Loading...
HomeMy WebLinkAbout241 Bellagio Cir 18-549 Interior remodelTENANT IMPROVEMENTS FOR SPA DIVA, LLC 241 Bellagio Circle Sanford, Florida 32771 January 18, 2018 OWNER SPA DIVA, LLC 241 Bellagio Circle Sanford, Florida 32771 ARCHITECT BLANKENSHIP ARCHITECTS INCORPORTATED 540 Lake Faith Circle Maitland, Florida 32751 Phone 407.331.8868 nelson@blankenshiparchitects.com JOSEPH LAWRENCE & CO, LLC MECHANICAL 138 WEST JESSUP AVENUE ELECTRICAL & LONGWOOD, FL 32750 PLUMBING 321.972.4466 INGENGINEER CONTACT: ADAM BARNEY 407.454.1911 CELL 123 GENERAL CONTRACTOR JL STONE CONSTRUCTION Orange City, Florida 32763 North Industrial Drive Phone 386.473.0161 Contact: Bryan Swoape 540 LAKE FAITH CIRCLE B L AN KEN S H I P MAITLAND, FL 32751 PH. 407.331.8868 Registration AA 26001666 ARCHITECTS on 4A260.1W nelson@blankenshiparchitects.com INCORPORATED copyright Q LOCATION MAP f�eo�Ecr N NORTH NO SCALE SHEET INDEX NUMBER SHEET TITLE PERMIT ISSUE REVISED REVISED COVER SHEET & INDEX 03-02-17 ARCHITECTURAL A 101 1 FIRST FLOOR PLAN PLUMBING P-001 SYMBOLS, LEGEND & NOTES - PLUMBING P-201 FLOOR PLAN - PLUMBING E-301 SCHEDULES, DETAILS & RISER - PLUMBING ELECTRICAL E-001 SYMBOLS, LEGEND & NOTES - ELECTRICAL E-201 FLOOR PLAN - ELECTRICAL GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES, SPECIFIC BUILDING RESTRICTIONS AND INDUSTRY CONSTRUCTION STANDARDS AND SPECIFICATIONS. 2. FOR THESE DOCUMENTS, THE TERMS'OWNER' AND 'TENANT' ARE INTERCHANGEABLE. 3. GENERAL CONTRACTOR IS TO MAINTAIN LIFE SAFETY AND EMERGENCY EGRESS FUNCTIONALITY DURING CONSTRUCTION. GC SHALL PROVIDE CONSTRUCTION BARRIERS AS REQUIRED AND COORDINATE WITH TENANT. 4. DIMENSIONS AND CONDITIONS INDICATED IN THESE DRAWINGS ARE BASED ON DOCUMENTS AND INFORMATION PROVIDED. GC SHALL VERIFY EXISTING ACTUAL CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT / TENANT OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIALS AND COMMENCEMENT OF WORK. 5. PROTECT ALL EXISTING MATERIALS AND FURNISHINGS DESIGNED TO REMAIN. DAMAGED ITEMS SHALL BE REPLACED COMPLETELY BY THE GENERAL CONTRACTOR TO THE ITEM'S CONDITION AT COMMENCEMENT OF THE PROJECT. CONSTRUCTION PERFORMED ADJACENT TO EXISTING MATERIALS SHALL BLEND IN TEXTURE, FINISH AND COLOR WHEN FINISHED SO AS TO NOT BE DETECTABLE. 6. IF POWER MUST BE CUT OFF TEMPORARILY, NOTIFY THE TENANT 24 HOURS MINIMUM IN ADVANCE OF THE SCHEDULED CUT OFF TIME. 7. DURING CONSTRUCTION, GENERAL CONTRACTOR SHALL PARK VEHICLES AND EQUIPMENT, ETC. IN A LOCATION APPROVED BY TENANT. 8. DIMENSIONS SHOWN ARE TO FACE OF CONCRETE, CONCRETE MASONRY UNITS (CMU) OR FACE OF STUDS UNLESS NOTED OTHERWISE (UNO). - - SANFOR_D B_ UI�QING-- IIJ�SION 414)(o ccw Awl' (')"'e _ BFRNIIT jSSjED SHALL BE. CONSTRUED TO BEA (� WITH THE WORK AND NOT AS /� I CENSE TO PROCcED CANCEL. ALTER OR SET AUTHORITY TO VIOLATE' F THE TECFI"lICAL PERMIT #_ 1�, r,S!DE ANY OF THE PROVISIONS 0 _ \ ^,ODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM TP. EREAFTER TION PFOUIRING A CORRECTION OF EPRORS IN PLANS' CONSTRUCTION OR VIOLA CF THIS CODE U . U ni:FiCE EXISTING 8'-0' WALLS EX ELEC PANE ING WALLS EXISTING 4'-6' WALLS FIRST FLOOR EXISTING / DEMO FLOOR PLAN SCALE: 1/8"=1'-0" ®J E THIS PROJECT 15 THE MODIFICATION OF AN EXISTING OFFICE SPACE INTO A BEAUTY SALON. NO WALLS ARE BEING CHANGED. ONE EXISTING SINK IS BEING RELOCATED AND TWO NEW PEDESTAL SINKS ARE BEING INSTALLED WITH LIMITED ELECTRICAL ASSOCIATED WOFK A NEW 1 ,((�vv r� BASESINK- WALLSBIEARE BT 15 EING NG INSTALLED D E S 1. PIP 1 I 0 N AND FOR MAINTENANCE PURPOSES IN ROOMS 101,108 E 109 OLD DESCRIPTION EXISTING CARPET HAS REPLACED WITH NEW PORCELAIN TILE. CODE ANALYSIS CODES IN EFFECT FLORIDA BUILDING CODES, 6 TH EDITION FLORIDA FIRE PREVENTION CODE, 6TH EDITION NATIONAL ELECTRIC CODE 2014 Applicable State, Federal and Local Codes and Regulations 5U5JECT ENCE FLORIDA BLDGRCODE APPLICATION PROVIDED CLASSIFICATION OF WOR, EXISTING BLDG SECTION 302 - ALTERATION LEVEL 2 ALTERATION LEVEL 2 OCCUPANCY FBG SECTION 304.1 5UBINF-55 BUSINESS CONSTRUCTION TYPE FBC SECTION 601 - TYPE 11-5 EXISTING NOT CHANGED AUTOMATIC SPRINKLER REQUIRED EXISTING NOT CHANGED CLA551FICATION SEPARATION EXISTING EX15TING NOT CHANGED EXITS REQUIRED FBC TABLE 1021.1 - EXISTING NOT CHANGED EXISTING NOT CHANGED EXIT TRAVEL MAX FBC TABLE 10%W - 250 FT EXISTING NOT CHANGED EXIT DEAD END LIMIT FEC TABLE 10163 - 50 FT EXISTING NOT CHANGED EGRESS (occupant load) FBC TABLE 1004.1.2 - AREA UNCHANGED EX15TING NOT CHANGED EGRESS REQUIREMENTS TABLE 1005.1 EXISTING NOT CHANGED FIRE RE515TANGE INTERIOR NON-BEARING WALLS EXISTING COLUMNS EXISTING BEAMS EXISTING FLOOR CEILING EXISTING ROOF EXISTING EXTERIOR BEARING WALLS lover 20 less 30 x��o EXISTING aQ EXTERIOR BEARING WALLS (over 30 feet) EXISTING EXTERIOR NON-BEARING WALLS EXISTING r� TENANT WALL SEPARATIONS EXISTING SYMBOL LEGEND FE FIRE EXTINGUI5HER BRACKET MOUNTED ON WALL (4-A:60:5:C, 10 LB TYPE). TOP OF c 0 .Q EXTINGUISHER 50' AFF. EXTINGUISHERS IN KITCHENS ARE CLASS 'K'. FEC g FIRE EXTINGUISHER IN RECESSED CABINET. (4=A:(a0:B:C, 10 LB TYPE) CENTER OF CABIBET AT 42' AFF. 164 EXIT DISCHARGE POINT AND NUMBER OF OCCUPANTS SERVED 60 FT TRAVEL 0 — — — — -00- EXIT PATHS AND TRAVEL DISTANCES EQUIPMENT F—gai ROOM NAME E NUMBER SECOND FLOOR EXISTING / DEMO FLOOR PLAN SCALE: 1/8"=1'-0" NEW BASE CABINET WITH RELOCATED 51Nk NEW SINK PEDA5TAL SINKS RECEPTION I I � I I I I I WAITING I Im2 I I 1 I r Imo rlP'15TANC� I I I TAIL 0- — O TOILET 106 o ® 4 MAIN SALON Im'1 I 48- T TRAVEL DISTANCE HAMPOO Ima I" I ...... ............. ........... ... .....