Loading...
HomeMy WebLinkAbout3811 Caboose Pl 18-3411 Impact statementw- COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100006 BUILDING APPLICATION #: 18-10000676 BUILDING PERMIT NUMBER: 18-10000676 DATE: August 09 2018 UNIT ADDRESS: CABOOSE PL 3811 21-19-30-5SW-0000-0100 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: BOLDER PROPERTIES ADDRESS: 1740 SE 18th ST OCALA FL 34471 LAND USE: WAREHOUSE/OFFICE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 3811 CABOOSE PL / 7980 GSF WAREHOUSE W/2856 SF OFFICE FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS-ARTERIALS CO -WIDE Office ROADS -COLLECTORS N/A Office FIRE RESCUE N/A LIBRARY N/A SCHOOLS N/A PARKS N/A LAW ENFORCE N/A DRAINAGE N/A CREDIT FEES: SCI ROAD ARTERIALS C Warehousing* ORD 1,545.00 1.906 1000gsft 00 1.906 1000gsft 2,944.77 00 00 00 00 00 00 00 358.00 1.906 1000gsft 682.34- AMOUNT DUE 2,262.43 PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE DATE ABOVE BUT NO LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE BUSINESS OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO -LONGER VALID IF A BUILDING PERMIT IS NOT \" ISSUED WITHIN 60 CALENDAR DAYS FROM THE DATE ABOVE \ O CITY OF 0 AUG°2`3 Building &Fire Prevention Division 0 PERMITAPPLICATION FIRE DEPARTMENT a .: PPA lication No: " 3Yl ov Documented Construction Value: S , q 7 0 Job Address: 3811 Caboose Place Historic District: YesF—]Nov Parcel ID: 21-19-30-5SW 0000-0010 Residential Commercial Type of Work: Newt Addition Alteration Repair Demo[] Change of Use Move Description of Work: Additional Office Space Plan Review Contact Person: Gregory Edebohls Phone: 407-212-5321 Fag: None Title: PM Email: greg.edebohls@gmail.com Property Owner Information Name Bolder Properties, LLC - Street: 1740 SE 18th Street City, State Zip: Ocala, FL 34471 Phone: 352-620-2004 Resident of property?: No Contractor Information Name Wood Knot Construction Company LLC Street: 1191 Stanley Street City, State Zip: Longwood, FL 32750 Phone: 4.07-212-5321 Fax: State License No.: CBC1254482 Architect/Engineer Information Name: Castillo Engineering Services, LLC Street: 2381 Crest Ridge Court City, St, Zip: Sanford, FL 32771 Bonding Company: None Address: Phone: 407-474-9181 Fax: E-mail. rick@rcengineering.cc Mortgage Lender: None Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULS' WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6's Edition (2017) Florida Building Code 8 P 4- 3t 11 Revised: January 1, 2018 I 'j; Permit Application Wood Knot Construction Company August 8, 2018 Mr. Dan Fox 1805 SE 16th Ave., Suite 901 Ocala, FL 34471 1191 Stanley Street Longwood, FL 32750 407-831-6933 phone 407-831-6981 fax greg.edebohls@gmail.com CBC 125"82 r RE: 3811 Caboose Place Office Addition The following price is based on drawings by JHR Consultants CS, A-1, Mech, and HVACdated7-2-18. A: No Governmental Fees included in this proposal. B: Insulation is to be R30 for roof. Office walls to have R13 Insulation at warehouse walls and all interior walls to be insulated for sound control as needed. C: Painting- Included an allowance of $6,250 for all painting work. Figured Paintingallofficewalls, wood base trim, exterior warehouse/office wall, and steel doors andframes. D: Misc. Office- Included a $5,598 allowance for floor coverings. Included woodenbasemoldingsimilartowhatisinstalledatcurrentoffice. Office and Bathroom ceilings are to be a 2 x 2 acoustical ceiling grid with a 2 x 2 revealed edge whiteceilingtile. E: Cabinetry - Included simple custom built laminate cabinetry (base and wall cabinets) in a standard color for Breakroom. Did not include hot water heater for breakroom nor 'included a refrigerator. F: Plumbing- Included plumbing breakroom as per architectural drawings. G: HVAC- Includes a 5 ton with 10kw reheat coil 14 seer straight cool a/c unit with fiberglass ducted (supply and return) to each office area as called out on plans. H: Electrical- All Lights to be LED type fixtures. Included one outlet per wall asshownonplans. Total Cost of the Above: $63,970 Above includes allowance items: 1- Painting: $5,250 2- Carpet & Fir. Coverings: $5,598 CITY OF Building & Fire Prevention DivisionOIRADAUG0820.3 PERMITAPPLICATION FIRE DEPARTMENT : /'A A lication No: PP 3 7 / v Documented Construction Value: $ S -3 q 70 Job Address: 3811 Caboose Place Historic District: Yes No[Zl Parcel ID: 21-19-30-5SW-0000-0010 Residential Commercial Type of Work: New[Z] Addition Alteration Repair Demo[] Change of Use Move Description of Work: Additional Office Space ft." Plan Review Contact Person: Gregory Edebohls Phone: 407-212-5321 Fax: None Name Bolder Properties, LLC Street: 1740 SE 18th Street City, State Zip: Ocala, FL 34471 Title: PM Email: greg.edebohls@gmail.com Property Owner Information Phone: 352-620-2004 Resident of property?: No Contractor Information Name Wood Knot Construction Company LLC Phone: 407-212-5321 Street: 1191 Stanley Street City, State Zip: Longwood, FL 32750 Fax: State License No.: CBC1254482 Architect/Engineer Information Name: Castillo Engineering Services, LLC Phone: 407-474-9181 Street: 2381 Crest Ridge Court Fax: City, St, Zip: Sanford, FL 32771 Bonding Company: Address: None E-mail: rick@rcengineering.cc Mortgage Lender: None Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULS' WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 61 Edition (2017) Florida Building Code 7 0 I o. 5 8 Revised: January I, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date c- 1 >i4N FvA Print Owner/Agent's Name Lm/ap& -g-le Signature of Notary -State of Florida Date MICHELLE F MCMANUS c MY COMMISSION 0 GG091818 EXPIRES April 09, 2021 Owner gen 1s ersona y no to Me or Produced ID Type o Signature of BONITA'ROGhKs MY cOMMISSION S 6694207 EXPQtES: June 27, 2021 Date S 7'1g Date Contractor/Agent is Personall nown to Me or Produced 1D Typ BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: ,X e7 —Ip COMMENTS: Revised: January I, 2018 Permit Application 1 I VIT= I Construction Company August 8, 2018 Mr. Dan Fox 1805 SE 16th Ave., Suite 901 Ocala, FL 34471 RE: 3811 Caboose Place Office Addition 1191 Stanley Street Longwood, FL 32750 407-831-6933 phone 407-831-6981 fax greg.edebohls@gmail.com CBC 1254482 The following price is based on drawings by JHR Consultants CS, A-1, Mech, and HVAC dated 7-2-18. A: No Governmental Fees included in this proposal. B: Insulation is to be R30 for roof. Office walls to have R13 Insulation at warehouse walls and all interior walls to be insulated for sound control as needed. C: Painting- Included an allowance of $6,250 for all painting work. Figured Painting all office walls, wood base trim, exterior warehouse/office wall, and steel doors and frames. D: Misc. Office- Included a $5,598 allowance for floor coverings. Included wooden base molding similar to what is installed at current office. Office and Bathroom ceilings are to be a 2 x 2 acoustical ceiling grid with a 2 x 2 revealed edge white ceiling tile. E: Cabinetry - Included simple custom built laminate cabinetry (base and wall cabinets) in a standard color for Breakroom. Did not include hot water heater for breakroom nor included a refrigerator. F: Plumbing- Included plumbing breakroom as per architectural drawings. G: HVAC- Includes a 5 ton with 10kw reheat coil 14 seer straight cool a/c unit with fiberglass ducted (supply and return) to each office area as called out on plans. H: Electrical- All Lights to be LED type fixtures. Included one outlet per wall as shown on plans. Total Cost of the Above: $63,970 Above includes allowance items: 1- Painting: $5,250 2- Carpet & Fir. Coverings: $5,598 INSPECTION SEQUENCE BP# 18-3411 ADDRESS: 3811 Caboose Place BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall 10 Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In 20 Frame 30 Insulation Rough Firewall Screw Pattern 40 Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com' 1) Building Ceiling Grid Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial — 1000 Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) yE'L•`E .TRICAL PERMIT Min Max Inspection Description Electric Underground Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough 10 Electric Rough Pre -Power Final Temporary Pole 1000 Electric Final Inspection Description I Min Max Rough Plumb 10 Plumbing Underground 20 Plumbing 2"d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough 1000 Plumbing Final MBE .gK#NIGA,LPERMIT Min Max Inspection Description 10 Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap. Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap 1000 Mechanical Final REVISED: June 2014 CITY OF 1. Building & Fire Prevention DivisionA0 AUG 0 c`i ZH'`3 PERMIT APPLICATION FIRE DEPARTMENT a. , /_ J (/ Application No: j ov Documented Construction Value: $ S - q 7 Job Address: 3811 Caboose Place Historic District: Yes Nol—VI Parcel ID: 21-19-30-5SW 0000-0010 Residential[] Commercial Type of Work: New Addition[--] Alteration Repair Demo[] Change of Use Move Description of Work: Additional Office Space Plan Review Contact Person: Gregory Edebohls Phone: 407-212-5321 Fag. None Title: PM Email: greg.edebohls@gmail.com Property Owner Information Name Bolder Properties, LLC' - Phone: 352-620-2004 1740 SE 18th Street ` Street: Resident of property?. NO City, State Zip: Ocala, FL 34471 Contractor Information Name Wood Knot Construction Company LLC phone:407-212-5321 Street: 1191 Stanley Street Fax: City, State Zip: Longwood, FL 32750 State License No.: CBC1254482 Architect/Engineer Information Name: Castillo Engineering Services, LLC Street: 2381 Crest Ridge Court City, St, Zip: Sanford, FL 32771 Bonding Company: None Address: Phone: 407-474-9181 Fag: E-mail: rick@rcengineering.cc Mortgage Lender: None Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR E"PROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULS' WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 61b Edition (2017) Florida Building Code Revised: January 1. 2018 Permit Application CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 DATE: $ ,18-A S PERMIT NUMBER: BUSINESS/PROJECT NAME: j ADDRESS: 3 g/ leb3t, P/yca CONTACT NAME: PHONE: PLAN REVIEW INFORMATION WCONSTRUCTION [ ]C/O [) FIRE ALARM [) FIRE SPRINKLER [) HOOD [ )PAINT BOOTH [ )TANK DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES NO TOTAL FEES: 7f Wood Knot Construction Company August 8, 2018 Mr. Dan Fox 1805 SE 16th Ave., Suite 901 Ocala, FL 34471 RE: 3811 Caboose Place Office Addition 1191 Stanley Street Longwood, FL 32750 407-831-6933 phone 407-831-6981 fax greg.edebohls@gmaii.com CBC 1254482 The following price is based on drawings by JHR Consultants CS, A-1, Mech, and HVACdated7-2-18. A: No Governmental Fees included in this proposal. B: Insulation is to be R30 for roof. Office walls to have R13 Insulation at warehouse walls and all interior walls to be insulated for sound control as needed. C: Painting- Included an allowance of $6,250 for all painting work. Figured Paintingallofficewalls, wood base trim, exterior warehouse/office wall, and steel doors andframes. D: Misc. Office- Included a $5,598 allowance for floor coverings. Included wooden base molding similar to what is installed at current office. Office and Bathroom ceilings are to be a 2 x 2 acoustical ceiling grid with a 2 x 2 revealed edge whiteceilingtile. E: Cabinetry - Included simple custom built laminate cabinetry (base and wall cabinets) in a standard color for Breakroom. Did not include hot water heater for breakroom nor included a refrigerator. F: Plumbing- Included plumbing breakroom as per architectural drawings. G: HVAC- Includes a 5 ton with 10kw reheat coil 14 seer straight cool a/c unit with fiberglass ducted (supply and return) to each office area as called out on plans. H: Electrical- All Lights to be LED type fixtures. Included one outlet per wall asshownonplans. Total Cost of the Above: $63,970 Above includes allowance items: 1- Painting: $5250 2- Carpet & Fir. Coverings: $5,598 Florida Building Code, Sixth Edition (2017) - Energy Conservation EnergyGauge Summit® Fla/Com-2017, Effective Date: Dec 31, 2017 IECC 2015 - Total Building Performance Compliance O tion PERMti/fl _ 3 y OFFICE Check List Applications for compliance with the Florida Building Code, Energy Conservation shall include: This Checklist x The full compliance report generated by the software that contains the project summary, compliance summary, certifications and detailed component compliance reports. x The compliance report must include the full input report generated by the software as contigous part of the compliance report. K) Boxes appropriately checked in the Mandatory Section of the complaince report. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 1 of 21 PROJECT SUMMARY Short Desc: C0718349 Description: Smart Technologies of Flori Owner: Smart Technologies of Florida Addressl: 3811 Caboose Place City: Sanford Address2: State: FL Zip: 32771 Type: Office Class: Renovation to existing buildi Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Conditioned Area: 1866 SF Conditioned & UnConditioned Area: 6990 SF No of Stories: 1 Area entered from Plans 1866 SF Permit No: 0 Max Tonnage 4.8 If different, write in: EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31 /2018 Page 2 of 21 Compliance Summary Component Design Criteria Result Gross Energy Cost (in $) 1,955.0 2,213.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING 1 VAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES No Entry PASSES No Entry PASSES No Entry Yes/No/NA IMPORTANT MESSAGE Info 5009 -- — -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 3 of 21 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Building Official: COMMERCIAL ENERGY RATER #749 Date: n7-s1-7mrt Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (•) that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: Reg No: Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 4 of 21 Project: C0718349 Title: Smart Technologies of Florida Type: Office WEA File: F1,_ORLANDO_SANFORD_AMPORT.tm3) Building End Uses I)Proposed 2) Baseline Total 126.70 167.20 1,955 2,603 ELECTRICITY(MBtu/kWh/$) 126.70 167.20 37172 49025 1,955 2,603 AREA LIGHTS 61.50 52.70 18031 15444 948 820 MISC EQUIPMT 38.20 38.20 11205 11205 589 595 PUMPS 8 MISC 0.00 0.00 2 10 0 1 SPACE COOL 26.90 31.00 7889 9082 415 482 SPACE HEAT 0.00 0.10 3 30 0 2 VENT FANS 0.10 45.20 42 13254 2 704 Credits Applied: None PASSES Passing Criteria = 2213 Design (including any credits) =1955 Passing requires Proposed Building cost to be at most 85% of Baseline cost. This Proposed Building is at 75.1% EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 5 of 21 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP W/Unit) or No. of Units (VV) (VV) Sgft or ft) None Project: C0718349 Title: Smart Technologies of Florida Type: Office WEA File: FL_ORLANDO_SANFORD_AIRPORT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance Office Uncond Warehouse 17 Office -Enclosed 1,866 1 1 PASSES 3 Storage & Warehouse - Bulky 5,124 4 3 PASSES Active Storage PASSES Project: C0718349 Title: Smart Technologies of Florida Type: Office WEA File: FL_ORLANDO_SANFORD_AIRPORT.tm3) System Report Compliance AHU1 AHU1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr l Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 57000 14.00 13.00 8.00 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Heat Pumps Air Cooled 54500 8.20 8.20 PASSES Heating Mode) Split System 65000 Btu/h Cooling Capacity Air Handling Air Handler (Supply) - 1900 0.00 0.82 PASSES System -Supply Constant Volume Air Handling Air Handler (Return) - 1900 0.00 0.82 PASSES System - Return Constant Volume PASSES EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 6 of 21 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV fiance None Project: C0718349 Title: Smart Technologies of Florida Type: Office WEA File: FL_ORLANDO_SANFORD_AIRPORT.tm3) Water Heater Compliance Description Type Category Design Min Design Max Comp ER Eff Loss Loss fiance Water Heater 1 Electric water heater <= 12 [kW] 0.97 0.94 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance inches] Runout? Temp IBtu-in/hr Thick lin] Thick ]in) F] .SF.F] None EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31 /2018 Page 7 of 21 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory. Adopted with permission Topic Section Component Description Yes N/A Exempt I To be checked . Designer or Engineer Insulation C303.2 Envelope Below -grade wall insulation installed per manufacturer's instructions. Insulation C303.2 Envelope Slab edge insulation installed per manufacturer's 13instructions. Insulation C303.2 Envelope Above -grade wall insulation installed per 13 0manufacturer's instructions. Insulation C402.3 Envelope High-albedo roofs satisfy one of the following: 3-year-aged solar reflectance — 0.55 and thermal emittance — 0.75 or 3-year-aged solar reflectance index — 64.0. Fenestration C402.4.4 Envelope U-factor of opaque doors associated with the building thermal