INTERIOR DEMOLITION
& BEAM REPAIR
2014 APPLICABLE CODES
2010 FLORIDA BUILDING CODE(S)
2010 FLORIDA BUILDING CODE EXISTING BUILDINGS
ALTERATION- LEVEL 2
2010 FLORIDA FIRE PREVENTION CODE
2008 NATIONAL ELECTRIC CODE
2009 NFPA I AND NFPA 101 FLORIDA EDITION
FLORIDA STATUTES
FLORIDA ADMINISTRATIVE CODE
LOCAL CITY ORDINANCES
2014 WIND DESIGN CRITERIA
FBC 2010 REFERENCING ASCE 7-10
V
139 MPH
RISK CATEGORY
IC
GCPl
+/-0.18
EXPOSURE
B
P+
30 PSF
P-
40 PSF
�V a
ms fl q
307 E 2ND STREET
5A—NF—Of") BU�I D�NG``�_
SANFORD, FLORIDA, 32771
ApERMITISSUEDSHALLaeA
jjV4 THE 6ECGNSTFIKAND OTA
RORSETS
"LAI
FOR ROB WALLACE
LIC�THOR�YflUVOE,CANCEL-A�
P RMIT PREVENT
lL
(3 21) 362 815 3
IAL FROM THEREAFIEF<
COJOEDES. NOR SHALL SSUA
FFJOM
THE BUILDING OFFICS I
A I RTH S CODE
R GUIRIN(3
CONSTRIONOR VIOLATIONS
PARCEL ID: 25-19-30-5AG-0401-0040
SCOPE OF THE WORK:
REMOVE INTERIOR INTERIOR FINISHES AND CONSTRUCTION BELOW THE
EXISTING CEILING AND INSIDE OF THE EXTERIOR WALLS
REPAIR THE SOUTH END OF THE ROOF/CEILING STRUCTURE BEARING BEAM
LEGAL DESCRIPTION: LOT 4 & E 2 FT OF LOT 5 - BLK 4 TR I - TOWN OF
SANFORD - PB I P 58
INDEX TO DRAWINGS
COVER & DATA PERN11T # �r s7 fl
2 DEMOLITION PLAN J -9--*fA
3 EXISTING CEILING DETAILS 7b 0A
4 BEAM REPAIR PLAN / SECTION
5 BEAM REPAIR DETAILS - 1
6 BEAM REPAIR DETAILS - 2
WCE
(l ANDREW KUTZ
ARCHITECT
AR0006491
(407) 415-6554
AKUTZQCFL.RR.COM
I DEC 2014
THESE 2 RAFTERS 3
HAVE BEEN PREVIOUSLY
REMOVED AND ARE TO 6
BE REINSTALLED
60'-1" DEMOLITION NOTES:
THESE DRAWING REPRESENT AN AS—BUILT CONDITION AND
II INCLUDE DIRECTIONS AND SPECIFICATIONS FOR FURTHER ACTIONS
11 TO OBTAIN A BUILDING PERMIT AND PERFORM THE REQUISITE
it N II �i �i WORK.
I I
Ia II NO FURTHER DEMOLITION OR REMOVAL OF MATERIALS IS TO
IY DETERIORATED BEAM END 11 — PROCEED UNTIL THE DETERIORATED CENTER BEAM END IS
I� IS TO BE SHORED BEFORE II 'D PROPERLY SHORED.
16 REPAIRS ARE UNDERTAKEN II
1u
lu It i I REPAIR DRAWINGS SHOW CONSTRUCTION DETAILS FOR FINAL
EXISTING STRUCTURAL IL ---------- j— �= CONSTRUCTION. THE CONTRACTOR IS RESPONSIBILE FOR MEANS
jp AND DECORATIVE BEAM-- r II AND METHODS OF CONSTRUCTION. CONTRACTOR SHOULD CONSULT
AND STRUCTURAL COLUMNS �� II A REGISTERED ENGINEER FOR THE DESIGN OF SHORING AND
ARE TO REMAIN ��— ij BRACING ADEQUATE FOR ALL THE LOADS WHICH THE INCOMPLETE
—T— --�j i II STAGES OF CONSTRUCTION IS REQUIRED TO RESIST.
1 II -- --� — -- _,�—_.! CONTRACTOR SHALL REMOVE ALL DEMOLITION AND
--° — —----+---—_--- ---- _ F --_ _--==------=
-- ----- =--r ---- _----- Y -I
QII � CONSTRUCTION DEBRIS FROM THE SITE. NOTE THAT THE CITY OF
,u= Pit
SANFORD SPECIFIES THE ONLY ACCEPTABLE SOURCE FOR
=-� F J 2 11 II DUMPSTERS.
