Loading...
HomeMy WebLinkAbout1451 Rinehart Rd (A) 18-2505/ o, 3 O On 0 0 U) 0 U 0 cn O W Z h 0 U 0 0 J U O / U) / / VICINITY MAP SCALE: 1 IN.= 1,400 FT PROJECT INFORMATION: PERMITTED USES: ALL USES PERMITTED WITHIN GC -2 ZONING DISTRICT. RECLAIMED WATER: IRRIGATION TO BE PROVIDED BY CONNECTION TO CITY OF SANFORD'S RECLAIMED WATER SYSTEM. RINEHART-GREENWAY coMMONS PD SOLID WASTE: SOLID WASTE REMOVAL TO BE PROVIDED BY CITY OF SANFORD, WITH DISPOSAL AT THE SEMINOLE COUNTY LANDFILL. ALL HAZARDOUS SUBSTANCES ASSOCIATED WITH THIS DEVELOPMENT'S OPERATIONS SHALL BE PROPERLY STORED ABOVE GROUND AND REMOVED ON A REGULAR BASIS IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND ORDINANCES. EXISTING ZONING: (PD) PLANNED DEVELOPMENT FUTURE LAND USE: WESTSIDE INDUSTRY AND COMMERCE TAX PARCEL ID NUMBER: (UNASSIGNED) PROPOSED LAND USE TABLE: USE AREA (AC.) PD 8.61 MAX. NON-RESIDENTIAL INTENSITY TOTAL PROJECT AREA: 8.61 ACRES 0.50 F.A.R. SOIL TYPES: ASTATULA-APOPKA FINE SANDS BASINGER, SAMSULA, AND HONTOON SOILS MYAKKA AND EAUGALLIE FINE SANDS TAVARES-MILLHOPPER MAX. RESIDENTIAL INTENSITY 0.20 DU/AC. MAX. BUILDING HEIGHT: 8- STORIES MAXIMUM, UP TO 100 FT. MAX I.S.R. MIN. OPEN SPACE 80% (6.89 AC.) 20% (1.72 AC.) FLOOD INSURANCE RATE MAP: THE SITE IS LOCATED IN ZONE X PER THE "FIRM" MAP NO. 12117CO065F, DATED SEPTEMBER 28, 2007. PROJECT BENCHMARK: SOURCE: SOURCE IS "BOUNDARY AND TOPOGRAPHIC SURVEY OF A PORTION OF LOT 1, PINE LAKE GROVES, PLANT BOOK 9, PAGE 27, SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, SEMINOLE COUNTY, FLORIDA DATED NOVEMBER 16, 2017. THE ELEVATIONS SHOWN HEREON ARE BASED ON SEMINOLE COUNTY VERTICAL CONTROL NETWORK. SPECIFICALLY, BENCHMARK DESIGNATION NUMBER 8135303, BEING A SEMINOLE COUNTY NAIL AND DISK STAMPED 813-5303 IN CONCRETE MEDIAN OF ENTRANCE TO STATE ROAD 417, 125' EAST OF CENTER LINE OF RINEHART ROAD PUBLISHED ELEVATION IS 53.32 FEET, RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM (NAVD) OF 1988. UTILITY INFORMATION: WATLR: CITY OF SANFORD WASTEWATER: CITY OF SANFORD REUSE: CITY OF SANFORD ELECTRIC: FIRE: NATURAL GAS: TELEPHONE.: SOLID WASTE: FLORIDA POWER AND LIGHT CITY OF SANFORD FLORIDA PUBLIC UTILITIES AT&T CITY OF SANFORD ADJACENT STREETS: STREET LOCATION R.O.W. WIDTH SR. 417 SOUTH U RINEHART RD. WEST 0 Filename C000 Cover — Rinehart Commons PH1.dwg VARIES 140 FT Plot Date Sep. 18, 2018 8:53am CONTACT INFORMATION: DEVELOPER: RINEHART PARTNERS, LLC. PHILLIP HOLLIS, MS/PE, MANAGER 1190 BUSINESS CENTER DRIVE SUITE 1010 LAKE MARY, FL, 32746 SURVEYOR: BENCHMARK SURVEYING AND MAPPING, LLC 3110 RED FOX RUN KISSIMMEE, FLORIDA 34746 P: 407-509-9674 E: BENCHMARKSURVEYINGANDMAPPING.COM ATTN: JOE JENKINS ENGINEER/AGENT: KLIMA WEEKS CIVIL ENGINEERING, INC. SELBY G. WEEKS, P.E., LEED AP 385 DOUGLAS AVE., STE. 2100 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 407.478.8750 FAX: 407.478.8749 E-MAIL: SWEEKSOKLIMAWEEKS.COM CONSTRUCTION PLANS i45i RINEHART ROAD, SANFORD FL. SEPTEMBER 2018 DRAWING INDEX: KEY MAP SCALE: 1 IN.= 200 FT RECORD LEGAL DESCRIPTION (Prepare( Surveying and Mapping, LLC., field date: November 16,2017): SITE A PARCEL OF LAND LOCATED IN THE NORTHWEST 1/4 OF SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, SEMINOLE COUNTY, FLORIDA, BEING A PORTION OF LOT 1, PINE LAKE GROVES, AS RECORDED IN PLAT BOOK 9, PAGE 27, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA, AS RECORDED OFFICIAL RECORD BOOK 4447, PAGE 1085, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: A PORTION OF LOTS 1 AND 2, PINE LAKE GROVES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 9, PAGE 27, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA, LYING IN THE NORTHEAST 1/4 OF SECTION 32, TO;ASHIP 19 SOUTH, RANGE 30 EAST, AND THE NORTHWEST 1/4 OF SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, AS RECORDED IN OFFICIAL RECORDS BOOK 1265, PAGE 1570, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA, LESS THAT PORTION LYING IN RINEHART ROAD ( 140 -FOOT RIGHT-OF-WAY), AS SHOWN ON FLORIDA DEPARTMENT OF TRANSPORTATION RIGHT OF WAY MAP SECTION NO. 77160-2441, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS FROM THE NORTHWEST CORNER OF SAID SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, (A 5"CONCRETE MONUMENT AS NOW EXISTS), RUN THENCE NORTH 89'52'39" EAST ALONG THE NORTH LINE OF SAID SECTION 33 A DISTANCE OF 1318.88 FEET TO A POINT ON THE EAST LINE OF SAID PINE LAKE GROVES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 9, PAGE 27, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA; THENCE SOUTH 00'25'04" WEST ALONG THE EAST LINE THEREOF 30.00 FEET TO THE NORTHEAST CORNER OF SAID LOT 1 FOR THE POIN 1 OF BEGINNING; THENCE CONTINUE ALONG THE EAST LINE OF SAID LOT 1 SOUTH 00'25'04" WEST 487.21 FEET TO A POINT ON THE NORTHERLY EXISTING LIMITED ACCESS RIGHT OF WAY LINE OF STATE ROAD 417 (PARCEL 320 PARI C) AS SHOWN ON FLORIDA DEPARTMENT OF TRANSPORTATION RIGHT OF WAY MAP, SECTION 77160-2441; THENCE NORTH 62'49'00" WEST ALONG SAID RIGHT OF WAY LINE 450.59 FEET TO THE BEGINNING OF A CURVE CONCAVE SOUTHERLY, HAVING A RADIUS OF 825.20 FEET, A CENTRAL ANGLE OF 27'10'59" AND A CHORD BEARING OF NORTH 76'24'30" WEST; THENCE WESTERLY ALONG THE ARC OF SAID CURVE AND SAID RIGHT OF WAY LINE 391.50 FEET FOR THE END OF SAID CURVE; THENCE CONTINUING ALONG SAID RIGHT OF WAY LINE SOUTH 90'00'00" WEST 530.45 FEET TO A POINT ON THE EAST LINE OF SAID RINEHART ROAD, BEING A POINT ON A CURVE CONCAVE WESTERLY, HAVING A RADIUS OF 2616.47 FEET, A CENTRAL ANGLE OF 04'06'35" AND A CHORD BEARING OF NORTH 02°43'16" EAST; THENCE NORTHERLY ALONG THE ARC OF SAID CURVE AND SAID EAST LINE OF RINEHART ROAD 187.67 FEET TO A POINT ON THE NORTH LINE OF SAID LOT 1; THENCE, DEPARTING SAID EAST LINE OF RINEHART ROAD, NORTH 89'52'39" EAST ALONG SAID NORTH LINE OF LOT 1 A DISTANCE OF 1302.90 FEET TO THE POINT OF BEGINNING. CONTAINING 7.718 ACRES, MORE OR LESS. SUBJECT TO EASEMENTS OF RECORD. RESERVING UNTO THE GRANTOR ALL RIGHTS OF INGRESS, EGRESS, LIGHT, AIR AND VIEW ALONG THE AFOREDESCRIBED NORTHERLY LIMITED ACCESS RIGHT OF WAY LINE OF STATE ROAD 417 AND THE EAST RIGHT OF WAY LINE OF RINEHART ROAD. NOTE: THE PLANNED DEVELOPMENT ALSO INCLUDES: A PORTION OF WILSON AVENUE BEING A 30.00 FOOT WIDE RIGHT OF WAY AS SHOWN ON PINE LAKE GROVES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 9, PAGE 27, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA. SAID PORTION OF WILSON ROAD LYING IN THE NORTHWEST 1/4 OF SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, BEING NORTH OF LOT 1 OF SAID PINE LAKE GROVES AND BEING MORE PARTICULAR DESCRIBED AS FOLLOWS: COMMENCE AT THE NORTHWEST CORNER OF THE NOR i'HWEST 1/4 OF SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, THENCE NORTH 89'52'39" EAST, ALONG THE NORTH LINE OF SAID NORTHWEST 1/4, A DISTANCE OF 15.94 FEET TO THE EAST RIGHT OF WAY LINE OF RINEHART ROAD, A 140.00 FOOT WIDE PUBLIC RIGHT OF WAY ACCORDING TO SEMINOLE COUNTY RINEHART ROAD EXTENSION RIGHT OF WAY V'.P, SAID POINT ALSO BEING THE POINT OF BEGINNING; THENCE CONTINUE NORTH 81:'52'39" EAST, ALONG THE NORTH LINE OF SAID NORTHWEST 1/4, A DISTANCE OF 1302.90 FEET 70 THE NORTHERLY EXTENSION OF THE EAST LINE OF LOT 1 OF SAID PINE LAKE GROVES; THENCE SOUTH 00'25'04" WEST, ALONG SAID NORTHERLY EXTENSION, A DISTANCE OF 30.00 FEET TO THE NORTHEAST CORNER OF LOT 1 OF SAID PINE LAKE GROVES; THENCE SJUTH 89'52'39" WEST, ALONG THE NORTH LINE OF LOT 1 OF SAID PINE LAKE GROVES, A DISTANCE OF 1302.90 FEET TO THE EAST RIGHT OF WAY LINE OF SAID RINEHART ROAD, SAID POINT BEING ON A CURVE CONCAVE WESTERLY, HAVING A RADIUS OF 2616.47 FEET, A CENTRAL ANGLE OF 00'39'25" AND A CHORD BEARING OF NORTH 00'20'16" EAST; THENCE NORTHERLY, ALONG THE ARC OF SAID CURVE AND THE EAST RIGHT OF WAY LINE OF SAID RINEHART ROAD, A DISTANCE OF 30.00 FEET TO THE POINT OF BEGINNING. CONTAINS 0.897 ACRES, MORE OR LESS. I�JQirr A I +�t11� rljr�x� S Nov u 4j, Z y/�"�'✓r�w�l �/JN.t !� ityilr�, �Gu✓,� l�uir� SANFORD FIRE DEPARTMENT THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. AN ISSUED PERMIT SHALL BE DEEMED PERMISSION TO PROCEED WITH WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THESE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE FIRE PREVENTION DIVISION FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS ON THE PLANS, CONSTRUCTION OR OTHER VIOLATIONS OF THE CODE. c" o a E C3 cV N q qp U W c+7 di Uj� o0 3K.Itff ia • z Qx3 J2A. 0o�Q3 weeks o ;" W in� CIVIL ENGINEERING W « Q CERTIFICATE OF AUTHORIZATION No.: 9230 NO. REVISION BY DATE 1 Owner Revisions RZ 03.28.18 2 ..... .................. .. o6.05.18 3 Owner Revisions DB 09.14.18 4 SITE - W4 , ... . ..... . . ... ........ .......... - L rfiD°+{ t.1Px �lL 4R _1�ataS�>:atar"ihar,aa ly 2. �Jt'.0 fifuFtl 1' �xKJG �.:..' VICINITY MAP SCALE: 1 IN.= 1,400 FT PROJECT INFORMATION: PERMITTED USES: ALL USES PERMITTED WITHIN GC -2 ZONING DISTRICT. RECLAIMED WATER: IRRIGATION TO BE PROVIDED BY CONNECTION TO CITY OF SANFORD'S RECLAIMED WATER SYSTEM. RINEHART-GREENWAY coMMONS PD SOLID WASTE: SOLID WASTE REMOVAL TO BE PROVIDED BY CITY OF SANFORD, WITH DISPOSAL AT THE SEMINOLE COUNTY LANDFILL. ALL HAZARDOUS SUBSTANCES ASSOCIATED WITH THIS DEVELOPMENT'S OPERATIONS SHALL BE PROPERLY STORED ABOVE GROUND AND REMOVED ON A REGULAR BASIS IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND ORDINANCES. EXISTING ZONING: (PD) PLANNED DEVELOPMENT FUTURE LAND USE: WESTSIDE INDUSTRY AND COMMERCE TAX PARCEL ID NUMBER: (UNASSIGNED) PROPOSED LAND USE TABLE: USE AREA (AC.) PD 8.61 MAX. NON-RESIDENTIAL INTENSITY TOTAL PROJECT AREA: 8.61 ACRES 0.50 F.A.R. SOIL TYPES: ASTATULA-APOPKA FINE SANDS BASINGER, SAMSULA, AND HONTOON SOILS MYAKKA AND EAUGALLIE FINE SANDS TAVARES-MILLHOPPER MAX. RESIDENTIAL INTENSITY 0.20 DU/AC. MAX. BUILDING HEIGHT: 8- STORIES MAXIMUM, UP TO 100 FT. MAX I.S.R. MIN. OPEN SPACE 80% (6.89 AC.) 20% (1.72 AC.) FLOOD INSURANCE RATE MAP: THE SITE IS LOCATED IN ZONE X PER THE "FIRM" MAP NO. 12117CO065F, DATED SEPTEMBER 28, 2007. PROJECT BENCHMARK: SOURCE: SOURCE IS "BOUNDARY AND TOPOGRAPHIC SURVEY OF A PORTION OF LOT 1, PINE LAKE GROVES, PLANT BOOK 9, PAGE 27, SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, SEMINOLE COUNTY, FLORIDA DATED NOVEMBER 16, 2017. THE ELEVATIONS SHOWN HEREON ARE BASED ON SEMINOLE COUNTY VERTICAL CONTROL NETWORK. SPECIFICALLY, BENCHMARK DESIGNATION NUMBER 8135303, BEING A SEMINOLE COUNTY NAIL AND DISK STAMPED 813-5303 IN CONCRETE MEDIAN OF ENTRANCE TO STATE ROAD 417, 125' EAST OF CENTER LINE OF RINEHART ROAD PUBLISHED ELEVATION IS 53.32 FEET, RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM (NAVD) OF 1988. UTILITY INFORMATION: WATLR: CITY OF SANFORD WASTEWATER: CITY OF SANFORD REUSE: CITY OF SANFORD ELECTRIC: FIRE: NATURAL GAS: TELEPHONE.: SOLID WASTE: FLORIDA POWER AND LIGHT CITY OF SANFORD FLORIDA PUBLIC UTILITIES AT&T CITY OF SANFORD ADJACENT STREETS: STREET LOCATION R.O.W. WIDTH SR. 417 SOUTH U RINEHART RD. WEST 0 Filename C000 Cover — Rinehart Commons PH1.dwg VARIES 140 FT Plot Date Sep. 18, 2018 8:53am CONTACT INFORMATION: DEVELOPER: RINEHART PARTNERS, LLC. PHILLIP HOLLIS, MS/PE, MANAGER 1190 BUSINESS CENTER DRIVE SUITE 1010 LAKE MARY, FL, 32746 SURVEYOR: BENCHMARK SURVEYING AND MAPPING, LLC 3110 RED FOX RUN KISSIMMEE, FLORIDA 34746 P: 407-509-9674 E: BENCHMARKSURVEYINGANDMAPPING.COM ATTN: JOE JENKINS ENGINEER/AGENT: KLIMA WEEKS CIVIL ENGINEERING, INC. SELBY G. WEEKS, P.E., LEED AP 385 DOUGLAS AVE., STE. 2100 ALTAMONTE SPRINGS, FLORIDA 32714 TEL: 407.478.8750 FAX: 407.478.8749 E-MAIL: SWEEKSOKLIMAWEEKS.COM CONSTRUCTION PLANS i45i RINEHART ROAD, SANFORD FL. SEPTEMBER 2018 DRAWING INDEX: KEY MAP SCALE: 1 IN.= 200 FT RECORD LEGAL DESCRIPTION (Prepare( Surveying and Mapping, LLC., field date: November 16,2017): SITE A PARCEL OF LAND LOCATED IN THE NORTHWEST 1/4 OF SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, SEMINOLE COUNTY, FLORIDA, BEING A PORTION OF LOT 1, PINE LAKE GROVES, AS RECORDED IN PLAT BOOK 9, PAGE 27, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA, AS RECORDED OFFICIAL RECORD BOOK 4447, PAGE 1085, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: A PORTION OF LOTS 1 AND 2, PINE LAKE GROVES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 9, PAGE 27, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA, LYING IN THE NORTHEAST 1/4 OF SECTION 32, TO;ASHIP 19 SOUTH, RANGE 30 EAST, AND THE NORTHWEST 1/4 OF SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, AS RECORDED IN OFFICIAL RECORDS BOOK 1265, PAGE 1570, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA, LESS THAT PORTION LYING IN RINEHART ROAD ( 140 -FOOT RIGHT-OF-WAY), AS SHOWN ON FLORIDA DEPARTMENT OF TRANSPORTATION RIGHT OF WAY MAP SECTION NO. 77160-2441, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS FROM THE NORTHWEST CORNER OF SAID SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, (A 5"CONCRETE MONUMENT AS NOW EXISTS), RUN THENCE NORTH 89'52'39" EAST ALONG THE NORTH LINE OF SAID SECTION 33 A DISTANCE OF 1318.88 FEET TO A POINT ON THE EAST LINE OF SAID PINE LAKE GROVES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 9, PAGE 27, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA; THENCE SOUTH 00'25'04" WEST ALONG THE EAST LINE THEREOF 30.00 FEET TO THE NORTHEAST CORNER OF SAID LOT 1 FOR THE POIN 1 OF BEGINNING; THENCE CONTINUE ALONG THE EAST LINE OF SAID LOT 1 SOUTH 00'25'04" WEST 487.21 FEET TO A POINT ON THE NORTHERLY EXISTING LIMITED ACCESS RIGHT OF WAY LINE OF STATE ROAD 417 (PARCEL 320 PARI C) AS SHOWN ON FLORIDA DEPARTMENT OF TRANSPORTATION RIGHT OF WAY MAP, SECTION 77160-2441; THENCE NORTH 62'49'00" WEST ALONG SAID RIGHT OF WAY LINE 450.59 FEET TO THE BEGINNING OF A CURVE CONCAVE SOUTHERLY, HAVING A RADIUS OF 825.20 FEET, A CENTRAL ANGLE OF 27'10'59" AND A CHORD BEARING OF NORTH 76'24'30" WEST; THENCE WESTERLY ALONG THE ARC OF SAID CURVE AND SAID RIGHT OF WAY LINE 391.50 FEET FOR THE END OF SAID CURVE; THENCE CONTINUING ALONG SAID RIGHT OF WAY LINE SOUTH 90'00'00" WEST 530.45 FEET TO A POINT ON THE EAST LINE OF SAID RINEHART ROAD, BEING A POINT ON A CURVE CONCAVE WESTERLY, HAVING A RADIUS OF 2616.47 FEET, A CENTRAL ANGLE OF 04'06'35" AND A CHORD BEARING OF NORTH 02°43'16" EAST; THENCE NORTHERLY ALONG THE ARC OF SAID CURVE AND SAID EAST LINE OF RINEHART ROAD 187.67 FEET TO A POINT ON THE NORTH LINE OF SAID LOT 1; THENCE, DEPARTING SAID EAST LINE OF RINEHART ROAD, NORTH 89'52'39" EAST ALONG SAID NORTH LINE OF LOT 1 A DISTANCE OF 1302.90 FEET TO THE POINT OF BEGINNING. CONTAINING 7.718 ACRES, MORE OR LESS. SUBJECT TO EASEMENTS OF RECORD. RESERVING UNTO THE GRANTOR ALL RIGHTS OF INGRESS, EGRESS, LIGHT, AIR AND VIEW ALONG THE AFOREDESCRIBED NORTHERLY LIMITED ACCESS RIGHT OF WAY LINE OF STATE ROAD 417 AND THE EAST RIGHT OF WAY LINE OF RINEHART ROAD. NOTE: THE PLANNED DEVELOPMENT ALSO INCLUDES: A PORTION OF WILSON AVENUE BEING A 30.00 FOOT WIDE RIGHT OF WAY AS SHOWN ON PINE LAKE GROVES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 9, PAGE 27, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA. SAID PORTION OF WILSON ROAD LYING IN THE NORTHWEST 1/4 OF SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, BEING NORTH OF LOT 1 OF SAID PINE LAKE GROVES AND BEING MORE PARTICULAR DESCRIBED AS FOLLOWS: COMMENCE AT THE NORTHWEST CORNER OF THE NOR i'HWEST 1/4 OF SECTION 33, TOWNSHIP 19 SOUTH, RANGE 30 EAST, THENCE NORTH 89'52'39" EAST, ALONG THE NORTH LINE OF SAID NORTHWEST 1/4, A DISTANCE OF 15.94 FEET TO THE EAST RIGHT OF WAY LINE OF RINEHART ROAD, A 140.00 FOOT WIDE PUBLIC RIGHT OF WAY ACCORDING TO SEMINOLE COUNTY RINEHART ROAD EXTENSION RIGHT OF WAY V'.P, SAID POINT ALSO BEING THE POINT OF BEGINNING; THENCE CONTINUE NORTH 81:'52'39" EAST, ALONG THE NORTH LINE OF SAID NORTHWEST 1/4, A DISTANCE OF 1302.90 FEET 70 THE NORTHERLY EXTENSION OF THE EAST LINE OF LOT 1 OF SAID PINE LAKE GROVES; THENCE SOUTH 00'25'04" WEST, ALONG SAID NORTHERLY EXTENSION, A DISTANCE OF 30.00 FEET TO THE NORTHEAST CORNER OF LOT 1 OF SAID PINE LAKE GROVES; THENCE SJUTH 89'52'39" WEST, ALONG THE NORTH LINE OF LOT 1 OF SAID PINE LAKE GROVES, A DISTANCE OF 1302.90 FEET TO THE EAST RIGHT OF WAY LINE OF SAID RINEHART ROAD, SAID POINT BEING ON A CURVE CONCAVE WESTERLY, HAVING A RADIUS OF 2616.47 FEET, A CENTRAL ANGLE OF 00'39'25" AND A CHORD BEARING OF NORTH 00'20'16" EAST; THENCE NORTHERLY, ALONG THE ARC OF SAID CURVE AND THE EAST RIGHT OF WAY LINE OF SAID RINEHART ROAD, A DISTANCE OF 30.00 FEET TO THE POINT OF BEGINNING. CONTAINS 0.897 ACRES, MORE OR LESS. I�JQirr A I +�t11� rljr�x� S Nov u 4j, Z y/�"�'✓r�w�l �/JN.t !� ityilr�, �Gu✓,� l�uir� SANFORD FIRE DEPARTMENT THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. AN ISSUED PERMIT SHALL BE DEEMED PERMISSION TO PROCEED WITH WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THESE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE FIRE PREVENTION DIVISION FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS ON THE PLANS, CONSTRUCTION OR OTHER VIOLATIONS OF THE CODE. c" o a E C3 cV N q qp U W c+7 di Uj� o0 3K.Itff ia • z Qx3 J2A. 0o�Q3 weeks o ;" W in� CIVIL ENGINEERING W « Q CERTIFICATE OF AUTHORIZATION No.: 9230 NO. REVISION BY DATE 1 Owner Revisions RZ 03.28.18 2 City Comments DB o6.05.18 3 Owner Revisions DB 09.14.18 4 OFFICE REVIEWED BY: MATT MINNIE SANFORD FIRE L EPT. DATE: (:0'V - r 1018 PERMIT # /C,7 rO �.