HomeMy WebLinkAbout1602 W Airport Blvd 17-3695 Plans111E ♦♦[11<L11Vvvu
SUITE 1602
LOCATION PLAN
LOCATION MAP
t
41
^"
;W'0
:n r>•�,� I leh S: �11
E
INTERIOR BUILDOUT
THE WAREHOUSE
1602 W. AIRPORT BLVD.
SANFORD, FL 32773
LEGAL DESCRIPTION
SEC 02 TWP 20S RGE 30E
N 666.6 FT OF W 623.97 FT OF NW 14
(LESS N 280 FT OF W 240 FT & RDS)
BUILDING CODE INFORMATION
ADOPTED CODES
BUILDING: 2014 FLORIDA BUILDING CODE, BUILDING
(W/ LOCAL ADOPTED AMENDMENTS)
2014 FLORIDA BUILDING CODE, EXISTING
BUILDING
FIRE: 2014 FLORIDA FIRE PREVENTION CODE
(5 EDITION)
PLUMBING: 2014 FLORIDA BUILDING CODE
MECHANICAL: 2014 FLORIDA MECHANICAL CODE
ELECTRICAL: 2011 NATIONAL ELECTRICAL CODES
FUEUGAS: 2014 FLORIDA FUEL/GASBCODE
ACCESSIBILITY: 2014 -FLORIDA ACCESSIBILITY CODE
ENERGY: 2014 FLORIDA ENERGY CODE
BUILDING AND CONSTRUCTION DATA
SHEET
OCCUPANCY CLASSIFICATION (FBC 301) MERCANTILE - GROUP M
CONSTRUCTION TYPE (FBC TABLE 601) TYPE
II -B, WITHOUT EXISTING FIRE SPRINKLER SYSTEM
TOTAL OCCUPANT LOAD = 62 PERSONS
C-01
FIRE RESISTANCE
I OF8 112817
MATERIALS/CONSTRUCTION (FBC 704.4)
LIFE SAFETY PLAN
SINGLE OCCUPANCY BUILDINGS
TENANTS SEPARATED BY 1 -HOUR
MINIMUM FIRE RESISTANCE, FBC TABLE 705.1.2
3 OF 8 112817
A-2.1
WALLS OPENINGS
FIRE WALLS
4 3
TENANT SPACE
1 3/4
HORIZONTAL EXIT
2 11/2
INTERIOR FINISHES, FBC 803
CLASSIFICATION, FBC 803.2
OCCUPANCY(ASSEMBLEY)
WITH EXISTING SPRINKLER), TABLE 803.5
OCCUPANCY SEPARATION REQUIREMENT:
CLASSIFICATION OF WORK
CHANGE OF USE
AREA TABULATION
TOTAL AREA = 3,715 SF
PLUMBING REQUIREMENT
TWO TOILET REQUIRED PER 500 OCCUPANTS
OCCUPANT LOAD = 62 PERSONS
REQUIRED 2 TOILETS
PROVIDED 2 TOILETS = OK
PROJECT SPECIFIC NOTES
1.) TENANT OR TENANTS CONTRACTOR MUST OBTAIN LANDLORDS
APPROVAL FOR ANY STRUCTURAL WORK WITH THE SPACE.
2.) CONTRACTOR SHALL NOT USE SHOPPING CENTER DUMPSTERS FOR
ANY DISPOSAL OF THEIR CONSTRUCTION MATERIAL. ALL DEBRIS,
MATERIAL ETC. SHALL BE REMOVED FROM THE SITE DAILY.
3.) ALL SLAB REMOVAL MUST BE REPLACED WITH 4" THICK
CONCRETE SLAB REINFORCED WITH W.W.F. (OR FIBERMESH) ON 10
MIL VAPOR BARRIER. ALL CONCRETE SLABS SHALL HAVE A
COMPRESSIVE STRENGTH OF NOT LESS THAN 3,000 PSI @ 28 DAYS.
PROJECT TEAM:
A-FLAMESPREAD 0-25, SMOKE DEV. 0-450
B-FLAMESPREAD 26-75, SMOKE DEV. 0-450
C-FLAMESPREAD 76-200, SMOKE DEV. 0-450
EXITS - CLASS C
ACCESS - CLASS C
OTHER SPACES - CLASS C
SHALL BE 1 HOUR FIRE RESISTANT
OWNER:
THE WAREHOUSE
1602 W. AIRPORT BLVD.
SANFORD, FL 32773
CONTRACTOR:
TBD
ENGINEER
KL ENGINEERING
KHANH Q. LE, PE FLORIDA LICENSE NO. 70935
427 PALM CREST LANE
LAKE MARY, FL 32746
PHONE: (407) 361-8017 FAX: (407) 610-5695
DESIGNER
GREENLEAF DESIGN SERVICES, INC.
1311 W. MARVIN ST.
LONGWOOD, FL 32750
PHONE:407-462-4489
NOTE TO BUILDING DEPARTMENT:
PURPOSE OF THESE PLANS IS TO SPECIFY
EXISTING TENANT SPACE BUILDOUT AND
CHANGE OF USE.
MINOR MODIFICATIONS TO EXISTING FLOOR,
ELECTRICAL AND PLUMBING ARE INDICATED ON
THESE PLANS. THERE IS NO HVAC WORK AT THIS
TIME.
CONTACT KL ENGINEERING FOR QUESTIONS OR
CLARIFICATIONS NEEDED DURING PLAN REVIEW
OR DURING CONSTRUCTION.
PERMIT 9
SANFORD BUILDING DIVISION
A PERMIT ISSUED SHALL BE CONSTRUED TO BE A
LICENSE TO PROCEED WITH THE WORK AND NOT AS
AUTHORITY TO VIOLATE. CANCEL, ALTER OR SET
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING A CORRECTION OF ERRORS IN PLANS.
CONSTRUCTION OR VICLATiONS OF THIS CODE
KL ENGINEERING
Khanh Q. Le. PE
Florida License No. 70935
427 Palm Crest Lane
Lake Mary, FI 32746
Phone (407)361-8017
Fax (407) 610-5695
To the best of the knowledge of the Engineer or Architect
the plans and specifications herein comply with the 2014
Florida building code and are Signed and Sealed accordingly
®FF'C'
201700081
SHEET
INDEX
DWG. #
TITLE
DATE
SIIEET # ISSUED DATE REVS.
C-01
COVERSHEET
I OF8 112817
LS -1.0
LIFE SAFETY PLAN
2 OF 8 112817
A-2.0
EXISTING AND PROPOSED FLOOR PLANS
3 OF 8 112817
A-2.1
ENLARGED BATHROOM PLAN AND DETAILS
4 OF 8 11.'2817
M-1.0
HVAC PLAN
5 OF 8 11,28,17
E-1.0
ELECTRICAL PLAN
6 OF 8 1128,17
E-I.I
REFLECTED CEILING PLAN
7 OF 8 112817
P-1.0
PLUMBING PLAN AND ISOMETRICS
8 OF 8 11 28 17
NOTE TO BUILDING DEPARTMENT:
PURPOSE OF THESE PLANS IS TO SPECIFY
EXISTING TENANT SPACE BUILDOUT AND
CHANGE OF USE.