II rr�
OUI L -i 3 �
�j II I I I I DEMOLITION SHALL INCLUDE THE COMPLETE DEMOLITION AND
J II INDICATES REMOVE It I I I I REMOVAL OF ALL NON BRARING INTERIOR FINISHES INCLUDING
II �i F WALLS AND DOORS EXCEPT —
it II I I i I DECORATIVE METAL CEILING AND DECORATIVE CENTER BEAM
SHALL REMAIN IN PLACE
�j II LJ LJ ALL STRUCTURE , INCLUDING COLUMNS, BEAMS JOISTS AND
II II ROOF FRAMING ARE TO REMAIN IN PLACE
iiEXISTING DOORS ARE TO BE SAVED FOR POTENTIAL REUSE
1 jl 11 ALL EXPOSED ELECTRICAL DEVICES INCLUDING LIGHT FIXTIRES
II I I AND CONDUIT ARE TO BE REMOVED EXCEPT —
� — — — — EXISTING ELECTRICAL PANELS ARE TO REMAIN IN PLACE
i
\`---EXISTING W BRICK WALLS EXISTING CANOPY ABOVE---/ ALL AIR—CONDITIONING DUCTWORK IS TO BE REMOVED
AIR HANDLING CONDENSOR AND COMPRESSOR ARE TO BE SAVED
FOR POTENTIAL REUSE
INTERIOR PLUMBING AND PLUMBING FIXTURES ARE TO BE
REMOVED AND PLUMBING IS TO BE CAPPED FOR FUTURE USE
EXCEPT
THE EXISTING VENT WASTE STACK THROUGH THE ROOF IS TO
DEMOLITION PLAN REMAIN IN PLACE
WALL MOUNTED HOSE BIB MAY REMAIN
SCALE" 1/8" = 1'-0"
V ANDREW KUTZ
ARCHITECT
2AR0006491
(407) 415-6554
AKUTZQCFL.RR.COM
I DEC 2014
BEAM END IS DETERIORATED
AND PARTIALLY MISSING
EXISTI
BEAM POCK
IN BRICK W
EXISTIN(
EXTER
BRICK W,
ROOFING
;OOF DECK
(10 RAFTERS
)OUBLE 2x4 PLATE
'ERTICAL 2X4 @24`OC
;TRUCTURAL BLOCKING
3x12 BEAM
2X10 CEILING JOISTS
2X4 LEDGER
COVE FRAMING —7
N
•� i
� N
SLOPING ROOF
O O
DETAILS OF EXISTING CONSTRUCTION
9@
I
W
to fy-
_Q
METAL CEILING PANELS:
-2X4 @ 24" OC
DECORATIVE METAL COVE
8x8 COLUMN BEYOND
eA ANDREW KUTZ
ARCHITECT
3AR0006491
(407) 415-6554
AKUTZOCFL.RR.COM
I DEC 2014
CONFIRM 'IFIAT THE NEW C 12x10.6 5/8" THRU BOLTS
BEAM POCKET BEAM WOOD IS NOT EACH SIDE WITH 2x2 BEARING
NOTE:POCKET AREA OF OBSERVED BEAM DETERIORIZATION^DETERIORATED FROM PLATE BOTH ENDS
MUST GE THIS POINT ON - ADVISE
ENLARGUD THE ARCHITECT / ENGINEER
SLIGHTLY OF ANY FURTHER DAMAGE
TOINSTALL
REPAIR
MATERIALS
TES TT ° II I I I/2" STEEL PLATE
Ne �� II , II / TOP AND BOTTOM —EXISTING
8 X 12 WOOD BEAM
5 5 XO
5 5 5 LEDGER TO
REMAIN
4 5'-0"6" 4'-0" 6"
10'-4"
FLASH AND REPAIR REPLACE MISSING, O PLAN VIEW
BASE FLASHING & DETERIORATED 5/8* BOLTS 5/8"THRU BOLTS
ROOFING TO SECURE OR OUT OF PLACE @ 12' OC WITH 2X2 BEARING
WATERTIGHT 2X4 BLOCKING PLATE EACH SIDE
SCUPPER SLOPE
I`
C8xll.5 ® RICHARDSON ANDREW KUTZ
WITH EPDXY SET ®ENGINEERING ARCHITECT
1/2X6 BOLTS RICHARD B RICHARDSON PE AR0006491
24" OC BEAM REPAIR 131 ZELMA STREET
'=h
BEAM TO FLR ORLANDO, FLORIDA 32801 UTZ 415-65.0
1 31I1� (407) 425-4002 AKUTZ�CFL.RR.COM
oily LIC# 00012380 ID#EB26251 I DEC 2014
2x10 RAFTERS
24' OC
2x4 BLOCKING
A34 TYPICAL
I /
-'@ 24' OC
..