-.............. I I I DRYER 109 At —. FIRST FLOOR LIFE SAFETY PLAN SCALE: 1/8"=1'-0" FIRST FLOOR PROPOSED FLOOR PLAN SCALE: V8"=1'-0" SECOND FLOOR LIFE SAFETY PLAN SCALE: I/8"=1'-0" SECOND FLOOR PROPOSED FLOOR PLAN SCALE: 1/8"=1'-0" a m c 0 .Q U 0 a� ro D 0 Cc C �vet��P"'�1a U W E. C) - ¢z x��o aQ MaP4rU< r� rz, "� a •r I -r-1 O Q P- 0 � p W �I DRAWN CHECKED RSC NBB PROJECT NUMBER 1801 DRAWING NUMBER A-101 DATE 01-10-17 LEGEND 10 DIRECTION OF FLOW IN PIPE 40�- PITCH PIPE DOWN IN DIRECTION OF ARROW �O PIPE UP O PIPE DOWN --CD- - EXPANSION JOINT o- FLEXIBLE PIPE CONNECTOR -i®�- BALL VALVE - ST - CHECK VALVE, HORIZONTAL SWING - GATE VALVE - BUTTERFLY VALVE �J- GLOBE VALVE - -SCW - - BALANCING VALVE -{�BC BALANCING COCK -I �-1- STRAINER, Y -TYPE AND BLOWOFF VALVE RV PRESSURE RELIEF VALVE (WATER) - PRESSURE REDUCING VALVE b PRV MAV MANUAL AIR VENT m O $ -�4 SOLENOID VALVE VALVE OS & Y E CAPPED LINE - SAN - SANITARY SEWER (ABOVE GRADE) - - SAN - - SANITARY SEWER (BELOW GRADE) - DOMESTIC COLD WATER BP- BOOSTED PRESSURE DOMESTIC COLD WATER ---- DOMESTIC HOT WATER ----- DOMESTIC HOT WATER RETURN --CD- - CONDENSATE DRAIN (BELOW GRADE) _CD- CONDENSATE DRAIN (ABOVE GRADE) - - ST - - STORM SEWER (BELOW GRADE) - ST - STORM SEWER (ABOVE GRADE) - EO- STORM EMERGENCY OVERFLOW PIPING - -GR - - GREASE SEWER (BELOW GRADE) -GR - GREASE SEWER (ABOVE GRADE) - -SCW - - SOFT COLD WATER -�� VENT --G-- GAS LINE (BELOW GRADE) -G- GAS LINE (ABOVE GRADE) ® POINT OF CONNECTION NEW FD ® TO EXISTING ® POINT OF REMOVAL FOR DEMOLITION OT DELTA T (TEMPERATURE DIFFERENCE) PHOTO DETAIL OR SECTION IDENTIFICATION TARGET B A =DETAIL NUMBER. B = SHEET NUMBER ON WHICH DETAIL IS LOCATED. HB HOSE BIBB FD ® FLOOR DRAIN HD O HUB DRAIN TO ® TRENCH DRAIN --A-- COMPRESSED AIR (BELOW GRADE) A COMPRESSED AIR (ABOVE GRADE) FLOOR CLEANOUT r CLEANOUT -- EXTERIOR CLEANOUT -�� HORIZONTAL CLEANOUT AR's. ITEMS TO BE REMOVED (DEMOLITION) -CWN - COLD NANO WATER CWF - COLD FILTERED WATER SHOCK ABSORBER NOTE: SYMBOLS SHOWN ON THIS PLUMBING LEGEND ARE FOR REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLS MAY NOT BE USED FOR THIS PROJECT. SPECIFICATIONS PART 1 - GENERAL 1.1 SECTION INCLUDES A. GENERAL PROVISIONS SPECIFICALLY APPLICABLE TO DIVISION 15 SECTIONS, IN ADDITION TO DIVISION 1 - GENERAL REQUIREMENTS. 1.2 SCOPE A. THE WORK SHALL INCLUDE THE PROVISIONS OF SYSTEMS, EQUIPMENT AND MATERIALS SPECIFIED IN THIS DIVISION AND AS CALLED FOR ON THE DRAWINGS. WORK SHALL ALSO INCLUDE SUPERVISION, OPERATION, METHODS AND LABOR FOR THE FABRICATION, START-UP AND TESTS FOR A COMPLETE OPERATIONAL PLUMBING INSTALLATION. B. DRAWINGS FOR THE WORK ARE DIAGRAMMATIC IN NATURE AND ARE INTENDED TO CONVEY THE SCOPE OF THE INSTALLATION AND TO INDICATE THE GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK. BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS SUCH AS PIPE FITTINGS, ACCESS PANELS, AND SLEEVES MAY NOT BE SHOWN. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR SELECTING THE EQUIPMENT TO FIT THE SPACE PROVIDED. THE LOCATION AND SIZES FOR PIPE FITTINGS, SLEEVES, INSERTS, FIRE AND/OR SMOKE DAMPERS, AND OTHER BASIC ITEMS REQUIRED BY CODE AND OTHER SECTIONS SHALL BE COORDINATED AND INCLUDED FOR THE PROPER INSTALLATION OF THE WORK. C. EQUIPMENT SPECIFICATIONS MAY NOT DEAL INDIVIDUALLY WITH MINUTE ITEMS REQUIRED SUCH AS COMPONENTS, PARTS, CONTROLS AND DEVICES WHICH MAY BE REQUIRED TO PRODUCE THE EQUIPMENT PERFORMANCE SPECIFIED OR AS REQUIRED TO MEET THE EQUIPMENT WARRANTIES. WHERE SUCH ITEMS ARE REQUIRED, THEY SHALL BE INCLUDED BY THE INSTALLER OF THE EQUIPMENT, WHETHER OR NOT SPECIFICALLY INDICATED IN THE CONTRACT DOCUMENTS WITH NO ADDITIONAL COST INCURRED. D. WHERE NOTED ON THE DRAWINGS OR INDICATED IN OTHER SECTIONS OF THE SPECIFICATION, THE CONTRACTOR FOR THIS DIVISION SHALL INSTALL PLUMBING EQUIPMENT FURNISHED BY OTHERS, AND SHALL MAKE ALL FINAL CONNECTIONS. CONTRACTOR SHALL INSTALL EQUIPMENT AND SYSTEMS IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. E. COORDINATE WITH ALL TRADES IN SUBMITTAL OF SHOP DRAWINGS. TIGHT SPACE CONDITIONS SHALL BE DETAILED TO THE SATISFACTION OF ALL TRADES, SUBJECT TO THE REVIEW AND FINAL ACCEPTANCE OF THE ARCHITECT/ENGINEER. IN THE EVENT THAT THE CONTRACTOR INSTALLS HIS WORK BEFORE COORDINATING WITH OTHER TRADES OR SO AS TO CAUSE ANY INTERFERENCE WITH THE WORK OF THE OTHER TRADES THIS CONTRACTOR SHALL MAKE ALL REQUIRED CHANGES TO CORRECT THE CONDITION AT NO ADDITIONAL COST TO THE PROJECT. F. CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTION SIZES PRIOR TO INSTALLATION OF ANY SYSTEMS. THIS CONTRACTOR SHALL ADJUST PIPING SYSTEM SIZES AS REQUIRED TO MATCH EQUIPMENT CONNECTIONS. UTILIZE REDUCERS WHERE EQUIPMENT CONNECTIONS ARE SMALLER THAN PIPE SIZES INDICATED ON PIANS, NO PIPING SHALL BE DECREASED IN SIZE (IN THE DIRECTION OF FLOW). 