Loading...
HomeMy WebLinkAbout4355 ST JOHNS PARKWAY 18-4355CITY OF SANFORD 0 0 T 2 5 2018 BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ 1<S -43s5- 24470.00 4355 ST JOHNS PKWY SANFORD, FL 32771 Historic District: Yes ❑ No ❑X Parcel ID: 28-19-30-5JB-0000-034A ❑ Commercial Type of Work: New ❑ Addition ❑ Alteration ❑ Repair x❑ Demo ❑ Change of Use ❑ Move ❑ Description of Work: Roof Coating on Commercial Building -FL i � --p3.4 — 94 Plan Review Contact Person: Phone: 321-363-3871 Rebecca Smith Title: Owner Fax: Email: info@xlr8roofing.com Property Owner Information Name MOLEE REALTY SOUTH LLC/ Anthony Molee Phone: Street: 4355 ST JOHNS PKWY City, State Zip: SANFORD, FL 32771 Name XLR8 Roofing Street: 485 Specialty Pt City, State Zip: Sanford, FL 32771 Name: Street: City, St, Zip: Bonding Company: Address: 407-328-0771 Resident of property?: Owner of Commercial Business Contractor Information Phone: 321-363-3871 Fax: State License No.: CCC1331278 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5'h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Signature of Contractor/Agent Dale Print Contractor/Agent's BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas[] Roof ❑ Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ APPROVALS: ZONING: ENGINEERING: COMMENTS: # of Heads UTILITIES: Flood Zone: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: FIRE: BUILDING: a Revised: June 30, 2015 Permit Application :p 'W"', RESECCASMITH �i MY COMMISSION#FF 969994 raF EXPIRES: March 10, 2020 `Bonded Thru Notary Public Und"riters Contractor/Agent is _ Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building ❑ Electrical ❑ Mechanical ❑ Plumbing❑ Gas[] Roof ❑ Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes ❑ No ❑ APPROVALS: ZONING: ENGINEERING: COMMENTS: # of Heads UTILITIES: Flood Zone: # of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes ❑ No ❑ WASTE WATER: FIRE: BUILDING: a Revised: June 30, 2015 Permit Application i ��T(-Gxalyttct_v�Y�a. _..._. s.R�.^su�_..t• .i_•_ , r f I i ��T(-Gxalyttct_v�Y�a. _..._. s.R�.^su�_..t• .i_•_ , - •- ._ .._ ;.,_.. _.. _. __. .. )^)1 .raid-'- 1.1'>�� • General Contractor/ Roofing Contractor e'oh►srRucnpN • Servicing Seminole, Orange, Volusla, Flagler & XLR8 Roofing & Construction, LLC Brevard counties 400 Specialty Pt, Sanford, Fl. 32771 321.363.3871 Owner's Name: owner's Address: xlr8roofEng.com 2 , > Ui.err FL Lic. No. CCC1331278 / CRC1331831 Owner's City, State, Zip: Owner's Phone: Owner's Alt. Phone: info@xlr8roofing.com Project Name & Address: Email: Project 3,G 1q- Jowls Rc.w AAV _J F1, I /WE, the Owner(s) of the premises described above authorize the Above named hereinafter referred to as "Contractor", to furnish all materials and labor necessary to roof and/or improve these premises according to the following terms, specifications and provisions: a. Description of the work and the materials to be used: ■ r h,,.,p -- _.. - - •tZG -- �i�•w - _.. --. ... Pull all permits __.. ■ p pass all inspections required by Florida Building ode Clean up entire property to ensure no nails or roofing debris Is left ■ Rotted wood replacement Is all unforseen and photo dace -m nt tion will be taken and Is billed after the fact as follows Rotted plywood replacement is per sheet at $65.00 • Rotted lx or 2x is per liner foot at $SSO - ea_�".__ • iA1tr� I�'.�Sw-/c-(ter-_�►i.L1._�4►f._?!.� 7 — We offer aNyear workmanship warranty. The manufacturer warranty Is-A"years 100% labor and materials y/,i Cyt � k - w6k f IrA0 Acts of God are not covered under the warranty (storm damage, hall, wind, fire, trees) — — -4i - __ °. ;•�-tnG�v _eS ..S .11 t/v,�-�•l__ —p�! t%.r - —..._. g C�i,v1C• b. Description of any areas that will NOT be worked on: THIS LIST OF SPECIFICATIONS MAY BE CONTINUED ON SUBSEQUENT PAGES (SEE PAGE NUMBER BELOW) - c. Payment: Contractor proposes to perform the above work, (subject to any additions and/or deductions niersu • •* to authorized change orders), for the Total Sum of$,� U iv Down Payment (if any) $ i 2,13`� PAYMENT DUE WHEN AMOUNT PAYMENTS TO BE MADE IN INSTALLMENTS AS FOLLOWS: 1, Contract is signed, before work Is started $ 2• Work iscomDleted S'1Z f��."� 3. 