Loading...
HomeMy WebLinkAbout2306 Palmetto Ave (A) 16-3141DIRT DRIVE WAY WIDTH VARIES SWALE SECTION ALON PALMETTO AVL UE CENTERLINE PL -AN & DRAINAGE 1/8=1'-0" SIDE PROPERTY LINE RECORD COPY REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER .Z—k DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE Q 12/07/2016 CITY OF SANF❑RD C❑MMENTS COMPACTION TEST REQUIRED Results to be Verified at Slab Inspection SANE✓ORD #16-3141 ECEI M E JAN 1 1 2017 O Q w M M 01 i O� �j � F� w LU A � O 03 c . G�I�SE''•. %. 'v 12) ��' ND- 33134 W•; � ;.p W� * Qzz 3 SPATE OF C-) f it SAL \02 �Q� A Z p a J ED L' W w UZq (,) v �o W C) (7 N- = W z Q �Z W Ga J J o � 3 •-� W W p 3 z Pz' lj q U Y Q W a s r �1q > Z f p LOU Z Z Z p W Q l7 J W W o U -j 3 wwwa.. w U W � Gil M N M V O w M O� w Gn w � � in(Z) Z=Q Qax.,Q wa.� PAGE N❑, 1 OF 6 DATES 9-23-16 DRAWN BY W. PAIGE cv O w � � M w �-I Q � � O H o � � N � P.T. 2"x6" WOOD JAMB w/ 1/2"x8" DOOR TRACK O.C.PL . _ I. E ANCHOR BOLTS A 48 0C GARAGE DOOR • � � TOP AND BOTTOM COURSE10 S J...• C: � UR r 3 0 00 I 0 0 ry pq I r` FRONT ELEVATI❑N 1/4'=1'--0' 00 I 0 F] REAR ELEVATION - 1/4'=I' -O' (3 ry pq Cl PU 00 I �D j. 1"x2" TRIM 4#5 VERT, REIN. IN POURED CELL STUCCO FINISH Jamb @ Garaa e Door Detai N.T.S. VENTILATION CALCULATI❑N NOTE:- 1. THE RIDGE VENTS VENTILATE THE ATTIC IN ACCORDANCE WITH THE 2014 FBCR 806,2 TOTAL VENTILATED AREA IS NOT LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED, --- — — — — — — — — — — — I I I I I I OD I i I 0 • I I � I N I i I RIGHTSIDE ELEVATION - 1/4'=l' -O' LEETSIBE ELEVATION - 1/4'=l' -O' � � • � fir' ��►�11G•:���l��i THIS BUILDING HAS BEEN DESIGNED AS AN ENCLOSED STRUCTURE IN ACCORDANCE WITH THE 2014 FLORIDA BUILDING CODE. 1. BASIC WIND SPEED - 150 MPH 2, WIND IMPORTANCE FACTOR - 1 3, BUILDING CATEGORY - II 4. WIND EXPOSURE - B 5, INTERNAL PRESSURE COEFFICIENT - t.18 ECEIVE . JAN 11 2017 , B '1__ __- 03 .G Z-wob: 33h w �-�_ ; N aF • O ° z p . o w E /�/ R0F P A ///// SSiII �\J zoo LL W w Uzq v� = LJ z W q \ Z wow �` g F- z Pg 3 <y vj U Q LJ CL q}AGg > E �z,LLpUU z gz Z 0WW Lo '-'F-�PCI w w W o U APgNJ www( 3 ===a- I-- F- f- a PAGE NEl, 2 of 7 DATE, 9-23-16 DRAWN BY W, PAIGE w w � Z > w Q M -1 OC Gn PAGE NEl, 2 of 7 DATE, 9-23-16 DRAWN BY W, PAIGE I a ' fu a, ( N CDCD r 1 ■ I MAST BEDROOM FAMILY ■ r j Ln ' } 10'-8" CLG VAULT CLG i ru M I I � ■ w z , f .2868, 0 3/-b# 1/2/[3# 81-8# 91-1#■ As 1 1 I ; i '°•4068 I TOW +4,r -4 / BI-FLp I I15.0.�T11 fED]C� ICIFfl HITT11111LIh .. to I o 10'-8" CLG SINK DW ■ 5068 i - W/DISP ■ CD BI-FLD / MAST N BATH I r - i I ' ART SHELF F CLOSET -O" CLGL, I I �.. OPEN FROM j DINING ■ i ABV : ■ I 2-8 " I tl d I I d +s -4' O O (T h" 1 DfNING I KITCHEN � I ��'� i i I VAULT CLG VAULT CLG o I 9 (lJ o _ _ it RANGE U-): , LIZ" MW W/ HOOD (u SHOwF-R 0'-0" FFE tq I - 1 4 ru PANTRY 9 w 3 1 � �N A U 1i{�I r I 7'-6" 5'-0 " I �N I _.._ .. ENTRY I CLG � I��I I it !t ` /_ N i l W I (u _ SINK; 10' 8" CLG 4 N I ooa N ■ d �5 8 2868 13'- 6 i GARAGE I POCKET I i °D L,NONDRY I 1 (u 11'-2" CLG o0 ``6068 - IBI-FLD ■ I ■ I 2668 w cn _ r N r 1 3068 S.C. " fU LINTEL M-4 i n ( W 23.2 -29.3iw w __.._..... & ■ ■ DEN o