HomeMy WebLinkAbout301 White Cedar Rd (a)Is WALL TYPE LEGEND 1 IA INDICATES TILT -UP CONC WALL PANELS WITH 5/8' GYP 50 t FURRING( I In' STUDS i 24' OC W/ 11/2' BATT INSUL ON INSIDE. SEE STRUCTURAL. IA WALL IS TILT -UP CONC WITHOUT FURRMG. 2 WRATED 3 5/8' METAL STUD WALL WITH 5/8' GW5 ON 50TH SIDES TO A50VE LAY -N CEILING OR TO GWB CEILING 3 UNRATED W METAL STUD WALL WITH 5/8' GWB ON BOTH SIDES WALL TO DECK 4 UNRATED W METAL PLUMBING STUD WALL OATH 5/8' GWB ON 507H SIDES WALL TO ABOVE LAY -N CEILING OR TO GW5 CEILING. 5 ONE HOUR RATED W METAL STUD WALL WITH 5/8' TYPE X GM ON 50TH SIDES TO DECK b UNRATED LOW WALL, 48' HIGH, 3 5/8' METAL STUD WALL WITH 5/8' GWB ON 50TH SIDES UNRATED LOW WALL, 60' HIGH, 3 5/8' METAL STUD WALL WITH 5/8' GWB ON BOTH SIDES V FINISH KEY ROOM NAME 101 ROOM 1 A i A NUMBER FLOO CEILING BASE WALLS NMI ROOM FINISH SCHEDULE NQF_-_-1 NORT14 rF- FL O,Q� gLA1V/AV—, O ? r � ,� O 2', AR00066271,', ,sTFRED ARG�`� FLOOR BASE WALLS CEILING 2'x2' ACOUSTICAL TILE - USG, 1 CONCRETE - SEALED A 4' VINYL 1 PAINT ON GWB A RADAR, BASIC, SHADOWLINE 0 3 3 .� O EDGE OR APPROVED EQUAL 2 PORCELAIN TILE 12'X12' CLASS A (OFOI) B 6' PORCELAIN TILE 2 PAINT ON Gm OR GONG B PAINT ON GM O N O 4'-0' WAINSCOT, 12'x12' PORCELAIN tt O V7 O 3 VCT - STATIC (OFOI) C 4' WOOD 3 TILE ON CEMENT BD, EPDXY PANT ON C EPDXY PAINT ON MR C*6 Gde A50VE 4 CARPET TILE, D NONE 4 NONE D NONE CLASS B (OFOI) o • w °E L 7 c.)8 M aa°'io� 5 LVT - VINYL PLANK, W O 3 E M 5 c o c E t rc 1` Ow CLASS 5 (OFOI) U° z N Nelson Blankenship, AIA 101 This item has been electronically signed and sealed by Nelson Blankenship, Jr. on the Date/Time stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the sig- nature must be verified on any electronic copies. NOTES I. OWNER TO APPROVE FINISHES AND COLORS BEFORE INSTALLATION. 2. CEILING GRID SHALL BE USG DONN 15/16 DX/DXL OFFICE REVISION PERMIT # /�„�, c k. 3 3 a 00 z z z tD toC: CL 0 3 3 .� O O Q O N O N O tt O V7 O �aaa ;z (n O M V to O (D Q IL m o • w °E L 7 c.)8 M aa°'io� w o " C Z O, O W O 3 E M c o c t rc 1` Ow W O Z U° z N Nelson Blankenship, AIA N V1 s A ;,4 s a�o [� = U N y 7u! x Z PQ 0 " Q � W U O �O O U "4 w OCd ` M U_ � F� DRAWN CHECKED RSC NBB PROJECT NUMBER 1722.1 DRAWING NUMBER A=101 DATE 09-26-18 4r.�' z z z 0 CL U U 0 O D1 O� 01 N 4 O N N O N O O O c>r_aaa 00 o FAq �o M cn Vm O 10 Q) a m 0 N g a WU C Z HO K C K W O O S w U N Nelson Blankenship, AIA a V1Ae a,;o F-+ w O W m w ~ z Q w U o �w o w °0w �con z � z W DRAWN CHECKED RSC NBB PROJECT NUMBER 1722.1 DRAWING NUMBER A-102 DATE 09-26-18 OF),'Cj This item has been electronically signed � LA and sealed by Nelson Blankenship, Jr. on 1'x4' SURFACE MOUNTED LED the Date/Time stamp shown using a digital 0� signature. 'JW MECHANICAL Printed copies of this document are not AR000considered signed and sealed and the sig - EXHAUST GRILLE - SEE must be verified on any electronic ED copies. CEILING LEGEND PROTTEECTI�ONR/ EECTTRCI AAL DRAIU�S) ACOUSTICAL TILE LAY -IN 1'x4' SURFACE MOUNTED LED SUPPLY GRILLE -SEE CEILING - SEE FINISH SCHEDULE ® LIGHT FIXTURE - SEE ELECTRICAL MECHANICAL o RECESSED LED DOIINLIGT EXHAUST GRILLE - SEE GYPSUM UJALL BOARD CEILING - FIXTURE - SEE ELECTRICAL 1-4 MECHANICAL SEE FINISH SCHEDULE �_o WALL SCONCE - SEE ELECTRICAL OCCUPANCY SENSOR - SEE ELECTRICAL 2'x4' RECESSED LED LIGHT FIXTURE SEE ELECTRICAL m EXIT LIGHT - SEE ELECTRICAL 10'-0' CEILING HEIGHT - rn rn FIRE SPRINKLER HEAD NOTES: � N 1. SPRINKLER HEADS IN SPACES OPEN TO CUSTOMERS SHALL BE CONCEALED WITH COVER PLATE IN COLOR TO MATCH CEILING FINISH. 2. SPRINKLER HEADS IN SPACES IN BACK OF HOUSE NOT VISIBLE TO CUSTOMERS SHALL BESTANDARD SURFACE MOUNTED CHROME. O 3. HEADS IN SHOUJROOM SUSPENDED CLOUD MUST BE ALIGNED UJITH LIGHTING FIXTURES. �aaa 4. HEADS IN ACOUSTICAL TILE MUST BE CENTERED. m z z z 0 0 1-4 o O O U 1-. � rn rn (U � N � O O O �aaa S 9J 0 Q t Q Q d 0' Q vfn i Q) C O � V ID y o IL m e o E E v n a 1_1_I U�p O J W >?'� E o ; •C � l� !n V J 3 O 7 s U z N Nelson Blankenship, AIA U e;8 Q � al w 444 H 4. w �� w �-i V M FF --civ T r�TT� DRAWN CHECKED DR NBB PROJECT NUMBER 1722.1 DRAWING NUMBER A-103 DATE 09-26-18 CLEAR GLASS SIZE, AS SIZE AS A B C ALUMINUM SC WOOD SC WOOD STOREFRONT OR HM OR HM SIZE AS HIM DOOR TYPES SCALE: 3/16" = 1'-0" SIZE AS SCHED E COILING STEEL SIZE AS SCHED F CLEAR VINYL DRAFT CURTAIN VERIFY 18'-4 3/4' FIELD VERIFY 4'-2 3/4' 1'-4' O I O DOOR FRAME TYPCS ' SCALE: 3/16" = 1'-0" A-601 /W5A-601 I = = 1 1 OI. 4'-0' 6'-0' 3'-0' j \ 1 'v ' �• J3 I a, e Al © B1 ALUMINUMO A-601 A5601 GLASS ��T• A 601 STOREFRONT WINDOW TYPES SCALE: 3/16" = F-0" TILT WALL GWB ON METAL STUDS SEE WALL TYPE 5/8 GWO t FURRING MASONRY = — — — JAMB ANCHOR FRAME (3) PER JAMB SEALANT CONT = MIN EA SIDE 3 0 5 4 HM FRAME 0 — TYPE MAT. FINISH 0 U �, b 0 H1 - 101A PR 3'-0' X 1'-0' ALUM/GL ANOD A ALUM ANOD -- -- H3 J3 51 -- 101A PROX CARD ACCE55 1015 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 -- HI J1 -- -- 1015 102A 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT i -- HI J1 -- -- 102A co 1025 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT i � -- Hl J1 -- -- 1025 102C PR -3'-O' X 1'-0' 5C WOOD STAIN LL11 HM PAINT I U° -- Hl J1 O I O DOOR FRAME TYPCS ' SCALE: 3/16" = 1'-0" A-601 /W5A-601 I = = 1 1 OI. 4'-0' 6'-0' 3'-0' j \ 1 'v ' �• J3 I a, e Al © B1 ALUMINUMO A-601 A5601 GLASS ��T• A 601 STOREFRONT WINDOW TYPES SCALE: 3/16" = F-0" TILT WALL GWB ON METAL STUDS SEE WALL TYPE 5/8 GWO t FURRING MASONRY = — — — JAMB ANCHOR FRAME (3) PER JAMB SEALANT CONT = MIN EA SIDE 3 0 5 4 HM FRAME 0 — TYPE MAT. FINISH 0 U �, b 0 H1 - H2 J2 DOOR DETAILS SCALE: 1 1/2" = 1'-0" TILT WALL 5/8 GWD E FURRING 5/8' GWB ; 1 5/8' FURRING H3 J3 0 SIZE AS G a a H6 ETCHED LOGO A-601 a COORDINATE WITH OWNER 1 4'-0' i o IN ERIOR GL S ALL CONT EA SIDE e r � I iYl I ALUMINUM64 A -6 o 01 STOREFRONt DOOR / GLAZING DETAILS SCALE: 3" = 1'-0" a DOOR SCHEDULE DOOR TO HAVE KEYPAD LOCK PASSWORD DOOR N0. DOOR FRAME FIRE RATING DETAILS HDWE SET DOOR N0. NOTES SIZE MAT. FINISH TYPE MAT. FINISH TYPE U �, b HEAD JAMB SILL 101A PR 3'-0' X 1'-0' ALUM/GL ANOD A ALUM ANOD -- -- H3 J3 51 -- 101A PROX CARD ACCE55 1015 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 -- HI J1 -- -- 1015 102A 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT i -- HI J1 -- -- 102A co 1025 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT i � -- Hl J1 -- -- 1025 102C PR -3'-O' X 1'-0' 5C WOOD STAIN C HM PAINT I U° -- Hl J1 -- -- 102C Z�Pig Pp�C� z 103 Y-0' X 1'-0' SC WOOD STAIN 5 HM PAINT I -- Hl Ji -- -- 103 Q 0 104 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT I W -- NI 11 -- -- 104 105 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 XTnTl PROJECT NUMBER -- Hl 11 -- -- 105 106 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT i -- Hl 11 -- -- 106 101A 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 -- Hl J1 -- -- 101A 1015 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 -- Hl 11 -- -- 1015 108 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT I -- Hl 11 -- -- 108 109A 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT I -- Hl J1 -- -- 109A 1095 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT 1 -- Hl A -- -- 1095 110 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 -- H1 11 -- -- 110 111A 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT 1 -- HI J1 -- -- 111A 1115 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT 1 -- HI 11 1115 112 3'-0' X 1'-0' HM PAINT 5 HM PAINT 1 -- H2 J2 51 -- 112 GALV DOOR 4 FRAME PROX CARD ACCESS 113 3'-0' X 1'-0' Sc WOOD STAIN 5 HM PAINT 1 -- HI J1 -- -- 113 114 PR -2'-6' X 1'-0' SC WOOD STAIN C HM PAINT 1 -- N1 J1 -- -- 114 WEATHER PROOF GASKET 115 115 116 116 111 111 118 118 119 119 120 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 -- HI JI -- -- 120 121.1 31-01 X 11-01 ALUM/GL ANOD G ALUM ANOD D - - H3 J3 - - - - 121.1 1212 31-01 X 11-0# ALUM/GL ANOD G ALUM ANOD D - - H3 J3 - - - - 1212 1213 31-01 X 11-01 ALUM/GL ANOD G ALUM ANOD D - - H3 J3 - - - - 1213 122 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT 1 -- HI J1 -- -- 122 124 PR -3'-0' X 1'-0' SC WOOD STAIN C HM PAINT -- -- Hl J1 -- -- 124 WEATHER PROOF GASKET 125 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT 1 -- HI JI -- -- 125 126 3'-0' X 1'-0' HM PAINT 5 HM PAINT 1 -- H2 J2 Sl -- 126 GALV DOOR 4 FRAME PROX CARD ACCESS 121 3'-0' X 1'-0' 5C WOOD STAIN 5 HM PAINT 1 -- HI J1 -- -- 121 128 