HomeMy WebLinkAbout406 W 15 St 17-333 Remodel plans0 N N u 0 Ir w O U I U IN 101, , A -u 'I k - a loymAl I OIL &Z 16-IM091-11ml 11 406 15TH ST, SANFORD, FLORIDA 32771 GENERAL: 1. OWNER/BUILDER/CONTRACTOR TO VERIFY ALL DETAILS AND DIMENSIONS PRIOR TO CONSTRUCTION.\ 2. PROVIDE (1) NO. 5 ELECTRICAL GROUND TO FOUNDATION STEEL. 3. ALL WORK SHALL CONFORM TO 2007 FLORIDA BUILDING CODE WITH 2009 SUPPLEMENTS AND ALL APPLICABLE LOCAL ORDINANCES. 4. OWNER/BUILDER/CONTRACTOR SHALL COORDINATE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ANCHORS, EMBEDS AND SUPPORTS OR ANY OTHER ITEMS WHICH AFFECT THE STRUCTURAL DRAWINGS. SITE PREPARATION: 1. ALL ORGANIC AND REFUSE MATERIALS AND/OR SOFT AREAS SHALL BE REMOVED AND SOIL PREPARED TO AN ALLOWABLE BEARING PRESSURE OF 2000 PSF. 2. ANY CONDITIONS WHICH COULD PREVENT THE ATTAINMENT OF 2000 PSF SHALL BE NOTED TO THE ARCHITECT AND/OR ENGINEER IMMEDIATELY. SLABS ON GRADE: 1. ALL FLOOR SLABS SHALL BE PLACED UPON A 4" THICK SAND LAYER FOR FINE GRADING. 2. 0.006 MIL POLY VAPOR BARRIER SHALL BE PLACED OVER BORA-CARE TERMITE PROTECTION. FILL PRIOR TO FOOTING OR SLAB POURS. CONCRETE AND .REINFORCING: 1. ALL CONCRETE WORK SHALL CONFORM TO ACI STANDARD BUILDING CODES FOR REINFORCED CONCRETE (ACI 318-02). 2. ALL CONCRETE SHALL HAVE A MINIMUM Fc --3000 PSI AT 28 DAYS, INCLUDING SLABS, FILLED CELLS AND LINTELS. 3. FOUNDATION DESIGN IS BASED ON A MINIMUM SOIL BEARING CAPACITY OF 2000 PSF. 4. REBAR SHALL CONFORM TO ASTM A-615 GRADE 60, AND 25" MINIMUM LAP AT ALL JOINTS, SLABS WITH FIBER MESH OR WELDED FIRE FABRIC SHALL CONFORM TO ASTM A-185. 5. VERTICAL REBAR WALL REINFORCING SHALL BE STANDARD HOOK WITH A PROJECTION OF 25" MINIMUM ABOVE SLAB AND A 7" MINIMUM EMBEDMENT. 6. ALL STANDARD REINFORCING STEEL 90 HOOKS SHALL EXTEND AT LEAST (12)BAR DIAMETERS BEYOND THE BEND. 7. ALL VERTICAL REINFORCEMENT SHALL TIE INTO FOUNDATION STEEL BY MEANS OF (1) NO. 5 REBAR WITH STANDARD HOOK AND TOE INTO CONTINUOUS BOND BY MEANS OF (1) STANDARD HOOK (25" LAP MINIMUM). 8. CONVERAGE FOR REINFORCEMENTS SHALL BE AS FOLLOWS: FOOTING 3" MIN, SLABS ON GRADE 1-1/2" FROM TOP, LINTELS AND BOND BEAMS 1-1/2" FROM TOP (ON STIRRUPS) MASONRY: 1. MASONRY CONSTRUCTION SHALL CONFORM TO ACI STANDARD BUILDING CODES FOR CONCRETE STRUCTURES (ACI 531-99). 2. CONCRETE BLOCKS SHALL CONFORM TO ASTM C 90 28 DAY STRENGTH EQUAL TO 2000 PSI, FM=1500 PSI LAID IN RUNNING BOND. 3. ANY LENGTHS OF WALL THAT ARE NO LESS THAN HALF THE PLATE HEIGHT AND NOT CONTAINING OPENINGS GREATER THAN 144 SQUARE INCHES TOTAL, WITH CONT. BOND BEAM SHALL BE CONSIDERED TO BE SHEAR WALL SEGMENTS. 4. MORTAR SHALL BE TYPE "S" OR "M". 5. WHERE SHOWN, VERTICAL CELLS SHALL BE POURED SOLID WITH GROUT AT MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS, GROUT SLUMPS NOT LESS THAN 8" AND REINFORCED WITH MINIMUM NO. 5 REBAR AND 25" MINIMUM OVERLAP. 6. GROUT FOR FILLED CELLS SHALL BE POURED OR PUMPED IN LIFTS NOT TO EXCEED TEN (10) FEET IN HEIGHT, AND SHALL BE CONSOLIDATED AT TIME OF POURING BY RODDING OR VIBRATING. 