MINOR MODIFICATIONS TO EXISTING FLOOR,
ELECTRICAL AND PLUMBING ARE INDICATED ON
THESE PLANS. THERE IS NO HVAC WORK AT THIS
TIME.
CONTACT KL ENGINEERING FOR QUESTIONS OR
CLARIFICATIONS NEEDED DURING PLAN REVIEW
OR DURING CONSTRUCTION.
PERMIT 9
SANFORD BUILDING DIVISION
A PERMIT ISSUED SHALL BE CONSTRUED TO BE A
LICENSE TO PROCEED WITH THE WORK AND NOT AS
AUTHORITY TO VIOLATE. CANCEL, ALTER OR SET
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING A CORRECTION OF ERRORS IN PLANS.
CONSTRUCTION OR VICLATiONS OF THIS CODE
KL ENGINEERING
Khanh Q. Le. PE
Florida License No. 70935
427 Palm Crest Lane
Lake Mary, FI 32746
Phone (407)361-8017
Fax (407) 610-5695
To the best of the knowledge of the Engineer or Architect
the plans and specifications herein comply with the 2014
Florida building code and are Signed and Sealed accordingly
®FF'C'
201700081
g, ;
m!, M
f4%
w
Q
W
W
O
m
N
H
W
O
w
0.
3
w
¢
3
o
ti
O
U
g, ;
m!, M
f4%
SIGN & SEAL
'jH I IQIU
* N 935
STATE OF t4�
i O••
ij7j/QNAL;\`���N
W
W
w
H
H
W
w
U
SIGN & SEAL
'jH I IQIU
* N 935
STATE OF t4�
i O••
ij7j/QNAL;\`���N
WALL LEGEND:
® SOUND INSULATED WALL
LOAD BEARING WALL 4'
SOUND INSULATED PLUMBING WALL 6'
® LOAD BEARING WALL 6'
o STUD WALL—NON—LOAD BEARING 4'
LOAD BEARING INSULATED PLUMBING WALL 6"
® STUD WALL—NON—LOAD BEARING 8"
LIFE SAFETY SYMBOLS LEGEND
DESIGN CRITERIA
CODES AND EDITIONS USED: FLORIDA BUILDING CODE 2014, BUILDING.
(W/ LOCAL ADOPTED AMENDMENTS)
FLORIDA BUILDING CODE 2014 EXISTING BUILDING.
NATIONAL ELECTRICAL CODE 2011
LIFE SAFETY CODE, NFPA 101, 2012 ED.
FLORIDA FIRE PREVENTION CODE 2014
OCCUPANCY CLASSIFICATION:
GROUP M - MERCANTILE (309 FBC)
EXISTING TENANT SPACE IS NOT FIRE SPRINKLERED
CONSTRUCTION TYPE: TENANT SPACES: TYPE IIB (602.2 FBC)
GENERAL BUILDING LIMITATIONS:
BUSINESS
ALLOWED PROVIDED
NO. STORIES III I
AREA 23,000 3,715 SF
PER FLOOR
OCCUPANT LOAD: SR
CAPACITY OF EXIT STAIR: N/A (1005.1 FBC)
ARRANGEMENTS AND NUMBER OF EXITS:
MAXIMUM TRAVEL DISTANCE TO EXIT: (T1016.2 FBC)
ALLOWED PROVIDED
200' 121'-10"
MAXIMUM DEAD END CORRIDOR LENGTH: (1018.4 FBC)
ALLOWED PROVIDED
20' N/A
MINIMUM CORRIDOR WIDTH: (1018.2 FBC):
ALLOWED PROVIDED
44' N/A
MINIMUM EXIT AND MEANS OF EGRESS WIDTH: (1021.1 FBC)
MINIMUM EXITS REQUIRED:
REQUIRED PROVIDED
2 4
MINIMUM WIDTH FOR EA. EXIT DOOR: (1008.1.1 FBC)
REQUIRED PROVIDED
32 (CLEAR) 36
MINIMUM STAIR WIDTH: (1009.1 FBC) (NOT A PATH FOR EGRESS)
36" N/A
MIN EXIT SEPARATION (EQUAL TO NOT LESS THAN
1/2 BUILDING DIAGONAL - 1015.2.1 FBC)
ALLOWED PROVIDED
49'-3" 86'-7"
OCCUPANT LOAD CALCULATIONS
ACTUAL OCCUPANT LOAD
5k�__
EGRESS CAPACITY
X
TRAVEL DISTANCE
XXX
EXIT ACCESS TRAVEL DISTANCE ALLOWED
— — —
PATH OF TRAVEL
®
EMERGENCY EXIT LIGHT
EMERGENCY EGRESS LIGHT W/ BATTERY BACK-UP -
6
WALL MOUNTED FIRE EXTINGUISHER
FE
W/ BRACKET AND STRAP
O
SMOKE DETECTOR W/ ALARM
®
1 HOUR FIRE RATED
2
EXISTING STEEL COLUMNS TO REMAIN
DESIGN CRITERIA
CODES AND EDITIONS USED: FLORIDA BUILDING CODE 2014, BUILDING.
(W/ LOCAL ADOPTED AMENDMENTS)
FLORIDA BUILDING CODE 2014 EXISTING BUILDING.
NATIONAL ELECTRICAL CODE 2011
LIFE SAFETY CODE, NFPA 101, 2012 ED.
FLORIDA FIRE PREVENTION CODE 2014
OCCUPANCY CLASSIFICATION:
GROUP M - MERCANTILE (309 FBC)
EXISTING TENANT SPACE IS NOT FIRE SPRINKLERED
CONSTRUCTION TYPE: TENANT SPACES: TYPE IIB (602.2 FBC)
GENERAL BUILDING LIMITATIONS:
BUSINESS
ALLOWED PROVIDED
NO. STORIES III I
AREA 23,000 3,715 SF
PER FLOOR
OCCUPANT LOAD: SR
CAPACITY OF EXIT STAIR: N/A (1005.1 FBC)
ARRANGEMENTS AND NUMBER OF EXITS:
MAXIMUM TRAVEL DISTANCE TO EXIT: (T1016.2 FBC)
ALLOWED PROVIDED
200' 121'-10"
MAXIMUM DEAD END CORRIDOR LENGTH: (1018.4 FBC)
ALLOWED PROVIDED
20' N/A
MINIMUM CORRIDOR WIDTH: (1018.2 FBC):
ALLOWED PROVIDED
44' N/A
MINIMUM EXIT AND MEANS OF EGRESS WIDTH: (1021.1 FBC)
MINIMUM EXITS REQUIRED:
REQUIRED PROVIDED
2 4
MINIMUM WIDTH FOR EA. EXIT DOOR: (1008.1.1 FBC)
REQUIRED PROVIDED
32 (CLEAR) 36
MINIMUM STAIR WIDTH: (1009.1 FBC) (NOT A PATH FOR EGRESS)
36" N/A
MIN EXIT SEPARATION (EQUAL TO NOT LESS THAN
1/2 BUILDING DIAGONAL - 1015.2.1 FBC)
ALLOWED PROVIDED
49'-3" 86'-7"
OCCUPANT LOAD CALCULATIONS
NFPA 101-7.3.1.2 & FBC TABLE 1004.1.2.
