PERMIT NO. BC19-000157 ISSUE DATE: 03/27/2019
CONTRACTOR: GCJ CONSTRUCTION PERMIT TYPE: Roof
JOB ADDRESS: 401 CENTRAL PARK DR
WORK DESCRIPTION: Install 28,400 sq. ft. of TPO roofing system
Post this permit in a conspicuous location outside - Approved plans must be posted with permit for inspection
Leave all work uncovered until inspected and approved -
Permit expires 6 months from date of issue or last approved
inspection
PROTECT FROM WEATHER
REQUIRED BUILDING INSPECTIONS
ROOF DRY -IN FINAL ROOF
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS
APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, AND THERE MAY
BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT
DISTRICTS, STATE AGENCIES OR FEDERAL AGENCIES FBC105.3.3
5`,.Fokn4.
s oCITY OF
FLORIDA
Building Division
Commercial Permit Card
PERMIT NO. BC19-000157 ISSUE DATE: 03/27/2019
CONTRACTOR: GCJ CONSTRUCTION PERMIT TYPE: Roof
JOB ADDRESS:401 CENTRAL PARK DR
WORK DESCRIPTION: Install 28,400 sq. ft. of TPO roofing system
Post this permit in a conspicuous location outside - Approved plans must be posted with permit for inspection
Leave all work uncovered until inspected and approved
Permit expires 6 months from date of issue or last approved
inspection
PROTECT FROM WEATHER
REQUIRED BUILDING INSPECTIONS
ROOF DRY -IN FINAL ROOF
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS
APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, AND THERE MAY
BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT
DISTRICTS, STATE AGENCIES OR FEDERAL AGENCIES FBC105.3.3
E'CS1 a o a
i ROOT i. ZWEMU4 C.xI WVr_ l`I7 W S'ER-KrCl iC w. z I
Roof Calculation Information Sheet
Low Slope
Roof System Slope < 2:12 or 10 deg.
GENERAL INFORMATION: Required
Date: 04/18/2019 Job Name: 500 Central Park Drive
Client: Alpha Roofing & Sheet Metal LLC Address: 500 Central Park Drive Sanford FL 32771
Contact: Ed Johnson
Address: 1477 W Gore Street Orlando FL 32805
Phone: (407) 930-5500 Contact: GCJ Construction
E-Mail: Edjohnson@aalpha-roofcom Contact Phone: (321) 689-5208
Cell: (407) 466-8552 Occupancy Use:
PROJECT INFORMATION: Need By:
Job Type: Eave Height of Roof Deck: FT New Roof Re -Roof 0 Recover
Parapet Continuous Around Perimeter? NoIj Yes (If Yes) Minimum Height above Deck
If Multiple Heights, Attach Sketch of Roof Plan with Deck Heights: Approximate Area: SQ.
Nominal Building Width: 1 FT (If complex, Attach Simple Sketch) Roof Overhang Width:
Deck Material: Steel 0 LWC F__ Concrete 0 CWF / Tectum 0 Wood F7Gypsum 0 Proposed
Roof S stem: BUR a
Mod
Bit Single Ply Other: Insulation: '
i`-Q 0"% TS(j Membrane: Attachment
Method to Deck: Adhere Fasten Base Sheet Fasten Insulation Board W S Proposed
Manufacturer: Preferred Fastener Miami -
Dade NOA #: FL.
Product Appr #: Roof
Slope (if not flat): Roof
Profile: (Circle one) Hip
Roof Product
Acceptance) System Subtype & Page #: Product
Acceptance) System No. & Page #: Check
type if not shown below: Mansard (
Include slope) FLAT
GABLE [;ONO STE STEP TYPEI
TYPEII MULTI
SPAN GABLE JAWTOOTI! Engineering
Calculations Requested: Counter -
Flashing/ T-Bar Gutter
Coping
Caps Metal
Deck: New Deck Design/ Metal Deck Repair Deadload
Calculation Contact
Signature/Date: Engineering
Calculations Requested: 0
Roof Attachment Calculation Wood
Blocking Calculations Eave
Flashings (Drip Edge, etc.) FRoof
Drainage with Parapet Condition Anchor
Rooftop Equipment 1522
NW 113th Terrace • Pembroke Pines, Florida 33026 E-
mail: donna,re-csi.net
yNeo
r4 . era Ski4FORD
CITY
sr.ic$t"F101111A
PERMIT NO. BC19-000158
CONTRACTOR: GCJ CONSTRUCTION
JOB ADDRESS: 500 CENTRAL PARK DR
Building Division
Commercial Permit Card
ISSUE DATE: 03/27/2019
PERMIT TYPE: Roof
WORK DESCRIPTION: INSTALL 30,000 SQ. FT. OF TPO ROOFING SYSTEM
Post this permit in a conspicuous location outside
Leave all work uncovered until inspected and approved
ROOF DRY -IN
Approved plans must be posted with permit for inspection
Permit expires 6 months from date of issue or last approved
inspection
PROTECT FROM WEATHER
REQUIRED BUILDING INSPECTIONS
FINAL ROOF
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR.IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS
APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, AND THERE MAY
BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT
DISTRICTS, STATE AGENCIES OR FEDERAL AGENCIES FBC105.3.3
Grant Malo , Clerk Of The Circuit Court & Comptroller Seminole County, FLInst #201930343 Book:9320 Page:1210, (1 PAGES) RCD: 3/25/2019 9:19:51 AMRECFEE $10.00
THIS INSTRUMENT PREPARED BY:
Name: Johan H4nandez
Address
NOTICE OF CO11111 CEMENT'
CEPMFIED CONLE
G2,dT Art ttl`t
r^
J 1`rtK
Py
Pate.