3'-0' X 1'-0' HM PAINT 5 HM PAINT 1 -- H2 J2 51 -- 128 GALV DOOR 4 FRAME 129 PR 3'-0' X 1'-0' SC WOOD STAIN C HM PAINT 1 -- H1 J1 -- -- 129 130 PR -2'-0' X 1'-0' SC WOOD PAINT C -- PAINT I -- Hl 11 -- -- 130 WEATHER PROOF GASKET 131 Y-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 -- Hl J1 -- -- 131 132A PR 3'-0' X 1'-0' 5C WOOD STAIN C HM PAINT 1 -- Hl J1 -- -- 132A 1325 PR 3'-0' X 1'-0' HM PAINT C HM PAINT I 60 MIN Hl A 51 -- 1325 WEATHER PROOF GASKET 133 3'-0' X 1'-0' SC WOOD STAIN 5 HM PAINT 1 -- Hl J1 -- -- 133 134 3'-0' X 1'-0' HM PAINT 5 HM PAINT 1 60 MIN NI 11 -- -- 134 135 3'-0' X 1'-0' HM PAINT 5 HM PAINT 1 60 MIN H1 11 -- -- 135 136 9'-0' X 1'-0' WOOD PAINT D -- PAINT 1 -- -- -- -- -- 136 51 -FOLD 131A 3'-0' X 1'-0' HM PAINT 5 HM PAINT 1 -- H2 J2 51 -- 131A GALV DOOR 4 FRAME PROX CARD ACCESS 1315 PR 3'-0' X 1'-0' HM PAINT C HM PAINT I -- H2 J2 -- -- 1315 1310 Y-0' X 1'-0' HM PAINT 5 HM PAINT 1 -- H1 J1 -- -- 131C 131D 10'-0' X 10'-0' VINYL CLEAR F -- -- -- -- -- -- -- -- 131D CASED OPENING 131E 10'-0' X 10'-0' VINYL CLEAR F -- -- -- -- -- -- -- -- 131E CASED OPENING 131.1 3'-0' X 1'-0' HM PAINT 5 HM PAINT I -- H2 J2 51 -- 131.1 GALV DOOR 4 FRAME 1'-0' HM PAINT 5 HM PAINT 1 -- Hl 11 Sl -- 138 WEATHER PROOF GASKET 139 DOOR DELETED 139 - - HM PAINT 5 HM PAINT 1 -- H2 J2 Sl -- 140A GALV DOOR E FRAMEPROX CARD ACCESS 1405 3'-0' X 1'-0' HM PAINT 5 HM PAINT 1 -- H2 J2 Sl -- 1405 GALV DOOR 4 FRAME PROX CARD ACCESS 140C 16'-0' X 10'-0' STEEL FACTORY E -- -- -- -- -- -- -- -- 140C STEEL COILING DOOR NOTES I. EXCEPT AS SPECIFICALLY PERMITTED 5Y SECTION 1008.1.8, EGRESS DOORS SHALL 5E READILY OPENA5LE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL EFFORT. 2. KEYING TO 5E DETERMINED 5Y OWNER. 3. HARDWARE OPERATION SHALL 5E PER OWNER'S REQUIREMENTS AND COMPLY WITH F5C AND NFPA 101. 4, HARDWARE SHALL 5E LEVER TYPE HANDLES, ADA COMPLIANT 4 MATCH OWNER'S REQUIREMENTS, SEE SPECIFICATIONS. 5. ALL INTERIOR GLASS SHALL 5E CLEAR UNLE55 NOTED OTHERWISE (UNO). 6. ALL DOORS NEED TO 5E SOFT CLOSE. DOOR t FRAME AS SCHEDULED O F Ft O This item has been electronically signed ADA COMPLIANT ALUM . - - -' THRESHOLD SET IN BED g�PQ� $`ANkF2.9 the Date/Time stamp shown using a digital - — OF SEALANT $10 �5, signature. `-' Printed copies of this document are not S2 �.2 ��� `, AR0006627 G considered signed and sealed and the sig- r''iS; nature must be verified on any electronic FRED ARG copies. m z z z Cbj) 0 to L U �, b U b o, o, C, cz 0 0 0 co 14 U) � b b d � � � g c U M LCL, CT d 'o+ o {�7 J O o �+J U t U) & � O W o Z S U° 2 � Nelson Blankenship, AIA a�� N qM� x �z v A 9 W �Oowwa wA Z�Pig Pp�C� z �Q�� �1 V a a � �° F �o ►-a H Q 0 i o U Z W � o V O O DRAWN CHECKED XTnTl PROJECT NUMBER 1722.1 DRAWING NUMBER A-601 DATE 09-26-18 Q m � o N U N 0 O CZ Mo 0 � 2.1 t!'1 O r= i ... .... ...... _.......... _. ......._.__ ....._. __ ...._.•a: :.r �: _�—:._.�._....�� •. .� fir=M::�• :�� �...•_ - \� -:. �µ--.�::::�:.:.: µ_a :: _ __ — - - ,... ., .�. _.. a I -, Q 0 LA, ]D } ZONE 2 "OT 11 --- ZONE 1 ��� 0£ } } Ik I?= l I ■■ -- ZONE 5 yy[,I Ilaoo} _- fl ZONE� I e I 3-3 ZONE_ T3-2 I pp ZONE 6 T 0 0, 1 ONE _ 0 � ZONE T`` l� 7L) _ ______ Nelson Blankenship, AIA �. 0 f } a _!� , I I1 I g BIZ O N E 7 1 ZONE 8 18, j T/1 e $ L I � ■ Ti PQ 0-1C j 0 -s`e o <S�� 3 =` C �.r s■■■ CH 0 C C ZONE 4 - I, I - dI I l } } ii IV .. .. .. .......... ..._......... .....ac.:.:... .,.tea.., a�' ....._t.. .n .. ::i.: ....... ............ ,#., a ysY.�..^,-emw.es., d. `.... i Q O � w C w U o 0 N �' w w MECHANICAL ZONE MAP O SCALE: 1/8" = V-0" W r-� o DRAWN CHECKED re\ -- C E N4-:C�I/,p�i� PROJECT NUMBER • 4 / 1722.1 :' .o o o ;�: No. 31932 :�'�: CONSULTING ENGINEERS DRAWING NUMBER - • • - STRUCTURAL MECHANICAL ( ELECTRICAL 4 PLUMBINGFIRE PROTECTION LU U, 7T X m R BERT D WENPOR .E. • 7j . www.rgdengineers.com FLORIDA P.E. NO.31 2 M 1 0 1 o STATE OF ���; MADE IN THE USA MECHANICAL ENGINEER ��,,�s ••�� OR' �Ps ��''.' 4901 VINELAND RD #335, ORLANDO, FL 32811 (407) 845-6630 CERT OF AUTH 5454 •••^u•• signature<�'�. Thee Drawings are NOT VALID for any purpose which requires the original DATE 5.6.2019 unless ,,•80,,,16ISS0,6 rawing and notsea] sg ed and sealed the sealedrby thetengneerr shall notsignature benubmtted toany affixed. DATE p y authority or used for any purpose where signed and sealed documents are required. 10.18-18 1 1 M-202 M-204 f iw� 07 (D(Di ikoo 1W t o @ills j _. m_. _.... ...._ Li 777 j I .,. Il� 1 x i Y£ lyffl Nil lo I TF 7 7 J, III t, I t 1. w I a MCA lk `. �m� S �'s'•r �w_.e..� { ? ®� , .. � �:aFi'a:x�,- +.. �.s ::.X: s.�..a...7 ts..._:_.. _ aY. a. -x _ ...- - _ _ - - _ x .. �c = �.+� i.A 0 'j 3 3 U i ,£ 4 Pill 1 } r{ ,I — I 709 rrrml; € y 111111111111k:N1 tI t 1 \ awl t { . Iw i y; 31 rN �j j_�.. t i- _ {I{ .... .... �. �, .;•s :. ,..y�o-wey em wo-o-w.w�-v-r ��„ � -- wo r> a_x ._ '..?fJT`yr .? .:�€....s..�w�.si'�u`3.✓i'�'°.�."=S'?.a,..c€.�%.. �$.�s... _.""�..�e'�" _�.�" _ _ } I W t £ f � � I 1 1 M-203 M-205 MECHANICAL FLOOR PLAN 1 r SCALE: 1/8" = V-0" G, DA r#.* �����: • �' E `S'F ' ' OoCL .� No. 31932 CONSULTING ENGINEERS • • .0 STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING FIRE PROTECTION D,': ROBERT DAVENPO P.E. • • www.rgdengineers.com FLORIDA P.E. NO. 31932 Q :• STATE OF •:��� MADE IN THE USA MECHANICAL ENGINEER �•'•� Q •' \`'ii 4901 VINELAND RD #335, ORLANDO, FL 32811 (407) 845-6630 CERT OF AUTH 5454 �(1 • oP. "s%'•NORI ••`��.i These Drawings are NOT VALID for any purpose signature requires the original DATE 5.6.2019 �NAless**�. Drawings notnature and seal of signed andesg ledrbyy the nless tengi engineer original hallnnot be submitted to affixed. authority or used for any purpose where signed and sealed documents are required. m Q 04 a—,o U W d �y U`�" Z� a v� w c o � 0 n 40 Z x $ wz 0- U) U N U W� o� 2 0 0 w z N CO O� I O E N O a� cc Nelson Blankenship, AIA QIrAA0 a—,o U W d �y U`�" Z� a v� w U o � 0 n 40 Z x $ wz Q U U W� o� 2 w DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-201 DATE 10-18-18 as W 0 v� w U o 0 0�-4 r3 yy Q U U W� o� 2 w w z O DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-201 DATE 10-18-18 A m P4 c � o 'C U N � N 0 D1 N ' N p 0 ' O N C cti CL 0 r— C7 t} Q Nelson Blankenship, AIA W a U ar z� H� Hwy �0-4 2� wA C z x WW1 W¢� U < ¢ate a��o � � Q elf O 0 vs w U o �w z Lu r3 i� U w Lu z M w DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-202 DATE 10-18-18 m Q � c � o C N U (Z D O ' O LLL FM C ftp CL O C 'wy b l.J Nelson Blankenship, AIA a '- 's �. lm fuy ® u�N V z n x U O MSU a��o Z FD al W • ^ "- �, v� W U o a s-, a L'� b U U �4LU w W o W O z M � w DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-203 DATE 10-18-18 ENLARGED MECHANICAL FLOOR PLAN # MECHANICAL KEY NOTES: 1. 12X12 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM OF EACH AR -HANDLING UNIT: 10"0 TO AHU-5,8"0 TO AHU-6A, 8"0 TO AHU-613. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 2. 10"0 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM OF EACH AIR -HANDLING UNIT: 8"0 TO AHU-3, 10"0 TO AHU-4. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 3. 8"0 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM On EACH AIR -HANDLING UNIT: 6"0 TO AHU-1, 8"0 TO AHU-2. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 4. PROVIDE 24X24 NOA-APPROVED WIND -DRIVEN RAIN RESISTANT LOUVER EQUAL TO RUSKIN EME6325D (NOA# 15-7031.07, FLPA #FL 14156.1). INSTALL PER NOA INSTALLATION INSTRUCTIONS. 5. INSTALL 6" HOUSEKEEPING PAD. COORDINATE DIMENSIONS WITH SITE, EQUIPMENT DIMENSIONS, AND EQUIPMENT CLEARANCES. 6. PROVIDE GREENHECK MODEL BR -30 BAROMETRIC RELIEF DAMPER. SET TO OPEN @ 0.05" wg. 7. PROVIDE RELIEF DAMPER FOR AHU-3 ZONE DAMPER BYPASS/DUMP ZONE. SCALE: 1/4" = V-0" c o � � vi a z� ° N b F-� ►� G O 0 C'3 tz 0 O J O Cc U U0 Z Nelson Blankenship, AIA a vi0 V In . o a// � vi a z� ° U x k� � as b F-� ►� G O 0 C'3 O CHECKED I PROJECT NUMBER 1722.1 DRAWING NUMBER M-204 DATE 10-18-18 z z b g O C'3 O J rrI�� \.J U U0 Z (404 LU Q w 0 o Lu WO Z Z W u CHECKED I PROJECT NUMBER 1722.1 DRAWING NUMBER M-204 DATE 10-18-18 4 �3\ S 400 CFM F. C!) MECHANICAL KEY NOTES: 1. 12X12 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM OF EACH AIR -HANDLING UNIT: 10"0 TO AHU-5,8"O TO AHU-6A, 8"0 TO AHU-66. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 2. 10"0 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM OF EACH AIR -HANDLING UNIT: 8"0 TO AHU-3, 10"0 TO AHU-4. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 3. 8"0 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM OF EACH AIR -HANDLING UNIT: 6"0 TO AHU-1, 8"0 TO AHU-2. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 4. PROVIDE 24X24 NOA-APPROVED WIND -DRIVEN RAIN RESISTANT LOUVER EQUAL TO RUSKIN EME6325D (NOA# 15-7031.07, FLPA #FL 14150.1). INSTALL PER NOA INSTALLATION INSTRUCTIONS. 5. INSTALL 6" HOUSEKEEPING PAD. COORDINATE DIMENSIONS WITH SITE, EQUIPMENT DIMENSIONS, AND EQUIPMENT CLEARANCES. 6. PROVIDE GREENHECK MODEL BR -30 BAROMETRIC RELIEF DAMPER. SET TO OPEN @ 0.05" wg. 7. PROVIDE RELIEF DAMPER FOR AHU-3 ZONE DAMPER BYPASS/DUMP ZONE. SCALE: 1/4" = V-0" CO lu O � Q 'C 1" i o O 180 r� 180 i E cz 1 1O^ V I (D YW Il C O • V VVV0VVVIIIIII C7 Nelson Blankenship, AIA arA a w,�1.e a U O uMNr "j } x O H S w Q C IFA1�/ o a� U a 1IIY----1111 cdJ 1 a - O ^...-.+ O w U c 00 033 E I 3 Lu 0 V1 Lu W o z M � w U DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-205 DATE 10-18-18 180 I i .: I 0' 1 I 180 I f t •_ (�y �1' 8 14x14 :12x12 Ap TG -1 -6B ------------- i,a .N— HU I TG -1 - � 110 SD- 165 € '� F SD -1 190 2 t i 1 SD -1 190 I � ?, 3 I i3jij$7a I i3 1 DD 139 '1 J SD -1 I j ( SD -1 190 I I E I I E i SD 't'.P, 165 e e 175 �3\ S 400 CFM F. C!) MECHANICAL KEY NOTES: 1. 12X12 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM OF EACH AIR -HANDLING UNIT: 10"0 TO AHU-5,8"O TO AHU-6A, 8"0 TO AHU-66. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 2. 10"0 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM OF EACH AIR -HANDLING UNIT: 8"0 TO AHU-3, 10"0 TO AHU-4. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 3. 8"0 OUTDOOR DUCT DOWN TO MECHANICAL CLOSET. BRANCHES FROM OUTDOOR AIR DUCT SHALL TAP INTO THE RETURN AIR PLENUM OF EACH AIR -HANDLING UNIT: 6"0 TO AHU-1, 8"0 TO AHU-2. EACH CONNECTION SHALL HAVE A MANUAL VOLUME DAMPER FOR BALANCING AND A MOTORIZED DAMPER SET TO CLOSE WHILE THE AHU IS OFF. 4. PROVIDE 24X24 NOA-APPROVED WIND -DRIVEN RAIN RESISTANT LOUVER EQUAL TO RUSKIN EME6325D (NOA# 15-7031.07, FLPA #FL 14150.1). INSTALL PER NOA INSTALLATION INSTRUCTIONS. 5. INSTALL 6" HOUSEKEEPING PAD. COORDINATE DIMENSIONS WITH SITE, EQUIPMENT DIMENSIONS, AND EQUIPMENT CLEARANCES. 6. PROVIDE GREENHECK MODEL BR -30 BAROMETRIC RELIEF DAMPER. SET TO OPEN @ 0.05" wg. 7. PROVIDE RELIEF DAMPER FOR AHU-3 ZONE DAMPER BYPASS/DUMP ZONE. SCALE: 1/4" = V-0" CO Q O � Q 'C 1" o O r� cz 1O^ V I (D YW Il C O V VVV0VVVIIIIII C7 Nelson Blankenship, AIA arA a w,�1.e a U O uMNr x x O H S w Q C IFA1�/ o a� U a 1IIY----1111 cdJ O Q a - O -- c's (� w -,:5 ; �LL.vi O w U c "d 3� U z `� c3 Lu 0 V1 Lu W o z M � w U DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-205 DATE 10-18-18 Id MECHANICAL FLOOR PLAN SCALE: 1/8"= V-0" ammom Nelson Blankenship, AIA � 7 � A P-� e Z W a Hwy w 0-4 w C1 C zx�� W¢�9 � 7 � A P-� Z: �D al w LL. v1 w U o 0 � Q U U W 0 03wLu U z U c) DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER DATE 10-18-18 MECHANICAL ISOMETRIC PLAN GLOBAL REVISIONS TO SHEET: ISOMETRIC PLAN UPDATED TO MATCH FLOOR PLAN REVISIONS. FAI N.T.S. Nelson Blankenship, AIA a vl ~' o w-1 o N U U P N M r v z O H Q .gyp w Q C z�WQc U V w PROJECT NUMBER 1722.1 DRAWING NUMBER M-301 DATE 10-18-18 Q O �D W .� E2 w J W 0 Q W PROJECT NUMBER 1722.1 DRAWING NUMBER M-301 DATE 10-18-18 3 3 G . DA��., •�� Q�� '•GEN •'' . �/�•. 0*0 No. 31932 16�'_ CONSULTING ENGINEERS • • STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING I FIRE PROTECTION X: ROBERT DAVENPORTP.E. �; www.rgdengineers.com FLORIDA P.E. NO. 31932 STATE OF 10 0 �;��� MADE 1N THE USA MECHANICAL ENGINEER ��1 �'•• �� QP •� �`# 4901 VINELAND RD #335, ORLANDO, FL 32811 (407) 845-6630 CERT OF AUTH 5454 "n • OR � � rr i •N•.p.••• *00 These Drawings are NOT VALID for any purpose which requires the original DATE 5.6.2019 ��,,�NA;,,{{`{', Drawings rnot nd ss signed andea] of the sealed bydthe ess teng neer hall inal nnot beature asubmitted seal are to y authority or used for any purpose where signed and sealed documents are required. STEM SCHEDU UNIT NO. AHU/CU-1 AHU/CU-2 AHU/CU-3 AHU/CU-4 AHU/CU-5 AHU/CU-6A � AHU/CU-6B AHU/CU-8 NOM. TONS 2.0 4.0 2.5 4.0 5.0 4.0 ! 3.0 5.0 SEER 15.0 14.5 14.5 14.5 14.0 14.5 14.5 14.0 MANUF. TRANE TRANE TRANE TRANE TRANE TRANE ! TRANE TRANE MODEL #CONDENSER 4TTR4024L1 4TTR4048L1 4TTR4030L1 4TTR4048L1 4TTR4060L1 4TTR4048L1 � 4TTR4036L1 4TTR4060L1 MODEL #AIR HANDLER TEM4A0B24 TEM4AOC48S41 TEM4AOB30S31 TEM4AOC48S41 TEM4AOC60S51 TEM4AOC48S41 TEM4AOC36S41 TEM4AOC60S51 DESIGN CFM (NOTE 2) 720 1665. 1000 1400 2000 1440 � 1075 1995 OUTDOOR AIR CFM 85 120 145 230 305 210 ! 160 165 DESIGN M.B.U.T.H. T.C. 19.1 41.6 25.5 35.9 53.6 36.7 i 27.6 51.0 @75/63° F S.C. 16.6 39.1 18.7 30.9 36.5 33.5 ! 25.1 44.8 DB (°F) 74.8 74.9 82.8 74.7 79.1 74.7 ! 74.7 74.8 ENTERING TEMPERATURE WB (°F) 61.0 59.9 66.7 61.1 65.8 60.3 60.3 60.7 DB (°F) 53.8 53.8 53.8 53.8 53.8 53.8 53.8 53.8 LEAVING TEMPERATURE WB (°F) 51.6 51.0 52.3 51.6 52.8 51.2 ! 51.2 51.3 QTY 1 1 1 1 1 1 1 1 COMPRESSOR RLAlLRA (EA) 10.9/63 18.5/124 12.8/68 18.5/124 23.7/152.5 18.5/124 14.1 / 72 23.7/152.5 QTY COND. FAN FLA/LRA 0.6/- 1.05/- 0.64/- 1.051- 1.05/- 1.05/- 0.64/- 1.05/ - HP 1/15 1/5 1/8 1/5 1/5 1/5 1/8 1/5 MCA 14 24 17 24 31 24 ; 17 31 BR. CIR. AMPACITY - CU MOCP 25 40 25 40 50 40 25 50 DIMENSIONS (INCHES) W X D X H / # 26.7 X 30 X 30.1 / 133 35.1 X 38.7 X 34.4 / 189 30.1 X 33 X 38 / 156 35.1 X 38.7 X 34.4 / 189 35.1 X 38.7 X 42.4 / 211 35.1 X 38.7 X 34.4 / 189 � 30.1 X 33 X 34 / 156 35.1 X 38.7 X 42.4 / 211 V 208 208 208 208 208 208- ' 208 208 CONDENSER POWER PH 1 1 HZ 60 60 60 60 60 60 i 60 60 SUCT. 3/4 7/8 3/4 7/8 7/8 7/8 3/4 7/8 REF. LINE SIZE O.D. LIQ. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 FLA/HP 1.3/1/4 6.3/3/4 2.5/1/2 6.3/3/4 6.3/3/4 6.3/3/4 ! 2.6/1/2 6.3/3/4 AIR HANDLER V 208 208 208 208 208 208 208 208 FAN MOTOR pH 1 1 1 1 1 1 ! 1 1 HZ 60 60 60 60 60 60 60 60 HEATER (@ 208V) KW 5.76 7.2 + 3.6 (2 CIRCUITS) 5.76 7.2 + 3.6 (2 CIRCUITS) 7.2 + 3.6 (2 CIRCUITS) 7.2 + 3.6 (2 CIRCUITS) 7.2 7.2 + 3.6 (2 CIRCUITS) MCA 36 51 +22 38 51 +22 51 +22 51 +22 47 51 +22 BR. CIR. AMPACITY -AHU MOCP 40 60+25 40 60+25 60+25 60+25 50 60+25 DIMENSIONS (IN) WXDxH/# 18.5 X21.5 X45.5/110 23.5 X21.5 X51.5/138. 18.5 X21.5 X45.5/110 23.5 X21.5 X51.5/138 23.5 X21.5 X51.5/138 23.5 X21.5 X51.5/138 j 23.5 X21.5 X51.5/138 23.5 X21.5 X51.5/138 NOTES: 14 1-4 1� 1-4 1-4 1-4 14 14 NOTES: 3 1. UNITS SHALL BE PROVIDED WITH ELECTRIC HEAT W/ CIRCUIT BREAKER AS SPECIFIED. 2. CONSULT MANUFACTURER DOCS TO SET EQUIPMENT TO MEET AIRFLOW REQUIREMENTS AS SHOWN. 3. UNITS SHALL BE PROVIDED WITH OUTDOOR AIR AS SCHEDULED. 4. PROVIDE WITH RETURN AIR FILTER RACK. 5. UNIT SHALL BE USED WITH HONEYWELL ZONE DAMPER SYSTEM. (OR EQUAL). REFERENCE HONEYWELL DOCUMENTATION FOR MORE INFORMATION. APPROVED ALTERNATE VENTILATION CALCULATIONS (BASED ON FBCM 5TH EDITION TABLE 403.3) SCHEDULE OCCUPANCY CATEGORY SQ FT SF/P P CFM/P CFM/SF CFM (P) CFM (AREA) TOTAL CFM NOTES Classrooms (Age 9+) 554 29 19 10 0.12 97 66 163 1 Conference Rooms 414 20 21 5 0.06 52 25 77 1 Office Spaces 10437 200 52 5 0.06 261 626 887 NOTE 2 Main Entry Lobbies 383 100 4 5 0.06 19 23 42 OMNI -AA Corridors 517 0 0 0 0.06 0 31 31 NOTE 2 Toilet Rooms (Public) 663 0 0 0 0 0 0 0 Storage Rooms 299 0 0 0 0.12 0 36 36 RG -1 TITUS Warehouses 5710 0 0 0 0.06 0 343 343 N/A 1,2,3 N TOTAL CFM REQUIRED: 1579 TOTAL CFM PROVIDED: 1820 CIL NOTES: FOR ALL CATEGORIES: OCCUPANCY CATEGORY AND DENSITY FROM TABLE 403.3 FBCM 5TH EDITION. 1. A DIVERSITY FACTOR OF 0.5 HAS BEEN APPLIED TO THE OCCUPANCY LOAD CFM(P) BASED ON FBCM 5TH EDITION, SECTION 403.3.2.3.3. - IT IS ASSUMED THAT THE AVERAGE SYSTEM POPULATION IS APPROXIMATELY HALF OF THE SUM OF THE MAXIMUM FOR THE CATEGORIES WHERE THIS DIVERSITY FACTOR HAS BEEN APPLIED. O TG -2 TITUS 350FL 12" X 12" - FIXED SURFACE NOTE 1 NOTE 2 N/A 1,2,3 x � UM vPPi v 02 V p v e Z� n ZZ � wz EX -1 TITUS 350FL 12" X 12" - FIXED SURFACE NOTE 1 NOTE 2 N/A 1,2,3 SPECIAL NOTES: ALL DIFFUSERS SELECTED WITH NC RATING < 20 " 1. COORDINATE COLOR WITH ARCHITECT 2. PROVIDE VOLUME DAMPER AT THE FLEX TAP. PROVIDE YOUNG REGULATOR FOR VOLUME DAMPERS IN INACCESSIBLE AREAS. 3. PROVIDE TITUS RAPID MOUNT FRAME FOR STANDARD 24" x 24" LAY -IN STYLE DIFFUSERS MOUNTED IN HARD CEILINGS. &FOR ALL 12" X 12" SUPPLY DIFFUSERS -REGARDLESS OF THE MOUNTING LOCATION. 