULE MARK FIXTURE WASTE TRAP VENT COLD WATER HOT WATER MANUFACTURER /MODEL # DESCRIPTION CL U WC -1 WATER CLOSET -ADA 3" INTEG 2" 1/2" - AMERICAN STANDARD RIM 17" AFF. FLOOR MOUNTED TANK TYPE, VITREOUS CHINA, 1.6 GPF, ELONGATED BOWL, N 2586.000 BOLT CAPS. COORDINATE FINISH WITH ARCHITECT. SOLID PLASTIC ELONGATED SEAT (WHITE) • W/S,S, CHECK HINGES, WATERSENSE CERTIFIED L-1 LAVATORY -ADA 1-1/2" 1-1/4" 1-1/2" 1/2" 1/2" AMERICAN STANDARD VITREOUS CHINA, WHITE, WALL HUNG, FRONT OVERFLOW. COMPLETE WITH STOPS AND 0 o� u It O N �o � -0�0' N = N O � p.'n Jia 0321.026 TRAP. PROVIDE WITH AMERICAN STANDARD 4" CENTERSET ANTI -SCALD FAUCET, .5 GPM. Nelson Blankenship, AIA r) a� m 04 aY�i xi cC WATERSENSE CERTIFIED. - AAV -1 AIR ADMITTANCE VALVE - - 1-1/2" - - STUDOR AUTOMATIC AIR ADMITTANCE VALVE WITH VENTED ACCESS PANEL. LOCATE FULLY TEC -VENT ACCESSIBLE. FCO -1 FLOOR CLEANOUT SEE PLAN - - - - ZURN "LEVEL-TROL" ADJUSTABLE FINISHED FLOOR CLEANOUT, DURA -COATED CAST IRON Z1400 BODY WITH GAS AND WATERTIGHT ABS TAPERED THREADED PLUG, AND ROUND c� I �c ct H SCORIATED SECURED TOP. ADJUST TO FINISHED FLOOR (COORDINATE TOP FINISH WITH a ARCHITECT). WCO-1 WALL CLEANOUT SEE PLAN - - - - ZURN CAST IRON CLEAN-OUT TEE, DURA COATED BODY, GAS AND WATERTIGHT ABS TAPERED U DRAWN CHECKED MJR/KCM Z1446 THREAD PLUG AND ROUND, SMOOTH STAINLESS STEEL WALL ACCESS COVER WITH 1716 DRAWING NUMBER P - 3 0 1 DATE 02-23-18 SECURING SCREW. NOTES: 1. ALL PLUMBING FIXTURES SHALL BE SUPPLED WITH WATTS "FLOODSAFE" AUTO -SHUT OFF CONNECTOR TYPE SUPPLY RISERS WITH BRAIDED STAINLESS STEEL CONNECTORS. THIS SHALL INCLUDE ALL FAUCETS, TOILETS AND WATER FOUNTAINS. 2. PROVIDE FULLY ACCESSIBLE WATER HAMMER ARRESTORS ON ALL MAIN VERTICAL DROPS TO PLUMBING FIXTURE GROUPS. ELECTRIC INSTANTANEOUS WATER HEATER SCHEDULE FIXTURE LOCATION STORAGE VOLTAGE/KW I AMPERAGE NO. OF TEMP RISE SIZE (IN.). OPERATIONAL MANUFACTURER MODEL NUMBER ACCESSORIES N0. CAPACITY PHASE ELEMENTS ® 0.5 GPM WEIGHT (LBS). IWH-1 UNISEX NONE 120V 10 3.0 25 1 41 DEG. ® 0.5 GPM 5 1/2" x 11" 4 EEMAX EX3012 PROVIDE WITH RESTROOM / / MOUNTING BRACKETS 00 ney ��►.5a#tI��124 00 7 Ic 0 CL U U N N 0 o� u It O N �o � -0�0' N = N O � p.'n Jia s =$ Nelson Blankenship, AIA r) a� m 04 aY�i xi cC �0 ww qQ U 0 Qa�� Uo r—+ U � � M 00 c� I �c ct H a � U DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER P - 3 0 1 DATE 02-23-18 ELECTRICAL LEGEND ABBREVIATIONS WIRING AND POWER PANELS 51 FT TO 75 FT 76 FT TO 100 FT 101 FT TO 125 FT AMPERES 151 FT TO 200 FT 120V 20A #12 #10 A - #8 S* SWITCH 30A #10 #8 1 #6 #6 1 #6 NEW ELECTRICAL PANEL 40A #8 #6 #6 #4 #4 A/C — AIR CONDITIONING . #2 208V 1 XXX #12 #12 AC — ALTERNATING CURRENT #10 (NONE) SINGLE POLE TOGGLE SWITCH 30A #10 #10 #10 #8 #8 MDP MAIN DISTRIBUTION PANEL (SEE PANEL SCHEDULE) 40A #8 #8 #8 #8 #6 AFF — ABOVE FINISHED FLOOR #4 2 TWO POLE TOGGLE SWITCH #4 TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION #3 BOA #4 #4 #4 #4 4 #3 90A #3 #3 #3 #3 #3 3 THREE WAY TOGGLE SWITCH 100A #3 #3 #3 #3 #3 #2 AFG — ABOVE FINISHED GRADE #12 WP SINGLE POLE WEATHERPROOF SWITCH ATs AUTOMATIC TRANSFER SWITCH #8 AHU — AIR HANDLING UNIT #10 K SINGLE POLE KEYED SWITCH #10 #8 #8 #6 40A #8 #8 #8 #8 #6 #6 OS - OCCUPANCY SENSOR SWITCH ® ELECTRICAL SYSTEMS PANEL #4 AWG — AMERICAN WIRE GAUGE BOA #4 #4 #4 #4 #4 M MANUAL MOTOR CONTROLLER W/O OVERLOADS XXX #3 100A 3 3 #3 #3 #3 C — CONDUIT ZUc N SACP SECURITY ALARM CONTROL PANEL F+i 4 Cl C. a FACP FIRE ALARM CONTROL PANEL CFL- — COMPACT FLUORESCENT LAMP S abc LOWER CASE LETTERS INDICATES SWITCHING DESIGNATIONS, MC MASTER CLOCK CONTROL PANEL CH — COUNTER HEIGHT QUANTITY OF LETTERS EQUAL QUANTITY OF GANGED SWITCHES PA PUBLIC ADDRESS CONTROL PANEL U W IMP FIRE ALARM ANNUNCIATOR PANEL CONC — CONCRETE COND — CONDUIT (P* SINGLE RECEPTACLE CU — COPPER GFI GROUND FAULT CIRCUIT INTERRUPTER LIGHTING O DISC — DISCONNECT WP WEATHERPROOF IG ISOLATED GROUND ECB — ENCLOSED CIRCUIT BREAKER C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) F=_1 XX LIGHTING FIXTURE ELEC — ELECTRICAL DRAWN CHECKED MJP/KCM Q (SEE LIGHTING FIXTURE SCHEDULE FOR LETTER PROJECT NUMBER EM — EMERGENCY DRAWING NUMBER E-001 DESIGNATION AND DESCRIPTION OF FIXTURES) DATE 02-23-18 71' DUPLEX RECEPTACLE I r EMS — ENERGY MANAGEMENT SYSTEM * EF — EXHAUST FAN GFI GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF EMERGENCY/NIGHT LIGHT LIGHTING FIXTURE EMT — ELECTRICAL METALLIC TUBING IG ISOLATED GROUND EWC - ELECTRIC WATER COOLER C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) ® ® EXIT LIGHTING FIXTURE UNIVERSAL MOUNT, SINGLE/DOUBLE FACE ETR — EXISTING TO REMAIN EWC ELECTRIC WATER COOLER, COORDINATE LOCATION . (WHERE USED, ARROW INDICATES CHEVRON DIRECTION) WITH PLUMBING CONTRACTOR _ EX — EXISTING BATTERY POWERED EMERGENCY LIGHT FA — FIRE ALARM zm IS QUADRAPLEX RECEPTACLE —C EMERGENCY LIGHT REMOTE HEAD IMP — FIRE ALARM ANNUNCIATOR PANEL GFI GROUND FAULT CIRCUIT INTERRUPTER I—T� TRACK LIGHTING FACP — FIRE ALARM CONTROL PANEL WP WEATHERPROOF G — GROUND IG ISOLATED GROUND D TRACK LIGHTING HEAD GFI — GROUND FAULT INTERRUPTER C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) WG WIRE CAGE LIGHT GUARD GND — GROUND Q* SPECIAL RECEPTACLE OS OCCUPANCY SENSOR —CEILING MOUNTED GRC — GALVANIZED RIGID CONDUITH.LD. — HIGH INTENSITY DISCHARGE X TYPE X (SEE RECEPTACLE SCHEDULE) CSC OCCUPANCY SENSOR — CEILING MOUNTED — CORRIDOR HVAC — HEATING, VENTILATING, AND AIR CONDITIONING C COUNTER HEIGHT CSW OCCUPANCY SENSOR — WALL MOUNTED I,G. — ISOLATED GROUND PP ❑ POWER POLE J — JUNCTION ® RECESSED FLOOR MOUNTED DUPLEX RECEPTACLE LC LIGHTING CONTACTOR KAIC — (THOUSAND) AMPERE INTERRUPTING CAPACITY O SURFACE—MOUNTED FLOOR DUPLEX RECEPTACLE PC PHOTOCELL KVA — KILOVOLT—AMPERES O CEILING—MOUNTED DUPLEX RECEPTACLES * SWITCH KW — KILOWATT LTG — LIGHTING PLUG MOLD OS OCCUPANCY SENSOR SWITCH MCM — THOUSANDS OF CIRCULAR MILS D DIMMER D3 THREE WAY DIMMER (INCANDESCENT) MCU — MASTER CONTROL UNIT C COUNTER HEIGHT MCP — MOTOR CIRCUIT PROTECTION ❑-J JUNCTION BOX MH - METAL HALIDE . DISCONNECT SWITCH FIRE ALARM S I STEMS N — NEUTRAL NA — NOT APPLICABLE OWP DISCONNECT SWITCH — WEATHERPROOF (NEMA 3R) NF — NON—FUSED FUSED. DISCONNECT SWITCH DD DUCT DETECTOR NL — NIGHT LIGHT FSR FIRE ALARM SHUT DOWN RELAY NEC — NATIONAL ELECTRICAL CODE 8 MAGNETIC MOTOR STARTER NEMA — NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION COMBINATION DISCONNECT/ T E L E C OM A 1 /�M I ' V N I CAT I O N S NFPA — NATIONAL FIRE PROTECTION ASSOCIATION MAGNETICSTARTER SWITCH NIC — NOT IN CONTRACT HOA HAND/OFF/AUTO v DATA/COMM OUTLET O.C. — ON CENTER SS START/STOP O.F.C.I. — OWNER FURNISHED CONTRACTOR INSTALLED ®M MANUAL STARTER ® TELEVISION OUTLET P — POLE SP SPEAKER PNL — PANELBOARD vsD COMBINATION VARIABLE SPEED DRIVE AND DISCONNECT PVC — POLYVINYL CHLORIDE RGS — RIGID GALVANIZED STEEL VSD VARIABLE SPEED DRIVE RM — ROOM / - `�-� EF -1 MOTOR WITH DESIGNATOR SPEC — SPECIFICATION TC TIME CLOCK SS — STAINLESS STEEL TVSS — TRANSIENT VOLTAGE SURGE SUPPRESSION WH WATER HEATER TYP — TYPICAL HVP1-6 BRANCH CIRCUIT HOME RUN WITH PANEL NAME AND CIRCUIT NUMBER, UON - UNLESS OTHERWISE NOTED �a QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS V — VOLTS W — WIRE BRANCH CIRCUIT WIRING, PROVIDE QUANTITIES OF CONDUCTORS REQUIRED FOR CIRCUITING AND SWITCHING INDICATED WP — WEATHERPROOF POWER LEG ONLY (NO SWITCH LEG BETWEEN ROOMS) ❑� MUSHROOM HEAD PUSH BUTTON (EMERGENCY STOP) ❑R RELAY GROUND ROD FTI TRANSFORMER T❑ TYPE "K" TRANSFORMER K UH ELECTRIC UNIT HEATER (FURNISHED UNDER DIV 15 UNLESS NOTED OTHERWISE) NOTE: SYMBOLS SHOWN ON THIS ELECTRICAL LEGEND ARE FOR REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLS MAY NOT BE USED FOR THIS PROJECT. GENERAL NOTES 1) ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE= LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE (NFPA 70), AND THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING CODE. 2) CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND COORDINATE WITH EXISTING EQUIPMENT PRIOR TO BIDDING. 3) ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABEL LISTED BY AN APPROVED THIRD—PARTY TESTING AGENCY. BUILDING: 4) INSTALLATION HEIGHT OF EQUIPMENT (TO CENTERLINE) ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE SHALL BE: RECEPTACLE = 18" CLOCK = 7-6" SWITCH = 44" MODULAR JACK FOR WALL MOUNTED TELEPHONE = 52" MODULAR TELEPHONE JACK = 18" TELEVISION OUTLET = 84" COMPUTER OUTLET = 18" CALL SWITCH = 44" REMOTE TEST STATION FOR DUCT DETECTOR = 52" C = ABOVE COUNTER BACKSPLASH, COORDINATE WITH ARCHITECTURAL ELEVATIONS AND MILLWORK. 5) ALL CONDUIT AND WIRING SHALL BE CONCEALED IN WALLS OR ABOVE CEILINGS UNLESS NOTED OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. ALL DEVICE OUTLET BOXES SHALL BE RECESSED UNLESS NOTED OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. WHERE APPROVED OR NOTED SURFACE METAL RACEWAY AND DEVICE BOXES SHALL BE USED IN LIEU OF CONDUIT AND CONCEALED BOXES AT NO EXTRA COST TO THE OWNER. 6) ALL CONDUIT ROUTES SHOWN ARE APPROXIMATE ONLY. CONTRACTOR SHALL FIELD VERIFY FINAL ROUTE. 7) CONDUIT RUNS SHOWN ARE SCHEMATIC AND DO NOT INDICATE THE NECESSARY FITTINGS AND JUNCTION BOXES THAT ARE INCLUDED IN THE SCOPE OF THE WORK. 8) CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL WIRING WITH THE SOURCE AND CIRCUIT AT ALL ELECTRICAL EQUIPMENT, PULL AND JUNCTION BOXES AND ELECTRICAL TERMINATIONS PROVIDED OR ASSOCIATED WITH THIS CONSTRUCTION. 9) CONTRACTOR SHALL PATCH AND REPAIR ALL DAMAGED SURFACES AND AREAS WHERE EQUIPMENT WAS REMOVED OR MODIFIED, TO MATCH EXISTING CONDITIONS. 10) ALL ABANDONED AUDIO OR CONTROL CABLES SHALL BE REMOVED. ALL BOX OR EQUIPMENT OPENINGS SHALL BE CLOSED WITH LISTED CLOSURE DEVICE AS APPROVED BY THE EQUIPMENT MANUFACTURER. 11) WHERE EXISTING EQUIPMENT OR MATERIALS ARE REMOVED OR CHANGED, ALL BRANCH CONDUITS WHICH NO LONGER ARE IN SERVICE, SHALL BE REMOVED AS DIRECTED BY THE ENGINEER. IF, IN THE COURSE OF THIS WORK, OUTLETS ARE COVERED UP OR OTHERWISE RENDERED INACCESSIBLE, ALL WIRING TO SAME SHALL BE REMOVED TO THE SOURCE. IF A CIRCUIT THAT MUST REMAIN IN SERVICE IS INTERRUPTED THEREBY, IT SHALL BE RECONNECTED BY THE MOST INCONSPICUOUS MEANS SO AS TO REMAIN OPERATIONAL, WITH THE SAME CAPACITY AS BEFORE. ALL BUILDING SURFACES DAMAGED, AND OPENINGS LEFT BY REMOVAL OF BOXES, PIPING OR OTHER EQUIPMENT SHALL BE REPAIRED BY THE CONTRACTOR. ALL HOLES LEFT IN JUNCTION BOXES, SWITCHES, PANELS, ETC. SHALL BE CLOSED. 12) ALL REUSABLE DEVICES, FIXTURES AND EQUIPMENT SHALL BECOME THE PROPERTY OF THE OWNER. ALL OTHER SALVAGE AND DEBRIS SHALL BE REMOVED FROM THE PREMISES DAILY. 13) THIS CONTRACTOR SHALL FURNISH AND PROVIDE ALL DEMOLITION REQUIRED TO ACCOMMODATE THIS PROJECT WHETHER INDICATED ON DRAWINGS, OR DIRECTED IN THE FIELD. GROUNDING: 14) ALL METAL RACEWAYS, INCLUDING CONDUIT, WIRE TROUGHS, WIREMOLD, ETC., SHALL BE GROUNDED. ALL CONNECTIONS IN METAL RACEWAYS SHALL BE COMPLETED IN SUCH A MANNER AS TO MAINTAIN A CONTINUOUS PATH TO GROUND THROUGHOUT THE ENTIRE LENGTH OF THE RACEWAY. WIRING: 15) UNLESS NOTED OTHERWISE ON THE DRAWINGS OR ON THE EQUIPMENT WIRING SCHEDULE, EACH BRANCH CIRCUIT HOME RUN SHALL BE THREE (3) #12 AWG THHN/THWN (1 HOT, 1 NEUTRAL & 1 EQUIPMENT GROUND) IN 3/4" EMT CONDUIT. PROTECT EACH CIRCUIT , WITH A 20 AMPERE, 1—POLE OVERCURRENT DEVICE UNLESS NOTED OTHERWISE. COMBINED NEUTRALS ARE NOT PERMITTED. WIRE SIZE REQUIRED FOR BRANCH CIRCUITS AT LESS THAN 3% VOLTAGE DROP CALCULATED USING COPPER WIRE AT 75 C. BRANCH CIRCUITS HAVE BEEN CALCULATED FOR SINGLE PHASE VOLTAGE DROP BASED ON SINGLE PHASE CIRCUIT EXISTING DEVICES TO REMAIN: 16) UNLESS OTHERWISE NOTED: a. ON DEMOLITION AND NEW WORK PLANS — DEVICES AND EQUIPMENT SHOWN IN LIGHT LINETYPE ARE EXISTING TO REMAIN. b. ON DEMOLITION PLANS — DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE EXISTING TO BE REMOVED c. ON NEW WORK PLANS — DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE NEW. EN o TE F ( BIS&k awrenc �>,hideth m 7c 1 FT TO 50 FT 51 FT TO 75 FT 76 FT TO 100 FT 101 FT TO 125 FT 126 FT TO 150 FT 151 FT TO 200 FT 120V 20A #12 #10 #8 #8 #6 #6 30A #10 #8 1 #6 #6 1 #6 #4 40A #8 #6 #6 #4 #4 #3 50A #8 #6 #4 #4 #3 #2 208V 1 20A #12 #12 #12 #10 #10 #8 30A #10 #10 #10 #8 #8 #6 40A #8 #8 #8 #8 #6 #6 50A #8 #8 #8 #6 #6 #4 60A #6 #6 #6 #6 #4 #4 70A #4 #4 #4 #4 #4 #3 BOA #4 #4 #4 #4 4 #3 90A #3 #3 #3 #3 #3 #2 100A #3 #3 #3 #3 #3 #2 20A #12 #12 #12 #10 #10 #8 208V 3 30A #10 #10 #10 #8 #8 #6 40A #8 #8 #8 #8 #6 #6 50A #8 8 #8 #6 1 #6 #4 60A #6 #6 #6 #6 #6 #4 70A #4 #4 #4 #4 #4 #4 BOA #4 #4 #4 #4 #4 #3 90A #3 #3 #3 #3 #3 #3 100A 3 3 #3 #3 #3 2 CALCULATED USING COPPER WIRE AT 75 C. BRANCH CIRCUITS HAVE BEEN CALCULATED FOR SINGLE PHASE VOLTAGE DROP BASED ON SINGLE PHASE CIRCUIT EXISTING DEVICES TO REMAIN: 16) UNLESS OTHERWISE NOTED: a. ON DEMOLITION AND NEW WORK PLANS — DEVICES AND EQUIPMENT SHOWN IN LIGHT LINETYPE ARE EXISTING TO REMAIN. b. ON DEMOLITION PLANS — DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE EXISTING TO BE REMOVED c. ON NEW WORK PLANS — DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE NEW. EN o TE F ( BIS&k awrenc �>,hideth m 7c 0 0_ 0 U m ai D a� a~ 0 U N e C C0�0m Lu P. _ 3Ww3� 1 C .0 O a m� U ^� I! Nelson Blankenship, AIA �UF"' xm y W�Q� �w ZUc N aal F+i 4 Cl C. a r--1 U U W Z 4-1 O V1 DRAWN CHECKED MJP/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER E-001 DATE 02-23-18 Floor Plan - Liahtina SCALE: 1/8"=1'-0" Floor Plan - Power and Systems SCALE: 1/8"=1'-0" i GENERAL LIGHTING NOTES: A. _ SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS AND ORIENTATIONS. B. REFER TO ARCHITECTURAL ELEVATIONS AND SECTIONS FOR ADDITIONAL LIGHTING FIXTURE MOUNTING DETAILS AND INFORMATION. C. ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS SHALL BE CONNECTED "HOT" TO THE INDICATED LOCAL LIGHTING CIRCUIT. D. VERIFY ALL MOUNTING HEIGHTS AND PENDANT LENGTHS WITH ARCHITECT AND ENGINEER PRIOR TO ORDERING FIXTURES. E. EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A PERIOD OF 90 MINUTES IN THE EVENT OF FAILURE OF NORMAL LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOTCANDLE (10 LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOTCANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOTCANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOTCANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40:1 SHALL NOT BE EXCEEDED. Mezzanine Floor Plan - Lighting SCALE: 1/8"=1'-0" GENERAL POWER/SYSTEMS NOTES: A. DO NOT SCALE ELECTRICAL DRAWING FOR ANY DIMENSIONS. B. ALL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE, NATIONAL, STATE AND LOCAL CODES. PROVIDE GROUNDING AND BONDING PER NEC 250. C.