4. d. Commencement and Completion of Work: Substantial commencement of work shall mean either the physical delivery of materials onto the premises or the performance of any labor and shall be subject to any permissible delays as per provision (5) on the reverse side. Approximate Start Date: 3-5 weeks from acceptance e. Acceptance: This contract is approved and accepted. I (we) understand there are no oral agreements or understandings between the parties of this agreement. The written terms, provisions, plans (if any) and specifications In this contract is the entire agreement between the parties. Changes In this agreement shall be done by written change order only and with the express approval of both parties. Changes may Incur additional charges. Additional Provisions Of This Contract Are On The Reverse Side And May Be Continued On Subsequent Pages (see page number below). Read "Arbitration of Disputes" rovision on page two (2), provision 13 and the NOTICE following this provision. If you agree to arbitration, Initial on the line below the NOTICE w e indicated. Also, initial In the same place on EACH COPY of this contract. 7:5Cy You, the Buyer, may cancel this transaction at any time prior approved acc ted (owner) wwdate to midni ht f *9. *16: d b ' d a)gproved and ac pte (o r) / approved (contractor) date g o e tr ustness ay after the date of this transaction. See the attached Notice of Cancellation form for an explanation of this right. N TE• This contract may be withdrawn after 30 days from �74—t I' if not approved and signed by BOTH parties. Page ONE of 2 Total Pages ADDITIONAL PROVISIONS- Unless otherwise specified herein, the following additional provisions are expressly incorporated into this contract: 1. Contract, Plans, Specifications, Permits and Fees. The work described in ' this contract shall be done according to the plans and the plan specifica- tions (if any) except in the case of conflict when the provisions of this contract shall have control over both the plans and the plan specifications. All required building permits will be paid for by owner and obtained by Contractor. All other charges, taxes, assessments, fees etc., of any kind whatsoever, required by any government body, telephone or utility compa- ny or the like shall be paid for by Owner. 2.Installation. Contractor has the right to subcontract any part of, or all of, the work herein 3.Change Orders. Should Owner, construction lender, or any government body or inspector require any modification to the work covered under this contract, any cost incurred by Contractor shall be added to the contract price as extra work and Owner agrees to pay Contractor his normal selling price for such extra work. All extra work as well as any other modifications to the original contract shall be specified and approved by both parties in a written change order. All change orders shall became a part of this contract and shall be Incorporated herein. 4.Owners Responsibility: Insurance etc. Owner is responsible for the fol- lowing: (1) to see that all necessary water, electrical power, access to premises, and toilet facilities are provided on the premises. (2) to provide a storage area on the premises for equipment and materials. (3) to relocate and protect any item that prevents Contractor from having free access to the work areas such as but not limited to TV or radio antennas, vehicles, tools or garden equipment. In the event that Owner falls to relocate such items, Contractor may relocate these items as required but in no way is Contractor responsible for damage to these items during their relocation and during the performance of the work. (4) to obtain permission from the owner(s) of adjacent property(les) that Contractor must use to gain access to the work areas. Owner agrees to be responsible and to hold Contractor harmless and accept any risks resulting from the use of adjacent property(ies) by Contractor. (5) to correct any existing defects which are recognized during the course of the work. Contractor shall have no liability for correcting any existing defects such as, but' not limited to, dry rot, structural defects, or code violations. (6) to maintain property insurance with Fire, Course of Construction, all Physical Loss with Vandalism and Malicious Mischief clauses attached, In a sum at least equal to the contract price, prior to and during performance of this contract. If the project Is destroyed or damaged by an accident, disaster or calamity, or by theft or vandalism, any work or materials supplied by Contractor In reroofing or restoring the project shall be paid for by Owner as extra work. S.Delay. Contractor shall not be held responsible for any damage occa- sioned by delays resulting from: work done by Owners subcontractors, extra work, acts of owner or owners agent Including failure of owner to make timelyrogress payments or payments for extra work, shortages of material and/or labor, bad weather, fire, strike, war, governmental regula- tions, or any, other contingencies unforeseen by Contractor or beyond Contractor's reasonable control. 