I I NEW C12xI0.6
EACH SIDE
II-
xIO CEIL JOTS
\ Qo ❑° I ❑° Qo °
/
@24OC
i
F'
WELDED 1/2"X2 1/2" U210 TYPICAL
DECORATIVE
o
STUD -TYPICAL 24' OC
COVE
U)
3REOVE
I
6DETER
ORATED OI ELEVATION / SECTION
2 WOOD
6
I`
C8xll.5 ® RICHARDSON ANDREW KUTZ
WITH EPDXY SET ®ENGINEERING ARCHITECT
1/2X6 BOLTS RICHARD B RICHARDSON PE AR0006491
24" OC BEAM REPAIR 131 ZELMA STREET
'=h
BEAM TO FLR ORLANDO, FLORIDA 32801 UTZ 415-65.0
1 31I1� (407) 425-4002 AKUTZ�CFL.RR.COM
oily LIC# 00012380 ID#EB26251 I DEC 2014
-8" TYPICAL
5/8" THRU BOLT
@ 24" OC - -
VOID AREA
WHERE
DETERIORATED
WOOD
REMOVED
�61
8X12
WOOD
BEAM
THN BOLT
OC \
C
II' TYPICAL
EVERY 2X4 NOTE: SHORE RAFTERS
AND SHORE CEILING
JOISTS BEFORE
I/2x2 1/2 STUD BEGINNING REPAIRS
@ 24" OC - WELD
TO 1/2" STEEL PLATE
-SNUG THESE BOLTS BUT
DO NOT OVERTIGHTEN
2X2 BEARING
PLATE EA END
EXISTING
2X10
CEIL JOIST
@ 24" OC
2 x 12 CUT TO FIT- TYPICAL
U210 TYPICAL -
EVERY 2x4
X41/2x2 1/2 STUD
@ 24" OC - WELD
TO 1/2" STEEL PLATE
5'-10" X 1/2'x II" STEEL PLATE
WITH 5/8" BOLTS 12' OC
TOP AND BOTTOM
TRIM EXISTING_
JOIST ENDS TO FIT
1/2x2 1/2 STUD
/
@ 24' OC - WELD
EXISTING
2 X 10
CEIL JOIST
@ 24" OC
TO 1/2" STEEL PLATE
REPLACE
,{
3111 �I
RICHARD B RICHARDSON PE
131 ZELMA STREET
ORLANDO, FLORIDA 32801
(407) 425-4002
2X4 BLOCKING
j
5'-10" X 1/2'x 11"
DETERIORATED
STEEL PLATE
I DEC 2014
"
-WITH 5/8' BOLTS
/
12" OC TOP AND
REMOVED
U210 TYPICAL
BOTTOM
EVERY 2x4
X41/2x2 1/2 STUD
@ 24" OC - WELD
TO 1/2" STEEL PLATE
5'-10" X 1/2'x II" STEEL PLATE
WITH 5/8" BOLTS 12' OC
TOP AND BOTTOM
I,
G
A34 TOP AND E 1
BOTTOM EVERY
2X4
SHIM ANY GAPS 8 X 12
-BETWEEM BEAM WOOD
AND TOP AND BEAM
BOTTOM PLATES
5X24'
BOLT
i C
2x12 CUT
TO FIT
TYPICAL
2X2 BEARING
PLATE EA END
C12xI0.6 EACH
SIDE CONTINUOUS
\ 2x4 NAILED
TO WOOD BEAM
nB
BEAM REPAIR DETAILS
0
6" X 1/2"x 11" STEEL
WITH 2-5/8" BOLTS
EACH SIDE TOP
AND BOTTOM
SHIM ANY GAPS
BETWEEM BEAM
AND TOP AND
BOTTOM PLATES
110110 RICHARDSON
ANDREW KUTZ
5/8" THRU BOLT
@ 24" OC
--------
- - - - - - - - - -
/
RENGINEERING
EXISTING
2 X 10
CEIL JOIST
@ 24" OC
VOID AREA
,{
3111 �I
RICHARD B RICHARDSON PE
131 ZELMA STREET
ORLANDO, FLORIDA 32801
(407) 425-4002
WHERE
j
DETERIORATED
I DEC 2014
WOOD
/
REMOVED
U210 TYPICAL
I,
G
A34 TOP AND E 1
BOTTOM EVERY
2X4
SHIM ANY GAPS 8 X 12
-BETWEEM BEAM WOOD
AND TOP AND BEAM
BOTTOM PLATES
