Loading...
HomeMy WebLinkAbout2358 Blue Grouse Ln 18-2819 New Construction SFHt 9'-4" BRG. HT, 8'-0" HDR. HT. 0'-0" FIN. FLR. x O A-** _ 11'-4" BRG. HT. CD F @ENTRY D m 9'-4" BRG. HT. cra J 8'-0" HDR. HT..� n i 3/8" TEXTURED CEMENTITIOUS FINISH OVER C.M.U. (TYP.) 0'-0" FIN. FLR. 4 12 �6 -- - - - --- ALL HORIZONTAL & VERTICALS - CONTROL JOINTS PER ASTM 1063 12 61 Left Elevation "C" (Standard) SCALE: 1/8" = TV (11x17) 1/4" = TV (22x34) Right Elevation "C" (Standard) SCALE 1/8" = 1'-0" (11x17) 1/4" = 1'•0" (2204) 1 DET. 3 7/8" TEXTURED CEMENTITIOUS FINISH ON METAL LATH OVER 7/16" OSB. SHEATHING (TYP.) � 11'4" BRG. HT. Y @ ENTRY 9'-4" BRG. HT. y .7 N 8'-0" HDR. HT. 3/8" TEXTURED CEMENTITIOUS FINISH OVER C.M.U. (TYP.) F 0'-0" FIN. FLR. I 11'4" BRG. HT. @ ENTRY 9'-4" BRG. HT. 8'-0" HDR. HT. 0'-0" FIN. FLR. A-** rn u- ►► O OBJ` r * Q O; Z U �• �j z ~O� CD cra r� � � z a C:) r' r Q o O E r- M O U J C6 C Z m Q W N r- cn o � N CD N Q.amcN E a cu (n o c r�, O r 0 E0 U-) Mcu a 00 Q Q. LL o c MWz > W W 0 4Z J a CD a iE o N w 0 O� o N W w �o Q -- z Q z 0 Li 0 0 a► N o � oQ 1T� d J m� E M a o< a O L "_ 0 LLL Z:2 Q� Ln fu 3: m o z0 C n CD cn '�t Ln(n wow M lV w a w L Cn F-- a� o� vS N zU) a ``' J [if 0-0- X W W N W W H - Z Z O z_ N cn a LLJ F- 0 m Z0 Z i ra O : QV) o a (� M LIJ 0 0 -0 ,�-� O) .� cf� fu 00 N aLn � L w FC.F M n n w O U)_. cu cl)LL = O 'L O -0 z> Gj V) -p .0B O O Q w Ln O a z r :J Q J Z J n n . Y J) r Y N n ISSUE DATE 06/06/2018 Ipn REVISIONS r-- PROJECT: 18-0313 r SCALE: AS NOTED i DRAWN BY: JML & JFT DESIGNED BY: MJS ELEVATIONS "C" L J 04.0 (OPT) PRE -WIRE AF CLG. FAN/LITE � I V.P. O V.P. G (OPT) PRE -WIRE CLG. FAN/LITE 0 C.M.S.D. (OPT) PRE -WIRE CLG. FAN/LITE WP I' GFI Af-'W AF W I i 4 RECESS LIGHTS F I (OPT) PRE -WIRE CLG. FAN/LITE 1 I� i (OPT) PRE -WIRE CLG. FAN/LITE i AF n 4 RECESS_ LIGHTS � I (OPT) PRE -WIRE CLG. FAN/LITE — Aj� I -d I S.D. -- — — /' \ " / C.M.S.D. 1 � 42" AF j DGFI PENDANT LIGHT PRE -WIRE r (3-TYP.) U/C GFCI FOR DISPOSAL & DW. LOW -r GFI LOW II i o�� o l / GGrI f � EXTRA DUTY A911 J GG'FiF;E� 42" _.. 42" 42" 1 1.� 42" a 42" u GFI 20 AMP. DED. AF � GFI OUTLET @ 42' �_�-- A.F.F. AF GFI @ 42' �1 / PIr GFI @ GARAGE CLG. ---------------------- AF --------------AF PFI �2' I ; Electrical Plan "A,B,C" (Opt Master Bath) SCALE 1/8" = 1'-0" (11x17) 1/4" = 1'•0" (22x34) OPTIONAL OVERHEAD SERVER SAME AS UNDERGROUND 200 AMP SERVICE AMP METER MAIN DISC. TYP. ELECTRICAL UNDERGROUND PANEL SERVICE BY (20 CIRCUITS) POWER CO. 4/0 SCR AL. #2 -GROUND TO (2) 5/8" RODS (6' APART) ALS( SERVICE TO BE BONDED TO FOOTING STEEL GENERAL NOTES KEY: 1. BUILDER TO VERIFY EXACT LOCATION OF FLOOR NOTE: 8. EXCEPTIONS TO THE GFCI STIPULATION WILL BE ALL ELECTRICAL WORK AND MATERIAL PROVIDED SHALL COMPLY WITH THE FLORIDA ALLOWED ONLY IF ALLOWED PER CURRENT BUILDING CODE. (2017) THE ABOVE ELECTRICAL LAYOUT IS FOR BID PURPOSE ONLY. NFPA / NEC. 9. OUTLETS LOCATED IN THE LAUNDRY ARE TO BE GFCI AND AFCI PROTECTED. 200 AMP ELECTRICAL RISER 10 OUTLETS LOCATED WITHIN 6' 0" OF A W ET AREA OUTLETS IN FIELD. NEMA 3 2. ALL OUTLETS ARE TO BE AFCI PROTECTED. SEE FLOOR PLAN FOR FUSE SIZE CHANDELIER = 0 A/C DISC. 3. ALL 15A AND 20A 120V BRANCH CIRCUITS WILL BE 11. ALL OUTLETS OVER COUNTERTOPS TO BE 42" AFCI PROTECTED. #14 COPPER TO LIGHTS AND OUTLETS 4. ALL 15A AND 20A 120V BRANCH CIRCUITS -0 #10 COPPER TO WATER HEATER #8 COPPER TO RANGE > LOCATED IN THE GARAGE AND LAUNDRY WILL BE o #8 TO A/C 12. ALL SMOKE/CARBON MONOXIDE DETECTORS GFCI PROTECTED. 5 5. ALL GARAGE BAYS WILL HAVE DEDICATED GFCI ARE TO BE HARD WIRED, INTERCONNECTED AND r14 OUTLET. Q 6. ALL OUTLETS LOCATED IN THE KITCHEN AND AFCI PROTECTED. 8 - BATHROOMS ARE TO BE GFCI PROTECTED. DESIGNED BY: MJS 7. DW. AND GARBAGE DISPOSAL ARE TO BE GFCI ELECTRICAL LAYOUT PROTECTED. NOTE: 8. EXCEPTIONS TO THE GFCI STIPULATION WILL BE ALL ELECTRICAL WORK AND MATERIAL PROVIDED SHALL COMPLY WITH THE FLORIDA ALLOWED ONLY IF ALLOWED PER CURRENT BUILDING CODE. (2017) THE ABOVE ELECTRICAL LAYOUT IS FOR BID PURPOSE ONLY. NFPA / NEC. 9. OUTLETS LOCATED IN THE LAUNDRY ARE TO BE GFCI AND AFCI PROTECTED. 200 AMP ELECTRICAL RISER 10 OUTLETS LOCATED WITHIN 6' 0" OF A W FLUORESCENT LIGHT N w ELECTRICAL PANEL Z 00 CHIME 0 DOOR BELL / GARAGE DOOR SWITCH =DISCONNECT L-= SWITCH 3 ELECTRICAL METER z 0 S.D. SMOKE DETECTOR o 0 C.M.S.D. CARBON MONOXIDE / SMOKE DETECTOR Lj CEILING FAN W - it ET AREA ISSUED TE 06/06/2018 ARE TO BE GFCI PROTECTED. CHANDELIER = 0 C SPOT LIGHT o u 11. ALL OUTLETS OVER COUNTERTOPS TO BE 42" O CL A.F.F. (U.N.O.). -0 > N o c 12. ALL SMOKE/CARBON MONOXIDE DETECTORS FAN / LIGHT COMBINATION 0 5 o ARE TO BE HARD WIRED, INTERCONNECTED AND r14 DRAWN BY: JML & JFT Q w Ln AFCI PROTECTED. 8 - S DESIGNED BY: MJS O JUNCTION BOX 13. 8'-0" HEIGHT VANITY LIGHTS IN MASTER ELECTRICAL LAYOUT 0 L.V. LOW VOLTAGE - V.P. VAPOR PROOF ° BATHROOM AND 7'-0" IN ALL OTHER BATHROOMS. A.F. j ARC FAULT PROTECTION O: O ~ NOTES: a T_ M O • THIS DIAGRAMMATIC PLAN IS INTENDED TO o (� SHOW LIGHTING AND CONVENIENCE OUTLETS N J uj ONLY. IT IS THE ELECTRICAL CONTRACTORS , 5LL RESPONSIBILITY TO VERIFY THE REQUIREMENT a (n vi T— Co AND LOCATIONS OF ALL ELECTRICAL C T. -r" fl--C:CD EQUIPMENT, (INCLUDING KITCHEN EQUIPMENT) o N I "D uj AND PROVIDE AND INSTALL COMPLETE Q Q 04 E ELECTRICAL SERVICE AS REQUIRED PER NFPA, a (/1 (V NEC, FBC CODES AND ALL REIGNING +r N (o �. O MUNICIPALITY CODES, STANDARDS AND W N q I'-- Cl) ORDINANCES. o } O O 0 • LOCATION OF FIXTURES AND / OR OUTLETS ARE w `. SUGGESTED LOCATIONS AND MEET MOST LOCAL Lo CU X CODE REQUIREMENTS. ADDITIONS OR i t Q ADJUSTMENTS MAY BE MADE BETWEEN THE a LL Of OWNER AND BUILDER IN THE FIELD. o Z C U) • ALL ELECTRICAL WORK AND APPLIANCES ARE IN w FULL COMPLIANCE WITH N.F.P.A., N.E.C., F.B.C. w z 6TH EDITION (2017) RESIDENTIAL, AND ALL o g APPLICABLE LOCAL STANDARDS, CODES, AND a ORDINANCES. a Co • VARIOUS SYMBOLS ON ELECTRICAL LEGEND . t w MAY OR MAY NOT BE USED ON THIS PLAN. 0 0 O `� w Of U 4 T Q ELECTRICAL KEY: z I 0 a CEILING MOUNTED LIGHTCn � _ }-C PULL CHAIN LIGHT 0- 'I' P o ¢ (� a E M RECESSED LIGHT m o Y C)�, -gyp 2 - O '�-(�/1 � WALL MOUNTED LIGHT � 00- U- WALL WASH RECESSED Z DUPLEX RECEPTACLE Z o m VPCD Co � 00 M fu V) 220 V RECEPTACLE 3FI w N o 4!) 1/2 HOT, 1/2 SWITCHED Qw r� J AWP WATER PROOF RECEPTACLE W \ FLOOR RECEPTACLE �N PRE -WIRE FOR CLG. FAN as JGFI w GROUND FAULT INTERRUPT w O 8 WALL SWITCH z Z Q 8, 3 -WAY SWITCH o 8D DIMMER SWITCHQ j o0 c) LA OM N TELEPHONE JACK Q i 00N H CABLE JACK 2o z d V c N M Ln ® PRE -WIRE GARAGE DOOR OPENER a FLUORESCENT LIGHT N w ELECTRICAL PANEL Z 00 CHIME 0 DOOR BELL / GARAGE DOOR SWITCH =DISCONNECT L-= SWITCH 3 ELECTRICAL METER z 0 S.D. SMOKE DETECTOR o 0 C.M.S.D. CARBON MONOXIDE / SMOKE DETECTOR Lj CEILING FAN W - it WALL WALL SCONCE m W ISSUED TE 06/06/2018 CHANDELIER = 0 C SPOT LIGHT o u REVISIONS O CL > -0 > N o c C FAN / LIGHT COMBINATION 0 5 o V, r14 DRAWN BY: JML & JFT Q w Ln O 8 - WALL WALL SCONCE m W ISSUED TE 06/06/2018 CHANDELIER = SPOT LIGHT o REVISIONS FLUSH MOUNT FLUORESCENT LIGHT � — FAN / LIGHT COMBINATION 0 PROJECT: 18-0313 g GARBAGE DISPOSAL MOTOR Q SCALE: AS NOTED DRAWN BY: JML & JFT a ® SPEAKER S DESIGNED BY: MJS O JUNCTION BOX ELECTRICAL LAYOUT 0 L.V. LOW VOLTAGE - V.P. VAPOR PROOF ° 05.1 A.F. j ARC FAULT PROTECTION INSTALLATION NOTES: 1. THROUGHOUT INSTALLATION, KEEP THE WINDOW JAMBS PLUMB AND SQUARE. KEEP HEAD AND SILL LEVEL AND SQUARE. MAKE SURE HEAD AND SILL ARE NOT CROWNED UP OR DOWN. 2. CONSTANTLY CHECK WIDTH AT MEETING RAILS (i.e. DOUBLE HUNGS) TO AVOID "BOWED OUT' INSTALLATION. 3. APPLY GENEROUS BEAD OF CAULK ALONG INTERIOR SURFACE OF NAILING FIN ON ALL SIDES PRIOR TO SETTING WINDOW INTO OPENING. 4. PLACE 1/4" SHIMS AT SILL CORNERS AND SET WINDOW INTO SHIMS. CENTER THE WINDOW IN THE OPENING ALLOWING A 1/4" GAP BETWEEN WINDOW AND FRAMING MATERIAL ON EACH SIDE. WHEN INSTALLATION IS COMPLETE, THESE SHIMS MAY BE REMOVED. 5. INSTALL FASTENERS (STRAIGHT, NOT ANGLED) IN EVERY OTHER FASTENER SLOT STARTING AT THE MIDDLE OF THE WINDOW. FASTENER MUST BE EMBEDDED INTO SOLID WOOD A MINIMUM OF 111. KEEP WINDOW LOCKED UNTIL ALL SIDES ARE SECURED. 6. CAULK OVER FASTENERS AND ANY FASTENER SLOTS NOT USED. 7. CAULK OUTSIDE PERIMETER OF INSTALLED WINDOW. 8. INSULATE AROUND PERIMETER WITH BATT TYPE INSULATION. DO NOT USE EXPANDABLE FOAM. THE USE OF EXPANDABLE FOAM WILL VOID WARRANTY. 9. FOR ANY INSTALLATION FINISHED WITH BRICK OR STONE, ALLOW 1/4" GAP AT SILL BETWEEN STRUCTURE AND WINDOW. THEN, CAULK THIS GAP. 10. CAULK GAP BETWEEN INSTALLED WINDOW EXTERIOR PERIMETER AND J -CHANNEL (OR BRICK OR OTHER EXTERIOR FINISHING MATERIAL WHICH SURROUNDS WINDOW). FLASHING SEQUENCING: • APPLY BOTTOM PIECE OF SELF-ADHESIVE TYPE FLASHING OVER ALL OF ROUGH OPENING. • SET WINDOW UNIT. • APPLY 2ND BOTTOM PIECE OF SELF-ADHESIVE TYPE FLASHING OVER NAILING FIN AND BLDG PAPER. • APPLY SIDE STRIPS OF SELF-ADHESIVE TYPE FLASHING. • APPLY TOP PIECE OF SELF-ADHESIVE TYPE FLASHING. NOTE: SELF-ADHESIVE TYPE FLASHING IS A GENERIC TERM. SEE SPECIFICATIONS FOR MATERIAL TO BE USED. CONCRETI HEADER 0 LINTEL PC EXP. S7 PC ANCHC STRIP GLS. BLK. PC PANEL REINFOR. SEALANT PC ANCHC I" EXP. BOI PER ANCH MORTAR ASPHALT EMULSION CONIC. BL( WALL EXTERIOR PANEL ANCHOR CONSTRUCTION PC PANEL REINFORCING (TOP): USED IN PANELS OVER 25"S.F. IN AREA,IS EMBEDDED HORIZONTALLY IN THE MORTAR JOINTS BETWEEN EVERY OTHER COURSE. PANEL REINFORCING IS FORMED OF TWO PARALLEL WIRES, EITHER 1" O.C. (FOR USE WITH "THINLINE" SERIES GLS. BILK.) OR 2" O.C. (FOR USE W/ "PREMIERE" SERIES GLS. BILK.), W/ BUTT WELDED CROSSWIRES AT REGULAR INTERVALS. 4' AND 10' LENGTHS AVAILABLE. PC PANEL ANCHORS (MIDDLE): ARE USED TO TIE PITTSBURGH CORNING GLASS BLOCK PANELS INTO THE SURROUNDING FRAMEWORK WHEN CHANNELS ARE NOT USED. FORMED FROM 20 GAUGE PERFORATED - THEN GALVANIZED STEEL STRIPS, PANEL ANCHORS ARE AVAIL. IN 1[" WIDTHS X 24" LENGTHS. EXPANSION STRIPS (BOTTOM): MADE OF WHITE POLYETHYLENE, ARE INSERTED AT THE HEAD AND THE STRIPS REPLACE MORTAR AT THESE POINTS TO CUSHION THE GLASS BLOCK AND ALLOW THE PANEL TO EXPAND & CONTRACT FREELY. FOR METAL CHANNEL OR MASONRY CHASE CONSTRUCTION, PC EXPANSION STRIPS ARE AVAILABLE " THICK X 4" WIDE X 24" LONG. FOR PANEL ANCHOR CONSTRUCTION, STD. 4" WIDE STRIPS ARE EASILY CUT TO 3" WIDTH, FOR 31" "PREMIERE" SERIES BLK., AND TO 21" WIDTH, FOR 32 "THINLINE" SERIES BLOCK. GLASS BDETAILS IMPORTANT: I 15# FELT DRAINAGE PLANE IT IS THE RESPONSIBILITY OF THE OWNER OR BUILDER TO SELECT PRODUCTS IN COMPLIANCE WITH WOOD BASED EXTERIOR SHEATHING- OSB APPLICABLE LAWS AND BUILDING CODES. DO NOT USE MURIATIC ACID ON HOMES AFTER INSTALLING THIS WINDOW. THE ACID MAY DESTROY THE COIL SPRING BALANCE SYSTEM. WINDOWS WILL NOT BE UNDER 718" NOMINAL STUCCO THICKNESS WARRANTY IF EXPOSED TO MURIATIC ACID. DO NOT LAY WINDOWS FLAT OR STORE IN SUN BEFORE INSTALLING. ALL WARRANTIES NULL AND VOID IF ANY VERTICAL HOLES ARE PUT INTO WINDOW SILL AREA OF ANY WINDOW. PAPERBACK LATH PEEL AND STICK TAPE METAL OR PLASTIC EXPANSION JOINT DRAINAGE PLANE OVERLAP CONTROL BEAD FLASHING AND MEMBRANE STRIP OVER WOOD FRAME / MASONRY CONNECTION. MEMBRANE STRIP COVERING WOOD FRAME INTERSECTION UNDER EXPANSION JOIN EQUAL TO PROTECTO WRAP BT-20XL-9" WIDE. TO EXTEND 2" BELOW THE CMU 112" NOMINAL CEMENTITIOUS FINISH SCALE: N.T.S. 1 2 WINDOW FLASHING DETAILS ';('Al F- „r1 sZ0STUCCO BOND BREAK/FLASHING SCALE: 3" = 1'-0° DETAIL CHIMNEY HEIGHT 24" ABOVE ROOF WITHIN 10' PRE -FAB CAP OVER CHIMNEY 1/2" PLYWOOD EXT'R. SHEATHING ALL AROUND NAILED 8d @ 6 & 12 2x4 BLOCKING TRUSS @ 24" O.C. FIRE BLOCKING METAL FIRE BLOCKING AROUND FLUE LINER - MANTLE PRE -FAB FIRE BOX DAMPER 18" NON-COMBUSTABLE MATERIAL FOR HEARTH @ 24" O.C. CDPL/R TYP. 7/8" STUCCO OVER PAPER BACK WIRE MESH U.N.O. GALV. L -FLASHING 2x4 BLOCKING 2x4 BLOCKING 2x4 #2 SPF OR #3 SYP STUDS @16" O.C. FOUNDATION ROOF UNDERLAYMENT PER FBC R905.2.7 CDX PLYWOOD OR O.B.S. LATH AND STUCCO "J" METAL FLASHING 4x5 BASE FLASHING ROOF COVERING PER PLAN 15/32" C.D.X. OR 7/16" O.S.B. (MIN. 2.5:12 PITCH) ROOF UNDERLAYMENT PER �FFBC 2x's @ 24" O.C. W/ HUGHES Nf ATTACHED TO SHEATHING WHEN GREATER THAN 24" x 24". C C) r' �v .•• •.• p;Z O o; = U 6 W cc O:Z= Zv) 4(<0 _ — . �� •.••• X68 .....•. 0�� ��• a. a V_ to Go fill fNI 4.4 = a aU. o� U c 00 w= n �99 J U- 74� INSTALLATION NOTES: 1. THROUGHOUT INSTALLATION, KEEP THE WINDOW JAMBS PLUMB AND SQUARE. KEEP HEAD AND SILL LEVEL AND SQUARE. MAKE SURE HEAD AND SILL ARE NOT CROWNED UP OR DOWN. 2. CONSTANTLY CHECK WIDTH AT MEETING RAILS (i.e. DOUBLE HUNGS) TO AVOID "BOWED OUT' INSTALLATION. 3. APPLY GENEROUS BEAD OF CAULK ALONG INTERIOR SURFACE OF NAILING FIN ON ALL SIDES PRIOR TO SETTING WINDOW INTO OPENING. 4. PLACE 1/4" SHIMS AT SILL CORNERS AND SET WINDOW INTO SHIMS. CENTER THE WINDOW IN THE OPENING ALLOWING A 1/4" GAP BETWEEN WINDOW AND FRAMING MATERIAL ON EACH SIDE. WHEN INSTALLATION IS COMPLETE, THESE SHIMS MAY BE REMOVED. 5. INSTALL FASTENERS (STRAIGHT, NOT ANGLED) IN EVERY OTHER FASTENER SLOT STARTING AT THE MIDDLE OF THE WINDOW. FASTENER MUST BE EMBEDDED INTO SOLID WOOD A MINIMUM OF 111. KEEP WINDOW LOCKED UNTIL ALL SIDES ARE SECURED. 6. CAULK OVER FASTENERS AND ANY FASTENER SLOTS NOT USED. 7. CAULK OUTSIDE PERIMETER OF INSTALLED WINDOW. 8. INSULATE AROUND PERIMETER WITH BATT TYPE INSULATION. DO NOT USE EXPANDABLE FOAM. THE USE OF EXPANDABLE FOAM WILL VOID WARRANTY. 9. FOR ANY INSTALLATION FINISHED WITH BRICK OR STONE, ALLOW 1/4" GAP AT SILL BETWEEN STRUCTURE AND WINDOW. THEN, CAULK THIS GAP. 10. CAULK GAP BETWEEN INSTALLED WINDOW EXTERIOR PERIMETER AND J -CHANNEL (OR BRICK OR OTHER EXTERIOR FINISHING MATERIAL WHICH SURROUNDS WINDOW). FLASHING SEQUENCING: • APPLY BOTTOM PIECE OF SELF-ADHESIVE TYPE FLASHING OVER ALL OF ROUGH OPENING. • SET WINDOW UNIT. • APPLY 2ND BOTTOM PIECE OF SELF-ADHESIVE TYPE FLASHING OVER NAILING FIN AND BLDG PAPER. • APPLY SIDE STRIPS OF SELF-ADHESIVE TYPE FLASHING. • APPLY TOP PIECE OF SELF-ADHESIVE TYPE FLASHING. NOTE: SELF-ADHESIVE TYPE FLASHING IS A GENERIC TERM. SEE SPECIFICATIONS FOR MATERIAL TO BE USED. CONCRETI HEADER 0 LINTEL PC EXP. S7 PC ANCHC STRIP GLS. BLK. PC PANEL REINFOR. SEALANT PC ANCHC I" EXP. BOI PER ANCH MORTAR ASPHALT EMULSION CONIC. BL( WALL EXTERIOR PANEL ANCHOR CONSTRUCTION PC PANEL REINFORCING (TOP): USED IN PANELS OVER 25"S.F. IN AREA,IS EMBEDDED HORIZONTALLY IN THE MORTAR JOINTS BETWEEN EVERY OTHER COURSE. PANEL REINFORCING IS FORMED OF TWO PARALLEL WIRES, EITHER 1" O.C. (FOR USE WITH "THINLINE" SERIES GLS. BILK.) OR 2" O.C. (FOR USE W/ "PREMIERE" SERIES GLS. BILK.), W/ BUTT WELDED CROSSWIRES AT REGULAR INTERVALS. 4' AND 10' LENGTHS AVAILABLE. PC PANEL ANCHORS (MIDDLE): ARE USED TO TIE PITTSBURGH CORNING GLASS BLOCK PANELS INTO THE SURROUNDING FRAMEWORK WHEN CHANNELS ARE NOT USED. FORMED FROM 20 GAUGE PERFORATED - THEN GALVANIZED STEEL STRIPS, PANEL ANCHORS ARE AVAIL. IN 1[" WIDTHS X 24" LENGTHS. EXPANSION STRIPS (BOTTOM): MADE OF WHITE POLYETHYLENE, ARE INSERTED AT THE HEAD AND THE STRIPS REPLACE MORTAR AT THESE POINTS TO CUSHION THE GLASS BLOCK AND ALLOW THE PANEL TO EXPAND & CONTRACT FREELY. FOR METAL CHANNEL OR MASONRY CHASE CONSTRUCTION, PC EXPANSION STRIPS ARE AVAILABLE " THICK X 4" WIDE X 24" LONG. FOR PANEL ANCHOR CONSTRUCTION, STD. 4" WIDE STRIPS ARE EASILY CUT TO 3" WIDTH, FOR 31" "PREMIERE" SERIES BLK., AND TO 21" WIDTH, FOR 32 "THINLINE" SERIES BLOCK. GLASS BDETAILS IMPORTANT: I 15# FELT DRAINAGE PLANE IT IS THE RESPONSIBILITY OF THE OWNER OR BUILDER TO SELECT PRODUCTS IN COMPLIANCE WITH WOOD BASED EXTERIOR SHEATHING- OSB APPLICABLE LAWS AND BUILDING CODES. DO NOT USE MURIATIC ACID ON HOMES AFTER INSTALLING THIS WINDOW. THE ACID MAY DESTROY THE COIL SPRING BALANCE SYSTEM. WINDOWS WILL NOT BE UNDER 718" NOMINAL STUCCO THICKNESS WARRANTY IF EXPOSED TO MURIATIC ACID. DO NOT LAY WINDOWS FLAT OR STORE IN SUN BEFORE INSTALLING. ALL WARRANTIES NULL AND VOID IF ANY VERTICAL HOLES ARE PUT INTO WINDOW SILL AREA OF ANY WINDOW. PAPERBACK LATH PEEL AND STICK TAPE METAL OR PLASTIC EXPANSION JOINT DRAINAGE PLANE OVERLAP CONTROL BEAD FLASHING AND MEMBRANE STRIP OVER WOOD FRAME / MASONRY CONNECTION. MEMBRANE STRIP COVERING WOOD FRAME INTERSECTION UNDER EXPANSION JOIN EQUAL TO PROTECTO WRAP BT-20XL-9" WIDE. TO EXTEND 2" BELOW THE CMU 112" NOMINAL CEMENTITIOUS FINISH SCALE: N.T.S. 1 2 WINDOW FLASHING DETAILS ';('Al F- „r1 sZ0STUCCO BOND BREAK/FLASHING SCALE: 3" = 1'-0° DETAIL CHIMNEY HEIGHT 24" ABOVE ROOF WITHIN 10' PRE -FAB CAP OVER CHIMNEY 1/2" PLYWOOD EXT'R. SHEATHING ALL AROUND NAILED 8d @ 6 & 12 2x4 BLOCKING TRUSS @ 24" O.C. FIRE BLOCKING METAL FIRE BLOCKING AROUND FLUE LINER - MANTLE PRE -FAB FIRE BOX DAMPER 18" NON-COMBUSTABLE MATERIAL FOR HEARTH @ 24" O.C. CDPL/R TYP. 7/8" STUCCO OVER PAPER BACK WIRE MESH U.N.O. GALV. L -FLASHING 2x4 BLOCKING 2x4 BLOCKING 2x4 #2 SPF OR #3 SYP STUDS @16" O.C. FOUNDATION ROOF UNDERLAYMENT PER FBC R905.2.7 CDX PLYWOOD OR O.B.S. LATH AND STUCCO "J" METAL FLASHING 4x5 BASE FLASHING ROOF COVERING PER PLAN 15/32" C.D.X. OR 7/16" O.S.B. (MIN. 2.5:12 PITCH) ROOF UNDERLAYMENT PER �FFBC 2x's @ 24" O.C. W/ HUGHES Nf ATTACHED TO SHEATHING WHEN GREATER THAN 24" x 24". C 0 rn W W Q r a VA C) r' �v .