SPACE
LOAD FACTOR
AREA
OCC LOAD
MERCANTILE
60 SF/PERS GROSS
3715 S.F.
62 PERSONS
TOTALS
62 PERSONS
GENERAL NOTES
I. BUILDING EXIT DOORS WILL SWING IN THE DIRECTICN
OF EGFESS TRAVEL.
2. ALL AREAS 1 MaJIRED ROOMS WILL i3E EQUIPPED
WITH EMEWiENCY L*14$ G.
3. FIRE EXTMGUISNERS WILL BE PLACED AT ]INTERVALS
NOT TO EXCEED A TRAVEL DISTANCE OF 15'.
EMERGENCY LIGHTING NOTE;
PLEASE SEE ELECTRICAL DRAWING8
FOR EMERGENCY LIGHTING INFORMATION
MUST BE IN ACCORDANCE WITH NFPA 10
N
4'
MAX.
v
FEC FE
FIRE EXTINGUISHER CARNET FIRE EXTINGUISHER -WALL ITING
FIRE EXTINGUISHER
MOUNTING HEIGHTS
EXISTMCa I HO
OL 0465
TFN
45 121'-10
180 200 -0
17
180
LIFE SAFETY PLAN
SCALE: 1/4" = 1-0"
'ro the best of the knowledge of the Engineer or Archilrct
the plans and specifications herein comply with the 2014
Florida building code and are Signed and Sealed accordingly.
KL ENGINEIItING
Khanh Q. Le, PE
Florida License No. 70935
427 Palm Crest Lane
Luke N1ary,Ft32746
Phone(407)361-8017
Fax (407) 610-5695
mmmmmo
DRAWING NUMBER
201700081
SIGT
& SEAL
;ENR''
,70935
\TE OF �
11111\\\\
DO O R SC BEDUIE
MARK
RO0 M FINISH SCHEDUIE
LEG IND:
SC: SERI- D CONCREIE
GW& GYPSUM WAIiBOARD
EP: EPO XY ED: FID 0 R DRAIN
C P CERAMIC DIE
MR MOISIURERES�I1iNT
OOD
CP COMM RCIALC RPE
CPL COMMIRCIALCARPET
ACP ACOLlSI]CALIl[E
CT CERAMIC TLE
IF LAMINATE
MARK ARCA FIDOR BASE WAILS CN11NG HE[Gl NOTES
101 FURNII ARFA EXISE EM ESP EXIST EXEr
102 JANIIO R EXUP EX]S'r E?ffS>: ESP E or
103 SUPPLY C L O SEP EX15P EXET EXIST' EXIST EXIST
104 &AIIIROOVI#1 EPSP VB PAIIV77GNVB YAIINDGWB F1�SP SLENO'IE#1
105 BATHROOM#2 EXISP VB PAINDGWB PAIN'DGWB EXIST SEENO'IE#1
106 CID IHNG AREA ISP FISP EP EPSP FSP
107 EIFICTROINICS/ BOOFSARFA EX6T EXIST EY1SP EYLSP EXIST
THRESHOLDS, DOOR BOTTOMS,
A
1
WD
WD
NOTE %
1. WARS AND PARIIMNS WIlIIN 2 FP 0 F SMVIC E SINIT; URINAIS AND
WATER C ID SEIS SHALL C O MPLY W/ FBC 1210.2.2.
DO O R SC BEDUIE
MARK
SIZE
DETAILS
ELEV
HARDWARE
MA'IIItTAL
REvIARM
DOOR
FRAME
101A
3068
THRESHOLDS, DOOR BOTTOMS,
A
1
WD
WD
hPR EACH HAG HINGES
WALL LEGEND:
® 8" EXIST. CMU WALL.
Q® PLUMBING WALL
PROPOSED WALLS
EXISTING WALLS
EXISTING FLOOR PLAN
SCALE: 3/16" = 1-0"
a'IGNAG E REQ UIIZiMIIV'IS:
SIGNAGEREQUMED ATAILROOMSINDICN11NG ROOM NAMES
AND NUMHTS.
SIGNAGEREQU1RFD 1NDICATNG AILHC ACCESSMEARFAS
GENERALDOORNMER
1. DOOR HARDWAREREIQUIRID TO BEACCESSIBIEPERFBC CH 11
SHALLNOTREQUIREMHFGRASPING, TIGHrPNCHNG OR
TIVISIING OFTE EWRISTTO OPERATE
2. DFADBOLTSAREPROHIBIIFD ON EGRESS DOORS PER FBC
1008.1.9.4.
3. DOORSAND LOCK3SHALLMEErALLREQUllRE'VIWISOF2014
FIDRIDAACCESSMEnYCODEFORBUIIDNG CONSIRUC'LION.
EXIST. 3068
NEV MOP SINK T
L'12'
0L UTILIZE EXI8TMG
JANITOR 01 81PPLY /
EXISTING A WASTEIIWTERLMS
CEILING
103
'PLY CLOSET(T
EXISTING
CEILING /
/104
B�THROOM #11 A /
j// C DISPLAY RACK TTP.
HARDWARE
SCHEDULE
NOTE: PROVIDE RATED 1 LABELED HARDWnRE DOORS 1 FRAMES IN
ALL RATED LOCATIONS
BASED CN:
HINGES - HAGER
STOPS, FUSH PULLS,
LOCKS - SCNLAGE 'D' SERIES
KICKPLATES - IVES, RCCKIUOOD
CLOSERS - LCN
THRESHOLDS, DOOR BOTTOMS,
EXIT DEVICES - VON PUPRIN
SEALS - PE11KO
HARDWARE SET 9 -
hPR EACH HAG HINGES
1191 45 x 45 U532D
I EACH SCH STOREROOM
D80PD SPARTA U526D
I EACH ROC STOP
409 US32D
NOTE: ALL HARDWARE SETS BASED ON SINGLE LEAF DOOR. PROVIDE TWO SETS AS
REQUIRED AND ALL ADDITIONAL. HARDWARE AS NEEDED FOR ALL DOUBLE LEAF DOOR
LOCATIONS.
