HomeMy WebLinkAbout2343 Blue Grouse Ln 18-4685 PoolSvv*i n!g 2343 Blue Grouse Lane Sanford, Flor*i(J,a 32773 Seminole County Location Map Scale: Not to scale DRAWING INDEX SHEET 1 - COVER SHEET SHEET 2 - NOTES & SPECIFICATIONS SHEET 3 - POOL SITE PLAN SHEET 4 - POOL PLUMBING & LAYOUT PLAN SHEET 5 - POOL DETAILS SHEET b - POOL EQUIPMENT DETAILS SHEET 7 - POOL BONDING PLAN SANFORD BUILDING DIVI lQ J A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK .AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REOUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE PERMIT # /y�.� 400 rAp / 20IJ r SANFORD FIRE DEPARTMENT THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. AN ISSUED PERMIT SHALL BE DEEMED PERMISSION TO PROCEED WITH WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THESE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE FIRE PREVENTION DIVISION FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS ON THE PLANS, CONSTRUCTION OR OTHER VIOLATIONS OF THE CODE, 01=RMIT * -_ __ uj , Sheet 1 of 7 01 C L C 00 6 u I # I Revision Description I Date Date: November 29, 2018 Drawn by: zio o 0 N 4-5 . x O �I tc 0 C L C 00 6 u I # I Revision Description I Date Date: November 29, 2018 Drawn by: zio FENCE: Florida Building Code requires that all public pools shall be surrounded by a minimum 48" high fence. The fence shall be continuous around the perimeter of the pool area that is not otherwise blocked or obstructed by adjacent buildings or structures and shall adjoin with itself or abut to the adjacent members. Access through the barrier other than from doored exits of adjacent building(s) shall be through self-closing, self -latching, lockable gates of 48" minimum height with the latch located a minimum of 54" from the bottom of the gate or at least 3" below the top of the gate on pool side. Gates shall open outward away from the pool area. GENERAL NOTES: 1. Structure suitable when empty for ground water not higher than 6" above main drain. 2. Permanent Tile depth markers, minimum 4" high with contrasting color, slip resistant flush on deck or top of beam not more than 2 feet from water edge and inside back of gutter (glaze minimum 4" high. 3. Permanent Red International NO DIVE Tiles, non -slip flush minimum 4" high, on top of the deck not more than 2 feet from water edge every 25 feet of perimeter maximum see detail. 4. All equipment shall have NSF, UL, or appropriate approval. 5. All electrical, grounding, wiring & bonding to comply with Florida building code FBC 2017, 6th Edition, Chapter 27, NEC 2014, Section 680 and 680.26(C). No overhead power within 10 feet. Electrician must certify compliance to engineer. NEC 680.26(C) requires that all parts specified in 680.26(B) shall be connected to an equipotential bonding grid with solid copper conductor, insulated, covered. or bare, not smaller than 8 AWG or rigid metal conduit of brass or other identified corrosion -resistant metal conduit. Connection shall be made by exothermic welding or by listed pressure connectors suitable for the purpose and are of stainless steel, brass, copper, or copper alloy. 6. Pool make-up water is from an approved source with air gap. 7. No direct connections between water and sanitary systems, minimum 3" gap. 8. Vacuum breakers on all hose bibs in pool area. 9. Minimum 7' vertical clearance above deck and pool water, 10. No food or drink services to be within 12 feet of inner edge pool deck. 11. Walkways between pool and sanitary facilities shall be impervious, slip resistant for the first 15 feet from pool water edge. 12. If night swimming is allowed, overhead lighting shall provide at least 3 foot candles of illuminations at the water and wet deck level. 