envelope meets requirements. SYSTEM SPECIFIC C403.2.12.1 Mechanical HVAC fan systems at design conditions do not O El exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM SPECIFIC C403.2.12.2 Mechanical HVAC fan motors not oversized beyond allowable 0 0limits. SYSTEM SPECIFIC C403.2.3(8) Table Mechanical Heat Rejection Equipment: Minimum Efficiency 13 0 Requirement meet those listed in Table C403.2.3(8) HVAC C403.2.7 Mechanical Exhaust air energy recovery on systems meeting 13® DTableC403.2.7(1) and C403.2.7(2). SYSTEM —SPECIFIC C403.3 Mechanical Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. SYSTEM SPECIFIC C403.3.2 Mechanical Economizer operation will not increase heating 13 D energy use during normal operation. SYSTEM —SPECIFIC C403.3.4, Mechanical Water economizers provided where required, C403.3.4.1, meet the requirements for design capacity, C403.3.4.2, maximum pressure drop and integrated C403.3.1 economizer control. SYSTEM —SPECIFIC C403.4.2.1 Mechanical Three -pipe hydronic systems using a common El 13returnforhotandchilledwaterarenotused. SYSTEM SPECIFIC C403.4.2.3.1 Mechanical Hydronic heat pump systems connected to a common water loop meet heat rejection and heat addition requirements. SYSTEM SPECIFIC C403.4.3.4 Mechanical Open -circuit cooling towers having water cooled chiller systems and multiple or vairable speed condenser pumps, are designed so that tower cells can run in parallel with larger of flow crtieria. SYSTEM SPECIFIC C404.2 Mechanical Service water heating equipment meets efficiency requirements. Wattage C405.3 Interior Lighting Exit signs do not exceed 5 watts per face. 2. To be checked by Plan Reviewer Plan Review C103.2 Envelope Plans and/or specifications provide all information 0 with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 8 of 21 Plan Review C103.2 Plan Review C103.2 Plan Review C103.2 Plan Review C103.2 Insulation Insulation HVAC Insulation Air Leakage SYSTEM SPECIFIC HVAC HVAC SYSTEM SPECIFIC SYSTEM SPECIFIC SYSTEM -SPECIFIC HVAC C402.2.5 C402.2.6 C402.2.6 C402.2.6 C402.5.7 C403.2.12.3 C403.2.13 C403.2.4.2 C403.2.4.4 C403.2.4.7 C403.2.5 C403.2.6.1 SYSTEM -SPECIFIC C403.4.1.1 SYSTEM -SPECIFIC C403.4.1.3 SYSTEM SPECIFIC C403.4.2 Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering st Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufact Interior Lighting Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided shoul Exterior Lighting Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided shout Envelope Slab edge insulation depth/length. Slab insulation extending away from building is covered by pavement or >= 10 inches of soil. Project Radiant heating systems panels insulated to R-3.5 on face opposite space being heated. Mechanical Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Envelope Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Envelope Vestibules are installed on all building entrances. Doors have self -closing devices. Mechanical Fans have efficiency grade (FEG) >= 67. The total efficiency of the fan at the design point of operation <- 15% of maximum total efficiency of the fan. Mechanical Unenclosed spaces that are heated use only radiant heat. Mechanical Each zone equipped with setback controls using automatic time clock or programmable control system. Mechanical Zone isolation devices and controls installed where applicable. Mechanical Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. Mechanical Hot water boilers supplying heat via one- or two -pipe systems include outdoor setback control. Mechanical Demand control ventilation provided for spaces 500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Mechanical Hydronic and multizone HVAC system controls areVAV fans driven by mechanical or electrical variable speed drive per Table C403.4.1.1. Mechanical Reset static pressure setpoint for DDC controlled VAV boxes reporting to central controller based on the zones requiring the most pressure. Mechanical Temperature reset by representative building loads in pumping systems for chiller and boiler systems >500,000 Bluth. 0 n u F u EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 9 of 21 SYSTEM —SPECIFIC C403.4.2.3.2.1 Mechanical Closed-circuit cooling tower within heat pump loop have either automatic bypass valve or lower leakage positive closure dampers. Open -circuit tower within heat pump loop have automatic valve to bypass all heat pump water flow around the tower. Open- or cl SYSTEM SPECIFIC C403.4.2.4 Mechanical Hydronic systems greater than 500,000 BUM designed for variable fluid flow. SYSTEM —SPECIFIC C403.4.2.5 Mechanical System turndown requirement met through multiple single -input boilers, one or more modulating boilers, or a combination of single -input and modulating boilers. Boiler input between 1.0 MBtu/h and 5 MBtu/h has 3:1 turndown ratio, boiler input between 5.0 SYSTEM —SPECIFIC C403.4.2.6 Mechanical Chilled water plants with multiple chillers have capability to reduce flow automatically through the chiller plant when a chiller is shut down. Boiler plants with multiple boilers have the capability to reduce flow automatically through the boiler plant SYSTEM —SPECIFIC C403.4.3, Mechanical Fan systems with motors —7.5 hp associated 1313C403.4.3.2 with heat rejection equipment to have capability to operate at 2/3 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. SYSTEM SPECIFIC C403.4.4.5 Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM —SPECIFIC C403.4.4.6 Mechanical Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. SYSTEM —SPECIFIC C404.2.1 Mechanical Gas -fired water -heating equipment installed in 130 new buildings: where a singular piece of water -heating equipment — 1,000 kBtu/h serves the entire building, thermal efficiency — 90 Et. Where multiple pieces of water -heating equipment serve the building wi SYSTEM SPECIFIC C404.4 Mechanical All piping insulated in accordance with section details and Table C403.2.10. SYSTEM —SPECIFIC C404.5, C404.5.1, Mechanical Heated water supply piping conforms to pipe C404.5.2 length and volume requirements. Refer to section details. SYSTEM —SPECIFIC C404.6.3 Mechanical Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to — 5 minutes after end of heating cycle. SYSTEM —SPECIFIC C404.7 Mechanical Water distribution system that pumps water from a heated -water supply pipe back to the heated -water source through a cold -water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving Wattage C405.5.1 Exterior Lighting Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Plan Review C405.6 Project Group R-2 dwelling units have separate electrical meters. Plan Review C406 Project Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. SYSTEM SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have means to balance and have pressure test connections. SYSTEM SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have means to balance and have pressure test connections. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 10 of21 Insulation C303.1 Envelope Insulation C303A Envelope Fenestration C303.1.3 Envelope Fenestration C303.1.3 Envelope Insulation C303.2, C402.2.4 Envelope Insulation C303.2.1 Envelope Insulation C303.2.1 Envelope Insulation C402.1.3 Envelope Insulation C402.2.2 Envelope Insulation C402.2.2 Envelope Air Leakage C402.5 Envelope Air Leakage C402.5.1 Envelope Air Leakage C402.5.1.1 Envelope Air Leakage C402.5.1.2.1 Envelope Air Leakage C402.5.1.2.2 Envelope Air Leakage C402.5.2, C402.5.4 Envelope Air Leakage C402.5.3 Envelope Air Leakage C402.5.5, Envelope C403.2.4.3 Air Leakage C402.5.5, Envelope C403.2.4.3 Air Leakage C402.5.6 Envelope Roof insulation installed per manufacturer2ETMs instructions. Blown or poured loose -fill insulation is installed only where the roof slope is —3 in 12. Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Fenestration products rated in accordance with NFRC. Fenestration products are certified as to performance labels or certificates provided. Floor insulation installed per manufacturer's instructions. Cavity or structural slab insulation installed in permanent contact with underside of decking or structural slabs. Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Non -swinging opaque doors have R-4.75 insulation. Skylight curbs are insulated to the level of roofs with insulation above deck or R-5. Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Building envelope contains a continuous air barrier that has been tested and deemed to limit air leakage — 0.40 ctm/ft2. The building envelope contains a continuous air barrier that is sealed in an approved manner and either constructed or tested in an approved manner. Air barrier penetrations are sealed in an approved manner. All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor -permeable wrapping material to minimize air leakage. The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability — 0.004 cfm/ft2. Air barrier penetrations are sealed in an approved manner. The building envelope contains a continuous air barrier that is sealed in an approved manner and average assembly air leakage — 0.04 cfm/ft2. Air barrier penetrations are sealed in an approved manner. Factory -built fenestration and doors are labeled as meeting air leakage requirements. Where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening are located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope Stair and elevator shaft vents have motorized dampers that automatically dose. Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Weatherseals installed on all loading dock cargo doors. EnergyGauge Summit® FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 11 of 21 Air Leakage C402.5.8 Envelope Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal interiorenfinishandluminairehousing. HVAC C403.2.1 Mechanical HVAC systemsandequipment design loads 13 El calculatedinaccordancewithANSI/ ASHRAE/ACCA Standard 183 or by an approved equivalent computational procedure SYSTEM — SPECIFIC C403.2.10 Mechanical HVAC piping insulation thickness. Where piping O D isinstalledinorunderaslab, verification may need to occur during Foundation Inspection. HVAC C403.2.3 Mechanical HVAC equipment efficiency verified. O SYSTEM SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. 13 labeled for replacement only as per Footnote b to Table C403.2.3(3). SYSTEM SPECIFIC C403.2.4.1 Mechanical Heating and cooling to each zone is controlled by D a thermostat control. Minimum one humidity control device per installed humidification/ dehumidification system. SYSTEM — SPECIFIC C403.2.4.1.1 Mechanical Heat pump controls prevent supplemental electric 13 resistance heat from coming on when not needed. HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 A'F deadband. 0 HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 A'F deadband. O 13 HVAC C403.2.4.1.3 Mechanical Temperature controls have setpoint overlap 13 13 restrictions. HVAC C403.2.4.2.1, Mechanical Automatic Controls: Setback to 55'F (heat) and C403. 2.4.2.2 85'F (cool); 7-day clock, 2-hour occupant override, 10-hour backup SYSTEM SPECIFIC C403.2.4.2.3 Mechanical Systems include optimum start controls. 0 HVAC C403.2.4.5, Mechanical Snowfice melting system sensors for future13 C403.2.4.6 connection to controls. Freeze protection systems have automatic controls installed. HVAC C403.2.6.2 Mechanical Enclosed parking garage ventilation has 13 automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. HVAC C403.2.9 Mechanical HVAC ducts and plenums insulated. Where ducts 13 13 or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. SYSTEM SPECIFIC C403.2.9.1.3 Mechanical Ductwork operating >3 in. water column requires 0 air leakage testing. SYSTEM SPECIFIC C403.4.1.2 Mechanical VAV fans have static pressure sensors located so 0 controller setpoint —1.2 w.c.. SYSTEM SPECIFIC C403.4.2.2 Mechanical Two -pipe hydronic systems using a common distribution system have controls to allow a deadband — I5°F, allow operation in one mode for at least 4 hrs before changeover, and have rest controls to limit heating and cooling supply temperature to —30 OF. SYSTEM SPECIFIC C403.4.2.3.3 Mechanical Two -position automatic valve interlocked to shut off water flow when hydronic heat pump with pumping system >10 hp is off. SYSTEM — SPECIFIC C403.4.4.5, Mechanical Zone controls can limit simultaneous heating and C403. 4.4.5.14 cooling and sequence heating and cooling to each zone. SYSTEM — SPECIFIC C403.4.5 Mechanical Condenser heat recovery system that can heat 13 13 0 water to 85OF or provide 60% of peak heat rejection is installed for preheating of service hot water. SYSTEM SPECIFIC C403.4.6 Mechanical Hot gas bypass limited to: 13 240 kBtu/h - 50% capacity, 240 kBtu/h - 25% capacity SYSTEM SPECIFIC C404.3 Mechanical Heat traps installed on non -circulating storage 0 water tanks. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/ 31 /2018 Page 12 of 21 SYSTEM —SPECIFIC C404.3 Mechanical Heat traps installed on supply and discharge O piping of non -circulating systems. SYSTEM —SPECIFIC C404.3 Mechanical Heat traps installed on supply and discharge piping of non -circulating systems. SYSTEM —SPECIFIC C404.6.1 Mechanical Controls are installed that limit the operation of a O 13recirculationpumpinstalledtomaintain temperature of a storage tank. System return pipe is a dedicated return pipe or a cold water supply SYSTEM —SPECIFIC C404.6.1, C404.6.2 pipe. lyMechanicalAutomatictimeswitchesinstalledtoautomatical switch off the recirculating hot-water system or heat trace. SYSTEM SPECIFIC C404.9.1 Mechanical Pool heaters are equipped with on/oft switch and no continuously burning pilot light. SYSTEM —SPECIFIC C404.9.2 Mechanical Time switches are installed on all pool heaters O and pumps. SYSTEM —SPECIFIC C404.9.2 Mechanical Time switches are installed on all pool heaters and pumps. SYSTEM —SPECIFIC C404.9.3 Mechanical Vapor retardant pool covers are provided for O heated pools and permanently installed spas. Controls C405.2.1 Interior Lighting Lighting controls installed to uniformly reduce the O lighting load by at least 50%. Controls C405.2.1 Interior Lighting Occupancy sensors installed in required spaces. 13 D D Controls C405.2.1, Interior Lighting Independent lighting controls installed per 13 O 13C405.2.2.3 approved lighting plans and all manual controls readily accessible and visible to occupants. Controls C405.2.2.1 Interior Lighting Automatic controls to shut off all building lighting installed in all buildings. Controls C405.2.3 Interior Lighting Daylight zones provided with individual controls that control the lights independent of general area lighting. Controls C405.2.3, Interior Lighting Primary sidelighted areas are equipped with DC405.2.3.1, required lighting controls. C405.2.3.2 Controls C405.2.3, Interior Lighting Enclosed spaces with daylight area under D O ElC405.2.3.1, skylights and rooftop monitors are equipped with C405.2.3.3 required lighting controls. Controls C405.2.4 Interior Lighting Separate lighting control devices for specific uses O 0installedperapprovedlightingplans. Wattage C405.2.4 Interior Lighting Additional interior lighting power allowed for 0 0specialfunctionspertheapprovedlightingplans and is automatically controlled and separated from general lighting. Controls C405.2.5 Exterior Lighting Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on business operation time -of -day, or reduce connected lighting > 30%. Wattage C405.4.1 Interior Lighting Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Mandatory Additional C406.4 Project Enhanced digital lighting controls efficiency 0 package: Interior lighting has following enhanced lighting controls in accordance with Section C405.2.2: Luminaires capable of continuous dimming and being addressed individually, — 8 luminaires controlled in Mandatory Additional C406.6 Project Dedicate outdoor air system efficiency package: D 13Buildingswithhydronicand/or multiple -zone HVAC systems are equipped with an independent ventilation system designed to provide >_ 100-percent outdoor air to each individual occupied space, as specified by EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31 /2018 Page 13 of 21 Mandatory Additional C406.7, C406.7.1 Project HVAC C408.2.2.1 Mechanical HVAC C408.2.2.1 Mechanical Testing C408.2.3.2 Mechanical Enhanced Service Water Heat System efficiency package. One of the following SWH system enhancements must satisfy 60 percent of hot water requirements, or 100 percent if the building otherwise complies with heat recovery per Section C403.4.5: Waste heat re Air outlets and zone terminal devices have means for air balancing. Air outlets and zone terminal devices have means for air balancing. HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. 