Permit Number.
Parcel ID Number. 28-19-30-509-0000-0090
The undersigned heret•,y gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, thefollowingInformationisprovidedinthisNoticeofCommencement.
ti. D S R(t TI.01LOp pltopER7Y AIl818 V!t o3ih"Tperty and street address if available)
2.
3. OWNER INFORMATION OR 1-E8$12E INFORMATION IF THE LESSEE CONTRACTEI) FOR THE JMpROVEMENT
Name and address:. CENTRAL CANAL_ CO LLC 12039 SW 117TH CT MIAM! FL 33186-5202
Interest in r' OWherpgym- _ ..............
Fee Simple 1111e Holder 0 other than' Owner Rated above) Name:
a. coNTRAcTOR: Nafne! 9CJ C-0%trudf)on Inc Phone Number 321-688 5 08
Address, 4623 13Hdgeton Lane, Orlando FI: 32817
5: • SURETY (tfappltdablra, a copy of the payment borid is alladhed)S Name:
Addressi.. Amount of Bond:
6. LENDERS Name __- _ Phone Number'.-_
Address;
7. Persona within the State of Florida Deglgnated by Owner upon whom notice or other dcodritmritw IfilyEt# gdrved 8speovfded by Saa6ori713.13(1)(a)7., Florida statutes.
Name: _ ---- -- Phone Numberr -
Address:_._---
S. In addfi6n, Owner designates ___.. .. of
to reoeive a copy of the 1.10ndrs Notice as provided in Igaetion 113.f3(t)(t ), Florida Statutes: Phone ntimber:.-_
9. Expirrttion Date of Notice of CoMmeotemant (Tha aitprratidn is 1 year from date ofredording urile#s a different date is apeciflad)
W_ T4 -0 7VE--R ANY PAYMENTS MADE 9Y THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMEND€MENT ARECONSIdRE0IMPPERPAYMENTSUNDERCHAPTER713, PART 1, 8ECTiON 71312; FLORIDA STATUTes AND CAN nEsULT IN" YOUR PAYINGTWICEFORIMPROVEM€NT€ TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECOROEO AND POSTED ON THE JOBSITEBEFORETHEKIRSTINSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORECOMMENCINGWORKORRECORDfNGYOURNOTICEOFCOMMENCEMENT. r
agnewie
of Owner ar LeesSe, or Domes of assee's (Pdnt Name and Provide SVIalory•sTitle/oMce) AWHad.ed OfkciffbiroUor/PameriM eo state
of _ 0 County of ,. D q TheforegoingInstrumentwasacknowledge _before me this O day of -/ t 0 by
W/Z- who Is personally known to me Namedfpenma"zitatcmmt , who
has produced identification 0 type of identification produced. EMR
8, 2
We protect
what matters most"
April 16, 2019
Technical Services
1 Campus Drive
Parsippany, NJ 07054
Alpha Roofing and Sheet Metal
1477 W Gore Street
Orlando, FL 32805
Subject: Contractor/System Certification
Project: 300 Northstar Court
401 Central Canal
500 Central Park Drive
To Whom It May Concern:
Alpha Roofing and Sheet Metal of Orlando, FL is a GAF Master Select roofing contractor for asphaltic, single -ply and
restoration roofing systems and is eligible to obtain a GAF Diamond Pledge TM (NDL) guarantee for up to 20 years.
GAF specification T-RB-R-I-60 is eligible to receive a 20 year GAF Diamond PledgeT"' (NDL) guarantee; provided all
current GAF application requirements are followed and guarantee procedures are met.
T-1113-11-I-60 — Existing Standina Seam Metal Roof (Min. 16ga Purlins)
Flute Fill Insulation: Install flute fill insulation in accordance with GAF application recommendations.
EnergyGuardTM Polviso Insulation: Preliminarily fasten 1" EnergyGuardTM polyiso insulation to the existing
standing seam using Drill-TecTM #12 standard fasteners and 3" steel plates, 6 fasteners per 4' x 8' board.
EverGuard® 60 mil TPO Membrane: Install EverGuard° 60 mil TPO membrane using Drill-TecTM Purlin fasteners
and Drill-TecTM RhinoBond° TPO XHD plates, fastened along the purlins, spaced maximum 60" on center, at a rate
described below. The membrane is then bonded to the plates using the RhinoBond® portable bonding tool in
accordance with GAF application recommendations.
Field: 12" on center along the purlins
Perimeters: 6" on center along the purlins
Corners: 6" on center along the purlins
The above listed system will provide up to 90psf (-45psf) of wind uplift resistance in the field of the roof when installed in
accordance with NEMO ETC, LLC (R-132) evaluation report #010506.09.05 — R33 for FL5293 — R32, page 98 of 101.
GAF has provided the above fastening pattern solely as a courtesy and recommends that the uplift resistance
requirements be verified by a design professional.
If you have any further questions, please contact us at 1-800-766-3411.