6.Surplus Materials and Salvage. Any surplus materials left over after this contract has been completed are the property of Contractor and will be removed by same. No credit is due Owner on, returns for any surplus materials because this contract is based upon a complete job. All salvage resulting from work under this contract Is the property of Contractor. 7.Cleanupp & Advertising. Upon completion, and after removing all debris and surplus materials, wherever possible, Contractor will leave premises In a neat, broom clean condition. Any debris consisting of dust, dirt, asphalt, or small bits of materials that settle into attics, garage areas, or any other area being worked over with open beam ceilings or no attic, is unavoidable and Contractor shall not be responsible for this cleanup. Contractor recom- mends that Owner lay out drop cloths to protect such areas wherever owner discovers debris infiltration. Owner hereby grants to Contractor the right to display signs and advertise at the job site for the period of time starting at the date of signing of this contract and 'continuing uninterrupted until fourteen (14) days past the date the job is completed and payment in full has been made. Owner grants Contractor the right to take "before" and "after" photos and to publish the project street address on a "references" list which may be given to prospective customers. 8.Concealed Damage & Dry Rot. Contractor will inform Owner of any dry rot or other sub -roof deterioration which is concealed and is discovered during the course of the work. Contractor is not responsible to repair any such discovered deterioration and any work done by Contractor to remedy such discovered deterioration will only be done as extra work In a written change order. 9.Termites, Pests & Hazardous Substances. Owner understands that Con- tractor is not qualified or licensed as an Inspector or abatement contractor for Hazardous Materialsas defined by the government), or for Pests (in- cluding Termites). Should any such hazardous substances or Pest be sus- pected to be present on the premises, it is the Owners' responsibility to arrange and pay for inspection and abatement. Contractor cannot certify or warrant your building as being free of hazardous substances or paste. 10.R' 0. Right to Stop Work and to Withhold Payment on labor and Materials. If any payment is not made to Contractor as perthis contract, Contractor shall have the right to stop work and keep the job idle until all past due progress payments are received. Contractor is further excused by Owner from paying any material, equipment and/or labor suppliers or any subcon- tractors (hereinafter collectively called "suppliers"), during the period that Owner is in arrears in making payments to Contractor for bills received during that same period. if these same "suppliers" make demand upon Owner for payment, Owner may make such payment on behalf of Contrac- tor and Contractor shall reimburse Owner for this amount at such time that Owner becomes current with Contractor for all past due payments. Owner is responsible to verify the true amounts owed by Contractor to these same "suppliers", prior to making payment on behalf of Contractor. Owner shall not be entitled, under any circumstances, to collect as reimbursement from Contractor any amount greater than that exact amount actually and truly owed by Contractor to these same "suppliers", for work done or materials supplied on Owner's job. 11. Collection. Owner agrees to pay all collection fees and charges including but not limited to all legal and attorney fees that result should Owner default inpayment of this contract. Overdue accounts are subject to inter- est charged at the rate of 18% per annum or at the highest rate allowed by law. 12. Legal Fees. In the event litigation or arbitration arises out of this con- tract, prevailing party(les) are entitled to all legal, arbitration, and attorney fees. The court or arbitrator shall not be bound to award fees based on any set, fee schedule but shall if it so chooses, award the true amount of all costs, expenses and attorney fees paid or incurred. 