Loading...
HomeMy WebLinkAbout1917 W 14 St (A) 18-4244 Exterior remodelF Entrc2l b4% ��.it l, .y Y (_ Rul 1ovt0=%itio1&*w%1s y " y pi t G.�Y � �esidenc�,p,j 1917 West 14th Street, Sanford Florida 32771 APPLICABLE CODES: ALL WORK DONE UNDER THIS CONTRACT SHALL COMPLY WITH: FLORIDA BUILDING CODE 2017 — RESIDENTIAL FLORIDA BUILDING CODE 2017 — MECHANICAL FLORIDA BUILDING CODE 2017 — PLUMBING 2017 FLORIDA ACCESSIBLITY CODE 6th Edition FLORIDA FIRE PREVENTION CODE — 5th EDITION NATIONAL ELECTRICAL CODE - 2017 NOTE: SCOPE OF WORK INCLUDES REMOVAL OF CURVED EXISTING ENTRY STRUCTURE AND REPLACEMENT WITH A CONVENTIONAL WOOD FRAMED ROOF SYSTEM, WITH SLOPES TO MATCH EXISTING. ALSO INCLUDED IN THE SCOPE OF WORK WILL BE VARIOUS DECORATIVE TRIM ITEMS AND MATERIALS AS WELL AS REPLACEMENT OF THE EXISTING FRONT ENTRANCE DOORS. SHUTTERS WILL BE ADDED TO FRONT WINDOWS. FINALLY AN EXISTING DRAINAGE PROBLEM FROM THE ADJACENT GARAGE ROOF WILL BE RESOLVED. THIS PROJECT HAS BEEN DESIGNED TO MEET OR EXCEED REQUIREMENTS CONSISTENT WITH WIND LOADING FOR THIS LOCATION PER FLORIDA BUILDING CODE (Vult = 139 MPH, 3 SECOND GUST; Vasd - 108 MPH) Permit Drawings - 4 September 2018 DRAWING INDEX A-1 Site Plan /General Notes A-2 Demolition Plan / Elevation A-3 Proposed Plan / Elevation S-1 Foundation & Framing Plans & Details Steve Krone AIA architect AR 5770 320 Oak Hill Drive Altamonte Springs, Florida (407) 461-0406 RECORD COPY REVIEWED POR CODE COMPLIANCE PLANS XAMINER r DATE SAN11-01-RU BU'ILD INQ DIuiSION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE #1 8- 4244 el11Lp�,L S EAI. U cu L.W -N 0 L U. ^1 W U 4� Q Q 0 CL .fas awxn utaxa�s r,oa a�w _. r.+ µuwv .y . .- n _ co V .- i O N L .COQ Q Y 0O 4-- a) GENERAL NOTES AND REQUIREMENTS 0 0 �� r 0 All work shall comply with the 2017 Florida Building Code -Residential (.0o ° •° and all other applicable rules and regulations. v o Mn Co o c a 2. The plans and specifications are the property of the Architect and shall not E be used or reproduced in any form without the expressed written Q -F-� 2 o permission of the Architect. Q (� y a� E� CM 0 3. The Architect shall not have control or charge of and shall not be C: (D o c r- - responsible for construction means, methods, techniques, sequences or ,~ o (n procedures, or for safety precautions or programs in connection with the o • � ca a CENTERLINE FOURTEENTH � 0 T-- -STREET— -- — — — work, for the acts or omissions of the Contractor, 5ub-Contractors, or U Q o a U any other entity performing any of the work, or for the failure of any of N ; 0 them to carry out the work in accordance with the contract documents. > L M N C13 LL CCCU: U C 4. The General Contractor and all 5ub-Contractor�� s shall verify all conditions, vi c loo.oa details and dimensions before proceeding with the work and shall be ,L c responsible for coordination of the same. Architect shall be notified ofp Q € a a any discrepancies. cn C _ 0) �Y o cu 5. The General Contractor and all 5ub-Contractor5 shall employ all ca o ; CU necessary safety precaution required for his scope of work. These O E n NCn precautions shall include protection for other 5ub-Contractor5 as well as N -!