Loading...
HomeMy WebLinkAbout3536 Country Club Rd 18-4173 re roofua� -X8'3- 7?y3 OCT. Q $ 2018 PERMIT APPLICATION Ob Application No: IR — Y/71 Documented Construction Value: $97 fiMM nn Job Address: MIA rnnfy r., ,, RA , a G, Maintenance building Historic District: Yes ❑ No0 Parcel ID: oa2o3o-3m.00 Residential ❑ Commercial x❑ Type of Work: New ❑ Addition ❑ Alteration Repair ❑ Demo❑ Change of Use ❑ Move ❑ Description of Work: Re -roof 3.500 sq. ft.. Replace with 26 gauge Galvalume 5V crimp roof panels attached with neoprene head screws. Plan Review Contact Person: Jasper Bowling Title: President Phone: 4o7-563-7943 Fax: 407-650.3183 Email:_ AI itafidaolrnm Property Owner Information Name Sanford, City of Phone: 407-6885000 x5409 Street: 3536 Country Club Rd. City, State Zip: Sanford, FL 32773 Resident of property?: no Contractor Information Name Jasper Bowling Phone: 407-583-7943 Street: P.O. Box 1203 City, State Zip: Geneva, FL 32732 Name: Street: City, St, Zip: Bonding Company: Address: Fax: 407-650-3183 State License No.: CCC1326196 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: & Edition (2017) Florida Building Code NOTICE :In addition to therequirements of this permit, there may be additional restrictionsapplicable to this property that maybe found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the pjroperty of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will he figured based on the current ICC Valuation Table in effect at the(ime the permit is issued, in accordance with local ordinance. Shouldcalculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the for information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. ��8 Signature of(0 cr/Agent Date 340 Notary Public State of Flodd Rebecca Butyls My Commission FF 974489 "corn ExQM07/2312020 Produced ID Type of ID Me or r $ arm • orcon rac[orlA at Date i .-Jasper Rnw ing Print Contactor/Agent's Name Signature of Notary -State of Florida MEQm8mrN Dnte 10/4/2018 rtMr% �:....• , WCOta43MIFF EKP1ES:1A211,2= "c0ynFFw6wimWtWyWu Contractor/Agent is x Personally Known to Me or Produced ID TypeoflD BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Gas ❑ Roof ❑ Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps plumbing - # of Fixtures Fire Sprinkler Permit: Yes ❑No ❑ # of Heads 1 Fire Alarm Permit: Yes ❑ No ❑ APPROVALS: ZONING: UTIL1TI1 S: WASTE WATER: ENGINEERING: F*E: BUILDING: COMMENTS: CITY OF � T Building & Fire Prevention Division �7r Alr DLW COMMERCIAL ROOF PERMIT GUIDELINES Fest oUAstTM.i N; All permit application packages must be complete prior to acceptance. You must check each box to the left/or indicate n/a on this submittal. A complete application package shall include the following: L9/ Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. Copy of a contract, signed by the contractor and the property owner, indicating the documented / construction value of the project. C9' Copy of applicable contractor's license issued by the State of Florida (if the contractor is the applicant). ❑N* A site specific notarized power of attorney shall be required from the licensed contractor if / he/she appoints an employee of his/her company to sign the permit application as the contractor. LY Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of Florida (must be submitted with each application if contractor is the applicant). ❑,Vft Owner Builder Statement / Affidavit (if the owner is the applicant). (Must be signed in person at the Building Department) t3� Two (2) copies of Florida Product Approval and Manufacturer installation Instructions for the roof covering product and the underlayment. ** Please Note — Commercial Roof Permits require a Dry In and Final Roof Inspection. ** These guidelines were compiled to assist the applicant in preparing a roof permit application and may not be complete. The applicant is required to meet all City of Sunjbrd, state, and federal code requirements. Effective: August 1, 2017 y5~�F.O RLS FC CIT OF �., DIVISION PERMIT APPLICATION Application No: Documented Construction Value: $17 AM M Job Address: xu r Ch h Rdq,fnrrf Fr Maintenance