HomeMy WebLinkAbout1229 W 13TH PL 03-289 New fire supression permit applicationMY OF SANFORD PERM T it PPLICATION D T -7i Permit No.: Date:: Job Address: Permit Type: —Building _ _ Electrical _ Mechanical _ Plumbing V Fire A Description of Work: C& -k S Qx -r s Additional Infformation for Electrical & Plu iug Permits Electrical: Addition/ ration _Change of Ser ' _Temporar e _Nrw AMP Service of AMPS Plumbing/Res' tial: _Addition/Alterat New Co ction ( e Closet Plus Addid Plumbi Commercial: Number of Fi es_ Number o ater &Sew Dr nag rues_ N r of Gas Lines Occupancy Type; _Residential /Commercial _ Lndu trial Total Sq F Value of `:Nark; S '5 �Q , Type of Construction: Flood Zone:_ Number of 3tories: Number of Dwelling Units: Parcel No.: 35 - - 3 iD - 5 H S - O 13 CD - 02 (Attach Proof of Ownership & Legal Description) Owner/Address/Phone: eWt 0I-(&vL4o FL- • 3-�-825 Con etor/Addres one: LWI2- S[te License N ber: Contact Person: , t e Phone & Fax N ber: Title Holder (If other than Owner): Address: Bonding Company: Address: Mortgage Lender: Address: Architect/Engineer Phone No.: Address: Fax No.: Application is hereby made to obtain a permit to do the work and installations E indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performe to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accun tte and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TOO : YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPR DVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there maybe additiona rest found in the public records of this county, and there maybe additional permits quu water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property £th Signiture of Owner/Agent to SiRna4 of Print Owner/Agent's Name Slgnatur of Notary -State of Florida ate oqa Hyung Keun Kim **My Commission CC853575 July 11, 2003 Owner/Agent is personally Known to Me or _ Produced ID APPLICATION APPROVED BY: Special,Conditions: Print ions applicable to this property that may be from other governmental entities such as of Florida Lien Law, FS 713. 's Name of Florida Date „ �6";; MARY ANGELA BURDETTE ;•"�� Notary Public - State of Florida MYCommWon ExplresSep la 2lb6 Commission # DD148961 •„oat; g^,.•' Bonded By National Notary Assn. ID or Date: /O 7":�2 6' � U Z n CITY OF SANFORD FIRE FEES FOR SER` PHONE # 407-302-1091 * FA DATE: O o? O a - BUSINESS NAME / PROJECT: PHONE NO.: FAX CONST. INSP. [ ] C / O INSP.:[ ] EIN F. A. [ ] F.S. [ ] HOOD [ TENT PERMIT ] TANK PERMIT ] 0l3 TOTAL FEES: $ _ '5 COMMENTS: //0'0 c Sys Te, �. Address / Bldg. # / Unit # 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. ARTMENT : #: 407-330-5677 PERMIT #: D'3- 24301 rg� II PLANS REVIEW 1'1' )TH [ ] BURN PERMIT [ ] (PER UNIT SEE BELOW) Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Pork Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Preventio division before any further services can take place. I cern that the above is true and correct and that I will comply with all applic^codes and ordinances of the City of Sanford, Flo¢ida.I Sanford Fi Y, revention Division 4, 6LI.. Photo is not available. De Dell" Baa., - u„anw vl r Zass r 46 as n z NS E M I N C O U N La�n/gw�md rooperty Information County: Seminole County ucel 1D: 36 19 30 SAJ OB00 0220 MLSM Lst Sale: $100.00 AltKey/Folio Ile Date: 0611412002 op. Address: -1307 4 ity/State: SANFORD,FL}z `/ N/3f%) Zip Code: j 32771-2769 ail Carrier Rte: C006 Census Tra 121170204.01 9r Name: LUCY O CHO Co -Owner mg Address: 2419 PEWTER CT 535 VIA DEL ORO DR, ALTAMONTE SF State: ORLANDO, FL Zip Code: Carrier Route: $27,276.00 Wee Owner: No 32937 JULIANA KIM 1 Description: LEG N 1l2 OF LOT 22 BILK B SOUTH SANFORD PB 1 PG 94 (Plat Book / Page: 000110094 35 Twp: 19 Rng: 30 Subd #: SAJ Blk: o600 Lot: 00 Gvision: SOUTH SANFORD Parcel # (Polk Co.): 1 Value: $3,061.00 roved Value: 524,194.0o I Value: $27,276.00 Value: $27,276.00 nption Description: my Use Code: 11 e Use Code: 11 III Dim Type: FF Dimensions: so.00 X 7o.00 d Acreage: rooms: Bath: 11 Tax Amo t: $666.66 Tax Year: 11 2001 Millage : 21A7 County Use Descri State Use Desc: Zoning: Year Built: Effec Yr Blt Num Buildings: 1 Building Num: 1 Stories: i STORES GENERAL -ONE STORY 1. ONE STORY Bldg Gross Area: 3,004 Bldg Hid Area: 3,004 Bldg Net Area: 3004 Wall: Wall: or Finish: Unit Location; Unit Floor: Unit View: Unit Number: 3,004 )ate Price OR Book/Page Deed Type Owner's N, Ld&l Part Mtg. Type Mtg. Amt. Mtg. Company 611412002 $100 4435-0283 QUIT CLAIM DEED CHO, LUCY 0126/2001 $22,000 4207-0728 WARRANTY DEED CHO, LUCY 2/01/1996 $100 3030-0043 AGREEMENT FOR DEED GI% 9/0111995 $100 2969-1511 PERSONAL REP'S DEED 510111984 $100 1546-1870 AGREEMENT FOR DEED endor ID: 121170010275 arcel ID: 3519 30 5AJ OB00 0220 Mtg. Book/Page Int. MARY A ��� � �:. .r:. .;'.• �. i.`l: a - �?Li �. , tC . ir'.. :iln"- .. -.:ice k _ - ,. .`i 'f -iii: _ 'a. v.. 1 � ��__... __. _ _ ._ _ ... _ __ ..__... - ;;"-IRECHEK FIRE PROTECTION COMPAN" PRc L3E2c'7- NAME SANFORD 13UILDING DEPT. THESE FLANS ARE REVIEWEO AND CONDITIONALLY ACCEPTED FOR PERMIT. A PERMIT ISSUED SHALL SE CONSTRUED TO SEA LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER, TE SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL DISSUANCE OFA PERMIT PREVENT THC BUILDING ON OF�M THEREAFTER REQUIRING A CORD NG OR O ERRORS ON THE P'EQU" CONSTRUCTION THER VIOLATIONS OF THE CODES. oC r--(�oi> VZ� vqe:5T 13�-t�> - �nl A "EKP v,1 e7k " cp'sl-n�c-4. GAO sv WAIT # 03-2�1 OFFICE COPY 2701 W. 5th Street • Sanford, Florida 32771 )407) 324-0201 • Fax )407) 324-0214 F• . �: ,'. �,`\ i _ �_ \�/ �� �' � _ �. , _ - ...