=! O the general public. All safety precautions shall be coordinated with the M Q V project superintendent. I I G. Job superintendent shall verify all dimensions in field prior to commencing work. 7. Dimensions supersede scale on drawings. DO NOT SCALE THE Q DRAWINGS. 0 EXISTING I -- DRIVEWA 8. It is intended that all work be first quality, and accomplished In a O workmanlike manner by skilled craftsmen using accepted practices and J method appropriate to the trade involved. Z LL WORK O AREA 9. All products and materials shall be installed as per manufacture's guidance 1-- and specifications unless specifically otherwise directed by the Architect. Q 0 l ) o > W LI_ EXISTING I N 10. All 5ub-Contractor5 and Suppliers shall be responsible for coordinating W RESIDENCE their work and certifying that their products meet FLA/ADA Standards. Z (U) W W 1 1. All Sub -Contractors and 5upplier5 may submit alternate bids for similar or W 0 W equal systems, equipment or materials for approval. TheseW alternate shall U W be clearly indicated and separated from the base bid. The suggested Z changes should provide the same quality or workmanship and not diminish W the function on the item or trade. Alternate bids will be evaluated for possible approval by the Owner and the Architect. Z 0 -117 d� W O - 1 2. Unless otherwise indicated, all 5ub-Contractor5 and Suppliers shall W r - provide guarantees based on industry recognized standards for their ZI-- products and services. In no case shall these guarantees remain in effect O W for less than one year from the date of substantial completion. W U- S 13. 5ub- Contractors shall provide the General Contractor with such plans h and Information as may be required for the issuance of Acceptance Certificates. 14. The General Contractor shall be responsible for obtaining all applicable permits. , 15. All work in question Including delivery of materials, contractor's work schedule, parking and site use, finishes and colors shall be coordinated with the Owner. I G. All fabricated items shall be made from field measurements. Provide shop 100.00, drawings or submittals for approval prior to fabrication. 17. General contractor and all sub -contractors shall not avail themselves of any unintentional error or omission and shall be charged with the responsibility of furnishing a complete portion of his contract according to the reasonable implied spirit and intent of the drawings. Change orders will not be granted after the contract Is signed, unless they can be substantiated as an unforeseeable Item, beyond and general Intent and scope of the work. DESCRIPTION 18. All Bidders and Contractors are required, before submitting their proposals, to visit the site of the proposed work and completely Begin 1922.6 feet west of and 710.0 feet south of the familiarize themselves with the nature and extent of the work and any local SITE PLAN � 1 northeast corner of Section 35, Township 19 south, condition that may in any manner affect the work to be performed. 