Loading...
HomeMy WebLinkAbout3111 W 1 St 17-618 HVACECEIV I t CITY OF SANFORD APR 19 2017 BUILDING & FIRE PREVENTION PERMIT APPLICATION Br 1 — t Application No: - I Documented Construction Value: $ l p Job Address: Svc W xt Sr Historic District: Yes No Parcel ID: 33ON _ ODOO Residential Commercial k1 Type of Work: New Addition ElAlteration Repair Demo El Change of Use Move El Description of Work: Rp(h+n ('?j SD1-`e=S S"MS Plan Review Contact Person: Title: Phone: Fax: Email: nn Property Owner Information . 1 ,, ' \ Name Qtf\T[a D{'1'S7C 111rt lt] Phone: `i6t'3a9—t1`t Street: 3 0 W• fin~ Resident of property? c City, State Zip: anaca c Contractor Information A+ _ Name — Y Phone: 'F A i Street: C Olr Fax: City, State Zip: State License No.:cq Name: Street: City, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5th Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application —70 Application is hereby made to obtain a permit to do the work and installations- as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all ,laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records. -of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documentea construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Signature of ContnctodAgent Date 1 ,,,, rr t horn" 1. riXnn _ Print CcAtractor/Agent's Name of LORI LOCIOM MY COMMISSION N GG 0009T EXPIRES: J* 5, 2= Bw&d Thm Nd m RM uwww tets II Contractor/Agent is Y, Personally Known to Me or Produced ID Type of ID WASTE WATER: BUILDING: Rev 11.08 1 CH. pl im p R 0ter. Mfg CCXDM6klr!C3 & I?LE.'I RIG 8'EME, State Certified CACO29393 - CFC1426770 PIVAC INSTALLATION PROPOSAL i i For McKee Construction Co. 190 Monroe Rd. Sanlord. F 1. 32771 5. McKCONSTRUCTION GENERAL Service Hotline: 407-291-1644 . Toll -Free: 800-305-5187 www. ProTechAC.com • Service@ProTechAC.com 2425 Silver Star Road • Orlando, FL • 32804 www. FaceBook.cc n/ProTechAC s P R 0 -T E C A-fRi"'(36d1 mol .4c, & f t.twiki a smim wt-e • January 3, 2017 Valid for 30 daYs aflei proposal written Customer Name: I McKee Construction C'o. Site Address: _ _ Central Baptist Church Youth Center 3101 }Nest State Road.46, Sanford, FL 32771. ___ System Features: Meeting Rooms. l) 4 Ton Trane High Efficiency Variably Speed Heat Pump system with (3) full variable zoned system; (1) per meeting room. 3) zones controlled by (1) 950 Wi-Fi enabled wall mounted thermostat and (3) wall mounted sensors. Provide (3) individual smoke detectors for each new.system. Multi -Purpose Room and Room 107 1) 4 Ton Trane Heat Pump system. 1) 824 Wi-Fi enabled wall mounted thermostat to control 4 Ton Heat Pump system. 1) 3 Ton Trane 2 Speed Heat Pump system - 2) zones to provide cooling/heating,to multi -purpose room 106 and meeting rootn 107 independently. 2) 824 Wi-Fi enabled wall mounted thermostats with (1) bypass damper to regulate temperatures in both rooms. Provide (3) individual smoke detectors for each new system. Outside Air 2) Intake louver's (Ruskin EME520MD or equal) and (1) Exhaust louver (Ruskin EME520MD or equal) to connect to mole sink. Control System The control system set-up and design is the same as the new control system in the main building. Warranties Pro -Tech Warranty Trane Warranty 1 year labor warranty by Pro -Tech Air Conditioning- yr` and Plumbing Service. Compressor 5 Parts 1 Outdoor Coil 1 Indoor Coil 1 Note: See manufacturer information on line fir actual xk.nr.utty coverage's. MaN require m%ner to complete online regisUation for warranty activation. Your comfort system %+ill he installed with the highest quality. care. and workmanship and will comply tt ith all governing codes and regulations: Customer Initial 1 21r: IRA "R M!m AIR CONDii ONING & PLUN81NG SERVICE, INC. Location of couinment The new (3) outside Trane condensing units will be located outside the building on the south side at a location confirmed by General Contractor. As shown on drawings. The air handler serving Meeting Rooms100-102 will be located above the acoustical ceiling in Corridor 103. The (2) air handlers for Multi -Purpose room 106 and for Meeting Room 107 will both be located in Room 106. one on the south east side of the room and one on the north east side; -in the -ceiling spaee.at an eIelalion ronfinrted_by_General.Contractor._____ Scope of work Install new Trane 4 Ton XV20i High Efficiency Variable Speed heat pump system_ with (3) zones. Includes (1) 950 Wi-Fi enabled thermostat and (3) individual room wall sensors. Outdoor unit to mount (in concrete pad and attached at each corner with equipment provided bracket. Concrete pad provided by General Contractor. Install new Trane 3 Ton XR17 2 speed heat pump system with (2) zone dampers. Includes (2) 824 thermostats with (1) bypass damper. Outdoor unit to mount on concrete pad and attached at each corner with equipment provided brackets. Concrete pad provided by the General Contractor. Install new Trane 4 Ton XR14 heat hump system. Includes(]) 824 thermostat.. outdoor unit to mount on concrete pad and attached, at each corner. with equipment provided bracket. Concrete pad provided'by general contractor. Will furnish (2) new intake louvers and connect to new equipment. Louvers to be installed by General Contractor. Install (1) new exhaust fan above mop sink and pipe work to new louver. Pro Tech will furnish new louver for general contractor to install. Furnish & install all low voltage thermostat control wiring., Supply and return duct design and installation - Install (3) 5 inch media filters; one per unit. Install condensate PVC lines and copper refrigerant lines for each unit. Condensate lines to drain to grass area at exterior of building. System startup will be performed by a Pro -Tech certified technician and will be checked to ensure all manufacturer specs are being met through quality assurance, analysis. Cut and patch any necessary,hole_s at the time of installation. No exterior metal panel patch work included. Sweep, dust, and vacuum at the end of each day's work. All installation debris from site will be removed and placed in onsite dumpster i provided by General Contractor. NOT INCLUDED 1N SCOPE OF WORK Cost of electrical work is not included in our proposal. Cutting and installing 3 intake louvers. All exterior metal siding patching or repair. Concrete pads Fire alarm Customer Initial GONSTnucrnoN CO. GEE ERAL CONlTRACTORS 790 Monroe Road Sanford, FL 32771 Phone: (407) 323-1150 Fax (407) 323-9304 SUBCONTRACT AGREEMENT CONTRACTOR: McKee Construction Co. CONTRACT NO: 2017-02--08 SLIBCONTRACTOR: Pro -Tech Air Conditioning & Plumbing Service, Inc. JOB NO: 2017-02 PROJECT: Central Baptist Church ADDRESS: 3101 FtA6 Sanford FL 32771 DATE: February 24, 2017 CODE: 15600- S43,487.00 CONTRACT PRICE ONCLUDES ALL TAXES) NOT TO EXCEED $43,487.00 WITH 10% RETAINAGE. PAYABLE AS FOLLOWS: BILL AS PER BILLING SCHEDULE PROVIDED, ONLY MCKEE CONSTRUCTION CO. SUPPLIED PAY APPLICATION WILL BE ACCEPTED. APPLICATIONS ARE DUE BY THE 20TH OF EACH MONTH. SUBCONTRACTOR PAYMENT WILL ONLY BE PAID WHEN THE CONTRACTOR IS PAID BY OWNER. PER CONTRACTOR'S CONTRACT WITH OWNER, OWNER SHALL PAY CONTRACTOR BY THE 10TM OF THE MONTH. ALL LIEN LAWS ARE APPLICABLE. RETAINAGE TO BE HELD UNTIL THE CONSTRUCTION OF 1 HE PROJECT IS COMPLETED. (SCOPE OF WDRK WRrnFN SCHEDULEM(IST BE PROVIDED PRIOR TO 1ST APPLICATION FOR PAYMENT BEING PROCESSED 1. Subcontractor agrees to perform all labor in a workmanlike manner, to prosecute said work in accordance with Contractors schedule and to complete all work in a prompt and professional manner. Subcontractor is required to clean up scope of work lob debris on a daily basis, failure to maintain this Policy will result In McKee Construction Co. hiring dean up workers which will result in a backcharge to the subcontractor. 2. Subcontractor further agrees that he has in full force and effect this date and will continue in force during the course of his work, Workmen's Compensation Insurance, as required by law, and Public Liability and Property Damage Insurance as is reasonably necessary to insure against the risk arising out of this contract. A certificate of said insurance Is to be received by the Contractor within three (3) days following the execution of this contract. In no case will any work be commenced prior to receipt of the Certificate by the Contractor. "Prior to the completion of work operations on this property, -none of the above insurance Is to be cancelled, changed, or allowed to lapse until 30 days prior written notice has beer given to the Contractor." 3. In addition to standard manufacturers warranties for any equipment installed by Subcontractor, Subcontractor guarantees all work against defects from the use of Inferior or defective materials, equipment or workmanship for one year from the date of occupancy by the owner. All repairs or changes required in connection with this Guarantee will be performed promptly at the Subcontractors expense. 4. Subcontractor required to acknowledge McKee Construction Co. safety policies manual on site, and adhere to all such policies. McKee Construction Co. requires hard hats to be worn at all times on jobsite, failure to adhere to this policy will result in the immediate expulsion of violators from jobsite. The subcontractor agrees to furnish McKee Construction Co. with Material Safety Data Sheets for all hazardous materials that will be used on this project by subcontractor or his sub -subcontractors. 5. The subcontractor Is to comply with all current OSHA regulations. Safety for the Subcontractors employees is the responsibility of the Subcontractor. Subcontractor shall maintain a competent person on site during the course of the subcontractors work. In the event that the Subcontractor Is in violation on any OSHA safety regulations, all loses, damages, and expenses incurred including OSHA fines Incurred as a result of said violation shall be home_ by and charged against the Subcontractor. 6. Mckee Construction Co.adfiere's to a drug free work environment. All companies and their employees who perform work under this subcontract agreement on McKee Construction Co. jobsites are subject to random drug testing as a requirement of this contract If refusal or positive testing takes place McKee Construction Co. reserves the right to ban from performing work under this contract individual or individuals that violate this policy. 7. McKee Construction Co. requires the subcontractor to have on jobsite at all times at least one English speaking employee. Violation of this agreement will result in immediate termination of this subcontract If termination of contract occurs. subcontractor agrees to cover any cost overage's that may take place in completing the scope of work. 8. As part of the acceptance of this Subcontract, Subcontractor will provide to McKee Construction Co. a list of all principal's and key employee's home and cellular phone numbers. Monthly Pay request will not be paid until these numbers have been supplied to McKee Construction Co. If at any time the Subcontractor fails to respond in a timely manner, McKee Construction Co. has the right to terminate said contract as described in paragraph 7. 9. Subcontractor Is responsible for the maintenance of their scope of work items until Certificate of Occupancy is secured. 10. This Subcontract Agreement can be terminated by McKee Construction Co. if Subcontractor makes any false statement to McKee Construction Co., Including, but not limited to, any false statement which would subject Subcontractor to criminal charges pursuant to Section 713.35, Flolyda Statues. 