13. Overhead illumination of 30 foot candles at floor level in equipment room. 14. Owner to provide storage of chemicals under roof, protected from access by unauthorized persons. 15. Owner to provide traffic barriers at deck if needed. 16. Main drain(s) to meet ANSI/APSP 16 NSF50, 64E-9 and comply with Virginia Graeme Baker Act. 17. Feeders to be interlocked with recirculation pump. 18. Pipe: PVC schedule 40 NSFpw 19. Gauges: 2" minimum; 0-60 psi. 20. Test Kit: Taylor 2006 or Equal 21. All electric and ground to meet NEC or local code. 22. The equipment area or collector tank or chemical containers shall not be accessible to unauthorized individuals. 23. Install new equipment and plumbing per manufacturers instructions. 24. Plastic pipe subject to a period of prolonged sunlight exposure must be coated to protect it from ultraviolet light degradation 25. ALL EQUIPMENT MUST BE LABELED AND EASILY READ, THIS INCLUDES THE FLOWMETER. 26. All equipment (pumps, motors, pressure gauges, valves, auto and manual fills, piping, filters, flow indicators and flow meters ) must be operating properly before calling this office and/or the Health Department for inspection. 27. Lighting certification is not part of this submittal. Contact a Lighting or Electrical engineer for certification. 28. Direct access to equipment is required. 29. The equipment enclosure, area or room floor shall be of concrete or other nonabsorbent material having a smooth slip -resistant finish and shall have positive drainage, including a sump pump if necessary. 30. Equipment rooms shall either forced draft or cross ventilation. 31. Pool and Bathhouse electrical outlets to be GFCI with trip points 6mA or less with cover. 32. Pool chemicals to be stored away from other materials in a cool, dry, ventilated area with restricted access. 33. Only NSF -60 approved chemicals shall be provided 34. Pool to have Shepherd's Hook, Straight Pole, Ring Buoy for safety equipment. 35. The deck must not have pits and crevices more than 3s" deep. 36. A flow meter shall be provided with properly located and proper clearances upstream and down stream. 37. A gate to the equipment area must be provide within 10' of the equipment area. 38. The equipment room area must provide clearances for all equipment as prescribed by the manufacturer to allow normal maintenance and removal. 39. All equipment meets NSF/ANSI Standards 50-2007. 40, Recirculation pump must have a hair and lint strainer. 41. All exposed PVC piping will be painted for UV protection. 42. The plans meet FBC 2017, 6th Edition, Section 454.1. 43. The plans meet 2014 National Electric Code 44. All depth markers are to indicate actual depths within 3". 45. Horizontal tile used in less than 5' (1524 mm) of water must be slip resistant. POOL INFORMATION Area: 1,144 Square Feet Perimeter: 135 Linear Feet Capacity: 38,000 Gallons Unit Count: 280 Non Transient Units Turnover: 3.0 Hours Design Flow Rate: 210 GPM Deck Area: 2,525 Square Feet Length: 37'-0" Width: 29'-2" Depth Max: 5'-0" Depth Min: 3'-6" Pool Filter: Vak-Pak AP30, Vacuum D.E., (30) Elements, 3.75 Sq. Ft. Ea. 112.5 Sq. Ft. Total, 225 GPM Capacity Pool Recirculation Pump: Speck 95 -IX, 5.0 HP, 210 GPM @ 50' TDH Pool Vacuum Pump: Pentair 34-0039 