7. PROVIDE KNOCKOUT IN CMU AT BASE OF EACH FILLED CELL FOR VISUAL VERIFICATION OF COMPLETE GROUT PENETRATION. STRUCTURAL LUMBER: 1. SEE TRUSS TABLE FOR ANCHORAGE. 2. GRAVITY LOADS WHERE TAKEN INTO ACCOUNT DURING THE PROCESS OF THIS STRUCTURE. 3. ALL STRUCTURAL AND LOAD BEARING LUMBER SHALL HAVE A MINIMUM Fb=1200 PSI. 4. ANY WALLS GREATER THAN 9 FEET HIGH SHALL HAVE NO LESS THAN ONE INTERMEDIATE BRIDGING SPACED NO MORE THAN 72" APART. 5. ALL LOAD BEARING WALLS SHALL HAVE DOUBLE SYP# TOP PLATES. SOUL PLATES ON MASONRY SHALL BE SALT SOLUTION PRESSURE TREATED. STRUCTURAL STEEL: 1. STEEL WORK SHALL CONFORM TO THE AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS LATEST EDITION. 2. STRUCTURAL STEEL SHALL CONFORM TO ASTM -36. TIT.Cf'T . A TMF.R PLANS, NOTES, SPECIFICATIONS, DETAILS AND ALL OTHER INFORMATION DEPICTED ON THIS SHEET AND ALL ATTACHED SHEETS HAS BEEN PREPARED TO MEET FBC STANDARDS LATEST EDITION. IT IS THE RESPONSIBILITY OF THE OWNER/BUILDER/CONTRACTOR TO VERIFY LOCAL, COUNTY AND STATE CODE ENFORCEMENT AGENCIES, COMPLIANCE WITH BUILDING CODES AND ORDINANCES FOR CONSTRUCTION. ANY CHANGES MADE TO THE PLANS AFTER APPROVAL BY GOVERNING AREA MUST BE DONE SO WITH THE CONSENT OF THE ENGINEER. ANY CHANGES MADE WITHOUT CONSENT WILL FORFEIT THE ENGINEER FROM ANY LEGAL CONTINGENCIES WHICH MAY RESULT FROM CHANGES. SHEET INDEX CS COVER SHEET WINDOW DOOR ZONE EFFECTIVE WIND AREA BASIC WIND SPEED Vult STAIR DETAILS El ELECTRICAL PLAN M1 (ft') 140 MPH PLUMBING PLAN CONSTRUCTION OR VIOLATIONS OF THIS CODE A 4 4 10.0 35.3 -38.2 B 4 4 20.0 33.7 -36.7 C 4 4 50.0 31.6 -34.6 D 4 4 100.0 30.0 -33.0 E 4 4 500.0 26.3 -29.3 F 5 5 10.0 35.3 -47.2 �z C 5 5 20.0 33.7 -44.0 �-� H 5 5 50.0 31.6 -39.8 -Ti 1 5 5 100.0 30.0 -36.7 J 5 5 500.0 26.3 -29.3 TIT.Cf'T . A TMF.R PLANS, NOTES, SPECIFICATIONS, DETAILS AND ALL OTHER INFORMATION DEPICTED ON THIS SHEET AND ALL ATTACHED SHEETS HAS BEEN PREPARED TO MEET FBC STANDARDS LATEST EDITION. IT IS THE RESPONSIBILITY OF THE OWNER/BUILDER/CONTRACTOR TO VERIFY LOCAL, COUNTY AND STATE CODE ENFORCEMENT AGENCIES, COMPLIANCE WITH BUILDING CODES AND ORDINANCES FOR CONSTRUCTION. ANY CHANGES MADE TO THE PLANS AFTER APPROVAL BY GOVERNING AREA MUST BE DONE SO WITH THE CONSENT OF THE ENGINEER. ANY CHANGES MADE WITHOUT CONSENT WILL FORFEIT THE ENGINEER FROM ANY LEGAL CONTINGENCIES WHICH MAY RESULT FROM CHANGES. SHEET INDEX CS COVER SHEET Al EXISTING CONDITIONS A2 FLOOR PLAN A3 STAIR DETAILS El ELECTRICAL PLAN M1 MECHANICAL PLAN P1 PLUMBING PLAN SCOPE OF WORK: REMODEL EXISTING STRUCTURE. TYPICAL CONSTRUCITON NOTES INTERIOR GENERAL NOTES: 1. DOMESTIC CLOTHES DRYER DUCTS SHALL HAVE A SMOOTH INTERIOR FINISH WITH JOINTS RUNNING THE DIRECTION OF THE AIRFLOW. THE MAXIMUM LENGTH SHALL NOT EXCEED 25 FEET (7620 MM) FROM THE DRYER LOCATION TO THE DISCHARGE TERMINAL. