Loading...
HomeMy WebLinkAbout1612-1616 Airport Blvd 99-2475 Interior remodelCITY OF SANFORD BUILDING DIVISION COMMERCIAL REVIEW COMMENTS INTERIOR ALTERATIONS PROJECT:-.nlleP-oe,, ,zilql-opI -9 DATE: Juwt a, Ig49 ADDRESS: /61411614 A I&S-1t1./4iP P* SANFORD, FL CONTRACTOR: A4W ,0. ,(,e eft, LICH C Z?e-,,03,3G % ADDRESS: fS' ,,l S;i/,o PHONE: $3p-/`i4- X1. Means of egress and occupant load shall comply to Section 1003 1997. S.B.C. 2 Means of egress and illumination shall comply to Section 1016.1, 1016.2 and 1016.3 signs), 1997 S.B.C. 3. All corridors shall be a minimum of 44", Table 1004, 1997, S.B.C. x 4. All restrooms shall comply to 1997, H.C.F.S, 553, Part S. 5. Interior finishes shall comply to Sec. 704, Table 803.3,1997, S.B.C. 6. All electrical wiring service & fixtures shall comply to 1996, N.E.0 and Notice L amendments. e-• 7. All plumbing shall comply to 1994,S.P.C. 8. All mechanical equipment & duct systems shall comply to 1997, S.M.C. & 1997, Florida Energy Code. X 9. Firewalls or tenant separations shall comply to Table 413.3 & Table 704.1 & 704.1.4, penetrations shall be sleeved and fire caulked. tr' 10. Stairs shall comply to Section 1006,1007,1007.1.2,1007.3,1007.4,1007.5,1007.5.3,1007.6,1007.7, 1007. 8,1008.6, & 1015, 1997, S.B.C. 11. Shall comply to 1994, N.F.P.A. -1. 12. Shall comply to Life Safety Code 101, 1994. Review By:0 REQUIRED INSPECTIONS DURING AND UPON COMPLETION OF CONSTRUCTION: 1. Footer 2. Underground electrical, mechanical and plumbing 3. Slab 4. Lintel and/or tie beam 5. Rough electrical 6. Rough mechanical 7. Plumbing rough 8. Tub Set 9. Framing 10. Insulation, walls and/or ceilings 11: Electrical final, mechanical final and plumbing final 12. Building final h Date: Signature: t• t CITY OF SANFORD FIRE DEPARTMENT 1303 South French Avenue Sanford, Florida 32771 407) 302-1091 (407) 302-1097 FAX Plans Review Sheet Date: June 1,1999 Business Address: Occ. Chap. 26 Business Name: Bureau of Census Ph. Contracwr.. Design Enterprises, Inc. Ph. 830-1414 Reviewed [ ] Reviewed with comment 7 ] Rejected Reviewed by: Bart Wright, Fire Protection Inspecto Comment: 1.1 Application — Renovation to existing business location 1.2 Mixed — N/A 1.3 Special Definitions — N/N 1.5 Classification of Hazard of Contents - Ordinary 1.6 Minimum Construction — N/R; provided type IV up; 1.7 Occupant Load — 1 / 100 sq. ft. (for egress capacity) 2.2 Means of Egress Components — O.K. 2.3 Capacity of Egress — O.K. 2.4 Number of Exits — O.K. 2.5 Arrangement of Egress — O.K. 2.6 Travel Distance — O.K. 2.7 Discharge from Exits — O.K. 2.8 Illumination of Means of Egress - O.K.; will field verify 2.9 Emergency Lighting - O.K.; will field verify 2.10 Marling of Means of Egress - O.K.; will field verify 1 2.11 Special Features — O.K. 3.1 Protection of Vertical Openings — N/A 3.3 Interior Finish — Class "C" 3.4 Detection, alarm and Communications Systems — N/R 3.5 Extinguishing Requirements — 2 x 2A 1 OBC portable fire extinguishers 3.6 Corridors — N/N 4 Special Provisions — N/N 5 Budding Services — No comment 5.1 Utilities 5.2 HVAC 5.3 Elevators, Escalators, Conveyors (4A-47) 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes Sanford City Code - Chapter 9 Fire Sprinklers: Not Required Monitoring: N/A Other: NFPA 1 3-5.1 Fire Lanes — N/A to tenant build out 3-6.1 Key Box - Required, will field locate and verify 3-7.1 Bldg. Address Number Posted and Legible - Required, will field locate and verify