1.5 HP Chemical Feeders: Stenner 45M5 (cL), 50 GPD - 40 Gallon Chemical Tank Stenner 45M2 (pH), 10 GPD - 20 Gallon Chemical Tank Valves: Proportional flow, ball globe, or butterfly for return line, main drain, gutter and heater by-pass or approved equal, otherwise gate.Feeders to be wired with failure proof interlock with the recirculation pump. Pipe: PVC Schedule 40 NSFpw Gutter: Pentair 540063 (2" X 4") Flow Meter: Blue White CF30300P 45-240 GPM Flow Range Anchors: Hayward SP1392 Transformers: Area Lighting LG -300/12 Volt Leaf Skimmer: Lion 1010 Vacuum Head: Rainbow 214 Brush: A&B 3004 Vacuum Hose: Plastiflex Shell: Concrete, 3,500 P.S.I., 28 Day, Rigid Construction Steel: ASTM GR40, A615 Poles: (3) Jed, 16' Straight Heater: N/A ADA Lift: None Level (Static) Line Grate: SP1019 Main Drain: 12"x12" VGB Compliant Inlets: Hayward SP1425 Escutcheons: Frost 41661 Lights: Pentair 5G Intellibrite, White LED NEC 2014, Section 680.26 Florida Building Code 2017 Chapter 27 Life Ring: (2) 24" W/ 30' Throw Line, Jim Buoy Hook: (2) Rainbow 153 Test Kit: Taylor K-2006 Ladder: Smith LFB-36B Tread: 6" Maximum from wall, 3" Minimum from wall. Crossed braced stainless steel, slip -resistant treads, 28" minimum above deck. Must have caps or bumpers that rest firmly against pool wall. Finish: Floors and walls shall be white or pastel in color and shall have the characteristics of reflecting rather than absorbing light. The finish coating shall have a dry lightness level (CIE L Value) of 80.0 or greater and a wet luminous reflectance value of (CIE Y) value of 50.0 or greater, as determined by the test results provided by the manufacturer, utilizing testing methodology from American Standard ASTM D4086, ASTM E1477, ASTM E1347. POST POOL RULE SIGN NO DIVIN NO GLASS OR ANIMALS IN THE FENCED POOL AREA NO FOOD OR BEVERAGES IN POOL OR ON POOL WET DECK SHOWER BEFORE ENTERING POOL DO NOT SWALLOW THE POOL WATER MAXIMUM POOL BATHING LOAD: 38 PERSONS POOL HOURS: DAWN a.m. TO DUSK p.m. (until lighting certified) SEE NOTE 3 "NOTES: 1) NO NIGHT SWIMMING ALLOWED PRIOR TO PROVIDING THE DOH WITH AN ENGINEER'S APPROVED DECK ILLUMINATION DESIGN AND PHOTOMETRIC CALCULATIONS STUDY AND RECEIVING APPROVAL FROM THE DOH FOR NIGHT SWIMMING. 2) OWNERSHIP MAY ADD ADDITIONAL RULES TO SIGN. 3) POOL RULES LETTERS TO BE 1" HIGH MIN. EXCEPT "NO DIVING" SHALL BE 4" HIGH MIN. RESTROOM LOCATOR SIGN REST ROOMS PROVIDED BY OWNERSHIP RESTROOMS - 4" BLOCK Outside access to facilities shall be provided for bathers at outdoor pools and if they are not - LETTERS visible from any portion of the pool deck, signs shall be posted showing directions to the facilities. These directions shall be legible from any portion of the pool deck and the letters shall be a minimum of one inch high. Walkways shall be provided between the pool and the F 1" BLOCK LETTERS sanitary facilities, and shall be constructed of concrete or other nonabsorbant material having a smooth slip resistant finish for the first 15 feet of the walkway measured from the nearest pool water's edge. Floors: smooth, non -slip, impervious, pitched to floor drains, cove wall to floor, no carpet, LETTERING TO BE duckboard or footbaths. Provide permanent towel, tissue, soap dispensers and waste DARK AND baskets. Label doors. Install hose bib w/ vacuum breaker, either in resorts or outside nearby. CONTRASTING TO Water shall be from an approved potable source with air break. Diaper changing tables shall BACKGROUND be provided at facilities