building Historic District: Yes ❑ No x❑ Parcel ID: 04-20-3o ioo-oo3o-DoW Residential ❑ Commercial x❑ Type of Work New ❑ Addition ❑ Alterationx❑ Repair ❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work Re -roof 3,500 sq. ft.. Replace with 26 gauge Galvalume 5V crimp roof panels attached with neoprene head screws. Plan Review Contact Person: Jasper Bowlino Title: president Phone: 407-5a3a943 Fax: 4o7-5w-3ia3 Email: atrraaR Qatit corn Property Owner Information Name Sanford, City of Phone: 407-688-5000 x5409 Street: 3536 Country Club Rd. Resident of property?: no City, State Zip: Sanford, FL 32773 Name Jasper Bowling Street: P.O. Box 1203 City, State Zip: Geneva, FL 32732 Name: Street: City, St, Zip: Bonding Company: Address: Contractor Information Phone: 407-583-7943 Fax: 407-650-3183 State License No.: CCC1326196 Architect/Engineer Information Phone: Fax: E-mail: _ Mortgage Lender. Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain apermit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 1053 Shall be inscribed with the date of application and the code in effect as of that date: & Edition (2017) Florida Building Code NOTICE luaddition to the requirements of this permit, diene maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there maybe additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated constructionvalue of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction wine, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agents Name Date Signature ofNotarySlate of Florida Date Owner/Agent is _ Personally Known to Me or Produced ID Type of ID arw ofcontrnctm/A 'ra DahD18 —Jasper Rawling Print Conlractorldgent's Name owQrI.O 'q L Signature of Notary -State of Florida Date 1 df4/2018 r°vsr"kk ANF?NON &MOH % p E(PIRE& %Jit,M rarno° Batllaft8*dWw1W W1 Contractor/Agent is x_ Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Gas ❑ Roof ❑ Construction Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: # of Stories New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes []No ❑ # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: COMMENTS: Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: BUILDING: !'d– g. Portability Adj �. - Save Our Homes Adj 50 50 + avr- JII Amendment 1 Adj $52,766 $87,328 li r Assessed Value $762409 693,099-- PBG Adj $0 $ $6 so^j yyy� I, 0.00 Tax Amount without SOH: } $ 2017 rax Bill Amours; ;O.00 Tax Estimator Save Our Homes Savings: $0.00 -� 6 { Jr✓n :,(�S; r� -"" i ' Does NOT INCLUDE Non Ad Valorem Assessments - -- Legal Description AMRI Proper Record Card Parcel: 04-20-30.300-0030-0000 - ssusaicrnyxrxaa.0 I PropertyAddress: 3536 COUNTRY CLUB RD SANFORD, FL 32771 I Parcel Information Value Summary Parcel 042030-300-0030-0000 2018 Working 12017 Certified -- — - - _-- --- - Owner(s) � SANFORD, CITY OF -... _ _. _- _ : _�_._ values _.....___.._ Values _ -- ------ - -- --- ---- ! - Properly Address) 3536 COUNTRY CLUB RD SANFORD, FL 32771 Valuation Method Cos VMarket CosVMarket Number of Bu0tlings 9 9 Mailing C/O MAYFAIR COUNTRY CLUB 13536 COUNTRY CLUB RD SANFORD. FL32771 Depreciated Bldg Value $431,640 5396,892 Subdivision Na— me Depredated EXFT Value $17,332 517,332 Tax DistrictSISANFORD - Land Value (Market) $366,203 5366203 DOR Use Code - j 38 -GOLF COURSE Land value Ag Exemptions i 80-CITY(2013) "I Jusb'Ictarkel'falue $815,175 5780,427 j Portability Adj �. - Save Our Homes Adj 50 50 + avr- JII Amendment 1 Adj $52,766 $87,328 li r Assessed Value $762409 693,099-- PBG Adj $0 $ $6 so^j yyy� I, 0.00 Tax Amount without SOH: } $ 2017 rax Bill Amours; ;O.00 Tax Estimator Save Our Homes Savings: $0.00 -� 6 { Jr✓n :,(�S; r� -"" i ' Does NOT INCLUDE Non Ad Valorem Assessments - -- Legal Description DATE: 09/11/18 PURCHASING OFFICE 407.688.6030 ACCOUNTS PAYABLE: 407.688.5020 FACSIMILE: 407.689.5021 VENDOR NO.: 12394 TO: ALL-TITE ROOFING INC PO BOX 1203 GENEVA, FL 32732 PURCHASE ORDER PO NUMBER 036098 CITY OF SANFORD P.O. BOX 1788 (300 NORTH PARK AVENUE) SUBMIT INVOICES TO: ACCOUNTS PAYABLE SANFORD, FLORIDA 32772 FINANCE DEPT. FLORIDA TAX EXEMPT NO.: 85 801 2621 6 61 C-8 P.O. BOX 1789 