11. Jobsite meetings will be scheduled regularly. Subcontractor shall have at -least one employee at a timely scheduled jobsite, meeting for but not limited to the following reasons: safeey, job schedule, quality of work or failure to perform. Accepted: Contractor Accepted: Subcontractor McKee Construction Co. Pro -Tech Air Conditioning d Plumbing Service, Inc. 790 MONROE ROAD 2425 Silver Star Road SANFORD, FL 32771 Orlando FL 32804 Signature: Authorized Corporate Signature: Print Name: Date:_ Print Namey%th ,t 7, A/ -h Title: l l, d -" Date: Since !47? OR X_TI EEC UP AiR CONDffMINC & PLUMBING SERVICE, INC. Maintenance Periodic system maintenance is necessary fir this system to operate correctly and keep the manufactures warranties in force. We \\ ill update the church's maintenance agreement so they will know the additional cast. Terms of Agreement In the event payment is not made promptly in accordance with agreed teens, it shall be the Seller's option _to_charge.a service'charge.not excee 'din" I V, per.month._The.first_---- service charge will become due 30 days from the date of the billing of our amount due on the job. In the event of collection by Attorney, all Attornevs', court costs, and other legal fees shall be borne by the Buyer: in the event of non-payment, Buyer agrees to allow. Seller on the premises to remove the equipment installed. This investment proposal shall j be binding upon the heirs, successors. or assigns of the parties hereto. It is understood that the title of all the products and equipment covered by this agreement remains solely in the Seller, until the entire purchase price has been paid in full and the I manner of installation and/or attachment to any equipment and/or any portion of the building structure in -which the installation is made shall not in any manner the Seller's title. Exclusions ANY ADDITIONAL. NEEDED WORT: NOT MENTIONED IN THE I311F01Rl. MI:NTIONED SCOPE OF WORE- POWER WIRING. FIRE ALARM OR FIRE ALARM REPLACEMENT. ROOF WORK. CONDUIT. STRM"rURAL SUPPORT. HOLE CUTTING. GAS PIPING. DUMPSTE•R. HOLE PATCHING. DISCONNECT S\\ITCHI.S. INTERLOCKING. DEMO. PLUMBING. WARRANTY ON EXISTING EQUIPMENT. QUICK SIiIP FEES. CLILING III.E RL•MOVAIJREPLACEMENT, CEILING GRID REMOVAUREPLACEMENT. ASBESTOS ABATEMIM' :\ND BOND PREMIUM. FIRE SMOKE D1-1'ECTUR Sl'STI:MS, ELECTRIC WORE. ALL PARTIES AGREE AND HAVE ACCEPTED THE PRICE, SPECIFICATIONS, AND CONDITIONS ARE SATISFACTORY. I have the authority to order the work outline above. The cost of to comple $43,487.00 McKee Representative, authorized signature Date Wednesday, January 04, 2017 Tom Nixon, Pro -Tech Air Conditioning & Plumbing Service Date Customer Initial r-ino t COUNTY OF SEMINOLE IMPACT FEE STATEMENT t 18Li, 4q'q STATEMENT NUMBER: 17100001 DATE: March 07, 2017 BUILDING APPLICATION #: 17-10000100 BUILDING PERMIT NUMBER: 17-10000100 UNIT ADDRESS: W 1ST STREET 3101 26-19-30-5AE-330A-0000 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: i APPLICANT NAME: CENTRAL BAPTIST CHURCH SANFORD ADDRESS: 3101 W. 1ST STREET SANFORD FL 32771 LAND USE: STORAGE BLDG CHANGE OF USE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 3101 W 1ST ST. / EXITSITNG 4950SF STORGE BLDG CHANGE USE TO YOUTH EDUCATION BLDG FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS- ARTERIALS CO -WIDE ORD Church 448.00 4.950 1000nsft 2,217.60 ROADS - COLLECTORS N/A Church . 00 4.950 1000nsft 00 FIRE RESCUE N/A 00 LIBRARY N/A 00. 00 SCHOOLS N/A PARKS N/A 00 LAW ENFORCE N/A 00 DRAINAGE N/A 00 CREDIT FEES- SCI ROAD ARTERIALS C Warehousing* 358.007_). 9( 50;000g ft 1,772.10- AMO445. 50 STATEMENT/ RECEIVED BY: i SIGNATURE: PLEASE PRINT NAME) DATE: NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABI Y FOR THE FEE. *** DISTRIBUTION: 1-BLDG DEPT 3-APPLICANT 2- FINANCE 4-LAND MANAGEMENT NOTE** PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES DUE UNDER THE SEMINOLE COUNTY ROAD, FIRE/RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE, BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE POP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE DETAIL OF CALCULATION AVAILABLE UPON REQUEST. CALL 407-665-7356. Job Address: 3111 %,. - r CEaV BY CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: I l' t Documented Construction Value: Historic District: Yes No 21 Parcel ID: Residential Commercial tz Type of Work: New Addition AlterationZ Repair Demo Change of Use Movie Description of Work: lct,cs 1 w1C, o aFL Plan Review Contact Person: A_ Title: S Aoe- EsrnAke t Phone: Fax: Email: Property Owner Information'=f Name aF -G& 1F-bM Street: 3101 City, State Zip: -f:,tJFvQA Phone: Resident of property? : yES Contractor Information Name Mc-kEC-C 6a. Phone: Street: 'Ylo 1.11ot,¢ptc 12 City, State Zip:14-e 2 'a111 Fax: 4J'l - 't-D-'Ab.-'I State License No.: C6c- t'LSWS 30 Architect/Engineer Information Name: /t-Ie_R(T&c.t\.4CA%_ 1).(k1A-WLlc.S l"C-. Phone: 4->-1- Street: 2,'31(e Ptcx,F-a.a_ szV.e:y_c--r Fax: City, St, Zip: E-mail: e-wd..s We &_a0k.CC"' Bonding Company: ate Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 551h\Edition (2014) Florida Building Code Revised: June 30, 2015 1 i I S D T J v Permit Application S - ISld•s o .SP NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructiAn and zoning. 2,217 rgnature of Owner/Agent Date Print 0%vner/Agent's Name Signature orNotary-State of Flon JPHEN C. ESLERDate NOTARY PUBLIC STATE OF FLORIDA Ca vm# FF148915 Expires 11nr2018 Owner/Agent is C, Personally Known to Me or Produced ID Type of ID 3 Contractor/Agent I Date rFfA l tA 01COZ ks Print Contractor/Agent's Name Signature otNota-State TrrrN C. ESLERDate NOTARY PUBLIC STATE OF FLORIDA Comrr* FF148915 Expires 11/7/2018 Contractor/Agent is L,-Ilersonally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: (1-4'4' ccupancy Use: ,6'1,st'>we>if Flood Zone: _ Total Sq Ft of Bldg: O Min. Occupancy Load: 4e0 # of Stories: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: Plumbing - # of Fixtures of Heads Fire Alarm Permit: Yes No UTILITIES: WASTE WATER: FIRE: BUILDING: ? ul% Revised: June 30, 2015 Permit Application r 1 ' E By: CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: I I — / ( Y t Documented Construction Value: Job Address: 3111 V3. Historic District: Yes No 21 Parcel ID: 1°I 2-jr-*> -SAE - 33a A - o00o Residential Commercial 2 Type of Work: New Addition AlterationZ Repair Demo Change of Use Movie Description of Work: ENS 1N4 d4::: oPC-_0 Plan Review Contact Person: j t,tUi-aLkS Title: 56.uae EsntAATN Phone: 4a"1- 3a3-1(So Fax: Email: o rv,lue e-• co•, Property Owner Information NameGtJ¢cH br- Sh fbM Phone: Street: 3101 .l . l --g -re--c Resident of property? : '46S City, State Zip:F%>¢ ' f-7- 3a-)1( Contractor Information Name Cawy>wu_v.-obo-N 66. Phone: iJ"1 -3z3-1tSa Street: —) o Fax: 4a- I - 'A_>'o- City, State Zip: & 3a-1'11 State License No.: CLSW 30 Arch itectlEngineer Information Name: 11tii,4mmcs i"c_ Phone: t-1->i - Street: 2!31(e Pic g-F- -9- szyr=g-_-r Fax: City, St, Zip: E-mail:g vcA,%sx.14 e- g_Qo1. CC_% .% r Bonding Company: t'I CA, Mortgage Lender: Address: Address: WARNING TO OWNER: -YOUR FAILURE TO' RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws'regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. v ignature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of FIoSTPHEN C. ESLERDate NOTARY PUBLIC STATE OF FLORIDA Conn* FF148915 Expires 11n12018 Owner/Agent is i/ Personally Known to Me or Produced ID Type of ID 9/z/P0/-7 Contractor/Agent I Date Jt "A rA Otc"LkS Print Contractor/Agent's Name Signature of Notary -State Si WkN C. ESLEF2Date ivNOTARY PUBLIC STATE OF FLORIDA Comm# FF148915 Explres 11/7/2018 Contractor/Agent is. t-'15'ersonally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: wTC- 3_7,1-t1 UTILITIES: ENGINEERING. MtL 3.2?-11 FIRE: COMMENTS: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application r ta 6 2017 a CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application' No: I _% Documented Construction Value: $ Job Address: 311 \ L.I . 1 SST ^ Historic District: Yes No 21 Parcel ID: DL(. - 1 q - 2-o -SAE - o00o Residential Commercial 1z Type of Work: New Addition AlterationR) Repair Demo Change of Use Movie Description of Work: o4 oA_0 fE2&A L)mo6e- e_xmmmc,yLae,P 11,J r&2-( VL tc_0c v jT- Plan Review Contact Person: _jig IIJICtt/r5 Title: S6,yo2 C5NtA/A-tP_ Phone: Fax: Email: ' at_ n-,clime e-. cxxv% Ili Property Owner Information Name C-K-)9" ed- SA"Af-bM Phone: Street: 310\ %,eA . ISM :• Resident of property? City, State Zip: -ff&r1Fv" Contractor Information Name Phone: Street: —) 1 o Fax: City, State Zip: S.1c- 3a-111 State License No.: C-P_je_' CLS41 30 Architect/ Engineer Information Name: ! yf_tftt&chat. 0-4ta, Ames i"c_ Phone: 4->"1- Street: 203 (a Ptc.K.-F-A..2 'r City, St, Zip: Bonding Company: a C( Address: Fax: E- mail: avcl..s.Vse_ (E_ao1.cov%, Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER, OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws -regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51^ Edition (2014) Florida Building Code Revised: June 30, 2015 . Permit Applicat'on 1 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 3 - D ignature of Owner/Agent Date 4 /f Gam../ A? J Print Owner/Agent's Name Signature of Notary -State of FIoSTPHEN C. ESLERDate NOTARY PUBLIC STATE OF FLORIDA Cortm# FF148915 Expires 11/7/2018 Owner/Agent is C, Personally Known to Me or Produced ID Type of ID 3/z/20/7 Contractor/Agent J Pit 1 A Otc.rtnuA-S Print Contractor/Agent's Name Signature of Notary -State gyf 09kN C. ESLERDate NOTARY PUBLIC STATE OF FLORIDA Comm# FF148915 Expires 11/7/2018 Contractor/Agent is t,-rersonally Known to Me or Produced ID Type of ID - BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: IUTILITIES: ENGINEERING: COMMENTS: FIRE: Fire Alarm Permit: Yes No TE WATER: BUILDING: Revised: June 30, 2015 Permit Application CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION DATE: PERMIT NUMBER: BUSINESS/PROJECT NAME: FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 17- (S -- ADDRESS: CONTACT NAME: PHONE: PLAN REVIEW INFORMATION CO :::ION [ ]C/O [ ] FIRE ALARM [ ] FIRE SPRINKLER [ ] HOOD [ ]PAINT BOOTH [ ]TANK DOES ° FIRE IMP TOTAL FEES: L"-f ; b'L MAR 0 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: I I - n I c Documented Construction Value: $ I Job Address: 3111 \,J. Historic District: Yes -No 21 Parcel ID: --IU - 10(- 2-o -SAE - 33a A - o00o Residential Commercial Type of Work: New Addition AlterationQ Repair Demo Change of Use Movie Description of Work: of oW_-0 A-2&A L)m0 2 t tV Tcr li b 2 tc_.t.7 tx T Plan Review Contact Person: tCttz:4_kS Title: Sb.to2 C- 5h tAAT Phone: 4a'1- 3a3- ItSo Fax: 461-32:S-(6 4 Email: e- wc(&.e e-- coy- Property Owner Information Name 6e-NXV-A-A- f6pnsT GKJ9c-N bf- SPA-Wb&4 Phone: Street: a IcA Nr3 - 15'_ -_-2Vve-c Resident of property? : yES City, State Zip: r1f,o2,3 f-c- 3a') I Contractor Information Name NAc_k.C Phone: Lk 0-1 - 3s3-1 t5r Street: Fax: 46-1 - "-'>- 91A City, State Zip: Sps -e ';wrl 1 State License No.: C-P_-e__ CLSWF 30 Architect/Engineer Information Name: Ayr_tfinecTva_Arc_ 1)-ItitA,,ntc.S lac-. Phone: 4->'1-17-5'VC I Street: Z`31(o PicAr-PA- 0- Fax: City, St, Zip: o1Q-v ft_ 32tB63 E-mail: cwd..sP1•e Q I.cor+, Bonding Company: V 4 & Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A, NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO- YOUR PROPERTY. A NOTICE OF COMMENCEMENT. MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws'regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional pen -nits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current 1CC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the pen -nit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructign and zoning. 19nature of Owner/Agent Date 6 Gam. R . Print Owner/Agent's Name Signature of Notary -State of FloST PHEN C. ESLERDate NOTARY PUBLIC STATE OF FLORIDA Coinm# FF148915 expires ilnr2018 Owner/Agent is L/ Personally Known to Me or Produced ID Type of ID Contractor/Agent r Date Jt A IJtatz)%_*S Print Contractor/Agent's Name Signature of Notary -State 06*090-N C. ESLERDate NOTARY PUBLIC STATE OF FLORIDA Comm# FF148915 Expires 11n/2018 Contractor/Agent is L-'ersonally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof Construction Typ Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No UTILITIES: ab 3'03' WASTE WATER: FIRE: BUILDING: Revised: June 30, 2015 Permit Application 1 0F'1V 2017MARDg CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: I T— % ( t Documented Construction Value: Job Address: 311 \ „ . 1' STa-r Historic District: Yes No Parcel ID: Dd.- 101- -SAE - Residential Commercial JZ Type of Work: New Addition Alteration14 Repair Demo Change of Use Movie Description of Work: o,P: oHr=•.3 IN%52.tbrL tc_.Ucac.)T Plan Review Contact Person: I .SLC WOLks Title: SEwe2 G5h WeV&_ Phone: 46'1- 3a3-1(So Fax: Lkc,'l Email: n,,l .se e-. C,o•, Property Owner Information Name (6"nsf GAJ¢cH aF Skr1FaM Phone: Street: 31cA %#S • ls :• Resident of property? : 1IC-S City, State Zip: Pr1fv2 -L- 3a"1"1 l Contractor Information Name Mc_V_e:6_ Phone: kA0-7 Street: Mc*3e.,E, t2) Fax: 46'1 - City, State Zip: SFvS-- State License No.: CP--r-- t'LSW 30 Architect/Engineer Information Name: AVf_ (re' Ai_ 1)4K1Amgc_s I &sc- Phone: 4,>'1- Street: 2 31(a Plcy_FA t _ sz 2c -t City, St, Zip: ft- 32 3 Bonding Company: AEI Address: Fax: E- mail: a d^s=A\e- &-ciol.cov+., Mortgage Lender: tJl Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws'regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers; heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application 1 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional pen -nits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructign and zoning. tgnature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of FIoSTPHEN C. ESLERDate 10NOTARY PUBLIC STATE OF FLORIDA Comm# FF148915 eXPIrss 111712018 Owner/Agent is L; Personally Known to Me or Produced ID Type of ID 3/z/-Jo/7. Contractor/Agent r Date J—AEI M rJtLA-s Print Contractor/Agent's Name Signature of Notary -State If WkN C. ESLERDate ivNOTARY PUBLIC STATE OF FLORIDA Comm* FF148915 Expires IIf1/2018 Contractor/Agent is LIrersonally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures, Fire Alarm Permit: Yes No WASTE WATER:,'! BUILDING: Revised: June 30, 2015 1 Permit Application f 4 . Y r , - , ,.