w I f _w.,-,- ._ ......... I PORCH 10'-8° CLG I 1 I ■ r I I BEAM ABV,,,,, ■ ( k I11'-6" f I - I ■ I � i ! I ! E EGRESS ■ ..... ...... ■ l I 25 S.H. I LINTEL M-4 23,2 -29.3 9070 GARAGE DOOR LINTEL M-16 23,2 -29,3 2'-0M 7'-O" 97 -Op C -0 t ( 61-6# ..B FLOOR PLAN - 1/4'=l' -O' SQ, F❑❑T TABULATI❑NS LIVING AREA 1484 SQ. FT. GARAGE MARK NO. 284 SQ. FT. PORCH ENTRY 55 SQ. FT. COVERED LANAI 205 SQ. FT. TOTAL UPLIFT SAFE LOAD SOLID SOLID #5(1)U(0)L #5(1)U(1)L #5(2)U(1)L DETAIL H& J DETAIL K 2028 SQ. FT, ITEM 5 TYPE DESIGNATION P -PLAIN LINTEL/ [QUANTITY OF #5 BAR AT S - SOLID LINTEL LOWER LINTEL CAVITY [8X16-P-IL/IU1 NOMINAL WIDTH L QUANTITY OF #5 BAR AT NOMINAL HEIGHT UPPER LINTEL CAVITY ENGINEERING SPECIFICATIONS'. i.) SAFE LOADS ARE TOTAL SUPERIMPOSED ALLOWABLE LOADS 2.) DESIGNER MAY EVALUATE CONCENTRATED LOAUS FROM THE SAFE LOAD TABLES BY CALCULATING MAX. RESISTING SHEAR AND MOMENT FOR THE LISTED LINTELS. 3.) SAFE LOADS LISTED ON ALL TABLES ARE IN LINT IS OF POUND PER LINEAR FOOT. GENERAL NOTES'. 1.) CODES 1.1 FLORIDA BUILDING CODE 2014. 1.2 BUILDING CODE REQUIREMEN IS FOR REINFORCED CONCRETE (ACI 318-02). 1.3 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-98). 2.)CONCRETE: 2.1 CONCRETE COMPRESSIVE STRENG T H A T 28 DAYS: 2.1.1 PRE -CAST WISTANDARD REINFORCEMENT4000 PSI MIN. 112 PRECAST WIPRESTRESS REINFORCEMENT -6000 PSI MIN, 2.1.3. GROUT PER ASTM C416 -3000 PSI W1 MAX. 3IB" AGEE RATE, 8" TO 11"SLUMP. 2.2 REINFORCING BARS: 22.1 STEEL PLACED IN PRECAST LINTEL AT TIME OF 3" VENT MAIN 2" VENT REVENT 3' REVENT LAV LAV 3' 2' __j SHOWER WASHER TUB 2, 2' D,W,/ DISP❑SAL LT 3 LAV4#w 2' 2' 2' 3' 2'C KITCHEN SINK WC 3' 2' 4' 3' 4' ❑ CITY SEWER OR SEPTIC TANK PLUMBING RISER N.T.S. DENOTES MASONRY DOWNPOUR WITH 1 NO.5 BAR HOOKED INTO FOUNDATION AT EACH CORNER AND ON BOTH SIDES OF EACH OPENING AND 48 O.C. INTERMEDIATE. 3000 PSI CONC. FILL TOP BARS: (CONCRETE PLACED (SEE SCHED.) IN FIELD) (1) #5 CONTINUOUS OPTIONAL .•, 7/32" STIRRUPS AT 4'-0" cc (TIED OR WELDED) -• 'W BARS (MAIN REINF.) n SEE SCHEDULE "B" BARS - SEE SCHEDULE 7 3/B' NOTES: 1. MINIMUM COVERAGE OF STEEL - 1.5" 2. MN. BEARING REQUIRED AT EA. END - 4" 3. STANDARD FOR REINF. STEEL - ASTM A615 TYPICAL LINTEL SECTION PRECAST CONCRETE FABRICATION ASTM A615 (GRAUE 60) 2.2.2 STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) AS TM A015 (GRADE 40). 2.3 PRESTRESS STRANDS ASTM A416 7 -WINE, STRESS RELIEVED 270 KSI 2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315, 2.5 CONCRE TING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. 3) MASONRY: 3.1 DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICATION OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND ACI 530-02. 32 MINIMUM MASONRY UNI T STRENGTH: F'M 1500 PSI. 3.3 MORTAR SHALL BE TYPE S. 4)STRUCTURAL: 4.1 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8" (WITH A MINIMUM ACCEPTABLE BEARING OF 4" PER THE FLORIDA BUILDING CODE 2010 4.2 FOR LINTELS THAT ARE GREATER THAN 14'4" CLEAR SPAN THEY SHALL BE PROVIDED A TEMPORARY SUPPORT AND THE TEMPORARY SUPPORT SHALL NOT BE REMOVED UNTIL 2 DAYS AFTER GROUT PLACEMENT. ITEM 10 WALL SYMBOLS LEGEND TABLE No. 4 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (PLF) 8" x 16" COMPOSITE LINTELS \\\�����Ilt►t►rl/N///i a \�N B" X 8" X 16" CONC. BLOCK WALL 2 X 4 WOOD STUD WALL 2 X 6 WOOD STUD WALL 40" HIGH 2 X 4 WOOD STUD WALL N yc� •GA/vb .