HomeMy WebLinkAbout1810 Rinehart Rd (a) 18-1702 (a)3 0 0 0 00 N c 0 E U 0 0 c 0 U L y c 0 U t g c 0 cc c E U O 0 J LL -o 0 C cu U) LO 0 CIDr m a g N ci E c LL 0 Ni 0 a a" m ca 0 0 a. ARCHITECT r1) design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 ALTITUDE TRAMPOLINE PARK FAX: (781) 875-3039 www.phasezerodesign.00m CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 1810 RINEHART ROAD PHONE: (813) 838-8896 i ELECTRICAL ENGINEER r i SANFORD, FL 32771 -VRAM P Ll N E ISSUED FOR PERMIT/BID DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 MECHANICAL & 1431 GREENWAY DRIVE IRVING, TX 75038 OWNER ARCHITECT STRUCTURAL PLUMBING ELECTRICAL PHONE: (972) 870-1288 STRUCTURAL ENGINEER JUMP 2018 LLC PHASE ZERO DESIGN, INC. ZABIK TURNER ENGINEERING ID STUDIO 4 DON PENN CONSULTING ENGINEER NG ZABIK TURNER ENGINEERING 10108 EVERGREEN LANE DRIVE 35 POND PARK ROAD, BAY 16 1024 N. FULLERS CROSS ROAD 1431 GREENWAY DRIVE 1301 SOLANA BLVD. TAMPA, FL 33647 HINGHAM, MA 02043 WINTER GARDEN, FL JENNIFER ZABIK, PE, SE RI 34787 IRVING, TX 75038 BLDG. 1, SUITE 1420 1024 N FULLERS CROSS ROAD PHONE: (813) 838-8896 PHONE: (781) 452-7121 PHONE: (407) 864-8120 PHONE: (972) 870-1288 WESTLAKE, TX 76262 WINTER GARDEN, FL 34787 CONTACT: BRIAN DUNLEAVY CONTACT: ROBYN KIERNAN CONTACT: JENNIFER ZABIK, PE, SE CONTACT: BRIAN CHANDLER PHONE: (817) 410-2858 PHONE: (407) 864-8120 E-MAIL: bdl6.altitude@gmail.com E-MAIL: rkiernan@phasezerodesign•com E-MAIL: jzabik@ztengineering.com E-MAIL: brianc@idstudio4.com FAX: (817) 251-8411 0 0 � m J 1. ALL WORK SHALL CONFORM TO FEDERAL, STATE AND MUNICIPAL CODES AND ORDINANCES. THESE Q w A A. B. ANCHOR BOLT FAB FACE BRICK P PARD. PARTICLE BOARD P, PARALLEL SHALL SUPERSEDE DRAWINGS, NOTES AND DIMENSIONS IN ALL CASES. THE ARCHITECT SHALL BE CL ABV ABOVE A/C AIR CONDITIONING F.B.O. FURNISHED BY OTHERS PCC. PRECAST CONCRETE NOTIFIED OF SUCH CHANGES BEFORE WORK IS STARTED. CONTRACTOR SHALL OBTAIN PERMITS cc x O O ao ACC ACCESS f. D. FLOOR DRAIN P. E. PORCELAIN ENAMEL BEFORE STARTING WORK, AND OBTAIN APPROVALS OF ALL REGULATORY AGENCIES UPON w N w N A.C.T. ACOUSTICAL TILE OR F. E. FIRE EXTINGUISHER PED PEDESTAL (SINK) COMPLETION, AND AS REQUIRED LAYOUT ROOM NAME N AFF ABOVE FINISH FLOOR f. F. FINISH FLOOR PERI PERIMETER EL: 0'-0" POINT Luo o A.D. AREA DRAIN F.G. FIXED GLASS PKG PARKING ADD ADDENDUM FGL FIBERGLASS 2. THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS, GENERAL CONDITIONS OF THE CONTRACT A. F. F. Ln r) U) I ADH ADHESIVE FIN FINISH PLLAM. PLASTIC LAMINATE 003 ISSUE HISTORY: _ 0 0 ADJ ADJUSTABLE FLG FLASHING FOR CONSTRUCTION, OWNER -CONTRACTOR AGREEMENTS AND ALL ADDENDA ISSUED PRIOR TO AND GENERAL PNL PLASTER AGG AGGREGATE FUR FLOOR PNL PANEL ALL PLAN CHANGES ISSUED AFTER EXECUTION OF THE CONTRACT. N ROOM NUMBER G001 TITLE SHEET, ABBREVIATIONS, SYMBOLS AND GENERAL NOTES • • A.H.U. AIR HANDLING UNIT FN R FENCEESCENT PNT PAINT HEIGHT DATUM ALT ALTERNATE ALUM ALUMINUM FND FOUNDATION PR PAIR 0 G002 EGRESS PLAN AND CODE REVIEW • A.P. ACCESS PANEL F.O.S FACE OF STUD PREFAB PREFABRICATED 3. UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING NOT IN CONTRACT W E A-000 AFX APPROXIMATE FP FIRE PROOF PSF POUNDS PER SQUARE FOOT (N.I.C.) OR EXISTING; ALL ITEMS, MATERIALS AND INSTALLATION OF SAME ARE A PART OF THE ARCHITECTURAL a PSI POUNDS PER SQUARE INCH ARCH. ARCHITECTURAL) FPHB FIRE PROOF HOSE BIBS CONTRACT DEFINED BY THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL PROVIDE AND 0 DOOR NUMBER ASPH ASPHALT FP FIREPLACE PTN PARTITION S A.T. ASPHALT TILE FR FRAME P.T. PRESSURE TREATED INSTALL ALL ACCESSORIES, COMPONENTS AND ASSEMBLIES REQUIRED FOR THE WORK SHOWN. A000 A101 FLOOR PLAN • • AUTO. AUTOMATIC FS FULL SIZE PV PAVE(D) OR PAVING SEE DOOR SCHEDULE AVG AVERAGE FTG FOOTING PVC POLYVINYL CHLORIDE (PIPE) INTERIOR ELEVATIONS A111 REFLECTED CEILING PLAN • AWNG AWNING FUR FURRED(ING) FWD PLYWOOD 4. GENERAL CONTRACTOR SHALL SUBMIT A DETAILED PROJECT SCHEDULE AND IS SOLELY RESPONSIBLE � • A131 FINISH PLAN • F.V. FIELD VERIFY FOR CONSTRUCTION SEQUENCING, METHODS AND TECHNIQUES. 0 , 0 BE) 3O WIDE BASE CAB. A201 EXTERIOR ELEVATIONS • Z Q GGA GAUGE Q Q.T. QUARRY TILE A-0� ` CENTER LINE BOARD GWB. GYPSUM WALL BOARD Q 5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PAYING FOR AND OBTAINING ALL PERMITS, ` O BF BI -FOLD (DOOR) G.C. GENERAL CONTRACTOR R RISER • � O A301 PLATFORM AND RAILINGS PLAN • BIT. BITUMINOUS [� INSPECTIONS, REQUIRED TESTS AND UTILITY CONNECTIONS, TERMINATIONS AND CAPPING UNLESS BLKG BLOCKING GD GRADE OR GRADING , ` R/A RETURN AIR DETAIL MARKSOff, A302 PLATFORM STAIR AND RAMP DETAILS BLDG BUILDING • G.D.O. GARAGE DOOR OPENER R.B. RUBBER BASE OTHERWISE NOTED. 1 I - WINDOW NUMBER A303 PLATFORM ELEVATIONS • O J GFI GROUND FAULT INTERRUPTER RAD RADIUS BLK BLOCK (CMUs) GL GLASS OR GLAZING RBL RUBBLE BMG 13EAMKING GL.BA401 RESTROOM DETAILS -MULTI STALL •K. GLASS BLOCK R.D. ROOF DRAIN 6. GENERAL CONTRACTOR SHALL PROVIDE AND IS SOLELY RESPONSIBLE FOR PUBLIC AND EMPLOYEE KEYNOTE Q B.M. BENCH MARK G.I. GALVANIZED IRON REF REFRIGERATOR PROTECTION AS NECESSARY AND AS REQUIRED BY THE CODES, ORDINANCES AND REGULATIONS OF 0 FINISH KEY A402 RESTROOM DETAILS - FAMILY • Ir Q 0 BP BI -PASS (DOOR) GT GROUT REQ REQUIRED GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT PLACE. RES A000 A501 INTERIOR DETAILS - FRONT DESK • 2 O BRG BEARING H HIGH RESILIENT 1 A502 INTERIOR DETAILS - CONCESSIONS • BRK BRICK H HB HOSE BIBB REV REVISION, REVISED W B.S. BOTH SIDES H.C. HOLLOW CORE KEINE REINFORCED(ING) 7. ANY WORK INVOLVING ALTERATIONS TO EXISTING BUILDING UTILITIES & WHICH REQUIRE UTILITY SHUT BSMT BASEMENT RFG ROOFING ELEVATIONS A503 INTERIOR DETAILS - BREAKROOM • Z Z HD HEAD OR HARD DOWN, SHALL BE COORDINATED WITH THE OWNER AND SHALL REQUIRE A MINIMUM OF 5 FIVE DAYS BOT BOTTOM H.D. HEAT DETECTOR OR HEAVY DUTY R.J.B. REINFORCED JUNCTION BOX () BVL BETWEEN HDR HEADER RLG RAILING NOTICE. ALL FIRE WATCHES &SECURITY REQUIREMENTS SHALL BE G.C. A504 MEZZANINE & STAIR DETAILS • Q BVL BEVELED HDW HARDWARE RSM RANGE W/ MICROWAVE B.W. BOTH WAYS HT HEIGHT RWL ROOF WATER LEADER WALL FINISH A601 SCHEDULES AND DETAILS • H.M. HOLLOW METAL R.O. ROUGH OPENING 8. IN THE EVENT OF DISCREPANCIES IN THE DRAWINGS, THE COSTLIER OR MORE RESTRICTIVE A - �■ U) C CAB CABINET HORZ HORIZONTAL R.O.W. RIGHT OF WAY CONDITIONS SHALL BE DEEMED THE CONTRACT REQUIREMENT, UNLESS OTHERWISE STATED IN 0 FLOOR FINISH C. 5. CATCH BASIN 0 HR HOUR RAS ROD AND SHELF(S) WRITING, FROM THE OWNER OR OWNER'S REPRESENTATIVE. ANY DISCREPANCIES SHOULD A-000 BASE FINISH STRUCTURAL Lu Ir - CEM CEMENT H. R. HALF ROUND SC SOLID CORE IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. REVISION CLOUD L1.00 FRAMING PLAN • r CER CERAMIC HS HORIZONTAL SLIDER S SCh SCHEDULE SECTION CUT & TAG WAINSCOTTING L2.00 DETAILS • CF CUBIC FOOT HTG HEATING CRAM CHAMFER HVAC HEATING/VENTILATING/AIR COND. SD SMOKE DETECTOR COLUMN REFERENCE C. 1. CAST IRON HWD HARDWOOD SEC SECTION 9. GENERAL CONTRACTOR SHALL WARRANT WORK PERFORMED FOR A PERIOD OF ONE YEAR FROM THE L3.00 DETAILS • C.I.P. CONC.CAST-IN-PLACE CONC. 5. F. SQUARE FEET DATE OF FINAL ACCEPTANCE. CIR CIRCLE I.B. IRONING BOARD SF.GL. SAFETY GLASS XXX ROOM TAG CIRC CIRCUMFERENCE I I.D. INSIDE DIAMETER S.G.D. SLIDING GLASS DOOR PLUMBING C.J. CONTROL JOINT I.L.O. IN LIEU OF SH SINGLE HUNG OR SHELF 10. VERIFY DIMENSIONS AND JOB CONDITIONS PRIOR TO SUBMITTING BIDS, AND REPORT TO THE 0 CK CALK(ING) CAULK(ING) I.M. INSULATED METAL SHT (DRAWING) SHEET ARCHITECT AND OR OWNER DISCREPANCIES WHICH WOULD INTERFERE WITH SATISFACTORYA-000 . �� . �� . P101 PLUMBING PLANS • CL CLOSET OR CENTER LINE INS/INSUL INSULATED(TION) SHTHG SHEATHING INT INTERIOR SIM SIMILAR COMPLETION OF THE WORK. DO NOT SCALE THE DRAWINGS. DIRECTION MATCH LINE &NOTE P201 PLUMBING SCHEDULES &DETAILS • CUR CEEARGANCE) SKL SKYLIGHT ARROW XXX XXX CEILING MATERIAL CLS CLOSURE OR CLOSER JST JOIST SL SIDELIGHT OR SLEEVE 11, IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO KEEP THE PREMISES CLEAN OF X XXX CEILING FINISH CM CENTIMETERS) , JT JOINT SNC SEALANT MECHANICAL CMU CONCRETE MASONRY UNIT SPC SPACER DEBRIS, RUBBISH, EXCESS MATERIALS, ETC. RESULTING FROM THE WORK OF THIS CONTRACT. C.O. CASED OPENING KD KNOCKDOWN SPEC SPECIFICATIONS TENANT SPACE SHALL BE BROOM CLEAN EACH WORK DAY. 0 M101 MECHANICAL PLAN • COL COLUMN K KIT KITCHEN SPK SPEAKER COMB COMBINATION KO KNOCKOUT S.ST. STAINLESS STEEL x000 M201 MECHANICAL SCHEDULES & DETAILS • CONC CONCRETE KPL KICKPLATE STD STANDARD 12. CHARGES FOR EXTRA WORK DONE BY THE CONTRACTOR WILL NOT BE HONORED UNLESS THE WORK COND (AC) CONDENSER K/S KNEE SPACE STSTORAGE AND THE AMOUNT ARE AGREED TO BY THE OWNER, OR THEIR AGENT, IN WRITING BEFORE THE WORK CONST CONSTRUCTION STL STEEL BUILDING SECTION ELECTRICAL CONT CONTINUOUS IAM, LAMINATE(D) STR STRUCTURAL IS DONE, BASED UPON UNIT PRICING. CONTR CONTRACTOR L LAV LAVATORY SQ SQUARE E101 LIGHTING FLOOR PLAN • CORK CORRUGATED L.B.O. LOCATION BY OTHERS SUS SUSPENDED • CPR COPPER LIV LIVING S.W. SHEAR WALL 13. AS REQUIRED BY CODE, EACH CONTRACTOR AND EACH SUBCONTRACTOR SHALL OBTAIN REQUIRED E102 POWER PLAN C/CPT CARPET L.L. LIVE LOAD INSPECTION OF THAT PORTION OF WORK. CRs COURSE(S) L. P. LAMINATED PLASTIC T T TREAD E201 ELECTRICAL DETAILS • CSMT CASEMENT T. 5. TOWEL BAR C M CAST STONE LT LIGHT T.B.D. TO BE DETERMINED 14. ALL FIRE -RATED ASSEMBLES SHALL BE INSTALLED, LABELED, AND INSPECTED IN ACCORDANCE WITH E301 ELECTRICAL SCHEDULES & RISER DIAGRAM • C.T. CERAMIC TILE L.T. LAUNDRY TUB TC TERRA COTTA CTR CENTER OR COUNTER LTL LINTEL T.C.J. TROWELED CONTROL JOINT THE APPLICABLE BUILDING CODE WHEN REQUIRED. CX CONNEXTION LVL VENNER LUMBER TEMP. TEMPERED (GLASS) CY CUBIC YARD LVR LOUVER T$G TONGUE t GROOVE 15. CONTRACTOR SHALL PROVIDE FIRE EXTINGUISHERS AS DICTATED BY STATE AND LOCAL BUILDING MTEL TELEPHONE 1 2"D 12" DEEP M MAX MAXIMUM THK THICKNESS) AND SAFETY CODES. COORDINATE WITH OWNER AND OWNER'S REPRESENTATIVE. DRYER, OR DRAIN MAS MASONRY THR THRESHOLD SYMBOL INDEX D w DBL DOUBLEMATL MATERIAL T.O.C. TOP OF CONCRETE TOFTOP OF FOUNDATION 16. COORDINATE AND VERIFY EQUIPMENT SIZES WITH THE OWNER. COORDINATE DIMENSIONS OF o DECO DECORATIVE MC MEDICINE CABINET T. c DEM DEMOLISH, DEMOLITIONMECH MECHANICAL T.O.M. TOP OF MASONRY FURRED AREAS WITH EQUIPMENT AND OWNER FIXTURE REQUIREMENTS. T.O.W. TOP OF WINDOW a DEP DEPRESSED MFR. MANUFACTURER REVISIONS D.F. DRINKING FOUNTAIN TP TOILET PAPER HOLDER REV DATE DESCRIPTION /COMMENTS DET DETAIL MH MANHOLE TR TRANSOM 17. PROVIDE FRT SOLID WOOD BLOCKING BEHIND ALL SPECIALTY MILLWORK, SIGNAGE, AND AWNINGS, DH DOUBLE HUNG MIR MIRROR TV TELEVISION OUTLET ETC. COORDINATE LOCATION OF ALL SUCH WALL ATTACHED ITEMS WITH OWNER OR THEIR AGENT DIAM DIAMETER MISC MISCELLANEOUS Tl F TYPICAL PRIOR TO INSTALLATION OF WOOD BLOCKING. DIM DIMENSION MLD MOULDING UC UNDERCUT D.L. DEAD LOAD MM MILLIMETER U UNF UNFINISHED DN DOWN MMB MMB MEMBRANE U.N.O. UNLESS NOTED OTHERWISE 18. ALL REQUESTS FOR PAYMENT SHALL BE MADE WITH THE USE OF THE AIA APPLICATION FOR PAYMENT D.P. DAMP -PROOFING M.O. MASONRY OPENING DR DOOR AND PROVIDED TO THE OWNER'S REPRESENTATIVE FOR REVIEW AND RECOMMENDATION TO THE MOD MODULAR . VB VANITY BASE OWNER. DRY DRYER MACHINE MRB MARBLE DS DOWNSPOUT V V. B. VAPOR BARRIER METAL D/S DRAWER STACK MTL MO NTED(ING) VB# VANITY BASE WIDTH D.T. DRAIN TILEMULL MULLION OR MULLED VERT VERTICAL 21. PROTECTION OF WORK: HOISTING, UNLOADING AND DELIVERIES, TRASH &DEBRIS REMOVAL, AND DTL DETAIL VIN VINYL(SHEET) DISPOSAL OF ALL WASTE, MUST BE COORDINATED WITH BASE BUILDING, DOCK MANAGER & CITY DW DISH WASHER N.A. NOT APPLICABLE V.S. VEGTABLE SINK DWG DRAWING N N.I.C. NOT IN CONTRACT V.C.T. VINYL COMPOSITION TILE POLICE. DWR DRAWER NL NAIL.ABLE W ## WALL CAB DIMENSIONS NOM NOMINAL 22. ALL LIGHT GAUGE METAL FRAMING SHALL BE PREPARED AND STAMPED UNDER THE SUPERVISION OF E EA EACH N.T.S. NOT TO SCALE W WIDE OR WASHING MACHINE EB EYEBROW N.G.V.D. NAT. GEODETIC VERTICAL DATOM WC WATER CLOSET A QUALIFIED ENGINEER LICENSED IN THE JURISDICTION OF THE PROJECT. SEAL E.F. EACH FACE WD WOOD E.J. EXPANSION JOINT OA OVERALL WF WIDE FLANGE EL ELEVATION O OBS OBSCURE (GLASS) WH WATER HEATER 23. PATCHING OF HOLES IN EXISTING CONSTRUCTION - PATCH AND REPAIR HOLES AS NECESSARY TO ELEC ELECTRIC(AL) O.C. ON CENTER W.H. WALL HUNG E.P. ELECTRICAL PANEL OHC OVERHEAD CABINET WI WROUGHT IRON MATCH ADJACENT CONSTRUCTION AND TO MAINTAIN THE FIRE RATING OF THE ASSEMBLIES. EQ EQUAL 0. D. OUTSIDE DIAMETER WIC WALK-IN CLOSET FIRESTOPPING SYSTEM MAY BE USED TO FILL HOLES THAT WILL BE CONCEALED IN THE FINISH EST ESTIMATE O O.G.D. OVERHEAD GARAGE DOOR WIN WINDOW CONSTRUCTION. E.W.C. ELECTRIC WATER COOLER OH OVERHEAD W/W/O WITH OR WITHOUT EXG EXISTING OPNG OPENING WP WATERPROOF OPT OPTIONAL EXT EXHAUST W.R. WATER RESISTANT EXT EXTERIOR OSB ORIENTED STRAND BOARD QUALITY CONTROL: WSCT WAINSCOT �ENER W.T.W. WALL TO WALL WWM WELDED WIRE MESH A. SITE MEETINGS: CONTRACTOR TO CONDUCT SITE MEETINGS AND WRITE MEETING MINUTES AT FREQUENCY AS DIRECTED BY OWNER, UNLESS OTHERWISE DIRECTED BY OWNER OR OWNER'S REPRESENTATIVE. CONTRACTOR AND ALL SUB -CONTRACTORS MUST BE PRESENT, UNLESS WAIVED LOCUS PLAN BY OWNER. B. INSTALLATION: EXCEPT AS MORE STRINGENT REQUIREMENTS ARE INDICATED ON THESE DRAWINGS AND IN THESE NOTES, COMPLY WITH GENERALLY ACCEPTED INDUSTRY STANDARDS AND INSTALL ,,,.,. n fi . PRODUCTS IN STRICT COMPLIANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS.`"' k: ,� fi' ISSUED FOR: PERMIT - BID f= G ISSUED DATE: 04.04.2018 C. WHEN EVALUATING APPEARANCE OR CONFORMANCE WITH DESIGN INTENT, THE WORDS#.3 {„ ,• , "ACCEPTABLE", "VISIBLE", "INVISIBLE", "MATCHING", "ALIGNED", AND SIMILAR TERMS OF JUDGMENT DRAWN BY: EJL � �{ .e SHALL MEAN "ACCEPTABLE, ETC., IN THE OPINION OF THE ARCHITECT OR OWNER", : I I L ., CHECKED BY. RK r �I PROJECT NUMBER: 2118015 L - N Copyright (o) by Phase Zero Design Corp AR Rights ,, ��� I � � � . Mt • .'" * DRAWING NAME �r 4 � ' TITLE SHEET, i ? ?�� ABBREVIATIONS, SYMBOLS & ;y t . _ GENERAL NOTES �!+ DRAWING N0. wf ,! k Al - ABBREVIATIONS GENERAL NOTES VICINITY MAPINDEX OF DRAWINGS G001 C4 0 r t� 3 0 LO 0 00 c m I M 0 c to O 00 a g E cc U- m 0 ca N N a 0 6 a a o i 111 EGRESS PLAN SCALE: 3/32 "=1'-0" FE STORAGE I a 114 EGRESS DISTANCE: 106'-6" ---------------------�----- ----- -- M 0 M F E (:D C 24'-11 " 43' -Il" 43'-11" \ 43'-11" SECONDARY EXIT WIDTH: 34" I L I SECONDARY 0 EXIT WIDTH: 32" it EGRESS PLAN SCALE: 1/8"=l' -O" TORAC�E 113 0 45'-0" AAA A 5'-6" V-0" I I i I- ------- --------7>---------�-�"F_ I I I I EGRPSS DITNC�E:213'-4" I Lill rl I I I I (}--4-----4--� n n o v� 17 0 0� 10 io c Fl= o � PARTY PARTY PARTY ARCHITECT ROOM EGRESS PLAN LEGEND PROJECT DESCRIPTION: 111 110 �— TRAVEL PATH THE DRAWINGS AND SPECIFICATIONS DEFINED HEREIN REPRESENT THE SCOPE OF WORK FOR THE FIT -OUT OF A 30,100 SF MIXED USE SPACE, WITH EXERCISE AND ASSEMBLY AREAS, design • MOST REMOTE POINT BUSINESS AND STORAGE. 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 EXISTING BUILDING CONSTRUCTION: PHONE: (781) 452-7121 TYPE OF EXIT FAX: {781875-.30139 STRUCTURE: STEEL COLUMNS CLIENT FE FIRE EXTINGUISHER FOUNDATION: SLAB ON GRADE. WALLS: METAL STUDS ROOF: STEEL JOISTS AND BEAMS WITH JUMP 2018 LLC METAL DECKING. 10108 EVERGREEN LANE DRIVE \ TAMPA, FL 33647 PHONE: (813) 838-8896 5 D1 l 75' (RADIUS) DISTANCE TO FIRE EXTINGUISHER BUILDING DESIGN CRITERIA: F E (:D C 24'-11 " 43' -Il" 43'-11" \ 43'-11" SECONDARY EXIT WIDTH: 34" I L I SECONDARY 0 EXIT WIDTH: 32" it EGRESS PLAN SCALE: 1/8"=l' -O" TORAC�E 113 0 45'-0" AAA A 5'-6" V-0" I I i I- ------- --------7>---------�-�"F_ I I I I EGRPSS DITNC�E:213'-4" I Lill rl I I I I (}--4-----4--� n n o v� 17 0 0� 10 io c Fl= o � PARTY PARTY PARTY ROOM ROOM ROOM 112 111 110 PARTY PREP KITCHEN \ jos STORAGE WOMEN'S MEN'S 108 RESTROOM RESTROOM 107 106 FAMILY RESTROOM 105 I -OF ICE 102 =JA ITOR'S CLOSET 104 - BR AKROO 103 I � X w= >- M Za 03: 0 N CONSTRUCTION CLASSIFICATION: 2B OCCUPANCY USE: ASSEMBLY (A3) , BUSINESS (B) ELECTRICAL ENGINEER STORAGE (S-1) MIXED-USE REQUIREMENTS: N/A MAXIMUM TRAVEL DISTANCE: 250 FT - SPRINKLERED EXIT DOOR REMOTENESS THE EXIT DOORS OR EXIT ACCESS DOORWAYS ARE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED. DIAGONAL DISTANCE = 257'-5" 13 = 85'-10". ACTUAL DOOR REMOTENESS =183'-7". DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. EXIT ACCESS BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 LENGTH OF MAX. TRAVEL DISTANCE (SPRINKLERED): 151'-2" O 817.410.28581 F 817.251.8411 COMMON PATH OF TRAVEL 75' MAX FLORIDA ENGINEER NO. 0051096 (MECH) � DEAD ENDS: 20' MAX FIRE RESISTANCE RATINGS (HOURS) ASSEMBLY / OPENING MECHANICAL 8 PLUMBING ENGINEER STRUCTURAL FRAME 0 NA IDSTUDIO4 BEARING WALLS (EXTERIOR) 0 NA 1431 GREENWAY DRIVE BEARING WALLS (INTERIOR) 0 NA IRVING, TX 75038 ROOF CONSTRUCTION 0 NA PHONE: (972) 870-1288 EXIT ACCESS CORRIDORS 0 NA OCCUPANCY SEPARATIONS B / M 0 NA STRUCTURAL ENGINEER 0 HOURS WITH SPRINKLER SYSTEM NOT LESS THAN 1 HOUR PER NFPA 101 - 2009 ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE EGRESS DOORS ANALYSIS 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 TOTAL OCCUPANTS = 605 OCCUPANTS PHONE: (407) 864-8120 TOTAL DOOR CLEAR EGRESS WIDTH REQ'D = 605 OCC. x.15 IN/OCC. =90.75 IN TOTAL DOOR EGRESS PROVIDED =181 IN EGRESS WIDTH EGRESS EXITS REQ'D =3 1.5 NUMBER OF EGRESS EXITS PROVIDED =4 APPLICABLE CODES BUILDING CODE 2017 FLORIDA BUILDING CODE PLUMBING CODE 2017 FLORIDA BUILDING CODE - PLUMBING 1.8 MECHANICAL CODE 2017 FLORIDA BUILDING CODE - MECHANICAL ELECTRIC CODE 2014 NATIONAL ELECTRIC COMPANY (NEC) Q o FIRE/LIFE & SAFETY 2017 FLORIDA FIRE PREVENTION CODE w ACCESSIBILITY CODE 2017 FLORIDA BUILDING CODE - ACCESSIBILITY � Q 2,4 ENERGY CODE 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION w J COMPLIANCE O LL DESIGN DATA 0. Q \ _ TENANT FOOTPRINT 30,100 SF (GROSS) W O \ Z BUILDING HEIGHT SINGLE STORY / @ 24'-0" O CONSTRUCTION TYPE 2B W po OCCUPANCY CLASS MIXED: (A3) ASSEMBLY / (B) BUSINESS / STORAGE 2.6 OCCUPANT LOAD 605 OCCUPANTS REQUIRED SPRINKLER YES OR ALARM SYSTEM REQUIRED TENANT YES 3 SEPARATIONS OCCUPANCY CALCULATIONS (NET SF) 3.4 SPACE SIZE OF SPACE (SF) OCCUPANT CALC # OF OCCUPANTS RECREATION/ 24,670 1/50 494 TRAMPOLINE AREA ASSEMBLY/ PARTY 1,327 1/15 89 AREA BUSINESS/ w OFFICE/BREAK 1,410 1/100 15 z CL STORAGE/ REVISIONS 1 LOADING/ELEC. ,928 1 / 300 7 REV DATE DESCRIPTION I COMMENTS 3.7 MEZZANINE 918 1/300 4 STORAGE TOTAL 29,336 605 PER SF PLUMBING FIXTURES WATER CLOSETS LAVATORIES SEAL REQUIRED PROVIDED REQUIRED PROVIDED MALE (ASSUMED 303) 3 (1 PER 125) 4 2 (1 PER 200) 2 - FEMALE (ASSUMED 303) 5 (1 PER 65) 4 2 (1 PER 200) 2 FAMILY PLUMBING FIXTURES DRINKING FOUNTAIN SERVICE SINK REQUIRED PROVIDED REQUIRED PROVIDED ISSUED FOR: PERMIT -BID 1 PER 500 2 1 1 ISSUED DATE: 04.04.2018 DRAWN BY: KH CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. AN Rights Reserved. DRAWING NAME EGRESS PLAN 5 AND CODE REVIEW NOTES DRAWING NO. 0002 IJ 2 4'� FLOOR PLAN - MEZZANINE SCALE: 1/8"=1'-0" rF CE CD CC' B A. 4 A.2 (/A 24'-11" 43'-11" 43'-11" 43'-11" 45'-0" 5'-6" r"/1PC I T J 1 ur%mVC VVVIVICIV J IVICIV J I-AIVIILT ROOM ROOM ROOM PREP KITCHEN 108 RESTROOM RESTROOM RESTROOM 112 111 110 109 107 106 105 _ co OP N in Lo _ N r 1� 1.8 0 N 4 1— 5� GENERAL NOTES: 1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS. IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE CONSTRUCTION MANAGER. 2. VERIFY SIZE, LOCATION, AND CHARACTERISTICS, OF ALL WORK AND EQUIPMENT TO BE FURNISHED BY OWNER OF OTHERS, WITH THE MANUFACTURER OR SUPPLIER BEFORE ANY CONSTRUCTION PERTAINING TO SAME IS BEGUN. 3. ALL DIMENSIONS ON PLANS ARE TO FACE OF FINISHED WALL (GWB) UNLESS OTHERWISE NOTED. 4. FIRE EXTINGUISHER: 10 CLASS ABC WITH UL RATING 4A-60BC. SURFACE MOUNTED ON WALL WITH MANUFACTURERS ALL STEEL WALL BRACKET. FIRE EXTINGUISHERS TO BE MOUNTED TO WALL OR EXISTING COLUMNS. REFER TO G002 FOR PLACEMENT. FIRE EXTINGUISHERS TO BE'LARSEN MP10'. 5. ALL WORK SHALL BE IN COMPLIANCE FEDERAL, STATE AND LOCAL BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS. 6. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. 7. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. 8. THE G.C. SHALL ACQUAINT HIMSELF WITH THE BARRIER FREE REQUIREMENTS FOR THE STATE OF FLORIDA AND THE AMERICAN DISABILITIES ACT (ADA) AND SHALL INSURE THAT THIS SPACE WILL BE ACCESSIBLE ACCORDING TO THE STRICTER REQUIREMENTS OF THE APPLICABLE STANDARDS. 9. PATCH AND REPAIR ALL WALLS AND FLOORS AS NEEDED TO RECEIVE NEW FINISHES. 10. ALL DOORS ARE LOCATED 5" FROM ADJACENT WALL U.N.O. 11. ALL PARTITIONS ARE TYPE'Ai' U.N.O. REFER TO PARTITION TYPES ON A601. FLOOR PLAN LEGEND OWINDOW NUMBER TAG (SEE 2/A601) XXXX DOOR NUMBER TAG (SEE SHEET A601) OPERFORMANCE NEW PARTITION ----- LINE ABOVE ❑A --- WALL TYPE (SEE 3/A601) FLOOR PLAN KEY NOTES: OWARPED WALL 8', 10' & 12' AND AIR BAG. OCARDIO WALL OPERFORMANCE AREA OMAIN TRAMPOLINE PARK OFOAM PIT OTRAPEZE BAR ODODGE BALL COURT OKIDS COURT OROCK WALL / LOG ROLL / MONKEY BARS 10 BASKETBALL COURT 11 WIPE OUT 2 <4> EVENT NETTING BY TRAMPOLINE VENDOR 13 ELEVATED FEATURE AROUND EXISTING COLUMN 14 SEATING BENCH 16" AND SHOE CUBBY. REFER TO DETAIL ON A/502 15 CONCESSION MILLWORK. REFER TO DETAILS ON A501 6 <4> ALIGN NEW WALL WITH EXISTING WALL CORNER 17 ALIGN NEW WALL WITH EXISTING WALL 8 <4> WALL MOUNTED LCD F/I BY TENANT, TO BE MOUNTED 6'-0" AFF <19> 9 NEW WATER FOUNTAIN. REFER TO PLUMBING DRAWINGS 0 <4> FRONT DESK MILLWORK. REFER TO DETAILS ON A501. 