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 30" (762 MM) FOR EACH 45 (0.79 RAD) BEND AND 5 FEET (1524 MM) FOR EACH 90 (1.6 RAD) BEND. THE EXHAUST DUCT SHALL BE A MINIMUM SIZE OF 4" (102 MM) IN DIAMETER. THE ENTIRE EXHAUST SYSTEM SHALL BE SUPPORTED AND SECURED IN PLACE. FLEXIBLE DUCT CONNECTORS USED IN CONNECTIONS WITH DOMESTIC DRYER SHALL BE METALLIC, NOT MORE THAN 6 FEET (1829 MM) IN LENGTH AND AN APPROVED TYPE. FLEXIBLE DUCT CONNECTORS SHALL NOT BE CONCEALED WITH IN CONSTRUCTION. 2. ALL WATER CLOSETS TO BE 1.6 GALLON MAXIMUM. 3. ALL SLIDING GLASS DOORS TO BE TEMPERED. ALL GLASS WITHIN 24" OF A DOOR SHALL BE TEMPERED. ALL GLASS IN WET AREAS SUCH AS BATHROOMS AND KITCHENS SHALL BE TEMPERED. 4. UNLESS OTHERWISE NOTED, ANGLED WALLS ARE 45. 5. ALL MEDICINE CABINETS ARE RECESSED AND BOTTOMS ARE SET AT 54" AFF. SIZE: 14" X 18" UNLESS NOTED OTHERWISE. 6. CONSIDER ALL APPLIANCES ELECTRIC UNLESS NOTED. 7. 50 GALLON WATER HEATER UNLESS NOTED. 8. ALL CEILINGS INCLUDING GARAGE AND PORCHES TO BE 1/2" GYP. 9. ALL CEILING HEIGHTS ARE FROM FINISHED FLOOR 0'-0" AFF. PREFABRICATED WOOD TRUSSES 1. WOOD ROOF TRUSSES SHALL BE DESIGNED BY AN ENGINEER REGISTERED IN THE STATE OF FLORIDA. SIGNED AND SEALED TRUSS CALCULATIONS AND DRAWINGS SHALL BE SUBMITTED TO THE PROJECT ENGINEER FOR APPROVAL PRIOR TO FABRICATION. DRAWINGS SHALL INCLUDE CRITICAL DIMENSIONS FOR DETERMINING FIT AND PLACEMENT. DESIGN LOADING CRITERIA IS SHOWN IN THE GENERAL NOTES ON THIS DRAWING. 2. ALL TRUSSES AND OTHER ROOF STRUCTURAL COMPONENTS SHALL BE FABRICATED IN A PROPERLY EQUIPPED MANUFACTURING FACILITY OF A PERMANENT NATURE. ALL TRUSSES SHALL BE FABRICATED UNDER STRICT RULES OF THE TRUSS PLATE INSTITUTE (TPI). 3. TRUSSES SHALL BE HANDLED WITH CARE SO THEY ARE NOT DAMAGED. HORIZONTAL BENDING SHALL BE KEPT TO A MINIMUM DURING ERECTION. 4. INSTALL ERECTION BRACING TO HOLD THE TRUSSES TRUE AND PLUMB DURING CONSTRUCTION. 5. TRUSS FRAMING HARDWARE NOT SHOWN ON THE DRAWINGS SHALL BE DESIGNED BY THE TRUSS ENGINEER. ALTERNATE CONNECTORS TO THOSE SHOWN ON THE DRAWINGS MAY BE SUBMITTED FOR APPROVAL. 6. TRUSSES SHALL BE FABRICATED FROM THE FOLLOWING MATERIALS: a. CORDS SHALL BE A MINIMUM SIZE OF 2X4 AND SHALL BE #2 SOUTHERN YELLOW PINE OR BETTER. b. WEBS AND BRACING SHALL BE A MINIMUM SIZE OF 2X4 AND SHALL BE #3 SOUTHERN YELLOW PINE OR BETTER. c. TRUSS PLATES SHALL BE 20 GAGE MINIMUM WITH A MINIMUM YIELD OF 33,000 PSI AND SHALL BE G60, COMMERCIAL CLASS HOT DIPPED GALVANIZED BEFORE STAMPING. 7. MAXIMUM ALLOWABLE TRUSS DEFLECTION DUE TO THE SUPERIMPOSED LIVE AND DEAD LOADS SHOWN IN THE GENERAL NOTES OF THE CONSTRUCTION DOCUMENTS, INCLUDING SELF WEIGHT OF THE TRUSS, SHALL BE AS FOLLOWS: a. ATTACHED TO PLASTER = L/360 b. ELSEWHERE = L/240 BUILDING CODE CRITERIA BUILDING CODE: FLORIDA RESIDENTIAL CODE 2014 -EXISTING BUILDING ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2011 PLUMBING CODE: FLORIDA RESIDENTIAL CODE 2014 MECHANICAL CODE: FLORIDA RESIDENTIAL CODE 2014 LOCAL ENVIRONMENTAL REGULATION: ACI -318-08 BUILDING REQUIREMENTS FOR REINFORCED CONCRETE AISC CODE OF STANDARD PRACTICE: MANUAL OF STEEL CONSTRUCTION, 9 TH EDITION S-301 SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STEEL