- _ ,'� ,'f'.. .. .. _ __ fSkCTION SYSTEM DESIGN MANUAL P/N: 12385 AMEREX KP RESTAURA FIRE SUPPRESSION SYSTEM Tested and List Underwriters Lab( to UL Standa,rc Effective, Nov. 21 EX 4658 MAY 1, 1995 d by •atories 300 1994 N S Y S T E M D E S 1 G N X11 41 AY 1, 1995 Sction IV .Design , xPage r -'1 AinerexUKP 375?WeYChemic6hSysf4ri (EXi4658) I SYSTEM DESIGN It is essential that any Pre -Engineered Restaurant, Fire Suppres�.pn system be properly designed, sized and installed. This section covers the design aspects of the AmerexRestaurant system. The following Items will be addressed in this section: I Nozzle Placement Limitations Determining Agent Quantity Actuation Network Limitations Distribution Piping Network Limitations Detection Network Limitations Manual pull station Limitations Mechanical Gas Valve Applications n k+r� Electric Gas Valve Applications Microswitch Limitations TYPICAL SINGLE CYLINDER SYSTEM LAYOUT DD�t 0000 RDZZ� V RµDF PAN FRPAN R L BAS The Amerex KP Restaurant system has been tested in accordance with U.L. Standard 300 using live fire tests. These systems have been proven to be successful hen designed and installed within the limita- tions established in this manual. Sketches and/or drawing# should be made of the system design for reference during the installation phase. At final testing, th se drawings shall be updated to "As - Builts" and a copy placed in a permanent Job File for future referdnee. DUCT PROTECTION LIMITATIONS: SINGLE NOZZLE The Amerex Duct Nozzle (P/N 11985) is listed to protect Restaurant Cooking ducts of unlimited length up to 75 perimeter inches (190.5 cm) [or 24 diameter inches (60.9 cm)) using one nozzle. The nozzle has two flow points and must be centered within the duct, placed 2 - 8 in. (5.08 - 2( into the duct opening and aimed at the center of the cross the duct. Note: In no case shall the diagonal dimension of the duct exceed 28 inches without additional duct nozzles. q 1985] of 2A + 2B = 75 Perimeter Inches (190.5 cm) Maximum rJ "y � .. �. :.aa.2: ,'X .. � i. Se ctil n TVDesign Page N - 2 Amer(-x KP_. 75 Wet Chemical System (EX4658)', TRANSITION LIMITATIONS - SIN .LE NOZZLE [P/N: 11985] 1 A transition is a section found on some exhaust systems between the hood and the duct. One Amerex Duct Nozzle (P/N 11985) will protect a transition at the point where the transition is 75 perimeter inches (190.5 cm) or less or a diameter of 24 inches (60.9 cm) or less. The nozzle has two flow points and must be placed in the center of the opening at the point where the perimeter inches are 75 (190.5 cm) or less or where the diameter inches are 24 (60.9 cm) or less and aimed at the center of the cross section of the duct. Additional duct protection is not required when using this method. C OF VERTICAL DUCT - — - —� OF HORIZONTAL DUCT Hood AIM POINT Duct Nozzle I VER- CA_ / HORIZONTAL DUCT -RAN SI TIONS Special Note: For Ducts with Vertical / Horizontal Transitions reference the diagram above with respect to nozzle aim. DUCT PROTECTION LIMITATIONS-TWO'NOZZLES [TWO X Two Amerex Duct nozzles ((P/N 11985) will protect ducts with a perimeter of 76 to 125 inches (193 - 320 cm) or a maximum diameter of 48 inches (121.9 cm). To correctly position the nozzles, a rectangular duct should be divided along its longest side into four equal distances. A circular duct should be divided along a centerline into four equal distances. A nozzle should be placed at one quarter of the ducts width (or diameter) and at three quarters of the ducts width (or diameter) with both nozzles on the center line, placed 2 - 8 inches (5.08 - 20.32 cm) into the duct opening and aimed at the center of the cross section of the duct. Each nozzle has two flow points. Note: In no case can the diagonal dimension of each module exceed 28 inches (71.12 cm) without adding additional duct nozzles. Maximum perimeter inches of each module cannot exceed 75 perimeter inches. MAY 1, 1995 11985; ,;. ., .-.. � -�-- .. r _T �. � :�. q I AY 1,1999 r DUCT PROTECTION LIMITAT16NS: SQ in. Perimeter 1Yx FLOW POINT NOZZLE [P/N: 11983] The Amerex Solid Fuel Appliance/ Duct Nozzle [PM: 11983] is listed to protect Restaurant Cooking Exhaust Ducts of un- limited length and up to 50 perimeter inches (127 cm) or 16 diameter inches (40.6 cm) using one nozzle. The nozzle has one and one-half flow point and must be located in the center of the duct opening and placed 2-8 inches (5.08 - 20.3 cm) into the duct opening and aimed straight up for vertically run ducts. Note: In no case can the diagonal dimension of the duct exceed 18.8 inches (47.8 cm) without adding additional duct nozzles. CAUTION: DO NOT MIX THE USE OF DUCT NOZZLES P/N: 11983 AND P/N: 11985 WITHIN THE SAME DISTRIBUTION NETWORK. DUCT PROTECTION LIMITATIONS: 100 inch Perimeter TWO - 11/2 FLOW POINT NOZZLES [P/N: 11983] The Amerex Solid Fuel Appliance / Duct Nozzle [P/N: 119831 is listed to protect a Restaurant Cooking Exhaust Ducts of unlimited length and up to 100 perimeter inches (254 cm) or 32 diameter inches (81.2 cm) using two nozzles. The nozzles total three flow points and to properly position the nozzles, a rectangular duct should be divided along its longest side into four equal distances. A circular duct should be divided along its center line into four equal distances.The nozzles are to be placed at one quarter and three quarters position of the duct width (or diameter) with both nozzles on the center line, placed 2 - 8 inches (5.08 - 20.3 cm) into the duct opening and aimed straight up in a vertically run duct. Note: In no case can the diagonal dimension of the duct exceed 37.2 inches (94.4 cm) without adding additional duct nozzles. CAUTION: DO NOT MIX THE USE OF DUCT NOZZLES P/N: 11983 AND P/N: 11985 WITHIN THE SAME DISTRIBUTION NETWORK. e-` ir% " .Design .� �:,�Page 1V - 2A Am Fez p375 Wet Chemical'Sys, `m '(EX 4658) 2A + 2B = Perimeter Inches Maximum Section IV Design Page :IV -2B Amerex KP-?7.5:Wet ChemicahSystemra(EX:4658)-;j DUCT PROTECTION LIMITATIONS: 150 in. Perimeter THREE 11/2 FLOW POINT NOZZLES [P/IV: 11983] The Amerex Solid Fuel Appliance / Duct Nozzle [P/N: 119831 is listed to protect Restaurant Cooking Exhaust Ducts of unlimited length and up to 150 perimeter inches (381 cm) or 48 diameter inches (122 cm) using three nozzles. The nozzles total four and one-half flow points and to properly position the nozzles, a rectangular duct should be divided along its longest side into six equal distances. A circular duct should be divided along its center line into six equal distances, The nozzles are to be placed at one sixth, one half and five sixths positions of the duct width (or diameter) on the center line, placed 2-8 inches (5.08 - 20.3 cm) into the duct opening and aimed straight up for vertically run ducts. NOTE: In no case can the diagonal dimension of the duct exceed 55.9 inches (142 cm) without adding additional duct nozzles. CAUTION: DO NOT MIX THE USE OF DUCT NOZZLES P/N: 11983 AND B P/N: 11985 WITHIN THE SAME DISTRIBUTION NETWORK. A 2A + 2B - NOZZLE LOCATIONS AND AIMING FOR HORIZONTALLY RL The nozzles are to be located on the centerline of the vertically run duct, 2 - 8 inches into the duct. The aiming point is to be a point 3 inches above the base of the horizontally run duct and In the same verticle plane of the nozzle. See illustration. TRANSITION LIMITATIONS - SINGLE NOZZLE [P/N: 11983] met DUCTS MAY 1, 1999 OF VERTICAL DUCT E rAIM s INT Dum No=!