NOTE: FINAL FINISH ON ALL ITEMS IS TO MATCH FOR COLOR RANGE AND FINISH.
NOTES:
I. THIS HARDWARE 604EDULE IS FOR REFERENCE ONLY. CONTRACTOR IS TO PROVIDE
HARDWARE CONSULTANT TO WORK WITH OI NER FOR COMPLETE HARDWARE PACKAGE UPON
AWARD OF CONTRACT 1 PRIOR TO ORDERING DOORS, FRAMES OR HARDWARE.
2. USE 851191 • ALL DOORS WITH CLOSERS
3. USE NRP ON ALL EXTERIOR HWzES
4. KICKPLATES ARE TO BE 8' x 2' LESS THAN DOOR WIDTH
8'-10'
ADA - COUNTER ELEVATION
\ 107
DESIGNATED
ELEC'IRO NIC S /
\BOE ARFA ADA 51GN COMPLIANCE FOR
1
01 \GGSI / ACGE5515LE TOILET ROOM
BkTHROOM #3/ OA CE /
/ >
I'-4" ® cn
---------\ e n
r
MST. in
�p y�
+ l06 \
DESIGNArRD \ ,�
�LooR
C IO T-ING ARFA CLOT1414 RACK
1OS11vG TYP \ H O
GT]IING 2 ADA SIGN ON BATHROOM DOOR
I I I \
RETAIL SPAC E
GLASS DISPLAY
ADA COUNTER
I I
101
DESIGNA'HD RT IIUREARFA
EX]S11NG
CUING
L- - - - - - - - - - - - - - - - - - - - -
EXIST. 3068 EKIST, 3068
EXIST. STOFEfRLNT EXIST. STOUT DIST. STORcFTdTlT
PROPOSED FLOOR PLAN
SCALE: 3/16" = 1-0"
(
I
I
I
I
I
I
I
I
I
I
--J
EMT. STOFSf4W
'ro the best of the knowledge of the Engineer or Architect
the plans and specifications herein comply with the 2014
Florida building code and are Signed and Sealed accordingly.
n ENGINEERING
Khanh Q. Le, PE
Florida License No. 70935
427 Palm Crest Lame
Lake Mary, F132746
Phase (407)36t-8017
Fax (407) 6105695
DRAWING NUMBER
201700081
� L
SIGN & SEAL l
,44
FIXTURE SCHEDULE
LEGEND
WC
WATER CLOSET
SO
MARK FIXTURE MANUFACTURER
MODEL NUMBER
MATERIAL
MOUNTING
REMARKS
WC1 WATER CLOSET AMERICAN STANDARD
HC -3043.102.020
VITREOUS CHINA
FLOOR
ADA
LAV 1 WALL HUNG SINK AMERICAN STANDARD
00355.012
VITREOUS CHINA
WALL
SENSOR FAUCET
FD FLOOR DRAIN
ZURN #Z-1400
STANDARD PVC
TOWEL BAR
-
DF1 HI -LO DRINKING FOUNT. LK
EZSTL2
ADA
WH1 WATER HEATER
40 GAL
SINK SINK DAYTON
23322
COUNTER
A.S. 4275.550 FAUCET
MS MOP SINK FIAT
MSB2424
NOTES: PROVIDE SEAT FOR ALL TOILETS- BEMIS 1955C
TOILETS - 1.6 GAL PER FLUSH
SENSOR FAUCETS AT LAVS: SLOAN SF2150-4 W/ MIX 60A TEMPERING VALVE
FIXTURES AS NOTED OR APPROVED EQUAL
ALTERNATE FINISHES OR EQUAL MATERIALS ARE POSSIBLE WITH OWNER/ENGINEER WRITTEN APPROVAL.
METAL CLIP
3-5/8' 25 GA.
TRACK
Q
�7
Lu
z
Lu
0
4' 25 GA.
BOTTOM TRACK
0
U
F1
C.
4' x 25 GA. MTL. DIAG. FRM'G AT 48'
O.C. ATTACHED TO STRUCTURE ABOVE
2'X4' CEILING TILE
NOTES:
I. USE *1X7/16' PAN HEAD TYPE 'S'
FRAMING SCREW FOR STEEL STUD
TO STEEL TRACT.
2. USE "6XI-1/4' TYPE 'S' DRYWALL
SCREWS TO STEEL FRAMING.
3. METAL MEMBERS TO BE I ACCORDANCE
WITH THE AI51 SPECIFICATIONS FOR THE
DESIGN OF COLD FORMED STRUCTURED
MEMBER, LATEST EDITION.
4. METAL MEMBERS TO BE IN ACCORDANCE
WITH ASTM C645 STANDARD SPECIFICATIONS
FOR NONSTRUCTURAL STEEL FRAMING
MEMBERS 2000
1/2' GYPSUM BOARD
4' METAL STUD 25 GAGE 24' O.C. COVER BOTH SIDES
WITH 1/2 GYPSUM BOARDS PAINTED, VERIFY COLOR W/
OWNER WALLS ARE LATERALLY SUPPORTED BY
INTERSECTING WALLS
3/1&'X 1-1/4' MASONRY SCREWS
OR POWDER ACTUATED SCREWS
la' O.G.
CONC.SLAB
I TYP. NON BEARINCx INTERIOR PARTITION WALL.
FNISI-ED FNISHED
SURI=ACE SUIRFACE
OF WALL 36' OF WALL
2 1/4' 36' X12' Ok 42'
IS' �
GB
DISPENSE
RH OPENIM
El
i4 Qr iLi9
r U1G
WC -WATER CLOSET RH -TOILET ROLL HOLDER
GB -GRAB BAR
50
LAY
. r �i
.
TD -PAPER TOWEL DISPENSER
LAY -LAVATORY
TYPICAL HANDICAPPED ACCESSIBLE DETAILS
O
9
� z c
v
MAv Mu
COMBO DRINKING FOUNTAINS
M -MIRROR
SD -SOAP DISPENSER
ENLARGED BATHROOM 102-105
SCALE: 112" = 1-0'
ACCESSIBILITY NOTES: ADA/ ANSI A117.1/ FACBC.
1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED AT ALL ACCESSIBLE
RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES UNLESS ALL ENTRANCES ARE ACCESSIBLE.
INACCESSIBLE ENTRANCES SHALL HAVE DIRECTIONAL SIGNS INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE.