1 r" f-1� V Range 30 east, Seminole County, Florida; thence run Al SCALE: 1" = 20' west 100.0 feet, south 210.0 feet, east 100.0 feet, north 19. All Contractors are reciuired to examine carefully the drawings, 210.0 feet to the point of beginning. specifications, and other documents to inform themselves thoroughly Information shown on this sheet is based on a survey regarding any and all conditions and requirements that may In any manner dated November 28, 1990 prepared by Dennis J. Lewis affect the work. 14�� Associates, Inc. Apopka Florida. 5► - A -1 SITE PLAN 4 September 2018 Permit Drawings ,w uv EXISTING WINDOWS AND STUCCO BOTTOM BAND TO I I I I r- r - _ REMOVE ARCHED ENTRY t STRUCTURE INCLUDING SUPPORT WALLS AND ARCHWAY, CONTINUOUS BACK TO EXISTING SLOPED ROOF F REMOVE EXISTING WALL ABOVE, AND DECORATIVE GLASS PANEL EXISTING— SIDELIGHT REMAIN; OWNER TO REPLACE GLASS INTERIOR-- PARTITION NTERIOR—PARTITION SEE ELEVATION \\ REMO E \\ EXISTI G \\ ENTR 1yCE y � � am 4'-111 q'-1011 VERIFY DIMENSION AND VERIFY THAT DOORS ARE CENTERED AS SHOWN DEMOLITION FLOOR P SCALE �" = l'-0" EXISTI SIDELI T TO REMAI ; OWNEF TO REPLACE GLASS INTERIOR PARTITION EXISTING GARAGE rll&-1 IVV L. &-^16J 1 11Y� ENTRY DOORS AND SIDELIGHTS DEMOLITION (NORTH) ELEVATION SCALE 4" = l'—O" 4 September 2018 - Permit Drawings z 0 0 z W ofW U Z 9 H Z W N Z O ollf W U Z W 0 U) W W 0- 0 O W 0- Q D O J LL D O u - Z Q U) F- W W W F- U) to h- qqr- U) W ti A-2 DEMOLITION PLAN & ELEVATION C O fncu �� 1J L �cuQ Q> c C LlC x3%•c' 0 2 ��: o 0Y c E CO v v > 5 ItI, cu 8 U 0 w t2 cc o r (o A c a � O'er e -mc Q v $ E o '3 ♦ ^^,, E � .r W W O > o c °c N N°'3 O ■� �, O t U C .- corn i V QO N a� c Qo TO L M $¢� LLL y3 r 62,80 v, uj 0 Lu �L .L Q ❑. D fl„ �Q.D C Y c c N O >— O En v CIDH- M Q @ z 0 0 z W ofW U Z 9 H Z W N Z O ollf W U Z W 0 U) W W 0- 0 O W 0- Q D O J LL D O u - Z Q U) F- W W W F- U) to h- qqr- U) W ti A-2 DEMOLITION PLAN & ELEVATION � I � W PROPOSED FLOOR PLAN �i a� SCALE �" = 1'-0" ROOF OVERHANG 12"x12" CONCRETE BLOCK COLUMN; SEE ELEVATION 32" HIGH MASONRY WALL WITH STUCCO FINISH — BOTH SIDES 110V DUPLEX RECEPTACLES; GFI + NP Z TO NEW ENTRANCE ROOF PROFILE SHUTTERS; VERIFY HEIGHT TO EXISTING W I N DON STONE VENEER wl PRECAST CAP EXISTING DOUBLE FRONT DOORS AND SIDELITE GLASS TO BE REPLACED PROPOSED FRONT ELEVATION SCALE "' = 1'-0" 4 September 2018 - Permit Drawings a Q r a O cu 0 Z LL O p Q O fn L > � W V Q W cn a) f) 0 F— W W W Z W (n J 0- Z W 0W F- F -W r � Z O W LL a� ca rn Ir— a 2 O 0 c aD co U 0 sO � c .r c +� CO a w o v, U d' ^ 8 m 0E m v a) N Q. aa) c `. E a� .�.r O $ a)r- (D ^^,, W � E :E.. U ti m 0 c:-�--+ ti cn 0 n O•'-' "' S— C) O c cu a �— N �+ c L) Q 0 °- co L a o CV U o J C �¢ CCf LL 3 C U a)cl) .