SANFORD,FL32772 SHIP TO: CITY OF SANFORD 300 N. PARK AVENUE PARKS DEPARTMENT SANFORD, FL 32771 DELIVER BY TERMS F.O.B. DESTINATION BID OR QUOTATION NO. REQUISITION NO. 09/30/18 NET UNLESS OTHERWISE INDICATED 66716 ACCOUNT NO.: 455-5502-575.46-00 PROJECT NO.: NO DEVIATION FROM THIS PURCHASE ORDER WILL BE ALLOWED UNLESS AUTHORIZED BY THE PURCHASING MANAGER - CIN OF SANFORD ITEM NO. DESCRIPTION QUANTITY UNIT OF ISSUE UNIT COST EXTENDED COST 1 REMOVE S REPLACE METAL ROOF 17500.00 NA 1.00 17500.00 PRICE TO INCLUDE• REMOVE 3,500 SQFT OF METAL SLOPE 7 6/12 _ B v INSPECT 900D PURLINS FOR ROTTEN WOOD. WOOD REPLACEMENT @ $55 PER MAN HR PLUS MATERIAL, NOT TO EXCEED $1,500 INSTALL NEW 26 GUAGE GALVALUME 5 V CRIMP ROOF PANE LS ATTACHED WITH NEOPRENE HEAD SCREWS NEW EAVE METAL 26 GAUGE GALVALUME CLEAN UP AND REMOVAL OF ALL ROOFING DEBRIS SUB TOTAL 17500.00 TOT 17500.00 APPROVED Y: � 1. log APPROVED BY: PURGHA$I�G A ENT �1�T� GITY M AGER All packages and Invoices applicable to Is P 0. must bear this P.O. Number. The Vendor shell comply with all specified and referenced herein before and after. Any a mpts to insert language to change these terms and conditions are hereby rejected and will be resolved in favor of the City of Sanford. Standard terms and conditions hereby incorporated into this purchase order may be found at http://,nrww.sanfordfl.gov/index.aspx?page=879 Terms and conditions applicable to P.O.'s and at Additional Terms and conditions http://www.sanfordfl.gov/indbx.espx?page=883 OFFICE City of Sanford Building and Fire Prevention Product Approval Specification Form Permit# 1-f- L// 73 Project Location Address 3536 Country Club Rd. Maintenance Bldg. Sanford, FL As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Florida Approval # Exterior Doors Description include decimal) 1. Swinging Sliding Sectional Roll Up Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions — Wind Breaker Dual Action Other June 2014 1 OCT 0 8 2018 Category / Subcategory 3. Pane! Walls Siding Soffits Manufacturer Product Description Florida Approval # (including decimal Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles 5V crimp Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and- ndShin les Shingles Tri-County Metals FL4595-R4 Roofing tiles Roofing Insulation Waterproofing Built up roofing Sy stem Modified Bitumen Single Ply Roof Systems Roofina slate Cements/ Adhesives / Coatis Liquid Applied RoofingS stems Roof Tile adhesive Spray Applied Polyurethane Roofin E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory 6. Shutters Manufacturer Product Description Florida Approval # include decimal) Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skyli hts Other 7. Structural Components Wood Connectors I Anchors Truss Plates Engineered Lumber Railin Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck 1 Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Jasper Bowling (Please Print) June 2014 bd re 0� -� P ��DPYt1E SCIS Home Log In User Reglshatlon Hot Topicssubmit Surcharge stabs itFacbs Product Approval USER: Public User LrVdn�lnmyal Menu > arodhM dr Adp' r 5 rth I Application List Search Criteria aSPR+tirkG':ABdOr cgn, od9Ap(4 a,94fi`a., Code Version 2017 FL# Application Type ALL Product Manufacturer Category Roofing Subcategory Application Status ALL Compliance Method Quality Assurance Entity ALL Quality Assurance Entity Contract Expired Product Model, Number or Name ALL Product Description Approved for use in HVHZ ALL Approved for use outside HVHZ Impact Resistant ALL Design Pressure Other ALL FLIi TYRa ManufactLIM FL4595_ Revision Trl County Metals R4 FL#: FL4595.2 Isco Model: 5V Crimp Description: Min. 26 Ga. 5V Crimp Rn ff Panel over 1x4 Wood Purlins over 15/32" Plywood Category: Roofing Subcategory: Metal Roofing 'Approvetl by DBPR. AOpmvels Oy pBVR snali be mulewea anE retroed by tfte 1VC and/or me Commission it necessary. -- Corona Us:: Z¢QJ 01pir5bone R" tl, 1'allabass ➢ 99 phone, 050-4a7-1824 Refine Search 4595.2 Tri County Metals ALL ALL ALL ALL ALL ALL Validated Bs _ Status Brian 1aks, Approved P. E. (281)468- 0699 The State of Florida