2. WHERE STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS AND DRAWERS ARE PROVIDED AT LEAST ONE OF EACH
TYPE PROVIDED SHALL CONTAIN STORAGE SPACE COMPLYING WITH THE FOLLOWING: DOORS ETC. TO SUCH SPACES SHALL
BE ACCESSIBLE (ie. TOUCH LATCHES, U -SHAPED PULLS); SPACES SHALL BE WITHIN 15 INCHES MINIMUM AND 48 INCHES
MAXIMUM OF THE FLOOR FOR FORWARD REACH OR 9 INCHES MINIMUM AND 54 INCHES MAXIMUM, OF THE FLOOR FOR SIDE
REACH; CLOTHES RODS SHALL BE A MAXIMUM OF 54 INCHES ABOVE THE FLOOR ( 48 INCHES MAXIMUM WHEN DISTANCE FROM
WHEELCHAIR TO ROD EXCEEDS 10 INCHES ).
3. CONTROLS, DISPENSERS, RECEPTICLES AND OTHER OPERABLE EQUIPMENT SHALL BE NO HIGHER THAN 45 INCHES ABOVE THE
FLOOR FOR SIDE APPROACH. RECEPTICLES ON WALLS SHALL BE MOUNTED NO LESS THAN 15 INCHES ABOVE THE FLOOR.
EXCEPTION: HEIGHT LIMITATIONS DO NOT APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE
ELECTRICAL RECEPTICLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS.
4. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS.
THE VISUAL ALARMS SHALL BE LOCATED THROUGHOUT, INCLUDING RESTROOMS, AND PLACED 80 INCHES ABOVE THE FLOOR
OR 6 INCHES BELOW CEILING, WHICHEVER IS GREATER.
5. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE (ie. LEVER OPERATED, PUS -TYPE, U -SHAPED )
MOUNTED NO HIGHER THAN 48 INCHES ABOVE THE FLOOR.
6. FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP - RESISTANT. CHANGES IN LEVEL BETWEEN 0.25 INCH AND 0.5 INCH
SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2, CHANGES IN LEVEL GREATER THAN 0.5 INCH REQUIRE RAMPS.
CARPET PILE THICKNESS SHALL BE 0.5 INCH MAX. GRATINGS IN FLOORS SHALL HAVE NO SPACE GREATER THAN 0.5 INCH
WIDE IN ONE DIRECTION. DOORWAY THRESHOLDS SHALL NOT EXCEED 0.5 INCH IN HEIGHT,
7. ALL DOORS SHALL BE OPENABLE BY A SINGLE EFFORT. THE MAXIMUM FORCE REQUIRED TO OPEN A DOOR SHALL NOT
EXCEED 8.5 LBS. FOR EXTERIOR SWINGING DOORS AND 5 LBS. FOR ALL SLIDING, FOLDING AND INTERIOR SWINGING DOORS.
8. ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL HUNG WITH ELONGATED RIMS AT A MAXIMUM OF 17 INCHES ABOVE THE
FLOOR.
9. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE
OF AT LEAST 29 INCHES ABOVE THE FLOOR TO THE BOTTOM OF APRON.
10. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE
OF AT LEAST 27 INCHES HIGH, 30 INCHES WIDE, AND 19 INCITES DEEP UNDERNEATH SINK. THE SINK DEPTH SHALL BE 6.5 INCHES
MAXIMUM.
11. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED
TO PROTECT AGAINST CONTACT. INSULATION OR PROTECTION MATERIALS MAY BE SITE INSTALLED. THERE SHALL BE NO SHARP
OR ABRASIVE SURFACES UNDER ACCESSIBLE LAVATORIES AND SINKS.
12. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS ( ie. LEVER -OPERATED, PUSH -TYPE, ELECTRONICALLY
CONTROLLED ).
13. WHERE MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE SHALL BE LOCATED WITH A USEABLE SHELF NO HIGHER THAN
44 INCHES ABOVE THE FLOOR.
14. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.25 TO 1.5 INCHES IN DIAMETER WITH 1.5 INCHES OF CLEAR SPACE
BETWEEN THE BAR AND THE WALL.
15. A TOWEL DISPENSER SHALL BE LOCATED NEXT TO ALL ACCESSIBLE LAVATORIES
20 GAGE 6' GALV.
METAL STUDS
USE 10 X 3/4'
DRILLING SMS
AS 51-
20 GAGE E
METAL
USE 'O X 3/4' SELF DRILLING
SMS AS SHOWN FOR STEEL—-
STUD
TEELSTUD TO STEEL TRACK TYP.
20 GAGE 6' GALV. METAL
STUDS 16' O.C. COVER 50TH
SIDES WITH 5/8' GYPSUM
50ARDS PAINTED, VERIFY
COLOR W/ OWNER
20 GAGE 6' GALV.
METAL TRACK
USE h0 X 3/4'
SELF DRILLING
SMS TYP. AS
SHOWN
20 GAGE 6' GALV.
NDR STUDS
SECTION: 88
DETAIL A:
JAMS DETAIL
r
LEGEND
WC
WATER CLOSET
SO
SOAP DISPENSER
TDD
TOWEL DISPENSER/DISPOSAL
RH
TOILET ROLL HOLDER
FD
FLOOR DRAIN
GB
GRAB BAR
LAV
LAVATORY
HD
ELEC. HAND DRYER
UR
URINAL
MIR
MIRROR
TB
TOWEL BAR
SH
SHOWER
ENLARGED BATHROOM 102-105
SCALE: 112" = 1-0'
ACCESSIBILITY NOTES: ADA/ ANSI A117.1/ FACBC.
1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED AT ALL ACCESSIBLE
RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES UNLESS ALL ENTRANCES ARE ACCESSIBLE.
INACCESSIBLE ENTRANCES SHALL HAVE DIRECTIONAL SIGNS INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE.
2. WHERE STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS AND DRAWERS ARE PROVIDED AT LEAST ONE OF EACH
TYPE PROVIDED SHALL CONTAIN STORAGE SPACE COMPLYING WITH THE FOLLOWING: DOORS ETC. TO SUCH SPACES SHALL
BE ACCESSIBLE (ie. TOUCH LATCHES, U -SHAPED PULLS); SPACES SHALL BE WITHIN 15 INCHES MINIMUM AND 48 INCHES
MAXIMUM OF THE FLOOR FOR FORWARD REACH OR 9 INCHES MINIMUM AND 54 INCHES MAXIMUM, OF THE FLOOR FOR SIDE
REACH; CLOTHES RODS SHALL BE A MAXIMUM OF 54 INCHES ABOVE THE FLOOR ( 48 INCHES MAXIMUM WHEN DISTANCE FROM
WHEELCHAIR TO ROD EXCEEDS 10 INCHES ).
3. CONTROLS, DISPENSERS, RECEPTICLES AND OTHER OPERABLE EQUIPMENT SHALL BE NO HIGHER THAN 45 INCHES ABOVE THE
FLOOR FOR SIDE APPROACH. RECEPTICLES ON WALLS SHALL BE MOUNTED NO LESS THAN 15 INCHES ABOVE THE FLOOR.