�. •••••...,nor r�s ��� • 1L . 'LC�'PJSF''' �. co rncoA No CQ rI 1 'n• sn NPS C o00 Lnt 1, WA[_.---NIART "Fi c'st H, !..ay" b!_aildil`ig SL)PERSTORE ON RINEI--iAR'T ROAD Fiat Book 65, Pcges 31---32 "concretesidewalk i �• edge b( WC]tCl, concrete elev. 33.536.45 i - I xedcJe of water, concrete �! edge of water aspho!t�~~' driveway, k X I D '� r I � rj „ re of water � 12 C900 DR -18 PVC WATER MAIN J 42.76 concrete retaining weal! ed elev. 36 Z A13.42_ (i `/V) X4'.2 1 'r x/ __._._..._._�. —_ ------ e. y 1 19 OAK7 . OAK7 — 1 �� CORP STOP � T. .�...�. ___^._ .. _........ �-----_ __..__.:.._-.----=--==-----� 4�- ;$ — Q OAK14 1- Q — 4:=. 5 'ill PYLP n CYP�-c�—OCYR$ --C3— CD CYP�CY-�80 CYP6 O�Yi~' '`n rvp� p�AK�1� ,g OA K26 — --C ------- - �o�� �`. 1�� RESILIENT WEDGE GATE VALVE _— O-- ----- �_B -CY-p --- -CYP6- --- �� ----- ----------------- - — — I — T — _ 1 POLYETHYLENE SERVICE — 12"X6" TEE — — — — 2 — — _ — — — — 1 C900`R=18 PVC WATER MAIN — — � I 6 GATE VALVE 12 X8 TEE 2 SCHEDULE 40 12 X8 TEE PROPOSED PRIVATE UTILITY "� 1 I 2" TEE 12" GATE VALVE r — I W PVC RE -USE LINE — — — — — — — — 12 GATE VALVE — — -- — — — —AND ACCESS EASEMENT — — -- -- — — 2 GATE VALVE — — — — — — — — — — — — — — — J L _ -12"X6" REDUCER- — — --t I — — — — — — — '8 GATE V LVE ' — — — — — — — 8 GATE VALVE S1 A -1 � 273 LF.- 8 PVC ®0.50% �— ---- --- - '� 198 LF.- 8 PVC 0 0.50/ 45 LF. - 8" LATERAL 6" C900 DR -18 PVC WATER MAIN SM -2 8"X 6" TEE PVC 0 0.50% CONNECTION s " 2" SCHEDULE 40 0OAK6 I I I 6 MJ CAP PVC RE -USE LINE OOAK6 I I 8" MJ CAP FIRE HYDRANT ASSEMBLY —I 4" C900 DR -18 I L — — J8" PVC CAP 2 . < .... . CA 13V FORC • . . 8" MJ CAP PVC 0 1.00% 2" SCHEDULE 40 PVC — — — — — — I RECLAIMED WATER o GE I I 2" GATE VALVE SANITARY LIFT STATION (REFER TO IRRIGATION TOP EL.- 45.45 I 4" GATE VALVE AND INV.- 37.50 I 4" MJ CAP (FUTURE HOTEL r� I PLANS FOR CONTINUATION) REFER TO SHEET C900 I I I CONNECTION) f o r t. O 1-1 o f 1_ o f I FOR DETAILS � ., I I V l_.__ L__ A K L__ ) F�\ 0 S �4� I� OPALM14 45 K 1 REDUCED PRESSURE LIFT STATION BACKUP GENERATOR P I I BACKFLOW PREVENTER __ TO BE INSTALLED WITH HOTEL I I AND HOSE BIB '..^�, B. CIS-� DEVELOPMENT. I I I I OOAK12 I I I 36.41 D-7 36.41 I Z.50 0 I - 6" DOUBLE DETECTOR CHECK VALVE ASSEMBLY W/TAMPER SWITCH X (MONITORED AND 4" FIRE DEPARTMENT CONNECTION (PRIVATE). D-- 8 ] x X (POINT OF SERVICE IS FIRST OS&Y VALVE) _P4NQ_Q- X yr �1 _ . .. .. _ 1 �.� i .irui I uiir. irii�.c �% T� AfE� Er- — — — — n — — C� OAK 5— — — — — — — — - ----- 11=OAK15----- ------------- -------GGAlE6----------- 7-1 2" POLYETHYLENE WATER SERVICE GRAPHIC SCALE 30 0 15 30 60 (1 IN.= 30 FEET) X 38.59 , 2"X11 . V V 1 . 1" REDUCER - 6" C900 DR! -14 PVC WATER S 15 LF.� 6" PVC 0 1.00% MIN. PRpPSED a5' pRIVAT>M 18' FZCP WATI ' 0NI= LA�EM�NI inv It =- . I I /I � I rc';tairiing wall I I drainage inlet ,- to') elev, 39.-5 TE inv. = 33.73' I I I I I I X 41.87X 43.9A E��_q Nlwl� 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 X Telephone 407.478.8750 Facsimile 407.478.8749 Certificate of Authorization No.: 9230 `,�r� ,,t G • VV,� � , �i . w . ' + , Cir to Selby G. Weeks 56991 0 0 39.28 1-1 AtJUVt I ht uu i JIUt ur IML V I NLm rlrLIL111t. ~ I C. AT THE UTILITY CROSSINGS DESCRIBED IN PARAGRAPHS (A) AND (B) ABOVE, ONE FULL SM -3 SANITARY MANHOLE LENGTH OF WATER MAIN PIPE SHALL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE TOP EL.= 44.45 0 E. INV.= 40.130 SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHER PIPELINE. A W. INV.= 40.03 LTERNATIVELY, AT SUCH CROSSINGS, THE PIPES SHALL BE ARRANGED SO THAT ALL WATER ( J �\ w MAIN JOINTS ARE AT LEAST THREE (3) FEET FROM ALL JOINTS IN VACUUM—TYPE SANITARY SEWERS, STORM SEWERS, STORMWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER AND AT LEAST SIX (6) FEET FROM ALL JOINTS IN GRAVITY OR PRESSURE—TYPE 8.35 f, \ Z SANITARY SEWERS, WASTEWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610 F.A.C. 3. ALL ON UTILITIES SHALL BE PRIVATELY OWNED AND MAINTAINED. N INT SHALL BE AS DESCRIBED IN THE FDEP PERMIT CONDITIONS. Storm drain mars7olc �� En 4. BACTERIOLOGICAL SAMPLE POINTS 5. CONTRACTOR SHALL NOTIFY THE CITY OF SANFORD UTILITIES DEPARTMENT 48 BUSINESS HOURS PRIOR TO ANY UTILITIES CONSTRUCTION. 6. ALL UNDERGROUND FIRE MAINS SHALL BE INSTALLED IN ACCORDANCE WITH NEPA 24, 2007 EDITION, .o "STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES [F.A.C. 69A-60.005 (2)]. 6i 0 Filename : C500 — C501 Utility Plans— Rinehart Commons PHt.dwg Plot Date : Sep. 20, 2018 10:09am top elev. = /1-8,35 S invert 40.10' (18" Rr P" N Invert = 39.82' (18" RCp) 147.49 me Co revision description 0 0 8 0 Owner Revision 03.28.18 City Comments 06.05.18 Owner Revision 09.14.18 drawn by: RVZ checked by: SGW date: 03/09/18 Q) plot scale: AS S110WN !l project number: 17PINEoo1 file name: x -36x 74 Title Blk - Rinchan.dwg I /I � I rc';tairiing wall I I drainage inlet ,- to') elev, 39.-5 TE inv. = 33.73' I I I I I I X 41.87X 43.9A E��_q Nlwl� 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 X Telephone 407.478.8750 Facsimile 407.478.8749 Certificate of Authorization No.: 9230 `,�r� ,,t G • VV,� � , �i . w . ' + , Cir to Selby G. Weeks 56991 0 0 39.28 1-1 AtJUVt I ht uu i JIUt ur IML V I NLm rlrLIL111t. ~ I C. AT THE UTILITY CROSSINGS DESCRIBED IN PARAGRAPHS (A) AND (B) ABOVE, ONE FULL SM -3 SANITARY MANHOLE LENGTH OF WATER MAIN PIPE SHALL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE TOP EL.= 44.45 0 E. INV.= 40.130 SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHER PIPELINE. A W. INV.= 40.03 LTERNATIVELY, AT SUCH CROSSINGS, THE PIPES SHALL BE ARRANGED SO THAT ALL WATER ( J �\ w MAIN JOINTS ARE AT LEAST THREE (3) FEET FROM ALL JOINTS IN VACUUM—TYPE SANITARY SEWERS, STORM SEWERS, STORMWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER AND AT LEAST SIX (6) FEET FROM ALL JOINTS IN GRAVITY OR PRESSURE—TYPE 8.35 f, \ Z SANITARY SEWERS, WASTEWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610 F.A.C. 3. ALL ON UTILITIES SHALL BE PRIVATELY OWNED AND MAINTAINED. N INT SHALL BE AS DESCRIBED IN THE FDEP PERMIT CONDITIONS. Storm drain mars7olc �� En 4. BACTERIOLOGICAL SAMPLE POINTS 5. CONTRACTOR SHALL NOTIFY THE CITY OF SANFORD UTILITIES DEPARTMENT 48 BUSINESS HOURS PRIOR TO ANY UTILITIES CONSTRUCTION. 6. ALL UNDERGROUND FIRE MAINS SHALL BE INSTALLED IN ACCORDANCE WITH NEPA 24, 2007 EDITION, .o "STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES [F.A.C. 69A-60.005 (2)]. 6i 0 Filename : C500 — C501 Utility Plans— Rinehart Commons PHt.dwg Plot Date : Sep. 20, 2018 10:09am top elev. = /1-8,35 S invert 40.10' (18" Rr P" N Invert = 39.82' (18" RCp) 147.49 me Co revision description 0 0 8 0 Owner Revision 03.28.18 City Comments 06.05.18 Owner Revision 09.14.18 drawn by: RVZ checked by: SGW date: 03/09/18 --- plot scale: AS S110WN !l project number: 17PINEoo1 file name: x -36x 74 Title Blk - Rinchan.dwg .Al EXISTING 12" DI WATER MAIN WET TAP EXISTING 12" DI WATER MAIN W/ 12"X 12" MJ TAPPING VALVE AND SLEEVE WET TAP EXISTING 12" PVC RECLAIMED MAIN W/ 12"X 4" MJ TAPPING VALVE AND SLEEVE EXISTING 12" PVC RECLAIMED MAIN EXISTING 0.25" COMMUNK EXISTING 4.5" E EXISTING 2.5" WET TAP EXISTING 12 W/ 12" TAPPING VAI EXISTING 12" P E) RE-( t:� ill n n> I I 2" C900 - DR -18 WA ER IM�IN STA. ~ 4'00 (�> I� BORE AND JACK REE TO ' I ° PROFILE AND DETAIL T I SH Yd , pavennent stamped # 065370 ii 1� I... Olt 1 BES I BUY ON RINE-J-IAF� i F�OAD Play Book 66, ('ages 49---50 6'X2"TEE i I � i i i � i II 2" RESILIENT (WEDGE GATE VALVE Tt a _ _ J 1 �DO�'LE ETE TORI I i J� i/ r ; I CHECK VALVE ASSEMBLY Q 2" POLYETHYLENE WATER SERVICE t12"X6" TEE AND'' 1" METER c W h 09X 95.35 45.05 X 1 6 GATE VALVE 1.5 REDUCED PRESSURE BACKFLOW PREVENTER ---ed c of , PROPOSED 20 PRIVATE rb e -- UTILITY EASEMENT 20' -WIDE PUBLIC _ — — — — — _ — — — — — REDUCER 8 OOA 10 UTILIT`f„EA�EME�NTOAK15 C)OAK13 OOAK10 _ UO 12 OAK11 COMAG6 -- `-DIRECTIONAL DRILL 2” CARRIER 12" C900 DR -1 PVC W — INSIDE CASING (DRILL TOGETHER) - s NOTE: 2" RECLAIM LINE SHALL BE I I ' r — — — — — c� — _4" C900 DR -18 PVC FORCE MAIN— — — NO GREATER THAN 12 FT DEEP•�7��' -f- __ .r, I I I ,: WITH MINIMUM DEPTH OF 4.5 FT.;P) � I � � I � - "1 I 4" MJ CAP(S) WET •TAP EXISTING 6" PVC FORCE MAIN I I -- ` �., ; , I — -LEAVE ROOM FOR FUTURE 2" METER AND — Mg W/8"X4" MJ TAPPING VALVE AND SLEEVE. I 3" REDUCED PRESSURE BACKFLOW PREVENTER s VALVE SET IN HORIZONTAL POSITION) 9 ` - 6 6"X4" TEE c e )� EXISTING 8" PVC I end ` 4.: GATE VALVE orner y-' I SANITARY FORCE MAIN I =�j I I 6" GATE VALVE AND 47.21 _ r• �' 11 Lit 4" PLUG VALVEJ I I I 6" MJ CAP y _ I I 2" RESILIENT WEDGE GATE VALVE At 4- I I I I I I 2 (IRRIGATION MET R, \ . ^va 47.09 ` ^ii.04¢ I I I rn I j I — 1x.47' R 2 , C f I I I III I r� n� — /11 -0 -) i0 -- I>> n) ATN I LE r7 CJ >U � �.. � 87,67) � �Ii � I I ►vl -� V I I I � s� I i I 0I � LI W I I I I > I I 0 OAK12 I I 0 Q I I ,, I I 0Cr l y li I I I E7D � �� _0I � I Q) C_ 'a o 01, � C� I O Q. �j I I I ��_.�I I I I X 44.72 X 4 4.15 -- --- 6 ----- o +-9t 2" SCHEDULE 40 PVC RE -USE LINE - 4" C900 DR -18 PVC WATER HT1 i, P i n,e L c \\ iUUA Grove Plat , 235 LF. -8" PVC 0 0.50% l 8" PVC CAP, INV.= 38.761771 /3 it 0o _�Ij� I ,Eq t R/W line .--. Northerly I.._/A I I I r��l _/ RR�UV I i n e J ��a C_'l I I I i — �----- _ _-----PA12i112 — —�— — — — — I -a v I JN Lt.... I j � ----- — --------- n [;� Q) X I ' XA X X X X X X --- �� II J °'" �'� V)I .� � I i I (1 1 \ I 6 high chair, link fence N 900000� I I ------------------------- X X x X X ;x'— 530. 4 cr '� j - - Recovered 5/8" iron XI I `- rc7d witi � no cap I - F Q- �IE fence corner is 3.5 \ -(D I-) I CJ I I -- south and 1.5' west _ X 4.3 4 �`• �� rr> X 49.48 X 49,34 drainage manhole _I.op elev. = 47.89' N invert 7n 39.79' (18" RC;III) S'Jv` invert =- 43.27' (18" RCF') - I Site C3enchmark Wf:;st line of Section 33 -�Recovered Seminole County nail and disk stamped 81,5-53-03 in concrete median top elevation = 53.32' I RINEHART ROAD — BORING AND JACKING PROFILE X 48.4.1 12" PVC C900 DR -18 WATER MAIN. REFER TO PLAN VIEW THIS SHEET FOR CONTINUATION. Al X 48.58 WEST TO EAST 1"= 20' HORIZONTAL 1"= 5' VERTICAL ZI nienume : wuv — Vwi uunLy nunb— IUIIOIIUI l wnnnunz- rni.u"y nut vine . xN. cu, tutu IV, ivuni GRAPHIC SCALE 3o 0 15 so (1 IN.= 30 FEET) FINISHED GRADE CONCRETE BLOCK OR BRICK AND (SEE NOTE 2) MORTAR WALL FILLING AT BOTH ENDS VENT HOLE RESTRAINED JOINT DUCTILE — — IRON PIPE 4" MIN. 6" MIN. STEEL CASING PIPE DUCTILE IRON PIPE 36" MIN. COVER CASCADE TYPE CASING SPACER NOTES: 1. WHEN CONSTRUCTION IS WITHIN FDOT JURISDICTION, ADDITIONAL REQUIREMENTS OF THE UTILITY ACCOMODATION GUIDE SHALL BE M ET. 2. WHERE PRACTICAL, CASING SHALL EXTEND 10 FEET BEYOND EDGE OF PAVEMENT AND SHALL NOT BE LESS THAN 6 FEET BEYOND EDGE OF PAVEMENT IN ANY CASE. THE CITY MAY REQUIRE LONGER CASING FOR DEEPER BORES. 3. AS A CONDITIONAL ALTERNATE SPACER METHOD, FOUR -4 FOOT LONG, 4 INCH BY 4 INCH PRESSURE TREATED WOOD SKIDS, WHICH ARE NOTCHED FOR THE USE OF ONE INCH WIDE STAINLESS STEEL BANDS, HAVE A BEVELED LEADING EDGE, AND ARE PLACED 90 DEGREES TO EACH OTHER AROUND THE PIPES, MAY BE USED ON A CASE BY CASE BASIS AS SPECIFICALLY APPROVED IN WRITING BY THE DIRECTOR. SLIPPAGE OF THE SKIDS WILL RESULT IN THE REQUIRED USE OF CASCADE TYPE CASING SPACERS. BORING AND JACKING DETAIL CITY OF SANFORD FIG. 106 An C4013Z tk LU lift cl" SU Z Z au U 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Certificate of Authorization No.: 923o G. — • 1.-r _.� • a;a•• r- • �`� • �GRI01' Selby G. Weeks 56991 revision 0 6 0 A 0 description date Owner Revision 03.28.18 City Comments 06.05.18 Owner Revision 09.14.18 drawn by: RVZ checked by: SGW date: 03/09/18 plot scale: AS SHOWN project number: 17RTNEool file name: XJ6x 74 Title Blk- Ri¢ahart.dwg SQUARE CUT EDGE OF EXISTING PAVMENT (TYP.) FINISHED GRADE TRENCH WIDTH VARIES SEE NOTE 10 9 0- W/ SIZE OF PIPE L 2" MIN. ASPHALTIC CONIC. TRENCH WIDTH VARIES NMI M3LYM DRRIViDitl _J $„ WHEN FLEXIBLE PAVEMENT PAYMENT (TYP.) � 4„ L, E.4 y IS CUT. RECI.AWD WATER MAIN REIMA; D WATE71 WN D Y 43 SEE NOTE 2 ANGLE MAY VARY 6o \ a m 0 T2' i i 14 V W \/ SEE NOTE 4 \� \ PIPE O.D. * MIN. ASPHALTIC CONIC. s ~ 12 WHEN FLEXIBLE PAVEMENT N �^ 1 1-1 /4' BEND y� 4 IS CUT 6 Ts v W SEE NOTE 2 6" (TYP) ANGLE MAY VARY OR BRANCH EOFTEE SELECT 0° z .. r 136 COMMON U Wa ` FILL / /� Ld z 0 0 / * PIPE O.D .� m ~ !1a6R 0o0o BEDDING ROCK a y Q ,. » 6 (TVP)imlSELECT PIPE BEDDING \ 2o° o 0 0 0 -o oo�� (SEE NOTE 8 & 9) �\ UNDISTURBED NOTES: \ \ , \ EARTH 1. PIPE BEDDING: SELECT COMMON FILL COMPACTED TO 95% OF THE MAXIMUM DENSITY AS PER AASHTO T-180. 2. TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% OF THE MAXIMUM DENSITY AS PER AASHTO T-180. FLOWABLE FILL, 100-125 P.S.L. SHALL BE USED WHERE EXISTING PAVED AREAS ARE AFFECTED. SEE SECTION 32.8.4 OF UTILITY MANUAL FOR DESIGN MIX. 3. USE OF TYPE A BEDDING TO BE DETERMINED IN THE FIELD AS DIRECTED BY THE CITY. 4. 15" MAX. FOR PIPE DIAMETER LESS THAN 24", AND 24" MAX. FOR PIPE DIAMETER 24" AND LARGER. THE MINIMUM DISTANCE SHALL EQUAL THE OUTSIDE DIAMETER OF THE PIPE. 5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION. 6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE FLOW. 7. REFER TO SECTION 32.5 OF THE MANUAL FOR SHEETING AND BRACING IN EXCAVATIONS. SHALL COMPLY WITH STATE OF FLORIDA TRENCH SAFETY ACT. 8. GRAVITY SEWERS SHALL UTILIZE TYPE A BEDDING IF REQUIRED BY THE CITY. BEDDING DEPTH SHALL BE 4" MINIMUM FOR PIPE DIAMETER LESS THAN 15" AND 6" MINIMUM FOR PIPE DIAMETER 16" AND LARGER. 9. DEPTH FOR REMOVAL OF UNSUITABLE MATERIAL SHALL GOVERN DEPTH OF BEDDING ROCK BELOW THE PIPE. THE CITY SHALL DETERMINE IN THE FIELD IF REMOVAL OF UNSUITABLE MATERIAL IS REQUIRED TO REACH A SUITABLE FOUNDATION. 10. ALL UNPAVED DISTURBED AREAS SHALL BE SODDED TO MATCH ADJACENT DOMINATE GRASS SPECIES. 11. FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE. REGULATIONS OF GOVERNING AGENCIES. SURFACE RESTORATION WITHIN CITY RIGHT-OF-WAY. SHALL COMPLY WITH REQUIREMENTS OF RIGHT-OF-WAY UTILIZATION REGULATIONS. TYPE A BEDDING AND OPEN -CUT DETAIL CITY OF SANFORD 1999 FIG. 100 PVC PIPE COLORS GRAVITY SEWER: SOLID LIGHT GREEN FORCE MAIN: SOLID LIGHT GREEN ; TYPICAL PIPE 4" TO 8" PIPE - 6" TAPE IS CENTERED ALONG TOP HALF OF PIPE. SEWER LINE SEWER LINE 10" TO 18" PIPE - 6"TAPE IS PLACED ALONG BOTH SIDES OF TOP HALF OF PIPE. i 3Nn 113M3S 3NI1 113M3S 3NI1 B3M3S ' SEWER LINE SEWER LINE SEWER LINE 20" AND LARGER PIPE - TAPE IS PLACED ON BOTH SIDES OF THE TOP HALF OF THE PIPE WITH A THIRD STRIP CENTERED ALONG TOP HALF OF PIPE. �y.If/I1IY/V/1IYI0I/1N/V/1,R/IV/1/Y/V!/N�/IJRH/f/ YAW.... . 'r�j� H/VO/Y/V��//HOHNOIY/VO/YNOH//.ON/VO� /HO/Y/f/ONH!!/Y/f/O/. FOR SEWER LINES - TAPE SHALL BE GREEN WITH BLACK LETTERING. -� FOR SEWER FORCE MAIN - TAPE SHALL BE BROWN WITH BLACK LETTERING. TAPE SHALL RUN FROM JOINT TO JOINT ALONG THE LENGTH OF THE PIPE. ALL FORCE MAINS AND DUCTILE IRON GRAVITY LINES WITH IDENTIFICATION TAPE NTS 6" PIPE IDENTIFICATION (SEWER - FORCE MAIN AND GRAVITY) CITY OF SANFORD 1999 FIG. 108 Fii�nCme � 600 - C900 SITE DE:TAILS.t:irod Plol Date : Sep. 19, 201$ 10:15am SQUARE CUT EDGE OF EXISTING ' / NMI M31YM ORMYI�Otl TRENCH WIDTH VARIES NMI M3LYM DRRIViDitl SEE NOTE 9 $„ 10„ PAYMENT (TYP.) � 4„ W/ SIZE OF PIPE � $„ RECLAIMED WATER MAIN RECI.AWD WATER MAIN REIMA; D WATE71 WN FINISHED GRADE 43 51 6o RECLAIMED WATER MAN RECWMED WATER MAIN T2' i i 14 18 22 25 \ \ 22-1/2• BENDcj MIN. ASPHALTIC CONIC. / _J 12 WHEN FLEXIBLE PAVEMENT / �^ 1 1-1 /4' BEND y� 4 IS CUT 6 Ts v W SEE NOTE 2 ANGLE MAY VARY OR BRANCH EOFTEE 52 0° z :x r\\\� 136 U Wa SEE NOTE 4 / / /� Ld W x g / * PIPE O.D .� ~ 0 �T / \ » 6 (TVP)imlSELECT CO N \/ COMMONW o 0 FILL UNDISTURBED W IL W EARTH IL .. (SEE NOTE 3) nvl\ / \ NOTES: 1. PIPE BEDDING: SELECT COMMON FILL COMPACTED TO 95% OF THE MAXIMUM DENSITY AS PER AASHTO T-180. 2. TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% OF THE MAXIMUM DENSITY AS PER AASHTO T-180. FLOWABLE FILL, 100-125 P.S.I., SHALL BE USED WHERE EXISTING PAVED AREAS ARE AFFECTED. SEE SECTION 32.8.4 OF UTILITIES MANUAL FOR DESIGN MIX. 3. PIPE BEDDING UTILIZING SELECT COMMON FILL OR BEDDING ROCK IN ACCORDANCE WITH TYPE A BEDDING AND TRENCHING DETAIL MAY BE REQUIRED AS DIRECTED BY THE CITY. 4. 15" MAX. FOR PIPE DIAMETERS LESS THAN 24", AND 24" FOR PIPE DIAMETER 24" AND LARGER. THE MINIMUM DISTANCE SHALL EQUAL THE OUTSIDE DIAMETER OF THE PIPE. 5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION. 6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE FLOW. 7. REFER TO SECTION 32.5 OF THE MANUAL FOR SHEETING AND BRACING IN EXCAVATIONS. SHALL COMPLY WITH STATE OF FLORIDA TRENCH SAFETY ACT. 8. FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS OF GOVERNING AGENCIES. SURFACE RESTORATION WITHIN CITY RIGHT-OF-WAY SHALL COMPLY WITH REQUIREMENTS OF RIGHT-OF-WAY UTILIZATION REGULATIONS. 9. ALL UNPAVED DISTURBED AREAS SHALL BE SODDED TO MATCH ADJACENT DOMINATE GRASS SPECIES. TYPE B BEDDING AND OPEN -CUT DETAIL CITY OF SANFORD 1999 FIG. 101 PVC PIPE COLOR PANTONE PURPLE 522C TYPICAL PIPE 2" TO 8" PIPE - 6" TAPE IS CENTERED ALONG TOP HALF OF PIPE.