FOR BUILDINGS INCLUDING SUPPLEMENTS SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A-325 BOLTS STRUCTURAL WELDING CODE AWS DIA AISI SPECIFICATIONS FOR DESIGN OF LIGHT GAUGE COLD FORMED ASHRA E FOR MECHANICAL WORK OTHER STANDARDS LISTED IN THERE RESPECTIVE SECTION IN SPECIFICATIONS. ENGINEER'S NOTES DESIGN CRITERIA 2014 FLORIDA BUILDING CODE USING ASCE 7-10 1. DESIGNED FOR WIND SPEEDS OF Vult 140 MPH 2. CONTRACTOR SHALL SELECT TRUSS FASTENERS AND OTHER CONNECTORS BASED UPON THE TRUSS COMPANY'S ENGINEERED REACTIONS. 3. ASSUMED SOIL BEARING CAPACITY = 2 KSF 4. LIVE LOADS USED=20 PSF, DEAD LOADS ROOF=10 PSF ALL OTHER DEAD LOADS= ACTUAL WT. OF MATERIALS. 5. WIND IMPORTANCE FACTOR = 1.0. 6. BUILDING CATEGORY="OPEN" 7. WIND EXPOSURE = "C'. 8. TOTALLY ENCLOSED INTERNAL PRESSURE COEFFICIENT= 0.18. 9. V -B, UNPROTECTED, UNSPRINKLERED 10. COMPONENTS AND CLADDING PRESSURES, BASED ON THE ABOVE LOADING CONDITIONS, ARE SHOWN IN THE FOLLOWING TABLE R301.2(2), OF THE 2014 FLORIDA BUILDING CODE 5TH EDITION AND ASCE 7-10. z w z E W Z d m U W 0 c" to C zU) 0MN._ Z� KILN C W.6 Xdp Om mz aci Z ogZ� � a0o atr V) z 0 w RNCTTNFF.R CHAD S. LINN, P.E. #57524 P.O. BOX 140024 ORLANDO, FL 32814 PHONE: 407-252-6433 FAX: 407-392-2776 EMAIL: elinn@linnengineering.com NOTE: THE WALL FRAMING AND ROOF FRAMING WAS PERSONALLY INSPECTED AND MEETS 2014 F.B.0 5TH EDITION. RECORD COPY REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER Z. i (4 • k-7 DATE SANFORD, BUILDING DIVISION U A PERMIT ISSUED SHALL BE CONSTRUED TO BE A J LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL > CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT )^ U THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE X17-333 �V1U7ING SANFORD PA V, CEM FEB 6 2017 �- ww >w 0= U u) 1 - Lo (O d- z 0 u w J 0 z w DATE 09/16 PROJECT NO. 11300-16-100 SHEET NUMBER CS LX151 INV IN I LNNAL WALLS PROPOSED EXTERNAL WALLS n C7 z E W z O a M U rn LIJ z fA C,4 O cq co C'4 LLI z a LL N c W od XC ma am z i Z C W ogzs aac=@J mac U W w m d z Z z_ o z w � F S 0 w U o -j U J N U J U) U U Z m > r m U m C, W Q V Q w z 0 z 0 U z I- U) X W Q O J Li r . N H M U U) -j J > - ry - (0 0 O H z Q >- z 0 U W J O z_ Lil U) DATE 09/16 PROJECT N0. 11300-16-100 SHEET NUMBER FEB 6 2017 J Al BY�� -16D COMMON STAGGERED SECOND FLOOR 2X FLOOR JOIST LUS24 W/ 10D R-19 MIN. DOWN -IN INSULATION MECH. SUB TO VERIFY TO MEET--/ FL. ENERGY CODE 5/8" GYP BD CLG & WALLS WITH KNOCK [)OWN R-11 FIBERGLASS BATT INSULATION W/ KRAFT PAPER TO EXT. FACE OF WALL. MECH SUB TO VERIFY TO MEET FL. ENERGY CODE 2X4'S @ 16" O.C. W/ MID -SPAN BLOCKING 2X S.Y.P. KNEE WALL DROP CEILING DETAIL N.T.S. 26'-5" _4»�I30SH 1'-0" - 30SH L4'-9" 25'-9" SECOND FLOOR PLAN 1/4" = 1' 31'-8" I GARAGE in N A MSTA36 LVL TO JACK STUDS lvx" MSTA36 LVL TO JACK STUDS REPLACE EXISTING DOOR HEADER W/ NEW 2"X16" LVL x 12'-4"I- 12'-0" LEGEND EXISTING EXTERNAL WALLS EXISTING INTERNAL WALLS PROPOSED EXTERNAL WALLS B FIBERGLASS SHINGLES TO MATCH EXIST. OVER 30# FELT 