1.3 EXAMINATION OF BIDDING DOCUMENTS: A. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY AND NOT LATER THAN TEN (10) DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO THE ENGINEER FOR INTERPRETATION OR CORRECTION OF ANY AMBIGUITY, INCONSISTENCY OR ERROR THEREIN. ANY INTERPRETATION OR CORRECTION WILL BE ISSUED AS AN ADDENDUM BY THE ENGINEER. ONLY A WRITTEN INTERPRETATION OR CORRECTION TO BID DOCUMENTS BY ADDENDUM SHALL BE BINDING. NO BIDDER SHALL RELY UPON ANY INTERPRETATION OR CORRECTION GIVEN BY ANY OTHER METHOD. 1.4 SUBSTITUTIONS: A. EXCEPT AS PROVIDED BELOW, EACH BIDDER REPRESENTS THAT HIS BID IS BASED UPON THE MATERIALS AND EQUIPMENT DESCRIBED IN THE BIDDING DOCUMENTS. B. NO SUBSTITUTIONS FOR OTHER MATERIALS AND EQUIPMENT WILL BE CONSIDERED UNLESS WRITTEN REQUEST HAS BEEN SUBMITTED TO THE ENGINEER FOR APPROVAL AT LEAST TEN (10) DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS. EACH SUCH REQUEST SHALL INCLUDE A COMPLETE DESCRIPTION OF THE PROPOSED SUBSTITUTE, THE NAME OF THE MATERIAL OR EQUIPMENT FOR WHICH IT IS TO BE SUBSTITUTED, DRAWINGS, CUTS, PERFORMANCE AND TEST DATA OR INFORMATION NECESSARY FOR A COMPLETE EVALUATION. C. IF THE ENGINEER APPROVES ANY PROPOSED SUBSTITUTION, SUCH APPROVAL WILL BE ISSUED AS AN ADDENDUM FORWARDED TO ALL PARTICIPATING BIDDERS. D. IF ANY BIDDER IS UNABLE TO PROCURE WRITTEN APPROVAL OF ANY SUBSTITUTION FROM THE ENGINEER PRIOR TO THE OPENING OF BIDS, THEN HE SHALL BASE HIS BID ON ITEMS AND SYSTEMS AS SPECIFIED IN BID DOCUMENTS. E. SUBSTITUTIONS REQUESTED ON THE BID PROPOSAL FORM WHICH ARE PRIOR APPROVED BY THE ENGINEER WILL BE INCORPORATED INTO THE CONTRACT WITH THE SUCCESSFUL BIDDER. F. REQUESTS FOR ANY SUBSTITUTIONS NOT SUBMITTED AND APPROVED IN ACCORDANCE WITH THE ABOVE INSTRUCTIONS WILL BE DENIED BY THE ENGINEER. 1.5 REGULATORY REQUIREMENTS: A. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE STATUTES, CODES AND REGULATIONS OF THE GOVERNMENTAL BODIES HAVING JURISDICTION. B. CONFORM TO 2014,FLORIDA PLUMBING CODE. C. CONFORM TO 2014 FLORIDA FIRE PREVENTION CODE. D. CONFORM TO 2014 FLORIDA BUILDING CODE. 1.6 CUTTING AND PATCHING: A. SUBMIT WRITTEN REQUEST IN ADVANCE OF CUTTING OR ALTERING ELEMENTS. B. EMPLOY SKILLED AND EXPERIENCED INSTALLER TO PERFORM CUTTING AND PATCHING WHICH EFFECT: B.1 STRUCTURAL INTEGRITY OF ELEMENT. B.2 INTEGRITY OF WEATHER. B.3 EFFICIENCY, MAINTENANCE, OR SAFETY OF ELEMENT. B.4 VISUAL QUALITIES OF SIGHT. B.5 WORK OF OWNER OR SEPARATE CONTRACTOR. PART 2 - PRODUCIS 2.1 PIPE HANGERS AND SUPPORTS A. MANUFACTURERS: A.1 B -LINE A.2 OTHER ACCEPTABLE MANUFACTURERS OFFERING EQUIVALENT PRODUCTS. A.2.1 MICHIGAN HANGER A.2.2 PHD 2.2 PIPING INSULATION: A. MANUFACTURERS: A.1 OWENS CORNING A.2 JOHNS MANVILLE A.3 KNAUF B. ASTM C547, RIGID MOLDED NON-COMBUSTIBLE FIBERGLASS INSULATION. 'K' VALUE .024 ® 75 DEGREES F. C. VAPOR BARRIER JACKET, KRAFT PAPER WITH GLASS FIBER YARN AND BONDED TO ALUMINUM FILM. CLOSURE SYSTEM SHALL BE UL 181. D. INSULATION THICKNESS 1-1/2'. 2.3 PIPING: SANITARY SEWER PIPING A. PVC: ASTM D2665 SCHEDULE 40 PVC SOLID WALL PIPING. A.1 FITTINGS: ASTM D2665 SCHEDULE 40 PVC DWV FITTINGS. A.2 JOINTS: ASTM D2564 SOLVENT CEMENT. JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2855. 2.4 PIPING: WATER PIPING A. COPPER PIPING: ASTM B88 TYPE 'L' HARD DRAWN. A.1 FITTINGS: ASME 16.18 CAST BRONZE OR ASME B16.22 WROUGHT COPPER OR BRONZE. A.2 JOINTS: ASTM B32 SOLDER, ASTM 95-5 TA MINIMUM, FLUX ASTM 8813. JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM 8828. A.3 SUBSTITUTIONS: CPVC IS AN ACCEPTABLE ALTERNATIVE TO COPPER ONLY IF APPROVED BY BUILDING OWNER. 2.5 PIPING: GAS PIPING A. STEEL PIPE: ASTM A 53/A 53M; TYPE E OR S; GRADE B; BLACK. WALL THICKNESS OF WROUGHT -STEEL PIPE SHALL COMPLY WITH ASME B36.10M. Al MALLEABLE -IRON THREADED FITTINGS: ASME 816.3, CLASS 150, STANDARD PATTERN, WITH THREADED ENDS ACCORDING TO ASME 81.20.1. A.2 STEEL THREADED FITTINGS: ASME B16.11, FORGED STEEL WITH THREADED ENDS ACCORDING TO ASME 81.20.1. A3 STEEL WELDING FITTINGS: ASME 816.9, WROUGHT STEEL OR ASME 816.11, FORGED STEEL A.4 UNIONS: ASME 816.39, CLASS 150, MALLEABLE IRON WITH BRASS -TO -IRON SEAT, GROUND JOINT, AND THREADED ENDS ACCORDING TO ASME 81.20.1. A.5 CAST-IRON FLANGES AND FLANGED FITTINGS: ASME B16.1, CLASS 125. A.6 JOINT COMPOUND AND TAPE: SUITABLE FOR NATURAL GAS. A.7 STEEL FLANGES AND FLANGED FITTINGS: ASME 816.5. A8 GASKET MATERIAL: THICKNESS, MATERIAL, AND TYPE SUITABLE FOR NATURAL GAS. PART 3 - INSTALLATION 3.1 INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 3.2 PROVIDE NON -CONDUCTING DIELECTRIC CONNECTIONS WHEREVER JOINTING DISSIMILAR METALS. 