\ / RECLAIMED WATER MAIN RECLAIMED WATER MAIN 10" TO 18" PIPE - 6" TAPE IS PLACED ALONG BOTH SIDES OF THE TOP HALF OF PIPE. % NMI -Al m11R:= NMI IBM 43 M S NIYN R31YM a2reno R 1 R[CWAIEb WATER WIN RECUMED WATER IMM W RECMED WATER MAIN 20" AND LARGER PIPE - TAPE IS PLACED ON BOTH SIDES OF TOP HALF OF PIPE WITH A THIRD STRIP CENTERED ALONG TOP HALF OF PIPE.-----%. PAPER BACKED ADHESIVE VINYL TAPE (TYPICAL) MAX. IT WATER RECUWED WATER WI11= 1 " WCIAMED WATER WIN 1 16 INCHES IMPREGNATED LETTERING SHALL BE USED. THE TAPE SHALL RUNS FROM JOINT TO JOINT ALONG THE LENGTH OF THE PIPE. RECLAIMED WATER MAINS WITH IDENTIFICATION TAPE NTS PIPE IDENTIFICATION (RECLAIMED WATER) CITY OF SANFORD 1999 FIG. 109 MINIMUM LENGTH (FT) TO BE RESTRAINED ON EACH SIDE OF FITTING(S). * ' / NMI M31YM ORMYI�Otl NIYN M,AYM D3RIYIDitl NMI M3LYM DRRIViDitl ' / $„ 10„ 12„ � 4„ 16„ � $„ RECLAIMED WATER MAIN RECI.AWD WATER MAIN REIMA; D WATE71 WN ,/ 43 51 6o RECLAIMED WATER MAN RECWMED WATER MAIN R[CWM[D WATER MAIN i PAPER BACKED ADHESIVE VINYL TAPE (TYPICAL) MAX. IT WATER RECUWED WATER WI11= 1 " WCIAMED WATER WIN 1 16 INCHES IMPREGNATED LETTERING SHALL BE USED. THE TAPE SHALL RUNS FROM JOINT TO JOINT ALONG THE LENGTH OF THE PIPE. RECLAIMED WATER MAINS WITH IDENTIFICATION TAPE NTS PIPE IDENTIFICATION (RECLAIMED WATER) CITY OF SANFORD 1999 FIG. 109 MINIMUM LENGTH (FT) TO BE RESTRAINED ON EACH SIDE OF FITTING(S). * PVC:C-900/905 PIPE SIZE 4„ 6„ $„ 10„ 12„ � 4„ 16„ � $„ 209$ 249$ 90' BEND 2433 43 51 6o 45• BEND 10 14 18 22 25 22-1/2• BENDcj 7 9 11 12 1 1-1 /4' BEND 3 4 5 6 6 OR BRANCH EOFTEE 52 74 96 115 136 NOTES: 1. FITTINGS SHALL BE RESTRAINED JOINT TYPE. 2. INSTALL FULL LENGTHS OF PIPE WITH TOTAL LENGTH CONTAINING ONLY RESTRAINED JOINTS EQUAL TO OR GREATER THAN LENGTH SHOWN IN TABLE. 3. WHERE TWO OR MORE FITTINGS ARE TOGETHER, USE FITTING WHICH YIELDS GREATEST LENGTH OF RESTRAINED PIPE. 4. IN LINE VALVES AND THROUGH RUN OF TEES OUTSIDE LIMITS OF RESTRAINED JOINTS FROM OTHER FITTINGS NEED NOT BE RESTRAINED UNLESS OTHERWISE INDICATED. 5. LENGTHS SHOWN IN THE TABLE HAVE BEEN CALCULATED IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN "THRUST RESTRAINT DESIGN FOR DUCTILE IRON PIPE" AS PUBLISHED BY DIPRA, WITH THE FOLLOWING ASSUMPTIONS: * TYPE OF PIPE:____ PVC * WORKING PRESSURE:_ id0 ._,__P.S.I. ___________ P.S.I. * SOIL DESIGNATION:___SM___ * LAYING CONDITIONS:_____ * TO BE COMPLETED BY THE ENGINEER * THIS TABLE IS FOR DOMESTIC WATER ONLY. REFER TO FIRE PROTECTION SPECIFICATIONS FOR FIRE LINE RESTRAINT REQUIREMENTS (RESTRAIN ALL JOINTS UNLESS OTHERWISE NOTED). RESTRAINED PIPE TABLE ( PVC -HDPE CITY OF SANFORD 1999 FIG. 104A PVC PIPE COLOR WATER MAIN: BLUE 2" TO 8" PIPE - 6" TAPE IS CENTERED ALONG TOP HALF OF PIPE. 0/1 POTABLE WATER MAIN TYPICAL PIPE POTABLE WATER MAIN 10" TO 18" PIPE - 6" TAPE IS PLACED ALONG BOTH SIDES OF TOP HALF OF PIPE. NIYN 1131YM 318Y1Od NM1'1 1131YM 318Y10d NIYN S31YM 318tl`1,Od POTABLE WATER MAIN POTABLE WATER MAIN POTABLE WATER MAIN 20" AND LARGER PIPE - TAPE IS PLACED ON BOTH SIDES OF THE TOP HALF OF THE PIPE WITH A THIRD STRIP CENTERED ALONG TOP HALF OF PIPE. NIYN N31YM 318Y1Od NIYN B31YM 318Y1Od NIYN H31VM 318Y1Od ' POTABLE WATER MAIN POTABLE WATER MAIN POTABLE WATER MAIN / POTABLE WATER MAIN POTABLE WATER MAIN POTABLE WATER MAIN PAPER BACKED ADHESIVE TAPE (TYPICAL) �- 12" ~� ER MAIN MAX. POTABLE WATER MAIN 1" POTABLE WATER MAIN 6 INCHES BLUE TAPE WITH BLACK PERMANENTLY IMPREGNATED LETTERING SHALL BE USED. THE TAPE SHALL RUN FROM JOINT TO JOINT ALONG THE PIPE. POTABLE WATER MAIN WITH IDENTIFICATION TAPE NTS PIPE IDENTIFICATION (POTABLE WATER) CITY OF SANFORD 1999 FIG. 110 30" x 30" x6" TK. CONC. PAD (FLUSH WITH FINISHED GRADE) 3" DIA. BRONZE DISC ANCHORED IN CONC. PAD STAMP AS REQ'D. SIZE OF VALVE TYPE OF VALVE SERVICE DIRECTION & NO. TURNS TO OPEN APPLICABLE VALVE BOX AND COVER (SEE FIG. 115) 3000 P.S.I. CONC. MIN. #4 REBARS- ALL AROUND APPLICABLE VALVE BOX AND COVER (SEE FIG. 115) #4 REBARS ALL AROUND- . . d !'A. ° ° ` . d a ov • v •4 Ad• A.dd WATER dl° A d 4e as °.. I_ w 3" DIA. BRONZE 2" TK. DISC ANCHORED IN CONC. PAD -STAMP AS - REQ'D. 2I I A A N Q. Cfl A A A.° : .G. . ° . • A • a 44 \ \. IPA -_ 2" MIN. VALVES 16 INCHES AND LARGER ANCHORS (TO BE APPROVED BY CITY) 6" TK. CONC. PAD (FLUSH WITH FINISHED GRADE) VALVES SMALLER THAN 16 INCHES VALVE BOX PAD DETAIL CITY OF SANFORD 1999 FIG. 107 GROUND LEVEL 18" VINYL CONTINUOUS ARNING TAPE GENERAL NOTES: A. ALL UTILITY PIPES SHALL BE INSTALLED WITH 6 INCH WIDE VINYL CONTINUOUS NON- METALLIC TAPE, FOR IDENTIFICATION AND WARNING PURPOSES, BURIED ABOVE THE PIPE AT A MAXIMUM DEPTH DEPTH OF 18 INCHES OR AS APPROVED BY THE CITY. IT SHALL BE COLOR CODED AND WORDED AS FOLLOWS: 1. POTABLE WATER 3. GRAVITY SEWER A. COLOR: BLUE WITH BLACK LETTERING. A. COLOR: GREEN WITH BLACK LETTERING. B. LETTERING: "CAUTION: WATER LINE B. LETTERING: "CAUTION: SEWER LINE BURIED BELOW" OR SIMILAR WORDING. BURIED BELOW" OR SIMILAR WORDING. 2. RECLAIMED WATER 4. SEWER FORCE MAIN A. COLOR -PURPLE WITH BLACK LETTERING. A. COLOR: BROWN WITH BLACK LETTERING. B. LETTERING: "CAUTION: RECLAIMED WATER B. LETTERING: "CAUTION: SEWER FORCE LINE BURIED BELOW" OR SIMILAR MAIN BURIED BELOW" OR SIMILAR WORDING. WORDING. B. 10 GAUGE SOILD COPPER WIRE W/600V INSULATOR, CONTINUOUS COLOR SHALL BE INSTALLED ALONG ALL PRESSURIZED MAINS. USE PRE -FILLED DRI --SPLICE WIRE CONNECTORS W/CRIMP SLEEVE FOR ALL WIRE SPLICING, (SPEARS DE -400 or APPROVED EQUAL), THE WIRE SHALL BE LOOPED AND TIED TO ALL VALVE BOXES, (SEE FIG. 400). UTILITY PIPE WARNING TAPE (SEWER, POTABLE WATER, AND RECLAIMED WATER) CITY OF SANFORD 2014-9 FIG. 111 z o[ LU w z Q) z W > U 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Certificate of Authorization No.: 9230 0 ( i ' - w - hlo. � , r.� e,l ...��, • r 0 V v RIC)p'. I ,AL V_V �,N Selby G. Weeks 56991 revision description date Q Owner Revision 03.28.18 date: City Comments 06.05.18 plot scale: Owner Revision 09.14.18 0 17RINEool 0 X-36,24 Dife DR - Rm hwl dwg A drawn by: RVZ checked by: SGW date: 03/09/18 plot scale: AS SHOWN project number: 17RINEool file name: X-36,24 Dife DR - Rm hwl dwg I LOT LINE 5' MAX. SERVICE CLEAN-OUT (SEE NOTE 2) WYE WITH RODS ON D.I.P. RISER (TYP) 6" BRANCH �-TERMINAL DEPTH PIPE AND FITTINGS OR DOUBLE CHECK OR SEWER MAIN AS REQUIRED FOR REDUCED SIZE VARIES SERVICE (3' MIN.) 6" 45' WYE WITH (nP) BEND 6" BRANCH SERVICE CLEAN-OUT UNION (TYP.) (SEE NOTE 2) REMOVABLE SINGLE DOUBLE PERMANENT PLUG (TYP) PLUG (TYP) SERVICE SERVICE PROFILE LOT W LINE 3TYPICAL LOCATION OF LOCATOR DEVICE 6" 45' • /. BENDI SERVICE CLEAN-OUT PLAN (SEE NOTE 2) FINISHED GRADE ?� % 6" PVC SLOPE TO TERMINAL AT S 0%MIN. (TYP) N SCHEDULE 40 GALVANIZED RODS ON D.I.P. RISER (TYP) checked by: �-TERMINAL DEPTH PIPE AND FITTINGS OR DOUBLE CHECK OR 6" PVC C7(; AS REQUIRED FOR REDUCED 30•T(TYP•NE SERVICE (3' MIN.) AND FITTINGS TERMINAL DEPTH NOTE 1) (nP) AS REQUIRED FOR(SEE SERVICE (3' MIN.) AIN SUPPORT STANDSi UNION (TYP.) TO BE FLUSH WITH SINGLE DOUBLE FINISHED GRADE. SERVICE SERVICE PROFILE NOTES: 1. INVERT OF LATERAL SHALL NOT ENTER SEWER MAIN BELOW SPRING LINE 30" 2. SERVICE CLEAN -OUTS SHALL BE INSTALLED AT TIME OF BUILDING CONSTRUCTION ABOVE BY THE CONTRACTOR. CURB 4" TO 6" 3. CITY APPROVED ELECTRONIC LOCATING DEVICE SHALL BE INSTALLED FINISH' AT THE END OF EACH SERVICE STUB -OUT. 4. RESIDENTIAL SERVICES SHALL BE 4 INCHES & NON-RESIDENTIAL SERVICES SHALL BE 6 INCHES IN DIAMETER AS A MINIMUM. 5. ELECTRONIC LOCATOR DEVICES SHALL BE PLACED ADJACENT TO THE STUBOUT .a' a� FOR EACH SERVICE. (SEE SECTION 43.4 OF THE UTILITIES MANUAL). SANITARY SEWER LATERAL DETAIL CITY OF SANFORD 1999 FIG. 204 SCHEDULE 40 GALVANIZED RODS ON D.I.P. RISER (TYP) checked by: 4" CONCRETE SLAB PIPE AND FITTINGS OR DOUBLE CHECK OR Z SCHEDULE 80 PVC PIPE R REDUCED PRESSURE DEVICE AND FITTINGS 1/2" PREFORMED JOINT METER BOX AND LID UNION SUPPORT STANDSi UNION TO BE FLUSH WITH TO FINISHED GRADE. SHUT OFF VALVE 12" TO 30" i i ABOVE CURB 4" TO 6" GRADE FINISH' GRADE .a' a� METER CURB STOP -*- SERVICE LINE -------- CORP. STOP DOUBLE STRAP SADDLE WATER MAIN NOTES: 1. A POSITIVE DIELECTRIC CONNECTION SHALL BE MADE BETWEEN ALL GALVANIZED AND BRASS COMPONENTS. 2. METER SHALL BE INSTALLED BETWEEN SIDEWALK AND CURB WHERE APPLICABLE, OR AT PROPERTY LINE AND IN NO CASE SHALL IT BE INSTALLED IN SIDEWALK OR OTHER PAVED AREAS. 3. USE PRIMER SUITED TO BASE MATERIALS. FINISH WITH TWO COATS OF BLACK EXTERIOR ENAMEL. DOMESTIC METER AND DOUBLE CHECK VALVE OR REDUCED PRESSURE ZONE ASSEMBLY CITY OF SANFORD 1999 FIG. 503 Filetiorrie : C600 - C900 SITE Df1AILS.dN9 Plot Dote : Sep. 19, 2018 10:16am SET TOP OF VALVE BOX TO FINISHED GRADE FINISHED GRADE---, SEE NOTE 2 RESILIENT SEAT - M. J. GATE VALVE WATER MAIN 1. 10 GAUGE SOILD 2. USE PRE -FILLED COPPER WIRE W/ DRI -SPLICE WIRE 600V INSULATION CONNECTORS W/CRIMP CONTINUOUS COLOR. SLEEVE FOR ALL WIRE SPLICING. (SPEARS DS -'400 or APPROVED EQUAL) CURB F 7 �7- COVER (SEE FIGURE 115) CONCRETE PAD IN UNPAVED AREAS (SEE FIGURE 107) ADJUSTABLE CAST IRON VALVE BOX BOX SHALL REST ON BEDDING ROCK NOT ON VALVE OR PIPE AND SHALL BE CENTERED ON OPERATING NUT 6" BEDDING ROCK NOTES: 1. IF VALVE BOX RISER IS REQUIRED, USE PVC C900 PIPE EXTENSION AND NOTCH RISER FOR TRACER WIRE. 2. THE ACTUATING NUT FOR DEEPER VALVES SHALL BE EXTENDED TO WITHIN 4 FOOT DEPTH BELOW FINISHED GRADE. 3. CONTRACTOR SHALL PROVIDE THE CITY WITH VALVE KEYS IN ACCORDANCE WITH SECTION 52.4 OF THE UTILITIES MANUAL. GATE VALVE AND BOX DETAIL CITY OF SANFORD 2014-9 FIG. 400 SCHEDULE 40 GALVANIZED PIPE AND FITTINGS OR SCHEDULE 80 PVC PIPE AND FITTINGS METER BOX AND LID TO BE FLUSH WITH FINISHED GRADE. SHUT OFF VALVE r 4" TO V" PRESSURE VACUUM BREAKER OR REDUCED PRESSURE DEVICE (NOT REQUIRED WHERE RECLAIMED WATER IS UTILIZED) UNION --� F- UNION 1 12" TO 30" ABOVE { GRADE FINISHE GRADE \_ t METER CURB STOP -+- SERVICE LINE APPLIES ONLY IF IRRIGATION METER HAS SEPARATE TAP TO MAIN. IN MOST CASES --------- CORP. STOP THE IRRIGATION METER WILL BE PARALLEL TO THE HOUSE METER AND OFF OF THE -------- DOUBLE STRAP SADDLE SAME SERVICE CONNECTION. WATER MAIN NOTES: 1. A POSITIVE DIELECTRIC CONNECTION SHALL BE MADE BETWEEN ALL GALVANIZED AND BRASS COMPONENTS. 2. METER SHALL BE INSTALLED BETWEEN SIDEWALK AND CURB WHERE APPLICABLE, OR AT PROPERTY LINE AND IN NO CASE SHALL IT BE INSTALLED IN SIDEWALK OR OTHER PAVED AREAS. 3. USE PRIMER SUITED TO BASE MATERIALS. FINISH WITH TWO COATS OF PURPLE EXTERIOR ENAMEL, 4. DEVICE SHALL BE 12 INCHES (MINIMUM) ABOVE HIGHEST OUTLET. IRRIGATION METER PRESSURE VACUUM BREAKER OR REDUCED PRESSURE ZONE ASSEMBLY CITY OF SANFORD 1999 FIG. 502 HYDRANT -� OPERATING NUT HOSE NOZZLE - 24" SQUARE AND 6" THICK REIN- FORCED CONCRETE SHEAR PAD. (SEE NOTE 2) 2-#4 AT9"- O.C. ALL AROUND COMPACTED BACKFILL SEE NOTE 3 -� AS REQ'D. PUMPER NOZZLE FACING STREET Z X _a a a .0 It r N 6" ;. W 12" MIN. VALVE PAD (SEE FIGURE 107) M J HYDRANT ANCHORING TEE 6" BEDDING ROCK-/ 6" PIPE --J MECHANICAL JOINT RESILIENT SEAT GATE WITH RESTRAINERS VALVE AND BOX (TYP.) (SEE FIGURE 400) NOTES: 1. FIRE HYDRANT SHALL BE SUPPLIED WITHOUT A WEEP HOLE, OR WITH A PERMANENTLY PLUGGED WEEP HOLE. 2. THE DEVELOPER SHALL INSTALL THE SHEAR PAD RECESSED 6 INCHES BELOW THE FINISHED GRADE AND SOD THE RECESSED SECTION. 3. CLEARANCE BETWEEN BOTTOM OF BOLTS AND TOP OF SHEAR PAD SHALL BE A 12 INCH MINIMUM. 4. FIRE HYDRANTS SHALL BE MUELLER A-423, AMERICAN DARLING B-84, KENNEDY K81A OR CLOW MEDALLION F-2545. 5. FIRE HYDRANTS SHALL BE IDENTIFIED IN ACCORDANCE WITH SECTION 52.7.5 OF THE UTILITIES MANUAL. 6. CONTRACTOR SHALL PROVIDE THE THE CITY WITH HYDRANT WRENCHES AND VALVE KEYS IN ACCORDANCE WITH SECTIONS 52.4 AND 52.7.3 OF THE UTILITIES MANUAL. FIRE HYDRANT ASSEMBLY DETAIL CITY OF SANFORD 1999 FIG. 402 CONCRETE STRUCTURE WITH PROPERTY TRAFFIC BEARING COVER LINE LOCKABLE NON SLIP PROPERTY (RIGHT-OF-WAY ACCESS HATCH (ALUMINUM) WIRING FROM PUMP STATION PRESSURE SWITCH 2" BRONZE, BRASS, OR 2" CAP (MIN) BRASS SHUT OF RESILIENT BALL VALVE VALVES AND FIT I GS 2" MIN TEE OIL -FILLED CAST IRON PRESSURE BRASS DRAIN VALVE VALVE BOX GAUGE 2" GROSS 2" MIN DIA PIP BALL CHECK VALVE (FULL FLOW) 2" BRASS HORIZONTAL Y E FLANGED TEE GATE VALVE I INFLOW OUTFLOW FROM PRIVATE TO CITY PUMP STATION I FORCE MAIN FULL FLOW PLUG VALVE MOUNTED DOWNSTREAM WITH 2" SQUARE ACTUATING NUT NOTES 1.THIS DETAIL IS DIAGRAMMATIC ONLY. ARRANGE PIPING TO PROVIDE READY ACCESS TO ALL COMPONENTS. ALL ITEMS SHALL BE RIGIDLY SUPPORTED. 2.DIMENSIONS WILL VARY ACCORDING TO LINE SIZE. MINIMUM SIZE OF BOX SHALL BE 48 INCHES BY 48 INCHES WITH A 24 INCH BY 36 INCH MINIMUM STRUCTURAL ALUMINUM ACCESS HATCH COVER. ALL HARDWARE AND LOCK BRACKETS SHALL BE 304 STAINLESS STEEL. 3.PRESSURE SWITCH SHALL BE ADJUSTABLE WITH THE INITIAL SETTING TO CUT OFF PUMP STATION AT A FORCE MAIN PRESSURE OF 20 P.S.I. THE ON AND OFF PUMP DIFFERENTIAL SHALL BE 10 P.S.I. AND ADJUSTABLE. ALL LETTERS 2' IN HEIGHT 38' I WITH 3/4' SPACING BETWEEN ROWS PRIVATE CONSTRUCT AND INSTALL 1/4` SIGN IN ACCORDANCE WITH (OWNER'S NAME) XA PUMP vION 24• SECTION 22.5.2 OF THE (PHONE NUMBER) HOOO) 000-0 IUTILITIES MANUAL� 1 1/4' 1/2' BORDER --/ FINISH GRADE 1 PRIVATE PUMP STATION PRESSURE SWITCH AND SIGNAGE DETAILS CITY OF SANFORD 1999 FIG. 305 D DOUBLE CHECK OR REDUCED PRESSURE ZONE DETECTOR ASSEMBLY AS APPROVED BY THE CITY - TEST COCK (TYP.) --\ FLANGED 90' BEND (2 REQ.) SLOPE I••-24'- \/ �-' 36" MIN. COVER MAIN 9D BEND (2 REQ.) SERVICE - THRUST COLLAR RODDED TO THRUST COLLAR RODDED TO 90' BEND OR AS REQUIRED 90' BEND OR RESTRAINED BY THE CITY O.S. & Y. RESILIENT SEAT GATE VALVE. (2 REQUIRED) BACK TO VALVE AS REQUIRED BY THE CITY 3 INCH AND ABOVE ASSEMBLY DETECTOR METER BALL VALVE (2 REQUIRED) CONCRETE SLAB DOUBLE CHECK VALVE ASSEMBLY (MINIMUM) 1 1'0" MIN I ABOVE GROUND DEVICE WITH �- 2'0" MIN DETECTOR BYPASS DOUBLE CHECK OR REDUCED PRESSURE ZONE DETECTOR ASSEMBLY CITY OF SANFORD 1999 FIG. 500B 0 Z Lw LU Z Z LUV 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Certificate of Authorization No.: 9230 tlydd��`!, G. o. �.. • 1I- �• .� >A� AL�� ./!Il Selby G. Weeks 56991 ^o F --i r-1 C) W O W W W O 0 f� U ) W revision description date 1L Owner Revision 03.28.18 0 City Comments 06.05.18 Owner Revision 09.14.18 0 0 drawn by: RODS ON D.I.P. RISER (TYP) checked by: 4" CONCRETE SLAB date: WITH NO. 6 x 6 Z W10 x W10 project number: WIRE MESH C ro SLOPE 1/2" PREFORMED JOINT MATERIAL BETWEEN SUPPORT STANDSi PIPE AND CONCRETE SLAB (TYP) TO BACK TO VALVE AS REQUIRED BY THE CITY 3 INCH AND ABOVE ASSEMBLY DETECTOR METER BALL VALVE (2 REQUIRED) CONCRETE SLAB DOUBLE CHECK VALVE ASSEMBLY (MINIMUM) 1 1'0" MIN I ABOVE GROUND DEVICE WITH �- 2'0" MIN DETECTOR BYPASS DOUBLE CHECK OR REDUCED PRESSURE ZONE DETECTOR ASSEMBLY CITY OF SANFORD 1999 FIG. 500B 0 Z Lw LU Z Z LUV 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Certificate of Authorization No.: 9230 tlydd��`!, G. o. �.. • 1I- �• .� >A� AL�� ./!Il Selby G. Weeks 56991 ^o F --i r-1 C) W O W W W O 0 f� U ) W revision description date 1L Owner Revision 03.28.18 0 City Comments 06.05.18 Owner Revision 09.14.18 0 0 drawn by: RVZ checked by: SGW date: 03/o9/18 plot scale: AS SHOWN project number: 17RINEoo1 file name: X-36,„ fit, Wk - RmAan dwg 6" INTERIOR FIRE SPRINKLER RISER SPIG('T 6" DR -14 FROM U.G. SUPPLY (REFER TO U.G. 6" FIREKEYRPLANTIOHISPPAGE (BY FOR CONTINUATION) UP 4" TO THE 1ST FLOOR COP VALVE REFER TO "FLOOR COP VALVE ASSEMBLY SECTION VIEW D ON SHEETS FP -2 & I BUILDING "A" - FIRST FLOOR FIRE SPRINKLER PIPING PLAN SCALE NOTE: THE GENERAL NOTES, DETAILS, DESIGN CRITERIA, AND HYDRAULIC CALCULATION PLACARDS WILL NOT FIT ON THIS SHEET AND AS SUCH ARE INCLUDED ON SHEETS FP -2 OF 3 & FP -3 OF 3; THE NOTES, DETAILS, DESIGN CRITERIA, ETC... COVER ALL THREE FLOORS OF THIS BUILDING S.I.N. #R3622 406 3/4" (8.OK) 155' QR RELIABLE F1 FRLO UPR. BRASS NO ESC. REFER TO NOTES FOR MAX SPACING PER SPRINKLER S.I.N. #RA1435 1/2" (5.6K) 286 QR RELIABLE F1 FR HSW BRASS NO ESC. 100 SQ. FT. MAX SPACING PER SPRINKLER S.I.N. WR5734 UWHT 100 SQ. FT. MAX SPACING PER SPRINKLER JJ 0ONSULTING GR®UP, INC. CA LICENSE #31 838 JORGE J. SALGADO, P.E. #53600 2001 TLZEWELL CIRCLE #1509 ORLANDO, FL 32837 1/8" = 1'-0" . ...... S I N G L E Suu iiCE S 0 L %ur' T 10% •SPRINKLER - u Cpm � f F-- 0(if wa>--u._jWgdwtY . ZZCD CO Ill _w0`jm0 Fa -2 w `Lu--iWw wm QCU N �C3Q�OOQ� u'ZZox2g z rra�j. "_` fL' Q�aoz=JO_�LL'Lt.m CZ LL zdwWQVu-aLLWF-ZOO - Z Lpa Z p d Z Z a Y L Z O> L'- _0 0 t��iltfftftr ,00 cr 'S� a0d o<ZLUxd~UO �'�` �f#,� J Z k- LL w ~ w p z u� /.n o Iti' : < .« ¢. •t("""� •` 00 o 00 O 12" DR -14 1000'-0" f (BY OTHERS) TO DOMESTIC WATER (BY OTHERS) NEW 6" DOUBLE CHECK DETECTOR ASSEMBLY (DCDA) _ABACKFLOW PREVENTER W/ 4" z 2j�" x M" FDC THE FIRE SPRINKLER SYSTEM POINT OF SERVICE �� �REVENTER P.O.S.) IS AT THE SUPPLY SIDE OF THE BACKFLOW \\ (I.E.