7'-1 1/2" STORAGE N m • t MECH. ROOM Lo 5'-9°' STORAGE 00 I I 00 (D /1) (D N u „ 266- 00 66 00 (.D in O x ° °- X X X NOOK x r X —17'-2"T Q`3 11/2" 1 -9' -ll 1 2" 1- o_ 2868 / -1 X, 11� 17'-2" �BATHRO� N u, 5' KITCHEN j 6'-2" CD 00 PANTRY N 1 I , N OR/ 7'-2 11--4 1/12 11 23 SH, 33 SH, 23 SH 12'-5"1 23 SH, 33 SH, 23 SH 12'-4" HTTSK7 LVL TO LINTEL V5 1n REPLACE EXISTING ROTTEN BEAM W/ 4-2"X18" LVL W/ I 1/2 THRU-BOLTS @24" N STAGGERED. <v GREAT ROOM o 0 0 10 26'-9"— . � I N HTTSK7 LVL cn TO LINTELCO o M I 22'-10" 3'-5" 1'- 4'-8"-- 10'-2" 0 4'-6 I N �, i-V,�4'-0» �--5'-0 2'-7" " 10'-2" ' Go 0O - FOYER O BEDOOM BEDROOM I coa co O co - 1- 5'-8'- ;� 18'-0" 5068 5'-2" %n >_ 3'-7" 1 30501— 5'-6" % 5'-3"�I 30401 3'-0" 1 N I -5 3 41" LAUNDRY DINING ROOM w ROOM/ STORAGE o r7 cD iD— I 18'-6" N 2'-8" 1 3030 11'-51" 3068 p-1 1/k 3068 1-9'- 1 9'-1 1 "-1 30301-6'- 1 " -1 3030 T-4 1/21" NOTE: VALLEY FL+SHING SHALL BE 26 GA. GALV. FIRST FLOOR PLAN 1/4" = 1' 1/2" PLY PLYWOOD OR OSB -TRUSSES @ 24" O.C. -INSUL. BAFFLE @ EAVE VENTS WHERE ROD MT512 FROM TOP PLATE TO TRUSSES G.I. DRIP EDGE R-19 MIN. BOWN-IN INSULATION __/ MECH. SUB TO VERIFY TO MEET �J FL. ENERGY CODE 5/8" GYP BD CLG & WALLS WITH KNOCK DOWN _ R-11 FIBERGLASS BATT INSULATION W/ KRAFT PAPER TO EXT. FACE OF WALL. MECH SUB TO VERIFY STUCCO FINISH TO MEET FL. ENERGY CODE 2X4'S @ 16" O.C. W/ MID -SPAN BLOCKING 30# FELT OVER 1/2" EXT. PLYWOOD OR OSB. NAIL W/ 10d NAILS @ 6" O.C. BLOCK ALL EDGES �OONWINv� TYR WALL DETAIL N.T.S. NOTES 2" X 8' X 8" 16d COMMON @ 16" O.C. @ TOP & BOTTOM EDGE (REF. TABLE 2306.1 SBCCI) 1/2" X 8" PLYWOOD TYPICAL HEADER DETAIL I. TRUSSES MUST BE CAPABLE OF TRANSFERRING ¢' LATERAL LOADS TO BEARING WALLS. I I ZONE CHART W U Z ROOF EDGE 2, TRUSSES, GIRDERS, AND BEAM TIE DOWNS TO BE SIZED PER TRUSS MANUFACTURER'S UPLIFT O � N LL N C O O CALCULATIONS. ANY QUESTIONS AS TO THE SIZE, Z mood TYPE OR VALUE OF A NAIL, STRAP OR CLIP Z Ili N SHOULD BE VERIFIED BY THE STRUCTURAL ENGINEER. O O 3. HEADER STUD REQUIREMENT mac U 2 HEADER STUDS (EA SIDE) V-6" TO 6'-0" o 2 w m 3 HEADER STUDS (EA SIDE) 6'-0" TO 12'-0" RIDGE O V) 4 HEADER STUDS (EA SIDE) 12'-0" TO 18'-0" O 1 1 z w 0 2 HEADER STUDS REQ. (1) FULL LENGTH STUD L W v o Li 3 HEADER STUDS REQ. (2) FULL LENGTH STUDS 4 HEADER STUDS REQ. (2) FULL LENGTH STUDS � U J N v 2 2 Of 4, BEARING WALL NAILING PATTERN JQ z m PLYWOOD OR O.S.B.: r m ® OO OO OO FIELD — 8d NAILS @ 12" O.C. m Z a EDGE — 8d NAILS @ 6" O.C. 6. 1/2" GYPSUM BD CEILING — 5d NAILS @ 7" O.C. GYPSUM y U FIELD — 5d NAILS @ 10" O.C. 7. SENCO 2-1/4" x .131 & PASELODE 2-1/4" x .099 PNEUMATIC NAILS MAY B EDGE — 5d NAILS @ 7" O.C. USED IN LIEU OF 8d COMMON NAILS, NAILED @ 5" O.C. EDGES & AT 10" O.C. FIELD. 