HomeMy WebLinkAboutLady Foot Locker (2)OE JAGER CONSTRUCTION INC.
75 60TH STREET, S.W. • P.O. BOX 815 • WYOMING, MICHIGAN 49518
616) 530-0060 • FAX (616) 530-9888 -
June 22, 1995
SUBJECT: Lady Foot Locker - #7246
Seminole Town Center
Sanford, FL
Please accept this letter as my authorization for Rex Martin,
my supervisor, to act in my behalf and in my absence as signatory
for the Building Permit for the Lady Foot Locker, Seminole Town
Center, Sanford, FL.
Enclosed please find a copy of my State License for your use..
o ert Menkve , Vice res t
DeJager Construction, Inc.
STATE: Michigan
COUNTY Kent
BEFORE ME, the undersigned, a Notary Public in and for the said
County and State, on this day personally appeared ROBERT MENKVELD,
known to me to be the person whose name is subscribed to the
foregoing instrument, and acknowledged to me that the same as the
act of such Corporation for the purposes and consideration therein
expressed, and in the capacity therein stated.
GIVEN UNDER MY HAND AND SEAL, THIS 22nd day of June, 1995. 1
Mary inter, tary blic
Kent County, Michiga
My commissioh. expires: 12/21/98
GENERAL CONSTRUCTION • STORE AND OFFICE INTERIORS * COMMERCIAL REMODELING
f SYSTEM SIZING SUMMARY
System Name : Lady Foot Locker 06-05-95
Location : Orlando, Florida Block Load v2.12
Prepared By : A&E DESIGNERS,INC. Page 1 of 2
TABLE 1. SIZING DATA -- COOLING
L
coil load = 37,455 BTU/hr Load occurs @ Jan 2300
Sensible coil load 29,202 BTU/hr Outdoor Db/Wb = 66.9/ 63.2 F
Total zone sensible= 22,863 BTU/hr Coil Conditions:
Supply temperature = 55.0 F Entering Db/Wb = 80.2/ 65.9 F
Supply air (actual)= 1,063 CFM Leaving Db/Wb = 54.7/ 54.0 F
Supply air (std) = 11058 CFM Apparatus dewpoint= 53.3 F
Ventilation air = 0 CFM Bypass factor = 0.050
Direct exhaust air = 0 CFM Resulting zone RH = 56.0 %
Reheat required = 0 BTU/hr
Floor area (sgft) 1,965 Total coil load = 3.12 Ton
Overall U-value 0.000 Sensible coil load = 2.43 Ton
Vent air CFM/sgft' 0.00 SQFT/Ton 629.56
Vent- airCFM/person 0.00 Cooling BTU/hr/sgft = 19.06
Cooling CFM/sqft = 0.54 Q
TABLE 2. SIZING DATA -- HEATING
Heating coil load = 882 BTU/hr Heating BTU/hr/sgft 0.45
Ventilation load 0 BTU/hr Heating CFM/sqft 0.54
Total zone load = 882 BTU/hr Floor area (sgft) 1,965
Ventilation airflow= 0 CFM Overall U-value 0.000
Supply airflow = 11063 CFM Vent air CFM/sqft 0.00
Vent air CFM/person 0.00
TABLE 3. INPUT DATA -- WEATHER
city = Orlando Summer dry-bulb = 94.0 F
State = Florida Coincident wet -bulb= 76.0 F
Data Source = ASHRAE 1% Daily Range = 17.0 F
Latitude = 28.4 deg. Winter dry-bulb = 35.0 F
Elevation = 106.0 ft Atmos.• Clear. Num. = 0.90
TABLE 4. INPUT DATA -- HVAC SYSTEM
System Type Clg & Warm Air Htg THERMOSTAT SETPOINTS
System Start 600 Cooling (Occ) 75.0 F
Duration 24 hrs Cooling (Unocc) 85.0 F
Heating 55.0 F
SIZING SPECIFICATIONS FACTORS
Supply 55.0 F Coil Bypass 0.050
Ventilation 0.00 CFM/person Safety (Sens) 0 8
Exhaust _ : 0 CFM Safety (Latent) 0 %
Heating Safety 0 %
FAN RETURN AIR PLENUM Y
Configuration : Draw-Thru Roof Load 70
Static Pressure : 0.50 in. 8 Lighting Load 30
8 Wall Load 0
SYSTEM SIZING SUMMARY \
System Name : Lady Foot Locker 06-05-95
Location : Orlando, Florida Block Load v2.12
Prepared By : A&E DESIGNERS, INC. Page 2 of 2
TABLE 5. TOP TEN COOLING COIL LOADS
Sensible Total Sensible Total
Time Ton Ton Time Ton Ton
2.431) Jan/2300 3.12 6 June/2300 2.43 3.12
2) Feb/2300 2.43 3.12 7) July/2300 2.43 3.12
3) Mar/2300 2.43 3.12 8) Aug/2300 2.43 3.12
4) Apr/2300 2.43 3.12 9) Sept/2300 2.43 3.12
5) May/2300 2.43 3.12 10) Oct/2300 2.43 3.12
TABLE 6. ZONE SIZING DATA
r- ----------------- -- -- ---- -----------------
Maximum Design Maximum Design
Cooling Airflow Design Heating Flow
Sensible Rate Time Load Rate
Zone Name (BTU/hr) CFM) BTU/hr) CFM)
Lady Foot locker 22,863 1,063 @ Jan 2300 882
0 u-,weA.ie.%L. MA1- c- rw4 of l.oSc"'' CrFVA
5 ?
kG4: I oy Lo"faR uptdl. I tx 16+-W-ac [ Lo *W 7 ho Co ka, $ 7 j
Awe V.P& e.U_ %I. Woo a jV1bF ,