* / HORIZONTAL DUCT TRANSITIONS OF HORIZONTAL DUCT A transition is a section found on some exhaust systems bet en the hood and the duct. One Amerex Solid Fuel Appliance / Duct Nozzle (P/N: 11983) will protect a transition at he point where the transition is 50 perimeter inches (177 cm) or less ora diameter of 16 inches (40.6 cm) or less.Tho nozzle has 11/2 flow points and must be placed in the center of the opening at the point where the perimeter inches ar 50 (127 em) or less or where the diameter inches are 16 (40.6 cm) or less and aimed at the center of the cross sedtioof the duct. Additional duct protection is not required when using this method. (REFER TO PAGE I11-2 FOR PICTORIAL .. �, ._ ., T :� � � �'' k _ MA,Y 1, 1999 DUCT PROTECTION LIMITATIbNS - _+ MULTIPLE NOZZLES: When protecting ducts larger than 150 perimeter inches (380.7 utilizing the 11h flow point nozzle [P/N: 11983], the perimeter is divided by 50 (126.9). The resulting number must be rounded up to the next whole number. This equals the minimum number of duct nozzles that must be used. The cross sectional area of the duct is then divided into the same number of B equally sized modules. The duct � nozzle is then located in the center B of each module. 2A+2B = Perimeter Inc Note: In no case can the diagonal dimension of each module (76.2 cm) without adding additional duct nozzles. See Aiming Not - Page IV - 2B PLENUM PROTECTION LIMITATIONS - SINGLE FLOW POINT NOZZLE [P/N: 11982] The Amerex Appliance, Plenum Nozzle (P/N 11982) is capable protecting plenums up to 10 feet (3.048 m) long with either a single inclined filter bank or a "V" bank filter arrangement. The filter height cannot exceed 24 inches (60.96 cm). Each plenum nozzle uses one flow point. The nozzle must be positior 4 inches (10.16) maximum from the wall, aimed horizontally an positioned down 1/3 the filter height from the top of the filter. "V" Bank Protection IM TOP OFTHE F1I CENTEREDIN 'Y' BANK -V-BANK E I' LL, TE 30 inuimb Single Bank Protection 113 FILTER HEIGHT --r FROM THE TOP OF THE FILTER. ON CENTER BETWEEN 1 BIDE WALL AND FILTER 0* mt 1A�N9bl NO BE TE 0 • LOCATEDO4- F FROM END WALL CENTERED ONTHE FILTER r _ _..... .. a.. _'� - T � � F' . i -. Secti,in lv :Design 04' Amerex KP -G75 LWet,Che"mical S s em Ek PLENUM PROTECTION - MULTIPLE NOZZLES: Plenums exceeding 10 feet (3.048 m) in length may be protected by using multiple plenum nozzles. Each nozzle must be protecting an area no more than 10 feet in length. Nozzles may be positioned facing each other as long as the entire plenum area is being covered. Nozzles may not face in opposite directions from a common tee. INCORRECT )T PERMITTED) MAY 1, 1999 r� _ t _ .�� J �.' APRIL 15. 1996 :.Design; Page:IV - 5 1 -. i...,.ay. �,•�;:�vji,v,.. .va:.v,•vaassa..w FRYER PROTECTION (FULL VAT) TWO FLOW POINT NOZZLE [P/N: 1,3729] MAXIMUM AREA: 191/2 In. (50 cm) X 25 We In. (65 cm) [including di ainboard interface area] 191/2 In. (50 cm) x 19 In. (48 cm) [not including d inboard interface area] Amerex Fryer Nozzle (P/N 13729) uses two flow points and will pr tect a full vat fryer. It the fryer does not include a drainboard, the maximum fryer dimensio s for single nozzle coverage are 19" x 191/2" and the maximum protected area is 2.53 ft' ( 350 cm2). If the fryer does contain a drainboard, the maximum fryer dimensions for single n zzle coverage are 25 3/8" x 191/2" and the maximum protected area is 3.44 ft2 (3195 cm2) However, the maximum hazard- area must not exceed f 91/2" x 19". The nozzle must a located along or anywhere within the protected area. Nozzle heights must be within 36 48 inches (91.44 - 121.92 cm) above the appliance surface and aimed to the cer I er of the hazard area of the appliance. ---'79' Locate nozzle within shaded area 19 �* (above the protected area) f � AIM POINT (CENTER OF AREA) � I Front 48' 360 FULL VAT FRYER ' WITHOUT DRAINBOARD 48' Note: Max. & Min. heights must be measured vertically from the tip of nozzle to the top of the appliance. FULL VAT FRYER WITH DRAINBOARD Note: Max. & Min. heights must be measured vertically from the tip of nozzle to the top of the appliance. FRYER PROTECTION (SPLIT VAT) TWO FLOW POINT NOZZLE [P/N: 13729] MAXIMUM AREA: 14 In. (35.56 cm) x 21 In. (53.34 cm) [includin drainboard interface area] 14 In. (35.56 cm) x 15 In. (38.1 cm) [not includi ng drainboard interface area] The Amerex Fryer Nozzle (P/N 13729) uses two flow points and will rotect a split vat fryer If the fryer does not include a drainboard, the maximum fryer dimen ions for single nozzle coverage are 15" x 14" and the maximum protected area is 1.46 ft2 356 cm2). If the fryer does contain a drainboard, the maximum fryer dimensions for singl nozzle coverages are 21" x 14" and fhe maximum protected area is 2.042 ft2 (1897 cm2'). lowever the maximum hazard area must not exceed 15" x 14". The nozzle must be located within the protected area on a line perpendicular to the longest side of the fryer passing I irough the center of the hazard area. Nozzle heights must be within 40 to 50 inches (1 1.6 - 127 cm) above the appliance surface and aimed to the center of the hazard area of he appliance. Locate nozzle within shaded area (above the protected area) - ArM POINT I (CENTER OF HAZARD AREA) h, i 1 i Front 50, 4 ' SPLIT VAT FRYER WITNfII 1T npAINRf1Aprl �a 1 50' 40 - SPLIT VAT FRYER WITH DRAINBOARD Note: Max. & Min. heights must -�• be measured vertically �a+• from the tip of nozzle to the top of the appliance Section rV` .-Design.. Page:Iy.:- 5A Amerex KP -375 W.et.Chemical System, .(EX 4658) LOW PROXIMITY APPLICATION FRYER PROTECTION (FULL VAT) TWO (2) SINGLE FLOW POINT NOZZLE [P/N: 1198 MAXIMUM AREA: 191/2 In. (50 cm) X 25 3/8 In. (65 191/2 In. (50 cm) x 19 In. (48 cm) A pair of Amerex Single Flow Point Nozzles (P/N 119E must be used in pairs located on the perimeter of the the appliance and within a zone extending 6" in both ( nozzles are to be located 180° apart (directly across fr point 3" below the top of the appliance and directly be not include a drainboard, the maximum fryer dimensio tected area is 2.53 ft2 (2350 cm2). If the fryer does cot dimensions are 25 3/8" x 19%2" and the maximum prot the maximum hazard area must not exceed 191/2" x 1 c to 36 inches (44.45 - 91.44 cm) above the appliances MAY 15, 2000 m) [including drainboard interface area] -lot including drainboard interface area] �) will protect a full vat fryer. The nozzles ppliance, 1/2" back from the inside edge of rections of the center of the hazard. The m one another). They are to be aimed at a )w the opposing nozzle. If the fryer does is are 19" x 19'/2" and the maximum pro - lain a drainboard, the maximum fryer acted area is 3.44 ft2 (3195 cm2). However, . The nozzles height must be within 17 1/2 Irface. Note: Max. & Min. heights must be measured vertically from the tip of nozzle to 36 ` the top of the appliance. i 1 I, °A 17'1/20 ! 