5. ROOF NAILING PATTERN, PLYWOOD OR O.S.B.: 8, ALL INTERIOR LOAD BEARING WALLS TO BE 2x4 #2 SPF @ 24" O.C. MAX. UP Oi ZONE 1 — 8d RING SHANK NAILS @ 6" O.C. TO 14'-0" HT. INTERIOR LOAD BEARING WALLS ABOVE 14'-0" HT TO BE 2x4 #2 SPF @ 16" O ZONE 2 — 8d RING SHANK NAILS @ 6" O.C. O.C. MAX U.O.N. O ZONE 3 — 8d RING SHANK NAILS @ 6" O.C. 9, TABLE 2306.1 OF THE STANDARD BUILDING CODE 2014 5TH ED., NAILING REQUIREMENTS ARE IN ADDITION TO STRAPPING REQUIREMENTS. NAIL PATTERNS - 11111111 U) E W Z M U W U Z N w C z O � N LL N C Lu -a xoo m Z mood w Z Ili N oIz' z 10-1 mac U o o w m = LL z z W V) U z w 0 j L W v o Li ui F- � U J N v J v CD L- `t Of U Z z m Of r m U) 0 Z m Z a LJ (f) 0 0 y U O 0 W w O z Ld W v7 DATE z E W Z M U W U Z N w C h z a O � N LL N C Lu -a xoo m Z mood Z Ili N oIz' o tt = @) 10-1 mac U w w m = LL z z W z a Cdr r Q -' z w 0 L W v o � ui F- � U J N v J v CD L- `t o Z z m Q r m U) 0 Z m Z 0 w LJ (f) 0 0 y U O 0 LL 4 r N �-- co U J = LL J L (fl p CD L- `t Z Q � z E O W O z W v7 DATE 09/16 PROJECT NO. 11300-16-100 :CEIVE,.; SHEET NUMBER FEB B 2012 A2 ID T a ai rn 0 s in m N I O 0 M i v 0 n i N E 0 c 3 0 0 7 STAIR FINISH DETAIL SCALE 3/4' = V 6 STAIR FINISH DETAIL SCALE 3/4' = V a 4a GR❑❑VE DETAIL SCALE 1 1/2' = F 0 LEGEND NOTE, CARPET STRIP AT CENTRAL OF J STAIR ONLY HARDWOOD EDGES. VERIFY DIMENSION AY SIDES O2 DOUBIF P X FLOOR JOISTS 03 PLYWOOD SUBFLOOR 40 FLOOR JOIST 2 X 6 BLOCKING O6 INTERIOR ONE HOUR' RATED FINISH WHERE 0CCURING NOTE,COVE MOLDING NOT SHOWN FOR CLARITY, BELOW NOSING,SEE DET. ##1 O8 1' LIP MAXIMUM OHARDWOOD FLOORING AND NOSING 10 2X FLOOR JOIST SEE FRAMING PLAN it 2X STAIR STRINGER SEE PLAN 12-SIMPSON' HU HANGER 13 2X12 STAIR STRINGERS AT 12' O.C. `.✓/ ONE ADJSCENT TO WALL TYPICAL EACH SIDE 14 CARPET TACK STRIP TOP AND BOTTOM AS REQUIRED TYPICAL 15 CARPET OVER PLYWOOD OR HARDWOOD VERIFY IN THE FIELD. 16 CUT PLYWOOD RISED OR TREADS,FASTEN TO 2X STAIR STRINGERS `+✓/ GLUE AND DRYWOD SCREWS 117 BRASS CARPET HOLDOW N TYPICAL AT INSIDE OF INSIDE BOTTOM OF EACH STEP 18 NOTE: ALLOW FOR FINISH ON PLYWOOD 19 CERAMIC TILE 2p BOND COAT 21 MORTAR BED: 3/4'MIN. - 1 1/14' MAX. 2a SCRATCH COAT 23 METAL LATH ?4 WATERPROOF MEMBRANE DESIGN REQIUREMENTS 025 USE COVE TIII-E AT JUNCTION OF RISER AND TREAD FORMAINTAINING QUARRY OR PAVER TILE. COVE: SET HORIZONTALLY OR VERTICAL TO FACILITATE LAYOUT 20 ?7 FINISHED STEP NOSINGS ARE AVAILABLE 0 IN SPECIALLY SHAPED QUARRY AND PAVER TILE PIECES 28 USE FULL RADIUS CERAMIC MOSIAC BULLNOSE TILE FOR NOSINGS 29 SLIP RESISTANT TILE REQUIRED ON STAIR TREADS TYPICALLY 30 ALTERNATE EXTERIOR GRADE PLYWOOD RISER / TREAD 031 SIMPSON' HU JOIST HANGERS DOUBLE BLOCKING TO FLOOR JOIST 32 NOTE: ALL PLYWOOD EXTERIOR GRADE TYPICAL 3/4' CDX 33 FINISH CONCRETE WITH MEDIUM ROUGH BRUSH. 34 HAMMER FINISH FREE OF CRACKS,WAXY OR OILY FILMS AND/OR CURING COMPOUNDS 35 LIGHT BROOM FINISH TYPICAL 36 3/4' RADIUS TOP AND BOTTOM TYP, 37 3/8' DIA. I_AG BOLT 38 2X4 STUDS AT 16' O.C. TYPICAL(WALL) 39 INTERIOR FINISH 40 1 1/4' DIA.STD, PIPE HANDRAIL(VERIFY W/ OWNER, WOOD SIM.) 41 2X BLOCKING W/ 2 1/2' FH WD. SCREWS AT 4' O.C. TYPICALLY 42 TOOL SAFETY GROOVES STOP TOOLS 3' FROM EACH END OF TREAD,OMIT GROOVES IF SCHED OR DET. CALLS FOR OTHERWISE 43 CAPPED END, WELD AND GRIND SMOOTH 44 METAL BRACKET 45 VERIFY WALL THICKNESS SEE PLANS 46 INTERIOR FINISH ONE HOUR RATED AT STAIR 47 ALT, INSULATE UNDER SIDE OF STAIRS W/ R-19 BATTS 48 SEE STRUCTURAL FOR SLAB THICKNESS AND REINFORCING 49 MOLDING 50 1 1/8'X1 3/8' WOOD WALL STRINGER 51 3/4' PLYWOOD TREAD. 