- SEE SINGLE LINE DIAGRAM FOR FEEDER WIRE AND CONDUIT SIZE. ALL CIRCUITS NOT SIZED ON DRAWING SHALL BE INSTALLED TO MEET MINIMUM SIZE REQUIRED BY NEC. ALL • CONDUCTORS SHALL HAVE AN EQUIPMENT GROUND WIRE SIZED PER NEC. D. FIELD VERIFY EXACT LOCATION OF ALL DEVICES AND EQUIPMENT PRIOR TO ROUGH IN. Mezzanine Floor Plan - Power and Systems SCALE: 1/8"=1'-0" LIGHTING PLAN REFERENCE NOTES: O O1 EXISTING LIGHTING, RECEPTACLES AND EQUIPMENT IN THIS AREA IS EXISTING TO REMAIN. MAINTAIN EXISTING BRANCH CIRCUITS AS REQUIRED. 20 PROVIDE WALL MOUNTED, DUAL TECHNOLOGY, LOW VOLTAGE VACANCY SENSOR, WATTSTOPPER #DW -100-24 (OR APPROVED SUBSTITUTION) FOR AUTOMATIC CONTROL OF LIGHTING. CONNECT LIGHTING IN SPACE AS SHOWN ON PLANS VIA WATTSTOPPER LIGHTING POWER PACK #BZ -200 (OR APPROVED SUBSTITUTION). PROVIDE ALL ADDITIONAL POWER PACKS, RELAYS, SENSORS AS REQUIRED FOR COMPLETE COVERAGE OF SPACE AND SWITCHING AS SHOWN ON PLANS. PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT LIGHTING POWER PACKS WITH RECEPTACLE POWER PACKS IN SPACE FOR AUTOMATIC CONTROL OF RECEPTACLES IF INDICATED ON POWER PLANS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION. O3 PROVIDE CEILING MOUNTED, DUAL TECHNOLOGY, LOW VOLTAGE VACANCY SENSOR, WATTSTOPPER #DT -300 SERIES (OR APPROVED SUBSTITUTION) FOR AUTOMATIC CONTROL OF LIGHTING. CONNECT LIGHTING IN SPACE AS SHOWN ON PLANS VIA WATTSTOPPER LIGHTING POWER PACK #BZ -200 (OR APPROVED SUBSTITUTION). PROVIDE ALL ADDITIONAL POWER PACKS, RELAYS, SENSORS AS REQUIRED FOR COMPLETE COVERAGE OF SPACE AND SWITCHING AS SHOWN ON PLANS. PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT LIGHTING POWER PACKS WITH RECEPTACLE POWER PACKS IN SPACE FOR AUTOMATIC CONTROL OF RECEPTACLES IN INDICATED ON POWER PLANS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION. POWER/SYSTEMS REFERENCE NOTES: O it 10 EXISTING LIGHTING, RECEPTACLES AND EQUIPMENT IN THIS AREA IS EXISTING TO REMAIN. MAINTAIN EXISTING BRANCH CIRCUITS AS REQUIRED. O ELECTRICAL CONTRACTOR SHALL COORDINATE DISCONNECT AND FUSE REQUIREMENTS ,FOR MECHANICAL UNIT WITH MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER PRIOR TO ROUGH -IN AND PROVIDE AS REQUIRED. O3 EXISTING TELEPHONE TERMINAL BLOCKS/EQUIPMENT AND ASSOCIATED RECEPTACLE TO BE RELOCATED AS INDICATED. EXTEND EXISTING INCOMING CONDUIT AND 120VOLT CIRCUIT FOR RECEPTACLE TO NEW LOCATION AS REQUIRED. COORDINATE EXACT REQUIREMENTS WITH OWNER AND TELECOMMUNICATIONS PRIOR TO ROUGH -IN. �4 SCREENED SYMBOLS/EQUIPMENT IS EXISTING TO REMAIN. MAINTAIN EXISTING BRANCH CIRCUIT AS REQUIRED. O CONNECT 120V RECEPTACLE CIRCUIT IN OFFICE SPACE VIA WATTSTOPPER PLUG LOAD POWER PACK #BZ -200 (OR APPROVED SUBSTITUTION) FOR AUTOMATIC CONTROL OF RECEPTACLES. RECEPTACLES SHALL BE SPLIT WIRED SO THAT THE POWER PACK SHALL AUTOMATICALLY "TURN OFF" THE TOP OUTLET ON EACH RECEPTACLE IF SPACE IS UNOCCUPIED FOR 20 MINUTES AND THE BOTTOM OUTLET SHALL BE CONSTANT HOT. OUTLETS SHALL BE VISUALLY MARKED AS REQUIRED TO DIFFERENTIATE CONTROLLED OUTLETS FROM UNCONTROLLED OUTLETS. RECEPTACLE POWER PACKS SHALL BE CONTROLLED VIA LOW VOLTAGE VACANCY SENSORS AS SHOWN ON LIGHTING PLAN. PROVIDE ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED TO INTERCONNECT RECEPTACLE POWER PACKS AND LIGHTING POWER PACKS. INSTALLATION SHALL COMPLY WITH FLORIDA BUILDING CODE SECTION C405.7.1, 2014 EDITION AND ASHRAE STANDARD 90.1. O CONNECT FRACTIONAL HORSEPOWER EXHAUST FAN TO OPERATE WITH OCCUPANCY CONTROLLED LIGHTING ON THIS ROOM. O7 PROVIDE POWER POLE AND 120VOLT CONNECTION FROM ACCESSIBLE CEILING FOR CONNECTION TO OWNER PROVIDED PRE -WIRED TESTING TABLES. COORDINATE EXACT REQUIREMENTS AND LOCATIONS PRIOR TO ROUGH -IN. J �%117!04& REN C s No. 0 0 s SAE0 �. Blat'C� a• u h CD O CL U U a� cz 0 a) 0 a o C a cr aW o?m�0 C O� z V) a O C x a O m� Nelson Blankenship, AIA p.., v1 Q e w �, UN o N r U W p Qw a00 W U�~�^� I� k;l � CC3 k U N 4_4 4° "' U o � QO Q� t N O DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER E-201 DATE 02-23-18 ■ LIGHTING FIXTURE SCHEDULE I MARK DESCRIPTION MANUFACTURER MODEL VOLTS LAMP FIXTURE QTY WATTS MODEL VOLTAGE: MAINS: LUGS: 208Y/120V 30 4W 225A ® MLO [1MCB ❑ SUB -FEED ❑ FEED-THRU MIN. AIC RATING: MOUNTING: ENCLOSURE. WATTS A 2'x4' ARCHITECTURAL LED RECESSED TROFFER, MINIMUM 90 CREE LIGHTING ZR24-40L-35K 120 - - LED 44 CIRCUIT DESCRIPTION CRI 1 EXISTING LTS - 1ST FLR EX EX EX EX 20/1 0.50 A 0.50 20/1 EX B WALL MOUNTED DECORATIVE OVER THE MIRROR VANITY LED MODERN FORMS WS -24727 -AL 120 - - LED 25 1.50 30/2 LUMINAIRE - SOLID CLEAR CURVED ACRYLIC LENS EX EX EX EXISTING - INSTA HOT 4 5 EXISTING HIGH -BAY LTS EX EX C WALL MOUNTED DECORATIVE ADA COMPLIANT WALL SCONCE - MODERN FORMS WS -29 -17 -BN -120 - - LED 26 7 EXISTING - RTU AT MEZZANINE STAIR EX EX EX 40/3 3.46 A 1.08 20/1 EX EX EX EX EXISTING - CIRCUIT WALL MOUNTED EXTERIOR LED LUMINAURE - TYPE 3 s - EX - - - - 3.46 B 0.90 20/1 EX DISTRIBUTION EX EXISTING - CIRCUIT 10 11 - EX - - EM UNIVERSAL MOUNTED EMERGENCY LIGHT WITH THERMOPLASTIC HOUSING, TWIN HEADS AND BATTERY BACKUP LIGHTALARMS LCA-2MRS 120 - - LED 7.5 X1 UNIVERSAL EXIT SIGN WITH THERMOPLASTIC HOUSING, RED LIGHTALARMS QLXN500-EN 120 - - LED - 14 LETTERS & BATTERY BACKUP EX EX EX EX 20/1 1.08 B 1.20 20/1 EX EX EX XE COMBINATION EXIT SIGN & EMERGENCY LIGHT W/ LIGHTALARMS UQLXN500-R-2LD1 N 120 - - LED 7.5 EX THERMOPLASTIC HOUSING, & BATTERY BACKUP EX EXISTING - TTB 18 19 EXISTING - CIRCUIT EX EX EX EX NOTES: 1. ALL FIXTURES AND FINISHES SHALL BE APPROVED BY ARCHITECT/OWNER PRIOR TO ORDERING. 2. ALL FIXTURES SHALL INCLUDE LAMPS. NOTES: 1) DIVISION 16 CONTRACTOR SHALL VERIFY ALL FIXTURE TYPES AND FINISHES WITH OWNER PRIOR TO ORDERING. ```�►ttltlt U1I�! 0 r �� � • \GENS :�� �. e No. 69 •s= .. S AT OF o C Rt P Blak,�11-1 0 uddeth E P.E. #: 69060 tY] c O CL U U (D m ❑ a� 0 U � e c o LLJ >��W� J =C O� n 0WWis V •� H H; Z ^�^ C O Q !F ov Nelson Blankenship, AIA i A -i V1 H ® W v, o UN y W U F { aIL �m U O� a F-•� w U a M �> 0 Pq r. ct U U N U 40, M ¢o A H •� a ct ct ct Q N DRAWNCHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER E-301 DATE 02-23-18 EXISTING PANEL 'A' LOCATION: TENANT SPACE VOLTAGE: MAINS: LUGS: 208Y/120V 30 4W 225A ® MLO [1MCB ❑ SUB -FEED ❑ FEED-THRU MIN. AIC RATING: MOUNTING: ENCLOSURE. EXISTING SURFACE NEMA 1 NOTES: PROVIDE TYPED WRITTEN DIRECTORY PROVIDE GROUND &NEUTRAL BUS TYPE: EXISTING FED FROM: METER SERVICE DISC. F CIRCUIT DESCRIPTION N BRANCH CIRCUIT o z NEU GND COND PHASE BKR LOAD LOAD BKR KVA KVA BRANCH CIRCUIT o 0 NEU GND OND z CIRCUIT DESCRIPTION 1 EXISTING LTS - 1ST FLR EX EX EX EX 20/1 0.50 A 0.50 20/1 EX EX I EX I EX EXISTING - MEZZ OFFICE LTS 2 3 EXISTING RECEPTACLE 1ST FLR EX EX EX EX 20/1 1.08 B 1.50 30/2 EX EX EX EX EXISTING - INSTA HOT 4 5 EXISTING HIGH -BAY LTS EX EX EX EX 20/1 1.25 C 1.50 - EX - - - - s 7 EXISTING - RTU EX EX EX EX 40/3 3.46 A 1.08 20/1 EX EX EX EX EXISTING - CIRCUIT 8 s - EX - - - - 3.46 B 0.90 20/1 EX EX EX EX EXISTING - CIRCUIT 10 11 - EX - - - - 3.46 C 0.54 20/1 EX EX EX EX EXISTING - CIRCUIT 12 13 EXISTING - RECEPTACLE/ROOF EX EX EX EX 1 20/1 0.18 A 1.08 20/1 EX EX EX EX EXISTING - CIRCUIT 14 15 EXISTING - CIRCUIT EX EX EX EX 20/1 1.08 B 1.20 20/1 EX EX EX EX EXISTING - SIGNAGE 16 17 EXISTING - CIRCUIT EX EX EX EX 20/1 0.90 C 0.36 20/1 EX EX EX EX EXISTING - TTB 18 19 EXISTING - CIRCUIT EX EX EX EX 20/1 1.08 A 0.72 20/1 EX EX EX EX EXISTING - CIRCUIT 20 21 EXISTING - BATTERY CHARGER 2 EX EX EX EX 40/2 0.00 B 0.90 20/1 12 12 12 1/2" 1 RECEPTACLE - PARTS/CLEAN/STOR 22 23 - EX - - - - 0.00 C 1.08 20/1 12 12 12 1/2" 1 RECEPTACLE - BATHRM/JAN/EXH. FAN 24 25 - EX - - - - 0.00 A 1.26 20/1 12 12 12 1/2" 1 RECEPTACLE -PROD./BILLING/OFF'S 26 27 RTU -1 1 4 4 8 .25 70/3 5.86 B 1.09 20/1 12 12 12 1/2" 1 LIGHTS - PRODUCT/LOBBY/OFFS 28 291- 4 - - - - 5.86 C 1.06 20/1 12 12 12 1/2"11 LIGHTS - SHIPPING/OFFICES 30 31 - 4 - - - - 5.86 A 1.08 20/1 12 12 12 1/2"11 POWER POLE - TESTING DESK 32 33 INSTA-HOT 1 8 8 10 /4" 35/1 3.00 B 1.08 20/1 12 12 12 1/2- 1 POWER POLE - TESTING DESK 34 35 SPARE 1 - - - - 20/81 - C 1.08 20/1 12 12 12 1/2" 1 POWER POLE - TESTING DESK 36 37 SPARE 1 - - - - 20/81 - A 1.08 20/1 12 12 12 1/2" 1 POWER POLE -TESTING DESK 38 39 SPARL 1 - - - - 20/81 - B - - - - - - SPACE ONLY 40 41 SPARE 1 - - - - 20/81 - C - - - - - - SPACE ONLY 42 EQUIPMENT SERVED CONN. LOAD L.F. I D.F. DEMAND LOAD LIGHTING 5.60 KVA 11257. 7.00 KVA RECEPTACLES - GENERAL 16.56 KVA 100% 16.56 KVA EQUIPMENT 33.96 KVA 100% 33.96 KVA NOTES: 1) PROVIDE NEW C/B IN EXIST. SPACE, MATCH AIC RATING 2) C/B.MADE SPARE DURING DEMOLITION. TOTAL DEMAND LOAD: 57.52 KVA TOTAL DEMAND AMPS: 159.78 AMPS ```�►ttltlt U1I�! 0 r �� � • \GENS :�� �. e No. 69 •s= .. S AT OF o C Rt P Blak,�11-1 0 uddeth E P.E. #: 69060 tY] c O CL U U (D m ❑ a� 0 U � e c o LLJ >��W� J =C O� n 0WWis V •� H H; Z ^�^ C O Q !F ov Nelson Blankenship, AIA i A -i V1 H ® W v, o UN y W U F { aIL �m U O� a F-•� w U a M �> 0 Pq r. ct U U N U 40, M ¢o A H •� a ct ct ct Q N DRAWNCHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER E-301 DATE 02-23-18 --------------- 1rst� STRIP IN TIETEX #272 CAULK PERIMETER W/ FLEX STITCHBOND POLYESTER SEAL SEBS (WHITE) (FABRIC WT. = 3 OZ.) SEE NOTES BELOW. 24 GA. GALV. STEEL FLASHING r 12" MIN. 201, 8" MIN. 16" - ROOF -j - _j / 4 - I 1/2" CLEAR SET IRON JACK IN BED OF FLEX SEAL CONDUIT NOTES: 1. ALL SURFACES TO BE CLEAN (FREE OF DIRT, GREASE, SCALE, PAINT, ETC.) ' 2. WIRE BRUSH ALL LOOSE MATERIAL AS REQUIRED. 3. PRIME EXISTING ROOF AND FLASHING W/ SB ELASTOMERIC PRIMER. 4. 5 COURSE: 2 PLYS TIETEX W/ SB ELASTOMERIC GEL (FEATHER SECOND PLY) AT MIN. 40 MIL UNCURED PER COURSE. 5. TOP COAT W/ K-2 EXTREME DUTY ELASTOMER (MATCH ROOF COLOR) 6. DETAIL SHOW FOR WEATHERPROOFING PENETRATION ONLY. CONTRACTOR SHALL PROVIDE FIRESTOPPING AS REQUIRED TO MAINTAIN FIRE RATING OF ROOF. ONOOF PENETDNAT�ON WEATHERPROOF DETAL 4 SCALE: NTS UL1cUL SYSTEM NO. W-J-1020 ULIcUL SYSTEM NO. W-L-1175 METAL PIPE THROUGH CONCRETE WALL OR BLOCK WALL METAL PIPE THROUGH GYPSUM WALL ASSEMBLY Firestop Putty Pad F-RATING = 2-HR. F-RATING =1-HR. OR 2-HR. o (CP 617, CP 617L and CP 617XL) T-RATING = 0-HR. OR 114-HR. T-RATING = 0-HR. L-RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. L-RATING AT AMBIENT =1 CFMISQ. FT. Product description L-RATING AT 400°F = 4 CFMISQ. FT, a L-RATING AT 400°F =1 CFMISQ. FT. W A moldable firestop putty designed to help protect electrical outlet --r Product features boxes 17 FRONT VIEW SECTION A-A FRONT VIEW SECTION A-A Applied by hand A 6 Fast installation 1 11 A 1 2 Areas of application 11 0 Protection of electrical outlet boxes For use with 4 11 Gypsum wall assemblies with wood or metal studs 2 Examples Technical Data* CP 617 - 3 4 0 Where two outlets are within a single stud/cavity or within 24" Dimensions (LxWxH) CP 617:6" x 7"x 1/8"(15 x 18 x 0.3 cm) measured horizontally (not back to back unless specified by the CP 617X - x 9 x 1/8" (18 x 13x 0.3 cm) specific UL approval) CP 617XL 9° x s' x 1/8" (23 x 23 x 0.3 cm) Consistency Moldable putty .. �. _ Color Red 1,4 Application temperature 40°F (5'C) to 95°F (351G) Storage temperature 40°F (5'C) to 104°F (40°C) Curing time Non-curing Density 1.48 g/cm2 Intumescent activation Approx. 220°F to 250°F (104°C to 121 °C) Volatile solvents None n 5 Asbestos fibers None Surface burning characteristics Flame Spread: 15 A (ASTM E 84-96) Smoke development: 10 Sound transmission classification 59 (Relates to specific construction) (ASTM E 90-97) Tested in accordance with • UL 263 • ASTM E 84 • ASTM G21 1. CONCRETE WALL ASSEMBLY (2-HR. FIRE-RATING): A At73'F(23'C)and 50%relative humidity - A. LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE WALL (MIN. 5" THICK). B. ANY UUULC CLASSIFIED CONCRETE BLOCK WALL. w""OPENING RP TECTNE FM _ 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: - - - c uL us FIRE SEE ESISTANCE PRODUCTCALTEGORYINN APPROVED A. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE. 1. GYPSUM WALL ASSEMBLY (ULIcUL CLASSIFIED 0300 OR U400 SERIES) (1-HR. OR 2-HR. FIRE-RATING) rn UI PARE RESISTANCE eolREcroRr B. MAXIMUM 4" NOMINAL DIAMETER STEEL CONDUIT. - - - - - (2-HR. SHOWN). Cn C. MAXIMUM 4" NOMINAL DIAMETER EMT. 2. [NOT SHOWN] WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM Installation instructions for CP 617 3. MINERAL WOOL (MIN. 4 PCF DENSITY), BACKER ROD, OR HILTI CF 128 FILLER FOAM Notice - stud) and completely seal against the stud within the Not for use WIDE- • Before handling, read Material Safety Data Sheet and stud cavity. In areas exposed to water TO BE USED AS A BACKER. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: 1.4 product label for safe usage and health information. 3. Reshape CP 617 to fit around conduit or cables. Storage - 4. HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT: A. MAXIMUM 4" NOMINAL DIAMETER EMT. 40 1 • Instructions below are general guidelines - always 4. Press CP 617 to all sides of electrical box. Store only In the original packaging Ina location at " „ ct - - - refer to the applicablelisting(CLIV)intheULFire 5. Remove other side of label. temperatures 401F(51C)to1041F(401C) A. MINIMUM 1/4 DEPTH WHEN EMT OR STEEL CONDUIT IS THE PENETRATING ITEM. B. MAXIMUM 4" NOMINAL DIAMETER STEEL CONDUIT.Res_ forcoanceDirectoryoni f rmatiFirestopSystemsGuide - B. MINIMUM 1/2" DEPTH WHEN COPPER PIPE IS THE PENETRATING ITEM. 4. MINIMUM 518" DEPTH HILTI CP 618 FIRESTOP PUTTY STICK. - - - - for complete installation information. _ - _ Application of Firestop putty I-` 5. MINIMUM 114" CROWN HILTI CP 618 FIRESTOP PUTTY STICK AT POINT OF CONTACT. - - - 1. After ensuring box is cleaned of loose debris, dirt,- oil, moisture, frost and wax, remove label from one t NOTES :1. MAXIMUM DIAMETER OF OPENING = 8". side of pad. For a 1 to 2 hour fire rating, one 0 j - CP 617 pad isrequlred. Exposed side of pad Is _ ! x �l;t- ' ' ` -=' Ago �Y 2. ANNULAR SPACE = MINIMUM 3/4", MAXIMUM 3-1/2". - _ NOTES: 1. MAXIMUM DIAMETER OF OPENING 5-1/2- placed against box. - xf " '� I 3. FOR HOLLOW BLOCK WALLS USE NO.8 STEEL WIRE MESH TO AID IN THE INSTALLATION. 2. ANNULAR SPACE = MINIMUM 0" MAXIMUM 1". 