Loading...
HomeMy WebLinkAbout1511 Elliott St 17-1768 (a)Remove Existing Existing Window / 3.5 x 3.5 Window / ----------------------------------- I --------- Block-------- ---------------------------- 110V F1 110VF1 I I III �1. Remove Existing Flooring 2. Remove Existing Ceiling Drywall Storage Room 3. Remove Existing Wall Drywall F_ 14.Remove Existing Electrical 8 I 5. Remove Existing `frim 2 "v Light �6. Relocate Existing A/C Duct and Vent Existing A/C Vent to remain I 11 Relocate as Needed Existing 3.0 x 6.8 Exist. Pre -cast -I 1 Kitchen/Dining Room Closed Doorw�aJy Lintel to remain �- ��I---- Block ----_---_= ice° iRemove Existing lock Fill Wall I I I I lOV Remove Existing A/C Ducting from 1. Remove Existing Flooring ��' Garage Space �q 12. Remove Existing Ceiling I 220V Drywall Remove Existing �3. Remove Existing Wall Drywall L Cone. Ste 4. Remove Existing Electrical 5. Remove Existing Trim . 6. Remove Existing A/C duct and Vent I •� I I \Vl l I / \ 1 11 Living Room i 1 I � II �1 I �.� Light I 1 I 110V _I I l i / Family Room i ---- r - - - 1 iRemove Existing / Existing I- - - _I I R� Cone. Ste I Window I� 3 0 Covered Porch 110V l l O V 7�-I I I� -------I------I __--- T Block] -1 ----------------! ----- Existing L - - - - - - - -------1 4.8 x 4.8 Window 1 I I I I I I W 11 Remove Existing Ph /. Cover and Framing O J �• o lv rra 'Remove Existing Window Itit VI �' N (JQ 0 c Ct. tWay I - Remove Existing Window and Blk. I Driveway Filled Wall to recrea original garage door DEMOLITION PLAN opening 1/211= 11 .. .. ,. .. ... .. ... + .., ... ..' : F 4LLDINIENSIONSAN I)DE'FAILS BEFORE CONS I RUCTION COMMENCES 1.AUllIOLGfl G12L:\rG\iLN, IIAS Iih.N.N l�1hEN'IUL\SUItL ACCUI4\C\(1ECIIESC.C(1NS1'RUCIION ll14\V1L\GS,JIIS G1hES DO OCCUIL[C IS IIII. ILLSI U\SIBILIlY OF 1HE C0\llLlC101i'lO FIELD VERT Y. 2: 1'I IS'IHL RESPONSIBILICY OF TIIE COXIRAC1OR'IO REV] ENV"FIIE'CRl1SS Ei\GINE;ERLNG PACke1GE,AS COIIYLEI'ED OV U'l'RENE, AGALNS'C'IU E' I'LOOR PlJ_SAND ELE%Ar IOMAND RE PORE AINY DISCREPANCIES TO THE, DE:SIGNLR ANn'CRUSS CU,NlI!ANY BEFORE CO�NS'CItUC'EION COMMENCES. 3:DUE'IUSIIItINK\GL:-NDEXI',-NS1U\OFP.,tNCOP[ES,1VRIFTENDIIIENSIO\ST-,tKEPRF"CENDENCEON'Eit SC:\LLNG. 'GENEERS CERIIFICAI'EOF"HE CONSIRUC'l'ION DIL\NV'LNGS AREV'L BLEFOR6\lON'IITS OR UN TIL GOVERNING AGENCY CODI,CI1A4N(:ES'CAI(L: EFFECT" IF'CODE CIL\N(:ES'IAKE EFEC'rLUIS 'THE RESPUNSIBII.CCYOF'CIIEOWNER OR CUNCRACTORTO ENSURETILYCALL CONS TRUC TPON DRANV'I.NGSARL BROUGII'C UP'CO'CIIE LA'IES'r CODE SPECIFICATIONS BEFORE SUBJB C'ILNG FOR PERMIT. IF PLANS ARE SUTER I ED FOR PER.)IIT, IILFORE CI1.\NGLS IL\VE HLFN NLWE DUE;'I'O CODE UPDATES, I'1' IS (HE RESPONSIBILITY OFT HE OWNER OR CON'IRAC'IOR to COlIPEN'SA'IF THE DESIGNER AND ENGINEER FOR UPDA'IES,PRIN'IING AND CI: RE IFICA'l'IONS. DEMO NOTES: JUN 1 i '&Z1 Existing / / 3.5 x 3.5 Window ---------------=----------------------------- / Block ! ---------I - !---------------------I-- C I I I III I I III Kitchen/Dining Room Storage Room 2 8 �� SCOPE OF WORK: To Reconfigure Existing Family Room back to a garage as was originally constructed. 1. Remove Existing Flooring. 2. Remove Existing Ceiling. 3. Remove Existing Electrical. 4. Remove Existing Steps. 5. Remove Existing Drywall on Walls. 6. Block Closed Existing Openings as Shown. 7. Remove Existing A/C Duct and Vent from Garage. 8. Re -direct Existing A/C in Storage Room. 9. No work beyond the Building Shell to be done. 10. Relocate Existing Water Heater from Kitchen to Laundry Room. 11. Replace Existing Alumn. Soffit and Facia. 12. Replace Existing Interior doors. 13. Replace all Existing Flooring with Like or Contractor Approved. 14. Replace Existing Kitchen Cabinets in Like Configuration. 15. Replace Existing Bathroom Vanity and Toilet. 16. Replace Existing HVAC system. 17. Replace all Existing Outlets and Switches. 18. Install New Combo Carbon monoxide and Smoke detectors. In each Bedroom, Kitchen, Hall and Living Room. 19. Repair Existing drywall as needed. 20. Re -Paint all interior and Exterior walls and trim. 1, Temporary Shoring should be in place where needed, before any construction takes place. 2. Both Design and installation of Temporary Shoring is the responsibility of the Contractor. 3. All Demolishing should be performed with Extreme Caution as to not disturb Existing Structure which is to remain. 4. Any Damage to Existing structure Should be brought to the attention of the E.O.R. in writing. NOTES: 1. RENOVATLON TO EXISTING STRUCTURE ONLY 2. All Work and Materials to match Existing Conditions. 3. All Wood products that is against existing concrete to be pressure treated. 4. Any new Electrical is to meet NEC 2011 requirements. 5. All Rebar to be Grade40 w/ 25" Laps Min. 6. All new concrete to be 2500 psi. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS; DURING DEMO, IF IT IS DETERN1 NED ACTUAL CONDITIONS VARY FROM WIIAT IS SHOWN ON TIIESE PLANS, CONTRACTOR IS'r0 NOTIFY E.O.R. FOR FURTHER REVIEW. v Llght I�� Ili I II Existing -i 3.0 x 6.8 \(Closed Doorway �L_� � ----Blocic----------I � I 1 I Existing A/C Duct and Vents IlUV ISI 1� I I I °I I � I I I I 220V I--I-- I I I I I I I I I 1 A W I_ \I z` Light 110V j I 77-- 7Q I I Family Room ISI III III Living Room i �I 30---1-------_�-- / Existing L + _ i Window °� I 3 0� Covered Porch -I F_ `✓'� - 44 -t 'I 1 l O V I � - 1 1 $ fl) _------I----, -I-- i--------=-----------=-�--1-----!