4. To be checked by Inspector at Project Completion and Prior to Issuance of Certificate of Occup_.y Post Construction C303.3, C408.2.5.2 Interior Lighting Fumished O&M instructions for systems and equipment to the building owner or designated representative. Post Construction C303.3, C408.2.5.3 Mechanical Fumished O&M manuals for HVAC systems within 90 days of system acceptance. Fenestration C402.4.2.2 Envelope Skylights in office, storage, automotive service, manufacturing, non -refrigerated warehouse, retail store, and distribution/sorting area have a measured haze value > 90 percent unless designed to exclude direct sunlight. Post Construction C408.2.1 Mechanical Commissioning plan developed by registered design professional or approved agency. Post Construction C408.2.3.1 Mechanical HVAC equipment has been tested to ensure proper operation. Post Construction C408.2.3.3 Mechanical Economizers have been tested to ensure proper operation. Post Construction C408.2.4 Mechanical Preliminary commissioning report completed and certified by registered design professional or approved agency. Post Construction C408.2.5.1 Mechanical Furnished HVAC as -built drawings submitted within 90 days of system acceptance. Post Construction C408.2.5.1 Interior Lighting Fumished as -built drawings for electric power systems within 90 days of system acceptance. Post Construction C408.2.5.3 Mechanical An air and/or hydronic system balancing report is provided for HVAC systems. Post Construction C408.2.5.4 Mechanical Final commissioning report due to building owner within 90 days of receipt of certificate of Post Construction C408.3 Interior Lighting occupancy. Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 14 of21 Input Data Report Proiect Information Project Name: C0718349 Project Title: Smart Technologies of Florida Address: 3811 Caboose Place State: FL Zip: 32771 Owner: Smart Technologies of Florida Building Type: Office Building Classification: Renovation to existing building No.of Stories: 1 GrossArea (SF): 6,990 Bldg. Rotation: None Zones No Acronym Description Type Area Multi Total Area Isf) isn 1 Offices Offices CONDITIONED 1866.0 1 1866.0 2 Uncond Uncond Warehouse UNCONDITIONED 5124.0 1 5124.0 Warehouse Spaces No Acronym Description Type Depth Ift) Width IN Height Mult Ift) Total Area Total Vollcf) Isf) In Zone: Offices 1 Office Office Office - Enclosed 48.09 38.80 9.50 1 1866.0 17727.0 In Zone: Uncond Warehouse I Uncond Wareh, Uncond Warehouse Storage & Warehouse - Bulky 85.40 60.00 18.60 1 5124.0 95306.4 D Active Storage EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31 /2018 Page 15 of 21 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire W] Ctrl pts In Zone: Offices In Space: Office 1 Compact Fluorescent General Lighting 32 64 2048 Occupancy sensor without 1 Daylighting 2 Compact Fluorescent Exit Sign 3 5 15 Security (continuous) 1 In Zone: Uncond Warehouse In Space: Uncond Warehouse 1 Compact Fluorescent General Lighting 60 64 3840 Occupancy sensor without 4 Daylighting 2 Compact Fluorescent Exit Sign 2 5 10 Security (continuous) 1 Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H (Effec) Multi Area Orient Cond- Heat Dens. R-Value jft] Ift] plier Ist] ation uctance Capacity jib/cf] Ih.sEFBtu] Btu/h.sf.Fl [Btu/si F] In Zone: Offices 1 Block/Frame, R13 Metal 11.80 9.50 1 112.1 North 0.0920 1.072 19.38 10.9 siding/2x4@24"+R1 I Batt/5/8-Gyp 2 Block/Frame, R13 Metal 38.80 9.50 1 368.6 South 0.0920 1.072 19.38 10.9 siding/2x4@24"+Rl 1 Batt/5/8"Gyp 3 Block/Frame, R13 Metal 60.00 9.50 1 570.0 West 0.0920 1.072 19.38 10.9 siding/2x4@24"+R 1 1 Batt/5/8"Gyp 4 Frame, R13 Metal 60.00 9.50 1 570.0 East 0.0920 1.072 19.38 10.9 siding/2x4@24"+Rl 1 Batt/5/8"Gyp EnergyGauge Summit@ Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 16 of 21 Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area Btu/hr sf F] IN (ft) plier Isf] In Zone: ORces In Wall: E Wall 2 Low-e East No 1.2500 0.82 0.76 4.00 4.00 2 32.0 In Wall: N Wall 1 Low-e North No 1.2500 0.82 0.76 4.00 4.00 1 16.0 Doors No Description Type Shade? Width H (ERec) Multi Area Cond. Dens. Ht Cap. R ft) (ftl plier ]sf) ]Btu/h.sEF] ]Ib/cf) ]Btu/sE Ih.sf.F/ F) Btu] In Zone: Offices In Wall: E Wall 1 Door Solid core flush No 3.00 7.00 3 21.0 0.3504 0.00 0.00 2.85 2.25) Roofs No Description Type Width H (ERec) Multi Area Tilt Cond. Heat Cap Dens. R-Value jft] IN plier jst] [deg] [Btu/b.Sf. F] [Btu/sE F) jlb/cf] jh.sLFBtu In Zone: Offices 1 Metal, R19 Mtl Bldg RooDR-19 38.80 48.09 1 1866.0 0.00 0.0492 1.34 9.49 20.3 Batt EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 17 of 21 Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multi- Area Total Area Bru/hr sfF1 IN IN prier ISf] i$fj In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value Ift) Ift1 plier 1sf1 [Btu/h.sEF (Btu/sE F) alb/cf1 (h.sEF/Btu Zone: Offices 1 Floor 1 fl. soil, concrete 38.80 48.09 1 1866.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad Systems A.HU1 AHU1 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units I Component Category Capacity Efficiency IPLV 1 2 3 4 Cooling System Heating System Air Handling System -Supply Air Handling System - Return 57000.00 14.00 8.00 54500.00 8.20 1900.00 0.00 1900.00 0.00 EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31 /2018 Page 18 of 21 Plant Equipment Category Size Inst.NcEff. IPLV Water Heaters W-Heater Description Capacity Cap.Unit UP Rt. Efficiency Loss 1 Electric water heater 20 [Gal] [kW] 0.9700 [Ef] Btu/h] Ext-Lighting Description Category No. of Watts per Lumin- Lumin- aires aire Area/Len/No sUft/No) Control Type Wattage W) Piping No Type Operating Insulation Temp Conductivity IF] [ Btu-in/h.sf.F] Nomonal pipe Diameter in] Insulation Thickness in] Is Runout? Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance Btu/h.sf.F) ASHULSgICIrAII User Defined Frm 1 1.2500 0.8200 0.7600 EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 19 of 21 Materials Used Mat No Acronym Description Only RValue Thick Cond- Density Sp. Heat R-Value h.sf.FBtul ift] uctivity Ib/cf) Btu/1b.F] Used l Btu/h.ft.F 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0,2000 0 BOARD,I/21N 178 Matl178 CARPET W/RUBBER PAD Yes 1.2300 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 4 Matl4 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 271 Matl271 2x4@24" oc + RI I Batt No 10.4179 0.2917 0.0280 7.11 0.2000 279 Mat1279 Solid core flush (2.25") Yes 2.8537 94 Matl94 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 EnergyGauge Summit® FlalCom-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31/2018 Page 20 of 21 Constructs Used No Name Simple Massless Conductance Heat Cap Density RValue Construct Construct Btu/h.sEFI [Btu/sEF] lb/cf] lh.sf.FBtu) 1019 Metal No No 0.09 1.07 19.38 10.9 siding/2x4@24"+R 11 Batt/5/8"Gyp Layer Material Material Thickness Framing No. Ift] Factor 1 4 Steel siding 0.0050 0.000 2 271 2x4 a( 24" oc + RI I Batt 0.2917 0.000 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 No Name Simple Massless Conductance Heat Cap Density RValue Construct Construct Btu/h.sf.Fl lBtu/sEF] Ilb/cn Ih.sf.FBtu) 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 Layer Material Material Thickness Framing No. N Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 2 23 6 in. Insulation 0.5000 0.000 No Name Simple Massless Conductance Heat Cap Density RValue Construct Construct IBtu/h.sEF] lBtu/sf.F) Ilb/cf) Ih.sEFBtul 1057 1 ft. soil, concrete floor, carpet and No No 0.27 34.00 113.33 3.7 rubber pad Layer Material Material Thickness Framing No. ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 No Name Simple Massless Conductance Heat Cap Density RValue Construct Construct IBtu/h.sEFI IBtu/sf.Fl Ilb/cf) Ih.sf.FBtu) 1058 Solid core flush (2.25) No Yes 0.35 2.9 Layer Material Material Thickness Framing No. IN Factor 1 279 Solid core flush (2.25") 0.000 EnergyGauge Summit® Fla/Com-2017. TAM 2017-1.0 Compliant Software. Effective Date: Dec 31, 2017 Florida Building Code, Sixth Edition (2017) - Energy Conservation IECC 2015 - Total Building Performance Compliance Option 7/31 /2018 Page 21 of 21 4 wrightsofr Right -Suite® Universal 2018 Short Form AHU1- Vices JHR Consultants- Inc PERMIT #_ 1K- -7W_..,, 312 Forest Ae, Ntamorte Sprarps, FL 32701 Phore: 407-262.9176 roject Intormation For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 Job: C0318163 Date: 07-20-16 By. MKC ICE, Htg Clg Htg Clg Outside db OF) 41 92 Inside db (OF) 70 75 Outside RH 45 Inside RH (%) 50 Outside wb OF) 75 Inside wb (OF) 63 Daily range OF) 17 Design TD (OF) 29 17 Moisture diif. gr/Ib) 39 Heating Equipment Cooling Equipment Make 5 ton - Carrier or Eqv. Make 5 ton - Carrier or Eqv. Model 25HCE460 Model 25HCE460 Type SplitASHP Type SplitASHP Efficiency 8.2 HSPF COP / EER / SEER 14.0 Heating Input Sensible Cooling 42.8 MBtuh Heating Output 54.5 MBtuh @ 47°F Latent Cooling 14.3 MBtuh Humidifier 12.7 gpd Total Cooling 57.0 MBtuh L. eavingAirTemp 70.0 OF L.eavingAirTemp 55.0 OF Actual Heating Fan 0 ctm Actual Cooling Fan 1900 cfm Equipment Location AHU1- Offices System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency 0 Static Pressure Across Fan 0 in H2O NAME Area fe Heat Loss Sensible Gain Latent Gain Htg ctm Clg ctm Time PropOffice 152 4399 3827 1030 0 189 Jul 1700 LDT PropConference 277 4926 4906 1891 0 233 Jul 1700 LDT Hall l 54 627 870 132 0 44 Jul 1700 LDT PropHelpDesk 183 2032 3761 1437 0 177 Jul 1700 LDT AHU 15 30 31 12 0 2 Jul 1700 LDT PropOfficel 99 905 2159 903 0 101 Jul 1700 LDT ProplTOffice 103 922 2182 912 0 102 Jul 1700 LDT PropKitdienette 121 1824 3804 482 0 191 Jul 1700 LDT PropO( 6ce2 96 893 2143 896 0 100 Jul 1700 LDT PropOffice3 93 1446 2665 888 0 130 Jul 1700 LDT PropSetUp 177 5602 3812 1370 0 185 Jul 1700 LDT PropSalesOfrce 352 10375 7240 2630 0 355 Jul 1700 LDT Nall 1A,, 7 1QCn owc n n4 1..1 4 ^ftI M wrightsoft- 2018-JJ-311301:18 laght- Sate®LNivemW 201818.0.19 RSUD9290 Pepe t e 7-17.18 - C07I eU9 - Sm01 TedK=718349n9 CaIC - W4 Buldirg Frod faces: N AHU7 - Offims I _j1W534647139250112930101900Jul1700LDT wrightsoft- 2018-,Ai-31 13A1:18 w•,r.....u. 1ap11-SUIst lkivemal 201818.0.19 RSU09280 Pepe 2 e7-17-18-00718349-SrroiTedYC00718349np Celt-WM BuldirgFrortfaces N Right -Suite® Universal 2018 Load Summary .rob: C0318163 wrightsoft Dais: 07-20-18 AHU1 -Vices By. MKC JHR Consultants, Inc 312 Forest Ae. Altamorte SDnrgs, FL 32701 Phone, 407-262-9176 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 R-one: 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoistDiif 38.7 gdlb Mult 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 515 3. TRANSMISSION GAINS Sensible 6354 Walls. 2298 Glass: 488 Doors. 662 Partitions: 0 Floors: 0 Ceilings: 2905 4. INTERNAL HEAT GAIN Sensible Latent 18076 4425 Occupants: 5059 4425 Lights: 8145 Motors: 0 Appliances: 4872 0 5. INFILTRATION: Outside air cfm: 40 775 1060 6. SUBTOTAL- Space load Sensible Latent 25718 5485 Envelope 25718 5485 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 6201 SUBTOTAL: Space load + supply duct 31919 Actual ctm: 1900 at supply TD: 20 9. VENTH.ATION: Make-up air cfm: 223 4287 5865 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 3044 12. TOTAL LOADS ON EQUIPMENT 39250 12930 MOWS&.HF TING LOAD 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 10895 Walls: 4138 Glass: 902 Doors: 642 Partitions: 0 Floors: 2446 Ceilings: 2767 15. UNFII.TRATION: Outside air ctm: 175 5581 16. SUBTOTAL: Space load 16476 Envelope 16476 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 5208 1& VE1NTH ATION: Make-up air cfm: 223 7131 19. HUMIDIFICATION 4815 Piping 0 20. RETURN DUCT 1016 21. TOTAL HEATING LOAD ON EQUIPMENT 34647 Fla- wrightsoft- 2018-AS-31 1301:18 MgMSate Liri%ersa1201818.0.19 RSL=290 Page 1 e7-17-18-00718349-SmmnTedIC00718349Ap CalcaW6 BuldirpFrortfaces: N Right -Suited Universal 2018 Load Summary Jab: C0316163 wrightsofC A'/!J Bate: 07- MKC 18 Y JHR Consultants, Inc 312 Forest Are. Almmorse Spr1r9s. FL 32701 Phore:407-262-9176 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 B20ne: AHU'i=''„',»3i,<',. COO"LIWG LOAD ' ` rK. I. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 2100 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RK 45 % MoistDifE 38.7 grAb Mult 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 3. TRANSMISSION GAINS Sensible 23 Walls. 0 Glass. 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings. 23 4. INTERNALHEAT GAIN Sensible Latent 0 0 Occupants: 0 0 Lights: 0 Motors: 0 Appliances: 0 0 5. INFILTRATION: Outside air ctm: 0 0 0 6. SUBTOTAL- Space load Sensible Latent 23 0 Envelope 23 0 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 6 SUBTOTAL: Space load + supply dud 28 Actual cfm: 2 at supply TD: 20 9. VEN7TLATION: Make-up air cfm: 0 0 0 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 3 12. TOTAL LOADS ON EQUIPMENT 31 12 4 ;`",:.HEATING LOAD. 13. DESIGN CONDMONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 22 Walls: 0 Glass. 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings. 22 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 22 Envelope 22 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT- 7 1& VEN71IATION: Make-up air dm: 0 0 19. HUMIDIRCATION 0 Piping 0 20. RETURN DUCT 1 21. TOTAL HEATING LOAD ON EQUIPMENT 30 wrlghtSpft- 2018-Ai-31 1301:18 Right-Sute91.1riversal201818.0.19RSLD9280 Pepe 2 e 7-17-18 - C0718349 - Smart Ted1C00718349np Cale- W6 BUldir9 FrM faces: N Right -Suite® Universal 2018 Load Summary .rob: C0318163 wrightsofte Hall Bate: MKC 18 r JHR Consultants, Inc 312 Ford Ave. Allamorte Sprirps, FL 32701 Phone: 407-282-9176 Project• • For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 1. DESIGN CONDITIONS at Jul 1700 LDT Inside: 75 OF Outside: 92 OF RH: 45 % MoislDifF 38.7 grAb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls. 0 Glass: 0 Doors. 0 Partitions: 0 Floors: 0 Ceilings: 222 4. INTERNALHEAT GAIN Sensible Occupants: 0 Lights: 1018 Motors: 0 Appliances: 0 5. ROMTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 1240 Less external 0 Redistribution 0 7. SUPPLY DUCT SUBTOTAL: Space load + supply duct Actual cfm: 91 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT Peak load at Jul 1700 LDT TD: 17 OF Mult 1.0 Inswb 63 OF Sensible Latent 0 - 222 - HEATINGOAD Latent 1018 0 0 0 0 0 0 Latent 1240 0 0 0 299 1539 20 9 164 224 0 147 1850 345 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 211 Walls. 0 Glass. 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings. 211 15. INFILTRATION: Outside air cfin: 0 0 16. SUBTOTAL: Space load 211 Envelope 211 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT- 67 1& VENTI.ATION: Make-up airdm: 9 273 19. HUMIIDTHCATION 103 Piping 0 20. RETURN DUCT 13 21. TOHEATING LOAD ON EQUIPMENT 667 wrlghtsoft- 201841.31 13D1:18 fth-SU00t.1riversal 201818.0.19 RSUD9290 Page 3 a7-17-18-00718349- Smart Ted1000718349Ap Cate -W6 BU1doVFror4faces: N Right -Suite® Universal 2018 Load Summary Job: C0316163 wrightsoft' Dale: 0720.18 HaD1 By- MKC JHR Consultants, Inc 312 Forest Are, AJt3mate Sprirpa, FL 32701 Plore: 407.262.9176 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 fZone: H. 511,1 ; { 1- WRAL NOW.COOLING LOAD 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoistDit 38.7 gr/lb Mult 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 3. TRANSMISSION GAINS Sensible 339 Walls: 33 Glass: 0 Doors: 221 Partitions: 0 Floors: 0 Ceilings. 85 4. INTERNAL HEAT GAIN Sensible Latent 255 0 Occupants: 0 0 Lights: 255 Motors: 0 Appliances: 0 0 5. DYFI.TRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 594 0 Envelope 594 0 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 143 SUBTOTAL: Space load + supply dud 737 Actual cfm: 44 at supply TD: 20 9. VENTILATION: Make-up air dm: 3 63 86 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 70 1 L TOTAL LOADS ON EQUIPMENT 870 132 HEATING LOAb 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 350 Walls: 56 Glass: 0 Doors: 214 Partitions: 0 Floors: 0 Ceilings: 81 15. DOMTRATION: Outside air ctm: 0 0 16. SUBTOTAL: Space load 350 Envelope 350 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT- I I I l8. VENTILATION: Make-up air dm: 3 104 19. HUMIDI7CATION 40 Piping 0 20. RETURN DUCT 22 21. TOTALHEATDVG LOAD ON EQUIPMENT 627 wrightsoft- 201841-31 13,01.18 Pigti-SUtO U iversal 201818.0.19 RSU09290 Page 4 e 7-17-18- C0718349- SmaA Teri =718349jW Cale- MN5 Stildirg Fmrt races: N Right -Suite® Universal 2018 Load Summary Jon: C0318163 wrightsofto Data: 07-20-18 PropConfe ence By. MKC JHR Consultants, Inc 312 Forest Ae. Alt m ase Springs, FL 32701 Pl im 407-262-9176 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 i 25% Prr pCorHe'ce"';.1)" COOLING' LOAD r ' " 1. DESIGN CONDITIONS at Jul 1700 LDT Inside: 75 OF Outside: 92 OF RH: 45 % MoistDit 38.7 gdlb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls. 298 Glass. 0 Doors. 0 Partitions: 0 Floors: 0 Ceilings: 432 4. INTERNALHEATGAIN Sensible Occupants: 784 Lights: 1018 Motors: 0 Appliances: 629 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 3162 Less external 0 Redistribution 0 7. SUPPLY DUCT SUBTOTAL: Space load + supply dud Actual cfm: 233 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT Peak load at Jul 1700 LDT TD: 17 OF Mult 1.0 Ins.wb 63 OF Sensible Latent 0 - 730 - Latent 2431 825 825 0 0 0 0 Latent 3162 825 825 0 762 3924 20 32 608 831 0 374 4906 1891 J .t }"5. s•r!'J• 'T: ,t h_ 1 .