Loading...
HomeMy WebLinkAbout1700 OLD ENGLAND LOOP (A) 01-000117 (2)ROOM FIN15H 5GHEOULE O MARK FLOOR BASE WALL CEILING NOTES REMARKS W H HD J SILL W W p I 4'-0" 5'-0" b,q 86 6'a 5%' 6'-8" Lu OL BIt If2 3'-b(2) 5'-0 b,a g b b,q 5 0 WLu 5GL. GLAZING gill 1 W v OLw z ca L, Lu o � o Lu � - r� ov> oorz U M NAME 12345 1 2345 12345 1 23 z i W C> DINING 3 2 1 � u 21 1 2 8'-D" VARIES AT TOP FLR UNITS MASTER BEDROOM 3 2 M 2 2 8'-0" W WIG #1 3 2 w `` 'a N 2 2 8'-p" (8/'-p" Lu � BEDROOM 2 3 2 F- 2 WIC #2 131 2 2 2 &'-p, BEDROOM 3 151 1 2 2 1 1 12 &'-0" WIG #3 51 1 2 2 12 8'-0" LIVING RM 31 1 21 1 2 2 &'-0" VARIES AT TOP FLR UMTS BATH 1 2 21 1 1 2 3* 1 &'-0" TUB SURROUND BATH 2 2 21 2 3* 1 T-0" *@ TUB SURROUND KITCHEN 2 2 2 1 &'-0" VARIES AT TOP FLR UNITS UTILITY 2 2 > w 2 LAUNDRY 2 2 2 2 7'-I" ENTRY 2 2 2 8'-0" VARIES AT TOP FLR UNITS .00M FINISH NOTES: INTERIOR WALL FINISHES: ALL INTERIOR WALL FINISHED TO BE FLAT LATEX ENAMEL EXCEPT WHERE NOTED OTHERWISE. SEE FINISH 5GHEDULE, APARTMENT FIN15H RATING: ALL FINISHES SHALL BE CLASS "B" FOR EXIT ACCESS AND "G" FOR ALL OTHER SPACES. 24"x30" MIRROF 24" TOWEL 36" X VANI CAE31N 0 SHOWER CURTAIN ROD 24"x30" MIRROR— LIGHT--\ I TONEL BAR T.P.H. 30" 211/2" 0" 36" 8'-q 1/2" FIN15H TO FINISH E3ATH #2 ELEVATIONS FURDOWN CEILING 24" TOWEL BAR FINISH TO FIN15H r_,***�BATH #1 ELEVATION5 36"x21" VANITY CABINET NOTES: I. ALL GROUND FLOOR UNITS SHALL MEET ALL CODES, LAN5 & GUIDELINES FOR HANDICAP AGGE551BILITY. LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS WITH OPERABLE PARTS ARE TO BE LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE FLOOR. 2. UNDER GUT ALL BEDROOM DOORS 1/2" ABOVE CARPET FOR RETURN AIR (TYPICAL). 3. THRESHOLDS AT EXTERIOR DOORS, ARE NO HIGHER THAN 3/4 INCH. THRE5HOLD5 AND CHANGES IN LEVEL AT THESE LO( ATION5 ARE BEVELED WITH A SLOPE NO GREATER THAN 1:2, 4. REFER TO SHEET 8.6 FOR ALL HEAD, JAMB AND THRE5HOLD DETAILS. 5. PROVIDE I WIDE ANGLE 180° 'PEEP HOLE' VIEWER @ ALL APT. ENTRY DOORS. oa �a s • A VINYL CARPET 4 KITCHEN SS 1 DESIGNATED HANDICAP ACCESSIBLE BATHROOM, "H.A.B." CONFORMING TO FAIR HOUSING ACT. SECTION 100.205(G) (3(IV)). O SEE b SHEET 5.10 FOR DETAILS 6 PANEL FLUSH FLUSH METAL BI -FOLD EXT. DOOR WINDOW 50HEOULE O MARK DESCRIPTION TYPE SIZE INS HDR. HGT. REMARKS W H HD J SILL A SINGLE HUNG I 4'-0" 5'-0" b,q 86 6'a 5%' 6'-8" 56L. GLAZING/EGRESS WIND. BIt If2 