3.3 ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRADIENT. 3.4 INSTALL PIPING TO CONSERVE BUILDING SPACE AND NOT INTERFERE WITH USE OF SPACE. 3.5 GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS. 3.6 INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, JOINTS, OR CONNECTED EQUIPMENT. 3.7 PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND ACCESS TO VALVES AND FITTINGS. 3.8 PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT EXPOSED. COORDINATE SIZE AND LOCATION OF ACCESS DOORS WITH APPROPRIATE ARCHITECTURAL SECTION. 3.9 ESTABLISH ELEVATIONS OF BURIED PIPING OUTSIDE THE BUILDING TO ENSURE PROPER SLOPE AND COVER. 3.10 ESTABLISH ELEVATIONS OF EXISTING BURIED PIPING FOR CONNECTION TO NEW WORK TO ENSURE PROPER SLOPE AND COVER. 3.11 WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL BUILDING FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT OF ZINC RICH PRIMER TO WELDING. 3.12 EXTEND CLEANOUTS TO FINISHED FLOOR OR WALL SURFACE. LUBRICATE THREADED CLEANOUT PLUGS WITH MIXTURE OF GRAPHITE AND LINSEED OIL. ENSURE CLEARANCE AT CLEANOUT FOR RODDING OF DRAINAGE SYSTEM. 3.13 RESET SPRINKLER HEADS FROM UPRIGHT POSITION TO DOWN POSITION TO CENTER OF NEW CEILING TILE. 3.14 TORQUE ALL HUBLESS CAST IRON COUPLING IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. UTILIZE COUPLING MANUFACTURERS PRE-SET TORQUE WRENCH. 3.15 INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH FIXTURE OR BATTERY OF FIXTURES. ARRESTORS SHALL BE FACTORY FABRICATED. INSTALL ARRESTORS AND SIZE PER PLUMBING AND DRAINAGE INSTITUTE STANDARD P.D.I. WH -201. ACCEPTABLE MANUFACTURERS ZURN, JOSAM, SIOUX CHIEF. PPP INC. FOR 1-11 FU'S PROVIDE PDI -A, FOR 12-32 FU'S PDI -B, 33-60 FU'S PDI -C, 61-113 FU'S PDI -D. GENERAL NOTES 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY FITTINGS AS REQUIRED BY ALL APPLICABLE CODES AND GOVERNING AUTHORITIES. 2. CONTRACTOR SHALL VERIFY AND CORRECT AS REQUIRED TO MEET ALL CODES AND REGULATIONS ANY POSSIBLE DISCREPANCIES BETWEEN TYPE AND SIZE OF CONNECTION SPECIFIED IN PLUMBING FIXTURE SCHEDULE AND FIXTURES ACTUALLY INSTALLED ON THE SITE. 3. ALL DRAINAGE PIPING 21" AND LARGER SHALL HAVE A MINIMUM d' PER FOOT SLOPE. ALL DRAINAGE PIPING 2" AND SMALLER SHALL HAVE A MINIMUM J" PER FOOT SLOPE, UNLESS OTHERWISE NOTED. 4. VENT PIPING SHOWN ON FLOOR PLANS IS ONLY INDICATIVE EXCEPT FOR VTR LOCATIONS. 5. VALVES AND FITTINGS SHALL BE OF SAME SIZE OF LINE ON WHICH THEY ARE LOCATED, UNLESS OTHERWISE INDICATED ON DRAWINGS. 6. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES. 7. CONTRACTOR SHALL FIELD VERIFY ALL GIVEN MEASUREMENTS PRIOR TO LAYING AND CONNECTING ALL SANITARY AND WASTE PIPING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 8. AIR CHAMBERS SHALL NOT BE CONSIDERED AN EQUAL TO WATER ARRESTORS AS SPECIFIED. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FIRE RATING AND WEATHERPROOFING INTEGRITY OF ALL PIPING AND PENETRATIONS. 10. ALL WATER SUPPLY AND SANITARY LINES SHALL BE RUN AS CLOSE TO PLANS AS POSSIBLE WITH NO CHANGES IN SIZING. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY SUPPORTING DEVICES FOR ALL FIXTURES INCLUDED IN CONTRACT OR HEREIN SPECIFIED OR OTHERWISE. 12. CHANGES IN THE DIRECTION OF SANITARY PIPING SHALL NOT BE MADE WITH FITTINGS WHICH WILL CAUSE EXCESSIVE REDUCTION IN THE VELOCITY OF FLOW OR CREATE ANY OTHER ADVERSE EFFECT UNLESS PHYSICALLY IMPOSSIBLE (IE: USE OF SANITARY TEE IN A HORIZONTAL CON- NECTION, USE OF A DOUBLE SANITARY TEE IN A VERTICAL STACK, IN GENERAL, USE OF SHORT -RADIUS FITTINGS FOR BRANCH TO HOUSE DRAIN OR STACK CONNECTION). 13. ALL DRAINAGE PIPING SHALL BE MARKED WITH THE SEAL OF APPROVAL OF THE NATIONAL SANITATION FOUNDATION. 14. DO NOT PENETRATE FOUNDATIONS WITH PIPING, COORDINATE WITH GENERAL CONTRACTOR TO DROP FOUNDATIONS AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE ABSOLUTELY NECESSARY. ALL PIPING PENETRATING A BEARING WALL OR FOOTING MUST BE SLEEVED AND LOCATION APPROVED BY STRUCTURAL ENGINEER. 15. ROUTE ALL PIPING CONCEALED ABOVE CEILINGS, WITHIN WALLS, OR IN CHASES. PIPING EXPOSED SHALL BE SLOPED AND PAINTED TO MATCH ARCHITECTURAL FINISHES. PIPING IN MECHANICAL ROOMS MAY BE EXPOSED. 16. PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON- ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 17. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF PLUMBING FIXTURE MOUNTING HEIGHTS, AND DIMENSIONS. 18. CONTRACTOR SHALL VERIFY INVERT ELEVATIONS OF SEWERS TO WHICH NEW SEWER LINES ARE TO BE CONNECTED BEFORE INSTALLATION OF NEW SEWER LINE. 19. ALL VENTS THROUGH ROOF SHALL BE MINIMUM OF 10'-0" FROM ANY AIR INTAKES. 20. CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS AT CONNECTIONS OF DISSIMILAR METALS. 21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS (INCLUDING PIPE ROUTING AND EQUIPMENT LOCATIONS) TO ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL PRIOR TO THE INSTALLATION OR PURCHASING OF ANY PIPING AND/OR EQUIPMENT. 