HomeMy WebLinkAbout18-4236 (BR18-000970) 1508 W 16TH ST- (A) FLOOR PLANm
IF TI
� i
I
6 II
0110
L 2 >o
I 11 BEDROOM
Iffllmff
i
6
-n4
BEDROOM
CLOS
LIVING
ROOM �)
BEDROOM
I�
2 \2>
�
-EXISTING FLOOR PLAN
1/2 _1'_0"
Plot Style: - - - - Plot Scale: 0.3869:1 Plotted At: Oct. 9, 18 11:08 PM By: KENNY'S DESKTOP Last Saved By: KENNY'S DESKTOP Last Saved At: Oct. 9, 18
HEADER
{2) 2x12 1/2
CDX FLITCH
HEADER --<
STUDS
-FULL LENGTH -
WALL STUDS
-NO CONNECTORS
RQD @ CRIPPLE
L d 11
SIMPSON SP4 W/ (6)
10d x 1-1/2" NAILS
@ BOTTOM OF WALL &
HEADER STUDS
ROOF FRAMING MEMMERS -
CONNECT W/ SIMPSON MTS20
I
``---DOUBLE TOP PLATE
-1/2" OSB OR CDX PLYWD
EXT. SHEATHING NAILED W/
10d GALV. @ 3" O.C. EDGES
& 12" O.C. FIELD
Lu WHEN ATTACHING TO CMU: 2x4
P.T. WALL STUD W/ (4) 5/8"
DIA. ANCHOR BOLTS TO CMU
WHEN ATTACHING TO FRAME:
2x4 P.T. WALL STUD W/ (4
5/8" x 5" LAG BOLTS TO EXT.
FRAME
WHEN ATTACHING TO CMU: 5/8" DIA, x
9" ANCHOR BOLTS, EMBED " MIN. INTO
FOUNDATION W/ 3" x3"x1/8" WASHERS
& DOUBLE NUT, LOCATED WITHIN 6" OF
EA END & 32" O.C. MAX ELSEWHERE.
WHEN ATTACHING TO FRAME:
2x P.T. BOTTOM PLATE W/ 5/8" x 9"
LAG BOLTS @ 32" O.C. W/ SP4 @ 16"
O.C.
MAXIMUM HEADER SPAN (it.)
UP TO
5'-0„ TO
8'--0"
6A
4'-11 1/2"
7'-11 1/
"AND UP
NUMBER OF HEADER STUDS
EXISTING
FIRE DAMAGE SHEET ROCK (WALL AND CEILING).
2.
SUPPORTING END OF HEADER
1
2
3
NUMBER OF FULL LENGHT STUDS
3.
2
AND
AT EACH END OF HEADER
EXISTING
BATH ROOM FIXTURE.
MiNIMUM WALL AND HEADER
STUD REQUIREMENTS
TYPICAL1.
N s
TYPICAL INTERIOR FRAMING DETAIL
DEMOLITION
PLAN
KEY NOTES
PERMIT ISSUED SHALL. BE CONSTRUED TO BE A
6A
1.
REMOVE
AND
REPLACE
EXISTING
FIRE DAMAGE SHEET ROCK (WALL AND CEILING).
2.
REMOVE
AND
REPLACE
EXISTING
DOORS.
3.
REMOVE
AND
REPLACE
EXISTING
BATH ROOM FIXTURE.
4.
REMOVE
AND
REPLACE
ALL FIRE
DAMAGE WOOD FRAME.
5.
REMOVE
AND
REPLACE
KITCHEN
CABINETS
6.
PAINT INTERIOR AND EXTERIOR (TWO COATS)
CONSTRUCTION SPECIFICATIONS
A GENERAL
1. ALL MATERIAL AND WORKMANSHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE
2017 FLORIDA BUILDING CODE 6th EDITION AND ALL OTHER BYLAWS ADMINISTERED BY
AUTHORITIES HAVING JURISDICTION.
2, ALL DIMENSIONS SHOWN ON THE DRAWINGS ARE TO BE VERIFIED BY THE CONTRACTOR
BEFORE PROCEEDING WITH THE WORK.
3. IT IS ASSUMED THAT THE EXISTING CONSTRUCTION IS IN SOUND STRUCTURAL CONDITION.
GENERAL CONTRACTOR IS TO ADVISE THE ARCHITECT IF ANY DISCRIPANCIES OR
DEFECTS ARE NOTED IN EXISTING CONSTRUCTION BEFORE PROCEEDING WITH NEW
CONSTRUCTION.
4. PERFORM ALL ADDITIONAL DEMOLITION WORK AS NOTED ON THE DRAWINGS AND AS
REQUIRED TO PERFORM WORK.
5. CONTRACTOR SHALL EXAMINE SITE, AND BECOME THOROUGHLY ACQUAINTED WITH SAME
AND OBTAIN ANY AND ALL INFORMATION THAT MIGHT BE NECESSARY FOR PROPER
EXECUTION OF CONTRACT. NO AFTER CLAIM SHALL BE ALLOWED OR ENTERTAINED FOR
ANY WORK OR MATERIAL THAT MAYBE REQUISITE AND NECESSARY FOR PROPER
EXECUTION AND COMPLETION OF THIS CONTRACT.