^_. liV *' S 4 !.' J 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 1469 Walls: 558 Glass: 0 Doors: 0 Partitions: 0 Floors: 499 Ceilings. 412 15. INMTRATION: Outside air cfm: 27 859 16. SUBTOTAL: Spao load 2328 Envelope 2328 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT- 736 1& VENTILATION: Make-up air dm: 32 1011 19. HUMIDIFICATION 708 Piping 0 20. RETURN DUCT 143 21. TOTAL HEATING LOAD ON EQUIPMENT 4926 wrlghtSotFt` 2018-,AS-31 1301:18 18pt1-SUte®Uri%ersal 201818 0.19 RS1A9290 Pape 5 e7-17-18-00718349- Smart TedAC0071&UltAp Celc=WS BuldirgFrortfaces: N Right -Suite® Universal 2018 Load Summary Job: C0318163 wright.Soft' 18 PropHelpDesk By. MKC JHR Consultants, Inc 312 Forest Aye. Almmmte Sprtrgs. FL 32701 Rim : 407-262-9176 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 Zone: PropH0 sk, c , :3r; 'COOLING 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoistDiff 38.7 grAb Mult 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 3. TRANSMISSION GAINS Sensible 509 Walls. 224 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 285 4. INTERNALHEAT GAIN Sensible Latent 1891 600 Occupants: 713 600 Ligw. 764 Motors: 0 Appliances: 415 0 5. INFILTRATION: Outside air dm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 2400 600 Envelope 2400 600 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 579 8. SUBTOTAL: Space load + supply duct 2979 Actual cfm: 177 at supply TD: 20 9. VENTILATION: Make-up air dm: 26 499 682 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 284 12. TOTAL LOADS ON EQUIPMENT 3761 1437 MEATING 11 DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 645 Walls: 373 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 271 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Spaceload 645 Envelope 645 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT. 204 l& VENTILATION: Make-up air dm: 26 830 19. HUMIDIFICATION 314 Piping 0 20. RETURN DUCT 40 21. TOTALHEAT NG LOAD ON EQUIPMENT 2032 Lmt tsol f- MpMSuie®Uriversa1201818.0.19RS1A9290 201841- 31130118 Pape 8 a7. 17.18-00718349- Smart Ted1C00718349Av Calc=MNS SUldirgFrorifaces: N Right -Suite® Universal 2018 Load Summary Job: C0318163 wright5oft' proplT ce By. MKC 18 JHR Consultants, Inc 312 Forest P e. Albmate Sprlrge. FL 32701 Ptore: 407.282.9176 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL32771 Zone: ProplTzQlfice;COOLING LOAD`°'> "" i. 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoislDilf: 38.7 grAb Mult 1.0 Inswb 63 OF Sensible Latent 2. SOLAR RADIATION TFIROUGA GLASS 0 3. TRANSMISSION GAINS Sensible 160 Walls. 0 Glass. 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 160 4. EVTERNAL HEAT GAIN Sensible Latent 1217 400 Occupants. 475 400 Lights: 509 Motors: 0 Appliances: 233 0 5. INFILTRATION: Outside air dm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 1377 400 Envelope 1377 400 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 332 SUBTOTAL: Space load + supply dud 1709 Actual cfm: 102 at supply TD: 20 9. VENTILATION: Make-up air dm: 16 310 425 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 163 12. TOTAL LOADS ON EQUIPMENT 2182 912 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 152 Walls: 0 Glass: 0 Doors. 0 Partitions: 0 Floors: 0 Ceilings: 152 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 152 Envelope 152 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT. 48 1& VENTILATION: Make-up air dm: 16 516 19. AUMIIDMCATION 196 Piping 0 20. RETURN DUCT 9 21. TOTALHEATIVG LOAD ON EQUIPMENT 922 wrightsoft• 2018-,A1•31 13A1:18 ISgMSUte®Uriveraal201818.0.19RSLO9290 Pape 7 e7-17-18-00718U9- Smart Tea K=718349np Calc=PANS SUldirgFrortfaces: N wright.Soft' Right -Suite® Universal 2018 Load Summary Job: C0318163 Propl itchenette By MKC 18 JHR Consultants, Inc 312 Forest Am. Arena Is Sprirgs, FL 32701 Phore: 407-282-9178 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 KZone Popl,"Gtcnenerie . ! L%. cWCf d 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoistDit 38.7 grAb Mult 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 3. TRANSMISSION GAINS Sensible 690 Walls: 282 Glass: 0 Doors: 221 Partitions: 0 Floors: 0 Ceilings: 188 4. INTERNALHEAT GAIN Sensible Latent 1904 0 Occupants. 0 0 Lights: 509 Motors: 0 Appliances: 1395 0 5. INFILTRATION: Outside air cfm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 2594 0 Flrvelope 2594 0 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 625 8. SUBTOTAL: Space load + supply duct 3219 Actual dm: 191 at supply TD: 20 9. VENTILATION: Make-up air cfm: 14 278 380 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 307 12. TOTAL LOADS ON EQUIPMENT 3804 482 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 862 Walls: 469 Glass: 0 Doors: 214 Partitions: 0 Floors: 0 Ceilings: 179 15. U4MTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 862 Flrvelope 862 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 272 I& VENTILATION: Make-up air dm: 14 462 19. HUMIDIFICATION 175 Piping 0 20. 21. TbOTALLHEATING LOAD ON EQUIPMENT 1824 wrlghtsolR- 201841-3113A1:18 FboMStiWOUrnersel201818.0.19FtSU09290 Page e7-17-18-00718349-SmanTed1C00718U9np Celc-MNS SUldirpFrortfeoea N Right -Suite® Universal 2018 Load Summary Job: C0318163 wright5oft' Pmp ce sY - MKco-18 JHR Consultants, Inc 312 Forest Ae, AiMmorte Spdrpa, FL 32701 Phow 407-262-9176 Project• • For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 1. DESIGN CONDITIONS at Jul 1700 LDT Inside: 75 OF Outside: 92 OF RH: 45 % MoistDitt 38.7 grAb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 308 Glass: 327 Doors: 0 Partitions: 0 Floors: 0 Ceilings., 236 4. INTERNALHEATGAIN Sensible Occupants: 475 Lights: 509 Motors: 0 Appliances: 344 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Spaceload Sensible Envelope 2545 Less external 0 Redistribution 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply dud Actual cfm: 189 at supply TD: 9. VENTILATION: Make-up air dm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT HEATINq. EoPeak load at Jul 1600 LDT TD: 17 OF Mult 1.0 Ins.wb Sensible 345 872 Latent 400 0 0 Latent 400 0 20 19 1328 0 2545 614 3159 367 0 301 3827 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 1752 Walls. 586 Glass: 605 Doors: 0 Partitions: 0 Floors: 336 Ceilings: 225 I& INFILTRATION: Outside air cfm: 20 651 16. SUBTOTAL: Space load 2403 Envelope 2403 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT 760 1& VENTIIATTON: Make-up airdm: 19 610 19. HUMIDIFICATION 478 Piping 0 20. RETURN DUCT 148 21. TOTALHEATING LOAD ON EQUIPMENT 4399 63 OF Latent 400 0 400 502 1030 w t IghtS,0 - 2018-,Al-311301:18 ftM- SUte®Uiuersal 201818.0.19 RSU09290 Pepe 9 e7- 17.18-00718349-SmarlTeolh=718349np Cale-O&Z BUldirgFrorlraces: N Right -Suite® Universal 2018 Load Summary Job: C0318163 wrightsofte Date: 07 20-18 PropOfficel By- MKC JHR Consultants, Inc 312 Forest Ave. Ahamorle Sprirgs. FL 32701 Phone:407-262-9178 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 EZone: P-WOQlfael '^COOLING'.LOAD :'xuaa.. 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoistDiff 38.7 gdlb Mult 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 3. TRANSMISSION GAINS Sensible 154 Walls: 0 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 154 4. INTERNAL HEAT GAIN Sensible Latent 1209 400 Occupants: 475 400 Lights: 509 Motors: 0 Appliances: 225 0 5. INMTRATION: Outside air c1m: 0 0 0 6. SUBTOTAL: Spaos load Sensible Latent 1363 400 Envelope 1363 400 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 329 SUBTOTAL: Space load + supply dud 1692 Actual dm: 101 at supply TD: 20 9. VENTILATION: Make-up air cfm: 16 306 419 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 161 12. TOTAL LOADS ON EQUIPMENT 2159 903 HEATING, LOAD., jail 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 147 Walls: 0 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings. 147 15. INFILTRATION: Outside air ctm: 0 0 16. SUBTOTAL: Space load 147 Envelope 147 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 46 1& VENTILATION: Make-up airdm: 16 509 19. AUMIDI RCATION 193 Piping 0 20. RETURN DUCT 9 21. TOTALAEATING LOAD ON EQUIPMENT 905 wrlghtS 4M- FdQ SU l 2018 /8.0.19 RSU09290 2018 M431 Page 1 Pepe 10 e7.17-18-00718349-SnwlTeo1AC00718349np Cate aW45 BuldirgFrortfaces: N Right -Suite® Universal 2018 Load Summary Job: C0318163 wrightSoft' 18 PiopWkQ By. MKC JHR Consultants, Inc 312 Forest Ave. Aibmxde Springs. FL 32701 Phore: 407-262.9176 Project• • For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL32771 FZone: Wp-0ffie2 1. DESIGN CONDITIONS at Jul 1700 LDT Inside: 75 OF Outside: 92 OF RK 45 % MoistDitt 38.7 grRb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls. 0 Glass. 