•DENSE'•. MARK NO. LINTEL LENGTH CLEAR SPAN LINTEL TYPE LINTEL TOP BARS LINTEL BOTTOM BARS A BAP, B BAR GRAVITY SAFE LOAD SOLID SOLID #5(1)U(0)L #5(1)U(1)L DETAIL H DETAIL J UPLIFT SAFE LOAD SOLID SOLID #5(1)U(0)L #5(1)U(1)L #5(2)U(1)L DETAIL H& J DETAIL K M-1 2'-10" 1'-6" Precast 2 3 2 2 NONE 10000 10000 10000 10000 M-2 3'-6" 2'-2" Precast 2 3 2 2 NONE 5931 10000 10000 10000 M-3 4'-0" 2'-8" Precast 2 3 2 2 NONE 1 4267 10000 8739 10000 M-4 4'-6" 3'-2" Precast 2 3 2 2 NONE 3211 9167 6592 10000 M-5 4'-8" 3'-4" Precast 2 3 2 2 NONE 2944 8414 6049 10000 M-6 5'-4" 4'-0" Precast 2 3 2 3 NONE 4823 6437 4427 7041 M-7 5'-10" 4'-6" Precast 2 3 2 3 NONE 3923 5015 3600 5430 M-8 6'-4" 5'-0" Precast 2 3 2 4 NONE 4175 4175 2982 4411 M-9 6'-6" 5'-2" Precast 2 3 2 4 NONE 3934 3934 2810 4151 M-10 6'-8" 5-8" Precast 2 3 2 4 NONE 3719 3719 2653 3919 M-11 7'-6" 6'-2" Precast 2 3 2 4 NONE 2917 2917 2030 3060 M-12 7'-8" 6'-4" Precast 2 3 NONE 2796 2796 1932 2931 M-13 8'-0" 6'-8" Precast 2 3 _L2L#4 2 4 NONE 2581 2581 1754 2702 M-14 8'-4" 7'-0" Precast 2 3 2 4 NONE 2396 2396 1600 2506 M-15 9'-4" 8'-0" Precast K4_13. 2 4 NONE 1969 1969 1238 2055 M-16 10'-6" 9'-2" Precast 2 3 2 4 NONE 1 1627 1627 947 1695 M-17 11'-4" 10'-0" Precast 2 3 2 5 NONE 1455 1455 795 1504 M-18 12'-0" 10'-8" Precast 2 3 2 5 NONE 1335 1335 691 1379 M-19 12'-6" 11'-2" Precast 2 #3 2 5 NONE 1257 1257 634 1298 M-20 13'-4" 12'-0" Precast 2 3 2 5 NONE 1144 1144 545 1129 M-21 14'-0" 12'-8" Precast 2 3 2 5 NONE 1101 1066 486 1012 M-22 14'-8" 13'-4" Prestressed 2 3 2 4 NONE 1234 1234 571 1126 M-23 15-4" 14'-0" Prestressed 2 3 2 4 NONE 1160 1160 520 1026 M-24 17'-4" 16'-0" Prestressed 2 3 2 4 NONE 982 982 403 794 M-25 18'-4" 17'-0" Prestressed 2 3 2 5 NONE 849 849 321 633 M-26 20'-0" 18'-8" Prestressed 2 3 2 5 NONE 812 812 299 590 M-27 21'-4" 20'-0" Prestressed 2 #3 2 5 NONE 746 746 262 516 M-28 22'-0" 20'-8" Prestressed 2 3 2 5 NONE 717 717 245 484 M-29 24'-0" 1 22'-8" Prestressed 2 3 2 5 NONE 640 640 205 405 DENOTES MASONRY DOWNPOUR WITH 1 NO.5 BAR HOOKED INTO FOUNDATION AT EACH CORNER AND ON BOTH SIDES OF EACH OPENING AND 48 O.C. INTERMEDIATE. 3000 PSI CONC. FILL TOP BARS: (CONCRETE PLACED (SEE SCHED.) IN FIELD) (1) #5 CONTINUOUS OPTIONAL .•, 7/32" STIRRUPS AT 4'-0" cc (TIED OR WELDED) -• 'W BARS (MAIN REINF.) n SEE SCHEDULE "B" BARS - SEE SCHEDULE 7 3/B' NOTES: 1. MINIMUM COVERAGE OF STEEL - 1.5" 2. MN. BEARING REQUIRED AT EA. END - 4" 3. STANDARD FOR REINF. STEEL - ASTM A615 TYPICAL LINTEL SECTION PRECAST CONCRETE FABRICATION ASTM A615 (GRAUE 60) 2.2.2 STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) AS TM A015 (GRADE 40). 2.3 PRESTRESS STRANDS ASTM A416 7 -WINE, STRESS RELIEVED 270 KSI 2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315, 2.5 CONCRE TING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. 3) MASONRY: 3.1 DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICATION OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND ACI 530-02. 