that cater to families with small children. E* NOTE: Restrooms are located within 200 FT walking distance of pool waters edge. RESTROOM FACILITIES: • ARE WITHIN 200 FEET WALKING DISTANCE FROM THE WATERS EDGE. • SHALL BE AT LEAST AS INDICATED ON THE FOLLOWING TABLE: TOTAL AREA IN SQ. FT. MEN'S URINAL RESTROOM W/C LAVATORY WOMEN'S RESTROOM W/C LAVATORY 0-2,500 1 1 1 1 1 2,501- 5,000 2 1 1 5 1 5,001- 7,500 2 2 2 6 2 7,501-10,000 3 3 3 9 3 OCCUPANT LOAD CALCULATIONS IN ACCORDANCE WITH NFPA 101, 2015 EDITION (FROM TABLE 7.3.1.2 ) SWIMMING POOL WATER SURFACE: SWIMMING POOL DECK AREA: SWIMMING POOL OCCUPANT LOAD TOTAL OCCUPANT LOAD: MINIMUM REQUIRED EGRESSES PER SECTION 7.4.1: PANIC HARDWARE REQUIRED WHEN OCCUPANCY LOAD IS GREATER THAN 100 1,144 + 50 = 22.9 + 2,525 - 30 = 84.2 107.1 107 1-500 2 2 501-1000 3 > 1001 4 THE POOL, DECK AND EQUIPMENT SHOWN ARE DESIGNED TO MEET THE REQUIREMENTS OF THE FOLLOWING APPLICABLE CODES: DEPARTMENT OF HEALTH (DOH) 64E-9 FLORIDA ADMINISTRATIVE CODE FLORIDA STATUTES, CHAPTER 514 FLORIDA BUILDING CODE 2017, SIXTH EDITION FLORIDA PLUMBING CODE, 2017 NATIONAL ELECTRIC CODE (NEC) 2014 NATION FIRE PROTECTION ASSOCIATION 2014 (NFPA) 70 (Update) NATION FIRE PROTECTION ASSOCIATION 2015 (NFPA)101 Sheet 2 of 7 = 1171:14 V 4-1 U n N co cf) 4J J-) �,o di ;-4 � � Zw� cC'S • � p N � r --q L\ .4.5 M C1) . CD cn T. rn LO 00 Lq a J J W i 0 0 Q U Date W Date: November 29, 2018 Drawn by: zoo O O � O bA � � cC'S • � C1) O Z T. rn LO 00 Lq a J J W i 0 0 Q U Date W Date: November 29, 2018 Drawn by: zoo SITE PLAN NOTES: 1. RINSE SHOWER SHALL BE PROVIDED ON THE POOL DECK WITHIN THE PERIMETER OF THE FENCE. 2. HOSE BIBB WITH VACUUM BREAKER REQUIRED ON DECK. 3. WASTE TO STORM COLLECTION SYSTEM WITH AIR GAP, MEET LOCAL CODES, PAINT EXPOSED PVC. EACH WASTE LINE SHALL HAVE A UNIQUE AIR GAP. WASTE LINES FROM DIFFERENT SOURCES SHALL NOT BE TIED TOGETHER, BUT MAY DISCHARGE INTO A COMMON SUMP OR RECEPTACLE AFTER AIR GAP. (CONTRACTOR TO PROVIDE) 4. CONFIRM LOCATIONS AND ELEVATIONS WITH THE OWNER AND LANDSCAPE CONTRACTOR. 5. NO FOOD OR DRINK FACILITIES WITHIN 12 FEET OF POOL 6. PROVIDE A HOSE BIBB WITHIN 25 FEET OF THE RESTROOMS 7. PROVIDE DIRECTIONAL SIGNS TO RESTROOMS / 8. NO RECLAIMED WATER SHALL BE USED AS AN IRRIGATION/ SOURCE FOR THE PLANTER AREAS ALONG THE POOL DECK 9. PAINT ALL EXPOSED PVC. 10. CONTRACTOR TO PROVIDE A MINIMUM 48" OF CLEARANCE AROUND THE POOL PERIMETER. THIS CLEARANCE DISTANCE NEEDS TO BE PROVIDED AND MEASURED FROM THE OUTSIDE FACE OF ANY STEP RAILS AND LADDER ANCHORS. 11. POOL WET DECKS SHALL BE UNIFORMLY SLOPED AT A MINIMUM OF 2% AND A MAXIMUM OF 4% AWAY FROM THE POOL OR TO DECK DRAINS TO PREVENT STANDING WATER. TEXTURED DECK FINISHES THAT PROVIDE PITTING AND CREVICES OF MORE THAN as" DEEP THAT ACCUMULATE SOIL ARE PROHIBITED. IF SETTLING OR WEATHERING OCCURS THAT WOULD CAUSE STANDING WATER, THE ORIGINAL SLOPES SHALL BE RESTORED OR CORRECTIVE DRAINS INSTALLED. Site Plan Scale: 3/16" = V-0" POOL EQUIPMENT PACK MINIMUM 48" uIn u rfrk err POOL RINSE SHOWER WITH HOSE BIBB & VACUUM BREAKER LEGEND E ELECTRICAL SUPPLY S WASTE LINE P POTABLE WATER SUPPLY Sheet 3of7 m W V 14-01 . 