13. Arbitration of Disputes. Any controversy or claim arising out of or relating to this proposal/contract, or the breach thereof, shall be settled by arbitration in accordance with the applicable Con- struction Industry Arbitration Rules of the American Arbitration Association which are In effect at the time the demand for arbitra- tion is filed. A judgment upon the award rendered by the arbitrator(s) may be entered In any court having jurisdiction there- of. Any arbitration award shall be subject to correction and/or vacation for the reasons stated in the law. The arbitrator shall award reasonable attorneys fees and expenses to the prevailing party. After being given due notice, should any party fail to appear at or participate in the arbitration proceedings, the arbitrator shall make an award based upon the evidence presented by the party(les) who do (does) appear and participate. Notwithstanding Contractor's right to arbitrate, Contractor does not waive any of its lien rights. Venue for arbitration hearings shall be the project county unless otherwise agreed to by the parties. NOTICE: By initialing in the space below you are agreeing to have any dispute arising out of the matters included in the "arbitration of disputes" provision decided by neutral arbitration as provided by law and you are giving up any rights you might possess to have the dispute litigated in a court or jury trial. By initialing in the space below you are giving up your judicial rights to discovery and ap- peal, unless those rights are specifically, included In the "arbitra- tion of disputes" provision. If you refuse to submit to arbitration after agreeing to this provision, you may be compelled to arbitrate under the authority of the applicable laws. Your agreement to this arbitration provision is voluntary. We have read and understand the foregoing and agree to submit disputes arising out of the tters included in the "arbitration of disputes" provision to ne ral arbitration. I Agree to Arbitration: - initials of Owner) (Initials of Owner) FLORIDA HOMEOWNER'S CONSTRUCTION RECOVERY FUND PAYMENT MAY BE AVAILABLE FROM THE FLORIDA HOMEOWNER'S CONSTRUCTION RECOVERY FUND IF YOU LOSE MONEY ON A PROJECT PERFORMED UNDER CONTRACT, WHERE THE LOSS RESULTS FROM SPECIFIED VIOLATIONS OF FLORIDA LAW BYA LICENSED CONTRACTOR. FOR INFORMATION ABOUT THE RECOVERY FUND AND FILING A CLAIM, CONTACT THE FLORIDA CONSTRUCTION INDUSTRY LICENSING BOARD AT THE FOLLOWING TELEPHONE NUMBER AND ADDRESS: PHONE: (850) 487-1395 CONSTRUCTION INDUSTRY LICENSING BOARD CONSTRUCTION INDUSTRY RECOVERY FUND 2601 BLAIR STONE ROAD TALLAHASSEE, FLORIDA 32399-0783 "ANY CLAIMS FOR CONSTRUCTION DEFECTS ARE SUBJECT TO THE NOTICE AND CURE PROVISIONS OF CHAPTER SS8, FLORIDA STATUTES." Page TWO of _2_ Total Pages LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: l o I as ) IS, I hereby name and appoint: Paula Rodriguez / Whitney Brown an agent of: XLR8 Roofing & Construction LLC to be my lawful attorney-in-fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): IX The specific permit and application for work located at: 4355 ST JOHNS PKWY SANFORD, FL 32771 (Street Address) Expiration Date for This Limited Power of Attorney: 12/31/18 License Holder Name: David Hambley State License Number: CCC 1331278 Signature of License Holder: STATE OF FLORIDA COUNTY OF _5F.L{ " L 7 �J The foregoing instrument was acknowledged before me this,;9 day of axzm 2012L_, by D OV 1 i7 4 -Ir' M P)j Fry who is "ersonally known to me or o who has produced identification and who did (did not) take an oath. Signature (Notary Seal) RLbuf i} '45d rT}} Print or type name REBECCA SMITH MY COMMISSION II'p �299B94 Notary Public -St�at�er -o�f,� E%pIRES'.Marek 0 Commission No. i'tr' 1 e •ge„dedThruN0tA1 liaBnderv/d�' My Commission Expires: O— (Rev. 08.12) Grant Court & Comptroller Seminole County, FL Ie:1982; (1 PAGES) RCD: 10/18/2018 2:44:47 PM Prepared By Whitney Blown 400 Specialty Pt PermitNo Sanford FI 32771 Tell Parcel Number 28-19-30SJ13-0000-034A NOTICE OF COMMENCEMENT Slate of Florida The UNDERSIGNED hereby gives notice that inprovemenl will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information Is provided in this Notice of Commencement 1. Description of Property: (Legal description of the property, and street address if applicable.) W 112 OF LOT 34 SANFORD CENTRAL PARK PB 33 PG 64 TO 66 2. General description of improvement RE -ROOF 3. Owner Information (or Lessee Information If the Lessen contracted for the Improvement): a. Name: MOLEE REALTY SOUTH LLC / ANTHONY MOLEE Address: 4355 ST JOHNS PKWY SANFORD, FL 32771 b. interest in property: c Name and address of fee simple titleholder Of other than owner): 4. Contractor Information: a. Name: XLR8 Racing d Consbudion, LLC Address: 400 Specialty PcinL Sanford, FL 32771 b. Contractors phone number. 321-363.3871 5. Surety Of applicable, a copy of the payment bond 5 attached): a. Name: Address: b. Phone number: c. Amount of bond: $ .0D 6. Lender Information: a. Name: Address: b. Lenders phone number. 