32 MINIMUM MASONRY UNI T STRENGTH: F'M 1500 PSI. 3.3 MORTAR SHALL BE TYPE S. 4)STRUCTURAL: 4.1 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8" (WITH A MINIMUM ACCEPTABLE BEARING OF 4" PER THE FLORIDA BUILDING CODE 2010 4.2 FOR LINTELS THAT ARE GREATER THAN 14'4" CLEAR SPAN THEY SHALL BE PROVIDED A TEMPORARY SUPPORT AND THE TEMPORARY SUPPORT SHALL NOT BE REMOVED UNTIL 2 DAYS AFTER GROUT PLACEMENT. ITEM 10 SPECIA1_ NOTE,,- MIN WALL SYMBOLS LEGEND \\\�����Ilt►t►rl/N///i a \�N B" X 8" X 16" CONC. BLOCK WALL 2 X 4 WOOD STUD WALL 2 X 6 WOOD STUD WALL 40" HIGH 2 X 4 WOOD STUD WALL N yc� •GA/vb .•DENSE'•. SPECIA1_ NOTE,,- MIN w U 03 \\\�����Ilt►t►rl/N///i a \�N Q N yc� •GA/vb .•DENSE'•. U •til A ♦ Z W C3 � w o �'°a STATE �F v caaQ SONi Z)�A /l+1181d11111110y\ Lxf0 v, a UZA\� M rn w`~�In" Li Cl) W Z Q FJ -I H z J L� UY¢W Q�AA n a F--T 0 U y T>I-- Z Z LI_ z 0 L-2 W < HI 'tpq W W W o V p Pcl (U Z wwwE 3 ===a_ I- f - I-- ¢ w U w c) w Q P44 ' w vi con w�Q wax., caaQ PAGE NO. -_ ... ..._...... ...... ... .. -_ DATEI 9-23-16 DRAWN BY W, PAIGE ELECTRICAL PLAN - 1/4'=I' -O' EPL METE GROUND ROD 25 OHMS MIN #6 CONDUCTOR ELECTRICAL SYMBOLS LEGEND 7,035 VA 4500 VA 5000 VA e CEILING FAN ® RECESSED LIGHTS Dishwasher COMB, EXHAUST FAN & LT VA 4'-0" FLOURESENT 1000 SINGLE POLE SWITCH 4p 220 OUTLET v PHONE JACK 1500 PANEL BOX 4D DUPLEX OUTLET VA LIGHTING OUTLET OS.D./C.°, SMOKE DETECTOR + CABLE—READY— OUTLET 0G,F.I. GROUND FAULT OUTLET T FLOOD LIGHTS DISCONNECT ® EXHAUST FAN ONLY 04 QUADRA—PLEX OUTLET ELECTRICAL NOTE: 4/0 AL. 200 AMP MAIN DISC 2" GALV, 4/0 AL. 200 AMP. PANEL BOARD UNDER GROUND SERVICE ELECTRICAL RISER N.T.S. ELECTRICAL DEMAND CALCULATIONS General Lighting @ 3VA/Ft. Small Appllance Circuits Dryer 7,035 VA 4500 VA 5000 VA Laundry Circuits 1500 VA Dishwasher 1200 VA Disposal 1000 VA W � Ek.r� Refrigerator 1500 VA Water Heater 4500 VA Range 12,000 VA Irrigation Pump 2400 VA Other 2400 VA First 10,000 VA @ 100% 43,035 10,000 VA Remainder @ 40% 33,035 A/C & Heat 13,214 15,000 VA Total VA --- 240 117,5 200 AMP, PANEL IS ADEQUATE 1, PLANS DESIGNED ACCORDING TO 2011 NEC. 2, ALL OUTLETS TO HAVE ARC—FAULT CIRCUIT INTERCEPTOR COMBINATI❑N TYPE„ 3. SMOKE ,DETECTORS ALSO DECTECT CARBON M❑N❑XIDE, 4. ALL OUTLETS TO BE TAMPER RESISTANT, INTERSYSTEM BONDING NOTE: 1, INTERSYSTEM BONDING TERMINATION SHALL HAVE AT LEAST (3) GROUNDING OR BONDING CONDUCTORS FOR COMMUNICATION SYSTEMS AND WILL BE ACCESSIBLE FOR CONNECTI❑N AND INSPECTI❑N AND LOCATED IN ACCORDANCE WITH ARTICLE 250.94 2011 NEC. NOTE 1, ALL BEDROOM OUTLETS ARE TO BE ARC FAULT, ECEIVE" JAN 1 1 217 _ Z w U w �n 9 ~ >- 'owl 11I III//���� Q O w rt O W � Ek.r� C') ( . p E3 '^ Q V) •" w a • NO. 3'1X34 a 0 O TATE F • �. z • a Q �i GRID�Zz W, •,. 1 U o Q'/�iS�4NAL ~��///sl111111 W<0 1,1� z0w UUZq a � W"E3 = w c� 8 a ---� PZ z bi� ri d z J FW— Z a 3 UYQW A�QA � 4 Q U Q O E3U_ W � (D HH'tPq W 1-1 Q A PPq(U�Ui z wwwaa- 3 ===a �_ �_F_Q � PAGE NO,__ 4 OF i DATE, 9-23-16 DRAWN BY W. PAIGE w U w �n 9 Q O w rt O C') ( W cn c� O Q Q x w a � PAGE NO,__ 4 OF i DATE, 9-23-16 DRAWN BY W. PAIGE N a c R 'v tr: nnn t Lvv.0 DAA nvv"jj uvry FOUNDATION AT EACH CORNER FOUNDATION PLAN AND ON BOTH SI 'ES OF EACH OPENING AND 48 O.C. INTERMEDIATE. 