EXCEPTION: HEIGHT LIMITATIONS DO NOT APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE
ELECTRICAL RECEPTICLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS.
4. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS.
THE VISUAL ALARMS SHALL BE LOCATED THROUGHOUT, INCLUDING RESTROOMS, AND PLACED 80 INCHES ABOVE THE FLOOR
OR 6 INCHES BELOW CEILING, WHICHEVER IS GREATER.
5. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE (ie. LEVER OPERATED, PUS -TYPE, U -SHAPED )
MOUNTED NO HIGHER THAN 48 INCHES ABOVE THE FLOOR.
6. FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP - RESISTANT. CHANGES IN LEVEL BETWEEN 0.25 INCH AND 0.5 INCH
SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2, CHANGES IN LEVEL GREATER THAN 0.5 INCH REQUIRE RAMPS.
CARPET PILE THICKNESS SHALL BE 0.5 INCH MAX. GRATINGS IN FLOORS SHALL HAVE NO SPACE GREATER THAN 0.5 INCH
WIDE IN ONE DIRECTION. DOORWAY THRESHOLDS SHALL NOT EXCEED 0.5 INCH IN HEIGHT,
7. ALL DOORS SHALL BE OPENABLE BY A SINGLE EFFORT. THE MAXIMUM FORCE REQUIRED TO OPEN A DOOR SHALL NOT
EXCEED 8.5 LBS. FOR EXTERIOR SWINGING DOORS AND 5 LBS. FOR ALL SLIDING, FOLDING AND INTERIOR SWINGING DOORS.
8. ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL HUNG WITH ELONGATED RIMS AT A MAXIMUM OF 17 INCHES ABOVE THE
FLOOR.
9. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE
OF AT LEAST 29 INCHES ABOVE THE FLOOR TO THE BOTTOM OF APRON.
10. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE
OF AT LEAST 27 INCHES HIGH, 30 INCHES WIDE, AND 19 INCITES DEEP UNDERNEATH SINK. THE SINK DEPTH SHALL BE 6.5 INCHES
MAXIMUM.
11. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED
TO PROTECT AGAINST CONTACT. INSULATION OR PROTECTION MATERIALS MAY BE SITE INSTALLED. THERE SHALL BE NO SHARP
OR ABRASIVE SURFACES UNDER ACCESSIBLE LAVATORIES AND SINKS.
12. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS ( ie. LEVER -OPERATED, PUSH -TYPE, ELECTRONICALLY
CONTROLLED ).
13. WHERE MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE SHALL BE LOCATED WITH A USEABLE SHELF NO HIGHER THAN
44 INCHES ABOVE THE FLOOR.
14. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.25 TO 1.5 INCHES IN DIAMETER WITH 1.5 INCHES OF CLEAR SPACE
BETWEEN THE BAR AND THE WALL.
15. A TOWEL DISPENSER SHALL BE LOCATED NEXT TO ALL ACCESSIBLE LAVATORIES
20 GAGE 6' GALV.
METAL STUDS
USE 10 X 3/4'
DRILLING SMS
AS 51-
20 GAGE E
METAL
USE 'O X 3/4' SELF DRILLING
SMS AS SHOWN FOR STEEL—-
STUD
TEELSTUD TO STEEL TRACK TYP.
20 GAGE 6' GALV. METAL
STUDS 16' O.C. COVER 50TH
SIDES WITH 5/8' GYPSUM
50ARDS PAINTED, VERIFY
COLOR W/ OWNER
20 GAGE 6' GALV.
METAL TRACK
USE h0 X 3/4'
SELF DRILLING
SMS TYP. AS
SHOWN
20 GAGE 6' GALV.
NDR STUDS
SECTION: 88
DETAIL A:
JAMS DETAIL
r
AIX DETAIL, A
I
SECTION: AA
TYP. FRAMING DETAIL.
A I/21.1. -m.
'ro the best of the knowledge of the Engineer or Architect
the plans and specifications herein comply with the 2014
Florida building code and are Signed and Sealed accordingly.
KL ENGINEERING
Khanh Q.Le, PE
Florida License No. 70935
427 Palm Crest Larne
Lake Mary, Ft 32746
Phone(407)361-8017
Fax (407) 61x5695
DRAPING NUMBER
201700081
& SEAL
0111111///
Q U O�jC ///
6 ri/ <�
Y70935
ix
'ATE
�OF¢ / N
IIIIIU��'"
10 (3
VARIES
l
..
AIX DETAIL, A
I
SECTION: AA
TYP. FRAMING DETAIL.
A I/21.1. -m.
'ro the best of the knowledge of the Engineer or Architect
the plans and specifications herein comply with the 2014
Florida building code and are Signed and Sealed accordingly.
KL ENGINEERING
Khanh Q.Le, PE
Florida License No. 70935
427 Palm Crest Larne
Lake Mary, Ft 32746
Phone(407)361-8017
Fax (407) 61x5695
DRAPING NUMBER
201700081
& SEAL
0111111///
Q U O�jC ///
6 ri/ <�
Y70935
ix
'ATE
�OF¢ / N
IIIIIU��'"
MECHANICAL
LEGEND
zAC
RETURN GRILLE
zAC
SUPPLY DIFFUSER
BP
�
BYPASS DAMPER
ZD—X
ZONE DAMPER, ZONE X
OX—Y
THERMOSTAT, SYSTEM X—ZONE Y
AHU
AIR HANDLING UNIT
RTU
ROOF TOP UNIT
CFM
CUBIC FEET PER MINUTE
E®
EXHAUST FAN
TRANSFER GRILLE
WALL MOUNTED AIR DIFFUSER
o
101
C*1
�
N
M
O
�
EXISTMG
EXISTING
V)
r r
G1=NERAL HVAC NOTES:
1. HVAC SYSTEM IS EXISTING. OUTDOOR AIR CALCULATIONS ARE PROVIDED PER TABLE THIS SHEET.
®
EXISTING
5 -TON RTU
-2
V2
W
EXISTING AIR CONDITIONING UNIT SCHEDULE
—
�
H
BTUH
A/C
COOLING
HEATING
DESIGN CFM
OA CFM
REMARK
EXISTING
EXISTMG
RTU -1
7 TON
4.5 kw
2800
500
EXISTING
RTU -2
5 TON
4.5 kw
2000
400
EXISTING
EXI6TMG
EXISTINCa
EXISTMG SUPPLY TYP.