7=04 u Q� cn \'0 0000 i N 0 O � Z � N �-4 4-5 O O CIO Date Date: November 29, 2018 Drawn by: zoo O LO O 00 P-4 0 to Cd c� • r A� J 00 W O� N 0 O cn a Date Date: November 29, 2018 Drawn by: zoo cz LO 00 w J J 00 W O� N 0 0 a x U Date Date: November 29, 2018 Drawn by: zoo 3" DIA. MAIN DRAIN 3" DIA. MAXIMUM FLOW VELOCITIES (GPM) PIPE DIAMETER 'GRAVITY 'SUCTION 'PRESSURE 1.5 17 33 55 2.0 29 59 98 3.0 66 132 220 4.0 117 235 392 6.0 264 529 881 8.0 1 470 1 940 1 1,567 ' GRAVITY, MAXIMUM FLOW, IN GPM, AT 3.0 FPS 2 SUCTION, MAXIMUM FLOW, IN GPM, AT 6.0 FPS 3 PRESSURE, MAXIMUM FLOW, IN GPM, AT 10.0 FPS HYDRAULIC DESIGN MEETS FBC 2017, 6TH EDITON LEGEND (2) LIGHTS O (10)ADJUSTABLE FLOOR 00 RETURNS LU (1) 12"x12" MAIN DRAIN LAWSON 0- (15) PENTAIR 540036 GUTTER MLD -FGD -12-12, 12"x12 - "(1) FITTINGS (2"x4") w (I )LEVEL LIMITS OF POOL COPING V (1) VACUUM FITTING (1) LADDER (9) DEPTH MARKER(S) cn (9) "NO DIVING" MARKER(S) NOTES: ® 1. DEPTH MARKERS TO INDICATE a ACTUAL DEPTH WITHIN 3 INCHES. 2. ALL CORNERS TO HAVE A MINIMUM 2" RADIUS. FITTING LOCATIONS AND PIPE ROUTINC ARE SHOWN IN SCHEMATIC FORM TO ILLUSTRATE DESIGN AND INTENT. INFORMATION NOT SPECIFIED OR DETAILED IS ABLE TO BE ADJUSTED BY THE POOL CONTRACTOR TO FACILITATE INSTALLATION OR ADJUST TO FIELD CONDITIONS POOL MAIN DRAIN COVER - 1.5 FPS MAX. FLOW LAWSON MLD -FGD -1212, 12"X12" VGB COMPLIANT MAIN DRAIN COVER WITH 81.31N OPEN AREA; 380 GPM AT 1.5 FPS. POOL PLUMBING PLAN SCALE: 1/4 If = 1'-0" Z :2 POOL LAYOUT SCALE: 1/4 = PLAN 11-011 '-0" Sheet 4 of 7 F -i 259 O w 4-1 N 0 P.* # I Desnrintinn I Date Date: November 29, 2018 Drawn by: zoo L0 00 00 �3 LU 0- 00 00 w N O cn a # I Desnrintinn I Date Date: November 29, 2018 Drawn by: zoo L0 00 LU 0- 00 00 w N O 0 a U x # I Desnrintinn I Date Date: November 29, 2018 Drawn by: zoo I � 28" MIN. S.R. SMITH 1.0" OD 40" MAX. CUSTOM RAIL ANCHOR 46" 9" 9" 9" BULL CAP IP -RESISTANT MARKERS TO WITHIN 3" OF BOTH THESE ACTUAL DEPTHS 2'-6" MIN. STRAIGHT WALL R2'-6' ► MAX. 5'-0" 3'-0" rN. y n e MIN n' 6 y\// ,%\'/✓ j �� f4 � % ANCH 10 MAX. a `/ 11 �J y ... �+ \' `. �/ 'i;!/MAX. / /. /\ +'/ / �•.°'//Y/ /../ /�/. / �';•,,/,,/,�/, •./ a,/ � /....%`�``• % �,../ �,,,/ ��'.�'',•,./, / �'/j:t ,�",.//l/.�.�/.,/i,/ /i:: ,`�, IN 1 4 YD. GRAVEL: � .,�;ti. ,. \4,., , \\ �\ ti;, ,.. NOTE: ALL STEP TILE SHALL BE SLIP -RESISTANT 28" MIN. HEIGHT FOR EACH { RAIL IN Transverse Pool Section, Deep Portion MUNSELL, COLOR VALUE FROM 0-4, (DARK) & RISER BOTTOM STEP CONTINUOUS AROUND ENTIRE STEP. INTERMEDIATE STEPS SHALL BE UNIFORM IN WIDTH Scale: Not to scale. AND HEIGHT. ALL SLIP -RESISTANT TILE SHALL HAVE A COEFFICIENT OF FRICTION OF AT LEAST 0.6 AS MEASURED USING ASTM C 1028. HOOK FOR SHEPHERDS 16' POLE AND SHEPHERDS 4X6 ALUMINUM POST, POWDER COATED RAL 9006, WHITE ALUMINUM, TOP BEVELED, SEE DETAIL SAME PAGE 16' POLE AND SHEPHERDS HOOK HOOK FOR ROPE WITH A SUFFICIENT AMOUNT TO REACH ALL PARTS OF THE POOL LIFE SAVER CONCRETE FOOTER SEE STRUCTURAL DRAWINGS Life Safety Equipment Scale: Not to scale. 4X6 ALUMINUM POST, POWDER COATED RAL 9006, WHITE ALUMINUM, TOP BEVELED, SEE DETAIL SAME PAGE HOOK FOR ROPE WITH A SUFFICIENT AMOUNT TO REACH ALL PARTS OF THE POOL 16' POLE AND SHEPHERDS HOOK –LIFE SAVER LIFE -SAFETY EQUIPMENT MUST BE LOCATED FLUSH WITH POOL DECK CONCRETE FOOTER SEE STRUCTURAL DRAWINGS 6" MIN. MAR VCne 'r^ x"Tulk" 711 OF BOTH THI 2'-6" MIN. STRAIGHT WALL Transverse Pool Section, Shallow Portion Scale: Not to scale. TRUNK PIPE (AS INDICATED ON POOL PLUMBING PLAN) ADJUSTABLE FLUSH FLOOR RETURN HAYWARD SP 1425 L 1.5" DIA' Adjustable Floor Return Detail Scale: Not to scale. 