7. Persons within the State of Florida designated by Owner upon whom nrotices or other documents may be served as prodded by Section 713.13(1)(e)% Florida Stature: a. Name: Address: CERTIFIEDCOPY GRANTMALOY CLERK RCUiTCOURT e: �` AND COIV, TR LER t r• 1T, FLORIDA Q. `Y V SENdNOIE BY TY CLERK Date FOR CLERK'S OFFICE USE ONLY b. Phone numbers of designated persons: 8. In addition to hbnsalt Owner designates, a. Name: of to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b), Florida Statutes. b. Phone number 9. Expiration dale of Notice of Commencement (Nem7cafon dab is 7 year born Ne dab ofnerndrg unless a dEforadda isspecifleft. WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSUL YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. / SlgnaloysTibef0ffice State of , k M, County of The forgoing instrument was acknowledged beloeme this day of 20 by (TYpeofauawdty... e.g. o9xer, suers. aalbney In fact) � / Sgnatura of Notary Pu is—Slate ofFlloride Personally Known _ OR --Z Produced ID iq0ftcc Notary Public State of Florida Paulo J Rodriguez +� 3� My Commission GG 199671 yq yde expires 03252022 PdnL Type ars p emeo Notary u c r Type of to Produced NJ SVM I4ilkl�b MQ 135 �53i� aql� Iti 9/25/2018 Detail by Entity Name DIVISION OF CORPORATIONS rgr� r( r1 fir . i an (4 if ifiI.Y1111f, vf Florida we/Wir Department of State 1 Division of Corporations / Search Records / Detail By Document Number 1 Detail by Entity Name Florida Limited Liability Company MOLEE REALTY SOUTH, LLC EjUng Information 2017 Document Number L08000000959 FEI/EIN Number 42-1752112 Date Filed 01/03/2008 Effective Date 01/03/2008 State FL Status ACTIVE Principal Address 4355 ST. JOHN'S PARKWAY SANFORD, FL 32771 fling ss 4355 ST. JOHN'S PARKWAY SANFORD, FL 32771 &gistered Agent Name & Address MOLEE, ANTHONY 4355 ST. JOHN'S PARKWAY SANFORD, FL 32771 Authorized Person(e) Detail Name & Address Title MGRM MOLEE, ANTHONY 4355 ST. JOHN'S PARKWAY SANFORD, FL 32771 Annual Reports Report Year Filed Date 2016 02/20/2016 2017 01/09/2017 2018 01/12/2018 Document Images I01/1212018 --ANNUAL REPORT View image in PDF format I I http://search.sunbiz.org/inquiry/CorporationSearch/SearchResultDetail?inquirytype=EntityName&directionType=Initial&searchNameOrder=MOLEERE... 112 9/25/2018 petail by Entity Name 01/0912017 — ANNUAL REPORT View image in PDF format J 02/20/2016 -- ANNUAL REPORT View image in PDF format 01/2812015 -- ANNUAL REPORT View image in PDF format 01/09/2014 -- ANNUAL REPORT View image in PDF format I 01/24/2013 — ANNUAL REPORT View image in PDF format 041180012 -- ANNUAL REPORT View image in PDF format 02/01/2011 —ANNUAL REPORT View image in PDF format 02/16/2010 -- ANNUAL REPORT View image in PDF format 02/0312009 -- ANNUAL REPORT View image in PDF format 01/03/2008 -- Florida Limited Liability, View image in PDF format flotu7.t Ueltai file fit pit Sthtt DIV[ stoll of (CotJ uIatlotts .. 212 GREEK TECHNICAL SERVICES, LLC Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6r" EDITION (2017) Manufacturer: GACO WESTERN, LLC Specification Issued April 19, 2018 200 West Mercer Street, Suite 202 ASTM D 6083 Acrylicquick-set elastomeric coating that is brush, roller orspray-applied. Seattle, WA 98119 ASTM D 6694 Silicone elastomeric coating that is brush, roller orspray-applied. (800)331-0196 ASTM D 6694 Silicone solvent -free, single -component, moisture -cured, waterproof elastomeric coating that is brush, roller orspray-applied. www.paco.com ASTM D 6694 Silicone solvent -free, single -component, moisture -cured, waterproof elastomeric coating that is brush, roller orspray-applied. Manufacturing Plants: Waukesha, WI PERMIT # 1 Silicone elastomeric coating that is brush, roller orspray-applied. Quality Assurance: UL LLC (QUA1743) SCOPE Category: Roofing Subcategory: Cements -Adhesives-Coatings Code Sections: 1507.14.3,1507.15.2 �' CE Properties: Physical Properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) GWI-024-02-02 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-026-02-01 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-042-02-01 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-043-02-01 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-044.02-01 ASTM D 6694 2008 PRI Construction Materials Technologies (TST5878) GWI-045-02-01 ASTM D 6083 2005e01 PRODUCT DESCRIPTION Products Specification Description GacoFlex A-31 ASTM D 6083 Acrylicquick-set elastomeric coating that is brush, roller orspray-applied. GacoFlex S-10 ASTM D 6694 Silicone elastomeric coating that is brush, roller orspray-applied. GacoFlex S-20 ASTM D 6694 Silicone solvent -free, single -component, moisture -cured, waterproof elastomeric coating that is brush, roller orspray-applied. GacoFlex 5-21 ASTM D 6694 Silicone solvent -free, single -component, moisture -cured, waterproof elastomeric coating that is brush, roller orspray-applied. GacoRoof GR -16 I ASTM D 6694 1 Silicone elastomeric coating that is brush, roller orspray-applied. GW18002 FL14724-R4 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC APPLICATION The following nates shall be observed when using the application tables below: 1. All surfaces shall be repaired, clean, dry,and fre a of debris prior to application. 