4. PROVIDE OPTIONAL R-6 MOLDED INSULATION BLANKET FOR ALL LAY -IN STYLE DIFFUSERS. APPROVED ALTERNATES: PRIG NAILOR, TUTTLE:x BAILEY. KRUEGER ZD in WN �--• w U 0 Q rz � w W � o DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-401 DATE 10-18-18 MANUFACTURERS: CARRIER, YORK 3 3 G . DA��., •�� Q�� '•GEN •'' . �/�•. 0*0 No. 31932 16�'_ CONSULTING ENGINEERS • • STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING I FIRE PROTECTION X: ROBERT DAVENPORTP.E. �; www.rgdengineers.com FLORIDA P.E. NO. 31932 STATE OF 10 0 �;��� MADE 1N THE USA MECHANICAL ENGINEER ��1 �'•• �� QP •� �`# 4901 VINELAND RD #335, ORLANDO, FL 32811 (407) 845-6630 CERT OF AUTH 5454 "n • OR � � rr i •N•.p.••• *00 These Drawings are NOT VALID for any purpose which requires the original DATE 5.6.2019 ��,,�NA;,,{{`{', Drawings rnot nd ss signed andea] of the sealed bydthe ess teng neer hall inal nnot beature asubmitted seal are to y authority or used for any purpose where signed and sealed documents are required. STEM SCHEDU UNIT NO. AHU/CU-1 AHU/CU-2 AHU/CU-3 AHU/CU-4 AHU/CU-5 AHU/CU-6A � AHU/CU-6B AHU/CU-8 NOM. TONS 2.0 4.0 2.5 4.0 5.0 4.0 ! 3.0 5.0 SEER 15.0 14.5 14.5 14.5 14.0 14.5 14.5 14.0 MANUF. TRANE TRANE TRANE TRANE TRANE TRANE ! TRANE TRANE MODEL #CONDENSER 4TTR4024L1 4TTR4048L1 4TTR4030L1 4TTR4048L1 4TTR4060L1 4TTR4048L1 � 4TTR4036L1 4TTR4060L1 MODEL #AIR HANDLER TEM4A0B24 TEM4AOC48S41 TEM4AOB30S31 TEM4AOC48S41 TEM4AOC60S51 TEM4AOC48S41 TEM4AOC36S41 TEM4AOC60S51 DESIGN CFM (NOTE 2) 720 1665. 1000 1400 2000 1440 � 1075 1995 OUTDOOR AIR CFM 85 120 145 230 305 210 ! 160 165 DESIGN M.B.U.T.H. T.C. 19.1 41.6 25.5 35.9 53.6 36.7 i 27.6 51.0 @75/63° F S.C. 16.6 39.1 18.7 30.9 36.5 33.5 ! 25.1 44.8 DB (°F) 74.8 74.9 82.8 74.7 79.1 74.7 ! 74.7 74.8 ENTERING TEMPERATURE WB (°F) 61.0 59.9 66.7 61.1 65.8 60.3 60.3 60.7 DB (°F) 53.8 53.8 53.8 53.8 53.8 53.8 53.8 53.8 LEAVING TEMPERATURE WB (°F) 51.6 51.0 52.3 51.6 52.8 51.2 ! 51.2 51.3 QTY 1 1 1 1 1 1 1 1 COMPRESSOR RLAlLRA (EA) 10.9/63 18.5/124 12.8/68 18.5/124 23.7/152.5 18.5/124 14.1 / 72 23.7/152.5 QTY COND. FAN FLA/LRA 0.6/- 1.05/- 0.64/- 1.051- 1.05/- 1.05/- 0.64/- 1.05/ - HP 1/15 1/5 1/8 1/5 1/5 1/5 1/8 1/5 MCA 14 24 17 24 31 24 ; 17 31 BR. CIR. AMPACITY - CU MOCP 25 40 25 40 50 40 25 50 DIMENSIONS (INCHES) W X D X H / # 26.7 X 30 X 30.1 / 133 35.1 X 38.7 X 34.4 / 189 30.1 X 33 X 38 / 156 35.1 X 38.7 X 34.4 / 189 35.1 X 38.7 X 42.4 / 211 35.1 X 38.7 X 34.4 / 189 � 30.1 X 33 X 34 / 156 35.1 X 38.7 X 42.4 / 211 V 208 208 208 208 208 208- ' 208 208 CONDENSER POWER PH 1 1 HZ 60 60 60 60 60 60 i 60 60 SUCT. 3/4 7/8 3/4 7/8 7/8 7/8 3/4 7/8 REF. LINE SIZE O.D. LIQ. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 FLA/HP 1.3/1/4 6.3/3/4 2.5/1/2 6.3/3/4 6.3/3/4 6.3/3/4 ! 2.6/1/2 6.3/3/4 AIR HANDLER V 208 208 208 208 208 208 208 208 FAN MOTOR pH 1 1 1 1 1 1 ! 1 1 HZ 60 60 60 60 60 60 60 60 HEATER (@ 208V) KW 5.76 7.2 + 3.6 (2 CIRCUITS) 5.76 7.2 + 3.6 (2 CIRCUITS) 7.2 + 3.6 (2 CIRCUITS) 7.2 + 3.6 (2 CIRCUITS) 7.2 7.2 + 3.6 (2 CIRCUITS) MCA 36 51 +22 38 51 +22 51 +22 51 +22 47 51 +22 BR. CIR. AMPACITY -AHU MOCP 40 60+25 40 60+25 60+25 60+25 50 60+25 DIMENSIONS (IN) WXDxH/# 18.5 X21.5 X45.5/110 23.5 X21.5 X51.5/138. 18.5 X21.5 X45.5/110 23.5 X21.5 X51.5/138 23.5 X21.5 X51.5/138 23.5 X21.5 X51.5/138 j 23.5 X21.5 X51.5/138 23.5 X21.5 X51.5/138 NOTES: 14 1-4 1� 1-4 1-4 1-4 14 14 NOTES: 3 1. UNITS SHALL BE PROVIDED WITH ELECTRIC HEAT W/ CIRCUIT BREAKER AS SPECIFIED. 2. CONSULT MANUFACTURER DOCS TO SET EQUIPMENT TO MEET AIRFLOW REQUIREMENTS AS SHOWN. 3. UNITS SHALL BE PROVIDED WITH OUTDOOR AIR AS SCHEDULED. 4. PROVIDE WITH RETURN AIR FILTER RACK. 5. UNIT SHALL BE USED WITH HONEYWELL ZONE DAMPER SYSTEM. (OR EQUAL). REFERENCE HONEYWELL DOCUMENTATION FOR MORE INFORMATION. APPROVED ALTERNATE AIR VENTILATION CALCULATIONS (BASED ON FBCM 5TH EDITION TABLE 403.3) SCHEDULE OCCUPANCY CATEGORY SQ FT SF/P P CFM/P CFM/SF CFM (P) CFM (AREA) TOTAL CFM NOTES Classrooms (Age 9+) 554 29 19 10 0.12 97 66 163 1 Conference Rooms 414 20 21 5 0.06 52 25 77 1 Office Spaces 10437 200 52 5 0.06 261 626 887 NOTE 2 Main Entry Lobbies 383 100 4 5 0.06 19 23 42 OMNI -AA Corridors 517 0 0 0 0.06 0 31 31 NOTE 2 Toilet Rooms (Public) 663 0 0 0 0 0 0 0 Storage Rooms 299 0 0 0 0.12 0 36 36 RG -1 TITUS Warehouses 5710 0 0 0 0.06 0 343 343 N/A 1,2,3 N TOTAL CFM REQUIRED: 1579 TOTAL CFM PROVIDED: 1820 CIL NOTES: FOR ALL CATEGORIES: OCCUPANCY CATEGORY AND DENSITY FROM TABLE 403.3 FBCM 5TH EDITION. 1. A DIVERSITY FACTOR OF 0.5 HAS BEEN APPLIED TO THE OCCUPANCY LOAD CFM(P) BASED ON FBCM 5TH EDITION, SECTION 403.3.2.3.3. - IT IS ASSUMED THAT THE AVERAGE SYSTEM POPULATION IS APPROXIMATELY HALF OF THE SUM OF THE MAXIMUM FOR THE CATEGORIES WHERE THIS DIVERSITY FACTOR HAS BEEN APPLIED. O AIR BALANCE SCHEDULE EXHAUST/ RELIEF OUTSIDE AIR / MAKEUP AIR MANUF. TOTAL AHUs 1-8 0 1420 FINISH VOLUME DAMPER -1 590 0 RELIEF AIR 770 0 EF -2 400 0 MAKEUP AIR 0 400 BUILDING TOTALS: 1760 1820 LAY -IN 60 m GRILLE, REGISTER, &DIFFUSER SCHEDULE MARK MANUF. MODEL NO. NECK SIZE / FACE SIZE LENGTH THROW ! SLOTS FRAME TYPE FINISH VOLUME DAMPER FIRE DAMPER NOTES SD -1 TITUS OMNI -AA 24"X24" PER PLANS PER PLANS LAY -IN NOTE 1 NOTE 2 N/A 1,2,3,4 SD -2 TITUS OMNI -AA 12" X 12" PER PLANS PER PLANS LAY -IN NOTE 1 NOTE 2 N/A 1,2,3 rn � I o RG -1 TITUS 350FL 24"X24" - FIXED LAY -IN NOTE 1 NOTE 2 N/A 1,2,3 N c CIL O TG -2 TITUS 350FL 12" X 12" - FIXED SURFACE NOTE 1 NOTE 2 N/A 1,2,3 x � UM vPPi v 02 V p v e Z� n ZZ � wz EX -1 TITUS 350FL 12" X 12" - FIXED SURFACE NOTE 1 NOTE 2 N/A 1,2,3 SPECIAL NOTES: ALL DIFFUSERS SELECTED WITH NC RATING < 20 " 1. COORDINATE COLOR WITH ARCHITECT 2. PROVIDE VOLUME DAMPER AT THE FLEX TAP. PROVIDE YOUNG REGULATOR FOR VOLUME DAMPERS IN INACCESSIBLE AREAS. 3. PROVIDE TITUS RAPID MOUNT FRAME FOR STANDARD 24" x 24" LAY -IN STYLE DIFFUSERS MOUNTED IN HARD CEILINGS. &FOR ALL 12" X 12" SUPPLY DIFFUSERS -REGARDLESS OF THE MOUNTING LOCATION. 4. PROVIDE OPTIONAL R-6 MOLDED INSULATION BLANKET FOR ALL LAY -IN STYLE DIFFUSERS. APPROVED ALTERNATES: PRIG NAILOR, TUTTLE:x BAILEY. KRUEGER m Q � c O � � _ '0Cz U N � O rn � I o 0 N c CIL O i Nelson Blankenship, AIA x � UM vPPi v 02 V p v e Z� n ZZ � wz �o M c� Q � w ZD in WN �--• w U 0 Q rz � w W � o DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-401 DATE 10-18-18 FAN SCHEDULE MARK EF -1 EF -2 DUCT SIZE PER PLANS PER PLANS MOUNTING SIDEWALL SIDEWALL MANUFACTURER GREENHECK GREENHECK MODEL NUMBER CW -090 -VG CW -080 -VG ESP IN. WG. 0.5 0.3 AIRFLOW CFM 590 400 RPM 1648 1669 MOTOR INFORMATION MTR SIZE (HP) 1/10 1/10 OPER. HP 0.1 0.06 V 115 115 PH 1 1 Hz 60 60 NOTES: N 0 1,2,3,4 1,2,3,4 NOTES: 1. PROVIDE WITH BACKDRAFT DAMPER. 2. PROVIDE WITH SPEED CONTROLLER. 3. PROVIDE WITH TIME CLOCK CONTROL. FAN SHALL RUN DURING OCCUPIED HOURS. 4. PROVIDE ON/OFF STATUS OUTPUT TO CONTROL SYSTEM. APPROVED ALTERNATES: NUTONE, FANTECH tA C c WA cd CL C) O ,no Nelson Blankenship, AIA a V1 ® a�� o M h U H � � V1 � U � ;L O Fay a. pp H zx� W¢ c Cd LI..I C� � Q �n W U o "' = r3 i„i U w W � o z U M DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-402 DATE 10-18-18 PROPER INSTALLATION. 5. REFRIGERANT PIPING SHALL BE INS +ALLED FROM BACK OF UNIT CONCEALED IN WALL BEHIND UNIT. THERE SHALL BE NO EXPOSED PIPING. 6. PROVIDE WITH MANUFACTURER'S OPTIONAL CONDENSATE PUMP (SAUERMANN S130-115/230; 115/230V) APPROVED ALTERNATES: PANASONIC, DAIKIN FAN SCHEDULE MARK EF -1 EF -2 DUCT SIZE PER PLANS PER PLANS MOUNTING SIDEWALL SIDEWALL MANUFACTURER GREENHECK GREENHECK MODEL NUMBER CW -090 -VG CW -080 -VG ESP IN. WG. 0.5 0.3 AIRFLOW CFM 590 400 RPM 1648 1669 MOTOR INFORMATION MTR SIZE (HP) 1/10 1/10 OPER. HP 0.1 0.06 V 115 115 PH 1 1 Hz 60 60 NOTES: N 0 1,2,3,4 1,2,3,4 NOTES: 1. PROVIDE WITH BACKDRAFT DAMPER. 2. PROVIDE WITH SPEED CONTROLLER. 3. PROVIDE WITH TIME CLOCK CONTROL. FAN SHALL RUN DURING OCCUPIED HOURS. 4. PROVIDE ON/OFF STATUS OUTPUT TO CONTROL SYSTEM. APPROVED ALTERNATES: NUTONE, FANTECH A '��•��t�\•� C E N$�. ��p�i. • ••• O� No. 31932 RGD •:�'� CONSULTING ENGINEERS / • STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING I FIRE PROTECTION X ROBERT DAVENPORT P.E. i ?3. . • www.rgdengincers.com FLORIDA P.E. NO. 31932 j O . STATE OF . MADE 1N THE USA .��C/ MECHANICAL ENGINEER s• A� OR' �P ••(•'��_'�� 4901 VINELAND RD #335, ORLANDO, FL 32811 (407) 845-6630 CERT OF AUTH 5454 Itis/ •••NN•pp•••••!