1/4'=1'-0' ENGINEERING NOTES SOIL 1. S❑IL CLASSIFIED AS SILTY SAND WITH A DESIGN L❑AD-BEARING CAPACITY (ALLOWABLE F❑UNDATI❑N PRESSURE) OF 2,000 PSF. 2. S❑IL BELOW NEW FOUNDATI❑NS SHALL BE COMPACTED TO A MINIMUM OF 98% OF MAXIMUM DENSITY PER ASTM D-1557. CONCRETE & MASONRY 1, CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 318 AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS, 2, REINFORCEMENT STEEL SHALL BE NO, 5 BARS C❑NF❑RMING TO ASTM A615, GR. 40. CONCRETE COVER FOR REINFORCEMENT SHALL BE A MINIMUM OF 3' IN F❑❑TINGS AND 1-1/2' IN BEAMS & COLUMNS. 3, REINFORCEMENT SHALL BE BENT C❑LD, THE MINIMUM DIAMETER OF THE BEND FOR NO, 5 REBAR MEASURED ON THE INSIDE OF THE BAR SHALL BE 3-3/4'. SPLICES SHALL BE LAP SPLICES WITH A MINIMUM OVERLAP OF 25' FOR NO, 5 REBAR. 4. LOAD BEARING CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90, MORTAR SHALL COMPLY WITH ASTM C270, TYPE M, N, OR S C❑NF❑RMING TO ASTM A270, 5. THE MINIMUM NET AREA COMPRESSIVE STRENGTH OF MASONRY SHALL BE 1,900 PSI WHEN USING TYPE M OR S MORTAR AND 2,150 PSI WHEN USING TYPE N MORTAR AS DETERMINED BY THE PRISM TEST METHOD IN ACCORDANCE WITH ASTM C1314. 6. ALL EXTERI❑R WALLS ARE SHEAR WALLS 7, TRUSS STRAP TOLERANCE IS 1-1/2' MAX BETWEEN TRUSS & STRAP. IF NOT, USE TWIST TIES W/ 6 - 6d NAILS @ EACH TRUSS & 3 - 0.1450 TAPC❑NS DRILLED INT❑ CONCRETE, WHERE APPLICABLE. WOOD 1. ALL STRUCTURAL LUMBER SHALL BE SOUTHERN YELLOW PINE (SYP) OR SPRUCE WITH A BENDING STRESS, Flo, NO LESS THAN 1,400 PSI. 2. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE OR MASONRY SHALL BE NATURALLY DURABLE OR PRESERVATIVE TREATED WOOD OR HAVE A VAPOR BARRIER INSTALLED BETWEEN THE WOOD & CONCRETE <15# FELT MIN,) 3. EXTERI❑R WALLS ARE SHEAR WALLS SHALL HAVE A MINIMUM 7/16' THK APA RATED SHEATHING ATTACHED TO STUDS W/ 8d NAILS AT 6' ❑.0 AT PANEL EDGES UNLESS OTHERWISE N❑TED, INTERIOR SHEAR WALLS SHALL HAVE A MINIMUM 7/16' THK APA RATED SHEATHING ATTACHED TO STUDS W/ 8d NAILS 6' D.C. 4. INTERIOR SHEAR WALLS & BEARING WALLS SHALL BE SECURED TO FOOTER W/ HILTI KWIK-B❑LT 2 (5/8' x 7' LG) WEDGE ANCHOR W. 2'x2'xl/8' THK PLATE WASHERS SPACED 21' ❑,C MAX. WITH 3 1/2' MIN. EMBEDMENT 5, ROOF SHEATHING IS A DIAPHRAGM - 1/2' PLYWOOD SHEATHING (4 -PLY) USE 8D RING SHANK NAILS 4' ❑.C. ALL WAYS & NAIL EAVE EDGES 4' D.C. 6. EXTERI❑R WALLS TO HAVE HEADER OVER OPENINGS PER DETAIL 7, ALL CONNECTORS SHALL BE NAILED PER MANUFACTURER'S SPECIFICATI❑NS. IF INT❑ THE 1-1/2' DIMENSI❑N OF 2x's, NAIL SHALL BE 1-1/2' LONG 8, INTERCHANGEABILITY BETWEEN SIMPS❑N & USP CONNECTORS IS ALLOWED USING THE APPROPRIATE CROSS REFERENCE EXTERI❑R FINISH 1. A WATER RESISTANT BARRIER IN COMPLIANCE WITH ASTM D226 SHALL BE APPLIED OVER STUDS OR SHEATHING PRI❑R TO APPLICATI❑N OF CEMENT PLASTER FINISH AND HAVE PERFORMANCE EQUAL TO AT LEAST TWO LAYERS OF GRADE D PAPER, 2. INSTALLATI❑N OF EXTERIOR LATHING & FRAMING OVER FRAME WALLS SHALL COMPLY WITH ASTM C1063 3, EXTERI❑R PLASTER SHALL COMPLY WITH ASTM C926. OVER MASONRY CONSTRUCTION, SCRATCH COAT SHALL BE APPROXIMATELY 3/8' THICK AND THE FINAL COAT APPROXIMATELY 1/4' THICK. OVER SHEATHED WOOD FROM CONSTRUCTION, A 3 -COAT SYSTEM SHALL BE EMPLOYED RESULTING IN A TOTAL THICKNESS OF 7/8'. FOUNDATIDN NOTE 1. SEE SHEET 6 OF 7 FOR F❑UNDATI❑N SECTI❑NS. CEIVE JAN 1 1 2017 F- H U a3 F- W � C/7 W � J • L�4-y.