6's 1 tion �( 6 •, 'S AIMING POINT i FULL. VAT FRYER WITH DRAINBOARD MAY 15, 2000 l It SINGLE BURNER RANGE PROTECTION ONE - 1/2 FLOW POINT NOZZLE [PIN: 119841 The Amerex Half (1/2) Flow Point Nozzles (P/N 11984) will rotect a single burner with a surface area of 18" x 18" (45.72cm x 45 2cm). The nozzles must be located on the perimeter of the burne and 20 to 24 inches above the burners surface. The nozzle is aimed t a point 7" above the center of the burner. SINGLE BURNER RANGE PROTECTION - OV ONE - 112 FLOW POINT NOZZLE [PIN: 119841 The Amerex Half (1 /2) Flow Point Nozzles (P/N 11984) wi single burner with a surface area of 18" x 18" (45.72cm x nozzles must be located directly above the center of the t to 42 inches above the burners surface. The nozzle is air center of the burner. TWO BURNER RANGE PROTECTION - SINGLE FLOW POINT NOZZLE [P/N: 119821 The Amerex Appliance, Plenum Nozzle (P/N 11982) ha will protect a range surface area of 14 inches X 28 inch 71.12 cm). The center to center distance between burr exceed 14 inches. The nozzle must be located 44 - 48 i (111.8 - 121.9 cm) above the range surface and center the two burners. The range surface area is measured f outside of the burner to the outside of the burner. 18' 20" l 1-8w 24" protect a ! 5.72cm). The mer and 24 ( 42" )d at the one flow point and 28' 5(35.56cmX r rs must not between i the Note: Max. & Min. h ' is must be mea=ed die tip of nozzle to the ace of the appliance. -Sect; on.N I3es n ~ " erext Kf?5 seta _ l FRYERS EXCEEDING SINGLE NOZZLE PROTECTION: Muftiple Amerex Fryer Nozzles (P/N: 13729) may be used to pr single vat fryers with maximum protected areas exct.,eding sing coverages up to a maximum protected area of 6 ft2. The fryer rr divided into modules for single nozzle coverages and the nozzl and aimed for each module as indicated for single nozzle cove modules that do not include drainboards, the maximum module for single nozzle coverages is 191/2" x 19" and the maximum pr is 2.53 ft2 (2350 cm2}. If the module does contain a drainboard, module dimensions for single nozzle coverage is 25 3/8" x 19% maximum protected area is 3.44 ft2 (3195 cm2). However, the frying area of a module must not exceed 19'/2" x 19". FOUR (4) BURNER RANGE PROTECTION: TWO (2) FLOW POINT NOZZLE [P/N: 141781 The Amerex 4 Burner Range Nozzle (P/N: 14178) has two (2) points and will protect a range surface area of 24 inches x 24 (60.96 cm x 60.96 cm).The center to center distance between must not exceed 12 inches. The nozzle must be located 18 - (45.7 cm - 127 cm) above the range surface and centered bet the burners. The nozzle is aimed straight down at the center appliance. Note: Max. be me of no tate RANGE PROTECTION - MULTIPLE NOZZLES [P/N: 14178] For ranges that have a surface area exceeding the capabiiiti single nozzle, multiple nozzles must be used, provided that: The surface area of the range is divided into equally modules. Each module must be equal to or less thar inches x 24 inches (60.96 cm x 60.96 cm). Note: When using this nozzle to protect a two (2) burner Range, the aiming point is where an 8.50" Radius from the center of each burner -crosses one another. s� PROTECTION OF BACK SHELVES Confronted with a back shelf which obstructs the spray patt of the protecting nozzle? Locate the nozzle so that it is bek shelf and still within its listed minimum. When the shelf inter with the proper nozzle orientation, it may be necessary to r the pipe under the shelf or provide a hole in the shelf for th+ Always receive agreement on shelf alterations before pf the work. ect vat st be Ig ocated es. For imensions ected area he maximum and a ximum f low fiches burners ) inches the SEPT. 1 5, 1997 Min. heights must cured from the tip le to the surface of of a ized ,ci- 1 AIM POINTS i NOZZLE PN1 x178 -1 T4 f BA i< ---- i 1• r the 1p" 1J1Ni1f1}M :res NOZZLE HEIGH' - Ae nozzle. .orming Poup BURNER RA\O_ .. .. ,�; . , :- _ , t t �. � ; , � . 'ARRfL 152 1995 RANGE PROTECTION - SINGLE FLOW POINT NOZZLE [P/N: 11982] The Amerex Appliance, Plenum Nozzle (P/N 11982) has one flow point and will protect a range surface area of 12 inches X 24 inches (30.48 cm X 60.96 cm). The center to center distance between burners must not exceed 12 inches. The nozzle must be located 36 - 50 inches (91.44 - 127 cm) above the range surf and centered between the two burners. The range surface area is measured from the outside of the burner to the outside of the burner. Note: Max. & Min. heights be measured from t of nozzle to the sur the appliance. RANGE PROTECTION - MULTIPLE NOZZLES [P/N: 11982] For ranges that have a surface area exceeding the capabilities of a single appliance nozzle, multiple nozzles must be used provided that: The surface area of the range is divided into equally sized modules. Each module must be equal to or less than 12 inches X 24 inches (30.48 cm x 60.96 cm) Note: Max. & Min. heights be measured from t nozzle to the surfac appliance. WOK PROTECTION SINGLE FLOW POINT NOZZLE [P/N: 11982] The Amerex Appliance, Plenum Nozzle (P/N: 11982) has one flow point and will protect a wok with dimensions between a minimum diameter of 14 inches (35.56 cm) and a maximum diameter of 24 inches (60.96 cm) inclusive. The wok must have a height dimension between a minimum of 4 inches (10.16 cm) and a maximum of 7 inches (17.78 cm) inclusive. The nozzle must be centered over the center of the wok and located at a height between 40 inches (101.6 cm) and 50 inches (127 cm) from the bottom of the inside of the wok and aimed at the center of the wok. of tip of of the 24" 14" max. min. Min. Size —L Max. Size 4" min. \,.�rlmax. I Aim Point 50" max. i i 40" max. �:_ �. _:_ ..- . � i - .