Sincerely,
Ja vnie/ Dwva V
Jamie Duvall
Sr. Technical Representative
T-RB-R-1-60 FBC90 300 Northstar Ct 401 Central Canal 500 Central Park Dr — Alpha Roofing 041619 jd
ONEmo I etc,
System Substrate Insulation Layer
Attachment - Roof Cover MDP (psf)
Fasteners (Note il) SpacingNo. Note 1)
Existing standing seam or lap seam metal One or more layers, any Drill -Tee Hex -Head Purlin Fasteners and Drill- EverGuard TPO bonded to Drill -Tee RhinoBond TPO XHD
R-172. roof covers having min. 16 gauge combination, preliminarily Tec RhinoBond TPO XHD Plates are fastened
18inch Plates with RhinoBond Portable Bonding Tool, per 30.0
inch), 50 ksi min. gauge (0.
mc
in.), 3605in.), fastened through to purlins along purlinspurlins manufacturers published instructions.
ksi steel purlins spaced max. 60-inch o.c. in a
Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
R-173. roof covers having min. 16 gauge (0.0598 combination, min. 2--inch XHD Tread Safe Plates are
18-inch o.c. Tread Safe Plates with RhinoBond Portable Bonding 30.0
inch), 50 ksi or min. 12 gauge (0.105 in.), 36 total thickness, preliminarily t roufastenedthrough to purlinsfastened
along purlins Tool, per manufacturer's published instructions. ksi steel purlins spaced max. 60-inch o.c. fastened
Existing min. 15/32-inch plywood atop min. Drill -Tee 914 (min. 1.05-inch embedment) and 12-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
R-174. Nominal 2 x 8 inch lumber supports spaced One or more layers, any Drill-Tec RhinoBond TPOXHD Plates are along wood Plates with RhmoBond Portable Bonding Tool, per 30.0
max. 96-inch o.c.
combination, loose ,
any
fastened through to wood supports supports manufacturer's published instructions.
Existing min. 15/32-inch plywood atop min. One or more layers, any Drill-Tec #14 (min. 1.05-inch embedment) and 12-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
R-175. Nominal 2 x8 inch lumber supports spaced combination, min. 2-inch Drill-Tec RhmoBOnd TPO XHD Tread Safe along wood Tread Safe Plates with Rhino Band Portable Bonding 30.0
max. 96-inch o.c. total thickness, loose laid Plates are fastened through to wood supports supports Tool, per manufacturer's published instructions.
Existing standing seam or lap seam metal One or more layers, any Drill-TecPurlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
R-176. roof covers having min. 16 gauge (0.0598 combination, preliminarily RhinoBond TPO XHD Plates are fastened
12-inch o.c. Plates with RhinoBond Portable Bonding Tool, per 37.5
inch), 50 ksi or min. 12 gauge (0.105 in.), 36 fastened through to purlins along purlins manufacturer's published instructions.
ksi steel purlins spaced max. 60-inch o.c.
Existing standing seam orlap seam metal One or more layers, any Drill-TecPurlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
R-177. roofcovers having min. 16 gauge (0.0598 combination, min. 2-inch RhinoBond TPO XHD Tread Safe Plates are
12-inch o.c. Tread Safe Plates with RhinoBond Portable Bonding 37.5
inch), 50 ksi or min. 12 gauge (0.105 in.), 36 total thickness, preliminarily fastened through [o purlins along purlins Tool, per manufacturers published instructions.
ksi steel purlins spaced max. 60-inch o.c. fastened
Existing standing seam orlap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
R-178. roofcovers having min. 14 gauge (0.0747 combination, preliminarily Rhino Bond TPO XHD Plates are fastened
18-inch o.c. Plates with RhinoBond Portable Bonding Tool, per 37.5
inch), 50 ksi or min. 12 gauge (0.105 in.), 36 fastened through to purlins
along purlins manufacturer's publishedinstructions.
ksi steel purlins spaced max. 60-inch O.C.
Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
R-179. roof covers having min. 14 gauge (0.0747 combination, min. 2-inch XHD Tread Safe Plates are
18-inch o.c. Tread Safe Plates with RhinoBond Portable Bonding 37.5
inch), 50 ksi or min. 12 gauge (0.105 in.), 36 total thickness, preliminarily t roufastenedthrough to purlinsfastened
along purlins sTool, per manufacturer's published instructions.
ksi steel purlins spaced max. 60-inch o.c. fastened
Existing min. 15/32-inch plywood atop min. Drill-Tec #14 (min. 1.05-inch embedment) and 24-inch o.c. EverGuard TPO bonded to Drill-Tec RhmoBond TPO XHD
R-180. Nominal 2 x 8 inch lumber supports spaced One or more layers, any Drill RhinoBond TPO XHD Plates are along wood Plates with RhinoBond Portable Bonding Tool, per 37.5
max. 48-inch o.c.
Combination, loose laid fastened through to wood supports supports manufacturer's published instructions.
Existing min. 15/32-inch plywood atop min. One or more layers, any Drill-Tec #14 (min. 1.05-inch embedment) and 24inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
R-181. Nominal 2 x 8 inch lumber supports spaced combination, min. 2-inch Drill-Tec RhinoBond TPO XHD Tread Safe along wood Tread Safe Plates with RhmoBond Portable Bonding 37.5
max. 48-inch o.c. total thickness, loose laid Plates are fastened through to wood supports supports Tool, per manufacturer's published instructions.