-THE FIRST OS&Y VALVE) // 6" DP. -14 199'-0" f (BY OTHERS) NEW FIRE HYDRANT (BY OTHERS) SPG y 6" INTERIOR SPIGOT TO FEED THE RISER -RINEHART SELF STORAGE - UNDERGROUND FIRE PROTECTION PLAN/KEY PLAN SCALE NOTE: THE U.G. FIRE PROTECTION SHOWN HERE IS BY OTHERS IS NOT TO SCALE, AND IS FOR HYDRAULIC CALCULATION REFERENCE PURPOSES ONLY N. T. S. HANGER #1 BAR JOIST TOP BEAM CLAMP & ALL THREAD ROD SIZES FOR 1" THRU 4" PIPE 3/8" TO BE USED FOR 6" & 8" PIPE 1/2" TO BE USED T.B.C. STE ZINC ATR SCALE HANGER #2A SAM MY SIDEWINDER NC ATR HANGER #4 CONC. STRUCTURE HANGER RING HANGER DETAILS N.T.S. >CREW CRETE Z HANGER RING CONCRETE WALL OR FLOOR 1/4' CROWN OF FIRESTOP SEALANT STEEL PIPE UP TO 12' ANNULUS+ POINT CONTACT TO V MAXIMUM V PACKED �\11-4/2' DEPTH OF MINERAL WOOL FIRESTOP SEALANT UL SYSTEM NUMBER CAJ-1353 F RATING, 3 HR T RATING; O HR SEALANT; STI SPECSEAL LCI -300 STEEL PIPE CONCRETE WALL PENETRATION N.T.S. 5/8' TYPE 'X' GYP. BRD, FOR 1 HR RATING & 2 x 5/8' TYPE 'X' GYP, BIRD, FOR 2 HR RATING STEEL PIPE UP TO 8' ANNULUS; POINT CONTACT TO 2' MAXIMUM 1/4' CROWN OF FIRESTOP SEALANT AT CONTACT POINTS II ;r, II 5/8' DEPTH OF FIRESTOP UL SYSTEM NUMBER W -L-1222 F RATING; 1 AND 2 HR T RATING; ' I & 1 HR SEALANT; STI SPECSEAL LCI -3000 STEEL PIPE DRY WALL PENETRATION N.T.S. 1X" DRAIN _\ 14" RISER 1%" DRAIN TO BE CUT IN FIEL[ 1X" DRAIN TO BE CUT IN FIEL[ SYSTEM MANIFOLD W/ GAUGE ASSEMBLY, T GLASS, & FLOW SWITCH .{ FLOOR CONTROL VALVE ASSEMBLY SECTION VIEW DETAIL S.I.N. #R3622 461 3/4,(8.OK) 155' QR RELIABLE F1 FRLO UPR. BRASS NO ESC. —0- 130 SQ. FT. MAX SPACING PER SPRINKLER BUILDING "A" - SECOND FLOOR FIRE SPRINKLER PIPING PLAN SCALE dd C0NSLJLTING GPOUP, INC. CA LICENSE #31 338 JORGE J. r.J-AL.GADO, P.E. #530500 2001 TIZEWELL. CIPOLE #1 509 ORLANDO, FL 32837 1/8" = 1'-0" /rau :,iJ,y t7y y�� 9" v.`r�` v..,...✓ --�// Sa6 �� '�..+..i ,�� �^ � ��w� \..rss+'. -i:�i f I U L T I SIN GLE Su' K S u U �« FIRE ALARM -SPRINKLER -SECURITY RISER (TYP. NES) GENERAL NOTES: 1. ALL WORK, DESIGN, MATERIALS, AND INSTALLATION TO BE IN ACCORDANCE W/ NFPA #13, 2013 EDITION, THE MANUFACTURERS LISTING, & THE AUTHORITY HAVING JURISDICTION. 2. THE DESIGN CRITERIA FOR THE OVERHEAD FIRE SPRINKLER SYSTEM(S) IS AS FOLLOWS: A.) ORDINARY HAZARD GROUP 2 AREAS: WET PIPE SYSTEM DESIGNED IN ACCORDANCE W/ NFPA 13, 2013 EDITION TO PROVIDE A .20 DENSITY FOR ALL, INCLUDING THE MOST REMOTE 1500 SQ. FT. HYDRAULIC DESIGN AREA. (THE HYDRAULIC DESIGN AREAS HAVE BEEN REDUCED AS ALLOWED BY NFPA 13, 2013 EDITION, SECTION 11.2.3.2.3.1; IN ADDITION, IN ACCORDANCE WITH NFPA #13, 2013 EDITION, TABLE 23.4.4.6.2. & A.23.4.4.6.2, THE SPRINKLERS IN THE SMALL STORAGE UNIT ROOMS HAVE BEEN OMITTED FROM BEING INCLUDED IN THE HYDRAULIC DESIGN AREA.) B.) LIGHT HAZARD AREAS: WET PIPE SYSTEM DESIGNED IN ACCORDANCE W/ NFPA 13, 2013 EDITION TO PROVIDE A .10 DENSITY FOR ALL, INCLUDING THE MOST REMOTE 1500 SQ. FT. HYDRAULIC DESIGN AREA. 3. THE OCCUPANCY OF THIS BUILDING IS THAT OF A SELF—STORAGE TYPE OF FACILITY AND IS CLASSIFIED AS AN ORDINARY HAZARD GROUP 2 OCCUPANCIES SINCE THE TYPE OF STORAGE IS CONSIDERED TO BE "INCIDENTAL STORAGE" UP TO A MAX. STORAGE HEIGHT OF 12'-0" IN ACCORDANCE WITH NFPA 13, 2013 EDITION FOR ANY ORDINARY HAZARD GROUP TWO OCCUPANCY. 4. THE MAX. SPACING OF THE SPRINKLERS IN THE ORDINARY HAZARD OCCUPANCIES IS NOT TO EXCEED 130 SQ. FT. PER SPRINKLER IN ACCORDANCE W/ NFPA 13, 2013 ED. FOR ANY ORDINARY HAZARD OCCUPANCY WHILE THE MAX SPACING OF THE SPRINKLERS IN THE LIGHT HAZARD OCCUPANCIES IS NOT TO EXCEED 225 SQ. FT. PER SPRINKLER IN ACCORDANCE WITH NFPA #13, 2013 EDITION. 5. THE TOP OF THE WALLS IN THE INDIVIDUAL SELF—STORAGE UNITS ARE LESS THAN 18" BELOW THE DECK; THEREFORE, THE WALLS ARE CONSIDERED TO BE OBSTRUCTIONS TO THE SPRAY PATTERN OF THE SPRINKLER HEADS. AS SUCH, SPRINKLER PROTECTION IS INCLUDED IN EVERY INDIVIDUAL SELF STORAGE UNIT. SINCE EACH OF THE WALLS ARE CONSIDERED TO BE OBSTRUCTIONS, ANY HEAD THAT IS CLOSER THAN 6'-0" APART WILL NOT COLD SODER. 6. THE PIPE & FITTINGS TO BE USED ARE AS FOLLOWS: A.) GROOVED PIPING 1-1/2"-4": SCH. 10 BLACK W/ GROOVED COUPLINGS/FITTINGS. B.) THREADED PIPING 1"-2": SCH. 4-0 BLACK W/ THREADED FITTINGS. 7. ALL FIREWALL PENETRATIONS ARE TO BE SEALED IN ACCORDANCE WITH THEIR RATING. 8. ALL PIPE DIMENSIONS ARE CENTER TO CENTER. 9. ALL PIPE HANGERS INSTALLED PER NFPA 13, 2013 ED. & THE MANUFACTURERS LISTING. NO. DATE REVISION DESCRIPTION - ' 4" TO {BE CUT IN FIELD _FIN. FLR.. �--4" TO OVE 4" COMMERCIAL RISER RHEA 8-19-18 G.C./A.H.J. SUBMITTAL IVAN TEST N' DRAIN & SIGIa LL »r ► " / (WIRING BY OTHE S) w�s Uuj B.F. VA. T. (WIRING BY OTHERS) ( OT . jF _ o it N 1 I #rtirttttir;►r N 4" RISER 00 0 FIN. FLR 4" TO BE CUT IN FIELD ................ .......... .... ........ ................... ...... ",......... _.... _..................... -....... i.............. SYSTEM MANIFOLD W/ GAUGE ASSEMBLY, T GLASS, & FLOW SWITCH .{ FLOOR CONTROL VALVE ASSEMBLY SECTION VIEW DETAIL S.I.N. #R3622 461 3/4,(8.OK) 155' QR RELIABLE F1 FRLO UPR. BRASS NO ESC. —0- 130 SQ. FT. MAX SPACING PER SPRINKLER BUILDING "A" - SECOND FLOOR FIRE SPRINKLER PIPING PLAN SCALE dd C0NSLJLTING GPOUP, INC. CA LICENSE #31 338 JORGE J. r.J-AL.GADO, P.E. #530500 2001 TIZEWELL. CIPOLE #1 509 ORLANDO, FL 32837 1/8" = 1'-0" /rau :,iJ,y t7y y�� 9" v.`r�` v..,...✓ --�// Sa6 �� '�..+..i ,�� �^ � ��w� \..rss+'. -i:�i f I U L T I SIN GLE Su' K S u U �« FIRE ALARM -SPRINKLER -SECURITY RISER (TYP. NES) GENERAL NOTES: 1. ALL WORK, DESIGN, MATERIALS, AND INSTALLATION TO BE IN ACCORDANCE W/ NFPA #13, 2013 EDITION, THE MANUFACTURERS LISTING, & THE AUTHORITY HAVING JURISDICTION. 2. THE DESIGN CRITERIA FOR THE OVERHEAD FIRE SPRINKLER SYSTEM(S) IS AS FOLLOWS: A.) ORDINARY HAZARD GROUP 2 AREAS: WET PIPE SYSTEM DESIGNED IN ACCORDANCE W/ NFPA 13, 2013 EDITION TO PROVIDE A .20 DENSITY FOR ALL, INCLUDING THE MOST REMOTE 1500 SQ. FT. HYDRAULIC DESIGN AREA. (THE HYDRAULIC DESIGN AREAS HAVE BEEN REDUCED AS ALLOWED BY NFPA 13, 2013 EDITION, SECTION 11.2.3.2.3.1; IN ADDITION, IN ACCORDANCE WITH NFPA #13, 2013 EDITION, TABLE 23.4.4.6.2. & A.23.4.4.6.2, THE SPRINKLERS IN THE SMALL STORAGE UNIT ROOMS HAVE BEEN OMITTED FROM BEING INCLUDED IN THE HYDRAULIC DESIGN AREA.) B.) LIGHT HAZARD AREAS: WET PIPE SYSTEM DESIGNED IN ACCORDANCE W/ NFPA 13, 2013 EDITION TO PROVIDE A .10 DENSITY FOR ALL, INCLUDING THE MOST REMOTE 1500 SQ. FT. HYDRAULIC DESIGN AREA. 3. THE OCCUPANCY OF THIS BUILDING IS THAT OF A SELF—STORAGE TYPE OF FACILITY AND IS CLASSIFIED AS AN ORDINARY HAZARD GROUP 2 OCCUPANCIES SINCE THE TYPE OF STORAGE IS CONSIDERED TO BE "INCIDENTAL STORAGE" UP TO A MAX. STORAGE HEIGHT OF 12'-0" IN ACCORDANCE WITH NFPA 13, 2013 EDITION FOR ANY ORDINARY HAZARD GROUP TWO OCCUPANCY. 4. THE MAX. SPACING OF THE SPRINKLERS IN THE ORDINARY HAZARD OCCUPANCIES IS NOT TO EXCEED 130 SQ. FT. PER SPRINKLER IN ACCORDANCE W/ NFPA 13, 2013 ED. FOR ANY ORDINARY HAZARD OCCUPANCY WHILE THE MAX SPACING OF THE SPRINKLERS IN THE LIGHT HAZARD OCCUPANCIES IS NOT TO EXCEED 225 SQ. FT. PER SPRINKLER IN ACCORDANCE WITH NFPA #13, 2013 EDITION. 5. THE TOP OF THE WALLS IN THE INDIVIDUAL SELF—STORAGE UNITS ARE LESS THAN 18" BELOW THE DECK; THEREFORE, THE WALLS ARE CONSIDERED TO BE OBSTRUCTIONS TO THE SPRAY PATTERN OF THE SPRINKLER HEADS. AS SUCH, SPRINKLER PROTECTION IS INCLUDED IN EVERY INDIVIDUAL SELF STORAGE UNIT. SINCE EACH OF THE WALLS ARE CONSIDERED TO BE OBSTRUCTIONS, ANY HEAD THAT IS CLOSER THAN 6'-0" APART WILL NOT COLD SODER. 6. THE PIPE & FITTINGS TO BE USED ARE AS FOLLOWS: A.) GROOVED PIPING 1-1/2"-4": SCH. 10 BLACK W/ GROOVED COUPLINGS/FITTINGS. B.) THREADED PIPING 1"-2": SCH. 4-0 BLACK W/ THREADED FITTINGS. 7. ALL FIREWALL PENETRATIONS ARE TO BE SEALED IN ACCORDANCE WITH THEIR RATING. 8. ALL PIPE DIMENSIONS ARE CENTER TO CENTER. 9. ALL PIPE HANGERS INSTALLED PER NFPA 13, 2013 ED. & THE MANUFACTURERS LISTING. NO. DATE REVISION DESCRIPTION BY 0 8-19-18 G.C./A.H.J. SUBMITTAL IVAN LL »r ► " / 0 0 w�s Uuj . L I U w R NEHART SELF STORAGE 0 2 RINEHART RD. SANFORD, FL 32771 Q Building "A" — Second Floor Fire Protection Plan REVISION SYSTEM NUMBER JOB NUMBER DRAWING NUMBER 0 SYSTEM # 1 FP -2 OF 3 IN�r"i»s�+4f, LL »r ► " / 0 0 w�s Uuj #rtirttttir;►r N 00 0 U w R NEHART SELF STORAGE 0 2 RINEHART RD. SANFORD, FL 32771 Q Building "A" — Second Floor Fire Protection Plan REVISION SYSTEM NUMBER JOB NUMBER DRAWING NUMBER 0 SYSTEM # 1 FP -2 OF 3 HANGER #1 BAR JOIST TOP BEAM CLAMP & ALL THREAD ROD SIZES FOR 1" THRU 4" PIPE 3/8" TO BE USED FOR 6" & 8" PIPE 1/2" TO BE USED T.B.C. STE ZINC ATR HANGER SCALE HANGER #2A SAMMY SIDEWINDER NC ATR HANGER #4 CONC. STRUCTURE HANGER RING HANGER DETAILS N.T.S. SCREW JCRETE HANGER RING CONCRETE WALL OR FLOOR 1/4' CROWN OF FIRESTOP SEALANT STEEL PIPE UP TO 12' ANNULUS; POINT CONTACT TO 1' MAXIMUM 1' PACKED �1/2' DEPTH OF MINERAL WOOL FIRESTOP SEALANT UL SYSTEM NUMBER CAJ-1353 F RATING; 3 HR T RATING; O HR SEALANT, STI SPECSEAL LCI -300 STEEL PIPE CONCRETE WALL PENETRATION N. T. S. 5/8' TYPE 'X' GYP, BRD, FOR 1 HR RATING & 2 x 5/8' TYPE 'X' GYP. BIRD, FOR 2 HR RATING 1/4' CROWN OF STEEL PIPE UP TO 8' FIRESTOP SEALANT AT CONTACT POINTS ANNULUS; POINT CONTACT TO 2' MAXIMUM 5/8' DEPTH OF FIRESTOP UL SYSTEM NUMBER W -L-1222 F RATING, 1 AND 2 HR T RATING1 t � & 1 HR SEALANT; STI SPECSEAL LCI -3000 STEEL PIPE DRY WALL PENETRATION N.T.S. 1X4" DRAIN /_4" RISER 4" TO 'BE CUT IN FIELD 1X4" DRAIN TO BE CUT IN FIELD I —4" TO OVEPHEAD SYSTEM 4" COMMERCIAL RISER MANIFOLD W/ GAUGE ASSEMBLY, I TEST N' DRAIN &I SIGHT GLASS, & FLOW SWITCH I(WIRING BY OTHERS) B.F. VA. W/ T.S.: (WIRING BY OTHERS) i - _ o �ti N I i 1X4" DRAIN TO BE CUT IN FIELD 4" RISER 4" TO BE CUT IN FIELD FLOOR CONTROL VALVE ASSEMBLY SECTION VIEW DETAIL 11M A" TA n Ir -7nn ri nnn S.I.N. #R3622 464 64 3/4" (8.OK) 155' QR RELIABLE F1 FRLO' UPR. BRASS NO ESC. —0- 130 SQ. FT, MAX SPACING PER SPRINKLER BUILDING "A" - THIRD FLOOR FIRE SPRINKLER PIPING PLAN SCALE — 1/8" = 1'-0" 4JJ CONSULTING GROUP, INC. CA LICENSE #31 832 JORGE J. 5ALGAD09 P.E. #53600 2001 TIZEWELL CIRCLE #1509 ORLANDO, FL 32837 M y /F 1 .3ell% SINGLE SuuKCE S'L"Tlut : A U N FIRE ALARM -SPRINKLER -SECURITY__ GENERAL NOTES: 1. ALL WORK, DESIGN, MATERIALS, AND INSTALLATION TO BE IN ACCORDANCE W/ NFPA #13, 2013 EDITION, THE MANUFACTURERS LISTING, & THE AUTHORITY HAVING JURISDICTION. 2. THE DESIGN CRITERIA FOR THE OVERHEAD FIRE SPRINKLER SYSTEM(S) IS AS FOLLOWS: A.) ORDINARY HAZARD GROUP 2 AREAS: WET PIPE SYSTEM DESIGNED IN ACCORDANCE W/ NFPA 13, 2013 EDITION TO PROVIDE A .20 DENSITY FOR ALL, INCLUDING THE MOST REMOTE 1500 SQ. FT. HYDRAULIC DESIGN AREA. (THE HYDRAULIC DESIGN AREAS HAVE BEEN REDUCED AS ALLOWED BY NFPA 13, 2013 EDITION, SECTION 11.2.3.2.3.1; IN ADDITION, IN ACCORDANCE WITH NFPA #13, 2013 EDITION, TABLE 23.4.4.6.2. & A.23.4.4.6.2, THE SPRINKLERS IN THE SMALL STORAGE UNIT ROOMS HAVE BEEN OMITTED FROM BEING INCLUDED IN THE HYDRAULIC DESIGN AREA.) B.) LIGHT HAZARD AREAS: WET PIPE SYSTEM DESIGNED IN ACCORDANCE W/ NFPA 13, 2013 EDITION TO PROVIDE A .10 DENSITY FOR ALL, INCLUDING THE MOST REMOTE 1500 SQ. FT. HYDRAULIC DESIGN AREA. 3. THE OCCUPANCY OF THIS BUILDING IS THAT OF A SELF—STORAGE TYPE OF FACILITY AND IS CLASSIFIED AS AN ORDINARY HAZARD GROUP 2 OCCUPANCIES SINCE THE TYPE OF STORAGE IS CONSIDERED TO BE "INCIDENTAL STORAGE" UP TO A MAX. STORAGE HEIGHT OF 12'-0" IN ACCORDANCE WITH NFPA 13, 2013 EDITION FOR ANY ORDINARY HAZARD GROUP TWO OCCUPANCY. 4. THE MAX. SPACING OF THE SPRINKLERS IN THE ORDINARY HAZARD OCCUPANCIES IS NOT TO EXCEED 130 SQ. FT. PER SPRINKLER IN ACCORDANCE W/ NFPA 13, 2013 ED. FOR ANY ORDINARY HAZARD OCCUPANCY WHILE THE MAX SPACING OF THE SPRINKLERS IN THE LIGHT HAZARD OCCUPANCIES IS NOT TO EXCEED 225 SQ. FT. PER SPRINKLER IN ACCORDANCE WITH NFPA #13, 2013 EDITION. 5. THE TOP OF THE WALLS IN THE INDIVIDUAL SELF—STORAGE UNITS ARE LESS THAN 18" BELOW THE DECK; THEREFORE, THE WALLS ARE CONSIDERED TO BE OBSTRUCTIONS TO THE SPRAY PATTERN OF THE SPRINKLER HEADS. AS SUCH, SPRINKLER PROTECTION IS INCLUDED IN EVERY INDIVIDUAL SELF STORAGE UNIT. SINCE EACH OF THE WALLS ARE CONSIDERED TO BE OBSTRUCTIONS, ANY HEAD THAT IS CLOSER THAN 6'-0" APART WILL NOT COLD SOLDER. 6. THE PIPE & FITTINGS TO BE USED ARE AS FOLLOWS: A.) GROOVED PIPING 1-1/2"-4": SCH. 10 BLACK W/ GROOVED COUPLINGS/FITTINGS. B.) THREADED PIPING 1"-2": SCH. 40 BLACK W/ THREADED FITTINGS. 7. ALL FIREWALL PENETRATIONS ARE TO BE SEALED IN ACCORDANCE WITH THEIR RATING. 8. ALL PIPE DIMENSIONS ARE CENTER TO CENTER. 9. ALL PIPE HANGERS INSTALLED PER NFPA 13, 2013 ED. & THE MANUFACTURERS LISTING. IGN AREA #1 1004 SQ. FT. 10 HEADS Hydraulically Designed FLOW TEST DATA STATIC: 50 PSI RESIDUAL: 48 PSI FLOW: 1110 GPM DATE: 1-7-18 Design Area Size 1004 TIME: 1:10 PM LOCATION: SITE HYDRANTS ON RINEHART ROAD BY: FARRELLL FIRE PROTECTION LLC Hydraulically Designed System Location DA #1 No. of Sprinklers 10 Density .20 Design Area Size 1004 SQ. FT. System Demand At Base of Riser GPM Discharge 223.17 Residual PSI 19.827 NOTE: THE DESIGN AREA HAS BEEN REDUCED BY 33.07% FOR A MAX. DECK/CEILING HEIGHT OF 14'-7�" IN ACCORDANCE W/ NFPA 13, 2013 EDITION, SECTION 11.2.3.2.3.1 IN ACCORDANCE WITH NFPA #13, 2013 EDITION, TABLE 23.4.4.6.2. & A.23.4..6.2, THE SPRINKLERS IN THE SMALL STORAGE UNIT ROOMS HAVE BEEN OMITTED FROM BEING INCLUDED IN THE HYDRAULIC DESIGN AREA. NO. DATE REVISION DESCRIPTION BY 0 8-19-18 G.C./A.H.J. SUBMITTAL IVAN ` (tit `%f.•41 ."%• y y�' pl��� ( y 7 w • c < .. U w RINEHART SELF STORAGE CL RINEHART RD. SANFORD, FL 32771 Q Building "A" — Third Floor Fire Protection Plan REVISION SYSTEM NUMBER JOB NUMBER DRAWING NUMBER 0 SYSTEM # 1 FP -3 OF 3 CPO ` (tit `%f.•41 ."%• y y�' pl��� ( y 7 w • c < .. 0 U w RINEHART SELF STORAGE CL RINEHART RD. SANFORD, FL 32771 Q Building "A" — Third Floor Fire Protection Plan REVISION SYSTEM NUMBER JOB NUMBER DRAWING NUMBER 0 SYSTEM # 1 FP -3 OF 3 drainage manhole Top elev. = 43.60' S Invert = 37.10' (18" x 30" RCP) N Invert - 37.00' (18" x 30" RCP) e" ou i Test hole Test hole 02 0 47.2' 22 hole 45 hole 44 hole #3 drainage inlet Top elev. - 44.02' S invert - 39.07' (18" x 30" RCP) N invert - 39.00' I (18" x 30" RCP) ;45.19 D-9 Boundary and .Topographic Survey of a portion of Lot 1, PINE LAKE GROVES, Plat Book 9, Page 27 Section 33, Township 19 South, Range 30 East Seminole County, Florida PERMIT # �: 7J 5' / f� r C ` d \ (� GRAPHIC SCALE 50 0 25 50 100 200 N Point of Commencement Northwest comer of the NorthwestIN FEET �- _RF E '\ r 1/4 of Section 33, Township 19 () Y Y South, Range 30 East J Recovered nail and disk in � �( j� � \�( 1 inch - 50 it. �c(1 avement stamped # 065370 ' i � P P OF FICE Lot 1 X� BEST BUY ON RINEHART ROAD Lo+ 1, WAL-MART Plot Book 66, Pages 49-50 "Best Buy" building SUPERSTORE ON RINEHART ROAD S floor elev. - 48.1' Plat Book 65, Pages 31-32 i g J / 45.48 .31 �•� X4518 4517 45U46.43"74,%44 concre sidewalk edge of water ��j^j7 i �� X39.87 X41.87 44. .37 45. x44.48 eIOV. 33.5' / X)36.88 S� x43.94 drainage inlet Ss3 45.2 4S Li I I40 x3864' X36 37`35 �- _ rm D-7 // { ` I Top elev. 38.40' 75 31 4500 45.14 4283 1 W \ \x38.30 38.1(Y-' 8-____s. ; -� , '3�-_~ "`-^- - - - x / \ W Invert = 31.20' (42" RCP) I ( 44.87 68 concrete { " edge of water `(4\ 40 \-36- - { N invert = 31.00' (42" RCP) I X3. _ I \ 3 4 .92 29 44.88 44 9 �\ drivewaytt 1t edge of water \ 9� 3 x1 ` --x3e. 3Z - I -`P\ -X 7 �� 37-----� _ X37.3 asphalt X43.2 --..+` .- X37.81 r - _ --.38` ` - ✓ { X39.08 X4&05 asphalt driveway and parking lot x45.37 x4835 45.05X X4472 �8 x4415 x44.51 D'S \\ \,' edge of water \ 41 +- �!� -'X356 1 / / dge of pavement 1.5' curb 42.76 concrete retaining wall 4 �40-_� ?•� _ p -g x3&20� 48.18 48.85 45.43 44 9D 44.64 45.05 43.1 elev. = 38.2' 43 42 ( 4 4�- - - X 8- - 37-- . & / OOAK14 OAK15 AKt OAK11 OMAGB A 14 AK OAK70 11 MPA A 6. /llit%i811nk fenn.7T -- 1 CYP 6 OAK18 O X47.23 10 \ �' a 46.94 49.B5xMA 6 D-3 N 89"52'39" E AK13 D-4 YRg CYi'8 L ,�ClP6 � 1318.88' ' \ ¢3 OAK13 Ct OA OAK15 \ 8� 0 0006 0CA�38.83 5' " , 72 \ /ti OAKS OAKS OAK 76 - - Northers extension of the East \ / x4337 x;3,7- -43- `� / 'k 3.04 o d`DitIG8 S 00'25 04 W 30.00 D-2 y y o \ North line of Section 33 x4545 . �q5 -- x44 72 / '�` �' �• o ~�. oAKt2 0 rest hole 45 a \ --.. Wilson Avenue (30 b0 R/W per P.B. 9, Pg. 27) O AKTIMNB(WW� \ X41.53,\ o `e OAK15 ` - - - f � Y X4p ;hole �7 mak'►' r�j \ `I �¢e� • ' " % ' °� \ \ \ \M �'� `-~~ x39.30 1 // line of Lot 1, Pine Lake Groves, \ \ N 89 52 9 E 1302.90 /Plat Book 9, Page 27 \ PALM \ y e 3 / OOAK3s OWOAK10 / \ \ \ `' - , _. �' \ 3$.e2 Point of Beginning I I 6' high chain link fence / North line of Lot 1, Pine Lake I OOAX28 eP X43.43 00AK6 / \ -- x40.52 \ / //�/� Northeast line of Lot 1 Pine Lake ends 2.5' south of corner \ Groves, Plat Book 9, Pae 27 / \ \ ®OAK13 `'�fl(TWIN12 I -� /moi/ Groves, Plat Book 9, Page 27 4$.60 I I X48.31 \ �a1 g , I OOAKB / e0AK8 / Gl�\ \ \ ` ` - OAK11 OAK�M�10 / i / 4a.2o `� I X48 44 1 DOAK I X43 84 0OAK24 X43.ei / X43.73 44 of N. I T I r( � O 5' high metal rail fence 70.0 x48.84 ' 0OA46 ` _, \ / � \ 10,<K12 / { 48.30 46 del D-1 Inlet D-6 inlet Top slay. = 47.59' 47.0 04 1 I NW invert - 41.09 (36" RCP) O E I 46.71 II C N cCL d i L � � L L � OC U bl I .0 CL d, J I hole 45 hole 44 hole #3 drainage inlet Top elev. - 44.02' S invert - 39.07' (18" x 30" RCP) N invert - 39.00' I (18" x 30" RCP) ;45.19 D-9 Boundary and .Topographic Survey of a portion of Lot 1, PINE LAKE GROVES, Plat Book 9, Page 27 Section 33, Township 19 South, Range 30 East Seminole County, Florida PERMIT # �: 7J 5' / f� r C ` d \ (� GRAPHIC SCALE 50 0 25 50 100 200 N Point of Commencement Northwest comer of the NorthwestIN FEET �- _RF E '\ r 1/4 of Section 33, Township 19 () Y Y South, Range 30 East J Recovered nail and disk in � �( j� � \�( 1 inch - 50 it. �c(1 avement stamped # 065370 ' i � P P OF FICE Lot 1 X� BEST BUY ON RINEHART ROAD Lo+ 1, WAL-MART Plot Book 66, Pages 49-50 "Best Buy" building SUPERSTORE ON RINEHART ROAD S floor elev. - 48.1' Plat Book 65, Pages 31-32 i g J / 45.48 .31 �•� X4518 4517 45U46.43"74,%44 concre sidewalk edge of water ��j^j7 i �� X39.87 X41.87 44. .37 45. x44.48 eIOV. 33.5' / X)36.88 S� x43.94 drainage inlet Ss3 45.2 4S Li I I40 x3864' X36 37`35 �- _ rm D-7 // { ` I Top elev. 38.40' 75 31 4500 45.14 4283 1 W \ \x38.30 38.1(Y-' 8-____s. ; -� , '3�-_~ "`-^- - - - x / \ W Invert = 31.20' (42" RCP) I ( 44.87 68 concrete { " edge of water `(4\ 40 \-36- - { N invert = 31.00' (42" RCP) I X3. _ I \ 3 4 .92 29 44.88 44 9 �\ drivewaytt 1t edge of water \ 9� 3 x1 ` --x3e. 3Z - I -`P\ -X 7 �� 37-----� _ X37.3 asphalt X43.2 --..