• ,-1 • - it . , ,f, , r r r Y ' CONSTRUCTION CO. GENERAL CONTRACTORS' : r K f' Since•1973 `! r" March 2, 2017 r' f TMr. Dave Aldrich ' r G ,BuildingOfficial- r . rt t, ' • a {' r Cityof Sanf6rd,Buildmg 6epartiiient _`r 1 rJ j 1 r,F-,,300,N6ith NWAve e,4.-' J, ; : Sanford' Florida 3277'1 •:= - t yt 1 rr * r r' r K ', ,' 7 r r f r Re: Central Baptist Church' 3101 W'1't Street —Building EnclosureBuild'out`Cost Breakdown , r r t f - rr F' 0 ' r n. The following is an itemized estimate of the expected'construction costs associated with , r the 'construction ofati Building ericlosure/interi; buildout -for-• Central Baptist Church , F { x located at 310L W 1,` Street.inSanford; Florida. ,= r-y r , k l J 1 , tBuildingScope - - Gerieral Coriditi , $ 17 981.00 Concrete ^ r; {' ^ $ 950.00 r Metals '$ 40,864.00 Woods and Plastics `$ 3,038.00 r, , r " _;•'Thermal .; $ 8,858.00-_r- r Doors and Windows $ 8,001.00 i Finishes 441;176.00- n k1 " ` •' cal, ties_, ' ' $ .1';855.00' -A` y' f L 1 1 r riY $ 31,775.00 Electrical $-39,950.00 r - Total fEstimatedCo's- t -. - $184,448.00,- * " 1f , . i yf_ ,f off- - •` ', • I; I If there are any questions, please contact BobbnHerbulis at (407)' 323- l;f 50. , 1. { Sincerely, fi , ', r ^ W BobbYWonHerbulis - r : _ '' L i - •-a McKee Construction Co.j. j a f r' r r ^ ' 790,Monroe Road a Sanford; Florida 32771 r , Phone ( 407)- 323-1150 •Fax (407) 323-9304 -J r ' , ', r.r - r: ` ,. r r+ www. mckeego cri- CBC 048972 THIS INSTRUMENT P EPARED BY: Name: ,bG 1Jl _t Address: G.aFo¢s 3Y7'11 NOTICE OF COMMENCEMENT State of Florida 1 -7- & t 9 County of Seminole % R Permit Number: ( -7 — ` Parcel ID Number: GRANT MALOYr SEMINOLE COUNTYCLERY, OF CIRCUIT COURT h COMPTROLLER BY. 8874 P9s 1271-1272 QFSS ) CLERK'S A 2017024292 RECORDED 133/09/21317 08:05'25 RECORDING FEES $1.8.517.1 EC DLD BY hdevore I(_v- SAC- SUA-oo c: The undersigned hereby gives notice that improvement will be made to certain real property, and Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 1 \ WfSC lg S 4.6E"C SkjiFofLO FL 3a'i'1% GENERAL DESCRIPTION OF IMPROVEMENT: TEM 9111MV11M OWNER INFORMATION: Name:_ Cw---. Q%KV111ST ifA4jeciiA of SA-rlFa" Address: '3101 4.(. IiS r-LelZt oA Fee Simple Title Holder (if other than owner) Name: Address: CONTRACTOR: j Name: MC.JCL-E C43 i .+Cnur-s Cc. p/) Address: - 71)o Moa¢oE 9-4 Sl4Xf0A4 lri -"111 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: " I A - In addition to himself, Owner Designates Section. 713.13(1)(b), Florida Statutes. of To receive a copy of the Lienor's Notice as Provided in Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date Is specified) , WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. 411SW wnefs Signature Owners Printed Name Florida Statute 713.13(1)(g): 'The ner must sign the notice of commencement and no one else may be permitted to sign in his or her stead.' State of ii County of The foregoing Instrument was acknowledged before me this day of 20 / by J U ` /'// 5 Who is personally known to me Name of person making statement OR who has produced identification type of Identification produced: STEPHEN C. ESLER NOTARY PUBLIC, STATE OF FLORIDA c4mffl it FF148915 Notary Signature F cpims 11/7/2018 AM RICK SCOTT, GOVERNOR KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD I CBC1254530.-,I'- The BUILDING CONTRACTOR Named' below IS H A CERTIFIED fkg' ;r'k 4- c provisions w op ul AQn CC Expiration date: -AUG 31, 2018 N, NICHOLAS—,JdSEPHMiCHAEJ47 F__','.._,,...lMCKEE CONSTRUCTIOWC 0. 4e- .-790 MONROE, ROAD.5:. FC-32.771- ISSUED: 06/26/2016 DISPLAY AS REQUIRED BY LAW SEQ# L1606260000899 ACOR 10CERTIFICATE OF LIABILITY INSURANCE ka DATE (MM/DD/YYYY) r 05/17/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME: Doug Jones Go Artex Risk Solutions, Inc. 8840 E. Chaparral Rd.; Suite 275 PHONE FAX c 480 951 4177 uc No): 480 951 266 E4MILADDRESS: INSURER(s) AFFORDING COVERAGE NAICScottsdale, AZ 85250 INSURER A: American Zurich Insurance Company 40142 INSURED INSURER B : Oasis Acquisition, Inc Alt. Emp: MCKEE CONSTRUCTION CO. 2054 Vista Parkway Suite 300 INSURER C : West Palm Beach, FL 33411 INSURER D : INSURER E : INSURER F : COVERAGES CERTIFICATE NUMBER:16FLO75729149 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRLTR TYPE OF INSURANCE POLICY NUMBER MM/DDYIYYYY MM/D /DYYYY LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE CLAIMS-MADE OCCUR DAMAGE To RENTE-D- PREMISES Ea occurience MED EXP (Any one person) t PERSONAL d ADV INJURY GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE POLICY JECOT- LOC PRODUCTS - COMP/OP AGG SOTHER: AUTOMOBILE LIABILITY ICoEaaccdentSINGLELIMIT BODILY INJURY (Per person) ANY AUTO ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY (Per accident) PROPERTY DAMAGE Per accident NON -OWNED HIRED AUTOS AUTOS s UMBRELLA LIAR OCCUR EACH OCCURRENCE t AGGREGATE tEXCESSLIABCLAIMS -MADE DED RETENTIONS f A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTNE Y / N OFFICERIMEMBEREXCLUDED? NIA Mandatory In NH) WC29-38-687-14 06/01/2016 06/01/2017 OTH- X STATUTE 7 1 ER E.L. EACH ACCIDENT 1,000,000 E.L. DISEASE - EA EMPLOYEE 1,000,000 E.L. DISEASE -POLICY LIMIT 1,000,000Ifyes, describe under DESCRIPTION OF OPERATIONS be Location Coverage Period: 06/01/2016 06/01/2017 Client# 908-MAIN DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached H more space Is required) MCKEE CONSTRUCTION CO. Coverage is provided for 790 MONROE ROAD only those co -employees of, but not subcontractors SANFORD, FL 32771 to: r`YQTICICATr- 41A1 IIFR CANCELLATION CITY OF SANFORD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE BUILDING DEPARTMENT THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P O BOX 1788 ACCORDANCE WITH THE POLICY PROVISIONS. SANFORD, FL 327727188 AUTHORIZjE D REPRESENTATIVE 9 193a-2014 ACORD CORPORATION. All ngntr. reservea. ACORD 2512014/011 The ACORD name and logo are registered marks of ACORD n City of Sanford Building and Fire Prevention Product Approval Specification Form Permit # Project Location Address Nm wc!gr SVW V- ko 46 As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors 11 Swinging a IIKV-Ift-7 00 Sliding Sectional Roll U Automatic Other 2. Windows Single Hun Horizontal Slider Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description(including Florida Approval # decimal 3. Panel Walls Siding s s Es Bra wAa s s 3v Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name `bsc—oK A t)ICA >LA% Please Print) June 2014 Property Record Card MR Parcel: 26-19-30-5AE-330A- 0000AISEROwner: CHURCH CENTRAL BAPTIST OF SANFORD Property Address: 3101 N/ 1S I S7 SANFORD, FL 32771 Parcel Information Value Summary Parcel 26-19-30-5AE-330A-0000 , 2017 Working 2016 Certified- Values Values Owner CHURCH CENTRAL BAPTIST OF SANFORD Valuation Method Cost/Market Cost/Market Property Address 31 01W 1 ST ST SANFORD, FL 32771 i Number of Buildings 2 2 Mailing 3101 1 ST ST W SANFORD, FL 32771 Depreciated Bldg Value $2,078,013 $2,108,020 Subdivision Name, halTh5 t_t h_1 Depreciated EXFT Value $63,631 $63,717 Tax Distnct S1-SANFORD Land Value (Market) $2,551,746 $2,551,746 DOR Use Code 71-CHURCHES Land Value Ag Exemptions 36-CHURCH/RELIGIOUS(2007) Jlg5 fda•k t VaIV,— $4,693,390 $4,723,483 Portability Adj Save Our Homes Adj $0 $0 Amendment 1 Adj $0 $0 P& G Adj $0 $0 Assessed Value $4,693,390 $4,723,483 Tax Amount without SOH: $0.00 I z i 2016 Tax Bill-Arn_wiit $0.00 lar ES,Iimatof 41 - -- - Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments c Seminole County GIS Legal Description E 1/2 OFBLK33 & E 1/20FN 210 FTOFBLK34 &W1/20FN210 FTOFBLK47 &W1/2 OFBLK48 (LESS RD)&S450 FTOFW7.62 CH OFBLK34 (LESS 1 ACRESO IN NW CDR) M M SMITHS SUBD PB 1 PG 55 SEC 27 TWP 19S RGE 30E BEG 1738 FT W & 455.3 FT N OF E 114 COR RUN W 399 FT S 627 FT E 399 FT N TO BEG LESS PT S OF FIFTH ST) SEC 27 TWP 19S RGE 30E BEG 1738 FT W & 455.3 FT N OF E 1/4 COR RUN W 399 FT S 627 FT E 399 FT N TO BEG (LESS PT N OF FIFTH ST & BEG SE COR RUN W 100 FT N 160.66 FT E 100 FT S 160 62 FT TO BEG) Taxes - Taxing Authority - 1 Assessment Value Exempt Values Taxable Value SJWM( Saint Johns Water Management) $4,693,390 $4,693,390 $o County Bonds $4,693,390 $4,693,390 $0 County General Fund $4,693,390 . $4,693,390 $0 Schools $ 4,693,390 $4,693,390 $0 , City Sanford - $4,693,390 $4,693,390 $0 Sales Description Date ;Book Page Amount Qualified Vac/Imp rWARRANTYDEED J--- 11/ 1/1982 - v 01_ 25-- 074G `"1-----$ 225, 000 No -- Vacant ----- Frnd.^, on paiat:leSalc:s - Land Method Frontage Depth Units Units Price Land Value ACREAGE 0.00 0.00 7.88 $130,68000 $1,029,758 if ACREAGE 0.00 0.00 1 $108,900.00 $108,900 SQUARE FEET 0.00 0.00 353272 $4.00 $1,413,088 Building Information Is Ba_d'Sa;h :cunt mccrrect" Description Year Built Fixtures Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages Actual/Effective 2 BARNS/SHEDS 2008 5 3,050 4,900 3,050 CORRUGATED $48,916 $51,355 Description Area METAL No Appendages 1 1 i j ar Built Description Ye Stories Total SF Ext Wall Adj Value Rapt Value Appendages Actual/Effective 1 MASONRY PILASTER 1989 2 36,000 METAL PREFINISHED $2,029.097—$2,962,186 Description Area No Appendages Permits Permit# Description Agency 1 Amount : CO Date Permit Date 02657 MECHANICAL - REPLACE 5 UNITS & RELOCATE 1 UNIT SANFORD 111,719 9/29/2016 01324 REPLACE EXISTING FIRE ALARM SANFORD 2,500 4/7/2015 00321 DUCTWORK & 20 TON UNIT SANFORD 40,321 11/17/2014 01163 INTERIOR REMODELING SANFORD 254,662 3/27/2014 00615 UPGRADE EXISTING FIRE SUPPRESSION SANFORD 2,050 1/7/2014 ' 00576 GRILL REPLACEMENT SANFORD 1,125 3/28/2011 2/17/2011 00576 REMODELING RESTROOM SANFORD 91,000 3/28/2011 1/6/2011 i 02514 RE -FACING SIGN SANFORD 715 9/9/2009 02199 INSTALL FIRE ALARM SYSTEM SANFORD 30,645 7/15/2008 02128 ADD & RELOCATE FIRE SPRINKLERS THROUGHOUT THE 2ND FLOOR & NEW PIPE ON 1ST FLOOR SANFORD 15,829 7/9/2008 Page 1 of 3 (21 items) [11 2 3 L------------ Extra Features Description Year Built I Units Value New Cost I COMM: ALUM CARPORT W/SLAB 11/1/2001 400 1,215 2,600 POLE LIGHT CONCRETE 1 ARM 11/1/1989 14 14,532 14,532 COMMERCIAL ASPHALT DR 2 IN 11/1/1989 116,335 42,346 105,865 , COMMERCIAL CONCRETE DR 4 IN 11/1/1989 6.500 5,538 13,845 City of Sanford Commercial Permit Application Checklist F' D All permit application packages must be complete prior to acceptance. You must check each box to the left or indicate n/a on this submittal. A complete application package shall include the following: Ci Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number. Copy of a contract, signed by the contractor and property owner, indicating the documented construction value 2' Copy of the contractor's license issued by the State of Florida (if contractor is applicant). A site specific notarized power of attorney shall be required from the licensed contractor if he/she appoints an employee of his/her company to sign the permit application as the contractor. Certificate of insurance indicating worker's compensation insurance coverage and naming the City of Sanford as certificate holder, or a copy of a worker's compensation exemption issued by the State of Florida (must be submitted with each application if contractor is the applicant). tA' Completed, signed, and notarized Property Owner Builder Disclosure Statement Affidavit (if owner is applicant). Approval letter from sanitary sewer provider (if other than the City of Sanford). Copy of the onsite sewage disposal system construction permit issued by Seminole County Health Department for new or existing septic systems, grease interceptors, etc. (if applicable). Seminole County Impact Fee Statement. ii Five (5) sets signed and sealed building construction plans. 