6• WHERE USED, WORD "SUPPLY" SHALL MEAN FURNISHING TO SITE, IN LOCATION REQUIRED
OR DIRECTED, COMPLETE WITH ACCESSORY PARTS.
7. WHERE USED, WORD "INSTALL" SHALL MEAN SET IN PLACE AND SECURE OR AFFIXED
TO BUILDING STRUCTURE AS NOTED OR DIRECTED.
& WHERE USED, THE WORD "PROVIDE" SHALL MEAN SUPPLY AND INSTALL AS DiSCRIBED
ABOVE.
9. __ THE OWNER SHALL HAVE THE RIGHT TO ENTER AND OCCUPY IN WHOLE OR IN PART FOR
THE PURPOSE OF PLACING FITTINGS AND EQUIPMENT OR FOR OTHER USE BEFORE
COMPLETION OF THE CONTRACT IF, IN THE OPINION THE CONSULTANT, SUCH ENTRY
AND OCCUPANCY DOES NOT INTERFERE WITH THE CONTRACTOR IN PERFORMANCE OF
THE CONTRACT.
10. SUCH ENTRY SHALL, IN NO WAY, BE CONSIDERED AS AN ACCEPTANCE OF THE WORK.
11. REPORT ANY ERRORS OR INCONSISTENCIES IN GRADES, LINES, LEVELS AND DIMENSIONS
TO THE ARCHITECT BEFORE COMMENCING WORK..
12 "MAKING GOOD" REQUIRES PATCHING OR REPLACING DAMAGED IN A MANNER EQUAL
TO THAT SPECIFIED FOR NEW CONSTRUCTION.
13. CONTRACTOR IS TO KEEP THE JOB SITE CLEAN AND ORDERLY, WORK AREAS ARE TO
BE FREE OF ALL RUBBISH AND SURPLUS MATERIAL AT ALL TIMES..
ROUGH CARPENTRY
1. INSTALL FURRING AND BLOCKING AS REQUIRED TO SUPPORT FINISHES, CABINETS
AND FIXTURES.
2. PROVIDE WOOD CONTINUOUS BLOCKING BEHIND WOOD TRIM ON CEILINGS AND WALLS
AND TO SUPPOR i EQUIPMENT AND FIXTURES. .
3. PROVIDE ALL BLOCKING AS REQUIRED BY THE WORK.
4. ALL LUMBER AND PLYWOOD SHALL BE IDENTIFIED BY GRADE, STAMPED BY AN
APPROVED AGENCY AS LISTED IN THE LOCAL BUILDING CODE.
5. PROVIDE CUTOUTS FOR PLUMBING FIXTURES, INSERTS, APPLIANCES, OUTLET BOXES AND
OTHER FIXTURES.
C IVIErAL FURRING/GYPSUM DR ALL
1. STEEL STUDS; TO ASTM C 1002 MINIMUM 26 GAUGE C90 GALVANIZED SHEET WITH HOLES
OR KNOCK OUTS FOR SERVICES.
2. PLACE STUDS VERTICALLY AT 24" O.C. AND NOT MORE THAN 2" FROM ABBUTING WALLS
AND AT EACH SIDE OF OPENING AND CORNERS. CROSS BRACE STEEL STUDS AS
REQUIRED TO PROVIDE RIGID INSTALLATION TO MANUFACTURER'S INSTRUCTION.
3. APPLY SINGLE LAYER GYPSUM BOARD TO METAL FURRING OR FRAMING USING SCREW
FASTENERS. MAXIMUM SPACING OF FASTENERS IS 12" O.C.
4. EXTEND PANELS TO UNDERSIDE OF WOOD JOIST UNLESS OTHERWISE NOTED. MAINTAIN
ALL WALL BOARD PANELS 1/2" ABOVE FLOOR TO PREVENT MOISTURE TRANSFER.
5. FILL SCREW HEAD DEPRESSIONS AND JOINTS WITH TAPING/JOINT COMPOUND TO BRING
FLUSH WITH ADJACENT SURFACE OF GYPSUM BOARD SO AS TO BE INVISIBLE AFTER
PAINTING IS COMPLETED.
ACOUSTIC TILE CEILINGS RECORD COPY
1. LAYOUT SYSTEM ACCORDING TO CEILING PLAN. INSTALL WALL MOULDING TO PROVIDE
CORRECT CEILING HEIGHT. FINISH CEILING TO BE LEVEL WITHIN 1:1200.
2. SUPPORT SUSPENSION SYSTEM MAIN RUNNERS 4'-0" O.C. MAXIMUM WITH HANGER WIRE
FROM STRUCTURE ABOVE. COMPLETE ASSEMBLY TO SUPPORT SUPERIMPOSED LOADS,
SUCH AS LIGHT FIXTURES AND DIFFUSERS.