6" MIN. ALLS VERTICAL +/- 5° KCAL +/- 5` 12" COPING (CONFIRM) 6 FLAT SMOOTH :��-7 GLAZED TILE BULL NOSE COPING PAVER DECK: NON SLIP, IMPERVIOUS SMOOTH DECK, PITCH AWAY —)i 1/411 PER FT. MIN. 1/2" PER FT. MAX. •�� 12" / VACUUM FITTING 6" MIN. ---- -./\ WALL i WALLS OF POOL TO BE RIGID MATERIAL. CONCRETE/GUNITE/ `• SHOTCRETE, 6" THICK, 3,500 PSI MIN. WITH #3 REBAR, 12" O.C.E.W. 15" MIN. LAP NOTE: STRUCTURAL SUBJECT T SUITABLE SOIL CONDITIONS j IF SETTLING OR WEATHERING OCCURS THAT WOULD CAUSE STANDING WATER, THE ORIGINAL SLOPES SHALL BE RESTORED OR 12" GUTTER 811 _ MAX. 12" MAX. 18" MIN. BULLNOSE WATERLINE SLIP -RESISTANT TILE 12" MIN. - 12" MAX. (OWNER TO PROVIDE COLOR AND SIZE) UNDERWATER POOL LIGHT EXPOSED AGGREGATE SLIP -RESISTANT (OWNER TO CONFIRM COLOR) 2" 6" MIN. FLOOR r3# REBAR @ 12 CLEAR J O.C.E.W. CORRECTIVE DRAINS INSTALLED. zCLEAR y Gutter, Wall & Floor Detail Scale: Not to scale. 2" I.P.S. HYDROST/ RELIEF TUBE (IF REQUII GRAVEL ROCK (IF REQUII / ' 2"WATERWAY 1720-V :OMPLIANT FLOOR Scale: Not to scale. DRAIN Tb :CTOR T�NK 3LASS DRAIN (SEE DE$AIL ;HEET JG 0 SLIP -RESISTANT 6"X6" MARKER TILE WITH 4" LETTERING BRICK COPING PERMANENT, SLIP -RESISTANT; RED "NO -DIVING" INTERNATIONAL SYMBOL INSTALL MARKER AND NO DIVING TILE ON DECK. TO BE SLIP RESISTANT 12" WIDE BEAM WIT BRICK COPING 4'-0" (48") MIN. CLEARANCE BEHIND LADDER POOL SIDE 4" MIN. 3 TJ 6 1 IN DECK SIDE NOTE: DEPTH MARKERS AND NO DIVING TILE NOT TO BE MORE THAN 24" FROM WATERS EDGE. DEPTH MARKERS TO BE ON DECK AND INSIDE POOL AT WATER LINE. Depth Marker Details Scale: Not to scale. 30" WATERLINE l.� 23 1/2" v 28" 4( EXPOSED AGGREGATE FINISH INSTALL DEPTH MARKER TILE (TO BE SMOOTH OR GLAZED) 6" GLAZED TILE 12" MAX CUSTOM LADDER: SR SMITH CUSTOM, STAINLESS STEEL TREAD: 6" MAX. FROM WALL, 3" MIN. FROM WALL CROSS BRACED, SLIP -RESISTANT TREADS, 28" MIN. 36" MAX. ABOVE DECK. FRAME, 1.90" OD X.065% TYPE 304 STAINLESS STEEL, WITH WHITE RUBBER BUMPERS. STEPS, ACRYLIC PLASTIC AND HAVE SLIP -RESISTANT TOP SURFACE. ESCHUTEON (#EP -100F) STAINLESS STEEL. ANCHOR ASSEMBLY: AS -100B (SEE SPEC SHEET FOR SRS -908) Ladder Detail, Model #10 135 Scale: Not to scale. Sheet 5 of 7 00 O� N # .µ 1\GVIJIVII nimc-rintinn Date Date: November 29, 2018 Drawn by: zoo C 0 m 00 . r..i • 03 O Cq IN rr� O V1 ON N rr .. O. 4^ 0 CIO 00 O� N # .µ 1\GVIJIVII nimc-rintinn Date Date: November 29, 2018 Drawn by: zoo 0 0 . r..i • 03 rr� O V1 00 O� N # .µ 1\GVIJIVII nimc-rintinn Date Date: November 29, 2018 Drawn by: zoo POOL GROUNDING GRID MINIMUM 36" PROJECTION PER NFPA70 680.26(C) EQUIPOTENTIAL BONDING GRID STRUCTURAL STEEL #3 REBAR TIED WITH TIE WIRE AT 12" E.W. AT EACH CROSS-OVER LOCATION. T ALTERNATE MEANS: WHERE STRUCTURAL REINFORCING STEEL IS NOT AVAILABLE OR IS ENCAPSULATED IN A NONCONDUCTIVE COMPOUND, A COPPER CONDUCTOR(S) SHALL BE UTILIZED WHERE THE FOLLOWING REQUIREMENTS ARE MET: (1) AT LEAST ONE MINIMUM 8 AWG BARE SOLID COPPER CONDUCTOR SHALL BE PROVIDED (2) THE CONDUCTORS SHALL FOLLOW THE CONTOUR OF THE PERIMETER SURFACE (3) ONLY LISTED SPLICES SHALL BE PERMITTED (SPLIT -BOLTS) (4) THE REQUIRED CONDUCTOR SHALL BE 450 TO 600 mm (18 TO 24in.) FROM THE INSIDE WALLS OF THE POOL (5) THE REQUIRED CONDUCTOR SHALL BE SECURED WITHIN OR UNDER THE PERIMETER SURFACE 100mm TO 150mm (4in TO On BELOW THE SUBGRADE). CONNECT THIS SINGLE 8 AWG COPPER WIRED WITH SPLIT BOLTS ON THE COPPER "WHIPS" LOCATED AT FOUR EQUAL POINTS OF THE POOL. POOL EQUIPOTENTIAL GRID REQUIREMENT Scale: Not to scale. SECTION I. Installing light fixture during new pool construction. A. Preparatory steps which must be completed by the electrician before light fixture is installed. 