HomeMy WebLinkAbout113 S PALMETTO AVE (A) 18-3818 AWNING,:'IIII .a
L S -`So L8
14'-9" AFF
On
2 SIDE VIEW
Scale. 1/2 = 1'-0"
10-1" AFF
0
�3"
Job Number
rame Qty.:
1 FRAME
rame Size:
1" SQ
rame Material:
Aluminum
rame Finish:
PAINT
inish Color:
BLACK
Inderside Color
3/8"x3 %"
3/8"x1 %8'
CAULKING BEAD
SCREW ANCHOR,
SLEEVE ANCHOR,
FRAME MEMBER ° ° UNDER FRAME
MIN EMBED 3",
MIN EMBED 1 Y2",
p Mounting Option
2 #10x%4"
TEK SCREW ° SIDE OF FRAME
Cover Color:
BLACK
" x 1 Y2" WIDE Mounting Option
2 #10x%4'
TEK SCREW
STEEL BRACKET
FASTENER ABOVE FRAME
SEE BELOW o ° Mounting Option
Job Number
rame Qty.:
1 FRAME
rame Size:
1" SQ
rame Material:
Aluminum
rame Finish:
PAINT
inish Color:
BLACK
Inderside Color
3/8"x3 %"
3/8"x1 %8'
SCREW ANCHOR,
SLEEVE ANCHOR,
Sides:
MIN EMBED 3",
MIN EMBED 1 Y2",
OPEN
Type of Cover:
Sunbrella FIRESIST 8200
Cover Color:
BLACK
Valance:
1011
NOTE: ATTACH INTO MORTAR (NOT ON BRICK)
4 / WALL ATTACHMENT OPTIONS
1 ISOMETRIC
Scale: NTS
WALL ATTACHMENT OPTIONS
LOOSE STRAIGHT
Applique:
No Applique
Binding:
BLACK
GRAPHIC
Lace bar:
No Lace Bar
Note:
All framing is made of 1"Sq tube 1/8" wall and
ground smooth.
All aluminum to be 6061-T6
Aluminum Weld: IAW AWS D1.2(latest edition).
Filler Alloy: 5356 or equal
All fabric is fire retardant.
All hardware to be 304, 316 Stainless Steel.
This structure has been designed to comply with
Chapter 16 of the Florida Building Code 2017 6th
Edition and ASCE 7-10. The design parameters
BRYAN A. MOLYET P.E. are:
1060 East Industrial Dr, Ste, W
Orange City, FL 32763 ' Vult: 140 mph
(386) 532 8000 Vasd: 108 mph
Reg. Fla. Engineer No. 041509 Risk Category: II
Exposure: C
Florida Certificate of Authorization No.00032041 GCPi +/-0.18
Floor Live Loads (psf) 10
NOTE: Uninhabitable attics without storage 20
These structures have been designed so that the fabric will be Uninhabitalbe attics w limited storage 30
removed during periods of time as designated by the U.S. Habitable attics and sleeping areas 40
Weather Bureau as being a Hurricane warning or alert in All other areas 10
accordance with Section 3105.4.2.1 of the 2017 Florida Bldg. Roof Live Load: --
Code 6th Edition. Component & Cladding +25.6 -34.3