•• •.• p;Z O o; = U 6 W cc O:Z= Zv) 4(<0 _ — . �� •.••• X68 .....•. 0�� ��• a. a V_ to Go fill fNI 4.4 = a aU. o� U c 00 0 rn W W Q r a VA C) r' it r d- C) CD f'-- E a - CV Ch M o� U c 00 w= n N J U- cn C z mcn w' 0 (.0 u- wo N ti 'fn 0 o � � 1 W 0 CU z Q 'L Co 1CD CV N(D04CD UN � 0O (n fu oa N z a Li CU^ M � m O o w- o� } O ,T E W p E ,... Lo cu O N W w Q 00 Q .0 m cu LL Z � ZZ N w z wQ �go L = 0 Lu Ln N E d ROOF COVERING PER o .c 0 o . ROOF UNDERLAYMENT - 0 w � PER FBC R905.2.7 O U 0 rn W W Q r a VA ,.� I (FLASHING DETAIL r m w w _ U) w 0 0 _ Ln w Q 0 Y Q ID 0 N H _ C7 of r 0 d 0 w O it 0 0 N vi � M o� a 00 w= n o j rT"� mcn w' 0 o� u- wo N 0 o °- Z :li 1 1 W 0 LnZ G Q L 0 N UN � o� fu oa N z 01 az M � c� Il� O w- o� V� a _� a -X X ww O N W W = � H .N a ZZ �z wQ o� L 0 Lu Ln O 0- ROOF COVERING PER o PLAN o ROOF UNDERLAYMENT - 0 PER FBC R905.2.7 Q ,.� I (FLASHING DETAIL r m w w _ U) w 0 0 _ Ln w Q 0 Y Q ID 0 N H _ C7 of r 0 d ISSUE DATE I 06/06/2 I (1) O it 0 N � O � M a n E M L 0 O " u- wo L cM 1 m G cn L N � co fu UN N Ln 01 C ISSUE DATE I 06/06/2 I O 0 N }' o � o V) cn Y N � 00 fu UN Ln 0- C M � Il� O V) O O .N a L Lu Ln O 0- 018 PROJECT: 18-0313 SCALE: AS NOTED DRAWN BY: JML & JFT DESIGNED BY: MJS DETAILS D 1 GENERAL NOTES FOUNDATIONS SOIL UNDER SLABS AND UNDER FOOTINGS TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM D1557 (MODIFIED PROCTOR) MINIMUM BEARING CAPACITY 2000 PSF TERMITE TREATMENT REFER TO SECTION R318 PROTECTION AGAINST TERMITES, OF THE FLORIDA BUILDING CODE - RESIDENTIAL CURRENT EDITION, FOR FULL LIST OF REQUIREMENTS CAST IN PLACE CONCRETE 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI, A SLUMP OF 4" PLUS OR MINUS 1", AND HAVE 2 TO 4% AIR ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.58. 2. ALL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 60 MIN. 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 FOR 6x6xW1.4xW1.4 WWF SHALL BE LAPPED AT LEAST 6" & CONTAIN AT LEAST ONE CROSS WIRE WITHIN THE 6".FIBERMIX OF EQUAL SPECIFICATIONS MAY BE USED IN LIEU OF WWF. 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS," ACI 301. 5. HORIZONTAL FOOTING BARS SHALL BE BENT MIN. 12 BAR DIAMETERS (EXCLUDING BEND) AROUND CORNERS OR CORNER BARS WITH MIN.:30' LAP EXCLUDING BEND AT EACH END SHALL BE PROVIDED. 6. MINIMUM LAP SPLICES ON ALL REINFORCING BARS SHALL BE 48 BAR DIAMETERS. 7. SLAB ON GRADE, REINFORCEMENT SHALL BE SUPPORTED IN PLACE FROM THE CENTER TO UPPER 1/3 OF THE SLAB. BOLTS AND THREADED RODS 1. ALL BOLTS & THREADED RODS TO BE ASTM A307 OR BETTER (U.N.O.) 2. STEEL BOLTS LESS THAN ONE -HALF-INCH (12.7 mm) IN DIAMETER USED AS FASTENERS FOR PRESSURE PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. 3. FASTENERS OTHER THAN NAILS AND TIMBER RIVETS SHALL BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC -COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55, MINIMUM. MASONRY WALL CONSTRUCTION 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, W/ A MINIMUM NET COMPRESSIVE STRENGTH OF 2000 PSI (fm = 1900 PSI) 2. MORTAR SHALL BE TYPE M OR S, CONFORMING TO ASTM C270 3. HEAD MORTAR JOINTS AT PRECAST WINDOW SILLS TO BE NO MORE THAN 1". 4. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. 5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS FILLED WITH COARSE GROUT AND GRADE 60 STEEL. REINFORCEMENT SHALL BE PLACED IN CENTER OF MASONRY CELL W/ MIN 1/2" CLEARANCE TO INSIDE FACE. 6. VERTICAL REINFORCEMENT SHALL BE HELD IN CENTER OF THE MASONRY/ BLOCK WALL AT THE TOP & BOTTOM & MAXIMUM 8'-0" U.N.O. VERTICALLY. TIES TO THE FOOTING & LINTEL STEEL IS ADEQUATE @ TOP & BOTTOM OF WALL; REBAR POSITIONERS IN MIDDLE OF WALL 7. REINFORCING STEEL SHALL BE LAPPED MIN. 30"U.N.O. 8. HOOKS AT THE TOP & BOTTOM OF VERTICAL REINFORCING BARS TO BOND COURSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND 9. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED ANCHORS OR EPDXY FASTENED STUDS SHALL BE USED. 10. MASONRY ROUGH OPENING TOLERANCES - 1/4" TO + 1/2" 11. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF GROUT INTO CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. 12. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 13. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318, LATEST EDITION. 14. DURING CONCRETE POURS, GC TO ADEQUATELY VIBRATE THE FILLED CELL W/ EITHER RODDING OR PENCIL VIBRATOR TO ENSURE PROPER CONCRETE CONSOLIDATION. WOOD CONSTRUCTION 1. WOOD CONSTRUCTION SHALL CONFORM TO THE ANSI/AWC "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", LATEST EDITION.(NDS) 2. LUMBER DENOTED AS SPF#2 OR SPF#1/#2 SHALL BE SPRUCE -PINE -FIR VISUALLY GRADED "No.1/No.2" BY NLGA, OR BETTER. 3. LUMBER DENOTED AS SYP#2 SHALL BE SOUTHERN YELLOW PINE OR "MIXED" SOUTHERN YELLOW PINE VISUALLY GRADED "No 2" BY SFIB, OR BETTER. 4. OTHER LUMBER SHALL BE VISUALLY GRADED "No. 2" OR BETTER, REGARDLESS OF SPECIES, U.N.O. ON FRAMING PLANS OR DETAILS. 5. ALL STRUCTURAL WOOD MEMBERS INCLUDING EXTERIOR FRAME WALLS, BEARING WALLS, SHEAR WALLS, AND MISC. MEMEBERS (I.E. BLOCKING OR GABLE END BRACING) SHALL BE SPF#2 OR BETTER U.N.O.. 6. END -JOINTED LUMBER IS NOT PERMITTED TO BE USED IN ANY LOAD BEARING (GRAVITY OR WIND) CONDITIONS. E.O.R. TO REVIEW IF INSTALLED. 7. FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. 8. THE PORTIONS OF GLUED -LAMINATED TIMBERS THAT FORM THE STRUCTURAL SUPPORTS OF A BUILDING OR OTHER STRUCTURE AND ARE EXPOSED TO WEATHER AND NOT PROPERLY PROTECTED BY A ROOF, EAVE OR SIMILAR COVERING SHALL BE PRESSURE TREATED WITH PRESERVATIVE, OR BE MANUFACTURED FROM NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD. 9. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE ONLY (MOISTURE CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHERS. 10. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION SHIELDS. ALL HOLES OVER 1" IN DIA FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH SIMPSON HSS2 STUD SHOES, TYP U.N.O. 11. MANY OF THE PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE BUILDER'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE. ACQ-C, ACQ-D, CBA -A OR CA -B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOR SODIUM BORATE (SBX) DOES NOT. 12. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH, CONCRETE OR MASONRY IS TO BE PRESSURE TREATED IN ACCORDANCE WITH THE LATEST EDITION OF THE AWPA U1 STANDARD. 13. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 14. SEE PLAN FOR BUILT UP STUD COLUMN AND BEAM NAILING PATTERNS ENGINEERED LUMBER 1. ENGINEERED LUMBER PRODUCTS SHALL CONFORM TO THE CURRENT EDITION OF THE ANSI/AWC NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS). 2. ENGINEERED LUMBER SHALL BE EITHER STRUCTURAL COMPOSITE LUMBER AS DEFINED NDS SECTION 8.1 (INCLUDING LVL, PSL, AND LSL LUMBER) 3. ALL ENGINEERED LUMBER IS TO HAVE THE MINIMUM DESIGN VALUES AS FOLLOWS: COLUMNS BEAMS STUD E = 1,700,000 Wine U.N.O. E = 2,000,000 Wine U.N.O. E = 1,500,000 Wine U.N.O. Fb =2650 Fb =3000 Fb =2200 Ft = 1650 Ft = 1700 Ft = 1500 Fc 11= 3000 Fc 11= 3000 Fc 11= 2100 Fc j = 450 Fc j = 900 Fc j = 450 Fv = 285 Fv = 285 Fv = 150 WOOD BEARING SURFACES ARE TO BE SYP#2 OR BETTER END GRAIN CONDITION U.N.O. CEILING CONSTRUCTION 1. USE 1/2" CEILING OR SAG RESISTANT BOARD FOR 24" O.C. FRAMING U.N.O. 2. 5/8" TYPE "X" GYPSUM BOARD SHALL BE USED ON CEILING IN GARAGE WHEN LIVING SPACE IS ABOVE THE GARAGE. MEANS AND METHODS CONSTRUCTION MEANS & METHODS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURE IS UNSTABLE UNTIL ALL LOAD BEARING WALLS ARE ERECTED & TRUSS / FRAME MEMBERS ARE CONNECTED PROPERLY PER APPROVED FRAMING PLANS / DETAILS ALONG W/ CONNECTOR & COMPONENT MANUFACTURERS' SPECIFICATIONS. UNTIL SUCH TIME, TEMPORARY BRACING & SHORING OF WALLS AND FRAME MEMBERS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. UNDER STAIR PROTECTION 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 -INCH (12.7MM) GYPSUM BOARD. METAL COATINGS FOR USE WITH PRESSURE TREATED WOOD IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT ALL METAL CONNECTORS, METAL FASTENERS, ANCHORS, AND NAILS ARE THE APPROPRIATE MATERIAL AND/OR HAVE THE APPROPRIATE COATING FOR USE WITH THE DIFFERENT TYPES OF PRESSURE TREATED WOODS, AS PER THE FOLLOWING GUIDELINES. 1. WOOD TREATED WITH DOT SODIUM BORATE(SBX): CONNECTORS SHALL BE A MINIMUM G50 ZINC COATING 2. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE (NON -DOT) TREATMENTS: CONNECTORS SHALL BE A MINIMUM G185 ZINC COATING. 3. FOR ALL OTHER COMBINATIONS FOLLOW THE RECOMMENDATIONS OF THE PRESERVATIVE WOOD TREATER. 4. STAINLESS STEEL CONNECTORS AND FASTENERS MAYBE USED WITH ALL TYPES OF PRESSURE TREATED WOOD SUCH THAT THEY MEET THE REQUIREMENTS OF ASTM F1667 PREFABRICATED WOOD TRUSSES 1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS.UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR LATERAL FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE COORDINATE WITH THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS AND STRUCTURAL PLANS FOR MORE INFO. 2. TRUSSES SHALL BE DESIGNED BY MWFRS METHODOLOGY FOR LONG SPAN TRUSSES TO DETERMINE UPLIFT AND REACTION VALUES. MEMBER AND PLATE DESIGN TO BE CALCULATED BY COMPONENTS AND CLADDING METHOD UNLESS SPECIFIED OTHERWISE BY TRUSS ENGINEER OF RECORD 3. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI TPI 1. 4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQUIRED BY TRUSS MANUFACTURER UNLESS NOTED ON PLANS 5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY TRUSS MANUFACTURER IN ACCORDANCE WITH THE DESIGN LOADS. TRUSS DESIGN LOADS: TOP CHORD: Lr = 16 PSF DL = 7 PSF (SHINGLE TYPE ROOF COVER) DL = 15 PSF (LIGHT WEIGHT CLAY TILE ROOF COVER) DL = 14 PSF (TRUSS OVERBUILD) BOTTOM CHORD: DL = 5 PSF MINIMUM FLOOR DESIGN LIVE LOADS: A) FLOORS = 40 PSF B) BALCONIES =60 PSF / 100 PSF (IF BALCONY > 100 SQ FT) C) DECKS = 40 PSF D) STAIRS = 40 PSF E) BONUS ROOM/GAME ROOMS = 60 PSF U.N.O. MINIMUM FLOOR DESIGN DEAD LOADS: A) FLOORS = 15 PSF B)BALCONIES = 15 PSF GENERAL LOADING: ATTIC WITHOUT STORAGE = 10 PSF ATTIC WITH LIMITED STORAGE = 20 PSF GUARDRAILS / HANDRAILS = 200 LB POINT LOAD / 50 PSF GUARDRAILS IN -FILL COMPONENTS = 50 PSF GENERAL TRUSS BRACING & BLOCKING REQUIREMENTS -ADDIT'L BRACING & BLOCKING PER BCSI-1 & TRUSS MANUFACTURER'S DWGS -G.C. TO PROVIDE MIN 2x SYP #2 BLOCKING BETWEEN TRUSSES TO COMPLY W/ APA RECOMMENDATIONS FOR MIN. 7/16" OSB SHEATHING -MIN 2x SYP #2 BLOCKING REQ'D ALONGSIDE TRUSS TOP CHORD @ ROOF HIP/RIDGE TO PREVENT SHEATHING SPAN FROM EXCEEDING 2FT (NOT REQ'D IF SHEATHING SPAN IS LESS THAN 2FT). BLOCKING TO TRUSS TOP CHORD w/ (2) 12d NAILS @ 12" O.C. MAX & 4" FROM EA. END. NOTE: PLYWOOD EDGES @ HIP CORNERS REQUIRE MIN 2x4 SYP #2 BLOCKING w/ (3) 12d TOENAILS EACH END. -TRUSS "X" BRACING: MIN 2x4 SYP #2 AT ANGLE APPROX. 45° FROM VERT. TO EA. TRUSS MEMBER w/ (3) 12d NAILS. SPACE "X" BRACING ALONG TRUSS SPAN @ 10'-0" MAX AND EQUALLY SPACED FROM END OF TRUSS. "X" BRACING TO START 20'-0" MAX FROM #1 HIP GIRDER AND / OR (4) BAYS AFTER GABLE END BRACING. SEE BCSI-B3 SECTIONS 1, 2 AND 3 FOR ADDITIONAL ROOF PLANE PERMANENT BRACING REQUIREMENTS. -PERMANENT 2x4 SPF #2 (MIN.) CONT. LATERAL TRUSS BOTTOM CHORD BRACING PERPENDICULAR TO TRUSS SPAN AT 15'-0" O.C. MAX W/IN TRUSS SPAN OR PER TRUSS DESIGN DRAWINGS. ATTACH W/ (2) 16d NAILS AT EACH TRUSS. OVERLAP BRACING AT LEAST ONE TRUSS SPACE (24") PLUS 6" MIN PAST BOTTOM CHORD. -INSTALL PERMANENT 2x CONTINUOUS LATERAL BRACE (CLB) ACROSS TRUSS WEBS AS INDICATED ON TRUSS SHOP DRAWINGS & BCSI-133. ("T" BRACING MAY BE USED I.L.O. PEMANENT CLB IF IT EXTENDS MIN. 90% OF THE TRUSS WEB (SEE WEB REINFORCEMENT TABLE WITHIN BCSI-63). -AT RAISED HEEL TRUSSES, 2x4 SYP #2 (MIN.) AT TOP AND BOTTOM OF HEEL W/ (2) 12d TOENAILS REQ'D. EXT. SHEATHING MUST BE ATTACHED TO RAISED HEEL TRUSS AND INDICATED BLOCKING. ALTERNATE IF HEEL HEIGHT IS LESS THAN 12" TALL: 2x4 SYP #2 BEHIND THE TRUSS VERT. RUNNING FROM TOP TO BOTTOM ACROSS MAX 4 TRUSSES, THEN BOTTOM TO TOP W/ (2) 12d NAILS AT EACH TRUSS MEMBER (DIAGONAL BRACING) DIAGONAL BRACING REQUIRED AT CLB PER BCSI-B3. 6. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS, WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. FIELD REPAIR NOTES 1. OMITTED REBAR DRILL A 3/4" 0 HOLE MIN. 6" DEEP AT LOCATION OF OMITTED REBAR, AND INSTALL #5 BAR INTO EPDXY FILLED HOLE. EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQ. FOLLOW MANU'S INSTRUCTIONS. ASSURE ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM HOLE w/ COMPRESSED AIR PRIOR TO APPLYING EPDXY. ALLOW EPDXY TO CURE TO MANU'S SPECIFICATIONS, THEN FILL CELL IN NORMAL WAY DURING BONDBEAM POUR. USE 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN. 12 BAR DIAMETERS(EXCLUDING BEND). 2. STRAPS/CONNECTOR SUBSTITUTION MAY SUB STRAPS/CONNECTORS w/ STRAPS/CONNECTORS OF EQUAL OR GREATER UPLIFT & LATERAL RESISTANCE VALUES IN FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED. 3. STAIR CONSTRUCTION 2X12'S MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS. RIM BOARDS MAY BE USED FOR RISERS & TREADS ILO 2x12'S (SEE GEN. STAIR DETAIL SHEET FOR MORE INFO.) 4. METAL STUD SUBSTITUTION WOOD STUDS MAY BE SUBBED w/ METAL STUDS IN NON -LOAD BEARING WALLS 5. OMITTED J -BOLT -1/2" ALL THREAD ROD w/ 2" x 2" SQ. WASHER DRILL & EPDXY w/ SIMPSON SET EPDXY WITH MIN. 7" EMBEDMENT. -1/2"x6" SIMPSON TITEN HD THREADED ANCHORS W/ LBP1/2 WASHER MAY BE USED ILO 1/2" J -BOLT. TAPCON FASTENERS MAY BE USED ILO SIMPSON TITENS 6. MORTAR JOINTS -FOR BED JOINTS 1/2"-1", GROUT FILL CELLS IN BLOCK AFFECTED (NO VERT. REINF. REQ'D) -FOR HEAD JOINTS GREATER THAN 3/4", GROUT FILL CELL IN BLOCK AFFECTED ON EA.SIDE OF JOINT. PROVIDE (1) #5 VERT. REINF. IN EA. CELL CONT. PER PLAN. "EXCEPTION: IF TIE BEAM COURSE AND ADJ. TWO COURSES BELOW, AS WELL AS 1 st (2) COURSES FROM FND. HAVE HEAD JOINTS WHICH FALL W/IN THE SPECIFIED TOLERANCES, THE ADDED VERTICAL REINFORCEMENT IS NOT REQ'D TO BE EPDXIED INTO TIE BEAM/FTG -FOR BLOCKS NOT STAGGERED, GROUT FILL CELL EA. SIDE OF JOINT AND PROVIDE (1) #5 VERT. REINF. IN EA. CELL, CONT. PER PLAN. 7. OVERHANGING CMU WALL -FOR CMU OVERHANGING FOUNDATION <1/2", NO FIX IS REQ'D POUR TIEBEAM & VERT. CELLS PER PLAN. -FOR CMU OVERHANGING FOUNDATION FROM +1/7-1-1/8", GROUT FILL FIRST (3) COURSES IN WALL ALONG AREA AFFECTED & TIE BEAM AND VERTICAL CELLS PER PLAN -FOR CMU OVERHANGING FOUNDATION OVER 1-1/8", CONTACT EOR FOR REPAIRS. STRUCTURAL STEEL 1. MATERIAL SPECS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 36, Fy=36 KSI. TUBE STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI. PIPE STEEL: ASTM A53, TYPE E OR S, Fy = 35 KSI. ALL OTHER STRUCTURAL & MISC. STEEL: A36 Fy=36 KSI. 2. STRUCT. CONNECTIONS: ALL STRUCT. BOLTS TO BE A325N U.N.O. ALL A325N BOLTS SHALL BE AT "SNUG -TIGHT" CONDITION AS DEFINED IN THE SPEC. SLIP CRITICAL (SC) BOLTS MUST BE FULLY TENSIONED PER SPEC STRUCT. BOLTS SMALLER THAN 5/8" DIA. TO BE A307 THREADED ROD & CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINF.T SHOP DWGS TO BE PROVIDED TO EOR BEFORE FABRICATION FOR REVIEW AND APPROVAL. WELDED CONNECTIONS: ELECTRODES - E70XX UNO (LOW HYDROGEN). FILLET WELDS SHALL BE 3/6' UNO. 3. SUBMIT SHOP DWGS INDICATING ALL SHOP AND ERECTION DETAILS INC. PROFILES, SIZES, SPACING, & LOCATIONS OF STRUCTURAL MEMBERS, CONNECTION ATTACHMENTS, FASTENERS, LOAD, AND TOLERANCES. 4. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE SPRAY -ON FIRE PROTECTION. 5. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND SPECS (IF PROVIDED). SUBMIT REPORTS TO ARCHITECT AND ENGINEER. DESIGN PRESSURES WIND DESIGN LOAD INFORMATION WIND SPEED (ULTIMATE) 140 mph WIND SPEED (ALLOWABLE) 108 mph WIND EXPOSURE B RISK CATEGORY 11 BUILDING TYPE V B ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT +/-0.18 FOUNDATION DETAILS WIND PRESSURE & SUCTION EFFECTIVE (PSF) WIND (+) VALUE DENOTES PRESSURE AREA (SQ FT) - VALUE DENOTES SUCTION AREA ) O5 SD3 (+) 21.2 (+) 21.2 10 - 22.9 (- 28.3 t�w •- Lu LU (+) 20.2 (+) 20.2 20 (-) 22.0 - 26.4 O (+) 19.0 (+) 19.0 50 (-) 20.8 (-) 23.9 100 (+) 18.0 (+) 18.0 �c0�0cr �� Za0�w o - 19.8 - 22.0 GARAGE DOORS 9'-0" x 7'-0" 16-0" x 7'-0" UQQ (+) 1 .4 + Z O ,,c) (-) 20.9 (-) 19.7 WIND PRESSURE/ SUCTION DIAGRAM 50.4 4 Pa STANDARD DESIGN PRESSURE NOTES 1. ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS PER FLORIDA BUILDING CODE 6th EDITION (2017). WIND SPEED IS BASED ON LINEAR INTERPOLATION FOR THIS SITE. 2. MEAN ROOF HEIGHT FOR A TYPICAL SINGLE STORY HOME IS 15FT, 2 STORY HOME IS 30FT 3. MULTIPLY THE ABOVE PRESSURES BY 1.67 TO GET ULTIMATE WIND PRESSURES. 4. "a" = END ZONE IS ONLY W/IN V-0" OF ALL EXTERIOR BUILDING CORNERS. 5. INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREAS. 6. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR GREATER IS CONSIDERED TO BE IN THE WIND -BOURNE DEBRIS REGION. GLAZED OPENING PROTECTION IS REQUIRED AND SHALL BE PROVIDED PER SECTION R301.2.1.2 OF THE FLORIDA BUILDING CODE - RESIDENTIAL, CURRENT EDITION. INDEX OF DRAWINGS SHEET I SHEET TITLE SC STRUCTURAL NOTES sic FOUNDATION PLAN S2C DOWEL PLACEMENT PLAN S3 FOUNDATION DETAILS S3.1 FOUNDATION DETAILS S4C LINTEL PLAN S5C ROOF FRAMING PLAN S6 NOTES & CONNECTOR LEGEND SD1 GENERAL DETAILS SD2 GENERAL DETAILS SD3 GENERAL DETAILS SD4 GENERAL DETAILS NUMBER I DATE i 16� u MASTER UPDATES DESCRIPTION 3/21/2017 I CREATED ELEV A,B,C, A wBONUS, B wBONUS & C wBONUS 8/31/2017 1 CREATED ELEV A,B,C, & A, B,C wBONUS wTRAY OPTION 11/30/20171 CREATED ELEV A wTRAY @ MASTER OPTION PER LOT WP -230 2/3/2018 UPDATED TO MEET FBC 6th EDITION (2017) RESIDENTICAL CODE - ELEV'A' wTRAY @ MASTER OPT. PER WP -75 2/22/2018 1 CREATED ELEV B wTRAY @ MASTER OPTION PER LOT WP -73 J Q z w 0 W w 0 z O im 0o C=0 N I,- 0 W cn Q I NTIALS 0 0 a HG O HG a HG HG JW COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. O 0 91A ♦^ U° ``��I11111111/,� QC CHECK: Nr s�•••o••.• n/.c�I ••• � �--'- CF) M �• lJ rn w 6.0 LU aoo .x co gr) 0 00 •w Y U z ,o • r �•Q= i aD Q 00*Z= G -j O Z J am z n/ LL t�w •- Lu LU V H E J =o f� odJOwtirn 8. I(Dwu)zOM�.°c_ ►Illlllll���j O 0o C=0 N I,- 0 W cn Q I NTIALS 0 0 a HG O HG a HG HG JW COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. O 0 91A U ti 00 H J LLF W>> W 0wW 2 CO) oWcZa O � Q Uma= W � Q O Z � Q O N BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING -DESi�rv: ♦^ U° WM QC CHECK: Nr JOB No. �--'- 88 g ° AS INDICATED O .x Z U z ,o z J am z n/ LL t�w •- Lu LU V H E J =o f� odJOwtirn 8. I(Dwu)zOM�.°c_ Za0JLL� v=i W �v~opo 0 m _ �c0�0cr �� Za0�w o I- �- D= z w z E OzF- wYO W W ''^^ v!wJa UQQ Z O ,,c) W M OO o 2 U ti 00 H J LLF W>> W 0wW 2 CO) oWcZa O � Q Uma= W � Q O Z � Q O N BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING -DESi�rv: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 SC 0 CD 45'-0" SYMBOLS LEGEND ■ INDICATES GROUT FILLED CELL WITH (1) VERT. GRADE 60 #5 CONT. FTG. TO TIE BEAM (8'-0" O.C. MAX U.N.O.) • INDICATES GROUT FILLED CELL WITH (2) VERT. GRADE 60 #5 CONT. FTG. TO TIE BEAM. E1 INDICATES GROUT FILLED CELL WITH NO REINFORCEMENT. t INDICATES 45° CORNER BLOCK GROUT FILLED WITH (2) VERT. GRADE 60 #5 CONT. FT.G TO TIE BEAM. FOUNDATION PLAN 1/4"=11-011 FOUNDATION NOTES: 1. PROVIDE MIN. 6 MIL. APPROVED VAPOR BARRIER. ALL JOINTS TO BE LAPPED MIN. 6" AND SEALED. REFER TO FBC-R CURRENT EDITION SECTION R506.2.3 FOR REQUIRED LOCATIONS 2. PROVIDE 4" 250OPSI CONC. SLAB W/ 6x6xW1.4xW1.4 WELDED WIRE MESH PLACED AT MIDDLE OR UPPER 1/3 OF SLAB DEPTH OVER 6 MIL. VAPOR BARRIER ON COMPACTED FILL (FIBER MESH MAY BE USED ILO WWM, WHEN FIBER MESH. MEETS OR EXCEEDS SPECIFICATIONS SET FORTH IN CURRENT CODE EDITION). 3. VERT. #5 BAR TO BE HOOKED AT TOP & BOTTOM (FTG. & TIE BEAM ENDS) W/MIN. 12 BAR DIAMETER LEGS EXCLUDING BEND @ EA. END. LAP SPLICES SHALL BE NO LESS THAN 30". 4. CONSULT W/MAN. SPECIFICATIONS PRIOR TO POURING OR RECESSING DOOR SILLS. 5. EXTERIOR SLABS SHALL SLOPE 1/8" PER FOOT AWAY FROM HOUSE. 6. CONTROL JOINTS (IF SHOWN) ARE NOT REQUIRED BY CODE BUT ARE SUGGESTED (ESPECIALLY WHEN USING FIBER REINF. CONC.) CONTROL JOINTS TO BE SAW CUT A DEPTH OF 1/4" OF THE THICKNESS OF THE SLAB. FILL CUT W/APPROVED JOINT MATERIAL OR USE ALTERNATE APPROVED METHOD. 7. MECHANICAL EQUIP. LOCATIONS WILL BE DETERMINED BY COMMUNITY & COUNTY CODES. 8. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3" ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 9. NO WOOD STAKES PERMITTED IN FOUNDATION. 10. PENDING SITE CONDITIONS, FOUNDATION MAY HAVE TO BE STEPPED DOWN. SEE SHEET S3 FOR ADDITIONAL INFORMATION. GC TO DETERMINE STEP LOCATIONS IF REQUIRED 11. SEE TYPICAL DETAIL ON LINTEL PLAN FOR REQUIRED STEEL BENDS AND LAP SPLICE. SEE DTL MF09 AND MF10 ON S3 FOR STANDARD FOOTING STEP DOWN AND CORNER INFORMATION. 12. ANY EQUIPMENT AND/OR APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED A MIN OF 18". CONTRACTOR TO PROVIDE SUCH PLATFORM w/ EITHER MASONRY OR WOOD CONSTRUCTION 13. ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF (SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS). IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY, THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. SOIL TO BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS, COMPACTED IN 12" LIFTS TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM - D1557 ( MODIFIED PROCTOR). THE FOUNDATION SIZES INDICATED ON THE FOUNDATION PLAN HAS BEEN DESIGNED FOR A MINIMUM SOIL BEARING CAPACITY OF 2000 PSF. 14. PENDING SITE CONDITIONS, IF STEMWALL IS REQUIRED, G.C. TO DETERMINE REQUIRED COURSES FOR STEMWALL FOUNDATION. SEE STEMWALL CHART ON S3 FOR REQUIRED REINFORCEMENT AND FOOTING SIZES PENDING DEPTH OF STEMWALL. 15. IF STEM WALL IS REQUIRED TO BE CONSTRUCTED TALLER THAN THE HEIGHTS PROVIDED ON THE STEM WALL SCHEDULE ---STOP— CONTACT E.O.R. PRIOR TO CONSTRUCTION 16. ALL FOUNDATION PADS WHERE SHOWN ON THE BELOW FOOTING SCHEDULE SHALL BE INSTALLED WHERE THE DEPTH OF THE FOOTING WILL BE MEASURED FROM THE LOWEST SLAB ELEVATION MAINTAINING A MINIMUM DEPTH AS SPECIFIED. THE FOUNDATION PAD MAY BE INSTALLED DEEPER THAN THE INDICATED PENDING SITE CONDITIONS AND/OR LOCATIONS, CONTRACTOR TO FIELD VERIFY ALL MINIMUM FOUNDATION DIMENSIONS AND REINFORCEMENT REQUIREMENTS ARE MET. FOOTING SCHEDULE 12"x12"x12" dp w/ #5's EQUALLY SPACED EA. 13'-4" WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (2) # 5 E.W. 17'-0" 14'-8" 12"x24"x12" dp w/ #5's EQUALLY SPACED EA. 24" SIDE @3" O.C. & MIN A 8> F01 (3) #5 PARALLEL TO 12" BARS & 3" MIN. COVER TO EDGE OF CONC. SIDE 6" O.C. MF01 24"x24"x12" dp w/ #5's EQUALLY SPACED EA. 2O WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (3) # 5 E.W. S3 BARS & 3" MIN. COVER TO EDGE OF CONC. 28"x28"x12" dp w/ #5's EQUALLY SPACED EA. S3 2.3 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (4) # 5 E.W. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ BARS & 3" MIN. COVER TO EDGE OF CONC. 32"x32"x12" dp w/ #5's EQUALLY SPACED EA. 2.6 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (5) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 36"x36"x12" dp w/ #5's EQUALLY SPACED EA. O WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (5) # 5 E.W. PAVERS 42"x42"x12" dp w/ #5's EQUALLY SPACED EA. 3.5 I MIN (6) # 5 E.W. N I I N 42"x42"x16" dp w/ #5's EQUALLY SPACED EA. I WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (6) # 5 E.W. BARS & 3" MIN, COVER TO EDGE OF CONC. I 48"x48"x12" dp w/ #5's EQUALLY SPACED EA. �_ � I 4O ■ MIN (7) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 48"x48"x16" dp w/ #5's EQUALLY SPACED EA. 4A 2.3 F01 S3 MIN (7) # 5 E.W. I BARS & 3" MIN. COVER TO EDGE OF CONC. .I 4B WAY MIN. 2" HORIZ. CLEARANCE BETWEEN S3 1' BARS & 3" MIN. COVER TO EDGE OF CONC. I. 52"x52"x12" dp w/ #5's EQUALLY SPACED EA. I WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (7) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. I 4.5 ir MIN (8) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. _• F11 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (9) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 60"x60"x16" dp w/#5's EQUALLY SPACED EA. F01 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN IS3 BARS & 3" MIN. COVER TO EDGE OF CONC. i 66"x66"x16" dp w/#5's EQUALLY SPACED EA. 5.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN S3 BARS & 3" MIN. COVER TO EDGE OF CONC. F01 ■ S3 ■ � 0 " I ao IN ■ ■ ■ o ° O I° I I. I o0 I. ■I F03 °O 4" THICK CONC. SLAB W/ I S3 ■ FIBERMESH. OVER 6 MIL VAPOR BARRIER OVER COMPACTED FILL. ■ (- '-3 /2 ■ q Iv AF07 — — — — — — 0 I f I T ---- LO II 1 II I II I I ■ S3 - co I I E10I II I F 7 I ■ ° . X I I LJ 11'-0 " — 7'-10" IMF01 S3 j F06 I _ F06 ao F06 - F03 I ■ I S3 �;, S3 2.3 S3, L S3 ■ ■ I F03 A/C PAD 'I 10'-8" S3 8'-0" F05 MF01 MF01 S3 F11 i i r 1 i S3 I S3 S3 i i lO 1 1 I 11L – _j I O F01 • • 1 i MF01 I I-- (—)0'-4" I S3 1 1 S3 ( I ( ■ (_.� u_' - PAVERS .- 13'-4" 5'-4" 7'4" I o� I bo N N LL U d Co I I ■.I I■I F02 ■S3 F02 J L S3 I 18'-8" 8" 9'-4" 8" bo F 13 � 10'-8" 10'-8" Ilk I 4'-4"7[ S3 • • DO D •!J6 DO D 25'-8" 1'-8" At 16'-0" V-8" 7r 45'-0" SYMBOLS LEGEND ■ INDICATES GROUT FILLED CELL WITH (1) VERT. GRADE 60 #5 CONT. FTG. TO TIE BEAM (8'-0" O.C. MAX U.N.O.) • INDICATES GROUT FILLED CELL WITH (2) VERT. GRADE 60 #5 CONT. FTG. TO TIE BEAM. E1 INDICATES GROUT FILLED CELL WITH NO REINFORCEMENT. t INDICATES 45° CORNER BLOCK GROUT FILLED WITH (2) VERT. GRADE 60 #5 CONT. FT.G TO TIE BEAM. FOUNDATION PLAN 1/4"=11-011 FOUNDATION NOTES: 1. PROVIDE MIN. 6 MIL. APPROVED VAPOR BARRIER. ALL JOINTS TO BE LAPPED MIN. 6" AND SEALED. REFER TO FBC-R CURRENT EDITION SECTION R506.2.3 FOR REQUIRED LOCATIONS 2. PROVIDE 4" 250OPSI CONC. SLAB W/ 6x6xW1.4xW1.4 WELDED WIRE MESH PLACED AT MIDDLE OR UPPER 1/3 OF SLAB DEPTH OVER 6 MIL. VAPOR BARRIER ON COMPACTED FILL (FIBER MESH MAY BE USED ILO WWM, WHEN FIBER MESH. MEETS OR EXCEEDS SPECIFICATIONS SET FORTH IN CURRENT CODE EDITION). 3. VERT. #5 BAR TO BE HOOKED AT TOP & BOTTOM (FTG. & TIE BEAM ENDS) W/MIN. 12 BAR DIAMETER LEGS EXCLUDING BEND @ EA. END. LAP SPLICES SHALL BE NO LESS THAN 30". 4. CONSULT W/MAN. SPECIFICATIONS PRIOR TO POURING OR RECESSING DOOR SILLS. 5. EXTERIOR SLABS SHALL SLOPE 1/8" PER FOOT AWAY FROM HOUSE. 6. CONTROL JOINTS (IF SHOWN) ARE NOT REQUIRED BY CODE BUT ARE SUGGESTED (ESPECIALLY WHEN USING FIBER REINF. CONC.) CONTROL JOINTS TO BE SAW CUT A DEPTH OF 1/4" OF THE THICKNESS OF THE SLAB. FILL CUT W/APPROVED JOINT MATERIAL OR USE ALTERNATE APPROVED METHOD. 7. MECHANICAL EQUIP. LOCATIONS WILL BE DETERMINED BY COMMUNITY & COUNTY CODES. 8. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3" ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 9. NO WOOD STAKES PERMITTED IN FOUNDATION. 10. PENDING SITE CONDITIONS, FOUNDATION MAY HAVE TO BE STEPPED DOWN. SEE SHEET S3 FOR ADDITIONAL INFORMATION. GC TO DETERMINE STEP LOCATIONS IF REQUIRED 11. SEE TYPICAL DETAIL ON LINTEL PLAN FOR REQUIRED STEEL BENDS AND LAP SPLICE. SEE DTL MF09 AND MF10 ON S3 FOR STANDARD FOOTING STEP DOWN AND CORNER INFORMATION. 12. ANY EQUIPMENT AND/OR APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED A MIN OF 18". CONTRACTOR TO PROVIDE SUCH PLATFORM w/ EITHER MASONRY OR WOOD CONSTRUCTION 13. ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF (SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS). IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY, THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. SOIL TO BE FREE OF ORGANIC MATERIAL AND COHESIVE SOILS, COMPACTED IN 12" LIFTS TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM - D1557 ( MODIFIED PROCTOR). THE FOUNDATION SIZES INDICATED ON THE FOUNDATION PLAN HAS BEEN DESIGNED FOR A MINIMUM SOIL BEARING CAPACITY OF 2000 PSF. 14. PENDING SITE CONDITIONS, IF STEMWALL IS REQUIRED, G.C. TO DETERMINE REQUIRED COURSES FOR STEMWALL FOUNDATION. SEE STEMWALL CHART ON S3 FOR REQUIRED REINFORCEMENT AND FOOTING SIZES PENDING DEPTH OF STEMWALL. 15. IF STEM WALL IS REQUIRED TO BE CONSTRUCTED TALLER THAN THE HEIGHTS PROVIDED ON THE STEM WALL SCHEDULE ---STOP— CONTACT E.O.R. PRIOR TO CONSTRUCTION 16. ALL FOUNDATION PADS WHERE SHOWN ON THE BELOW FOOTING SCHEDULE SHALL BE INSTALLED WHERE THE DEPTH OF THE FOOTING WILL BE MEASURED FROM THE LOWEST SLAB ELEVATION MAINTAINING A MINIMUM DEPTH AS SPECIFIED. THE FOUNDATION PAD MAY BE INSTALLED DEEPER THAN THE INDICATED PENDING SITE CONDITIONS AND/OR LOCATIONS, CONTRACTOR TO FIELD VERIFY ALL MINIMUM FOUNDATION DIMENSIONS AND REINFORCEMENT REQUIREMENTS ARE MET. FOOTING SCHEDULE COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. J Q z w O U w r; O w 0� 0.` E�C U WA Ir O J U_ w H U_ O U z O O a w H 0 J Q H U w J a O U z Q w H a i U LL O U z O O a w H U U co LL O z 0 Q U O J w x F– w U z 0 O U U Q z 0 w co O a - z z O J z w 2 H 0 z U x O 0 w z Fo O w 0 Cl) w Ir U U) J Q t— z w 0 F5 w Ir 1- z O CL U LU 0 m z 0 0 J z I— 0 LU LL LU W U 00 (q Q W W > > LLJ Owe Q LLI w�a 3 CYW Ma O Z aaN M LLI M a oo W o J Z = U Q J w OO m 0 N U ° o � ° z U� z °0 m z ti U) w W U ti w H 06 _j . .4- `- U rn cnZ -N� �wz0c')�.c ZQO JU-i w 0 (=U wOQ c OZF-wY0 UQMw�a w< Z3:OLo M 0o O C BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 1 sic 12"x12"x12" dp w/ #5's EQUALLY SPACED EA. O WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (2) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 12"x24"x12" dp w/ #5's EQUALLY SPACED EA. 24" SIDE @3" O.C. & MIN A 8> WAY MIN. 2" HORIZ. CLEARANCE BETWEEN (3) #5 PARALLEL TO 12" BARS & 3" MIN. COVER TO EDGE OF CONC. SIDE 6" O.C. 24"x24"x12" dp w/ #5's EQUALLY SPACED EA. 2O WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (3) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 28"x28"x12" dp w/ #5's EQUALLY SPACED EA. 2.3 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (4) # 5 E.W. BARS & 3" MIN, COVER TO EDGE OF CONC. 30"x30"x12" dp w/ #5's EQUALLY SPACED EA. 2.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (4) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 32"x32"x12" dp w/ #5's EQUALLY SPACED EA. 2.6 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (5) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 36"x36"x12" dp w/ #5's EQUALLY SPACED EA. O WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (5) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 42"x42"x12" dp w/ #5's EQUALLY SPACED EA. 3.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (6) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 42"x42"x16" dp w/ #5's EQUALLY SPACED EA. WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (6) # 5 E.W. BARS & 3" MIN, COVER TO EDGE OF CONC. 48"x48"x12" dp w/ #5's EQUALLY SPACED EA. 4O WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (7) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 48"x48"x16" dp w/ #5's EQUALLY SPACED EA. 4A WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (7) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 48"x48"x24" dp w/ #5's EQUALLY SPACED EA. 4B WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (8) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 52"x52"x12" dp w/ #5's EQUALLY SPACED EA. 4.3 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (7) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 54"x54"x16" dp w/#5's EQUALLY SPACED EA. 4.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (8) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 54"x54"x24" dp w/#5's EQUALLY SPACED EA. WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (9) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 60"x60"x16" dp w/#5's EQUALLY SPACED EA. O WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (9) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. 66"x66"x16" dp w/#5's EQUALLY SPACED EA. 5.5 WAY MIN. 2" HORIZ. CLEARANCE BETWEEN MIN (10) # 5 E.W. BARS & 3" MIN. COVER TO EDGE OF CONC. COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. J Q z w O U w r; O w 0� 0.` E�C U WA Ir O J U_ w H U_ O U z O O a w H 0 J Q H U w J a O U z Q w H a i U LL O U z O O a w H U U co LL O z 0 Q U O J w x F– w U z 0 O U U Q z 0 w co O a - z z O J z w 2 H 0 z U x O 0 w z Fo O w 0 Cl) w Ir U U) J Q t— z w 0 F5 w Ir 1- z O CL U LU 0 m z 0 0 J z I— 0 LU LL LU W U 00 (q Q W W > > LLJ Owe Q LLI w�a 3 CYW Ma O Z aaN M LLI M a oo W o J Z = U Q J w OO m 0 N U ° o � ° z U� z °0 m z ti U) w W U ti w H 06 _j . .4- `- U rn cnZ -N� �wz0c')�.c ZQO JU-i w 0 (=U wOQ c OZF-wY0 UQMw�a w< Z3:OLo M 0o O C BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 1 sic 0 v -v 0 -v N 6 v A I Co M 4'-8" 3'-10" 4'-10" 17'-0" V-4" 3'-8" 4'-8" 3'-8" 1'-4" V-8" 16'-0" 11'-8" SYMBOLS LEGEND ■ INDICATES GROUT FILLED CELL WITH (1) VERT. GRADE 60 #5 CONT. FTG. TO TIE BEAM (8'-0" O.C. MAX U.N.O.) • INDICATES GROUT FILLED CELL WITH (2) VERT. GRADE 60 #5 CONT. FTG. TO TIE BEAM. 0 INDICATES GROUT FILLED CELL WITH NO REINFORCEMENT INDICATES 45° CORNER BLOCK GROUT FILLED WITH (2) VERT GRADE 60 #5 CONT. FT.G TO TIE BEAM. FILLED CE - (1) #5 HORIZONTAL TIE AT TOP, BOTTOM AND AT 24"o.c. VERTICALLY BETWEEN COLUMN AND MAIN HOUSE CMU (1) CONT. #5 FROM TIE BEAM TO FOOTING (1) #5 HORIZONTAL TIE AT TOP, 10 BOTTOM AND E] AT 24"o.c. VERTICALLY BETWEEN COLUMN AND —F7L MAIN HOUSE CMU PLAN VIEW C A SECTION VIEW TYPICAL MASONRY COLUMN TIE IN LAP SPLICE MIN. OF 25" 3/4" = 1'-0" DOWEL PLACEMENT PLAN 1/4"=11-011 COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. z O F- 0 - U W 0 --- -STRUCT: U 0 QC CHECK: CC JOB No. PSQ-0205409 SCALE: z DATE: '� 6 2v� .•`�, o 0 W o • LU i� Q� ►w -J IIz= �. Q Z U u O 4( < J .• •• ���� ui d i1 •••••• `�� Z WUtiw_ �VmH E J0��� O LL _I O J W c9WZo��.= Z -' ZQOJwm z O F- 0 - U W 0 00 H—j CO) Q W 0 LLI W OWW Q W IXoa � (j) W �p O � Qo�a cL N BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN. --- -STRUCT: U 0 QC CHECK: CC JOB No. PSQ-0205409 SCALE: z DATE: '� 6 W o V W1L-' `7 0 --SIL („) f I z az U)W .I< ^ WUtiw_ �VmH E J0��� O LL _I J W c9WZo��.