22. PROVIDE 1/2" C.W. SUPPLY WITH ANGLE STOP AND FLEXIBLE SUPPLY TO RE- FRIGERATORS WITH ICE MAKERS AT HEIGHT REQUIRED BY MANUFACTURE OF EQUIPMENT INSTALLED. 23. PROVIDE 1/2" H.W. SUPPLY WITH ANGLE STOP AND FLEXIBLE SUPPLY TO DISH- WASHER MACHINE, AT HEIGHT REQUIRED BY MANUFACTURER OF EQUIPMENT INSTALLED. 24. ALL WATER PIPING INSTALLED IN EXTERIOR WALLS SHALL BE PLACED ON THE INTERIOR SIDE OF THE WALL, SO THAT WALL INSULATION CAN BE PLACED ON THE EXTERIOR SIDE OF THE PIPING. 25. WHERE EXISTING PIPING IS DESIGNATED TO BE REMOVED AND CAPPED, ALL PIPING SERVING THE DESIGNATED FIXTURE SHALL BE REMOVED FROM WITHIN WALLS TO THE POINT DESIGNATED ON THE DRAWINGS. PIPING SHALL BE CAPPED BY APPROVED CAPPING METHODS UTILIZING PIPE CAPS INTENDED FOR SUCH USE. CAPS SHALL BE AIRTIGHT AND WATERTIGHT. 26. WHERE EXISTING SURFACES ARE DISRUPTED DUE TO THE REMOVAL OF EXISTING EQUIPMENT OR PIPING, THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF DISRUPTED SURFACES TO MATCH EXISTING ADJACENT SURFACES. 27. EXISTING CONDITIONS AS SHOWN ON THE DRAWINGS ARE TAKEN FROM ORIGINAL AND AS -BUILT DRAWINGS OF THE BUILDING AND IN PART ARE UNVERIFIED. FIELD CONDITIONS SHALL GOVERN. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO INITIATION OF WORK. 28. ALL EXISTING PIPING, NOT REMAINING IN SERVICE AFTER NEW CONSTRUCTION, SHALL BE REMOVED. 29. PIPING WHICH IS TO REMAIN IN SERVICE SHALL NOT BE DISTURBED. EXISTING PIPING DAMAGED DURING CONSTRUCTION SHALL BE REPLACED WITH NEW PIPING OF THE SAME SIZE AND MATERIAL. 30. EXISTING BUILDING SEWERS THAT ARE USED WITH NEW BUILDING SANITARY SEWERS SHALL BE EXAMINED AND TESTED TO CONFORM IN ALL RESPECTS TO ALL THE REQUIREMENTS OF PLUMBING AUTHORITY HAVING JURISDICTION AND APPLICABLE PLUMBING CODES. 31. ALL EXISTING SANITARY, DOMESTIC WATER, AND RAIN WATER PIPING THAT ARE LOCATED IN EXISTING WALLS TO BE DEMOLISHED AND REMAINING IN SERVICE AFTER CONSTRUCTION SHALL BE RELOCATED TO NEW WALLS, CHASES, ETC. 32. COORDINATE WITH GENERAL CONTRACTOR TO PATCH ALL EXISTING WALLS, FLOORS, CEILINGS, ETC., AS REQUIRED BY NEW WORK. SEE SPECIFICATIONS. 33. IT IS THE PLUMBING CONTRACTORS RESPONSIBILITY TO PROVIDE A DOUBLE CHECK VALVE BACKFLOW PREVENTION DEVICE ON THE MAIN DOMESTIC WATER SERVICE PROVIDED TO THE BUILDING/SPACE UNDER CONSTRUCTION AS PER THE LATEST ADOPTED VERSION OF THE PLUMBING CODE EVEN IF THE BACKFLOW PREVENTION DEVICE IS NOT CALLED OUT SPECIFICALLY ON THE PLANS. 34. FIELD VERIFICATION OF EXISTING PIPING: ALL EXISTING PIPING SHOWN ON THE CONSTRUCTION DOCUMENTS IS BASED OFF OF VISUAL SITE INVESTIGATION AND AS BUILTS DRAWINGS OF THE EXISTING SITE AND BUILDING CONSTRUCTION. THE ENGINEER DOES NOT HAVE XRAY VISION. IT IS THE RESPONSIBILITY OF THE LICENSED PLUMBING CONTRACTOR TO FIELD VERIFY ALL EXISTING PIPING LOCATIONS, TYPES, SIZES, ELEVATIONS AND INVERTS. NOTIFY ENGINEER IF THE CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATE IN THE SPECIFICATIONS PRIOR TO THE INITIATION OF ANY WORK. IDENTIFICATION AND VERIFICATION OF EXISTING PIPING TO BE ACCOMPLISHED BY THE FOLLOWING MEANS: • MANDATORY DYE TESTING OF ALL EXISTING SANITARY, STORM AND GREASE WASTE PIPING FOR SYSTEM IDENTIFICATION. SNAKE ALL SANITARY, STORM AND GREASE WASTE PIPING FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGES. TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDING EQUIPMENT SUPPLIED OR TO BE INSTALLED. ALL IDENTIFICATION AND VERIFICATION RESULTS SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO THE INITIATION OF ANY WORK. T m 0 .Q U In 0 m O Cc U � _ y c LLQ °doo c ova, s �o o aU 0 Nelson Blankenship, AIA 7 x U u a U oQ c z Z U �I 1-� DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1801 DRAWING NUMBER P-001 DATE 01-18-18 First Floor Demolition - Plumbing SCALE: 1/4"=P-0" DEMO REFERENCE NOTES: Dl REMOVE PLUMBING FIXTURE FROM LOCATION SHOWN AND CAP ALL PIPING BELOW WITHIN WALL OR ABOVE CEILING. First Floor Renovation Plan - Plumbing SCALE: 1/4"=V-0" RENO REFERENCE NOTES: (D O 2" SANITARY, I" COLD WATER AND J" HOT WATER BELOW SLAB OVER TO HAIR STATIONS. O INSTALL NEW WATER HEATER BELOW CABINET PER MANUFACTURES RECOMMENDATIONS. O3 EXISTING AND NEW PLUMBING WITH IN WALL. m 0 .Q U Q) ro ❑ Q) 0 U u � �oaoo c LLJ = 'o S C i0 O � < O Nelson Blankenship, AIA z�1 U �4 O L\ bb z o a ¢ Q) O � p O w DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1801 DRAWING NUMBER P-201 DATE 01-18-18 OF MARK INSTANTANEOUS WATER HEATER SCHEDULE WASTE TRAP UNIT # SERVING TYPE ANUFACTURER M GALLONS KW INPUT (1 ELEMENT) IOPEERATIDONT GPH REC. ®40'F RISE VOLT/PHASE CURRENT DRAW WEIGHT (LBS.) DIMENSIONS MANUFACTURER WATER MANUFACTURER MODEL IWH-1 HAIR STATIONS ELECTRIC — 6 1.4 20 115V - 10 30 21"x14"x14.25" EEMAX 1-1/2" EMT6 NOTES: 1. PROVIDE WITH EXPANSION T & P VALVE. 1/2" ELKAY 20" x 22" SINGLE COMPARTMENT SINK, 6" DEEP BOWL, #18 GAUGE, TYPE 304 NICKEL SS SINGLE KITCHEN LRAD2022 BEAMING STAINLESS STEEL, SELF RIMMING. 