� C7�OM �� La Ci �., •. to W cit ftl w ca �o� H • 4 Qax..,Q C-1 H • • 'f o �� t��'� o W c)Z Pa wH� = w \�\ F- L3 l7 Z w H H q F � �` o wow F- Z Pq H } Q w w 0 Z��O r H�pU Z i < LL- J Q) WWI'pq Q w Z A pq W H Q LA ww(L 3 ___CL F- F- F- Q PAGE N0, DATE, 9-23-16 DRAWN BY W, PAIGE U W � C/7 W Ltl Q ✓ L�4-y.� C7�OM W cit ftl w ca �o� zxQ Qax..,Q wa.Q PAGE N0, DATE, 9-23-16 DRAWN BY W, PAIGE i 2 X 6 OVER FRAMING ur F'AKAt't I 101-81, R❑❑P FRAMING PLAN - 1/4'=l' -0' SEE TIE DOWN SCHEDULE METAL C❑PING F T R FOR ANCHORAGE 7/8' THICK STUCCO OVER TYVEK 2 PLY GRANGULAR MODIFIED ROOFING OVER 1/2' PLYWOOD SHEATHING NAILED AT 4. O.C. 12 X 12 FLASHING OVER 1/2' PLYWD, SHEATHING NAILED //'ITEIM 11 EDGES 6. O.C. W/8D RING SHANK NAILS INTERMEDIATE OVER PRE-ENGINEERED ROOF TRUSSES HERE AT 4' O.C. THROUGHOUT OVER AT 2'-0' O.C. SEE TIE DOWN SCHEDULE 2 X 4'S 16' 0, C. VENTED ALUMINUM FOR ANCHORAGE S❑PETTY USE SIMPSON SP4 FOR STUD TO � BOTTOM PLATE AND TOP PLATE r,-�-••• iu N PRE-ENGNR D ROOF TRUSSES 24 O.C. N CONNECTION. FOR BOTTOM PLATE TO TOP OF THE POURED SOLID TIE BEAM USE 1/2' X 6' RED HEADS 32' O.C. 16d NAILS AT 12' ❑.C. R-30 INSULATION FOR 2 X 6 TAILS TO TRUSSES, 5/8' DRYWALL CEILING MASONRY BOND BEAMS SHALL BE SEE' FOR STUD TO PLATE USE e' X 16' WITH 2 CONTINUOS SINGLE HUNG WINDOW A� OOBARSSOLID, ALL ELEVATIONS z w ]R BOTTOM PLATE SIMPSON SP4 32 O.C. OPENINGS DENOTES PRE-ENGINEERED TRUSSES 24' O.C. SLOPING IN THIS DIRECTION _ WALL USE 1/2' TOP AND BOTTOM -D HEADS 32' O.C. a a A 3 1' �j SI 8' X 8' X 16' CON(. BLOCK WALL 2 X 6 WALL HEADS LEDGER SECURED TO WITH 1/2' 6' RED FOR 2 X 32' O.C. TOP OF LEDGER SIMPS❑N 6 TO LEDGER USE HU26 ZL h `o d x. N �2 TO BE AT 10'-4' A.F.F. U O (U t0 x (U 2 X112 HEADER USE SIMPSON H-1 CLIP FOR 2 X 6 TO HEADE . USE SIMPSON HU212-2 F❑ HEADER TO WALL C❑NNECTI❑N. TOP OF HEADER IS AT 8'-0' n\/FP rPAMTNr , o 6/-8# EN❑TES CMU TO TOP 2,_o# 2 X 6'S 16' O.C. 0 OVER FR O I ur F'AKAt't I 101-81, R❑❑P FRAMING PLAN - 1/4'=l' -0' Co I O I AMING 1 • • ITEM 11 SECTI❑N A -A N.T.S. VENTILATION CALCULATION NOTE: 1. THE RIDGE VENTS VENTILATE THE ATTIC IN ACCORDANCE WITH THE 2014 FBCR 8062 TOTAL VENTILATED AREA IS NOT LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED, USE SIMPSON A35 CLIP FOR 2 X 6 JOIST TO LEDGER, CEMENT TILE OVER 30LB, FELT OVER - 1/2' PLYWD, SHEATHING NAILED AT 4' O.C, EDGES 8' ❑.C. INTERMEDIATE OVER 2 X 6 JOIST 16' 0. C. USE SIMPS❑N H-1 CLIP FOR 2 X 6 JOIST TO HEADER, 4 X 4 HEADER SECURED TO--,,_, H❑RIZ❑NTAL WITH SIMPSON TS 12 STRAP ON EACH END. USE (2) 16d NAILS -- T❑ SECURE H❑RIZ❑NT 2 X 6 BRACING TO UPRIGHT. USE (2) 16d NAILS TO SECURE DIAGONAL 2 X 6 BRACING TO UPRIGHT. 2'-0' BLOCK WALL OF HOUSE 2 X 6 LEDGER SECURED TO WALL WITH 1/2' X 6' REDHEADS 32' O.C. SECURE 2 X 6 UPRIGHT TO WALL WITH (3) 1/2' X 8' a- RED HEADS 18' O.C. I (U OVER HANG DETAIL N.T.S. ITEM 12 1/2' DRYWALL OVER V X 2' FURRING WITH R-4.33 FOIL BACK INSULATION 0 N 2 NO.5 BARS CONT.