= Z -' ZQOJwm W W N I -5p: C (—ZQO3 Q� ccaa w O o=zwzE OQ=wxo W LU 0 <oga a� Z�O�, v/ M 0 L o O G C 00 H—j CO) Q W 0 LLI W OWW Q W IXoa � (j) W �p O � Qo�a cL N BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN. --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 S2C (1) #5 FROM FTG. TO BOND BEAM IN FULLY alb. 0 GROUTED CELL. (1) #5 FROM FTG. TO 8" C.M.U. FINISH PER SPLICE TO BE MIN. 30" MIN 5" (2) #5 BARS @ TOP MASONRY WALL � CURB WHEN MONO DEPTH MASONRY WALL �I1. EXCEEDS 26". IF SEE PLAN SPLICE TO BE MIN. 30" DEPTH IS LESS THAN CONCRETE SLAB PER CONCRETE SLAB PER a a 26", THESE BARS ARE FOUNDATION PLAN° ..Ila NOT REQUIRED #3 STIRRUPS @ `l l EXCEEDS 26". IF ° 48" O.C. WHEN a °' ° ' ° ° .°- - •' - 4' a' MONO DEPTH ° ` l :.. ' ° Co FOUNDATION PLAN ° NOT REQUIRED EXCEEDS 26", IF --_ I a , .11" ° 114. GRADE Z DEPTH IS LESS — I I— ° SEE PLAN < _ Z > d° THAN 26" A Co g FOUNDATION #3 STIRRUPS @ 1 ° GRADE z ' d' 48 O.C. WHEN_— I (— ' . P —_ THESE BARS (FRONT VIEW) I — MONO DEPTH d I ° •�I III 00 d tea• 7 ° _ d 'd° ° .. MAX 6" DIA. EXCEEDS 26", IF ' — .. . g I °a `' M I III 1811- ARE NOT REQ'D a0 DEPTH IS LESS ao _� =I I .. .e�l ° I (- b .. I—I THAN 26" I IIII THESE BARS = —_ _ (2) #5 BARS CONT. III= CONT... BY TIE IN OR EPDXY ARE NOT REQ'D I I W/ 3" COVER TYP. CLEAN . • CLEAN COMPACTED 8" V-4" FILL @ 95% STANDARD W/ 3" COVER TYP. 8" V-4" DENSITY DENSITY ALL REINFORCEMENT SHALL -1 1 1 111-1'-4" 11 MAINTAIN 3" CLEAR TO DENSITY ALL REINFORCEMENT SHALL 3" COVER TYP. GRADE AND 1-1/2" CLEAR TO MAINTAIN 3" CLEAR TO WHERE 2ND STORY OCCURS, FTG WHERE 2ND STORY OCCURS, FTG O.C. WHEN MONO ANY FACE EXPOSED TO SHALL BE 1'4" WIDE W/(3) #5 BARS DEPTH EXCEEDS 26", SHALL BE V-4" WIDE W/(3) #5 BARS ANY FACE EXPOSED TO WEATHER 1 W/ 3" COVER TYP. WEATHER FO TYPICAL EXTERIOR FOOTING 3/4"=1'-0" 2x BRG WALL PER PLAN AND BEARING WALL SCHEDULE CLEAN COMPACTED 2x P.T. BASE PLATE FILL @ 95% STANDARD DENSITY CONC. SLAB PER FOUNDATION PLAN _ ° •.a: Z -ISI=IIS II�� I=��Ilil�ll=1 - III—III�III _ I I I (2) #5 BARS CONT. W/ $ I' 8,. 3" COVER TYP. 8" 8 WHERE 2ND STORY OCCURS, FTG SHALL BE V-8" WIDE W/(3) #5 BARS FOOTING AT INTERIOR BEARING NOTE: AT FRENCH DOOR LOCATIONS. CONTRACTOR TO VERIFY WITH DOOR MANUF. FOR REQUIRED RECESS THRESHOLD PER - MANUFACTURER'S SPECIFICATIONS 3/4"=1'-0" U) U) W U w M �— SLOPE THRESHOLD PER MFR'S. SPECIFICATIONS EXTEND SLAB OUT 1 1/2" AT FRONT ENTRY DOOR & GARAGE ENTRY SWING DOOR U) CONC. SLAB PER LIJ U) FOUNDATION PLAN W SLOPE A• PER DOOR MANUFACTURER SLOPE EXT. SURFACE OR GRADE 1/8" PER FOOT AWAY FROM BUILDING 1/2" FIBER EXPANSION AS REQUIRED F1 EXTERIOR DOOR POURED SILL (1) #5 FROM FTG. TO TIE BEAM SPLICE TO BE MIN. 30" GROUT CELL SOLID SEE PLAN FOR SHOWER SIZE 1 ALL FOUNDATION REINFORCEMENT SHALL MAINTAIN 3" CLEAR TO GRADE AND ALL OTHERS TO MAINTAIN 1-1/2" CLEAR TO ANY FACE EXPOSED TO WEATHER 1 VERIFY W/ DETAILS FOR REQ'D 0 (1) #5 FROM FTG. TO 8" C.M.U. FINISH PER 7" EMBEDMENT BELOW MIN 5" BOND BEAM IN FULLY MASONRY WALL � CURB OPTIONAL CURB BY GROUTED CELL. ° SEE PLAN a FINISH FLOOR SPLICE TO BE MIN. 30" (2) #5 BARS @ TOP 1 TOP COURSE TO BE CONCRETE SLAB PER a a ° ' WHEN MONO DEPTH M CONC. SLAB PER L71U `Y' `l l EXCEEDS 26". IF ° FOUNDATION PLAN EE n DEPTH IS LESS THAN 4' a' CONCRETE SLAB PER > I 26", THESE BARS ARE ° 00 FOUNDATION PLAN ° NOT REQUIRED ..: e...:.: ... ;.: e'' #5 LOOP TIE (TYP.) M w VARIES 90 -DEGREE #5 HOOK °.:, . •: ° I VERIFY PLAN DETAILS SEE PLAN < BARS AT CORNER, OR > d° FOR CONT. A Co g FOUNDATION #3 STIRRUPS @ 1 ° GRADE z ' d' 48 O.C. WHEN_— I (— ' . P —_ (FRONT VIEW) I — MONO DEPTH d I ° •�I III 00 d tea• 7 ° _ d 'd° ° .. MAX 6" DIA. EXCEEDS 26", IF ' — .. . g I °a `' M I III 1811- 16 1 DEPTH IS LESS ao _� =I I .. .e�l ° I (- b .. I—I THAN 26" I IIII THESE BARS = —_ _ (1) BAR CONT. BY TIE IN OR EPDXY ARE NOT REQ'D I I I=I I 1=I I I CLEAN COMPACTED W/ 3" COVER TYP. 3" (2) #5 BARS CONT. FILL @ 95% STANDARD CONNECTION CLEAN COMPACTED W/ 3" COVER TYP. 8" V-4" DENSITY I I ' BEND EACH CONT. #5 FILL @ 95% STANDARD -1 1 1 111-1'-4" 11 CONT. BARS. MAINTAIN DENSITY ALL REINFORCEMENT SHALL 3" COVER TYP. 26", THESE BARS ARE MAINTAIN 3" CLEAR TO WHERE 2ND STORY OCCURS, FTG NOT REQUIRED O.C. WHEN MONO GRADE AND 1-1/2" CLEAR TO SHALL BE 1'4" WIDE W/(3) #5 BARS DEPTH EXCEEDS 26", FOOTING PER MF08 ON ANY FACE EXPOSED TO FO TYPICAL STEP FOOTING DETAIL 1 W/ 3" COVER TYP. WEATHER THIS SHEET BEYOND AFO TYPICAL GARAGE CURB FOOTING AFO NON-BEARING SLAB STEP DOWN 3/4"=1'-0" 3/4"=1'-0" (1) #5 FROM FTG. TO TIE BEAM SPLICE TO BE MIN. 30" GROUT CELL SOLID SEE PLAN FOR SHOWER SIZE 1 ALL FOUNDATION REINFORCEMENT SHALL MAINTAIN 3" CLEAR TO GRADE AND ALL OTHERS TO MAINTAIN 1-1/2" CLEAR TO ANY FACE EXPOSED TO WEATHER 1 VERIFY W/ DETAILS FOR REQ'D 0 ANCHOR TO HAVE MIN. 8" C.M.U. FINISH PER 7" EMBEDMENT BELOW MIN 5" ELEV. e• ••• e CURB OPTIONAL CURB BY : (1) #5 CONT. W/ 1-1/2" a FINISH FLOOR z BUILDER TOP COURSE TO BE CONCRETE SLAB PER a a ° ' >� PENETRATING PIPE CONC. SLAB PER CHAIR BLOCKS. V '����s���r♦i�rnn �o���`` ° I �e TM4 �tl .e . .� ° in FOUNDATION PLAN MAX. 4" 4' a' i 00 ° 00 GRADE C' FOR QUANTITY ..: e...:.: ... ;.: e'' #5 LOOP TIE (TYP.) M �: .;r, + . �; ' :• . REFER TO 90 -DEGREE #5 HOOK °.:, . •: ° I VERIFY PLAN DETAILS ��I—III�I BARS AT CORNER, OR �.�����J a' . ' , . . ° a FOR CONT. °° g FOUNDATION �. �"'� ` INFORMATION CONT. BARS. MAINTAIN FOOTING PER PLAN (FRONT VIEW) PVC E PER DETAIL MD08 ON d tea• 7 ° _ d 'd° ° .. MAX 6" DIA. LINTEL PLAN CONTACT EOR FOR ADDITIONAL REVIEW TO TIE INTO EXT. FTG. (2) #5 BARS @ TOP ° a 16" MIN.L4 ~QO��W BY TIE IN OR EPDXY 0 O Zo=zWz .° �° WHEN MONO DEPTH CONNECTION i VERIFY PLAN DETAILS III—I 11=1 11=1 I I ' BEND EACH CONT. #5 EXCEEDS -1 1 1 111-1'-4" 11 CONT. BARS. MAINTAIN DEPTH IS ESS THAN OR INSTALL #5 HOOK 3" COVER TYP. 26", THESE BARS ARE #3 STIRRUPS @ 48" O W o O NOT REQUIRED O.C. WHEN MONO C DETAIL MD08 ON DEPTH EXCEEDS 26", FOOTING PER MF08 ON (2) #5 BARS CONT. FO TYPICAL STEP FOOTING DETAIL 1 W/ 3" COVER TYP. IF DEPTH IS LESS THAN 26" THESE BARS ARE NOT REQ'D FO FOOTING @ SHOWER AT MASONRY 0 GARAGE --J TOP VIEW @ CORNER CONC. SLAB PER FOUNDATION PLAN / 3/4"=1'-0" FILLED CELL PER PLAN GARAGE WALL BEYOND DRIVEWAY BY BUILDER- CONCRETE OR PAVERS III _ III—I I f` CLEAN COMPACTED FILL @ 95% STANDARD III _I I =1 I I III DENSITY 4" 8" 8" x 8" THICKENED EDGE W/ (1) #5 CONT. W/ 3" COVER, TYP. THICKENED EDGE @ GARAGE DOOR CONC. SLAB PER 8"x12" THICKENED FOUNDATION PLAN SLAB W/ (1) #5 CONT. W/ 3" COVER TYP. 0 -_= = - � I I -_ -_ -III-ISI-ISI ISI III ° •III -I I I- -III -III '—III, II I II I II I II F: I8., II 18I'lI I I I II I II I CLEAN COMPACTED FILL @ 95% STANDARD DENSITY THICKENED EDGE PIPE PARALLEL TO FND 4)1 TYPICAL FOUNDATION PENETRATIONS IF BEARING WALL VERIFY W/ DETAILS FOR REQ'D 3/4"=1'-0" ANCHOR TO HAVE MIN. 8" C.M.U. FINISH PER 7" EMBEDMENT BELOW MIN 5" ELEV. e• ••• e CURB °a ° : (1) #5 CONT. W/ 1-1/2" a FINISH FLOOR z i ao z° �,� Z TOP COURSE TO BE CONCRETE SLAB PER a a ° ' >� PENETRATING PIPE g CHAIR BLOCKS. V '����s���r♦i�rnn �o���`` ° I �e TM4 �tl .e . .� ° in REINFORCEMENT SEE MAX. 4" 4' �^ i 00 ° d °d —I III-� �- FILLED SOLID FOR QUANTITY ..: e...:.: ... ;.: e'' #5 LOOP TIE (TYP.) M �: .;r, + . �; ' :• . REFER TO 90 -DEGREE #5 HOOK °.:, . •: ° I VERIFY PLAN DETAILS FOUNDATION PLAN BARS AT CORNER, OR �.�����J a' . ' , . . ° a FOR CONT. LO g FOUNDATION �. �"'� ` INFORMATION CONT. BARS. MAINTAIN FOOTING PER PLAN (FRONT VIEW) PVC E PER DETAIL MD08 ON d tea• 7 ° _ d 'd° ° .. MAX 6" DIA. LINTEL PLAN CONTACT EOR FOR ADDITIONAL REVIEW TO TIE INTO EXT. FTG. FOR ANY PIPE INSTALLED PARALLEL TO FOUNDATIONS ° a PIPE PARALLEL TO FND 4)1 TYPICAL FOUNDATION PENETRATIONS IF BEARING WALL VERIFY W/ DETAILS FOR REQ'D ABOVE - WALL ANCHOR TO HAVE MIN. V ••eeeeees• �fIll i 7" EMBEDMENT BELOW MIN 5" LOWEST STEP OF e• ••• e CURB °a ° : (1) #5 CONT. W/ 1-1/2" a w M COVER TYP. z i ao z° �,� Z TOP COURSE TO BE CONCRETE SLAB PER a a ° ' >� FOUNDATION PLAN #5 CONT. CHAIR BLOCKS. V '����s���r♦i�rnn �o���`` ° I �e TM4 �tl .e . .� ° in REINFORCEMENT SEE 4' �^ i 00 ° d °d —I III-� �- I_I IN (2) #5 BARS CONT. W/ —' 3" COVER TYP. CLEAN COMPACTED FILL @ 95% STANDARD DENSITY WHERE 2ND STORY OCCURS, FTG SHALL BE V-8" WIDE W/(3) #5 BARS FO DOUBLE STEP FOOTING 3/4"=1'-0" NOTE TO CONTRACTOR: ALL REINFORCEMENT SPECIFIED IN PLAN VERIFY W/ DETAILS FOR REQ'D FOUNDATION DETAILS SHALL TIE IN TO STEEL AT 2 STORY LOCATIONS ADJACENT MONO AND/OR STEM WALL FOUNDATIONS AS SPECIFIED THIS DETAIL. z z Sao o U) MIN. 24" BEFORE ANOTHER STEP r'io>Q VERIFY W/ DETAILS FOR REQ'D J STEEL AT 2 STORY LOCATIONS V ••eeeeees• �fIll i e °r l d< e 4° r e• ••• e A. ' °a ° : .; a o Z �Z < W — i ao z° �,� Z TOP COURSE TO BE �� P d °' ��' � ° ' W W W #5 CONT. CHAIR BLOCKS. V '����s���r♦i�rnn �o���`` .1. I �e TM4 �tl .e . .� ° in REINFORCEMENT SEE ENTIRE BASE TO BE dd i FOUNDATION PLAN m ° FILLED SOLID FOR QUANTITY 4 � is e'' ,° �W 90 -DEGREE #5 HOOK ° ° d ° I VERIFY PLAN DETAILS W o BARS AT CORNER, OR �.�����J a' . ' , . . ° a I FOR REQUIRED #5 I VERTICAL @ EA. �. �"'� ` °' CONT. BARS. MAINTAIN CORNER. LAP REBAR °' ° � Q PER DETAIL MD08 ON d tea• 7 ° _ d 'd° ° .. 3"I COVER TYP. LINTEL PLAN z~z> J c QO-jWN TO TIE INTO EXT. FTG. (I -_ ° a 16" MIN.L4 ~QO��W BY TIE IN OR EPDXY 0 O Zo=zWz .° �° 16' MIN. CONNECTION i VERIFY PLAN DETAILS III—I 11=1 11=1 I I ' BEND EACH CONT. #5 FOR REQUIRED #5 BAR AT STEP DOWN, CONT. BARS. MAINTAIN OR INSTALL #5 HOOK 3" COVER TYP. BARS FOR EACH CONT. THICKENED EDGE O W o O BAR. LAP REBAR PER ° C DETAIL MD08 ON FOOTING PER MF08 ON LINTEL PLAN FO TYPICAL STEP FOOTING DETAIL CONC. SLAB PER - FOUNDATION PLAN PVC SLEEVE MAX — 6" DIAMETER 2F _ z co - z L� (2) #5 x 4'-0" BARS 3/4"=1'-0" 8"CMU - FINISH PER ELEV. FINISH FLOOR PENETRATING PIPE. MAX 4" °. =1IIII II d.�. nd. I I FOOTING PER PLAN CLEAN COMPACTED FILL @ 95% STANDARD (SIDE VIEW) DENSITY CENTERED AT PIPE PVC OR SCH40 SLEEVE PENETRATION C• d d d I I—III—I � —III—I' III—III _ III= I I -I I a • a I—I °° REFER TO OUNDAT; III=III —III=III-FOR CON . PLAN III=111 -I I I PLAN FOR III FOUNDATION SIZE & REINF. I INFORMATION PIPE PERPENDICULAR TO FND HOLD BRG WALL BACK SO GYP FINISH IS 2x BRG WALL PER PLAN AND BEARING FLUSH F FOUNDATION BELOW WALL SCHEDULE CONC. SLAB PER FOUNDATION PLAN I WM I j I 2x P.T. BASE PLATE .d d ° d .°.. e. ° d I I I_Q Z- �o 1 =I I JE II I I I II ° —1► I (I I. (2) #5 BARS CONT. W/ 6" 8" 8" 10" 3" COVER TYP. CLEAN COMPACTED FILL @ 95% STANDARD WHERE 2ND STORY OCCURS, FTG DENSITY SHALL BE V-8" WIDE W/(3) #5 BARS "FOBEARING SLAB STEP DOWN 3/4"=1'-0" TYPICAL CORNER BAR DETAIL (TOP VIEW) 3/4"=1'-0" WOOD POST PER PLAN VERIFY W/ DETAILS FOR REQ'D J STEEL AT 2 STORY LOCATIONS V ••eeeeees• �fIll i e °r l d< e 4° e• ••• e A. ' <' CONNECTION co p O: J: e Q W J o Z i ao z° �,� Z TOP COURSE TO BE U 1 W #5 CONT. CHAIR BLOCKS. V '����s���r♦i�rnn �o���`` �e ° REINFORCEMENT SEE ENTIRE BASE TO BE d. I i FOUNDATION PLAN m FILLED SOLID FOR QUANTITY 4 � is e'' �� t 'L SEE ELEVATION 90 -DEGREE #5 HOOK ' 1 'I CMU BASE W/ (1) #5 BARS AT CORNER, OR ° °! ° ° 1� BEND CONTINUOUS #5 VERTICAL @ EA. wL)�W BARS AROUND °' CORNER. SEE PLAN CORNER. LAP REBAR °' ° � Q PER DETAIL MD08 ON d tea• 7 ° _ d 'd° ° .. J LINTEL PLAN TYPICAL CORNER BAR DETAIL (TOP VIEW) 3/4"=1'-0" WOOD POST PER PLAN J V ••eeeeees• �fIll i FOR SIZE AND BASE M e• ••• e r 00 CONNECTION co p O: J: e Q W J o Z i ao z° �,� Z TOP COURSE TO BE U •• • t-. ee•eeeewe••• �( 11 W J 0 CHAIR BLOCKS. V '����s���r♦i�rnn �o���`` ° ENTIRE BASE TO BE off" i oo m FILLED SOLID N z SEE ELEVATION m � > CMU BASE W/ (1) #5 Z 7 O Z CV) Of _ Uj VERTICAL @ EA. wL)�W CORNER. SEE PLAN Q FOR BASE SIZE; BARS J z~z> J c QO-jWN TO TIE INTO EXT. FTG. J ° a J0 > 0 <"'� U)WR ~QO��W BY TIE IN OR EPDXY 0 O Zo=zWz .° �° z CONNECTION i �, I ° I: O _ la— o� THICKENED EDGE O W o O ° C > FOOTING PER MF08 ON �.:a '< 1 w THIS SHEET BEYOND ° w ;° CONC. SLAB OR W PAVERS PER PLAN PITCH ° °.. . ' d a GRAD, ° I I—III-1 SEE FOUNDATION FOR I d. PAD SIZE =I ! °.l d ..< ..a '' CLEAN COMPACTED $ FILL @ 95 STANDARD /o DENSITYI- ' 6Fik FOOTING @ ENTRY MASONRY COLUMN 3/4"=1'-0" ( 3/4"=1'-0" I 3/4"=1'-0" I COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTH CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. Q z W 0 U) W 1 r; 0 11 BIW Cn I r J V ••eeeeees• �fIll i Uj M e• ••• e r 00 I co p O: J: e Q W J o Z i ao z° �,� Z = U •• • t-. ee•eeeewe••• �( 11 W J 0 i V '����s���r♦i�rnn �o���`` ° z off" i oo m 0O° N z 11 BIW Cn I r U t� OO � J W ; .�_. _0_000. .-•-- -- •-- ---- --------------------------- .. _ � ----�--r.._�-.y -• ---------- -- ----- - -- - - - M Ill ..06069° .�Ni •• •co •. 00 •• w co J J Z Q U °U ° •i •° e w 6 .6 ••.°°..6••• 11111111111 LL ce F_ z O F_ w VJ U J ° Aa Q z Z z "L O u, w Uj W J—H E Q 06 O��o, U UwzoMr ZI—Z> a0— QO- Lw UJI J Z m _jo�c>-b 0 f- F— D U)WR0<sc ZQo�:Mw o O a m z w Z E OwQW_ja Lu �' 2 H O Lo � Oo U) Z c) 0 G U� 00 p J W > > W M 0 w W _uj w Q W w 0 a U = w< w p O Z 0.N _ BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 S3m1 THE GROUT IS LEVEL WITH TOP OF BLOCK FOR PROPER TRUSS/ FLOOR SYSTEM BEARING (MIN 3") AT CORNERS PRECAST "U" PROVIDE GRADE 60 LINTEL W/ 3000 STANDARD #5 LENGTH psi CONC. PER HOOK BAR. LAP LENGTH LINTEL PLAN. IF OTHER BARS INTO °• . REBAR IS -SHEAR WALL T OPENING CORNER AS REQ'D TYPI INDICATED IN SEGMENT 10'-0" 292 5671454 1366/1277 2423/1770 4006/2263 #3 LINTEL, #5 TO BE �. 7 15 HOOKED INTO 41/4 d d SIDE VERTICALS ' 21/2 . °e a .4e 0 n 3 '. 121/2. 32 #5 31/8 7 113/4 25 4 .• .p n 151/21 40 y d. .d ° ZBOTTOM STEEL IN LINTEL IF INDICATE - HOOK INTO VERTICAL CELLS PER MD08 LIe. ROUGH OPENING PER PLAN ° .a.l° METAL LATH OR WIRE SCREEN OVER COURSES NOT REQ'D TO BE FILLED. (SHEET METAL & PAPER FELT PROHIBITED) HOOK PER MD08 °°I ie n -A ° °(: a O ° J ° 0 W g LL w d•. N0IX ( d °.II:°• zMciO W (0 w Q°( ° e° Via._ .. 7.a TYPICAL TRUSS ANCHOR PER PLAN PROVIDE SCREEN WHEN BLOCK BELOW IS NOT REQUIRED TO BE FILLED STANDARD 90 DEGREE HOOK TYP. BOND BEAM 8" x 8" x 16" K.O. LINTEL BLOCK FILL W/ 3000 psi CONC. W/ (1) #5 DIA. REBAR �— STD. 90 DEGREE ANGLE 3000 psi t la CONC. W/ (1) #5 DIA. REBAR TYPICAL MASONRY CONSTRUCTION SEE PLAN FOR TOP OF WALL AND LINTEL INFO 3/4"=1'-0" MAX 4'-0" LINTEL W/ TRANSOM DETAIL 314"=1'-0" SEE DOWEL LAYOUT PLAN FOR FILLED CELL INFORMATION. MIN. (1) IS REQUIRED ON EITHER SIDE OF OPENING U.N.O. (2) 2x8 SYP #2 P.T. WOOD HEADER TURNED SIDEWAYS. ATTACH (2) 2x8 SYP #2 P.T. HEADER TO MASONRY WALL W/ SIMPSON HU28-2 OR HUC28-2 HANGER @ EA. END. USING (14) 1/4" DIA. x 2 3/4" TAPCONS & (6) 1 Od NAILS INTO HEADER. NAIL EACH PLY AND EACH ADDITIONAL HEADER PLY W/ (2) ROWS OF 10d NAILS STAGGERED @ 6" O.C. AND MIN. 2" FROM ENDS. REFER TO DESIGN PLANS FOR REQUIRED IN -FILL FRAMING DIMENSIONS REQ'D LAP SPLICE, EMBEDMENT, AND HOOKED REINF. STEEL (INCHES) °• GRADE 40 GRADE 60 BAR SIZE e LENGTH LAP SPLICE BEND 0 LENGTH LAP SPLICE 3'-4" 1006 1663/1349 5365/1999 7342/3123 10000/4249 °• . NON -SHEAR WALL T OPENING "D" TYPI AL SHEAR WALL SEGMENT 10'-0" 292 5671454 1366/1277 2423/1770 4006/2263 #3 17/8 �. 7 15 e 41/4 d d #4 21/2 5 5/8 91/2 0 n 3 55/8 121/2. 32 #5 31/8 TYPICAL MASONRY CONSTRUCTION SEE PLAN FOR TOP OF WALL AND LINTEL INFO 3/4"=1'-0" MAX 4'-0" LINTEL W/ TRANSOM DETAIL 314"=1'-0" SEE DOWEL LAYOUT PLAN FOR FILLED CELL INFORMATION. MIN. (1) IS REQUIRED ON EITHER SIDE OF OPENING U.N.O. (2) 2x8 SYP #2 P.T. WOOD HEADER TURNED SIDEWAYS. ATTACH (2) 2x8 SYP #2 P.T. HEADER TO MASONRY WALL W/ SIMPSON HU28-2 OR HUC28-2 HANGER @ EA. END. USING (14) 1/4" DIA. x 2 3/4" TAPCONS & (6) 1 Od NAILS INTO HEADER. NAIL EACH PLY AND EACH ADDITIONAL HEADER PLY W/ (2) ROWS OF 10d NAILS STAGGERED @ 6" O.C. AND MIN. 2" FROM ENDS. REFER TO DESIGN PLANS FOR REQUIRED IN -FILL FRAMING DIMENSIONS REQ'D LAP SPLICE, EMBEDMENT, AND HOOKED REINF. STEEL (INCHES) GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE -CRETE, QUALITY, LOTTS, & POWERS STEEL GRADE 40 GRADE 60 BAR SIZE e LENGTH LAP SPLICE BEND 0 LENGTH LAP SPLICE 3'-4" 1006 1663/1349 5365/1999 7342/3123 10000/4249 °• . NON -SHEAR WALL T OPENING "D" TYPI AL SHEAR WALL SEGMENT 10'-0" 292 5671454 1366/1277 2423/1770 4006/2263 #3 17/8 41/4 7 15 n 41/4 91/4 d #4 TYPICAL MASONRY CONSTRUCTION SEE PLAN FOR TOP OF WALL AND LINTEL INFO 3/4"=1'-0" MAX 4'-0" LINTEL W/ TRANSOM DETAIL 314"=1'-0" SEE DOWEL LAYOUT PLAN FOR FILLED CELL INFORMATION. MIN. (1) IS REQUIRED ON EITHER SIDE OF OPENING U.N.O. (2) 2x8 SYP #2 P.T. WOOD HEADER TURNED SIDEWAYS. ATTACH (2) 2x8 SYP #2 P.T. HEADER TO MASONRY WALL W/ SIMPSON HU28-2 OR HUC28-2 HANGER @ EA. END. USING (14) 1/4" DIA. x 2 3/4" TAPCONS & (6) 1 Od NAILS INTO HEADER. NAIL EACH PLY AND EACH ADDITIONAL HEADER PLY W/ (2) ROWS OF 10d NAILS STAGGERED @ 6" O.C. AND MIN. 2" FROM ENDS. REFER TO DESIGN PLANS FOR REQUIRED IN -FILL FRAMING DIMENSIONS REQ'D LAP SPLICE, EMBEDMENT, AND HOOKED REINF. STEEL (INCHES) GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE -CRETE, QUALITY, LOTTS, & POWERS STEEL GRADE 40 GRADE 60 BAR SIZE BEND 0 LENGTH LAP SPLICE BEND 0 LENGTH LAP SPLICE 3'-4" 1006 1663/1349 5365/1999 7342/3123 10000/4249 4'-0" 860 1651/1349 5365/1999 7342/3123 10000/4249 4'-6" 710 1423 / 1105 4360 / 1631 6036 / 2549 8328 / 3470 "C" "D" "A" "B" "C" 10'-0" 292 5671454 1366/1277 2423/1770 4006/2263 #3 17/8 41/4 7 15 21/4 41/4 91/4 24 #4 21/2 5 5/8 91/2 20 3 55/8 121/2. 