+` .- X37.81 r - _ --.38` ` - ✓ { X39.08 X4&05 asphalt driveway and parking lot x45.37 x4835 45.05X X4472 �8 x4415 x44.51 D'S \\ \,' edge of water \ 41 +- �!� -'X356 1 / / dge of pavement 1.5' curb 42.76 concrete retaining wall 4 �40-_� ?•� _ p -g x3&20� 48.18 48.85 45.43 44 9D 44.64 45.05 43.1 elev. = 38.2' 43 42 ( 4 4�- - - X 8- - 37-- . & / OOAK14 OAK15 AKt OAK11 OMAGB A 14 AK OAK70 11 MPA A 6. /llit%i811nk fenn.7T -- 1 CYP 6 OAK18 O X47.23 10 \ �' a 46.94 49.B5xMA 6 D-3 N 89"52'39" E AK13 D-4 YRg CYi'8 L ,�ClP6 � 1318.88' ' \ ¢3 OAK13 Ct OA OAK15 \ 8� 0 0006 0CA�38.83 5' " , 72 \ /ti OAKS OAKS OAK 76 - - Northers extension of the East \ / x4337 x;3,7- -43- `� / 'k 3.04 o d`DitIG8 S 00'25 04 W 30.00 D-2 y y o \ North line of Section 33 x4545 . �q5 -- x44 72 / '�` �' �• o ~�. oAKt2 0 rest hole 45 a \ --.. Wilson Avenue (30 b0 R/W per P.B. 9, Pg. 27) O AKTIMNB(WW� \ X41.53,\ o `e OAK15 ` - - - f � Y X4p ;hole �7 mak'►' r�j \ `I �¢e� • ' " % ' °� \ \ \ \M �'� `-~~ x39.30 1 // line of Lot 1, Pine Lake Groves, \ \ N 89 52 9 E 1302.90 /Plat Book 9, Page 27 \ PALM \ y e 3 / OOAK3s OWOAK10 / \ \ \ `' - , _. �' \ 3$.e2 Point of Beginning I I 6' high chain link fence / North line of Lot 1, Pine Lake I OOAX28 eP X43.43 00AK6 / \ -- x40.52 \ / //�/� Northeast line of Lot 1 Pine Lake ends 2.5' south of corner \ Groves, Plat Book 9, Pae 27 / \ \ ®OAK13 `'�fl(TWIN12 I -� /moi/ Groves, Plat Book 9, Page 27 4$.60 I I X48.31 \ �a1 g , I OOAKB / e0AK8 / Gl�\ \ \ ` ` - OAK11 OAK�M�10 / i / 4a.2o `� I X48 44 1 DOAK I X43 84 0OAK24 X43.ei / X43.73 44 of N. I T I r( � O 5' high metal rail fence 70.0 x48.84 ' 0OA46 ` _, \ / � \ 10,<K12 / { 48.30 46 del D-1 Inlet D-6 inlet Top slay. = 47.59' 47.0 04 1 I NW invert - 41.09 (36" RCP) O E I D-2 manhole II C N cCL d i L � � L L � OC U bl I .0 CL a L 47.75 .0 D-3 inlet Top elev. = 45.48' Q!� cI 6E I �' 49.44 I I V a 49.01 '6614 47.01 2 CX M 0 0^- 1 c� g,49.57 a?! (inlet still has felt paper D-5 inlet covering bottom of grate) Top elev. = 42.53' d a 49.61 d 3 v { e' m 49.71 r e e .111 47.54 49.53 X47.16 (Invert information taken from asbullt survey provided by the client) 50.02 o I 50.09 ® 47.51 48.25 drain go manhole Top elev. = 47.89' I N invert = 39.79' (18" RCP) SW Invert = 43.27' (18" RCP) West line of Section 33 II 04 I X48.92 , \ /� x44.08 y, -- _ _ / CJ ` %N4196 OAK21 OAK300 III m 'R - 2616.47' , , %4472 \ O?AK6 OOAKB \ ?\ \ I III D = 4'06'35" / \ 1 ` / x4418 x4418 \ \ \ \ \ \ I \ \ X40.72retaining wall , 47.9 building L = 187.67' , ` ` OAKTWIN6 00gkTWIN13 I II pVj I e r " ` OAKTWINB CK12K8 OOAKTWINiB \ OOAK36 \ \ drainage inlet-, cn CB=N024316 E / \ / \ aC = 187.63f / / ` x46.37 *OAKTw1N6 \\ / Portion of Lot 1 \'�- -- - - - - -44-, \ \ \ \ ✓ / 42.16X' �T 4�aX4t.9� \\ t p eiev. - 33.73' ' \ \�� �Ic48.08 X48.84 / 1 x46.41 x48.87 0 LM14 GOAKTMNi4 oAKT""N7 PINE LAKE GROVES \ \ \ \ i8,re RCP 39 B S XP._411 �►5.7t 4J OOAKB oOAKS / , / `X41. OAK7 p OAKSX42. 28 42: 3` P. 41.$3 I \ N \ \ i 1 " I OOAKII2 / X4490 OAKS X44,80 ' �� P.B. 9Ca Page 27 X44.58 X4444 \ \\ \ \4284\ \ \ X40.06 61 \ high metal roll fence W / 47.24 X `� \ \ \ �41J � I OOAK13 -r'x45.12 '�•-� OOAK12 Recovered 5/8" iron / - 5a� \ \\ \ \ ` `/' �\ I V tV \, X41.76 w I �4A-_X43.56 I o / / rod with ca stamped / \ 6 � " p " p OAK18 OAKt 0 ` o ( \ tQ �O 1 ' A2' II cV FOOT LB 7121 �� X45.27 ` --~' \ \ �AKTWINt01 ( �j N \\ 4252 I I x�t j h, I 6.84 East R/V4 line Northerly L/A i / r- -- X47.08 "`4� R/W line x45.26 / X4588 X4510 '�5\ \ \ \ \ /I I ,.,, wall column I X45.10 \ 1 I `~`-W" cis o s coast ail LID I I I A PAM12 48.9 44.9 X45.71 �, I _ - - X _ OOAKTRIP7 I 44 x49.17 x45.56 x45.12 m X X X X X X X �- X X X X X OAKS x4477 \ I I c �� OOAK24 �C44,02 1 I I of property line 39. 8 4j.o� �ca7. x4717) `90'08�(i6"-1I�1�`4 e8 - - ---- - -542 _ �xaa9i�... - ` `x�s.6s _..- - - -46-- - - - - -X- ��28 �` X / \ // � �S � I \ �8�iglyct'1&_jink fence --47 '�--.� � OAK12 4P.09 -� 48 -49-- - r - -- - - -- - " - - -48-- - - - - .- - -' -' --47- --- . _ - \ tfa I Structure s. 6 x4s.92 _" _ -_ -- - - -49- - - - - ` - - --- - - - - - - - - - - - -' - _ xV `` k 48.37 OOOAKi3 dJOAKd w�i I I drainage ou I 46.01 �. Recovered 5/8" iron _ y So.aax-- - x5o.41i _ .^. X49.98 X49.73 - - - - _ -48- - - _ \. OAK12 I elevation = 41.09a �,,�,,�. OAI� I d Bc a O p ' top ton --49-- - - - - _ - - - - - - _ X49.47 - X49. ` - """"" X r�pe / / Vl � t X41. a Io I top o Skimmer a v. 2.45' ` Fod�l/it 1TD cap - _ - - - - _ ..- .- - - - -49- -`. _ - - - - - - - - - -- $4939`49- - - � � � \ "OAKB \ a`f 0_ � � s J �0 I NW invert - 34.40' tX48.4J 4s' " - -- -- -- - - - - .- _. - - = _ ^^ - - - -48- - _ _ -' - -- -- -- - y = - = _ -' -49- - OOAK6 OOAK26 / / E I 42.a7Y ►" I I 4" PVC bleeder Invert = 39.72' fence comer Is 3.5' r _ _ _ x4s.47 - -- south and 1.5: -welt r -- �. .` _ \ \ •� %` X4S.73 OOAK6 / / OAK16 O I N W ami OAK\ N18 Cr ' o 48.52❑ <• -� -r X47 - - - �r48 iJ X,47 X46.17 - `47- L _X ` ~- � ` \ \ � � X88 X � X44.99 \ / yc _ _ _(� OB `f- �- - - _ - .- -49� .� ` .� ' - - _..,. -. -. - � � � _ X4 16 5 ti 1 � `50.01�\ \ \ ` \ \ � � ` = �� �AK6 / �. � / rn c 1 • I I ".,_edge of water 0.64 �� 123.1 _X 4M \ \--. �_ \ \ �. "" \ 45.36 OAK7 / OOAKTWINS O a o !' L I = '� S�\� \ \ k Recovered 5/8" Iron OAK24 / W / W to I elev. 39.3' 1822. '' .� 5X p.2\ _ �- \ \ rod With CQ atom ed ` /. I M ir w, \ ' vII� I 04 X tf 48 ` \ \ `\ P P 8)OAK8 / OOAK11 �I v W C7 I W rn State Road 417 `' �'\ ` � \ \ \ \ k "FDOT LB 7121" OAKto �,.�(44.96 ( / 0OAKB f I I I Z I Site Benchmark ` ~ �x 30; '` ,\ \ x4 . 0OAK16 OOAKTWINt1111222 J I I 0 DO Limited Access Right of Way Z Recovered Seminole County nail and disk \ OOAK1 ( I I 1= rn per F.D.O.T. R/W Map�¢ \ \ x`2.12 r< I I Z w stamped 813-53-03 in concrete median Section 77160-2441 • \ �.\ \ \ \ \ \ .e'`� \ \ 3 I m : o' top elevation 53.32 R = 825.20 \\�\ \_.� \¢8`��'� �X d Kt4 \ \ \ Q R I I �, cn a D = 27'10'59" \ ` �\¢9` \ \ \\ - _ - - - \ \ a- 0 K8 6�AKy, t \ .�'°`� a- I p I I 10 ao ao L = 391.50 `\`� \ \ �� \ _. - QCs moo` I I I ( I- r • f M \ 43.39 X N CB = N 76 24 30 W. \ �\ \ �-x49:�` \ \ \ \ 1 x s5 i I Z 0 C = 387.84' .¢�\ ` \ \ \ ` \ \ \ \ \ 0014-POAK16 OOAKTW11114 0 I I I W In \ \ `x�� \ \ \ OOAKiS O_ I W «� x�a44 \ \ \ OPALMt ` I \ \ \ \ \ \ \ \ \\ 4\ \ ` -- ~ �¢¢� � \ X4180 N I I 1 � O 40S x48. s \ \ OOAKe \ 110.00" n \ \\ \ \ \ \ \ 6l9AKTWINii I I \ 78 Height of Io 11%.1e X431981 \ \ \ \ \ \ \ \44'con uctor - 63.3 I X\4\ Property DescriptionSurveyors Re ort 4 k OkKTWINIO \� I \ i I I I , 1. Bearings shown hereon are based on the North line of State Road 417, limited access \ \ \ ,�s \ \ �\� OAS\ X44• - i I A parcel of land located in the Northwest 1/4 of Section 33, Township 19 South, right of way, , per Florida De Department of Trans Transportation right ht of way ma Section \ \ o ooA 18 a 1 N y P P P g y P Abbreviations and Legend \\ f �\ % X44.70 Range 30 East, Seminole County,Florida, bean a portion of Lot 1, Pine Lake Groves, as " 9 \ \ gg P 77160-2441 bein assumed as North 90 00 00 West. \ \\ recorded in Plat Book 9, Page 27, Public Records of Seminole County, Florida, as g X4 \\ �C o0 1 Structure {� A49X7 I recorded Official Record Book 4447, Page 1085, Public Records of Seminole County, F.D.O.T. - denotes Florida Department of Transportation \ \ \\ �' \ \"� I height of 1. eat wire Florida, being more particularly described as follows: 2. The elevations shown hereon are based on Seminole County Vertical Control Network. \ \ \\ \ \ at conductor - 62.4' I I I Specifically, benchmark designation number 8135303, being a Seminole County nail and L/A - denotes limited access \ \\ \ \\ \ \ \ i disk stamped 813-53-03 in concrete median of entrance to State Road 417 125' east \ \ \ 34 \ \\ ) i I I I I edge of water A portion of Lots 1 and 2, Pine Lake Groves, according to the Plat thereof as recorded \ \ � k elev. = 39.3' in Plat Book 9, Pae 27, of center line of Reinhardt Rcad Published elevation is 53.32 feet relative to the North \\ \ Page Public Records of Seminole County Florida, lying in the R/W- denotes right of way \ � \ \\ \ \ \ \ 44.79 I I I Northeast 1/4 of Section 32, Township 19 South. Range 30 East, and the Northwest 1/4 American Vertical Datum (NAVD) of 1988. of Section 33, Township 19 South, Range 30 East, as recorded in Official Records Book O.R.- denotes Official Records Booker 1265, Page 1570, Public Records of Seminole County, Florida, p lying 3. This Survey was performed with the benefit of a title commitment prepared by Old \ \ \ D \ \ XIt;4.4A\ \ \ less that portion I in in \ '\ '� \ �`� x44.03 Republic National Title insurance Company, commitment number 510261, dated October P.B. - denotes Plat Book '� \ \ \1614 k \ \ Reinhardt Road 140 -foot ri ht-of=wa as shown on Florida Department of Northerly L/A \ \ \ ¢ h P 18, 2017. This firm relied on said commitment for easements and restrictions of record R W line \91°\ \ \'0"a�'w„ west face of wall is Transportation Right of Way Map Section YNo. 77160-2441, and did not search the public records for easements or restrictions of record. p . - denotes Pae / \ \ \ \ \ ii�k x�4.5e\ \ 0.9 east of property line Pg.- g Storm drain manhole � \ \ \ \ f�c �iioli colurl\n \ � Bein more articular) described as follows: top elev. = 48.35' X4.44 \ \ \ \¢ 7 X \ \ Being particularly 4. Subject property contains 7.718 acres, more or less and is currently vacant land. LB- denotes Licensed Business S invert •. 40.10' (18" RCP) \ \ IN, \ e\ k • p -denotes electrical box N invert = 3s.62' (18" RCP) \ � \ �q�,r \ \\ From the Northwest corner of said Section 33, Township 19 South, Range 30 East, (a 5. Subject property lies within Zone X, area determined to be outside the 0.2% annual i P P Y PSM - denotes Professional Surveyor and Mapper Alk 5"concrete monument as now exists), run thence North 89'5239" East along the North chance floodplain, according to the National Flood Insurance Program, Flood Insurance ®- denotes telephone riser box IN, \ \ \ \ \ \ XV 34 \ \ line of said Section 33 a distance of 1318.88 feet to a point on the East line of said Rate Map number 12117C0065F, dated September 28, 2007. PRM denotes permanent reference monument \ \ \ \ e Benchmark Pine Lake Groves, according to the Plat thereof as recorded in Plat Book 9, Page 27,®- denotes light pole on concrete base \ \ \ \ \ \X44.99 Recovered 4" x 4" concrete Public Records of Seminole County, Florida; thence South 00'25'04" West along the East 6. Only the trees that are 6" In diameter at breast height and larger are shown hereon. Inv. denotes invert x4i;2s� \ monument with disk stamped line thereof 30.00 feet to the Northeast corner of said Lot 1 for the POINT OF Only the trees within the subject property are shown, there may be trees within 5' of O - denotes traffic light support pole \ \ \ \ 'PRM LB 68' BEGINNING; thence continue along the East line of said Lot 1 South 00'25'04" West the boundary lines that are not shown. The location of the trees shown hereon are elev. - denotes elevation \ \ \x4`7$ top elevation = 44.27' 487.21 feet to a point on the Northerly existing limited access right of way line of State approximate and not intended for design purposes. If trees are to remain due to ®-denotes underground utility pullbox X46.35 Road 417 (Parcel 320 Part C) as shown on Florida Department of Transportation Right of Way Map, Section 77160-2441; thence North 6249'00" West along said right of way line 450.59 feet to the beginning of a curve concave Southerly, having a radius of 825.20 feet, a central angle of 27'10'59" and a chord bearing of North 76'2,00" West; thence Westerly along the arc of said curve and said right of way line 391.50 feet for the end of said curve; thence continuing along said right of way line South 90.00'00" West 530.45 feet to a point on the East line of said Reinhardt Road, being a point on a curve concave Westerly, having a radius of 2616.47 feet, a central angle of 04'06'35" and a chord bearing of North 02'43'16" East; thence Northerly along the arc of said curve and said East line of Reinhardt Road 187.67 feet to a point on the North line of said Lot 1; thence, departing said East line of Reinhardt Road, North 89"52'39" East along said North line of Lot 1 a distance of 1302.90 feet to the POINT OF BEGINNING. Containing 7.718 acres, more or less. proposed design, we recommend a more accurate location of the trees trunk and roots. 7. Only the aboveground evidence of underground utilities are shown, underground improvements were not located, unless shown. 8. The spot elevations along the edge of pavement/curb are edge of pavement elevations. 9. The feature symbols depicted on this survey and in the legend are shown for graphic purposes and may not be drawn to scale. 10. This Survey was performed for the sole and exclusive benefit of the entities listed hereon and shall not be relied upon by any other entity or individual whomsoever. 11. This survey meets the Standards of Practice set forth in Florida Administrative Code Rule 5J-17, pursuant to Florida Statute Chapter 472. 12. A paper original of this Survey is not valid without the signature and original raised seal of a Florida licensed surveyor and mapper and a Portable Document Format (PDF) file version of this survey is not valid without a digital signature and seal of a Florida licensed surveyor and mapper. RCP- denotes reinforced concrete pipe CPP - denotes corrugated plastic pipe PVC - denotes polyvinyl chloride material ® - denotes storm drain manhole ® - denotes storm drain inlet D-5 - denotes storm drain structure number (Tyr) - denotes top of wall -� - denotes guy wire anchor gyp, - denotes wood utility pole - denotes concrete power pole for high transmission power line �---- - denotes wood post guy wire anchor O - denotes set 5/8" iron rod with cap stamped 'PSM 5205', unless otherwise noted -u- - denotes stop sign or handicap parking sign i X 126.50 - denotes spot elevation x•124-- = denotes contour line and elevation OOAK13 - denotes oak tree and size of diameter at breast height in inches (ex. 13" oak tree) 0 OAKTwIN7 - denotes twin trunk oak tree and size of diameter at breast height in inches OPINE21 - denotes pine tree and size of diameter at breast height in inches (ex. 21" pine tree) OMAGB - denotes magnolia tree and size of diameter at breast height in inches (ex. 6" magnolia tree) 0PALM9 - denotes palm tree and size of diameter at breast height in inches (ex. 9" palm tree) o crP8 - denotes cypress tree and size of diameter at breast height in inches (ex. 8" cypress tree) Storm Structure Table D-1 Inlet D-6 inlet Top slay. = 47.59' Top elev. - 44.20' NW invert - 41.09 (36" RCP) Bottom elev. - 30.26' E (water elev. in structure Is 36.2', D-2 manhole unable to see pipes for measure) Top elev. - 48.56' N SE invert - 39.86' (36" RCP) D-7 pond outfall structure N invert = 40.06' (36" RCP) Top elev. - 35.86' Rr- Skimmer elev. - 36.40- D-3 inlet Top elev. = 45.48' N invert - 33.30' (6" PVC orifice) E invert - 36.35' (30" RCP) S invert - 31.56 (24" RCP) slot elev. = 35.00' N invert - 35.68' (30" RCP) 0 D-4 inlet D-8 inlet Top elev. - 36.98' Top elev. - 43.48' bottom elev. - 31.50' W Invert - 39.48' (30" RCP) (inlet still has felt paper D-5 inlet covering bottom of grate) Top elev. = 42.53' D-9 manhole and curb inlet Bottom elev. - 29.27' top of manhole elev. - 48.57' (water elev. In structure is 36.2', N invert - 43.57' (18" RCP) unable to see pipes for measure) S invert - 43.77' (18" RCP) (Invert information taken from asbullt survey provided by the client) Test Hole Table Test Hole # 1 - Re -use Water line 12" PVC - top elevation - 41.8' surface elevation = 46.8' Test hole 4 2 - Electric line 4 1/2' PVC - top elevation = 44.4' surface elevation - 46.8' Test hole # 3 - Water line 12" DI pipe - top elevation = 42.2' surface elevation = 46.5' Test hole 4 4 - Gas line 2 1/2* Poly - top elevation = 43.5' surface elevation = 46.4' Test hole # 5 - Communication line 1/4" double cable - top elevation - 43.2' surface elevation = 46.1' Test hole # 6 - Sanitary force main 8" PVC - top elevation = 43.4' surface elevation = 47.2' Test hole # 7 - Communication line 2" double cable - top elevation = 44.9' surface elevation = 47.3' u0 co 0 L a� CI CL Q 1, C: LO 00 0 qk > C a c c � C U O J •0 'O 0 M a � A 0 Lli W 0 0 L a. C" U)o� ° -O_a 0 OO a O o�m Q)O++ ) 0 G� C Q_ C: O L O LTJ •-- N C CL> - O vow°Q) UJ~ (n Y. vi O _J n M UJ Z.0 V) N N 2�►- V m a o L U v, .o 0 E w o a �Q o, o 0 rn i7 o 3 o c 0 E a c 00 a1 o I 01 0 0 v v N °v v 4a C v m ao 00 ca M 0 v 04 d M V 0 O t- o E 0 L Z it N \ 0 �o Rr- Q1 rn Ii.