3• SUPPORT LIGHT FIXTURES WITH SUPPLEMENTAL HANGERS WITHIN 6" OF EACH CORNER
AND AT MAXIMUM 24" AROUND PERIMETER OF FIXTURE. INTERLOCK CROSS MEMBER TO
MAIN RUNNERS TO PROVIDE RIGID ASSEMBLY.
4. INSTALL SUSPENSION SYSTEM TO MANUFACTURERS INSTRUCTIONS. INSTALL ACOUSTIC
UNITS PARALLEL TO BUILDING LINES WITH EDGE UNIT NOT LESS THAN 50%4 OF UNIT
WIDTH AND AS SHOWN ON CEILING PLAN.
5. INSTALL FLUSH EDGE MOULDING AT JUNCTION OF ACOUSTIC UNIT CEILING WITH OTHER
MATERIALS AROUND ENTIRE LENGTH OF JOINT. SECURE TO CONSTRUCTION . BUT JOINTS
NEATLY, SQUARE AND TRUE IN ALIGNMENT. REPLACE ANY "T" THAT HAVE BEEN TWISTED,
DENTED OR SCRATCHED.
E PAI NG
1. MAINTAIN ADEQUATE FLOOR AND WALL COVERINGS IN DESIGNATED AREAS AND MAKE
GOOD PAINTERS DAMAGE, PROTECT ADJACENT WORK AND MATERIALS WITH MASKING
AND COVERS, REMOVE ELECTRICAL PLATES, SURFACE HARDWARE ETC. BEFORE
PAINTING. STORE THESE ITEMS AND REPLACE WHEN WORK IN THE AREA IS COMPLETE.
2. SUPPLY TO OWNER ONE SEALED 1/2 GALLON CAN OF EACH COLOR AND TYPE OF
PAINT USED.
3. PREPARED WOOD SURFACES TO CGSB 85 -GP -1M. USE VINYL SEAL OVER KNOTS AND
RESINOUS AREA. PREPARE DRYWALL SURFACES TO ASTM C 36. FILL MINOR
CRACKS WITH PLASTER PATCHING COMPOUND. SAND AND DUST BETWEEN EACH COAT
TO REMOVE VISIBLE DEFECTS.
4. METHOD OF PAINT APPLICATION SHOULD BE GENERALLY BY BRUSH OR ROLLER, THE
USE OF SPAY IS PERMITTED IF SPECIFIED BY MANUFACTURER.
5. APPLY EACH COAT AT THE PROPER CONSISTENCY IN ACCORDANCE WITH THE
MANUFACTURERS DIRECTIONS. DO NOT APPLY FINISHES ON SURFACES WHICH ARE NOT
SUFFICIENTLY DRY.
. TOP AND BOTTOM EDGES OF ALL DOORS SHALL BE FINISHED THE SAME AS THE FACE
OF THE DOOR. INTERIOR WOODWORK WHICH IS TO RECEIVE A PAINT FINISH TO BE
BACKPRIMED WITH ENAMEL UNDERCOATER PAINT.
7. APPLY COAT TO EXISTING CONCRETE FLOORS IN ACCORDANCE WITH THE
MANUFACTURER'S DIRECTIONS.
8. UPON COMPLETION, REMOVE ALL PAINT WHICH HAS SPILLED, SPLASHED OR SPATTERED
ON FLOORS, GLASS METAL OR ANY OTHER WORK AND MAKE GOOD.
F GENERAL ELECTRICAL REOUI S
1. AL WORK SHALL BE DONE ACCORDING TO THE REQUIREMENTS OF THE AUTHORITIES
HAVING JURISDICTION. APPLY, OBTAIN AND PAY FOR ALL PERMITS, FEES.
2. CONNECTIONS, INSPECTIONS, LICENSES, CERTIFICATES OR CHANGES NECESSARY TO
COMPLETE THE WORK SPECIFIED, REPORT TO CONSULTANT ANY CHANGES REQUESTED
BY THE AUTHORTIES. PERFORM ANY CHANGES THAT DO NOT REQUIRE EXTRA
MATERIALS WITHOUT COST TO THE OWNER. PROVIDE ANY ADDITIONAL DOCUMENTATION
REQUESTED BY THE AUTHORITIES. FURNISH FINAL CERTIFICATE OF ACCEPTANCE FROM
THE CITY OF ORLANDO BUILDING DEPARTMENT.
PEP
R.
5A111EQRD BI DING DIVISION
PERMIT ISSUED SHALL. BE CONSTRUED TO BE A
6A
LICENSE TO PROCEED WITH THE WORK AND NOT AS
AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET
b
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING A CORRECTION OF ERRORS IN PLANS,
J\,QING
m
CONSTRUCTION OR VIOLATIONS OF THIS CODE
PEP
R.
s .� r
M
Z K
C.
-
CN Ia
Ln Z
= a
aD
s .� r