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings. 150 4. UVTERNALHEAT GAIN Sensible Occupants: 475 Lights: 509 Motors: 0 Appliances: 219 5. INFILTRATION: Outside air ctm: 6. SUBTOTAL: Space load Sensible Envelope 1353 Less external 0 Redistribution 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply dud Actual dm: 100 at supply TD: 9. VENTILATION: Make-up air dm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTALLOADS ON EQUIPMENT Peak load at Jul 1700 LDT TD: 17 OF Mult 1.0 Ins.wb 63 OF Sensible Latent 0 - 150 - Latent 1203 400 400 0 0 0 0 Latent 1353 400 400 0 326 1679 20 16 303 415 0 160 2143 896 i - -S; ; ' 'a,r+pY+.. - 'i'. • .s , .cl{i. •M,`-: '{.-"'r::,1: 5: _-;„ v ,`, S 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 143 Walls. 0 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 143 15. INFILTRATION: Outside air cfm: 0 0 16. SUBTOTAL. Space load 143 Envelope 143 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT. 45 I& VENTILATION: Make-up air cfiifl: 16 504 19. HUMIDIFICATION 191 Piping 0 20. RETURN DUCT 9 21. TOTAL HEATING LOAD ON EQUIPMENT 893 Pp- wrightsoft- 2018-,A1.311301:18 Ripli-SUt*U iversal201818.0.19 RSUD9290 Pape 11 e7-17-18-00718U9-SmartTedt=718U9AV Celc-MM SUldirgFratfaoes: N Right -Suite® Universal 2018 Load Summary Job: C0318163 wrightsoft' PmpOffkO ey MKco-1e JHR Consultants, Inc 312 Forest A*, Alta morfa Sprfrps, FL 32701 Phore: 407-262.9176 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 IZone: Pno'"p_Of 1M3 0kWW: ,1`'a„ 'COOLING'LOi4D i"c 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1600 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoislDifF. 38.7 grAb Mult 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 169 3. TRANSMISSION GAINS Sensible 376 Walls: 71 Glass: 160 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 145 4. U4TERNALF FATGAIN Sensible Latent 1195 400 Occupants: 475 400 Lights: 509 Motors: 0 Appliances: 211 0 5. INFTLTRATION: Outside air dm: 0 0 0 6. SUBTOTAL: Space load Sensible Latent 1740 400 Envelope 1740 400 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 420 8. SUBTOTAL: Space load + supply dud 2160 Actual c1rn: 130 at supply TD: 20 9. VENTILATION: Make-up air dm: 16 299 409 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 206 12. TOTALLOADS ON EQUIPMENT 2665 888 iHEATING LOAD':' 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 552 Walls. 117 Glass. 296 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 138 15. INMTRATION: Outside air cfm: 0 0 16. SUBTOTAL: Space load 552 Envelope 552 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT- 174 1& VENTILATION: Make-up air dm: 16 498 19. HUMIDIFICATION 189 Piping 0 20. RETURN DUCT 34 21. TOTALHEATING LOAD ON EQUIPMENT 1446 wright soft- 2018-.A1.31 13A1:18 PoOn-Sdte®Uriversal 201818.0.19 RSLW290 page 12 e 7-17-18- 00718349- Srrart Too OW718349.np Calc- PAM Brfldirp Frorl faces: N Right -Suite® Universal 2018 Load Summary Job: C0318163 wrightsoft Date: 07 20-18 PmpSalesofflce By- MKC JHR Consultants, Inc 312 Forest Ave, Altamonte Sprirgs, FL 32701 Phore: 407-262-9176 For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL 32771 UZone: PropSa`( sOtfi xM ' VA'WdGW WAD" 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoislDiff 38.7 gdlb Mult 1.0 Ins.wb 63 OF Sensible latent 2. SOLAR RADIATION THROUGH GLASS 0 3. TRANSMISSION GAINS Sensible 1204 Walls: 655 Glass: 0 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 549 4. INTERNAL HEAT GAIN Sensible Latent 3039 600 Occupants: 713 600 Lights: 1527 Motors: 0 Appliances: 800 0 5. INFMTRATION: Outside air cfm: 30 571 782 6. SUBTOTAL: Space load Sensible Latent 4815 1382 Envelope 4815 1382 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 1161 SUBTOTAL: Space load + supply dud 5976 Actual cfm: 355 at supply TD: 20 9. VENTILATION: Make-up air cfm: 36 694 950 1& RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 570 12. TOTAL LOADS ON EQUIPMENT 7240 2630 I 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 2820 Walls: 1213 Glass: 0 Doors: 0 Partitions: 0 Floors: 1084 Ceilings: 523 15. INMTRATION: Outside air cfm: 87 2788 16. SUBTOTAL: Space load 5608 Envelope 5608 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT 1773 I& VENTILATION: Make-up airdm: 36 1155 19. HUMIDIFICATION 1493 Piping 0 20. RETURN DUCT 346 21. TOTAL HEATING LOAD ON EQUIPMENT 10375 wrlg~ Ripti-SateOUriversa1201818.0.19 RP SLID9290 2018AL31 age 13 Pepe 13e7- 17.18 - C0718349 - Smart Tedi000718U9nq Celc- bNr5 BUI&V Frort taoax N Right -Suite® Universal 2018 Load Summary Job: C0318163 wrightsoft' P/ SetU Date: 07.20-18 P P By. MKC JHR Consultants, Inc 312 Forest Ae, Allamorle Sprirgs. FL 32701 Phone: 407-262.9176 Zone: PropSetUp Froject Intormation For. Smart Technologies of Florida 3811 Caboose Place Warehouse (Lot 10), Sanford, FL32771 COOLING LOAD 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 OF Outside: 92 OF TD: 17 OF RH: 45 % MoistDitf 38.7 grAb Mult 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 3. TRANSMISSION GAINS Sensible 924 Walls: 427 Glass: 0 Doors: 221 Partitions: 0 Floors: 0 Ceilings: 276 4. INTERNALHEAT GAIN Sensible Latent 1386 400 Occupants: 475 400 Lights: 509 Motors: 0 Appliances: 402 0 5. INFILTRATION: Outside air cfm: 11 203 278 6. SUBTOTAL: Spaceload Sensible Latent 2513 678 Envelope 2513 678 Less external 0 Redistribution 0 0 7. SUPPLY DUCT 606 SUBTOTAL: Space load + supply dud 3119 Actual cfm: 185 at supply TD: 20 9. VENTILATION: Make-up air dm: 21 396 542 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 297 12. TOTAL LOADS ON EQUENENT 3812 1370 HEATING LOAD 13. DESIGN CONDITIONS Mult 1.0 Inside: 70 OF Outside: 41 OF TD: 29 OF 14. TRANSMISSION LOSSES 1770 Walls: 765 Glass. 0 Doors. 214 Partitions: 0 Floors: 528 Ceilings: 263 15. V011TRATION: Outside air dm: 40 1284 16. SUBTOTAL: Spaceload 3054 Envelope 3054 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 965 1& VENTILATION: Make-up air dm: 21 659 19. HUMIDIFICATION 736 Piping 0 20. RETURN DUCT 188 21. TOTALHEATING LOAD ON EQUIPIENT 5602 wrightsoft• 20184 F>ipht• Snite®Urirersal 201818.0.19 RSU09290 e7-17- 18-00718349-SmarlTeo'K=718349np Calc-106 SUldirgFrortfaces: N oe. se 45 0 1076 Grant Maio Clerk Of The Circuit Court 8 Comptroller Seminole County, FL Inst #201466959 Book:9197 Page:388; (1 PAGES) RCD: 8/22/2018 11:25:48 AM REC FEE $10.00 CERT'. I COPY GRANT MALOY Y NTHISame: NSG7RUM boP REPARF.D 6Y: CLE X OF THr C'. _UI I COURT AN I COiVd'', .ER Address: _ 1101 S181110V Ltmnwood. FL 32750 SEti,'n:r.E C U JTY, BYNOTICEOFCOMMENCEMENTDate State of Florida County of Seminole Permit Number. 18-3411 Parcel ID Number. 21-19-30-5SW 0000-0010 The undersigned hereby gives notice that improvement will be made to certain real property, and In accordance with Chapter 713. Florida Statutes, the following Information is provided In this Notice of Commencement DESCRIPTION OF PROPERTY: (Legal description of the properly and street address if available) 3811 Caboose Place. San -ford -FL 32771 GENERAL DESCRIPTION OF IMPROVEMENT: Office Addition OWNER INFORMATION: Name:_ Bolder Properties, LLC Address: 1740 SE 18th Street, Ocala FL 34471 Fee Simple Title Holder Of other than owner) Name: Address: CONTRACTOR: Name: wood Knot Construction Co. LLC Address: 1191 Stanley Street, Longwood FL 32750 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Address: In addition to himself, Owner Designates of To receive a copy of the L ienors Notice as Provided In Section 713.13(1)(b). Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is 1 year from date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE- OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury,) declare that I have read the foregoing and that the facts stated in It are true to the best of my knowledge and belief. Owners Signature OwnsPrinted Name Flodds Statute 713.13(1)(g): • The owner must sign the notice of cornnbneement and no one etas may be permitted to sign In his or her stead.' State of DY(GJ[ k County of 114 11 LI Q The foregoing Instru nt was acknowledged before me this ...lam_ day ofd G+L,4- by Who Is personally known to me Narne or person makbrg statement OR who has produced identification type of Identification produced: INiNEC.MWMW DIPIRE& OoED0ar24,1 t Nolary Signak" tlOrldEd iMYNpolyPlmBOIMdlIr11MA