Existing standing seam or lap seam metal One or more lay ny Dr.II:Te, Hnx Head Purlin Fasteners and Drill- EverGuard TPO bonded t D ll Tec RhmoBond TPO XHD
73f fnv4 s Pa n'fiffi. 1F g"aufy9 fflA ^ t;#50iii5Fiefi, F7aliiy-inertly Tec Rhinoeond TPO XHD Plates aret'a"S[3ndd n, h o s, I Fldtes with W C,66nd Portable 9 ndI g Ido'1, fief 45.0
inch), 50 ksi or min. 12 gauge (0.105 in.), 36 fastened through to purlins along purlinsal manufacturers published instructions. Pu
ksi steel Purlins spaced max.60-inch o.c.
NFM& fife, LLB Evaluation Report 01506.09.05-R33 for F02MAJ2
Certificate of Authorization H32455 V 6difidd (2W) W N@N=HVHZ NALWON Revision 33: 12/17/2018 Prepared
by: Robert Niernmen, PE-59166 GAP EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 98 of 101
Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County, FLInst #2019030342 Book:9320 Page:1209; (1 PAGES) RCD: 3/25/2019 9:19:50 AM
REC FEE $10.00
THIS INSTRUMENT PREPARED BY. -
Name: Johan Hernandez
Address. Of lal Ida M. 2l28 IT
r'i4?:i1,.i 000PY GP,Adi p;ic l_OY ,.,
C,pIj-f YCLERK
NOTICE
2. GENERAL DESCRIPTION OF
3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT:
Name and address: CENTRAL CANAL CO LLC _.. 12039 SW 117TH_CT MIAMI, PL331867-5202
Interest In property". Owner
F" Simple TM6 Holder (if other than owner listed above) Name:
Address;_
4. CONTRACTOR: Nadia. CCJ_COnStIUCtIOn In¢ ____ Phone Number. - 321tafig=5206-
Address:.4623 8r10gdt6n.Lene, Ortando Ff. 32817-
fi. SURa TY (i(applieatile, a copy of tfio payment bon8 is attached): Nariie:_ ___ _. _ __._ _ _ _
Address::_ _ _._.._ ____ __- Amount ofBond:-
6. LENDna Name: _--... _._- _ _ Phone Number.._
Addres+s3
1; Pdrboit8 *Itftin the State of Florida De$ignitied by Owner Upon whom notice or cilhor documents dilly be served as Oeovided by Section
713_'IE(1IIaj7., Flotilla Statutes,
Name:. __ _ _ Phone Number.
AddreBsi_._..
8: In addition, Owner desigr3ates _ _. Of ._
to receive a copy of the Ltehd?s Notice as provided in Section 713.13(1)(b), Florida statutes. Phone number.
9. Eitpiratlori Date ofNotice of commencement (The expiration Is 1 year from date of recording unifte a different data isepeeired)
INS -L ._ _ . E i ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE
CO ISIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, S€CTION 713 13; FLORIDA STATUTE6, AND CAN REitILT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND P08TW- ON THEJOBSITEBEFORETHEFIRSTINSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTQRNEY
BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT:
Signshirb df Owner or Lessee, or - rs or Lessw's (Print Nance acid Provide Gkjna oty'sTitefOMee)
Avirofted OfEtedDlreGddP 'ager)
State off County ofl
The foregoing Instrument was acknowledged bbefore me this , day of /'// Y r 20/
by [ s GY 4/ 7`5 C 0/ Who Is personally known to map OR
Name of ,person meting statement
who has produced Identification 0 type of identification produced;
7 "% $EGA B. CENDAN
MY cOMMISSiON 4GGb9466 Notary Sgnaiure
aee F WIRES: September 23.2022
00_ s.ni aRI9ifG CACG t,L;?l?127NS;It"YIC. 71fC.
Roof Calculation Information Sheet
Low Slope
Roof System Slope < 2:12 or 10 deg.
GENERAL INFORMATION: Required
Date: 04/18/2019 Job Name: 401 Central Park Drive
Client: Alpha Roofing & Sheet Metal LLC. Address: 401 Central Park Drive Sanford FL 32771
Contact: Ed Johnson
Address: 1477 W Gore ST Orlando, FL 32805
Phone: (407) 930-5500 Contact: GCJ Construction
E-Mail: Edjohnson@a alpha-roof.com Contact Phone: (321) 689-5208
Cell: (407) 466-8552 Occupancy Use:
PROJECT INFORMATION: Need By:
Job Type: Eave Height of Roof Deck: D V FT New Roof Re -Roof Recover
Parapet Continuous Around Perimeter? No V1 Yes (If Yes) Minimum Height above Deck
If Multiple Heights, Attach Sketch of Roof Plan with Deck Heights: Approximate Area: -a-"5n SQ.