2. CP 617 Firestop Putty Pads are to be installed to J J completely cover the exterior surfaces of the outlet t. Rh ove label from one 2. Adhere CP 617 to 3. Reshape CP 617 to fit 4. Press CP 6171,` all S. Remove other.b. - - - - - - - box (except for the side of the outlet box against the tide of CP 617 adlet tmx around box Md..1 _ti'A boa of w1i - - - - - � Sheaf 1 of 1 Dr�apwfnng No. Sheaf 1 of 1 Drawing No. Hilt; Firestop D=:20E=HF0 HILTI, Inc. Scale 118" =1" WJ HILTI, Ind. Scale 3116" =1" WL Saving lives Tulsa, Oklahoma USA (918) 252-6000 Tulsa, Oklahoma USA (918) 252-6000 7 /� through innovation FIRESTOP SYSTEMS Date OZ Hilti Firestop Systems Date Mar. 22, 2006 CC ! and education SEPT. 16, 1999 � Qe p y � � / Jb Hilti. Outperform. outlast. Saving Lives through Innovation and Education Saving Lives through Innovation and Education Hilti, Inc. (U.S.)1-800-879-8000 • www.us.hilti.com • an espanol 1-800-879-5000 • Hilti Firestop Systems Guide OUTLET BOX MOUNTED N RA"E DATE® WALL UL FORE RATED DETAL (W-J-1020) UL FRE RATED DETAL (W-L-1175) .♦........ 3SCALE: NTS 2 SCALE: NTS SCALE: NTS :� GEN F'•.�0�'� a -A . - ~ ♦ �. •♦ S E e. Blak�te� Ir p$,i��deth P. _ 9060 m c 0 Q U s Q) m c 0 Q U Q) N 0 a� 0 U � e � a o •C ,nO�OM1 c W V IT oz-�0 3 QVPL,N z � c =2 0 Nelson Blankenship, AIA o � N � W � ° U " W � Q z � /�-•yy�� � � o U �Q U H V.J./ � � �lJ DRAWN CHECKED MJR/KCM BLS/AM PROJECT NUMBER 1716 DRAWING NUMBER E - 4.01 - DATE 02-23-18 ELECTRICAL SPECIFICATIONS REN CE E'�•'�©c�, *� • 0. E0 BlalCaw' th F77 I. GENERAL REQUIREMENTS: J. THE ELECTRICAL CIRCUITS, COMPONENTS, AND CONTROLS FOR ALL EQUIPMENT ARE SELECTED AND F. MOUNTING HEIGHTS ARE APPROXIMATE. THE EXACT LOCATIONS AND MOUNTING HEIGHTS SHALL BE B. ALL GROUNDING CONNECTIONS SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND REQUIREMENTS. SUCH CODES SHALL BE CONSIDERED SIZED, BASED ON THE EQUIPMENT SPECIFIED. IF SUBSTITUTIONS AND/OR EQUIVALENT EQUIPMENT ARE DETERMINED ON THE JOB AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH MINIMUM REQUIREMENTS AND THE INSTALLATION OF THE GROUNDING SYSTEM A. DO ALL WORK IN COMPLIANCE WITH THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING FURNISHED, IT SHALL BE THE RESPONSIBILITY OF ALL PARTIES CONCERNED, INVOLVED IN, AND ALL TRADES TO INSURE CORRECT INSTALLATION, I.E., OVER COUNTERS IN OR ABOVE BACK -SPLASHES, SHALL INSURE FREEDOM FROM DANGEROUS SHOCK EXPOSURE AND SHALL PROVIDE A LOW CODE (FBC-2017), NFPA 70 (NEC -2014) AND NFPA 101 (LIFE SAFETY CODE -2015), FURNISHING THE SUBSTITUTE AND/OR EQUIVALENT EQUIPMENT TO VERIFY AND COMPARE THE IN BLOCK WALLS, TILE, AND OTHER SPECIFIC CONSTRUCTION FEATURES. LOCATION OF OUTLETS IMPEDANCE GROUND FAULT PATH TO PERMIT OPERATION OF OVERCURRENT AND GROUND FAULT AND THE REGULATIONS OF THE LOCAL UTILITY TELEPHONE, CABLE TELEVISION AND POWER UTILITY ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF THAT FURNISHED TO THAT SPECIFIED AND/OR MOUNTED IN BUILT-INS; MILLWORK, AND CABINETRY SHALL'BE VERIFIED. OUTLETS MOUNTED IN KICK PROTECTIVE DEVICES. COMPANIES. OBTAIN AND PAY FOR ANY AND ALL REQUIRED PERMITS, INSPECTIONS, SHOWN. IF GREATER CAPACITY OR MORE MATERIALS OR LABOR IS REQUIRED FOR THE ROUGH -IN, OR TOE SPACES SHALL BE MOUNTED HORIZONTALLY. OUTLET BOXES SHALL BE MOUNTED TO CERTIFICATES OF INSPECTIONS AND APPROVAL, AND THE LIKE, AND DELIVER SUCH CERTIFICATES CIRCUITRY OR CONNECTIONS THAN FOR THE ITEM SPECIFIED AND PROVIDED FOR, THEN IT SHALL BE PREVENT DEVICE PLATE FROM OVERLAPPING BACKSPLASH, TRIM, TILE, ETC. LOCATE SO DEVICE PLATE C. ALL SERVICE AND EQUIPMENT GROUNDING CONDUCTORS, AND BONDING JUMPERS SHALL BE TO THE ENGINEER. THE RESPONSIBILITY OF THE PARTIES INVOLVED IN PROVIDING THE SUBSTITUTE AND/OR EQUIVALENT WILL LAY FLAT AGAINST SURFACE COMPLETELY AROUND THE PERIMETER OF PLATE. INSULATED COPPER, TYPE THHN, THWN, OR THW CONDUCTORS (UNLESS NOTED OTHERWISE) AND B. THE CONTRACTOR SHALL FURNISH, PERFORM, OR OTHERWISE PROVIDE ALL LABOR (INCLUDING, ITEMS OF EQUIPMENT TO PROVIDE ALL COMPENSATION FOR ADDITIONAL CHARGES MADE FOR THE PROPER ROUGH -IN, CIRCUITRY AND CONNECTIONS FOR THE EQUIPMENT FURNISHED. NO ADDITIONAL G. OUTLETS, OTHER THAN THOSE COORDINATED WITH COUNTER TOPS, SHELVES, AND CABINETS, SHALL BE SIZED IN ACCORDANCE WITH THE APPLICABLE PORTIONS OF ARTICLES 250 AND 517 OF THE NATIONAL ELECTRICAL CODE. GROUNDING CONDUCTORS #6 AWG AND SMALLER SHALL HAVE A BUT NOT LIMITED TO, ALL PLANNING, PURCHASING, PAINTING, TRANSPORTING, RIGGING, HOISTING, CHARGES ABOVE THE BASE BID SHALL BE ALLOWED FOR SUCH REVISIONS. SHALL BE LOCATED WITH THE CENTER LINE OF OUTLET BOXES THE FOLLOWING DISTANCE ABOVE THE GREEN COLOR INSULATION. ALL GROUNDING CONDUCTORS #4 AWG AND LARGER SHALL BE STORING, INSTALLING, TESTING, CHASING, CHANNELING, CUTTING, TRENCHING, EXCAVATING AND FINISHED FLOOR, UNLESS OTHERWISE INDICATED: ADEQUATELY IDENTIFIED WITH A GREEN TRACER AND/OR GREEN COLORED TAPE AT EACH END OF BACKFILLING), COORDINATION, FIELD VERIFICATION, EQUIPMENT INSTALLATION, SUPPORT, AND SAFETY, SUPPLIES, AND MATERIALS NECESSARY FOR THE CORRECT INSTALLATION OF COMPLETE K. EXCAVATION FOR UNDERGROUND ELECTRICAL STRUCTURES: CONFORM TO ELEVATIONS AND DIMENSIONS SHOWN WITHIN A TOLERANCE OF PLUS OR MINUS 0.10% PLUS A SUFFICIENT 1. RECEPTACLES, GENERAL: 1'-6" AFF THE GROUNDING CONDUCTOR AND AT EACH PULLBOX OR OTHER ACCESSIBLE LOCATION. AND FUNCTIONAL ELECTRICAL SYSTEMS (AS DESCRIBED OR IMPLIED BY THESE SPECIFICATIONS DISTANCE TO PERMIT PLACING AND REMOVAL OF CONCRETE FORMWORK, INSTALLATION OF 2. TELEPHONE OUTLETS: 1'-6" AFF D. THE MAIN SERVICE GROUNDING ELECTRODE SYSTEM SHALL CONSIST OF THE FOLLOWING ITEMS AND THE APPLICABLE DRAWINGS). SERVICES, OTHER CONSTRUCTION, AND FOR INSPECTION. 3. SWITCHES, GENERAL: 4'-0" AFF BONDED TOGETHER BY THE GROUNDING ELECTRODE CONDUCTORS IN ACCORDANCE WITH NEC ARTICLE C. ALL DRAWINGS AND SPECIFICATIONS ON THE PROJECT ARE COMPLEMENTARY, EACH TO ALL OTHER L TRENCHING: EXCAVATE TRENCHES FOR ELECTRICAL INSTALLATIONS AS FOLLOWS: V. RACEWAYS 250, PART H: SETS, AND THEY SHALL BE USED IN COMBINATION FOR THE EXECUTION OF THIS WORK. DIVISION 16 WORK SHOWN ON ANY ONE SET OF DRAWINGS, INCLUDING ALL ARCHITECTURAL 1. EXCAVATE TRENCHES TO THE UNIFORM WIDTH, SUFFICIENTLY WIDE TO PROVIDE AMPLE A SHALL BE GALVANIZED OUTSIDE AND INSIDE BY HOT DIPPING. E.M.T. SHALL BE ELECTRO - 1. THE MAIN UNDERGROUND COLD WATER PIPE, IF METAL, NEC 250- 81(A) FRAME OF BUILDING WHERE AVAILABLE, NEC 250-81(B) DRAWINGS, MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWINGS FOR GENERAL WORK AND WORKING ROOM AND A MINIMUM OF 6" TO 9" CLEARANCE ON BOTH SIDES OF RACEWAYS GALVANIZED. CONDUITS SHALL BE AS MANUFACTURED BY REPUBLIC, PITTSBURGH STANDARD, 2. METAL CONCRETE ENCASED ELECTRODE, NEC 250-81(C) EQUIPMENT, AND DIVISION 16 WORK CALLED FOR UNDER ANY SECTION OF THE PROJECT AND EQUIPMENT. WHEATLAND, TRIANGLE, ALLIED, OR YOUNGSTOWN. 3. SPECIFICATIONS, SHALL BE CONSIDERED AS INCLUDED IN THIS WORK UNLESS SPECIFICALLY 2. EXCAVATE TRENCHES TO DEPTH INDICATED OR REQUIRED. 