�� . • L 16' W W W DENOTES 7/8' THICK STUCCO DENOTES MASONRY DOWNPOUR WITH 1 N0.5 REBAR SEE FLOORPLAN FOR LOCATION. WIND❑W INSTALLATION (METHOD A) WEATHER RESITIVE BARRIER (WRB) APPLIED AFTER THE WINDOW INSTALLATION. FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE, STEPS Q APPLY SILL FLASHING ® APPLY BEAD OF SEALANT AT BACK OF WINDOW FLANGE & SET WINDOW (PAN HEAD SCREWS MUST BE USED TO FACILITATE INSPECTION) ® APPLY BEAD OF SEALANT AT SIDE JAMBS APPLY JAMB FLASHING APPLY BEAD OF SEALANT AT HEAD ® APPLY HEAD FLASHING 0 I WATER SHEDDING FASHION, STARTING AT THE BASE OF THE WALL & WORKING TOWARD THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING. TUCK WRB UNDER SILL FLASHING, AND OVER JAMB & HEAD FLASHING. O8 WITH SHEATHING TAPE, CONNECT THE WRB TO THE FLASHING (ALL 4 SIDES) @JAMB FLASHING EXTEND JAMB FLASHING TO OVERLAP SILL FLASHING. EXTEND JAMB FLASHING 8 i¢' ABOVE ROUGH OPENING AT HEAD. APPLY TAPE AT CORNERS TO TEMPORARILY HOLD FLASHING IN PLACE UNTIL WRB IS APPLIED. SEAL THE WINDOW FRAME TO OPENING. APPLY A %' NOM. DIA. BEAD TO THE BACKSIDE (INTERIOR) OF THE WINDOW FLANGE, IN LINE WITH ANY PRE -PUNCHED HOLES OR SLOTS. ® JAMB FLASHING APPLY CONT. SEAL TO THE MOUNTING FLANGES AT THE TOP (HEAD) AND SIDES (JAMBS) OF WINDOW. EXTEND SEALANT AT JAMBS 8 W ABOVE THE R.O. AT HEAD. EMBED JAMB FLASHING INTO SEALANT AND _ FASTEN IN PLACE. (FLASHING C-- GOES OVER SEALANT). A K) SILL FLASHING SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE,—� PLUMB, AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW MANUFACTURER FASTENER SPECIFICATIONS. INTERI❑R VIE�A TOP LEFT CORNER OF WIND❑W FLASHING AT HEAD EXTENDS V BEYOND JAMB FLASHING. ®HEAD FLASHIN, EMBED BOTTOM OF THE HEAD FLASHING AGAINST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. SLASHING DETAIL FOR WINDOWS AND DOORS ON BLACK WALLS ALL INTERIOR WALLS ARE TO BE 2 X 4 SPRUCE 16" O,C CONNECTED TO TOP AND BOTTTOM PLATE TOE NAILED TOP AND BOTTOM, RED HEADED TO FOOTING 21" O,C, 1/2" DTA. RED HEAD, COVERED IN DRYWALL ON BOTH SIDES, NON 1 BEARING r E. WALL SECTION - DRAWN BY W. PAIGE .... ...... SEE TIE DOWN SCHEDULE METAL C❑PING FOR ANCHORAGE 7/8' THICK STUCCO OVER TYVEK 2 PLY GRANGULAR MODIFIED ROOFING OVER 1/2' PLYWOOD SHEATHING NAILED AT 4. O.C. 12 X 12 FLASHING OVER 1/2' PLYWD, SHEATHING NAILED //'ITEIM 11 EDGES 6. O.C. W/8D RING SHANK NAILS INTERMEDIATE OVER PRE-ENGINEERED ROOF TRUSSES HERE AT 4' O.C. THROUGHOUT OVER AT 2'-0' O.C. SEE TIE DOWN SCHEDULE 2 X 4'S 16' 0, C. VENTED ALUMINUM FOR ANCHORAGE S❑PETTY USE SIMPSON SP4 FOR STUD TO � BOTTOM PLATE AND TOP PLATE r,-�-••• iu N PRE-ENGNR D ROOF TRUSSES 24 O.C. N CONNECTION. FOR BOTTOM PLATE TO TOP OF THE POURED SOLID TIE BEAM USE 1/2' X 6' RED HEADS 32' O.C. 16d NAILS AT 12' ❑.C. R-30 INSULATION FOR 2 X 6 TAILS TO TRUSSES, 5/8' DRYWALL CEILING MASONRY BOND BEAMS SHALL BE SEE' FOR STUD TO PLATE USE e' X 16' WITH 2 CONTINUOS SINGLE HUNG WINDOW A� OOBARSSOLID, ALL ELEVATIONS z w ]R BOTTOM PLATE SIMPSON SP4 32 O.C. OPENINGS _ WALL USE 1/2' TOP