� rn(ff N L o ` c' v/ �_ M U co fl. 0 CL o¢- —Cn =a)a) _ +) c6 2 �L C Y o v N O a) > co O E O � M Q V O r: �. a v -- c�yQ A-3 PROPOSED PLAN & ELEVATION Q O cf) Z LL O p Q O > � W V Q W W c� f) 0 F— W W W Z W (n J 0- Z W 0W F- F -W r � Z O W LL rn Ir— v -- c�yQ A-3 PROPOSED PLAN & ELEVATION SECURE 2x4 1 OUTLOOKERS TO 1 GABLE END RAFTERS WITH SIMPSON H2.5A — — q'-10" 2'.18° — -- -- ---- -- -- ---- — I1 SECURE LVL BEAMS TO POURED 12"X12" 12"X1211 8"x8" THICKENED SLAB I ( 2x6 '- 2x6 — BLOCK COLUMNS EDGE WITH (1) #5 I i I WITH EMBEDDED CONCRETE ) I) � � I � I COLUMN I STRAPS; (2) W TH FL EDGK I I SET GABLE E SIMPSON HETA 20 CELL WITH( 4) -' r-- ---� r--- --�� #5'9 1 1 1 1 36"x36"x12" CONCRETE RAFTERS 32" I LOWER FOR 2x4 I FOOTING REINF. WITH (4) OUTLOOKERS; #5'S EACH WAY SEE ELEVATION 1 I '` _-1 �:�--- --- —=---•—I— s I 3/51 I 2x6 RAFT RS 0 24" O.G. .,•; ! �..�;•.; SECURE RAFTERS TO +,;.;':..:.� 1 u u WITH 2x6 IES; SEE 8 WIDE x 32 HIGH SECURE I LVL BEAMS WITH .' I • • ' I MASONRY WALL, BOTH SECTIONS i 1 SIMPSON H1 CONNECTOF 51 DES OF ENTRY; OUTLOOKERS TO I / RAFTERS WITH- - — — PROVIDE FILLED CELLS SIMPSON A35 (2500 PSI CONC) wl #5 REINF. LAPPED 25" OVER #5 DOWELS EMBEDDED I x W EXTEND RAFTERS TO IN 6"x8" THICKENED PERMIT ROOFING SLAB EDGE — — CONTINUITY WITH Q ®�— `� I GARAGE AND PROVIDE r _ 8"x8" SLAB EDGE iU/ (1) — — -1 1 BASE FDR FLASHING 4" CONCRETE SLAB; SEE #5 CONTINUOUS I n p 1 NOTES BELOW f F =_4 qi^211 1 .. SECURE NEW MASONRY I STU WALL TO I TO EXISTING WITH #3 UND RSIDE OF ROOF ' DOWELS; DRILL INTO I DEC ; 2x6 016" O.0 w/ 2" EXISTING BLOCK COURSE I SHE THING BOTH SIDES 6" AT JOINTS AND — — — EMBED INTO EPDXY; / EXTEND 12" INTO NEW \ // MASONRY EVERY OTHER \\ SEE 0 ERFRAME DETAIL VALLEY COURSE (16 O.C.); \ / REPEAT AT 12"X1211 \ / COLUMNS NIT— — T — — 1 FOUNDATION PLAN -Il ND_ S1 SCALE„ _ 1,_0„ ECURE P.T. 2x6 NAILER TO TOP CHORD OF EACH \\ // EXISTING TRUSS WIITH i'1 SOIL TREATMENT: PROVIDE "PREMISE 75" OR EQUAL INSECTICIDE IN x 5" GALV. LAG SCREWS WATER SOLUBLE PACKETS. APPLICATION BY INDIVIDUALS OR FIRMS \\ ( // LICENSED BY THE STATE OF FLORIDA TO APPLY TERMITICIDE PRODUCTS. APPLY TREATMENT WITHIN MASONRY VOIDS WHERE MASONRY RESTS ON CONCRETE FOOTINGS DURING CONSTRUCTION. APPLY A FINAL TREATMENT FIVE FEET AROUND PERIMETER OF BBUILDING UILDING AFTER CCONSTRUCTION. STRUC IO . FOLLOW N REQUIREMENTS OF FLORIDA 2 ROOF FRAMING PLAN S1 18 SCALE 1'-0" FLOOR SLAB: 4 INCH THICK CONCRETE WITH 6x6 W 1.4x 141.4 WELDED WIRE MESH OR FIBERMESH REINFORCING (CONTRACTOR'S OPTION) OVER 6 MIL VAPOR BARRIER AND CLEAN FILL, COMPACTED IN 12 INCH LIFTS 12'-3" A.F.F_ 12 SOIL BEARING CAPACITY: FOUNDATION HAS BEEN DESIGNED FOR A 1!� R TOP OF 2x6 0 10'-10" A.F.F. BEARING CAPACITY OF 2,000 PSF. NOTIFY ARCHITECT IF ORGANIC (o MATERIALS (ROOTS, MUCK, VEGETATION) ARE ENCOUNTERED. THESE MUST BE REMOVED. IF FILL IS TO BE INSTALLED, COMPACT IN 12 INCH SIMPSON H1 LAYERS TO ACHEIVE A 015% MAXIMUM MODIFIED PROCTOR DENSITY. EXTEND RAFTER TO GARAGE ROOF FOR l BRG 0 q'-811 A.F.F CONTINUITY AND CONCRETE FOOTINGS: 3,000 PSI MIN. FLASHING 1 r 10'-02" A.F.F I I l FILLED CELLS: 2,500 PSI MIN. I I SUSPENDED STUCCO CEILING; REINFORCING STEEL: ASTM A615 GRADE 60 DEFORMED 3'-1" I GALV : WIRES, 1 2" 1 � ' I MAIN CHHANNEANNELS, SELF I q'-02" A.F.F PORTLAND CEMENT: ASTM C 150, TYPE 1 I I FURRING METAL LATH, 1 STUCCO, PAINTED NORMAL WEIGHT AGGREGATE: ASTM C33 WATER: POTABLE PRESUMPTIVE SOIL LOAD BEARING VALUE . 