32 #5 31/8 7 113/4 25 33/4 7 151/21 40 #6 33/4 81/16 14 30 41/2 81/16 181/2 48 #7 43/8 9 13/16 16 1/2 35 51/4 9 13/16 21 3/4 56 LAP SPLICE EMBEDDED REBAR SPLICE DETAIL STANDARD 90° HOOK 3/4"=1'-0" c STANDARD 180° HOOK #3=2%" #4=2Y" #5=2Y2" #6=3" #7 = 3 %" 8" x 8" x 16" CMU U.N.O. INDICATES FILLED CELL FROM FTG. TO TIE BEAM W/ (1) #5 BAR W/ 3000 psi CONC. SEE MD08 FOR LAP INFO. PROVIDE CLEAN OUT OPENING @ GROUT FILLED CELL AND REBAR (TYP). MORTAR JOINTS SHOULD NOT BE CUT SEE FOUNDATION FOR FOOTING PRECAST LINTEL LOAD TABLE LOADS LISTED BELOW HAVE BEEN CALCULATED OR COMPILED FROM DATA FROM THE FOLLOWING APPROVED MAN. CAST -CRETE, QUALITY PRECAST CO., LOTT'S CONCRETE, POWERS STEEL GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE -CRETE, QUALITY, LOTTS, & POWERS STEEL Q z o w r; 0 V zz w = p o w = LL O z 0 O a i F- O J Q w STANDARD LINTEL NOTES STANDARD LINTELS • 'a 1. AREAS OF BLOCK ABV. MASONRY OPENINGS ARE TO BE GROUTED SOLID TO TIE BEAM. 2. (1) #5 REBAR IN TIE BEAM IS TO BE CONTINUOUS THROUGHOUT INCLUDING ABOVE MASONRY OPENINGS. U.N.O. 3. ALL STANDARD LINTELS TO HAVE MIN. 4" NOMINAL BEARING EA. END. ALL RECESSED LINTELS TO HAVE MIN. 8" BEARING EA. END 4. LINTEL MIN. DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF DEEPER LINTEL INSTALLED THAN INDICATED ON PLAN, THE STRENGTH OF THE LINTEL INCREASES AND IS APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT EOR FOR APPROVAL. 5. (*) ANY LINTEL DEEPER THAN 32" HAS BEEN VERIFIED TO WORK AS A MIN. 32" FOR THE LOAD CONDITIONS. ANY LINTEL GREATER THAN 32" HAS A GREATER CAPACITY AND THEREFORE IS ADEQUATE FOR THE LOADS. 6. G.C. TO VERIFY ALL LINTEL DIMS IN FIELD WITH WINDOW R.O. SPECIFICATIONS ON PLAN. DIMS SHOWN ON LINTEL PLAN ARE CLEAR SPAN AND USED TO VERIFY DESIGN OF LINTEL ONLY. VERIFY WITH WINDOW/DOOR SUPPLIER SPECIFICATIONS AND COORDINATE WITH EOR AS REQ'D. 7. LINTELS SHOULD BE SHORED UP DURING CONSTRUCTION AS REQUIRED PER THE LINTEL SUPPLIER SPECS. MCD IS NOT RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS 1'-6" 2231 3069 / 3069 6113 / 6113 8974 / 8974 10000 / 10000 2'-2" 1783 3069/3069 6113/5163 8974/8054 10000/10 2'-8" 1343 2693 / 2561 6113 / 3820 8974 / 5961 10000 / 8107 3'-2" 1217 2165/1969 6113/2931 8672/4576 10000/6224 3'-4" 1006 1663/1349 5365/1999 7342/3123 10000/4249 4'-0" 860 1651/1349 5365/1999 7342/3123 10000/4249 4'-6" 710 1423 / 1105 4360 / 1631 6036 / 2549 8328 / 3470 5'-2" 570 1232/1232 3480/2580 8360/3586 8825/4592 LAP SPLICE EMBEDDED REBAR SPLICE DETAIL STANDARD 90° HOOK 3/4"=1'-0" c STANDARD 180° HOOK #3=2%" #4=2Y" #5=2Y2" #6=3" #7 = 3 %" 8" x 8" x 16" CMU U.N.O. INDICATES FILLED CELL FROM FTG. TO TIE BEAM W/ (1) #5 BAR W/ 3000 psi CONC. SEE MD08 FOR LAP INFO. PROVIDE CLEAN OUT OPENING @ GROUT FILLED CELL AND REBAR (TYP). MORTAR JOINTS SHOULD NOT BE CUT SEE FOUNDATION FOR FOOTING PRECAST LINTEL LOAD TABLE LOADS LISTED BELOW HAVE BEEN CALCULATED OR COMPILED FROM DATA FROM THE FOLLOWING APPROVED MAN. CAST -CRETE, QUALITY PRECAST CO., LOTT'S CONCRETE, POWERS STEEL GENERAL CONCRETE LINTEL SCHEDULE APPROVED LINTEL MANUFACTURERS: CASTE -CRETE, QUALITY, LOTTS, & POWERS STEEL Q z o w r; 0 V zz w = p o w = LL O z 0 O a i F- O J Q w STANDARD LINTEL NOTES STANDARD LINTELS CLEAR OPENING 8" UNFILLED 8F8-1 B / 8F8 -0B 8F16-1 B / 8F16 -OB 8F24 -113/8F24-013 8F32 -113/8F32-013 1. AREAS OF BLOCK ABV. MASONRY OPENINGS ARE TO BE GROUTED SOLID TO TIE BEAM. 2. (1) #5 REBAR IN TIE BEAM IS TO BE CONTINUOUS THROUGHOUT INCLUDING ABOVE MASONRY OPENINGS. U.N.O. 3. ALL STANDARD LINTELS TO HAVE MIN. 4" NOMINAL BEARING EA. END. ALL RECESSED LINTELS TO HAVE MIN. 8" BEARING EA. END 4. LINTEL MIN. DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF DEEPER LINTEL INSTALLED THAN INDICATED ON PLAN, THE STRENGTH OF THE LINTEL INCREASES AND IS APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT EOR FOR APPROVAL. 5. (*) ANY LINTEL DEEPER THAN 32" HAS BEEN VERIFIED TO WORK AS A MIN. 32" FOR THE LOAD CONDITIONS. ANY LINTEL GREATER THAN 32" HAS A GREATER CAPACITY AND THEREFORE IS ADEQUATE FOR THE LOADS. 6. G.C. TO VERIFY ALL LINTEL DIMS IN FIELD WITH WINDOW R.O. SPECIFICATIONS ON PLAN. DIMS SHOWN ON LINTEL PLAN ARE CLEAR SPAN AND USED TO VERIFY DESIGN OF LINTEL ONLY. VERIFY WITH WINDOW/DOOR SUPPLIER SPECIFICATIONS AND COORDINATE WITH EOR AS REQ'D. 7. LINTELS SHOULD BE SHORED UP DURING CONSTRUCTION AS REQUIRED PER THE LINTEL SUPPLIER SPECS. MCD IS NOT RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS 1'-6" 2231 3069 / 3069 6113 / 6113 8974 / 8974 10000 / 10000 2'-2" 1783 3069/3069 6113/5163 8974/8054 10000/10 2'-8" 1343 2693 / 2561 6113 / 3820 8974 / 5961 10000 / 8107 3'-2" 1217 2165/1969 6113/2931 8672/4576 10000/6224 3'-4" 1006 1663/1349 5365/1999 7342/3123 10000/4249 4'-0" 860 1651/1349 5365/1999 7342/3123 10000/4249 4'-6" 710 1423 / 1105 4360 / 1631 6036 / 2549 8328 / 3470 5'-2" 570 1232/1232 3480/2580 8360/3586 8825/4592 6-2" 488 991/991 2661/2143 5681/2698 6472 / 3685 7'-0" 416 752/6991843/1625 3486/2602 6390/3302 8'4" 354 726 / 699 1843 / 1625 3486 / 2255 6205 / 2885 9'-2" 315 618/535 1533/1247 2781/1946 4754/2489 10'-0" 292 5671454 1366/1277 2423/1770 4006/2263 10'-8" 277 492/352 1254/1132 2193/1567 3552/2003 11'-2" 255 471/352 1075/1075 1838/1567 2883/2003 12'-0" 239 418/297 1075/1045 1838/1446 2883/1848 12'-8" 0 369/261 1002/984 1697 / 1361 2630 / 1738 13'-4" 0 328/0 1234/0 1779/0 2662/0 MATERIALS 14'-0" 0 292/0 1160/0 1660/0 2439/0 16'-0" 0 284/0 950/0 1379/0 1997/0 1. fc PRECAST LINTELS = 3500 PSI. 2. f PRESTRESSED LINTELS = 6000 psi. 3. GROUTED PER ASTM C476 fg = 3000 psi W/ MAXIMUM 3/8" AGGREGATE AND 8" TO 11" SLUMP. 4. CONCRETE MASONRY UNITS (CMU) PER ASTM C90 W/ MINIMUM NET AREA COMPRESSIVE STRENGTH = 1900 PSI. 5. REBAR PER ASTM A615 GRADE 60. PRESTRESSING STRAND PER ASTM A416 GRADE 270 LOW RELAXATION. 7/32 WIRE PER ASTM A510. 18'-0" 0 211/0 750/0 1177/0 1676/0 18'-8" 0 142/0 598/0 1114/0 1468/0 20'-0" 0 180 / 0 598 / 0 1024 / 0 1441 / 0 20'-8" 0 1 145/0 1 550/0 981 / 0 1376/0 22'-8" 0 110 / 0 450 / 0 824 / 0 1147 / 0 RECESSED LINTELS -FILLED CLEAR OPENING 8R6-1 B/8R6-OB 8R14-1B/8R14-0I3 8R22-1 B/8R22-OB 21-4" 1694/1694 3725/3280 5499/5421 2'-8" 1425/1425 3343/3280 4933/4933 3'-0" 1230/1230 2769/2769 4085/4085 3'-4" 1081/920 2769/1716 4085 / 2839> 4'-4" 846/833 2121/1716 3127/2839 5'-4" 664/572 1761/1761 2595/2595 64" 526/434 1539/1539 1329/2267 7'-4" 480/322 1334/1334 1964/1552 8'-4" 415 / 235 1152 / 1152 1694 / 1552 1) FOR HEADER DEPTHS DEEPER THAN 32", USE VALUES FOR 32" DEEP HEADER 2) FOR HEADER DEPTHS NOT LISTED ON CHART, USE THE VALUES FOR THE NEXT DEPTH DOWN. 3) POWERS STEEL LINTELS MUST ALWAYS BE FILLED. LINTEL DESIGNATION SCHEDULE MARK LINTEL REQUIREMENTS F =FILLED WITH GROUT U =UNFILLED R = RECESSED & FILLED WITH GROUT OF #5 REBAR @ 8F16-1'B/1T BOTTOM OF LINTEL CAVITY QUANTITY OF #5 REBAR AT TOP NOMINAL HEIGHT TYPE DESIGNATION NOMINAL WIDTH O 8R6-0B/1TQUANTITY 0 8F8-0B/1T Q 8R14-1B/1T O° 8F16-1B/1T 8F40-1B/1T 3'-0" 17'-0�" X-0" 34- 119 Of 10 D ZF Oo in 9'-0" F � r� DO O o Cl) O O� CV O N Oih O M O O CV O NNS O � cn 9'-4" 1114" OOO 11'4"1 O T.O.M. T.O.M. A 8F16-0B/1T rn X-0" V-0" T.O.M. If If N. = 11'-4" T.O.M. IF REFERENCED ON SHEET S4). VERIFY HEIGHT W/ M O 000 J o 101 101 4'8" —1 U 8F24 -16/1T O 8R22-0B/1T DO B 8F24-0B/1T S4C 0 T.O.M. T.O.M. 6'-8" If �o O 16'-0" WALL LEGEND O 8R14-0B/1T O 8F16-0B/1T rn `�.• 8F20-1B/1T 0 = 9'-4" T.O.M. = INTERIOR/EXTERIOR BEARING WALL (OR LINTEL O" 8F20-0B/1T = 11'-4" T.O.M. IF REFERENCED ON SHEET S4). VERIFY HEIGHT W/ M O 000 J o J O 8R22-1B/1T ® = KNEEWALL ARCHITECTURAL PLANS U.N.O.O U 8F24 -16/1T O 8R22-0B/1T Lj O 8F24-0B/1T "O 8R30-1B/1T 0 8F32-1B/1T 0 8R30-0B/1T O 8F32 -OB/1T O 8F38 -1B/1T O 8F12 -1 B/OT O 8F40-1B/1T Ow 8F28 -1B/1T x0 8F40 -0B/1T LINTEL PLAN 7-5/8" ACTUAL 8" NOMINAL WIDTH FILLED 1-1/2" CLEAR #5 REBAR AT TOP MIN. (1) REQ'D C.M.U. GROUT #5 REBAR AT BOTTOM OF LINTEL CAVITY BOTTOM REINFORCING PROVIDED IN LINTEL (VARIES) 1-1/2" CLEAR 7-5/8" ACTUAL 8" NOMINAL WIDTH UNFILLED ui cn 0 W 6z _ =J °.°. =t W _j 0 0 (n W(n <e'. a W W � X � 00 L90mQ z r- IX J aw� z 7-5/8 ACT—UA 8" NOMINAL WIDTH POWERS STEEL fOP MIN. (1) REQ'D BOTTOM REINFORCING PROVIDED IN LINTEL (VARIES) 1-1/2" CLEAR #5 REBAR AT TOP MIN. (1) REQ'D TOP KNOCK OUT/ LINTEL BLOCK COURSE #5 REBAR AT BOTTOM MIN. (1) REQ'D 16 GA. POWERS STEEL BOXED LINTEL SAFE LOAD TABLE NOTES 1. ALL VALUES BASED ON MINIMUM 4" NOMINAL BEARING. EXCEPTION: SAFE LOADS FOR UNFILLED LINTELS MUST BE REDUCED BY 20% IF BEARING LENGTH IS LESS THAN 6-1/2". SAFE LOADS FOR ALL RECESSED LINTELS BASED ON 4" NOMINAL BEARING. 2. 0 = NOT RATED. 3. SAFE LOADS ARE TOTAL SUPERIMPOSED ALLOWABLE LOAD ON THE SECTION SPECIFIED. 4. SAFE LOADS BASED ON GRADE 40, GRADE 60 MAY BE USED WITHOUT WRITTEN APPROVAL FROM EOR 5. ADDITIONAL LATERAL LOAD CAPACITY CAN BE OBTAINED BY THE DESIGNER BY PROVIDING ADDIONAL REINFORCED MASONRY ABOVE THE PRECAST LINTEL. 6. ONE #7 REBAR MAY BE SUBSTITUTED FOR TWO #5 REBARS IN 8" LINTELS ONLY. 7. THE DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE SAFE LOAD TABLES BY CALCULATING THE MAXIMUM RESISTING MOMENT AND SHEAR AT D -AWAY FROM THE FACE OF SUPPORT. 8. FOR COMPOSITE LINTEL HEIGHTS NOT SHOWN, USE SAFE LOAD FROM NEXT LOWER HGT. 9. ALL SAFE LOADS IN UNITS OF POUNDS PER LINEAR FOOT. 1/61=11-011 COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC is strictly prohibited. F- 0 0 U w 0 11' U ° 7 o A° z � d pq 8 z ° z z U 7 � z (D U) W W U W ,� � W D E 06 O cn a, 8 W Z -N a WZOc''>�— ZQO— L_Ljto LU I=��m J F- °_00�w ZQp2w�4 o o2ZwzE z III LU O<Q�JCL za = Z3OLOCV) Oo 0 : 00 � J W >> W 0W W z Q W �Za �0 U CyQ OR � W � Q 0 Z IZ CL N BLDG DESIGN: -- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 S4C i� Lij rn `�.• •. I •ern u.AW: Y o M O 000 J o J z • w '� * I— : zioZ z O•�O� Q U z U C J Lj Q a O li F- 0 0 U w 0 11' U ° 7 o A° z � d pq 8 z ° z z U 7 � z (D U) W W U W ,� � W D E 06 O cn a, 8 W Z -N a WZOc''>�— ZQO— L_Ljto LU I=��m J F- °_00�w ZQp2w�4 o o2ZwzE z III LU O<Q�JCL za = Z3OLOCV) Oo 0 : 00 � J W >> W 0W W z Q W �Za �0 U CyQ OR � W � Q 0 Z IZ CL N BLDG DESIGN: -- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 S4C WALL LEGEND = 9'-4" T.O.M. = INTERIOR/EXTERIOR BEARING WALL (OR LINTEL = 11'4" T.O.M. IF REFERENCED ON SHEET S4). VERIFY HEIGHT W/ ® = KNEEWALL ARCHITECTURAL PLANS U.N.O. ROOF FRAMING PLAN J g z w 0 w ti 0 cltz O 1= M W F - Q 0 z O I— CL U W W 0 U a A pq 8 Z C v � Z U <` z Z. � m Q zi­- OCz �LU L ti U r W r �coti o LL (00 (n -g U O LU Z p cy) ZQOLU �O// 'UO~p>-oa coy LL CAUROQ- c Z<0�:M i o W OUaF-WY0 E W <wLL5 = Z�OL" M 0 L O c O G - U 00 H J W>> W 0 W W i� _ U) Q W LU �o� UUSQ= w p O Z � Qo�� a c•II — BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 NOTE: SEE PAGE S6 FOR NOTES AND CONNECTOR LEGEND 1/4"=11-0" S5C COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. lU���e•0) ``\\\\►Ilrl V_ `j ee••••••�e �1, `� ••. V�tfi C. 00 ••e bei �� W Z iO C') • L - O O i J `.. J 2 �( fw" CC`Q- O1 Z Q J • � z O •� LLI Q D 6 ew•e�• Q Q O� lIF W F - Q 0 z O I— CL U W W 0 U a A pq 8 Z C v � Z U <` z Z. � m Q zi­- OCz �LU L ti U r W r �coti o LL (00 (n -g U O LU Z p cy) ZQOLU �O// 'UO~p>-oa coy LL CAUROQ- c Z<0�:M i o W OUaF-WY0 E W <wLL5 = Z�OL" M 0 L O c O G - U 00 H J W>> W 0 W W i� _ U) Q W LU �o� UUSQ= w p O Z � Qo�� a c•II — BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 NOTE: SEE PAGE S6 FOR NOTES AND CONNECTOR LEGEND 1/4"=11-0" S5C COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. HEADER SCHEDULE BEARING WOOD WALL SCHEDULE TAG HEADER FASTENERS TAG STUD LUMBER CONNECTION & FASTENERS UFT BLOCKING (3)2X4 SPF #2 BUILT UP STUD COLUMN a HETA16 w/(9) 10dx1-1/2" NAILS OR HETA20 w/(9) 10dx1-1/2" NAILS. AT PARALLEL TRUSS CONDITIONS USE LTA2 w/(10) 10dx1-1/12" NAILS 24" O.C. U.N.O. FRAME TO CMU SPACING SPECIES TOP BOTTOM (plf) O H2x6 (2)2x6 #2 SYP w/2' FLITCH PLATE ATTACH KING STUD TO HEADER w/(6) BW1 16 SPF (2)12d (2)12d NO MID -SPAN FRAME TO FRAME H10A 1015 H10A-2 1070 16d NAILS 'till TOENAILS TOENAILS UPLIFT (3)2X6 SPF #2 BUILT UP STUD COLUMN H2x8 (2)2x8 #2 SYP w/2' FLITCH PLATE ATTACH KING STUD TO HEADER w/(8) El HTS20 w/(24)10d x 12" NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME SP4 W/(6) SP4 W/(6) OF (2)2X8 SPF #2 BUILT UP STUD COLUMN (2)HTS20 w/(24)10d x 12" NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) 16d NAILS BW2 16" SPF 10d x 12' NAILS x 10d 12" NAILS 570 plf MID -SPAN H2x10 2)2x10 #2 SYP w/2" FLITCH PLATE ATTACH KING STUD TO HEADER w/(10) (2)2x12 #2 SYP WITH 1/2" FLITCH PLATE TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)4"x24" TAPCONS SP4 W/(6) SP4 W/(6) (3)2X4 SYP #2 BUILT UP STUD COLUMN MTS12 w/(14)10d x 12" NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 16d NAILSBW3 1000 16" SPF 10d x 12 1„ NAILS 1„ 10d x 12 NAILS 570 plf 3rd. PT. 3965 H2x12 2)2x12 #2 SYP w/2" FLITCH PLATE ATTACH KING STUD TO HEADER w/(10) OK (2)2X8 SYP #2 BUILT UP STUD COLUMN 63.5x11. 25 (2)1.75"x11.25" LVL TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS TO MASONRY: SIMP; H�U410 OR HUC410 w/(10)10d NAILS & (18)4 x24 TAPCONS ON MASONRY: (2) SIMP. MSTAM24 a HTT4 w/(1 8)16d x 22" NAILS & 8" EPDXY ANCHOR w/SIMP. SET EPDXY MIN. 7" EMBEDMENT FRAME TO CMU 3640 4235 LO 44 SYP #2 POST NO HGT-2 w/(16)10d NAILS w/ (2) 4" EPDXY ANCHOR w/SIMP. SET EPDXY MIN. 12" EMBEDMENT FRAME TO CMU 10980 16d NAILS BW4 12 SPF (3) 12d TOENAILS (3) 12d TOENAILS UPLIFT MID -SPAN 11 H3.5x5.5 (2)1.75"x5.5" LVL ATTACH KING STUD TO HEADER w/(6) 1175 NO 8x8 SYP #2 POST TO POST: SIMP. HTS20 OR LSTA18 12 LSTA18 w/(14)10d NAILS HEADER TO STUDS 1110 1235 16d NAILS BW5 12" SPF SP4 W/(6) SP4 W/(6) 760 plf MID -SPAN 2220 2470 ATTACH KING STUD TO HEADER w/(8) QO 3-1/2"x5-1/4" LVL COLUMN. 10d x 12" NAILS 10d x 12" NAILS H3.5x7.25 (2)1.75"x7.25" LVL 16d NAILS 14 LSTA18 w/(14)10d NAILS CENTERED EACH STUD BV116 12" SPF SP4 W/(6) SP4 W/(6) 760 plf 3rd. PT. TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & OR 3-1/2"x7" LVL COLUMN. (2)1.75"x9.25" LVL ATTACH KING STUD TO HEADER w/(10) 10d x 12" NAILS 10d x 12" NAILS E H3.5x9.25 STUDS TO BEAM/GT 1235 16d NAILS 63.5x16 (2) 1.75"x16" LVL (10) 10d NAILS TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d <S>3 -1/2"x9-1/2" 3-1/2"x9-1/2" LVL COLUMN. BW7 16" SYP (3) 12d TOENAILS (3) 12d TOENAILS NO UPLIFT MID -SPAN STUDS TO BEAM/GT 2980 ATTACH KING STUD TO HEADER w/(12) H5.5x11.25 (3)1.75"x11.25" LVL 16d NAILS MSTC40 w/ (52)16d SINKERS CENTERED STUDS TO BEAM/GT 4305 4745 TO POST: (2) SIMP. HTS20 OR LSTA18 OV BW8 16" SYP SP4 W/(6) 1„ 10d x 12 NAILS SP4 W/(6) 1„ 10d x 12 NAILS 664 plf MID -SPAN H3x12 (3) 2x12 #2 SYP w/ 2" FLITCH ATTACH KING STUD TO HEADER w/(10) PLATE BETWEEN PLIES 16d NAILS 18 LTT20B w/(10) 10d NAILS & 8" EPDXY ANCHOR w/SIMP. SET EPDXY MIN. 7" EMBEDMENT COLUMN TO FTG.OR CMU 1290 HEADER SUPPORT SCHEDULE BWg 16" SYP SP4 W/(6) SP4 W/(6) 664 plf 1rd. PT. 3 COLUMN TO FTG. 3640 4235 YO 10d x 12" NAILS 10d x 12" NAILS OPENING SIZE SEE PLAN FOR WALL WIDTH JACKS @ EA. END KINGS @ EA. END FRAME TO FRAME 3735 4350 12d (2)12d NO (2) 1.75"x20" LVL TO POST: (2) SIMP. HTS20 OR LSTA18 ON MASONRY: (2) SIMP. MSTAM24 <Z> 5 1/4 X 9 1/2 LVL COLUMN BW10 12" SYP T T TOENAILS UPLIFT MID -SPAN V-0" TO T-11" 1 1 2420 2800 * U.N.O.FASTEN LVL PLIES TOGETHER USING (4) ROWS SOF IIDE/4"X31/2"SDS SCREWS @ 24" O.C. EACH STANDARD COLUMN NOTES BW11 12" SYP SP4 W/(6) 10d x 12" NAILS SP4 W/(6) 10d x 12" NAILS 885 plf MID -SPAN � 4 -0" TO 7 -11 � 2 2 8'-0" TO 9'-11" 2 3 BW12 12" SYP SP4 W/(6) SP4 W/(6) 885 plf 3rd. MGT w/ (22) 10d NAILS TO GIRDER & (1) 5/8" A.T.R. THRU DBL. TOP PLT. TO INVERTED HDU5 ATTACHED TO POST. FRAME TO FRAME 3300 3965 BE P.T. OR WOLMANIZED. 10d x 12" NAILS 10d x 12" NAILS PT. -0 10'-0" TO 12'" 3 4 O.C. (TYP. ONE SIDE) MIN. 2" FROM TOP AND BOTTOM OF BEAM 3. CONTRACTOR TO USE ABU BASE CONNECTORS @ SPF/SYP BW13 16 SPF SP4 W/(6) 10d x 12" NAILS SP4 W/(6) 10d x 12" NAILS 280 plf MID -SPAN STANDARD HEADER NOTES 6x6: ABU66 w/(12)16d NAILS & $" EPDXY ANCHOR w/MIN. 1. ALL TRUSS/BEAM TO MASONRY CONNECTIONS TO BE SIMP. HETA16/20, U.N.O. ON PLAN. 3. VERIFY w/PLAN CORRECT LENGTH OF BEAM REQ'D. (MIN. 4" BRG. EA. END) @ 32"o.c. @ 32"o.c. 4. SEE PLAN FOR TOP OR BOTTOM OF BEAM INDICATIONS. 5. BEAMS ARE NOT TO BE DRILLED OR NOTCHED IN ANY WAY WITHOUT 4. POST/LVL INSTALLED WITHIN BRG. WALL TO BE WITHIN TOPWRITTEN AND BASE PLATE U.N.O. ON PLANS. 1. VERIFY w/PLAN FOR CORRECT LENGTH OF HEADER REQ'D. SIZE INDICATED ON PLAN APPROVAL FROM THE E.O.R. 5. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS. 2. ALL TRUSS/BEAM TO FRAME CONNECTIONS TO BE SIMP. H10A FOR SINGLE PLY, OR H10A-2 SP4 W/(6) SP4 W/(6) FOR 2 -PLY U.N.O. ON PLAN IS MINIMUM REQ'D. PER LOCATION. LARGER HEADER MAY BE INSTALLED WOUT BW14 12" SPF 2 NAILS 10d x 1 1" 1 10d x 1„ 2 NAILS 380 plf MID -SPAN APPROVAL FROM E.O.R. >TANDARD NAIL GENERAL DIAMETER/ LENGTH 4. CONNECT ALL INTERIOR FLOOR TRUSSES/JOISTS TO INTERIOR BRG. WALLS USING (3)12d TOENAILS. 5. ALL TRUSS TO TRUSS CONNECTIONS TO BE SPECIFIED BY TRUSS MANUFACTURER, U.N.O. ON PLAN. @ 24"o.c. @ 24"o.c. 131" x 22" 2. ALL HEADER JACKS/KINGS TO MATCH WALL LUMBER GRADE U.N.O. ON PLAN. 6. MISSED LINTEL STRAPS: CONTRACTOR TO INSTALL SIMP. HTSM16 @ EACH MISSED HETA16/20 10d .148" x 3" STRAP LOCATION. IF DOUBLE HETA16/20 @ A 2 -PLY OR 1 -PLY TRUSS IS MISSED, USE (2)HTSM16 STRAPS. IF UPLIFT IS HIGHER THEN 2100lbs, CONTACT E.O.R. FOR FURTHER REVIEW. ATTACH STUDS TOGETHER 2) STANDARD BEARING WALL W/STRAPS NOTES 3. NAIL #2 SYP HEADER PLIES OGE HIER UDSING ROWS OF 10d NAILS @12" O.C. ONE SIDE. MIN. 2" FROM TOP AND BOTTOM FOR 2X6 AND 2X8 HEADERS. (3) ROWS OF 10d NAILS @12" O.C. ONE SIDE. MIN. 2" FROM TOP AND BOTTOM FOR 2X10 AND 2X12 1. VERIFY w/PLAN FOR WALL SIZE. ASSUME 2x4 STUDS U.N.O. HEADERS. NAILING ABOVE IS FOR TOP -LOADED HEADERS ONLY. CONTACT E.O.R. IF 2. ALL LUMBER TO BE EITHER SPF #2 OR SYP #2 U.N.O. ALWAYS NAIL STUDS TO MEMBERS BUCKET INTO HEADER TOP AND BOTTOM PLATE W/ (3) 12d TOENAILS. 4. NAIL KING STUDS TO HEADER w/(3) 10d TOENAILS PER SIDE IN ADDITION TO NAILING 3. CONNECTORS ARE TO BE INSTALLED @ EA. STUD U.N.O. @ 2x6 STUDS. USE PER HEADER SCHEDULE. SP6 AND @ 2x8 WALLS USE SP8 INSTEAD OF INDICATED SP4. 5. IF MORE THEN (1)KING IS REQ'D. AS PER HEADER SUPPORT TABLE, GC TO INSTALL 4. IF BEARING WALL IS NOT CALLED OUT CONTACT E.O.R. REQ'D. NAILS FROM 1st KING INTO HEADER THEN ATTACH ADDIT'L KING PER DTL. 5. IF "BW" CALLED OUT ON 2nd FLR. SEE PLAN FOR STUD TO STUD CONNECTIONS. WF08/SD3. OTHERWISE, CONTACT E.O.R. FOR REQ'D. WOOD SCREWS, 6. MID OR 3 PT. BLOCKING TO BE 2x W/(2) 12d TOENAILS EACH END. 6. IF HEADER IS NOT SPECIFIED CONTACT E.O.R. 7. BASE PLATE TO BE ATTACHED TO FOOTING USING 2' J -BOLTS OR EPDXY 7. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS. ANCHOR W/ WASHER@ 6" FROM EA. END OF BASE PLATE &WALL OPENINGS & 8. SEE DTL. WF09/SD2 FOR 1ST FLOOR HEADER CONSTRUCTION AND CONNECTIONS AT AT 32" o.c. W/ 7" MIN. EMBEDMENT. USE SIMPSON SET -XP EPDXY W/ EPDXY 2 STORY CONDITIONS. SEE 2ND FLOOR NOTES FOR MORE INFO. ANCHORS. ROOF NOTES. 8. NO ADDITIONAL BASE CONNECTIONS TO THE FOUNDATION ARE REQ'D. IF BRG. WALL IS INDICATED W/BW1, BW4, BW7 OR BW10. THESE WALLS ARE ONLY SUPPORTING THE FLOOR LOAD AND DO NOT HAVE UPLIFT. THE STUDS ARE TO 1. THE ROOF PLAN DEPICTED IS NOT INTENDED TO SERVE AS A TRUSS DESIGN. BE TONAILED/ENDNAILED TO THE PLATES & THE 2x P.T. BASE PLATE CAN BE 2. TOP PLATE HEIGHTS VARY. SEE BUILDING SECTIONS, WALL SECTIONS AND ATTACHED W/HARD CASED GUN NAILS AND WILL NOT REQ. THE ANCHOR BOLT ELEVATIONS FOR BEARING HEIGHTS. ATTACHMENT INDICATED IN THE BEARING WALL NOTES. 3. TRUSS SPACING SHALL BE 24" O.C. MAX. UNLESS OTHERWISE NOTED. 9. FOR BEARING WALL TO MASONRY CONNECTION SEE DETAIL MD03/SD1 U.N.O. CONVENTIONAL FRAMING SHALL BE 16" O.C. MAX. OR AS OTHERWISE NOTED. ON PLAN. 4. FRAME WALLS UP TO UNDERSIDE OF ROOF TRUSSES AT ALL NON-BEARING WALLS 10. AT HEADER LOCATIONS WITHIN BEARING WALLS SEE DETAIL WF09/SD2 U.N.O. AND AT VOLUME AREA UNLESS NOTED OTHERWISE. STUDS CAN BE 24" O.C. W/ ON PLAN. SINGLE TOP AND P.T. BASE PLATE LEAVE 1-1/2" GAP FROM TOP PLATE TO TRUSS 11. COLUMNS WITHIN BEARING WALLS w/UPLIFT THAT DO NOT SHOW A BASE BOTTOM CHORD. CONNECT TRUSS TO NON-BEARING WALL w/ SIMPSON DTC OR (2) CONNECTION: CONTRACTOR TO INSTALL SP4/ SP6/ SP8 AT EACH STUD 12d TOENAILS. TOP/BOTTOM AND HAVE A J -BOLT OR EPDXY ANCHOR WITHIN 6" FROM THE 5. ALIGN TRUSSES AND HAND FRAMING SO ALL GYPSUM WALL BOARD WILL BE COLUMN. 12. IF PLUMBING IS TO BE RUN THROUGH BEARING WALL, CONTACT E.O.R. FOR CONTINUOUS FROM FLOOR TO CEILING. FURTHER REVIEW. 6. TRUSS MANUFACTURER TO INSURE DESIGN CONSIDERATION TO THE FOLLOWING 13. AT NON-BEARING WALL LOCATIONS 2x4 SPF#2 STUDS @ 24"o.c. MAX. ARE ADDITIONAL LOADS: ADEQUATE. AT NON-BEARING HEADERS USE (2)2x4 FLAT w/(3)12d TOENAILS EA. A) ALL CEILING HUNG SOFFITS AND SOFFITS SIDE AND CRIPPLE STUDS AT 24"o.c. AT 2 -STORY OPEN AREAS INSTALL WITH CABINETS AS SHOWN ON PLANS. NON-BEARING WALL STUDS @16"o.c. A SINGLE BASE PLATE (P.T. IF AGAINST B) ATTIC LOCATED HVAC UNITS AS SHOWN ON PLANS. CONCRETE) AND SINGLE TOP PLATE ARE ADEQUATE. LEAVE A 1 1/2" GAP FROM 7. REFER TO MANUFACTURER SPECIFICATIONS FOR INSTALLATION REQUIREMENTS TRUSS TO TOP PLATE AND ATTACH USING SIMPSON DTC CLIP (SEE DETAILS OF ALL HARDWARE BEFORE INSTALLATION. WF20 & WF21/SD2). ATTACH BASE PLATE w/ EITHER GUN NAILS @32"o.c. OR 8. GC REQ'D TO PROVIDE PERMANENT BRACING/ BLOCKING PER BCSI 1 (CURRENT (2)12d NAILS TO EACH FLOOR TRUSS. EDITION). SEE COVER SHEET NOTES FOR MORE INFO & STANDARD DETAILS IN THIS DRAWING SET FOR ADDITIONAL BRACING/ BLOCKING INFO. ROOF & EXT. WALL NAILING SHEATHING NOTE 9. ALL TRUSS -TO -TRUSS CONNECTORS ARE TO BE PROVIDED BY TRUSS SUPPLIER. THIS INCLUDES BUT IS NOT LIMITED TO PIGGY BACK TRUSSES AND VALLEY ROOFS: TRUSSES 10. USE 5/8" TYPE X GYPSUM BOARD ON CEILING IN GARAGE WHEN LIVING SPACE IS ROOF SHEATHING TO BE 7/16" OSB (WITH SHINGLE), 5/8" OR 19/32" OSB (WITH TILE) ABOVE THE GARAGE. FASTENING WITHIN 4'-0" OF EAVES TO BE 4" O.C. AT ALL SUPPORTED EDGES AND 6" 11. IF ROOF TRUSS LAYOUT DEPICTS TRUSS LABELS OR ID'S, THIS LAYOUT HAS BEEN O.C. IN FIELD. FOR ALL OTHER AREAS NAIL @ 6" O.C. AT ALL SUPPORTED EDGES AND PROVIDED BY A TRUSS COMPANY TO USE FOR THE DESIGN OF THIS PROJECT. 6" O.C. IN FIELD. SHEATHING TO BE PLACED WITH LONG DIMENSION PERPENDICULAR OTHERWISE AN ENGINEERED LAYOUT HAS BEEN DETERMINED BUT PRIOR TO TO SUPPORTS (TRUSSES). PROVIDE PLY CLIPS AT ALL UNSUPPORTED ROOF CONSTRUCTION OR TRUSS FABRICATION, FINAL TRUSS LAYOUT AND TRUSS SHOP SHEATHING JOINTS EXCEPT AT PITCH CHANGE LOCATIONS. PLY CLIPS TO BE DRAWS ARE TO BE SUBMITTED TO ENGINEER OF RECORD (E.O.R.) FOR REVIEW SPACED NO MORE THAN 24" O.C. AND APPROVAL. AT THIS TIME THE E.O.R. RESERVES THE RIGHT TO REVISE THE GABLE ENDS: PLAN AS REQUIRED PER THE REVIEW OF THE FINAL TRUSS LAYOUT AND TRUSS ALL SHEATHING TO BE MIN. 15/32" O.S.B. AND SHALL BE NAILED (1) ROW @ 3" O.C. SHOP DRAWS, ADDITIONAL FEE'S MAY APPLY. STARTING CONSTRUCTION OR AT TOP PLATE AND (1) ROW AT BOTTOM PLATE OF WALL, 6" O.C. ALL OTHER TRUSS FABRICATION PRIOR TO THIS REVIEW IS NOT ADVISED, AND THE E.O.R. IS EDGES AND 6" IN FIELD. BLOCKING SHALL BE PLACED AT ALL SHEATHING JOINTS. NOT RESPONSIBLE FOR ADDITIONAL COSTS DUE TO REVISIONS OF THE PLAN. IF CONVENTIONAL FRAMING IS SHOWN, NO TRUSS APPROVAL IS REQUIRED, UNLESS EXTERIOR WALLS: LAYOUT IS REVISED W/OUT WRITTEN APPROVAL FROM MCD. SEE WF10/SD4 FOR MORE INFO. 12. IF DESIGN DOCUMENTS INDICATE THAT AN A/C UNIT IS TO BE RECESSED INTO THE ROOF SYSTEM, THE TRUSS SUPPLIER IS TO COORDINATE WITH THE DESIGNER AND NAILS: BUILDER TO DETERMINE THE REQUIRED SIZE. (2) 751b MIN POINT LOAD SHOULD BE NAILS USED IN ROOF SHEATHING APPLICATIONS SHALL BE 8d RING SHANK NAILS. ADDED TO EITHER THE TOP OF BOTTOM CHORD OF THE TRUSS IN THE AFFECTED ALL OTHER SHEATHING APPLICATIONS SHALL BE 8d, 8d RING OR SPIRAL SHANK, AREAS. THIS LOAD SHOULD BE INDICATED ON THE TRUSS SHOP DRAWINGS. HAND OR GUN DRIVEN NAILS. GUN DRIVEN NAILS SHALL HAVE HEAD SIZE CONNECTIONS OF THE A/C UNIT TO THE TRUSSES SHOULD BE SUPPLIED BY EITHER EQUIVALENT TO HAND DRIVEN NAILS. FASTENERS FOR PRESERV- ATIVELY THE CONTRACTOR OR A/C SUPPLIER. TREATED WOOD SHALL BE HOT -DIPPED ZINC -COATED GALVANIZED STEEL, BUILDER NOTE. STAINLESS STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS SHALL BE IN ACCORDANCE WITH ASTM A 153. IF THE TRUSS LAYOUT SHOWN DOES NOT MATCH THE TRUSS MANUFACTURERS APA SHEATHING NOTE: LAYOUT 24/16 SPAN RATED SHEATHING REQUIRES BLOCKING AT ALL UNSUPPORTED ----STOP---- PANEL EDGES AT HIP LOCATIONS. BLOCKING TO BE 2X4 ATTACHED AT EACH END WITH (3) 10d TOENAILS. AND CALL THE ENGINEER OF RECORD PRIOR TO PLACEMENT OF ANY TRUSSES COLUMN SCHEDULE CONNECTOR SCHEDULE BEAM SCHEDULE <�> (2)2X4 SPF #2 BUILT UP STUD COLUMN TAG SIMPSON CONNECTOR TYPE VALUES SPF(Ib) VALUES SYP(lb) TAG BEAM SIZE CONNECTIONS O (3)2X4 SPF #2 BUILT UP STUD COLUMN a HETA16 w/(9) 10dx1-1/2" NAILS OR HETA20 w/(9) 10dx1-1/2" NAILS. AT PARALLEL TRUSS CONDITIONS USE LTA2 w/(10) 10dx1-1/12" NAILS 24" O.C. U.N.O. FRAME TO CMU 1810 1810 62x„ 8 (2)2x8 #2 SYP WITH 1/2" FLITCH PLATE TO POST: SIMP. HTS20 OR MSTA18 TO BEAM: SIMP. HUC48 w/(14)16d & (6)-10d NAILS TO MASONRY: SIMP. HU48 OR HUC48 w/(6)10d NAILS & (14) 14 x243' TAPCONS ON MASONRY: (1) SIMP. MSTAM24 O (4)2X4 SPF #2 BUILT UP STUD COLUMN F(1)ply (2)HETA16 OR (2)HETA20 TRUSS (10)10d x 12" NAILS TRUSS (12) 16d x 12" NAILS FRAME TO CMU (1)ply 2035 (2)ply 2500 (1)ply 2035 (2)ply 2500 O(2)ply D (2)2X6 SPF #2 BUILT UP STUD COLUMN 3 H10A w/(18)10d x 12" NAILS OR (2)ply TRUSS H10A-2 w/(18) 10d x 1 2' NAILS FRAME TO FRAME H10A 1015 H10A-2 1070 H10A 1340 H10A-2 1245 'till LL OE (3)2X6 SPF #2 BUILT UP STUD COLUMN B2x10 (2)2x10 #2 SYP WITH 1/2" FLITCH PLATE TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)4'x24" TAPCONS ON MASONRY: (1) SIMP. MSTAM24 El HTS20 w/(24)10d x 12" NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 1245 1450 OF (2)2X8 SPF #2 BUILT UP STUD COLUMN (2)HTS20 w/(24)10d x 12" NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 2490 2900 O(3)2X8 SPF #2 BUILT UP STUD COLUMN H2.5A w/(10)8d FRAME TO FRAME 535 600 B2x12 (2)2x12 #2 SYP WITH 1/2" FLITCH PLATE TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)4"x24" TAPCONS HO (3)2X4 SYP #2 BUILT UP STUD COLUMN MTS12 w/(14)10d x 12" NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 860 1000 JO (2)2X6 SYP #2 BUILT UP STUD COLUMN ❑MGT 8 w/(22)10d $" EPDXY ANCHOR w/SIMP. SET -XP EPDXY MIN. 12" EMBEDMENT FRAME TO CMU 3330 3965 ON MASONRY: (2) SIMP. MSTAM24 OK (2)2X8 SYP #2 BUILT UP STUD COLUMN 63.5x11. 25 (2)1.75"x11.25" LVL TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS TO MASONRY: SIMP; H�U410 OR HUC410 w/(10)10d NAILS & (18)4 x24 TAPCONS ON MASONRY: (2) SIMP. MSTAM24 a HTT4 w/(1 8)16d x 22" NAILS & 8" EPDXY ANCHOR w/SIMP. SET EPDXY MIN. 7" EMBEDMENT FRAME TO CMU 3640 4235 LO 44 SYP #2 POST 10 HGT-2 w/(16)10d NAILS w/ (2) 4" EPDXY ANCHOR w/SIMP. SET EPDXY MIN. 12" EMBEDMENT FRAME TO CMU 10980 8910 O 6x6 SYP #2 POST 11 HTSM16 w/(8)10d NAILS & (4) 4"x 24" TAPCONS FRAME TO CMU 1010 1175 NO 8x8 SYP #2 POST TO POST: SIMP. HTS20 OR LSTA18 12 LSTA18 w/(14)10d NAILS HEADER TO STUDS 1110 1235 63.5x11. 875 (2)1.75"x11.875" LVL TO BEAM: SIMP. HUC410 w/(18)16d & (10) 10d NAILS TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d NAILS & (18)4"x24" TAPCONS ON MASONRY: (2) SIMP. MSTAM24 P 3-1/2"x3-1/2" LVL COLUMN. 13 (2)LSTA18 w/(14)10d NAILS HEADER TO STUDS 2220 2470 QO 3-1/2"x5-1/4" LVL COLUMN. 14 LSTA18 w/(14)10d NAILS CENTERED EACH STUD STUDS TO BEAM/GT 833pif 928plf TO POST: SIMP. HTS20 OR LSTA18 TO BEAM: SIMP. HUC410 w/(18)16d & OR 3-1/2"x7" LVL COLUMN. E LSTA24 w/(18)10d NAILS CENTERED EACH STUD STUDS TO BEAM/GT 1235 1235 63.5x16 (2) 1.75"x16" LVL (10) 10d NAILS TO MASONRY: SIMP. HU410 OR HUC410 w/(10)10d <S>3 -1/2"x9-1/2" 3-1/2"x9-1/2" LVL COLUMN. NAILS & (-!" 18)4 x24" TAPCONS ON MASONRY: (2) SIMP. MSTAM24 16 MSTC28 w/(36)16d SINKERS CENTERED STUDS TO BEAM/GT 2980 3455 OT 5-1/4"x5-1/4" LVL COLUMN. 17 MSTC40 w/ (52)16d SINKERS CENTERED STUDS TO BEAM/GT 4305 4745 TO POST: (2) SIMP. HTS20 OR LSTA18 OV 5-1/4"x7" LVL COLUMN. ON MASONRY: (2) SIMP. MSTAM24 18 LTT20B w/(10) 10d NAILS & 8" EPDXY ANCHOR w/SIMP. SET EPDXY MIN. 7" EMBEDMENT COLUMN TO FTG.OR CMU 1290 1300 5.25x16 (3)1.75"x16 " LVL * U.N.O.FASTEN LVL PLIES TOGETHER USING (3) ROWS OF 1/4" X 3 1/2" SDS SCREWS @ 24" O.C. EACH SIDE XO 7"x7" LVL COLUMN. 19 HTT4 w/(18) 16d x 22' NAILS w/B' EPDXY ANCHOR w/SIMP. SET EPDXY MIN. 7" EMBEDMENT - AT LVL / PSL COLUMNS USE 18 #10x1-1/2" SD SCREWS INSTEAD OF NAILS COLUMN TO FTG. 3640 4235 YO 3 1/2" X 11 7/8" LVL COLUMN 20 (3)HTS20 w/(24)10d x 12' NAILS (AT EXT LOCATIONS INCLUDE (3)12d TOENAILS) FRAME TO FRAME 3735 4350 63.5x20 (2) 1.75"x20" LVL TO POST: (2) SIMP. HTS20 OR LSTA18 ON MASONRY: (2) SIMP. MSTAM24 <Z> 5 1/4 X 9 1/2 LVL COLUMN 21 MSTCM40 W/ (14) 16d SINKERS AND (10) 1/4"x2-1/4" TITENS FRAME TO CMU 2420 2800 * U.N.O.FASTEN LVL PLIES TOGETHER USING (4) ROWS SOF IIDE/4"X31/2"SDS SCREWS @ 24" O.C. EACH STANDARD COLUMN NOTES 22 SIMPSON HGUS 5.50/10 W/ (63) 16d NAILS GIRDER TO COL./ BM 9100 4095 1. NAIL ALL BUILT-UP STUDS PER DTL. WF08/SD3. 2. ALL POST/ LVL COLUMNS IN EXTERIOR CONDITION SHOULD STANDARD BEAM NOTES 23 MGT w/ (22) 10d NAILS TO GIRDER & (1) 5/8" A.T.R. THRU DBL. TOP PLT. TO INVERTED HDU5 ATTACHED TO POST. FRAME TO FRAME 3300 3965 BE P.T. OR WOLMANIZED. INVERTED HUD5 TO POST w/ (14) 1/4" x 2 1/2" SDS SCREWS 1. NAIL ALL (2) 2x SYP BEAMS TOGETHER USING (3) ROWS OF 12d NAILS @ 12" O.C. (TYP. ONE SIDE) MIN. 2" FROM TOP AND BOTTOM OF BEAM 3. CONTRACTOR TO USE ABU BASE CONNECTORS @ SPF/SYP SOLID POSTS. AT EXTERIOR CONDITIONS STANDARD CONNECTOR NOTES 2. NAIL ALL 2 -PLY LVL BEAMS (MAX. TOGETHER 4x4: ABU44 w/(12)16d NAILS & s EPDXY ANCHOR WMIN. 12d NAILS @ 6" O.C. TYP. ONES E)1MIN 2" FROM TOP AND BOTTOM OF BEAM 7" EMBEDMENT 6x6: ABU66 w/(12)16d NAILS & $" EPDXY ANCHOR w/MIN. 1. ALL TRUSS/BEAM TO MASONRY CONNECTIONS TO BE SIMP. HETA16/20, U.N.O. ON PLAN. 3. VERIFY w/PLAN CORRECT LENGTH OF BEAM REQ'D. (MIN. 4" BRG. EA. END) 7" EMBEDMENT 8x8: ABU88 w/(1 8)16d NAILS & (2) $" EPDXY ANCHORS w/ MIN. 7" EMBEDMENT AT FLOOR TRUSSES PARALLEL TO MASONRY WALLS CONNECT w/SIMP. LTA2's @ 24"o.c. OR 32"o.c. VERIFY w/ TRUSS SHOP DRAWINGS FOR VERTICAL SPACING WITHIN FLOOR TRUSS. (IF SITTING ON FRAME WALL USE SIMP. LSTA18(14) @ 24"o.c. OR 32"o.c.) 4. SEE PLAN FOR TOP OR BOTTOM OF BEAM INDICATIONS. 5. BEAMS ARE NOT TO BE DRILLED OR NOTCHED IN ANY WAY WITHOUT 4. POST/LVL INSTALLED WITHIN BRG. WALL TO BE WITHIN TOPWRITTEN AND BASE PLATE U.N.O. ON PLANS. CONNECT ALL CONTINUOUS RIM BOARDS TO TOP OF MASONRY W/SIMP. LTA2, @ 32"o.c. MAX. AND (2) AT EACH CORNER. APPROVAL FROM THE E.O.R. 5. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS. 2. ALL TRUSS/BEAM TO FRAME CONNECTIONS TO BE SIMP. H10A FOR SINGLE PLY, OR H10A-2 6. SEE STRUCTURAL COVER SHEET FOR LVL SPECIFICATIONS FOR 2 -PLY U.N.O. ON PLAN STANDARD NAIL SCHEDULE 3. CONNECT ALL TYPICAL HIP JACKS (CORNER JACKS) TO FRAME USING SIMP. H2.5A CONNECTOR. IF UPLIFT EXCEEDS 535lbs USE (2) H2.5A CONNECTORS. >TANDARD NAIL GENERAL DIAMETER/ LENGTH 4. CONNECT ALL INTERIOR FLOOR TRUSSES/JOISTS TO INTERIOR BRG. WALLS USING (3)12d TOENAILS. 5. ALL TRUSS TO TRUSS CONNECTIONS TO BE SPECIFIED BY TRUSS MANUFACTURER, U.N.O. ON PLAN. 8d 131" x 22" 6. MISSED LINTEL STRAPS: CONTRACTOR TO INSTALL SIMP. HTSM16 @ EACH MISSED HETA16/20 10d .148" x 3" STRAP LOCATION. IF DOUBLE HETA16/20 @ A 2 -PLY OR 1 -PLY TRUSS IS MISSED, USE (2)HTSM16 STRAPS. IF UPLIFT IS HIGHER THEN 2100lbs, CONTACT E.O.R. FOR FURTHER REVIEW. 12dI 148"x34" FLOOR FRAMING NOTES 16d162"x32 GENERAL NOTES 8d RING SHANK .113" x 28" 1. FLOOR JOIST/TRUSS HANGERS SUPPLIED & ENGINEERED BY FLOOR JOIST/TRUSS CO. 2. REFER TO TRUSS MANU. DRAWINGS FOR TRUSS DESIGNATIONS. 3. GENERAL FLOORING FINISHES ARE ACCEPTABLE. IF LIGHTWEIGHT CONCRETE OR SELF LEVELING CONCRETE IS REQ. CONTACT E.O.R. ALONG WITH TRUSS CO. TO VERIFY FLOOR TRUSS DESIGN. NAILING NOTES 4. FLOOR JOIST/ TRUSS MANUFACTURER SHALL COORDINATE LOCATIONS OF ALL MECHANICAL CHASES AND PLUMBING TO AVOID CONFLICT. 1. CONTRACTOR MAY USE A DIFFERENT NAIL THEN 5. ALL JOIST TO JOIST OR TRUSS TO TRUSS CONNECTIONS SHALL BE SPECIFIED BY THE MANUFACTURER. INDICATED AS LONG AS IT MEETS OR EXCEEDS THE 6. G.C./BUILDER SEE ARCHITECTURAL DRAWINGS FOR ROUGH OPENING LOCATIONS AND ADDITIONAL INFORMATION DIAMETER AND LENGTH INDICATED. REQ. FOR DOOR AND WINDOW INSTALLATION ALONG WITH DIMENSIONS NOT SHOWN HERE. 2. CONNECTORS MAY USE DIFFERENT NAIL LENGTHS. FLOOR SHEATHING NOTES MINIMUM NAIL LENGTH PER CONNECTOR IS REQ. IF LONGER FLOOR SHEATHING TO BE 3/4" PLYWOOD OR OSB (U.N.0), WITH LONG DIMENSION NAIL IS USED IT IS ADEQUATE AS LONG AS IT DOES NOT PERPENDICULAR TO SUPPORT (FLOOR TRUSSES). EXTEND THRU THE MEMBER IT'S BEING ATTACHED TO. FLOOR NAILING NOTES NAILS: NAILS USED IN ALL FLOORING APPLICATIONS SHALL BE 8d, 8d RING OR SPIRAL SHANK, HAND OR GUN DRIVEN NAILS. GUN DRIVEN NAILS SHALL HAVE HEAD SIZE EQUIVALENT TO HAND DRIVEN NAILS, SPACING SHALL BE 6" ON EDGES AND 12" IN FIELD. J g z w 0 LU 0 Ftz O w H cfl NOTES & CONNECTOR LEGEND.. COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. F- 91.9 O Oa F- 8 z Z 0 z Z Z z�co O w W��� U w v ~ ��o�o� o W 0 0 U) 46 (Dwza .