- CL N Sheet 1 of 1 N \ I O O N N (0 N m 0 N Z Sheet 1 of 1 II �I I II II boo rZ I i Two 03 II Ira a inlet I I Point of Commencement Northwest corner of the Northwest 1/4 of Section 33, Township 19 South, flange 30 hast, Recovered nail and disk in pavement. st:arnped # 065370 I V ' 1 1 1 Lot 1 BEST BUY ON RINEHART ROAD Plat Book 66, Pages 49-50 ' Best Ruy building floor ales, = 4.6,1' concrete 91 eWa k II�..F U T T I L ....� ncrete �� 1 II IIII��II�.� AERIAL FIRE TRUCK -- �� osphait 'I arco lvewoy asphalt driveway and pork'ng lot U_5 - edge of pavemenk curb Ff(1AK U ` Ki 1 nnAKt Kim K•I%.�S 0AK� OLAG%.. r.rti pr..IvIAG7r�" 4 �� - ��� �� �� �• •� U K11 R'� -2 r -.- �or- J ina-a# S4E±t+orl r edge of water_..,, ` edge of water concrete retaining wall edge of water elev. •• 35.2' 43.42(1-0 � G�■ V. 0r I °~ GRAPHIC SCALE v U ( c ( Lot 1, WAL-MAR1' GATE CONTR -`1 PI RSI'ORE ON RINEHART ROAD /STACKEDST i. �.�W�ii ( IN FEET ) 1 inch - 50 ft. Plat Book 65, Pages 31-•-32 I C Water' - 3.5' a I 1 BIKE RACK (2 SPACES) " Ei. link f_ ce X"-��" "i3•(2d4d 3J" 0.-.v.-.,,., � r .■il �.5- �..�....-C�..•.....■.�� V I _1 ` Bl7fC01NS Teak1 r 7 -- r� oQar- - - - - - -t ales. 44.02' / I ( rr�.� I / i I OG TW NB�` I y'. I ;. 4 y. 5r .<nnn ivr ' I II ( I(I I dh - - I II ....- I ..'1..'PE' r� AARyu y x30" RCP) nvert 39.00' - x30" RCP OOAK289 --in link fence NOrth i'na of Lot 1 Pine Lake ,! .. iur f fs;U,. j _ • I +kD I endoLith of corner Groves, Plat Book 9.fase 27 y .. o. o' '• • �' •k � 1�>� f 3 Y � rz'�� � J�3 ,H�yyU���yWt► OOAK6 --fo. I I Ix�S'r�>; rrs z s .f r K° ryra AERIAL FI TRUCK 94 OOAK6 IY k is y. S i2 Y / 3f k. F i f .y: S J..:. ys ` 7 r. :4 . •J•J 1 . . Y...Y r- s k n � 1 v •� 4 j Y �.: '.3.r'Yt. M.. y• K ). AKB i N I ,00 • OAK6 .'� �IN �------- lJ l ( o n ?' i' cc '•�• I � -- I Q m � I I.• i �ti .3 r � ;sx � r� �� ` � � r� ), CRY , ,f �� '� r'' I ZI I m J x OOAKTw'Ni .'use• n k Fjr .�. r•: r I( v 19 I oAKTwN6 3 PROPOSED LOT 2 v f d1 ora 'I z�I II1 • cQ I tII .riiYk a�Rrytrn;°pi. i''rrSkrtY'yird�k . rs ' SFPs x.+?ietiM�3YsV'{s$onKa ooAKTvN-s` r0 V) 5PROPOSED LOT 1 LIFT STATION �rphTJkrF'0AK12• 3, /�I �>•�PPnryzf. t' U cr�f Lot 'ortGENERATOR m OAK TWIN %o N14OPALMI4 OAKi UOAK6GROVES y t Js >., AKSf3 CINELAKE v_OV[J m CL OAKS $ UOAKGATE CONTROL�.�, Q, ,a p L_ r U-1 't 1` nJ 6 �1" •a y -^tet . �� '�PEDESTAL Vacant Land OfUnI IIIIII IIIIII .•�F,..F•/.1 .•..' ( 1 J_ky:JS >rIr rf[yyls i a;y}rr £r 1%sr a r. wY�rkt a>2iFrr,s,YYy�kr✓ rz " r Ya rkY1ird�ybriye Il�fYr � "fY mOOAK12 jW 0OAK13 J��s N a m V / MONUMENT SIGN . I /n .� tFaR5lYrik'raIstt - 'Yc's. �31,Crt�v1{jr rYrYYrkrer1t i/>r rys rrrr{lr ;'.,r> k♦yri"»i>t r�'�Y"a' lrJJ�k ^ h S: '. rsS � • �•I•• ri IpyY rzmrod with cap stamped p 20 BUILDING SETBI " DCi1B_71Z1 'X­­ >st R/W lineNortherly L/A ire.W.gUff�------- i� `L ---------A-------.--- 1,7 b�Ai6 i -C -d Y 6 h�X �C-p--.---- s'ke OAKS � v t1 s OOAKT k-6' high chain link fence "`••••.."""`.i� '�•� Sd �► `aL 3 T 1 P r) I C `""n."'""'a••"n. OAK12. 3 !Y t , dk ts�Gy ,� w ' I 1 OOOAKI3 I I Ks 3 i ks rj u aI Recovered 5/8 iron o ` rad with n0 Ca r r �, x Y ?k Y •'• ' fence donne!' o Rp \�AKB � 1south and 1,5' west OOAK6 H i �r ♦ \ �\ 0OAK6 I I I AS r{ tart �/s s -gar r"` s w Y rsY �': f <r ...••I , f - I .-• 0 I s tt 7 r i :1. >F• "+ x ksrir4 £ �s. >r'iGY,. k. L fi1r; ` Y; 3'� ii4s h Ai: ? �' r x, r4 J .Ef4 iAK6 AERIAL FIRE FOR 6 :iRUCcovers ' .. ...... (1e~ RCP) with C 7 x • 7' (1 t3" RCP) I h "FDO. , }' I YYY Site Benchmark '�\ \ �:.. --: : : a _ Lirniied Access Right of Way ,t line of Section ' 33 �� l , �.; •. ;;, Recovered Seminole County nail and disk , 0.'' R W N 6 BLACK ( "�"'"" " �r'F "°"ter"' ti ^y I stamped 813-53-03 in concrete median per f'.i y / sap ' ` J " `� _..: top elevation - 53.32' Section 7`160"' 2441 CHAIN LINK FE \ h4 ` xr r } yJ' s ...• t5.86' s 'x1 ::::..:.'.:I.i:::.) .. ... GENERAL NOTES GENERAL INFORMATION: : GROUND IGN yfY, PROPERTY INFORMATION: � �'� 1 l 1. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANIES PRIOR TO ANY CONSTRUCTION ACTIVITY FOR DIG MAX. HEIGHT 15' \rfJr T x ` S• �` r. Jr rw •. PERMITS, ELECTRICAL PERMITS OR OTHER PERMITS AS APPLICABLE. CONTRACTOR IS ALSO TO COORDINATE FULLY WITH UTILITY COMPANIES ON EXACT LOCATION OF UNDERGROUND UTILITIES AND ANY UTILITY ADJUSTMENT REQUIRED. UTILITY COMPANIES SHALL BE NOTIFIED A MINIMUM OF THREE WORKING DAYS PRIOR TO EXCAVATION. 2. THE LOCATION OF EXISTING UTILITIES SHOWN ON THESE PLANS WERE DEPICTED FROM ACTUAL FIELD MEASUREMENTS AND/OR DERIVED FROM RECORD DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONFIRM THE LOCATION OF EXISTING UTILITIES TO DETERMINE IF THERE ARE ANY CONFLICTS WITH THE PROPOSED CONSTRUCTION AND TO COORDINATE WITH THE UTILITY OWNERS TO RESOLVE THESE CONFLICTS. 3. THE SUBSURFACE INFORMATION FOR THIS PROJECT WAS OBTAINED FOR DESIGN PURPOSES AND MAY NOT BE AN ADEQUATE REPRESENTATION OF ACTUAL CONDITIONS FOR PROJECT CONSTRUCTION. INFORMATION SHOWN, INCLUDING WATER LEVELS, REPRESENTS EXISTING CONDITIONS AT THE SPECIFIC BORING LOCATIONS AT THE TIME THE BORINGS WERE MADE. 4. ANY DIFFERING SITE CONDITIONS FROM THAT WHICH IS REPRESENTED HEREON, WHETHER ABOVE, ON OR BELOW THE SURFACE OF THE GROUND, SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER, IN WRITING, WITHIN 48 HOURS OF DISCOVERY. NO CLAIM FOR EXPENSES INCURRED BY THE CONTRACTOR DUE TO SUCH DIFFERING CONDITIONS WILL BE ALLOWED IF HE OR SHE FAILS TO PROVIDE THE WRITTEN NOTIFICATION. 5. ALL MATERIALS, INSTALLATION AND TESTING SHALL BE IN ACCORDANCE WITH THE CITY OF SANFORD, FLORIDA BUILDING CODE AND FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. 6. THE CONTRACTOR SHALL PROVIDE ALL SHEETING, SHORING AND BRACING REQUIRED TO PROTECT ADJACENT STRUCTURES AND UTILITIES OR MINIMIZE TRENCH WIDTH AS REQUIRED. SHEETING AND SHORING SHALL BE DESIGNED BY A STATE OF FLORIDA PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR. 7. THE CONTRACTOR SHALL ENSURE THAT ALL REQUIRED CONSTRUCTION PERMITS HAVE BEEN OBTAINED PRIOR TO COMMENCING WORK. 8. ALL DEBRIS AND WASTE MATERIALS GENERATED BY DEMOLITION OR SUBSEQUENT CONSTRUCTION ACTIVITIES SHALL BE DISPOSED OFF-SITE IN A LEGAL MANNER AT AN APPROVED DISPOSAL FACILITY. THE CONTRACTOR SHALL OBTAIN ANY AND ALL PERMITS REQUIRED FOR DEMOLITION, CONSTRUCTION WORK AND HAULING WASTE MATERIAL ALL ASSOCIATED COSTS AND PERMIT FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 9. ANY PUBLIC LAND CORNER, WITHIN THE LIMITS OF CONSTRUCTION, IS TO BE PROTECTED. IF A CORNER MONUMENT IS IN DANGER OF BEING ALTERED AND HAS NOT YET BEEN PROPERLY REFERENCED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER WITHOUT DELAY. 10. COORDINATE VALUES ARE BASED ON A LOCAL GRID ESTABLISHED BY THE ENGINEER AND ARE INDEPENDENT OF VALUES DEPICTED ON THE SURVEY. 11. ALL REFERENCES TO PROPOSED CONSTRUCTION INDICATES CONSTRUCTION INCLUDED IN THIS CONTRACT. 12. ALL PIPING TO HAVE A MINIMUM OF THREE (3) FEET COVER UNLESS OTHERWISE NOTED ON PLANS. 13. THE CONTRACTOR SHALL FURNISH, ERECT AND MAINTAIN ALL NECESSARY STRIPING, TRAFFIC CONTROL AND SAFETY DEVICES IN ACCORDANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES," LATEST EDITION, AND THE LATEST FLORIDA DEPARTMENT OF TRANSPORTATION "ROADWAY DESIGN STANDARDS." 14. MAINTENANCE OF TRAFFIC: ACCESS FOR LOCAL TRAFFIC SHALL BE MAINTAINED. IF, DURING CONSTRUCTION, ACCESS FOR LOCAL TRAFFIC IS CHANGED, 'THE CONTRACTOR SHALL NOTIFY THE APPROPRIATE JURISDICTIONAL AGENCY A MINIMUM OF THREE (3) WORKING DAYS IN ADVANCE. MAINTENANCE OF TRAFFIC SHALL BE IN ACCORDANCE WITH INDEX NO. 600 OF THE FLORIDA DEPARTMENT OF TRANSPORTATION ROADWAY AND TRAFFIC DESIGN STANDARDS. 15. REFER TO FDOT ROADWAY AND TRAFFIC DESIGN STANDARDS FOR THE FOLLOWING: A. TYPE "C" INLET (INDEX NO. 232) B. TYPE "E" INET (INDEX NO. 232) C. TYPE "P" MANHOLE (INDEX NO. 200) D. TYPE "J" MANHOLE (INDEX NO. 200) E. TYPE "J" BOTTOM (INDEX NO. 234) F. TYPE "D" CURB (INDEX NO. 300) G. TYPE "F" CURB AND GUTTER (INDEX NO. 300) H. CURB RAMP (INDEX NO. 304) I. CROSSWALK, STOP BAR (INDEX NO. 17346) J. PAVEMENT ARROWS & MESSAGE SIZE & SPACING (INDEX NO. 17346) K. CONCRETE BUMPER GUARD (WHEEL STOP) (INDEX NO. 300) 16. AS -BUILT DRAWINGS, SIGNED AND SEALED BY A LAND SURVEYOR REGISTERED IN THE STATE OF FLORIDA, SHALL BE PROVIDED PER THE PROJECT SPECIFICATIONS AND SHALL COMPLY WITH CITY OF SANFORD REQUIREMENTS. rnen®fne : 6iuu zkge roan - tananart gammons rrili rim vaso : uun. Lias AUID tcuL)pm PHASE .ONE (1) PROPOSED USE: SELF STORAGE AREA CALCULATIONS: TOTAL PROPERTY AREA: 8.61 AC. LOT 1 - 2.35 AC. I aI LOT 2 - 278 AC. I I LOT 3 - 3.48 AC. 48.20 Q TOTAL AREA: 374,901 SF (8.61 AC) MAX. PERMITTED ISR (PD): 0.80 TOTAL IMPERVIOUS AREA: 101,803 SF (2.34 AC) - 27.2% MINIMUM OPEN SPACE (PD): 20% i�rbuilding OPEN SPACE: 273,098 SF (6.27 AC) - 72.8% BUILDING INFORMATION: SELF -STORAGE BUILDINGS: BUILDING HEIGHT: STRUCTURE A: 41'-6" STRUCTURE B: 10'-4" STRUCTURE C: 10'-4" 3 -STORY STRUCTURE A LEVEL 1 - 33,494 SF LEVEL 2 - 33,494 SF LEVEL 3 - 33,494 SF TOTAL STRUCTURE A - 100,482 SF STRUCTURE B - 7,952 SF STRUCTURE C - 4,641 SF MTAL SELF -STORAGE - 113,075 SF MAX. PERMITTED FAR (PD): 0.50 m FAR: 113,075 / 374,901= 0.30 MAX. PERMITTED BUILDING HEIGHT: 8 STORIES, UP TO 100 FT AERIAL FIRE TRUCK DIMENSIONS WHEEL BASE - 249 INCHES KINGPIN CENTERS - 68.5 INCHES FRONT TRACK - 80.7 INCHES BODY FRONT OVERHANG - 86 INCHES BODY WIDTH - 96 INCHES BUMPER TO BUMPER LENGTH - 511 INCHES MAXIMUM INSIDE CRAMP ANGLE - 44 DEGREES NOTE: UNOBSTRUCTED VERTICAL CLEARANCE OF AT LEAST 13 FEET 6 INCHES SHALL BE PROVIDED FOR ALL DEPICTED TRUCK ROUTES, (TYPICAL) CITY OF SANFORD - CONDITIONS OF APPROVAL: ON MARCH 26, 2018, THE CITY COMMISSION ADOPTED ORDINANCE NO. 4444 REZONING PROPERTY AT 1451 RINEHART ROAD TO PD, PLANNED DEVELOPMENT CREATING THE RINEHART GREENWAY COMMONS PD, SUBJECT TO A DEVELOPMENT ORDER WITH THE FOLLOWING CONDITIONS: 1. PURSUANT TO SECTION 4.3.G OF THE LDRS, THIS REZONING SHALL EXPIRE 3 YEARS FROM THE EFFECTIVE DATE OF THIS ORDINANCE IF ALL IMPROVEMENTS HAVE NOT BEEN COMPLETED OR AN EXTENSION GRANTED. 2. ALL DEVELOPMENT SHALL BE CONSISTENT WITH RINEHART GREENWAY COMMONS PD MASTER PLAN, DATED AS RECEIVED BY THE CITY ON FEBRUARY 2, 2018 INCLUDING, BUT NOT LIMITED TO, THE GENERAL STANDARDS AS ESTABLISHED ON THE CONCEPT PLAN UNLESS OTHERWISE SPECIFICALLY SET FORTH IN ANY ASSOCIATED DEVELOPMENT ORDER; PROVIDED, HOWEVER, THAT ALL SUBSEQUENT DEVELOPMENT ORDERS SHALL BE CONSISTENT WITH THE PROVISIONS OF THIS ORDINANCE. 3. ALL LAND USE ACTIVITIES CONDUCTED ON THE PD PROPERTY SHALL BE IN ACCORDANCE WITH SCHEDULE 'B" - PERMITTED USES, OF THE LDRS FOR THE GC -2, GENERAL COMMERCIAL, ZONING DISTRICT: THE MR -3, MULTIPLE FAMILY, ZONING DISTRICT NOTED ON THE PLAN SHALL NOT APPLY. TOWNHOMES AND OR MULTIPLE FAMILY RESIDENTIAL MAY BE ESTABLISHED BY WAY OF A CONDITIONAL USE. ALL ACTIVITIES SHALL BE CONDUCTED INDOORS, INCLUDING ANY STORAGE OR ASSEMBLY. 4. THE PROPERTY OWNER SHALL FORMULATE AND MEMORIALIZE WITH STAFF A DOCUMENT, APPROVED BY THE CITY ATTORNEY AND OF EQUAL DIGNITY HEREWITH, CREATING A LANDSCAPING BARRIER IN THE BUFFER AREAS LOCATED BETWEEN THE RESIDENTIAL AND COMMERCIAL/INDUSTRIAL USES SUCH ACTION TO OCCUR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 5. AN OVERALL COMPREHENSIVE SIGN PLAN SHALL BE ESTABLISHED AS REGULATED IN SCHEDULE 1(; SIGN REGULATIONS, OF THE LDRS. THE SIGNAGE SHOWN ON THE RINEHART GREENWAY COMMONS PD MASTER PLAN IS CONCEPTUAL AND NOT APPROVED IN CONJUNCTION WITH THIS ORDINANCE. ALL SIGNAGE WILL BE REVIEWED AND APPROVED SEPARATELY. 6. ALL REQUIREMENTS RELATING TO TREE MITIGATION AS ESTABLISHED IN THE LDRS SHALL BE MET PRIOR TO DEVELOPMENT OF THE PD PROPERTY. 7. A DECORATIVE AND FUNCTIONAL FOUNTAIN SHALL BE INSTALLED IN ALL WET RETENTION PONDS BY THE PROPERTY OWNER AS PART OF DEVELOPMENT APPROVAL WHICH APPROVAL SHALL PROVIDE FOR ONGOING MAINTENANCE REQUIREMENTS AND RESPONSIBILITIES UPON THE APPROPRIATE PARTY, AS APPROVED BY THE CITY, BUT NOT THE CITY. 8. ALL COMMERCIAL ELEMENTS OF THE DEVELOPMENT SHALL BE IMPLEMENTED IN ACCORDANCE WITH SCHEDULE 'G" - ARCHITECTURAL DESIGN STANDARDS, OF THE LDRS. 9. UNLESS SPECIFICALLY APPROVED ON THE RINEHART GREENWAY COMMONS PD MASTER PLAN, ANY CONCEPT PLAN OR A DEVELOPMENT ORDER, ALL REQUIRED ELEMENTS MISSING FROM OR NOT SHOWN ON THE RINEHART GREENWAY COMMONS PD MASTER PLAN SHALL COMPLY WITH THE LDRS. 10. THE FOLLOWING DESIGN ELEMENTS WILL BE CONSIDERED DURING THE DEVELOPMENT PLAN REVIEW: A. SITE IMPROVEMENTS OCCURRING ON THE PD PROPERTY MAY INCLUDE THE INCORPORATION OF LOW IMPACT DEVELOPMENT (OFTENTIMES REFERRED TO AS 'UD J TECHNIQUES AND CRIME PREVENTION THROUGH ENVIRONMENTAL DESIGN (OFTENTIMES REFERRED TO AS "CPTED) GUIDELINES. B. ELEMENTS OF BUILDINGS MAY BE CONSTRUCTED INCORPORATING LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN (OFTENTIMES REFERRED TO AS 'LEEDJ, FLORIDA GREEN, OR SUCH OTHER EQUIVALENT ENERGY SAVINGS STANDARDS AS MAY BE APPROVED BY THE CITY. C. UNLESS SPECIFICALLY REQUESTED AND APPROVED ON THE PD MASTER PLAN, ANY REQUIRED ELEMENTS MISSING FROM OR NOT SHOWN ON THE PD MASTER PLAN SHALL COMPLY WITH THE LDRS. 11. THE RESOLUTION OF ALL DISPUTES ARISING FROM DEVELOPMENT UNDER RINEHART GREENWAY COMMONS PD SHALL BE RESOLVED BY • THE PLANNING AND ZONING COMMISSION UNLESS OTHERWISE SPECIFICALLY PROVIDED BY CONTROLLING LAW. drainage inlet Top elev. 38.40' W Invert " 31.20' (42" RCP) N invert 31.00' (42" RCP) S 00.25'04" W .30,00' line of Lot 1, Pine Lake Groves, 1''at Book 9, Page 27 f' 1 r o ni .�f Beginning Northeast line of Lot 1, Pine Lake JD V die - 39.55' tL�C :m - 33.7 -r I 1 40, 9= I aI Groves, ti"lat Book 9, Page 21 I I plot scale: 48.20 project number: I �I •5' high metal rail fence I�I W El -I II WI z 1 I i�rbuilding retaining wall c: +;n a o' I) 0-I dr inage iniet JD V die - 39.55' tL�C :m - 33.7 -r I 1 40, 9= C Okil8 l l \ Our MAR TENANCE DOU ILE 6 SWI1 G GATE ��. 6' LACK VINYL -CH IN LINK FENCE L) Northerly L/A4 -..... 'b R/W lint; ) aff ofh%n` Storm drain manhole/ ort�ert fllnk� lop elev. s, 48.35' � Q rS invert •• 40,10' (18° RCP) N invert •* 39.82' (18" RCP) PAVING LEGEND: CONCRETE WALKS, PADS AND PAVEMENT ° (REFER TO DETAILS ON SHEET C600) ASPHALT PAVEMENT SECTION • (REFER TO DETAIL ON SHEET C600) 0 PARKING DATA: ` 45.71 5' hick metsl rail feriae drainage outfall top 0evat on = top OF skimmer NW invert - 34, 4' PVC Weede- edge of waiter /� elev. 30.:5' Iw� O al CI r•� 7"', Z) 7 of fl1 Z /01 Q '4 IC) •n Ldm 111 +• CL, a -edge of water elev., _ :59.3' !.45' 9.72' - _..,._........,..._ __ west face of wall i9 0.9' east of property line Sall column Site Benchmark Recovered 4" x 4" concre monument with disk stam 'PRM LB 68' top elevation = 44,27' CITY OF SANFORD PARKING REQUIREMENT BASIS: (SCHEDULE H) SELF -STORAGE FACILITY: MINIMUM NUMBER OF PARKING SPACES REQUIRED PER UNIT = 6 PARKING SPACES TOTAL PARKING REQUIRED: 6 SPACES PARKING PROVIDED: REGULAR ACCUSIBLE TOTAL STORAGE TOTAL PARKING PROVIDED 4 2 g BICYCLE PARKING REQUIREMENTS: BASIS: (SCHEDULE H) ONE BICYCLE SPACE FOR EVERY 20 PARKING SPACES, A MINIMUM OF 2 SPACES. TOTAL BIKE PARKING REQUIRED: 2 SPACES i 2 SPACED (1 RACK) Nit ru ,0 U 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Certificate of Authorization No.: 9230 l11 1 1 1 l t C6�j_ e•••••■••r� � Imo, • • w' • • • O r to e ■■• ��•• s i.d,7 w ..r • r • er OF wJ Selby G. Weeks 56991 t C) U 0 r� 0 � % h WJ 1 � 0 U i revision 0 0 0 description date Owner Revision 03.28.18 drawn by: RVZ aI SGW date: 03/09/18 plot scale: �I project number: I �I x-36x24Title Vlk-Rinehmtdwg as CN U I I c: +;n a o' o La cv 4 »= ^1 welt rnlumn N r, N ty d n`west facie of we Is 0.9' east- I -1 c), 0 I Z of property lin Qf I q _�- Qi , to I a• n? c� 'U ami O rrt .Y. co W :- ? 'a N O _ t _...... I LZ 1l3 � J n � 1_..i I I m� I o Iv �I� AI•tICL -10.671 u ( 10 Ili_ I I 10.00' i "�i II OAK18 rl C Okil8 l l \ Our MAR TENANCE DOU ILE 6 SWI1 G GATE ��. 6' LACK VINYL -CH IN LINK FENCE L) Northerly L/A4 -..... 