Plans Review Sheet
Date: November 2, 2003 Business Address: 2025 W.P. Ball Blvd. 41— V ✓—clo5
Occ. Ch. 36 New Mercantile
Business Name: White Box @ 2025 W.P. Ball Blv .
Contractor: Young Contracting Company Ph. (770) 522-9270
FA . (770) 522-9273
Architect: Phillips Partnership Pho (770) 394-1616
Fax (770) 394-1314
Reviewed [ I Reviewed with comment [XI Rejected 11
Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner ,Pcc
Comment: Plans reviewed as Mercantile Occupancy Class "C". FD reserves right to require
applicable code requirements if occupancy use changes.
Application — New Building. 1493 sq. ft. New Mercantile occupancy
1.1 Mixed — N/A
1.2 Special Definitions — N/N
1.3 Classification of Occupancy — Class "C" (LESS T,AAN 3,000 sq. ft.)
1.4 Classification of Hazard of Contents — Ordinary per 6.2.2.2. F.F.P.C.
1.5 Minimum Construction — N/R (NO SPECIAL REQUIRMENTS)
2.2 Means of Egress Components -isles shall be maintained at all times
2.3 Capacity of Egress — O.K. Less than 40 occupants
2.4 Number of Exits — One (1) See exception #36- 2.4. Less than 75' (ft)
2.5 Arrangement of Egress — O.K., will field verify, per section 7.5>F.EP. C.
2.6 Travel Distance — Shall not exceed 75'36- 2.4.
FIRE PREVENTION
300 N. Park Ave., Sanford, Fl. 32771 / P. O
(407302-2520 / FAX
TMENT
1788, Sanford, Fl. 32772
330-5677
Pager (407) 918-0395
2.7 Discharge from Exits - 44"'isle way through stock room at all times
2.8 Illumination of Means of Egress — O.K.; will fie
2.9 Emergency Lighting — O.K.; will field verify
2.10 Marking of Means of Egress — O.K.; will field
2.11 Special Features — Reserved
3.1 Protection of Vertical Openings — Provide a
3.2 Protection from Hazards — N/N
3.3 Interior Finish — Class `B" "A" or "C" allowed
degree of compartments
WI .Sl
3.4 Detection, Alarm and Communications Systems Not required
3.5 Extinguishing Requirements — as per NFPA 10, one (1) 2,410 B. C. fire extinguishers
required
3.6 Corridors —
4 Special Provisions
- 5 Building Services
5.1 Utilities — as per sec 9-1
5.2 HVAC — as per see 9-2
5.3 Elevators, Escalators, Conveyors (4A-47) N/A
5.4 Rubbish Chutes, Incinerators, and Launc ry Chutes — N/A
Sanford City Code — Chapter 9
Fire Sprinklers;
Monitoring:
Other: NFPA 1
size
3-5.1 Fire Lanes — Not required
3-6.1 Key Box — required
3-7.1 Bldg. Address Number Posted and
2
Post address on building 6" in