21 WAIVER DESK MILLWORK. REFER TO DETAILS ON A502. 2 <4> ICEE MACHINE. FURNISHED AND INSTALLED BY TENANT. 23 FURNITURE FURNISHED AND INSTALLED BY TENANT. 4 <4> NEW MEZZANINE. SEE SHEET A504 FOR MORE INFO. 5 <4> G.C. TO RE -KEY EXISTING DOOR TO MATCH NEW DOOR. 6 <4> ELEVATED PLATFORM. 7 <27> COLUMN MOUNTED LCD F/I BY TENANT, TO BE MOUNTED 9'-0" AFF. 8 <4> NEW STAIR TO MEZZANINE. SEE SHEET A504 FOR MORE INFO. GRAPHIC LEGEND ELEVATED PLATFORM - 35.6875" A.F.F. F__1 ELEVATED PLATFORM - 61.6875" A.F.F. Q2'-0" HIGH ELEVATED PLATFORM ABOVE JUMPING MAT ARCHITECT 0 Imm 0 design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phaodesgn.aom CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 1 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 U W K a SEAL a / /COMMENTS ISSUED FOR: PF1 MIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: KH CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. AR Rights Reserved. DRAWING NAME FLOOR PLAN DRAWING NO. o,� FLOOR PLAN - GROUND FLOOR Al 01 a SCALE: 1/8"=1'-0" NOTES & LEGEND 3 a Q LO CD DO rn C d E U O O C O U 2 c O s g c 0 c E U O O J U- 0 c m LO 0 00 r m 3 g Q' ci E c U- ` 3 0 v 0 a N N N 0 0 n - F/ N rE _I 2 REFLECTED CEILING PLAN - MEZZANINE SCALE: 1/8"=V-0" 15'-1y4" 15'-6" 15'-6" 1 10 1 STORAGE O 0 - 6 114 6>1 5 6 = 3 'D cc 31 SOFFIT DETAIL SCALE: 1 /4"=1'-0" 1.8� 2 1 X24 26 i 4) --loll 7-P N N tV I L _ 11-0.8'-0" 11-011 2'-3- 16'-0" 2'-3- 1 1 0 8'-0" 0 1 I rF E D) C rB CA. CA. (A' 24'-11" 43'-11" 43'-11" 43'-11" 45'-0" 6-6" 1'-0" 1 I N 0 LO 1.5 7 I REFLECTED CEILING PLAN - GROUND FLOOR SCALE: 3/32"=1'-0" •. - � . 1-i-+� 1 r r -/"%r% I >i PARTY 'STORAGE WOMEN'S MEN'S FAMILY ROOM ROOM ROOM PREP KITCHEN 108 RESTROOM RESTROOM RESTROOM 112 111 110 109 107 106 105 —; 5 GENERAL NOTES: 34 1. PLAN FOR LOCATING GRID AND FIXTURE REFERENCE ONLY. REFER TO ELECTRICAL DRAWINGS FOR FIXTURE SPECIFICATIONS AND WIRING. 2. MOUNT LIGHTING TO UNDER SIDE OF STRUCTURE. ADJUST SPACING BETWEEN FIXTURES AS NEEDED. 3. ACT GRID TO BE CENTERED IN EACH ROOM U.N.O. 4. DECK HEIGHT VARIES. G.C. TO ENSURE BOTTOM OF'B' LIGHTS TO ALIGN. REFLECTED CEILING PLAN KEY NOTES: NEW WHITE, 2 X 4 LAY -IN CEILING TILE W/ CEILING GRID TO BE EQUAL TO ARMSTRONG PRELUDE 15/16 OR US GYPSUM ENVIRONMENTAL ZXA GRID SYSTEM. WIDE FACED, 1 ALUMINUM CAPPED, DOUBLE -WEB, HOT DIP, GALVANIZED STEEL, ® INTERMEDIATE -DUTY. WHITE FINISH. TILE TO BE ARMSTRONG OPTIMA SQUARE D TEGULAR 15/16. COLOR: WHITE. O2 EXPOSED ROOF DECK OPEN TO ABOVE, PAINT PT -02 OEXIT SIGNAGE, SEE ELECTRICAL O4 EXISTING GWB CEILING AND LIGHTING TO REMAIN. OEXPOSED ROOF DECK, UNPAINTED ONEW HIGH BAY LIGHT FIXTURE TO BE MOUNTED @ 21'-0" A.F.F. OEXISTING HIGH BAY RAISED TO 21'-0" A.F.F. O8 EXISTING SOFFIT @ 13'-11" TO BE PAINTED PT -01. ONEW HIGH BAY LIGHT FIXTURES TO BE ALIGNED BY CENTERLINE LIGHTING LEGEND 2' X 4' FIXTURE 2' X 4' EMERGENCY FIXTURE HIGH BAY LIGHT FIXTURE ® EMERGENCY EXIT SIGN D STRIP FLUORESCENT LIGHTING NOTES & LEGEND ARCHITECT 00 design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezerodesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL $ PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 NO � 6L LL N� N0 Q Ldp =O W LL /'Z Z ER 0 V�/J'� V11 W Ir - 1 REV I DATE I DESCRIPTION / COMMENTS 1 SEAL ISSUED FOR: PLRMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: KH CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. Ag Rights Reserved. DRAWING NAME REFLECTED CEILING PLAN DRAWING NO. A111 PT -01 STORAGE B-01 114 F-01 �DECK ROOF & STRUCTURE ABOVE 0 co 5� 2 FINISH PLAN -MEZZANINE SCALE: 1/8"=l' -O" F �E CD C rB CA. A.2 CA 24'-11" 43'-11" 43'-11" \ 43'-11" 45'-0" 5'-6" - <2� <3> </ �l 1� 1.� t C4 T 2-6) 1 __�/ 7 I FINISH PLAN SCALE: 1/8"=1'-0" r/"%n I c rP%M I T r/Ar% I T PARTY ' STORAGE WOMEN'S MEN'S FAMILY ROOM ROOM ROOM PREP KITCHEN 108 RESTROOM RESTROOM RESTROOM 112 111 110 109 107 106 105 4 M 0 M 3.� 4� GENERAL NOTES: ARCHITECT 1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS. IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE CONSTRUCTION MANAGER. design 2. VERIFY SIZE, LOCATION, AND CHARACTERISTICS, OF ALL WORK AND EQUIPMENT TO BE 35 POND PARK ROAD, BAY 16 FURNISHED BY OWNER OF OTHERS, WITH THE MANUFACTURER OR SUPPLIER BEFORE ANY HINGHAM, MA 02043 CONSTRUCTION PERTAINING TO SAME IS BEGUN. PHONE: (781) 452-7121 FAX: (781) 875-3039 3. ALL DIMENSIONS ON PLANS ARE TO FACE OF FINISHED WALL (GWB) UNLESS OTHERWISE '"w"phasemodesign.00m NOTED. CLIENT 4. FIRE EXTINGUISHER: 10 CLASS ABC WITH UL RATING 4A-60BC. SURFACE MOUNTED ON WALL JUMP 2018 LLC WITH MANUFACTURERS ALL STEEL WALL BRACKET. JL INDUSTRIES INC. (COSMIC 10E) OR 10108 EVERGREEN LANE DRIVE APPROVED EQUAL WITH INSPECTION TAG AS REQUIRED BY LOCAL CODES. TAMPA, FL 33647 PHONE: (813) 838-8896 5. ALL WORK SHALL BE IN COMPLIANCE FEDERAL, STATE AND LOCAL BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS. ELECTRICAL ENGINEER 6. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. 7. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. 8. THE G.C. SHALL ACQUAINT HIMSELF WITH THE BARRIER FREE REQUIREMENTS FOR THE STATE OF IDAHO AND THE AMERICAN DISABILITIES ACT (ADA) AND SHALL INSURE THAT THIS SPACE WILL BE ACCESSIBLE ACCORDING TO THE STRICTER REQUIREMENTS OF THE APPLICABLE STANDARDS. DON PENN CONSULTING ENGINEER 9. PATCH AND REPAIR ALL WALLS AND FLOORS AS NEEDED TO RECEIVE NEW FINISHES. 1301 SOLANA BLVD. BLDG. 1 1 SUITE 1420 WESTLAKE, TX 76262 10. PAINT ALL EXISTING COLUMNS PT -02 O 817.410.28581 F 817.251.8411 11. PAINT ALL NEW & EXISTING DOOR FRAMES PT -02 FLORIDA ENGINEER NO. 0051096 (MECH) FINISH PLAN KEY NOTES: MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE Oi STANDARD PERIMETER PAINT SCHEME, REFER TO 2/A131 IRVING, TX 75038 PHONE: (972) 870-1288 OMODIFIED PERIMETER PAINT SCHEME. NO PAINT BELOW 9'-0". PAINT PT -03 FROM 9'-0" TO 12'-0', THEN FOLLOW STANDARD SCHEME ABOVE 12'-0". STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING OMODIFIED PERIMETER PAINT SCHEME. NO PAINT BELOW 5'-0". PAINT PT -03 FROM 5'-0" TO 12'-0", THEN FOLLOW STANDARD SCHEME ABOVE 12'-0". JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD 4 EXISTING COLUMNS TO BE PAINTED PT -02 WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 INTERIOR MATERIAL & FINISHES WALL PT -01 SW7004, COLOR: SNOWBOUND, PAINT. PT -O2 SW6258, COLOR: TRICORN BLACK, PAINT. PT -03 SHERWIN WILLIAMS, CUSTOM PURPLE, PAINT. PT -04 SHERWIN WILLIAMS, CUSTOM CYAN, PAINT. PT -05 SW6887, COLOR: NAVEL, PAINT. ODALTILE: LINDEN POINT - GRIGIO 12"x24" #LP21 GROUT: LATICRETE 89 SMOKE GRAY OR EQUAL BASE B-01 JOHNSONITE, RUBBER COVE BASE. COLOR: #40 BLACK, 4" RUBBER BASE. THROUGHOUT SPACE. Z Q FLOOR F-01 V -SEAL 101. ALL EXPOSED FLOORING (NOT UNDER TRAMPOLINES OR PLATFORMS). wj O J O W use. DALTILE LINDEN POINT - GRIGIO 12"x24" #LP21 GROUT: LATICRETE 89 SMOKE GRAY OR EQUAL F— On 29 = O NOT USED W LL -Qi CARPET TILE: FURNISHED BY TRAMPOLINE VENDOR, INSTALLED BY G.C. Z Z Q (n -02 CARPET TILE: PATCRAFT 10379 ORBITAL - COLOR: 00590 ATOMIC, MONOLITHIC PATTERN O W NOTES & SCHEDULES 00 Z w PT -01 U O - 13 I RESTROOM WALL PAINT SCHEME I 1/2"=1'-0" Y w PT -02 0 O I— t PT-03 xlll_ B-01 J �I 2 PERIMETER WALL PAINT SCHEME 1/2"=1'-0" 8 U W O IL IL SEAL ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: KH CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. All Rights Reserved. DRAWING NAME FINISH PLAN DRAWING NO. A1 31 EXTERIOR ELEVATION KEYED NOTES: OEXIST. SIGN TO BE REMOVED. GC TO PATCH AND REPAIR SIGN BAND CONSTRUCTION AS REQ'D OEXIST. BOLLARDS TO REMAIN. G.C. TO PREP TO RECEIVE NEW PAINTED FINISH, PT -02. OEXIST. BOLLARDS TO REMAIN. G.C. TO PREP TO RECEIVE NEW PAINTED FINISH, PT -03. 4O G.C. TO PREP EXTERIOR TO RECEIVE NEW PAINT FINISH, PT -02. OG.C. TO PREP EXIST. BAND TO RECEIVE NEW PAINT FINISH PT -03. OEXIST. STOREFRONT DOORS AND GLAZING TO REMAIN. G.C. TO REPLACE/REPAIR HARDWARE AT DOORS AS REQUIRED. CLEAN ALL GLAZING TO'LIKE NEW' CONDITION. O7 EXIST. EXTERIOR TO REMAIN AS -IS. OEXIST. EXTERIOR TO REMAIN AS -IS. ARCHITECT 10, design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezmdesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG, 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 CL w 0 NOTES W O Z Z � � Q 5 LLI 00 TYP. T.O. PARAPET 44'-4" I ! I I J i i I i ( I I T.O. PILLAR 37'-0" >TYP. ! j ! 4 TYP. i T.O. MASONRY 30'-8" Lu 0 a ! � I � REVISIONS �— REV DATE DESCRIPTION COMMENTS I i � I I I i I 5 8 ( TYP. TYP. Eil8 TYP. SEAL B.O. CANOPY 111111111111111 Jill 1111111111111111111111111111 18'-0" D ❑ [.116 6 6 III I I I 11HR LH11 1111111111111111111111111111111111111111 ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: KLH CHECKED BY: RK 6 6 6 PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. AN Rights ReserveC, DRAWING NAME T.O. FINISHED FLOOR $I EXTERIOR 0 '-0" ELEVATIONS 7 TMP 4 TMP 3 2 3 2 3 4 7 TYP. TYP. DRAWING NO. EXTERIOR ELEVATION A201 3 8 M Q O Q Lo O co w tE O ol 7 I PLATFORM AND RAILINGS PLAN SCALE: 1/8"=l' -O" rr,rx 1 T I'Hh( I T V/-XK I T PARTY ' STORAGE WOMEN'S MEN'S FAMILY ROOM ROOM ROOM PREP KITCHEN 108 RESTROOM RESTROOM RESTROOM 112 111 110 109 107 106 105 c� t N T - KEYED NOTES: EXTENT OF RAILING TO BE FROM PLATFORM EDGE TO LOCATION SHOWN. COORDINATE OWITH TRAMPOLINE ENGINEER FOR TERMINATION LOCATIONS AND REQUIREMENTS. i EXTERIOR / EXPOSED EDGE TO RECEIVE CORER GUARD; JOHNSONITE '\/BG -XX -A-96'. (4' OR 8' PIECES CORNER GUARD, 1-1/2" RETURNS, 1/8" THICK. TAPERED ENDS) COLOR 40: BLACK. REFER TO SECTION 7/A203. O SINGLE LINE REPRESENTS PLATFORM EDGE WITH NO RAILING. (REFER TO TRAMPOLINE CONFIGURATION PLAN.) 1.8 OPLATFORM IS 35.6875" A.F.F. 2 O4 PLATFORM IS 61.6875" A.F.F. 5 RUBBER CORNER GUARD AT WALLS (VERTICAL), JOHNSONITE VBG -XX -B48, COLOR: BLACK (40) OPLATFORM SIDE WALL TO BE FINISHED IN PAINTED TYPE C GWB, REFER TO FINISH PLAN 2.4 ACCESS PANEL UNDER PLATFORM, REFER TO DETAIL 9/A2.2. COORDINATE FINAL OILOCATIONS W/ ARCHITECT AFTER ERECTIONS OF PLATFORM. O8 1-1/2" DA. GALVANIZED METAL GUARDED RAIL MOUNTED ON PLATFORM GRAPHIC LEGEND ELEVATED PLATFORM - 35.6875" A.F.F. QELEVATED PLATFORM - 61.6875" A.F.F. L.0 1 2'-0" HIGH ELEVATED PLATFORM ABOVE JUMPING MAT 3 %—(3.4 s Q N e z M O M 3.7 4 5 NOTES & LEGEND ARCHITECT 0 AM 0 design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www#waezwodesIgn.00m CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 Q O J LL �o Q = O W LL z ER Q O W T- oo t U W 0 O M M 1 REV I DATE I DESCRIPTION/ COMMENTS 1 SEAL ISSUED FOR: MIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: KH CHECKED BY: RK PROJECT NUMBER 2118015 Copyright (c) by Ph"ee Zero Design Corp. All Rights Reserved. DRAWING NAME PLATFORM AND RAILINGS PLAN DRAWING W. A301 GENERAL NOTES: 1. REFER TO STRUCTURAL ENGINEER'S PLANS FOR STRUCTURING OF PLATFORMS. 2. CONTRACTOR TO COORDINATE WITH TRAMPOLINE MANUFACTURER / INSTALLER FOR SEQUENCING OF PLATFORM CONSTRUCTION AND INSTALLATION OF TRAMPOLINE STRUCTURE. TRAMPOLINE INSTALLER REQUIRES TRAMPOLINE STRUCTURE TO BE INSTALLED FIRST, PRIOR TO PLATFORM INSTALLATION. 3. TRAMPOLINE STRUCTURE IS DESIGNED AND PERMITTED BY OTHERS. IF AVAILABLE FOR THIS DRAWING ISSUE, THE TRAMPOLINE DRAWINGS WILL BE INCLUDED FOR COORDINATION PURPOSES ONLY AND ARE NOT A PART OF THE DESIGN TEAM'S WORK. 4. THE TRAMPOLINE STRUCTURE AND THE PLATFORM STRUCTURE ARE FULLY SEPARATE STRUCTURES AND DO NOT PRODUCE ANY LATERAL OR LIVE LOADS ON EACH OTHER. F E D c B A.4 A.2 A 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEETING ALL REQUIRED CODES, 24'-11" 43'-11" SAFETY STANDARDS, ETC. IN THE DIMENSIONAL TOLERANCES WITH THE TRAMPOLINE TO 43'-11" 43'-11" 45'-0" '" 5-6 FLOOR REQUIRED ADHERENCES. DIMENSIONS SHOWN ON THIS PLAN ARE FOR DESIGN INTENT, PRICING, AND COORDINATION PURPOSES ONLY. i 6. ALL BUILDING CODE REQUIREMENTS FOR RAILINGS AND / OR GUARDRAILS SHALL BE 10'434" STRICTLY FOLLOWED BY THE CONTRACTOR AND RAILING / PLATFORM FABRICATOR. w. 1 RAILINGS SHALL MEET OR EXCEED MINIMUM STANDARDS FOR HORIZONTAL LOADS, DIMENSIONAL REQUIREMENTS, ETC. ALL RAILINGS SHALL BE SMOOTH AND FREE OF — — SHARP EDGES, BURRS, ETC. 1 177 7. CONTRACTOR SHALL CONFIRM CLEARANCE ABOVE LOW PLATFORM FROM ALL LIGHT FIXTURES, DUCTWORK, AND ANYTHING ABOVE HEAD TO BE AT A MINIMUM OF 17'-0" c� I ABOVE SLAB WITH ELEVATED PLATFORM, " WITH SLAB DEPRESSION 14'- CLEARANCE NCE Z 4 �.5' - ABOVE SLAB IS REQUIRED.MINIMUM CLEARANCE TO MEET ASTM 2970 1 21 20'-3" 14+-4h' 8. CONTRACTOR H C ORS SHALL CONFIRM CLEARANCE ABOVE HIGH PLATFORM F FROM ALL LIGHT " FIXTURES, D " U DUCTWORK AND ANYTHING ABOVE HEAD T OBE AT A MINIMUM OF 23 -0 s r 1-10Y2" N N "N "� r " ABOVE SLAB WITH ELEVATED PLATFORM, WITH SLAB DEPRESSION 18 -2 CLEARANCE 21_0" \ \ ABOVE SLAB IS REQUIRED. MINIMUM CLEARANCE TO MEET ASTM 2970. co N N N O I 16'-1�2" N N N 9. ALL RAILING START AND STOP POINTS MEETING TRAMPOLINE / COURTS SHALL BE I 6'-3" Z 4 1 T- COORDINATED WITH THE TRAMPOLINE ENGINEERS FOR APPROPRIATE ADJACENCY FOR T CODE REQUIREMENTS INCLUDING BUT NOT LIMITED TO NO GAP GREATER THAN 4". 4 5'-0" (, 3'-9" 8'-3" 3'-9" 8'-0" 8'-3" " 46'-94" N' TRAMPOLINE ENGINEER TO COORDINATE ALL PADDLING REQUIREMENTS. s " 10. REFER TO DETAILS BELOW FOR ADDITIONAL STAIR AND RAILING INFORMATION. A302 M .-t 4' . . ., ., _N -- — — 11. RUBBER NOSE GUARDS WITH CARPET RISERS AND TREADS AT ALL STAIRS. ch iN` V 7 I PLATFORM AND RAILINGS PLAN SCALE: 1/8"=l' -O" rr,rx 1 T I'Hh( I T V/-XK I T PARTY ' STORAGE WOMEN'S MEN'S FAMILY ROOM ROOM ROOM PREP KITCHEN 108 RESTROOM RESTROOM RESTROOM 112 111 110 109 107 106 105 c� t N T - KEYED NOTES: EXTENT OF RAILING TO BE FROM PLATFORM EDGE TO LOCATION SHOWN. COORDINATE OWITH TRAMPOLINE ENGINEER FOR TERMINATION LOCATIONS AND REQUIREMENTS. i EXTERIOR / EXPOSED EDGE TO RECEIVE CORER GUARD; JOHNSONITE '\/BG -XX -A-96'. (4' OR 8' PIECES CORNER GUARD, 1-1/2" RETURNS, 1/8" THICK. TAPERED ENDS) COLOR 40: BLACK. REFER TO SECTION 7/A203. O SINGLE LINE REPRESENTS PLATFORM EDGE WITH NO RAILING. (REFER TO TRAMPOLINE CONFIGURATION PLAN.) 1.8 OPLATFORM IS 35.6875" A.F.F. 2 O4 PLATFORM IS 61.6875" A.F.F. 5 RUBBER CORNER GUARD AT WALLS (VERTICAL), JOHNSONITE VBG -XX -B48, COLOR: BLACK (40) OPLATFORM SIDE WALL TO BE FINISHED IN PAINTED TYPE C GWB, REFER TO FINISH PLAN 2.4 ACCESS PANEL UNDER PLATFORM, REFER TO DETAIL 9/A2.2. COORDINATE FINAL OILOCATIONS W/ ARCHITECT AFTER ERECTIONS OF PLATFORM. O8 1-1/2" DA. GALVANIZED METAL GUARDED RAIL MOUNTED ON PLATFORM GRAPHIC LEGEND ELEVATED PLATFORM - 35.6875" A.F.F. QELEVATED PLATFORM - 61.6875" A.F.F. L.0 1 2'-0" HIGH ELEVATED PLATFORM ABOVE JUMPING MAT 3 %—(3.4 s Q N e z M O M 3.7 4 5 NOTES & LEGEND ARCHITECT 0 AM 0 design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www#waezwodesIgn.00m CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 Q O J LL �o Q = O W LL z ER Q O W T- oo t U W 0 O M M 1 REV I DATE I DESCRIPTION/ COMMENTS 1 SEAL ISSUED FOR: MIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: KH CHECKED BY: RK PROJECT NUMBER 2118015 Copyright (c) by Ph"ee Zero Design Corp. All Rights Reserved. DRAWING NAME PLATFORM AND RAILINGS PLAN DRAWING W. A301 ARCHITECT GENERAL NOTES: 1. ALL HAND RAILS TO BE A MINIMUM OF 34"A.F.F. AND MAXIMUM OF 38"A.F.F. 00 design 2. ALL GUARD RAILS TO BE 42" A.F.F. 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 3. HANDRAILS TO BE CONTINUOUS, TYP. PHONE: (781)452-7121 FAX: (781) 875-3039 4. HANDRAILS TO EXTEND 12" BEYOND BOTTOM TREAD/RISER, TYP. www.phasezmdesign.com RECESSED METAL PULL HARDWARE, CLIENT FINISH: BRUSHED NICHEL / STAINLESS STEEL 1-1/2" GALVANIZED METAL 4" MIN. 5. RUBBER NOSE GUARDS WITH CARPET RISERS AND TREADS AT ALL STAIRS. JUMP 2018 LLC RUBBER CORNER GUARD TUBE POST 10108 EVERGREEN LANE DRIVE STAINLESS STEEL PIANO HINGE 1-1/2" GALVANIZED METAL PHTAMPA, F 33647 ONE: (813)) 838-8896 TUBE BOTTOM RAIL MTL STUD BEYOND T.O. PLATFORM /� 4 x 4 x 3/8" BASE PLATE KEYED NOTES: 4" MIN. ELECTRICAL ENGINEER Z-11 5/8" W/ 4 LAG SCREWS EXTENT OF RAILING TO BE FROM PLATFORM EDGE TO LOCATION SHOWN. O1"NON-COMBUSTIBLE COORDINATE WITH TRAMPOLINE ENGINEER FOR TERMINATION LOCATIONS AND DECKING REQUIREMENTS. SINGLE LINE REPRESENTS PLATFORM EDGE WITH NO RAILING. (REFER TO BLACK RUBBER CORNER GUARD �O Z TRAMPOLINE CONFIGURATION PLAN.) 1-1/2" X 1-112" �' o \ JOHNSONITE 'VBG -XX -A-96' ' I 3 14 GA. ANGLE PLATFORM IS 35.6875" A.F.F. \ I ( \ \ 2X BLOCKING �4 \ 0 4 5 0 5 4O PLATFORM IS 61.6875" A.F.F. \ in ch PLATFORM M DON PENN CONSULTING ENGINEER I\ @ 35.6875" A.F.F 1301 SOLANA BLVD. O1-1/2" DIA. GALVANIZED METAL HANDRAIL, SMOOTH FINISH BLDG. 1 I SUITE 1420 I5/8" TYPE 'C' GWB PAINTED, 6 6 \ O ESTLAK , T I F 817.251.8411 CI / REFER TO FINISH PLAN PLATFORM FLORIDA ENGINEER NO. 0051096 (MECH) @ 61.6875" A.F.F 12 6 i 1-1/2" DIA., GALVANIZED METAL TOP RAILING & POST, TYPICAL, SMOOTH FINISH j @ 9 8 MECHANICAL 8 PLUMBING ENGINEER I I / PLATFORM JOISTS & STUDS, REFER TO STRUCT. DRAWINGS O PAINTED STEEL STRINGERS STAIR EDGES & CENTER OF WIDTH. Lu IDSTUDIoa I v- � 11 r _ 11 I 1431 GREENWAY DRIVE NlIx IRVING, TX 75038 '7 a_i W O STAIR TREADS: PLYWOOD COVERED IN CARPET CT -02, BLACK RUBBER NOSING PHONE: (972) 870-1288 N j2 9 8 m Lu 7 PLATFORM STRUCTURAL ENGINEER @ 35.6875" A.F.F. OZABIK STAIR RISERS: PLYWOOD COVERED IN CARPET CT -02 TURNER ENGINEERING JENNIFER ZABIK, PE, SE 2'-6- WIDE, 3/4" PLYWOOD PAINT GRADE ACCESS DOOR,1'-O" 4'_7" 1'-O" 1024 N FULLERS CROSS ROAD PAINTED, REFER TO FINISH PLAN FOR COLOR 21-9" 5 EQ. TREADS @ 11" EA. 10 SECURE STEEL STRINGERS TO CONCRETE FLOOR. WINTER GARDEN, FL 34787 DOOR STOP / JAMB ON INTERIOR WALL BASE AS SCHEDULED 3 EQ. TREADS @ 11" EA. PHONE: (407) 864-8120 5/8" GWB PAINTED, ii 1-1/2" DIA., GALVANIZED METAL BOTTOM RAIL, SMOOTH FINISH REFER TO FINISH PLAN FOR COLOR WALL BASE B-01 12" DIA., METAL BALLUSTERS 4" O.C. MAX; GALVANIZED METAL, SMOOTH FINISH DETAIL @ PLATFORM ACCESS PANEL GUARDRAIL MOUNTING DETAIL ELEVATION/SECTION @ STAIR ELEVATION/13SECTION @ STAIR RAMP AND STAIR FLOORING -CT -02 8 1-1/2"=1'-0" 7 3!4"=1'-0" 6 3/4"=1'-0" <8> 4 RUBBER CORNER GUARDS; 3/4"X 3/4" AT WALLS (VERTICAL) AND 1-1/2"X 1-1/2" AT EDGE OF PLATFORM (HORIZONTAL). GRAPHIC LEGEND F-7 I ELEVATED PLATFORM - 35.6875" A.F.F. ELEVATED PLATFORM - 61.6875" A.F.F. 2'-0" HIGH ELEVATED PLATFORM ABOVE JUMPING MAT 8 19-0" 3 E.Q. TREADS A302 s @ 11- EACH O O NOTES & LEGEND s s 6 O 13J 7Z5 3 5 13 1 0 LL 5 =7 Q U A302 6 A302 14 5 5 5 = W s A 02 A302 m U 7 13 CIUJI 0 Q xl 10 o 5 w d d11IN "Z1111w `ID Cl ui O 4 3 s A30U P A302 U P 2 U P 4 7 10 7 10 7 10 6 \` 8'-11" CLEAR 6'-1034" 6'-1034" 10'-0" 15'-0" 4 ce) 6 ENLARGED PLAN @ STAIRS TO UPPER PLATFORM 5 ENLARGED PLAN @ STAIRS ENTRANCE 4 ENLARGED PLAN @ STAIRS ENTRANCE 1 /2"=1'-0" 1 /2"=1'-0" 1 /2"=1'-0" eQ 6Wu— = O 41'-0" 5 z z 59-0" Q � 5'-0" 0 41 10 W o SEAL . ENLARGED PLAN @ STAIRS ENTRANCE, 3 O 6 A302 7 10 4'-21/2" CLEAR 5'-0" 1-0 3 E.Q. TREADS " 6Wu— = O 41'-0" z z 59-0" Q � 5'-0" 0 41 10 W o SEAL . ENLARGED PLAN @ STAIRS ENTRANCE, 3 O a 1-0 3 E.Q. TREADS " U W 0 a REVISIONS REV DATE DESCRIPTION COMMENTS I A302 I 5 5 Q U P UP 41'-0" 59-0" 18'-0" 5'-0" 18'-0" 5'-0" 41 10 SEAL . ENLARGED PLAN @ STAIRS ENTRANCE, 3 6 s 1-0 3 E.Q. TREADS " @ 11" EACH 6 O I A302 I 5 5 Q U P UP w ISSUED FOR: PERMIT - BID � J O LO O 13 13 13 I 7 A30 ISSUED DATE: 04.04.2018 DRAWN BY: KLH I T ' 6 5 5 J CHECKED BY: RK U 7 iO NUMBER: 2118015 rPROJECT 13 L---------- �. 10 '\ Copyright (c) by Phase Zero Design Corp. All Rights Reserved. DRAWING NAME j i 8 5 1'-0" 1'_oa A3o2 PLATFORM 14 STAIR AND RAMP DETAILS DRAWING NO. A302 2 ENLARGED PLAN @RAMP ENTRANCE -PLATFORM,� ENLARGED PLAN @STAIRS TO UPPER PLATFORM 1/2"=1'-0" E 141 PLATFORM ELEVATION 3/8"=1'-0" O 10'-0" 1V-33/4" 1 _ 10'-42" I. 14 6 i ,—< 12 5 14'-10" GENERAL NOTES: 1. ALL HAND RAILS TO BE A MINIMUM OF 34" A.F.F. AND MAXIMUM OF 38" A.F.F. 2. ALL GUARD RAILS TO BE 42" A.F.F. 3. HANDRAILS TO BE CONTINUOUS, TYP. 4. HANDRAILS TO EXTEND 12" BEYOND BOTTOM TREAD/RISER, TYP. 5. RUBBER NOSE GUARDS WITH CARPET RISERS AND TREADS AT ALL STAIRS. KEYED NOTES: OF RAILING TO BE FROM PLATFORM EDGE TO LOCATION SHOWN. OEXTENT COORDINATE WITH TRAMPOLINE ENGINEER FOR TERMINATION LOCATIONS AND 21-9" REQUIREMENTS. LINE REPRESENTS PLATFORM EDGE WITH NO RAILING. (REFER TO OSINGLE TRAMPOLINE CONFIGURATION PLAN.) OPLATFORM IS 35.6875" A.F.F. OPLATFORM IS 61.6875" A.F.F. O1-1/2" DIA. GALVANIZED METAL HANDRAIL, SMOOTH FINISH O1-1/2" DIA., GALVANIZED METAL TOP RAILING & POST, TYPICAL, SMOOTH FINISH O7 PAINTED STEEL STRINGERS STAIR EDGES & CENTER OF WIDTH. OS STAIR TREADS: PLYWOOD COVERED IN CARPET CT -02, BLACK RUBBER NOSING OSTAIR RISERS: PLYWOOD COVERED IN CARPET CT -02 0 <8> SECURE STEEL STRINGERS TO CONCRETE FLOOR. 1 <8> 1-1/2" DIA., GALVANIZED METAL BOTTOM RAIL, SMOOTH FINISH 12 j" DIA., METAL BALLUSTERS 4" O.C. MAX; GALVANIZED METAL, SMOOTH FINISH 13 RAMP AND STAIR FLOORING - CT -02 4 RUBBER CORNER GUARDS; 3/4"X 3/4" AT WALLS (VERTICAL) AND 1-1/2"X 1-1/2" AT 8> EDGE OF PLATFORM (HORIZONTAL). 5 <8> EXISTING STEEL COLUMN TO BE PAINTED PT -02. 16 ACCESS PANEL UNDER PLATFORM. REFER TO DETAIL 9/A3.2. COORDINATE FINAL LOCATION WITH ARCHITECT AFTER ERECTION OF THE PLATFORM. 131 PLATFORM ELEVATIONI ( NOTES I 3/8"=1'-0" O 14 121 PLATFORM ELEVATION - RAMP 3/8"=1'-0" m c� G 6 i r--<1 2> f--< 1 1 r--< 5 441-2" N 151-011 �14 g PT -05 5 8-01 TYP 20'-158" 21-9" i IPLATFORM ELEVATION 3/8"=1'-0" 5 18'-0" 1'-0" PT -05 14 \ \/ PT -05 C B-01 TYP. B-01 TYP. ll' -2y2- 6 21 -9w 5'-0" 41'-0" 0 B-01 SLOPE 11.12 18'-O" PT -04 30'-5%8" i[l _ En O ARCHITECT 04, design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.owez odesign.