'CHICAGO' #2300—CP, C.P. SINGLE CONTROL OR EQUAL LEVER HANDLE FAUCET. C.P. STRAINER WITH TAILPIECE, C.P. BRASS P—TRAP WITH WALL ARM &ESCUTCHEONS. 'BRASSCRAFT' ANGLE VALVE SUPPLY RISERS W/LOOSE KEY STOPS. WCO-1 WALL CLEAN OUT SEE PLANS SEE PLANS — — — ZURN CAST IRON CLEAN—OUT TEE, DURA COATED BODY, GAS AND WATERTIGHT ABS TAPERED 21446 THREAD PLUG AND ROUND, SMOOTH STAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW. WHA -1 WATER HAMMER — — — 1/2" SIOUX CHIEF SIZE PER MANUFACTURER'S RECOMMENDATIONS. PDI CERTIFIED. WHA -1: SIZE "A" WHA -2: ARRESTOR #650 SERIES SIZE "B" REFER TO RISER DIAGRAMS FOR ARRESTOR LOCATIONS. REFER TO SPECIFICATION FOR SELECTION METHOD. AAV -1 AIR ADMITTANCE VALVE _'o o * * - — — — — STUDOR AUTOMATIC AIR ADMITTANCE VALVE WITH VENTED ACCESS PANEL. LOCATE FULLY OP. v ',/�fPay� os�ApPhh��a?��ey j ACCESSIBLE. NOTES: 1. ALL PLUMBING FIXTURES SHALL BE SUPPLIED WITH WATTS "FLOODSAFE" AUTO—SHUT OFF CONNECTOR TYPE SUPPLY RISERS WITH BRNDED STAINLESS STEEL CONNECTORS. THIS SHALL INCLUDE ALL FAUCETS, TOILETS, DISHWASHERS &ICE MAKERS. PROVIDE FULLY ACCESSIBLE SHOCK ARRESTORS ON SUPPLIES TO ICE MAKERS AND DISHWASHERS. 24 LLJT co C O U N N O U� � a _ �oaoo a=P�o oU Nelson Blankenship, aIA V) U a W��6 �Qmn o a �7 - DRAWN DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER )80L DRAWING NUMBER P-301 DATE PLUMBING FIXTURE SCHEDULE MARK INSTANTANEOUS WATER HEATER SCHEDULE WASTE TRAP UNIT # SERVING TYPE ANUFACTURER M GALLONS KW INPUT (1 ELEMENT) IOPEERATIDONT GPH REC. ®40'F RISE VOLT/PHASE CURRENT DRAW WEIGHT (LBS.) DIMENSIONS MANUFACTURER WATER MANUFACTURER MODEL IWH-1 HAIR STATIONS ELECTRIC — 6 1.4 20 115V - 10 30 21"x14"x14.25" EEMAX 1-1/2" EMT6 NOTES: 1. PROVIDE WITH EXPANSION T & P VALVE. 1/2" ELKAY 20" x 22" SINGLE COMPARTMENT SINK, 6" DEEP BOWL, #18 GAUGE, TYPE 304 NICKEL PLUMBING FIXTURE SCHEDULE MARK FIXTURE WASTE TRAP VENT COLD HOT ANUFACTURER M DESCRIPTION WATER WATER /MODEL # HS -1 HAIR STATION 2" 1-1/2" — 1/2" 1/2" OWNER PROVIDED OWNER PROVIDED S-1 SINK 2" 1-1/2" 1-1/2" 1/2" 1/2" ELKAY 20" x 22" SINGLE COMPARTMENT SINK, 6" DEEP BOWL, #18 GAUGE, TYPE 304 NICKEL SS SINGLE KITCHEN LRAD2022 BEAMING STAINLESS STEEL, SELF RIMMING. 'CHICAGO' #2300—CP, C.P. SINGLE CONTROL OR EQUAL LEVER HANDLE FAUCET. C.P. STRAINER WITH TAILPIECE, C.P. BRASS P—TRAP WITH WALL ARM &ESCUTCHEONS. 'BRASSCRAFT' ANGLE VALVE SUPPLY RISERS W/LOOSE KEY STOPS. WCO-1 WALL CLEAN OUT SEE PLANS SEE PLANS — — — ZURN CAST IRON CLEAN—OUT TEE, DURA COATED BODY, GAS AND WATERTIGHT ABS TAPERED 21446 THREAD PLUG AND ROUND, SMOOTH STAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW. WHA -1 WATER HAMMER — — — 1/2" SIOUX CHIEF SIZE PER MANUFACTURER'S RECOMMENDATIONS. PDI CERTIFIED. WHA -1: SIZE "A" WHA -2: ARRESTOR #650 SERIES SIZE "B" REFER TO RISER DIAGRAMS FOR ARRESTOR LOCATIONS. REFER TO SPECIFICATION FOR SELECTION METHOD. AAV -1 AIR ADMITTANCE VALVE — — — — — STUDOR AUTOMATIC AIR ADMITTANCE VALVE WITH VENTED ACCESS PANEL. LOCATE FULLY TEC—VENT ACCESSIBLE. NOTES: 1. ALL PLUMBING FIXTURES SHALL BE SUPPLIED WITH WATTS "FLOODSAFE" AUTO—SHUT OFF CONNECTOR TYPE SUPPLY RISERS WITH BRNDED STAINLESS STEEL CONNECTORS. THIS SHALL INCLUDE ALL FAUCETS, TOILETS, DISHWASHERS &ICE MAKERS. PROVIDE FULLY ACCESSIBLE SHOCK ARRESTORS ON SUPPLIES TO ICE MAKERS AND DISHWASHERS. m ELECTRICAL LEGEND ABBREVIATIONS GENERAL NOTES WIRING AN D POWER PANELS 1) ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL U 0) A - AMPERES ELECTRICAL CODE (NFPA 70), AND THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING CODE. S* SWITCH ® XXX NEW ELECTRICAL PANEL A/C - AC - AIR CONDITIONING ALTERNATING CURRENT 2) CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND COORDINATE WITH EXISTING EQUIPMENT PRIOR TO ro 0 (NONE) SINGLE POLE TOGGLE SWITCH MDP MAIN DISTRIBUTION PANEL (SEE PANEL SCHEDULE)BIDDING. AFF - ABOVE FINISHED FLOOR 2 TWO POLE TOGGLE SWITCH 3 THREE WAY TOGGLE SWITCH TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION AFG - ABOVE FINISHED GRADE 3) ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABEL LISTED BY AN 0 U WP SINGLE POLE WEATHERPROOF SWITCH Effl AUTOMATIC TRANSFER SWITCH AHU - AIR HANDLING UNIT APPROVED THIRD -PARTY TESTING AGENCY. Nelson Blankenship, AIA K SINGLE POLE KEYED SWITCH P-4 C/) Q 0 a xE�44 U� om U r z� OS OCCUPANCY SENSOR SWITCH ® ELECTRICAL SYSTEMS PANEL AWG - AMERICAN WIRE GAUGE BUILDING: U M MANUAL MOTOR CONTROLLER W/O OVERLOADS XXX C - CONDUIT 4) INSTALLATION HEIGHT OF EQUIPMENT (TO CENTERLINE) ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE W SACP SECURITY ALARM CONTROL PANEL CFL - COMPACT FLUORESCENT LAMP SHALL BE: FACP FIRE ALARM CONTROL PANEL Z Q' S obc LOWER CASE LETTERS INDICATES SWITCHING DESIGNATIONS, MC MASTER CLOCK CONTROL PANEL CH - COUNTER HEIGHT RECEPTACLE = 18" QUANTITY OF LETTERS EQUAL QUANTITY OF GANGED SWITCHES PA PUBLIC ADDRESS CONTROL PANEL CLOCK = 7'-6" n IMP FIRE ALARM ANNUNCIATOR PANEL CONC - CONCRETE SWITCH = 44" COND - CONDUIT MODULAR JACK FOR WALL