0 Two (2) sets signed and sealed site development plans approved by City of Sanford Planning & Development Services Department. Letter from Planning & Development Services agreeing to submittal of plan without development plan approval. This is at the developer's risk. Two (2) sets signed and sealed floor and roof truss engineering. i Completed and signed Statewide Product Approval Specification Form. f( Two (2) copies of the manufacturer's installation instructions for the following products: windows, doors, roofing materials, engineered lumber products, glass blocks, soffit materials and siding. W/ Three (3) sets of completed and signed energy calculations (signed/sealed if required by Florida Statute or code). State of Florida Division of Hotel and Restaurant approval (if applicable). A,- Florida Department of Environmental Protection Notice of Asbestos Renovation or Demolition (if applicable). P 'l State of Florida Notification on Gas Tanks (if applicable). fit Floodplain development application completed and signed if any portion of the property is in a flood hazard area as identified on the most current flood insurance rate map. THE BUILDING CONSTRUCTION DOCUMENTS MUST INCLUDE, AT A MINIMUM, THE FOLLOWING: SITE PLAN (Development plan includes additional requirements) All parking and accessible routes Accessible parking space(s) and signage details Accessible entrances Accessible ramps, handrails, guardrails, curb cuts and details t All required building exits accessible (not less than 60% if all are not required exits) Areas of rescue assistance f N Accessible signage Revised: Fehruary 2016 Page I of 7 Commercial Permit Application Guidelines 1 < Fire access r;ft Vehicle loading dj Driving/turning radius Fire hydrant/water supply/post indicator valve (P1V) Location of septic systems (if applicable) Setbacks/fire separation (assumed property lines) Utility lines (water, sewer, irrigation is Meters and backflow devices BUILDING PLAN V Construction documents shall indicate code edition being applied Rf' Page size minimum 1 I" x 17" Z Plans to minimum 1/4" scale 2 All pages numbered and labeled Plans signed/sealed and dated by a Florida Design Professional as applicable l9 Designer information: name, address, registration # on all pages V Reference the currently adopted code editions W Wind design data required on drawings per FBC 1603.1.4 to meet 129 mph ultimate design wind speed for risk category I buildings, 139 mph ultimate design wind speed for risk category II buildings and 149 mph ultimate design wind speed for risk category III and IV buildings Ultimate design wind speed (Vult) Nominal design wind speed (Vasd) Risk category Exposure category Enclosure classification Internal pressure coefficient Component and cladding design wind pressures in terms of psf Structural Calculations, if necessary Threshold Inspection Plan (for threshold buildings) Ci All areas dimensioned and use noted Gd' Corridors Shafts and elevator hoistways Stair location/guardrails/handrails Partition denotations and schedule E Door locations, sizes, door and hardware schedule Window locations, sizes and schedule Tempered glass locations Attic ventilation and access C,a Air barrier requirements Fie( Interior finish ratings and schedule V Light and ventilation Sanitation Elevators Escalators AP Lifts Roof coverings Construction type design criteria: R( Type of construction denoted (per table 503) 52( Occupancy group classification denoted for building and rooms/areas Ge Gross square footage — Net square footage calculations Revised: February 2016 Page 2 of 7 Commercial Permit Application Guidelines E' Building height 5Percentage of exterior openings calculations Ak Classification of hazard of contents (if applicable) Structural Design Criteria: Q' Ultimate design wind speed (Vult) G/ Nominal design wind speed (Vasd) 2' Risk category V Exposure category 6 Enclosure classification Ci Internal pressure coefficient Component and cladding design wind pressures in terms of psf Structural Calculations, if necessary GT Floor loads — psf Stair loads — psf Roof loads — psf Balcony loads — psf Corridor loads — psf Storage loads — psf Materials to be reviewed shall at a minimum include the following: 9 Wood / grade — species d Steel / type - grade Ci Aluminum Gd' Concrete E Plastic v* Glass Ok Masonry C/ Gypsum board and plaster 2 Insulating (mechanical) 48 Roofing 9 Insulation Alternate materials Structural: 0 Signed and sealed soil report with a positive conclusion required A Compaction requirements Q Foundation locations, dimensions and depth specified 46 Foundation denotations, schedules and details Reinforcing steel, amount, size, grade, spacing, and lap specified l Footing dowel locations Maximum filled cell spacing Embedment' s ik Slab thickness and reinforcement Vapor barrier Termite protection Relieving arch steel details at pipe penetrations Brick ledge detail including flashing and weep hole size and spacing E Building materials used tP Lintel locations, denotations and schedule Cd' Exterior and interior structural wall sections G Columns Revised: February 2016 Page 3 of 7 Commercial Permit Application Guidelines Tie beams iv Structural steel size, type, connections Framing details and fastening Load path connectors Floor deck and fastening V Wall sheathing and fastening iN"` Roof deck and fastening EIA" J Stair construction Cd Window and door details, including design pressure of openings G Fastening details for windows and doors, (type, length, and quantity) Exterior mounted mechanical units fastening methods to meet wind load Roof and floor framing, truss layout, connector schedule Fire Protection Requirements: Fire separation requirements for corridors, elevators, stairways, floors & shafts E Occupancy separation requirements V Tenant separation requirements 56 Fire resistant protection details for type of construction V Rated requirements for walls, floor -ceiling and roof -ceiling assemblies LZ Design numbers and details for all rated assemblies V Design numbers and details for all rated penetrations @I Rated door and hardware schedules 19 Fire blocking and draft stopping t Calculated fire resistance d Interior finishes (flame spread/smoke development) Life Safety: Rf Occupant load calculations and egress capacities Special occupancy requirements C Egress plan d Number of exits 0 Capacity of exits 9f Arrangement of exits C Travel distance to exits/common path of travel Stairs construction/geometry and protection Horizontal exits/exit passageways Ga' Illumination of exits V Exit signs Emergency lighting Enclosures v& Handrails Guardrails Ramps 40 Early warning systems schematic v4 Smoke control systems schematic Stair pressurization systems schematic Extinguishing requirements Areas of rescue assistance Accessibility Building: R' Door sizes, hardware schedule lid Vertical accessibility Revise& Fehruarv_ 2016 Page 4 of 7 Commercial Permit Application Guidelines G Accessible route dimensions 2' Maneuvering clearances 4 Hi-Lo drinking fountain i Equipment clear floor space/reach ranges 4 Areas of rescue assistance A Signage All ATM machines Accessibility Restrooms/Bathrooms: ld Turning radius d Required floor space for fixtures G7' Fixture and equipment mounting dimensions 1W Adaptability Accessible requirements for special occupancies in addition to general requirements will also be reviewed. PLUMBING PLAN 11' Plumbing plans submitted Q' Piping materials 9 Piping supports C Determine minimum plumbing fixtures required based on occupant load calculated per FBC 1004 G Water distribution diagram 2' Water hammer arrestors V Plumbing drain, waste and vent riser diagram Or Grease trap detail Aff Grease trap Health Dept. report on existing 40 Interceptors Roof drains/calculations for flat roofs Backflow prevention Medical gas Oxygen systems Environmental requirements Water Heaters: E T & P drain C Air gap d Pan drain - GI Thermal expansion device Lei Heat traps G/ Mounting platform GAS PLAN O' Type of gas imr Gas pressure Appliances schedule and BTU's 9 Chimneys and Vents Off Combustion air i LP tank size and location (above or below grade) Protection requirements Gas Riser Diagram: i Pipe type Pipe sizing Revised: February 2016 Page 5 of 7 Commercial Permit Application Guidelines 4 Total developed length O` Segment lengths 4 Appliance locations Shut -offs valves MECHANICAL PLAN d Mechanical plans submitted C Energy calculations G Duct systems and sizing C( Duct work clearances at mechanical room (4" minimum) CAI Duct supports d Means for balancing HVAC system d Diffusers (size and direction) C CFM requirements d Ventilation d Combustion air CJ Outdoor air calculations d Balanced return air d Make-up air d Equipment location and working clearances ( 30" wide by 36" deep, 6' high minimum) V Condensate piping and disposal F Required platforms and catwalks Roof mounted equipment (including equipment and curb anchorage) Details and specifications 2( Equipment sizing calculations Ga( Equipment specifications G Joint sealing methods and product specification A Air balance table R Rated penetrations - fire damper details and manufacturer's installation instructions JP Means for automatic fan shutdown Kitchen hood, duct plans, fire suppression and specifications Bathroom exhaust systems Special exhaust systems Chimneys, fireplaces and vents Other appliances Boilers Refrigeration Bathroom ventilation Laboratory ELECTRICAL PLAN 9 Maximum available fault current at service d A1C rating of equipment Ld Voltage and phase of electrical system Cf Load calculation Gd' Electrical service riser diagram indicating overcurrent protection sizes, conductor and conduit types and sizes, number of service disconnecting means, grounding electrode system: bonded to the foundation steel, structural steel, metal piping, size and type, separately derived system or not? (solid neutral or switching) Transformer sizes and types if used Q' Panel schedules and ratings Power plan C( Panel locations and working clearances Revised: February 2016 Page 6 of 7 Commercial Permit Application Guidelines GY Lighting plan U Device legend CQ' Wiring methods and materials d Feeders and branch circuits, conduit sizes and types d Grounding conductors Ga' Exit lights d Emergency lighting G Egress lighting if Signage and disconnecting means location 4 Generator type: emergency or standby iP Remote annunciation 40 Load shed (if necessary) Ed Required receptacle outlets d GFCI's Equipment Special occupancies iW Emergency systems i !w Communication systems 0 Low voltage FIRE PROTECTION/FIRE SUPPRESSION PLAN AP, Early warning smoke evacuation and control AV' Sprinkler design criterion (separate pen -nit required) 4' Fire alarm design criterion (separate permit required) Pre-engineered systems Riser diagram Standpipes These guidelines were compiled to assist the applicant in preparing a new commercialpermit/plan submittal and may not be complete. The applicant is required to meet all City of Sanford, state, and federal code requirements. Please be aware that a separate permit is required for any fire sprinkler system and fire alarm system. All site related signs, fences, hardscape features, guard/hand rails, free standing walls, retaining walls, canopies, accessory structures, site electrical and lighting, satellite dishes, dumpster enclosures, irrigation systems, lift stations, and any demolition of structures. Revised: February 2016 Page 7 of 7 Commercial Permit Application Guidelines Locke Bowden, P.E. Metal Building Supplies FL ,5365 9450 Alysbury Place 800 E. Donegan Ave Montgomery, Al 36117 Kissimmee. FL 34744 Quality Assurance Program: Keystone Certifications Category: Structural Components Sub -Category: Structural Wall Code: FBC 2014 51h ed.; Sections.,1,709.2 Method 2-B Description Subsirale Desian Uplift Pressure* FwtenNs 1 PBR 26GA Wail 16GA steel framing 47.5 psf fastening 1-1/4" tall rib Corrosion resistant: B12-14 HWH SO with Open Framing Must be designed In pattern 12"-12"- at 12" O.c. sealing washer or approved equal at 12"- 36" width compliance with FEC 12" @5'•0"o.c. thru fastened 12"-12" fastener pattern. Panel side laps 80 ksl 2014. fastened with'.-14 x 7/8" HWH SO with Structural t60.0 psf fastening sealing washer at 2W o.c. Paint finish Non-HVIIZ pattern 12"-12"-12" optional. O 5'-0" D.C. insulation, manufacturer's approved product (Optional) Install per manufacturers details and in com (lance wlth FBC 2014. Design Pressures Includes safety factor=2.0 ALLO}YABLe UIRORM LOADS IR POUNDSPOR EOUARC FOOT 2_ OAU01 PD - sPAti LOADTY e S A INFeer TYPE aVtOL N yATIVE WINDMAD - 6 - e9:0 _ 34 e 9.1 14 7 41 - 0 PU41TWE D "-' NaaAT1Va WIN LOAD as _ _ 1103 501 1 7E•4 33 d 70S 4 24.6 2 6 203 20 - 159 12.6' 1 100 ' 2•ePAN Vy ID LOAD:-:= 672 49.0 3 1— 301 214 0.2 Ira 10 J25 NEO rrVEYNDLOAD 654 027 44.0. 