Nominal Building Width: FT (If Complex, Attach simple sketch) Roof Overhang Width:
Deck Material: Steel 71 LWC F—] Concrete F__] CWF / Tectum F—] Wood F-1 Gypsum F7
Proposed Roof System: BUR Mod Bit Single Ply Other:
Insulation:Membrane:
Attachment Method to Deck: Adhere Fasten Base Sheet Fasten Insulation BoardC.CeS
Proposed Manufacturer: Preferred Fastener
Miami -Dade NOA #:
FL. Product Appr #:
Roof Slope (if not flat):
Roof Profile: (Circle One)
Hip Roof
Product Acceptance) System Subtype & Page #:
Product Acceptance) System No. & Page #:
Check type if not shown below:
Mansard (Include slope)
FLAT GABLE Moro STE XSTEP
TYPE I TYPE II
MULTI SPAY GABLE JAWTIIT
Contact
Engineering Calculations Requested:
Counter -Flashing/ T-Bar
Gutter
Coping Caps
Metal Deck: New Deck Design/ Metal Deck Repair
Deadload Calculation
Engineering Calculations Requested:
Roof Attachment Calculation
F]Wood Blocking Calculations
17 Eave Flashings (Drip Edge, etc.)
F7Roof Drainage with Parapet Condition
F7Anchor Rooftop Equipment
1522 NW 113`h Terrace • Pembroke Pines, Florida 33026
E-mail: dongre-csi.net
HONE(K) • • O • RECSC
L 24-
e ROOF ENGINEERING C_AXCUL 170JVSER'VICE INC.
FL.CERT. OFAUTH.# 31333
don@re-csi.net
ROOF WIND PRESSURE & ATTACHMENT DESIGN
CLIENT: ALPHA ROOFING & SHEET METAL, LLC. Page 1 of 2
PROJECT NAME: 401 CENTRAL PARK DRIVE
DATE:04/22/2019
RE-CSI #19-086-401-cpark-tpo
PERMIT#BC19-000157
PROJECT ADDRESS:
401 CENTRAL PARK DRIVE
SANFORD, FL. 32771
PROJECT DATA:
HEIGHT: z := 24 ft.
WIDTH: W := 231 ft.
Continuous Parapet => 3 FT.: NO
ENCLOSURE CLASS.: ENCLOSED
BLDG. RISK. CATEGORY: II
SHAPE: FLAT
REGION: SEMI -OPEN TERRAIN
WIND VELOCITY: V:= 140 MPH
mm
EXPOSURE: C
TOPO. FACTOR: H / Lh < 0.05
USE Kzt:= 1.0
DIRECTIONAL FACTOR: Kd:= 0.85
DESIGN CRITERIA:
FLORIDA BUILDING CODE
EDITION 2017
WIND DESIGN perASCE 7-10
Method 2: Analytical Procedure
DESIGN SCOPE:
Wind Uplift Loads
Mechanically Attached GAF TPO
EDGE ZONE MULTIPLIER:
Trial Calculations: ( 3' min
z- 0.40 = 9.6
PV-0.10 = 23.1
Use Multiplier a := 10 ft
PROJECT DATA based on information provided by Client.
GAF 60-mil TPO:
EXPOSURE C
z min = 15 ft.
PRESSURE COEFFICIENT
2
Kz := 2.01•
z
9.5
900
Kz = 0.937
CALCULATE VELOCITY PRESSURE
qz := 0.00256-Kz-Kzt Kd• V2
qz = 39.97 PSF
Dqz := 0.6-gz
COMPONENTS & CLADDING
EXTERNAL COEFFICIENT GCp
From Figures 30.4-2A
INTERNAL COEFFICIENT: GCpi
From Figure 26.11 -1
CALCULATE UPLIFT ASCE-7-10 DESIGN PRESSURES:
P:= qz-[(—GCp) + (GCpi)]
FIELD PI := Dqz.[(-1.0) + (-0.18)] =—28.299
EDGE P2 := Dqz- [(-1.8) + (-0.18)] =—47.485
CORNER P3 := Dqz-[(-2.8) + (-0.18)] =—71.467
41
xowe a
RE-CST o o e
24"
a• ROOT ENGIJVEER"N CALC11L A-17ONSERTICE, INC.
FL.CERT. OFAUTH.# 31333
don@re-csi.net
ROOF WIND PRESSURE & ATTACHMENT CALCULATIONS
GAF 60-mil TPO:
METHOD OF ATTACHMENT. MECHANICALLY ATTACHED ROOF COVER
ROOF SYSTEM ENGINEERING DATA:
MfglType: GAF MATERIALS CORP.
Florida Product Approval #5293-R32, Pg. 98 Type C-2 System No. R-182
DESIGN PRESSURE: DP:= —45 psf
DECK MATERIAL: EXISTING STANDING SEAM METAL ROOF (16 GA. PURLINS)
INSULATION: FLUTE FILLER & 1.0" ENERGY GUARD POLYISO (PRELIM ATTACH)
FASTENER: DRILL-TEC #12 FASTENERS & 3" STEEL PLATES
MEMBRANE: EVERGUARD 60-mil TPO
PURLIN SPACING: PS := 60 IN
FASTENER SPACING: FS := 12 IN ALONG 16 GAUGE PURLINS (FIELD)
FS2 := 6 IN ALONG 16 GAUGE PURLINS (PERIMETER)
FS3 := 6 IN ALONG 16 GAUGE PURLINS (CORNER)
CONSTRUCTION TYPE: RECOVER
DESIGN FORMULA per RAS NO. 137:
FASTENER SPACING
fv•144
FS :_
P• RS
TRIAL CALCULATIONS:
Page 2 of 2
DATE: 04/22/2019
RE-CSI #19-086-401-Cpark-tpo
PERMIT#BC19-000157
PRELIMINARY ATTACHMENTS:
6 FASTENERS PER 4' x 8' BOARD
ATTACHMENT CALCULATIONS:
FASTENERS SPACED 12" O.C. IN
6" LAPS. ROWS SPACED 60" O.0
FASTENER DESIGN VALUE:
PS-FS
v . DP
144 )
fv = —225 LB
DP = --45 1 >: o PI =—28.299
fv•144 11.372
P2•PS
fv 144 7.556
P3 -PS
ATTACH TO DECK AS FOLLOWS:
FIELD ( Zone 1 ): ATTACH 12" O.C. ALONG 16 GAUGE PURLINS AT 5-FOOT PURLIN SPACING
PERIMETER (Zone 2): ATTACH 6" O.C. ALONG 16 GAUGE PURLINS AT 5-FOOT PURLIN SPACING
CORNER (ZONE 3): ATTACH 6" O.C. ALONG 16 GAUGE PURLINS AT 5-FOOT PURLIN SPACING
DIMENSION OF EDGE ZONES:
WIDTH at PERIMETER a = 10 FT.