2. Roof coating may be spray, brush or roller applie�. 3. Applications are valid for new and existing roof systems. GACO WESTERN, LLC GacoFlex Roof Coatings Application of GacoFlex A-31 Substrate New or Existin Minimum Application Rate Spray Polyurethane Foam Roofs Gacol z i A-31 applied in three (3) coats (base, intermediate and top) at a minimum rate of 1.25 gal/100 ft' per coat Application o. GacoFlex S-10 Substrate New or Existing) Minimum Application Rate Primed with GacoFlex E-5320 Primer at a rate of 0.3 ga11100 ft2 followed by one of the following: Acrylic Coatings -One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gal/100ft2 -Two (2) coats (base and lop) of GacoFlex S-10 applied at a minimum rate of 1.1 ga11100ft' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.4 gal/1 00 ft' followed by one of the following: BUR Membranes - Smooth -surfaced -One coat of GacoFlex 5-10 applied at a minimum rate of 2.2 ga11100112 -Two (2) coats (base and top) of GacoFlex S-10 applied at a minimum rate of 1.1 gall100ft' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft' followed by one of the following: Galvanized Steel Metal Panels -One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gavl00ft2 -Two (2) coats (base and top) of GacoFlex S-10 applied at a minimum rate of 1.1 gal/100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 ga11100 ft2 followed by one of the following: KEE Single -Ply Membrane -One coat of GacoFlex S-10 applied at a minimum rate of 2.2 gaIl100ft -Two (2) coats (base and top) of GacoFlex 5-10 applied at a minimum rale of 1.1 gal/100ft' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/1 00 112 followed by one of the following: PVC Single -Ply Membranes -One coat of GacoFlex 5-10 applied at a minimum rate of 2.2 ga111001112 -Two (2) coats (base and top) of GacoFlex 5-10 applied at a minimum rate of 1.1 ga11100ft' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 ft2 followed by one of the following: SBS Modified Bitumen Membranes - Granule -surfaced -One coat of GacoFlex 5-10 applied at a minimum rate of 2.2 ga11100ft -Two (2) coats (base and top) of GacoFlex 5-10 applied at a minimum rate of 1.1 gal/100(12 per coat Applied according to one of the following: Spray Polyurethane Foam Roofs -One coat of GacoFlex S-10 applied at a minimum rate of 2.2 ga11100ft -Two (2) coats (base and top) of GacoFlex 5-10 applied at a minimum rate of 1.1 gal/100112 per coat 2 of This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK TECHNICAL SERVICES, LLC GACO WESTERN, LLC GacoFlex Roof Coatings Application of GacoFlex S-20 Substrate New or Existing) Minimum Application Rate Primed with GacoFlex E-5320 Primer at a rale of 0.3 gal/100 ft' followed by one of the following: Acrylic Coatings -One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gaV100ft2 -Two (2) scats (base and top) of GacoFlex S-20 applied at a minimum rate of 0.75 gaYl00ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/1 00 ft2 followed by one of the following: APP Modified Bitumen Membranes - Granule -surfaced -One coat of GacoFlex 5-20 applied at a minimum rate of 1.5 ga11100ft2 -Two (2) coats (base and top) of GacoFlex 5-20 applied at a minimum rate of 0.75 ga11100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.5 ga11100 1112 followed by one of the following: APP Modified Bitumen Membranes - Smooth -surfaced -One coat of GacoFlex 5-20 applied at a minimum rate of 1.5 ga11100ft2 -Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum rate of 0.75 gal/100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.4 gaV100 ft' followed by one of the following: BUR Membranes - Smooth -surfaced -One coat of GacoFlex 5-20 applied at a minimum rate of 1.5 gal/100ft' -Two (2) coats (base and top) of GacoFlex 5-20 applied at a minimum rate of 0.75 gaV100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/1 00 ft2 followed by one of the following: EPDM Single -Ply Membranes -One coat of GacoFlex S-20 applied at a minimum rate of 1.5 gall100112 -Two (2) coats (base and top) of GacoFlex 5-20 applied at a minimum rate of 0.75 gal/100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft' followed by one of the following: Galvanized Steel Metal Panels -One coat of GacoFlex 5-20 applied at a minimum rate of 1.5 ga11100112 -Two (2) coats (base and top) of GacoFlex 5-20 applied at a minimum rete of 0.75 gaV100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 ga1I10011' followed by one of the following: KEE Single -Ply Membrane -One coat of GacoFlex S-20 applied at a minimum rate of 1.5 ga11100112 -Two (2) coats (base and top) of GacoFlex 5-20 applied at a minimum rate of 0.75 gal/100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 112 followed by one of the following: PVC Single -Ply Membranes -One coat of GacoFlex S-20 applied at a minimum rate of 1.5 ga11100ft2 -Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum rate of 0.75 ga11100112 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.5 ga11100 ft' followed by one of the following: SBS Modified Bitumen Membranes - Granule -surfaced -One coat of GacoFlex S-20 applied at a minimum rale of 1.5 ga11100ft2 -Two (2) coats (base and top) of GacoFlex 5-20 applied at a minimum rale of 0.75 gall100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/1 00 ft2 followed by one of the following: SBS Modified Bitumen Membranes - Smooth -surfaced -One coat of GacoFlex 5-20 applied at a minimum rate of 1.5 gal/1001912 -Two (2) coats (base and top) of GacoFlex 5-20 applied at a minimum rate of 0.75 gat/1001t2 per coat Applied according to one of the following: Spray Polyurethane Foam Roofs -One coat of GacoFlex 5-20 applied at a minimum rate of 1.5 gal/1001112 -Two (2) coats (base and top) of GacoFlex 5-20 applied at a minimum rate of 0.75 gat/100ft2 per coat GW18002 FL14724-R4 Page 3 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC GACO WESTERN, LLC GacoFlex Roof Coatings Application of GacoFlex 5-21 Substrate Minimum Application Rate New or Existing) Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 ft' followed by one of the following: APP Modified Bitumen Membranes - Granule -surfaced -One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100112 -Two (2) coats (base and lop) of GacoFlex S-21 applied at a minimum rate of 0.75 gal/100ft' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gat/100 ft' followed by one of the following: EPDM Single -Ply Membranes -One coal of GacoFlex S-21 applied at a minimum rate of 1.5 ga1110011' -Two (2) coals (base and top) of GacoFlex 5-21 applied at a minimum rate of 0.75 gaU100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft2 followed by one of the following: Galvanized Steel Metal Panels -One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/t00ft2 -Two (2) coats (base and top) of GacoFlex 5-21 applied at a minimum rate of 0.75 gal/100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaI1100 11:2 followed by one of the following: Hypalon Single -Ply Membranes -One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ft2 -Two (2) coats (base and top) of GacoFlex 5-21 applied at a minimum rale of 0.75 gaV100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gal/100 ft2 followed by one of the following: KEE Single -Ply Membrane -One coat of GacoFlex S-21 applied at a minimum rale of 1.5 gal/100ft2 -Two (2) coats (base and top) of GacoFlex 5-21 applied at a minimum rate of 0.75 gal/100112 per coat Primed with GacoFlex E-5320 Primer at a rale of 0.3 gaU100 ft2 followed by one of the following: PVC Single -Ply Membranes -One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ft2 -Two (2) coats (base and top) of GacoFlex 5-21 applied at a minimum rate of 0.75 gal/100f12 per coat Primed with GacoFlex E-5320 Printer at a rate of 0.5 gal/100 W followed by one of the following: SBS Modified Bitumen Membranes - Granule -surfaced -One coal of GacoFlex S-21 applied at a minimum rate of 1.5 ga11100ft2 -Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum rate of 0.75 gaV100ft' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 ft2 followed by one of the following: SBS Modified Bitumen Membranes - Smooth -surfaced -One coat of GacoFlex 5-21 applied at a minimum rate of 1.5 gal/100ft2 -Two (2) coats (base and top) of GacoFlex S-20 applied at a minimum rate of 0.75 gaU100ft2 per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaV100 ft2 followed by one of the following: TPO Single -Ply Membranes -One coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100112 -Two (2) coats (base and top) of GacoFlex S-21 applied at a minimum rate of 0.75 gaV100ft2 per coat Applied according to one of the following: Spray Polyurethane Foam Roofs -One (coat of GacoFlex S-21 applied at a minimum rate of 1.5 gal/100ft2 1(2) -Two coats (base and top) of GacoFlex 5-21 applied at a minimum rate of 0.75 gal/100ft2 per coat GW18002 FL14724-R4 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I GREEK TECHNICAL SERVICES, LLC GACO WESTERN, LLC GacoFlex Roof Coatings Application of GacoRoof GR -16 Substrate New or Existing) Minimum Application Rate Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaill00 ft' followed by one of the following: Acrylic Coatings -One coat of GacoRoof GRA6 applied at a minimum rate of 2 ga11100ft2 -Two (2) coats (base and top) of GacoRoof GR -16 applied at a minimum rale of 1 gal/100ft' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.4 gal/1 00 ft' followed by one of the following: BUR Membranes - Smooth -surfaced -One coat of GamRoof GR -16 applied at a minimum rate of 2 gaV100ft2 -Two (2) coats (base and top) of GacoRoof GR -16 applied at a minimum rate of 1 ga1110011' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 gaV100 ft' followed by one of the following: EPDM Single -Ply Membranes -One coat of GacoRoof GR -16 applied at a minimum rate of 2 gall100fl' -Two (2) coats (base and top) of GacoRoof GR -16 applied at a minimum rate of 1 gal/100ft' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.3 ga1I100 ft' followed by one of the following: Galvanized Steel Metal Panels -One coat of GacoRoof GR -16 applied at a minimum rate of 2 gaVlooft2 -Two (2) coats (base and top) of GacoRoof GRA6 applied at a minimum rate of 1 gal/100ft' per coat Primed with GacoFlex E5320 Primer at a rate of 0.3 gaV100 ft' followed by one of the following: KEE Single -Ply Membrane -One coat of GacoRoof GRA6 applied at a minimum rale of 2 gal/100ft' -Two (2) coats (base and top) of GacoRoof GRA6 applied at a minimum rate of 1 gal/10011' per coat Primed with GacoFlex E-5320 Primer at a rale of 0.3 gal/100 ft' followed by one of the following: PVC Single -Ply Membranes -One coat of GacoRoof GRA6 applied at a minimum rate of 2 gal/100ft2 -Two (2) coats (base and top) of GamR00f GRA6 applied at a minimum rate of 1 gal/10011' per coat Primed with GacoFlex E-5320 Primer at a rate of 0.5 gal/100 ft' followed by one of the following: SBS Modified Bitumen Membranes - Granule -surfaced -One coat of GacoRoof GRA6 applied at a minimum rale of 2 gal/1 OOft' -Two (2) coats (base and top) of GacoRoof GR -16 applied at a minimum rate of 1 gal/10011' per coat Applied according to one of the following: Spray Polyurethane Foam Roofs -One coat of GacoRoof GRA6 applied at a minimum rate of 2 gal/100ft' -Two (2) coats (base and top) of GacoRoof GRA6 applied at a minimum rate of 1 gal/100ft' per coat GW18002 FL14724-R4 Pads 5 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ®CREEK TECHNICAL SERVICES, LLC LIMITATIONS GACO WESTERN, LLC GacoFlex Roof Coatings 1. Fire classification is not within the scope of this evaluation. 2. Structural integrity of the roofing substrate or assembly is not within scope of this evaluation. Refer to the appropriate product approval for installation of these components within an Approved roof assembly. 3. Installation of the evaluated products shall be in strict compliance with this evaluation report, the FBC, and the manufacturer's published installation instructions. In the event of conflict, the more restrictive and FBC compliant installation shall be enforced. 4. This product shall not be applied in inclement weather conditions. 5. This product shall not be applied over asphaltic shingles, metal shingles, fiber -cement shingles, quarry slate, cement or clay roofing tile, or wood shingles or shakes. 6. This product may be used may be used as described in other current FBC product approval documents. 7. Refer to manufacturer's published instructions for proper storage and shelf life considerations. 8. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 1320-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest have demonstrated compliance with the Florida Building Code, 61° Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. 011111111111 R ?, ENS No 74021 = 2018.04.19 17:46:35 STATE O -04'00' :O•<u: IK%c( O R 10P'����`� Zachary R. Priest, P.E. �Of, S;ONA�?�`�` Organization No. ANE9641Florida Registration No. 021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor wilt it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a fine ncial Interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor wit acquire, a fina4ial interest in any other entity involved in the approval process of the product. GW18002 END OF REPORT FL.14724-R4 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. INSPECTION SEQUENCE BP# 18-4355 ADDRESS: 4355 St. Johns Pkwy BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof D In Frame Insulation Rough Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com'l) Building Ceiling Grid 1000 Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) REVISED: June 2014 ELECTRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole Electric Final PLUMBING PERMIT Min Max Inspection Description Rough Plumb Plumbing Underground Plumbing 2"d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final MECHANICAL PERMIT Min Max Inspection Description Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap Mechanical Final