37 476 J 213. 1024 1 ,73SPA11y^ r4-SPAN N E..*f1-0 Cylljl- 797 Sa. r 440 354 T 2 19 a Jiid _^ P.O3mve ID.LO 0 7 1 57-7_, `; r=L13' I 2.5_,` yd.G- 19a o_ _' 140 Based on ASTM E 1592 Testing 8 84-0284T-08 AB fl tiltyReportflStandardYeai Force Engineering and Testing (TST-5328) A 84-0284T-OBA,B ASTM E 1592.01 (20051) Force Engineering and Testing (TST-5328) Load table 1. ASTM E 1592.01 teststondards are equivalent to ASTM E 1592-05 test stondords. Limitations: 1. Underlayment to be compliance with current Florida Building Code. 2. Minimum slope to be In compliance with Florida Building Code 2014, and in accordance with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3 4. Fire classification is not part of this acceptance. 5. Shear diaphragm values are outside this report. 6. All support framing to be In compliance with Florida Building Code 2014, Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading. 7. Engineer must evaluate the wall panel attachment to substrate for fastener pul(out/pullover per AISI Specifications. ' 8. This report (foes not imply warranty, instaliation,.recommended product use outside of this report. Compliance Statement: These products herein evaluated by Locke Bowden, P.E. have demonstrated compliance with the Florida Building Code 2014 with referenced documents submitted. Certificate of Independence Locke Bowden, P.E, does not have, not will acquire a financial ljiterest In boy cotnpaii 0t*,6rdJ!s(rlb.U(jng products under this evaluation.G Locke,Bowden, P.E. is not awned, operated or controlled by any compagy matnUtirJ.P gtD r2l3l tii fg gaducts under this report. 4T1r• " j Jfi.04 i. FiorlSfa Qg. No,e4%Q30F t.Ilk,! oo oo 0NN- 141111110 r PQR YVA..L PANEL 12' . 12' tf of X 7/0 LAPICK j12-14 x 1 1/4' RMI w/ WASHER. 12'-12'-12' PATTEIIII FASJ KL A N_i4$J1ITER{OR SUPPOOM 1/4-J4 X 7/0 LAPIEK n 20 D.C. 12-14 x 1 1/4' RAN w/ WASHER, PATIEAH IE65jKLEB P 41TERN FOR PANEL ENO AfiQ PhNEI AID U PS Drawing provided by Force Engineering and Testing AL-FQROOQ CORPORATION CONSULTING ENGINEERS & PRODUCT DEVELOPMENT PRODUCT APPROVAL. EVALUATION RULE CHAPTER #61 G20.3 • METHOD 1 OPTION D FL 17900 Date: 7/16/2015 Detailed Product Description : Manufacturer: TELI. MANUFACTURING, INC. Manufacturer Address: 18 RICHARP DRiVE. LITITZ, PENNSYLVANIA 17543 Model Name: "TELSTAR/TIOGA/SPARTAN" OUTSXMING STEEL DOORS SYSTEM, Maximum Frame Width: 541 8" - Maximum Frame Height: 981 8" Maximum Load: +75 PSF, -75 PSF (Large Missile Impact) Installation Drawings 1115-35L J This product complies with the High Velocity Hurricane Zone (HVHZ) testing requirements. Comparative analysis used _Yes, X No Mandatory Tests (Tested in accordance with TAS-202) ED, 011 i1',.-, T' '. g -^i't - `t ASTM E330 Uniform Static Hurricane 07/10/2015 HETI-15-5069 I Rafael E. Droz-Seda, P.E. TAS 202 Air Press. Engineering & 07/10/2015 HETI-15-5070 Rafael E. Droz-Seda, P.E. Testing Inc. 07/10/2015 HETI-15-5071 Rafael E. Droz-Seda, P.E. Suimlemental Tests (Tested In accordance with TAS-201 and TAS-2031 ASTM F.1886-13a I Large Missile I Hurricane 07/10/2015 HETI-15.5072 Rafael E. Droz-Seda, P.E. ASTM E 1996.14 Impact & Cyclic Engineering & 07/10/2015 HETI-15.5082 Rafael E. Droz-Seda, P.E. TAS 201 & 203) Testing Inc. Under the limitations of the attached Installation drawings, to the best of my knowledge and ability, the above window/door product conforms to the requirements of the 2014 Florida Building Code. Evaluation Report Engineer: I,++*r,' au; n; lavad Ahmad PE 1170592 No yo6ez AI-Farooq Corporation EB 113538 . 37{YP OF Jul 16 2015 6:19 PM Doors 1235 SW 871" Avenue I Miami, FL 33174 1 T: 305.264.8100 1 F: 305.262.6978 1 +v,v+v.afcena.com I alfarooa@afcenexom DOORS ARE RATED FOR IMPACT. INSTALLATION OF TEAS PRODUCE N THE HVECL AREA DOES NOT REOURE THE USE OF APPROVED SHLMERS OR EKJERNAL PROTECTION DES COMPLYING WITH HVHZ REQULAM4ENM INSTALLATION OF 7HE5 S'S'MAH OUTSIDE THE }M2 AREA SMALL MEET THE APPLICABLE REQUIREkIENM FOR WWD BORNE DEBRS PR =071`*tL TFJ.STAR/7T0GA/SPARTAN" OtTP 7WrN . SL'EEL DOORS APPROVAL APPLIES TO SNdi (X) %ZAF DOORS MTMOUT SlDaXrM DOORS NOT APPROVED FOR DISTAWROhS WHERE WATER MZrA=N h'F =A.\'OE 1S REOLITUA. TICS PRODUCE HAS BW DE== AND TESTED TO COMPLY WITH THE AE7]i1D ENES OF THE FLC=A BUQD?.'O CODE TI WNG RICH V=CDY MMWC ZONE lima). WORD BV= Sf OVUM WtW Be ANCHORED PROPERLY TO TPANSFE R LQADS TO THE STRUCTURE ANCHORS SHALL BE AS LISTED. SPACED AS SHOWN ON DEWS. ANCHORS 040MM TO RAM MATEIM V LL BE BEYOND WALL DRFSSIFIG OR STUCCO. ANC HOFItV OR TRADING CONVIDDOIS NOT SHOWN N 116E DEIMS ARE NOT PART W THIS APPROIVAL A LOAD WI M'TON NCFEYSE IS USED IN MW OF ANCHORS INTO 'HOOD MY. ALL SH= 10 BE MICH IMPACT M\%-UEOLL: JC AND 1,ION-COMPRESSIML UkTOWS NCWDNC BUT NOT LOAM TO STEU,'METAL SCRF,M'THAT DOME INTO CONLWT WIN OTHER DISSULAR WA-MALS SHNL MEET THE i EDUF ENTS OF THE RORMA WIIDWC CODE MAVTJFACNl--7"$ V3M SHALL BE LOCdED ON A READILY V=r I9CATION N ACCORDANCE WITH SECTION 1 OAZ OF R R10A MXDINC COOS LABELING TO COMPLY W1DH SECDOH 1710AZ DOOR OPNDlH s G. WIDTH - loct La 3' MAXAX TdATL TUMR OUTSWING SINGLE STEEL 000RS ( X PC - +bo.o PSF (ETCEFRIOR) 0 PSF (INTERIOR) it 19 NOTE. ECRM REQUIREMENTS TO BE REVIEWEO BY AHJ A-TG sRDouer e+auw.sK DocvrDa vrw .71,'PAIm ,.,Ec o+wmt a cwaoD AMD DDc Mor rnomc LaDRUNgPI roR A ac asrw no+ccc >,.. wlcx oIc xc WImDgI.: oomTe rRaM x z7. s-CONa 4C= TO PC RCWM 3 FM'PC 31= M PUICK= AM G,t]ADOM or im PROD= D.= ON TPC MOD= FYALOA710M FMN= Mtge D= MOT ov= Ntol TPIC cmcmo c DCARm O•-Vc PRO = ap"w" DomueT ".L DC M=V= MAD I< Am= Df Aw 1954= PAONW-- =44L CC FWAICD Vf A nZMA VkiKTR OR AMC= *= ILL OMUC VC D4= Or LO 0 =JO TOR T+a PAW= AND WHO WILL PC Its 70R 7Mc P"*M or vc P= 0Za4Mt Or PMCOR9. ACM= AM A D6CCAT19 NZ .0 TIC IMIX 12CNL17' 7611 SII W TO 'H* IA= 7TIC .'DL V== mew=.. RR MINX D-•D4 1im OWL DM 7MC MM A)* OWN'L =L NO ap== OI DR rxcrc; AND. Dcud . P sxcORO 7wr PIMA= C U z • 2 T: M m0, e J Ca O5 Uo wn 0<i8 0.0 NmJ Q W n lLSJn R JP• Q W"2. I FL #17900 4 Wo.7019i2 r T I AL 5-35L Swot t oY I T r FRQ 114, JE WVTH 4 om o& .—I V.l I ........... N ................. 4 .4 LMMAx MAX MQQAZSPARTAN" OUISWINQ SING MEL DOORS ( x Pd - +75.0 PSF (DaMM) 7&0 PSF (MEMO) z FRAME MM 0 0IL n: 0 01Too gll U. p C3 T . .... ...... / .... .. WN, z nOGA/SPARTAN- OM -WING SINGLE STEEL DOORS— ( X Pd - 400.0 PSF (EXTEFWR) 50.0 PSF (DfnD;UOR) FL #17900 I SECTON A -A 10x1}' SDS SECTION EE-B i ftw-um i -. alASONRY rr F- SE=N C-C SECnM D-0 TYPICAL ANCHORS AT WAD/U=/SnU fS DIA, 2m MTO 2BY WOOD EA=G OR wood STRUCWRES 1-11r WL PENVRV= D1T0 ,HOOD A/16- M& TTW TAPMN O .123 KM Py M 130 WO = WOOD BUCKS OR W000 STRUCTURES DGiF>;'T.Y wm i -3= PSI CONCRETE. 1' WN. EDGE DIST. 1' UK EUM DiTO COXCRM 0CAD/44J%W/SW 3/16' DIA. ELCO ULTRACON (r"M XM "13* K* WO = WOOD DOCKS OR WOOD STRL'CiURES 1-1/Y JOL PfliETRa= wo WOOD DV=LY NM 1dm= PSI CONCRETE 1- WX EDGE Mr. D=MY DRO 19'-Z p PSI 1 4wm mom 1' UK EDGE owl 1-3/!f• 1K DJ9M DTTO CDNCWM (W.AD1JNA?.1SlW 1-1/4' IM MW DRO GROUT RLLED BLACK (41 M TELSTAR SERIES SINGLE STEEL DOOR gSiElut FL #17900 E4 Z X LA aw ,g no, a Z Y Qt xa a a A Q 71 W V a o`is8 0T3 D9 DEWL A Q+.Co i d' T D aQWwCSr Ot 10^ 0. Q ,Nc C cUO2 to S¢O C d d U . z? oZ£ 02J 013 4 1- J r W 03 8 Oi MAL B w° DR 3068 PRO DEL RHR Wf 10- X 10- OW FL #17900 Nt.7aflC O i S i TELSTAR SERIES SINGLE STEEL DOOR SYSTEM i 5-a5 77f00t 4 Ot REALNu PARE NWE#R DES( YN1ESiUL OSY. D1 NN020702 DIO[ 50aa 20CA tat DB t OZ MM07030Z tEla'7AR DOOR FRAIE SLEAOL7:/JN®S 27a' x 673' x 0.0a4' ttaC taCA W.VADWEAI STEEL r I I U, rsso ow•n Noma FOG **I& YEI_STAR H&DER t i V a ora u. rtw na %M O o O e v O. HINGE RMNFORCEMEM DOOR AND FRAME 7 CA 1 1 i 11. nar. wwown lo,.57AR HINGE JAMB r y J STAR T,iRMOLD FL #17900 ow-0 Im All* TIELSTAR SERIES SINGLE STEEL DOOR SYSTEM S 15-35L 24 V I ti 7 ZZ za 2 0 0 0 g 0 0 14 2 0 0 0 h- r O JX L o 0 a o s s O O C7 g g;<o a 0 0 T 001 oocwz zi 9 j Q Jai Q •• 5^ SECTION E-E 2 t gz a 6 75 SECTION C- c 5 SECTION H-M tV30114OWZONTALSrROa` SECTION 3 1 is 21 A l2 I SEC.ION F-F 4 JW VERTICAL CROSS SECTION 11 a° FL #17900 TOGA/SPARTAN DOOR ME 'TA11 SERIES SING[ E STEFL DOOR SYSTEM h IJIS'. ail SEE NOTE 2 rrx.. • .aism RDANo_PAT. owcgK10x t OTT. xEADER 7RAVC 2 x 0.030 THIL 7GG GALVkNmkAL STEEL 1 2 ISMA CALVAYAIEAL STEE, 1 It W63-73 ALUMNUM 1 t ,• t • T14K. can 1:r• 6 CALY 1 6 I CALVANKCAL 1 7 1 AM 1 GLLVANNEAL STEEL 1 a n4t CALVANDWAL STE= 2 7 1 16DT0091 CAPK021CJIL LOCK RVKFORCEMDIT 1.W Y &ar x 3" x 054- 7W, 16CA COLD ROUM SIM 7 70046 FRY,IF o ' Y t , GAL SIE1:1 2 70007 O0 Y Sh. 1 I R• OAM 1 10043 CALVANNCAL STML 2 tOOUC 14040SE LOOP 3.00• x 1 0' Y t7.4 Y 0.0W' TN1L t3CA. COLD ROLUD 72= KF JAM M TRAM CALVAI•WOIL STLAL T U x 1' DTS 04G =RF*% ST7a. fNMMOI-0111* K I 1 CALVANLAL ST 2 O 1 0003A 1f.V0E 4-1 AIONTp'C LOCK NM`OW OPTION ,T0223a 1 W N 1 10203 1 aow7 a ALLUNW 1JAMBD9n9l2ONASSlD4®.r 16QL CwWNU_ 12G 6 CALVMPIEAL. STEEL 4 a'• TO T • v 2-1/A- DYNAROLT XWD ANCmOW VOR CONCRiTF 21 I IleT 1 • • A T STUL 24 23 SI M 12 26 1 Ira Tp 1 • KFXNTJT F TO MATCH rmd 12 27 410 1' ! STEEL tl 2tl KZ RATE - TO MAtcm OPTION AS SPT0 ww 1 2D 12 - 7A x 31V PKWPS FLAT HXAO ODl1N[I. 1C( MACHOS SCREW STUL FOq MNGES SIM 32 3 tf • Y 1 7 A MURS RAT HEAD CCUM}3=.0 TAP= CON ME SCRflv STm 3 34 0300 MFAW OK1TY 00 1 RM PAMC W TRM 1 32 T6•• T 1 • ,- a- W W1. T N (NOT A 33 MCSMOWI 1 , 1 a• TMK. COLD ROLLED 5r= A d4 C010000 T 1I COLD HOLLER 33 OOM L=00. J 2 t AOHZ3l KM-C64U- lT= UT ftNOVA7NC iLASw "TSf9 1NCL NO XUAN2 36 MOO= BUT ERPLY ANO,OR T36' x 2.5V x 7.00• Y 0.046- TWL cZLF=-=sTzn 4 37 SOIDOW ANCHOR O.W Y 2.OY Y 7D0' Y omr rg,,- COIO F.O= STM 4 36 1 4- x 3 ' HOC WAD MACHINC COLTS ANO LOOK NUTS THRU FRANC CUPS STEEL 2 x 3 1/2" NAILS SIE0. 6 40 3 x 6' WOOD LAG DOLT STCEt 4 1) FOR AITCHOIDNC XIM DOW FRA1C Ma AWB TD FCAAC XMX -146 AND FFYC SDL1R JA14 1Mk WV 1DL) MM MUM = (2 PR WO 1/C 70 1/2- DNMODL =n BW YON WING = F LOC 4 KM 6DU 10 W OF SUMO M tD= TO A00E,'E 3-M40M UL M W= AM LOGOS AND AtK = AS Wn IN otrar:sc owcsml m ME7u n FOR AA"CO AM DLi WN A'474LY TO IWA. WQ `,. M "WD4 MCC AM S= IA= USE (4 PER Q4NT7L'U i12 OR LAICZ']: DMLNG 9G l , OF ASFXVU LET= 70 AD= A'-- T Z DQ D09+D +V+PIDD QW.TIDS LDCATC A?Z ANOW 4 Sf10.01 19 A" DCI'f:l90iK 3) MR ANUMC ROOK 6ATc Al= Or FWM L.NCC AND ^wit70: awn am O ND= = CL M 443/r 70 1/r W=M W= W= OF MFFXW UN M 1D A09M 30WX Dommw NTO CONOfCR TIRN 4 1/r NDLLUM D10E MONCL OR (2 PM =0 3/1r -m :/r WAM RX 1<loo NW 7AF00lI SCRE3TS OF SUFF10E16 1SNGM 70 A*" 1-0/4• )CaDIM O=MW 030 CONO =11DM.3-3/:C A"N ED= DWJ= (ADD %0= F 143> M 1AGA7Y AKD A72 = AS St M N RAON 09 AISLL OCDLT. UWCM U= K -D A 1CKt W DDOMMOU DIN G IM2-4/r W IM 9G E AS SM N at== AND DOPURM CCU& 3) DSDu= K A =am AND wjv9 314+1L se wm= D+ AKFOFSM= vmI ERLRJF=xw.- 2SDuI9MV NSO4ICTDN' AND S WI NOT YC C= N aWrFA= wrM =09M L='*M MC 1/OOM + 7>3 47H SPECF0 eCA.e A 3La 1RALONC 16CL (,OL>r' LTL) L CCt:T.DC EfWM COLON Am STREM3N 3= FST. E TIOGA/ SPARTAN SERIES SINGLE STEEL DOOR SYSTEM FL #17900 1ft 15= 35L Wr z •Y of Sd 7_209 ' Ml' = ° O V p ". w ? _ 7Aor I O e"c i7Q1Spa , QWm o•° p . LL y r6 _ j Q AY Y 615' SR1.006 C.S z H n 2125' SSl' 2125' S S 75' R w 37/6 r•rt JC, QL a x }- r T 1JI Z I,a- , o am 3 to Q 1 J 4 • • I - o FL #17900 a —1 2 %s 000s .g .wr , l4 00°¢ M nK s V m A=Mdw. 'ROGA/SPARTAN SERIES SINGLE STEEL DOORSINGLESTEELDOOR S 5 3/4' 8 7 1.214 23/32 43/64FTf21/8 -- 4 ---- • 2 1/3 — i 1 6Gk WIDTH WRftS FRO{ 4 7/8' TO 12 1/4'. DOOR CHANNEL 5 3/4' FRAME SHOWN 20G4 TOP CA? O,,D6 5 3/4 6063 ALUMINUM THBESFIOLD fO.1 QEVHIMM- ) 4MOrCC 11ONNRCa1D 4 I 5 — i 27/64 1 45/64 18GA ' AOTTOM DCQR SKIN 1/8 5/16 —! — 18G4 TOP DOOR SKIN 7/32 17/ 59/64 3/4 9/16 n JAMB MSkMERSTRMMQ WIDTH VARIES FROM 4 71C TO 12 1/4', 4 7/8' FRAME SHOH'N. DRYWALL FRAME WIDTH VARIES FR04 4 7/8' TO 12 1/4 , 4 7/8' FRk%E SHOWN. 1t 14C = 2r 7llX / `{ yyt.ay 1 aKr zwmm ImOR WAAC =w. T ml cCC27C camx. rr ACIC my AMOK; Ur 0=-3*r=0 o-emo= LO= azm iK Ram Am x aim i1FOMCOMRF = C7C QR COMB NFO ANCHOR o DENSITY. 0.733 T3/R rFP -a o Lca c A7 zr ClC LAIL LOQCiot PLfw a cam acim fiS cot PROJG== 1rCM0 57JLM MOOR 35 0 •aaao m nwt AOI APK= S1 CROS= PAMM PRDF ,O .SPAC.Z=. C= EP= PAYS A R i . vri H= c 19OOD 911w= MQC APPLY PO. NL SPM 3" V% ooa A WWCPMW V= =CMOaVNU FL # 17900 1D ORDOORLEAF COIN / /t O O PIPE AND STRAP ANCHOR . t s , A i AT 2r Mt IOX ASSEMBLY om K w DIw com; RIl= S Mr; MY ANCHOR = N0.70sI2 31V: V= bGk zin CCH QMMQ •Q W= 1- 1/r nM Cunt: 7ACW r AIAn O •. a a TIM/SPARTAN SERIES SINGLE STEEL DOOR SYSTEM tiar.