CORNER LENGTH: a = 10 FT.
The Roof Code Provisions in Chapter 15 of the
Florida Building Code 2017Apply To This Work.
PS = 60 IN.
BPS = 60 IN.
PS = 60 IN.
Digitally
signed by
ia a.0
Donald J
Flood
lr Date:
2019 04:23`=
15:31:42
04'00'
r- -
We protect
what matters most -
April 16, 2019
Technical Services
1 Campus Drive
Parsippany, NJ 07054
Alpha Roofing and Sheet Metal
1477 W Gore Street
Orlando, FL 32805
Subject: Contractor/System Certification
Project: 300 Northstar Court
401 Central Canal
500 Central Park Drive
To Whom It May Concern:
Alpha Roofing and Sheet Metal of Orlando, FL is a GAF Master Select roofing contractor for asphaltic, single -ply and
restoration roofing systems and is eligible to obtain a GAF Diamond PledgeTI (NDL) guarantee for up to 20 years.
GAF specification T-RB-R-I-60 is eligible to receive a 20 year GAF Diamond PledgeTM (NDL) guarantee; provided all
current GAF application requirements are followed and guarantee procedures are met.
T-RB-R-I-60 — Existing Standing Seam Metal Roof (Min. 16ga Purlins)
Flute Fill Insulation: Install flute fill insulation in accordance with GAF application recommendations.
EnergyGuardTM Polviso Insulation: Preliminarily fasten 1" EnergyGuardTM polyiso insulation to the existing -A
standing seam using Drill-TecTM #12 standard fasteners and 3" steel plates, 6 fasteners per 4' x 8' board.
EverGuard° 60 mil TPO Membrane: Install EverGuard° 60 mil TPO membrane using Drill-TecTM Purlin fasteners
and Drill-TecTM RhinoBond® TPO XHD plates, fastened along the purlins, spaced maximum 60" on center, at a rate„
described below. The membrane is then bonded to the plates using the RhinoBond° portable bonding tool in
accordance with GAF application recommendations.
Field: 12" on center along the purlins
Perimeters: 6" on center along the purlins
Corners: 6" on center along the purlins
The above listed system will provide up to 90psf (-45psf) of wind uplift resistance in the field of the roof when installed in
accordance with NEMO ETC, LLC (R-132) evaluation report #010506.09.05 — R33 for FL5293 — R32, page 98 of 101.
GAF has provided the above fastening pattern solely as a courtesy and recommends that the uplift resistance
requirements be verified by a design professional.
If you have any further questions, please contact us at 1-800-766-3411.
Sincerely,
Ja vni,P,'Du vaW
Jamie Duvall
Sr. Technical Representative
T-RB-R-1-60 FBC90 300 Northstar Ct 401 Central Canal 500 Central Park Dr — Alpha Roofing 041619 jd
n
o
b y.. tip_ -• NO
System Substrate Attachment RoofCover MDP (psf) Insulation LayerIR-172.
roof
No. ( Note 1 ) Fasteners (Note 11) Spacing
Existing standing seam or lap seam metal One or more layers, any Drill-Tec Hex -Head Purlin Fasteners and Drill- EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
covers having min. 16 gauge (0.0598 combination, Tec Rhinogond TPO XHD Plates are fastened 18-inch o.c. Plates with Rhinogond Portable Bonding Tool, per 30.0
inch), 50 ksi ormin. 12 gauge (0.105 in.), 36 preliminarily
fastened through to purlins
alon dinsgpu manufacturers published instructions.
ksi steel purlins spaced max. 60-inch o.c.
Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec Rhinogond TPO XHD
roof covers having min. 16 gauge (0.0598 combination, min. 2-inch Rhinogond TPO XHD Tread Safe Plates are 18-inch o.c. Tread Safe Plates with RhinoBond Portable Bonding 30.0
R-173. inch), 50 ksi or min. 12 gauge (0.105 in.), 36 total thickness, preliminarily fastened through to purlins along purlins Tool, per manufacturer's published instructions.
ksi steel purlins spaced max. 60-inch O.C. fastened
Existing min. 15/32-inch plywood atop min. Drill-Tec #14 (min. 1.05-inch embedment) and 12-inch o.c. EverGuard TPO bonded to Drill-Tec Rhinogond TPO %HD
R-174. Nominal 2 x 8 inch lumber supports spaced One or more layers, any Drill-Tec Rhinogond TPO XHD Plates are along wood Plates with Rhinogond Portable Bonding Tool, per 30.0
max. 96-inch o.c.
combination, loose laid fastened through to wood supports supports manufacturer's published instructions.