=n CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUDIO4 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 L) U W O tY CL 0 Q O� LL F— �o = O LLJ Z_ Z E Q O U) T— oo It— REVISIONS REn DATE I DESCRIPTION / COMMENTS ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: KLH CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. All Rights Reserved. DRAWING NAME PLATFORM ELEVATIONS DRAWING NO A303 GENERAL NOTES: 1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS. IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE CONSTRUCTION MANAGER. 2. VERIFY SIZE, LOCATION, AND CHARACTERISTICS, OF ALL WORK AND EQUIPMENT TO BE FURNISHED BY OWNER OF OTHERS, WITH THE MANUFACTURER OR SUPPLIER BEFORE ANY CONSTRUCTION PERTAINING TO SAME IS BEGUN. 3. ALL DIMENSIONS ON PLANS ARE TO FACE OF FRAMING UNLESS OTHERWISE NOTED. 4. FIRE EXTINGUISHER: 10 CLASS ABC WITH UL RATING 4A-60BC. SURFACE MOUNTED ON WALL WITH MANUFACTURERS ALL STEEL WALL BRACKET. JL INDUSTRIES INC. (COSMIC 10E) OR APPROVED EQUAL WITH INSPECTION TAG AS REQUIRED BY LOCAL CODES. 5. ALL WORK SHALL BE IN COMPLIANCE FEDERAL, STATE AND LOCAL BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS. 6. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. 7. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. 8. THE G.C. SHALL ACQUAINT HIMSELF WITH THE BARRIER FREE REQUIREMENTS FOR THE STATE OF OH AND THE AMERICAN DISABILITIES ACT (ADA) AND SHALL INSURE THAT THIS SPACE WILL BE ACCESSIBLE ACCORDING TO THE STRICTER REQUIREMENTS OF THE APPLICABLE STANDARDS. 9. PATCH AND REPAIR ALL WALLS AND FLOORS AS NEEDED TO RECEIVE NEW FINISHES. NOTES SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24"1— TILE 2"X24";TILE W-01 W J N J C� M SCHLUTER- SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24", TILE W-01 i F9 F9 SII 19 MEN'S RESTROOM ELEVATION18 I MEN'S RESTROOM ELEVATION SCALE: 1/2"=1'-0" 1 SCALE: 1/2"=1'-0" J U 0 'cM 171 MEN'S RESTROOM ELEVATION SCALE: 1/2"=1'-0" FULL HEIGHT 12"X24" TILE W-01 SYSTEMS pT-01 SCHIENE ALUMINUM TRIM EDGE, TYP. G G 5 ROWS, 12"X24", TILE W-01 C FULL HEIGHT 12"X24" TILE W-01 15 ( WOMEN'S RESTROOM ELEVATION SCALE: 1/2"=V-0" SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24 TILE W-01 C J LO SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24", TILE W-01 3 WOMEN'S RESTROOM ELEVATION SCALE: 1/2"=1'-0" u 3r -4e D2 3'-6" _ 1'-0„ D 1 A J U Q � M 7"-9" CL W FLOOR MOUNTED TOILET H LAVATORY - 21"X 18" LUCERNE WALL MOUNTED VITREOUS CHINA SINK WITH INTEGRAL BACKSPLASH BY AMERICAN STANDARD, MODEL. NO. 0356.028. COLOR. FRAME WHITE. PROVIDE SUPPLIES WITH STOP VALVES, P -TRAP, TAILPIECE AND H ESCUTCHEONS (ALL CHROMED) AND SYMMONS SYMMETRIX' SINGLE LEVER OTOILET PAPER DISPENSER - CLASSIC SERIES SURFACE MTD. MULTI ROLL DISPENSER et CHROME FAUCET MODEL S -20 -2 -G -FR -W WITH GRID STRAINER. PROVIDE J.R. SMITH FIG. 700 MATCHING FLOOR MOUNTED FIXTURE 19 MEN'S RESTROOM ELEVATION18 I MEN'S RESTROOM ELEVATION SCALE: 1/2"=1'-0" 1 SCALE: 1/2"=1'-0" J U 0 'cM 171 MEN'S RESTROOM ELEVATION SCALE: 1/2"=1'-0" FULL HEIGHT 12"X24" TILE W-01 SYSTEMS pT-01 SCHIENE ALUMINUM TRIM EDGE, TYP. G G 5 ROWS, 12"X24", TILE W-01 C FULL HEIGHT 12"X24" TILE W-01 15 ( WOMEN'S RESTROOM ELEVATION SCALE: 1/2"=V-0" SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24 TILE W-01 C J LO SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24", TILE W-01 3 WOMEN'S RESTROOM ELEVATION SCALE: 1/2"=1'-0" u 3r -4e D2 3'-6" _ 1'-0„ D 1 A J U Q � M 7"-9" CL 61 MEN'S RESTROOM ELEVATION SCALE: 1/2"=l' -O" 3'-4" SCHLUTER SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24', TILE W-01 SCHLUTER SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24" JD3 TILE w-01 D2 01 B D 1 1'-0" L. T-6" lk A w -o1 W U) U � � a r 4 WOMEN'S RESTROOM ELEVATION SCALE: 1/2"=l' -O' SCHLUTER DOOR PT -02 SYSTEMS FRAME SCHIENE ALUMINUM TRIM EDGE, / TYP. / 5 ROWS, 12"X24", / TILE W-01 / / / G I o \ J I T \ ' N \ 2 WOMEN'S RESTROOM ELEVATION SCALE: 1/2"=V-0" RESTROOM ACCESSORIES PDOOR T-02 FLOOR MOUNTED TOILET H LAVATORY - 21"X 18" LUCERNE WALL MOUNTED VITREOUS CHINA SINK WITH INTEGRAL BACKSPLASH BY AMERICAN STANDARD, MODEL. NO. 0356.028. COLOR. FRAME WHITE. PROVIDE SUPPLIES WITH STOP VALVES, P -TRAP, TAILPIECE AND G ESCUTCHEONS (ALL CHROMED) AND SYMMONS SYMMETRIX' SINGLE LEVER OTOILET PAPER DISPENSER - CLASSIC SERIES SURFACE MTD. MULTI ROLL DISPENSER CHROME FAUCET MODEL S -20 -2 -G -FR -W WITH GRID STRAINER. PROVIDE J.R. SMITH FIG. 700 MATCHING FLOOR MOUNTED FIXTURE BOBRICK, MODEL. B-2888, SATIN FINISH. MTD. MIN.24" A.F.F. TO CENTERLINE OF ROLL. SUPPORT. INSULATE EXPOSED I \ WATER AND WASTE WITH TRUEBRO HANDI LAV -GUARD INSULATION KIT MODEL #102W OFFSET TRAP AND DRAIN, MAINTAIN UNOBSTRUCTED KNEE CLEARANCES. OTOILET PARTITIONS -BRADLEY, FLOOR MOUNTED WITH OVERHEAD BRACE. POWDER COATED, COLOR: WARM GRAY. STAINLESS STEEL CONCEALED, SIDE LATCH AND O HAND DRYER - BOBRICK B-7128; QUICK DRY TRIM DRY SURFACE MOUNTED ADA DRYER; KEEPER. STAINLESS STEEL STIRRUP BRACKETS STAINLESS STEEL COVER D1 8 36" LONG GRAB BAR -1 41" 0 STAINLESS STEEL TUBING, PEENED FINISH BY BOBRICK, OK COAT HOOK - BOBRICK #B-6717, MTD. @ 4'-0" A.F.F. TO TOP MODELB-5806.99 X 36, SATIN FINISH. MTD. 33" - 36" A.F.F. D2 42" LONG GRAB BAR - 1 41" 0 STAINLESS STEEL TUBING, PEENED FINISH BY BOBRICK, O ELECTRIC WATER COOLER HI/LO, REFER TO PLUMBING DRAWINGS MODEL B-5806.99 X 42, SATIN FINISH. MTD. 33"- 36" A.F.F. H i \ D3 18"LONG GRAB BAR -VERTICAL -MTD. @ 2'-9 1/2" A.F.F. (V.I.F.) TO TOP O BABY CHANGING STATION: KOALA -CARE MODEL #KBZOO, COLOR: WHITE GRANITE MF MFG. BY BOBRICK #B-5806.99 X 36 OE WALL MOUNTED URINAL NOTES: DISPENSER - HEAVY-DUTY SURFACE MTD.STAINLESS STEEL DISEPNSER BY / OSOAP F e 1. PROVIDE FIRE RETARDANT TREATED (F.R.T.) WOOD BLOCKING IN WALLS AS REQUIRED / FOR INSTALLATION OF TOILET ROOM ACCESSORIES AND FIXTURES. OFIXED MIRROR - 24"W X 36"H STAINLESS STEEL CHANNEL -FRAME MIRROR BY N BOBRICK, MODEL.B-165-2436. BOTTOM EDGE OF REFLECTING SURFACE MTD. MAX. (V .. / i i 61 MEN'S RESTROOM ELEVATION SCALE: 1/2"=l' -O" 3'-4" SCHLUTER SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24', TILE W-01 SCHLUTER SYSTEMS SCHIENE ALUMINUM TRIM EDGE, TYP. 5 ROWS, 12"X24" JD3 TILE w-01 D2 01 B D 1 1'-0" L. T-6" lk A w -o1 W U) U � � a r 4 WOMEN'S RESTROOM ELEVATION SCALE: 1/2"=l' -O' SCHLUTER DOOR PT -02 SYSTEMS FRAME SCHIENE ALUMINUM TRIM EDGE, / TYP. / 5 ROWS, 12"X24", / TILE W-01 / / / G I o \ J I T \ ' N \ 2 WOMEN'S RESTROOM ELEVATION SCALE: 1/2"=V-0" RESTROOM ACCESSORIES FLOOR MOUNTED TOILET H LAVATORY - 21"X 18" LUCERNE WALL MOUNTED VITREOUS CHINA SINK WITH INTEGRAL BACKSPLASH BY AMERICAN STANDARD, MODEL. NO. 0356.028. COLOR. WHITE. PROVIDE SUPPLIES WITH STOP VALVES, P -TRAP, TAILPIECE AND ESCUTCHEONS (ALL CHROMED) AND SYMMONS SYMMETRIX' SINGLE LEVER OTOILET PAPER DISPENSER - CLASSIC SERIES SURFACE MTD. MULTI ROLL DISPENSER CHROME FAUCET MODEL S -20 -2 -G -FR -W WITH GRID STRAINER. PROVIDE J.R. SMITH FIG. 700 MATCHING FLOOR MOUNTED FIXTURE BOBRICK, MODEL. B-2888, SATIN FINISH. MTD. MIN.24" A.F.F. TO CENTERLINE OF ROLL. SUPPORT. INSULATE EXPOSED WATER AND WASTE WITH TRUEBRO HANDI LAV -GUARD INSULATION KIT MODEL #102W OFFSET TRAP AND DRAIN, MAINTAIN UNOBSTRUCTED KNEE CLEARANCES. OTOILET PARTITIONS -BRADLEY, FLOOR MOUNTED WITH OVERHEAD BRACE. POWDER COATED, COLOR: WARM GRAY. STAINLESS STEEL CONCEALED, SIDE LATCH AND O HAND DRYER - BOBRICK B-7128; QUICK DRY TRIM DRY SURFACE MOUNTED ADA DRYER; KEEPER. STAINLESS STEEL STIRRUP BRACKETS STAINLESS STEEL COVER D1 8 36" LONG GRAB BAR -1 41" 0 STAINLESS STEEL TUBING, PEENED FINISH BY BOBRICK, OK COAT HOOK - BOBRICK #B-6717, MTD. @ 4'-0" A.F.F. TO TOP MODELB-5806.99 X 36, SATIN FINISH. MTD. 33" - 36" A.F.F. D2 42" LONG GRAB BAR - 1 41" 0 STAINLESS STEEL TUBING, PEENED FINISH BY BOBRICK, O ELECTRIC WATER COOLER HI/LO, REFER TO PLUMBING DRAWINGS MODEL B-5806.99 X 42, SATIN FINISH. MTD. 33"- 36" A.F.F. D3 18"LONG GRAB BAR -VERTICAL -MTD. @ 2'-9 1/2" A.F.F. (V.I.F.) TO TOP O BABY CHANGING STATION: KOALA -CARE MODEL #KBZOO, COLOR: WHITE GRANITE MF MFG. BY BOBRICK #B-5806.99 X 36 OE WALL MOUNTED URINAL NOTES: DISPENSER - HEAVY-DUTY SURFACE MTD.STAINLESS STEEL DISEPNSER BY OSOAP F BOBRICK, MODEL 818615 CONTURA SERIES, SATIN FINISH. 1. PROVIDE FIRE RETARDANT TREATED (F.R.T.) WOOD BLOCKING IN WALLS AS REQUIRED FOR INSTALLATION OF TOILET ROOM ACCESSORIES AND FIXTURES. OFIXED MIRROR - 24"W X 36"H STAINLESS STEEL CHANNEL -FRAME MIRROR BY BOBRICK, MODEL.B-165-2436. BOTTOM EDGE OF REFLECTING SURFACE MTD. MAX. 40" A.F.F. N C7: RESTROOM ACCESSORIES SCHEDULE 7 ENLARGED PLAN: MULTI STALL RESTROOMS ARCHITECT design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.�.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUDI04 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 SEAL ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: AJ CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phew Zero Deslgn Corp. AH RW to Reserved. DRAWING NAME RESTROOM DETAILS - MULTI STALL DRAWING NO. A401 O 3 CV O 4 O Q LO CD r c m E 3 0 a FULL HEIGHT - 12"X24" TILE W-01 15 I FAMILY RESTROOM ELEVATION I SCALE: 1/2"=V-0" SYSTEMS (FRAME pT-02 SCHIENE ONLY) ALUMINUM TRIM EDGE, TYP. / 5 ROWS, / 12"X24", / TILE W-01 / K / / W GENERAL NOTES: 1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS. IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE CONSTRUCTION MANAGER. a 2. VERIFY SIZE, LOCATION, AND CHARACTERISTICS, OF ALL WORK AND EQUIPMENT TO BE FURNISHED BY OWNER OF J OTHERS, WITH THE MANUFACTURER OR SUPPLIER BEFORE ANY CONSTRUCTION PERTAINING TO SAME IS BEGUN. 3. ALL DIMENSIONS ON PLANS ARE TO FACE OF FRAMING UNLESS OTHERWISE NOTED. w 4. FIRE EXTINGUISHER: 10 CLASS ABC WITH UL RATING 4A-60BC. SURFACE MOUNTED ON WALL WITH MANUFACTURERS ALL STEEL WALL BRACKET. JL INDUSTRIES INC. (COSMIC 10E) OR APPROVED EQUAL WITH to INSPECTION TAG AS REQUIRED BY LOCAL CODES. 5. ALL WORK SHALL BE IN COMPLIANCE FEDERAL, STATE AND LOCAL BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS. O� 6. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND J LL FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. le-esso 7. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND ANY SHUT DOWN OF � LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND o LOCAL BUILDING DEPARTMENT. W 8. THE G.C. SHALL ACQUAINT HIMSELF WITH THE BARRIER FREE REQUIREMENTS FOR THE STATE OF OH AND THE U AMERICAN DISABILITIES ACT (ADA) AND SHALL INSURE THAT THIS SPACE WILL BE ACCESSIBLE ACCORDING TO o THE STRICTER REQUIREMENTS OF THE APPLICABLE STANDARDS. M 9. PATCH AND REPAIR ALL WALLS AND FLOORS AS NEEDED TO RECEIVE NEW FINISHES. W o NOTES 15 I FAMILY RESTROOM ELEVATION I SCALE: 1/2"=V-0" SYSTEMS (FRAME pT-02 SCHIENE ONLY) ALUMINUM TRIM EDGE, TYP. / 5 ROWS, / 12"X24", / TILE W-01 / K / / W OC a J a w \ to O O� J LL (L le-esso � o 01 f:] G Z 04 FOUNTAIN TLE FILLING N. REFER TO ING DRAWINGS RESTROOM ACCESSORIES OFLOOR MOUNTED TOILET OTOILET PAPER DISPENSER - CLASSIC SERIES SURFACE MTD. MULTI ROLL DISPENSER BOBRICK, MODEL. B-2888, SATIN FINISH. MTD. MIN.24" A.F.F. TO CENTERLINE OF ROLL. OTOILET PARTITIONS - BRADLEY, FLOOR MOUNTED WITH OVERHEAD BRACE. POWDER COATED, COLOR: WARM GRAY. STAINLESS STEEL CONCEALED, SIDE LATCH AND KEEPER. STAINLESS STEEL STIRRUP BRACKETS D1 36" LONG GRAB BAR -1 41" 0 STAINLESS STEEL TUBING, PEENED FINISH BY BOBRICK, MODELB-5806.99 X 36, SATIN FINISH. MTD. 33" - 36" A.F.F. D2 42" LONG GRAB BAR -1 41" 0 STAINLESS STEEL TUBING, PEENED FINISH BY BOBRICK, MODEL B-5806.99 X 42, SATIN FINISH. MTD. 33" - 36" A.F.F. D3 18" LONG GRAB BAR - VERTICAL - MTD. @ 2'-9 1/2" A.F.F. (V.I.F.) TO TOP MFG. BY BOBRICK #B-5806.99 X 36 OWALL MOUNTED URINAL SOAP DISPENSER - HEAVY-DUTY SURFACE MTD.STAINLESS STEEL DISEPNSER BY BOBRICK, F MODEL 818615 CONTURA SERIES, SATIN FINISH. OFIXED MIRROR - 24" W X 36" H STAINLESS STEEL CHANNEL -FRAME MIRROR BY BOBRICK, MODEL.B-165-2436. BOTTOM EDGE OF REFLECTING SURFACE MTD. MAX. 40" A.F.F. OLAVATORY - 21"X 18" LUCERNE WALL MOUNTED VITREOUS CHINA SINK WITH INTEGRAL BACKSPLASH BY AMERICAN STANDARD, MODEL NO. 0356.028. COLOR. WHITE. PROVIDE SUPPLIES WITH STOP VALVES, P -TRAP, TAILPIECE AND ESCUTCHEONS (ALL CHROMED) AND SYMMONS SYMMETRIX' SINGLE LEVER CHROME FAUCET MODEL S -20 -2 -G -FR -W WITH GRID STRAINER. PROVIDE J.R. SMITH FIG. 700 MATCHING FLOOR MOUNTED FIXTURE SUPPORT. INSULATE EXPOSED WATER AND WASTE WITH TRUEBRO HANDI LAV -GUARD INSUALTION KIT MODEL #102W OFFSET TRAP AND DRAIN, MAINTAIN UNOBSTRUCTED KNEE CLEARANCES. OHAND DRYER - BOBRICK B-7128; QUICK DRY TRIM DRY SURFACE MOUNTED ADA DRYER; STAINLESS STEEL COVER OK COAT HOOK - BOBRICK #B-6717, MTD. @ 4'-0" A.F.F. TO TOP UL ELECTRIC WATER COOLER HI/LO, REFER TO PLUMBING DRAWINGS QBABY CHANGING STATION: KOALA -CARE MODEL #KBZOO, COLOR: WHITE GRANITE NOTES: 1. PROVIDE FIRE RETARDANT TREATED (F.R.T.) WOOD BLOCKING IN WALLS AS REQUIRED FOR INSTALLATION OF TOILET ROOM ACCESSORIES AND FIXTURES. 161 INTERIOR ELEVATION - WATER FOUNTAINI I SCHEDULES I SCALE: 3/4"=1'-0" 141 FAMILY RESTROOM ELEVATION I SCALE: 1/2"=1'-0" SCH SYS' SCH ALUI TRIM TYP. 5 RC 12"X TILE cn w to 13 1 FAMILY RESTROOM ELEVATION I SCALE: 1/2"=V-0" 21 FAMILY RESTROOM ELEVATION SCALE: 1/2"=1'-0" LUTER TEMS IENE MINUM A EDGE, )WS, 24", W-01 1 r ENLARGED PLAN: FAMILY RESTROOMS SCALE: 1/2"=l' -O" ARCHITECT 0 AML 0 design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezerodesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 Y OC a a w Z o O� J LL (L le-esso � o W LL z EE Q W o D H H J Q 1 REV I DATE I DESCRIPTION/ COMMENTS 1 SEAL ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: AJ CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. AN Rights Reserved. DRAWING NAME RESTROOM DETAILS - FAMILY DRAWING NO. A402 MATCH PLAN 6 A501 /_l FOR- 1 TOP FOR- 2 04 INTERIOR MATERIAL & FINISHES FQR-1 WILSONART #1595-22, COLOR: TEXTURED BLACK FQR-Z WILSONART #7995-38, COLOR: STERLING ASH FQjt-$ WILSONART #1595-60, COLOR: BLACK FQR-4 WILSONART #L6442-408, COLOR: PALLADIUM, FINISH: SATIN BRUSHED ARCHITECT CID) design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezerodesignmom CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER / FAQ 1'-6" TYP. FOR- 2 DON PENN CONSULTING ENGINEER FILLER, TYP. t:::� FOR- 31301 SOLANA BLVD. 3'-0" FINISHED BLDG. 1 I SUITE 1420 END PANEL WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER NOTES: IDSTUD104 MILLWORK HARDWARE TO BE BAR STYLE PULLS. BRUSHED SATIN. 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 11 REAR CABINETS ELEVATION SCHEDULE STRUCTURAL ENGINEER SCALE: 1/2"=1'-0" ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 MATCH PLAN 3 4 2 MATCH PLAN A501 A501 A501 Zop 1 41 24 5 3 A501A501 A501 A501 — — — G.C. TO COORDINATE 2'-10" HIGH COUNTER 1 \ tGROMMET LOCATIONS WITH WITH CABINETS BELOW P I I \ OPEN / OWNER PRIOR TO FOR- 2 \ / INSTALLATION. GROMMETS TO FA E / \ BE 2" STAINLESS STEEL. 7 / \ A 7 2'-10" HIGH COUNTER / 3 4 2 (MAX) OPEN BELOW Ii v OPEN/ / I; V I I / I I \ A501 A501 A501 � 11.3,1 �.P 13'-8y2" N X FOR- 2 / \ FOR- 3 \4I-KFOR- 3 TILER, TYP. o WAIVER B3 W FINISHED END PANEL, FOR- 3 7r FOR-4FILLER, TYP--J 01 - - - I J J 0 II� � I� a. � o 51.011 Q I( 1 11R.— � 7 0 WAIVER & FRONT DESK ELEVATION 9 WAIVER & FRONT DESK ELEVATION = O I I 9 '-8 W 0 SCALE: 1/2"=l' -O" SCALE: 1/2"=l' -O" 2'-10" HIGH COUNTER I / \ Z Q WITH SHELVES BELOW I I 3 II r A501 #8 TRUSS HEAD, I I { I Q 00 STAINLESS STEEL, I I I MATCH PLAN EQUALLY SPACED TYP. I I MATCH PLAN 0 3 5 4 2 2 4 3 I / A501 A501 A501 A501 A501 A501 A501 WITH HIGH COUNTER I ( \ \ WITH CABINETS BELOW / N FOR- 1 #8 TRUSS HEAD, STAINLES FOR- 1 5 I I TOP %STEEL, EQUALLY SPACED TYP. A501 TV (WALL HUNG) @ 6'-0" AFF ° ° ° ° ° ° ° ° ° ° TOP I Iku 9 11 I I A501 A501 , ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° sO I -- o N FACE FOR- 4 ° r`? N II CV ° ' ° FACE ° ! A501 04 01 I I � 21_011 ° o ° ° ° ° ° o o ° ° ° ° o ° ° ° ° e ° ° ° ° ° ° ° ° ° ° ° e ° o ° ° o o ° ° o ° e ° o I I m ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° II N I 2'-10" HIGH COUNTER — — — (MAX) CABINETS BELOW 4 I 41 6 A501 I I A501 3 I IJr%a G.C. TO COORDINATE REVISIONS REV DATE DESCRIPTION COMMENTS GROMMET LOCATIONS WAIVER & FRONT DESK ELEVATION WAIVER & FRONT DESK ELEVATION WITH OWNER PRIOR TO 1 8 SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0" INSTALLATION. GROMMETS TO BE 2" STAINLESS W STEEL. Z 0 LL 2'-10" HIGH COUNTER (MAX 2'-0" OPEN BELOW SEAL to FOR- 1 FOR -1 1 11 21-0" FOR -1 2,_0" TOP TOP 2.0 2'-0" FOR -1 FOR -1 I I / APPLIANCES FURNISHED AND TOP/FACE BLOCKING %TOP 2 / INSTALLED BY TENANT, TYP. %TOP A2 2 ADJUSTABLE W ! ( ! SHELVES, FOR -3 BLOCKING ! BLOCKING 11.61 " — — — r- CO 1 FOR -3 M FOR -4 FOR -2 FOR -3 FACE FOR -4 14. FOR- 2 FOR -3 FOR -4 FOR- 2 FOR -3 FOR -4 2'-0" 11'-8/2" ISSUED FOR: PERMIT -BID N FACE N FACE jam: FACE N FACE �: FACE FACE ' N N FZ ISSUED DATE: 04.04.2018 j FIXED BASE 3'-6" 3 DRAWN BY: SV FOR - j FACE EllW CHECKED BY: RK W BLOCKING NJ BLOCKING BLOCKING BLOCKING 04 0 PROJECT NUMBER: 2118015 M! M ! M Copyright (c) by Phase Zero Design Corp. AO Rights Reserved. — — — —DRAWING NAME 1'-73/4" V-41/2. "42" Z INTERIOR DETAILS - 4'-0" 4'-73/4" FRONT DESK/ CONCESSIONS DRAWING NO. REAR SECTION - CABINET FRONT DESK SECTION - I F _ _ A501 6 5 S S O HIGH TOP 4 FRONT DESK SECTION CABINETS 3 FRONT DESK SECTION SHELVES 2 ADA COUNTER SECTION ,� ENLARGED WAIVER /FRONT DESK PLAN SCALE: 1 "=1'-0" SCALE: 1"=l' -O" SCALE: 1.=l -0.1 SCALE: 1"=l' -O" SCALE: 1"=l' -O" SCALE: 1/2"=l' -O" INTERIOR MATERIAL & FINISHES FOR -1 WILSONART #1595-22, COLOR: TEXTURED BLACK FQR-Z WILSONART #7995-38, COLOR: STERLING ASH 4 0 �4 CV II II I I I I 0 EE I 1 II II FQR-$ WILSONART #1595-60, COLOR: BLACK ARCHITECT At k ■ design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezerodesign.wn CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER NOTES: MILLWORK HARDWARE TO BE BAR STYLE PULLS. BRUSHED SATIN. DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 FOR- 3 2" CUSHION 2"CUSHION PROVIDED BY PROVIDED OTHERS BY OTHERS PER PLAN a FOR- 3 W _Z o ! cj�0. J = O ti 0- uj LL Z _o 6Y2" 1'-1Y2" 00 TYP. 3�4„ Q r TYP. FRONT ELEVATION SECTION J Q 3 BENCH/SHOE CUBBY DETAIL SCALE: 1 1/2"=l' -O" U w O a REVISIONS REV DATE DESCRIPTION / COMMENTS 2'-6" FOR -1 TOP/FACE i 2,_08„ 1" FOR- 2 O ACE F G.C. TO COORDINATE GROMMET 04 LOCATIONS WITH OWNER PRIOR TO INSTALLATION. GROMMETS FOR- 3 BLOCKING TO BE 2" STAINLESS STEEL. FACE i ! B-01 2'-10" HIGH COUNTER (MAX) OPEN BELOW I 478„ FINISHED E FOR -4 SEAL TV (WALL HUNG) @ 6'-0" AFF ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: AJ CHECKED BY: RK PROJECT NUMBER 2118015 Copyright (e) by Phase Zero Design Corp. AN Rights Reserved. DRAWING NAME INTERIOR DETAILS - WAIVER & COUNTER DRAWING NO. 2 WAIVER SECTION CABINET 7 ENLARGED WAIVER COUNTER PLAN SCHEDULES &NOTES A502 SCALE: 1 "=1'-0" SCALE: 1/2"=V-0" 4 0 �4 CV II II I I I I 0 EE I 1 II II CV i I I I rn I ( II II II II II II II II II II I1 ND PANEL, 2 A502 2'-6" SEAL TV (WALL HUNG) @ 6'-0" AFF ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: AJ CHECKED BY: RK PROJECT NUMBER 2118015 Copyright (e) by Phase Zero Design Corp. AN Rights Reserved. DRAWING NAME INTERIOR DETAILS - WAIVER & COUNTER DRAWING NO. 2 WAIVER SECTION CABINET 7 ENLARGED WAIVER COUNTER PLAN SCHEDULES &NOTES A502 SCALE: 1 "=1'-0" SCALE: 1/2"=V-0" 3 I ENLARGED PARTY ROOM PLAN SCALE: 1/2"=1'-0" INTERIOR MATERIAL & FINISHES FQR-1 WILSONART #1595-22, COLOR: TEXTURED BLACK FQR-2 WILSONART #7995-38, COLOR: STERLING ASH FQR-3 WILSONART #1595-60, COLOR: BLACK NOTES: MILLWORK HARDWARE TO BE BAR STYLE PULLS. BRUSHED SATIN. 161 PARTY ROOM MILLWORK ELEVATIONI I SCHEDULES I SCALE: 1/2"=l' -O" I, N (2) UPPER I I � ---------BLOCKING 2,-41/2" `° FOR- 1 BACKSPLASH I FOR -1 I � FOR -3 r% o FACE y II 2'-3" 01 ADJUSTABLE SHELVES CABINETS AS REQUIRED TOP/FACE r\ 1) ADJUSTABLE SHELF k c T 20 -VES ZED 15 I BREAKROOM MILLWORK SECTION 41 BREAKROOM MILLWORK SECTION I SCALE: 1"=l' -O" SCALE: 1"=I' -O" 2 k EN e C N BREAK ROOM MILLWORK ELEVATION SCALE: 1/2"=V-0" T-0" 4'-61/2" EXIST. MOP SINK AND WATER HEATER TO REMAIN. ARCHITECT 04, design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 vwvw.phasezenodesign oom CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 i I EXISTING I 103 JANITORS CLOSET"0/1 W 104 �4 a. BREAKROOM 103 FURNITURE F/I 2 A503 APPLIANCE F/1 BY TENANT (N.I.C) 6'-2" 1'-6" C.L. 7 ENLARGED BREAK ROOM PLAN SCALE: 1/2"=l' -O" APPLIANCE F/1 BY TENANT (N.I.C) MILLWORK CABINETS ABOVE I REV I DATE I DESCRIPTION/ COMMENTS SEAL ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: AJ CHECKED BY: RK PROJECT NUMBER 2118015 Copyright (c) by Phase Zero Design Corp. AN Rights Reserved. DRAWING NAME INTERIOR DETAILS - BREAKROOM/ PART ROOM DRAWING NO. A503 O) 3 v 0 LO T 0 00 I c c (D E 3 U O 0 DECK 24'-0" MEZZANINE 12'-0" j4 GROUND FLOOR 11V0'-0" DECK Y 24'-0" MEZZANINE 12'-0" jk GROUND FLOOR 0 0" 1'-0" 4 zo 141 MEZZANINE STAIR ELEVATION 131 MEZZANINE STAIR SECTION 1/2'=l' -O" 112"=1'-0" 1 I 2 SECTION @ PRATY ROOM ROLL -UP GARAGE DOOR 1/2" = 1'-0" AbU1 FUH MUHE INFO B.O. DECK h 24'-0" B.O. JOIST 21'-6" MEZZANINE OL 12'-0" A.C.T CEILING 9'-9" SUSPENDED 2X4 CEILING GLAZING BEYOND OUND FLOOR 0'-0" SECTION @ MEZZANINE 1/2" = 1'-0" B.O. DECK 24'-0" B.O. JOIST gt-\ 21'-6" MEZZANINE O 12'-0" � .C.T CEILING h 91-911 ALUMINUM FRAME WINDOWS SUSPENDED 2X4 CEILING )UND FLOOR h 0'-0" GENERAL NOTES: 1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS. IN THE EVENT OF OMISSION OF NECESSARY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE CONSTRUCTION MANAGER. 