'b R/W lint; ) aff ofh%n` Storm drain manhole/ ort�ert fllnk� lop elev. s, 48.35' � Q rS invert •• 40,10' (18° RCP) N invert •* 39.82' (18" RCP) PAVING LEGEND: CONCRETE WALKS, PADS AND PAVEMENT ° (REFER TO DETAILS ON SHEET C600) ASPHALT PAVEMENT SECTION • (REFER TO DETAIL ON SHEET C600) 0 PARKING DATA: ` 45.71 5' hick metsl rail feriae drainage outfall top 0evat on = top OF skimmer NW invert - 34, 4' PVC Weede- edge of waiter /� elev. 30.:5' Iw� O al CI r•� 7"', Z) 7 of fl1 Z /01 Q '4 IC) •n Ldm 111 +• CL, a -edge of water elev., _ :59.3' !.45' 9.72' - _..,._........,..._ __ west face of wall i9 0.9' east of property line Sall column Site Benchmark Recovered 4" x 4" concre monument with disk stam 'PRM LB 68' top elevation = 44,27' CITY OF SANFORD PARKING REQUIREMENT BASIS: (SCHEDULE H) SELF -STORAGE FACILITY: MINIMUM NUMBER OF PARKING SPACES REQUIRED PER UNIT = 6 PARKING SPACES TOTAL PARKING REQUIRED: 6 SPACES PARKING PROVIDED: REGULAR ACCUSIBLE TOTAL STORAGE TOTAL PARKING PROVIDED 4 2 g BICYCLE PARKING REQUIREMENTS: BASIS: (SCHEDULE H) ONE BICYCLE SPACE FOR EVERY 20 PARKING SPACES, A MINIMUM OF 2 SPACES. TOTAL BIKE PARKING REQUIRED: 2 SPACES i 2 SPACED (1 RACK) Nit ru ,0 U 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Certificate of Authorization No.: 9230 l11 1 1 1 l t C6�j_ e•••••■••r� � Imo, • • w' • • • O r to e ■■• ��•• s i.d,7 w ..r • r • er OF wJ Selby G. Weeks 56991 t C) U 0 r� 0 � % h WJ 1 � 0 U i revision 0 0 0 description date Owner Revision 03.28.18 drawn by: RVZ checked by: SGW date: 03/09/18 plot scale: AS SHOWN project number: 17RINEool file name: x-36x24Title Vlk-Rinehmtdwg et f1, 3 DUMPSTER ENCLOSURE RWEhiART SS ASSOCIATES LLC 1451 RINEHART ROAD; 5ANf:ORD, FL 32771 i T. h-0 Ln 9 9 9 9 V STOPi i n i i i i i i Z. -I IT TFITIT SITE PLAN (FOR REFERENCE ONLY) aoo���a���ao �>•oo�a� a GENERAL THE GENERAL CONTRACTOR SHALL REVIEW AND DETERMINE THAT ALL DIMENSIONS ARE MASONRY COORDINATED BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO MASONRY CONSTRUCTION, MATERIALS, AND INSPECTION SHALL CONFORM TO THE COMMENCING WITH THE FABRICATION OF MATERIALS OR THE START OF CONSTRUCTION. MINIMUM REQUIREMENTS OF THE LATEST ADOPTED EDITIONS ACI 530 & 530.1, ASCE THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT THE 5 & 6, IMS 4H & 602, ASTMESE CONTRACT DOOCUCU & C1019, AND NCMA TEK 107, UNLESS SPECIFIED IN TH STRUCTURE, THE WORK PERSONS, AND OTHER PEOPLE DURING CONSTRUCTION. HE SHALL MENTS. SUPERVISE AND DIRECT THE WORK AND BE RESPONSIBLE FOR ALL CONSTRUCTION. CONCRETE BLOCKS SHALL CONFORM TO THE MINIMUM REQ. OF ASTM C-90 WITH NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE REDUCED IN STRENGTH. f m=1,500psi (1,900psi ON THE NET AREA) THE GENERAL CONTRACTOR SHALL COORDINATE ALL DESIGN PROFESSIONALS DRAWINGS MORTAR SHALL COMPLY WITH THE MINIMUM REQUIREMENTS OF ASTM C270 FOR TYPE AND SPECIFICATIONS, FOR ITEMS WHICH MAY ADVERSELY AFFECT THE STRUCTURE AND M OR S W/ (COMPRESSIVE STRENGTH=2500psi AND 1800psi RESPECTIVELY. SITE NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES AND/OR OMISSIONS. TESTED MORTAR CUBES SHALL ACHIEVE A MINIMUM OF 80% OF THE DESIGN 0 ' SUBMITTAL SETS SHALL CONSIST OF A MAXIMUM OF 1 SEPIA AND 2 BLUE LINES, COMPRESSIVE STRENGTH) ADDITIONAL BLUE LINES WILL BE DISCARDED. BLOCK SHALL NOT BE MOISTENED BEFORE GROUTING. SUBMITTALS TO ENGINEER OF RECORD FOR REVIEW MUST CONTAIN THE GENERAL � cn z z ALL CROSS WEBS SHALL BE FULLY BEDDED IN MORTAR AROUND CELLS TO BE GROUTED. SEE SCHED FOR ,_j a o o » " CONTRACTOR'S STAMP SIGNIFYING HIS REVIEW/ACCEPTANCE. SUBMITTALS SENT WITHOUT STIRRUP SPCG a 3/8 x1 VERT (DUMMY) JOINT THE GS'S REVIEW STAMP WILL BE RETURNED AT HIS EXPENSE AND WITHOUT REVIEW. EACH SIDE OF TIE BEAM GROUT FOR FILLED CELLS SHALL BE PLACED AS INDICATED BELOW- ALL SECTIONS AND DETAILS SHALL BE CONSIDERED TO BE TYPICAL OR SIMILAR UNLESS NOTES: SEE PLANS AND PLAN NOTES FOR ``•'� ''` `� f ANOTHER SECTION OR DETAIL IS REFERENCED ON THE PLANS. 1. DO NOT GROUT UNTIL MORTAR HAS SET8" JOINT LOCATION OF GROUTED CELLS - IL-3 SUFFICIENTLY TO WITHSTAND THE STOP GROUT MIN 1 1/2" BELOW /L PRESSURE OF THE GROUT. WAIT NOT TOP OF UNIT IF GROUTING IS ADJUST STIRRUP REINF CONT 0 FOUNDATIONS LESS THAN 24 HOURS. STOPPED FOR MORE THAN ONE LOCATION SLIGHTLY CONTROL JOINT IN HOUR. TO CLEAR THE CONIC TIE BEAM CONFORMANCE WITH THE REQUIREMENTS OUTLINED IN THE GEOTECHNICAL SOILS REPORT 2. WAIT A MINIMUM OF (1) HOUR BEFOREJOINT BY 2" (MIN) SHALL BE DETERMINED BY PERFORMING INDUSTRY STANDARD SOIL DENSITY TESTS BY A PLACING NEW GROUT ON A PREVIOUS . r MAX HEIGHT OF LIFT = 5' -Om. CERTIFIED TESTING AGENCY. LIFT WAIT 3 TO 5 MINUTES AND M C J @ TIE BEAM CONSOLIDATE WITH FLEXIBLE CONDITIONS DISCOVERED BY THE GENERAL CONTRACTOR AND/OR GEOTECHNICAL FIELD ' = CABLE VIBRATOR. JOB SITE MIXING OF GROUT SHALL NOT BE PERMITTED. TESTING SHALL CONFORM TO REPRESENTATIVE DURING EXCAVATION WHICH MAY PREVENT THE ATTAINMENT OF THE 3. THE MINIMUM CONTINUOUS , , RECONSOLIDATE AFTER AN ASTM C1019. SEE TEST MOLD DETAIL BELOW. SEE SCHEDULE UNDER CONCRETE NOTES UNOBSTRUCTED CLEAR AREA IN CELL TO • ' FOR COMPRESSIVE STRENGTH AND SLUMP REQUIREMENTS. ALLOWABLE BEARING PRESSURE STATED IN THE GEOTECHNICAL SOILS REPORT, SHALL BE ADDITIONAL 30 MINUTES BEFORE '!' REPORTED TO THE ARCHITECT/ENGINEER. RECEIVE GROUT MUST BE NOT LESS " PLASTICITY IS LOST. GROUT -TEST PRISM THAN 3x3. SEE CONCRETE GENERAL NOTES NOTE: FOUNDATION DESIGN VALUES - 2,000PSFASSUMED FOR GROUT PROPERTIES (4) 8x8x16 CMU ( ) 4. MORTAR FINS MUST BE REMOVED AS BLOCKS REQUIRED BLOCK PLACEMENT PROCEEDS. IF WALL IS LAID UP NO GREATER REINFORCING: 5. MORTAR DROPPINGS MUST BE KEPT OUT THAN 5'-0" IN HEIGHT ABOVE THE COVER UNITS USING ` ALL REINFORCING SHALL BE DOMESTICALLY PRODUCED WITH REBAR CONFORMING TO OF CELLS WHICH ARE TO BE GROUTED. FOOTING OR PREVIOUS GROUT ABSORPTIVE PAPER ASTM -615 FOR GRADE 60 STEEL, AND WELDED WIRE FABRIC (WWF) TO ASTM A-185. LIFT(S), A CLEAN-OUT HOLE SHALL TOWELLING W/ TAPE 6• MAXIMUM WALL HEIGHT FROM TOP OF NOT BE REQUIRED. OTHERWISE, SPLICES AND ANCHORAGE OF REINFORCING SHALL BE AS FOLLOWS UNLESS OTHERWISE FOOTING OR PREVIOUS GROUT POURS PROVIDE CLEAN- OUT HOLE WI, 3"x3"x1 5/8" WOOD BLOCK FRONT BLOCK REMOVED WiRb WIRE FABRIC 12" MIN. LAID UP AT ONE TIME SHALL BE 12'-0". MINIMUM SIZE OF 3"x3". FOR CLARITY POURED CONCRETE 36 X BAR DIA (12" MIN) OVERHANGING MORTAR AND DEBRIS GROUTED CELLS 48 X BAR DIA SHALL BE REMOVED FROM INSIDE DETAIL MASONRY GROUT GROUTING DETAIL THE CELL WALLS. SEAL PRIOR TO TEST MOLD ASTM C -1019 REINFORCEMENT IN WALLS, FOOTINGS AND BEAMS SHALL BE GROUTING BUT AFTER INSPECTION. CONTINUOUS AND LAPPED AS SPECIFIED ABOVE, UNLESS GROUT PLACEMENT STOPPED FOR (1) HOUR OR MORE SHOULD BE NOTED OTHERWISE. HOOK AND LAP ALL CORNER AND STOPPED (1 1/2") BELOW THE TOP OF THE MASONRY UNIT TO PROVIDE INTERSECTING BARS. (SEE REINF DEVELOPMENT DTL BLW).A KEY FOR SUBSEQUENT GROUTING. MASONRY CONT �P co STOPPING AND RESUMING WORK: RACK BACK 1/2 -UNIT LENGTH IN EACH TYPICAL MECHANICAL OPENING DETAIL: � COURSE. DO NOT TOOTH. CLEAN EXPOSED SURFACES OF SET MASONRY WET UNITS LIGHTLY (IF REQ'D) AND REMOVE LOOSE MAS GC TO O�CONTACT ENGINEER IF OPENING EXCEEDS SIZE AND AND SPACING SHOWN. UNITS AND MORTAR PRIOR TO LAYING FRESH MASONRY. CONCRETE FILLED DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS. REINF THADD TYP WALL PC "U" LINTEL W/ ADD TYP WALL 48 REINF THIS BAR DIA LOCA110NIS (2) #5 & 8" BRIG �LOCAT r%kl DO NOT APPLY CONCENTRATED LOADS TO MASONRY WALLS FOR (7) DAYS. 0 EACH END MAXIMUM CONTROL JOINT SPACING FOR CONCRETE MASONRY UNITS SHALL BE THREE (3) X WALL HEIGHT BUT NO FURTHER THAN 50FT. REFERENCE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS. :t .K' .';• BACKER ROD AND FILLED CELL EA SIDE OF '+ RESILIENT CAULIQNG�? MCJ W/ TYP WALL REINF. � `.' '•; . • . ,., • ' SCHEDUL REINE •'.•. •. •• , MATCH FTG L1/2" REINF xT/ FTG EL EE NEOPRENE PRE- FORMED GASKET THRU-WALL VERTICAL NOTES: CONTROL JOINT 1. THRU-WALL JOINT SHALL BE CONTINUOUS WITHOUT INTERRUP11ON FROM i MI MATInN Tn TnP nF WAI I L_ t �-- CORNERREINF DEVELOPMENT DETAIL 2. TERMINATE TYPICAL HORIZONTAL JOINT REINFORCING AT JOINT. L COVER FOR REINFORCING SHALL BE AS FOLLOWS: 3. MAXIMUM SPACING OF CONTROL JOINTS SHALL BE (3 x WALL HEIGHT) OR 50'-0", WHICHEVER IS LESS. 1. a. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" MASONRY CONTROL J T (M C J MIN 3'-4" p MAX S-4" MIN 3'-4" b. CONCRETE EXPOSED TO EARTH OR WEATHER: BETWEEN OPNGS BETWEEN OPNGS #6 THRU #18 BARS 2" FILL CORE SOLID W/ RESIL CAULKING TYP M E C H 0 P N G TH R U FTG #5 BAR, W31 OR D31 WIRE AND SMALLER 1 1/2" MORTAR FOR FULL HT 15# BUILDING FELT c. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: BON BREAKER TEMPORARY BRACING AND SHORING OF WALLS TO PROVIDE STABILITY SLABS, WALLS, JOISTS:, s ;�f DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. 1 1 #14 AND #18 BARS /2" '�'' 'r •`�'�• #11 BAR AND SMALLER 1 1/ PROVIDE GROUT FILLED PRECAST U -LINTELS WITH (1) #5 CONT AT ALL OPENINGS WHERE t -CONTROL JOINT CONCRETE BEAMS ARE NOT SHOWN OR NOTED. MINIMUM UNFILLED LINTEL CAPACITY = THE CONTRACTOR MAY USE CONTROL TYPE BLOCK W/ ARCH APPROVAL 400 Ib/LF FOR SPAN INDICATED. MASONRY CONTROL JT (MCJ) ALTERNATE HORIZONTALLY REINFORCE WALLS WITH LADDER TYPE (ASTM A-82, #9 GAGE WIRE) DEFORMED REINFORCEMENT EQUAL TO DURO-WALL IN BED JOINTS AT 16 OC UNO, MEASURED VERTICALLY. PLACE PER MFR INSTRUCTIONS. LAP ALL HORIZONTAL JOINT REINFORCING 8" MIN. NOTES, I . DETAIL HAS BEEN DESIGNED TO MEET ALL ANTICIPATED LOADING CONDITIONS OUTLINED IN THE 2017 EDITION OF THE FLORIDA BUILDING CODE FOR A 140MPH, RISK CATEGORY II, EXF05UPE "C" WIND LOAD EVENT. 2. 5EE CIVIU51TE PLAN (BY OTHER5) FOR LOCATION OF DUMP5TER ENCLOSURE. 3. PROVIDE (2) FILLED CELLS AT D15CONTIN0005 END5 AND (3) FILLED CELLS AT INTERSECTING CORNER5 (TYP.). 4. SEE CIVIU51TE PLAN (BY OTHER5) FOR REQUIRED, WIDTH, AND LENGTH OF DUMP5TER ENCLOSURE. 0 I (2) #5 CONT IN KO BLK 0 T/ WALL - BRICK WHERE INDICATED, REF: ARCH DWGS ---,, NOTES 1. PLACE THRU-WALL CONTROL JOINTS AT 50'-0" OC MAX AND 20'-0" FROM CORNERS. DO NOT CONTINUE HORIZONTAL REINF ACRnCC (:nNTRni .InINTC CFF CELL W/ MATCH DRS 0 FDN. SEE SCH FOR SPACING •EJ 6" SLAB -ON -GRADE REINF. W/ 6x6 i- W2.1 xW2.1 WWF k4l iJ WN I. BOT BARS SCALE i S E C TI O N SEE SCH N.T.S. D-1(TYPICAL DUMPSTER ENCLOSURE WALL) CONCRETE: ALL CONCRETE SHALL HAVE THE FOLLOWING MIN. PROPERTIES: LOCATION S28 DAYMAX TRENGTH DUMPSTER WALL REINFORCING SCHEDULE FOUNDATION WALL H FOOTING SIZE (W X L) CMU WIDTH (NOMINAL) FOOTING REINFORCING 3,000 psi WALL REINFORCING UP TO 5'-4" 3'-0" x CONT 8 (3) #5 CONT T&B, #4 TIES 0 16" OC #5 0 48" OC 5'-5" TO 6'-8" 3'-0" x CONT 8 (3) #5 CONT T&B, #4 TIES 0 16" OC #5 0 48" OC 6'-9" TO 8'-0" S-8" x CONT 8 (3) #5 CONT T&B, #4 TIES 012' OC #5 0 32" OC 8'-1" TO 8'-8" 3'-8" x CONT 8 (3) #5 CONT T&B, #4 TIES 012" OC 15 0 24" OC 8'-9" TO 9'-4" 4'-4" x CONT 8 (4) #5 CONT T&B, 14 TIES 012- OC 15 0 16" OC 1-977TO 10'-0" 4'-4" x CONT 8 (4) #5 CONT T&B, #4 TIES 012' OC #6 0 16" OC 0 I (2) #5 CONT IN KO BLK 0 T/ WALL - BRICK WHERE INDICATED, REF: ARCH DWGS ---,, NOTES 1. PLACE THRU-WALL CONTROL JOINTS AT 50'-0" OC MAX AND 20'-0" FROM CORNERS. DO NOT CONTINUE HORIZONTAL REINF ACRnCC (:nNTRni .InINTC CFF CELL W/ MATCH DRS 0 FDN. SEE SCH FOR SPACING •EJ 6" SLAB -ON -GRADE REINF. W/ 6x6 i- W2.1 xW2.1 WWF k4l iJ WN I. BOT BARS SCALE i S E C TI O N SEE SCH N.T.S. D-1(TYPICAL DUMPSTER ENCLOSURE WALL) CONCRETE: ALL CONCRETE SHALL HAVE THE FOLLOWING MIN. PROPERTIES: LOCATION S28 DAYMAX TRENGTH SLUMP T AGGR. FOUNDATION 3,000 psi 4" ± 1" 1 1/2 - 2"SLAB-ON-GRADE SLAB -ON -GRADE UP TO 4" THICK 3,000 psi 4 ± 1" 11/2- SLAB -ON -GRADE (OVER 4" THICK) 4,000 psi 4" f 1" 1 1 GROUT FOR FILLED CELLS 2,500 psi 8" f. 11" 3/8* SLAB THICKNESS IN -1 4 1 NATES: 6 17 18 1• SLUMP FOR RAMPS AND SLOPING SURFACES SHALL NOT EXCEED 4".�n 2. SEE MASONRY GENERAL NOTES FOR GROUT TESTING REQUIREMENTS. VERTICAL REINFORCING MUST HAVE A MINIMUM CLEARANCE OF 1/2" TO INSIDE FACE. CONCRETE PROPERTIES SHALL BE VERIFIED THROUGH INDUSTRY STANDARD TESTING VERTICAL BAR LAP = 48 x BAR DIAMETER. SEE FILLED CELL DETAIL BELOW FOR PROCEDURES BY A CERTIFIED TESTING AGENCY. MIN. TEST REQUIRED SHALL INCLUDE ADD111ONAL INFORMATION. SLUMP AND CYLINDER BEAKS FOR COMPRESSIVE STRENGTH. FINDINGS SHALL BE SUBMITTED 231 TO THE ARCH./ENG. FOR REVIEW. mYV 4m = NOTES: CONCRETE WORK SHALL CONFORM TO ACI 301 (LATEST EDITION) SPECIFICATIONS FOR 1• SEE FOUNDATION PLANS FOR ALL STRUCTURAL CONCRETE FOR BUILDINGS. VERT REINF. REQ. TYP VERTICAL STOP VERTS 2" FROM < ga REINFORCING SIZE &SPACING ' TOP OF WALL & CONCRETE MIX DESIGN SUBMITTALS SHALL MEET THE FOLLOWING CRITERIA: SHALL BE ABOVE AND BELOW ALL PROVIDE STANDARD ACI HOOK (TYP) 1. EACH MIX DESIGN SHALL BE LABELED TO INDICATE THE AREA IN WHICH THE COWRETE IS WALL OPENINGS. VERT BAR CENTERED IN TO BE PLACED. FAILURE TO DO SO WILL RESULT IN THE REJECTION OF SUBMITTALS. 2. EXTEND ALL VERTICAL WALL •` FILLED CELL 2. PROPOSED MIX DESIGN SHALL BE ACCORDANCE WITH ACI 301 METHOD 1 OR METHOD 2 . REINFORCEMENT TO WITHIN 2" DOWELS SAME AS VERT SUPPORTING DATA SHALL BE PROVIDED IN TABULAR FORM FOR EACH SEPARATE PROPOSED OF TOP OF WALL OR BEAM BARS MIX. UNLESS NOTED OTHERWISE. TERMINATE REINFORCING WITH ' - HORIZ JOINT REINF 0 3. ENTRAPPED AIR CONTENT SHALL NOT EXCEED 37. 2 PERM, IT # STANDARD ACI 90 DEGREE w v ? 16" OC VERT SPACING M r �• 4. ADMIXTURES USED TO ENTRAIN AIR ARE NOT ACCEPTABLE. HOOK IF ROOF JOISTS AND/OR Q 0 0ON TRUSSES BEAR ON TOP OF i o '' STANDARD HOOK SITE ADDED WATER IS NOT ACCEPTABLE. ADDING WATER TO THE MIX WILL RESULT IN WALL AND THERE IS NO a Q ;� (ALTERNATE SIDES) REJECTION OF THE RESULTS BY THE ENGINEER OF RECORD. PARAPET. IF PARAPET EXISTS, J m HOOK IS NOT REQUIRED. SLAB ON GRADE FILLED CELL DETAIL t �' „ •. •' UNLESS SPECIFICALLY STATED OTHERWISE IN THE GEOTECHNICAL SOILS REPORT, THE FOLLOWING MINIMUM CRITERIA SHALL BE ADHERED T0. a.) INTERIOR FILL SHALL BE COMPACTED TO A MINIMUM OF 95% OF THE MODIFIED PROCTOR VERTICAL REINFORCEMENT IN WALLS SHALL BE SECURED AND LATERALLY SUPPORTED MAXIMUM DRY DENSITY TEST (ASTM D1557). AGAINST DISPLACEMENT AT INTERVALS NOT EXCEEDING 192 x BAR DIAMETER OR 10 FT b.) COMPACTION OF THE SOIL IN THE FIELD SHALL BE MONITORED/CONTROLLED BY A WHICHEVER IS LESS WHENEVER A CLEANOUT IS REQUIRED. SEE GROUTING DETAIL NOTE REPRESENTATIVE OF A QUALIFIED LABORATORY. FOR CLEANOUT REQUIREMENTS. c.) EACH LAYER OF FILL SHALL NOT EXCEED 12" THICK AND SHALL BE COMPACTED PRIOR TO REINFORCE MASONRY OPENINGS GREATER THAN 1'-0" WIDE, WITH HORIZ JT REINF PLACED PLACEMENT OF THE NEXT LAYER. IN (2) HORIZ JOINT'S APPROXIMATELY 8" APART, IMMEDIATELY ABOVE THE LINTEL AND MAXIMUM SPACING OF CONTROL JOINTS SHALL BE AS SHOWN IN THE TABLE BELOW. IMMEDIATELY BELOW THE SILL EXTEND REINFORCING A MINIMUM OF 2'-0" BEYOND PATTERNS SHALL BE APPROXIMATELY SQUARE W/ RATIO OF LONG SIDE TO SHORT SIDE JAMBS OF THE OPENING EXCEPT AT CONTROL JOINTS. SEE PLAN FOR ADDITIONAL NOT TO EXCEED 1.5 TO 1.0. REQUIREMENTS. SLAB THICKNESS IN -1 4 1 5 1 6 17 18 19110 SPACING (FT) 1121131151181201 V / W np�pm3'130 231 25 MIX DESIGNS CONTAINING AGGREGATE LESS THAN 3/4" ARE NOT ACCEPTABLE CUT SLAB AS SOON AS AGGREGATE DOES NOT DISLODGE (MUST BE WITHIN THE SAME DAY AS THE CONC. WAS PLACED) CARE SHALL BE TAKEN BY THE GENERAL CONTRACTOR WHEN DETERMINING THE LOCATION OF SJ'S AND CJ'S TO ENSURE SLAB JOINTS DOES NOT READ THROUGH THE ARCHITECTURAL FINISHES. WAREHOUSE SLABS SHALL BE POWER -TROWELLED TO A HARD, SMOOTH BURNISHED FINISH. THE FINAL TROWEL PASS SHALL BE DONE BY MACHINE - NOT BY HAND. WITHIN 30 MINUTES OF THE FINAL TROWEL PASS, THE FLOOR SHALL BE CURED WITH EUCLID'S SUPER REZ-SEAL OR APPROVED EQUAL SLAB THICKNESS SHALL BE INCREASED AS REQUIRED TO PROVIDE ADEQUATE SUPPORT FOR CRANE LOADS WITHOUT CRACKING SLAB. MARKUPS k DATE BY 155UE 1 05-07-18 J5V PER MARKUI'5. 2 05-24-18 J5V PER MARKUPS. P,EV1510N5 DUMPSTER ENCLOSURE RINEHART 55 A550CIATE5 LLC 145 1 RINEHART ROAD, 5ANFORD, FL 32771 rL a� r Z �< �N Li0 -1 i s -j V / W np�pm3'130 WLpz� U mYV 4m = N Wg=wtj� t�2Y' ° R C < ga ";-M 90 U) <w U y�l'U'O"iRE z �-EtF08" r ��uo9oo�QN °�N nnC 5u. N Z V I. 0ON Iwo �Q sg u Lu No. 554 ST a o ICs+ rN /ON A t. EN�`���`� DRAWN BY DATE EDJ 02-09-18 CHECKED BY DATE RMB 05-10-18 SCALE N.T.5. JOB NUMBER 2035 FILE NAME 2035-5TR.DWG SHEET D -i I -i -i -n -i i. SITE PLAN (FOR REFERENCE ONLY) DUMPSTER ENCLOSURE RINEHART SS ASSOCIATES LLC 1451 RINEHART ROAD; SANFORD, FL 32771 •I • 0 ............. S 'rte ' • �• •.. � _ .','••• : •• ; • :.. :.,. .;. � : ! •• .... I =0000i� ooaaaa� THE GENERAL CONTRACTOR SHALL REVIEW AND DETERMINE THAT ALL DIMENSIONS ARE 28 DAY STRENGTH COORDINATED BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO MASONRY CONSTRUCTION, MATERIALS, AND INSPECTION SHALL C COMMENCING WITH THE FABRICATION OF MATERIALS OR THE START OF CONSTRUCTION. MINIMUM REQUIREMENTS OF THE LATEST ADOPTED EDITIONS ACI 530 & 530.1, ASCE THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT THE 5 & 6, TMS 402 & 602, ASTM C476 & C1019, AND NCMA TEK 107, UNLESS SPECIFIED IN THESE CONTRACT DOCUMENTS. STRUCTURE, THE WORK PERSONS, AND OTHER PEOPLE DURING CONSTRUCTION. HE SHALL 1. THRU-WALL JOINT SHALL BE CONTINUOUS WITHOUT INTERRUPTION FROM FOUNDATION TO TOP OF WALL L 2 2. TERMINATE TYPICAL HORIZONTAL JOINT REINFORCING AT JOINT. 3. MAXIMUM SPACING OF CONTROL JOINTS SHALL BE (3 x WALL HEIGHT) OR SUPERVISE AND DIRECT THE WORK AND BE RESPONSIBLE FOR ALL CONSTRUCTION. CONCRETE BLOCKS SHALL CONFORM TO THE MINIMUM REQ. OF ASTM C-90 WITH NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE REDUCED IN STRENGTH. f m=1,500psi (1,900psi ON THE NET AREA) THE GENERAL CONTRACTOR SHALL COORDINATE ALL DESIGN PROFESSIONALS DRAWINGS MORTAR SHALL COMPLY WITH THE MINIMUM REQUIREMENTS OF ASTM C270 FOR TYPE AND SPECIFICATIONS, FOR ITEMS WHICH MAY ADVERSELY AFFECT THE STRUCTURE AND M OR S W/ (COMPRESSIVE STRENGTH=2500psi AND 1800psi RESPECTIVELY. SITE NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES AND/OR OMISSIONS. TESTED MORTAR CUBES SHALL ACHIEVE A MINIMUM OF 80% OF THE DESIGN S-0" x CONT COMPRESSIVE STRENGTH) SUBMITTAL SETS SHALL CONSIST OF A MAXIMUM OF 1 SEPIA AND 2 BLUE LINES, OC ADDITIONAL BLUE LINES WILL BE DISCARDED. BLOCK SHALL NOT BE MOISTENED BEFORE GROUTING. SUBMITTALS TO ENGINEER OF RECORD FOR REVIEW MUST CONTAIN THE GENERAL TO 8'-0" CONTRACTOR'S STAMP SIGNIFYING HIS REVIEW/ACCEPTANCE. SUBMITTALS SENT WITHOUT ALL CROSS WEBS SHALL BE FULLY BEDDED IN MORTAR AROUND CELLS TO BE GROUTED. THE GS'S REVIEW STAMP WILL BE RETURNED AT HIS EXPENSE AND WITHOUT REVIEW. OC #5 032" GROUT FOR FILLED CELLS SHALL BE PLACED AS INDICATED BELOW: ALL SECTIONS AND DETAILS SHALL BE CONSIDERED TO BE TYPICAL OR SIMILAR UNLESS NOTES: SEE PLANS AND PLAN NOTES FOR ANOTHER SECTION OR DETAIL IS REFERENCED ON THE PLANS. 