------ 1 I Existin 1 L-------------- 4.8 x4.8, and Bloc Walkway --------------------------- I EXISTING CONDITIONS 1/2" = F l i Ire re, x si i i f he iir , r aid ' I - ' i r icl i ltisure h� 'ill 'i C tint ,and or State ft s Isblt o t Cotaclo StbLol onto ldl( (,t o Ree uireulents/Codes/S )CCifications arc utet and liis/Her Res misibllit to check with the above noted I I I ) A reucies if t I uestiotis should arise. b u„h Greg Wilson, Design Management PH: 407-252-9037 Dra"'°: GWw 466, Weathersfield Avenue Altamonte Springs, Florida 32714 rhwengr @ hotlnail.com Date: 05.09-2017 Seale: NOTED Windt) � Filled Dri v 3 RECORD REVIEWED FOR CODE ling P�ANL-QRR u+>>zl7tRQ_ J1VI.:;MJ A PERMIT ISSUED SHALI_ BE CON; LICENSE TO PROCEED'F11TH THE (A AUTHORITY TO VIOLATE, CANCEL TRUED TO SE A )RK AND NOT AS ACrER OR SET ASIDE ANY OF THE PROVISIONS Of CODES, NOR SHALL ISSUANCE OF F THETECHNICAL PERMIT PREVENT THE BUILDING OFFICIAL FRO1VI THEREAFTER REQUIRING A CORRECTION OF EF TORS IN PIANS, CONSTRUCTION OR VIOLATION: OF THIS CODE All Dimensions shown are to be Field Verified before Construction Commences Note: This Structure has been designed to n]eel or exceed the wind D,S. "Vinder° Chehal load requirements of the 2014 Florida Building Code Residential, Fifth �7 - 1 7 6 �` Edition, SCetioR R301 Design Criteria and including ASCE 7-10. L1seIlsed Professional Engineer I I. Wind Speed = 139 mph Ultimate Wind Speed (vult) and los n]ph (vasd) BUILD/y 2 P.E. 79118 _. Risk Carr of _ o> - 6_4 Dou las Avenue - Suite 1418 Construction :Type -Single Family Residence (V) a 3 Wind Exposure = Catgor , "C" SANFOR,. 1 0 > Altamonte Springs, Fla. 32714 J 4. Internal Pressure Coefficient ror enclosed building is .l S and Height and 407 227-7368 and Exposuro adjushucut Couflicicnl is 1:40 CONTRACTOR: CBI PROJECTADDRESS: Title or Page: CBI 15 l L Elliot Street EXISTING CONDITIONS AND DEMO PLAN Corinthian Builders, Inc. Sanford, Fla. signature: 4;/ /7 Sheet 1 of 3 /L -------------------------Block – – – – NEW IIOV -I GFIC nlis diagamaiie plan is intended to show lionino and eeme,dun" outlets only. I US. Chuhal, YE will bear no responsibility for ifs accuracy. It is the aleetricul eon'aulors responvibility to verify the requirements and locations of all electrical services m required Eleotrluul contractor to sabmil clactdcal plop and pull permits as required. I Storage Doom 1\ I I I F_ -1 I Light F_ II ice_' i Iii 1 I i til I I 1 r l I I j 1 1 ALL EXISTING ELECTRICAL [S TO BE FIELD i I ` $ $� NEW Switches I I 0 VERFIED BEFORE CONSTRUCTION COMMENCES. t- -I - - - - - - - - - - - - - - - -1 I FIELD VERIFY EXISTING ELECI'[ICAL AND 3 Block ----------------- REPLACE OR RELOCATE AS NEEDED, I ALL ELECTRICAL IS `CO MEET NEC 2011 STANDARDS. I �. I�j I I 1 Existing home Hazard Detection Upgrades or Additions: I I I I I I 1. Provide Smoke Detectors in all Sleeping Rooms and within the I I I Immediate Vicinity of Sleeping Rooms & Carbon monoxide Detectors I i within 10 ft. of all Sleeping Rooms if not Existing. i 1 l I I 2. All smoke detectors are to have battery backup and be hardwired and interconnected so that in an event one is activated (if not existing) unless I I said interconnecting and hardwiring would require removal of interior wall 7,I I or ceiling finishes which expose the sh-uctnre. I 1 I 3. All smoke detectors are to be located no less than 36 inches from ceiling fans. I NEW GARAGE j ALL BEDROOM SOCKETS ARE TO BE ARC FAULT TNTERUPT TYPE NEW IIOV GFIC ALL WET AREA SOCKE'T'S ARE TO BE GFIC � I I L g i ht NEW IIOV GFIC 77 I / I I ISI / ----------------- 0 ----------- --0 F---I--------J-- /I` - -- - - - -- — - - - - I / Existing I– -I NEW Switch iWindow i > ` Covered Porch //�Z I _ — I I F-1 L--------- — ----------L— — I -1---- I I I I L----------------� I I I I I Walkway I I I I Driveway - - - - - - - - - - - - - - - - - - - - - - - - - - I I I PROPOSED ELECTRICAL PLAN t/211 = 1' 'INGS\lIS'I'AKES UO OCCUR. I IS THE RESPONSIBILITY OF THE CON "IRAC 'IOR'10 FIELD VERIF'YALL DIMENSIONSAND DETAILS BEFORE CONS'IRUC'1'ION COUNIENCES '..11 THESE )V."RCC"1(IN DR<i\I I: IT I FLIE R SPONS' CARIE HAS III!E CONI N'l'O IR10 REVIENV EMU LNG INEE l PLETCD BY O'r111SRE AC:AINS'I'l 11E F'LOOK PLAN <4VO F:1,1?V.YrlONS<4Cn I(EPOR'LANY IFISCILEl'e1:NCIN:S TO TUE DESIGNER <ANU'l'RUSS COMPANY BEFORE CONS 'rR1iC'IION CUNLVIE LACES. 2: fr IS'C[IC IFES P(FNSItlILI l'}' OF LIFE CON I(EVIE\V'l'llE'fKUSS ENGINEERING PACICA(:I?�:\S COaI , 3: DUE 10 SHRINKAGE AND EXI'ANSIO-Y OF PAN COPIES,WRII'LEN DIMENSIONS TAKE PRECENDENCE OVER SCALING. ' \ O' VIABLE FOR (i M(FNTIIS OR UNTIL GOVERNING AGENCY COIF: CHANGES TAf(E EFFECT. IF CODE' C1I:4\(:ES'1'AKE F:N'ECT if 1S'I'HN: I1GSI'O\S1tlIL1'C l' OF'F[IE OWNER (Fri CON 'L lL1C'IOH"CO ENSURE'1 k4\f.\LL 4: ENGINEERS IUNVIN SAR01' 1E ECOUGR IUC I (ONP101 BE LAX\CN:I CONS'IKU(:'IION UIL1W'L\G4.\I(E BHOUGII'I' UI"Ill'Fllli LACES'l COIL SI'I?CI FI(:AI'IONS HI?PURE SL'Bhll'I"l'L\G F012 I'El011'1'. IF I'CLANS ARI; SU BAII'I'TEU FOR l'F:ItAI I'1; BEFORE Cl1AN<:I,S II1V 1:RFE\ YI.ADE DIF, i0 CODE UPU<1l'N:S, If LSTHE HESPONS[UfLI'fY OF WE OWNER OR CON 'l'KAC'[OR to COMPFNSAI'' IH'. DESICNERAND ENGINEER FOR UPDAIESYRIN IINGAND CEK'IIFICAI[ONS. Laundry RoomAt EXISLI[r NEW BLOCK FILL I I Kitchen/Dining Room g 220v Socket See Detail "D" ---------I-1------------------� Block ��i�/ I _ Existing 3'-611 NEW Block Fill I. P.T. 1" x 2" Furring Strips 2. R8 Insulation F_I_I 3. Painted Drywall in Storage Room. I Existing �� 4. Painted Drywall Ceiling i 1 8 -5 �� w/ R19 Insulation. r_� +(r- _ 5. Flooring as Specified by Contractor. I Til Existing Block Fill 1 i Removed. Finish for I new door and trim. NEW SolidAdd Auto Closure z 0----------------I L3 I B lock IN —1 ----------------- A. Door between Garage and living area Io 4" Step i to be a minimum 20 minute solid core I �q door and self closing 1 B. Interior part of wall, between garage 1 Existing 8„ and living space, to have 1/2” finished I I o 1 drywall minimum. i Existing 10'-6" WATER PROOFING NOTE NOTE: IT 15 THE RESPONSIBILITY OF TFIE BUILDER TO GOOf?DINATE THE INSTALL/ -\TION OF ALL � VIATERPROOFING METHODS NEGE55ARY TO PRO\/IDE A WATER 'FIGHT BUILDING ENVELOPE. REFER TO MFR. INSTALLATION IZFGONIMENUATIOH FOR ALL SELFGTED I,-l,&j=RPROOFING t-WFERIAL5, FLASHING, SEALER5 AND AD -MIX GOMPONENTS. w Existing 6'-2" U +or - O New Blk. Fill p Q W 2 +or - 1. Painted Block in Garage. 