is an Ar,2EE0 employer Qay_agh 2007-2013 Sta t Florida.:: Pdvecv Statement:: Accessf6bty Smtement :: gefund Stat Under Ffmda law, email addresses are publie records. If you dp not want your e-mail address reldased in MVOnse to a public -records request, ad not send ekcrmnic mail to tits entity. Instead, contact Ne ornre 0' phone or by traditional mail. If you have any quer ions, Waase conal¢ 850.48J.1395. -Pursuant to SeM. 455.275(1), Florida Statutes, emotive call 1, 2012, fisensees Iisnsed under Chapter 455, F.S. must prgvide the Department whin an email atldres If they have ane. The emmis provided may be toed for oMtlal communication with the llcensee. However email addresses are pubbc recant. If you do not wish to supply a personal address, please mo, ide the DeparOnent with an email address Wilton an be made avallabie to the public To determine It you are a lbe sse under Chapter 455, F -S., please diol[ hsra . Product Approval Accepts: MW®RR ® Credit Card Safe t Bas Home Leg in l er ReglAmbon Ii. not Top16 Submit 5urehar9e Stats & Facts Pe41to,US,S contact us ' acts Site MSp L1n16 F Search ., db" 5 + Product Approval useR: W Glc urer Pmduet,lnnmval Men > ProdBCt er Appr a 5 N > Wlkaaon ll4 > Application De .il Fl -S FL4595-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer hl County Metals Address/Phone/Emall 301 SE 16th Street Trenton, FL 32693 (352)463-8400 chrisw@tricountymetals.com Authorized Signature Chris Weatherilt chrlsw@tricountymetals.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Flonda Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Terrence E. Wolfe Evaluation Report Florida License PE -44923 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 06/02/2024 Validated By Brian Jaks, P.E. Validation Checklist - Hardcopy Received Certificate or Independence X4595 R4 COI Letter of Certification securedodd Referenced Standard and Year (of Standard) Standard year FM 4471 1992 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page - 49 PFL n 4595.1 Model, Number or Name 5V Crimp Method 1 Option D 08/15/2017 08/172017 08/23/2017 10/10/2017 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design pressure: +N/A/-IOI.OPSF Other: -78.5 psf @ 16" o.c. Fastener Spacing. -101.0 psf @ L6" o.c. Fastener Spacing. Install per manufacturer's details. Not for use In HVHZ Zones. 4595.2 00 Pagel/200 Description I - J Min, 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood Installation instructions FI -4595 R4 11 26 Ga. 5V Crlmn P I plywood se�pAf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL4595 R4 -,AL -26 -GA -5V Crimp Pane over P ywood secured.odf Created by Independent Third Party: Yes bV Lnmp I Min. 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.OPSF Other: -78,5 psf @ 16' ex. Fastener Spacing. -101.0 psf @ 16" O.C. Fastener Spacing, Install per manufacturer's details. Not for use in HVHZ Zones, Installation Instructions FL4595 R4 It 26 Ga. SV-CrimpPanel over 1 4 NON HV14Z seeured.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL4595 R4 AE 26 Ga 5V Crimla panel Qv9r Ix4 NON HVHZ secured.odf Created by I ndependent Third Party: Yes Aluminum Mechanical -Seam Lok .032" Aluminum Mechanical Lock 16" Wide Roof Panel over Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/ -93.5 psf Other: -78.5 psf fa 18" O.C. dip spacing. -93,5 psf 6" O.C. Clip spacing. Install per manufacturer's details. For use in HVHZ Zones. Installation Instructions F1,4595 R4 {I Aluminum ML 1.5 over PlyiNgAct HVHZ SeSMLftd,pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL4595 R4 AE Aluminum ML 1.5 ov r Plywood HVHZ secured.bdf Created by Independent Third Party: Yes 4595.4 I Aluminum Mechanical -Seam Lok 2" Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5psf Other: -71.0 psf @ 24" o.c, dip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones, 4595.5 TCM Lok Limits of use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-112.Spsf Other; -75.0 psf at 4 1/2" o.c. fastener spacing. -112.5 psf at 4 1/2" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. 