�`� � These Drawings are NOT VALID for any purpose which requires the original DATE 5.6.2019 •,,061122 ��••• Drawings notsignature and ssgned aeal of nd sealedrby the unless the original ashall not besignature n submitted td seal are o any authority or used for any purpose where signed and sealed documents are required. MINI SPLIT SYSTEM SCHEDULE UNIT NUMBER AHU J CU-7CIO NOMINAL TONS 2.0 SEER 21.4 MANUFACTURER MITSUBISHI MODEL #CONDENSER PUY-A24NHA7 MODEL #INDOOR UNIT PKA-A24KA7 DESIGN AIRFLOW (CFM) 800 DESIGN MBTU/H T.C. 24 @75/63° F S.C. 19.2 ENTERING DB (OF) 75.0 TEMPERATURE WB (°F) 63.0 LEAVING TEMPERATURE DB (°F) 55.0 WB (°F) 53.0 COMPRESSOR RLA /LRA 7/11 CONDENSER FAN FLA 0.4 CIRCUIT BREAKER MCA 19 AMPACITY MOCP 26 OD DIMENSIONS W X D X H > # 37.5 X 14.5 X 37.5 / 151 (IN /LBS) V 208 CONDENSER POWER PH 1 HZ 60 REF. LINE SIZE O.D. SUCT. 5/8 LIQ. 3/8 AIR HANDLER FAN FLA 0.36 MOTOR V DC 24 ID DIMENSIONS WXDXH/# 46.5 X12 X14.5/46 (IN /LBS) HEAT MBTU!H COOLING ONLY NOTES: 1-6 NOTES: 1. ALTERNATE EQUIPMENT SHALL BE EQUAL TO THE EQUIPMENT LISTED IN ALL RESPECTS. 2. ELECTRICAL SPECIFICATIONS LISTED ARE CONSISTENT WITH THE EQUIPMENT LISTED. ALTERNATE EQUIPMENT MAY VARY. COORDINATE VARIANCES WITH THE ELECTRICAL CONTRACTOR. 3. CONSULT MANUFACTURER DOCUMENTATION TO SET EQUIPMENT TO MEET AIRFLOW REQUIREMENTS LISTED. 4. ADDITIONAL REFRIGERANT MAYBE REQUIRED WHERE PIPE LENGTHS EXCEED 70 FT. REFER TO MANUFACTURER DOCUMENTATION FOR m c O 0A >~ bcc }• cd O N 0 � C tA C c WA cd CL C) O ,no Nelson Blankenship, AIA a V1 ® a�� o M h U H � � V1 � U � ;L O Fay a. pp H zx� W¢ c Cd LI..I C� � Q �n W U o "' = r3 i„i U w W � o z U M DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER M-402 DATE 10-18-18 ■ ELECTRICAL NOTES 1. THE CONTRACT DOCUMENTS CONSIST OF DRAWINGS, SPECIFICATIONS AND DESIGN INFORMATION PREPARED BY MULTIPLE DISCIPLINES AND MUST BE USED AS A WHOLE AND IN COORDINATION WITH EACH OTHER. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY APPARENT DISCREPANCIES OR OMISSION OF INFORMATION NOT SHOWN ON THE ELECTRICAL DRAWINGS. SHOP DRAWINGS SHALL BE PROVIDED WHERE NECESSARY FOR COORDINATION. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTING ERRORS RESULTING FROM LACK OF COORDINATION OF DOCUMENTS. 2. REFER TO THE ARCHITECTURAL DOCUMENTS FOR ALL APPLICABLE CODES. THE WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRICAL CODE (NFPA 70), FLORIDA BUILDING CODE 6TH EDITION (2017), 2013 NFPA 72, FLORIDA FIRE PREVENTION CODE 6TH EDITION, FAC, AND ANY OTHER LOCAL JURISDICTIONAL REQUIREMENTS. IN ADDITION, ANY BASE BUILDING OR TENANT GENERAL CONDITIONS SHALL GOVERN ACCEPTABLE MATERIALS AND WORK. 3. THE CONTRACTOR SHALL BRING ANY CONFLICTS OR DISCREPANCIES TO THE ATTENTION OF THE ENGINEER IN WRITING PRIOR TO PROCEEDING WITH WORK. 4. THE CONTRACTOR SHALL FIELD VISIT THE SITE PRIOR TO BID TO FAMILIARIZE HIMSELF WITH THE SCOPE OF WORK. 5. ALL WORK SHALL BE DONE IN A FIRST CLASS WORKMANLIKE MANNER BY A LICENSED ELECTRICAL CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE, CLEANLY, AND UNDISRUPTIVE JOB SITE THAT DOES NOT IMPEDE EGRESS PATHS OR OTHER TENANTS. DISRUPTIONS TO POWER AFFECTING OTHER TENANTS OR AREAS OUTSIDE THE SCOPE OF WORK SHALL BE COORDINATED WITH THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF HIS WORK. WHEN THE WORK IS COMPLETE, ALL ELECTRICAL DEVICES SHALL BE VACUUMED CLEAN. THE FINAL PRODUCT SHALL BE A FULLY FUNCTIONAL SYSTEM MEETING THE INTENT OF THE DRAWINGS/DOCUMENTS. WORKMANSHIP AND ALL MATERIALS AND EQUIPMENT SHALL BE GUARANTEED FOR A MINIMUM OF ONE YEAR IN WRITING COMMENCING UPON ACCEPTANCE OF INSTALLATION BY OWNER. 6. WITHIN 30 DAYS AFTER THE DATE OF THE SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING A SINGLE -LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. ADDITIONALLY, AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER INCLUDING THE FOLLOWING: SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE INCLUDING CLEARLY IDENTIFIED ROUTINE MAINTENANCE ACTIONS, AND NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. 7. UNLESS PROVIDED WITH DIMENSIONS OR NOTED OTHERWISE, ELECTRICAL PLANS ARE STRICTLY DIAGRAMMATIC ONLY. REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, MOUNTING HEIGHTS, ETC. EFFORT HAS BEEN MADE TO PROPERLY ACCOUNT FOR ALL SPACE REQUIREMENTS, CLEARANCES, ETC. BUT SITE CONDITIONS AND PRODUCTS SELECTED MAY VARY AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN PROPER ARRANGEMENTS AND CLEARANCES. DRAWINGS SHALL NOT BE SCALED. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS, PAYING ALL ASSOCIATED FEES, AND DOCUMENTING AND FILING ALL PAPERWORK ASSOCIATED WITH THIS SCOPE OF WORK. WHEN THE WORK IS COMPLETE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED CERTIFICATES OF INSPECTION. 9. UNLESS NOTED OTHERWISE ALL EXISTING ELECTRICAL DEVICES INSTALLED UNDER PREVIOUS CONTRACTS SHALL REMAIN. CONTRACTOR SHALL EXTEND AND RELOCATE EXISTING DEVICES INTO NEW TENANT SPACE AND MOUNT TO PARTITIONS, CEILINGS, OR FINISHES AS REQUIRED. 10. THE CONTRACTOR IS EXPECTED TO HAVE A FULL FUNCTIONAL KNOWLEDGE OF ELECTRICAL SYSTEMS AND WHETHER INDICATED ON THE DRAWINGS OR NOT SHALL PROVIDE THE CORRECT NUMBER OF WIRES, AT NO ADDITIONAL CHARGE, TO FACILITATE PROPER OPERATION OF ALL EQUIPMENT. QUANTITY OF WIRES WILL ONLY BE INDICATED WHERE NECESSARY FOR CLARIFICATION. 11. THE INSTALLATION SHALL BE IN COMPLIANCE WITH THE AMERICAN WITH DISABILITIES ACT (ADA), UNLESS INSTALLED FOR SPECIFIC USES EXEMPT FROM ADA OR IN AREAS NOT NORMALLY ACCESSED BY BUILDING OCCUPANTS. 12. THE ELECTRICAL CONTRACTOR SHALL REFER TO THE MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATIONS OF EQUIPMENT. PRIOR TO ORDERING ELECTRICAL EQUIPMENT SERVING MECHANICAL & PLUMBING EQUIPMENT, THE ELECTRICAL CONTRACTOR SHALL CONFIRM THE EQUIPMENT BEING ORDERED BY THE HVAC OR PLUMBING CONTRACTORS AND PROVIDE WIRING, CONDUIT, AND OVERCURRENT PROTECTION MEETING THE REQUIREMENTS AT NO ADDITIONAL COST. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING AND COORDINATING WITH THE HVAC CONTRACTOR FOR PROVIDING ANY NECESSARY LINE AND LOW VOLTAGE WIRING. FINAL TERMINATION TO BE MADE BY THE HVAC CONTRACTOR. ALL BREAKERS SUPPLYING HVAC LOADS SHALL BE HACR TYPE. 13. ALL EXISTING CIRCUITS INDICATED AS SPARE SHALL BE TRACED AND VERIFIED BY THE CONTRACTOR. IF A CIRCUIT IS LABELED AS SPARE OR INDICATED FOR RE -USE BUT UTILIZED BY AN ADJACENT TENANT OR OCCUPIED SPACE, THE ENGINEER SHALL BE NOTIFIED AND A NEW CIRCUIT SHALL BE ASSIGNED. 14. ALL MATERIALS AND EQUIPMENT FURNISHED SHALL BE NEW (UNLESS NOTED OTHERWISE) AND BEAR THE U.L. LISTING FOR THEIR INTENDED USE. MATCH BUILDING STANDARDS FOR MANUFACTURER AND TYPE OF EQUIPMENT FOR LIGHTS, EXIT SIGNS, FIRE ALARM DEVICES, WIRING DEVICES, AND ELECTRICAL DISTRIBUTION EQUIPMENT. WHERE NO BUILDING STANDARD EXISTS FOR ELECTRICAL EQUIPMENT, EQUIPMENT SHALL BE MANUFACTURED BY G.E., SQUARE -D, EATON CUTLER -HAMMER OR SIEMENS. INSTALL A PLASTIC -LAMINATE SIGN ON EACH NEW UNIT OF ELECTRICAL EQUIPMENT WITH 1/2" ENGRAVED LETTERING FOR IDENTIFICATION. IDENTIFICATION SHALL MATCH CONTRACT DOCUMENTS, SHALL INDICATE SOURCE FED PER NEC 408.4(8), AND SHALL INDICATE ARC -FLASH HAZARD PER NEC 110.16. 15. THE CONTRACTOR SHALL GIVE PERMISSION FOR THE AHJ, ENGINEER, ARCHITECT, INSPECTOR, ETC. TO PERFORM TESTS OF THE ELECTRICAL SYSTEM AS REQUIRED. 16. SWITCH OUTLETS SHALL NOT BE OBSTRUCTED BY DOORSWINGS AND OCCUPANCY SENSORS SHALL HAVE FULL VIEW OF THE INTENDED SPACE. 17. SWITCH AND RECEPTACLES INDICATED IN THE SAME LOCATION SHALL BE MOUNTED UNDER A COMMON COVERPLATE UNLESS OTHERWISE NOTED. 18. EVEN IF THE PLANS INDICATE, OUTLETS SHALL NOT BE INSTALLED PRECISELY BACK TO BACK ON COMMON WALLS. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT MOUNTING METHODS AND LOCATIONS. 19. JUNCTION AND PULL BOXES ARE ONLY INDICATED WHERE REQUIRED FOR LARGE SCALE COORDINATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING JUNCTION AND PULL BOXES AS REQUIRED BY THE CODE AND PER A STANDARD INSTALLATION, AND SHALL INCLUDE THIS IN THEIR BID. BOXES SHALL BE STEEL AND INCLUDE EARS INSIDE TO ATTACH COVERS. OUTLET BOXES SHALL BE FOUR INCH SQUARE DEEP TYPE. OUTLET BOXES FOR 120V OR HIGHER CIRCUITS SHALL INCLUDE A #12 AWG SOLID COPPER PIGTAIL. OUTLET BOXES LOCATED OUTDOOR OR EXPOSED TO WET CONDITIONS SHALL INCLUDE GASKETED COVERS. THE MAXIMUM GAP AROUND BOXES SHALL BE 1/8" OR SMALLER ON ALL EDGES. JUNCTION BOXES SHALL BE COLOR CODED WITH PAINT TO INDICATE THEIR USE AS FOLLOWS: NORMAL POWER - BLACK, STANDBY POWER - ORANGE, FIRE ALARM - RED, TELEPHONE/DATA - YELLOW, HVAC CONTROLS - BLUE. 20. CONDUCTORS SHALL BE LOOPED AROUND SCREW POSTS SO THAT ROTATION OF THE SCREW TENDS TO FURTHER WRAP THE CONNECTION. SCREW TERMINALS SHALL BE WRAPPED IN ELECTRICAL TAPE. AT LEAST 6" OF FREE CONDUCTOR SHALL BE LEFT AT EACH J -BOX, OUTLET AND SWITCH BACK -BOX, ETC FOR FUTURE SPLICING. 