2. Painted Drywall Ceiling w/ R19 Insulation. 3. Concrete Flooring Living Room ISI of ------------------------ I i 30 -- T-------- T_- � I - 1 /'Apply 2't x 6'"P.T. w/-�/2" dia. x 8" 1 anchor bolts a) 2' O.C.'s4i 2' washer. Covered Porch 6" frons op and bottom Max�� r_< I i 9' Garage Door V 1 1 71 F-1 --- -------- -----------L--� Exist. Block Fill Removed F 33 - .4 sf L----------------1 SEE SFtEE' 3 of Fo, I Block Fill Details. I I 11 Walkway Existing 9'-4" + or - 1 NEW Garage Door Opening I L --------------------------I Driveway I I I I I I I I I I I � I I w U U Existing 2'-7" NEW B ock Fill �Q I 1 � I iz� I I I w U �Q Existing 7-6" O - NEW Block Fill ctQ v� PROPOSED FLOOR PLAN CONTRAC'T'OR TO FIELD VERIFY ALL EXISTING 1/2" — 1' CONDITIONS; DURING DEMO, IF IT IS DETERMINED ACTUAL CONDITIONS VARY FROM WHAT IS SHOWN ON THESE PLANS, CONTRACTOR IS TO NOTIFY E.O.R. FOR FURTHER REVIEW. it IS the rfbsibi lily othe Culaa cor ad Sub-Cvlrctos to Isre t t (tll City, Col1 Il(( I 01' stilte F ' I h h' ove iiote(l ' III to check w t (lie db I lis/I 6cs rouslb t r m ld I las/ �dions a e el a " 1 �clhc( IAe(uirculents/Cods/S I I I Agencies if questions should arise. Greg Wilson, Design Management PH: 407-252-9037 Dralvn: cww Date: 05-09-2017 466 Weathersiield Avenue rhwengr C[ hounail.com Seale: NOTED Altamonte Springs, Florida 32714 All Dimensions shown are to be \ Field Verified before Construction Commences Note: this Structure has been designed to meet or exceed the wind D.S. "Vinder" Chehal load requirements of the 2014 Florida Building Code Residential, Fitch Edition, Section R30 t Design Criteria and including ASCE 7-10. Lisensed Professional Engineer 1. Wind Speed = 139 mpll Ultimate Wind Speed (vulo and 108 mph (vasd) P.E. 791 t8 2. Risk Category 2 2 D til sAvenue Suite 1418 624 oto a = Constnlcliou type Single Family Residence (V) 3. Wind Exposure=Category ^C" Altamonte Springs, Fla. 32714 4. lnlenlal Pressure Coefficient for enclosed building is .18 and Height and 407 227.7368 and Exposure ndjushncul CoclficiauL is 1:10 CONTRACTOR:PROJECTADDRESS: Title of Page: CBI 1511 Elliot Street PROPOSED FLOOR and Corinthian Builders, Inc. Sanford, Fla. ELEC'CRLCAL PLAN sig"(111Ce' / Street 2 of 3 MNOM OR DOORFRAME � ELA5TOMERI6 HALANT CLOSED GFL L BACKER ROU --/ PRUYIOE • ..:. 5TUC1,0 STOP STfrGGU rINIJII BAr-, EK' ROD PET Ai ` 15A6rER ROD INrSTALLED AT ALL L '%NDON5, DOORS, G CONTROL JOINT5 5/8" Stucco (j� Exterior Side of Wall -------- — ----- 3' V ----3'-6" + 45 Rebar pins with 6" embedment L 3'-6" epoxied each end. Grout Fill Cell + or - 5/8" Stucco Exterior Side of Wall #5 Rebar pins with 6" embedment epoxied each end. Grout Fill Cell 5/8" Stucco @ Exterior Side of Wall DETAIL IID" n.t.s. +g r - L-2'-8"—� +or - DETAIL 'IC" 111s. Add P.T. 1" x 2" Furring strips g 16" O.C.'s w/ R5 Insulation between and 1/2" :Drywall over ((� Interior side of Wall w/ 5d nails at 7" O.C.'s #5 Rebar pins with 6" embedment epoxied each end. Grout Fill Cell ainted Block g Garage Side of Wall Painted Block @ Garage Side of Wall 95 Rebar pins with 6" embedment epoxied each end. Grout Fill Cell #5 Rebar pins with 6" embedment epoxied each end (2'-6" O.C.'s I L 8" x I� I 51-21 o�ncreete-B ocic 95 Rebar with 6" Embedment epoxied each end in Grout filled cell 'fi'•:' , #5 Rebar pins with 6" embedment #5 Rebar with 6" Embedment epoxied each end 2'-6" O.C.'s I epoxied each end in Grout filled cell 7-6" + or DETAIL "B" 111s. L•ALCIOCC1L CKEAI'CrRE (IAS (SEEN'C:1Rh;N TU ENSURE ACCUILCCY OF'IIlESE GUNS CItCC'110:V DL 11WINGS,\IIS'fAIiES DO OCCUR. I'FIS'fllERESPONSInILI'I'YOF'CIIECON'1'ILtCTOR 10 FILL D VERIFYALL (MIENS IONS AND DUrA1LS BEFORE CONS I RUC LION COMIN LACES f 2: CC IS TDE RESPO:NSIRILI'I'Y OF'FIIE CON'rltACfOlt"l'O REV IE X IIIE'fKUSS ENGIN H:N;RINC l'ACIGAG If,AS COSIPLE'CED RY O'l lIN:RE,ACAINS'I"IIIE I'LOOK VL:IN AND LLEVA'CIONS AND REFORF ANY DISCREPANCIES'10'f11E DESK NEIL AN D'CRUS5 CO\il!A:V Y BEFORECONS'CRUCTION COMMENCES. 3:DUE'I'O SIIRINIiAGEAND EXI'.1.VSION OFFA:V COPIES,WRI'I'1EN DL.\1ENSIONS'I'AKEPItECENDENCEOVEIt SC,1LL\G. INGS.UtE VIABLE FOR 6 VIONTIIS Olt UNTIL GOVERNING AGENCY:N CODE: CIfACES'I:ARE EFFECT'. tFCODE CILINCES'GllCE EtFC'C rC IS'CIIE RESPONSIIIILCI'YOF'ME OWNERORCONTRACTOR IO ENSURE'fFL1T ALL J: ENGINEERS CI!ItCIFICAI E OF fHE CUNS'CRUC'CION llILAIV" CONS'CItUC'CION DILkVN'INGSARE DROUGII'f UP'IU'ILIE LATEST CODE SPECIt[CAI IONS REFOIM SUBMITTING FOR PERMIT. n'PLANSARE SURVICC'LED FOR MOIL[, BEFORE CHANGES HAVE REE:N MADE DUE 'to CODE UPDA'CES, I'C IS'I'IIE RESPOINSIRILITY Of"I'lllC OWNEIL Olt CUN'C1LAC'COR 'LO COMPENSAM IItl: DUSIGNERAND ENCLVEER FOR UPBA'CES,PRIN LINC AND CERTtFICAI IONS. Add P.'1'. I" x 2" Furring strips a 16" O.C.'s w/ R5 Insulation between and 1/2" Drywall over Interior side of Wall w/ 5d nails at 7" O.C.' #5 Rebar with 6" Embedment epoxied each end in Grout filled cell #5 Rebar pins with 6" embedment Epoxied each end a 3'4" O.C.'s CONTRACTOR TO FIELD VERIFY ALL EXIS'T'ING CONDITIONS; DURING DEMO, IF rf lS DETERMINED ACTUAL CONDI'T'IONS VARY FROM WHAT IS SHOWN ON THESE PLANS, CONTRACTOR ISTO NO'T'IFY E.O.R. FOR FURTHER REVIEW. bout Y and or state I ' I'e h1t III Cl � n rlclor and Sub Contractors to f Iso f ( tti, ti it is the res lonsiblht at the Col ( I i h he above Noted ' r Rc � Ionsibilil � to chccl� n t t r' t e and His/He s •'n 9l,llt ' Icciticaho s ( 1 l � irenlcnts/Codi,/S I u{u I { Agencies il•questions shou{d arise. P.T. 2" x 