Loading...
HomeMy WebLinkAbout1185 W Airport Blvd 18-3997 Plans Signa Cc co fa rX x N 15 Building 3 - 1205- 1249 II Wesi qir 1 I I ni 1 17— port Boulevard But9 I �1255. '/1295 i Ist Airport Boulevard FDJ On Time wall sign STORMWATER POND Building 2-11 21- 1197 West Air pod '98y/' / / / I I t , Boulevand Leased Available - Shell e Available - Built -Out PERMIT # l Y 3 S ZZ AIRpDRT BOULEVARD _ ARD euiltling 1 - Future 11 1"11"D134 1 4-6 '--zgq� io��c6-1� 5, d Based on 30' linear feet of building length, ok to install one 34.84 square foot "FDJ TOOL" wall signage as shown on plan. Any additional attached signage on canopy, wall or window shall require approved by City of Sanford Planning Department. 1800 Pernbrook Drive, Suite 350 Orlando, Florins 32810 +1 407 875 9989 SCALE: 3/16"=1'-0" 101 r .! 41 — 1 C6 Based on 30' linear feet of building length, ok to install one 34.84 square foot "FDJ TOOL" wall signage as shown on plan. Any additional attached signage on canopy, wall or E .,,VA R4 :. F N. 67382 STX O o RtV uft J W+ Lut C4 7 :a M N •— p i O +� V LL Q) V Affth 7005 Stapolnt Court These drawings and designs are the PROJECT: PROJECT # 7430 window shall require approved by City of 5anrora riannmg Approved SHEET: Winter Park, Fl. 32792 exclusive property of Stellar Sign andDepartment. duplication an Desi n LLC. Use or du in 9 P y FDJTOO L AM: SH PM � Approved as noted -W P. 407.660.3174 F. 321.249.0259 manner including but not limited to electronic transfer without express Revise and resubmit PSV www.stellarsignanddesign.com P Stellar Sign Design LLC Designer: p� p Date: 08-24-18 SITE ADDRESS: 1185 WEST AIRPORT BLVD. STELLARFlorida State Certified permission of and is prohibited. 02017 Stellar Sign and RI V 1 Approved: —SIGN s DESIGN— Electrical Sign Contractor ES 12000915 Design LLC. SANFORD, FL. Sheet Size -11 " X 17" Date: O ON NM TM �2 =JM LL_ R C OM N W LLI= 00 Z mop 00 O Op N w N a N Ln M _14 X Cq E O Ooq II 0 cm 4) O 0) YI in v �O 26 in II N tl= T 4) O O V aO. m V 0 YLn N cc a 3 General -Design is in accordance with the requirements ofthe Fla Bldg Code 6th Ed (2017) for use within& outside the High Velocity Hurricane Zone (HVHZ). -This engineering certifies only the structural integrity ofthose systems, components, and/or other construction explicitly specified herein. •Eledrcalnotes, details,&specficationsare provided by and are the sole responsibility o sl"lh't ofthe electrical ncalcontractocNo electrical review has been performedand no(ertificationofsuchisintended. -Structural design meetsre uirementsofACl31&14, AISC360 10,DMI-15,&NDS-15 Notes: as applicable. • Steel components shall be coated, painted, or otherwise protected against corrosion per FBC Sec 2203.2/2222.6. - Alum components in contact with steel or embedded in concrete shall be painted or protected as prescribed in ADMI-15(la), or plasticineoprene spacers provided. • All exposed fasteners shall be S.S. or have a protective coating for corrosion protection. • All welding shall comply with AWS requirements. • Steel welds: E70xx electrodes. • Aluminum welds: 4043 filler alloy. • Alum extrusions: 6063-T6 or stronger, U.N.D. SIGN I YVt L—L / 3D 3r SCALE: 1/2"=V-0" °-0" "ALL FASTENERS SHALL ANCHOR SCHEDULE BE11,11EDEVENLl* CITY or WALL MATERIAL I ANCHOR TYPE SPACING m � 1/4" THREADED RODS WITH MIN PAIRS AT 157 R 6 Q 2" EMBED IN ADHESIVE 48" O.C. CONCRETE (3ksi) or 1/4" TAPCONS (OR EQUIV) WITH 48IRSS AT OL4O"ALUMINUM HOLLOW MASONRY 1.75" EMBED 1/4" EXPANSION ANCHORS WITH PAIRS AT 4" RETURN 2.5" EMBED 48" O.C. 1" TRIMCAP P AIRS AT 1/4" TOGGLE BOLTS 48" O.C. 1/2" PLYWOOD pAIRS AT 3116" TRANS WHITE (NO ACCESS BEHIND) 1/4" WOOD SCREWS OR ACRYLIC TAPCONS, FULL EMBED METAL STUDS OR #14 METAL SCREWS TO MIN 18ga PAIRS AT 