MOUNTED TELEPHONE = 52" MJR/KCM �* SINGLE RECEPTACLE 1801 DRAWING NUMBER E-001 DATE MODULAR TELEPHONE JACK = 18" CU - COPPER TELEVISION OUTLET = 84" GFI GROUND FAULT CIRCUIT INTERRUPTER LIGHTING DISC - DISCONNECT COMPUTER OUTLET = 18" WP WEATHERPROOF CALL SWITCH = 44" IG ISOLATED GROUND ECB - ENCLOSED CIRCUIT BREAKER REMOTE TEST STATION FOR DUCT DETECTOR = 52" C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) C = ABOVE COUNTER BACKSPLASH, COORDINATE WITH ARCHITECTURAL ELEVATIONS AND MILLWORK. ®XXLIGHTING FIXTURE ELEC - ELECTRICAL (SEE LIGHTING FIXTURE SCHEDULE FOR LETTER EM - EMERGENCY Q DESIGNATION AND DESCRIPTION OF FIXTURES) 5) ALL CONDUIT AND WIRING SHALL BE CONCEALED IN WALLS OR ABOVE CEILINGS UNLESS NOTED 9* DUPLEX RECEPTACLE EMS - ENERGY MANAGEMENT SYSTEM OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. ALL DEVICE OUTLET BOXES SHALL BE EF - EXHAUST FAN RECESSED UNLESS NOTED OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. WHERE APPROVED GFI GROUND FAULT CIRCUIT INTERRUPTER OR NOTED SURFACE METAL RACEWAY AND DEVICE BOXES SHALL BE USED IN LIEU OF CONDUIT AND WP WEATHERPROOF EMERGENCY/NIGHT LIGHT LIGHTING FIXTURE EMT - ELECTRICAL METALLIC TUBING CONCEALED BOXES AT NO EXTRA COST TO THE OWNER. IG ISOLATED GROUND EWC - ELECTRIC WATER COOLER C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) ® ® EXIT LIGHTING FIXTURE UNIVERSAL MOUNT, SINGLE/DOUBLE FACE ETR - EXISTING TO REMAIN 6) ALL CONDUIT ROUTES SHOWN ARE APPROXIMATE ONLY. CONTRACTOR SHALL FIELD VERIFY FINAL ROUTE. EWC ELECTRIC WATER COOLER, COORDINATE LOCATION (WHERE USED, ARROW INDICATES CHEVRON DIRECTION) WITH PLUMBING CONTRACTOR EX - EXISTING 7) CONDUIT RUNS SHOWN ARE SCHEMATIC AND DO NOT INDICATE THE NECESSARY FITTINGS AND JUNCTION BATTERY POWERED EMERGENCY LIGHT BOXES THAT ARE INCLUDED IN THE SCOPE OF THE WORK. FA - FIRE ALARM Igh QUADRAPLEX RECEPTACLE EMERGENCY LIGHT REMOTE HEAD FAAP - FIRE ALARM ANNUNCIATOR PANEL 8) CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL WIRING WITH THE SOURCE AND CIRCUIT AT ALL ELECTRICAL EQUIPMENT, PULL AND JUNCTION BOXES AND ELECTRICAL TERMINATIONS PROVIDED OR GFI GROUND FAULT CIRCUIT INTERRUPTER I _� TRACK LIGHTING FACP - FIRE ALARM CONTROL PANEL ASSOCIATED WITH THIS CONSTRUCTION. WP WEATHERPROOF G - GROUND 9) CONTRACTOR SHALL PATCH AND REPAIR ALL DAMAGED SURFACES AND AREAS WHERE EQUIPMENT WAS IG ISOLATED GROUND O TRACK LIGHTING HEAD GFI - GROUND FAULT INTERRUPTER REMOVED OR MODIFIED, TO MATCH EXISTING CONDITIONS. C COUNTER HEIGHT (ABOVE COUNTER OR 42" AFF) WG WIRE CAGE LIGHT GUARD GND - GROUND 10) ALL ABANDONED AUDIO OR CONTROL CABLES SHALL BE REMOVED. ALL BOX OR EQUIPMENT OPENINGS GRC - GALVANIZED RIGID CONDUIT SHALL BE CLOSED WITH LISTED CLOSURE DEVICE AS APPROVED BY THE EQUIPMENT MANUFACTURER. Q * SPECIAL RECEPTACLE OS OCCUPANCY SENSOR -CEILING MOUNTED H.I.D. - HIGH INTENSITY DISCHARGE 11) WHERE EXISTING EQUIPMENT OR MATERIALS ARE REMOVED OR CHANGED, ALL BRANCH CONDUITS WHICH X TYPE X SEE RECEPTACLE SCHEDULE ( ) osC OCCUPANCY SENSOR - CEILING MOUNTED - CORRIDOR HVAC - HEATING, VENTILATING, AND AIR CONDITIONING NO LONGER ARE IN SERVICE, SHALL BE REMOVED AS DIRECTED BY THE ENGINEER. IF, IN THE COURSE C COUNTER HEIGHT OF THIS WORK, OUTLETS ARE COVERED UP OR OTHERWISE RENDERED INACCESSIBLE, ALL WIRING TO osW OCCUPANCY SENSOR - WALL MOUNTED I.G. - ISOLATED GROUND SAME SHALL BE REMOVED TO THE SOURCE. IF A CIRCUIT THAT MUST REMAIN IN SERVICE IS INTERRUPTED PP POWER POLE J - JUNCTION THEREBY, IT SHALL BE RECONNECTED BY THE MOST INCONSPICUOUS MEANS SO AS TO REMAIN LC LIGHTING CONTACTOR OPERATIONAL, WITH THE SAME CAPACITY AS BEFORE. ALL BUILDING SURFACES DAMAGED, AND OPENINGS ® RECESSED FLOOR MOUNTED DUPLEX RECEPTACLE KAIC - (THOUSAND) AMPERE INTERRUPTING CAPACITY LEFT BY REMOVAL OF BOXES, PIPING OR OTHER EQUIPMENT SHALL BE REPAIRED BY THE CONTRACTOR. PC PHOTOCELL KVA - KILOVOLT -AMPERES ALL HOLES LEFT IN JUNCTION BOXES, SWITCHES, PANELS, ETC. SHALL BE CLOSED. O SURFACE -MOUNTED FLOOR DUPLEX RECEPTACLE KW - KILOWATT 12) ALL REUSABLE DEVICES, FIXTURES AND EQUIPMENT SHALL BECOME THE PROPERTY OF THE OWNER. ALL OCEILING -MOUNTED DUPLEX RECEPTACLE S* SWITCH LTG - LIGHTING OTHER SALVAGE AND DEBRIS SHALL BE REMOVED FROM THE PREMISES DAILY. OS OCCUPANCY SENSOR SWITCH MCM - THOUSANDS OF CIRCULAR MILS 13) THIS CONTRACTOR SHALL FURNISH AND PROVIDE ALL DEMOLITION REQUIRED TO ACCOMMODATE THIS oho PLUG MOLD D DIMMER PROJECT WHETHER INDICATED ON DRAWINGS, OR DIRECTED IN THE FIELD. D3 THREE WAY DIMMER (INCANDESCENT) MCU - MASTER CONTROL UNIT C COUNTER HEIGHT MCP - MOTOR CIRCUIT PROTECTION GROUNDING: PJ JUNCTION BOX MH - METAL HALIDE 14) ALL METAL RACEWAYS, INCLUDING CONDUIT, WIRE TROUGHS, WIREMOLD, ETC., SHALL BE GROUNDED. ALL CONNECTIONS IN METAL RACEWAYS SHALL BE COMPLETED IN SUCH A MANNER AS TO MAINTAIN A EP DISCONNECT SWITCH TELECOMMUNICATIONS N - NEUTRAL CONTINUOUS PATH TO GROUND THROUGHOUT THE ENTIRE LENGTH OF THE RACEWAY. NA - NOT APPLICABLE EpWP DISCONNECT SWITCH - WEATHERPROOF (NEMA 3R) NF - NON-FUSED EXISTING DEVICES TO REMAIN: vDATA/COMM OUTLET FUSED DISCONNECT SWITCH NL - NIGHT LIGHT 15) UNLESS OTHERWISE NOTED: ® TELEVISION OUTLET NEC - NATIONAL ELECTRICAL CODE a. ON DEMOLITION AND NEW WORK PLANS - DEVICES AND EQUIPMENT SHOWN IN LIGHT LINETYPE ARE EXISTING TO REMAIN. MAGNETIC MOTOR STARTER SP SPEAKER NEMA - NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION b. ON DEMOLITION PLANS - DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE EXISTING TO BE REMOVED COMBINATION FUSED DISCONNECT/ NFPA - NATIONAL FIRE PROTECTION ASSOCIATION c. ON NEW WORK PLANS - DEVICES AND EQUIPMENT SHOWN IN DARK LINETYPE ARE NEW. * MAGNETIC STARTER SWITCH NIC - NOT IN CONTRACT O.C. - ON CENTER HOA HAND/OFF/AUTO SS START/STOP O.F.C.I. - OWNER FURNISHED CONTRACTOR INSTALLED ® M MANUAL STARTER P - POLE PNL - PANELBOARD VSD COMBINATION VARIABLE SPEED DRIVE AND DISCONNECT PVC - POLYVINYL CHLORIDE RGS - RIGID GALVANIZED STEEL vSDVARIABLE SPEED DRIVE RM - ROOM �/ . v EF -1 MOTOR WITH DESIGNATOR SPEC - SPECIFICATION TC TIME CLOCK SS - STAINLESS STEEL TVSS - TRANSIENT VOLTAGE SURGE SUPPRESSION WH WATER HEATER TYP - TYPICAL UON - UNLESS OTHERWISE NOTED HVPt-6 BRANCH CIRCUIT HOME RUN WITH PANEL NAME AND CIRCUIT NUMBER, � QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS V _ VOLTS W - WIRE BRANCH CIRCUIT WIRING, PROVIDE QUANTITIES OF CONDUCTORS REQUIRED FOR CIRCUITING AND SWITCHING INDICATED WP - WEATHERPROOF POWER LEG ONLY (NO SWITCH LEG BETWEEN ROOMS) ❑-3 MUSHROOM HEAD PUSH BUTTON (EMERGENCY STOP) RELAY 0-111, GROUND ROD MT TRANSFORMER FTIK TYPE "K" TRANSFORMER UH ELECTRIC UNIT HEATER (FURNISHED UNDER DIV 15 UNLESS NOTED OTHERWISE) �q ll 9Pr1io. 0 60 2 L m . NOTE: � STT SYMBOLS SHOWN ON THIS ELECTRICAL LEGEND ARE FOR I '�� F ., L REFERENCE PURPOSES ONLY. ALL OF THESE SYMBOLSy� MAY NOT BE USED FOR THIS PROJECT. `���� � ��E '6Ei 1, m 0 0 .Q U 0) m cl (D ro 0 m 0 U LL: R0000 ao � - a Nelson Blankenship, AIA P-4 C/) Q 0 a xE�44 U� om U r z� Cl� U U W I � Z Q' U '2 n DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER 1801 DRAWING NUMBER E-001 DATE 01-18-18 EXISTING PANEL'LA' LOCATION: MAIN SALOON VOLTAGE: 208Y/120V 30 TIN MIN. AIC RATING: EXISTING NOTES: PROVIDE TYPED WRITTEN DIRECTORY PROVIDE GROUND & NEUTRAL BUS TYPE: EXISTING MAINS: 200A ® MLO ❑ MCB MOUNTING: SURFACE FED FROM: EXISTING SERVICE LUGS: ❑ SUB -FEED ❑ FEED-THRU ENCLOSURE: NEMA 1 CIRCUIT DESCRIPTION o z BRANCH CIRCUIT BKR LOAD KVA PHASE 0 LOAD KVA BKR BRANCH CIRCUIT o z CIRCUIT DESCRIPTION 0 NEUT GND ICOND 0 NEUT GND ;GOND i RECEPTACLES - WORK AREA .___.._._...__......__........__.._ RECEPTACLES - WORK AREA EX I EX EX EX EX EX ? EX j EX 20/1 20/1 A B 0.550 0.50 20/1 20/1 EX EX EX EX EX EX EX EX y c UGHTING - 'WORK AREA ._.._.._........._.....3 LIGHTING OPEN AREA 2 4 5 RECEPTACLES - LOBBY EX EX EX ° EX 20f1 [0.72 C 1.00 20J1 EX EX EX EX 03 LIGHTING - MEZZA1dINE 6 7 RECEPTACLES - MEZZANINE EX ; EX EX EX 20/1 A 0.90 20/1 EX EX EX EX RECEPTACLES - WORK AREA (CEI) 8 9 RECEPTACLES - WINDOW EX ' EX EX EX 20/1 B 0.50 20/1 EX EX EX EX I JUGHI[ING - LOBBY 10 11 RECEPTACLE - HVAC (GFI) EX ; EX EX EX 20/1 0.18 C 4.550 50/3 EX EX EX EX IRrU #1 12 13 IRECEPTACLES - CONFERENCE ROOM EX EX EX EX 20/1 0.54 A 4.50 - EX _ _ _ 14 15 RECEPTACLES -REAR ROOM 12 12 12 e1/2" 20/1 1.00 B 4.50 EX - - - t& 17 RECEPTACLE -WORK AREA 12 12 12 1/2" 20/1 0.18 C 2,50 30/2 EX EX EX EX RiU 2 18 19 RECEPTACLES -MIDDLE ROOM & GFI 12 12 12 1/2" 20/1 0.54 A 2.50_ EX - - 20 HOTWATER HEATER SPACE ONLY 12 12 _ 12 1/2" 20/1 1.44 - B C 0.50 - 20/1 - EX - - - - - LIGHTING - WAITING ROOM SPACE ONLY 22 24 h2lINSTA ONLY- _SPACE A - - SPACE ONLY 26 SPACE ONLY - - - - B - SPACE ONLY 28 29 SPACE ONLY - - - I - _ - C - - - SPACE ONLY 30 EQUIPMENTSERVED CONN. LOAD L.F. D.F. DEMAND LOAD _..._........_....._....._..___._._.._____ EXISTING LOAD 26.18 KVA RECEPTACLES - GENERAL 1.72 KVA 1009 100% _.._...._. _.. 26.18 KVA 1.72 KVA EQUIPMENT 1.44 KVA 100% 1.44 KVA NOTES: 1)EXISTING CIRCUIT TO BECOME SPARE TOTAL DEMAND LOAD: 29.34 KVA TOTAL DEMAND AMPS: 81.50 AMPS First Floor Renovation Plan - Electrical SCALE: 1/4"=1'-0" GENERAL NOTES: A. DO NOT SCALE ELECTRICAL DRAWING FOR ANY DIMENSIONS. B. ALL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE, NATIONAL, STATE AND LOCAL CODES. PROVIDE GROUNDING AND BONDING PER NEC 250. C. FIELD VERIFY EXACT LOCATION OF ALL DEVICES AND EQUIPMENT PRIOR TO ROUGH IN. REFERENCE NOTES: O O EXISTING RECEPTACLES AND DATA OUTLETS TO REMAIN. SCOPE OF WORK: THIS PROJECT IS THE MODIFICATION OF AN EXISTING OFFICE SPACE INTO A BEAUTY SALON. ALL NORMAL AND EMERGENCY LIGHTING ON THE FIRST FLOOR ARE EXISTING TO REMAIN. SECOND FLOOR MEZZANINE IS NOT INCLUDED IN THE SCOPE OF WORK AND ALL ELECTRICAL SHALL BE EXISTING TO REMAIN. r T m O .Q U a� m ro 0 0 U y c a W J = 3Fmo Q, O �U 0 Nelson Blankenship, AIA �.r - a w� - z ¢z< Q2 03 o U � � o DRAWN CHECKED MJR/KCM BLS/AJB PROJECT NUMBER L801 DRAWING NUMBER E-201 DATE 01-18-1s