6" Wood Jamb Anchored _ to Block w/ 1/2" x 8" anchor bolts c� 24" O.C.'s Painted Blk. Track�'�` -- ;a- r Match Exist 45 Vert. Rebar in Ext. Finish Poured Cell JAM Nt' GARAGE DOOR —Metal Garage Door I" x 2" Trim DETAIL "A" n. t. s. Garage Side of Wall 5 Rebar pins with 6" embedment poxied each end @ 3'-4" O.C.'s 811 Ir - 45 Rebar with 6" epoxied each enc 7\) Embedment in Grout tilled cell 9 All Dimensions shown are to be Field Verified before Construction Note: This Slructurc has been designed to utect or exceed tire wind D.S. "Vinder" ChAat load reyuircnrents ofthe 2011 Florida Building Code Residential, Mill Edition, section 8301 Dcsign Criteria raid includi"g ASCE 7-10. Lisensed Professional Engineer 1. wind speed — 139 mph Ultimate Mad speed (vrat) and 108 mph (vasd) P.E. 791 18 2. Risk Cracgory2 - g 624 Douglas Avenue - Suite 1418 Con Construction Type =Single Family Residence (V) 3. Wind Exposure = Category "C" Altamonte Springs, Fla, 32714 4. hilc"ml Pressure Coefficient for enclosed building is .18 and Hcight and (407) 227-7368 and ENposum adjustment Coefficient is 1.40 PH: 407-252-9037 Drawn: cww Data 05 -OJ -2017 CONTRACTOR: PROJECTADDRESS: Title of Page: Greg Wilson, Design Management . F31 1511 Elliot Street DETAILS ��g�/7 466 WrtlhcrsricldAverale Signature: Sheet 3 Of 3 Altanlonlc Springs, Florida 32714 rhwengr @ hotlnail.com Scale: NOTED Corinthian Builders, Inc. Sanford, Fla. Remove Existing Driveway and CMU Below. L --------------------------I for New 6' S.G.D. DEMOLITION PLAN 1/2" = I' Window Cut ope " I: e1LCIl00011 GNE.I'C CARE fi.\S HEF.N'GIKEN TO INSURE ACCUIGICY ON"CHESN: CONS 1'RUC'l'lON URAW'INGS,AIIS'I'AIiES DO OCCUR. IC IS'l'll N: ltE51'ON5IUll.l'UY OFTIIE CONTRACCOR iO FII;I.D VEItIF'YAI.I. UCIIENSI(EVS ANU llE'I'.111.5 BEFORE CONS'[RUCTION COi,LN1ENCES 2: IT [S'C[IE RESFON'S]IHLI'TYOF'CIIE CON'CRAC'[Olt UO REVLEW'I HE' IRUSS ENGINEP;RLNG PACli,IGE,U CO�NlPLEIED BY O'l'HURE,?.GAINS'I THE FLOOR PLe1N,'ND ELEVglONSANU REPORCA.VYDISCREPANCIES TO TIIE "N:SIGNElt AND'LRUSS CONIMNY BEFORE CONSTRUCTION COALNIENCES. 3: DUE to SHRINKAGE AAD EXPANSION OF PA:V COPIES,WRHAEN DIMENSIONSFAKE PRECENDENCE OVER SCALING. 1 ITY OF THE OAI'NHit OIL CO:V'L ItAC[OR'IO ENSU RE; TILVT ALL ')VFI GL'\'' OUE III,V'L:ESI'AIiG GI FLC I. IF CODE CHANGES LAKE hFEC'I l'l IS [FIE RESPONSIBILITY A:ENG'LVEERS CER'CIFICAIE OL"IIIL:CONSIILUC LION U&Iw'LVGSARU V411{LI; GOR riAR)NIIIS OR UNTIL (.( .IVINGA :OIC C . CONS"I'RUC TION DILIWIVGSARE DROUGHT UP 10 UUE LAUESI CODE SPECIFICATIONS BII'ORE SUBNHAT'I NG FOR PERMUL IF PLANS AHE SUBNILT' I'ED FOR VEILVII'I', BEFORE CTIA\GUS HAVE DLEN ALIDE DUE to CODE UPDATES, it IS THE RESPONSIBILITY OI" fill,OWNER OR CONTILAC[OR '1'O COMPENSATE "rl1E DESIG:VERAND ENGINEERFOR UPI)MES,PRIN'[LNG AN.0 CER[HFICATIONS. Greg Wilson, Design Management P1I: 407-252-9037 466 WeatherslieldAvenue Altamonte Springs, Florida 32714 rliwengr@hotmail.com DEMO NOTES: SCOPE OF WORK: Existing / 3.5 x 3.5 Window / ----------------------------------- I --------- / Block --------J L----------------- ----1---------1 - I N rrl / I I I10V I�. 4,, I I I I I vl (Jci Kitchen/Dining Room �- Storage Room III o� 8 2 �v Light - I F_ - - ' I I Existing -i o 3.0x6.8 I Closed Doorway -----------------I I Repair and Recondition ��1 /SII_ _ _ _Block 4F_ - - ----------I Existing Family Room and Storage Room o I/�I and New Insulation I A/CD 1 V 1. Temporary Shoring should be in place where needed, before any construction takes place. 2. Both Design and installation of Temporary Shoring is the responsibility of the Contractor. 3. All Demolishing should be performed with Extreme Caution as to not disturb Existing Structure which is to remain. 4. Any Damage to Existing structure should be brought to the attention of the E.O.R. in writing. NOTES: 1. RENOVATION -TO EXISTING STRUCTURE ONLY 2. All Work and Materials to match Existing Conditions. 3. All Wood products that is against existing concrete to be pressure treated. 4. Any new Electrical is to meet NEC 2011 requirements. 5. All Rebar to be Grade40 w/ 25" Laps Min. 6. All new concrete to be 2500 psi. REVIEWED FUR CODE COMPLIANCE P EXAMINER DATE SANFORD BUILDING DIVISION A PERMIT ISSUED $HALL BE CONSTRUED TO BE A LICENSEAUTHORITY to VIOLATE, CANCEL ALTER OR K AND SS ET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REOUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE CONTRACTORTO FIELD VERIFY ALL EXISTING CONDITIONS; DURING DEMO, IF ITIS DETERMINED ACTUAL CONDITIONS VARY FROM WHAT IS SHOWN ON THESE PLANS, CONTRACTOR IS TO NOTIFY E.O.R. FOR FURTHER REVIEW. I I I Remove Existing Window I I Field Verified before Construction 1 11OV and Block Close. See Detail "C" ��� Existing D.S. Winder" Chehal / Lisensed Professional Engineer 3.5 x 3.5 Window !------------------- / ---------------- ------------ Block -------- ----1--------1 - ----------------- / 7 - 407 2_7 7363 220V I I i I 110V I I I I I I I I III 1. Remove Existing Flooring 12. Remove Existing Ceiling O Nup I X I W I Drywall � \\ Storage Room 1 1 3. �4. RemoveExisting Y Wall Drywall Remove Existing Electrical Light "� I 5. Remove Existing Trim 8 2 "� - Light -� 6. Relocate Existing A/C Duct l / Family Room and Vent -' - rn• Living Room Existing A/C Vent to remain I r ------ -- - C// 0 � - - - �3 Relocate as Needed ' i i--- Room_ %1L -------II --!