48" O.C. LED METAL PANELS STEEL OR 0.090" ALUM HOLLOW WALL 1/4" THRU BOLTS OR LAGS TO PAIAI RS AT WEATHERPROOF (BLOCKING BEHIND) SOLID BLOCKING BEHIND O.C. BUSHING MIN (3) #10 SMS PER LTRILOGC P I AR) DISCONNECT Q' (NEC 600-6 114" DRAIN HOLES (LETTERS AND RACEWAY) FACE LIT CHANNtL Lt I I rINO ON RACEWAY. TYPICAL ■ A. These drawings and designs are the PROJECT: 700--]-5 Stapoint Court exclusive property of Stellar Sign and FDJTOOL Winter Park, FI. 32792 Design LLC. Use or duplication in any -. P. 407.660.3174 F. 321.249.0259 manner including but not limited to electronic transfer without express www.stellarsignanddesign.com permission of Stellar Sign and Design LLC SITE ADDRESS: 1185 WEST AIRPORT BLVD. I d State Certified s rohibited. ©2017 Stellar Sign and ANFORD FL REF ANCHOR SCHEDULE kLUM RACEWAY (VIF EXISTING) •11 • PROJECT # AM: SH PM MR BLACK I WHITE DISCONNECT SWITCH Based on 30' linear feet of building length, ok to install one 34.84 square foot "FD1 TOOL" wall signage as shown on plan. Any additional attached signage on canopy, wall or window shall require approved by City of Sanford Planning Department. Designer: RM I Date: 08_24_18 Sheet Size - 11 " X 17" CHANNEL as 6 382 %-4 E OF PMSI PMS I PMS 7688 7507 3935 r m � PMS J `' 157 R 6 Q v LL d v SCOPE: - FABRICATE (1) SET OF FACE LIT CHANNEL LETTERS AND INSTALL ON RACEWAY IN SIGN BAND AT TENANT LOCATION. 3/16" TRANSLUCENT WHITE ACRYIC FACES. BLACK TRIM CAP BLACK RETURNS RACEWAY PAINTED SW 7046 ANONYMOUS ELECTRICAL EQUIPMENT NOTES - LED - PRINCIPAL STREET FIGHTER SIDEKICK (PL-OP3-SK3-P-TW)* - 46 MOD REQ'D *OR EQUAL - POWER SUPPLY - PRINCIPAL UNIVERSAL (PL -60-12-U)* - 2 REQ *OR EQUAL CIRCUIT (BY OTHERS) -1-120VAC 20 AMP CIRCUIT REQ'D (2.2 AMP LOAD) 0,,�sTEO Florida State Certified ME s Electrical in Contractor E21257o ES 12000915 ALL ELECTRICAL COMPONENTS WILL BE UL LISTED AND APPROVED AS PER 2014 NEC 600.3 AND MARKED AS PER NEC 600.4. THE INSTALLATION OF THE WIRING WILL BE DONE AS PER FBC 4505.4 AND DESIGNATED TO UL 48. ALL SIGNS ARE TO BE GROUNDED AND BONDED PER NEC 600.7 AND 250.122. AN ELECTRICAL DISCONNECT WILL BE PROVIDED PER NEC 600.6. AND CONTROLLED BY TIMER / PHOTOCELL ALL WIRING INSIDE LETTERING WILL BE LOW VOLTAGE UNDER UL SIGN ACCESSO- RIES MANUAL (SAM) E242084, LISTED AND APPROVED AS PER 2011 NEC 600.3 AND MARKED PER NEC 600.4. PRIMARY ELECTRICAL SOURCE TO BE SUPPLIED BY CUSTOMER WITHIN SIX (6) FEET OF SIGN. ALL PRIMARY WIRING WILL BE #12 THWN. THIS SIGN IS A UL LISTED ASSEMBLY PER NEC 600.3 REVISIONSN SHEET: Approved -RIPTION NGED LOGO TO CHANNEL LETTER- RM Approved as note Revise and resubmit Approved: 0 ON m TM em- 3Mr =JM v M o@C� LLLCr op ZV r 00 O [� SWUM( Fon a p S ®sr 6 DESIGN Electrical Sign Contractor ES 12000915 Design LLC. All welding shall comply with AWS requirements. • Steel welds: F7Dxx electrodes. •Aluminum welds: 4043 filler alloy. •Alum extrusions: 6063-T6 or stronger, U.N.( ofthosesstems,components,and/or other construction explicitlyspecinedherein.•Electricalnotes,details,&specifiaenersshations are lrbeSS.orhaverapmtectivePoatlngllforocorrosilooprotectionactor.Noeleet9calreviewhasbeenperformedandnocertificationofsuchisintended.•StructuraldesignmeetsrequirementsofACl318-14,AISC360-10,ADM1-15, -� General -Design is in accordance with the requirementsoftheFlaBldgCode6thEd(2017)forus@within& outside theHighVelocityHurricaneZone(HUHZ).•Thisengineeringcertifiesonlythestructuralintegnty y .�_. �. o Iii,aNP_ • Steel components shall be coated, painted, or otherwise protected against corrosion per FBC Sec 2203.2/2222.6. • Alum components in contact with steel or embedded in concrete shall be painted or protected as prescribed in ADM1-15(ta), or plastidneoprene spacers provided. •All exposed fast