� M ZQzO J�o N M J-jO�o}o °8 �- W :3(0 0w"cca �Qp�2w o Zo=zwz E F- O OZI-WYO WUw<wW ='^ Z Z�oLo W M 0 O o V � 11-- 00 � J W>> W O W W n W Z w Q 0 o. b co Q WYAG O Z � Q O BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 0) Uj X 00 °•� Aq; v U_ &% 0 �;J�_ J 2 z W;v LU ~a p: z� p ``:0- w o :` 'till LL F- 91.9 O Oa F- 8 z Z 0 z Z Z z�co O w W��� U w v ~ ��o�o� o W 0 0 U) 46 (Dwza .� M ZQzO J�o N M J-jO�o}o °8 �- W :3(0 0w"cca �Qp�2w o Zo=zwz E F- O OZI-WYO WUw<wW ='^ Z Z�oLo W M 0 O o V � 11-- 00 � J W>> W O W W n W Z w Q 0 o. b co Q WYAG O Z � Q O BLDG DESIGN: --- STRUCTURAL ENG: MCD DRAFTING: -DESIGN: --- -STRUCT: WM QC CHECK: CC JOB No. PSQ-0205409 SCALE: AS INDICATED DATE: 06-13-18 • r'— r- w 111A A' d.. d LU > z ENTIRE COLUMN TO a BE GROUT FILLED Uj w U.It 1. Iii N.O. U d � : •... it All 4 v a PROVIDE STANDARD HOOK (1) #5 IN TIE BEAM (1) #5 BAR IN PRECAST LINTEL (2) #5's VERTICAL IN GROUT FILLED CELL (1) #5 VERTICAL IN GROUT FILLED CELL (IF REQ'D PER PLAN) NOTE: SEE MD08 ON LINTEL PLAN VERTICAL REINFORCEMENT DETAIL NOTE: THIS DETAIL APPLIES TO THE FOLLOWING CONDITIONS: (1) EXTERIOR FRAME WALL TO CMU (2) INTERIOR FRAME SHEAR WALL TO CMU (3) INTERIOR LOAD BEARING FRAME WALL TO CMU WALL SEE FRAMING PLAN FOR BEARING WALL LOCATION SEE BEARING WALL SCHEDULE FOR REQUIRE[ CONNECTIONS, STUD SPACING, AND BLOCKING REQUIREMENTS ALTERNATE CONNECTIONS I.L.O. J -BOLT: 1. MIN. (6) 1/2"x5" TITEN HD W/ 3-1/2" MIN. EMBED. 2. MIN. (6) 1/2" ASTM F1554, Gr. 36 (OR BETTER) THREADED ROD W/4-1/2" MIN. EMBED. W/ SIMPSON SET -XP EPDXY OR EQUIV. USE 2"x2" SQUARE WASHER BEARING/ SHEARWALL CONNECTION TO CMU 2x BUCK DETAIL 3/4"=1'-0" PRE -CAST LINTEL PER PLAN OPENING WATERPROOFING BY BUILDER/ OTHERS WINDOW/DOOR OPENING SIZE AND LOCATION PER PLAN (TYP). MASONRY WALL PER PLAN (TYP). P.T. BUCKS PER SCHEDULE (2) 2x TOP PLATE W/ (3) 12d END NAILS TO LAST STUD TYPICAL TIE BEAM W/ 3000 psi CONC. W/(1) #5 REBAR CONT. STD HOOK 2x PT STUD OR ALTERNATE 1x PT FURRING TO CMU W/ 2x FRAMING PER PLAN TYPICAL FILLED CELL W/ 3000 psi CONC. W/(1) #5 REBAR VERT. VERIFY W/ PLAN FOR REQ'D LOCATIONS CMU WALL AS REQ'D PER PLAN 4) EQ. SPACED 2' TITEN HD ANCHORS W/ AIN. 12" EMBEDMENT FOR HOLLOW 3LOCK OR 3 1/2" EMBEDMENT FOR SOLID 3LOCK. MAX. 6" FROM TOP AND BOTTOM )R 1/4" TAPCON W/ MIN. 2" EMBEDMENT 6" =ROM TOP AND BOTTOM AND 12" O.C. 3ETWEEN PT BASE PLATE P.T. BUCK FASTENER SCHEDULE M SIZE TAPCONS SPACING # ROWS 1x4 3/16" x 2 1/4" 12" O.C. 1 � (2) 2x TOP PLATE 3/16" x 2 1/4" 121, EXT. AS NOTED 1x8 3/16" x 2 1/4" 12" O.C. 2 2.w FOR BEAM SIZE (ONLY ATTACHED TO MI N. 2x4 3/16" x 3 1/4" 12" O.C. 1 (2) 2x FULL HEIGHT /1 " 1/4" " PER PLAN) 2x8 3/16" x 3 1/4" 12" O.C. 2 NOTES: 1. 2x SYP #2 P.T. BUCKS/NAILERS MAY EXTEND BEYOND INT. FACE OF WINDOW/DOOR. FASTEN BUCK TO MASONRY PER FASTENER SCHEDULE 4" FROM ENDS AND 16" O.C. MAX. TAPCONS TO BE 1 1/2" MIN. FROM EDGE OF BUCK. 2. BUCKS LESS THAN 2x SYP #2 TO BE FASTENED W/CUT NAILS OR EQUIVALENT, STRUCTURAL CONNECTION OF WINDOW/DOOR TO STRUCTURE BY OTHERS IN THIS CASE. 3. ADDITIONAL 2x SYP #2 P.T. WOOD BUCK MATERIAL MAY BE ADDED TO EXISTING 2x BUCKED OPENING, USE (3) ROWS OF 10d x 3" NAILS STAGGERED @ 12" O.C. AND 6" FROM ENDS @ EACH SUCCESSIVE BUCK. MAX. 2 PLIES OVER INITIAL P.T. BUCK. 4. MIXING OF 1 x AND 2x BUCKS SHALL BE PERMITTED FOR THE SAME OPENING IF WINDOW/DOOR MANUFACTURER AND PLAN REQUIREMENTS (FASTENING) ARE MET. 5. MAINTAIN MAXIMUM 2" FASTENER EMBEDMENT INTO HOLLOW OR SOLID GROUTED CMU. 6. WINDOW OR DOOR INSTALLATION BY OTHERS SHEATHING PER PLAN TYP. TRUSS TO FRAME CONNECTION PER STD.CONNECTOR NOTES FRAME OUT TO BLOCK EDGE AS REQ'D LAST STUD OF KNEE WALL i \ }s JOINING UP TO MAIN HOUSE WALLS SHALL BE ATTACHED (2) 2x TOP PLATE TO MIN. (2) 2x FULL HEIGHT WALL STUDS W/ (2)-16d NAILS @ 12" O.C. MIN. 2x4 SPF #2 KNEE WALL i (2) 2x #2 SYP SEE PLAN WITH STUDS @ 16" O.C. W/ FOR BEAM SIZE STRUCTURAL SHEATHING ON BOTH SIDES FROM TOP BUILDER FRAME OF WALL TO BOTTOM OF RADIUS AS REQ'D BEAM. ATTACHED PER NAILING SCHEDULE OTHERWISE SP2 CLIPS EACH STUD TO DOUBLE TOP PLATE AND SP1 CLIPS EACH STUD TO BOTTOM PLATE FO KNEEWALL AT DOWNSET BEAM PRE-ENGINEERED — ROOFTRUSS-SEE FRAMING PLAN FOR SPACING SEE PLAN FOR --� CONNECTION 2x BRG WALL, SEE — PLAN FOR STUD SIZE & SPACING. MIN (2) 2x UNDER GIRDER TRUSS U.N.O. 2x BLOCKING ---_ SIMPSON LSTA24 EACH STUD 3/4"=1'-0" ROOF SHEATHING, NAIL PER PLAN DOUBLE TOP PLATE SIMPSON SP4 OR SP2 @ EACH STUD EXTERIOR SHEATHING NAIL PER PLAN 2x BRG WALL, SEE `— PRE -ENG. ROOF PLAN FOR STUD SIZE & TRUSS PER PLAN SPACING. MIN (2) 2x UNDER GIRDER TRUSS SEE PLAN FOR U.N.O. CONNECTION F1 SECTION @ DOUBLE BEARING PRE-ENGINEEF TRUSSES PER 24" 0. C. MAX. TYP. TRUSS T( CONNECTION CONNECTION EXT. SHEATHIP PER NAILING E TOP OF KNEE% OR SP2 CLIPS CLIPS AT BASE 2x BLOCKING MIN 2x4 STUD O/C 2x P.T. PLATE 1/2" x 8" A.B. OF O.C. & 6" FRON CENTER ON BF TOP KNOCK 01 COURSE W/ (1) CONT. 3/4"=1'-0" (2) 2x PLATE LAST STUD OF i KNEE WALL JOINING UP TO MAIN HOUSE WALLS SHALL BE ATTACHED TO MIN. (2) 2x FULL HEIGHT WALL STUDS W/ i (2)-16d NAILS @ 12" O.C. MIN. 2x4 SPF #2 KNEE WALL WITH STUDS @ 16" O.C. W/ STRUCTURAL SHEATHING ON BOTH SIDES FROM TOP OF WALL TO BOTTOM OF BEAM. ATTACHED PER NAILING SCHEDULE NFO KNEEWALL AT UPSET BEAM (2) 2x BUILT-UP COL. 2x BLOCKING W/ — (2) 12d NAILS @ EACH END SIMPSON LSTA30 W/ (22) 10d NAILS (ALL CORNER CONDITIONS STRAP AROUND TALLER STUD) (2) 2x TOP PLATE ATTACH 2x TO — BUILT-UP W/ (2) ROWS OF 10d NAILS STAGGERED @ 8" O.C. INS KNEEWALL ABOVE MASONRY WALL SHEATHING PER PLAN TYP. TRUSS TO FRAME CONNECTION PER STD.CONNECTOR NOTES FRAME OUT TO BLOCK EDGE AS REQ'D (2) 2x #2 SYP SEE PLAN FOR BEAM SIZE BUILDER FRAME RADIUS AS REQ'D 3/4"=1'-0" (2) 2x TOP PLATE SEE FLOOR PLAN FOR MORE BRG. WALL INFO 3/4"=1'-0" IF REQ'D, PROVIDE CLOSURE WALL w/ SINGLE TOP AND BASE PLATE w/ (2) 16d NAILS TO TRUSS. STUDS @ 24" O.C. & EXT. SHEATHING INSTALLED PER NAILING PATTERN CRICKET AS REQUIRED MAIN SPAN ROOF TRUSS UPLIFT CONNECTOR (SEE SCHEDULE) MASONRY WALL PER PLAN STRUCTURAL SHEATHING TYP. TRUSS TO FRAME CONNECTION PER STD.CONNECTOR NOTES FRAME OUT TO BLOCK EDGE LAST STUD OF M CONTRACTOR MAY ELECT TO BUCKET SHORT SPAN BEAM INTO LONG SPAN AS INDICATED ON BEAM Z. KNEE WALL JOINING STRAP IS NOT REQUIRED. Qco � (2) 2x TOP PLATE UP TO MAIN HOUSE • = Uj J EXT. AS NOTED (2) 2x #2 SYP SEE PLAN WALLS SHALL BE LAP BEAM PLYS AND 2.w FOR BEAM SIZE (ONLY ATTACHED TO MI N. NAIL AS SHOWN (5) U_ IF OPENING PROVIDED (2) 2x FULL HEIGHT 0.131 x 3 1/4" NAILS PER PLAN) WALL STUDS W/ PER PLY (2)-16d NAILS @ 12" 2x4 SPF #2 KNEE WALL O.C. W/ STUDS @ 16" O.C. POST TO BEAM CO O W/ STRUCTURAL 1/2" x 8" ANCHOR BOLT NOTED PLAN VIEW @ TOP OF POST SHEATHING FROM OR TITEN HD @ 32" PT POST (AS NOTED) TOP OF WALL TO O.C. & 6" FROM EACH ABU POST BASE BOTTOM OF WALL. END o' ATTACHED PER 2x PT BOTTOM 0 o. NAILING SCHEDULE PLATE ' OTHERWISE SP2 CLIPS PRECAST LINTEL OREACH • STUD TO BEAM KNOCK OUT COURSE a• ABOVE AND SPI CLIPS EACH STUD TO MASONRY WALL BOTTOM PLATE FO KNEEWALL AT MASONRY WALL 3/4"=1'-0" \ ° SEE FOUNDATION PLAN FOR ADDITIONAL INFO SIDE VIEW @ BASE OF POST CORNER COLUMN FRAMING CONC. SLAB - SEE FOUNDATION PLAN FOR MORE INFO SEE FOUNDATION __j DETAILS FOR FTG INFO 3/4"=1'-0" PRE-ENG.TRUSS PER PLAN, 24" O.C. MAX ROOFING MATERIAL PER ARCHS SEE FRAMING PLAN FOR CONNECTION INFO SEE ELEVATION TOP OF MASONRY SEE ARCH PLANS FOR OVERHANGINFO RE. ELEV. FOR O.H. TYP. SINGLE TIE -BEAM W/ (1) #5 CONT. GROUT SOLID W WINDOW PER FLOOR PLAN PRECAST CONC. OR POWERS STEEL SILL TYP. @ ALL WINDOWS EXT FINISH PER PLAN MAIN FLOOR ELEV 0'-0" VERT REINF. BEYOND MASONRY WALL PER PLAN TYPICAL ONE STORY CMU WALL SECTION 3/4"=1'-0" COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTH CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTH CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC is strictly prohibited. J Q z w 0 co LU X 0 z O M CONTRACTOR MAY ELECT TO BUCKET SHORT SPAN BEAM INTO LONG SPAN AS INDICATED ON BEAM Z. SCHEDULE. IF BUCKET IS INSTALLED THE SHORT SPAN STRAP IS NOT REQUIRED. Qco •Z PT. POST (AS NOTED) • = Uj J EXT. AS NOTED Co 00�:�Z®- Q LUz o LAP BEAM PLYS AND 2.w o NAIL AS SHOWN (5) U_ i 0.131 x 3 1/4" NAILS U_ PER PLY O HTS20 CLIP FROM POST TO BEAM CO O W EXTERIOR BEAM AS NOTED PLAN VIEW @ TOP OF POST PT POST (AS NOTED) U ABU POST BASE (AS NOTED) o' 5/8" THREADED ROD w/ 0 o. NUT SET IN ADHESIVE \ ° SEE FOUNDATION PLAN FOR ADDITIONAL INFO SIDE VIEW @ BASE OF POST CORNER COLUMN FRAMING CONC. SLAB - SEE FOUNDATION PLAN FOR MORE INFO SEE FOUNDATION __j DETAILS FOR FTG INFO 3/4"=1'-0" PRE-ENG.TRUSS PER PLAN, 24" O.C. MAX ROOFING MATERIAL PER ARCHS SEE FRAMING PLAN FOR CONNECTION INFO SEE ELEVATION TOP OF MASONRY SEE ARCH PLANS FOR OVERHANGINFO RE. ELEV. FOR O.H. TYP. SINGLE TIE -BEAM W/ (1) #5 CONT. GROUT SOLID W WINDOW PER FLOOR PLAN PRECAST CONC. OR POWERS STEEL SILL TYP. @ ALL WINDOWS EXT FINISH PER PLAN MAIN FLOOR ELEV 0'-0" VERT REINF. BEYOND MASONRY WALL PER PLAN TYPICAL ONE STORY CMU WALL SECTION 3/4"=1'-0" COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTH CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTH CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC is strictly prohibited. J Q z w 0 co LU X 0 z O w 0 d' 2 U 1 0 0 z �.- Q to Q W c O zJ W p W 2 LLJ o �Z� a. �Mg x U � Q = LIJ O Y Z z Q O 0 a a N W BLDG DESIGN: --- 0 STRUCTURAL ENG: MCD C -- W DRAFTING: -DESIGN: --- -STRUCT: WM U — QC CHECK: CC u) JOB No. PSQ-0205409 Q SCALE: AS INDICATED w DATE: 06-13-18 w SD1 M �(/ ss•o•••e••••v�/� rs W00 Z. i °• 2` Y ° 6•i ems. J Z Qco •Z a7 _ • = Uj J Co 00�:�Z®- Q LUz o 0 2.w o z o, U_ i U_ O CO O W U 0 Q 0- - w O J J Q U W Z O J 0- 2 U D � z Q (� co w W b z U W LL O U z O U > ° I .J 8Ix $ U z U 2" 1�" z o U W z 77 -OC o Z U_ �Fl - (/) W •- W UnFW. Z - U _ J��CO� O Q 06 co O N ° U0 - W ZQ°�� W W JU1-00 P o F- ~ W �U�OQvc ZQO�2z ° W ~ (� p=zw E O z Y o W / W 2 � Ha<O� a = U_ O U o O O U Q z w 0 d' 2 U 1 0 0 z �.- Q to Q W c O zJ W p W 2 LLJ o �Z� a. �Mg x U � Q = LIJ O Y Z z Q O 0 a a N W BLDG DESIGN: --- 0 STRUCTURAL ENG: MCD C -- W DRAFTING: -DESIGN: --- -STRUCT: WM U — QC CHECK: CC u) JOB No. PSQ-0205409 Q SCALE: AS INDICATED w DATE: 06-13-18 w SD1 SIMPSON DIAGONAL TO BEAM SIMPSON HGA10 @ 48" O.C. SHEATHING NOT REQ'D TO BE CONT. @ THE TRANSITION FROM BEAM TO GABLE TRUSS BEAM PER PLAN SIMPSON DIAGONA PLATE SIMPSON HGA10 @ 48" O.C. SHEATHING NOT REQ'D TO BE CONT. @ THE TRANSITION FROM WALL TO GABLE TRUSS DOUBLE 2x TOP PLATE FASTEN SIDE WALL SHEATHING PER PLAN. EXT. SHEATHING; ATTACH PER PLAN BEAM CONNECTION FRAME WALL CONNECTION REQ'D GABLE END "L" AND/OR "T" BRACING STRONG BACK PER GABLE END BRACING CHART 2x4 SYP #2 TOP CHORD BRACING @ 16" O.C. MIN (2) TRUSS BAYS CONTRACTOR TO FIELD VERIFY WHICH BACK FROM GABLE END (MIN. 48") GABLE END CONDITION IS REQUIRED. CONTACT EOR A23 DIAGONAL TO TRUSS PER FOR ADDITIONAL INFO AS REQ'D TRUSS BOTTOM PLAN TYP. CHORD. REFER TO SIMPSON A23 @ EACH GE02 FOR REQ'D MAINTAIN 3 1/4" H BEARING WALL PER BRACE TO PLATE BRACING TYP. O.C. ATTACH W/ (6) 1 O.C. MAX. STUD NAILS (MAX. 4" SPACING TO BE VERTICAL GAP CLEARANCE BETWEEN BETWEEN 12" LONG 16" O.C. MAX. @ 1/2" J -BOLTS w/ 2x4 SYP #2 BOTTOM LOADS SUCH AS TRUSS BLOCKING.) CABINETS OR HEAVY REDUCE DTC SPACI SHELVING. INSIDE FACE OF CMU WALLS CARRYING WASHERS (MIN. 6" CHORD BRACING @ 16" NON -LOAD BEARING CABINETS OR HEAV WALL DOWN 1-2' SHELVING BELOW BOTTOM OF PLYWOOD AND CENTERLINE OF 2x BLOCKING x 12" CHORD. EMBED) MIN. 6" FROM O.C. FOR FALSE BEAM LOCATION FOR CLIF ATTACHMENT, @ 41 SHEATHING & J -BOLT SINGLE TOP PLATE EACH END AND 32" ATTACHMENT W/ (3) NAILING PER O.C. MAX. z 10d TOENAILS EA. END Z O w PLAN SHALL O = in MIN. (2) TRUSS BAYS = RUN CONT. 2x8 P.T. PLATE, CANT. Q Z BACK FROM GABLE M Of w D J ACROSS GABLE FOR CLG. NAILING WEND (MIN. 48") > W TO BOTTOM OF SURFACE c=n U UL FALSE BEAM. m 2x TOP PLATE TO > o U ATTACHED PER PROVIDE 16d NAILS 0 GABLE END W/ 12dNAILING ' U GABLE END TRUSS TO = NAILS @ 6" O.C. W SCHEDULE PLATE @12" O.C. MAX. HGA10 @ 32" O.C. 2x4 SYP #2 FRAMING FOR FALSE 0 0 Z O Q U BEAM @ 16" O.C., IF REQ'D W/ (4) O WJ TIE BEAM COURSE w/ 10d NAILS @ EA. TRUSS BRACE W = H W J ~ CMU WALL OR LINTEL (1) #5 CONT. TOP AND BOTTOM F- 2x4 #2 SYP BELOW MIN. 2x4 SYP #2 STUDS @ 16" O.C. W W BLOCKING W/ SINGLE BOTTOM & TOP PLATE BETWEEN W/ (3) 10d NAILS EACH END TYP. STUDS ONLY IF CMU WALL CONNECTION FALSE BEAM FRAME DOWN 2x4 SYP #2 HORIZONTALPER PLAN IS A SINGLE 2x BLOCKING @ 16" O.C. W/ (3) 10d IF REQ'D WIDE NAILS EACH END CLEAR SPAN CONNECTION ***NOTE: REFER TO DETAIL GE02 THIS PAGE FOR GABLE BRACING*** GABLE END @ FLAT CEILING CONNECTIONS 3/4"=1'-0" (150 MPH EXP. B) 2x4 SYP #2 BLOCKING @ 48" O.C. MAX. W/ (3) 12d TOE -NAILS @ EA. ROOF SHEATHING PER END. REDUCE PLAN ATTACH PER SPACING TO 24" O.C. NAILING SCHEDULE @ WALLS CARRYING LOADS SUCH AS CABINETS OR HEAVY SHELVING SIMPSON DTC @ EACH HORIZONTAL BLOCK LOCATION. ATTACH W/ (6) 8d NAILS (MAX. 4" VERTICAL GAP BETWEEN 12" LONG BLOCK & TRUSS BOTTOM CHORD/ TRUSS BLOCKING.) 2x BLOCKING x 12" LONG @ HORIZONTAL BLOCKING LOCATION FOR CLIP ATTACHMENT. ATTACH TO WALL SINGLE TOP PLATE W / MIN. (4) 8d NAILS. SINGLE 2x TOP PLATE F2 NON-BEARING WALL (PARALLEL TRUSS) 1/211=11-0.1 TRUSSES AT 24" 0.( TYP. NON -LOAD H BEARING WALL PER SIMPSON DTC @ 48' PLAN. STUDS @ 24" O.C. ATTACH W/ (6) 1 O.C. MAX. STUD NAILS (MAX. 4" SPACING TO BE VERTICAL GAP REDUCED DOWN TO BETWEEN 12" LONG 16" O.C. MAX. @ BLOCK & TRUSS LOCATIONS CARRYING BOTTOM CHORD/ LOADS SUCH AS TRUSS BLOCKING.) CABINETS OR HEAVY REDUCE DTC SPACI SHELVING. TO 24" O.C. FOR WALLS CARRYING HOLD TOP OF LOADS SUCH AS NON -LOAD BEARING CABINETS OR HEAV WALL DOWN 1-2' SHELVING BELOW BOTTOM OF TRUSS BOTTOM 2x BLOCKING x 12" CHORD. LONG @ TRUSS O LOCATION FOR CLIF ATTACHMENT, @ 41 O.C. ATTACH TO WA SINGLE TOP PLATE MIN. (4) 8d NAILS. SINGLE 2x TOP PLAT 2x4 BLOCKS, (2)16d NAILS @ EA. END. BLOCK NOTE: ALL GABLE ADJ. BAYS @ EA. DIAG. AS SHOWN. FASTEN BRACING IS TO BE ROOF SHEATHING TO BLOCKS W/ 8d NAILS @ SYP#2 OR BETTER 6" O.C. (4) BAYS MIN (1) BAY AFTER BRACE IS REQ'D) (5) 16d NAILS BRACE TO BLOCKING PROVIDE 2x4 BRACE TO EA. ADJ. DIAG. FASTEN TO DIAG. w/(2) 16d NAILS. \ GABLE BRACING @ 48" O.C. NOT REQ'D 6' FROM EAVES GABLE BRACING CHART H GABLE BRACING + UP TO 4'-8" NO BRACE REQUIRED 4'-8" < H 6 7'-0" (1) 2x4 BRACE 7'-0" < H:6 9'-4" (2) 2x4 BRACE (SEE SECTION A -A) 9'-4" < H 614'-0" STRONGBACK W/ (1) 2x4 BRACE 14'-0" < H618'-8" STRONGBACK W/ (2) 2x4 BRACE A -A GABLE VERTICAL BRACING GABLE END BRACING 2x4 BRACE IF REQ'D SEE CHART. 