------- 1 / Existing L i Kitchen/Dining _________________________I Window i Block I�-------------------------I I ISI I I I I I I I 1 IOV Relocate Existing /C Ducting and vent 1. Remove Existing Flooring i2. Remove Existing Ceiling 220V Drywall 3. Remove Existing Wall Drywall �4. Remove Existing Electrical �I I 5. Remove Existin Trim emove I � I I I� bO Remove Existing / \ I. w I Conc. StepI// L -I Living Room I I I I F_ 7- ��� Light I 11 OV _I Family Room I 0--- --------r--- i / I Existing i Remove Existing Window - - _I l I i Conc. Ste and Door I 3 0 1'// i Covered Porch I 110 V 70- IL II --------------L-� I - �----- ------------I------ - - - - Block -------- Existing L-----------------� I 4.8 x 4.8 Window I I Walkway I Remove Existing Driveway and CMU Below. L --------------------------I for New 6' S.G.D. DEMOLITION PLAN 1/2" = I' Window Cut ope " I: e1LCIl00011 GNE.I'C CARE fi.\S HEF.N'GIKEN TO INSURE ACCUIGICY ON"CHESN: CONS 1'RUC'l'lON URAW'INGS,AIIS'I'AIiES DO OCCUR. IC IS'l'll N: ltE51'ON5IUll.l'UY OFTIIE CONTRACCOR iO FII;I.D VEItIF'YAI.I. UCIIENSI(EVS ANU llE'I'.111.5 BEFORE CONS'[RUCTION COi,LN1ENCES 2: IT [S'C[IE RESFON'S]IHLI'TYOF'CIIE CON'CRAC'[Olt UO REVLEW'I HE' IRUSS ENGINEP;RLNG PACli,IGE,U CO�NlPLEIED BY O'l'HURE,?.GAINS'I THE FLOOR PLe1N,'ND ELEVglONSANU REPORCA.VYDISCREPANCIES TO TIIE "N:SIGNElt AND'LRUSS CONIMNY BEFORE CONSTRUCTION COALNIENCES. 3: DUE to SHRINKAGE AAD EXPANSION OF PA:V COPIES,WRHAEN DIMENSIONSFAKE PRECENDENCE OVER SCALING. 1 ITY OF THE OAI'NHit OIL CO:V'L ItAC[OR'IO ENSU RE; TILVT ALL ')VFI GL'\'' OUE III,V'L:ESI'AIiG GI FLC I. IF CODE CHANGES LAKE hFEC'I l'l IS [FIE RESPONSIBILITY A:ENG'LVEERS CER'CIFICAIE OL"IIIL:CONSIILUC LION U&Iw'LVGSARU V411{LI; GOR riAR)NIIIS OR UNTIL (.( .IVINGA :OIC C . CONS"I'RUC TION DILIWIVGSARE DROUGHT UP 10 UUE LAUESI CODE SPECIFICATIONS BII'ORE SUBNHAT'I NG FOR PERMUL IF PLANS AHE SUBNILT' I'ED FOR VEILVII'I', BEFORE CTIA\GUS HAVE DLEN ALIDE DUE to CODE UPDATES, it IS THE RESPONSIBILITY OI" fill,OWNER OR CONTILAC[OR '1'O COMPENSATE "rl1E DESIG:VERAND ENGINEERFOR UPI)MES,PRIN'[LNG AN.0 CER[HFICATIONS. Greg Wilson, Design Management P1I: 407-252-9037 466 WeatherslieldAvenue Altamonte Springs, Florida 32714 rliwengr@hotmail.com DEMO NOTES: SCOPE OF WORK: Existing / 3.5 x 3.5 Window / ----------------------------------- I --------- / Block --------J L----------------- ----1---------1 - I N rrl / I I I10V I�. 4,, I I I I I vl (Jci Kitchen/Dining Room �- Storage Room III o� 8 2 �v Light - I F_ - - ' I I Existing -i o 3.0x6.8 I Closed Doorway -----------------I I Repair and Recondition ��1 /SII_ _ _ _Block 4F_ - - ----------I Existing Family Room and Storage Room o I/�I and New Insulation I A/CD 1 V 1. Temporary Shoring should be in place where needed, before any construction takes place. 2. Both Design and installation of Temporary Shoring is the responsibility of the Contractor. 3. All Demolishing should be performed with Extreme Caution as to not disturb Existing Structure which is to remain. 4. Any Damage to Existing structure should be brought to the attention of the E.O.R. in writing. NOTES: 1. RENOVATION -TO EXISTING STRUCTURE ONLY 2. All Work and Materials to match Existing Conditions. 3. All Wood products that is against existing concrete to be pressure treated. 4. Any new Electrical is to meet NEC 2011 requirements. 5. All Rebar to be Grade40 w/ 25" Laps Min. 6. All new concrete to be 2500 psi. REVIEWED FUR CODE COMPLIANCE P EXAMINER DATE SANFORD BUILDING DIVISION A PERMIT ISSUED $HALL BE CONSTRUED TO BE A LICENSEAUTHORITY to VIOLATE, CANCEL ALTER OR K AND SS ET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REOUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE CONTRACTORTO FIELD VERIFY ALL EXISTING CONDITIONS; DURING DEMO, IF ITIS DETERMINED ACTUAL CONDITIONS VARY FROM WHAT IS SHOWN ON THESE PLANS, CONTRACTOR IS TO NOTIFY E.O.R. FOR FURTHER REVIEW. I I I LXistmg U%,t anc ents I I Field Verified before Construction 1 11OV Commences Note: 'chis Structure has been designed to Daet or exceed the wind D.S. Winder" Chehal load requirerneuts of the 2014 Florida Building Code Residential, Firllr Edition, section 8301 Design Criteria and including ASCE 7-10. Lisensed Professional Engineer U P.E. 79118 2. Risk Category 2 Conslnmliou Type =Single Family Residence (V) v las Avenue - Suite 1418 6_2i Douglas a 3. wind Exposmo - Category "C" Altamonte Springs, Fla. 32714 c icicn to enclosed Wilding is .18 and Height and �'uro Ca [t t r b d. hilcnml Prean 6 0 7 - 407 2_7 7363 220V I I i I _ I I I I I I I I I I bn Family Room O Nup I X I W I I/ \ � I I cfq I I Light 110V I � I l / Family Room rn• Living Room r ------ -- - C// 0 � - - - �3 I ' i i--- _ -------II --!------- 1 / Existing L i Window i I C4 I RECORD COPY 0 1 bf) Covered Porch 3// ,//11 �'/ 110V j //,// I w�110V�I-i #17-17 I II �I I I ----- ----- r Block I 6�LLDrNO L---- --------------L- ------------------ ------ - - I Existing T SANFORD L -----------------i 4.8x4.8 Window °FpARTCn�� and Block Filled Opening I Walkway Exist. Pre -Cast Lintel � r I I, L -------------------------I It is the responsibility of the Contractor and Sub -Contractors to Insure that all City, County and or State P Y Rec uirements/CodeslSpeciicati ns are met and His/Her Responsibility tocheck with the above noted f questions o Agencies i sti ns should arise, Dr -a: GWW Dam: 05-09-2017 Scale: NOTED Driveway 08 EXISTING CONDITIONS All Dimensions shown are to be Field Verified before Construction 1/2" = 1' Commences Note: 'chis Structure has been designed to Daet or exceed the wind D.S. Winder" Chehal load requirerneuts of the 2014 Florida Building Code Residential, Firllr Edition, section 8301 Design Criteria and including ASCE 7-10. Lisensed Professional Engineer 1. wind Speed = 139 n)ph Ultimate wind speed (Vnit) and 108 mph (vasd) P.E. 79118 2. Risk Category 2 Conslnmliou Type =Single Family Residence (V) v las Avenue - Suite 1418 6_2i Douglas a 3. wind Exposmo - Category "C" Altamonte Springs, Fla. 32714 c icicn to enclosed Wilding is .18 and Height and �'uro Ca [t t r b d. hilcnml Prean 6 0 7 - 407 2_7 7363 and Exposure adjustment Coefficient is 1.40 CON'TRAC'TOR:PROJECTADDRESS: Title of Page: CB1 1511 Elliot Street EXISTING CONDITIONS Corinthian Builders, Inc. Sanford, Fla. AND DEMO PLAN signature: 9�z7//7 Sheet 1 of 3 / / /!