52 BALLISTER DOVETAILED INTO TREAD 53 COVE MOLDING 54 2X12 STRINGERS AT 12' O.C. W/4-16cf AT EACH STUD ALT. 3' USE DRYWALL SCREWS 55 1 1/2' OUTER FINISH WOOD STRINGER 56 INSULATE STAIR WALLS W/ R-11 SOUND BATTS 57 58 ALT 7 Eel STAIR SECTI❑N AT WALL D 4 WOOD STAIR DETAIL SCALE 1 1/2' = Y E SECTI❑N f LHIV V 1G. W ELEVATI❑N RAIL END RETURN 3 STAIR RAILING SCALE 3' = 1' STAIR NOTES 1, HANDRAILS A. PROVIDE HANDRAIL - MINIMUM ONE SIDE B. HEIGHT OF RAILING ABOVE TREADS - 32' (30' MIN. - 34' MAX.) C. EXTEND HANDRAILS 12' NOSING OF TOP TREAD AND 12' PLUS TREAD WIDTH BEYOND THE BOTTOM NOSING, D. RETURN AND TERMINATE ENDS OF HANDRAILS TO WALL OR POST. E. PROVIDE 1 1/2' CLEAR BETWEEN HANDRAIL AND WALL. F, CROSS-SECTIDNAL DIMENSION HAND GRIP PORTION OF HANDRAILS: 1 1/4' MINIMUM. 2, TREADS A. ALL TREADS SURFACES ARE TO BE SLIP RESISTENT B. ALL EXPOSED EDGES OF TREADS ARE TO BE SMOOTH,ROUNDED OR CHAMPHERED. NO ABRUPT EDGES AT LOWER FRONT EDGE OF NOSING 3, N❑SING A. NOSING PROJECTION PAST FACE OR RISER BELOW TO BE 1 1/2' MAXIMUM. 4, RISERS A. SUFFICIENTLY SOLID TO PREVENT PASSAGE OF OBJECTS LARGER THAN 1/4', 5, DIMENSI❑NS (UNLESS NOTED OTHERWISE) A. RISERS: 7 1/2' MAX. VERT., 4' MIN. B. TREADS: 10' MINIMUM HORIZONTAL , 6, MAXIMUM VARIATION IN HEIGHT OF RISERS OR WIDTH OF TREADS IN ANY GIVEN FLIGHT: 1/4' 7, MINIMUM HEADROOM CLEARANCE MEASURED VERTICALLY FROM THE PLANE OF THE CEILING FINISH TANGENT TO THE TREAD N❑SING AT THE STAIRWELL : 6'-8' MINIMUM CLEAR 8, MAXIMUM VERTICAL DISTANCE BETWEEN STAIRWAY LANDINGS: 12'-0' 9, STAIR LANDINGS: A. STAIR LANDINGS SHALL BE THE SAME WIDTH AND DEPTH AS THE STAIR IT SERVES WITH MINIMUM DIMENSIONS OF 36' EACH WAY. B. PROVIDE HANDRAIL AT STAIRS AND 36'HIGH GUARD RAIL(42' HIGH MINIMUM IF OCCUPANCY LOAD IS HIGHER THAN 10)AT STAIR LANDINGS WITH CLEAR SPACE BETWEEN BALLUSTERS AND HORIZONTALTOP RAIL AT 4' MIN. CLR. TYPICAL 10, SEE INTERI❑R FINISH SCHEDULE DETAILS AT PLANS FOR STAIR FINISHES, 11, HANDICAPPED COMPLIANCE: A. MARK WITH A 2' WIDE STRIPE OF CONTRASTING COLOR PARALLEL TO AND NOT MORE THAN 1' FROM THE NOSE OF THE STEP OR LANDING. THE UPPER APPROACH AND LOWER TREAD OF EACH STAIR.USE A SLIP RESISTANT MATERIAL FOR THE STRIP AT EACH NOSING AND LANDING, 12, ENCLOSED USABLE SPACE UNDER STAIRS: A. SHALL BE PROTECTED WITH ONE-HOUR FIRE RESISTIVE PROTECTION. J I HIK r IIVIJI-1 IJL I HIL SCALE 1 1/2' = 1' .I1 WOOD ST SCALE 1 1/2" = 1' ECEIVI FEB 6 2017 to z O Ln Li tY z E cr W z R W N W m c z (n OLU a M N z a r LL N C W oil O O a rn mz d F ---i Z jyj c ogz-� n ir= dU I°'.1 M w � z QCD o w U o w 1� J J J Li n (n F-- U U U U m ' z } m In o m o W y z z U (n CD VI � O 2 U r . N {— M U U) J = J LL \ /In U) (0 p C) LL 7 z O U W J O z W (n DATE 09/16 PROJECT NO. 11300-16-100 SHEET NUMBER A3 Li LEGEND JUNCTION BOX Fil BREAKER