5X24'
BOLT
i C
2x12 CUT
TO FIT
TYPICAL
2X2 BEARING
PLATE EA END
C12xI0.6 EACH
SIDE CONTINUOUS
\ 2x4 NAILED
TO WOOD BEAM
nB
BEAM REPAIR DETAILS
0
6" X 1/2"x 11" STEEL
WITH 2-5/8" BOLTS
EACH SIDE TOP
AND BOTTOM
SHIM ANY GAPS
BETWEEM BEAM
AND TOP AND
BOTTOM PLATES
110110 RICHARDSON
ANDREW KUTZ
RENGINEERING
ARCHITECT
,{
3111 �I
RICHARD B RICHARDSON PE
131 ZELMA STREET
ORLANDO, FLORIDA 32801
(407) 425-4002
AR0006491
(407) 415-6554
AKUTZ�CFL.RR.COM
LIC# 00012380 ID#EB26251
I DEC 2014
INCREASE BEAM POCKET
SIZE AS REQUIRED TO
RECEIVE NEW REPAIR
MATERIALS
5/8' MACHINE BOLTS
4' X 1/2' x 1 1/2 TOP
RICHARDSON
PLATE WELDED CONTIN
o I-
TO TOP OF C8xII.5
~ it p
II/16 HOLES IN ENDS OF
PLATE TO SECURE TO
RICHARD B RICHARDSON PE
BEAM ABOVE
0
2-II/16" HOLES EACH
END OF 1/2' STEEL
TOP PLATE TO SECURE
WALL CHANNEL TO
BEAM ABOVE
C8xII.5
WITH EPDXY SET
1/2x6 BOLTS
24" OC FLOOR
TO BEAM
_Cl2XI0.6 FLANGE
ABOVE
BRICK WALL
NEW CEILING JOIST
2X10 SYP #1
SISTER TO EXISTING
JOIST TAIL AT WALL
U210 TO BEAM REPAIR
MIN 5 - 1/4"x3" WOOD
SCREWS NEW 2X10 TO
I EXISTING 2X10 TAIL
MISSING 2x10
CEILING JOIST
2X2 DEADWOOD I EXISTING 2X10
CEILING JOIST
NEW 2X6 PT WITH \—CEILING LINE
1/2x6 EPDXY SET
ANCHOR 48" OC
REPLACE JOISTS ( J)
NOTES
STEEL SHALL BE 36 KSI YIELD
BOLTS SHALL BE A307
THE STRUCTURAL DESIGN IS BASED ON AN ENCLOSED STRUCTURE.
DESIGN LOADS IN ACCORDANCE WITH FBC ARE:
ROOF LOADS 20 PSF
WIND LOADS 139 MPH (PER ASCE 7)
INTERIOR PARTITIONS 5 PSF PERPENDICULAR
TO THE FACE OF THE WALL
LUMBER GRADES SHALL BE A MINIMUM OF
HEADERS, COLUMNS, BEAMS 8. OVERBUILD
FRAMING #2 SYP FB=1500 PSI
WALLS, BLOCKING AND MISCELLANEOUS #2 SPF
SILL PLATES #2 SYP PT
PT LUMBER SHALL ALSO BE UTILIZED
WHEREVER INDICATED ON THE DRAWINGS
ALL NAILS SHALL BE COMMON WIRE NAILS UNLESS INDICATED
OTHERWISE
CONTRACTOR IS TO CHECK ALL DIMENSIONS AGAINST EXISTING
CONDITIONS BEFORE FABRICATING ANY STEEL COMPONENTS
THESE STRUCTURAL REQUIREMENTS SHALL EXTEND TO ALL ITEMS
COVERED SSTD 10-93, EXCLUDING FINISHES AND NON-STRUCTURAL
ITEMS, MISC PARTS, OVERHEAD DOORS, ROOFING AND WALL
WATERPROOFING, WHICH ARE TO BE DESIGNED BY OTHERS
RICHARDSON
ANDREW KUTZ
NENGINEERING
ARCHITECT
RICHARD B RICHARDSON PE
AR0006491
131 ZELMA STREET
(407) 415-6554
FLORIDA 32801
ORLAN07)
AKUTZQCFL.RR.COM
11
425-4002
LIC# 00012380 ID#EB26251
I DEC 2014