u
EXISTING FLEX
DUCT TYP.e
AIR BALANCE SUMMARY (CFM)
���
MARK SUPPLY RETURN OUTSIDE EXHAUST PRESSURE SERVING
��
H
AIR AIR AIR AIR
$ g
RTU -1 2800 2300 500 -- 500 SPACE
EXISTING
EXISTMG
RTU -1 2000 1600 400 -- 400 SPACE
$
W
EF -1 1 50 1 —50 1 BATHROOM
EF -1 -- -- 50 1 —50 1 BATHROOM
TOTAL +900
OUTSIDE FRESH AIR REQUIRED (CFM) CALCULATION
TABLE 403.3 FMC -2014
gg
PEOPLE OUTDOOR AIRFLOW RATE IN
OUT AIR REQUIRED
a
z
BREATHING ZONE, Rp CFM/PERSON
p_
3
No OF PEOPLE = 62
7.5 CFM/ PERSON
465 CFM
EXISTNG
EXISTING
EXI511NG EXISTM!s��
Pz = 62
s
AREA OUTDOOR AIRFLOW RATE IN
BREATHING ZONE, Ra CFM/FT2
OUTSIDE AIR REQUIRED
Az = 3715 SF
0.06 CFM/ SF
223 CFM
£ SIT
§
TOTAL REQUIRED = 465 CFM + 223 CFM = 688 CFM
s
TOTAL PROVIDE = 900 CFM = OK ( BY RTU -1 AND RTU -2))43
s
HVAC
PLAN
SIGT
SCALE: 1/4" = 1-0"
KL ENGR4MU iG
Khanh Q. Le, PE
Florida License No. 70935
427 Palm Crest Late
= ��
Lake Mary, Fl 32746
bl, ��FTA3
�
Phone (407) 361-8017
Fax (407) 610-5695
�?[)
'/ � •f}� 41
To
andist ecif at o��s he of the
co „',ly h 90 a t
i�4N
plans wi the DRAWING NUMBER
P P P7
Florida building code and are Signed surd Sealed accordingly. 201700081
101
f
& SEAL
935
;1z-
EOF ,W:Z
_E�,
IN��
C*1
�
N
M
O
�
N
f
& SEAL
935
;1z-
EOF ,W:Z
_E�,
IN��
ELECTRICAL LEGEND
PHONE / DATA JACK CAT5 I -RED, I -WHITE, I -BLUE W/ INSERT
0 PHONE / DATA JACK CAT5 I WHITE INSERT
Vx4 QUAD PHONE JACK CAT5 1 WHITE INSERT
® SPECIAL PURPOSE OUTLET
1P DUPLEX RECEPTACLE
*G 20A DEDICATED RECEPT W/ ISOLATED GROUND
R0 20A DEDICATED RECEIPT
75 4'X6' PLYWOOD TELEPHONE: EQUIP. 5ACK50ARD
QUAD RECEPTACLE
DEDICATED QUAD RECEPTACLE
EMERGENCY EXIT LIGHT -BATTERY SACK -UP
® 24' x 24' A/C DIFFUSER
® 24' x 24' A/C RETURN GRILL
Q 2' x 4' FLUORESCENT FIXTURE
® 2' x 4' FLUORESCENT FIXTURE (DUAL -BALLAST)
® WAREHOUSE HIGH -BAY FIXTURE (DUAL -BALLAST)
® WAREHOUSE HIGH -SAY FIXTURE
WAREHOUSE NIGH -SAY FIXTURE:FUTURE
EMERGENCY 5ATTERY SACK UP LT.
2<1 FLOOD LIGHTS
n SMOKE ALARM - DIRECT WIRED:
CTO THERMOSTAT
Q CABLE T.Y. OUTLET:
$" OCCUPANCY MOTION SENSOR SWITCH
SWITCH
3 WAY SWITCH
WALL MOUNTED FLUORESCENT FIXTURE
r -{ FLUORESCENT FIXTURE
GROUND FAULT INTERRUPTER:
WEATHER PROOF GROUND FAULT INTERRUPTER
p JUNCTION SOX
® EXHAUST FAN:
® CEILING LIGHT/EXHAUST FAN COM50
WALL MOUNT LIGHT OUTLET:
C� LOW VOLTAGE SPOT LIGHT (WALL WASHER)
OO PENDANT LIGHT
OO VAPOR PROOF HIGH HAT
RECESSED IN CEILING HIGH -HAT -15W
WAREHOUSE FAN -FUTURE
WAREHOUSE FAN
z1 EXT. VP HH 15OW MAX.
X EXT. VP HH 15OW MAX. W/ MOTION SENSOR
® MOTION SENSOR
ELECTRICAL PLAN
SCALE: 3/16" = 1-0"
To the best of the knowledge of the Engineer or Architect
the plans and specifications herein comply with the 20t4
Florida building code and are Signed and Sealed accordingly.
KL ENGWEEMG
Khanh Q. Le, PE
Florida License No. 70935
427 Palm Crest Lite
Lake Mary, F132746
Phone(407)361-8017
Fax(407)610-5695
DRAWING NUMBER
201700081
rn
z
0
7
C/1
SIGN & SEAL
cer�sF,.
N0;0 35
h —
-INTEOF W
F` •F<OR1OP' C�� �~
X11/fjVONi� �`��
LIGHTING FIXTURE SCHEDULE
LABEL FIXTURE MANUFACTURER 0
MODEL NUMBER
WATTS PER FIXTURE
MOUNTING REMARKS
C LENSED TROFFER LAMAR
LS -332 -24 -E8 -120 -PA
3 0 32 (96)
RECESSED
D1 EXHAUST FAN/LJGHT KIT COMBO BROAN
HDSOL
50
RECESSED
L EXIT SIGN DUAL -LITE
KSR-LED
SURFACE NOTE 1, 2
M EMERGENCY LIGHT DUAL -LITE
EZ -2F
SURFACE NOTE 1
NOTES:O PROVIDE BATTERY BACKUP/ INVERTER FOR 90 MINUTES OPERATION CONNECT TO UNSWITCHED
HOT LEG OF LOCAL LIGHTING CIRCUIT.
O2 PROVIDE SINGLE OR DUAL FACE, ARROWS AS REQUIRED OR SHOWN ON DRAWINGS, TYPICAL
O3 COORDINATE CEILING TYPES PRIOR TO ORDERING FIXTURES
OALTERNATE MANUFACTURERS ARE POSSIBLE WITH OWNER/ENGINEER
WRITTEN APPROVAL
ELECTRICAL LEGEND
- DATA TERMINAL
Q PHONE TERMINAL
'qx4 QUAD PHONE JACK CAT5 I WHITE INSERT
® SPECIAL PURPOSE OUTLET
DUPLEX RECEPTACLE
*� 20A DEDICATED RECEPT W/ ISOLATED GROUND
01) 20A DEDICATED RECEPT
4'X6' PLYWOOD TELEPHONE EQUIP. BACKBOARD
QUAD RECEPTACLE
DEDICATED QUAD RECEPTACLE
® EXIT LIGHT—BATTERY BACK—UP
EMERGENCY EXIT LIGHT—BATTERY BACK—UP
® 24' x 24' A/C DIFFUSER
® 24' x 24' A/C RETURN GRILL
0 2'x 4' FLUORESCENT FIXTURE
2' x *FLUORESCENT FIXTURE (DUAL—BALLAST)
® WAREHOUSE HIGH—BAY FIXTURE (DUAL—BALLAST)
WAREHOUSE HIGH—BAY FIXTURE
WAREHOUSE HIGH-5AY FIXTURE—FUTURE
EMERGENCY BATTERY BACK UP LT.