21. THE CONTRACTOR SHALL MAINTAIN THE FIRE RATING OF ALL FIRE -RATED PARTITIONS, AS INDICATED IN IEEE RED BOOK IF A DEVICE WILL VOID THE FIRE RATING OF A WALL, IT SHALL BE INSTALLED IN AN ALTERNATE LOCATION PER THE ARCHITECT OR ENGINEER'S DIRECTION. ALL VOIDS AROUND CONDUITS AND/OR CORE DRILLS PENETRATING FIRE RATED PARTITIONS SHALL BE FILLED WITH FIRE-SAFING MATERIAL OR UL APPROVED FIRE RATING DEVICE. THE FIRE RATING OF A PARTITION SHALL NEVER BE COMPROMISED. ELECTRICAL NOTES 22. THE CONTRACTOR SHALL MAINTAIN THE INSULATION RATING AND VAPOR BARRIERS ON ALL PERIMETER WALLS. IF A DEVICE WILL DAMAGE OR COMPROMISE THE VAPOR BARRIER OR INSULATION, IT SHALL BE INSTALLED IN AN ALTERNATE LOCATION PER THE ARCHITECT OR ENGINEER'S DIRECTION. 23. ALL EQUIPMENT REQUIRING ACCESS SUCH AS J -BOXES, PULL BOXES, TRANSFORMERS, DRIVERS, ETC. SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS. EXISTING ELECTRICAL DEVICES WHICH ARE LOCATED BEHIND INACCESSIBLE LOCATIONS DUE TO THE RENOVATION SHALL BE REROUTED AND MADE ACCESSIBLE. 24. CONDUITS AND/OR MATERIALS LOCATED IN ENVIRONMENTAL AIR PLENUMS SHALL BE PROPERLY LISTED FOR THE APPLICATION. INTERIOR CONCEALED RACEWAYS MAY BE AC OR MC CABLE IF ALLOWED BY THE AHJ. EXPOSED RACEWAYS, INCLUDING RACEWAYS EXPOSED IN THE BACK OF HOUSE SHALL BE GALVANIZED STEEL OR ALUMINUM EMT. MOTOR CONNECTIONS SHALL BE FLEXIBLE METAL CONDUIT FOR INTERIOR APPLICATIONS AND LIQUID TIGHT FLEX FOR EXTERIOR APPLICATIONS. ALL OTHER EXTERIOR CONDUITS SHALL BE GALVANIZED STEEL, ALUMINUM EMT OR RIGID STEEL IF EXPOSED TO STRIKING. EXTERIOR CONDUITS SHALL UTILIZE COMPRESSION CONNECTORS. AC/MC CABLE SHALL NOT TERMINATE AT PANELBOARDS. A GUTTER OUTSIDE THE ELECTRICAL CLOSET SHALL BE PROVIDED WITH CONDUIT FROM THE GUTTER TO THE PANELBOARD. 25. CABLE AND CONDUIT ROUTING SHALL BE DONE IN A NEAT AND ORDERLY FASHION. LINES SHALL BE RUN PARALLEL TO ALL BUILDING FEATURES, AND SHALL BE GROUPED TOGETHER TO CREATE AN AESTHETICALLY PLEASING AND EASY TO FOLLOW ROUTE. CABLES SHALL BE PERMITTED TO BE BUNDLED BUT SHALL NOT EXCEED TEN IN QUANTITY. ROUTING SHALL BE COORDINATED WITH OTHER TRADES TO AVOID CONFLICT. 26. CONDUITS SHALL BE RIGIDLY SUPPORTED TO THE BUILDING STRUCTURE. AC AND MC CABLES SHALL BE SUPPORTED WITHIN 12" OF EVERY BOX, FITTING, ETC. AND SUPPORT SPACINGS SHALL NOT EXCEED 6' INTERVALS. RIGID CONDUIT SUPPORT SPACINGS SHALL NOT EXCEED 10'-0' FOR VERTICAL RUNS AND 8'-0" FOR HORIZONTAL RUNS, HOWEVER ALL SUPPORT SPACINGS FOR ALL CONDUIT TYPES SHALL BE IN ACCORDANCE WITH THE NEC REGARDLESS OF WHAT IS STATED HERE. COUPLINGS AND FITTINGS SHALL BE STEEL WITH COMPRESSION OR SET STEEL SCREW CONNECTIONS. THERE SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL) BETWEEN PULL POINTS FOR POWER (120V OR HIGHER) CIRCUITS AND NOT MORE THAN THE EQUIVALENT OF TWO QUARTER BENDS (180 DEGREES TOTAL) BETWEEN PULL POINTS FOR LOW VOLTAGE (TELEPHONE, DATA, ETC) CIRCUITS. LOW VOLTAGE CONDUIT RUNS SHALL ALSO NOT EXCEED 100' BETWEEN PULL POINTS. ALL CONDUITS SHALL BE TERMINATED WITH INSULATED THROAT CONNECTORS FOR CONDUITS 1" AND SMALLER, AND WITH INSULATED BUSHINGS AND LOCKNUTS FOR CONDUITS OVER 1". EMPTY CONDUIT RUNS EXCEEDING 10' SHALL BE PROVIDED WITH PULL WIRES SECURELY FASTENED AT BOTH ENDS. EXPANSION FITTINGS SHALL BE PROVIDED AT ALL BUILDING EXPANSION JOINTS OR WHERE NEEDED TO ALLOW FOR THERMAL EXPANSION. 27. CONDUIT SIZES INDICATED IN PANEL SCHEDULES AND ON THE SINGLE LINE ARE BASED ON TYPE THHN IN EMT. AS OTHER TYPES OF CONDUIT AND CONDUCTORS ARE PERMISSIBLE IN THIS PROJECT, THE CONTRACTOR SHALL ADJUST THE DIMENSION OF THE CONDUIT TO COMPLY WITH CHAPTER 9, TABLE 1 IN THE NEC. ADJUSTMENTS TO THE CONDUIT SIZE SHALL BE PART OF THE BID AND SHALL BE AT NO ADDITIONAL EXPENSE TO THE OWNER. 28. WIRE SIZES INDICATED ARE BASED UPON DIRECT ORTHOGONAL PATHS TO THE PANELBOARD. FEEDERS ARE SIZED FOR A MAXIMUM OF 2% VOLTAGE DROP, AND BRANCH CIRCUITS ARE DESIGNED FOR A MAXIMUM OF 3% VOLTAGE DROP. IF FIELD CONDITIONS DO NOT ALLOW THESE PATHS OR IF THE CONTRACTOR RUNS ADDITIONAL LENGTHS, THEY SHALL BE RESPONSIBLE FOR INCREASING WIRE SIZE TO ACCOUNT FOR VOLTAGE DROP AT NO ADDITIONAL COST. WIRING SMALLER THAN #12 AWG SHALL NOT BE USED FOR ANY INSTALLATIONS. 29. THE CONTRACTOR SHALL CIRCUIT PANELBOARDS EXACTLY AS INDICATED IN THE PANEL SCHEDULES. IF ANY DEVIATIONS ARE NECESSARY, THE ENGINEER SHALL BE NOTIFIED. TYPED DIRECTORY CARDS SHALL BE PROVIDED AT EACH PANELBOARD INDICATING LOAD SERVED AND FINAL ROOM NUMBERS PER THE NEC. WHEN EXISTING DIRECTORIES ARE REPLACED FOR RENOVATION WORK, EXISTING LOAD INFORMATION SHALL BE DIRECTLY TRANSFERRED TO THE NEW DIRECTORY CARDS. 30. NEUTRAL CONDUCTORS SHALL ONLY BE SHARED WHEN INDICATED ON THE DRAWINGS. WHERE NEUTRALS ARE INDICATED TO BE SHARED, THE NEUTRAL SHALL BE A MINIMUM OF #10 AWG. 31. THE CONTRACTOR SHALL REMOVE ALL UNUSED AND ABANDONED WIRING AND CABLING FROM THE CEILING PLENUM THAT ISN'T LABELED FOR FUTURE USE, AS REQUIRED BY THE NEC. THIS SHALL INCLUDE BUT IS NOT LIMITED TO FIRE ALARM, POWER, SECURITY, CONTROLS, DATA, TELEPHONE, A/V, ETC. 32. ALL BRANCH CIRCUIT CONDUCTORS AND FEEDER CIRCUITS 100A OR SMALLER SHALL BE COPPER. FEEDER CIRCUITS SERVING LOADS LARGER THAN 100A MAYBE EITHER COPPER OR ALUMINUM, HOWEVER THE DESIGN IS BASED AROUND COPPER AND THE CONTRACTOR WILL BE RESPONSIBLE FOR ACCOUNTING FOR INCREASED WIRE SIZE, CONDUIT SIZE, AND SPACE TAKEN BY THE LARGER CONDUIT IF ALUMINUM IS USED. HOWEVER, BRANCH CIRCUITS FEEDING MOTORS SHALL ALWAYS BE COPPER REGARDLESS. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID, AND CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED. CONDUCTORS SHALL BE CODE TYPE THW, THHN, THWN, OR XHHW UNLESS OTHERWISE REQUIRED BY THE NEC. CONDUCTORS SHALL BE MARKED WITH INSULATION CODE, VOLTAGE RATING, AWG SIZE, AND MANUFACTURER AND INCLUDE A CONTINUOUS COLOR CODING FROM PANEL TO LOAD SERVED. WHERE CONTINUOUS MARKINGS ARE NOT AVAILABLE, USE COLOR CODED TAPE AT EACH TERMINATION. #8 AWG AND SMALLER CONDUCTORS SHALL BE SPLICED WITH SPRING CONNECTORS. #6 AWG AND LARGER SHALL BE SPLICED WITH BARREL CONNECTORS REQUIRING COMPRESSION ON EACH END. 33. ALL EMERGENCY EGRESS, STANDBY LIGHTING, AND EXIT LIGHTING SHALL HAVE A BATTERY BALLAST WITH RUN TIME MEETING OR EXCEEDING 90 MINUTES. THE BATTERY BALLAST SHALL NOT BE CAPABLE OF BEING DISCONNECTED. REGARDLESS OF MODEL NUMBER SPECIFIED, LIGHT FIXTURES SPECIFIED WITH BACKUP BATTERY BALLASTS SHALL HAVE THE TEST BUTTON INTEGRALLY MOUNTED WHERE POSSIBLE. WHERE FIXTURES ARE NOT AVAILABLE WITH INTEGRALLY MOUNTED TEST BUTTONS, THE TEST BUTTONS SHALL BE LOCATED IN A DISCRETE LOCATION AS DETERMINED BY THE ARCHITECT, UP TO 50' AWAY FROM THE FIXTURE. 34. THE EQUIPMENT GROUNDING SYSTEM SHALL CONSIST OF AN ELECTRICALLY CONTINUOUS METALLIC CONDUIT SYSTEM TOGETHER WITH INSULATED EQUIPMENT GROUNDING CONDUCTORS. EVERY ITEM SERVED BY THE ELECTRICAL SYSTEM SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH NEC ARTICLE 250. THIS SHALL INCLUDE RACEWAYS, JUNCTION/OUTLET BOXES, MACHINE FRAMES, ETC. ALL BRANCH CIRCUITS AND FEEDERS SHALL HAVE A GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR OR GROUND ELECTRODE SIZED IN ACCORDANCE WITH THE NEC. PROVIDE BONDING JUMPERS FOR ALL NON-CURRENT CARRYING CONDUCTORS OF DIFFERENT SYSTEMS TO ENSURE NO VOLTAGE POTENTIAL METAL GAS PIPING SHALL ONLY BE GROUNDED AT EQUIPMENT HOUSING BOTH ELECTRICAL CIRCUITS AND UTILIZING GAS VIA THE EQUIPMENT GROUND ROUTED WITH THE CIRCUIT. ALL GROUND WIRES SHALL BE COPPER. 35. SUBMITTALS SHALL BE SUBMITTED ELECTRONICALLY, IN PDF FORMAT. THE CONTRACTOR SHALL ALLOW FOR A TOTAL OF 10 BUSINESS DAYS FOR REVIEW BY THE ENGINEER. SUBMITTALS SHALL INCLUDE PANELBOARDS, TRANSFORMERS, DISCONNECTS, WIRING DEVICES, UPS'S, LIGHT FIXTURES, TVSS, AND FIRE ALARM SYSTEM. SUBMITTALS SHALL ONLY INCLUDE DATA RELEVANT TO THIS PROJECT; DATA SHEETS INDICATING SEVERAL PRODUCTS SHALL HAVE THE RELEVANT PRODUCTS HIGH-LITED OR CLEARLY IDENTIFIED. SIMILAR EQUIPMENT SHALL BE SUBMITTED IN ONE COMPLETE SUBMITTAL PACKAGE (I.E. ALL PANELBOARDS, ALL LIGHTING FIXTURES, ETC.). 36. DUPLEX OUTLETS SHALL BE NEMA 5-20R WHEN THEY ARE THE ONLY LOAD ON A CIRCUIT. 