Existing min. 15/32-inch plywood atop min. One or more layers, any Drill-Tec #14 (min. 1.05-inch embedment) and 12-inch o.c. EverGuard TPO bonded to Drill-Tec Rhinogond TPO XHD
R-175. Nominal 2 x 8 inch lumber supports spaced combination, min. 2-inch Drill-Tec Rhinogond TPO XHD Tread Safe along wood Tread Safe Plates with Rhinogond Portable Bonding 30.0
max. 96-inch o.c. total thickness, loose laid Plates are fastened through to wood supports supports Tool, per manufacturer's published instructions.
Existing standing seam orlap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec 12-inch o.c.
EverGuard TPO bonded to Drill-Tec Rhinogond TPO XHD
roof covers having min. 16 gauge (0.0598 combination, preliminarily Rhinogond TPO XHD Plates are fastened Plates with Rhino0ond Portable Bonding Tool, per 37.5
R-176. inch), 50 ksi or min. 12 gauge (0.105 in.), 36 fastened through to purlins
along purlins manufacturer's published instructions.
ksi steel purlins spaced max. 60-inch o.c.
Existing standing seam or lap seam metal One or more layers, any Drill -Tel Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO XHD
roof covers having min. 16 gauge (0.0598 combination, min. 2-inch Rhinogond TPO XHD Tread Safe Plates are
12-inch o.c. Tread Safe Plates with Rhinogond Portable Bonding r -37.5
R-177. inch), 50 ksi or min. 12 gauge (0.105 in.), 36 total thickness, preliminarily fastened through to purlins along ourgou Tool, per manufacturer's published instructions.
ksi steel purlins spaced max. 60-inch o.c. fastened
Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec Rhinogond TPO XHD
roof covers having min. 14 gauge (0.0747 combination, preliminarily RhinoBond TPO XHD Plates are fastened 18-inch o.c. Plates with Rhinogond Portable Bonding Tool, per 37.5
R-178 inch), 50 ksi or min. 12 gauge (0.105 in.), 36 fastened through to purlins
along purlins manufacturer's published instructions.
ksi steel purlins spaced max. 60-inch o.c.
Existing standing seam orlap seam metal One or more layers, any Drill -Tel Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec Rhinogond TPO XHD
roofcovers having min. 14 gauge (0.0747 combination, min. 2-inch Rhinogond TPO XHD Tread Safe Plates are 18-inch o.c. Tread Safe Plates with Rhinogond Portable Bonding 37.5
R-179. inch), 50 ksi or min. 12 gauge (0.105 in.), 36 total thickness, preliminarily fastened through to purlins along purlins Tool, per manufacturer's published instructions.
ksi steel purlins spaced max. 60-inch o.c. fastened
Existing min. 15/32-inch plywood atop min. Drill -Tel #14 (min. 1.05inch embedment) and 24-inch o.c. EverGuard TPO bonded to Drill-Tec RhmoBood TPO XHD
R-180. Nominal 2 x 8 inch lumber supports spaced
One or more layers, any Rhinogond TPO XHD Plates are along wood Plates with Rhinogond Portable Bonding Tool, per 37.5
max. 48-inch o.c.
combination, loose laid fastened through to wood supportsfastenedgPP supportsPP manufacturers published instructions.
Existing min. 15/32-inch plywood atop min. One or more layers, any Drill-Tec #14 (min. 1.05-inch embedment) and 24-inch o.c. EverGuard TPO bonded to Drill-Tec Rhinogond TPO XHD
R-181. Nominal 2 x 8 inch lumber supports spaced combination, min. 2-inch Drill-Tec Rhinogond TPO XHD Tread Safe along wood Tread Safe Plates with RhinoBond Portable Bonding 37.5
max. 48-inch o.c. total thickness, loose laid Plates are fastened through to wood supports I supports Tool, per manufacturer's published instructions.
Existing standing seam or lap seam metal One or more layers;any Drill:TE, HE Had Purlin Fasteners and Drill- EverGuard TPO bonded to D II Te RhinoBond TPO XHD
I rfit?f V,,v! 9 fR..n 7itn f. 45..0-1 (0.Ci„^:p L'di9i(i`flfitidfi, pfell:r indriiy Tec Rhinogond fPO XHD Plates are fSstaa I :2-.n h o:c. PISF! with RYlfidfidnd Portable F1 d fig Id01, iilf 45.0
inch), 50 ksi or min. 12 gauge (0.105 in.), 36 fastened through to purlins along purlins manufacturers published instructions+
ksi steel purlins spaced max. 60-inch o.c.
N9M6 FfGr M Evaluation Report 0150b.09.05-R33 for F69293=R32
Certificate of Authorization #32455 Bie B0lfian (260) PAC NON10141 NALUAfiON Revision 33: 12/17/2018
Prepared by: Robert Nieminen, PE-59166 GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 98 of 101
Z. Ita•
I T'00-F r CjLaMf_A7VWsue.Yrcz mc.