2. VERIFY SIZE, LOCATION, AND CHARACTERISTICS, OF ALL WORK AND EQUIPMENT TO BE FURNISHED BY OWNER OF OTHERS, WITH THE MANUFACTURER OR SUPPLIER BEFORE ANY CONSTRUCTION PERTAINING TO SAME IS BEGUN. 3. ALL DIMENSIONS ON PLANS ARE TO FACE OF FRAMING UNLESS OTHERWISE NOTED. 4. FIRE EXTINGUISHER: 10 CLASS ABC WITH UL RATING 4A-60BC. SURFACE MOUNTED ON WALL WITH MANUFACTURERS ALL STEEL WALL BRACKET. JL INDUSTRIES INC. (COSMIC 10E) OR APPROVED EQUAL WITH INSPECTION TAG AS REQUIRED BY LOCAL CODES. 5. ALL WORK SHALL BE IN COMPLIANCE FEDERAL, STATE AND LOCAL BUILDING CODES, REGULATIONS, ORDINANCES AND STANDARDS. 6. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. 7. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES AND ANY SHUT DOWN OF LIFE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. 8. THE G.C. SHALL ACQUAINT HIMSELF WITH THE BARRIER FREE REQUIREMENTS FOR THE STATE OF OH AND THE AMERICAN DISABILITIES ACT (ADA) AND SHALL INSURE THAT THIS SPACE WILL BE ACCESSIBLE ACCORDING TO THE STRICTER REQUIREMENTS OF THE APPLICABLE STANDARDS. 9. PATCH AND REPAIR ALL WALLS AND FLOORS AS NEEDED TO RECEIVE NEW FINISHES. 10. ALL DOORS ARE LOCATED 5" FROM ADJACENT WALL U.N.O. 11. ALL PARTITIONS ARE TYPE'A1' U.N.O. REFER TO PARTITION TYPES ON A601. 12. FIRE EXTINGUISHERS TO BE ,PUNTED TO WALL OR EXISTING COLUMNS. REFER TO 0002 FOR PLACEMENT. FIRE EXTINGUISHERS TO BE'LARSEN MP10'. 13. PLAN FOR LOCATING GRID AND FIXTURE REFERENCE ONLY. REFER TO ELECTRICAL DRAWINGS FOR FIXTURE SPECIFICATIONS AND WIRING. 14. MOUNT LIGHTING TO UNDER SIDE OF STRUCTURE. ADJUST SPACING BETWEEN FIXTURES AS NEEDED. 15. ACT GRID TO BE CENTERED IN EACH ROOM U.N.O. FLOOR PLAN KEY NOTES: PAN STAIR WITH CONCRETE FILL. STAIR TREADS AND RISERS TO BE FINISHED OMETAL i W/ JOHNSONITE VIRTR-40-RD (RAISED ROUND TREAD / RISER COMBO W/ VISUALLY IMPAIRED TREAD INSERT. COLOR: BLACK. O1-1/2" DIA. GALVANIZED METAL HAND RAIL. REFER TO FINISH SCHEDULE ON A131 3 GALVANIZED METAL PICKET STAIR RAILS, 1-1/2" DIA. METAL BOTTOM AND 3/4" DIA. BALUSTERS. REFER TO FINISH SCHEDULE ON A131 OTUBE STEEL POSTS BY STAIR MANUFACTURER. NOTES ARCHITECT 0 ldft IIIII= design 0 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezmDdesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 ix a a W Z o � tQ J O CL �o = O Q W LL z Q Fr W o Q r J U W cc Q IL REVISIONS REV DATE DESCRIPTION / COMMENTS SEAL ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: KH CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. All Rights Reserved. DRAWING NAME MEZZANINE & STAIR DETAILS DRAWING NO. A504 3 v, cpo LO co N c m 0 0 raw DOOR SCHEDULE WINDOW STANLEY FBB 179 / 1900 4-1/2" X - INGES COMMENTS AS SCHEDULED SIZE (NOMINAL) � GYPSUM BOARD FIRE HARDWARE THRESHOLD WINDOW WIDTH x HEIGHT x QUANTITY MATERIAL DOOR FRAME DETAILS STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS AS SCHEDULED COMMENTS ROCKWOOD 11047 SERIES 47 STRAIGHT SINGLE BAR SET, US 260 HARDWARE SET #4: SECURE =O Z 1-1/2" PR BUTT HINGES STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS O RATING SET NO. ALUMINUM / AN 4B/A601 DOOR SIZE (NOMINAL) ROCKWOOD K1050 34"X8" STAINLESS STEEL HARDWARE SET #5: FAMILY RESTROOM F- GLASS ALUMINUM STANLEY FBB 168, 5"x 4-1/2" (US26D) W/ NON REMOVABLE PINS 1 PRIVACY LEVER SET OB 3'-6" X 4'-0" 2 LOCATION HOLLOW WIDTH x HEIGHT x TYPE DOOR MATERIAL DOOR FINISH TYPE FRAME MATERIAL FRAME FINISH METAL STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS 1 DOOR BOTTOM O. 3 SILENCERS THICKNESS 1 PUSH PLATE ROCKWOOD 1 PULL HANDLE ROCKWOOD 1 O.H. CLOSER LCN 4041 SUPER SMOOTHEE (SURFACE MOUNTED) ALUM. 1 101 EVENT AREA O 1 EXISTING - - - _ _ _ _ _ 7 REPLACED KEYED CYLINDER. EXISTING HARDWARE TO REMAIN. V.I.F. 101 EVENT AREA O 1 EXISTING - - PT -02 - - PT -02 - - 7 REPLACED KEYED CYLINDER. EXISTING HARDWARE TO REMAIN. V.I.F. 102 EVENT AREA O 1 EXISTING - - PT -02 - - PT -02 _ _ 7 REPLACED KEYED CYLINDER. EXISTING HARDWARE TO REMAIN. V.I.F. 102 OFFICE 102 EXISTING - - PT -02 - - PT -02 - - 4 103 BREAKROOM 103 T-0" X T-0" X 1-3/4" WD -1 WOOD FOR -2 HM HM PT -02 4A/A601 - 4 104 JANITOR'S CLOSET 104 EXISTING - - PT -02 - - PT -02 - - 4 105 FAMILY RESTROOM 105 T-0" X T-0" X 1-3/4" HMI WOOD FOR -2 HM HM PT -02 4A/A601 - 5 106 MEN'S RESTROOM 106 3'-0" X T-0" X 1-3/4" HMI WOOD FOR -2 HM HM PT -02 4A/A601 - 6 107 WOMEN'S RESTROOM 107 T-0" X T-0" X 1-3/4" HM1 WOOD FOR -2 HM HM PT -02 4A/A601 - 6 108 STORAGE 108 T-0" X T-0" X 1-3/4" WD -1 WOOD FOR -2 HM HM PT -02 4A/A601 - 4 109 PARTY PREP KITCHEN 109 T-0" X 7'-0" X 1-3/4" WD -1 WOOD FOR -2 HM HM PT -02 4A/A601 - 4 110 PARTY ROOM C10 3'-0" X T-0" X 1-3/4" FG -1 ALUM/GL CLEAR ANODIZED ALUM ALUM CLEAR ANODIZED - - 3 110 PARTY ROOM10 10'-0" X 8'-0" MTL-1 GLOSSY WHITE - - - - - - VENDOR SUPPLIED WAYNE DALTON ROLLING SERVICE DOOR, SERIES 780 CD 111 PARTY ROOM ID T-0" X 7'-0" X 1-3/4" FG -1 ALUM/GL CLEAR ANODIZED ALUM ALUM CLEAR ANODIZED - - 3 111 PARTY ROOM 1 1 10'-0" X 8'-0" MTL-1 GLOSSY WHITE - - - - - - VENDOR SUPPLIED WAYNE DALTON ROLLING SERVICE DOOR, SERIES 780 CD 112 PARTY ROOM CO 6 T-0" X T-0" X 1-3/4" FG -1 ALUM/GL CLEAR ANODIZED ALUM ALUM CLEAR ANODIZED - - 3 113 STORAGE 13 (2) T-0" X T-0" X 1-3/4" WD -1 WOOD FOR -2 HM HM PT -02 4A/A601 - 4 113 STORAGE 13 EXISTING - - _ _ _ _ _ - 7 REPLACED KEYED CYLINDER. EXISTING HARDWARE TO REMAIN. V.I.F. WINDOW SCHEDULE WINDOW STANLEY FBB 179 / 1900 4-1/2" X - INGES COMMENTS AS SCHEDULED SIZE (NOMINAL) � GYPSUM BOARD ROCKWOOD jT7�TRAIGHT SINGLE BAR SET, STAINLESS STEEL z THRESHOLD WINDOW WIDTH x HEIGHT x QUANTITY MATERIAL FRAME FINISH DETAILS GLAZING STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS AS SCHEDULED THICKNESS ROCKWOOD 11047 SERIES 47 STRAIGHT SINGLE BAR SET, US 260 HARDWARE SET #4: SECURE =O Z 1-1/2" PR BUTT HINGES STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS O 15'-10" X 9'-0" 3 ALUMINUM / CLEAR ANODIZED 4B/A601 TEMPERED KAWNEER INFRAME INTERIOR STOREFRONT, OR EQUAL ROCKWOOD K1050 34"X8" STAINLESS STEEL HARDWARE SET #5: FAMILY RESTROOM F- GLASS ALUMINUM STANLEY FBB 168, 5"x 4-1/2" (US26D) W/ NON REMOVABLE PINS 1 PRIVACY LEVER SET OB 3'-6" X 4'-0" 2 GLASS HOLLOW 4A/A602 TEMPERED MOUNTED AT 3'-6" A.F.F. KICK PLATE (BOTH SIDES) ROCKWOOD K1050 34"X8" STAINLESS STEEL HARDWARE SET #6: MULTI STALL RESTROOM 3 METAL STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS 1 DOOR BOTTOM DOOR & HARDWARE SCHEDULE METAL STUD FRAMING 6" MTL STU AT 16" O.C. FULL HEIGHT GWB TO UNDERSIDE OF FINISHED DECK AS SCHEDULED GYPSUM BOARD 3-5/8" MTL STUD--,,,,_ HOLLOW METAL #20 GA. STL. STUDS @ 16" ACOUSTICAL CEILING DOOR FRAME O.C. W/ FIBER BLANKET AS SCHEDULED o AS HEIGHT GWB w TO 6" ABOVE ACT EXTEND GYP. BD. INTO p SEALANT AND DOOR ASFRAME MIN. LLI BACKER ROD SCHEDULED ­____\ V AT EACH SIDE STL.STUD TRACK o7 e cn WINDOW a SYSTEM AS HEAD HEAD SCHEDULE JAMB METAL STUD FRAMING AT 16" O.C. GYPSUM BOARD #20 GA. STL. STUDS @ 16" O.C. W/ FIBER BLANKET EXTEND GYP. BD. INTO FRAME J" MIN. STL. STUD TRACK 5/8" 3-5/8" MTL S' 6" MTL ST m r r _ AS SCHEDULED JAMB ► ARE SET #1 EMERGENCY EXITS 1 CONTINU GE 1 O.H. CLOSER 1 EXIT DEVICES 1 RIM CYLINDER 1 THRESHOLD 1 SET WEATHERSTRIPPING 1 DOOR A CK PLATE (INTERIOR) ►R T #2: MAIN ENTRANCE BATTALION LCN 4041 SUPER SMOOTHEE (SURFAC TED) ALUM. VON DUPRIN 5547 -NL- M-CONC. VERTICAL ROD US26D YAL S26D KAWNEER (BUTT -HU KAWNEER DETEX EA -2500 (FLUSH MOUNT) ROCKWOOD K1050 34"X8" STAINLESS STEEL 3 FINISHED STANLEY FBB 179 / 1900 4-1/2" X - INGES 1 AS SCHEDULED 041 S THEE (SURFACE MOUNTED) ALUM. � GYPSUM BOARD ROCKWOOD jT7�TRAIGHT SINGLE BAR SET, STAINLESS STEEL z THRESHOLD 950/ NGP g HOLLOW METAL 202N / NGP a DOOR FRAME 1-1/2" PR BUTT HINGES STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS AS SCHEDULED PUSH - PULL ROCKWOOD 11047 SERIES 47 STRAIGHT SINGLE BAR SET, US 260 HARDWARE SET #4: SECURE =O Z 1-1/2" PR BUTT HINGES STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS w LOCKSET (TOWER) YALE 5405 LN W/ LEVER STYLE AUGUSTA AU (US26D) p DOOR— LCN 4041 SUPER SMOOTHEE (SURFACE MOUNTED) ALUM. O AS SCHEDULED ROCKWOOD K1050 34"X8" STAINLESS STEEL JAMB METAL STUD FRAMING AT 16" O.C. GYPSUM BOARD #20 GA. STL. STUDS @ 16" O.C. W/ FIBER BLANKET EXTEND GYP. BD. INTO FRAME J" MIN. STL. STUD TRACK 5/8" 3-5/8" MTL S' 6" MTL ST m r r _ AS SCHEDULED JAMB ► ARE SET #1 EMERGENCY EXITS 1 CONTINU GE 1 O.H. CLOSER 1 EXIT DEVICES 1 RIM CYLINDER 1 THRESHOLD 1 SET WEATHERSTRIPPING 1 DOOR A CK PLATE (INTERIOR) ►R T #2: MAIN ENTRANCE BATTALION LCN 4041 SUPER SMOOTHEE (SURFAC TED) ALUM. VON DUPRIN 5547 -NL- M-CONC. VERTICAL ROD US26D YAL S26D KAWNEER (BUTT -HU KAWNEER DETEX EA -2500 (FLUSH MOUNT) ROCKWOOD K1050 34"X8" STAINLESS STEEL 3 HINGE STANLEY FBB 179 / 1900 4-1/2" X - INGES 1 O.H. CLOSER 041 S THEE (SURFACE MOUNTED) ALUM. 1 PUSH/PULL BAR ROCKWOOD jT7�TRAIGHT SINGLE BAR SET, STAINLESS STEEL 1 THRESHOLD 950/ NGP 1 SWEEP 202N / NGP HARDWARE SET #3: PUBLIC; PARTY ROOM AND PARENT LOUNGE 3 1-1/2" PR BUTT HINGES STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS 1 PUSH - PULL ROCKWOOD 11047 SERIES 47 STRAIGHT SINGLE BAR SET, US 260 HARDWARE SET #4: SECURE � J LL 1-1/2" PR BUTT HINGES STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS 1 LOCKSET (TOWER) YALE 5405 LN W/ LEVER STYLE AUGUSTA AU (US26D) 1 O.H. CLOSER LCN 4041 SUPER SMOOTHEE (SURFACE MOUNTED) ALUM. 1 1 KICK PLATE (BOTH SIDES) ROCKWOOD K1050 34"X8" STAINLESS STEEL HARDWARE SET #5: FAMILY RESTROOM F- W 1-1/2" PR BUTT HINGES STANLEY FBB 168, 5"x 4-1/2" (US26D) W/ NON REMOVABLE PINS 1 PRIVACY LEVER SET YALE 5402LN 1 O.H. CLOSER LCN 4041 SUPER SMOOTHEE (SURFACE MOUNTED) ALUM. 3 SILENCERS IVES SR64 1 KICK PLATE (BOTH SIDES) ROCKWOOD K1050 34"X8" STAINLESS STEEL HARDWARE SET #6: MULTI STALL RESTROOM 3 1-1/2" PR BUTT HINGES STANLEY FBB 168, 5" x 4-1/2" (US26D) W/ NON REMOVABLE PINS 1 DOOR BOTTOM PEMKO 210 AV 3 SILENCERS IVES SR64 1 PUSH PLATE ROCKWOOD 1 PULL HANDLE ROCKWOOD 1 O.H. CLOSER LCN 4041 SUPER SMOOTHEE (SURFACE MOUNTED) ALUM. 1 KICK PLATE (BOTH SIDES) ROCKWOOD K1050 34"X8" STAINLESS STEEL HARDWARE SET #7: REUSED EXISTING DOORS 1 KEYED CYLINDER SCHLAGE LINE OF STRUCTURE ABOVE SUSPENDED CEILING AS SCHEDULED MTL STUD FRAMING FULL HEIGHT GWB GWB 6" ABOVE SUSPENDED CEILING RUBBER COVE BASE AS SPECIFIED SEALED CONCRETE FLOOR AS SPECIFIED LINE OF STRUCTURE ABOVE SUSPENDED CEILING AS SCHEDULED MTL STUD FRAMING FULL HEIGHT GWB GWB 6" ABOVE SUSPENDED CEILING RUBBER COVE BASE AS SPECIFIED SEALED CONCRETE FLOOR AS SPECIFIED GENERAL NOTES 1. REFER TO SHEET A101 FOR FLOOR PLAN. 2. ALL DOOR HARDWARE SHALL COMPLY WITH FEDERAL AND STATE ACCESSIBILITY REQUIREMENTS 3. PROVIDE TWO (2) KEYS FOR EACH LOCK. ALL KEYS SHALL BE TURNED OVER TO MAINTENANCE SUPERINTENDENT. 4. ALL THRESHOLDS TO BE ANCHORED TO CONCRETE FLOOR. 5. ELECTRICAL SERVICE AND HARD WIRING TO BE SUPPLIED BY ELECTRICAL CONTRACTOR. 6. GENERAL CONTRACTOR SHALL PREPARE OPENINGS TO ACCEPT DOOR PACKAGE. 7. GENERAL CONTRACTOR TO FIELD VERIFY OPENING DIMENSION PRIOR TO ORDERING PACKAGE. 8. DOOR PACKAGES WILL BE ORDERED AND BUILT IN ACCORDANCE TO APPROVED SHOP DRAWINGS. 9. ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 10. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE AND SWING IN THE DIRECTION OF TRAVEL. 11. ON ALL EXTERIOR DOORS FULL LENGTH LATCH GUARDS TO BE WELDED AND DRIP CAPS TO BE PAINTED TO MATCH DOOR AND FRAME. 12. ANY EXPOSED STRUCTURAL MEMBERS TO RECEIVE PRE -FINISHED BRAKE METAL WRAP, COLOR TO MATCH STOREFRONT. 13. STOREFRONT CONTRACTOR TO PROVIDE ALL BRAKE METAL WRAPS AND ENCLOSURES. 14. DIMENSIONS ONLY HAVE 1/8" TOLERANCE. DO NO EXCEED TOLERANCE. 15. ALL ITEMS LISTED ARE INCLUDED IN LANDLORD SCOPE OF WORK UNLESS NOTED OTHERWISE. 16. PAINT EXTERIOR TO MATCH ADJACENT WALL COLOR. INTERIOR DOOR FRAMES TO BE PAINTED PT -02 WINDOW NOTES: A. FIELD VERIFY ALL WINDOW OPENINGS DIMENSIONS PRIOR TO ANY FABRICATION; NOTIFY ARCHITECT OF ANY DISCREPANCIES. B. GLASS DOORS ARE SHOWN ON DOOR SCHEDULE. HARDWARE NOTES: A. KICKPLATES SHALL BE 8" HIGH X 2" LESS THAN WIDTH OF DOOR UNLESS NOTED OTHERWISE. B. ALL CLOSERS SHALL MEET ADA REDUCED OPENING FORCE REQUIREMENTS. C. FINISH ON ALL HARDWARE TO BE CHROME(US26D) UNLESS NOTED OTHERWISE. D. CAULK ALL AROUND HEAD, JAMB & SILL, AT JUNCTURE OF H.M. FRAMES TO WALL FINISH. E. CONTRACTOR IS TO VERIFY FRAME HEIGHTS BASED ON TOP OF SLAB AND FINISH FLOOR CONDITIONS AT EACH FRAME. F. CONTRACTOR IS TO PROVIDE MANUFACTURER'S STANDARD REINFORCING CLIPS AT FRAME CORNERS. G. PROVIDE" UNDERCUT AT BOTTOM OF DOORS UNLESS NOTED OTHERWISE. NOTES LINE OF STRUCTURE ABOVE MTL STUD FRAMING 1 LAYER OF 5/8" GWB AT EACH SIDE. USE WATER RESISTANT GWB IN WET AREAS RUBBER COVE BASE AS SPECIFIED SEALED CONCRETE FLOOR AS SPECIFIED J W I6. I W DOOR AS U SCHEDULED FLOOR AS SCHEDULED Q WINDOW INTERIOR PARTITION INTERIOR PARTITION INTERIOR PARTITION INTERIOR PARTITION SYSTEM SCHEDULE 3 5/8" STUD C� 3 5/8" STUD FBI]3 5/8" STUD Al 3 5/8" STUD .d A a. G G INTERIOR PARTITION D2 INTERIOR PARTITION CZ INTERIOR PARTITION g2 6" STUD INTERIOR PARTITION SILL EXISTING SLAB 6 STUD 6 STUD [A2] 1518 STUD SILL ODOOR DETAILS O INTERIOR STOREFRONT DETAILS 4 DOOR AND WINDOW DETAILS 131 PARTITION TYPES SCALE: 3/4"=1'-0" SCALE: 314"=1'-0" 2" 3'- 2" N 0 (V N M 0 HOLLOW METAL FRAME TEMPERED GLASS 2 WINDOW TYPES SCALE: 1/4"=l' -O' 15'-0" 2" 2" 2" 2- 3'-0" EQ. EQ. EQ. CV 00 N 0 r iT 0 ALUMINUM FRAME TYPE COLOR: CLEAR ANODIZED ALUMINUM TEMPERED GLASS 2" 7 DOOR TYPES SEE DOOR SCHEDULE I WD1 SOLID CORE LAMINATED WITH FOR -2 SEE DOOR SCHEDULE 4" 6 o� c_:' \ SEE DOOR 211 SCHEDULE 2„ FG1 ALUM STOREFRONT ALUMINUM WITH FULL LITE/ ALUMINUM STOREFRONT COLOR: CLEAR ANODIZED ALUMINUM ANODIZED ALUMINUM LINE OF STRUCTURE ABOVE SUSPENDED CEILING AS SCHEDULED MTL STUD FRAMING 1 LAYER OF 5/8" GWB AT ONE SIDE. USE WATER RESISTANT GWB IN WET AREAS RUBBER COVE BASE AS SPECIFIED ARCHITECT AOL 0 0 design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.omaz&mdesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 U SEALED CONCRETE FLOOR AS SPECIFIED a SEE DOOR 2„ SCHEDULE 2„ N 4 F HM HOLLOW METAL FRAME TYPE PRIMER/PAINT FINISH SEAL Y Q a w z o O � J LL CL F- o r Za o �n F- W o O F- H J Q DATE I DESCRIPTION/ COMMENTS ISSUED FOR: PERMIT -BID ISSUED DATE: 04.04.2018 DRAWN BY: KH CHECKED BY: RK PROJECT NUMBER: 2118015 Copyright (c) by Phim Zero Design Corp. AN Rights Reserved. DRAWING NAME SCHEDULES AND DETAILS DRAWING NO. A601 GENERAL NOTES: GENERAL 1'-10 1/2" \ 1. DESIGN PERFORMED IN ACCORDANCE WITH AISI "SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS", 2012 EDITION 2. DIMENSIONS HAVE BEEN DETERMINED FROM THE CONTRACT DOCUMENTS AND ARE USED HEREIN FOR REFERENCE ONLY. ALL DIMENSIONS SHALL BE FIELD VERIFIED BEFORE ERECTION. 3. THIS SHOP DRAWING PACKAGE SHALL BE REVIEWED BY THE ENGINEER OF RECORD AND/OR ARCHITECT PRIOR TO ORDERING OF MATERIALS AND INSTALLATION. 4. THE PRIMARY STRUCTURES ADEQUACY TO SUPPORT THE COLD FORMED FRAMING AND LOADS IMPOSED BY IT ARE THE RESPONSIBILITY OF THE ENGINEER OF RECORD. 5. COLD -FORMED STEEL GENERAL REQUIREMENTS, CLASSIFICATION OF MATERIALS, INSTALLATION, QUALITY CONTROL, CONTRACTUAL RELATIONS AND RESPONSIBILITIES ARE PER THE CODE OF STANDARD PRACTICE FOR COLD -FORMED STEEL STRUCTURAL FRAMING, AISI S202-11. MATERIAL: 1. COLD FORMED FRAMING MEMBERS SHALL BE FORMED FROM STEEL CORRESPONDING TO AISI SPECIFICATIONS WITH A MINIMUM YIELD STRENGTH OF 33 KSI FOR 43 MIL AND 50 KSI FOR 54 MIL AND GREATER. 2. COLD FORMED FRAMING MEMBERS SHALL BE FORMED FROM STEEL WITH A G-60 GALVANIZING MEETING THE MINIMUM REQUIREMENTS OF ASTM A525. 3. ALL FRAMING SHALL BE THE TYPE, SIZE AND THICKNESS AS SHOWN ON THESE PLANS AND BE MANUFACTURED BY AN SSMA APPROVED MANUFACTURER. NO SUBSTITUTIONS ALLOWED WITHOUT THE ENGINEERS WRITTEN APPROVAL. 4. MEMBER THICKNESSES ARE BASED ON DESIGN FOR STRENGTH AND DEFLECTION. REFER TO WINDOW/CURTAIN WALL NOA FOR REQUIRED MINIMUM THICKNESS OF COLD FORMED STEEL STUDS. 5. DECKING SHALL BE APA RATED 11/8" NON-COMBUSTIBLE PLYWOOD SHEATHING WITH A MINUMUM SUBFLOOR SPAN OF 48". JOIST SHALL BE ATTACHED TO METAL STUDS @ 6" OC AT PANEL EDGES AND 12" OC INTERIOR. rinKIAIGnTInKl0 1. SDS SCREW - 1.1. #10 (BUILDEX #10-16 W/ #3 DRILL POINT SHEET METAL SCREWS); 1.2. #12 (BUILDEX #12-14 W/ #2 DRILL POINT SHEET METAL SCREWS); 1.3. #14 (BUILDEX 1/4-28 W/ #5 DRILL POINT SHEET METAL SCREWS); 1.4. ALL SCREWS SHALL BE OF ADEQUATE LENGTH TO FULLY ENGAGE ALL MEMBERS BEING FASTENED WITH THREE EXPOSED THREADS OUT THE BACK OF CONNECTION. 1.5. MINIMUM SCREW SPACING AND END DISTANCE SHALL NOT BE LESS THAN 3.0 X 0 OF SCREW. EDGE DISTANCE SHALL NOT BE LESS THAN 1.5 X 0 OF SCREW. 2. HILIT "X -U" - 2.1. INDICATES 0 OF HILIT "X -U" LOW VELOCITY POWDER ACTUATED FASTENER INSTALLED PER MANUFACTURES RECOMMENDATIONS W/ MIN. EMBEDMENT NOTED ON DETAILS FOR CONCRETE AND FULL PENETRATION FOR STEEL. MIN SPACING AND EDGE DISTANCE PER MANUFACTURERS RECOMMENDATIONS AND ESR -2269. FRAMING 1. 2. 3. 4. 5. ALL FIELD CUTTING OF STUDS MUST BE DONE BY SAWING OR SHEARING. TORCH METHODS OF CUTTING ARE NOT ACCEPTABLE. NO NOTCHING OR COPING OF STUDS IS ALLOWED, UNLESS STATED ON DRAWINGS. SPLICING OF WALL STUDS IS NOT PERMITTED, UNO. ENDS OF STUDS MUST BE CUT SQUARELY FOR ATTACHMENT TO PERPENDICULAR FRAMING WHICH MUST HAVE FULL BEARING ON STRUCTURE. TEMPORARY BRACING SHALL BE PROVIDED BY THE FRAMING CONTRACTOR AND REMAIN IN PLACE UNTIL CONTRACTOR DEEMS FRAMING IS STABLE WITHOUT BRACING. DESIGN INFORMATION: LOCATION: SANFORD, FL DESIGN BUILDING CODE: 2017 BLDG CODE, 6th EDITION DESIGN LOADS: PLATFORM FRAMING (24" O.C. AREAS): DEAD LOAD: 10 PSF LIVE LOAD: 100 PSF PLATFORM FRAMING (12" O.C. AREAS): DEAD LOAD: 10 PSF LIVE LOAD: 150 PSF MEZZANINE STORAGE FRAMING - DEAD LOAD: 5 PSF LIVE LOAD: 125 PSF COLD FORMED STEEL MEMBER THICKNESS TABLE SSMA MIL THICKNESS GAGE THICKNESS (FOR REFERENCE ONLY) DESIGN THICKNESS 18 25 GA 0.0188" 27 22 GA 0.0283" 30 20 GA (DRYWALL) 0.0312" 33 20 GA (STRUCTURAL) 0.0346- 43 18 GA 0.0451" 54 16 GA 0.0566" 68 14 GA 0.0713" 97 12 GA 0.1017" 118 10 GA 0.1241" PRODUCT IDENTIFICATION EXAMPLE 600 S 162 - 43 (Fy = 50KSI) LEGEND: YIELD STRENGTH (NON -TYPICAL) -MATERIAL THICKNESS (MILS) -FLANGE WIDTH (vloo") -MEMBER SHAPE S - STUD T -TRACK 1J - CHANNEL F - FURRING CHANNEL L - ANGLE MEMBER DEPTH (Y100") HATCH INDICATES AREA OF UPPER PLATFORM @ 5'-1 a". NOTE: VERIFY ALL DIMENSIONS SHOWN WITH ARCHITECT BEFORE FABRICATION. ELEVATED FLOOR FRAMING PLAN (REF: A.1 CMU WALL BY OTHERS. 15'W X 9'H STOREFRONT W/ DOOR & 1 TRANSOM, TYP; REFER TO OPENING. FARMING CHART AND DETAILS ON L3.00. J 600S162-33 @ 24" O.C.; CONNECT TO JOIST 10'W ROLL -UP GARAGE ABOVE W/ 600SLT250-33 W/ (1) #10SDS EA STUD DOOR, TYP; REFER TOD FLANGE AND (1) #10SDS @ 12" O.C. TO JOIST. OPENING FRAMING REFER TO 1/1-3.00 (SIM) FOR CONNECTION OF CHART AND DETAILS ONBOTTOM TRACK TO CONC. SLAB. L3.00. Lj 4 600S162-33 @ 24" O.C.; CONNECT TO JOIST ABOVE W/ 600SLT250-33 W/ (1) #10SDS EA STUD FLANGE AND (1) #10SDS @ 12" O.C. TO JOIST. REFER TO 1/1-3.00 (SIM) FOR CONNECTION OF BOTTOM TRACK TO CONC. SLAB. MEZZANINE FLOOR FRAMING PLAN ARCHITECT r a F r'-,_ po, design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezemdesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD, BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL $ PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 0 U W 0 Ir Ira Q 0 Q W z O r 00 V_ J LL 0 LL z Q ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 PROJECT NUMBER: 2118015 y ba - .- _4 f L1.00 CONT 60OT125-43 W/ (1) #12 SDS EA SIDE. CONT 362T125-54 W/ (1) #12 SDS EA SIDE. -� WALL AT SIM CONDITION. NOTES: 1. REFER TO DETAIL C/L2.00 FOR FLOOR JOIST BRIDGING REQUIREMENTS 2. SHEATHING BY OTHERS. NOT SHOW HEREIN. 1 1/8" FIRE RETARDANT PLYWOOD DECK. +2'-113/4" M r FLOOR JOIST (SEE PLAN) @ 24" OC (MAX) N W/ (2) #12 SDS TO VERT WALL STUD. 362S162-43 @ 24" OC FF 0'-0" _ - - _ - - _ (MAX) CENTERED UNDER ------ FLOOR STUD. CONT 362T125-43 W/ (1) #12 SDS EA SIDE AND (1) 0.157"0 HILT -XU W/ 1" EMBED @ 8" OC OR (2) @ 16" OC INTO EXIST CONC FLOOR. SECTION (LOW PLATFORM) SCALE: 3/4"=1'-0" 1 1/8" FIRE RETARDANT PLYWOOD DECK. 600S162-43 @ 24" OC (MAX) UP -- ----------- -----FF 0,_011------- ------- END INFILL 250S162-43 @ 40OS162-43 BY OTHERS. END OF RAMP. r5_%SECTION (RAMP END) oo SCALE: 3/4"=1'-0" CONT 60OT125 MATCH THICKNESS TO FLOOR JOIST W/ (1) #12 SDS INTO EA. FLANGE. ATTACH TO FLOODS JOIST W/ (2) #12 S @ 16" O.C. ICONT 60OT125-54 W/ (1) #12 SDS EA SIDE. 1 1/8" FIRE RETARDANT PLYWOOD DECK. +2'-113/4" , +5'-1 3/4" FLOOR JOIST (SEE zt PLAN) @ 24" OC (MAX) W/ (2) #12 SDS TO VERT N WALL STUD. REF z L2.00 - 0'-0" _______ --------------------------------------' REF '2 12.00 91 SECTION CLOW/HIGH 2.00 SIMPSON STRO SUBH3.25 BRIDI CONNECTOR ATTACH TO U-( W/ (2) #10 SDS PLATFORM 1-1/2" x 54 MIL., U -CHANNEL BRIDGING @ 4' OC. STUD SCALE: 3/4"=1'-0" (2) FLOOR JOIST ON TOP OF WALL W/ (2) #12 TO TOP TRACK, TYP 362T125-54 CONT. 1 1/8" FIRE RETARDANT PLYWOOD DECK. - DETAIL (U—CHANN CONNECTIONS) FF 0. 362S162-43 @ 16" 362S162-43 @ 16" '8" FIRE RETARDANT 'WOOD DECK. CONT L2x2x43 M #12 SDS TO +2'-11 3/4" EACH STUD. u u C a FLOOR JOIST (SEE PLAN) @ 24" OC (MAX) ATTACH FLOOR DECK W/ (1)#12 SDS a @ 16 "OC. & JOIST TO TOP u TRACK W/ (2) #12 SDS SECTION .(LOW PLATFORM 5'-0" /- FLOOR JOIST (SEE PLAN) @ 24" OC (MAX) W/ (2) #12 SDS TO VERT WALL STUD. SCALE: 3/4"=1'-0" l �(2) #12 SDS @ EA STUD --- --- ------------- -------- 0'-0" -- EF 4 LZ.00 REF 4 12.00 FF 0'-0 BRACING @ 4' O.C. CONT 60OT143-54 W/ (1) #12 SDS EA SIDE. n c 151 TRFAMR n 11" = 4'_7" SECTION (RAMP LANDING) / 7\ 1-1/2" x 54 MIL., U -CHANNEL 3RIDGING CONNECTED TO CLIP W/ (2) #14 SDS. WALL STUD - REFER TO DETAILS. 