AND BOTTOM -D HEADS 32' O.C. a 3 1' �j SI 8' X 8' X 16' CON(. BLOCK WALL Co I O I AMING 1 • • ITEM 11 SECTI❑N A -A N.T.S. VENTILATION CALCULATION NOTE: 1. THE RIDGE VENTS VENTILATE THE ATTIC IN ACCORDANCE WITH THE 2014 FBCR 8062 TOTAL VENTILATED AREA IS NOT LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED, USE SIMPSON A35 CLIP FOR 2 X 6 JOIST TO LEDGER, CEMENT TILE OVER 30LB, FELT OVER - 1/2' PLYWD, SHEATHING NAILED AT 4' O.C, EDGES 8' ❑.C. INTERMEDIATE OVER 2 X 6 JOIST 16' 0. C. USE SIMPS❑N H-1 CLIP FOR 2 X 6 JOIST TO HEADER, 4 X 4 HEADER SECURED TO--,,_, H❑RIZ❑NTAL WITH SIMPSON TS 12 STRAP ON EACH END. USE (2) 16d NAILS -- T❑ SECURE H❑RIZ❑NT 2 X 6 BRACING TO UPRIGHT. USE (2) 16d NAILS TO SECURE DIAGONAL 2 X 6 BRACING TO UPRIGHT. 2'-0' BLOCK WALL OF HOUSE 2 X 6 LEDGER SECURED TO WALL WITH 1/2' X 6' REDHEADS 32' O.C. SECURE 2 X 6 UPRIGHT TO WALL WITH (3) 1/2' X 8' a- RED HEADS 18' O.C. I (U OVER HANG DETAIL N.T.S. ITEM 12 1/2' DRYWALL OVER V X 2' FURRING WITH R-4.33 FOIL BACK INSULATION 0 N 2 NO.5 BARS CONT.�� . • L 16' W W W DENOTES 7/8' THICK STUCCO DENOTES MASONRY DOWNPOUR WITH 1 N0.5 REBAR SEE FLOORPLAN FOR LOCATION. WIND❑W INSTALLATION (METHOD A) WEATHER RESITIVE BARRIER (WRB) APPLIED AFTER THE WINDOW INSTALLATION. FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE, STEPS Q APPLY SILL FLASHING ® APPLY BEAD OF SEALANT AT BACK OF WINDOW FLANGE & SET WINDOW (PAN HEAD SCREWS MUST BE USED TO FACILITATE INSPECTION) ® APPLY BEAD OF SEALANT AT SIDE JAMBS APPLY JAMB FLASHING APPLY BEAD OF SEALANT AT HEAD ® APPLY HEAD FLASHING 0 I WATER SHEDDING FASHION, STARTING AT THE BASE OF THE WALL & WORKING TOWARD THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING. TUCK WRB UNDER SILL FLASHING, AND OVER JAMB & HEAD FLASHING. O8 WITH SHEATHING TAPE, CONNECT THE WRB TO THE FLASHING (ALL 4 SIDES) @JAMB FLASHING EXTEND JAMB FLASHING TO OVERLAP SILL FLASHING. EXTEND JAMB FLASHING 8 i¢' ABOVE ROUGH OPENING AT HEAD. APPLY TAPE AT CORNERS TO TEMPORARILY HOLD FLASHING IN PLACE UNTIL WRB IS APPLIED. SEAL THE WINDOW FRAME TO OPENING. APPLY A %' NOM. DIA. BEAD TO THE BACKSIDE (INTERIOR) OF THE WINDOW FLANGE, IN LINE WITH ANY PRE -PUNCHED HOLES OR SLOTS. ® JAMB FLASHING APPLY CONT. SEAL TO THE MOUNTING FLANGES AT THE TOP (HEAD) AND SIDES (JAMBS) OF WINDOW. EXTEND SEALANT AT JAMBS 8 W ABOVE THE R.O. AT HEAD. EMBED JAMB FLASHING INTO SEALANT AND _ FASTEN IN PLACE. (FLASHING C-- GOES OVER SEALANT). A K) SILL FLASHING SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE,—� PLUMB, AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW MANUFACTURER FASTENER SPECIFICATIONS. INTERI❑R VIE�A TOP LEFT CORNER OF WIND❑W FLASHING AT HEAD EXTENDS V BEYOND JAMB FLASHING. ®HEAD FLASHIN, EMBED BOTTOM OF THE HEAD FLASHING AGAINST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. SLASHING DETAIL FOR WINDOWS AND DOORS ON BLACK WALLS ALL INTERIOR WALLS ARE TO BE 2 X 4 SPRUCE 16" O,C CONNECTED TO TOP AND BOTTTOM PLATE TOE NAILED TOP AND BOTTOM, RED HEADED TO FOOTING 21" O,C, 1/2" DTA. RED HEAD, COVERED IN DRYWALL ON BOTH SIDES, NON 1 BEARING r E. WALL SECTION - DRAWN BY W. PAIGE .... ......