--------------------------Block----------------- ---------- --------- --- ----1---------J-- (P NEW IIOV ! —1 GFIC l l This diaycaualic plan is intended to sh— lighting and convcruenca outlets only. D.S. Chchal, PP. will beta no responsibility for it's accuracy. It is We electrical contractors responsibility to verify tiro—Iuirumcnts and locati— of all electrical services as requited. Electrical contractor to submit electrical plan and pull permits :s required Storage Room Light 1 Storage Room I I I I I I I ALL EXISTING ELECTRICAL IS TO BE FIELD VERFIED BEFORE CONSTRUC'T'ION COMMENCES. � L — Block I FIELD VERIFY EXISTING ELECTRICAL AND _ _ _ _ -------------- — ---- REPLACE OR RELOCATE AS NEEDED. ALL ELECTRICAL IS TO MEET NEC 2011 STANDARDS. NEW I lOV Existing home Hazard Detection Upgrades or Additions: I I I I I 1. Provide Smoke Detectors in all Sleeping Rooms and within the Q Ilmnediate Vicinity of Sleeping Rooms & Carbon monoxide Detectors 1 j within 10 ft. of all Sleeping Rooms if not Existing. j NEW l 1 OV I I I I 2. All smoke detectors are to have battery backup and be hardwired and I interconnected so that in an event one is activated (if not existing) unless L- —1 1 said interconnecting and hardwiring would require removal of interior wall or ceiling finishes which expose the structure. I 1 I I I 3. All smoke detectors are to be located no less than 36 inches from ceiling fans. I I I 11 ALL NEW SOCKETS ARE TO BE NEW I lOV I I ARC FAULT INTERUPT TYPE Family Room 1 ALL WET AREA SOCKETS ARE TO BE GFIC L _I I I Light I I I r— _.------ _.—.—• I I NEW Switch—i I I II ISI III I of I I Z� I ii I I I / ---1 iii ------------ I / 30 NEW IIOV 1 1 / I Existing I I Window I I J�NEW I IOV i1 I Covered Porch I j I ISI I F-1 F -I 1 I I I L-----------------1 I I I I I Walkway I I I 1 Driveway t ---------------------------I I I PROPOSED ELECTRICAL PLAN 1/2" = F 1: ALL'HOUCII GREAT CARE HAS BEEN L1 KEN '101ASUREACLURACY OFTHESE CONSIRUCTION DIG\W'LNGS,\IIS LOTS DO OCCUR. If IS THE RESPONSIHILL'1'YOF'1'IIE CON1'RACTORTO FIELD VERUI, YALL UL\ILVSIONS AND DETAILS BEFORE CONSTRUCTION COALVIENCES :: CC [S'1'HE RESI'ONSIIfILICI'UG'CI1E CUN'LItAC'CUK'l'O 2EV1EW"fllE'CRUSS ENG4\CERD\C I'A<:KACE,AS CO,IIPLETCD BY OIIfER E,AGALVS'1"IIlE FLOUR P1.:1N e\.\ll ELEV.\'CIONS.I:VU REl'Uli l':1NYUl5CREPANCIM;S TO TIIE DESI<:NER.4Vll'CRUSS CU,\ 1 P.ANYBEFORE CONSTRUC[ION COMMENCES. ' }: UUE TO SIIRNK.\GF..\:VD EXP:L\BION OF PA:V CUl'fES,WRCI"CEN llI11ENSIONS'C.U4E PRECN:NUENCEU1'N.R SCALING. "1 OIL ON" 1 AC'IOR'CO ENSURE TIL\I' ALL l: CNGNEC;RSCERCIFICAII;UF"I ME CUNS'IRUC'LION llIL\\VNGS.\I(N; VIABLE GOI26 �ION'1I1SUl1 UN'L[LCO\'EILVNGAGE:VCYCODE CII.1:\(:F:S'1:AKIi EF'N'ECG IF CODE ClI.4\GEST.\KE EFEC'f It IS'CHM: RESPONSIHII.I'Cl'OF'CfIEO\Vi\Li C It. CONSI'RUC'IION DRAWINGSARE. BIi(I UGII'CUP 10 1 H LALES 'C CODE SPEW ICAI'IONS BEFORE: SUB.NlI'I"TING FOR PERAIIL IF PLANS ARE SU B;•ll'r, ED FOIL PERAICI', BEFORE CIIANGBS IL\VE BEEN GLADE DUE'CO CODE UPDATES, CC IS'I'HE RESPONS1B11.1'CY OF FRE OWNER OR CON V%C'[OR 'CO COaIVENSA'1'1:'I'IIE DESIGNERAND ENCNEER FOR UPDAAES,rRIN'I INC ANI) CERLIFICA'l1ONS. Greg Wilson, Design Management PH: 407-252-9037 466 Weathersfield Avenue Altamonte Springs, Florida 32714 rhwengr (c_D, hotmail.coln / DETAIL "C" !---------------------- / --- Block -----------------1 I----- ;. / Storage Room l I I III I I III 1. New Flooring per contractor specs. WA'T'ER PROOFING NOTE NOTE: IT 15 THE RESPONSIBILITY OF THE BUILDEF' TO GOORDINATE THE IN5TALLATION OF ALL WATERPROOFING METI-I005 NEGE55ARY TO PRO\/IDE A WATER TIO -FIT BUILI)NO EN\/ELOI'E. .REFER'TO MFR. I1,15TAL.LAT16N REGOMMENDATION FOR. ALL 5ELEGTED 1^IATERPROOFING MA"FERIAL5, FLA5FnN6, . SEALER5 AND AD—NIIX GOF�IPONENTS. 2. New 1/2" Ceiling Drywall 3. New 1/2" Wall Drywall 4. New Painted Trim 6. Relocate Existing A/C Duct �I and Vent. lq yr 7. New R Insu ation in Ceiling. I 8. Walls and Ceiling to be Painted. I I I I I I I I I I1-------------- ----------- I Block ---------------- l of Denotes cells to have (1) #5 rebar w/ 6" Embedment and filled solid w/Concrete I I I I I I I I I I I I L —I I I Family Room I I I I 1. New Flooring per contractor specs. I 2. New 1/2" Ceiling Drywall 3. New 1/2" Wall Drywall 4. New Painted Trim I I 1 6. Relocate Existing A/C Duct and Vent and reuse existing. I g• I I 7. New R19 Insulation in Ceiling. I of 8. Walls and Ceiling to be painted. / I I I — — i _ _ _ _ — — i _ — — I 2" x 8" Framing typ. r—�-- I / Existing Window I G1 I Covered Porch w Q 6'-618" S.G 1 — 34.6 psf 1: 171 F-1 ----------- —-------L— I DETAIL "A" I L-----------------1 I I j Walkway I Driveway I I L---------------------- --1 I I L_ I I I I I I I I I I—I—� II III III III III III I I III II III II II II II II II II II II I I I ;place Existing Windows th Like Size and install Manuf. - 34.6 psf REVISION SANFORD CONTRACTOR TO FIELD VERIFY ALL EXISTING PROPOSED FLOOR PLAN All Dimensions shown are to be 'T' CONDITIONS; DURING DEMO, IF ITIS DETERMINED 1/2" = P Field Verified before Construction ACTUAL CONDITIONS VARY FROM WHAT IS Commences SHOWN ON THESE PLANS, CONTRACTOR IS TO NOTIFY E.O.R. FOR FUR'T'HER REVIEW. Note:'this SDUCUIIchas been designed wtncetorexceed the Wind D.S. " Vinder" Chehal load requirements of the 2014 Florida Building Code Residential, Finll Edition, Section R30 t Design Criteria alta including ASCE. 7-10. Llsetlsed Professional Engineer It is the of the Contractor and Sub -Contractors to Insure that all City, Count and or State Y 1. Wind Speed= 139 mplr Ultimate Wind speed (volt) and 1081np11(vasd) P.E. 79118 responsibility p y Y Regtlirementsl des S eciications are met and HislHer Responsibility to check with the above noted _. Risk Cateoory2 Conslructioti fYE c = single Family Residence V 3. Wind Ex Category �C� 6 24 Douglas AV cane Suite 14 1s Altamonte s tm8so Fla. 3271 if arise, usnrc— 'l.hilenl:d Pressure Cocllicieut for enclosed building is.l8 and Height and and Exposure adjushneut Coefficient is 1110 l407 227-7368Agencies questions should Drawl: GWW Date: 05-09-2017 CONTRACTOR:PROJECTADDRESS: CBI Title or Page: 1511 Elliot Street Scale: NOTED Corinthian Builders, Inc. PROPOSED FLOOR and Sanford, Fla. ' ELECTRICAL signature: /,1//;?