4. THE BUILDING LIGHTNING PROTECTION SYSTEM. EXCLUDED BY INCLUSION IN SOME OTHER BRANCH OF THE WORK. THIS SHALL INCLUDE 3. LIMIT THE LENGTH OF OPEN TRENCH TO THAT IN WHICH INSTALLATIONS CAN BE MADE AND B. SHALL BE STANDARD THREADED TYPE, GALVANIZED OUTSIDE AND INSIDE BY HOT DIPPING. U�Q v aHM� 0 ROUGHING -IN FOR CONNECTIONS AND EQUIPMENT AS CALLED FOR OR INFERRED. THE THE TRENCH BACKFILLED WITHIN THE SAME DAY. THREADLESS AND CLAMP TYPE NOT ACCEPTABLE. SHALL BE AS MANUFACTURED BY RACO, E. THE NEUTRAL CONDUCTOR SHALL BE GROUNDED AT THE SERVICE ENTRANCE MAIN DISCONNECT, CONTRACTOR SHALL CHECK ALL DRAWINGS AND SPECIFICATIONS FOR THE PROJECT AND SHALL BE 4. WHERE ROCK IS ENCOUNTERED, CARRY EXCAVATION BELOW REQUIRED ELEVATION AND EFCOR, OR APPLETON. AND AT EACH SEPARATELY DERIVED SYSTEM ONLY PER NEC ARTICLE 250. RESPONSIBLE FOR THE INSTALLATION OF ALL DIVISION 16 WORK. BACKFILL WITH A LAYER OF CRUSHED STONE OR GRAVEL PRIOR TO INSTALLATION OF RACEWAYS AND EQUIPMENT. PROVIDE A MINIMUM OF 6" OF STONE OR GRAVEL CUSHION C. SHALL BE STEEL THREADED COMPRESSION TYPE. ALL COUPLINGS AND CONNECTORS SHALL BE F. A4 INSULATED COPPER CONDUCTOR INSTALLED IN 3/4- CONCEALED CONDUIT SHALL BE # / D. THE CONTRACTOR SHALL CAREFULLY CHECK THE DRAWINGS AND SPECIFICATIONS OF ALL OTHER BETWEEN ROCK BEARING SURFACE AND ELECTRICAL INSTALLATIONS. EFCOR OR RACO. PRESSURE INDENTED TYPE CONNECTORS OR CAST METAL WILL NOT BE APPROVED CONNECTED FROM THE BUILDING GROUNDING ELECTRODE SYSTEM TO EACH BUILDING TELEPHONE TRADES AND DIVISIONS BEFORE INSTALLING ANY OF HIS WORK. HE SHALL IN ALL CASES FOR ANY LOCATION. TERMINAL/DATA IDF TERMINAL BOARDS, OR CABINETS, FIRE ALARM CONTROL CABINETS, CCN SYSTEM CONSIDER THE WORK OF ALL OTHER TRADES, AND SHALL COORDINATE HIS WORK WITH THEM SO M. THE CONTRACTOR SHALL PROVIDE ALL INSERTS FOR THE SUPPORT OF DIVISION 16 CABINETS, EMS CABINETS, AND SECURITY SYSTEM CABINETS. TERMINATE ON AN APPROPRIATELY SIZED THAT THE BEST ARRANGEMENTS OF ALL EQUIPMENT, PIPING, CONDUIT, DUCTS, ROUGH -IN, ETC., EQUIPMENT TO BE PLACED IN CONCRETE OR THROUGH CONCRETE SLABS AS CONSTRUCTION D. CONNECTORS SHALL HAVE PLASTIC INSULATED THROAT INSERTS. (8) TERMINAL MULTI -CONDUCTOR CONNECTION GROUNDING LUG LOCATED WITHIN CABINET OR ON CAN BE OBTAINED. PROGRESSES. HE SHALL PROVIDE ALL MISCELLANEOUS HANGING AND SUPPORTING HARDWARE. ALL E. THE USE OF METAL CLAD CABLE IS ACCEPTABLE IN LOCATIONS AS ACCEPTED BY THE NEC AND TERMINAL BOARDS. O ELECTRICAL WORK IS TO BE CONCEALED IN OR BUILT INTO GENERAL CONSTRUCTION SHALL BE E. LOCATIONS DESIGNATED FOR OUTLETS, SWITCHES, DEVICES, EQUIPMENT, ETC., ARE PLACED AS CONSTRUCTION PROGRESSES. FAILURE OF THE CONTRACTOR TO COORDINATE WORK WITH ALL LOCAL JURISDICTIONAL CODES. IX, PANELBOARDS: APPROXIMATE AND FINAL LOCATIONS SHALL BE VERIFIED IN THE FIELD. CONTRACTOR SHALL OTHER TRADES AND THE PROJECT CONSTRUCTION PROGRESS SHALL MAKE HIM RESPONSIBLE FOR LOCATE ALL DEVICES UP TO 5 FEET IN ANY DIRECTION AS DIRECTED BY OWNER AND PER CODE. ALL COST OF CUTTING AND PATCHING, AS REQUIRED TO INSTALL WORK. NO STRUCTURAL MEMBER, F. STEEL METAL CLAD CABLE, TYPE MC, EMPLOYING CIRCUIT CONDUCTORS #12 SOLID TO #2 AWG, A. PANELBOARDS SHALL BE DEAD FRONT TYPE AND SHALL BE IN ACCORDANCE WITH UNDERWRITERS' WHERE INSTRUCTIONS OR NOTES ARE INSUFFICIENT TO CONVEY THE INTENT OF THE DESIGN, MASONRY CONSTRUCTION OR FINISHED WORK SHALL BE CUT OR ALTERED WITHOUT PRIOR WRITTEN SOLID OR STRANDED COPPER WITH THHN INSULATION, AN INSULATED GREEN GROUNDING CONDUCTOR LABORATORIES, INC., STANDARD FOR PANELBOARDS AND ENCLOSING CABINETS AND SO LABELED. CONSULT THE OWNER PRIOR TO BIDDING AND INSTALLATION. APPROVAL BY THE ARCHITECT/ENGINEER. CONTRACTOR SHALL FIRE RATE ALL PENETRATIONS THROUGH AND GALVANIZED STEEL INTERLOCKED ARMOR CLADDING. THE CABLES SHALL BE SUITABLE FOR USE DRAWN CHECKED ALL FIRE RATED SLABS OR WALLS PER THE INTENDED RATING. IN DRY LOCATIONS AT TEMPERATURES NOT EXCEEDING 90' C ON AD CIRCUITS UP TO 600 VOLTS IN B. PANELBOARDS SHALL BE FACTORY ASSEMBLED WITH BRANCH BREAKERS ARRANGED AS SHOWN IN F. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING AND COORDINATING THE LOCATIONS OF ACCORDANCE WITH N.E.C., ARTICLE 334. THE CABLE SHALL BE ONE AND TWO HOUR FIRE RATED PER SCHEDULES. BREAKERS SHALL BE NUMBERED VERTICALLY BEGINNING TOP LEFT. BREAKER NUMBERS DEVICES TO BE USED AND COORDINATING THE FINAL LOCATIONS OF ELECTRICAL EQUIPMENT WITH N. THE CONTRACTOR SHALL SUPPLY AND SET INTO PLACE ALL WALL SLEEVES FOR CONDUITS ANSI/UL 1479 FOR USE IN WALL, CEILING AND FLOOR ASSEMBLIES. SHALL BE PERMANENTLY ATTACHED TO TRIM. PANEL SHALL BE MINIMUM 20" WIDE OR 16" FOR MILLWORK, SINKS, BENCHES, COUNTERS AND SHELVING PRIOR TO BIDDING AND INSTALLATION. AND CEILING INSERTS FOR HANGERS IN AREAS OF NEW CONSTRUCTION AS BUILDING CONSTRUCTION 02-23-18 RESIDENTIAL LOAD CENTERS, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. PROGRESSES. INSTALL EQUIPMENT NOTED TO BE CONCEALED IN WALLS BEFORE WALLS ARE G. FLEXIBLE METALLIC CONDUIT RACEWAYS MAY BE USED TO CONNECT HVAC UNITS LOCATED IN CONSTRUCTED IN ORDER THAT WALLS MAY BE CONSTRUCTED AROUND CONDUITS, ENCLOSURES, ETC. INTERIOR MECHANICAL AREAS. MINIMUM SIZE 3/4". C. ANY SPECIAL REQUIREMENTS ON THE DRAWINGS OR SCHEDULES, SUCH AS GROUND FAULT G. DIVISION 16 CONTRACTOR SHALL HAVE HAD EXPERIENCE OF AT LEAST THE SAME SIZE AND PROTECTION, ARC -FAULT CIRCUIT BREAKERS, INCREASED INTERRUPTING CAPACITY, SHUNT TRIP TYPE SCOPE AS THIS PROJECT, ON AT LEAST TWO OTHER PROJECTS WITHIN THE LAST FIVE YEARS IN 0. METALLIC MATERIALS SHALL BE PROTECTED AGAINST CORROSION. EQUIPMENT ENCLOSURES SHALL H. CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL CODE EXCEPT CIRCUIT BREAKER, FEED THRU PANELBOARDS, ETC., SHALL SUPERSEDE THESE SPECIFICATIONS, BUT ORDER TO BE QUALIFIED TO BID THIS PROJECT. BE GIVEN RUST -INHIBITING TREATMENT AND STANDARD FINISH BY MANUFACTURER. ALUMINUM SHALL THAT NO CONDUIT SHALL BE SMALLER THAN 3/4" UNLESS OTHERWISE NOTED. CONDUIT SHALL BE ONLY INSOFAR AS THAT PARTICULAR REQUIREMENT IS CONCERNED AND AS INDICATED. NOT BE USED ON CONTACT WITH EARTH, AND, WHERE CONNECTED TO DISSIMILAR METAL, SHALL BE SIZED LARGER THAN REQUIRED ABOVE WHEN SO SHOWN ON THE DRAWINGS OR WHEN REQUIRED BY H. CONTRACTOR SHALL AND DOES HEREBY WARRANT ALL MATERIALS AND EQUIPMENT FURNISHED PROTECTED BY SUITABLE FITTINGS AND TREATMENT. ALL FERROUS METALS SUCH AS ANCHORS, LOCAL CODE. D. WIRING IN PANELBOARD GUTTERS SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. WIRING UNDER THIS SECTION OF THE SPECIFICATIONS TO BE FREE FROM DEFECTS AND TO FUNCTION OR BOLTS, BRACES, BOXES, BODIES, CLAMPS, FITTINGS, GUARDS, NUTS, PINS, RODS, SHIMS, THIMBLES, SHALL BE GROUPED INTO NEAT BUNDLES AND SECURED WITH NYLON TIE WRAPS. OPERATE SATISFACTORILY FOR ONE YEAR AFTER FINAL ACCEPTANCE OF THE WORK, AND THAT ANY WASHERS, AND MISCELLANEOUS PARTS, NOT OF STAINLESS STEEL OR NONFERROUS MATERIALS, I. ANY CONDUIT STUBBED OUT FOR FUTURE SHALL BE CAPPED WITH A PLASTIC CAP AND MARKED ITEMS NOT MEETING THIS REQUIREMENT WILL BE MADE GOOD BY HIM WITHOUT COST TO OWNER, PROVIDED SUCH DEFECTS OR FAILURES ARE NOT DUE TO ABUSE, NEGLECT, OR LACK OF SHALL BE HOT -DIPPED GALVANIZED. WITH A 2" MINIMUM RED METAL TAG WHICH IDENTIFIES CONDUIT ORIGIN. CONDUITS STUBBED UP E. PROVIDE TYPE WRITTEN DIRECTORIES FOR EACH PANELBOARD INDICATING THE LOAD SERVED. REASONABLE AND ORDINARY MAINTENANCE. ABOVE GRADE OR ROOF SHALL BE TAGGED ON THE CONDUIT. CONDUIT STUBBED OUT BELOW GRADE P. ALL CONDUITS STUBBED OUT FOR FUTURE USE SHALL HAVE A PULL WIRE INSTALLED, A PLASTIC SHALL BE TAGGED ON NEAREST BUILDING WALL, CURB, ETC., DIRECTLY OVER THE CONDUIT RUN. ALL X. LIGHTING FIXTURES: I. ALL WORK