��''. Section IVVt fl AmerexKP-375Wet'Chemiba'( t ZE0j�ri6 8) GRIDDLE PROTECTION - I , SINGLE FLOW POINT NOZZLE [PM 119821 The Amerex Griddle Nozzle (PM 11982) has one flow point and will protect a griddle surface of 36 inches wide (91.4 cm) X 30 inches deep (76.2 cm). The nozzle must be located along the perimeter of the appliance and within a vertical height range from 30" to 48" above the surface of the appliance. The aiming point for the nozzle is the "point of intersection" of a straight line from the nozzle location to the center of the appliance, with an 11" square, generated about the center point of the griddle. 11" Square Centered on Griddle C Perimeter of Griddle — 48' max. mzx. i\i j 2?y_30" min. ��14� riX 11'Square Centered on Griddle Center Note: Me' 8 min. heights must be mea red from the tlp of the no verdcelly to the surface of of Intersection NIM POINT Nozzle Location GRIDDLE PROTECTION MULTIPLE SINGLE FLOW POINT NOZZLES [P/N 11982] Multiple Amerex Griddle Nozzles (PM 11982 - one flow point) may be used to protect a griddle surface area greater than 30 Inches (76.2 cm) X 36 inches (91.4 cm). The griddle must be divided into modules for single nozzle coverages and the nozzles located and aimed for each module as indicated for single nozzle coverage. 11" Square Centered on Griddle Center Nozzle Location Single Module max. I Griddle les 4 POINT Is protez module APRIL 15, 1996 48' max, x' i Centered on Griddle Module Note; Max. 8 min. heights must be measured from the fip of the nozzle verth allf, to the surface of theappriance. 48' � 30' 11'Squar, Centerea on Griddle Center `r _ •. � ' s. �:AP.RIL 15, 1996 GRIDDLE PROTECTION - OVERHEAD TWO FLOW POINT NOZZLE [P/N 13729] The Amerex Fryer and Griddle Nozzle (PM 13729) has two flow points and will protect a griddle surface of 42 inches wide (106.7 cm) X 30 inches deep (76.2 cm). The nozzle must be located within 6 inches (15.2 cm) of either side of the appliance centerline, placed 38 inches (96.5 cm) to 50 inches (127 cm) above the cooking surface and aimed straight down. GRIDDLE PROTECTION - OVERHEAD MULTIPLE TWO FLOW POINT NOZZLES: [P/N: 13729] Griddles exceeding 30 inches (76.2 cm) X 42 inches (106.7 cm) may be protected using multiple two flow point nozzles by dividing the surface area into equal modules. Each module requires one nozzle and cannot exceed an area larger than 42 inches wide (106.7 cm) X 30 inches deep (76.2 cm). Note: Max. & min. heights must be measured from the tip of the nozzle vertically to the surface of the appliance. N 12-'x%12-- hL 6 min, heights must be Measured from the tip of the ozde vertitxik to the surface of he appliance. 658) , 7. 1 i I Section Anne MAIN S'ee igi ma$ UPRIGHT BROILER PROTECTION: TWO HALF FLOW POINT NOZZLES (P/N: 11984) Two Amerex Upright Broiler Nozzles are required for this application. Each Upright Broiler Nozzle (PM: 11984) equals a 1/2 flow point. These nozzles must always be used in pairs equalling one flow point and will protect an internal broiler chamber measuring 30Y2" X 281/2" (77.47 cm X 72.39 cm). The nozzles must be positioned at the front opening of the broiler with the top nozzle located above the grate, aimed toward the opposite rear comer and the lower nozzle located below the grate and aimed toward the center of the drip pan. Note: A maximum of four (4) Upright Broiler Nozzles may be used per agent cylinder. ELECTRIC RADIANT CHARBROILER PROTECTION, SINGLE FLOW POINT NOZZLE [P/N: 11982] Note: Electric charbroilers with a non -grated surface or a solid ribbed surface may be protected using the same limitations as a griddle. Electric charbroilers with an open grate may be protected with one Amerex Appliance, Plenum Nozzle (P/N 11982) provided that the area is no larger than 20th inches X 24 inches (52.07 cm X 60.96 cm). The nozzle uses one flow point and must be located within 18 - 36 inches (45.72 - 91.44 cm) above the grate surface, anywhere along or within the perimeter of the protected area, aimed towards the center. -Pr, etaun fWONT NEW APRIL 15, 1995 SIDE NEW Note: Mea. 8 Min. heights must oe measured from the Up of nonle to the center of the cooking surface 36" 18" r , - � ,�. 2 'MAY 11 1999 1 - It. GAS RADIANT CHARBROIL&I PROTECTION SINGLE FLOW POINT NOZZLE [P/N: 11982] One Amerex Appliance, Plenum Nozzle (P/N 11982) will protect a gas radiant charbroiler with a cooking surface measuring 201/2 inches X 24 inches (52.07 - 60.96 cm) maximum. The nozzle uses one flow point. It must be located 18 to 36 inches (45.72 - 91.44 cm) above the cooking surface and anywhere along or within the perimeter aimed towards the center. LAVA ROCK (CERAMIC/SYNTHETIC) CHARBROILER SINGLE FLOW POINT NOZZLE [P/N: 119821 <, 1o4, A single Amerex Appliance, Plenum Nozzle (P/N 11982) will protect a lava rock charbroiler with a maximum cooking surface of 201/2 inches wide (52.07 cm) by 24 inches deep (60.96 cm). The appliance nozzle uses one flow point and for this application must be located between 18 to 36 inches (45.72 to 91.44 cm) above the cooking surface, anywhere along or within the perimeter of the appliance, aimed towards the center. tion N Design Page Iv - 8C . z � Y 6i� KP=375 �We .Chemieal:Svstem --.'(EX-4658) AIM @ @ ,DINT / 36' 18,P I Note: Max. & Min. heights must be measured from the tip of nozzle to the cooking surface of the appliance. Note: Max. & Min. heights must be measured from the tip of nozzle to the cooking surface of the appliance. 3�,.'"T�a. ,r�s�1828Td,�' y ea��•, a�"':�M8�7Cr-tett[ f1S "` ,,�ri i�'_ � F�QtYiNt�s3.' Duct 48 in. (121.8 cm) Di eter 3- 11983 4'A 32 in. (81.2 cm) Dia ter 2-11983 3 16 in. (40.6 em) Dia eter 1-11983 1 % 24 in. (60.9 cm) Dia ter 11985 2 150 In. ( 381 cm) Pe ter 3-11983 4% 100 in. ( 254 cm) Pe ter 2-11983 3 50 in. (127 cm) Peri ter 1-11983 114 7S in. (190.5 cm) Pe ter 11985 2 Plenum 10 ft (3.05:m) - L gth 11982 1 Fryer (with Drainboard) 19% x 25 318 in. (48.26 64.45 cm) 13729 2 Griddle 30 x 48 in. (76.2 x 1249 cm) 14178 2 30 x 42 In. (76.2 x 1C4.7 cm) 13729 2 30 x 36 in. (76.2 x 9 4 cm) 11982 1 Range 12 x 24 in. (30.48 x 96 cm) 11982 1 24 x 24 In. (60.96 x 6 96 cm) 14178 2 Upright Broiler 30% x 28% in. (77.47 x 2.39 cm) 2-11984 2 x % Electric Radiant 20% x 24 in. (S2.07 x .96 cm) 11982 1 Gas Radiant 20% x 24 in. (52.07 x .96 cm) 11982 1 Lava Rock Broiler 20% x 24 in. (52.07 x .96 cm) 11982 1 Wok 14 in. 0 (4 in. Depth) 24 In. 0 (7 in.'Depth 11982 1 Charcoal - Natural 6 Mesquite 24 x 28% in (60.96 72.4) 11983 114 Mesquite - Chips 8 Chunks 24 x 28% In. (60.96 72.4) 172.4) 11983 1 K Mesquite Logs 24 x 28% in. (60.96 11983 1'A AGENT QUANTITY AND CYLINDER SELECTION: After reviewing the hazards and determining the number and tyrie of nozzles that will be required, the quantity of agent and the number and type of cyl;riders must be selected. Add, g the number of flow points that are needed for the system will determine the agent quantity and cylinder options One 3.75 Gallon Cylinder (P/N 13334) will supply sufficient agent for up to and including 11 flow points. 