//� Sheet 2 of 3 NZON OR DOOPFPAME P.T. 2" x 8" w/ 1/4" x 4" Tapcons to Exist. Cone. Simpson H5 ea. Vert. Exist. Lintel Above Interior: ' ELA5TOM�PIG - 'z Tt/ 1/2" Drywall w/ 5d nails I 5EALMT C! T' O.C.'s typ. j G1_05ED GELL . F R13 Insulation typ BA( iKER ROD 6 -8 5TV605TOP ----�� #5 Rebar with 6" embedment S_PJGGO FINI5H epoxied each end. Grout Fill Cell 5AGKER ROP OF -TAIL Exterior: 2 1-8 tt -- 7/16" OSB nailed w/ 8d ring shank 15A(KER POP INSTALILED AT ALL I C, 4" O.C.'s w/ House Wrap and + or - NINDON5, D0oR5, Y GONT901L JOINT5 15# Felt w/ Galv. Lath and 7/8" Simpson H5 Stucco over typ.. ea. Vert. Lath: A11 lath and. lath attachments shall be of 'corrosion -resistant materials. Expanded metal or woven wire lath shall be'attach'ed with 1112 -inch -long (38 rnm), 11 . gage nails having a 7/16 -inch (11.1 mut) head, or 7/8 -Inch - long (22.2 mm),16 gage staples, spaced at no more than 6. inches (132 ruin). Weep screeds: I t1 minimum U.019 -inch (U.� mm) (No 26 galvanized sheet ;age), currosiou-resistant weep screed or plastic weep screedU, with a minimum vertical attachment flange of 31/inches (89 ;nm.) shall be provided at or below the foundation plate line on exterior stud walls in . accordance with -"ASTM C 926. The weep screed shall be placed a minimum of 4 inches (11,12rum) above the earth or 2 inches (51 mm) above paved areas and shalt be of a type that will " allow trapped water to drain to the exterior of the building. The weather -resistant barrier shall lap the attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep screed. Water -resistive barriers: Water -resistive barriers shall be installed as required in Section 8703.2 and, where applied over wood -based sheathing 'shall include a nater -resistive vapor -permeable barrier with a perfurmance at least equivalent to two layers of Grade D paper. The individual layers shall b'e installed independently such as each layer provides separate continuous plane and any flashing (installed in accordance with Sectior. 8703.8) intended to drain to the water - resistive barrier is directly between the layers. Exceptiun: Where the water -resistive barrier that Ls applied over wood -based sheathing has a water resistance equal to or greater than that of 60 -minute Grade D paper and is separated from stucco by all intervening, substantially nonwater-absorbing layer or designed drainage space. fWoud Casing 3/4" Furring Strip 'h'ith i/2" Drynull 41.' ..� i -I ► .. f -i DE'T'AIL 1 Ll" P.T. 2" x 8" w/ 1/4" x 4"J 11A.S. Tapcons to Exist. Cone. -Door From To Block Per h!anul'. Specs . 2x P.I. Miith 1/4" Dia. x 3" Tapcons Staggered At 8" O.C. Per Elevation L�' Vertical Bur On Poured Cell OF Sllovn On Floor Plan) Jamb Afi Exterior aoore --..--Threshold -•--h1etvl Or &od Door —+ --Sill 3/4" Furring Strip IYitli 1/2" Drpioll �7lindon Sill Malarial -ifjndaw 1 a I--.- - -- - Concrete Sill it P.T. Ix i'findoa' Buck Anclia To hlasunry Per I/,lgr. Specs Fnish Per Elevation 1#5 Vertical Ber On Poured Cell (IF Shown On Floor Plan) Jamb At �Ui�do�r� 95 Rebar with 6" embedment epoxied each end. Grout Fill Cell Exist. Rooting—\ P.T. 2" x 8" w/ 12d nails 6" O.C.'s to Exist. Beam /4" x 4" Tapcons @ 8" O.C.'s typ.— , #5 Rebar with 6" embedment epoxied each end. Grout Fill Celt��� Interior: 1/2" Drywall w/ 5d nails cc 7" O.C.Is typ. R13 Insulation typ.T—� Exterior: 7/t6" OSB nailed w/ 8d ring shank g 4" O.C.'s w/ House Wrap and 15# Felt w/ Galy. Lath and 7/8" GENERAL LUMBER NOTES: All Lumber to be Southern Yellow Pine #2 with a Maximum Moisture content of 19%. Exterior Lumber to be Pressure Treated. Studs may be Spruce 92 Grade. Provide Vapor Barrier Between All Non -Pressure Treated Lumber and Concrete. All Anchor Strapping Hardware to be Galvanized when attached to Pressure Treated. Lumber. A 7/811 CEMENTITIOUS FINISH or Siding FELT/ PAPERBACKED LATH MATERIAL LAPPED MOISTURE BARRIER (HOUSE WRAP) WOOD SHEATHING (7/16" OSB) 7/D. MOISTURE BARRIER ('WALL TRANSITION) - DRIP EDGE CE,IENTITIOUS FINISH CONCRETE BLOCK OR SOLID CEMENT NOTE: . 1 -ALL EXTERIOR ACCESSORIES SHALL BE PVC MATERIAL CONFORMING TO ASTM STANDARDS 01734,'C926, C1063 AND D4216. 2 -CAULK ALL BUTT JOINTS, ENDS, ANGLES, AND INTERSECTIONS AT TIME OF INSTALLATION. CONTROL DEAD WITH DRIP EDGE N. f.5. "1'C(R'HAS HEENTAI(EN T(/ INSUREACCURACY OF iHESE.CONSTRUC'TIONDR.VIVLNGS,YIIS'I'AKES DO OCCUR. I'FIS'IIIERESPONSIBILIUYOFiHECONTILIC'IOR'I'U MUD VERIFYALLDIMENSIONS AND DF�PAILS BEFORE CONSTRUCTION COMMENCES 1. 1 CIS [IJERESPON E 2: I'l' lS'nlE I1ES1.ONSI HILICY OF TIIE CON 'IRAC'[OR [U ItEVICW'rHE'I'RUSS h;\GI:VEERL\C I'ACKIGE,LS COSIPLETED BY (/'1111:1iE,:\CALVS'C'111E FLUOR PL.UV AND ELGV.1l 1(1NS A.Vll I(I:YORI'e4V YD[SCi2EPANCIIiS'CU'LIlE UN:SIGNER ANll'I'R1;55 COJII'e1NYBEFORE C(/.VSTI(UCl'ION C(1\I\[ENCES. 