SHALL BE EXECUTED IN A WORKMANSHIP MANNER DISPLAYING A NEAT CAP INSTALLED AND BE IDENTIFIED AS TO THE CONDUIT ORIGIN. EMPTY CONDUITS SHALL HAVE PULL WIRES. A. LIGHTING FIXTURES SHALL BE FURNISHED AS SHOWN ON DRAWINGS AND IN THE LIGHTING MECHANICAL APPEARANCE UPON COMPLETION. Q. THE RESPONSIBILITY FOR ANY CUTTING OF CONSTRUCTION WHICH IS REQUIRED FOR THE VI. SCHEDULE 40 RIGID PVC: FIXTURE SCHEDULE. IT SHALL SPECIFICALLY BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY J. BALANCE TOTAL PHASE LOADS IN EACH ELECTRICAL PANEL TO A VALUE WITHIN 10% OF EACH INSTALLATION OF DIVISION 16 WORK, SHALL BE BY THE CONTRACTOR. THE CONTRACTOR SHALL EXACT TYPE CEILING AND RECESSING DEPTH OF ALL RECESSED FIXTURES AND TO FURNISH THE COORDINATE WITH ALL OTHER TRADES AND THE OWNER BEFORE ANY CUTTING AND OBTAIN APPROVAL A. CONDUIT SHALL BE COMPOSED OF POLYVINYLCHLORIDE AND SHALL BE UL RATED TYPE 40 FOR MOUNTING TRIMS AND ACCESSORIES OF THE SPECIFIED AND/OR APPROVED FIXTURES FOR THE OTHER. FROM THE ARCHITECT/ENGINEER PRIOR TO ANY CUTTING. ALL PATCHING AND FINISHING SHALL BE BY USE WITH 90EC RATED CONDUCTORS. CONDUIT SHALL CONFORM TO NEMA STANDARDS AND CEILING TO BE INSTALLED. LIGHTING FIXTURES SHALL BE PROVIDED WITH JOINER PLATES, END CAPS, K. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION, WHEREVER WORK IS TO BE THE CONTRACTOR. APPLICABLE SECTIONS OF NEC. RETAINING CLIPS, PLASTER FRAMES, HOUSINGS, AND ALL OTHER ACCESSORIES REQUIRED FOR A PERFORMED IN FINISHED OCCUPIED SPACES, TO PREVENT DAMAGE TO ADJACENT AREAS, / R. WHERE OPENINGS OR HOLES ARE CUT IN CONSTRUCTION AND THE CUTTING BREAKS ELECTRICAL B. INSTALLATION OF RIGID NON-METALLIC CONDUIT SHALL COMPLY WITH ARTICLE 347 OF THE COMPLETE INSTALLATION. EQUIPMENT, OR FURNISHINGS; TO PREVENT ACCIDENTAL INJURY TO BUILDING OCCUPANTS AND FROM THE CIRCUITRY OR CONTROL CIRCUITRY CONDUIT AND WIRING, THEN IT SHALL BE THE RESPONSIBILITY OF NATIONAL ELECTRICAL CODE (NFPA 70) AND THESE SPECIFICATIONS. B. ALL FIXTURES SHALL BE EQUIPPED WITH LAMPS UNLESS OTHERWISE NOTED. LAMPS SHALL BE THE PUBLIC; TO PREVENT THE SPREADING OF DUST, DIRT, DEBRIS, AND MOISTURE THE CONTRACTOR TO REROUTE THE CIRCUITRY CONDUIT AND REWIRING AND TO COMPLETE THE INSTALLED NEW, IMMEDIATELY PRIOR TO FINAL INSPECTION, AND SHALL NOT BE USED FOR AREA WHERE WORK IS BEING PERFORMED; AND TO PREVENT DUST, DIRT, DEBRIS, AND CIRCUITRY AS REQUIRED AND AS APPROVED BY THE ARCHITECT/ENGINEER. TEMPORARY COMPLETION C. PROVIDE A CONTINUOUS, INSULATED, GROUNDING CONDUCTOR IN EVERY RIGID, NON-METALLIC CONSTRUCTION. MOISTURE FROM GETTING ON OR IN THE BUILDING OCCUPANT'S FURNISHINGS OR EQUIPMENT. SHALL BE PROVIDED WHERE NECESSARY BEFORE THE PERMANENT REROUTING AND COMPLETION RACEWAY EVEN IF NOT SHOWN ON THE DRAWINGS. THE GROUNDING CONDUCTOR SHALL BE L THE CONTRACTOR SHALL REPAIR, AT NO COST TO THE OWNER, ANY DAMAGE DONE BY HIMSELF WORK IS FINISHED. CONNECTED TO GROUND AT EACH END OF THE RACEWAY IN ACCORDANCE WITH ARTICLE 250 OF C. FIXTURE CATALOG NUMBER REPRESENTS BASIC LUMINARY SIZE, TYPE, QUALITY AND OR HIS EMPLOYEES. HE SHALL ALSO BE RESPONSIBLE FOR ALL CUTTING AND PATCHING THE NATIONAL ELECTRICAL CODE (NFPA 70). CONFIGURATION. ACCESSORIES SHALL BE FURNISHED WITH EACH UNIT AS REQUIRED FOR A COMPLETE REQUIRED TO PROPERLY INSTALL HIS WORK. THIS SHALL ALSO INCLUDE THE PATCHING OF EXISTING S. ANY PENETRATIONS OF FIRE OR SMOKE RATED ASSEMBLIES MADE BY THIS CONTRACTOR IN FINISHED INSTALLATION. BASIC ACCESSORIES SHALL INCLUDE, BUT ARE` NOT LIMITED TO, THE VERTICAL OR HORIZONTAL CONSTRUCTION SHALL BE SEALED AND PROTECTED BY THIS CONTRACTOR D. WHERE RIGID NON-METALLIC CONDUIT TRANSITIONS TO METALLIC CONDUIT, THE LOCATION OF THE FOLLOWING: ROADWAYS (PAVED OR IMPROVED), PARKING AREAS, SIDEWALKS, WALLS, STAIRS, MECHANICAL IN ORDER TO MAINTAIN THE ESTABLISHED FIRE RATING WITH METHODS AS APPROVED BY THE TRANSITION SHALL BE UNDERGROUND. ' WORK, CURBS, GUTTERS, ETC., CUT TO INSTALL WORK PROVIDED BY THE CONTRACTOR. PATCH AUTHORITY HAVING JURISDICTION. 1. JOINING PLATES, END CAPS, RETAINING CLIPS, ETC. WORK SHALL COMPLY WITH THE APPLICABLE SECTIONS OF THESE SPECIFICATIONS AND SHALL E. NO PVC CONDUIT SHALL BE RUN EXPOSED, OR ABOVE GRADE. 2. TRIMS FOR RECESSED FIXTURES. MATCH THE EXISTING FINISHES. III. IDENTIFICATION: 3. FIXTURE STEMS AND CANOPIES FINISHED TO MATCH FIXTURES. VII. WIRE AND CABLE 600 VOLT: 4. SPECIAL MOUNTING BRACKETS, TENONS, SLIP FILTERS, CONCRETE BASES, POLES, ANCHOR M. UPON COMPLETION OF WORK, THE ENTIRE WIRING SYSTEM SHALL BE TESTED, AND SHALL BE A. IDENTIFICATION NAMEPLATES SHALL BE LAMINATED PLASTIC, SECURED TO EQUIPMENT WITH TWO BOLTS, JUNCTION BOXES, AND STANCHIONS FOR ALL EXTERIOR LIGHTING FIXTURES. SHOWN TO BE IN PROPER WORKING CONDITION IN ACCORDANCE WITH INTENT OF SPECIFICATIONS SCREWS. A. CONDUCTORS SHALL HAVE CURRENT CARRYING CAPACITIES AS PER NEC AND WITH 600 VOLT PROVIDE ALL WEATHERPROOFING FOR ALL LIGHTING FIXTURES TO BE INSTALLED IN AND DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE ALL SYSTEMS INSULATION, #12 AVERAGE MINIMUM FOR 20 AMP CIRCUITS AND #14 FOR 15 AMP CIRCUITS EXTERIOR LOCATIONS. READY FOR OPERATION AND TO HAVE AN ELECTRICIAN AVAILABLE TO OPERATE SAME IN B. EACH PANELBOARD AND SWITCHBOARD SHALL BE EQUIPPED WITH A PERMANENT PLASTIC EXCEPT FOR CONTROLS AND FIXTURE WIRE. CONDUCTORS SHALL BE COPPER. ACCORDANCE WITH AND UNDER THE SUPERVISION OF THE INSPECTION REPRESENTATIVE OF THE NAMEPLATE WITH 1/2" MINIMUM LETTERS, SECURELY FASTENED TO THE DEVICE. D. STRUCTURAL SUPPORT OF ALL FIXTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ENGINEER. THE CONTRACTOR SHALL BE AVAILABLE TO ASSIST IN REMOVAL OF PANEL FRONTS, B. #12 AND #10 SHALL BE SOLID, TYPE THW/THWN INSULATION. ETC., TO PERMIT INSPECTION AS REQUIRED. C. EACH INDIVIDUALLY MOUNTED CIRCUIT BREAKER, SWITCH, TRANSFER SWITCH, MOTOR STARTER, E. THE SYSTEM GROUNDING CONDUCTOR SHALL BE SECURED TO EACH FIXTURE BODY BY MEANS N. IN ACCORDANCE WITH DIVISION 1 AND THE CONDITIONS OF THE CONTRACT, THE CONTRACTOR LIGHTING CONTACTOR, TRANSFORMER AND/OR ANY OTHER CONTROL OR PROTECTIVE DEVICE C. #8 AND LARGER, AND ANY SIZE TO MOTORS SHALL BE STRANDED TYPE THW. OF A BONDING SCREW. SHALL PROVIDE AND KEEP UP TO DATE A COMPLETE RECORD SET OF CONSTRUCTION "AS-BUILTS INCLUDING EQUIPMENT DISCONNECT SWITCHES SHALL BE EQUIPPED WITH A PERMANENT PLASTIC NAMEPLATE WITH 1/2" MINIMUM LETTERS. D. SHALL BE MADE WITH T & B STA-KON WIRE JOINTS, PT SERIES, COMPLETE WITH INSULATING F. OWNER/DEVELOPER WILL HAVE RIGHT TO RELOCATE LIGHTING FIXTURES OR LIGHTING SWITCHES BLU" THE ORI PRINTS WHICH SHALL BE CORRECTED DAILY, AND SHALL SHOW EVERY CHANGE FROM THE ORIGINAL CONTRACT DRAWINGS, INCLUDING ADDENDA AND CHANGE ORDERS IN CAPS AND INSTALLED WITH WT161 TOOL OR WT2000 -TOOL., IDEAL SUPER -NUTS NOT WIRE ( WITHIN 72" OF LOCATION SHOWN ON FIRST WALK-THROUGH AT NO ADDITIONAL EXPENSE. ACCORDANCE WITH GENERAL REQUIREMENTS ANDHALLSPECIAL CONDITIONS. THIS SET D. PANELBOARDS SHALL HAVE TYPEWRITTEN DIRECTORIES. ALL CIRCUITS TO BE IDENTIFIED BY _ COORDINATE THE WALK-THROUGH PRIOR TO THE INSTALLATION OF THE WIRING. O SHALL BE KEPT ON THE JOB SITE, AND SHALL BE USED ONLY AS A RECORD SET. THIS DEVICES SERVED AND ROOM NUMBERS (I.E., LIGHTING ROOM 216 HANDWRITTEN DIRECTORIES