37. PROVIDE PHOTOELECTRIC TWIST IN TYPE SMOKE DETECTORS WITH ACCESS DOORS IN ALL FANS AND AHU'S SERVING A COMMON PLENUM OF 2000 CFM OR ABOVE. ALL SMOKE DETECTORS SHALL BE BY ONE MANUFACTURER, AND SHALL COMPLY WITH UL 268A. LOCATE THE SMOKE DETECTORS IN THE SUPPLY AIR DUCT FOR INSTALLATIONS IN COMPLIANCE WITH THE FLORIDA BUILDING CODE. THE DETECTORS SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR & INSTALLED IN THE DUCT BY THE MECHANICAL CONTRACTOR. ELECTRICAL CONNECTION SHALL BE BY ELECTRICAL CONTRACTOR. UPON SMOKE DETECTION, ALL ASSOCIATED AIR MOVING EQUIPMENT SERVING A COMMON PLENUM WILL BE SHUT DOWN. TIE FIRE ALARM DEVICES INTO EXISTING FIRE ALARM SYSTEM (IF APPLICABLE). 38. E.C. SHALL BE RESPONSIBLE FOR PROVIDING A JUNCTION BOX AND DIRECT ELECTRICAL CONNECTION TO EACH HVAC CONDENSATE PUMP AS NEEDED PER MECHANICAL DRAWINGS OR FIELD CONDITIONS. PROVIDE 2#12, 1#12G, IN 1/2"C FROM NEAREST 120V G.P. RECEPTACLE CIRCUIT. ELECTRICAL SYMBOL LEGEND SINGLE POLE, 20 AMP, SWITCH. $3 3 -WAY, 20 AMP, SWITCH. $4 4 -WAY, 20 AMP, SWITCH. DIMMER SWITCH. USE NTF-IG-WH FOR FLUORESCENT FIXTURES. USE NTFTV-WH WITH PP -120H FOR LED $D FIXTURES. CONFIRM COLOR SELECTION WITH ARCHITECT PRIOR TO ORDERING. $M SINGLE POLE, 20 AMP, SWITCH WITH OCCUPANCY SENSOR. $0# TIME -CLOCK OVERRIDE SWITCH. REFER TO LIGHTING CONTROL NOTES. $T SWITCH WITH THERMAL OVERLOAD PROTECTION (MANUAL MOTOR STARTER) CP 20 AMP SIMPLEX RECEPTACLE TT 20 AMP DUPLEX RECEPTACLE f20 AMP QUADRUPLEX RECEPTACLE ®x RECEPTACLE SUBSCRIPT DEFINITIONS: ff,, a: GFCI, WP, WR b: GFCI, WP, WR, TR c: GFCI, TR 20 AMP DUPLEX RECEPTACLE, TOP HALF SWITCHED. TT GFI 20 AMP DUPLEX RECEPTACLE, WITH SELF -TESTING GROUND FAULT CIRCUIT INTERRUPTER. TT IG 20 AMP DUPLEX RECEPTACLE WITH ISOLATED GROUND. r' ® WIREMOLD RFB4 20 AMP DUPLEX/QUADRUPLEX RECEPTACLE, RECESS FLOOR MOUNTED BOX. ® RA WIREMOLD RFB4 20 AMP DUPLEX/QUADRUPLEX RECEPTACLE WITH DATA/TELEPHONE, v RECESS FLOOR MOUNTED BOX. 20 AMP DUPLEX RECEPTACLE, CEILING MOUNTED. SPECIAL-PURPOSE RECEPTACLE; NEMA TYPE AS INDICATED. G JUNCTION BOX PB PULL BOX 0 TELEPHONE OUTLET WITH 3/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. v DATA OUTLET WITH 1" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. v TELEPHONE/DATA OUTLET WITH 1" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. TELEPHONEIDATA OUTLET FLOOR RECESSED. 0 TELEPHONE/DATA OUTLET CEILING MOUNTED. EMERGENCY LIGHT t FUSIBLE DISCONNECT SWITCH NFSS = NON FUSED, F30SS = FUSED J- GROUNDING ELECTRODE & CONDUCTOR SYSTEM DTRANSFORMER 120/208V ELECTRICAL PANELBOARD; MANDATORY CLEARANCE INDICATED WITH DASHED LINES. LI 277/480V ELECTRICAL PANELBOARD; MANDATORY CLEARANCE INDICATED WITH DASHED LINES. WIRE CONCEALED IN WALLS/CEILINGS. QUANTITY OF WIRES IN HOMERUN INDICATED ON PANEL SCHEDULES. GROUND WIRE IS IN ADDITION TO WIRES INDICATED. ADDITIONAL SWITCH WIRES SHALL BE DETERMINED BY E.0 / LOW VOLTAGE WIRE CONCEALED IN WALLS/CEILINGS. QUANTITY OF WIRES SHALL BE DETERMINED BY E.C. EXIT SIGN. SHADED SIDES INDICATE FACES. ARROWS INDICATE CHEVRONS. 4 SINGLE PHASE MOTOR THREE PHASE MOTOR NA INTEGRAL STARTER OR CONTROLLER AND DISCONNECT CABINET BY THE MECHANICAL CONTRACTOR E CIRCUIT BREAKER Ell MAGNETIC MOTOR STARTER AND DISCONNECT BY THE ELECTRICAL CONTRACTOR aM MAGNETIC MOTOR STARTER BY THE ELECTRICAL CONTRACTOR pT T -STAT BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR MVD MOTORIZED DAMPER BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL WIRE TO NEAREST G.P. RECEPTACLE CIRCUIT USING 2#12, 1#12 G. IN 1/2" CONDUIT. ® POWER PACK USED FOR 12 OR 24V DC OCCUPANCY SENSORS METER ® AUTOMATIC TRANSFER SWITCH MOLDED CASE CIRCUIT BREAKER ® PLUG-IN FUSED DISCONNECT G_> CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. ARROWS INDICATE DIRECTION OF COVERAGE. I CEILING -MOUNTED SPEAKER - IN AREAS OF INACCESSIBLE CEILING, PROVIDE JUNCTION BOX AND 3/4" CONDUIT NEAREST ACCESSIBLE CEILING. AP CEILING -MOUNTED WIRELESS ACCESS POINT - IN AREAS OF INACCESSIBLE CEILING, PROVIDE JUNCTION BOX AND 3/4" CONDUIT NEAREST ACCESSIBLE CEILING. ® RFID CARD READER WITH BUZZER. ® RFID CARD READER. ® PHOTO/DAYLIGHT SENSOR DUCT SMOKE DETECTOR NOTE: NOT ALL SYMBOLS MAY APPLY TO PLANS ELECTRICAL SHEET INDEX E-001 ELECTRICAL COVER SHEET E-002 ELECTRICAL SITE PLAN - E-101 ELECTRICAL POWER PLAN E-102 ELECTRICAL POWER PLAN- ROOF E-103 ELECTRICAL LOW VOLTAGE PLAN E-201 ELECTRICAL LIGHTING PLAN E-301 ELECTRICAL RISER & DETAILS E-302 ELECTRICAL SCHEDULES E-303 ELECTRICAL DETAILS E-304 ELECTRICAL DETAILS MFR RRGD� \� �' CEN F••• ,� *: " CONSULTING ENGINEERS STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING I FIRE PROTECTION j.�bl u►- www d em.com MICHAEL R. TRIPP % t- A FLORIDA P.E. NO.45407 � �� MADE IN THE USA ELECTRICAL ENGINEER STA OF P •� ?` 4901 VINELAND RD #33S, ORLANDO, FL 32811 (407) 845-6630 CERT OF AUTH 5454 jtYs • �•... R •I....'P 0.0 �\\* These Drawings are NOT VALID for any purpose which requires the original DATE 5.20.2019 O �\ signature and seal of the engineer unless the original signature and seal are affixed. /NAIL \\\\� Drawings not signed and sealed by the engineer shall not be submitted to any authority or used for any purpose where signed and sealed documents are required. m ELECTRICAL ABBREVIATIONS -A -AMPERE M -METER AC -ALTERNATING CURRENT MCA -MINIMUM CIRCUIT AMPACITY AFF -ABOVE FINISHED FLOOR MCB -MAIN CIRCUIT BREAKER AHJ -AUTHORITY HAVING JURISDICTION MCC -MOTOR CONTROL CENTER AL -ALUMINUM MFR -MANUFACTURER ATC,BMS,EMCS -HVAC CONTROLS +, MH -MOUNTING HEIGHT ATS -AUTOMATIC TRANSFER SWITCH MLO -MAIN LUGS ONLY AIC -AMPS INTERRUPTING CAPACITY MOP, MOCP -MAXIMUM OVERCURRENT PROTECTION BRKR -BREAKER MS, MSB -MAIN SWITCHBOARD C or COND -CONDUIT MTS -MANUAL TRANSFER SWITCH CD -CANDELA NEC -NATIONAL ELECTRICAL CODE CKT -CIRCUIT (N) -NEW CT -CURRENT TRANSFORMER NA -NOT APPLICABLE CU -COPPER NC -NORMALLY CLOSED DN -DOWN NF -NON-FUSED DWG -DRAWING NFPA -NATIONAL FIRE PROTECTION ASSOCIATION DC -DIRECT CURRENT NFSS -NON-FUSED SAFETY SWITCH (E) or EXIST -EXISTING NIC -NOT IN CONTRACT E.C. -ELECTRICAL CONTRACTOR NO -NORMALLY OPEN ELEV -ELEVATOR OCPD -OVERCURRENT PROTECTION DEVICE EMER -EMERGENCY P -POLE EMT -ELECTRIC METALLIC TUBING PH ORO -PHASE EUH -ELECTRIC UNIT HEATER NEMA -NATIONAL ELECTRIC MANUFACTURERS EWC -ELECTRIC WATER COOLER `•' O U w WCd ASSOCIATION EWH -ELECTRIC WATER HEATER PB -PULL BOX F -FUSE PC -PHOTOCELL FA -FIRE ALARM PNL -PANELBOARD FCR -FAULT CURRENT AVAILABLE (R) -RELOCATED FCR -FAULT CURRENT RATING RECEPT -RECEPTACLE FSS -FUSED SAFETY SWITCH RM -ROOM FTL FEED THRU LUGS THD -TOTAL HARMONIC DISTORTION G, GND -GROUND TVSS -TRANSIENT VOLTAGE SURGE SUPPRESSION GFI -GROUND FAULT INTERRUPT TYP -TYPICAL GFP -GROUND FAULT PROTECTION UL -UNDERWRITERS LABORATORIES HZ -HERTZ LINO -UNLESS NOTED OTHERWISE HP -HORSEPOWER UPS -UNINTERRUPTIBLE POWER SUPPLY IBC -INTERNATIONAL BUILDING CODE V -VOLT IG -ISOLATED GROUND VFD -VARIABLE FREQUENCY DRIVE J -JUNCTION BOX W -WATT KVA -KILOVOLT-AMPERE W/ -WITH KW -KILOWATT WP -WEATHERPROOF LTG -LIGHTING XFMR -TRANSFORMER RRGD� \� �' CEN F••• ,� *: " CONSULTING ENGINEERS STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING I FIRE PROTECTION j.�bl u►- www d em.com MICHAEL R. TRIPP % t- A FLORIDA P.E. NO.45407 � �� MADE IN THE USA ELECTRICAL ENGINEER STA OF P •� ?` 4901 VINELAND RD #33S, ORLANDO, FL 32811 (407) 845-6630 CERT OF AUTH 5454 jtYs • �•... R •I....'P 0.0 �\\* These Drawings are NOT VALID for any purpose which requires the original DATE 5.20.2019 O �\ signature and seal of the engineer unless the original signature and seal are affixed. /NAIL \\\\� Drawings not signed and sealed by the engineer shall not be submitted to any authority or used for any purpose where signed and sealed documents are required. m Q � � O CL 41� Cf) N ) 3 0 N O\ � CZ D O ' O N CL O U I` O d _ U Nelson Blankenship, AIA mpg 0 f� E t N V U M a, cv y U i ~" V1W CIE y PQ n U 5 5 U 0 p4 U z a�mo Wa= 'C a3 Q O g, � W w r -a w U o w [� Q `•' O U w WCd U ►� W w W O z U M DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER E-001 DATE 10-18-18 2P-F30SS RP2A-10,12 cu- RP2A-11,13 2P-F40SS C CU -7 2P-F30SS i EP1-4,6 r RP1A-3 El P1 InePlA-1 ® RP1A-2 P2 r O 3P1 A-17 U&M �C-.