•o R't 2 f o Ila NIX 1? n° I; I. mcwmq no. 15- 35L Florida Building Code, Fifth Edition (2014) - Energy Conservation ; EnergyGauge Summit® Fla%Com-2015, Effective Date: June 30, 2015 C, IECC•2012 - TotafBuilding'Performance Compliance Option Check List A lications for compliance with the Florida Building Code, Energy Conservation shall inc This Checklist The full compliance report generated by the software that contains the project summary, compliance summary, certifications and detailed component compliance reports. The compliance report must include the full input report generated by the software as contigous part of the compliance report. Boxes appropriately checked in the Mandatory Section of the complaince report. EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 1 of22 PROJECT SUMMARY Short Desc: Youth Building Description: Central Baptist Church Youtt Owner: Addressl: City: Sanford Addressl: State: Florida Zip: 0 Type: Office Class: Renovation to existing buildi Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Conditioned Area: 4201 SF Conditioned & UnConditioned Area: 4201 SF No of Stories: I Area entered from Plans 0 SF Permit No: 0 Max Tonnage 4 If different, write in: Compliance Summary Component Gross Energy Cost (in $) LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? Design 3,611.0 Criteria Result 4,162.0 PASSED PASSES No Entry PASSES No Entry No Entry No Entry Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit@) Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 2 of 22 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Adam J. Barney Building Official: Date: 0-01 -11 Date: 3 Z 1 certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Adam J. Barney Reg No: 69124 Plumbing Designer: Reg No: Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 3 of22 Project: Youth Building Title: Central Baptist Church Youth Building Type: Office WEA File: FL_ ORLANDO_SANFORD_A[RPORT.tm3) Building End Uses 1) Proposed 2) Baseline Total 229.80 311.20 3,611 $4,896 ELECTRICITY(MBtu/kWh/$) 229.80 311.20 67366 91182 3,611 4,896 AREA LIGHTS 21.80 52.70 6395 15438 343 829 MISC EQUIPMT 63.00 63.00 18465 18465 990 992 PUMPS & MISC 0.20 0.20 63 54 3 3 SPACE COOL 49.50 77.50 14502 22708 777 1,219 SPACE HEAT 3.60 3.50 1059 1030 57 55 VENTFANS 91.70 26882 1,441 Credits Applied: None Passing Criteria = 4162 Design (including any credits) = 3611 Passing requires Proposed Building cost to be at most 85% of Baseline cost. This Proposed Building is at 73.7% 114.30 33487 1, 798 PASSES EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 4 of 22 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP W/Unit) or No. of Units (W) (W) Sgft or ft) None __Jj Project: Youth Building Title: Central Baptist Church Youth Building Type: Office WEA File: FL ORLANDO SANFORD AIRPORT.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID sq.ft) CP CP ance Meeting Rooms 15 Conference/meeting (Multiple 1,761 l 1 PASSES Functions) Multi -Purpose 15 Conference/meeting (Multiple 1,452 2 1 PASSES Functions) Multi -Purpose 15 Conference/meeting (Multiple 988 2 1 PASSES Functions) PASSES EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 5 of22 Project: Youth Building Title: Central Baptist Church Youth Building Type: Office WEA File: FL_ ORLANDO_SANFORD AIRPORT.tm3) System Report Compliance AHU-1 System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 48000 18.00 13.00 11.60 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 17065 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1600 0.80 0.82 PASSES System -Supply Constant Volume Air Handling Air Handler (Return) - 1600 0.80 0.82 PASSES System - Return Constant Volume AHU-2 System 2 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 48000 14.00 13.00 11.60 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 17065 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1600 0.80 0.82 PASSES System -Supply Constant Volume Air Handling Air Handler (Return) - 1600 0.80 0.82 PASSES System - Return Constant Volume AHU-3 System 3 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 36000 14.00 13.00 11.60 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 17065 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1200 0.80 0.82 PASSES System -Supply Constant Volume Air Handling Air Handler (Return) - 1200 0.80 0.82 PASSES System - Return Constant Volume EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 6 of 22 PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Water Heater Compliance Description Type Category Design Min Eff Eff Design Max Comp Loss Loss Hance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance linchesl Runout? Temp [Btu-in/hr Thick linj Thick [inj IF1 SF.Fj None EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 7 of 22 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of Energy and Pacific Northwest National Laboratory. Adopted with permission Topic Section Component Description Yes N/A Exempt 1. To be cy-Design ,heckedberor Engineer Fenestration C402.2.7 Envelope U-factor of opaque doors associated with the building thermal envelope meets requirements. Insulation C402.2.1 1 Envelope High-albedo roofs satisfy one of the following: 3- year-aged solar reflectance >= 0.55 and thermal emittance >= 0.75, 3-year-aged solar reflectance index >= 64.0, initial year solar reflectance >_ 0. 70 and thermal emittance >= 0.75, or initial year solar Wattage C405.6 Exterior Lighting Exterior grounds lighting over 100 W provides >60 Im/ W unless on motion sensor or fixture is exempt / from scope of code or from external LPD. Wattage C405.4 Interior Lighting Exit signs do not exceed 5 watts per face Wattage C405.2.3 Interior Lighting Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. HVAC C403.2.6 Mechanical Exhaust air energy recovery on systems meeting il TableC403.2.6 SYSTEM — SPECIFIC C403.3.1,C403.3.1.' Mechanical Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. / SYSTEM — SPECIFIC C403 3.1,C403 4.1 Mechanical Water economizers provided where required, 0] meet the requirements for design capacity, maximum pressure drop and integrated economizer control. SYSTEM — SPECIFIC C403.4.1.4 Mechanical Economizer operation will not increase heating /R El energy use during normal operation. SYSTEM — SPECIFIC C403.2.10.1 Mechanical HVAC fan systems at design conditions do not 4/ exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM — SPECIFIC C403.2.10 2 Mechanical HVAC fan motors not larger than allowable limits. m SYSTEM — SPECIFIC C404 2 Mechanical Service water heating equipment meets efficiency requirements. SYSTEM — SPECIFIC C403.2 3 Mechanical Centrifugal fan open -circuit cooling towers having combined rated capacity >= 1100 gpm meets minimum efficiency requirement: >=38.2 gpm/hp Air Leakage C402.4.7 Envelope Vestibules are installed on all building entrances. Doors have self -closing devices. Insulation C402.2.6 Envelope Slab edge insulation depth/length. Slab insulation 0- extending away from building is covered by pavement or >= 10 inches of soil. Plan Review C103.2 Envelope Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/ l /20 l 7 Page 8 of 22 Plan Review C103.2 Exterior Lighting Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Wattage C405 6.2 Exterior Lighting Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Plan Review C103.2 Interior Lighting Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices HVAC C403.2.5.1 Mechanical Demand control ventilation provided for spaces 500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. HVAC C403.2 4.3 Mechanical Each zone equipped with setback controls using automatic time clock or programmable control system. Plan Review C103.2 Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed Load calculations per acceptable engineering standards and handbooks. Plan Review C103.2 Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. SYSTEM —SPECIFIC C403.4 5 Mechanical Zone controls can limit simultaneous heating and cooling and sequence heating and cooling to each zone. SYSTEM —SPECIFIC C403.4.3 1 Mechanical Three -pipe hydronic systems using a common return for hot and chilled water are not used. SYSTEM —SPECIFIC C403.4.3.2 Mechanical Two -pipe hydronic systems using a common distribution system have controls to allow a deadband > 15 OF, allow operation in one mode for at least 4 hrs before changeover, and have rest controls to limit heating and cooling supply temperature to < 30 OF. SYSTEM —SPECIFIC C403.4.3 3.1 Mechanical Hydronic heat pump systems connected to a common water loop meet heat rejection and heat addition requirements. SYSTEM —SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have means to balance and have pressure test connections. SYSTEM —SPECIFIC C403.4.2 Mechanical VAV fan motors —7.5 hp to be driven by variable speed drive, have a vane -axial fan with variable pitch blades, or have controls to limit fan motor demand. SYSTEM —SPECIFIC C403 4 2.1 Mechanical VAV fans have static pressure sensors positioned so setpoint —1/3 total design pressure. SYSTEM —SPECIFIC C403.4 2 2 Mechanical Reset static pressure setpoint for DDC controlled VAV boxes reporting to central controller based on the zones requiring the most pressure. SYSTEM —SPECIFIC C403.4.5.4 Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM —SPECIFIC C403.4.3.4 Mechanical Hydronic systems greater than 300,000 Btu/h designed for variable fluid flow. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/ 1 /2017 Page 9 of 22 SYSTEM —SPECIFIC C403.4.3.4 SYSTEM —SPECIFIC C403 4.4 Plan Review Plan Review Air Leakage Air Leakage Air Leakage Air Leakage Air Leakage Fenestration Fenestration Insulation Insulation Insulation Insulation Insulation Insulation Insulation Insulation Insulation Insulation C406 C402.3 2.2 Mechanical Temperature reset by representative building loads in pumping systems for chiller and boiler systems >300,000 Btu/h. Mechanical Fan systems with motors —7.5 hp associated 1:1 El with heat rejection equipment to have capability to operate at 2/3 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. Project Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Envelope Skylights in office, storage, automotive service, manufacturing, non -refrigerated warehouse, retail store, and distribution/sorting area have a measured haze value > 90 percent unless designed to exclude direct sunlight. C402.4.1,C402.4.2 Envelope C402.4.3,C402.4.4 Envelope C402.4.1.1 Envelope C402.4.6 Envelope C402.4.8 Envelope C303.1.3 Envelope C303.1.3 Envelope C303.2 Envelope C303.2 Envelope C403.2.7,C408 2.8,( Envelope C402 4.2.1 Envelope C303.2 C402.2.1 C303.2 C303.2 C303.1 C303.2.1 Envelope Envelope Envelope Envelope Envelope Envelope The building envelope contains a continuous air barrier that is sealed in an approved manner and either constructed or tested in an approved manner Air barrier penetrations are sealed in an approved manner. Factory -built fenestration and doors are labeled as meeting air leakage requirements. All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor -permeable wrapping material to minimize air leakage. Weatherseals installed on all loading dock cargo doors. Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing , Fenestration products rated in accordance with NFRC. Fenestration products are certified as to performance labels or certificates provided. Below -grade wall insulation installed per manufacturer's instructions. Slab edge insulation installed per manufacturer's instructions. Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities Roof R-value. For some ceiling systems, 11 verification may need to occur during Framing Inspection. Roof insulation installed per manufacturer's instructions. Blown or poured loose -fill insulation is installed only where the roof slope is < 3 in 12. Skylight curbs are insulated to the level of roofs with insulation above deck or R-5. Above -grade wall insulation installed per manufacturer's instructions. Floor insulation installed per manufacturer's instructions. Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/ I /2017 Page 10 of 22 Insulation C402.2.1 Envelope Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Controls C405.2.4 Exterior Lighting Automatic lighting controls for exterior lighting installed. Controls C405.2.2.1 Interior Lighting Automatic controls to shut off all building lighting El El installed in all buildings. Controls C405.2.1.1 Interior Lighting Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Controls C405.2.1.2 Interior Lighting Lighting controls installed to uniformly reduce the lighting load by at least 50%. Controls C405.2.2.3 Interior Lighting Daylight zones provided with individual controls that control the lights independent of general area lighting Controls C405.2.3 Interior Lighting Sleeping units have at least one master switch at the main entry door that controls wired luminaires and switched receptacles. Controls C405.2.2.2 Interior Lighting Occupancy sensors installed in required spaces. Controls C405.2.2 3 Interior Lighting Primary sidelighted areas are equipped with 0 required lighting controls. Controls C405 2.2.3 Interior Lighting Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Controls C405.2.3 Interior Lighting Separate lighting control devices for specific uses installed per approved lighting plans. Controls C405.3 Interior Lighting Fluorescent luminaires within odd numbered lamp configurations that are with 10 feet center to center (if recess mounted) or are within 1 foot edge to edge (if pendant or surface mounted) shall be tandem wired Wattage C405.5.2 Interior Lighting Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. HVAC C403.2.4.5 Mechanical Freeze protection and snow/ice melting system sensors for future connection to controls. HVAC C403.2.3 Mechanical HVAC equipment efficiency verified. Air Leakage C402 4.5.1 Envelope Stair and elevator shaft vents have motorized dampers that automatically close. Air Leakage C402.4.5.2 Envelope Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. HVAC C403.2.8.1 Mechanical Piping Insulation exposed to weather is protected from damage (due to sun, moisture, wind, etc.) HVAC C403.2.7 Mechanical HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC C403.2.8 Mechanical Thermally ineffective panel surfaces of sensible 11 heating panels have insulation — R-3.5. HVAC C403 2 7 Mechanical Ducts and plenums sealed based on static pressure and location. HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means for air balancing. HVAC C403.2.11 Mechanical Unenclosed spaces that are heated use only radiant heat. HVAC C403.2.4.1 Mechanical Heating and cooling to each zone is controlled by a thermostat control. HVAC C403 2.4.2 Mechanical Thermostatic controls have a 5 'F deadband. 0 HVAC C403 2 4 2 Mechanical Temperature controls have setpoint overlap restrictions. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/ l/2017 Page 1 l of 22 HVAC C403.2.4.3 Mechanical Automatic Controls: Setback to 55'F (heat) and 85'F (cool); 7-day clock, 2-hour occupant override, 10-hour backup SYSTEM -SPECIFIC C404.3 Mechanical Temperature controls installed on service water 1:1 El heating systems (110 OF for dwelling units and lavatories in public restrooms and 90 OF for other occupancies.) SYSTEM -SPECIFIC C404.4 Mechanical Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. SYSTEM -SPECIFIC C404.2 Mechanical Heat traps installed on non -circulating storage 0 water tanks. SYSTEM -SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. 0 labeled for replacement only as per Footnote b to Table C403.2.3(3). SYSTEM -SPECIFIC C403.4.2 Mechanical VAV fan — 7.5 hp are driven by mechanical or electrical variable speed drive, or driven by vane -axial with variable speed blades, or operate with motor demand <=30% design kW at 50% design flow - calculations required SYSTEM -SPECIFIC C403.2.8 Mechanical HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. SYSTEM -SPECIFIC C403.2.7.1 3 Mechanical Ductwork operating >3 in. water column requires air leakage testing. SYSTEM -SPECIFIC C403.4.3.5 Mechanical Reduce flow in pumping systems >10 hp to multiple chillers or boilers when others are shut down. SYSTEM -SPECIFIC C403.4.3.3.3 Mechanical Two -position automatic valve interlocked to shut off water flow when hydronic heat pump with pumping system >10 hp is off. SYSTEM -SPECIFIC C403.4.6 Mechanical Condenser heat recovery system that can heat water to 85 OF or provide 60% of peak heat rejection is installed for preheating of service hot water in 24/7 facility, water cooled systems reject 6 MMBtu, SHW load >=1 MMBtu. SYSTEM -SPECIFIC C403.4.7 Mechanical Hot gas bypass limited to: 240 kBtu/h - 50% 240 kBtu/h - 25% SYSTEM -SPECIFIC C403.2.4.2 Mechanical Heating and cooling to each zone is controlled by a thermostat control Minimum one humidity control device per installed humidification/dehumidification system SYSTEM -SPECIFIC C403.2.4.3.3 Mechanical Systems include optimum start controls. SYSTEM -SPECIFIC C403.2.4.1.1 Mechanical Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. SYSTEM -SPECIFIC C404.3 Mechanical Public lavatory faucet water temperature <=110'F SYSTEM -SPECIFIC C404.5 Mechanical All piping in circulating system insulated SYSTEM -SPECIFIC C404 5 Mechanical First 8 ft of outlet piping is insulated SYSTEM -SPECIFIC C404.5 Mechanical All heat traced or externally heated piping insulated SYSTEM -SPECIFIC C404.6 Mechanical Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. SYSTEM -SPECIFIC C404.7 1 Mechanical Pool heaters are equipped with on/off switch and El no continuously burning pilot light SYSTEM -SPECIFIC C404.7.3 Mechanical Vapor retardant pool covers are provided for heated pools and permanently installed spas. SYSTEM -SPECIFIC C404.7.2 Mechanical Time switches are installed on all pool heaters and pumps. Testing C408 2 3.2 Mechanical HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/l/2017 Page 12of22 Mandatory Additional C406 Project Insulation C402.2.8 Project Efficient HVAC performance, efficient lighting system, or on -site supply of renewable energy consistent with what is shown the approved plans. Bottom surface of floor structures incorporating radiant heating insulated to > R-3.5. CpTolbeLcliecked'by Inspectorat Project Completion and Prior to Issuance of Ceftificate of Occupancy Post Construction C408.3 Exterior Lighting Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Post Construction C408.2.5.1 Interior Lighting Furnished as -built drawings for electric power systems within 30 days of system acceptance. Post Construction C303.3,C408.2 5 2 Interior Lighting Furnished O&M instructions for systems and equipment to the building owner or designated representative. Post Construction C408.3 Interior Lighting Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Post Construction C408 2 5.1 Mechanical Furnished HVAC as -built drawings submitted 0 within 90 days of system acceptance. Post Construction C303.3,C408.2.5.2 Mechanical Furnished O&M manuals for HVAC systems 0 within 90 days of system acceptance. Post Construction C408.2.5.3 Mechanical An air and/or hydronic system balancing report is provided for HVAC systems Post Construction C408.2.1 Mechanical Commissioning plan developed by registered design professional or approved agency. Post Construction C408.2.4 Mechanical Preliminary commissioning report completed and 0 certified by registered design professional or approved agency. Post Construction C408.2.5.4 Mechanical Final commissioning report due to building owner within 90 days of receipt of certificate of occupancy. Post Construction C408.2.3.1 Mechanical HVAC equipment has been tested to ensure proper operation. Post Construction C408.2.3.3 Mechanical Economizers have been tested to ensure proper operation EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/ 1 /2017 Page 13 of 22 Input Data Report Proiect Information Project Name: Youth Building Project Title: Central Baptist Church Youth Building Address: State: Florida Zip: 0 Owner: Building Type: Office Building Classification: Renovation to existing building No.of Stories: I GrossArea (SF): 4,201 Bldg. Rotation: None Zones No Acronym Description Type Area Multi Total Area sr[ Sn 1 Meeting Zone I CONDITIONED 1760.6 1 1760.6 Rooms 2 Multi -Purpose Zone 2 CONDITIONED 1452.4 1 1452.4 3 Multi -Purpose Zone 3 CONDITIONED 987.8 1 987.8 Spaces No Acronym Description Type Depth Width Height Mult Total Total IN ft[ ftl Area Vol[cfl sfl In Zone: Meeting Rooms 1 Meeting Room Meeting Rooms Conference/meeting (Multiple 41.96 41.96 10.00 1 1760.6 17606.4 Functions) In Zone: Multi -Purpose l Multi -Purpose Multi -Purpose Conference/meeting (Multiple 38.11 38.11 10.00 l 1452.4 14523.7 Functions) In Zone: Multi -Purpose I Multi -Purpose Multi-Purpose/Meeting Conference/meeting (Multiple - 31.43 31.43 10.00 1 987.8 9878.4 ' Functions) EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 14 of 22 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W1 Ctrl pts In Zone: Meeting Rooms In Space: Meeting Rooms t LED General Lighting In Zone: Multi -Purpose In Space: Multi -Purpose l LED General Lighting 2 LED General Lighting In Zone: Multi -Purpose In Space: Multi -Purpose 1 LED General Lighting 2 LED General Lighting 22 49 1078 ManualOn/Off 1 2 23 46 ManualOn/Off l 3 128 384 ManualOn/Off I 4 49 196 ManualOn/Off 1 3 128 384 ManualOn/Off 1 EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 15 of 22 Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H (Effec) Multi Area Orient Cond- Heat Dens. R-Value IN [ft[ plier [sf[ ation uctance Capacity [Ib/cf[ [h.sf.F/Btu[ Btu/h.sf.Fl [Btu/sf.F[ In Zone: Meeting Rooms I North Wall Metal 36.60 14.00 1 512.4 North 0.0920 1.072 19.38 10.9 siding/2x4@24"+R I l Batt/5/8"Gyp 2 West Wall Metal 48.25 14.00 1 675.5 West 0.0920 1.072 19.38 10.9 siding/2x4@24"+R I I Batd5/8"GYP 3 South Wall Metal 36.50 14.00 1 511.0 South 0.0920 1.072 19.38 10.9 siding/2x4@24"+R 1 I Batt/5/8"GYp In Zone: Multi -Purpose I North Wall Metal 59.66 14.00 1 835.2 North 0.0920 1.072 19.38 10.9 siding/2x4@24"+R t I Batd5/8"Gyp 2 East Wall Metal 24.33 14.00 1 340.6 East 0.0920 1.072 19.38 10.9 siding/2x4@24"+R1 l Batt/5/8"Gyp In Zone: Multi -Purpose 1 South Wall Metal 24.00 14.00 1 336.0 South 0.0920 1.072 19.38 10.9 siding/2x4@24"+R I I Batd5/8"GYp 2 East Wall Metal 11.42 14.00 1 159.9 East 0.0920 1_072 19.38 10.9 siding/2x4@24"+R l I Batt/5/8"GYp Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area Btu/hr sf F1 IN IN plier Isn In Zone: In Wall: EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/1/2017 Page 16 of 22 Doors No Description Type Shade? Width H (Effec) Multi Area Cond. Dens. Ht Cap. R IN IN plier [sf] [Btu/h.sf.Fl [Ib/cfl [Btu/sf. [h.sf.F/ F1 Btul In Zone: Meeting Rooms In Wall: South Wall 1 Door Solid core flush 2.25) In Zone: Multi -Purpose In Wall: East Wall l Door Solid core flush 2.25) No 3.00 7.00 2 21.0 0.3504 0.00 0.00 2.85 No 3.00 7.00 1 21.0 0.3504 0.00 0.00 2.85 Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier [sq [degi [Btu/h.Sf. F[ [Btu/sE F[ [Ib/cq [h.sf.F/Btu In Zone: Meeting Rooms I Roof Mtl Bldg Roof/R-19 41.96 41.96 1 1760.6 0.00 0.0492 1.34 9.49 20.3 Batt In Zone: Multi -Purpose l Roof Mtl Bldg Roof/R-19 38.11 38.11 l 1452.4 0.00 0.0492 1.34 9.49 20.3 Batt In Zone: Multi -Purpose l Roof Mtl Bldg Roof[R-19 31.43 31.43 l 987.8 0.00 0.0492 1.34 9.49 20.3 Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multi- Area Total Area Btu/hr sf F[ IN IN plier Isq [Sfl In Zone: In Roof: EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/ 1 /2017 Page 17 of 22 Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value fti [ftj plier [sfi lBtu/h.sf.F [Btu/sf. F1 [Ib/cf[ [h.sf.F/Btu In Zone: Meeting Rooms Floor 1 ft. soil, concrete 41.96 41.96 1 floor, carpet and rubber pad In Zone: Multi -Purpose I Floor 1 ft. soil, concrete 38.11 38.11 1 floor, carpet and rubber pad In Zone: Multi -Purpose I Floor l ft. soil, concrete 31.43 31.43 1 floor, carpet and rubber pad 1760.6 0.2681 34.00 113.33 3.73 1452.4 0.2681 34.00 113.33 3.73 I 987.8 0.2681 34.00 113.33 3.73 EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/l/2017 Page 18 of22 Systems AHU-1 System 1 Constant Volume Air Cooled No. Of Units Split System < 65000 Btu/hr 1 Component Category Capacity Efficiency IPLV 1 Cooling System 48000.00 18.00 11.60 2 Heating System 17065.00 1.00 3 Air Handling System -Supply 1600.00 0.80 4 Air Handling System - Return 1600.00 0.80 AHU-2 System 2 Constant Volume Air Cooled No. Of Units Split System < 65000 Btu/hr 1 Component Category Capacity Efficiency IPLV 1 Cooling System 48000.00 14.00 11.60 2 Heating System 17065.00 1.00 3 Air Handling System -Supply 1600.00 0.80 4 Air Handling System - Return 1600.00 0.80 AHU-3 System 3 Constant Volume Air Cooled No. Of Units Split System < 65000 Btu/hr 1 Component Category Capacity Efficiency IPLV l Cooling System 36000.00 14.00 11.60 2 Heating System 17065.00 1.00 3 Air Handling System -Supply 1200.00 0.80 4 Air Handling System - Return 1200.00 0.80 Plant Equipment Category Size Inst.NcEff. IPLV EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/ 1/2017 Page 19 of 22 Water Heaters W-Heater Description Capacity Cap.Unit I/P Rt. Efficiency Loss 7 EA -Lighting Description Category No. of Watts per Area/Len/No Control Wattage Lumin- Lumin- [sVft/Noj Type [W[ aires aire Piping No Type Operating Insulation Nomonal pipe Insulation Is Temp Conductivity Diameter Thickness Runout. 