1-1/2" x 1-1/2"x 54 MIL., CLIP ANGLE FASTENED TO WALL STUD W/ (4) #14 SDS. ANGLE LENGTH SHALL NOT BE LESS THAN STUD DEPTH, MINUS 1/2" ALTERNATE BRIDGING EL BRIDGING ---------- SCALE: NTS SCALE: 3/4"=1'-0"�-o CONT 125 TRACK 1 1/8" FIRE RETARDANT MATCH DEPTH AN PLYWOOD DECK. THICKNESS WITH FLOOR JOIST W/(1)#12 +5'-1 3/4" SDS EA FLANGE. FLOOR JOIST (SEE PLAN) @ 24" OC (MAX) W/ (2) #12 SDS TO VERT WALL STUD. --REF A BLK'G MID L200 HEIGHT 362S 162-43 @ 24" OC (MAX) CENTERED UNDER - - - - - FLOOR STUD. CONT 362T162-43 W/ (1) #12 SDS EA SIDE AND (1) 0.157"0 HILT -XU W/ 1" EMBED @ 8" OC OR (2) @ 16" OC INTO EXIST CONC FLOOR SECTION (HIGH PLATFORM" SCALE: 3/4"=1'-0" NOTE: PLACE BRACING AT 16'-0" OC ALONG INTERIOR SUPPORT WALLS. ^r%k IT -rM A /N1/ SDS AT EACH END OF PLATE. B1 DETAIL (BRAC CONT 60OT125-54 W/ (1) #12 SDS EA FLANGE. v M r _1 zo SECTIO 1 1/8" FIRE RETARDANT PLYWOOD DECK. AK +2'-11 3/4" REF 1 L2.00 VV,. 1 VVL 1 ILV-TV Y"/ `1, Tr 1L VL/V Ll V .lILJL REF AND(1)0. 7"OHILT-XU W/ 1" EMBED @ 8" OC OR (2) @ 16" OC INTO EXIST CONC FLOOR N (LOW PLATFORM W STAIR SCALE: 3/4"=1'-0" (2) #12 SDS FROM FLOOR JOIST TO TOP CHORD. 1 1/8" FIRE RETARDANT PLYWOOD DECK. +2'-11 3/4" +5'-1 3/4" FLOOR JOIST (SEE PLAN) @ 24" OC (MAX) W/ (2) #12 SDS TO VERT WALL STUD. REF z -------- REF '2 rz o0 SECTION (LOW/HIGH PLATFORMSCALE: 3/4"=1'-0" (2) #12 SDS @ 16" O.0 FROM FLOOR JOIST TO TOP CHORD. 1 1/8" FIRE RETARDANT PLYWOOD DECK. +5'-1 3/4" FLOOR JOIST (SEE PLAN) @ 24" OC (MAX) W/ (2) #12 SDS TO VERT WALL STUD. -REF A 12.00 REF 10 FF 0'-0" REF 1 L2.00 SECTION (HIGH PLATFORM SCALE: 3/4"=1'-0 1 1/8" FIRE RETARDANT PLYWOOD DECK. +2'-11 3/4" 111 +5'-1 3/4" ST r r CV --- FF0'-0"___ _ 14 GA PLATE W/ (5) #12" INTO STUD AND TRACK ING) SCALE: 3/4"=1'-0" FLOOR JOIST; REFER TO DETAILS. 1 1/8" FIRE RETARDANT PLYWOOD DECK. [5051[91LIW CONT 60OT125-43 W/ (1) #12 SDS EA SIDE. CONT 362T125-43 W/ (1) #12 SDS EA SIDE. U) w REF 2 1,2.00 1 1/8" FIRE RETARDANT PLYWOOD DECK. Ak +2'-11 3/4" FLOOR JOIST (SEE PLAN) @ 24" OC (MAX) W/ (2) #12 SDS TO VERT WALL STUD. REF REF L200 L2.00 0 1 ------------------------------- ------ FF 0'------------ CONT 362T125-43 W/ (1) #12 SDS EA SIDE REF 1 AND (1) 0.157"0 HILT -XU W/ 1" EMBED @ 8" LZ.DO OC OR (2) @ 16" OC INTO EXIST CONC FLOOR SECTION (RAMP) CONT 60OT125-43 W/ (1) #12 SDS EA SIDE. CONT 362T125-43 W/ (1) #12 SDS EA SIDE. U) CONT L2x2x43 MIL w W/ (2) #12 SDS TO U a EACH STUD. + + U) + + J Q + + ++ ++ ++ (2) #12 SDS @ 16" O.0 FROM FLOOR JOIST TO TOP CHORD. 1 1/8" FIRE RETARDANT / PLYWOOD DECK. Ask +5'-13/4" �- FLOOR JOIST (SEE REF 3 PLAN) @ 24" OC (MAX) L2.00 W/ (2) #12 SDS TO VERT (4) #12 SDS, TYP. WALL STUD. M r Lo 10 M CONT 362T125-43 W/ (1) #12 SDS EA FLANGE & 04 ATTACH TO DECKING W/ (1) #12 @ 6" O.C.. LAST FLOOR JOIST TO BE ATTACHED TO EA VERT STAIR STUD W/ (2) #12 SDS. --- - 0'-0----------- -- - ---- ------------------------------------------ CONT CONT STUDS AT STAIR 1 ENDS DOWN TO CONCRETE. REF S-2 $ SECTION STAIR LOW TO HIGH PLATFORM) 1" NON-COMBUSTIBLE DECK. NOTE: DETAIL APPLIES TO ALL FLOOR JOIST SPANS GREATER THAN 5'-0" C1 DETAIL (FL BRIDGING SCALE: NTS 1 1/8" FIRE RETARDANT PLYWOOD DECK. +5'-13/4" FLOOR JOIST (SEE PLAN) @ 24" OC (MAX) W/ (2) #12 SDS TO VERT WALL STUD. v ch r 1 Z -REF A BLK'G MID LZ.00 HEIGHT REF �q2 46.00 0'-0" REF 1 L2.00 SECTION (HIGH PLATFORM LOWP LATFO R M) SCALE: 3/4"=1'-C SCALE: 3/4"=1'-0" SCALE: 3/4"=1'-0" ER Z46e. :y\cENS':•... ' o. 592 5 s wOF ARCHITECT Aftphiu,,,,�t:;e zeAro IW design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezemdesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 J 0 a W D H U W a 0 a 0of J LL ofd Qce =0 W u - z_ z Q O U) r co r ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 PROJECT NUMBER: 2118015 L2.00 CMU WALL BY OTHERS. 1000T200-54 RIM TRACK W/ (2)#10SDS EA STUD FLANGE AND (1) a"0 X 1" ITW TAPCON @ 8" O.C. TO CMU. STEEL DECK BY OTHERS; 30 MIL MIN. PARTY ROOM WALL SECTION SCALE: N.T.S. (2)600S200 - JAN 1000S162-54 EA SIDE OF JAMB. (4) #10SDS 4" APART IN SQUARE PATTERN, TYP. DOUBLE JAMB TO JOIST 600S162-54 @ 12" O.C. 600T125-54 W/ (1) #10SDS EA STUD FLANGE. (2) #10 SDS @ 12" O.C. NOTE: FOR CONNECTIONS TO 97 MIL CFS, REFER TO SCREW MANUFACTURER'S GUIDANCE FOR PROPER SCREW SIZE AND DRILL TIP. C-, 3.00 600S162-33 @ 2 600T125-33 W/ (1) #10S EA STUD FLAN( (2) #10 SDS @ 12" OC. (2)600S200-54 JAMB. BOX HEADER = (2)600S200-97 W/ (2)600T125-97 W/ (1) #10SDS EA FLANGE @ 6" O.C. AS SHOWN; STUDS MUST BE POSITIONED WITH WEBS VERTICAL AS SHOWN. SCALE: N.T.S. 8"x3.25" 54 MIL CFS PLATE EA SIDE OF JAMB @ 4' O.C. WITH (10) #10SDS PER PLATE. (2)2"X2"X6"54 MIL CFS CLIP ANGLES WITH (4) #10SD EA LEG. BOX HEADER TO JAMB (2)600S200-54 JAMB. (1) #10SDS @ 6" O.C. 600S162-33; OPTIONAL CAPPED W/ 600T125-54. SCALE: N.T.S. 8"x3.25" 54 MIL CFS PLATE EA SIDE OF JAMB @ 4'0.C. WITH (10) #10SDS PER PLATE. (2)2"X2"X6"54 MIL CFS CLIP ANGLES WITH (4) #10SD EA LEG INFILL FRAMING AT GARAGE SCALE: N.T.S. A' s—oo 10OS162-54 BLOCKING COPED AT ENDS; LOCATE AT FIRST AND SECOND SPACES EA END, AND @ 10'-0" O.C. BETWEEN. ATTACH TO JOISTS W/ #10SDS AS SHOWN. ATTACH PLYWOOD DECK TO BLOCKING W/ (1) #10SDS @ 6" O.C. 1 8' FIRE RETARDANT PLYWOOD DECK ATTACHED TO JOISTS W/ #10SDS @ 6" O.C. 1000S162-54 @ 12" O.C. 1 4° WIDE 54 MIL FLAT STRAP @ BOTTOM @ 4' O.C. MEZZANINE JOIST BLOCKING DETAIL SCALE: N.T.S. Party Room Opening Framing Chart Opening Header Jamb Headertolamb 15'WX9'H BOX = (2)60OS200-97 W/ Storefront w/ Door (2)6005200-54 C/1-3.00 (2)6007125-97 &Transom 10'W X 8'H Garage (2)100S162-541oist @Top (2)6005200-54 D&E/1-3.00 Door Opening 60OS162-33 @ El. 8'-0" ROLL -UP GARAGE DOOR BY OTHERS (MAX WEIGHT = 805 LBS); CONNECT BRACKETS SUPPORTING EACH END OF DRIVE ROD TO JAMBS PER MANUFACTURER INSTRUCTIONS, WITH (4) #10SDS MIN. 1 1/8" F.R. PLYWOOD SHEATHING; MAX. NOMINAL WEIGHT = 5 PSF. ==r—I (P10SDS, (� TYP. JOISTS @ 12" O.C.; REFER TO 1/1-3.00 ARCHITECT 4) design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezemclesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 (2)1000S162-54 JOISTS REQUIRED AT GARAGE DOOR JAMBS AS SHOWN. - JAMBS = (2)600S200-54 EA SIDE OF GARAGE DOOR OPENING; CONNECT JAMB STUD PLIES AS SHOWN IN C&E/L3.00. INSTALL ANGLE GUIDE FOR GARAGE DOOR (BY OTHERS) PER MANUFACTURER INSTRUCTIONS. CONNECTION @ JAMB BOT: (1) 6"X2"X2" 54 MIL CFS CLIP ANGLE W/ (4)#10SDS TO JAMB AND (2) 0.157"0 X 1" (4" SPACING) HILTI X -U TO CONC. a REFER TO E/L0.00 FOR INFILL FRAMING @ 9'-0". GARAGE DOOR AT HEAD SCALE: N.T.S. ����,•`���11F ER Zq'� , C E NSE•. is g TE 0R NAL ���,,,,• J 0 a w 0 H J a Q O J LL F_ ro a of = O W LL Z_ Z Q O U) T_ OD r ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 PROJECT NUMBER: 2118015 L3.00 1 • xi Y EXISTING 4" SANITARY SEWER LINE. FIELD VERIFY EXACT LOCATION, SIZE ARCHITECT design AND DEPTH OF EXISTING LINE PRIOR TO CONSTRUCTION. \` i 2• CONNECT NEW 1 1/2" CW LINES TO EXISTING WATER LINES. FIELD VERIFY LOCATION AND SUFFICIENT SIZE DOMESTIC COLD WATER PIPING 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 g PRIOR TO CONSTRUCTION. PHONE: (781) 452-7121 81)875 Www : (pt>��3 om 3 PLUMBING FIXTURES TO EXISTING WASTE LINE. FIELD CONNECT NEW PL VERIFY EXACT LOCATION AND SUFFICIENT SIZE PRIOR TO CONSTRUCTION. 4. ROUTE 1/2' HW & CW LINES TO RESTROOM LAVATORY FAUCET. INSTALL SUPPLIES COMPUTE WITH HOT WATER TEMPERING VALVE. ICLIENT a ? I = € _ a ( JUMP 2018 LLC 5• » TRAP PRIMER WITH 1 /2 CW BELOW FLOOR, FROM TRAP PRIMER TO RECEPTOR. 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 I I p € ! 6. CONNECT NEW 3" VENT UNE TO EXISTING VTR. FIELD COORDINATE EXACT LOCATION OF THE VTR'S. 7• ROUTE 1/2" HW & CW LINES DOWN IN WALL AND CONNECT TO KITCHEN SINK. ELECTRICAL ENGINEER I 8• ROUTE 1/2" CW LINE DOWN WALL TO REFRIGERATOR. — # I F � S �4� . 9• EXTEND 1/2" CW LINE DOWN WALL TO EWC. 10• CONNECT TO EXISTING 3/4" HW LINE. FIELD VERIFY EXACT SIZE & LOCATION OF EXISTING HW UNE. 11 # � � g I; � 1 � ( €� ,t • ROUTE 1/2" COLD WATER LINE DOWN TO WATER CLOSET. 12. EXISTING DOMESTIC COLD WATER. FIELD VERIFY EXACT LOCATION PRIOR i 5 re ! # I 'r r. — ; € i i TO CONSTRUCTION. DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. 13• ROUTE 3/4 CW LINE TO URINAL. lim BLDG. 1I suITE 1420 14. "ICEE" j( € j ' `, t ROUTE 1/2" CW UNE TO MACHINE. WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 15. EXISTING PLUMBING FIXTURE TO REMAIN. # £ a € I3 a, 16. NEW GREASE TRAP UNDER SINK IN PARTY PREP ROOM TO DISCHARGE WITH 1" AIR GAP. FLORIDA ENGINEER NO. 0051096 (MECH) a 3 INTO A FLOOR SINK MECHANICAL & PLUMBING ENGINEER IDSTUDIO4 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 L-2 t i STRUCTURAL ENGINEER 4 ! ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE € € 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 € t I it # I ; ) 4 i£ a — £ J i t I , Z qF t I t I € ii NEW 'ICEE' MACHINE. PROVIDED BY TENANT. 1 I t a ; 7 I € EXTEND NEW 1/2" CW LINE I I FROM CLOSEST COLD WATER Z o MAIN ?° ��� �� I I _��_� I ` i � I { ( J LL a F- - ! r--------------- r --------------- I -------- -, II '��' = O W `s,2 ✓ E j E u - z z "` t ' O All I W co `) f-7 , 01 666 iii � I[ 0- -------- ------------ -� -------------------- SEE ENLARGED PLANS SEE OVERALL PLUMBING PLAN 3/32"=l' -O" 14 I 1/2" V E WH I ( € REVISIONS RRE DESCRIPTION COMMENTS t 1� EMS 15 E FCO M 15 I ikl I � a SEAL g0. �� ��� !�---�—�'t J5 (E)CW — i — I (E)CW — (E)HW 8 KS -1 7—'' I f P (E)4"VTR 15 < KS -1 I a I WC -1 LAV_ 1 ' 6_ �_� I C-1 E FD- - -�-�- _ ISSUED FOR: PERMIT -BID V-1 JAS I ISSUED DATE: 04.04.2018 DRAWN BY: I I jjj -1 # �� _ IAC 2 € EWC 1 I £ I E (E)SAN-(E)SAN LAV -1 FD -1 — 3 - (E)SAN- -�O CHECKED BY: -- PROJECT NUMBER: 2118015 I11 13 I _ g 7 I 0 O 0 I! w 1 ®®�__ TYP UR -1 UR -1 — ®— ! WC_1 C-1 4 4 O O I _ " 3 ! 3 0i —1 WC -1 # — 3 UR -1 _ 3 �-�- �- lel 3 Copyright (c) by Press Zero Design Corp All Rights Reseived. DRAWING NAME I � C31 I I 1 LuFD-1 15 a � 16s>� (E)FD-1 15 1 ��O I PLUMBING Ks -1 — — — i 1 I KS_ 1 I 1 ter` i I PLANS ; a t i. £ DRAWING NO. i £ I Pi 01 ENLARGE PLUMBING WATER PLAN 3 ENLARGE PLUMBING DWV PLAN 2 /1 rZ, I EF � I� yam/ V / � a 2 I I ll I ) >> � I a� a � / iE)3 / / •1 i �2 i/ o 3� 3 ) ( E 3/ R t E I ft , � A ,t P� 1 - � a COLDR PI I/0O TSP) a �1 I a i > 3/�a I a � I 1/2 2a 1 / GREASE INTERCEPTOR DETAIL I 2 SCALE: NONE FINISHED FLOOR r $ , CLEANOUT PLUG AND ---- / BODY. SEE SPECS COVER 4 < ADJUSTING COLLAR 1/8 BEND FULL SIZE, 4 MAX. (TYP) WASTE, VENT Ft WATER RISER DIAGRAMS I SCALE: NONE INSTALL PER PDI STANDARDS & MANUFACTURER'S INSTRUCTIONS. PROVIDE A WHA AT ALL QUICK CLOSING VALVES. AIR CHAMBER (TYP) HOT OR COLD ♦ WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN 20' PROVIDE ONE WHA AT END OF LINE IF BRANCH IS GREATER THAN 20', PROVIDE ANOTHER WHA IN MIDDLE, EACH SIZED FOR HALF THE FIXTURE UNITS J PDI PIPE FIXTURE COLD SIZE SIZE UNIT LOAD UJI A 1/2" 1-11 uj B 3/4" 12-32 C 1" 33-60 LAVATORY/SINK 1.5 D 1-1/4" 61-113 05, z E 1-1/2" 114-154 2 F 2" 154-330 IF HORIZONTAL BRANCH IS LESS THAN 20' PROVIDE ONE WHA AT END OF LINE IF BRANCH IS GREATER THAN 20', PROVIDE ANOTHER WHA IN MIDDLE, EACH SIZED FOR HALF THE FIXTURE UNITS J s 4 FIXTURE UNIT TABULATION ROUGH -IN -SIZE FIXTURE COLD HOT r L VALVE WATER CLOSET 10uj -- -- TANK WATER CLOSET 5 -- S/W URINAL 5 -- WH -1 LAVATORY/SINK 1.5 1.5 3/4" JANITOR'S SINK 3 3 �� [SHOWER/BATHTUB 2 2 s 4 R t Egg ROUGH -IN -SIZE a v:.. - ♦ ��� ,.. .�. MARK FIXTURE r L DESCRIPTION/REMARKS Y b $ � - - V - - -- - MARK FIXTURE S/W V CW HW WH -1 ELECTRIC - - 3/4" 3/4- /4HEATING AO SMITH #DEL -20, 20 GALLON TANK TYPE ELECTRIC WATER HEATER, (1) ELEMENTS, 3000 WATT AMERICAN STANDARD 'CADET' #2835.128, FLOWISE, WHITE VITREOUS CHINA, FLOOR MOUNTED, ADA �� WATER CLOSET 4„ 2" 1/2" _ COMPLIANT TANK TYPE PRESSURE ASSISTED 1.28 GPF WATER CLOSET. TRIP LEVER SHALL BE WATER HAMMER (ADA) TYPE 'M' COPPER WITH 95/5 SILVER SOLDER JOINT FITTINGS. INSULATE CONDENSATE PIPING WITH 1/2" ARMAFLEX LINE PIPE AND INDIRECT PPP, INC. SERIES SC, FULLY MECHANICAL WATER HAMMER ARRESTER SIZED AND LOCATED PER INSTALLED ON WIDE SIDE OF STALL. INCLUDE BEMIS #1055 WHITE ELONGATED OPEN FRONT ARRESTER GAS, NATURAL OR PROPANE _ SIZED _ THE MANUFACTURER SPECIFICATIONS. SEAT -LESS COVER, WITH CHECK HINGE STOPS. EXPANSION WATER CLOSETAMERICAN _ 3/4" _ WATTS REGULATOR DETA-5, WITH STEEL BODY AND BUTYL RUBBER DIAPHRAGM FOR 3.5 GALLONS STANDARD 'CADET' #2835.128, FLOWISE, WHITE VITREOUS CHINA, FLOOR MOUNTED, ADA WC -2 (ADA) 4" 2" 1/2" - COMPLIANT TANK TYPE PRESSURE ASSISTED 1.28 GPF WATER CLOSET. TRIP LEVER SHALL BE MIXING SHUT-OFF VALVE NO 1/2" 1/2" REGULATORG 'NG WITH BRASS BODY AND LFMMV UNDER IRESISTANTOENCL INTEGRAL INSTALLED ON WIDE SIDE OF STALL. INCLUDE BEMIS #1055 WHITE ELONGATED OPEN FRONT VALVE i C.V. CHECK VALVE 13. M UNTINHOLES, TAMPER SURESTATIC VALVE, SEAT -LESS COVER, WITH CHECK HINGE STOPS. -III-- U UNION D� P.V. PPP, INC. ;SPR -500 "PRIME RITE" TRAP PRIMER, BRONZE CONSTRUCTION WITH VACUUM PORTS, AMERICAN STANDARD #0356.028 WALL HUNG WHITE VITREOUS CHINA LAVATORY WITH OVERFLOW, SOC LAVATORYTHREE EAAV EARTHQUAKE ACTUATED AUTOMATIC VALVE (GAS) ADJUSTABLE WITH 1/2" COPPER TYPE "L" TO RECEPTOR. PROVIDE DISTRIBUTION UNIT AS HOLE WITH #6500.174 WIDESPREAD FAUCET, BRASS BODY WITH POLISHED CHROME FINISH, LAV -1 (ADA) - 1 1/2- 1/2' 1/2- .35 GPM AREATOR. INSTALL COMPLETE WITH OPEN GRID STRAINER, RIGID SUPPLIES, ANGLE STOPS, 16. T P & TEMPERATURE & PRESSURE RELIEF VALVE u ® VTR 12" AFF, PROVIDE ACCESS PANEL. AND CHROME PLATED 17 GA L.A. PATTERN CAST BRASS P -TRAP WITH SECURED ESCUTCHEON. AND HD HUB DRAIN ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE AND LOCATED AS FD FLOOR DRAIN (COORDINATE GRATE REQS) P -TRAP SHALL BE WRAPPED WITH TRUEBRO LAVGUARD #100 FOR ADA PROTECTION. FLOOR SINK (COORDINATE GRATE REQS) ALL PLUMBING FIXTURE VENTS TO TERMINATE A MINIMUM OF 12 INCHES FROM ANY RP RECIRCULATION PUMP -�{ I HB STANDARD #6590.005 WITH SLOAN "ROYAL" 186.05 FLUSH VALVE. LOW WATER USE UR -1 URINALAMERICAN (ADA) 2" 1 1/2" 3/4" - VITREOUS CHINA WALL HUNG, SIPHON JET ACTION WITH 3/4" TOP INLET SPUD. PROVIDE WITH MBH BTUH X 1000 CFH CUBIC FEET PER HOUR (1 MBH = 1 CFH) PROVIDE ACCESSIBLE WATER SUPPLY STOP VALVE(S) AT EACH FIXTURE. FLUSHING RIM, THREADED OUTLET AND OPEN TRAY WAY WITH VISIBLE WATER SURFACE. FURNISH EXISTING I.E. INVERT ELEVATION ALL UNDERGROUND METALLIC PIPE AND FITTINGS SHALL BE PROTECTED IN CONN COMPLETE WITH DIAPHRAGM ACTION FLUSH & CHAIR CARRIER. FCO FLOOR CLEANOUT UNE _ _ _ ZURN #1400 ADJUSTABLE FLOOR CLEANOUT, DURA -COATED CAST IRON BODY, GAS AND WATER GPH GALLONS PER HOUR SIZED HP HORSEPOWER TIGHT TAPERED THREAD PLUG, AND 5"0 ROUND POLISHED NICKEL BRONZE TOP. POUNDS PER SQUARE INCH UTILITY CONTRACTOR/ REPRESENTATIVE. LINE ACCESS PANEL W/ ZURN 11443 SQUARE WALL CLEANOUT, DURA -COATED CAST IRON BODY, GAS AND WATER TIGHT WCO WALL CLEANOUT SIZED - - TAPERED THREAD PLUG, AND NICKEL BRONZE SECURED SQUARE, SMOOTH WALL ACCESS COVER ABN ABOVE 30. (E) EXISTING MATERIALS, RODS AND CLAMPS AS REQUIRED FOR COORDINATION WITH WORK OF AND FRAME. UNDERGROUND 31. DN DOWN BE COORDINATED WITH THE BUILDING STRUCTURE AND THE WORK OF OTHER CONT. #LRADQ291855, LUSTERTONE STAINLESS STEEL, #18 GAUGE, EQUAL DOUBLE BOWL, TOP KS -1 KITCHEN SINKELKAY (ADA) 2" 1 1/2" 1/2" 1/2" MOUNT ADA SINK, CENTER DRAIN PLACEMENT WITH ELKAY #LK5000, SINGLE HOLE DECK MOUNT BOH BACK OF HOUSE WHENEVER FOUNDATION WALLS, EXTERIOR WALLS, ROOFS, ETC. ARE PENETRATED FOR A.D.A. AMERICAN DISABILITIES ACT FAUCET WITH PULL-OUT SPRAY, LEVER HANDLE 1.5 GPM. FS -1 FLOOR SINK 3" 2" _ - ZURN #FD -2370 12"02" RADIUSED PVC BODY FLOOR SINK WITH FULL RIM AND SEDIMENT CHANGES MADE IN THE PLUMBING SYSTEMS. THE RECORD DRAWING SHALL SHOW CHANGES IN MANUFACTURER (WITH NUMBERS AND TRADE NAMES). MATERIALS, SIZES, LOCATIONS AND HOOK-UP POINTS. AS-BUILTS SHALL BE GIVEN TO OWNER'S BUCKET STRAINER. COORDINATE GRATE CONFIGURATION WITH KITCHEN ROUGH IN PLANS. ED -1 FLOOR DRAIN 2" 1 1/2" 1/2" - ZURN #LC-P3S PVC BODY FLOOR DRAIN AND TRAP PRIMER, WITH ;SLC -CS CAST IRON ADAPTOR THOSE REQUIRED BY LAW. 37. PLUMBING CONTRACTOR SHALL BE ON SITE AND PRESENT AT THE DATE OF STORE TURNOVER. 38• THREADED SHANK, COMPLETE WITH #LC-FR05NI 5" ROUND POLISHED NICKEL FRAME TOP GRATE. ELECTRIC- ELKAY #LZSTL8WSSP, EZH2O BOTTLE FILLER STATION, BI -LEVEL BARRIER -FREE, STAINLESS EWC-1 WATER COOLER 2" 1 1/2" 1/2" STEEL POLISHED TO A SATIN FINISH, SOFT SIDES WATER COOLER, FLEXI-GUARD SAFETY BUBBLER, QUICK FILL RATE 1.1 GPM. GREASEENDURA #391OA02, 10 GPM GREASE INTERCEPTOR, SMALL FOOTPRINT, BAFFLE SYSTEM TO ENHANCE GI -1 INTERCEPTOR 2" 2" - - SEPARATION PERFORMANCE AT LOW FLOW AND EZ -CLEAN EXTERIOR TANK. 14.5007.5"06.3". s 4 R t Egg { z a✓ h �5. a v:.. - ♦ ��� ,.. .�. Y` }` � -s.., . ,- - 3 ...... "^'!ia a :.. a•_--. ... /?. .s+, D j .. ns.., .., .,.... Hr.«,>.. >4 .. ..a.. �. -v. ,�: %F ,., .._.:'L _ 3<v.`u, ,_t.'a" x-. '" ..+, "avr ,.,i ,r.. ,t x�`A.. w .. . .... � k.`,i..r- -.:., ':t «., ... ,. k - r L GW Y b $ � - - V - - ROUGH -IN -SIZE VENT MARK FIXTURE DESCRIPTION/REMARKS ST S/W V CW HW WITH A CELL CLASS OF 24448 AS IDENTIFIED IN ASTM D 1784. WH -1 ELECTRIC - - 3/4" 3/4- /4HEATING AO SMITH #DEL -20, 20 GALLON TANK TYPE ELECTRIC WATER HEATER, (1) ELEMENTS, 3000 WATT SEWER AND VENT PIPE WATER HEATER FSW (ABOVE AND BELOW (HUBLESS) CAST IRON SOIL PIPE AND STAINLESS STEEL NO HUB COUPLINGS. HW ELEMENT AT 480 VOLT, SET AT 110'F. 15 GPH RECOVERY CAPACITIES 0 90' RISE WHA -1 WATER HAMMER _ TYPE 'M' COPPER WITH 95/5 SILVER SOLDER JOINT FITTINGS. INSULATE CONDENSATE PIPING WITH 1/2" ARMAFLEX LINE PIPE AND INDIRECT PPP, INC. SERIES SC, FULLY MECHANICAL WATER HAMMER ARRESTER SIZED AND LOCATED PER G ARRESTER GAS, NATURAL OR PROPANE _ SIZED _ THE MANUFACTURER SPECIFICATIONS. DN. EXPANSION _ _ 3/4" _ WATTS REGULATOR DETA-5, WITH STEEL BODY AND BUTYL RUBBER DIAPHRAGM FOR 3.5 GALLONS FLOOR CLEANOUT TANK DCO DOUBLE CLEANOUT I CO CAPACITY/ 2.1 GALLONS ACCEPTANCE, 40 PSI FACTORY PRE -CHARGED. MXV-1 MIXING SHUT-OFF VALVE NO 1/2" 1/2" REGULATORG 'NG WITH BRASS BODY AND LFMMV UNDER IRESISTANTOENCL INTEGRAL SOV VALVE i C.V. CHECK VALVE 13. M UNTINHOLES, TAMPER SURESTATIC VALVE, BALANCING VALVE -III-- U UNION D� P.V. PPP, INC. ;SPR -500 "PRIME RITE" TRAP PRIMER, BRONZE CONSTRUCTION WITH VACUUM PORTS, SEALS SHALL BE INSTALLED BY THE ROOFING CONTRACTOR. ENSURE THAT AMPLE SOC SHUT-OFF COCK (GAS) EAAV EARTHQUAKE ACTUATED AUTOMATIC VALVE (GAS) ADJUSTABLE WITH 1/2" COPPER TYPE "L" TO RECEPTOR. PROVIDE DISTRIBUTION UNIT AS TP -1 TRAP PRIMER - - 1/2" _ REQUIRED FOR SUPPLY TO MULTIPLE DRAINS. INSTALL VALVE RECESSED IN WALL A MINIMUM POINT OF CONNECTION 16. T P & TEMPERATURE & PRESSURE RELIEF VALVE u ® VTR 12" AFF, PROVIDE ACCESS PANEL. NOTE: FOR BATTERIES OF FIXTURES, PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON & 0 -RING CONSTRUCTION, HAVING PDI #WH -201, ASSE #1010 & ANSI #A112.26.1 M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND/OR PER THE TABLES SHOWN ABOVE. PROVIDE ACCESSIBILITY WHERE REQUIRED BY LOCAL CODE. WATER HAMMER ARRESTOR DETAIL I 3 SCALE: NONE -RISER (LENGTH AS REQUIRED) 45' WYE PLUG IF END FITTING (TYP) OF LINE (TYP) FLOW CLEANOUT DETAILS 4 SCALE: NONE SYMBOL k { z a✓ h �5. SAN e r� x £ .a r L GW Y b $ � - - V - - V VENT 1 • WATER PIPE (ABOVE FLOW GUARD CTS CPVC PIPE AND FITTINGS SHALL BE MANUFACTURED FROM VIRGIN RIGID CPVC VINYL COMPOUNDS ST GROUND) WITH A CELL CLASS OF 24448 AS IDENTIFIED IN ASTM D 1784. 2• WATER PIPE (BELOW SIMILAR MATERIAL TO ABOVE GROUND PIPING. NO JOINTS OR UNIONS SHALL BE INSTALLED BELOW THE BUILDING SLAB. FW GROUND) FILTERED WATER 3. SEWER AND VENT PIPE BELOW AND ABOVE GRADE DWV SCHEDULE 40 POLYVINYL CHLORIDE (PVC) PIPING. INSIDE BUILDING SERVICE WEIGHT FSW (ABOVE AND BELOW (HUBLESS) CAST IRON SOIL PIPE AND STAINLESS STEEL NO HUB COUPLINGS. HW GRADE) HOT WATER 4. CONDENSATE DRAIN TYPE 'M' COPPER WITH 95/5 SILVER SOLDER JOINT FITTINGS. INSULATE CONDENSATE PIPING WITH 1/2" ARMAFLEX RCL PIPE AND INDIRECT CLOSED CELL PIPE INSULATION WITH SELF SEALING ADHESIVE JOINTS, OR EQUIVALENT. G DRAINAGE PIPE GAS, NATURAL OR PROPANE 0 (INTERIOR TO BUILDING) PIPE UP SYMBOL ABBREV. DESCRIPTION SAN S OR W SOIL OR WASTE (BELOW GRADE) - -GW- - GW GREASE WASTE - - V - - V VENT CD CD CONDENSATE DRAIN ST ST STORM DRAIN CW CW COLD WATER FW FW FILTERED WATER SW SW SOFTENED WATER FSW FSW FIRE SERVICE WATER HW HW HOT WATER HWR HWR HOT WATER RETURN RCL RCL RECLAIMED HEAT WATER G G GAS, NATURAL OR PROPANE 0 UP PIPE UP ANY DEVIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHALL BE BROUGHT TO DN. TEE DOWN C DN. PIPE DOWN �--- FCO FLOOR CLEANOUT low DCO DOUBLE CLEANOUT I CO CLEANOUT, WALL OR PIPE SOV SHUT-OFF VALVE NO SOV SHUT-OFF VALVE, NORMALLY OPEN NC SOV SHUT-OFF VALVE, NORMALLY CLOSED i C.V. CHECK VALVE 13. B.V. BALANCING VALVE -III-- U UNION D� P.V. MECHANICAL PLUG VALVE (GAS) SEALS SHALL BE INSTALLED BY THE ROOFING CONTRACTOR. ENSURE THAT AMPLE SOC SHUT-OFF COCK (GAS) EAAV EARTHQUAKE ACTUATED AUTOMATIC VALVE (GAS) ALL WATER PIPING TO BE INSULATED AS PER THE INTERNATIONAL PLUMBING CODE S.V. ELECTRIC SOLENOID VALVE (GAS) R P.R. PRESSURE REGULATOR (GAS) di POC POINT OF CONNECTION 16. T P & TEMPERATURE & PRESSURE RELIEF VALVE u ® VTR VENT TO ROOF ® HD HUB DRAIN ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE AND LOCATED AS FD FLOOR DRAIN (COORDINATE GRATE REQS) FS FLOOR SINK (COORDINATE GRATE REQS) ALL PLUMBING FIXTURE VENTS TO TERMINATE A MINIMUM OF 12 INCHES FROM ANY RP RECIRCULATION PUMP -�{ I HB HOSE BIBB ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS CONNECTED SUPPLY LINE UNLESS KEC KITCHEN EQUIPMENT CONTRACTOR 20. BTUH BRITISH THERMAL UNITS PER HOUR PRIOR TO EQUIPMENT CONNECTIONS. MBH BTUH X 1000 CFH CUBIC FEET PER HOUR (1 MBH = 1 CFH) PROVIDE ACCESSIBLE WATER SUPPLY STOP VALVE(S) AT EACH FIXTURE. (E) EXISTING I.E. INVERT ELEVATION ALL UNDERGROUND METALLIC PIPE AND FITTINGS SHALL BE PROTECTED IN CONN CONNECTION FU FIXTURE UNITS CONCRETE FOOTINGS. GPM GALLONS PER MINUTE GPH GALLONS PER HOUR START OF WORK. HP HORSEPOWER PSI POUNDS PER SQUARE INCH UTILITY CONTRACTOR/ REPRESENTATIVE. AP ACCESS PANEL W/ WITH FLOOR TO PROVIDE CLEARANCE FOR CLEANING. FLR FLOOR CLG CEILING SHALL UTILIZE CORE DRILLING EQUIPMENT. COORDINATE WITH ARCHITECTURAL ABN ABOVE 30. (E) EXISTING MATERIALS, RODS AND CLAMPS AS REQUIRED FOR COORDINATION WITH WORK OF UG UNDERGROUND 31. DN DOWN BE COORDINATED WITH THE BUILDING STRUCTURE AND THE WORK OF OTHER CONT. CONTINUE TYP. TYPICAL NO LIQUID TRANSMISSION PLUMBING PIPING SHALL BE INSTALLED ABOVE ELECTRICAL FOH FRONT OF HOUSE BOH BACK OF HOUSE WHENEVER FOUNDATION WALLS, EXTERIOR WALLS, ROOFS, ETC. ARE PENETRATED FOR A.D.A. AMERICAN DISABILITIES ACT A.F.F. ABOVE FINISH FLOOR EXPOSED PIPING IN THE GUEST AREAS SHALL BE PAINTED TO MATCH THE WALL B.F.F. BELOW FINISH FLOOR �- v £ f ` ' N". 