4595.6 Mechanical -Seam Lok 1-'/i' Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A .032" Aluminum, 2" Mechanical Lode, 19" Wide Roof Panel over j 22 Ga. Steel Deck Installation Instructions FL4595 R4 It Ai MI k 2.9 PY&E aUiel Deck HVHZ 5egured.m Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL4595 R4 AE AL MLok 2.0 over Steel Deck HVHZ '. sec re�r,pdf i Created by Independent Third Party: Yes 0.032" Aluminum TCM Lok Roof Panel over 7/16" OSB or 15/32" Plywood Installation Instructions FL4595 R4 It AlLminum TCMa ov PIv3g d -secured pdrr Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL4595 R4 AE Aluminum TCM LOK Over Plywwod-secured.pdf Created by Independent Third Party: Yes 1-y2" Mechanical Lock, 24 Ga., 16" Wide Roof Panel over Plywood Installation Instructions FL4595 R4 It Mechanical -Seam Loki over Plywood HVH- Secyred.odf Verified By: Terrence E. Wolfe, P.E. 44923 Product Evaluation Report TRI COUNTY METALS Min. 26 Go. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood FL# 4595.2 114 Florida Product Approval # 4595.2 R4 Florida Building Code 2017 Per Rule 6IG20-3 Method: 1—D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61620-3.005(1)(d) NON HVHZ Product Manufacturer: Tri County Metals 301 SE 16`h Street Trenton, Florida 32693 Engineer Evaluator: Terrence E. Wolfe, P.E. 444923 Florida Evaluation ANE ID: 1920 Validator: Brian Jaks P.E. 470159 Contents: Evaluation Report Pages 1-4 tt%s N I N4f,t, E. N..44 91j;' STATE OF Z or, I1D vu �re�e pone fir O Nfrill," W41ISt 14,'1017 Force Engirt : rinv ,`'sc Testing Inc. 19550 tiai!,N, mi Drire Hnmblr.i.A i'i3,i Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1504.7. Product Description: 5V Crimp Roof Panel, Min. 26 Ga. Steel, 24" coverage, through fastened roof panel over 1x4 wood purlins over one layer of asphalt shingles (optional) over min. 15/32" APA Plywood decking. Non -Structural Application. Panel Material/Standards: Material: Min. 26 Ga. Steel, conforming to Florida Building Code 2017 Section 1507.4.3. Paint finish optional. Yield Strength: Min. 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" min. Width: 24" maximum coverage Rib Height: 3/8" tall ribs Panel Fastener: ii9-15 x 1-1/2" Woodgrip with sealing washing or approved equal Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4. Substrate Description: Min. 1x4 No. 2 SYP wood purlins over maximum one layer of asphalt shingies/felt paper (optional) over min. 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. The 1x4 wood purlins shall be fastened to the plywood with (1) 8d x 2 3/8" Ring Shank Nail at 4" O.C. or to the wood rafters with (2) #9 x 3" Deck Screws at 24" O.C. Maximum. Design of 1x4 wood purlins, plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed In accordance w/ Florida Building Code 2017. Allowable Design Uplift Pressures: Table"A" Maximum Total uplift Design Pressure: 785 psf 101.0 psF Fastener Pattern: 12"-12" 30"-2%"-30" Fastener Spacing: 16" O.C. 16' O.C. FLft 4595.2 R4 *Design Pressure includes a Safety Factor = 2A ,0711Ylti Hell♦'♦ � E AGE' P_ �:' ♦� CE Ara J• '. STA7E 4E '< sr..>ws moi, F At op -1 1) NAL AurUSt 14.2017 1 4 , ' u E Force Erle neer;n,g Tcstino 19daU Nsmllc Hund D;icc H,nv Mr I'1 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.3.2, 1504.7, Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance standards: The product described herein has demonstrated compliance with: • UL580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-2012 -Uplift Test for Roof Covering Systems • FM 4471 -92 -Foot Traffic Resistance Test Reference Data: I. UL 580-06 / 1897-04 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 136-01.72T-12 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization #TST-5328) Report No. 136-0172T-12 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: The UL 1897-04 test standard is equivalent to the UL 1897-2012 test standard. The FM 4471-10, Foot Traffic Resistance test standard is equivalent to the FM 4471-92, Foot Traffic Resistance test standard Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61620-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details. 