PANEL NiQ PROPOSED DUPLEX OZ LIGHT SWITCH $ CEILING FAN W/ LIGHT SMOKE DETECTORS LIGHT OO link `-GFCI OUTLET =7-j / 1 / 1 ( GFCI OUTLET 1 I I GARAGE I � / 1 I / GFCI OUTLETS—\\I / I/ ( GFCI OUTLETS I I II \STORAGE \\ \ 1 \ 7 "Ilk SECURITY LIGHTS ' SECURITY LIGHTS xn x HVAC SUB ; x PANEL STORAGE / X I Xx Mp�'1Z1x////x/Z// R \ v *GREAT ROOM --_—�� x x x i X / x ® �� NOOK x X x GFCI OUTLET x /EXHAUST FAN W/ x / LIGHT COMBO / u X6 AlloffiffillummIll'I'l x% - x 0 x x / I x X BA R0� // GFCI OUTLETS x x X' ' I KITCHEN x / x 1\ / BEDOOM / FOYER x ST OOR x NEL x ; x PANTRY/ / 1 x 1\ BEDROOM X X XX — — x x X GFCI 0 TLET 220 DRYER \ \ > X TO BE N \ > xINDEPOUTLET EN ENT% I DINING ROOM \I v CIRCUIT I / > LAUN RY / ROOM/ TORAGEJ x x — x SECURITY LIGHTS FIRST FLOOR ELECTRICAL PLAN A#Al._ Al ELECTRICAL NOTES 1. PROVIDE SMOKE DETECTORS ADJACENT TO AND IN ALL SLEEPING ROOMS. NO MONOXIDE DETECTION REQ'D. 2. ALL SMOKE DETECTORS SHALL BE HARD WIRED W/ A MINIMUM OF 30 VOLTS AC, BATTERY BACK UP AND INNER WIRE, WHEREAS ANY SMOKE DETECTOR ACTIVATED WILL CAUSE ALL OTHERS TO ACTIVATE. 3. CABLE T.V. & TELEPHONE RECEPTACLE LOCATIONS SHALL BE VERIFIED W/ OWNER BY CONSTRUCTION JOB SUPERINTENDENT ON SITE OR DURING CUSTOMER PLAN REVIEW. 4. ELECTRICAL METER LOCATION IS EXISTING 5. ALL APPLIANCES ARE ECLECTIC 6. ITEMS SHOWN ON THIS PLAN ARE FOR BIDDING PURPOSES ONLY. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MEETING ALL FLORIDA BUILDING CODES ELECTRICAL SPECS 1. ALL WIRE FROM METER THROUGHOUT THE HOUSE IS COPPER WHEN THE SERVICE IS BACK TO BACK. IN THE EVENT WRONG END SERVICE IS REQUIRED. 2. TELEPHONE LINES ARE (3) PAIR TWISTED AND ARE LOOPED THROUGHOUT THE HOUSE AND TERMINATED AT THE ELECTRIC SERVICE. 3. ALL T.V. LINES ARE HOME RUNS TO SCUTTLE HOLES. T.V. CABLE TO BE RG -6. 4. ALL CEILING FANS ARE PRE -WIRED FOR FAN AND LIGHT AND SWITCHED BASED ON THE SERIES OF THE HOME. 5. SWITCH AND RECEPTICLE HEIGHTS ARE AS FOLLOWS: A. STANDARD OUTLETS ARE 20" TO THE TOP. B. STANDARD SWITCHES ARE 42" TO THE TOP. 6. JUNCTION BOXES WILL NOT BE INSTALLED ON THE FRONT OF ANY BUILDING FOR ANY REASON, ANY CONNECTIONS OUT OF THE FRONT, MUST BE SLABBED IN OR LOOPED AROUND FROM THE SIDE OF THE BUILDING FROM A JUNCTION BOX. 7. RECEPTACLES TO ARC FAULT PROTECTED AND TAMPER RESISTANT PER 201 1 NEC 210.2 AND 406.11 SECURITY LIGHTS SECURITY ' LIGHTS �c'V FEB 6 2017 ft'p z 0 co z W Z M v W 0 c" c FE N Ci N z 0 T J N d ww ca x0o Orn �1 mC= z Z u c d5Zs a it 0 o a = Li W C m z z w o z Q o C3o U J J U U U U Z m } } m U) o m o w Z Z Y goo T_ ti . N I— M J = U_ J > L —CDO O L_ Ntz Q � z 0 u w J O z w DATE 09/16 PROJECT NO. 11300-16-100 SHEET NUMBER E1 FIRST FLOOR HVAC PLAN 1/4" = 1' W F - Q Z E W Z V U Zfn m c C7 N Z U. CV C W od XOo 07 m zC d Z W ogzs n oc0U M®I o a U f . N U � � J � � Lo U) -r-- L6 co p O L!_ It z Q � U ~ z 0 U LEGEND w 0 z HVAC RETURNFz-1 w DATE 09/16 HVAC SUPPLY REGISTER PROJECTN0. 11300-16-100 SHEET NUMBER ul IV� FEB 6 zoir M1 -- a 01 3 N N O Q] t CO U) 0 O O U N O 1 n N E U C 3 U r)