3 � � k as .`, � •�Y-�' 1, ks�'�s,' an�. ,k.. _. t fir 5 sl k $ ,�".� �N$'�r" � � ��`�� '�.. 1. TEST INSTALLED WATER PIPING AT 100 PSI FOR A PERIOD OF 8 HOURS, OBSERVING FOR ANY VISIBLE LEAKS. TEST PIPING AGAIN WITH FIXTURES INSTALLED. 2. CHLORINATE ALL WATER PIPING FOR A PERIOD OF 8 HRS, BY CHARGING WITH A OF ALL DATA IN ALL OF THE CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION HYPOCHLORINATE SOLU11ON TO ACHIEVE A 5 PPM STRENGTH AT THE FIXTURE 2. FURTHEST FROM THE POINT OF APPLICATION. UPON COMPLETION OF THE CHLORINATION, FLUSH ALL PIPING UNTIL NO CHLORINE CAN BE DETECTED BY 3. TASTE. CLEAN ALL STRAINERS AND SET WATER FLOWS FROM FIXTURES IN ACCORDANCE WITH MANUFACTURER AND LOCAL REQUIREMENTS. 3. TEST INSTALLED GAS PIPING AT 60 PSI FOR A PERIOD OF 2 HRS, USING SOAP AND WATER OBSERVING FOR ANY VISIBLE LEAKS AT ALL JOINTS. 4. TEST INSTALLED WASTE AND VENT PIPING FOR A PERIOD OF 8 HRS, BY CAPPING 5. OR PLUGGING ALL JOINTS TO A LEVEL OF THE HIGHEST FIXTURE OR FITTING. FILL J LL THE SYSTEM WITH WATER AND OBSERVE FOR ANY LEAKS. ARCHITECT ro x .. design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 WWWpliasezarcidesignmci t1 CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 r 1. NOTE: FOR THE PURPOSE OF CLEARNESS AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZES AND LOCATIONS OF EQUIPMENT ARE DRAWN TO SCALE WHEREVER POSSIBLE, THE CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL OF THE CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION PRIOR TO ORDERING, FABRICATING OR INSTALLING ANY MATERIALS. 2. THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL CONFORM TO ALL FEDERAL, STATE AND LOCAL CODES AND AUTHORITIES HAVING JURISDICTION. 3. PLUMBING QUALITY, WEIGHTS OF MATERIALS AND ALTERNATE METHODS OF CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL PLUMBING CODE 4. CONTRACTOR SHALL COORDINATE ALL WORK SHOWN ON THESE DRAWINGS AND SPECIFICATIONS WITH ALL DISCIPLINES AND TRADES PRIOR TO SUBMITTAL OF BID AND INSTALLATION OF SYSTEM. 5. CONTRACTOR SHALL MAKE ALL ARRANGEMENTS WITH UTILITY COMPANIES FOR J LL SERVICE AND CONNECTIONS AND SHALL PAY FOR ALL FEES, CHARGES, PERMITS AND METERS. 6. THE PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND LABOR (INCLUDING THE COMPLETE PLUMBING SYSTEM) FOR A PERIOD OF ONE YEAR FROM =O W WRITTEN ACCEPTANCE BY THE TENANT. ANY DEFECTS IN MATERIALS AND OR LABOR FOUND WITHIN THE GUARANTEE PERIOD SHALL BE REMEDIED OR REPAIRED BY THIS Z Q 0 CONTRACTOR IN A TIMELY FASHION, AT NO COST TO THE TENANT. 7• ALL PLUMBING FIXTURE LOCATIONS (WATER CLOSETS, LAVATORIES ETC.) ARE DIAGRAMMATIC. CONTRACTOR SHALL. REFER TO FOOD SERVICE AND ARCHITECTURAL o DRAWINGS FOR EXACT PLACEMENT AND MOUNTING HEIGHTS. 8. ANY DEVIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. 9. CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTAL OF BID AND FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS. SUBMITTAL OF BID WILL VERIFY THAT THE CONTRACTOR HAS VISITED THE SITE. 10. PIPING SHALL BE INSTALLED PARALLEL TO BUILDING LINES AND SUPPORTED AND ANCHORED AS REQUIRED TO FACILITATE EXPANSION AND CONTRACTION. THE INSTALLATION SHALL MEET ALL CONSTRUCTION CONDITIONS AND ALLOW FOR THE INSTALLATION OF OTHER TRADES. 11 • SUPPORT PIPING WITH CLEVIS OR SPLIT RING TYPE PIPE HANGERS WITH 3/8" ALL THREAD ROD AND BEAM CLAMPS. "PLUMBERS TAPE AND WIRE" NOT PERMITTED. 12. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON -ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL. 13. ALL SERVICE WATER HEATING EQUIPMENT TO BE IN COMPLIANCE WITH THE INTERNATIONAL PLUMBING CODE REQUIREMENTS. 14. ALL ITEMS PROJECTING THROUGH THE ROOF SHALL BE FLASHED THROUGH CURBS OR PIPE SEALS A MINIMUM OF 12" ABOVE THE ROOF. THE PIPE CURBS AND SEALS SHALL BE INSTALLED BY THE ROOFING CONTRACTOR. ENSURE THAT AMPLE BOOT OPENINGS ARE PROVIDED TO ACCOMMODATE ANY ELECTRICAL CONDUIT PENETRATIONS REQUIRED FOR POWER. 15. ALL WATER PIPING TO BE INSULATED AS PER THE INTERNATIONAL PLUMBING CODE REQUIREMENTS: PIPE SIZEINSULATION THICKNESS INSULATION VALUE 1M R= 4.0 1 2N THRU 1 1/4- 1-1/2" THRU 2"1 1/2" R = 6.0 16. CONTRACTOR SHALL PROVIDE: FAUCETS, TRAPS, STOPS, BALL VALVES, BACKFLOW DEVICES FOR KITCHEN EQUIP. GASCOCKS, WATER HAMMER ARRESTORS, CLEANOUT COVERS AND INDIRECT WASTE TO AN APPROVED RECEPTOR AND ALL NECESSARY TRIM FOR A COMPLETELY CONNECTED PLUMBING SYSTEM. 17. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE AND LOCATED AS PER CODE REQUIREMENTS. THE CONTRACTOR SHALL COORDINATE ALL CLEAN OUT LOCATIONS WITH EQUIPMENT, MILLWORK, ETC., PRIOR TO INSTALLATION. 18. ALL PLUMBING FIXTURE VENTS TO TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACE AND 10'-0" FROM OR 3'-0" ABOVE ANY MECHANICAL EQUIPMENT OUTSIDE AIR INTAKE. 19. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS CONNECTED SUPPLY LINE UNLESS OTHERWISE NOTED ON DRAWINGS. 20. UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH SCREW-TYPE VALVE AND PRIOR TO EQUIPMENT CONNECTIONS. 21. PIPING SHALL BE INSTALLED COMPLETE WITH DIELECTRIC UNIONS BETWEEN CONNECTIONS OF NON-FERROUS MATERIALS. 22• PROVIDE ACCESSIBLE WATER SUPPLY STOP VALVE(S) AT EACH FIXTURE. 23. PROVIDE A LINE SIZED PRESSURE REDUCING VALVE AT THE BUILDING SERVICE CONNECTION SHOULD THE SUPPLY PRESSURE EXCEED 80 PSI. 24. ALL UNDERGROUND METALLIC PIPE AND FITTINGS SHALL BE PROTECTED IN ACCORDANCE WITH THE SOILS ENGINEER'S RECOMMENDATIONS. PIPING SHALL BE DIR T Y M DDD IN CONCRETE MASONRY WALLS OR 0 ECL E BE E CONCRETE FOOTINGS. 26. THE PLUMBING CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR ALL POINTS OF CONNECTION WITH THE GENERAL CONTRACTOR AND OTHER TRADES PRIOR TO START OF WORK. 27. VERIFY EXACT LOCATIONS, DEPTH AND SIZE OF ALL PIPING TO WHICH CONNECTIONS ARE REQUIRED. COORDINATE ALL CONNECTIONS WITH SITE CONDITIONS AND SITE UTILITY CONTRACTOR/ REPRESENTATIVE. 28. ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATIONS AND NOT LESS THAN 6" ABOVE THE FLOOR TO PROVIDE CLEARANCE FOR CLEANING. 29• ALL CUTTING OF EXISTING PAVING, WALKS AND/OR FLOORS SHALL UTILIZE MACHINE SAW CUTTING EQUIPMENT. HOLES FOR PIPES IN CONCRETE WALLS OR FLOORS SHALL UTILIZE CORE DRILLING EQUIPMENT. COORDINATE WITH ARCHITECTURAL DETAILS FOR FLOOR CUTTING AND PATCHING. 30. THE PLUMBING CONTRACTOR IS TO PROVIDE ALL ADDITIONAL STEEL, HANGER MATERIALS, RODS AND CLAMPS AS REQUIRED FOR COORDINATION WITH WORK OF OTHER TRADES. 31. PIPING LAYOUT IS SCHEMATIC ONLY, EXACT ROUTING AND INSTALLATION OF PIPES TO BE COORDINATED WITH THE BUILDING STRUCTURE AND THE WORK OF OTHER CONTRACTORS. NO WATER OR DRAIN LINES ARE PERMITTED TO BE INSTALLED OVER OR UNDER ELECTRICAL PANELS. 32. NO LIQUID TRANSMISSION PLUMBING PIPING SHALL BE INSTALLED ABOVE ELECTRICAL SWITCH GEAR, EQUIPMENT, OR PANELS. MAKE ADJUSTMENTS NECESSARY TO REROUTE PIPING FOR ACTUAL INSTALLATION OF ELECTRIC EQUIPMENT. 33. WHENEVER FOUNDATION WALLS, EXTERIOR WALLS, ROOFS, ETC. ARE PENETRATED FOR THE INSTALLATION OF PLUMBING SYSTEMS, THEY SHALL BE PATCHED TO MATCH EXISTING CONSTRUCTION AND SEALED WEATHER TIGHT. 34. EXPOSED PIPING IN THE GUEST AREAS SHALL BE PAINTED TO MATCH THE WALL COLOR. EXPOSED GAS PIPING IN THE KITCHEN SHALL BE PAINTED WHITE. 35. DURING THE PROGRESS OF THE WORK, MAINTAIN AN ACCURATE RECORD OF ALL CHANGES MADE IN THE PLUMBING SYSTEMS. THE RECORD DRAWING SHALL SHOW CHANGES IN MANUFACTURER (WITH NUMBERS AND TRADE NAMES). MATERIALS, SIZES, LOCATIONS AND HOOK-UP POINTS. AS-BUILTS SHALL BE GIVEN TO OWNER'S CONSTRUCTION MANAGER AT COMPLETION OF JOB. 36. UPON COMPLETION OF JOB, THIS CONTRACTOR SHALL INSPECT ALL EXPOSED PORTIONS OF THE PLUMBING INSTALLATION AND COMPLETELY REMOVE ALL EXPOSED LABELS, SOIL., MARKINGS AND FOREIGN MATERIAL EXCEPT PRODUCT LABELS AND THOSE REQUIRED BY LAW. 37. PLUMBING CONTRACTOR SHALL BE ON SITE AND PRESENT AT THE DATE OF STORE TURNOVER. 38• PLUMBING CONTRACTOR SHALL PROVIDE MANUFACTURER'S OPERATION LITERATURE FOR ALL INSTALLED EQUIPMENT AND FIXTURES AT THE DATE OF STORE TURNOVER. ARCHITECT ro x .. design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 WWWpliasezarcidesignmci t1 CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 I REV I DATE I DESCRIPTION I COMMENTS I SEAL ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: -- CHECKED BY: -- PROJECT NUMBER 2118015 Copyright (c) by Phase Zero Design Corp. All Rights Reserved. DRAWING NAME PLUMBING SCHEDULES & DETAILS DRAWING NO. P201 Ii■ a W O mj 0 J LL s0 Q =O W LL Z w Z Q 0 O W o o J Q I REV I DATE I DESCRIPTION I COMMENTS I SEAL ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: -- CHECKED BY: -- PROJECT NUMBER 2118015 Copyright (c) by Phase Zero Design Corp. All Rights Reserved. DRAWING NAME PLUMBING SCHEDULES & DETAILS DRAWING NO. P201 F_ I / ... 1s I i»» I 1 ;.� i'"�. ` i I [ s r x' ARCHITECT ECT design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www#msez IDdesign.com A. ALL OUTDOOR AIR INTAKES BY MECHANICAL EQUIPMENT SHALL HAVE A MINIMUM 10'-0" HORIZONTAL CLEARANCE FROM THE DISCHARGE OF ANY EXHAUST FAN, COMBUSTION EXHAUST OR PLUMBING VENT. B. PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE DUCT/ PIPING CONNECTIONS TO ALL MOVING MACHINERY NOT INTERNALLY ISOLATED. C. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. I D. THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER LOCATIONS WITH LIGHT FIXTURES AS WELL AS SPRINKLER PIPING AND HEADS (WHERE INCLUDED IN THE PROJECT) FOR A COMPLETE INSTALLATION. CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 I ' ? iX } ' I ' i a a I i I? a �k _.__ .______._.__._.______ _.__ �_».�.____________ _._.__ �' I i ,X � I I ________ __._�__� _ � .____...___ .._ I i 1 I d t kms_ - - ..._ ._.__ -� _ _- 0L0 x° 2 I g a -x � �..._.__- ___._._.______._ ___ ! a I � I x �____ ___ � _____. ____.._� o _ n __ _ _ __ . _ __ ______ _ _ ___ ___ a _^�t I a �_ C I FX = -- - - -i __ __._._ _ _ _ I o�x ( d ::x - _.__� _ __.._ _ _._ 1 , fifi 3I7 I 0L i I A ..».�., a x ; ] �_ E. LOCATIONS FOR THERMOSTATS AND REMOTE SENSORS SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL -MOUNTED DECOR OR PROXIMITY TO HEAT PRODUCING EQUIPMENT. F. ALL HVAC AND RESTROOM EXHAUST DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE UNDER THE ROOF STRUCTURE. ELECTRICAL ENGINEER DON PENN A BLVD.nHc eHatNeeR 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.28581 F 817.251.8411 G. ALL RECTANGULAR, ROUND, AND FLEXIBLE DUCTWORK SHALL BE SIZED AS SHOWN ON THESE DRAWINGS; AND SHALL BE FABRICATED AND INSTALLED ACCORDING TO THE MOST RECENTLY PUBLISHED SMACNA STANDARDS. ALL JOINTS, SEAMS, AND CONNECTIONS MUST BE SECURELY FASTENED & SEALED BY APPROVED METHODS. H. ANY FLEXIBLE DUCTS SHALL BE INSTALLED IN CONCEALED SPACES ONLY. THE MAXIMUM ALLOWABLE LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". ALL FLEXIBLE DUCTS SHALL BE CONNECTED TO BRANCH RUNS AND FITTINGS WITH A PANDUIT-TYPE BAND, AND SHALL NOT BE ATTACHED DIRECTLY TO THE AIR DEVICE COLLAR. I. SUPPLY RETURN RESTROOM EXHAUST DUCT CONSTRUCTION SHALL BE GALVANIZED STEEL. GAUGES, SWAY BRACING AND SUSPENSION SHALL CONFORM TO SMACNA STANDARDS. SEAL ALL SEAMS AND JOINTS AIR AND WATERTIGHT. FLEXIBLE ALUMINUM DUCTWORK OR FIBERGLASS DUCTBOARD IS NOT ALLOWED (UNO). I I I� 1 9 I I r t 10 t (TYP) - I (E)RTU-3 (TYP) II 3 [ (TYP)o t._ <t.. x H ?Ni.. RTU -3 F I - - x x = "s?) - S S $ (E)RTU- 8 I- FX Fx ` E x a =x „C; a x (� 1 (E)RTU-2iK, a Q - - F - --- RTU -2 a I Q ( �_x x I I E_x I _ u { - - � I - I I U t I i i � i `a II - 2 2A FLORIDA ENGINEER NO. 0051096 (MECH) J. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING THE AIR FILTERS AT THE AIR HANDLERS AND ROOFTOP UNITS WITH PLEATED MERV 8 THROW AWAY TYPE AIR FILTERS AT THE COMPLETION OF CONSTRUCTION AND PRIOR TO AIR BALANCE AND STORE TURNOVER. — MECHANICAL s PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING TX 75038 PHONE: (972) 870-1288 AT THE START OF CONSTRUCTION THE MECHANICAL CONTRACTOR SHALL FIELD VERIFY THE VERTICAL CLEARANCE REQUIRED FOR INSTALLATION OF Q EQUIPMENT AND DUCTWORK IN COORDINATION WITH EXISTING CONDITIONS, INCLUDING ROOF STRUCTURE, AND PROVIDE DIRECTION TO THE GENERAL CONTRACTOR FOR FINISHED CEILING HEIGHTS AND ROOF OPENINGS. ANY REQUIRED DEVIATION FROM THE HEIGHTS SHOWN IN THE ARCHITECTURAL CEILING PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND TENANT'S CONSTRUCTION MANAGER. STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 1. EXISTING SUPPLY AND RETURN DROPS TO REMAIN. PROVIDE CONCENTRIC DIFFUSER RUSKIN MODEL CDS-18 (OR SIMILAR.) BOTTOM OF DIFFUSER SHALL BE A MINIMUM OF 19'-0" ABOVE EXISTING SLAB UNLESS NOTED OTHERWISE. CONTACT ENGINEER IMMEDIATELY FOR DIRECTION IF THIS MINIMUM HEIGHT CAN NOT BE MET. 2. EXISTING SUPPLY AND RETURN DROPS TO REMAIN. VERIFY EXISTING SUPPLY AIR DRUM. CLEAN AND PAINT TO MATCH ROOF DECK. ALL NEW AND EXISTING DUCTWORK MUST BE A MINIMUM OF 19'-0" ABOVE EXISTING SLAB UNLESS NOTED OTHERWISE. CONTACT ENGINEER IMMEDIATELY FOR DIRECTION IF THIS MINIMUM HEIGHT CAN NOT BE MET. I I _n_- ----F � I I I I a E. r-� F,. - - I S H qr.^e € :. ...+C 1 (TYP) I S " ,3E INN 10 (nP) i P �Q"} m m x -x%I�_ - - - - S S RTU -4 I I - - v Fri ,._., - ll OF ri ""'E _:`t i.. I ' I Q xx=r��Ex I r cX I GFX - g �- W a.1 Y �.,, EX A I o _ -�--_ r- 71- - - I - - - I ( (E)RTU-1 �- -- - -t - r� - �:�_ F} F_X RTU -1 -'I:3 :Ni_ rY, t - - - ; , 13.4 I I it EX I - ( f i II - I I i I it $ i PI - - ! l 5 (TYP 11) T 1 Ei ' ' ' _._ i Q W Z 0 I� Q O J V- = O W 0 z Z 5E Q U) o T_ W c 3. EXISTING RETURN AIR DROP FROM RTU AND RETURN AIR PLENUM TO REMAIN. COVER RETURN AIR OPENING WITH 1 /4"X 1 /4" WIRE MESH SCREEN AND PAINT BLACK ON THE INSIDE FOR LINE -OF -SIGHT. 4, WALL MOUNTED REMOTE ZONE TEMPERATURE SENSOR SHALL BE MOUNTED AT 72- AFF AND WIRED BACK TO RESPECTIVE PROGRAMMABLE THERMOSTAT BEHIND FRONT DESK. COORDINATE PLACEMENT WITH WALL DECOR AND EQUIPMENT. FIELD VERIFY WITH THE OWNER'S REPRESENTATIVE FOR THE FINAL LOCATION PRIOR TO INSTALLATION. 5. PROGRAMMABLE THERMOSTATS BEHIND FRONT DESK TO BE MOUNTED AT 72" AFF AND VERTICALLY STACKED AND CLEARLY LABELED. VERIFY PLACEMENT WITH ARCHITECTURAL FLOOR PLAN AND INTERIOR ELEVATIONS. 6. TURN DOWN SUPPLY AIR DUCT AND ROUTE BELOW STORAGE PLATFORM. COORDINATE WITH ARCHITECTURAL PLANS AND ELEVATIONS TO AVOID CONFLICTS. PROVIDE OFFSETS AND FITTINGS AS NECESSARY. 7. PROVIDE CEILING MOUNTED EXHAUST GRILLE AND ATTACH TO NEW EXHAUST MAIN. EXTEND THE 12X12 RESTROOM EXHAUST RISER UP TO ROOF MOUNTED EXHAUST FAN. FIELD VERIFY ANY REQUIRED TRANSITIONS OR OFFSETS OF EXHAUST DUCT FROM ROOF. 8. NEW EXPOSED RIGID DUCTWORK SHALL BE COATED WITH PAINT PRIMER FOR FINAL PAINTING BY THE GC. VERIFY EXACT COLOR WITH ARCHITECT. 9. NEW TRANSFER OPENING ABOVE CEILING FOR RETURN AIR PATH. PROVIDE SURFACE MOUNTED GRILLE SIZED AS SHOWN. MOUNT GRILLE AS HIGH ON WALL AS POSSIBLE. 10. EXISTING SMOKE DETECTOR IN SUPPLY AND RETURN DUCTS CAPABLE OF SHUTTING DOWN THE NIT UPON DETECTION OF SMOKE IN THE u AIRSTREAM TO REMAIN. i I I I i i 12X8 DD I [,p�a"��� S RTU -7 [} 24X 10 L✓ - _ - - S {/�nJ�� I I / °'J -/°y� (Dr, - - �J'` yjJ 4 (TYP) ��j 18x6 RTU -9o g - ':..x_x S I::x 250 Ex CR ,4. ` _ 6 I 12X8 f, j x DD I 250 I (TYP 2) I X00 16X14 1ox10 TR r� (E)RTU-1 S f I Em -1 18X6 GE" CR TR 9 (TYP 3) (TYP 3) RTU- 11 F, - — — 24X12 a 9 - H _ B�=� I (TYP 2) _ IPL S I I 6`r X r- 1X1 I 12X12 Lorm L? � „ 10 300 I I _. w a REVISIONS REV DATE DESCRIPTION / COMMENTS o w I 6 w �w 1 I- - _ S7(MTU--Il _ :' -'L E r EG 7 7 75 CD SEAL 50 1/1 6"0 CD 150 (TYP 6) 10"o CD 300 (TYP 2) 10"o 8„0 EG CD 300 7 200 (TYP 2) (TYP 2) ( f MECHANICAL PLAN - GROUND FLOOR 1/8"=V-0” ISSUED FOR: PERMIT - BID 16X14 18X6 18X6 ISSUED DATE: 04.04.2018 DRAWN BY: - I• _ _ I TR 9 I TR 9 I I CHECKED BY: — PROJECT NUMBER: 2118015 (E)RTU-10 12X10 10X10 CopyrpM (c) by Phase Zero Design Corp. AN Rph„ Reserved. DRAWING NAME 0 0 x I I 12x6 � �...z1�I I - 3 1 I DD 200 (TYP 3) I MECHANICAL PLAN � 1 j DRAWING NO. M 101. � _ MECHANICAL PLAN MEZZANINE 1/8"=1'41 2 MARK PICTURE FACE SIZE TYPE MOUNTING TYPE MAXIMUM N.C. DIRECTION MANUFACTURER MODEL NOTES JUMP AREA RTU -3 THRU 7 200 0.0 SERVING 0 19857 0.30 5957 SEATING AREA/PARTY ROOMS RTU -4,6 i 0.0 OFFICE RR 0 5608 0.30 1682 FRONT ENTRY RTU -1 CD w 24X24 SUPPLY LAY -IN 30 4 -WAY TITUS OMNI 1,3,4 5.0 Y,. 15 176 0.06 11 LCA060H LCA060H LCA060H LCA048H LCA060H LCA060H z TYPE ELECTRIC SUBTOTALS ELECTRIC ELECTRIC ELECTRIC ELECTRIC 55 ELECTRIC ELECTRIC 7774 ELECTRIC CUBIC FEET PER MINUTE DOUBLE TOTAL 0/A REQUIRED - - DD CFM SEE PLAN SUPPLY SURFACE 30 DEFLECTION TITUS 30OFS 1,3,5 EG - 24X24 EXHAUST LAY -IN 30 1 -WAY TITUS 355FL 1,3,6 TR 12. SEE PLAN RETURN SURFACE 30 1 -WAY TITUS 355FL 1,3 CR - 24X24 RETURN LAY -IN 30 1 -WAY TITUS 8F 1,3 NOTES: (NOT ALL MAY APPLY) 1. PROVIDE NECESSARY MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED FOR INTENDED INSTALLATION. 2. AIR DEVICE(S) SHALL HAVE MANUFACTURER APPLIED PRIMER FINISH SUITABLE FOR FINAL PAINT FINISH (BY OTHERS). REFER TO THE ARCHITECTURAL DRAWINGS FOR COORDINATION. 3. AIR DEVICE(S) SHALL BE FACTORY FINISHED WHITE. 4. AIR DEVICE(S) SHALL BE INSTALLED WITH MANUFACTURER AVAILABLE MOLDED INSULATION BACKING. FIELD FABRICATED INSULATION BACKING IS NOT ALLOWED (UNLESS FIRST APPROVED BY THE OWNER'S CONSTRUCTION MANAGER). 5. PROVIDE FIELD FABRICATED INSULATION ON ATTACHED PLENUM. AREA SERVED SERVED BY VENTILATION (OCCUPANCY) RTU -2E VENTILATION (AREA) (E)RTU-4 # OF PEOPLE CFM/PERSON CFM SQUARE FEET CFM/SF CFM JUMP AREA RTU -3 THRU 7 200 0.0 SERVING 0 19857 0.30 5957 SEATING AREA/PARTY ROOMS RTU -4,6 152 0.0 OFFICE RR 0 5608 0.30 1682 FRONT ENTRY RTU -1 8 5.0 LENNOX 40 2065 0.06 124 LOUNGE/BREAK AREA RTU -2 3 5.0 LCC180S 15 176 0.06 11 LCA060H LCA060H LCA060H LCA048H LCA060H LCA060H z TYPE ELECTRIC SUBTOTALS ELECTRIC ELECTRIC ELECTRIC ELECTRIC 55 ELECTRIC ELECTRIC 7774 ELECTRIC CUBIC FEET PER MINUTE OPERATING WEIGHT, LBS. TOTAL 0/A REQUIRED - - 7829 CFM - NOTES: 1. CALCULATIONS ARE BASED ON FMC TABLE 403.3.1.1 2. OUTDOOR AIR DEMAND IS: - 7829 CFM OUTDOOR AIR PROVIDED IS: + 8000 CFM ------------------------------ OUTDOOR AIR DIFFERENCE IS: + 171 CFM z l I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 NOTES: (NOT ALL MAY APPLY) 1. RTU IS EXISTING TO REMAIN. FIELD VERIFY ALL SPECIFICATIONS SHOWN HERE AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 2. PROVIDE ANY REQUIRED SERVICE AND MAINTENANCE REPAIRS TO BRING THE UNIT TO A 'LIKE NEW' CONDITION. REPLACE ALL WORN PARTS, BELTS AND FILTERS. COMB OUT CONDENSER FINS, LUBRICATE SHEAVES, PULLEYS AND OTHER MOVING PARTS. 3. FIELD VERIFY REFRIGERANT CHARGE AND FILL SYSTEM AS REQUIRED. IN THE EVENT THE SYSTEM IS EXTREMELY LOW, VACUUM AND CAPTURE THE EXISTING REFRIGERANT, IDENTIFY AND REPAIR LEAKS AS ENCOUNTERED. MARK SERVICE CFM E.S.P. "WG RPM MOTOR VOLTS/ PH MANUFACTURER MODEL TYPE WEIGHT NOTES EF -1 1 RESTROOMS 1 675 1 0.5 1 1550 0.125 1 120/1 1 LOREN COOK 101C15D I ROOF DOWNBLAST 1 25 1 1,2,3 NOTES: (NOT ALL MAY APPLY) 1. FAN SHALL BE FACTORY EQUIPPED WITH AN INDEPENDENT WEATHER PROOF DISCONNECT SWITCH IN SIGHT OF THE EQUIPMENT. 2. FAN SHALL RUN CONTINUOUSLY DURING HOURS OF OPERATION. 3. FAN SHALL BE FACTORY EQUIPPED WITH A GRAVITY BACKDRAFT DAMPER. MARK E RTU -1E RTU -2E RTU -3 (E)RTU-4 (E)RTU-5 (E)RTU-6 E RTU -7 E RTU -8 (E)RTU-9 (E)RTU-10 E RTU -11 SAD SERVING JUMP AREA JUMP AREA JUMP AREA JUMP AREA JUMP AREA JUMP AREA JUMP AREA JUMP AREA OFFICE RR PARTY ROOMS JUMP AREA DEVICE MANUFACTURER LENNOX LENNOX LENNOX LENNOX LENNOX LENNOX LENNOX LENNOX LENNOX LENNOX LENNOX MODEL NO. LCC180S LCC180S LCC180S LCC150S LCA060H LCA060H LCA060H LCA060H LCA048H LCA060H LCA060H z TYPE ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC CUBIC FEET PER MINUTE OPERATING WEIGHT, LBS. - - - - - - - - - - - OVER WHITE LAMINATE NAMEPLATE WITH 2" LETTERS VISIBLE ADJACENT TO LENGTH, WIDTH, HEIGHT - - - - - - - - - - - 12. MINIMUM EER - - - - - - - - - - - INTERNALLY LINED AND PINNED WITH MINIMUM R-8, 1-1/2" INSULATION DUCT. REFER TO PLAN FOR SIZE WITH VAPOR BARRIER PER THE 2017 FLORIDA MECHANICAL CODE WITH LOCAL AMENDMENTS. INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. REFER TO ARCHITECTURAL II, I I III ALL HVAC SUPPLY AND RETURN CONCEALED RIGID DUCTWORK TO BE o EXTERNALLY WRAPPED AND SECURED WITH MINIMUM R-8, 2" INSULATION VOLTS PH HZ 460/3/60 460/3/67 460/3/67 460/3/67 460/3/65* 460/3/67 460/3/60 460/3/60 460/3/60 460/3/6U 460/3/60 ALL RECTANGULAR, ROUND, AND FLEXIBLE DUCTWORK SHALL BE SIZED AS MCA (AMPS) 58 58 58 53 22 22 22 22 21 37 37 w MOCP (AMPS) 60 60 60 60 25 25 25 25 25 40 40 w �� ,:= I= I- I A FULL CERTIFIED MECHANICAL AIR TEST AND BALANCE REPORT SHALL BE m PERFORMED BY A CONTRACTOR APPROVED BY CLIENT AT THE GC'S THE ROOF CURB 21. PER THE 2017 FLORIDA MECHANICAL CODE WITH LOCAL AMENDMENTS WHEN REQUIRED, EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING FACTORY CURB WITH SUPPLY AIR CFM 4800 4800 4800 4000 2000 2000 2000 2000 1600 2000 2000 r OUTSIDE AIR CFM 1200 1200 1200 1000 500 500 500 500 400 500 500 0-2-7 ESP ("W.G.) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 O FAN RPM 811 811 811 910 1100 1100 1100 1100 1025 1100 1100 MOTOR HP 5 5 5 3 2 2 2 2 1.5 2 2 CONNECTION (NP) NOMINAL SIZE TONS 15.0 15.0 15.0 12.5 5.0 5.0 5.0 5.0 4.0 5.0 5.0 TOTAL CAPACITY (MBH) 178.8 178.8 178.8 140.1 61.5 61.5 61.5 61.5 48.1 61.5 61.5 z SENSIBLE CAPACITY (MBH) 134.1 134.1 134.1 98.1 46.1 46.1 46.1 46.1 35.6 46.1 46.1 o OUTSIDE AIR DB/WB, 'F. 94 94 94 94 94 94 94 94 94 94 94 ENTERING AIR DB/WB,-F. 80/67 80/67 80/67 80/67 80/67 80/67 80/67 80/67 80/67 80/67 80/67 SIZE AS AIR DEVICE FRAME. DISCHARGE RETURN AIR GRILL HOLD DEPTH OFF SUPPLY TYPE OF HEAT ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRICELECTRIC ELECTRIC ELECTRIC ELECTRIC z HEATING INPUT (KW) 30 30 30 30 10 10 10 I 10 10 20 20 OUTSIDE AIR DB/WB, -F. 37 37 37 37 37 37 37 37 37 37 37 T I FAVINr AIR nR /WR 'F - _ _ _ _ _ _ - _ - - z l I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 I 1_3 NOTES: (NOT ALL MAY APPLY) 1. RTU IS EXISTING TO REMAIN. FIELD VERIFY ALL SPECIFICATIONS SHOWN HERE AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 2. PROVIDE ANY REQUIRED SERVICE AND MAINTENANCE REPAIRS TO BRING THE UNIT TO A 'LIKE NEW' CONDITION. REPLACE ALL WORN PARTS, BELTS AND FILTERS. COMB OUT CONDENSER FINS, LUBRICATE SHEAVES, PULLEYS AND OTHER MOVING PARTS. 3. FIELD VERIFY REFRIGERANT CHARGE AND FILL SYSTEM AS REQUIRED. IN THE EVENT THE SYSTEM IS EXTREMELY LOW, VACUUM AND CAPTURE THE EXISTING REFRIGERANT, IDENTIFY AND REPAIR LEAKS AS ENCOUNTERED. MARK SERVICE CFM E.S.P. "WG RPM MOTOR VOLTS/ PH MANUFACTURER MODEL TYPE WEIGHT NOTES EF -1 1 RESTROOMS 1 675 1 0.5 1 1550 0.125 1 120/1 1 LOREN COOK 101C15D I ROOF DOWNBLAST 1 25 1 1,2,3 NOTES: (NOT ALL MAY APPLY) 1. FAN SHALL BE FACTORY EQUIPPED WITH AN INDEPENDENT WEATHER PROOF DISCONNECT SWITCH IN SIGHT OF THE EQUIPMENT. 2. FAN SHALL RUN CONTINUOUSLY DURING HOURS OF OPERATION. 3. FAN SHALL BE FACTORY EQUIPPED WITH A GRAVITY BACKDRAFT DAMPER. 1" Mil AND MAIN DUCT 1" MIN. ON TOP AND BOTTOM 1/4 BRANCH DUCT WIDTH, BUT MIN. 4" EQUAL TO REQ'D BRANCH DUCT DIMENSIONS SUPPLY AIRFLOW BRANCH TAKE -OFF FITTING DETAIL 4 SCALE: NONE TIE OFF TO RIGID ROUND DUCT JOINT ROOF STRUCTURE SCREWED & SEALED NYLON DRAW INSULATED SHEET METAL BAND (TYP) SUPPLY DUCT, SEALED METAL BAND PER SPECIFICATIONS SUPPORT o I I I: ?; } FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 5'-0" T -BAR TYPE/GYP SUSPENDED CEILING PROVIDE 1" BLANKET INSULATION COVERING AIR DEVICE BACK SUPPLY AIR DIFFUSER PROVIDE MANUFACTURER AVAILABLE lensl SAD RISER - SUPPLY AIR DUCT ® SAD DROP - SUPPLY AIR DUCT z CR OPPOSED BLADE DAMPER AIR BALANCING / CR CEILING REGISTER BELOW DUCT - RETURN RAD RISER - RETURN AIR DUCT z RAD DEVICE ® CE CEILING REGISTER - EXHAUST SUBSTANTIAL COMPLETION. CE CEILING REGISTER BELOW DUCT - EXHAUST ATTACH DIFFUSER BOOT TO INSULATE BOOT WITH 1" DUCTLINER GAS SERVICE (WHERE --\TRUNK (L) LINED DUCTWORK VD MANUAL VOLUME DAMPER HELD TO A MINIMUM. DUCT WITH POP FLEXIBLE CONNECTION SHOWN ON THE LOCATIONS WITH SPRINKLER PIPING, SPRINKLER HEADS AND LIGHT FIXTURES NEW DUCT TAG CFM 6. AIR DEVICE DESIGNATION QT RIVETS OR SHEETMETAL SEAL BOOT- CONNECTION AIRTIGHT DRAWINGS) SENS REMOTE TEMPERATURE SENSOR OS SD SMOKE DETECTOR ENSURE THAT AMPLE BOOT OPENINGS ARE PROVIDED TO ACCOMMODATE SCREWS POINT OF CONNECTION 8. ROOFTOP UNIT --\ELECTRICAL CUBIC FEET PER MINUTE MINIMUM 10'-0" HORIZONTAL CLEARANCE FROM THE DISCHARGE OF ANY S/A 1 9• DISCONNECT. DO NOT INSTALL OVER RETURN AIR OCCUPIED HOURS. DURING NIGHT SET -BACK HOURS, THE HVAC UNITS RIGID ROUND RETURN AIR OUTSIDE AIR 10. E/A ;ii;;i, I121 I OVER WHITE LAMINATE NAMEPLATE WITH 2" LETTERS VISIBLE ADJACENT TO ROUTE STATIC PRESSURE 11. FOH FRONT OF HOUSE THE MAXIMUM ALLOWABLE LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". BOH BACK OF HOUSE VIF VERIFY IN FIELD DIRECTLY TO THE AIR DEVICE COLLAR. 12. SUPPLY, RETURN, RESTROOM EXHAUST DUCT CONSTRUCTION SHALL BE GALVANIZED STEEL (UNO.) GAUGES, SWAY BRACING AND SUSPENSION CONDENSATE AIR AND WATERTIGHT. FLEXIBLE ALUMINUM DUCTWORK OR FIBERGLASS CONDENSER COIL DUCTBOARD IS NOT ALLOWED. UNIT LABELS OR COILS ALL HVAC SUPPLY AND RETURN EXPOSED RIGID DUCTWORK SHALL BE INTERNALLY LINED AND PINNED WITH MINIMUM R-8, 1-1/2" INSULATION DUCT. REFER TO PLAN FOR SIZE WITH VAPOR BARRIER PER THE 2017 FLORIDA MECHANICAL CODE WITH LOCAL AMENDMENTS. INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. REFER TO ARCHITECTURAL II, I I III ALL HVAC SUPPLY AND RETURN CONCEALED RIGID DUCTWORK TO BE o EXTERNALLY WRAPPED AND SECURED WITH MINIMUM R-8, 2" INSULATION DISCHARGE BACK THROUGH LOCAL AMENDMENTS. INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. POWER AND ALL PENETRATIONS IN FIRE RATED WALL ASSEMBLIES SHALL BE SEALED FIELD FABRICATED RETURN WITH UL LISTED FIRE STOPPING MATERIAL. 16. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 17. ALL RECTANGULAR, ROUND, AND FLEXIBLE DUCTWORK SHALL BE SIZED AS SHOWN ON THESE DRAWINGS; AND SHALL BE FABRICATED AND INSTALLED ACCORDING TO THE MOST RECENTLY PUBLISHED SMACNA STANDARDS. 1 I i ; I-: SEALED BY APPROVED METHODS. 18. THERMOSTAT(S) SHALL BE LOCATED AT 54" A.F.F. EXACT LOCATIONS SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL -MOUNTED WORK OR PROXIMITY TO HEAT PRODUCING EQUIPMENT. 19• CONTROL SERVICES PLENUM, CONSTRUCTED WITH THE HOOD AND FAN PACKAGE. VERIFY REQUIREMENTS FOR THE ROOF CURBS WITH THE EQUIPMENT SUPPLIER. THE GENERAL CONTRACTOR SHALL FLASH ROOF CURBS AND SHIM DEAD LEVEL. COORDINATE EXACT ® ® SIZE AND LOCATION OF ROOF OPENINGS WITH THE STRUCTURAL FRAMING. �� ,:= I= I- I A FULL CERTIFIED MECHANICAL AIR TEST AND BALANCE REPORT SHALL BE m PERFORMED BY A CONTRACTOR APPROVED BY CLIENT AT THE GC'S THE ROOF CURB 21. PER THE 2017 FLORIDA MECHANICAL CODE WITH LOCAL AMENDMENTS WHEN REQUIRED, EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING FACTORY CURB WITH AIR IN EXCESS OF 2000 CUBIC FEET PER MINUTE SHALL BE EQUIPPED OF 24 GA. SHEET METAL WITH AN AUTOMATIC SHUTOFF. AUTOMATIC SHUTOFF SHALL BE ACCOMPLISHED BY INTERRUPTING THE POWER SOURCE OF THE AIR MOVING EQUIPMENT DEVICES WHICH WILL DETECT PRODUCTS OF Al CODE, SHALL BE LABELED BY AN APPROVED AGENCY FOR AIR DUCT I 1I11 li, 1 ;; �. II((I `���( I' dill �(I=t ( � I ! � a A SHALL BE SEPERATE FROM AND NOT CONNECTED TO THE LANDLORD'S FIRE SPRINKLER AND ALARM SYSTEM. 22. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING CANT STRIP, COUNTER THE AIR FILTERS AT THE AIR HANDLING UNITS WITH PLEATED MERV 8 AND EXTERNALLY THROW AWAY TYPE AIR FILTERS AT THE COMPLETION OF CONSTRUCTION AND PRIOR TO AIR BALANCE AND STORE TURNOVER. 23. MECHANICAL CONTRACTOR SHALL BE ON SITE AND PRESENT AT THE DATE OF STORE TURNOVER. li O ROOF FLASHING, AND GASKET INSULATED FLEXIBLE DUT SUPPLY AIR DUCT ROOF DECK UNDER CONNECTION (NP) UNIT TO REMAIN FOR REFER TO MECHANICAL PLAN SOUND CONTROL FOR REFERENCED AIR DEVICE RETURN AIR UCT VERTICAL (DOWNFLOW) EXCEPT DUCT TYPE DISCHARGE. FIELD TI PENETRATION. SHEETMETAL OUTLET BOOT COORDINATE DUCT ROUTING SHALL BE FABRICATED SAME FOR HORIZONTAL SIZE AS AIR DEVICE FRAME. DISCHARGE RETURN AIR GRILL HOLD DEPTH OFF SUPPLY DUCT TO MINIMUM INTERNALLY INSULATED RECTANGU EXPOSED SUPPLY DUCT. ROOFTOP UNIT DETAIL CEILING MOUNTED RETURN AIR GRILLE 2 I EXPOSED DUCT MOUNTED DIFFUSER DETAIL 3 SCALE: NONE SCALE: NONE SCALE: NONE 1" Mil AND MAIN DUCT 1" MIN. ON TOP AND BOTTOM 1/4 BRANCH DUCT WIDTH, BUT MIN. 4" EQUAL TO REQ'D BRANCH DUCT DIMENSIONS SUPPLY AIRFLOW BRANCH TAKE -OFF FITTING DETAIL 4 SCALE: NONE TIE OFF TO RIGID ROUND DUCT JOINT ROOF STRUCTURE SCREWED & SEALED NYLON DRAW INSULATED SHEET METAL BAND (TYP) SUPPLY DUCT, SEALED METAL BAND PER SPECIFICATIONS SUPPORT o I I I: ?; } FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 5'-0" T -BAR TYPE/GYP SUSPENDED CEILING PROVIDE 1" BLANKET INSULATION COVERING AIR DEVICE BACK SUPPLY AIR DIFFUSER WITH ROUND NECK CEILING MOUNTED SUPPLY AIR DIFFUSER DETAIL ( 5 SCALE: NONE EXHAUST FAN FACTORY R00 CURB TO BE SHIMMED LEVEL. INSTALL PERROOF DECK MANUF. RECOM. SHEET METAL RISER------' TRANSITION GRAVITY BACKDRAFT FULL SIZE OF FAN DAMPER OPENING SHEET METAL EXHAUST SUPPORT DUCT RISE DUCT RISER. - WITH ALL THREAD RE: PLANS FOR SIZE SUPPORT RODS. A /_ CEILING RESTROOM DOWNBLAST EXHAUST FAN DETAIL ( 6 SCALE: NONE SYMBOL ABBR. DESCRIPTION ® CD CEILING DIFFUSER - SUPPLY EQUIPMENT ARE DRAWN TO SCALE WHEREVER POSSIBLE, THE CONTRACTOR CD CEILING DIFFUSER BELOW DUCT - SUPPLY lensl SAD RISER - SUPPLY AIR DUCT ® SAD DROP - SUPPLY AIR DUCT z CR CEILING REGISTER - RETURN / CR CEILING REGISTER BELOW DUCT - RETURN RAD RISER - RETURN AIR DUCT z RAD DROP - RETURN AIR DUCT ® CE CEILING REGISTER - EXHAUST SUBSTANTIAL COMPLETION. CE CEILING REGISTER BELOW DUCT - EXHAUST EAD RISER - EXHAUST AIR DUCT PENETRATIONS. ALL REQUIRED OPENINGS IN FOUNDATIONS, FLOORS, (L) LINED DUCTWORK VD MANUAL VOLUME DAMPER HELD TO A MINIMUM. FC FLEXIBLE CONNECTION LOCATIONS WITH SPRINKLER PIPING, SPRINKLER HEADS AND LIGHT FIXTURES NEW DUCT TAG CFM 6. AIR DEVICE DESIGNATION QT TSTAT PROGRAMMABLE THERMOSTAT (3) SENS REMOTE TEMPERATURE SENSOR OS SD SMOKE DETECTOR ENSURE THAT AMPLE BOOT OPENINGS ARE PROVIDED TO ACCOMMODATE POC POINT OF CONNECTION 8. CFM CUBIC FEET PER MINUTE MINIMUM 10'-0" HORIZONTAL CLEARANCE FROM THE DISCHARGE OF ANY S/A SUPPLY AIR 9• R/A RETURN AIR OCCUPIED HOURS. DURING NIGHT SET -BACK HOURS, THE HVAC UNITS 0/A OUTSIDE AIR 10. E/A EXHAUST AIR OVER WHITE LAMINATE NAMEPLATE WITH 2" LETTERS VISIBLE ADJACENT TO S.P. STATIC PRESSURE 11. FOH FRONT OF HOUSE THE MAXIMUM ALLOWABLE LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". BOH BACK OF HOUSE VIF VERIFY IN FIELD NOTES 1. FOR THE PURPOSE OF CLEARNESS AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZES AND LOCATIONS OF EQUIPMENT ARE DRAWN TO SCALE WHEREVER POSSIBLE, THE CONTRACTOR SHALL MAKE USE OF ALL DATA THROUGHOUT THE CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION PRIOR TO ORDERING, FABRICATING OR INSTALLING ANY MATERIALS. 2. THE MECHANICAL CONTRACTOR SHALL PROVIDE COMPLETE INFORMATION AND COOPERATE WITH THE OTHER CONTRACTORS AND TRADES AS REQUIRED FOR THE COMPLETION AND COORDINATION OF THE COMPLETE PROJECT. 3. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADMINISTERING ALL WARRANTIES ON EQUIPMENT WHICH THEY FURNISH AND INSTALL. PROVIDE WRITTEN WARRANTY TO REPLACE ALL FAULTY MATERIALS AND/OR LABOR, AT NO COST TO TENANT, FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY THE OWNER. WARRANTIES SHALL BEGIN ON THE DATE OF SUBSTANTIAL COMPLETION. 4. THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND OTHER TRADES ALL REQUIRED OPENINGS AND PENETRATIONS. ALL REQUIRED OPENINGS IN FOUNDATIONS, FLOORS, WALLS AND ROOF SHALL BE CONSTRUCTED INTO THE STRUCTURE WITH THE USE OF SLEEVES, CURBS, ETC. CUTTING AND PATCHING SHALL BE HELD TO A MINIMUM. 5. THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER LOCATIONS WITH SPRINKLER PIPING, SPRINKLER HEADS AND LIGHT FIXTURES AS REQUIRED FOR A COMPLETE INSTALLATION. 6. PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE DUCT/ PIPING CONNECTIONS TO ALL MOVING MACHINERY NOT INTERNALLY ISOLATED. 7. ALL ITEMS PROJECTING THROUGH THE ROOF SHALL BE FLASHED THROUGH CURBS OR PIPE SEALS A MINIMUM OF 12" ABOVE THE ROOF. THE PIPE CURBS AND SEALS SHALL BE INSTALLED BY THE ROOFING CONTRACTOR. ENSURE THAT AMPLE BOOT OPENINGS ARE PROVIDED TO ACCOMMODATE ANY ELECTRICAL CONDUIT PENETRATIONS REQUIRED FOR POWER. 8. ALL OUTDOOR AIR INTAKES BY MECHANICAL EQUIPMENT SHALL HAVE A MINIMUM 10'-0" HORIZONTAL CLEARANCE FROM THE DISCHARGE OF ANY EXHAUST FAN, COMBUSTION EXHAUST OR PLUMBING VENT. 9• HVAC UNITS SHALL BE SET TO RUN IN "FAN CONTINUOUS" MODE DURING OCCUPIED HOURS. DURING NIGHT SET -BACK HOURS, THE HVAC UNITS SHALL RUN IN "FAN AUTO" MODE. 10. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL 4" HIGH BLACK OVER WHITE LAMINATE NAMEPLATE WITH 2" LETTERS VISIBLE ADJACENT TO DISCONNECT SWITCH FOR HVAC UNITS AND FANS. 11. ANY FLEXIBLE DUCTS SHALL BE INSTALLED IN CONCEALED SPACES ONLY. THE MAXIMUM ALLOWABLE LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". ALL FLEXIBLE DUCTS SHALL BE CONNECTED TO BRANCH RUNS AND FITTINGS WITH A PANDUIT-TYPE BAND, AND SHALL NOT BE ATTACHED DIRECTLY TO THE AIR DEVICE COLLAR. 12. SUPPLY, RETURN, RESTROOM EXHAUST DUCT CONSTRUCTION SHALL BE GALVANIZED STEEL (UNO.) GAUGES, SWAY BRACING AND SUSPENSION SHALL CONFORM TO SMACNA STANDARDS. SEAL ALL SEAMS AND JOINTS AIR AND WATERTIGHT. FLEXIBLE ALUMINUM DUCTWORK OR FIBERGLASS DUCTBOARD IS NOT ALLOWED. 13. ALL HVAC SUPPLY AND RETURN EXPOSED RIGID DUCTWORK SHALL BE INTERNALLY LINED AND PINNED WITH MINIMUM R-8, 1-1/2" INSULATION WITH VAPOR BARRIER PER THE 2017 FLORIDA MECHANICAL CODE WITH LOCAL AMENDMENTS. INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. REFER TO ARCHITECTURAL DRAWINGS FOR DUCT PAINT OR COLOR SPECIFICATION 14. ALL HVAC SUPPLY AND RETURN CONCEALED RIGID DUCTWORK TO BE EXTERNALLY WRAPPED AND SECURED WITH MINIMUM R-8, 2" INSULATION WITH VAPOR BARRIER PER THE 2017 FLORIDA MECHANICAL CODE WITH LOCAL AMENDMENTS. INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. 15. ALL PENETRATIONS IN FIRE RATED WALL ASSEMBLIES SHALL BE SEALED WITH UL LISTED FIRE STOPPING MATERIAL. 16. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 17. ALL RECTANGULAR, ROUND, AND FLEXIBLE DUCTWORK SHALL BE SIZED AS SHOWN ON THESE DRAWINGS; AND SHALL BE FABRICATED AND INSTALLED ACCORDING TO THE MOST RECENTLY PUBLISHED SMACNA STANDARDS. ALL JOINTS, SEAMS, AND CONNECTIONS MUST BE SECURELY FASTENED & SEALED BY APPROVED METHODS. 18. THERMOSTAT(S) SHALL BE LOCATED AT 54" A.F.F. EXACT LOCATIONS SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL -MOUNTED WORK OR PROXIMITY TO HEAT PRODUCING EQUIPMENT. 19• ROOF CURBS FOR EXHAUST FAN(S) SHALL BE FACTORY FABRICATED OF FULL WELDED STEEL CONSTRUCTION WITH WOOD NAILER, AND FURNISHED WITH THE HOOD AND FAN PACKAGE. VERIFY REQUIREMENTS FOR THE ROOF CURBS WITH THE EQUIPMENT SUPPLIER. THE GENERAL CONTRACTOR SHALL FLASH ROOF CURBS AND SHIM DEAD LEVEL. COORDINATE EXACT SIZE AND LOCATION OF ROOF OPENINGS WITH THE STRUCTURAL FRAMING. CUTTING OF STRUCTURAL MEMBERS IS NOT PERMITTED. 20. A FULL CERTIFIED MECHANICAL AIR TEST AND BALANCE REPORT SHALL BE PERFORMED BY A CONTRACTOR APPROVED BY CLIENT AT THE GC'S EXPENSE. PROVIDE A COPY TO THE LANDLORD. 21. PER THE 2017 FLORIDA MECHANICAL CODE WITH LOCAL AMENDMENTS WHEN REQUIRED, EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR IN EXCESS OF 2000 CUBIC FEET PER MINUTE SHALL BE EQUIPPED WITH AN AUTOMATIC SHUTOFF. AUTOMATIC SHUTOFF SHALL BE ACCOMPLISHED BY INTERRUPTING THE POWER SOURCE OF THE AIR MOVING EQUIPMENT DEVICES WHICH WILL DETECT PRODUCTS OF COMBUSTION OTHER THAN HEAT, AND WHICH COMPLY WITH THE BUILDING CODE, SHALL BE LABELED BY AN APPROVED AGENCY FOR AIR DUCT INSTALLATION AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SMOKE DETECTORS TO BE INSTALLED SHALL BE SEPERATE FROM AND NOT CONNECTED TO THE LANDLORD'S FIRE SPRINKLER AND ALARM SYSTEM. 22. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING THE AIR FILTERS AT THE AIR HANDLING UNITS WITH PLEATED MERV 8 THROW AWAY TYPE AIR FILTERS AT THE COMPLETION OF CONSTRUCTION AND PRIOR TO AIR BALANCE AND STORE TURNOVER. 23. MECHANICAL CONTRACTOR SHALL BE ON SITE AND PRESENT AT THE DATE OF STORE TURNOVER. ARCHITECT ■ == design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezerodesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 Q 0 J LL I- Q = 0 W LL z Q O 00 r /COMMENTS SEAL ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: -- CHECKED BY.- PROJECT Y:PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. AN Rights Reserved. DRAWING NAME MECHANICAL SCHEDULES & DETAILS DRAWING NO. M201 R I*] LIGHTING PLAN - GROUND FLOOR 1/8"=1'-9' H LIGHTING PLAN MEZZAANINE 1 2 1/8"=V-0" I A. ALL WIRING SHALL BE IN CONDUIT, EMT OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC. MAXIMUM LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC. ALLOWED. B. IT'S THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO BALANCE ALL CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF CIRCUITS INDICATED. C. IN PUBLIC AREAS BATTERY PACKS FOR EXIT AND EMERGENCY LIGHTS MUST BE REMOTE OR RECESSED. PAINT EXPOSED SURFACE TO MATCH ADJACENT FINISH. D. ALL PENETRATIONS IN FIRE RATED WALL ASSEMBLIES SHALL BE SEALED WITH UL LISTED FIRE STOPPING MATERIAL. E. GENERAL CONTRACTOR SHALL LOCATE ALL EXISTING POST—TENSIONING STRANDS IN EITHER DIRECTION PRIOR TO INSTALL OF ANCHORS. IT IS IMPERATIVE THAT NO STRANDS BE DAMAGED BY THE USE OF ANCHORS. PENETRATION OF ANCHORS INTO SLAB SHALL NOT EXCEED 1 1/2". F. CONDUIT FOR LIGHTING IN WALK—IN COOLERS AND FREEZERS SHALL BE RUN ON TOP OF THE BOXES AND SEALED AIR TIGHT INTERNALLY WHERE THEY ENTER THE UNITS. ARCHITECT phase y zero design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezerodesgn.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER 1. WATTSTOPPER OR EQUAL. DUAL TECHNOLOGY WALL OR CEILING MOUNT DON PENN CONSULTING ENGINEER PASSIVE INFRARED OCCUPANCY SENSOR WITH OVER—RIDE SWITCH. (IF 1301 SOLANA BLVD. CEILING MOUNT COORDINATE OVER—RIDE PLACEMENT WITH OWNER, IF BLDG. 1 1 SUITE 1420 WALL MOUNTED OVER—RIDE SHALL BE BUILT INTO THE MODULE) WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 2• EMERGENCY, EXIT AND NIGHT LIGHTING (NL) SHALL BE CONNECTED TO THE CIRCUIT INDICATED FOR CONTINUOUS NON -SWITCHED OPERATION. 3• PROVIDE DUAL 3 -WAY WALL SWITCH FOR 50/50 CONTROL OF LIGHTING WITHIN THIS ROOM. 4. MASTER LIGHTING SWITCH BANK, SWITCHES SHALL HAVE LED INIDCATORS REFER TO DETAIL 1 SHEET E301. 5. EXISTING LIGHTING AND SWITCHING TO REMAIN. POWER WITH NEAREST NON SWITCHED LIGHTING LEG WITH CAPACITY FOR ADDITIONAL LOAD. 6• NEW/EXISTING HIGH BAY LIGHTING SHALL BE CIRCUITED AND SWITCHED AS INDICATED. LIGHTING SHALL BE ROUTED EXISTING LIGHTING CONTACTOR PANEL TO AUTOMATICALLY PROVIDE ABILITY TO SHUT OFF ALL NON EMERGENCY OR NIGHT LIGHTING OFF AFTER HOURS VIA TIME CLOCK. ALL HIGH BAY FIXTURES SHALL BE MOUNTED 19'-0" A.F.F. 7• NEW/EXISTING HIGH BAY LIGHTING SHALL BE CIRCUITED AND SWITCHED AS INDICATED. LIGHTING SHALL BE ROUTED EXISTING LIGHTING CONTACTOR PANEL TO AUTOMATICALLY PROVIDE ABILITY TO SHUT OFF ALL NON EMERGENCY OR NIGHT LIGHTING OFF AFTER HOURS VIA TIME CLOCK. ALL HIGH BAY FIXTURES SHALL BE MOUNTED 21'-0" A.F.F. 8• PROVIDE LINEAR LED STRIP LIGHTING IN EXISTING SOFFIT 013'-11" A.F.F. 9• PROVIDE NEW EMERGENCY/NIGHT LIGHTING FIXTURE. FIXTURE SHALL BE ORDERED FROM FACTORY WITH EMERGENCY BATTERY PACK CAPABLE OF ENERGIZING THE FIXTURE FOR 90 MINUTES UPON THE LOSS OF COMMERCIAL POWER. FIXTURE SHALL BE NON SWITCHED AND PROVIDE CONTINUOUS ILLUMINATION. FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 0 Q 0 ry Q W Z R 0 00 J LL 0 LL Q I REV I DATE I DESCRIPTION/ COMMENTS I SEAL if ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: -- CHECKED BY: -- PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp, All Rights Reserved DRAWING NAME LIGHTING FLOOR PLAN DRAWING NO. E101 '-6"A.F.F. 111 vJ RTU -10 P1-40 )4 POWER PLAN - GROUND FLOOR 1/8"=V-0" 1 POWER PLAN - MEZZANINE 1 2 1/8"=1'-0" A. JELECTRICAL CONTRACTOR TO COODRINATE RECEPTACLE MOUNTING HEIGHT, CONFIGURATION OF EQUIPMENT LOCATIONS AND REQUIREMENTS OF EQUIPMENTS WITH ARCHITECTURAL MILLWORK DRAWING PRIOR TO ROUGH -IN ELECTRICAL DEVICES. B. ALL WORK SHOWN SHALL COMPLY WITH THE 2014 NEC IN ADDITION TO ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODE ORDINANCES, ETC. C. ELECTRICAL CONTRACTOR SHALL VERIFY AND PROVIDE ALL CONDUIT AND WIRE FOR CONNECTION TO ALL ELECTRICAL DEVICES, PER MANUFACTURERS'S INSTALLATION INSTRUCTIONS. D. COLOR OF RECEPTACLES AND COVERPLATES ARE TO COMPLIMENT SURROUNDING WALL (E.G.: BROWN/BROWN IN WOOD PANELING, ETC). E. ALL RECEPTACLES IN "PUBLIC" AREAS ARE TO HAVE PLASTIC "CHILD GUARDS." F. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF ANY RATED PARTITIONS 1AS REQUIRED. 1. JUNCTION BOX ABOVE CEILING WITH CONDUIT ROUTED TO WIREMOLD ABOVE COUNTER AT 3'-6" AFF. PROVIDE RECEPTACLES AS NOTED. 2. NEW ELECTRICAL DISTRIBUTION GEAR. REFER TO RISER DIAGRAM. 3. PROVIDE SUPERVISORY SIGNAL ANNUNCIATION FOR SMOKE DETECTORS IN MANAGERS OFFICE FOR RTU'S. 4. RESTROOM EXHAUST SHALL BE INTERLOCKED WITH HVAC SYSTEM. REFER TO MECHANICAL DRAWINGS. 5. PROVIDE USB COMBO RECEPTACLE FOR CUSTOMER USAGE. 6. PROVIDE NEW JUNCTION BOX AND MOTOR RATED SWITCH FOR MEANS OF DISCONNECT PER NEC FOR NEW STOREFRONT SIGNAGE. COORDINATE LOCATION OF JUNCTION BOX WITH OWNER PRIOR TO ROUGH -IN. SIGNAGE SHALL BE CONTROLLED VIA TIME CLOCK AND PHOTOCELL. 7. RECEPTACLE TO BE MOUNTED AT 9'-0" A.F.F (6'-0" ABOVE PLATFORM). COORDINATE LOCATION WITH OWNER. 8. MOUNT "SHOW WINDOW" RECEPTACLES IN BULKHEAD AT TOP OF WINDOW. COORDINATE LOCATION WITH OWNER. 9. PROVIDE COLUMN MOUNTED RECEPTACLE AND DATA AT 9'0" A.F.F. FOR TELEVISION. 