WILL ) SURE CONNECTORS COMPLETE WITH NYLON SNAP-ON UNSULATORS AND INSTALLED WITHC24PRINTS SHALL NOT BE CONSTRUED AS AUTHORIZATION FOR THE CONTRACTORS TO MAKE CHANGES IN THE NOT BE ALLOWED. PRESSURE TOOL. LAYOUT WITHOUT DEFINITE INSTRUCTION IN EACH CASE. E. EACH JUNCTION BOX CABINET OR WIREWAY LARGER THAN 6" X 6" SHALL BE EQUIPPED WITH A E. ALL JOINTS AND SPLICES IN WIRE SHALL BE MADE WITH APPROVED SOLDERLESS CONNECTORS, 11. ELECTRICAL SCOPE: PLASTIC NAMEPLATE WITH 1/2" MINIMUM LETTERS INDICATING THE SYSTEM ENCLOSED. AND COVERED SO THAT INSULATION IS OWNER APPROVED EQUAL TO CONDUCTOR INSULATION. SPLICES SHALL NOT BE PERMITTED IN CONTROL, SECURITY, FIRE ALARM, TELEVISION OR A. FURNISHING AND INSTALLATION OF POWER SYSTEMS, AND AUXILIARY SYSTEMS AS SHOWN F. ALL SYSTEMS JUNCTION BOXES AND CONDUIT SHALL BE COLOR CODED INSIDE AND OUTSIDE OF COMMUNICATIONS SYSTEMS, OR WHERE OTHERWISE NOTED. SPLICING OF WIRE OR CABLES WILL OR HEREIN SPECIFIED. THE BOX PRIOR TO THE INSTALLATION OF CONDUCTORS PER THE FOLLOWING: NOT BE ALLOWED BELOW GRADE, INCLUDING IN BOXES BELOW GRADE. B. CONNECTION OF ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTION, MENTIONED IN THIS 1. CCN SYSTEM: GREEN F. BOTH CONDUCTORS AND CONDUITS SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. DIVISION OR SHOWN ON DRAWINGS, WHETHER FURNISHED BY DIVISION 16 OR UNDER 2. TELEPHONE DATA SYSTEM: BLUE OTHER DIVISIONS, OR FURNISHED BY OWNER. 3. FIRE ALARM SYSTEM: RED G. IN INSTALLING THE MAIN ELECTRICAL SERVICE, ADDITIONAL SLACK CONDUCTORS SHALL BE PROVIDED AND TERMINATED AS REQUIRED BY ELECTRIC UTILITY FOR CONNECTION TO THEIR C. FURNISHING AND INSTALLATION OF OUTLET BOXES, CONDUIT RACEWAYS, FOR A TELEPHONE AND G. ENTIRE BOX INSIDE AND OUT, INCLUDING COVER, SHALL BE PAINTED PRIOR TO INSTALLING EQUIPMENT. FIELD COORDINATE WITH UTILITY PRIOR TO INSTALLING CONDUCTORS. DATA RACEWAY DISTRIBUTION SYSTEM. (TELEPHONE AND DATA HARDWARE, AS WELL AS WIRING AND CONDUCTORS. SOFTWARE IS NOT INCLUDED.) H. IN INSTALLING PARALLEL CONDUCTORS IT IS MANDATORY THAT ALL CONDUCTORS MAKING UP THE N. WIRING DEVICES: FEEDER BE EXACTLY THE SAME LENGTH, THE SAME SIZE AND THE SAME TYPE OF CONDUCTOR D. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR CONTACTING THE OFFICES OF ALL LOCAL WITH THE SAME INSULATION. FURTHER, EACH GROUP OF CONDUCTORS MAKING UP A PHASE OR AND/OR STATE AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT IN ORDER TO SCHEDULE ALL A. SWITCHES AND RECEPTACLES IN LOBBIES, CORRIDORS OR COMMERCIAL SPACES, UNFINISHED AND NEUTRAL MUST BE BONDED AT BOTH 'ENDS IN AN APPROVED MANNER. REQUIRED INSPECTIONS AND OBTAIN ALL NECESSARY PERMITS, ETC. THE CONTRACTOR SHALL NOTIFY MECHANICAL SPACES SHALL BE 20 AMP COMMERCIAL GRADE 125 VAC. GRAY IN COLOR WITH THE ARCHITECT/ENGINEER OF ALL SCHEDULED INSPECTIONS AT LEAST TWO WEEKS IN ADVANCE OF STAINLESS STEEL COVERPLATES. I. CONDUCTOR SIZES INDICATED ON CIRCUIT HOMERUNS OR IN PANELBOARD SCHEDULES SHALL BE INSTALLED OVER THE ENTIRE LENGTH OF THE CIRCUIT UNLESS NOTED OTHERWISE ON THE THE SCHEDULED DATE. B. WEATHERPROOF RECEPTACLES SHALL BE GFCI TYPES WITH GASKETED STAINLESS STEEL KEY DRAWINGS. E. THE CONTRACTOR SHALL REPLACE ANY DEFECTIVE MATERIALS, EQUIPMENT, OR WORKMANSHIP LOCKABLE FLIP COVER TYPE COVERPLATES. SURGE SUPPRESSION TYPE OUTLETS IN MDFS AND IDES SHALL BE HUBBELL #83625 (BLUE) OR EQUAL. J. CONDUCTORS SHALL BE CONTINUOUS AND UNSPUCED WHERE INSTALLED IN CONDUIT. SPLICES WITHOUT COST TO THE OWNER WITHIN THE STIPULATED GUARANTEED PERIOD. SHALL OCCUR ONLY WITHIN WIRING TROUGHS, WIREWAYS, JUNCTION BOXES, OUTLET BOXES, OR F. IT SHALL BE THE RESPONSIBILITY OF THE DIVISION 16 CONTRACTOR TO HAVE ALL SYSTEMS C. RECEPTACLES PROVIDED FOR ATTACHMENT OF CORD AND PLUG EQUIPMENT SHALL BE HEAVY EQUIPMENT ENCLOSURES WHERE SUFFICIENT ADDITIONAL ROOM IS PROVIDED FOR ALL SPLICES. - FOR OPERATION AND TO HAVE AN ELECTRICIAN AVAILABLE FOR ALL INSPECTIONS. THE READY EL READY DUTY, SPECIFICATION GRADE, NON -INTERCHANGEABLE, FLUSH MOUNTED TYPES OF THE PROPER NEMA CONFIGURATION TO SERVE THE EQUIPMENT. NEMA CONFIGURATIONS SHALL BE VERIFIED PRIOR TO K. EACH BRANCH CIRCUIT AND FEEDER CONDUCTOR SHALL BE COLOR CODED. FOR CONDUCTOR CONTRACTOR SHALL PROVIDE PERSONNEL ASSIST IN REMOVAL OF PANEL FRONTS, ETC. TO PERMIT INSTALLATION OF CIRCUIT CONDUCTORS. CONTRACTOR TO PROVIDE ALL CONNECTION, WIRING, PIGTAILS SIZES THRU NO. 6 AWG, THE INSULATION SHALL BE OF THE COLOR AS INDICATED BELOW. COLOR INSPECTION AS REQUIRED. FOR DISHWASHERS, COOKING RANGES, OVENS AND GARBAGE DISPOSALS. CODE SHALL BE STRICTLY ADHERED TO. FOR CONDUCTOR SIZES NO. 4 AWG AND LARGER, COLOR CODED PHASE TAPE MAY BE APPLIED COMPLETELY AROUND THE CONDUCTOR INSULATION G. SUBMIT TO THE ARCHITECT/ENGINEER PROMPTLY AFTER AWARD OF CONTRACT AND PRIOR TO D. ALL DEVICES SHALL HAVE PROPER PLATES, CARPET FLANGES, TRIMS, RINGS, ESCUTCHEONS, WITHIN 8" OF EACH END OF THE CONDUCTOR AND IN EACH PULL OR JUNCTION BOX OR WHENEVER PURCHASING, SIX COPIES OF MANUFACTURER'S SHOP DRAWINGS IN ACCORDANCE WITH ETC., AS MANUFACTURED BY SAME MANUFACTURER AS DEVICES. ANY TELEPHONE OR OTHER OUTLET. CONDUCTORS ARE PHYSICALLY EXPOSED TO VIEW. GROUNDING CONDUCTORS AND GROUNDED DIVISION 1, SECTION 01300 - SUBMITTALS FOR THE FOLLOWING ITEMS. ALL SHOP DRAWINGS OF A WHICH IS NOT EQUIPPED WITH A PLATE FURNISHED BY OTHERS SHALL HAVE ONE PROVIDED BY THIS CONDUCTORS SHALL HAVE INSULATION COLOR AS INDICATED FOR SIZES THROUGH #6 AWG. SPECIFIC ITEM OR SYSTEM SHALL BE MADE IN ONE SUBMITTAL AND WITHIN TEN DAYS AFTER AWARD CONTRACTOR. DEVICE PLATES SHALL BE COLOR AND TYPE AS SHOWN BELOW. 120/208 V, 3PHASE,4W OF CONTRACT. 1. FINISHED SPACES DECORA LINE: PHASE A, COLOR: BLACK 1. PANELBOARDS 4. DISCONNECT SWITCHES a. IVORY DEVICES PHASE B, COLOR: RED 2. SUPPORTS 5. CONDUIT b. IVORY NYLON PLATES PHASE C, COLOR: BLUE 3. WIRING DEVICES 6. WIRE 2. UNFINISHED OR INDUSTRIAL OR COMMERCIAL TYPE SPACES: NEUTRAL, COLOR: WHITE H. COMPLETED WIRING SYSTEMS SHALL BE FREE FROM SHORT CIRCUITS AND AFTER COMPLETION, a. GRAY DEVICES b. STAINLESS STEEL OR STAMPED GALVANIZED STEEL ON SURFACE MOUNTED BOXES GROUND, COLOR: GREEN PERFORM TESTS FOR INSULATION RESISTANCE IN ACCORDANCE WITH THE REQUIREMENTS OF THE c. STAINLESS STEEL PLATES ON FLUSH MOUNTED BOXES VIII. GROUNDING: NATIONAL ELECTRICAL CODE. ALL WIRING SYSTEMS SHALL BE COMPLETELY AND TOTALLY "SAFED" DURING CONSTRUCTION. ONLY QUALIFIED PERSONNEL SHALL HANDLE ELECTRICAL SYSTEMS. A. THIS SECTION DEALS WITH THE GROUNDING OF SERVICE EQUIPMENT, TRANSFORMERS, NON - I. BEFORE ROUGH -IN OF CIRCUITRY OR CONNECTING TO EQUIPMENT, FURNISHED UNDER THIS CURRENT CARRYING CONDUCTIVE SURFACES OF EQUIPMENT, METAL BUILDING, STRUCTURES AND OTHER EQUIPMENT. DIVISION, ANY OTHER DIVISION, OR BY THE OWNER, THE CONTRACTOR SHALL VERIFY THE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF THE EQUIPMENT BEING FURNISHED AND FOR THAT SPECIFIED AND SHOWN ON THE DRAWINGS AND PROVIDE FOR PROPER ROUGH -IN AND CONNECTION. , REN CE E'�•'�©c�, *� • 0. E0 BlalCaw' th F77 c 0 U U) Q) 0 a� ro 0 U � e � a oF-- c o c LLJmoo^ V ri QVPI.J C Qnm�Z ° m� Nelson Blankenship, AIA AUC°a10- U�Q v aHM� 0 Ct U � o �C O O Ct DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1716 DRAWING NUMBER E-501 DATE 02-23-18