1,ylinders may be used together for multiple cylinder systems with one Mechanical Release Mechanism. A maximu I i of 10 Agent Cylinders may be used per Mechani- cal Release Mechanism. secciori Iv Design Page,IVT,8D, Amerex KP -371" Wet' Che'rnical'System ti'(EX"4658) NATURAL AND MESQUITE CHARCOAL CHARBROILER PROTECTION ONE AND ONE HALF (11/2) FLOW POINT NOZZLE [PM: 11983] One Amerex Solid Fuel Appliance Nozzle (P/N: 11983) will protect a Charcoal Charbroiler with a cooking surface measuring 28'/2 inches x 24 inches (72.4 cm x 60.96 cm) maximum. The nozzle uses one and one half flow points. It must be located 16 to 42 inches (40.6 cm - 106.7 cm) above the cooking surface and anywhere along or within the perimeter aimed at the center. The fuel depth is limited to 6 inches maximum. MESQUITE CHIPS & CHUNKS CHAREIROILER ONE AND ONE HALF (11/2) FLOW POINT NOZZLE [PM: 11983] A single Amerex Solid Fuel Appliance Nozzle (PM: 11983) will protect a mesquite charbroiler with a maximum cooking surface of 261/2 inches x 24 inches (72.4 cm x 60.96 cm). The nozzle uses one and one half (1Y2) flow points and for this application must be located between 16 to 48 inches (40.6 cm to 121.7 cm) above the cooking surface anywhere along or within the perimeter of the appliance, aimed at the center of the appliance. The fuel depth is limited to 6 inches maximum. e� MESQUITE LOG CHARBROILER ONE AND ONE HALF (11/2) FLOW POINT NOZZLE [PM: 11983] A single Amerex Solid Fuel Appliance Nozzle (P/N: 11983) will protect a mesquite log charbroiler with a maximim cooking surface of 28'/2 inches wide (72.4 cm) by 24 inches deep (60.96 cm). The nozzle uses one and one half (1'h) flow points for this application and must be located between 19 and 44 inches (48.3 cm - 111.8 cm) above the cooking surface, anywhere along or within the perimeter of the appliance, aimed at the center of the appliance. Solid fuel is limited to three (3) layers of logs or 11 inch maximum stacked height. Solid Fuel - Charcoal FEB. 20, 1997 42" 16" 16" 48" Solid Fuel - Mesquite Chips & Chunks Solid Fuel - Mesquite Logs AR OCTOBER 18, 1999 CYLINDER REQUIREMENTS ACTUATION NETWORK LIMITATIONS: EXr4658) I2 1 3 11 4 1 5 1 6 1 7 1 11 1 9 1 10 , 1 - 11 112-22 123-331134-44 1 45 -SS 156-66 167-77 178-88 189-99 1 100 - 110 The Actuation Network for the Amerex KP Restaurant Fire Suppi installer supplied copper tubing or pipe that connects the Mechar valve. A single Mechanical Release Mechanism is capable of acts discharging a single 10 in nitrogen cylinder (P/N: 12856) througl, Note: If a Vent Plug (P/N: 10173) is used it must be placed in an accessible location anywhere in the actuation line to aid in releasing pressure after the system has discharged. See the RECHARGE Section VIII. LIMITATIONS (SINGLE OR MULTIPLE CYL. SYSTEMS): Copper Tubing - 1/4" O.D. Refrigeration Type with a minimum wa thickness of .049 inches. Use with brass or steel compressio style fittings (with brass or steel sleeves or ferrules). Maximum length (including all fittings) - 100 Feet (30.48 m) High Pressure Hose - 1/4" I.D. wire braid hose that is factory supplied. Maximum length (including all fittings) - 54 Feet (16.46 m) or a maximum number of P/N: 12854 Hose Assemblies is 40. Pipe - 1/a" NPT Schedule 40 made of stainless steel, gal- vanized, chrome plated or black iron pipe. Maximum length - 22.2 Feet (6.77 m) Maximum tees - 9 Maximum elbows - 9 (Note: 2 - 450 elbows = 1 - 900) Note: Different methods of constructing the actuation network may be mixed, provided that the shortest limitations are followed. Example: A mix of 1/" copper tubing and 1/4" high pressure hose requires that the hose limitations be followed (no more than 54 Feet (16.46 m) for the complete network. A mix of 1/4" high pressure hose and 1/4" pipe requires that the 5• pipe limitations be followed (no de� more than 22.2 Feet (6.77 m) No'�°`� for the complete network. N Q DISTRIBUTION PIPING NETWORK LIMITATIONS: sion System consists of factory supplied hose, ll Release Mechanism to each cylinder discharge ing up to 10 Agent Cylinder Discharge Valves by e actuation network. DoVent Plug (P/N: 10173) MECHANIC. QEI.EASE YC s location for rg (PM: 10173) MECHANICAL RELEASE YOOME Nitrogen. - Maximum Total Length for: Feet Meters %" Copper Tubing 100 30.48 Y." 10 Hose 54 16.46 1/4' Schedule 40 Pipe 22.2 6.77 i Section I-V : Design Page .{r :,%Fs Amerex KP -375 Wet' Chemical Systen (EX 4658) - GRIDDLE PROTECTION - LARGE TWO (2) FLOW POINT NOZZLE [P[N: 14178] The Amerex Range Nozzle (P/N: 14178) has two (2) flow Points and will protect a griddle surface of 48 inches wide (121.9 cm) x 30 inches deep (76.2 cm). The nozzle must be located along the perimeter of the appliance and within a verticle height range from 24" to 50" above the surface of the appliance. The aiming point for the nozzle is the "Point of intersection" of a straight line from the nozzle location to the center of the appliance, with an 11 inch square, generated about the center point of the griddle. 