3'-b(2) 5'-0 b,a g b b,q 5 b'-8" 5GL. GLAZING gill 1 r� U M Z a Q 00 0 � x Z 0 V 1 z i W C> W � u ar° 0 o E El w ` M W ❑ v b O 1 w `` 'a N Lu � r , W o ~ E = a F- ck� W ❑ = U z a z NOTES: I. ALL GROUND FLOOR UNITS SHALL MEET ALL CODES, LAN5 & GUIDELINES FOR HANDICAP AGGE551BILITY. LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS WITH OPERABLE PARTS ARE TO BE LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE FLOOR. 2. UNDER GUT ALL BEDROOM DOORS 1/2" ABOVE CARPET FOR RETURN AIR (TYPICAL). 3. THRESHOLDS AT EXTERIOR DOORS, ARE NO HIGHER THAN 3/4 INCH. THRE5HOLD5 AND CHANGES IN LEVEL AT THESE LO( ATION5 ARE BEVELED WITH A SLOPE NO GREATER THAN 1:2, 4. REFER TO SHEET 8.6 FOR ALL HEAD, JAMB AND THRE5HOLD DETAILS. 5. PROVIDE I WIDE ANGLE 180° 'PEEP HOLE' VIEWER @ ALL APT. ENTRY DOORS. oa �a s • A VINYL CARPET 4 KITCHEN SS 1 DESIGNATED HANDICAP ACCESSIBLE BATHROOM, "H.A.B." CONFORMING TO FAIR HOUSING ACT. SECTION 100.205(G) (3(IV)). O SEE b SHEET 5.10 FOR DETAILS 6 PANEL FLUSH FLUSH METAL BI -FOLD EXT. DOOR WINDOW 50HEOULE O MARK DESCRIPTION TYPE SIZE INS HDR. HGT. REMARKS W H HD J SILL A SINGLE HUNG I 4'-0" 5'-0" b,q 86 6'a 5%' 6'-8" 56L. GLAZING/EGRESS WIND. BIt If2 3'-b(2) 5'-0 b,a g b b,q 5 b'-8" 5GL. GLAZING 1 NOTES: I, REFER TO SHEET 8.6 FOR ALL HEAD, JAMB AND THRESHOLD DETAILS. O O MNI5)M I V rINIDM —FURDOWN CEILING R CURTAIN ROD r- TOWEL BAR s CURTAIN ROD -� FIBERGLASS TUB ENGL05URE N/ INTEGRAL SOAP DISH 6 TOWEL BAR 50AP DISH FINISH TO FIN15H TOWEL BAR SHOWER RTAIN ROD ZGLA55 TUB "�L05URE N/ SRAL SOAP TOWEL BAR 3/8 U =I -oil 3/8"=1 INT. VAULT RIDGE \� , \X \ZT. LIVING NOTE: VAULTED GLC. @ TOP FLOORS ONLY C� M, BEDROOM NOTE: — �/ BEDROOM #3 INDICATES A 2'-2" DP. x 6-8" FIRE SPRINKLER R15ER HOOK- UP CLOSET. CLOSET APPEARS ONCE PER BUILDING @ GROUND FLOOR ONLY. (SEE ELEVATION SHEET 6.1 THRU 6.3) 0 UNIT B THREE BEDROOM UNIT NOTA PLAN BEDROOM #2 \ II �� II WIG #2- 3 2 �J to 'WIG #3 W n c d _I S UNIT B THREE BEDROOM UNIT DIMENSION PLAN AREA: 1,205 50. FT. 1/4"=1'-0" GENERAL NOTES: A. DIMENSIONS: DO NOT SCALE DRAWINGS, USE ONLY FIGURED DIMENSIONS. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD OR OUT TO OUT OF MASONRY OR CONCRETE, UNLESS OTHERWISE NOTED. INTERIOR ELEVATION DIMENSIONS ARE FROM FINISHED ©RYWALL. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND GONPITION5 AT THE JOB SITE, B. DOCUMENTS: THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN DIMENSIONS, CODE REQUIREMENTS AND OTHER CONDITIONS INDICATED BY THESE DOCUMENTS PRIOR TO PROCEEDING WITH THE NORK. G. BLOCKING AND ROUGH OPENINGS: THE CONTRACTOR SHALL PROVIDE SOLID BLOCKING FOR CABINETRY, BATH A(CE55ORIE5, HANDRAILS, GRAB BARS, ETC., AND ROUGH AA OPENINGS AS REQUIRED. D. EXTERIOR WALL5 AND INTERIOR BEARING WALL5: PROVIDE 3 X 4 #2 5.P.F. (MIN) STUDS @ Ib" O.G., UNLE55 OTHERNI5E NOTED. INSTALL DOUBLE TOP PLATES, TYPICAL, AND SINGLE PRE55URE TREATED BOTTOM PLATE ON FIRST FLOOR. SECOND $ THIRD FLOOR TO HAVE 51NGLE BOTTOM PLATE. E. INTERIOR NON-BEARING WALLS: PROVIDE 2 X 4 STUDS @ 24" O.G, UNLE55 OTHERNI5E NOTED. INSTALL SINGLE TOP PLATE, TYPICAL, AND SINGLE PRESSURE TREATED BOTTOM PLATE ON FIRST FLOOR. SECOND FLOOR TO HAVE SINGLE BOTTOM PLATE. F. GYPSUM WALLBOARD: ALL NON -RATED NALL CON5TRUCTION TO HAVE 1/2" REGULAR GYPSUM WALLBOARD AND ALL FIRE -RATED NALL CONSTRUCTION HAVE 51b" TYPE "X" GYPSUM WALLBOARD, UNLE55 OTHERWISE NOTED. G. BATHROOM VANITY CABINETS: PROVIDE 21" DEEP VANITY CABINETS WITH 22" TOPS, UNLE55 OTHER 15E NOTED. H. CABINET END PANELS: PROVIDE FIN15HED CABINET END PANEL AT ALL EXPOSED CABINET ENDS. 1. SHELVING: PROVIDE VINYL COATED WIRE SHELVING UNLE55 OTHERWISE NOTED. J. EGRESS WINDOW: EACH SLEEPING ROOM MUST CONTAIN AT LEAST ONE EGRE55 WINDOW THAT MUST BE OPERABLE FROM THE IN510E WITHOUT THE USE OF TOOLS. THE WINDOW MUST BE ACCE5515LE TO FIRE DEPARTMENT RESCUE APPARATUS OR BE WITHIN 20 FT. OF GRADE. MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES AND MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES. MINIMUM NET CLEAR OPENING AREA SHALL BE 5.150. FT. MAXIMUM 51LL HEIGHT SHALL BE 44 INCHES, ABOVE FINISHED FLOOR. LEGEND DE516NATE5 INTERIOR BEARING WALL (I HR RATED) CEILING FUR DONN FOR A/C EXCEPT 3RD FLOOR q INS IWA N a M � 1 r� U M Z a Q 00 0 � x Z 0 V 1 z i W C> W � u ar° 0 o E El w ` M W ❑ v b O 1 NOTE: — �/ BEDROOM #3 INDICATES A 2'-2" DP. x 6-8" FIRE SPRINKLER R15ER HOOK- UP CLOSET. CLOSET APPEARS ONCE PER BUILDING @ GROUND FLOOR ONLY. (SEE ELEVATION SHEET 6.1 THRU 6.3) 0 UNIT B THREE BEDROOM UNIT NOTA PLAN BEDROOM #2 \ II �� II WIG #2- 3 2 �J to 'WIG #3 W n c d _I S UNIT B THREE BEDROOM UNIT DIMENSION PLAN AREA: 1,205 50. FT. 1/4"=1'-0" GENERAL NOTES: A. DIMENSIONS: DO NOT SCALE DRAWINGS, USE ONLY FIGURED DIMENSIONS. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD OR OUT TO OUT OF MASONRY OR CONCRETE, UNLESS OTHERWISE NOTED. INTERIOR ELEVATION DIMENSIONS ARE FROM FINISHED ©RYWALL. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND GONPITION5 AT THE JOB SITE, B. DOCUMENTS: THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN DIMENSIONS, CODE REQUIREMENTS AND OTHER CONDITIONS INDICATED BY THESE DOCUMENTS PRIOR TO PROCEEDING WITH THE NORK. G. BLOCKING AND ROUGH OPENINGS: THE CONTRACTOR SHALL PROVIDE SOLID BLOCKING FOR CABINETRY, BATH A(CE55ORIE5, HANDRAILS, GRAB BARS, ETC., AND ROUGH AA OPENINGS AS REQUIRED. D. EXTERIOR WALL5 AND INTERIOR BEARING WALL5: PROVIDE 3 X 4 #2 5.P.F. (MIN) STUDS @ Ib" O.G., UNLE55 OTHERNI5E NOTED. INSTALL DOUBLE TOP PLATES, TYPICAL, AND SINGLE PRE55URE TREATED BOTTOM PLATE ON FIRST FLOOR. SECOND $ THIRD FLOOR TO HAVE 51NGLE BOTTOM PLATE. E. INTERIOR NON-BEARING WALLS: PROVIDE 2 X 4 STUDS @ 24" O.G, UNLE55 OTHERNI5E NOTED. INSTALL SINGLE TOP PLATE, TYPICAL, AND SINGLE PRESSURE TREATED BOTTOM PLATE ON FIRST FLOOR. SECOND FLOOR TO HAVE SINGLE BOTTOM PLATE. F. GYPSUM WALLBOARD: ALL NON -RATED NALL CON5TRUCTION TO HAVE 1/2" REGULAR GYPSUM WALLBOARD AND ALL FIRE -RATED NALL CONSTRUCTION HAVE 51b" TYPE "X" GYPSUM WALLBOARD, UNLE55 OTHERWISE NOTED. G. BATHROOM VANITY CABINETS: PROVIDE 21" DEEP VANITY CABINETS WITH 22" TOPS, UNLE55 OTHER 15E NOTED. H. CABINET END PANELS: PROVIDE FIN15HED CABINET END PANEL AT ALL EXPOSED CABINET ENDS. 1. SHELVING: PROVIDE VINYL COATED WIRE SHELVING UNLE55 OTHERWISE NOTED. J. EGRESS WINDOW: EACH SLEEPING ROOM MUST CONTAIN AT LEAST ONE EGRE55 WINDOW THAT MUST BE OPERABLE FROM THE IN510E WITHOUT THE USE OF TOOLS. THE WINDOW MUST BE ACCE5515LE TO FIRE DEPARTMENT RESCUE APPARATUS OR BE WITHIN 20 FT. OF GRADE. MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES AND MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES. MINIMUM NET CLEAR OPENING AREA SHALL BE 5.150. FT. MAXIMUM 51LL HEIGHT SHALL BE 44 INCHES, ABOVE FINISHED FLOOR. LEGEND DE516NATE5 INTERIOR BEARING WALL (I HR RATED) CEILING FUR DONN FOR A/C EXCEPT 3RD FLOOR q N M � 1 U M Z a Q 00 0 � x Z 0 V 1 z i W C> W � u 0 o E El w ` M W ❑ v b O z 06 w `` 'a N Lu � r , W o ~ E = a F- ck� W ❑ = U z a z � < Q Q J vi a h z O CL x U to Li D w Q > w x L_ V) JOB NO. SSS DRAWN BY P135 CHECKED BY GB APPROVED BY JET DATE 5/15/00 SHEET NO. 5.7