1. Verify that the pool meets the current requirements of the National Electric Code and all local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the underwater light is installed. Some of the requirements of the National Electric Code which the pools electrical system must meet are listed below. a. The lighting circuit must have a Ground Fault Circuit Interceptor (GFCI), and an appropriately rated circuit breaker. b. The Junction Box, or for the 12 volt models, the low voltage transformer, must be located at least 8 inches above water level, 4 inches above ground level, and at least 48 inches from the edge of the pool. c. The light fixture and all metal items within 5 feet of the pool must be properly electrically bonded. d. The wet niche must be properly installed so that the top edge of the lens on the underwater light is at least 18 inches below the surface of the water in the pool. e. The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground connector located at the rear of the nice. 2. To be certain that the pools electrical system meets all applicable requirements, the electrician should also consult the local building department. 3. Use only Pentair Pool Products wet niches to insure proper bonding and grounding connections. B. Steps to perform after the electrical system requirements are met. 1. Feed cord through conduit to Junction Box, leaving at least 4 feet of cord at the light fixture to coil around the light. This 4 feet of cord around the light allows the light to be serviced after this pool is filled with water. 2. Cut the cord at the Junction Box, leaving at least 6 inches of cord to make connections. 3. Strip 6 inches of the outer cord jacket to expose the three insulated wires. Be careful not to damage the insulation on the three inner wires. 4. Connect all three wires to the corresponding circuit wires in the Junction Box (black wire to power, white wire to common, and green wire to ground) and secure the Junction Box cover in place. 5. Replace the light assembly into niche and tighten special pilot screw. ........... it To GFCI , Circuit Breaker. & Power Source Rigid Figure 1. #8 AWG Ground Connector bonding is located at rear of niche \ / �� "'— TYPICAL MUNIOR BOND CLAMP TYPICAL J -JUNIOR BOND CLAMP ,,,,,_„ (DIRECT BURIAL) CLAMPED TO REBAR I j (DIRECT BURIAL) CLAMPED TO REBAR WITH WIRE LOOPED THROUGH 1 WITH WIRE LOOPED THROUGH CONNECTOR AND CLAMPED TO , CONNECTOR AND CLAMPED TO STEEL. STEEL. I THIS DRAWING IS A SCHEMATIC I LAYOUT, AND NOT TO SCALE. 1 NOTES: ! TYPICAL J -JUNIOR BOND CLAMP 1 1) #8 SOLID COPPER BONDING WIRE TO BE RUN (DIRECT BURIAL) CLAMPED TO REBAR CONTINUOUS TO POOL FILTRATION EQUIPMENT AND WITH WIRE LOOPED THROUGH � I � CONNECTOR AND CLAMPED TO ELECTRICAL SUPPLY PANEL. STEEL. i 2) BOND TO ALL METALLIC ITEMS LOCATED IN THE POOL AND TO THE REBAR. ` 3) ALL POOL BONDING TO COMPLY WITH NEC. 2014, SECTION 680.26 � 9 I I � I 1 I 3 TYPICAL 1 -JUNIOR BOND CLAMP J(DIRECT BURIAL) CLAMPED TO REBAR I WITH WIRE LOOPED THROUGH TYPICAL J - JUNIOR `, CONNECTOR AND CLAMPED TO C 1 1UN OR BOND CLAMP / \ � (DIRECT BURIAL) CLAMPED TO REBAR / STEEL. WITH WIRE LOOPED THROUGH / \ CONNECTOR AND CLAMPED TO / \ STEEL. /_18" Min. to top of lens Concrete must be cut back around niche to allow for a compacted plaster seal Coil 4 ft. of light cable around fixture NOTE: The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test Kit. The test kit is available from Pentair Pool Products. The electrical system inspection using this kit must be performed by a trained and certified