3: DUE TO SHRINKAGE AND EXPANSION OF PAN COPIES,W RII"CEN D"ICNSIONS TAKE. PRECENDENCE OVER SCAULVG. TABLE FOR 6,110 RS OR UN TIL GOVEltNLNGAGENCYCODEC[LA,NCES'C"iE EFFECT.IF CODE CIL1NCES'1'AKEEIEC'I'ITISTHE RESPONSIBIL1'CYOFUIEOWNER OR CONTRAC'IOR'10 ENSU RE TILYCALI. A: 1:\CL\F.N.ItS CERTIFICA CE OC'CI[E CONSTKEGIION UItA\\'INCS ANL V CONS CRUC'1ION DRAY\ IN(:S A RL+ BROUGn'I UP 10'1 ILE LACES C CODE SPEC[ FICA'CIONS HEFORE SUB3R CC1NG FOR PERAUH. IF I'I.:1NS ARM: SUBill'ICIED FOR PERNITI', BEFORE CIL4NGCS IIAVE BEEN 3LADE DUE'CO CODE UPDAI ES, IF IS'tHE RESPONSIBILITY OF THE OWNER OR CON'CRAGCOR 'I'OCOMPENSAI'E'IIIE AiSIGN'ERAND ENGINEER FOR UPDATES,PIUN'I INLAND CERTIFICATIONS. Greg Wilson, Design Management P1-1: 407-252-9037 UraWrr: oww 466 WealherstieldAvenllo rhweugr @ hotmaiLcom Allamonlo Springs, Florida 327t4 Stucco over typ.. P.T. 2" x 8" w/ 1/4" Y 4" Tapcons to Exist. Cone. Exist. Cont. Span 2x8. Install New 2x8 and attach to Exist. 2x8 with 12d nails staggered at 8" O.C.'s each Simpson LSTA24 side, entire length. ea. Vert. Exist. 2x8 Roof Rafter #5 Rebar with 6" embedment epoxied each end. Grout Fill Cell DE'T'AIL "A" n. t. s. _�rN or - Use (1) HTSM16 tap con to existing block w/ 1/4" x 4" tap cons each end of (2) 2x12's Typ. #5 Rebar with 6" embedment epoxied each end. Grout Fill Cell 2" x 8" Framing For S.G.D. Install ist. Cont. Span Pre -Cast Lintel Above ------ ---- --- L. T New Windows r I'' —Varies #5 Rebar with 6" embedment epoxied each end. Grout Fill Cell DETAIL "B" n.t.S. 12" - #5 rebar pins epoxied 6" into existing CMU Exist. Cont. Span Pre -Cast Lintel Above ----- --------- --New 8" CMU Verify :•I .I 95 Rebar with 6" embedment t e oxied each end. Grout Fill Cell �► #5 Rebar with 6" embedment t. Verify p ::1 ; epoxied each end. Grout Fill Cell 1 CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS' DURING DEMO IF IT IS DETERMINED WATER PROOFING NOTE NOTE: IT 15 THE' RE5PON51BILIT`( OF THE BUILDER TO GOOi?DINATE THE INSTALLATION OF ALL VIATERPROOFING HETFIOD5 NEGE55ARY TO PRO\/IDE A HATER "FIGHT BUILE)06- EN\/ELOPE, REFER TO MFR. INSTALLATION , REGOMMENDATION FOR ALL 5ELEGTED WF)TERPROOFING I -I krERIALS, FLA5HING, DEALERS AND AD -MIX 60MPONENT5. ACTUAL CONDITIONS VARY FROM WFIAT IS SHOWN ON THESE PLANS, CONTRAC'T'OR Is TO NOTIFY E.O.R. FOR FURTHER REVIEW. It is the res onsibilit of the Contractor and Sub -Contractors to Insure that all City, County and or State p Y r I " I noted Kee uirementslCodes/S t,clfications are met and HislHer Responsibility to check with the about, 1 p 1 ld arise. in hal ( '' if nest o s s Agenues q Date: 05-09-2017 CONTRAC"I'UR: PROJECTADDRESS: ITitle of Page: CBI 1511 Elliot Street Seale: NOTED Corinthian Builders, Inc. Sanford, Fla. DETAIL 11C" 11A.S. Note: This Structure has been designed to meet or exceed the Wind load requirements or the 2014 Florida Building Code Residential, Fifth Edition, Section 8301 Dcsign Criteria and including ASCII 7-10. 1. Wind Speed= 139 mpin Ultimate Wind Speed (vult) and 108 mph (vasd) 2. Risk Category 2 Construction Type = Single Family Residence (V) 3. Wind Exposure = Categoly "C, 4. Internal Pressure Coefficient for enclosed building is .t8 and Height and and Exposrue adjustment Coefficient is 1.40 DETAILS RENJISION SANFORD �F'AR1CD`�� All Dimensions shown are to be Field Verified before Construction Commences D.S. "Vinder" Chehal Lisensed Professional Engineer P.E. 79118 624 Douglas Avenue - Suite 1418 Altamonte Springs, Fla. 32714 (407)227-7368 signature: /o�/y�/2 Sheet 3 of 3 ..�.: 6' x 6' 8" til.. 6' S.G.D. r:: + Simpson H5 ea. Vert. _ 01 /11t _L ,. #5 Rebar with 6" embedment epoxied each end. Grout Fill Cell DE'T'AIL "A" n. t. s. _�rN or - Use (1) HTSM16 tap con to existing block w/ 1/4" x 4" tap cons each end of (2) 2x12's Typ. #5 Rebar with 6" embedment epoxied each end. Grout Fill Cell 2" x 8" Framing For S.G.D. Install ist. Cont. Span Pre -Cast Lintel Above ------ ---- --- L. T New Windows r I'' —Varies #5 Rebar with 6" embedment epoxied each end. Grout Fill Cell DETAIL "B" n.t.S. 12" - #5 rebar pins epoxied 6" into existing CMU Exist. Cont. Span Pre -Cast Lintel Above ----- --------- --New 8" CMU Verify :•I .I 95 Rebar with 6" embedment t e oxied each end. Grout Fill Cell �► #5 Rebar with 6" embedment t. Verify p ::1 ; epoxied each end. Grout Fill Cell 1 CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS' DURING DEMO IF IT IS DETERMINED WATER PROOFING NOTE NOTE: IT 15 THE' RE5PON51BILIT`( OF THE BUILDER TO GOOi?DINATE THE INSTALLATION OF ALL VIATERPROOFING HETFIOD5 NEGE55ARY TO PRO\/IDE A HATER "FIGHT BUILE)06- EN\/ELOPE, REFER TO MFR. INSTALLATION , REGOMMENDATION FOR ALL 5ELEGTED WF)TERPROOFING I -I krERIALS, FLA5HING, DEALERS AND AD -MIX 60MPONENT5. ACTUAL CONDITIONS VARY FROM WFIAT IS SHOWN ON THESE PLANS, CONTRAC'T'OR Is TO NOTIFY E.O.R. FOR FURTHER REVIEW. It is the res onsibilit of the Contractor and Sub -Contractors to Insure that all City, County and or State p Y r I " I noted Kee uirementslCodes/S t,clfications are met and HislHer Responsibility to check with the about, 1 p 1 ld arise. in hal ( '' if nest o s s Agenues q Date: 05-09-2017 CONTRAC"I'UR: PROJECTADDRESS: ITitle of Page: CBI 1511 Elliot Street Seale: NOTED Corinthian Builders, Inc. Sanford, Fla. DETAIL 11C" 11A.S. Note: This Structure has been designed to meet or exceed the Wind load requirements or the 2014 Florida Building Code Residential, Fifth Edition, Section 8301 Dcsign Criteria and including ASCII 7-10. 1. Wind Speed= 139 mpin Ultimate Wind Speed (vult) and 108 mph (vasd) 2. Risk Category 2 Construction Type = Single Family Residence (V) 3. Wind Exposure = Categoly "C, 4. Internal Pressure Coefficient for enclosed building is .t8 and Height and and Exposrue adjustment Coefficient is 1.40 DETAILS RENJISION SANFORD �F'AR1CD`�� All Dimensions shown are to be Field Verified before Construction Commences D.S. "Vinder" Chehal Lisensed Professional Engineer P.E. 79118 624 Douglas Avenue - Suite 1418 Altamonte Springs, Fla. 32714 (407)227-7368 signature: /o�/y�/2 Sheet 3 of 3