'ACE E 41 A�" *� ( • *_ STATE OF FL# 4;95.2 R4 August 14, 2017 Forcc I?nggiJnceting� &- Tcstilla Inc. 1�1jn N:unhlrn oad liri,.. Underlayment: Per Florida Building Code 2017, Section 1507.1.1 and manufacturer's installation guidelines. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. FL# 4595.2 K4 NCE. K E A's �l��i� P •gni No. 449 STATE OF •a 41 %0F FLoRi1) m.arrx. ��, J`S, • � A, ,� Au;ust 14, 2017 M --.TN. 26 GA.. 5V CRIMP PALET~, OVER 1X4 'FOOD PURLINS TYPE 1 FASTENER PATTERN AT T6" ox 12" � 12.' 1) 119 x 1 1/2 WDODGRIP w/ WASHER AT 12'-12' FASTENER PATERN AT 16' O.C. TYPE 2 FASTENER PATTERN AT )6" O.C. lo" 2 1/2" 10" 1) #9 x 1 1/2 WOODGRIP w/ WASHER AT 10'-Z 1/2'-10' FASTENER PATERN AT 16' QC. i; of Paft CAA. C"o Go pp w Qpe %t '14 o * : �u Z4 a ops a ., � �,� � � � • , e ; . � Vv�p tri1' L'�s��' p 4• Qa 0 RA.o.o» �'�► a p!!``o�� oppo -��@9�9t1HKaA.�• Aua-tlst 14, 2017 INSPECTION SEQUENCE BP# 18-4173 ADDRESS: 3536 Country Club Road BUILDING PERMIT Min Max Inspection Description Footer '/Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'1 Building Ceiling Grid 1000 Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) • REVISED: June 2014 ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final �BING PERMI"r AILI Min Max Inspection Description Rough Plumb Plumbing Underground Plumbing 2nd Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough P umbing Steam / Chill Water Rough Plumbing Final MECHANICAL PERMIT Min Max Ins ection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final ;� � ° .. � �l � _+: I Grant cuit Court & Com Seminole IL rn t #20181152176 Book 9226 Page: 1332; (1 PAGES)rRCD 10/6/2018t2:39:25 PM REC FEE $10.00 NTHISam-: J INHTRUMENT PREPARED eY: PP9r@ wllnq Addreac: rlZp NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: CEf,'rior EE)p CLERK Dr T). -c bH NT 7hL0y ANC,c6r r' kC;+L(r ICUURf SEMIr,CLE (c P v ,IURip By Date 4 uFyCLERK Parcel ID Number: 04-20-30-300-0030-0000 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement. GENNEErALDEBCRIPTION OF IMPROVEMENT: OWNER INFORMATION: Name: Sanford, City Of Address: 3536 Country Club Rd. Sanford FL 32771 Fee Simple Title Holder Of other than owner) Name: CONTRACTOR: Name: Jasper Bowling All -Tate Roofing, Inc. P.O. 32732 lot 7 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. In addition to himself, of To receive a copy of the Lienors Notice as Provided In Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I. SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in It are true to the best of my knowledge and belief. 0V ele w.rd 0m es NW FI statute 713.13(1)(#1 TIe owner must sign the rpLca of romna,certianl and no one also may be pelmitled to sign in Ns or ser stead: Slate athLa.fl W 4Lr County of (� The `fo{'re/ oolnn7g-1ffirs`ttru` um nt was a knowledged before me this � day of �KYty� g by ray T , Who is personally known to me Name or paean making a vont OR who has produced identification ❑ type of Identification produced: fVxrae4 Notary Pubec 51e1e d Fbdde 1 Re�Cca �� FF 67Nag ��j MY Cammbdon ry 9iprmlu e dr Expm oYi3rlO70 v P.O. Sox 1203 Geneva, FL 32732-1203 Phone: 407-349-2900 LMTED POWER OF ATTORNEY Date: October 8, 2018 I hereby name and appoint: Denissa Bowling an agent of: All-Tite Roofing, Inc. (Name of Ca®pa%) E-mail: AilTiteR@aol.com to be my lawful attomeyin- fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): ❑X All permits and applications submitted by this contractor. ❑ The specific permit and application for work located at: (Street Addms) Expiration Date for This Limited Power of Attorney: None License Holder Name: State License Signature of License Holder: STATE OF FLORIDA COUNTY OF Seminole Jasper Bowling CCC1326196 The foregoing instrument was acknowledged before me this $ day of Oct. 2018 _, by Jasper Bowling who is ?personally known to me or ? vdiiEas ro u londa drivers license identification and who did (did not) take an oath. rgnahue �ot,Ntary 'M" Rheanon Smith Mvcaeassia+Is{0E6 Print or type [tame yt /p EVRES:Iy114,E0 ?art.o• m,gynwa�ontmrse,� Notary Public -State of FL Commission No. FF 982395 My Commission Expires: April 14, 2020