11" Square Centered on Griddle Perimeter of Griddle Note: Max. 8 min. heights must be measured from the tip Of the nate vertically to the surface of he appliance of Intersection %IM POINT Nozzle Location SEPT. 20, 1997 lax. hin. m B�nun 50" 24" i t'Square Centered L:j on Gdtltlle Cerner Nozzle may be located at any one of four corners 11" Square Centered on Griddle Can rr of Griddle Point of I AIM e7 24" 15" MInGriddleCenter Centered GRIDDLE PROTECTION - LOW PROXIMITY TWO (2) FLOW POINT NOZZLE [P/N: 14178] y ,f;— 24"max. 30' max. The Amerex Range Nozzle (P/N: 14178) has two (2) flow I ' v—: 15" min. points and will protect a griddle surface of 48 inches wide 1' ' (121.9 cm) x 30 inches deep (76.2 cm). The nozzle must xt be located at any one of the four corners of the appliance and within a verticle height range from 15" to 24" above the surface of the appliance. The aiming point for the 48" max. II'square nozzle is the "Point of intersection" of a straight line centered on from the nozzle location to the center of the appliance, Griddle Center with an 11 inch square, generated about the center point of the griddle. Note:Max. min. heights must be meas nom ed from the tip of the vertically to the surface of 11" Square Centered on Griddle Can rr of Griddle Point of I AIM e7 24" 15" MInGriddleCenter Centered .MAY 1, 1995 t.. acio ` vz.R n Paget= :9 65 8) The Amerex KP Restaurant Fird Suppression Systems Distributic i Piping Network consists of : Supply Lines, Duct Branch Lines, Plenum Branch Lines, and Appliance Branch lines. A Supply Line is the distribution piping Typical Single that runs from the Distributor outlet to the s Cylinder System beginning of the last branch line, including ` �, o�o� Layout all fittings. �pptt ` 4e�e �k A Duct Branch Line is the distribution piping that runs from the supply line to the duct nozzles, including all fittings kpv used to exit the supply line. elk A Plenum Branch Line is the distribution piping that runs from the supply line to the plenum nozzles including all fittings used to exit the supply line. �r NNOLZ kENA%eAL CA! YALVt VALVZ FR ` NbLt FR14 h024.t` %IkoL[ eAA Not Typical Single Cylinder System Layout alk °cc Typical Single Cylinder System Layout ho�ZLJ"'� SINO 8�k %.R,4� rIL 14 hoo� Section TV Design , P.agesTV--10 Amerx ISP -35 WetChemical System EX'4658) �^ Appliance Branch Line is the piping which runs from the supply line to any appliance nozzles including all fittings :sed to exit the supply line. clr� 4" 4j `\ klc� ket � MEQ �t f FR�t GENERAL REQUIREMENTS FOR DISTRIBUTION NE11WORK PIPING: MAY 11 1995 Typical Single Cylinder System Layout ko24.z \ SINC LF 8 ,h 4:1 wipe used for the distribution network must be schedule 40 (blac , chrome or stainless steel) WARNING: GALVANIZED PIPE IS NOT ALLO ED EQUIVALENT PIPING: Pioing limitations are expressed in both linear and equivalent length . ,near piping is the actual length of straight pipe used on either: the inain supply line or branch line. Eculvalent piping is the total of linear pipe used either on the main sipply line or the branch line plus the equivalent :ength of all fittings used on either the main supply or a branch line. All pipe fittings have a calculable pressure loss which is equated to he pressure loss through a specific length of straight pipe. This loss is the equivalent length of the fitting. See ch rt for equivalent lengths of fittings. 3/8 INCH 1 0.6 1 1.3 0.8 1 2.70.3 % INCH 0.8 1.5 1.1 3.5 0.4 EXAMPLES Main Supply Pipe f `tel 2.7 Equiv. '• Ft. Equiv. Ft. 1.3 Equiv. Ft. 1.3 Equiv. 2.7 Ft, Equiv. Ft. Branch Line Example 8;8 Equivalent Feet for Fittings Main 0.8 Equiv. Ft. 1.3 Equiv. 2.7 Ft. Equiv. Ft. uPPly Pipe ===e 1.3 Equiv. Ft, Branch Line Example 6_1 Equivalent Feet for Fittings Example of Equivalent Feet Calculations Note that this is not the only configuration possible. Duct Branch (7.5 Eq. Ft.) 3' Linear 1' Linear (vertical rise) 4' Linear 5' Linear 5' Linear 5' Linear 5' Linear 4' Linear 5' Linear 5' Linear 6' vertical Plenum Branch Rise (4 Eq. Ft.) 2' Linear 1' Linear 1' Linear Fryer Branch (8.8 Eq. Ft.) Supply Line I'm millim 30 Linear Feet 20 Linear Feet Between First and Last Branch 6' Vertical Rise 4.5 Equivalent Feet Griddle Branch (5.3 Eq. Ft.) Combined Branch Lines 30 Linear Feet 29.5 Equivalent Feet 11 Flow points 4' Linear 4' Linear Char -Broiler Branch s• 9 oCD Ln BLANK PAGE RESERVED FOR FUTURE USE MAY 1, 1995 A RJB I L 15, 1996 K 6 b DISTRIBUTION PIPING LIMITS FOR SINGLE CYLINDER SYSTEMS USING ALL 3/8" PIPE When designing a KP375 system to protect a kitchen containing 4 Fryer, Wok or Range, the following MINIMUM PIPING must be met between the Distributor and the first nozzle rotecting the corresponding appliance. Minimum otal Minimum Flow Points Appliance Minimum Linear Ft Equivaler t Ft. Per System Fryer 6.5 10 2 Wok 9 1 22.111 6 Range 7 1 16.411 4 SUPPLY LINE LIMITATIONS - (NON-MANIFOLDED SYSTEMS h.75 GAL. SIZE) Pipe Diameter 318 in. Maximum Flow Points 11 Maximum Linear Feet 30 Maximum Equivalent Feet for Fittin s 20 Maximum Vertical Rise 6 Linear Feet Maximum Distance Between First Branch and Last Branch 20 Linear Feet BRANCH LINE LIMITATIONS: The total of all Branch Lines (Duct, Plenum, Appliance and Upright Broiler) cannot exceed 30 linear feet and 40 equivalent feet for fittings. The Branch Line can c ly contain identical nozzles (i.e.. a fryer branch must have only fryer nozzles [PIN: 13729] on it). DUCT BRANCH LINE LIMITATIONS: Pipe Diameter 318 in. Maximum Flow Points 4 Maximum Linear Feet 4 Maximum Equivalent Feet for Fittin gs 11 Maximum Vertical Rise 1 Foot PLENUM BRANCH LINE LIMITATIONS: Pipe Diameter 318 in. Maximum Flow Points 1 Maximum Linear Feet 4 Maximum Equivalent Feet for Fittir i gs 9 Maximum Vertical Rise 1 Foot APRIL 15, 1996 APPLIANCE BRANCH LINE LIMITATIONS (EXCEPT UPRIGHT BROILERS): Pipe Diameter 318 In. Maximum Flow Points 4 Maximum Number of Nozzles 2 Maximum Linear Feet 8 Maximum Equivalent Feelfor Fittings 9 Maximum Vertical Rise 0 Feet UPRIGHT BROILER BRANCH LINE LIMITATIONS: Pipe Diameter 318 in. Maximum Flow Points 1 Maximum Linear Feet 10 Maximum Equivalent Feet for Fittings 13 Maximum Vertical Rise 0 Feet Note: 1/2 flow point nozzles must be used as a pair on the same branch line. A maximum of 4 - 1/2 flow point nozzles per agent cylinder may be used. �l1NE 21, 1996 F,5-c,(.I on' II" Design Pag� t!V-1 4A • =Ar rex.KP-3751Wet Chemical System (EX4658) � SINGLE CYLINDER AND TWIN CYLIND< R MANIFOLDED SYSTEMS UTILIZING 1/2" SUPPLY, LINE PIPE SYSTEM DESCRIPTION: The Amerex KP -375 Wet Chemical System is sohcifically designed and Listed with the Underwriters Laboratory for the suppression of fires oc urring in commercial kitchen cooking appliances, plenum, hoods & ducts. All properly installd systems will operate automatically and manually. The Amerex KP -375 Wet Chemical System usel a liquid chemical designed to suppress fires using a process involving: 1)The saponification ollsurface grease, 2)The cooling effects of water vaporization, 3) The inerting effects of resultant team formation and 4) the interruption of the chemical chain reaction of combustion. There are two basic systems: 1) A single cylind r system and 2) a twin manifolded cylin- der system. From these basic systems it is possible tolpreate systems using combinations