FL.CERT. OF AUTH.# 31333
Alpha Roofing & Sheet Metal, LLC April 22, 2019
1477 West Gore Street RE-19-086-401aoc
Orlando, Florida 32805
Re: In -Progress & Final Roof Inspections
401 Central Park Drive
Sanford, FL 32771
Permit# BC19-000157
Letter of Compliance
This correspondence is in reference to the recently installed TPO roof system located at 401 Central Park Drive in
Sanford, Florida. The above referenced installation was done on an existing standing seam metal roof deck using a GAF
60-mil TPO roof system. Evaluation of the roof criteria and installation was done by an examination of photographs
obtained from Alpha Roofing & Sheet Metal, LLC.
The existing roof deck consisted of a standing seam metal roof deck, supported by 16 gauge steel purlins spaced at 60"
o.c. The recover roof fastening system was designated to be a GAF 60-mil TPO RhinoBonded onto the mechanically
fastened insulation plates, as per Florida Product Approval. #5293 Page 98, System No. R-182. This system has a
Design Pressure of -45 psf, which exceeds the Field Pressure of -28.3 psf. The maximum roof uplift pressure was P3
Corner at -71.5 psf. Based upon this criteria; the Florida Approval calls for preliminarily fastening the flute fill &
insulation using 6 fasteners per board and subsequently fastening 12.0" o.c. along the 16 gauge purlins in the Field Zone.
Enhancements are required within the Perimeter & Corner Zones.
Using a GAF fastening pattern recommendation, the spacing along the 16 gauge purlins was decreased to 6.0" o.c. in
both the Perimeter & Corner Zones. The insulation was preliminarily attached using Drill-Tec 912 screws w/plates and
secured into the purlins with Drill-Tec Purlin Fasteners and RhinoBond XHD Plates. The 60-mil GAF TPO was
subsequently RhinoBonded onto the insulation plates with a RhinoBond portable bonding tool.
Based upon examination of the photographs obtained from Alpha Roofing and the wind uplift pressure calculations; it is
evident that the roofing system is installed as per the above -referenced Florida Product Approval, and therefore is
acceptable. Note that the perimeter and corner enhancements recommended by GAF actually exceed the calculated
requirements, resulting in additional strength to the roof system. All wind uplift pressures and fastening patterns for the
perimeter and corner enhancements were calculated and verified by RE-CSI.
RE-CSI will continue to provide consulting services upon request. If further assistance is required, or questions arise
concerning this letter, please do not hesitate to contact this office.
Respectfully Submitted, Digitally
signed by
i; Donald J Flood
Donald J. Flood, P.E. t.` ' Date:
Florida Registration #44847 19 23
13:032
Attachments: 1) Selected Photographs 04'00' 2) Wind Uplift Calculations
cc. file 1
RE-CSI
1522 NW 113 Terrace, Pembroke Pines, FL 33026
don@re-csi.net
2.E-CSI
ROOT ENGINIZIUNG C LC' LATIOA SERITCL LW.
FL.CERT. OF AUTH.# 31333
Alpha Roofing & Sheet Metal, LLC
1477 West Gore Street
Orlando, Florida 32805
Re: In -Progress & Final Roof Inspections
401 Central Park Drive
Sanford, FL 32771
Permit# BC19-000157
April 22, 2019
RE-19-086-401-ion
I) EXISTING STANDING SEAM METAL ROOF
2) PRELIMINARY FASTENING, PURUN FASTENERS, TPO
2
RE-CSI
1522 NW 113 Terrace, Pembroke Pines, FL 33026
don(&re-csi.net
RE-CS1
IR gtoo ;I9y F3 fG e.G tt I7loaf s tirc arc.
FL.CERT. OF AUTH.# 31333
Alpha Roofing & Sheet Metal, LLC
1477 West Gore Street
Orlando, Florida 32805
Re: In -Progress & Final Roof Inspections
401 Central Park Drive
Sanford, FL 32771
Permit# BC19-000157
April 22, 2019
RE-19-086-401-toy
3) PRELIMINARY FASTENING, PURLIN FASTENLRS, TP0
3
RE-CSI
1522 NW 113 Terrace, Pembroke Pines, FL 33026
don@re-csi.net
RE—CSl
FL.CERT. OF AUTH.# 31333
Alpha Roofing & Sheet Metal, LLC
1477 West Gore Street
Orlando, Florida 32805
Re: In -Progress & Final Roof Inspections
401 Central Park Drive
Sanford, FL 32771
Permit# BC19-000157
3) OVERVIEW DURING TPO INSTALLATION
4
RE-CS1
1522 NW 113 Terrace, Pembroke Pines, FL 33026
donCa re-csi.net
i i f i
l a• _I
r
April 22, 2019
RE-19-086-40t-loc
R E-CS.I i i i •
L _I
TLOO T EMBVZ1U ING C.RLCK-USl`F2N SU"YIC- MC.
FL.CERT. OF AUTH.# 31333
Alpha Roofmg & Sheet Metal, LLC April 22, 2019
1477 West Gore Street RE-19-086-401-toc
Orlando, Florida 32805
Re: In -Progress & Final Roof Inspections
401 Central Park Drive
Sanford, FL 32771
Permit# BC19-000157
5) TPO, INSULATION, METAL ROOF
5
RE-CS1
1522 NW 113 Terrace, Pembroke Pines, FL 33026
don@re-csi.net
e
III 'T Px Y• ,,.- -
Ero
F.,yYlk^ .. _,. .--,......qti w3e
m.
I!
Vw
C:-* , '
o
s..iE
y!,
F,+i
1
i-