FLOOD LIGHTS
SMOKE ALARM — DIRECT WIRED:
10 THERMOSTAT
Q CABLE T.V. OUTLET:
OCCUPANCY MOTION SENSOR SWITCH
$ SWITCH
3 WAY SWITCH
— WALL MOUNTED FLUORESCENT FIXTURE
FLUORESCENT FIXTURE
4 GROUND FAULT INTERRUPTER:
WEATHER PROOF GROUND FAULT INTERRUPTER:
p JUNCTION BOX
® EXHAUST FAN:
® CEILING LIGHT/EXHAUST FAN COM50
WALL MOUNT LIGHT OUTLET:
® LOW VOLTAGE SPOT LIGHT (WALL WASHER)
O PENDANT LIGHT
OO VAPOR PROOF HIGH HAT
RECESSED IN CEILING HIGH -HAT -1511)
',11r WAREHOUSE FAN -FUTURE
WAREHOUSE FAN
0 EXT. VP HH 15OW MAX.
X EXT. VP HH 150W MAX. W/ MOTION SENSOR
® MOTION 5EN50R
® 501DINE 5ALLAST EMERGENCY LIGHT
REFLECTED CEILING PLAN
SCALE: 3/16" = 1-0"
To the best of the knowledge or the Engineer or Architect
the plans and specifications herein comply with the 2014
Florida building code and are Signed and Sealed accordingly.
IAC, ENGINEERING
Khanh Q. Le, PE
Florida License No. 70935
427 Palin Crest Lane
Lake Mary, Fl 327=46
Phone(407)361-8017
Fax(407)61.0-5695
201700081
FM
SIGN & SEAL l
* Tlo 0 35
110: Z
93ATE OF4
DF
LINETYM LEGEND
COLD WATER LINE
------- WASTEWATER LINE
,,WIE TO EXIST,
TIE TO EXIST.
PLUMBING PLAN
SCALE: 3/16" = 1-0"
11ETRIC
MINIMUM PLUMBING FNILMS REQ UMM FO R MNAN'P
SPACE PER FPC TVIRE 403.1
`TYPE
RFQ D.
PRO V.
WATER CID SETS
2
2
TAMORIEB
2
2
URINALS
0
0
I1]�HO WAURFOUNTAINS
1
1
SERVIC E SLNK
1
1
ACCESSAMSHOWIR
0
0
k • l4
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE
WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES.
2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY
FAMILIARIZE THEMSELVES WITH ALL EXISTING CONDITIONS.
3. ALL MATERIALS SHALL BE NEW.
4, REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR
FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR
THE DURATION OF THE WORK.
5. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES,
INSPECTIONS AND TESTS, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND
APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING
EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL
INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES.
6. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION
OF FIXTURES, PIPING AND EQUIPMENT.
7. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID
INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY
DISCREPANCY TO ENGINEER PRIOR TO BEGINNING
CONSTRUCTION.
8. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL
EXISTING UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE
ENGINEER OF ANY DISCREPANCIES.
9. DOMESTIC WATER PIPE SHALL BE TYPE CPVC.
10. SOIL, WASTE, VENT, & STORM PIPING SHALL BE CAST IRON OR SCH 40
PVC IF CODE PERMITS.
11. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL
IN PIPING AND EQUIPMENT CONNECTIONS.
12. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD.
13. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY
PROTECTED BY FILLING VOIDS BETWEEN PIPE AND WALL/FLOOR SLEEVES.
14. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND
WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE
(1) YEAR FROM DATE OF ACCEPTANCE BY OWNER, CORRECTION OF ANY
DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL
INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE
INSTALLATION WHICH MAY HAVE BEEN DAMAGED.
15. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS
IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE
FINISH OF THE WALL IN WHICH IT IS INSTALLED.
16. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND CLEAN OUT
PLUG OR ACCESS PANEL FOR ALL WALL CLEAN OUT.
17, ALL CONTROL VALVES SHALL BE TAGGED AND MARKED, A REPRODUCIBLE
DIAGRAM LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNER/OPERATOR.
18, ALL CONDENSATE DRAIN PIPING SHALL BE SCH 40 PVC WITH 1/2"
THICK TYPE'G' CELLULAR FOAM INSULATION, K=0.28 MINIMUM.
19. TEST DOMESTIC WATER TO HYDROSTATIC PRESSURE OF 100 PSI AND
REMAIN LEAK FREE FOR 24 HOURS. PROVIDE ALL NECESSARY TEST
EQUIPMENT. PERFORM TEST IN PRESENCE OF OWNER'S REPRESENTATIVE.
ENTER TEST RESULTS IN GENERAL CONTRACTOR JOB LOG. STERILIZE WATER
PIPING WITH SOLUTION CONTAINING NOT LESS THAN 50 PARTS PER
MILLION OF CHLORINE AND ALLOW TO REMAIN IN SYSTEM FOR A PERIOD OF
EIGHT (8)HOURS. FLUSH SYSTEM AFTER STERILIZATION, ALL COST FOR
STERILIZATION AND EQUIPMENT SHALL BE PROVIDED BY THE CONTRACTOR.
20. PROVIDE 1" (R=4.0 MIN.) INSULATION FOR ALL HOT WATER LINES.
21. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS
AND APPROPRIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH
GENERAL CONTRACTOR PRIOR TO INSTALLATION.
22. PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR
INDIVIDUAL SHUTOFF.
23. THE DESIGN & INSTALLATION OF THE PLUMBING SYSTEM & ALL APPURTENANCES
SHALL COMPLY STRICTLY WITH THE APPLICABLE PROVISIONS OF THE
FLORIDA BUILDING PLUMBING CODE & THE LOCAL AMENDMENTS TO THE FLORIDA
BUILDING PLUMBING CODE.
n ENGWEEMG
Khanh Q. Le, PE
Florida License No. 70935
427 Palm Crest Lane
Lake rtMary, Fl 32746
Phone (407) 361-8017
Fax (407) 610-5695
"To the best of the knowledge of the Engineer or Architect
the plans and specifications herein comply with the 2014 DIiAVYING NUN
Florida building tale and are Signed and Sealed accordingly. 20170008.
E-�
U
ti
O
P-,
s
t if
SIGN & SEAL l