of the two basic systems. Such as, a three cylinder systemere two cylinders are manifolded to- gether & the third is installed as a single cylinder. Manifolding two cylinders together is advantage ius for it allows the installer up to twice as many flow points on a single distribution network. The nstaller is permitted to manifold the dis- charge of two cylinders, yielding as many as 22 flow p ints, which may be used in a single distri- bution system. The result is a reduction in the amount f piping required to install the 22 flow points. The type of system required for a particular inst Ilation will be determined through the guidelines covered in the "Design Section" of the man I. The following portion of the "Design Section" de lis with the distribution network limits which must be used in creating a single cylinder or twi cylinder manifolded system. These particular piping networks use 1/2" pipe as the supply ne, which runs from the distributor block to the first tee. The piping from the first tee to the begi ining of the last nozzle branch is called the supply branch and is 1/2" or 3/8" depending on the sy em requirements. The limitations placed on these distribution sys ms are broken into two categories: 1) Single Cylinder System, 2) Twin Cylinder Manifolded Pystem. Limitations for both categories are detailed in the following pages, information foundse where has no influence on the limits of these systems. - Sn—tiI F, Design Page IV -146'j I APRIL 15, 1996 IAmere:. K -3 5 Wet Chemical System :(EX4658)', DISTRIBUTION PIPING LIMITS for SINGLE CYLINDE9 SYS�MS USING 1/2" SUPPLY LINE When designing a KP375 system to protect a kitchen contain! g a Fryer, Wok or Range, the following MINI- MUM PIPING must be met between the Distributor and the first nozzl protecting the corresponding appliance. PIPING REQUIREMENTS Minimutn Total Minimum Flow Points Appliance Minimum Linear FL Equivalent FL Per System Fryer 6.5 10 2 Wok 9 22.1 6 I Range 1 7 1 16.4 11 4 1 SUPPLY LINE LIMITATIONS All pipe and fittings running from the distributor block to the Pipe Diameter Maximum Linear Fast Maximum Equivalent Feet Maximum Vertical Rise Above the SUPPLY BRANCH LINE LIMITATIONS: All pipe and fittings leaving the first tee in the system and branch tee. 15" 20 30 10 Feet with the first fitting in the last nozzle branch line. Pipe Diameter I �I or 3/8' Maximum Equivalent Feet 1 25' ' The maximum equivalent feet In the supply NOZZLE BRANCH LINE LIMITATIONS: All pipe and fittings leading from the supply branch to a Pipe Diameter Maximum Equivalent Feet per Branch Maximum Vertical Rise Above the Supply Max. Equiv. Feet of all Nozzle Branches - line in a split piping system is 35. nozzle. 'A" or 3/6 In. 16 4 FL 65 Duct branch using two duct nozzles may use max. of 20 equivalent feet. " Duct Branch only. GENERAL SYSTEM LIMITATIONS: A maximum of 11 flow points is permitted with each 2. Nozzle types may not be mixed 6n any nozzle brant nozzle branch. 3. The Total linear feet of pipe for supply branch plus n 4. The distributor and the distribution hose are not to b 5. A maximum of 4 Duct nozzles are permitted per sin 6. No mixing of pipe sizes is allowed within Branch cat to be 3/8" pipe, then all must be 3/8" pipe. You are n, some 3/8" braches. line and a maximum of 4 flow points per czle branches may not exceed 30 feet. included in any calculations. e cylinder system. Tories. Example: If one nozzle branch is permitted to mix some t/2" branches and ., �. . � � .� cr x ,`kPRIL 15 1996 164,a A`me;re 37 eft C 'e ba ste �EX4 58�" TYPICAL DISTRIBUTION NETWORK FOR SINGLE CYLINDER SYSTEM USINGI/2" SUPPLY LINE 4 FOOT MAX. 1/2' 10 FOOT MAX. l DUCT PLENUM FRYER NOZZLES DISTRIBUTOR IDDLE I RANGE STRAIGHT PIPING SYSTEM DUCT 4 FOOT MAX. � :C U 10 FOOT MAX. 'SUPPLY LINE SUPPLY WOK PLENUM DISTRIBUTOR r RANGE SPLIT PIPING SYSTEM NOZZLE BRANCH FRYER GRIDDLE (OVERHEAD) NOTE: The schematics above do not represent the only configurations possibilities. They are supplied for reference only. Srrnna �U�' De ' hi1V�i1„her�tMa t ' E' 6 a JUNE 21, 1996 DISTRIBUTION PIPING LIMITS for IN CYLINDER MANIFOLDED SYSTEM USING 1/2" SUPPLY LI E When designing a KP375 system to protect a kitchen containin a Fryer, Wok or Range, the following MINI- MUM PIPING must be met between the distributor and the first nozzle otecting the corresponding appliance. SUPPLY LINE LIMITATIONS All pipe and fittings running from the distributor block to the first Pipe Diameter Maximum Equivalent Feet Maximum Linear Feet Maximum Vertical Rise above the Distributor Centedine to Centerline Distance between Cyt. SUPPLY BRANCH LINE LIMITATIONS: All pipe and fittings leaving the first tee in the system and ending with tee. % in 30 12 6 feet 4 feet first fltfing in the last nozzle branch tine. Piping configuration Straight Split Appliance PIPING REQUIREMENTS Minimum Total Minimum Linear Ft Equivalent Ft Minimum Flow Points Per System Fryer 6.5 10 2 Wok 9 22.1 6 Range 7 18.4 4 SUPPLY LINE LIMITATIONS All pipe and fittings running from the distributor block to the first Pipe Diameter Maximum Equivalent Feet Maximum Linear Feet Maximum Vertical Rise above the Distributor Centedine to Centerline Distance between Cyt. SUPPLY BRANCH LINE LIMITATIONS: All pipe and fittings leaving the first tee in the system and ending with tee. % in 30 12 6 feet 4 feet first fltfing in the last nozzle branch tine. Piping configuration Straight Split Pipe Diameter ''A in. Maximum Equivalent Feet 30 35 Maximum Linear Feet of Pipe 15 20 ' A maximum of 10 linear feet of pipe in either branch beyond the 1 A minimum of 5 flow points must be provided in a supply branch. NOZZLE BRANCH LINE LIMITATIONS: All pipe and fittings leading from the supply branch to a system Pipe Diameter Maximum Equivalent Feet per Branch Maximum Linear Feet per Branch vertical Rise above supply Branch - Dud Only Max. Equiv. Feet of all Nozzle Branches - Total GENERAL SYSTEM LIMITATIONS: 1. A maximum of 22 flow points is permitted in accordance with Table 14E 2. Nozzle types may not be mixed on any nozzle branch line and a maxim 3. The Total linear feet of pipe for supply branches and nozzle branches may 4. The distributor and the distribution hose are not to be included in any c 5. A maximum of 8 Duct nozzles per twin cylinder manifolded system. tee. 3/8- 25 7 4 feet 100 of 4 flow points per nozzle branch. exceed: 32' Straight / 38' Split system. r�� . , �,a,`.., �_