10d COMMON NAILS @ 6" O.C. GABLE VERTICAL 2ND 2x4 BRACE IF REQ'D, SEE CHART 3/4"=1'-0" WHERE O.H. IS > V-0", DROP GABLES w/ OUTLOOKERS @ 24" O.C. TO RUN V-0" MAX PLYOOD CANT. O.H. BACK TO 1 ST COMMON TRUSS WITH SEE ELEV. FOR (3) 12d TOENAILS. CONNECT TO O.H. SIZE DROP GABLE WITH H2.5 CLIP. MAX 2'-0" O.H. \ L CONT. 2x4 \ 2x4 DIAGONAL BRACE @ 48" O.C. TO 3RD BAY \ \ REQ'D w/ \ STRONGBACK, SEE \ CHART \ \ GABLE BRACING (+) SEE CHART TYP. NON -LOAD BEARING WALL PER PLAN. STUDS @ 24" O.C. MAX. STUD SPACING TO BE REDUCED DOWN TO 16" O.C. MAX. @ LOCATIONS CARRYING LOADS SUCH AS CABINETS OR HEAVY SHELVING. HOLD TOP OF NON -LOAD BEARING WALL DOWN 1--l" BELOW BOTTOM OF TRUSS BOTTOM CHORD. STRONGBACK IF REQ'D PER CHART A GABLE END SHEATHING FASTEN PER SEE GABLE CONNECTION DETAIL FOR REQ'D CONNECTIONS 2x4 ATTACHED TO EA. GABLE 2x4 BRACE WITH (2) 10d NAILS (1) A23 FROM — STRONGBACK TO DIAGONAL 2x6 10d COMMON NAILS @ 8" O.C. LEDGER @ LOW ROOF STRUCTURAL SHEATHING ATTACHED PER NAILING SCHEDULE 2x4 #2 SYP CONT. W/ (2) 16d COMMON NAILS EA. STUD OR TRUSS MEMBER, TYP. (MAX. 24" O.C.). IF MASONRY, USE (2) 1/4" TAPCONS W/ MIN. 2" EMBED. @ 24" O.C. TRUSS OR ROOF SYSTEM WOOD/MASONRY WALL OR TRUSS, SEE PLAN 3/4"=1'-0" STUD U.N.O. SEE BEARING WOOD WALL SCHEDULE ON NOTES & CONNECTOR LEGEND SHEET FOR MORE INFORMATION NOTE: REQUIRED NUMBER OF KING STUDS PER THE HEADER SUPPORT SCHEDULE ON NOTES & CONNECTOR LEGEND SHEET. QUANTITY OF KING STUDS SHOWN ON FRAMING PLANS SHALL SUPERSEDE THE QUANTITY AS SHOWN ON STANDARD DETAILS (2) ROWS 12d NAILS STAGGERED @ 12" O.C. EA. FACE OR (3) ROWS 12d NAILS STAGGERED @ 12" O.C. FOR 2X10 OR GREATER HEADER LSTA30 HEADER TO STUDS U.N.O. DOWNFRAME TO DOOR SIM TO WF01/SD3 2X STUDS TYP. ATTACH JAMB STUDS PER WF08/SD3 BASE PLATE TO BE ATTACHED TO FTG USING 1/2" 0 J -BOLTS OR EPDXY ANCHOR @ 6" FROM EA. END OF BASE PLATE & WALL OPENINGS & 32" O.C. W/ 7" MIN EMBED. & 2" WASHER. AT SLAB STEP DOWNS, EMBED. MUST BE 7" BELOW STEP P.T BASE PLATE NOTE: JACK STUDS SHALL BE INDICATED ON FRAMING PLANS BY THE DIAMOND DESIGNATION AND SHALL BE THE BEARING SUPPORT MEMBERS FOR HEADERS. IF NO JACK STUD DESIGNATIONS ,ARE SHOWN, REFER TO THE HEADER SUPPORT SCHEDULE ON NOTES & CONNECTOR PER HEADER SCHED. THEN ATTACH ADDIT'L KINGS AS REQ'D. TYPICAL HEADER DETAIL 2X CRIPPLES @ 16" O.C. W/ SIMPSON SP2 TYP. TOP AND BOTTOM IF HEADER IS NOT FLUSH AGAINST TOP PLATE * WHEN STUD LENGTH IS < 12" USE LSTA30 STRAPS AT EA. STUD WRAPPED OVER TOP PLATE & NAILED TO HEADER EA. SIDE W/ (11) 10d NAILS SP4 TOP OF CRIPPLE AT STRAP LOCATION (2) ROWS 12d NAILS STAGGERED @ 12" O.C. EA. FACE OR (3) ROWS 12d NAILS STAGGERED @ 12" O.C. FOR 2X10 OR GREATER HEADER SEE HEADER SCHEDULE FOR HEADER CONNECTION INFORMATION LSTA30 HEADER TO STUDS U.N.O. FILLING AND BLKING AS REQ'D W/ (2) ROWS OF 12d @ 16" O.C. TO HEADER UNO 2X STUDS TYP. ATTACH JAMB STUDS PER WF08/SD3 BASE PLATE TO BE ATTACHED TO FTG USING 1/2" J -BOLTS OR EPDXY ANCHOR @ 6" FROM EA. END OF BASE PLATE & WALL OPENINGS & 32" O.C. W/ 7" MIN EMBED PER BRG WALL SCHEDULE. AT SLAB STEP DOWNS, EMBED. MUST BE 7" MIN. BELOW STEP P.T BASE PLATE SP4 @ BASE OF EA. STUD U.N.O. SEE BEARING WALL SCHEDULE ON NOTES & CONNECTORLEGEND SHEET FOR MORE INFO. 1/2"=1'-0" COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING & DESIGN, OF WMR & ASSOCIATES, LLC is strictly prohibited. J Q z w 0 W 0 z O L: 0 W 0 ����11119111i��ar 11/1111111111 M O , �X W a _ U•s�a••r�•s�se o v ��`!li �e •• fJ 6 � ui 00 Z or co ti O O: J . J _ Z U �. LU Q �S ¢ Q Qi O;�e �: Z LLI Q a. W ����i�8 * pf��`� O o W ci ti O o_ Z 11-- 0 — 00 o J z a Q W O LLJ z �-�w = W y W W I'_ OWCZa 302 ~ Ut a= 0 � Y o W Q O z d O. N W BLDG DESIGN: --- U STRUCTURAL ENG: MCD W DRAFTING: U #00 sYl 0- " z am X ti w WV�w OU — F- E JCD�COr-- °tS - 0 1n (�WZpM�,c Z I— Z > J 00 = _ � I—V-m"'� c �o a> -a 8 �U)-01zv- M ZQp3�w o 0= Z w Z E O< Ww 7: ��O�ga iz M Oo 0 0 11 -DESIGN. E—-STRUCT: WM U -- QC CHECK: CC (0 JOB No. PSQ-0205409 J — Q SCALE: AS INDICATED QDATE: 06-13-18 U) w D2_ 11/1111111111 ccU_ O Z o T W O cc Q a. W O J Q Lu J Z O O U z z a U U) M Of w D Q = > W U U_ O U) z O > o U " L u.i J ' U W O U 0 0 0 Z O Q U O WJ W = H W J ~ W F- n V U z W W o U U) U Q z W ci ti O o_ Z 11-- 0 — 00 o J z a Q W O LLJ z �-�w = W y W W I'_ OWCZa 302 ~ Ut a= 0 � Y o W Q O z d O. N W BLDG DESIGN: --- U STRUCTURAL ENG: MCD W DRAFTING: U #00 sYl 0- " z am X ti w WV�w OU — F- E JCD�COr-- °tS - 0 1n (�WZpM�,c Z I— Z > J 00 = _ � I—V-m"'� c �o a> -a 8 �U)-01zv- M ZQp3�w o 0= Z w Z E O< Ww 7: ��O�ga iz M Oo 0 0 11 -DESIGN. E—-STRUCT: WM U -- QC CHECK: CC (0 JOB No. PSQ-0205409 J — Q SCALE: AS INDICATED QDATE: 06-13-18 U) w D2_ 2x4 BLOCKS, (2) 1E' - NAILS @ EA. END. BLOCK ADJ. BAYS EA.DIAG. AS SHOV FASTEN ROOF SHEATHING TO BLOCKS w/8d NAIL @ 6" O.C. (5) 16d NAILS BRA( TO BLOCKING PROVIDE 2x4 BRA( TO EA. ADJ. DIAG. FASTEN TO DIAG.v 16d NAILS. GABLE BRACING C O.C. MAX. 45° FRO HORIZONTAL (+/- 1 BRACE NOT REQU 6' FROM EAVES. PROVIDE BLOCKI� BETWEEN TRUSS @ 48" O.C. FOR FII BAYS WALL PER PLAN CONNECTION DETAIL —" V� (FRAME WALL SHOWN; FOR REQ'D MAY ALSO BE CONNECTIONS MASONRY) 'NOTE: GABLES SPANNING LESS THAN 8' DO NOT REQUIRE BRACING*** 4THING PER PLAN RE O.H. IS > V-0", P END GABLE w/ _OOKERS @ 24" TO RUN BACK TO 'OMMON TRUSS I (3) 12d TOENAILS. NECT TO DROP _E WITH H2.5 CLIP. 2'-0" O.H. T. 2x4 @ 24" O.C. LE END 4THING FASTEN PLAN :,E AS REQ'D 'SON H10A DIAG. LOCKING VIDE 2x BLOCKING NAILING SS PER PLAN PLAN FOR SORT AND TIE IN OF JACK 3SES GABLE END @ FLAT CEILING W/ BOSTON HIP 2x6 COLLAR TIE HALF WAY - UP HEIGHT OF VALLEY. FASTEN w/ (5) 10d COMMON NAILS @ EACH END (TYP.) 2x6 RAFTER TO 2x8 RIDGE BOARD W/ A35 ON ONE SIDE OF RAFTER. ATTACH A35 ON ADJ RAFTER TO OPP SIDE (AS SHOWN) FASTEN SYP OR SPF 2X6 (MIN. WIDTH) PLATE THRU O.S.B SHEATHING (THICKNESS PER PLAN) TO PRE -ENG TRUSS BELOW W/ 1/4"x4-1/2" SIMPSON SDS SCREWS 2x6 PLATE TO TOP CHORD OF EACH TRUSS BELOW 2x6's @ 24" O.C. MAX. ,F01 FIELD FRAMED VALLEY DETAIL 01" c \�O s ti D 2x SCAB w/ 10d NAILS O.C. MAX. @ 4" O.C. PROVIDE (4)10d x3" PER -ENG TRUSSES NAILS AT JOINT PER PLAN 2x SCAB w/ 10d NAILS 1' @ 4" O.C. TRUSS CONNECTION PER -ENG TRUSSES PER PLAN 2x FASCIA PER PLAN 3/4"=1'-0" I o I I I I I 1/2"=1'-0" BUILDER NOTE: SOFFIT FRAMING NOT REQUIRED WITH ALUMINUM OR VINYL SOFFITS ROOF SHEATHING, FASTEN PER PLAN 2x4 FRAMING @ 24" CMU WALL PER PLAN (2) 8d TOE NAILS TO TRUSS CONNECTION LEDGER PER PLAN 2x4 PT LEDGER W/ 1/4 x4' TAPCONS @ 12 2x FRAME WALL PER O.C. PLAN SEE ELEV. FOR O.H. SIZE 710k JP - 2X8 RIDGE BOARD - FASTEN CONV. 2x VALLEY RAFTER FRAMING (OR PRE -ENG VALLEY TRUSSES) TO 2x PLATE WITH SIMPSON MTS12 OR LSTA12 CONNECTORS ((5) 8d NAILS) @ EA. RAFTER TO PLATE CONN. 2o90 F qo To Cr T4.. ROOF SHEATHING, FASTEN PER PLAN 2x4 FRAMING @ 24" O.C. MAX. PROVIDE (4) 10d x 3" NAILS AT JOINT �— 2x FASCIA (2) 8d TOENAILS TO LEDGER 2x4 LEDGER W/ (2) 16d NAILS @ 16" O.C. EE ELEV. FOR CONDITION @ CMU WALL CONDITION @ FRAME WALL TYPICAL SCAB OVERHANG PRECAST LINTEL PER PLAN MASONRY WALL SEE PLAN 2x8 W/ (2) 16d TOE NAILS EA. END 2x SPF CONT. BLOCKING ATTACH TO 7/16" OSB W/ (2) 8d NAILS 7/16" OSB EA. SIDE, W/ 6d NAILS @ 16" O.C. TO SIDE & TOP NAILER 2x BUCK PER DETAIL MD04/SD1 NOTE: CUT BACK 2x8 P.T. @ TOP TO ALLOW CONT. 2x4 BLOCKING AROUND CURVE. MIN. 2 TAPCON ANCHORS ARCH WINDOW FRAMING DETAILS 3/4"=1'-0" ARCH PER ELEV LINTEL (SEE PLAN) 7/16" O.S.B. EA. SIDE 4; 2x BLK'G. TO O.S.B. (2) - 8d EACH END END VIEW w/ CMU HEADER (SEE PLA* ARCH PER ELEV NOTES: 1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES OF THE COLUMN 2) ALL NAILS PENETRATE AT LEAST 3/4" OF THE THICKNESS OF THE LAST LAMINATION 3) FOR 5 -PLY, PROVIDE 1/4"DIA. x 5 1/2" LAG SCREWS OR EQUAL (SPACE AS SHOWN FOR 3 -PLY) 4) TOLERANCES: ALL DIMENSION TO BE HELD WITHIN +/- 1/4" 1" EDGE 1 1/2" EDGE 10d x 3 COMMON 61.1 1 p102 1/2" Z w 1 1/2" WN N r N N N I I N 10d x 3" COMM( 10d x 3" COMMON OPP. SIDE (2) 2x4's C7 Z U Q a 00 I 110d x 3" COMM( A OPP. SIDE (2) 2x6's TYPICAL BUILT-UP STUD COLUMN DETAIL DORMER FRAMING DETAIL 7/16" O.S.B. EA. SIDE 2x BLK'G. TO O.S.B. (2) - 8d EACH END END VIEW w/ WOOD 2 1/2" EDGE (2) 2x8's (2) 2x COLUMN `)EE TYPICAL HEADER RAMING DETAILS FOR kDDITONAL VFORMATION HEADER CAN BE :ITHER UPSET OR )OWNSET) !x W/ (2) 16d TOE NAILS :ACH END 3) 16d COMMON JAILS (TYP.) OUTSIDE (2) 2x4's 0 Z Q 0.. ao z C a U a EDGE DISTANCE PER DETAIL INSIDE PLY NAILS NAILED AT 8" O/C STAGGERED. OUTSIDE NAILS NAILED AT 8" O/C. OUTSIDE 2x's (3+) 2x COLUMN O2x STUDS @ 16" O.C. FOR KNEE WALL LSTA18 @ 32" O.C. STUD TO PRE -ENG TRUSS, SLIT OB ROOF SHEATHING FOR STRAP CO CONT. ROOF SHEATHING NAIL PER PLAN PROVIDE 2x4 BLOCKING w/(2)16d NAILS EACH END \, !,, O TO TOP CHORDS OF TRUSSES BELOW WHEN 1 BOTTOM PLATE DOES NOT LINE UP ABOVE TRUSS BELOW AND CONNECT w/ HTS20 @ 32" O.C. OPRE-ENGINEERED ROOF TRUSS PER PLAN BELOW 2x PLATES OVER ROOF DECK PER VALLEY w FRAMING DETAIL ODOUBLE TOP PLATE OSIMPSON H3, H4, OR H5 @ EA. END OF TRUSS OR RAFTER TRUSS PER PLAN OR CONV. FRAMING w/ JOCOMMON STRUCTURAL SHEATHING PER PLAN AND ROOF z° FINISH PER ARCHITECTURAL PLANS U ROOF TRUSSES PER PLAN OR CURVED OCURVED K RAFTERS w/ (2) LAYERS 3/4" CDX SHEATHING -�. NAILED @ 6" O.C. STAGGERED NOTE: SEE ARCH ELEVATION FOR FRONT WINDOW OPENING IF REQ'D NOTE: ROOF SHEATHING MUST BE APPLIED AND FASTENED TO BASE 1/2"=1'-0" TRUSS PER PLANS BEFORE DORMER FRAMING IS INSTALLED. !x4 SPF CONT. 3LOCKING ATTACH TO 716" OSB W/ (2) 8d JAILS 716" OSB EACH SIDE, W 6d NAILS @ 16" O.C. -0 SIDE & TOP NAILER !x BUCKS, 10dx3" 10d x 3" OPP. SIDE kNCE PER COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC is strictly prohibited. J Q z w 0 w ti 0 N z O W Z O w x LLJ co w rr��►tiu►o�� ui 0)0 O ��• •. �2 : Y z° z z U -�. 0 w O:Z-Uj � Q • .� •• • �.• G, Q fL' 0 , d� •... i �,, .� >_ g LL w p r u►' a � LL O = U W z O W U Q 0 o_ U z O Co U 0 w —� $ w .o U z U W z _m 0 O U LL O ti c w WU�w z 0 _jrnco►- o UO J uj O cn N o C�WZ�M{,c J W z~ Z> J� 7 CD W F- W J z Q ~ W �U OWE ~ f•- ZQ0:;:M o E U uJ 0Q?WQp W QW I-3:O H Lo M OO o a W Z O LLJ O U CL z z U Q � vi w W � a � = U W LL O U z O Co U 0 ° —� $ w .o U z U W z _m 0 z U LL O ti c w WU�w z 0 _jrnco►- o UO uj O cn N o C�WZ�M{,c J W z~ Z> J� 7 CD W F- W J z �U0mU - J 0 D >- o coy ~ W �U OWE ~ f•- ZQ0:;:M o E U uJ 0Q?WQp W QW I-3:O 0 Lo M OO o a � _ z U) U t� O O 0 0 z �- Q U G O _j M ILLI 0WW = W W a Z °CO°- I=— U CQ= O W Z W W Q O Z G_ a. N (9 co W BLDG DESIGN: --- U STRUCTURAL ENG: MCD DRAFTIN(a -DESIGN: --- -STRUCT: WM QC CHECK: CC u)j JOB No. PSQ-0205409 J Q SCALE: AS INDICATED W DATE: 06-13-18 0 W D3Ln TRUSS PER PLAN 2x4 #2 SYP P.T. BLOCKING @ 24" O.C. W/(2)12d END NAILS @ EACH END TRUSS PER PLAN 2x4 BLOCKING (2) 1— NAILS, TOENAILED EACH END.AT 24" C TRUSS PER PLAN (2) 16d TOE NAILS BRACE TO LEDGER SIMPSON LTA2 BLOCKING TO CMU W/ 2x4 LEDGER W/ (2) ROOF SHEATHING PER PLAN DTC CLIP, (2) 8d NAILS INTO BLOCKING, (4) 8d NAILS INTO TOP PLATE DOUBLE TOP PLATE MASONRY WALL OR (10) 10d NAILS AND NAILS @ EACH WEB LINTEL SEE PLAN '.�P' MIN. 4 1/8" EXTERIOR SHEATHING. EMBEDMENT OR g ATTACH PER PLAN SIMPSON META16 a FROM TOP OF WALL STD CONDITION @ CMU w TO BOTTOM 2x8 #2 SPF STUDS AT SIMPSON DTC, (2) 8d 16" O.C. NAILS INTO BLOCKING, (4) 8d NAILS TO TOP MASONRY WALL OR 2x8 #2 SYP PT. BASE TRUSS PER PLAN A PLATE LINTEL SEE PLAN PLATE W/ 1/2" x 8" USS PER PLAN I SYP #2 BLOCKING, @ 24" O.C. W/ (2) 12d END NAILS @ EACH END. WALL SHEATHING PER PLAN 2x WALL, SEE PLAN STD CONDITION a@ FRAME WALL (4)10d NAILS @ EA. BLOCKING TO PLATE TRUSS PER PLAN TRUSS PER PLAN (2)10d NAILS TO BOTTOM CHORD @EACH END OF BLOCKING 2x4 SYP #2 FLAT (2)10d NAILS TO BLOCKING, @ 24" O.C. BOTTOM CHORD W/ (2) 12d END NAILS @EACH END OF @EACH END. BLOCKING WALL SHEATHING PER PLAN 2x WALL, SEE PLAN ALT. BLOCKING @FRAME CONDITION WFO NON-BEARING WALL CLIP DETAIL 3/4"=1'-0" (150 MPH EXP. B) NOT USED ANCHOR BOLT OR TITEN HD @ 32" O.C. & 6" FROM EACH END VAULTED CONDITION @ CMU TRUSS PER PLAN SIMPSON LTA2 TRUSS TO CMU W/ (10) 10d NAILS & MIN. 4 1/8" EMBEDMENT OR SIMPSON HGAM10 W/ (4) 1/4" x 1 1/2" SDS SCREWS & (4) 1/4" TAPCONS OR EQUAL MAINTAINING MIN. 2" EMBEDMENT @ ENDS, OTHERWISE 24" O.C. U.N.O. ON FRAMING PLANS v— LAY 2x4 SYP #2 BLOCKING OVER THE TOP OF THE BOTTOM LINTEL PER CHORD. ATTACH W/ (2) 10d PLAN NAILS @ EACH TRUSS 24" O.C. MAX. BLOCKING SHALL EXTEND A MIN. OF (1) TRUSS BAY EACH SIDE OF BOND BEAM, TYP. BEARING CONDITION @ CMU WALL NOTE: PLATE LENGTHS MUST BE AT LEAST V-0" LONG. TYP. TOP SPLICE @ - DOUBLE 2X4 TOP PLATE ATTACH 2x4 STUDS TO TOP PLATE W/ (3) 12d TOE -NAILS TYPICAL AT ALL LOCATION BOTTOM SPLICE OVER STUD PIPE OR DUCT W/ PENETRATION OF MORE THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON PSPN516Z W/ (12) 16d NAILS TYP. TOP & BOT. (2) 10d NAILS @ 3" O.C. WITHIN 48" OF SPLICE THEN (2) ROWS 10d NAILS @ 8" O.C. OTHERWISE 48h TYPICAL TOP PLATE SPLICE () BRG. WALL 3/4"=1'-0" (2) 10d NAILS @ 3" O.C. — WITHIN 48" OF SPLICE THEN (2) ROWS 10d NAILS @ 8" O.C. OTHERWISE ATTACH 2x4 STUDS TO TOP PLATE W/ (3) 12d TOE -NAILS TYPICAL AT ALL LOCATION 2x4 WALL BEYOND — AGAINST 2x8 STUDS ATTACHED PER (WF08/SD3) ATTACH 2x8 STUDS TO TOP PLATE W/ (4) 12d TOE -NAILS TYPICAL AT ALL LOCATION DOUBLE 2x4 TOP NAIL FIELD INSTALLI PLATE TOP PLATE TO FRAN PROVIDE 2x4 ON TOP WALL OR PRE - OF 2x8 TO PAD OUT ASSEMBLED WALL TOP PLATE. ATTACH PANEL W/ (2) 10d NA W/ (2) 10d NAILS 3" O.C. @ 8" O.C. (FOLLOW NAILING (SOLID BLOCK W/ 2x6) REQUIREMENTS THI DETAIL FOR ALL TOF PLATE SPLICE LOCATIONS) I j r, TOP SPLICE — DOUBLE 2x8 TOP PLATE TOP PLATE TRANSITION (2X4 TO 2X8 WALLS) MIN. 15/32" EXP 1 OR 7/16 STRUCTURAL 0 NAIL SHEATHING AT FRAME WALL BOTTOM PLATE & 2x DBL TOP PLATE 1 SHEATHING INSTALLED VERTICALLY AT FLOOR SYSTEM (I -JOIST OR SYSTEM42 / FLAT BEYOND711-@ OR HORIZONTALLY TRUSS) TOP & BOTTOM USING (1) ROW OF 8d NAILS @ Z 3" O.C. SEE WS10 AND WS11 FOR ADDITIONAL INFO. I — — — — — TT- — -TI — — Tr- — I T— TRUSS AND v O 2O NAIL AT DOUBLE TOP PLATE USING (2) ROWS OF 8d INSTALLED ABOVE, FASTEN PLAN TYP. WALL SPLICE, FIELD w ? JJ Q NAILS @ 3 O.C. 5 I I I I I I VERIFY IF REQUIRED a= Z) w � O3 NAIL OPENING PERIMETER w/ (2) ROWS OF 8d NAILS SHEATHING W/ 8d NAILS 6" SDS SCREWS @ 16" O.C. AT EDGES AND 12" O.C. w w IN FIELD. FASTEN TOP TO MASONRY w/ 2x4 PT PLATE TO VERTICAL STUDS SYP #2 LEDGER w/ 1/4" a. O @ 3 O.C. IN HORIZONTAL CONDITIONS ROOF TRUSSES @ 24" I I I I HGAM10 TOP AND BOTTOM mU z 0 ® NAIL INT. W/ 8d NAILS @ 12" O.C. & NAIL EDGES 6" O.C. O U III WALL SHEATHING O = U.N.O. ON PLANS. STAGGER ALL VERT. PANEL JOINTS III III III I I I I I I III I I I I I SPLICE, SEE SPLICE DETAIL. MAX 1/8" 5O PLYWOOD SPLICES @ HEADER - NAIL SHEATHING TO OPENING ADDITIONAL HGAM10 FROM SPACE BETWEEN w w HEADER W/ 8d NAILS @ 3" O.C. (2) ROWS @ TOP & III III 4 I I PANELS w CD BOTTOM III II II II II WRITTEN � SPECIFICATIONS III 3 III I II II J � III III I I I I I I `2 w EXTERIOR SHEATHING AROUND 2x STUDS BEYOND, U_ 0 III OPENING III I I I I I I SEE PLAN FOR MORE Of U_ PROVIDE PIECE OF III III II I I I INFO � Z_ la- O SHEATHING BETWEEN _ _ _ III —11 JiT III I I I I I I U) Z O w= "' EXTERIOR WALL I I I I I I I I I I I I I I I I I I ai Q O w SHEATHING & BLOCKING. I I—IL--i ILL—JI--LL—JL_ D J 0 ~' J= �0 SHEATHING TO HAVE �� cnm SAME THICKNESS& 0 " O U_ 00 STRENGTH ORIENTATION FLOOR SYSTEM "LL AS EXTERIOR WALL — — — — — — — — — — — — — — - HE CUT TO FIT 2x BOTTOM PLATE STUD PER PLAN JOINT, MAX. 1/8" GAP OPENING SIZE 1 BEYOND SEE PLAN SHEATHING DIAGRAM 2x6 BLOCKING PLACED (2) ROWS OF 8d NAILS ir FLATWISE W/ (2) 16d @ 3" O.C. TOP & BOT. F1 EXTERIOR SHEATHING SCHEDULE NAILS EACH END OF SHEATHING SPLICE SCALE: 3/4"=1'0" GYPSUM WALLBOARD SHFATHINr. SPI irF nFTAII PLATE . ,., PLATE TO EACH PLY OF BUILT UP COLUMN BELOW W/ (2) 10d NAILS TOP PLATE CORNER TRANSITION A4 yi, D= NAIL SPACING - ° ° PER NOTE #2 M N T 1 M D I I SHEATHING PER PLAN WALL DOUBLE TOPD/2 I ��s PLATE PER PLAN DOUBLE NAIL EDGE SPACING SHEATHING PER PLAN 3/8" S= NAIL SPACING S S PER NOTE #1 M M SINGLE NAIL EDGE SPACING PRE ENGINEERED SHEATHING PER PLAN TRUSS AND IF PERPENDICULAR TRUSS CONNECTIONS PER INSTALLED ABOVE, FASTEN PLAN TYP. 2x8 #2 SYP TOP PLATE TO SDS SCREWS @ 16" TRUSS W/ (2) 12d TOENAILS O.C. MAX.; 2x8 SYP #2 P.T. VERTICAL @ TO GABLE END STUDS 16" O.C. FASTEN EXT. a < SHEATHING W/ 8d NAILS 6" SDS SCREWS @ 16" O.C. AT EDGES AND 12" O.C. O.C. MAX.; IN FIELD. FASTEN TOP TO MASONRY w/ 2x4 PT PLATE TO VERTICAL STUDS SYP #2 LEDGER w/ 1/4" W. (4) 12d NAILS x 2 3/4" TAPCONS @12" ROOF TRUSSES @ 24" O.C. HGAM10 TOP AND BOTTOM o PLATE TO CMU WALL W/ (4) O U 1/4" x 1 1/2" SDS SCREWS & (4) D01 TYPICAL SHED ROOF DETAIL 1/4" x 2 3/4" TAPCONS TO CMU ° @ 32" O.C. & MIN. 6" FROM ENDS. IF HEADER HEIGHT EXCEEDS 2'-0" ADD AN �... ADDITIONAL HGAM10 FROM 00 CENTER OF EACH STUD TO POCKET SGD CMU @ 32" O.C. MAX ATTACHMENT BY (2) 2x8 SYP #2 P.T. BOTTOM BUILDER. REFER TO PLATE W/ (3) 12d NAILS @ MANUFACTURER'S EACH VERTICAL, EACH PLY. WRITTEN STAGGER NAILS AS SPECIFICATIONS REQUIRED SO HEADER @ POCKET SLIDER 1 /2"=1'-0" NOTE: MIN. 15/32" OR 7/16" STRUCTURAL 1 SHEATHING. SHEATHING TO BE EXPOSURE 1 RATED AND CAN BE INSTALLED EITHER VERTICALLY OR HORIZONTALLY 1/8" MAX GAP REQUIRED BETWEEN EXTERIOR SHEATHING AND MASONRY/CONCRETE UNLESS FELT PAPER IS PRESENT. 1/8" GAP BETWEEN SHEETS OF PLYWOOD TO BE MAINTAINED NOTE: CONTRACTOR TO TAKE CARE NOT TO OVER DRIVE NAILS. IF NAILS ARE OVERDRIVEN, THE ENTIRE SHEET OF SHEATHING IS TO BE REMOVED & REPLACED. IF MORE THAN 50% OF THE SHEATHING IS OVERDRIVEN, CONTACT EOR FOR REVIEW OF EXTERIOR STUDS EXTERIOR WALL/TRUSS 12 4 (MIN.) SIMPSON H3 CLIP 2x6 SYP #2 LEDGER. TO STUDS w/ (2) 1/4" X 4'/z" SIMPS. SDS SCREWS @ 16" O.C. MAX.; TO GABLE END STUDS W/ (2) 1/4" X 3'/" SIMPS. SDS SCREWS @ 16" O.C. MAX.; TO MASONRY w/ 2x6 PT SYP #2 LEDGER w/ (2) 1/4" x 2 3/4" TAPCONS AT 12" O.C. 1/2"=1._011 COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC is strictly prohibited. J Q F z w 0 w 0 N z 0 SHEATHING PER PLAN 2x4 SYP #2 LEDGER. TO STUDS OR BEAM w! (4) 10d NAILS FOR (2) 1/4" X 4'/" SIMPS.7 CONV. FRAMED SDS SCREWS @ 16" MEMBERS ONLY O.C. MAX.; TO GABLE END STUDS w/ (2) 1/4" X 3%" SIMPS. 3'-0" MAX w SDS SCREWS @ 16" FASCIA PER O.C. MAX.; COMMUNITY SPECS TO MASONRY w/ 2x4 PT 2x4 SYP #2 OR SYP #2 LEDGER w/ 1/4" PRE-ENGINEERED x 2 3/4" TAPCONS @12" ROOF TRUSSES @ 24" O.C. O.C. MAX. SIMPSON H3 CLIP DESIGNED FOR O U SHINGLE ONLY D01 TYPICAL SHED ROOF DETAIL YZ 1/2"=1._011 COPYRIGHT MCD 2015: The information contained in this document is copyrighted and is the exclusive property of MONTA CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC. Any use, duplication, or transfer of these documents without the expressed, written consent of MONTA CONSULTING &DESIGN, OF WMR &ASSOCIATES, LLC is strictly prohibited. J Q F z w 0 w 0 N z 0 w I— co wrn i d O U a�SIN �% ! `�•'°•••• i �i ••••••• �4` YZ GD ' o z 00 d� � ez :w ;R; Q �: = U o W cis 6•�.) z N O= t�? .6 ` z �5 '& X1, m `2 U_ 0 U) Z O W D Q 0 0 w 0- ir w 0 J J Q Z W O J O IZ U w o U Q U5 "' W Of 0 = W U tL O z 0 cn U ° ��//�� w W Aa= d LLI U ° Uo Wz. U m Z w CD ti � J �w W U w O < 0�rn�o� E Q °dUj0�r—M - O (�wzaMr c J W ZQ 0 J LLL. �� = J Z _j o v F_:)w 0w 0 w oQ?wg= LU a = Z�OM 0 0 w0 0 Q z 0 ci ti w (0 = O Z F- 2 0 00 z F-- -� a Q W c a W z 0 LU W 3: = Vi W F_ W Z M 0 w 0 0. Cy O Y Z z w Q O 0 - 0. N w BLDG DESIGN: --- 0 STRUCTURAL ENG: MCD w DRAFTING: j -DESIGN: --- -STRUCT: WM Of QC CHECK: CC CO JOB No. PSQ-0205409 J — SCALE: AS INDICATED W DATE: 06-13-18 0 F w SD4