10. PROVIDE ELECTRICAL CONNECTION AS REQUIRED FOR SCENT DISPENSER. COORDINATE DEVICE AND MOUNTING HEIGHT AND CONNECTION REQUIREMENTS WITH OWNER PRIOR TO ROUGH -IN. 11. ROUTE ALL DATA AND POWER FOR POS AND RECEPTACLES IN RACEWAY IN MILLWORK. 12. WALL HUNG TELEVISION RECEPTACLES AND DATA TO BE MOUNTED AT 6'-0" AFF. 13. RECEPTACLE TO BE MOUNTED AT 11'-0" A.F.F (6'-0" ABOVE PLATFORM). COORDINATE LOCATION WITH OWNER. 14. PROVIDE NEW INSTANTANEOUS WATER HEATER FOR BREAK ROOM SINK. MOUNT RECEPTACLE UNDER SINK IN CABINET. 15. EXISTING RTU TO REMAIN. VERIFY ALL EXISTING ELECTRICAL CONNECTIONS PER NEC AND MANUFACTURER. REPAIR OR REPLACE ANY DAMAGED EQUIPMENT REQUIRED FOR PROPER UNIT OPERATION AND CONTROL. VERIFY EXISTING UNIT HAS SMOKE DETECTOR IN RETURN AIR SIDE AND IS OPERATIONAL, PROVIDE NEW IF NECESSARY. 16. PROVIDE NEW GFI/WP/WR RECEPTACLE ON ROOF FOR MAINTENANCE OF ROOFTOP UNIT IF NOT EXISTING, CIRCUIT TO P1-39. 17. QUAD RECEPTACLE MOUNTED BELOW COUNTER VIA WIREMOLD EQUIVALENT TO 2400 SERIES. 18. RECEPTACLE TO BE MOUNTED AT 1'-6" A.F.F (BELOW PLATFORM). COORDINATE LOCATION WITH OWNER. 19. PROVIDE JUNCTION BOXES ABOVE CEILING AND CIRCUIT FOR POWER TO LOW VOLTAGE DOOR CONTROL MODULE. 20 PROVIDE RECEPTACLE' MOUNTED TO UNDERSIDE OF 3' PLATFORM FOR WIPE-OUT AREA AND REACTION WALL. A. ELECTRICAL CONTRACTOR SHALL MAKE A THROUGH SURVEY OF EXISTING CONDITIONS AND OF THE ELECTRICAL SYSTEM TO FAMILIARIZE HIMSELF, IN ORDER TO INSTALL THE NEW ELECTRICAL SYSTEM PROPOSED, PRIOR TO BID/CONSTRUCTION. B. ALL EQUIPMENT SCHEDULE TO BE REUSED, SHALL BE RECONDITIONED TO LIKE NEW STATUS. IF COST TO REPAIR OR RECONDITION EXCEEDS NEW COST, THEN THE EQUIPMENT SHALL BE REPLACED. C. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE OF RECONNECTING ALL ELECTRICAL EQUIPMENT IN ORDER TO HAVE A COMPLETE WORKING JOB, WHETHER OR NOT THE EQUIPMENT IS SHOWN ON NEW ELECTRICAL PLANS. D. DUE TO THE NATURE OF THIS PROJECT, THE ELECTRICAL CONTRACTOR MUST CHECK OUT ALL EXISTING CIRCUITS STARTING AT THEIR DISTRIBUTION POINT IN ORDER TO SEE IF THEY ARE STILL ENERGIZED. E. WHEN INSTALLING NEW EQUIPMENT, THE ELECTRICAL CONTRACTOR SHOULD USE EXISTING CONDUITS AND AVAILABLE CIRCUITS, IF POSSIBLE. ALL REUSED CIRCUIT BREAKERS, OUTLETS, SWITCHES, ETC SHALL BE INSPECTED AND REPLACED AS NEEDED. F. SPACES HAVE BEEN LEFT IN PANELBOARDS, SO THAT EQUIPMENT OR CIRCUITS MISSED MAY BE CONNECTED. G. ALL ELECTRICAL EQUIPMENT REMOVED SHALL BE KEPT IN A SECURE AREA UNTIL OWNERS DECIDE WHAT TO DO WITH IT. H. THE ELECTRICAL CONTRACTOR SHALL NOT OVERLOAD ANY EXISTING PANELBOARDS OR FEEDERS AND SHALL NOT EXCEED 80 PERCENT OF THEIR RATED VALUE. I. ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT PRIOR TO INSTALLATION. J. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY PROBLEMS DURING CONSTRUCTION BEFORE PROCEEDING WITH THE PROJECT. K. THE INTENT OF THE ELECTRICAL DESIGN IS TO UTILIZE AS MUCH OF THE ELECTRICAL EQUIPMENT AS POSSIBLE, THEREBY ELIMINATING EXCESSIVE COST, CONSTRUCTION AND TIME. ARCHITECT phase zero design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezemdesign.com CLIENT JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 I SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 m U W 0 O CL CL a O Q w Z E O T_ oo T_ J LL REVISIOS N REV T DATE I DESCRIPTION/COMMENTS SEAL m O :C0 C } /��► to *101��/ III p ``,• ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: -- CHECKED BY: -- PROJECT NUMBER: 2118015 Copyngh( (c) by Phase Zero Design Corp_ All Rights Resewed DRAWING NAME POWER PLAN DRAWING NO. E102 ARCHITECT phase zero TELEPHONE SYSTEM RISER DIAGRAM 2" EMPTY CONDUIT WITH PULLWIRE FOR design TELEPHONE SERVICE TO FACILITY. 1. VERIFY, COORDINATE AND INCORPORATE THE 35 POND PARK ROAD, BAY 16 REQUIREMENTS OF THE TELE. CO. AND ALL HINGHAM, MA 02043 GOVERNING CODES IN FORCE, PRIOR TO PHONE: (781)452-7121 COMMENCEMENT OF WORK. FAX: (781) 875-3039 www.Masezerodesign.com 2. FURNISH AND INSTALL A RACEWAY SYSTEM OF TELEPHONE COMPANY CLIENT CABLE AND 3/4" CONDUIT AND PROPERLY APPROVED CONNECTOR r, SIZED JUNCTION BOXES WITH COVERPLATES CEILING JUMP 2018 LLC FOR THE TELEPHONE SYSTEM AS SHOWN ON10108 EVERGREEN LANE DRIVE THE DRAWINGS AND IN THE DIAGRAM. u DSL ALARM FILTER TAMPA, FL 33647 PHONE: (813) 838-8896 3. ALL CONDUIT SHALL ORIGINATE AT THE #6 AWG SOLID CU. " STUB SECURITY c� RJ31 X CONNECTOR 3/4" EMPTY CONDUIT TO ABOVE JUNCTION BOXES, BE NO SMALLER THAN 3/4" "THW" INSULATED CONDUIT WITH ACCESSIBLE CEILING. ELECTRICAL TRADE SIZE, BE CONTINUOUS AND GROUND EXTENDED ® ® PULLWIRE TYPICAL ELECTRICAL ENGINEER TERMINATE AT THE SYSTEM TERMINAL BOARD FROM MAIN SERVICE TYPICAL swrTCH 'A71 ALL LIGHTING SHALL BE CONTROLLED VIA NEATLY CLAMPED AND WITH BUSHED ENDS. GROUND 120V. WP DUPLEX EXISTING LIGHTING CONTROL PANEL. HOME RUNS SHALL BE LIMITED TO ONE (1) RECEPTACLE m m m SWITCH BANK SHALL PROVIDE LOCAL TELEPHONE OUTLET IN ONE 3/4" CONDUIT. - SECURITY OVER -RIDE MANUAL CONTROL OF MAIN FLOOR LIGHTING. 4. THERE ARE MULTIPLE DEDICATED TELEPHONE 120V. WP DUPLEX . LINES AND THEY SHALL BE SEGREGATED FROM RECEPTACLE EACH OTHER AND SHALL BE SEGREGATED FROM 2'-O" WIDE X 3'-0" HIGH X 3 " 48" THE STANDARD TELEPHONE LINES. /4 ® g TO 5. FURNISH AND INSTALL A PAINT GRAFF THICK AY AND MOUNTOOD BOARD. SEAL, m m m 200 LB TEST NYLON 0 WALL. z DON PENN CONSULTING ENGINEER PULL LINE IN ANY EMPTY CONDUIT. TAG EACH MAIN FLOOR MAIN FLOOR MAIN FLOOR O END OF PULL LINE AS TO SERVICE AND THE 120 VOLT POWER FOR a= a 1301 SOLANA BLVD. LIGHTING UCHnNG UGHnNG LOCATION OF THE OPPOSITE TERMINUS OF THE TELEPHONE SYSTEM. CLAMP AND BUSH END. cv w U BLDG. 11 SUITE 1420 TYPICAL FOR EACH a J a U CONDUIT. DEDICATED BRANCH HOMERUN TERMINATION. N 0 TLAKE8157.410.2, TX 76262 858 F 817.251.8411 CIRCUIT P 1-26 I 6. ALL CONDUITS SHALL CONTAIN ONE (1) HIGH FLORIDA ENGINEER NO. 0051096 (MECH) NOTE: QUALITY 4 PAIR CAT III PLENUM CABLE MECHANICAL & PLUMBING ENGINEER PROVIDE THE REQUIRED NUMBER OF SWITCHBOXES FOR A NEAT, UNIFORMLY SPACED TELEPHONE LINES PULLED WITH PROPER INSTALLATION AS SHOWN. CONTRACTOR TO MATCH LOAD TYPE AND DERATE WATTAGE. INSTALLED JACKS. LINES MUST BE LABELED AT FLOOR PROVIDE NOMENCLATURE SPECIFYING WHICH LUMINAIRES ARE CONTROLLED BY WHICH TELEPHONE BOARD. IDSTUDI04 CONTROLLER. VERIFY NOMENCLATURE WITH OWNER AND ARCHITECT. VERIFY COLOR 1431 GREENWAY DRIVEIRVING, TX 75038 SELECTION WITH ARCHITECT. PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 SWITCH BANK DETAIL TYPICAL TELEPHONE SYSTEM RISER DIAGRAM NOT TO SCALE NOT TO SCALE I PHOTOELECTRIC CONTROL SEE SCHEDULE STRt)CTURa1 r- TORK 2101 24 HR. TIMECLOCK EQUAL TO FOR VOLTAGE (EFALk JOIST. SLAEL M-) — — TORK 1101. VERIFY SETTING LOW VOLTAGE OF HOURS FOR CONTROL CONDUIT BY �I DIV. 16 ELEC. POWER TM TM W AC -UNIT Z 0 P1-26 Q J 0 O WJ ROOM SWITCH, LIGHTING RELAY OR OCCUPANCY SENSOR � � ALL THREAD - 1 2 1 2 C � � LL —) SMOKE BEAM ORSIZE REGILRIED R G Y Y W W (HOT) FIXTURE BALLAST DETECTOR Q 0 SUPPORT. AS B'K' BLACK HOT C CONTACT--,,,..,, = 0 Q 1L BL EXTERIOR SIGNAGE W P1-17 24V LOW/18GA. VOLTAGE (TYP.) Z Z W FIXTURE AC BALLAST SPARE BY E.C. CLAMP - 3W TO 10 F LANISTMIT 2 P1ECE +�h44NNEt SPARE O PIPE. STRAPS- f 1!fi' TC7' 3��� --� F— I � W .; - ,.. ROOM T -STAT W SPARE —�--� �---�— R G Y Y W W C LOCATED IN THE � 00 1 2 1 2 OFFICE. FIELD Q � I:INWRIJT __%?EAS 4 -POLE MECH. HELD LIGHTING CONTROL RELAY IN VERIFY EXACT JUNCTION BOX EMERGENCY BALLAST NEMA 1 ENCLOSURE WITH LINE VOLTAGE COIL AND PROGRAMMABLE ROOM THERMOSTAT LOCATION RBC$tIR1 8Y WEIt TT RED (HOT) AUXILIARY MODULE FOR 2 WIRE 120 VAC CONTROL. RACEWAY 3d4' TO f' WHITE (NEUTRAL) RELAY SHALL BE EQUAL TO ASCO 918 SERIES. �1' L T Y E.C. (TYP.) 18 GA. WIRE BE NOTE. REMOTE SENSOR, SEE Q EXTERIOR LIGHTING CONTROLS SHALL BE PHOTOCELL FLOOR PLAN FOR LOCATION ON/TIMECLOCK OFF CONTROL. VERIFY SETTING OF HOURS FOR CONTROL. TYPICAL CONDUIT RACK 3 EMERGENCY LIGHTING WIRING DIAGRA NOT TO SCALE M 4 LIGHTING CONTROL DIAGRAM THERMOSTAT WIRING DIAGRAM NOT TO SCALE NOT TO SCALE NOT TO SCALE U W O It Q_ REVISIONS REV DATE DESCRIPTION COMMENTS ST TUi RAIL UW --- - CAI_/_ STEEL 4 X 4' BOX WMVER ON BOX AS REQ1D. T -BAR LOCK CLIPr SEAL 314" CONDUIT 1 , FLEX HANGER WIRE BEAM CLAMP EAM RE{ IR HA AGE ,� ••••* •• a���� ,,; EY REQALLF IRED N �1 SUPPORTED. : 2 : � LL. s,• � �� FUCTURES ALLL THREAD SSE NOTF- � W :ZCORNIERS OF AS FIl2=RED TIE WIRE SHALL. NOT HE U5EDAS _ a : w A SIL INT OF ANY RACEWAY ;L) o H GRID HANIGERSYSIEW . j Z m T -BREI •••• •• 0��,,, RACY, 3I4" 7HM jr �� •' ...... • `, STRAIGHT CONNECTOR CELL. NG CCOUNr HAND FOR 117 FLEX ' TILE STRUCTURAL. IJWT ' FDffURF WITH 32 WATT' {' 'WIRING '� TVS RAPID START 6614141 CLALV3S (TR � ADAPTER LAMPS. TYPE SHOWN HANGER CLAMP ISSUED FOR: PERMIT - BID PLATE ON symom DRAWING, REQUIRM BYISSUED DATE: 04.04.2018 j DESCRIPTM ON WEIGHT ��ORTID . PLANS. DRAWN BY: -- T4MR LOCI( CLIP (2 REQ Db ''•-- RACEWAY - 3N' THIW 11 CHECKED BY: -- PER FIXTURE). SECURE FIXTURE TO T -BAR AT OPPOSITE CORNERS_ RPROJECT NUMBER: 2118015RACEWAY - 3f4' Tt-�U 1r Copyright (c) by Phase Zero Design Corp. All Rights Reserved. DRAWING NAME ELECTRICAL DETAILS DRAWING NO. NOT USED10 E201 NOT TO SCALE NOT USED 9 TYPICAL RECESSED FIXTURE MOUNTING DETAIL 8 TYPICAL RACEWAY SUPPORT DETAIL NOT TO SCALE NOT TO SCALE NOT TO SCALE EX PANEL MDP 800A MCB 2771 480 V, 3PH, 4W.+GRND. WIRE PHASE 42K AIC RATED OCP VA CCT SERVES : VA OCP WIRE PHASE WIRE 2#12,#12G.,3/4"C. OCP VA SERVES' CCT 3500 GENERAL LIGHTING 1 EX AC -1 12830 60/3 EXISTING CIRCUIT A EXISTING CIRCUIT B 150/3 14218 EX PANEL "LP1" 2 GENERAL LIGHTING 4 5 GENERAL LIGHTING 12830 HACR - B - 2#12,#12G.,3/4"C. HACR 15030 - GENERAL LIGHTING 6 7 GENERAL LIGHTING 3150 12830 - - C - 20/1 - 14050 - 8 9 GENERAL LIGHTING 3 EX AC -2 12830 60/3 EXISTING CIRCUIT A EXISTING CIRCUIT 3150 35013 12058 EX TRANSFORMER "T1" 4 WAREHOUSE LIGHTING 2250 20/1 EXISTING CIRCUIT 12830 HACR - B - IGENERAL LIGHTING - 11698 - SPARE ISPARE 20/1 17 A 12830 - - C - 14 - 11867 - 19 20/1 864 5 EX AC -3 12830 60/3 EXISTING CIRCUIT A EXISTING CIRCUIT 17 2513 3373 EX AC -8 6 2#12,#12G.,314"C. C 2#12,#12G.,3/4"C. 20/1 12830 HACR - B - SPARE HACR 3372 - 20/1 A 24 20/1 SPARE 12830 - - C - 20/1 - 3373 - B SPARE _ 7 EX AC -4 116.90 60/3 EXISTING CIRCUIT A EXISTING CIRCUIT 20/1 2513 3220 EX AC -9 8 20/1 C - SPARE 24 11690 HACR - g - 2011 HACR 3220 - 20/1 850 EX. EXTERIOR LIGHTING 26 27 11690 - - C - B - 3220 - 400 EX. FRONT CANOPY LIGHTING 28 9 EX AC -5 3373 25/3 EXISTING CIRCUIT A EXISTING CIRCUIT 37 4013 5673 EX AC -10 10 30 31 SPARE SPARE 3373 HACR - B - 20/1 HACR 5673 - 32 33 SPARE 41 20/1 3373 - - C - 20/1 - 5673 - 35 SPARE 720 i1 EX AC -6 3373 25/3 EXISTING CIRCUIT A EXISTING CIRCUIT SPARE 40/3 5673 EX AC -11 12 720 20/1 2#12,#12G.,3/4"C. A 3373 HACR - B - 38 HACR 5673 - 800 20/1 2#12,#12G.,3/4"C. B - 3373 - - C - 41 - 5673 - 20/1 EXISTING CIRCUIT C 13 EX AC -7 3373 2513 EXISTING CIRCUIT A EXISTING CIRCUIT 6013 3330 EX COMPACTOR 14 3373 HACR - B - - W30 - 3373 - - C - - W30 - _. NOTES: 1 2 3 4 PANEL IS EXISTING TO REMAIN VERIFY ALL CRCUITS AND BREAKERS . _ .__ _ _.... _ _. _ _ _._ PROVIDE COPPER BUS ALL CIRCUITS AND BREAKERS ARE EXISTING TO REMAIN. LOAD SUMMARY CONN NEC DEM LOAD BALANCE PER PHASE 1 -LIGHTING 45698 1.25 571233 PHASE A 107844 2 -RECEPTACLES 24760 NEC 17380 PHASE B 108295 3 -KITCHEN 2476 0.65 1609.4 PHASE C 107485 4-HVAC243913 1 243913 LOWEST PHASE PLUS 10% 5 -NON -CONT 11377 1 11377 107485 + 10Yo 118234 LARGEST MOTOR 0 0.25 0 PHASES ARE BALANCED' TOTAL VA 3282241 1 331402 TOTAL ANDS 1 394.81 1 398.6 EX PANEL LPI 225A MLO 277/ 480 V, 3PH, 4W.+GRND., 42K AIC RATED CCT SERVES VA OCP WIRE PHASE WIRE OCP VA SERVES CCT 1 GENERAL LIGHTING 2800 20/1 2#12,#12G.,3/4"C. A 2#12,#12G.,3/4"C. 20/1 3500 GENERAL LIGHTING 2 3 GENERAL LIGHTING 3150 2011 2#12,#12G.,3/4"C. B 2#12,#12G.,3/4"C. 20/1 3500 GENERAL LIGHTING 4 5 GENERAL LIGHTING 3150 20/1 2#12,#12G.,3/4"C. C 2#12,#12G.,3/4"C. 20/1 3150 GENERAL LIGHTING 6 7 GENERAL LIGHTING 3150 20/1 2#12,#12G.,3/4"C. A 2#12,#12G.,3/4"C. 20/1 3150 GENERAL LIGHTING 8 9 GENERAL LIGHTING 3150 2011 2#12,#12G.,3/4"C. B 2#12,#12G.,3/4"C. 20/1 3150 1GENERAL LIGHTING 10 11 WAREHOUSE LIGHTING 2250 20/1 EXISTING CIRCUIT C 2#12,#12G.,3/4"C. 20/1 2450 IGENERAL LIGHTING 12 13 SPARE ISPARE 20/1 17 A 2#12,#12G.,3/4"C. 20/1 768 ENTRY STRIPS 14 15 SPARE 19 20/1 864 B 2#12,#12G.,3/4"C. 20/1 1680 2x4 LIGHTING 16 17 SPARE 864 20/1 2#12,#12G.,314"C. C 2#12,#12G.,3/4"C. 20/1 2250 2x4 LIGHTING 18 19 SPARE 900 20/1 20/1 A 24 20/1 SPARE SPARE 20 21 SPARE 20/1 20/1 26 B SPARE 20/1 20/1 SPARE 22 23 SPARE 28 20/1 SPARE C 20/1 20/1 C - SPARE 24 25 SPARE SPARE 20/1 2011 A EXISTING CIRCUIT 20/1 850 EX. EXTERIOR LIGHTING 26 27 SPARE 20/1 20/1 B - B EXISTING CIRCUIT 20/1 400 EX. FRONT CANOPY LIGHTING 28 29 SPARE C - 20/1 SPARE C 37 20/1 1500 SPARE 30 31 SPARE SPARE 20/1 39 A 2#101013.,3/4"C. 20/1 1238 SPARE 32 33 SPARE 41 20/1 2#12,#12G.,3/4"C. 13 20/1 20/1 SPARE 34 35 SPARE 720 20/1 2#12,#12G.,314"C• C 2#12,#12G.,3/4"C. 20/1 720 SPARE 36 37 SPARE 720 20/1 2#12,#12G.,3/4"C. A - 20/1 800 SPARE 38 39 SPARE 800 20/1 2#12,#12G.,3/4"C. B - 20/1 1000 SPARE 40 41 JEX. POWER ROOM LIGHTING 800 20/1 EXISTING CIRCUIT C 2#12,#12G.,3/4"C. 20/1 1000 SPARE 42 NOTES: 1 PROVIDE BOLT ON BREAKERS 2 PROVIDE TYPED PANEL DIRECTORY LOAD SUMMARY CONN NEC DEM LOAD BALANCE PER PHASE PHASE WIRE 1 -LIGHTING 43298 1.25 54123 PHASE A 14218 2 -RECEPTACLES 0 NEC 0 PHASE B 15030 3 -KITCHEN 0 0.65 0 PHASE C 14050 4 -HVAC 0 1 0 LOWEST PHASE PLUS 10% 2#12,#12G.,3/4"C. 5 -NON -CONT 0 1 0 14050 + 10% 15455 LARGEST MOTOR 0 0.25 0 PHASES ARE BALANCED 2 TOTAL VA 43298 54123 TOTAL AMPS 52.1 65.1 INSTA HOT WATER HEATER EX. PANEL P 175A MLO 120/ 208 V, 3PH, 4W.+GRND., EXISTING AIC RATED GCT SERVES VA OCP WIRE PHASE WIRE OCP VA SERVES CCT 1 INSTA HOT WATER HEATER 1500 20/1 2#12,#12G.,3/4"C. A - 20/1 SPARE 2 3 INSTA HOT WATER HEATER 1500 20/1 2#12,#12G.,3/4"C. B - 20/1 SPARE 4 5 USB RECEPT 1000 20/1 2#12,#12G.,3/4"C. C - 20/1 SPARE 6 7 SPARE 277 20/1 2#12,#12G.,3/4"C. A - 20/1 SPARE 8 9 CONVIENCE RECEPTS USB 360 20/1 2#12,#12G.,3/4"C. B - 20/1 SPARE 10 11 CONVIENCE RECEPTS USB 1000 20/1 2#12,#12G.,3/4"C. C - 20/1 SPARE 12 13 CONVIENCE RECEPT. 800 20/1 2#12,#12G.,3/4"C. A - 20/1 SPARE 14 15 CONVIENCE RECEPT. 500 20/1 2#12,#12G.,3/4"C. B - 20/1 ISPARE 16 17 CONVIENCE RECEPT. 1200 2011 2#12,#12G.,3/4"C. C - 20/1 SPARE 18 19 MOTORIZED GRILLE 864 15/1 2#12,#12G.,3/4"C. A - 20/1 SPARE 20 21 MOTORIZED GRILLE 864 15/1 2#12,#12G.,314"C. B - 20/1 SPARE 22 23 ISPARE 19 20/1 900 C - 20/1 SPARE 24 25 SPARE CONVIENCE RECEPTACLES 20/1 21 A - 20/1 ISPARE 26 27 SPARE 20/1 20/1 CONVIENCE RECEPTACLES B - 2011 SPARE 28 29 SPARE C 20/1 20/1 C - 20/1 SPARE 30 31 SPARE 20/2 2011 A A - 20/1 SPARE 32 33 SPARE BREAK ROOM REFRIG. 20/1 HACR B - 20/1 SPARE 34 35 SPARE 28 20/1 IBREAK ROOM MICROWAVE C - 20/1 SPARE 36 37 SPARE 1500 20/1 30 A - 20/1 SPARE 38 39 SPARE 2#101013.,3/4"C. 20/1 1238 B - 20/1 SPARE 40 41 SPARE 2#12,#12G.,3/4"C. 20/1 C - 20/1 SPARE 42 NOTES: 1 PROVIDE BOLT ON BREAKERS 2 PROVIDE TYPED PANEL DIRECTORY LOAD SUMMARY CONN NEC DEM LOAD BALANCE PER PHASE WATTS 1 -LIGHTING 0 1.25 0 PHASE A 3164 2 -RECEPTACLES 9588 NEC 9588 PHASE B 3224 3 -KITCHEN 0 0.65 0 PHASE C 3200 4 -HVAC 0 1 0 LOWEST PHASE PLUS 10% 128 5 -NON -CONT 0 1 0 3164 + 10% 3480.4 LARGEST MOTOR 0 0.25 0 PHASES ARE BALANCED A -EM TOTAL VA 9588 9588 TOTAL AMPS 1 26.61 1 26.61 1 EXISTING COMPAN' TRANSFC ROOF BLDG. ELEC RM LIGHT FIXTURE SCHEDULE SYM. MANUF. CATALOG NUMBER NO. LAMPS/TYPE WATTS VOLTS MOUNTING REMARKS A LITHONIA 2AVG-332—MDR—MVOLT—GEB101S 2X4 FLUORESCENT FIXTURE 128 277 LAY—IN A A -EM LITHONIA 2AVG-332—MDR—MVOLT—GEB101S 2X4 FLUORESCENT FIXTURE 128 277 LAY—IN EQUIPPED WITH EL14 (MIN 70OLMN) EM BATT PACK B CREE KBL—A—UVM4OK7UL LED HIGH BAY FIXTURE 142 277 SUSPENDED NOTE 6. MOUNT BOF 021'—O"AFF MINIMUM BE/NL CREE KBL—A—UVM4OK7UL LED HIGH BAY FIXTURE 142 277 SUSPENDED PROVIDE BATTERY PACK FOR 90MIN EMERGENCY OPERATION; NOTE 6. MOUNT BOF 021'-0"AFF MINIMUM C SLOANLED COLORLINE LINEAR PURPLE LED STRIP 25 — SURFACE PROVIDE TRANSFORMER FOR LOW VOLTAGE PER MANUF. EX EXISTING EXISTING FIXTURE TO BE REUSED EXISTING — — SUSPENDED CLEAN AND RELAMP X BRADYGLO #878076 INCLUDED 5 277/120 SURFACE/SUSPENDED EXIT LIGHT EM PHILLIPS LLNURW INCLUDED 1.8 277/120 SURFACE/SUSPENDED DOUBLE SIDED EMERGENCY UNIT WITH 90 BATTERY PACK EX. PANEL P1 LUMINAIRE SCHEDULE NOTES: 1. ALL FLUORESCENT LIGHTING SHALL BE PROVIDED WITH INTEGRAL DISCONNECTING MEANS. 2. COORDINATE THE MOUNTING LOCATION WITH THE OWNER'S CONSTRUCTION PROJECT MANAGER OR ARCHITECT. 3. PROVIDE ADDITIONAL BALLAST FOR INBOARD/OUTBOARD DUAL SWITCHING. 4. LENS AND/OR SHATTERPROOF FIXTURES SHALL BE PROVIDED IN ALL FOOD PREPARATION AREAS. 5. PROVIDE CURRENT LIMITING DEVICES ON ALL TRACK LIGHTING SIZED ADEQUATELY FOR HEADS INSTALLED. 6. COORDINATE FIXTURE FINISH AND COLOR WITH OWNER PRIOR TO PURCHASE 175A MLO 120/ 208 V, 3PH, 4W.+GRND., EXISTING AIC RATED CCT SERVES VA OCP WIRE PHASE WIRE OCP VA SERVES CCT 1 CASHWRAP 1000 20/1 2#12,#12G.,3/4"C. A 2#12,#12G.,3/4"C. 20/1 720 RESTROOM GFI 2 3 CASHWRAP 1000 20/1 2#12,#12G.,3/4"C. B 2#12,#12G.,3/47C. 20/1 800 MERCHANDISER 4 5 MAIN ENTRY DOOR CONT. 360 20/1 2#12,#12G.,3/4"C. C 2#12,#12G.,3W'C. 20/1 1200 BREAK ROOM MICROWAVE 6 7 SHOW WINDOW RECEPT 1200 20/1 2#12,#12G.,3/4"C. A 2#12,#12G.,3/4"C. 20/1 800 BREAK ROOM RECEPT 8 9 SCENT DISPENSERS 500 20/1 2#12,#12G.,3/4"C. B 2#12,#12G.,3/4C. 20/1 800 JUMP ZONE RECEPTACLE 10 11 SECURITY MONITORS 500 20/1 2#12,#12G.,3/4"C. C 2#12,#12G.,3/4"C. 20/1 800 MERCHANDISER 12 13 PARTY ROOM RECPTS 720 20/1 2#12,#12G.,3/4"C. A - 20/1 1000 WAIVER 14 15 PARTY ROOM RECPTS 720 20/1 2#12,#12G.,3/4"C. B 2011 1000 WAIVER 16 17 SIGNAGE 1200 20/1 2#12,#12G.,3/4"C. C 20/1 SPARE 18 19 IBREAK ROOM COLD STORAGE 900 20/1 2#12,#12G.,3/4"C. A 2#12,#12G.,3/4"C. 20/1 360 CONVIENCE RECEPTACLES 20 21 BREAK ROOM COLD STORAGE 900 20/1 2#12,#12G.,3/4"C. B 2#12,#12G.,3/4"C. 20/1 720 CONVIENCE RECEPTACLES 22 23 BREAK ROOM COLD STORAGE 900 20/1 2#12,#12G.,3/4"C• C 2#12,#12G.,3/4"C. 20/1 800 OFFICE RECEPT 24 25 BREAK ROOM COLD STORAGE 900 20/2 2#12,#12G.,3/4"C. A 2#12,#12G.,314"C. 20/1 200 TIME CLOCK/TELEPHONE BOARD 26 27 BREAK ROOM REFRIG. 700 HACR - B 2#12,#12G.,3/4"C. 20/1 800 DRINKING FOUNTAIN 28 29 IBREAK ROOM MICROWAVE 1500 20/2 2#12,#12G.,3/4"C. C 2#12,#12G.,3/4"C. 20/1 1500 PLUG MOLD AT COUNTER 30 31 BREAK RM RECEPT. 1500 HACR - A 2#101013.,3/4"C. 30/2 1238 ICEE MACHINE 32 33 TELEVISIONS 720 20/1 2#12,#12G.,3/4"C. B - 1238 - 34 35 TELEVISIONS 720 20/1 2#12,#12G.,314"C• C 2#12,#12G.,3/4"C. 20/1 720 CONVIENCE RECEPTACLES 36 37 TELEVISIONS 720 20/1 2#12,#12G.,3/4"C. A 2#12,#12G.,3/4"C. 20/1 800 OFFICE RECEPT 38 39 MAINT. RECEPT. 800 15/1 2#12,#12G.,3/4"C. B 2#12,#12G.,3/4"C. 20/1 1000 CONVIENCE RECEPTACLES 40 41 EF -1 667 15/1 2#12,#12G.,3/4"C. C 2#12,#12G.,3/4"C. 20/1 1000 ICONVIENCE RECEPTACLES 42 NOTES: 1 PROVIDE BOLT ON BREAKERS 2 PROVIDE TYPED PANEL DIRECTORY LOAD SUMMARY CONN NEC DEM LOAD BALANCE PER PHASE ® 1 -LIGHTING 2400 1.25 3000 PHASE A 12058 2 -RECEPTACLES 24760 NEC 17380 PHASE B 11698 3 -KITCHEN 2476 0.65 1609.4 PHASE C 11867 4 -HVAC 4600 1 4600 LOWEST PHASE PLUS 10% 0 5 -NON -CONT 1387 1 1387 11698 + 10% 12868 LARGEST MOTOR 0 0.25 0 PHASES ARE BALANCED Q}+ TOTAL VA 35623 27976 TOTAL AMPS 98.9 77.7 ® GROUNDING NOTE: VERIFY EXISTING SYSTEM IS GROUNDED PER N.E.C. ART. 250. UPGRADE AS REQUIRED. CONNECT NEW SYSTEM TO EXISTING GROUND. ELE DETAIL DESCRIPTION ® FLUORESCENT FIXTURE ® FIXTURE ON NIGHT LIGHT OR EMERG. CIR �+ WALL MOUNTED EXIT LIGHT (SOLID II` CEILING MOUNTED EXIT LIGHT (SOLID Q+ WALL MOUNTED INCANDESCENT FIXTUF 0 CEILING MOUNTED INCANDESCENT FIXI 4C::p EMERGENCY BATTERY PACK Q}+ WALL MOUNTED JUNCTION BOX ® CEILING MOUNTED JUNCTION BOX WALL MOUNTED DUPLEX RECEPTACLE O FLOOR MOUNTED DUPLEX RECEPTACLE WALL MOUNTED SINGLE RECEPTACLE B FLOOR MOUNTED SINGLE RECEPTACLE ®+ SPECIAL RECEPTACLE ® SPECIAL RECEPTACLE WALL MOUNTED QUADRUPLEX RECEPTo ® FLOOR MOUNTED QUADRUPLEX RECEP' ABOVE COUNTER RECEPTACLE $ SINGLE POLE SWITCH $ P PILOT LIGHT SWITCH $ T SINGLE THROW THERMAL SWITCH $ M MOTOR RATED SWITCH BUZZER CCI BELL PUSHBUTTON (MOMENTARY) MOTOR o TELEPHONE BACKBOARD v TELEPHONE OUTLET FLOOR MOUNTED TELEPHONE OUTLET Q POS CONNECTION FLOOR MOUNTED POS CONNECTION v COMBINATION DATA AND PHONE JACK 0 FLOOR MOUNTED COMBINATION DATA NOTE: NOT ALL SYMBOLS MAY APPEAR ON DRAWINGS. ALL CONDUCTORS SHALL BE COPPER GROUNDING NOTE: VERIFY EXISTING SYSTEM IS GROUNDED PER N.E.C. ART. 250. UPGRADE AS REQUIRED. CONNECT NEW SYSTEM TO EXISTING GROUND. EX 2 SETS OF 3#600,#1 /OG., IN w11n /%irnrrv\ �-. --- --__ r- %j znw /n 11 ., / •�•/ rLIC rvr_t, urr_mA IIVNAL ANU AUt.WUA ItLT (VERIFY) SIZED PER MANUFACUTRER ELECTRICAL RISER DIAGRAM AND SCHEDULES NOT TO SCALE ARCHITECT phase zero design 35 POND PARK ROAD, BAY 16 HINGHAM, MA 02043 PHONE: (781) 452-7121 FAX: (781) 875-3039 www.phasezerodesign.com Cfl111:011 JUMP 2018 LLC 10108 EVERGREEN LANE DRIVE TAMPA, FL 33647 PHONE: (813) 838-8896 ELECTRICAL ENGINEER DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 1 1 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 FLORIDA ENGINEER NO. 0051096 (MECH) MECHANICAL & PLUMBING ENGINEER IDSTUD104 1431 GREENWAY DRIVE IRVING, TX 75038 PHONE: (972) 870-1288 STRUCTURAL ENGINEER ZABIK TURNER ENGINEERING JENNIFER ZABIK, PE, SE 1024 N FULLERS CROSS ROAD WINTER GARDEN, FL 34787 PHONE: (407) 864-8120 0 Q O Q w Z EE 0 T_ CD V_ » 9 J LL 0 O LL Z Q /COMMENTS ISSUED FOR: PERMIT - BID ISSUED DATE: 04.04.2018 DRAWN BY: -- CHECKED BY: -- PROJECT NUMBER: 2118015 Copyright (c) by Phase Zero Design Corp. AN Rights Reserved, DRAWING NAME ELECTRICAL SCHEDULES & RISER DIAGRAM DRAWING NO. 11 E301