personnel 0 WARNING: Never operate this underwater light for more than 10 seconds unless it is totally submerged in water Without total submersion, the light assembly will get extremely hot, which may result in serious bums or breakage of the lamp or lens. This may result in serious injury to pool users, installers, or bystanders, or in damage to property. POOL BONDING PLAN SCALE: Not to scale. TECHNICAL NOTES -680.26 Equipotential Bonding* (Summarized) (A) Performance. Equipotential bonding is intended to reduce voltage gradients in the area around permanently installed pools, outdoor spas, or outdoor hot tubs by the use of a common bonding grid in accordance with 680.26(B) and (C). (B) Bonded Parts. The parts of a permanently installed pool, outdoor spa, or outdoor hot tub listed in (B)(1) through (B)(7) shall be bonded together with a solid copper conductor not smaller than 8 AWG with listed pressure connectors, terminal bars, exothermic welding, or other listed means [250.8(A)]. Equipotential bonding is not required to extend to or be attached to any panelboard, service equipment, or grounding electrode. (1) Conductive Pool, Outdoor Spa, and Outdoor Hot Tub Shells. (a) Structural Reinforcing Steel. Unencapsulated structural reinforcing steel secured together by steel tie wires is considered bonded. (2) Perimeter Surfaces. An equipotential bonding grid shall extend 3 ft horizontally beyond the inside walls of a pool, outdoor spa, or outdoor hot tub, including unpaved, paved, and poured concrete surfaces. The bonding grid shall comply with (a) or (b) and be attached to the conductive pool reinforcing steel at a minimum of four points uniformly spaced around the perimeter of the walls of a pool, outdoor spa, or outdoor hot tub. (a) Structural Reinforcing Steel. Structural reinforcing steel [680.26(B)(1)(a)] . Author's Comment: The 2008 NEC does not provide any guidance on the installation requirements for structural reinforcing steel when used as a perimeter equipotential bonding grid. (b) Alternate Means. Equipotential bonding conductor meeting the following: (1) 8 AWG bare solid copper bonding conductor. (2) The bonding conductor shall follow the contour of the perimeter surface. (3) Listed splicing devices. (4) Bonding conductor shall be 18 to 24 in. from the inside walls of the pool. (5) Bonding conductor shall be secured within or under the perimeter surface 4 to 6 in. below the subgrade. (3) Metallic Components. Metallic parts of the pool, outdoor spa, or outdoor hot tub structure shall be bonded to the equipotential grid. (4) Underwater Metal Forming Shells. Metal forming shells and mounting brackets for luminaires and speakers shall be bonded to the equipotential grid. (5) Metal Fittings. Metal fittings sized 4 in. and larger that penetrate into the pool, outdoor spa, or outdoor hot tub structure, such as ladders and handrails shall be bonded to the equipotential grid. Note: All pool bonding to comply with Chapter 27 of the FBC, 2017 6th Edition, and NEC 20141 Section 680.26 Sheet 7 of 7 co o ON N N 9 0 U as C� L ,U U I 1 XV Vh71V11 nPccrintinn Date Date: November 29, 2018 Drawn by: zoo 00 LO J-)00 a m a � J c V • N 00 � �1 N � O CIS � 45 Q U O O CIO 1 XV Vh71V11 nPccrintinn Date Date: November 29, 2018 Drawn by: zoo rn LO O � a u.i a *� J O 00 � � O CIS � 1 XV Vh71V11 nPccrintinn Date Date: November 29, 2018 Drawn by: zoo rn LO 00 u.i a J 00 0 N Q U 1 XV Vh71V11 nPccrintinn Date Date: November 29, 2018 Drawn by: zoo