171 [ Btu-in/h.sf.Fl [inj [inj El Fenestration Used Name Class Type No. of - Glass SHGC VLT Panes Conductance Btu/h.sf.F[ EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/I/2017 Page 20 of 22 Materials Used Mat No Acronym Description Only RValue Thick Cond- Density Sp. Heat R-Value [h.sf.F/Btul IN uctivity [ib/cq [Btu/Ib.FI Used l Btu/h. ft. F 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 BOARD, l /21N 178 Matl178 CARPET W/RUBBER PAD Yes 1.2300 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 4 Matl4 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 271 Mat1271 2x4@24" oc + RI I Batt No 10.4179 0.2917 0.0280 7.11 0.2000 279 Matl279 Solid core flush (2.25") Yes 2.8537 94 Mat194 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/ 1 /2017 Page 21 of 22 J ` Constructs Used Simple Massless Conductance Heat Cap Density RValue No Name Construct Construct [Btu/h.sf.Fl [Btu/sEFl [Ib/cfl [h.sf.F/Btul 1019 Metal No No 0.09 1.07 19.38 10.9 siding/2x4@24"+R l 1 Batt/5/8"Gyp Layer Material Material Thickness Framing No. ft] Factor 1 4 Steel siding 0.0050 0.000 2 271 2x4@24" oc + R11 Batt 0.2917 0.000 3 187 GYP OR PLAS BOARD, 1/21N 0.0417 0.000 Simple Massless Conductance Heat Cap Density RValue No Name Construct Construct Btu/h.sf.Fl [Btu/sf.FI Ib/cfl h.sf.F/Btu] 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 Layer Material Material Thickness Framing No. IN Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000 2 23 6 in. Insulation 0.5000 0.000 Simple Massless Conductance Heat Cap Density RValue No Name Construct Construct Btu/h.sf.Fl [Btu/sf.Fl Ib/cfl h.sf.F/Btu] 1057 l ft. soil, concrete floor, carpet and No No 0.27 34.00 113.33 3.7 rubber pad Layer Material Material Thickness Framing No. IN Factor 1 265 Soil, l ft 1.0000 0.000 2 48 6 in. Heavyweight concrete 0.5000 0.000 3 178 CARPET W/RUBBER PAD 0.000 Simple Massless Conductance Heat Cap Density RValue No Name Construct Construct Btu/h.sLFl [Btu/sf.Fl lb/cfl h.sf.F/Btul 1058 Solid core flush (2.25) No Yes 0.35 2.9 Layer Material Material Thickness Framing No. - IN Factor 1 279 Solid core flush (2.25") 0.000 EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Florida Building Code, Fifth Edition (2014) - Energy Conservation IECC 2012 - Total Building Performance Compliance Option 3/l/2017 Page 22 of 22 INSPECTION SEQUENCE BP# % 7 /IA ADDRESS: BUILDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Slab / Mono Slab Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame 710 Insulation Rough Firewall Screw Pattern 3 o Drywall / Sheetrock Lath Inspection Building Ceiling Air Barrier 4(0 Insulation Roof (Com'l) Building Ceiling Grid Sri Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence Final Commercial —New Final Commercial"— Addition / Alteration Final Commercial — Change of Use Final Building (Other) ' l; is •f..':rt:t a:}./ni::.i.[:c,'i:'i}`"'':7.t' i y•.:•t'; '=y S:.llSri ti:y i.`•C: EIECTRICAI:FPERIVIIT' ? fJi R "•:t Y- L:.Y.4i .' v h ' Min Max Inspection Description Electric Underground Footer / Slab Steel Bond 0 Electric Ceiling Rough 0 Electric Wall Rough Electric Rough Pre -Power Final Temporary Pole ADO Electric Final i _ l? a..,e.['' L tti 3C•w'..5'.'_F,L •' y SML•1Lne• a Min Max Inspection Description Roof Storm Drain Rough O Plumbing Underground Plumbing 2"d Rough Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough Plumbing Final 1VIECHANI,•CALi'PERNi1T'}nc i.. ^Y:: Yet, :i.'.- s.'.i..t.. . Tn •'yr, 1(y:•—+s•f','y.r aiV.^.!F•=''.\zM :•I`yI`y y Y'.i i:.:.y u;. i•°'"y..5:': .! •.S:.o,..:3'.iT='•-n ! x.•;:;i7•`'u Min Max Inspection Description 0 Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space 2-0 Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Check Welds Mechanical Grease Duct Wrap 1600 Mechanical Final REVISED: June 2014 r Revision 2 Response to Comments Permit # i - ( I g Project Address: 3l t I l City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Submittal Date 5- • I Z 0 Y u Ul- 1 7 Contact: MAA46eIc(6 Vc7 li e_P LLS Ph: 115D Fax: 4 DJ - Email: rn8,--e c. Corte N MAY 122017 Trades encompassed in revision: General description of revision: BY, Building Plumbing Electrical -(OAv Si on Mechanical Life Safety Waste Water Department Utilities Waste Water Planning Engineering Fire Prevention ROUTING INFORMATION Approvals Deen, Joy From: Deen, Joy Sent: Tuesday, May 16, 2017 8:59 AM To: Deen, Joy Subject: RE: Central Baptist Youth Center The plans submitted on may 12t' contain the same KVA rating ( 54.50 ) as the previous plans with a change in amperage of 193 from original 151. Plan have to be revised for 23,000 kva._ ` From: Deen, Joy Sent: Monday, May 15, 2017 10:15 AM To:'Matthew Fenton' <matthew@clear-engr.com> Subject: RE: Central Baptist Youth Center Two sets of revised Sheet E0.2 will have to be submitted for revised panel legend From: Matthew Fenton [mailto:matthew@clear-engr.com] Sent: Thursday, May 11, 2017 2:57 PM To: Deen, Joy <Joy.Deen@Sanfordfl.gov> Cc: Darius Adams <darius@clear-engr.com>; Maverick Von Herbulis (maverick@mckeeec.com) maverick@mckeeec.com> Subject: RE: Central Baptist Youth Center Joy, Please see below and the attached sheet for the panel calc. This is a high leg system so the load is not evenly balanced across three phases. In this case, we determine which phase is more heavily loaded (A phase = 23.2 kva), we then convert kva to VA (23,200va), and then divide this number by 120 volts (Phase to neutral voltage) 23.2 kva * 1000 = 23,200VA 23,200/120 volts = 193 amps Please call me if you still have questions. Thanks, Ce-CU-EAR ENGINEEItING Matthew Fenton, LEED AP Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-ener.com From: Matthew Fenton Sent: Wednesday, May 10, 2017 10:34 AM To: 'been, Joy' <Joy.Deen @Sanfordfl.gov> Cc: Darius Adams <Darius@clear-engr.com> Subject: RE: Central Baptist Youth Center Since this is a high leg system, were summing each phase individually. We then calculate the phase with the highest load - A PHASE (Worst Case) 23.2 kva * 1000 = 23,200VA 23,200/120 volts = 193 amps ICE CLEA R ENOINEEAING Matthew Fenton, LEED AP Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-engr.com From: Deen, Joy [mailto:Joy.Deen@Sanfordfl.eov] Sent: Wednesday, May 10, 2017 10:27 AM To: Matthew Fenton <matthew@clear-ener.com> Subject: RE: Central Baptist Youth Center Show me your actual calculations From: Matthew Fenton [mailto:matthew@clear-engr.com] Sent: Wednesday, May 10, 2017 9:14 AM To: Deen, Joy <Joy.Deen@Sanfordfl.gov> Cc: Darius Adams <darius@clear-engr.com> Subject: RE: Central Baptist Youth Center Joy, Our revised panel schedule sheet is attached. Panel DP calculated amps have been adjusted based on this 120/240v, high leg delta system. Please give me a call if you have any questions. Thank You, ICE eL'*AR ENGINEERING Matthew Fenton, LEED AP Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-ener.com 2 Deen, Joy From: Deen, Joy Sent: Tuesday, May 16, 2017 8:59 AM To: Deen, Joy Subject: RE: Central Baptist Youth Center The plans submitted on may 12t' contain the same KVA rating ( 54.50 ) as the previous plans with a change in amperage of 193 from original 151. Plan have to be revised for 23,000 kva. From: Deen, Joy Sent: Monday, May 15, 2017 10:15 AM To:'Matthew Fenton' <matthew@clear-engr.com> Subject: RE: Central Baptist Youth Center Two sets of revised Sheet E0.2 will have to be submitted for revised panel legend From: Matthew Fenton [mailto:matthew@clear-engr.com] Sent: Thursday, May 11, 2017 2:57 PM To: Deen, Joy <Joy.Deen@Sanfordfl.gov> Cc: Darius Adams <darius@clear-engr.com>; Maverick Von Herbulis (maverick@mckeegc.com) maverick@mckeegc.com> Subject: RE: Central Baptist Youth Center Joy, Please see below and the attached sheet for the panel calc. This is a high leg system so the load is not evenly balanced across three phases. In this case, we determine which phase is more heavily loaded (A phase = 23.2 kva), we then convert kva to VA (23,200va), and then divide this number by 120 volts (Phase to neutral voltage) 23.2 kva * 1000 = 23,200VA 23,200/120 volts = 193 amps Please call me if you still have questions. Thanks, Ce C L E A R, ENGIN1EERINO Matthew Fenton, LEED AP Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-engr.com From: Matthew Fenton Sent: Wednesday, May 10, 2017 10:34 AM To:'Deen, Joy' <Joy.Deen@Sanfordfl.gov> Cc: Darius Adams <Darius@clear-engr.com> Subject: RE: Central Baptist Youth Center Since this is a high leg system, were summing each phase individually. We then calculate the phase with the highest load - A PHASE (Worst Case) 23.2 kva * 1000 = 23,200VA 23,200/120 volts = 193 amps Ce'(! LEAk ENGINEERING Matthew Fenton, LEED AP Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-engr.com From: Deen, Joy [mailto:Joy.Deen@Sanfordfl.gov] Sent: Wednesday, May 10, 2017 10:27 AM To: Matthew Fenton <matthew@clear-engr.com> Subject: RE: Central Baptist Youth Center Show me your actual calculations From: Matthew Fenton [mailto:matthew@clear-engr.com] Sent: Wednesday, May 10, 2017 9:14 AM To: Deen, Joy <Joy.Deen@Sanfordfl.Rov> Cc: Darius Adams <darius@clear-ensr.com> Subject: RE: Central Baptist Youth Center Joy, Our revised panel schedule sheet is attached. Panel DP calculated amps have been adjusted based on this 120/240v, high leg delta system. Please give me a call if you have any questions. Thank You, ICE CLEAZ ENGINEERING Matthew Fenton, LEED AP Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-engr.com PLEASE NOTE: Florida has a very broad public records law. Any written communication to or from City officials regarding City business is a public record available to the public and media upon request. Your e-mail communications may be subject to public disclosures. Deen, Joy From: Matthew Fenton <matthew@clear-engr.com> Sent: Thursday, May 11, 2017 2:57 PM To: Deen, Joy cc:, Darius Adams; Maverick Von Herbulis (maverick@mckeegc.com) Subject: RE: Central Baptist Youth Center Attachments: E0.2.pdf Joy, Please see below and the attached sheet for the panel calc. This is a high leg system so the load is not evenly balanced across three phases. In this case, we determine which phase is more heavily loaded (A phase = 23.2 kva), we then convert kva to VA (23,200va), and then divide this number by 120 volts (Phase to neutral voltage) 23.2 kva * 1000 = 23,200VA 23,200/120 volts = 193 amps Please call me if you still have questions. Thanks, Cie C Lf A R' ENGINEERING Matthew Fenton, LEED AP Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-engr.com From: Matthew Fenton Sent: Wednesday, May 10, 2017 10:34 AM To:'Deen, Joy' <1oy.Deen@Sanfordfl.gov> Cc: Darius Adams <Darius@clear-engr.com> Subject: RE: Central Baptist Youth Center P S — v 7 ter 7J 3 aoXA3 Since this is a high leg system, were summing each phase individually. We then calculate the phase with the highest load - A PHASE (Worst Case) 23. 2 kva * 1000 = 23,200VA 23, 200/120 volts = 193 amps Cie C L E A R' ENGINEERING Matthew Fenton, LEED AP 1 Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-engr.com From: Deen, Joy [mailto:Joy.Deen@Sanfordfl.gov] Sent: Wednesday, May 10, 2017 10:27 AM To: Matthew Fenton <matthew@clear-engr.com> — - — -- Subject: RE: Central Baptist Youth Center Show me your actual calculations From: Matthew Fenton [mailto:matthew@clear-engr.com] Sent: Wednesday, May 10, 2017 9:14 AM To: Deen, Joy <Joy.Deen@Sanfordfl.gov> Cc: Darius Adams <darius@clear-engr.com> Subject: RE: Central Baptist Youth Center Joy, Our revised panel schedule sheet is attached. Panel DP calculated amps have been adjusted based on this 120/240v, high leg delta system. Please give me a call if you have any questions. Thank You, Ce. C LE R ENGINEERING Matthew Fenton, LEED AP Project Manager 13651 Crystal River Drive Orlando, FI 32828 Tel: 407 277 3431 Cell: 407 414 8367 matthew@clear-engr.com PLEASE NOTE: Florida has a very broad public records law. Any written communication to or from City officials regarding City business is a public record available to the public and media upon request. Your e-mail communications may be subject to public disclosures. z