2,000 PSF 3 SECTION ENTRY COMPACT IF REQUIRED AND TEST TO CONFIRM S 1) SCALE �„ = V-0" 0 0 -cl 2x0 r_— EXISTING ROOF CONTINUOUS 2x6 PLATE SECURE TO EXISTING TRUSS TOP CHORD WITH 1/4"X511 GALV. LAG SCREWS 24" O.C. OVERFRAME DETAIL SCALE 4" = 1 ' -0" SIMPSON A35 2x8 RIDGE 2x4 0 24" O.C. SIM SON LSTA S-19AP ANCHOR 2x4 OUTLOOKERS 12'-311 A.F.F TOP OF 2x6 0 10'-10" A.F.F. 12 I I 1 I I I SECTION @ GABLE END SCALE J" = 1'-0" BRG 0 q'-8" A.F.F -8 T- r.__ o 1 NEW CONSTRUCTION HAS BEEN DESIGNED IN ACCORDANCE �,.. 8mv�i o n r L cul CHAPTER 3 "BUILDING PLANNING", SECTION R301 "DESIGN CRITERIA" cu O CL L rn 0) c cu C aci ULTIMATE DESIGN WIND SPEED (Vult) - 3 SECOND GUST : 1301 MPH [FIG. R301.2(3)3 _116-a Y 3 C c �1 N PROJECT DOES NOT LIE IN WIND BORNE DEBRIS REGION [FIG. R301,2(4)3 NE Z aca a) 2 o > o c' 2 Y �"'� ti N.. RISK CATEGORY: II (FBC 2017 TABLE 1604.5) O ■� Op co BUILDING MEAN HEIGHT IS LESS THAN 30 FT O c a ROOF SLOPE: 26.58 dog - 6 IN 12 PITCH Q o �o cu FRAMING CRITERIA T- r.__ o 1 NEW CONSTRUCTION HAS BEEN DESIGNED IN ACCORDANCE '~ :E d' 8mv�i WITI-I FLORIDA BUILDING CODE -RESIDENTIAL 2017 L cul CHAPTER 3 "BUILDING PLANNING", SECTION R301 "DESIGN CRITERIA" O CL 2 WIND DESIGN CRITERIA: C aci ULTIMATE DESIGN WIND SPEED (Vult) - 3 SECOND GUST : 1301 MPH [FIG. R301.2(3)3 _116-a Y 3 NOMINAL DESIGN WIND SPEED (Vasd) : 106 MPH CWIND SPEED CONVERSION TABLE 8301.21.9]U �1 N PROJECT DOES NOT LIE IN WIND BORNE DEBRIS REGION [FIG. R301,2(4)3 NE Z o > o c' EXPOSURE CATEGORY: B (FBC 2017 SECTION 160q.4,3) �"'� ti N.. RISK CATEGORY: II (FBC 2017 TABLE 1604.5) O ■� Op BUILDING MEAN HEIGHT IS LESS THAN 30 FT O c a ROOF SLOPE: 26.58 dog - 6 IN 12 PITCH Q o Co O ROOF COMPONENT t CLADDING LOADS -TABLE R301.2(2) (WORST CASE FOR ALL ZONES) N c >, N POSITIVE: +20.3 paf NEGATIVE: (-83.1 paf) > L M 8 t WALL COMPONENT t CLADDING LOADS -TABLE R301.2(2) (WORST CASE FOR ALL ZONES) LL j POSITIVE: +95.9 psf NEGATIVE: (-47.2 paf) `{_j N cu a) — CD9 o LIVE AND DEAD LOADS: > co U CL OQ-a ROOF DEAD LOAD: CEILING 3of ROOFING 2 psf, __ (n c c a) ROOF DECK 2 paf TOTAL 7 psf _ (D ca O ROOF LIVE LOAD (TABLE 8301,6): 16 PSF _IleCO N v a) TOTAL ROOF LOADS 23 pmf ®6:12 PITCH Q EN � cu MAXIMUM DEFLECTION: V240 O 'O♦ M Q U A STRUCTURAL FRAMING LUMBER TO BE NO 2 SOUTHERN PINE 5 SECURE OSB OR PLYWOOD ROOF AND WALL SHEATHING TO FRAMING WITH 8d RING SHANK NAILS AT 6" O.C. ALONG EDGE FRAMING AND 6" O.0 AT INTERMEDIATE FRAMING PER R803.2.3.1; a FASTENER MINIMUM REQUIREMENTS • 0.113 NOMINAL SHANK DIAMETER • RING DIAMETER OF 0.012 OVER SHANK DIAMETER • 16 TO 20 RINGS PER INCH • 0,280 INCH FULL ROUND HEAD DIAMETER 2 INCH NAIL LENGTH A35 11 4' w• H ETA 20 H2.5A H 1 CONNECTOR INSTALL CONNECTORS USING MANUFACTURER'S RECOMMENDED FASTENERS 4 September 2018 - Permit Drawings z O Q O z W W U Z F -- z W z O LL W U z W O W W J O W 0- Q o LJ.. O LL 0 O I.L.. z Q W W W _ F_ d' r W r S-1 FOUNDATION & FRAMING