--�21"-F40SS ^I ., - o k��' C • 0 3 O (D rn r 9,21 o r WIN! It 0 RPIA \!, •- % O i� DAMPER (3-2) /P U 2.1 ELECTRICAL POWER PLAN 1 I. """I K411011 MIIbR .1 WA 7: 7 AR M11 t --:--�-^_—+� :� ���. rte. _� �� •����•���� ���TRIM �� ■ i/ ■ sr41©, - F:� SII i ISO! rII i ® _ �� �i. =.iii' •' - _ O RP2A-5 MENS 133 co 1� TION RP2� PI -3 RP1-6 — -i o � � I OELECTRICAL KEYNOTES - 1. CONTRACTOR SHALL RUN PVC CONDUIT UNDERGROUND FROM PANEL TO SUPPLY POWER FOR OPEN OFFICE DESK RECEPTACLES. 2. CONTRACTOR SHALL RUN PVC CONDUIT UNDERGROUND FROM FRAMED WALL TO FRAMED WALL TO SUPPLY POWER FOR OPEN OFFICE DESK RECEPTACLES. 3. CONTRACTOR SHALL COORDINATE BREAKER AND WIRE SIZE WITH ROLLING DOOR SPECIFICATIONS. 4. CONTRACTOR SHALL RUN CONDUIT OVERHEAD IN CEILING FROM PANEL TO SUPPLY POWER FOR DESK RECEPTACLES. 5. POWER PACK TO BE LOCATED ABOVE PANEL IN ACCESSIBLE CEILING SPACE. CONTRACTOR SHALL CONNECT CONTROLLED RECEPTACLES TO POWER PACK ABOVE PANEL AND TO RUN LOW VOLTAGE CONNECTION FROM POWER PACK TO OCCUPANCY SENSOR. 6. CONNECT POWER PACK TO OCCUPANCY SENSOR AS SHOWN ON LIGHTING PLAN. 7. CONNECT DUCT SMOKE DETECTOR TO FACP. REFERENCE MECHANICAL PLANS FOR LOCATIONS. ASSEMBLY 131 A 5 RPl-10 RP1-9 T EF -2 • RPl-31 7777777 !WI!W!ET7 T1 12I MD� LJLJ RPI -12 I RP1-13 ! 11 I L J L1, t_ Wil_F HP22 F Ts L — SCALE: 1/8" = V-0" 7 % .Z*: ':* _ CONSULTING ENGINEERS No. • �— STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING i FIRE PROTECTION wwwrgdengineers.com O . iv .. STA F ' MADE IN THE USA • ;� V p; ♦; 4901 VINELAND RD #335, ORLANDO, FL 32811 (407) 845-6630 /��s''•.O. R...• G��\� These Drawings are NOT VALID for any purpose which requires the original ture and xed AIL,\\V\`` Drawings notseal of signed and scaled scaledrby�theess �engi engineer shall not be submitted ature and sea] are to any authority or used for any purpose where signed and sealed documents are required. MICHAEL R. TRIPP FLORIDA P.E. NO. 45407 ELECTRICAL ENGINEER CERT OF RUTH 5454 DATE 5.20.2019 m Q o C 0 3 O (D rn r cz 0 o r 0 > (D O - U O 2 C L. Nelson Blankenship, AIA Fry E-4 U N a U zW O E-'1 w o w A �i e U0 to C7 Q � � � 7d W 'i °- w W Zw a � Cd Vw o U w w W M U DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER E-1 01 DATE 10-18-18 CL cz cr- CL Nelson Blankenship, AIA 00 LU Lu DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER E-1 02 DATE 10-18-18 >% A 0 CL 41 C13 OA E 0 Nelson Blankenship, AIA rA 0 cn A Z "4 9 Z IL) 0 cd LLI Cfj u! C-) Lu —i LLj DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER E-103 1 DATE 1 10-18-18 t 01 ELECTRICAL LIGHTING PLAN SCALE: 1/8" = 1'-0" CENS�.�/Ai' RGD *. No. ;* CONSULTING ENGINEERS —� : • W— STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING I FIRE PROTECTION O •: /ry/ !!' !� �[/� wwwrgdengineers.00m • • STATE F •: �` _ MADE IN THE USA • p. ♦ 4901 VINELAND RD #335, ORLANDO, FL 32811 (407) 845-6630 .• ......•O•G�G�� These Drawings are NOT VALID for any purpose which requires the original signature and of the engineer unless the original signature and seat are affixed �NA'L \\\\`` seal Drawings not signed and sealed by the engineer shall not be submitted to any authority or used for any purpose where signed and sealed documents are required. MICHAEL R. TRIPP FLORIDA P.E. NO. 45407 ELECTRICAL ENGINEER CERT OF AUTH 5454 DATE 5.20.2019 m A 0 o a� a C .i U) N a) C � 3 0 4 01 Q O O Q) G Cl 0 Q 2 If 5U Nelson Blankenship, AIA A w�� E ra vi ® � o H 0. �ww� o x UU 0 to r A W U o CDU z O v w LU w W a o z U M DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER E-201 DATE _10-18-18 A 0: 55.89 kVA (CONVECTED) 3.08 kVA (OONNEGTED) MFR NEW MDP _ 3; s 0 4 _W �277Jd80 VOLT B 0: 47.05 kVA (CONNECTED) C 0_ TOTAL TOTAL 51.34 kVA (CONNECTED) 154.28 kVA (CONVECTED) 138.73 kVA (NEC220) 186 1 167 1 AMPS AMPS 3P -800A M.C.B. _- a =NOTES: I BREAKER INTERRUPTRATING: _.._ . _V_._ 800 AMP BUS 22,000 i A.LG CKT LOAD DESCRIPTION RATING POLES - kVA kVA kVA A0 Y Bo co COMMENM . PD612ED010-PDM68XX-71VHWF PANEL hiP1 LED 3 3.08 276 1.08 SEE RISER2 FED BY: 11 A 200 A 3 - - - SEE RISER 6.92 kVA (CONFECT®) 3 PANEL EHP 100 A 3 1.35 0.20 1.36 SEE RISER ! BREAKER INTERRUPT RATING: 10,000A.LG 4 A VIA XFMR 100 A 3 30.75 20.451 22.37 SEE RISER APEL 5 PANEL RPI VIA XFMR 100 A 3 20.73 23.64 26.53 SEE RISER WIRE 6 kVA kVA 3 - - - CKT l CKT NOTE 1 7 kVA WIRE GOND 3 - - - LOAD DESCRIP" 10N -A0 8 Co C/B 3 - - - A0 B C LQAD OESCRIPf10N SQE SQE 1/2" 2#12 310 - - - _ mm IP --20 n 1 s 2 n 1 P-20 311 - - - WAREHOUSE LIGHTS 2#12 1/2" 112" 2#12 WAREI-IOUSE LIGHTS 1 3 1 - - -J I 1P-20 3 4 1 R20 1.00 1722.1 3 1/2" 2#12 EXTERIOR LIGHTS = i 1P-20 n '5 1 6 /� 1P-20 A 0: ® 3.08 kVA (OONNEGTED) MFR CATALOG NUMBER NEW PANEL H P WATTS 3 0 1 4 W B 0. A 2.76 kVA (CONNECTED) CREE FP24-40L-35K-10V 1201277 LED 40 RECESSED NOTE 1 B I 277!480 VST . PD612ED010-PDM68XX-71VHWF 1.0 kVA ( ) LED 23 RECESSED NOTE 1 FED BY: RECTANGULAR HIGH -BAY - E .LLQ {FEDBY:,'lumP 1 •�.�%t• 400:�A�MPBU9� OTA 142 6.92 kVA (CONFECT®) 8 l AMPS EXTERIOR SCONCE M.L.O. ��•.lt�r ! BREAKER INTERRUPT RATING: 10,000A.LG TOTAL WALL MOUNTED 8.65 kVA (NEC 220) 10 i AMPS • E. APEL 1201277 LED NOTES: WALL MOUNTED NOTE 1 COND WIRE ISOLITE kVA kVA kVA 3.5 CKT l CKT NOTE 1 kVA kVA kVA WIRE GOND SIZE SEE LOAD DESCRIP" 10N -A0 B 0 Co C/B NO. NO. CTB A0 B C LQAD OESCRIPf10N SQE SQE 1/2" 2#12 WAREHOUSE LIGHTS 0.88 _ mm IP --20 n 1 s 2 n 1 P-20 1.00 - - WAREHOUSE LIGHTS 2#12 1/2" 112" 2#12 WAREI-IOUSE LIGHTS s'= 1.00T _ ` 1P-20 3 4 1 R20 1.00 1722.1 WAREFiOUSE LIGHTS 2#12 112" 1/2" 2#12 EXTERIOR LIGHTS = 0.32 1P-20 n '5 1 6 /� 1P-20 0.13 D(TEPoORLIGHTS 2#12 1i2" 112" 2#12 EXTERIOR SIGN LIGHTS 1.20 1820 �^+, 7 i 8 3P-20 - _ 3#12 3/4" 314" 3#12 -_ 3P-20 9 10 - �r - 11 12 - -;_ 13 14n - 314" 2#10 SITE LIGHTING - 0.76 = 1P-20 n 15 16 /� - 3J4" 2#10 SITE LIGHTWG_ 0.63 1 P-20 17 18 /� -� - X21 22n - e - 23 ! 24, - - 25 26 ,-� 27 28 .,� - 5 29 r 30n F - - v --,31 32- _ - _ X33 34n - - 35 1 36 ,-� - - y.z X37 38n 000 - - n 39 4011--,% - n 41 42 F.T.L. CONNECTED LOAD: LIGHTING FIXTURE SCHEDULE ® •• MFR CATALOG NUMBER PANEL LAMPS WATTS MOUNTING •- A 2X4 ARCHITECTURAL TROFFER CREE FP24-40L-35K-10V 1201277 LED 40 RECESSED NOTE 1 B 277/480 V6Lt!] HALO COMMERCIAL PD612ED010-PDM68XX-71VHWF 1201277 LED 23 RECESSED NOTE 1 FED BY: RECTANGULAR HIGH -BAY 100AMPBUS 1 •�.�%t• 1201277 •• 142 SUSPENDED NOTE 1 11 EXTERIOR SCONCE LITHONIA rr�. BREAKER ��•.lt�r FLOURESCENT 42 WALL MOUNTED EM EMERGENCY BUG EYE LIGHTING • E. APEL 1201277 LED 0.33 WALL MOUNTED NOTE 1 EX EDGE LIT LED EXIT ISOLITE ELT -EM -G -XX -BA -XX -UC UNV LED 3.5 SURFACE NOTE 1 NOTES: 1) Altemate equipment shall be equal to the equipment listed in all respects. •�- •�- ••�..: • • .04 rAAw~-a e .-I a U N rn y • .. •-- • r H O � Hww U O Qat -. - ®._.- _.. Q LIJ sx 7C,3 W o _ mm c 3 N .. =Mwx a4 cml U .-+ J O M W _ ` DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER E-302 DATE 10-18-18 CONNECTED.. 000 LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MFR CATALOG NUMBER VOLTS LAMPS WATTS MOUNTING REMARKS A 2X4 ARCHITECTURAL TROFFER CREE FP24-40L-35K-10V 1201277 LED 40 RECESSED NOTE 1 B 6" LED DOWNLIGHT HALO COMMERCIAL PD612ED010-PDM68XX-71VHWF 1201277 LED 23 RECESSED NOTE 1 C RECTANGULAR HIGH -BAY CREE KBL-A4JV-M-40K-7-UL-10V 1201277 LED 142 SUSPENDED NOTE 1 D EXTERIOR SCONCE LITHONIA MRW 42TRT MD MVOLT LPI 1201277 FLOURESCENT 42 WALL MOUNTED NOTE 1 EM EMERGENCY BUG EYE LIGHTING SURE LITES APEL 1201277 LED 0.33 WALL MOUNTED NOTE 1 EX EDGE LIT LED EXIT ISOLITE ELT -EM -G -XX -BA -XX -UC UNV LED 3.5 SURFACE NOTE 1 NOTES: 1) Altemate equipment shall be equal to the equipment listed in all respects. ``\\\►11111//// ` S�;Q/Ari *: * _ CONSULTING ENGINEERS No. _ it= STRUCTURAL I MECHANICAL I ELECTRICAL I PLUMBING I FIRE PROTECTION 70 . Ltl - www.rgdengiiieers.com MICHAEL R. TRIPP �Q � FLORIDA P.E. NO. 45407 T MADE IN THE USA ELECTRICAL ENGINEER .• ST OF : N P. %.4901 VINELAND RD #335, ORLANDO, FL 32811 (407) 845-6630 CERT OF AUTH 5454 O 1 O R Ci �� .� •..• 01 signature These Drawings are NOT VALID for any purpose which requires the original DATE 5.20. 019 VV signature and seal of the engineer unless the original signature and seal are affixed. N AI L \ \ \ \`` Drawings not signed and sealed by the engineer shall not be submitted to any authority or used for any purpose where signed and sealed documents are required. CO Q 0 0Cd a � N N 0 a1 ~ � O O N ccN a _ v U 0 An 0 Nelson Blankenship, AIA .04 rAAw~-a e .-I a U N rn y U U �y z� o " H O � Hww U O Qat Q LIJ sx 7C,3 W o _ Gq W U' o c 3 N .. W z a4 W (� V� U .-+ J O M W _ ` DRAWN CHECKED PROJECT NUMBER 1722.1 DRAWING NUMBER E-302 DATE 10-18-18