1. DO NOT GROUT UNTIL MORTAR HAS SET LOCATION OF GROUTED CELLS (3) #5 CONT T&B, #4 TIES 0 12" SUFFICIENTLY TO WITHSTAND THE STOP GROUT MIN 1 1/2" BELOW OC PRESSURE OF THE GROUT. WAIT NOT TOP OF UNIT IF GROUTING IS FOUNDATIONS LESS THAN 24 HOURS. STOPPED FOR MORE THAN ONE OC #5 0 16" HOUR. CONFORMANCE WITH THE REQUIREMENTS OUTLINED IN THE GEOTECHNICAL SOILS REPORT 2• WAIT A MINIMUM OF (1) HOUR BEFORE 4'-4" x CONT SHALL BE DETERMINED BY PERFORMING INDUSTRY STANDARD SOIL DENSITY TESTS BY A PLACING NEW GROUT ON A PREVIOUS ' ' MAX HEIGHT OF LIFT = 5'-0". CERTIFIED TESTING AGENCY. OC WAIT 3 TO 5 MINUTES AND ' +' CONSOLIDATE WITH FLEXIBLE CONDITIONS DISCOVERED BY THE GENERAL CONTRACTOR AND/OR GEOTECHNICAL FIELD CABLE VIBRATOR. REPRESENTATIVE DURING EXCAVATION WHICH MAY PREVENT THE ATTAINMENT OF THE 3 THE MINIMUM CONTINUOUS RECONSOLIDATE AFTER AN ALLOWABLE BEARING PRESSURE STATED IN THE GEOTECHNICAL SOILS REPORT, SHALL BE UNOBSTRUCTED CLEAR AREA IN CELL TO ADDITIONAL 30 MINUTES BEFORE REPORTED TO THE ARCHITECT/ENGINEER. RECEIVE GROUT MUST BE NOT LESS PLASTICITY IS LOST. b.) COMPAC11ON OF THE SOIL IN THE FIELD SHALL BE MONITORED/CONTROLLED BY A THAN 3"x3". SEE CONCRETE GENERAL NOTES FOUNDATION DESIGN VALUES - 2,000PSF (ASSUMED) 4• MORTAR FINS MUST BE REMOVED AS FOR GROUT PROPERTIES REINFORCE MASONRY OPENINGS GREATER THAN V-0" WIDE, WITH HORIZ JT REINF PLACED BLOCK PLACEMENT PROCEEDS. IN (2) HORIZ JOINT'S APPROXIMATELY 8" APART, IMMEDIATELY ABOVE THE LINTEL AND REINFORCING: IF WALL IS LAID UP NO GREATER ALL REINFORCING SHALL BE DOMESTICALLY PRODUCED WITH REBAR CONFORMING TO 5. MORTAR DROPPINGS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE GROUTED. NOT TO EXCEED 1.5 TO 1.0. THAN 5'-0" IN HEIGHT ABOVE THE FOOTING OR PREVIOUS GROUT ASTM -615 FOR GRADE 60 STEEL, AND WELDED WIRE FABRIC (WWF) TO ASTM A-185. LIFT(S), A CLEAN-OUT HOLE SHALL SPLICES AND ANCHORAGE OF REINFORCING SHALL BE AS FOLLOWS UNLESS OTHERWISE 6• MAXIMUM WALL HEIGHT FROM TOP OF FOOTING OR PREVIOUS GROUT POURS NOT BE REQUIRED. OTHERWISE, PROVIDE CLEAN- OUT HOLE WITH WIRb WIRE FABRIC 12" MIN. LAID UP AT ONE TIME SHALL BE 12'-0". MINIMUM SIZE OF 3"x3". POURED CONCRETE 36 X BAR DIA (12" MIN) OVERHANGING MORTAR AND DEBRIS GROUTED CELLS 48 X BAR DIA GROUTING DETAIL SHALL BE REMOVED THE CELL WALLS. SEAL PRIOR INSIDE REINFORCEMENT IN WALLS, FOOTINGS AND BEAMS SHALL BE GROUTING BUT AFTER INSPECTION. GROUT PLACEMENT STOPPED FOR (1) HOUR OR MORE SHOULD BE CONTINUOUS AND LAPPED AS SPECIFIED ABOVE, UNLESS NOTED OTHERWISE. HOOK AND LAP ALL CORNER AND STOPPED (1 1/2") BELOW THE TOP OF THE MASONRY UNIT TO PROVIDE INTERSECTING BARS. (SEE REINF DEVELOPMENT RTL BLW). �P' A KEY FOR SUBSEQUENT GROUTING. CONFORM TO THE Q�Q Co STOPPING AND RESUMING WORK: RACK BACK 1/2 -UNIT LENGTH IN EACH O COURSE. DO NOT TOOTH. CLEAN EXPOSED SURFACES OF SET MASONRY WET UNITS LIGHTLY (IF REQ'D) AND REMOVE LOOSE MAS UNITS AND MORTAR PRIOR TO LAYING FRESH MASONRY. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS. 48 BAR DIA. DO NOT APPLY CONCENTRATED LOADS TO MASONRY WALLS FOR (7) DAYS. OR I' -G" MIN. MAXIMUM CONTROL JOINT SPACING FOR CONCRETE MASONRY UNITS SHALL BE THREE (3) X WALL HEIGHT BUT NO FURTHER THAN 50FT. REFERENCE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS. BACKER ROD AND EA SIE 0 RESILIENT CAULKING MCJ W/ TYP WALL REINF. ,,. , -� , •. I / INTERSECTION coRNER REINF DEVELOPMENT DETAIL COVER FOR REINFORCING SHALL BE AS FOLLOWS: 1. a. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH b. CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THRU 118 BARS #5 BAR, W31 OR D31 WIRE AND SMALLER c. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS: #14 AND #18 BARS #11 BAR AND SMALLER �m1� • � J SEE SCHED FOR " STIRRUP SPCG ¢ 3/8"x1" VERT (DUMMY) JOINT EACH SIDE OF TIE BEAM x-3/8" JOINT ADJUST STIRRUP REINF CONT LOCATION SLIGHTLY CONTROL JOINT IN TO CLEAR THE CONC TIE BEAM JOINT BY 2" (MIN) MCJ @ TIE BEAM JOB SITE MIXING OF GROUT SHALL NOT BE PERMITTED. TESTING SHALL CONFORM TO ASTM C1019. SEE TEST MOLD DETAIL BELOW. SEE SCHEDULE UNDER CONCRETE NOTES FOR COMPRESSIVE STRENGTH AND SLUMP REQUIREMENTS. NOTE: GROUT TEST PRISM (4) 8x8x16 CMU BLOCKS REQUIRED COVER UNITS USING ABSORPTIVE PAPER TOWELLING W/ TAPE 3"x3"x1 5/8" WOOD BLOCK FRONT BLOCK REMOVED FOR CLARITY DETAIL MASONRY GROUT TEST MOLD C-1019) MASONRY CONT TYPICAL MECHANICAL OPENING DETAIL- NOTE: E TAIL: NOTE: GC TO CONTACT ENGINEER IF OPENING EXCEEDS SIZE AND AND SPACING SHOWN. VCONCRETE FILLED ADD TYP WALL " "/-LOCATION ADD TYP WALL PC U LINTEL W/ REINF THIS (2) #5 & 8" BRGREINF THIS LOCATION 0 EACH END SCHEDUL Dle. :. •.r•:� •fir. .•'- + - - - MATCH FTG 28 DAY STRENGTH DUMPSTER WALL NEOPRENE PRE- FORMED GASKET THRU-WALL VERTICAL REINF Ll/2" '� N FTG EL EE T/ 1 PLAN NOTES: CONTROL JOINT - - -- - FOOTING REINFORCING 1. THRU-WALL JOINT SHALL BE CONTINUOUS WITHOUT INTERRUPTION FROM FOUNDATION TO TOP OF WALL L 2 2. TERMINATE TYPICAL HORIZONTAL JOINT REINFORCING AT JOINT. 3. MAXIMUM SPACING OF CONTROL JOINTS SHALL BE (3 x WALL HEIGHT) OR J 2 UP TO 5'-4" S-0" x CONT 8 L o OC 50'-0", WHICHEVER IS LESS. OC ' 3" MASONRY CONTROL J T (MCJ) MIN S-4" MAX S-4"1. MIN S -4 - BETWEEN OPNGS BETWEEN OPNGS " 1/2» FILL CORE SOLID W/ RESIL CAULKING TYP M E C H 0 P N G TH R U FTG MORTAR FOR FULL HT 15# BUILDING FELT BON BREAKER TEMPORARY BRACING AND SHORING OF WALLS TO PROVIDE STABILITY DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. 1 1/2- 3/4- /2 :. .;- 3/4" PROVIDE GROUT FILLED PRECAST U -LINTELS WITH (1) #5 CONT AT ALL OPENINGS WHERE I�--CONTROL JOINT CONCRETE BEAMS ARE NOT SHOWN OR NOTED. MINIMUM UNFILLED LINTEL CAPACITY = THE CONTRACTOR MAY USE CONTROL TYPE BLOCK W/ ARCH APPROVAL 400 Ib/LF FOR SPAN INDICATED. MASONRY CONTROL J T (MCJ) ALTERNATE• HORIZONTALLY REINFORCE WALLS WITH LADDER TYPE (ASTM A-82, #9 GAGE WIRE) DEFORMED REINFORCEMENT EQUAL TO DURO-WALL IN BED JOINTS AT 16" OC UNO, MEASURED VERTICALLY. PLACE PER MFR INSTRUCTIONS. LAP ALL HORIZONTAL JOINT REINFORCING 8" MIN. 1 NOTES; I . DETAIL HAS BEEN DE51GNED TO MEET ALL ANTICIPATED LOADING CONDITIONS OUTLINED IN THE 2017 EDITION OF TH;E FLORIDA BUILDING CODE FOR A 140MPH, R15K CATEGORY II, EXPOSURE "C" WIND LOAD EVENT. 2. • 5EE CIVIU51TE PLAN (5Y OTHERS) FOR LOCATION OF DUMPSTER ENCLOSURE. 3. PROVIDE (2) FILLED CELL5 AT D15CONTIN0005 ENDS AND (3) FILLED CELLS AT INTER5ECTING CORNERS (TYP.). 4. 5EE CIVIU51TE PLAN (BY OTHER5) FOR REQUIRED, WIDTH, AND LENGTH OF DUMPSTER ENCLOSURE. (2) #5 CONT IN KO BLK 0 T/ WALL - .. BRICK INDICATED, RER ="MO� ARCH DWGS NOTES: 1. PLACE THRU-WALL CONTROL JOINTS AT 50'-0" OC MAX AND 20'-0" FROM CORNERS. DO NOT CONTINUE HORIZONTAL REINF ACROSS CONTROL JOINTS. SEE MASONRY CONTROL JOINT DETAIL VERT BAR 1N GROUT FILLED CELL W/ MATCH DWLS 0 FDN. SEE SCH FOR SPACING U uj EJ 6" SLAB -ON -GRADE uj SLAB rn REINF. W/ 6x6 OR W2.1 xW2.1 WWF GRADE T/SLAB MAX \/\.\\�� �,z DNIKM 1 EL SEE \\ • \�' REINF, SEE PLAN 12" FDN SCH (2) #5 CONT. BOT BARS EQ JSEE EQ scn� SECTIO N N.T.S. SEE SCH N.r(TYPICAL DUMPSTER ENCLOSURE WALL) CONCRETE: ALL CONCRETE SHALL HAVE THE FOLLOWING MIN. PROPERTIES: LOCATION NOTES: 28 DAY STRENGTH DUMPSTER WALL REINFORCING 5CHEDULE FOUNDATION WALL H FOOTING SIZE (W X L) CMU WIDTH (NOMINAL) FOOTING REINFORCING 3,000 psi WALL REINFORCING UP TO 5'-4" S-0" x CONT 8 (3) #5 CONT T&B, #4 TIES 0 16" OC #5 0 48" OC 5'-5" TO 6'-8" S-0" x CONT 8 (3) 15 CONT T&B, 14 TIES 0 16" OC #5 0 48" OC 6'-9" TO 8'-0" 3'-8" x CONT 8 (3) #5 CONT T&B, #4 TIES 012" OC #5 032" OC 8'-1" TO 8'-8" S-8" x CONT 8 (3) #5 CONT T&B, #4 TIES 0 12" OC #5 0 24" OC 8'-9" TO 9'-4" 4'-4" x CONT 8 (4) #5 CONT T&B, #4 TIES 012" OC #5 0 16" OC 9'-5" TO 10'-0" 4'-4" x CONT 8 (4) #5 CONT T&B, #4 TIES 0 12" OC #6 0 16" OC (2) #5 CONT IN KO BLK 0 T/ WALL - .. BRICK INDICATED, RER ="MO� ARCH DWGS NOTES: 1. PLACE THRU-WALL CONTROL JOINTS AT 50'-0" OC MAX AND 20'-0" FROM CORNERS. DO NOT CONTINUE HORIZONTAL REINF ACROSS CONTROL JOINTS. SEE MASONRY CONTROL JOINT DETAIL VERT BAR 1N GROUT FILLED CELL W/ MATCH DWLS 0 FDN. SEE SCH FOR SPACING U uj EJ 6" SLAB -ON -GRADE uj SLAB rn REINF. W/ 6x6 OR W2.1 xW2.1 WWF GRADE T/SLAB MAX \/\.\\�� �,z DNIKM 1 EL SEE \\ • \�' REINF, SEE PLAN 12" FDN SCH (2) #5 CONT. BOT BARS EQ JSEE EQ scn� SECTIO N N.T.S. SEE SCH N.r(TYPICAL DUMPSTER ENCLOSURE WALL) CONCRETE: ALL CONCRETE SHALL HAVE THE FOLLOWING MIN. PROPERTIES: LOCATION NOTES: 28 DAY STRENGTH SLUMP MAX GGR. FOUNDATION 3,000 psi 4" ± 1" 1 1 L2" SLAB -ON -GRADE UP TO 4" THICK 3,000 psi 4m ± 1 1 1/2" SLAB -ON -GRADE (OVER 4" THICK) 4,000 psi I 4" ± 1 1 1/2u GROUT FOR FILLED CELLS 2,500 si 8" ± 11" 3/8 - 8" SLAB THICKNESS IN - 1 4 NOTES: 6 17 1 • SLUMP FOR RAMPS AND SLOPING SURFACES SHALL NOT EXCEED 4". w 2. SEE MASONRY GENERAL NOTES FOR GROUT TESTING REQUIREMENTS. VERTICAL REINFORCING MUST HAVE A MINIMUM CLEARANCE OF 1/2" TO INSIDE FACE. CONCRETE PROPERTIES SHALL BE VERIFIED THROUGH INDUSTRY STANDARD TESTING VERTICAL BAR LAP = 48 x BAR DIAMETER. SEE FILLED CELL DETAIL BELOW FOR PROCEDURES BY A CERTIFIED TESTING AGENCY. MIN. TEST REQUIRED SHALL INCLUDE ADDITIONAL INFORMATION. SLUMP AND CYLINDER BEAKS FOR COMPRESSIVE STRENGTH. FINDINGS SHALL BE SUBMITTED 23 TO THE ARCH./ENG. FOR REVIEW. ;SOD .u -I 87 i NOTES: =L CONCRETE WORK SHALL CONFORM TO ACI 301 (LATEST EDITION) SPECIFICATIONS FOR 1 • SEE FOUNDATION PLANS FOR ALLSTRUCTURAL CONCRETE FOR BUILDINGS. VERT REINF. REQ. TYP VERTICAL STOP VERTS 2" FROM co?�py� REINFORCING SIZE & SPACING ' TOP OF WALL & CONCRETE MIX DESIGN SUBMITTALS SHALL MEET THE FOLLOWING CRITERIA: SHALL BE ABOVE AND BELOW ALL PROVIDE STANDARD ACI WALL OPENINGS. HOOK (TYP) 1. EACH MIX DESIGN SHALL BE LABELED TO INDICATE THE AREA IN WHICH THE CONCRETE IS VERT BAR CENTERED IN TO BE PLACED. FAILURE TO DO SO WILL RESULT IN THE REJEC11ON OF SUBMITTALS. 2. EXTEND ALL VERTICAL WALL •`•:� FILLED CELL 2. PROPOSED MIX DESIGN SHALL BE ACCORDANCE WITH ACI 301 METHOD 1 OR METHOD 2 . REINFORCEMENT TO WITHIN 2" DOWELS SAME AS VERT SUPPORTING DATA SHALL BE PROVIDED IN TABULAR FORM FOR EACH SEPARATE PROPOSED OF TOP OF WALL OR BEAM BARS MIX. UNLESS NOTED OTHERWISE. TERMINATE REINFORCING WITH HORIZ JOINT REINF ENTRAPPED AIR CONTENT SHALL NOT EXCEED 37. STANDARD ACI 90 DEGREE z3. v 16" OC VERT SPACING E HOOK IF ROOF JOISTS AND/OR w a ;. 4. ADMIXTURES USED TO ENTRAIN AIR ARE NOT ACCEPTABLE. TRUSSES BEAR ON TOP OF cn WALL AND THERE IS NOg O„ o STANDARD HOOK ,� (ALTERNATE SIDES) SITE ADDED WATER IS NOT ACCEPTABLE. ADDING WATER TO THE MIX WILL RESULT IN PARAPET. IF PARAPET EXISTS, m REJECTION OF THE RESULTS BY THE ENGINEER OF RECORD. HOOK IS NOT REQUIRED. ..: `�:,,':,t ,.�;:; �. -•L.: SLAB ON GRADE FILLED CELL DETAIL ' ' • � ~ � •" "" �'�'` UNLESS SPECIFICALLY STATED OTHERWISE IN THE GEOTECHNICAL SOILS REPORT, THE � :- •-�� �''•` FOLLOWING MINIMUM CRITERIA SHALL BE ADHERED T0. a.) INTERIOR FILL SHALL BE COMPACTED TO A MINIMUM OF 95% OF THE MODIFIED PROCTOR VERTICAL REINFORCEMENT IN WALLS SHALL BE SECURED AND LATERALLY SUPPORTED MAXIMUM DRY DENSITY TEST (ASTM D1557). AGAINST DISPLACEMENT AT INTERVALS NOT EXCEEDING 192 x BAR DIAMETER OR 10 FT WHICHEVER IS LESS WHENEVER A CLEANOUT IS REQUIRED. SEE GROUTING DETAIL NOTE b.) COMPAC11ON OF THE SOIL IN THE FIELD SHALL BE MONITORED/CONTROLLED BY A FOR CLEANOUT REQUIREMENTS. REPRESENTATIVE OF A QUALIFIED LABORATORY. c.) EACH LAYER OF FILL SHALL NOT EXCEED 12" THICK AND SHALL BE COMPACTED PRIOR TO REINFORCE MASONRY OPENINGS GREATER THAN V-0" WIDE, WITH HORIZ JT REINF PLACED PLACEMENT OF THE NEXT LAYER. IN (2) HORIZ JOINT'S APPROXIMATELY 8" APART, IMMEDIATELY ABOVE THE LINTEL AND MAXIMUM SPACING OF CONTROL JOINTS SHALL BE AS SHOWN IN THE TABLE BELOW. IMMEDIATELY BELOW THE SILL EXTEND REINFORCING A MINIMUM OF 2'-0" BEYOND PATTERNS SHALL BE APPROXIMATELY SQUARE W/ RATIO OF LONG SIDE TO SHORT SIDE JAMBS OF THE OPENING EXCEPT AT CONTROL JOINTS. SEE PLAN FOR ADDITIONAL NOT TO EXCEED 1.5 TO 1.0. REQUIREMENTS. SLAB THICKNESS IN - 1 4 1 5 1 6 17 18 19 w 10 SPACING (FT) 121131151181201 w U Fl} 23 2 MIX DESIGNS CONTAINING AGGREGATE LESS THAN 3/4" ARE NOT ACCEPTABLE CUT SLAB AS SOON AS AGGREGATE DOES NOT DISLODGE (MUST BE WITHIN THE SAME DAY AS THE CONC. WAS PLACED) CARE SHALL BE TAKEN BY THE GENERAL CONTRACTOR WHEN DETERMINING THE LOCATION OF SJ'S AND CJ'S TO ENSURE SLAB JOINTS DOES NOT READ THROUGH THE ARCHITECTURAL FINISHES. WAREHOUSE SLABS SHALL BE POWER -TROWELLED TO A HARD, SMOOTH BURNISHED FINISH. THE FINAL TROWEL PASS SHALL BE DONE BY MACHINE - NOT BY HAND. WITHIN 30 MINUTES OF THE FINAL TROWEL PASS, THE FLOOR SHALL BE CURED WITH EUCLID'S SUPER REZ-SEAL OR APPROVED* EQUAL SLAB THICKNESS SHALL BE INCREASED 'AS REQUIRED TO PROVIDE ADEQUATE SUPPORT FOR CRANE LOADS WITHOUT CRACKING SLAB. MARKUP5 k DACE BY 155Uf" I 05.07-18 J5V PER MARKUP5., 2 05-24-18 J5V PER MARKUP5. REVISIONS DUMPSTER ENCL05URE RINEHART 55 A550CIATE5 LLC 145 1 RINEHART ROAD, SANFORD, FL 32771 O a �Z Z� a� L � �Z 0 Lj CIO Fj-� L (t) w z E � -J w LL 5 Z CQ � o � Um �U w 0-/o < N Q z� > o� O� Z-0 o `0 .. BFB ,x �p \,\GENS� , No. 55 .fl' AT OF �O' F' •. \ ss�O N'A L' DRAWN BY I DATE EDJ 02-09-18 CHECKED BY DATE RMB 05-10-18 N.T.S. JOB NUMBER 2035 FILE NAME 2035-6TR. DWG SHEET D- f " I � s J w •�Na w U Fl} F L�z > ;SOD .u -I 87 i Nagy ii •� = z O s w LlJ a co?�py� �N�mr d, k4i �p (4'aaw g 0,jm 6-0 Wv1-7 �0[2 p� na p U �wy S., E w .. BFB ,x �p \,\GENS� , No. 55 .fl' AT OF �O' F' •. \ ss�O N'A L' DRAWN BY I DATE EDJ 02-09-18 CHECKED BY DATE RMB 05-10-18 N.T.S. JOB NUMBER 2035 FILE NAME 2035-6TR. DWG SHEET D- f " I DUMPSTER ENCLOSURE RINEHART SS ASSOCIATES LLC 1451 RWEt1ART ROAD; 5ANfORD, FL 32771 mi rri u w I I u I u I 6 6 V 9 19 19 S] I; I: a. . . . . . . . . CONFORM TO THE THE GENERAL CONTRACTOR SHALL REVIEW AND DETERMINE THAT ALL DIMENSIONS ARE 28 DAY STRENGTH COORDINATED BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO MASONRY CONSTRUCTION, MATERIALS, AND INSPECTION SHALL C COMMENCING WITH THE FABRICATION OF MATERIALS OR THE START OF CONSTRUCTION. MINIMUM REQUIREMENTS OF THE LATEST ADOPTED EDITIONS ACI 530 & 530.1, ASCE FOOTING SIZE (W X L) 5 & 6, TMS 402 & 602, ASTM C476 & C1019, AND NCMA TEK 107, UNLESS THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT THE SPECIFIED IN THESE CONTRACT DOCUMENTS. STRUCTURE, THE WORK PERSONS, AND OTHER PEOPLE DURING CONSTRUCTION. HE SHALL REINF SUPERVISE AND DIRECT THE WORK AND BE RESPONSIBLE FOR ALL CONSTRUCTION. CONCRETE BLOCKS SHALL CONFORM TO THE MINIMUM REQ. OF ASTM C-90 WITH NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE REDUCED IN STRENGTH. f m=1,500psi (1,900psi ON THE NET AREA) THE GENERAL CONTRACTOR SHALL COORDINATE ALL DESIGN PROFESSIONALS DRAWINGS MORTAR SHALL COMPLY WITH THE MINIMUM REQUIREMENTS OF ASTM C270 FOR TYPE AND SPECIFICATIONS, FOR ITEMS WHICH MAY ADVERSELY AFFECT THE STRUCTURE AND M OR S W/ (COMPRESSIVE STRENGTH=2500psi AND 1800psi RESPECTIVELY. SITE NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES AND/OR OMISSIONS. TESTED MORTAR CUBES SHALL ACHIEVE A MINIMUM OF 80% OF THE DESIGN (3) #5 CONT T&B, #4 TIES 0 16' COMPRESSIVE STRENGTH) SUBMITTAL SETS SHALL CONSIST OF A MAXIMUM OF 1 SEPIA AND 2 BLUE LINES, OC ADDITIONAL BLUE LINES WILL BE DISCARDED. BLOCK SHALL NOT BE MOISTENED BEFORE GROUTING. SUBMITTALS TO ENGINEER OF RECORD FOR REVIEW MUST CONTAIN THE GENERAL 8 CONTRACTOR'S STAMP SIGNIFYING HIS REVIEW/ACCEPTANCE. SUBMITTALS SENT WITHOUT ALL CROSS WEBS SHALL BE FULLY BEDDED IN MORTAR AROUND CELLS TO BE GROUTED. THE GS'S REVIEW STAMP WILL BE RETURNED AT HIS EXPENSE AND WITHOUT REVIEW. OC i GROUT FOR FILLED CELLS SHALL BE PLACED AS INDICATED BELOW: ALL SECTIONS AND DETAILS SHALL BE CONSIDERED TO BE TYPICAL OR SIMILAR UNLESS NOTES: SEE PLANS AND PLAN NOTES FOR ANOTHER SECTION OR DETAIL IS REFERENCED ON THE PLANS. 1. DO NOT GROUT UN71L MORTAR HAS SET LOCATION OF GROUTED CELLS J SUFFICIENTLY TO WITHSTAND THE STOP GROUT MIN 1 1/2' BELOW TO 9'-4" PRESSURE OF THE GROUT. WAIT NOT TOP OF UNIT IF GROUTING IS FOUNDATIONS LESS THAN 24 HOURS. STOPPED FOR MORE THAN ONE OC 9'-5" HOUR. CONFORMANCE WITH THE REQUIREMENTS OUTLINED IN THE GEOTECHNICAL SOILS REPORT 2. WAIT A MINIMUM OF 1 HOUR BEFORE () MAX HEIGHT OF LIFT = 5'-0". SHALL BE DETERMINED BY PERFORMING INDUSTRY STANDARD SOIL DENSITY TESTS BY A CERTIFIED TESTING AGENCY. PLACING NEW GROUT ON A PREVIOUS ' ' WAIT 3 TO 5 MINUTES AND SLAB ON GRADE FILLED CELL DETAIL CONSOLIDATE WITH FLEXIBLE CONDITIONS DISCOVERED BY THE GENERAL CONTRACTOR AND/OR GEOTECHNICAL FIELD MAX S-4" CABLE VIBRATOR. REPRESENTATIVE DURING EXCAVATION WHICH MAY PREVENT THE ATTAINMENT OF THE 3 THE MINIMUM CONTINUOUS RECONSOLIDATE AFTER AN ALLOWABLE BEARING PRESSURE STATED IN THE GEOTECHNICAL SOILS REPORT, SHALL BE UNOBSTRUCTED CLEAR AREA IN CELL TO : ' ADDITIONAL 30 MINUTES BEFORE REPORTED TO THE ARCHITECT/ENGINEER. RECEIVE GROUT MUST BE NOT LESS PLASTICITY IS LOST. :...,J 3*0% THAN 3x3. SEE CONCRETE GENERAL NOTES FOUNDA11ON DESIGN VALUES - 2,000PSF (ASSUMED) 4. MORTAR FINS MUST BE REMOVED AS FOR GROUT PROPERTIES c.) EACH LAYER OF FILL SHALL NOT EXCEED 12" THICK AND SHALL BE COMPACTED PRIOR TO BLOCK PLACEMENT PROCEEDS. THE CONTRACTOR MAY USE CONTROL TYPE BLOCK W/ ARCH APPROVAL 400 Ib/LF FOR SPAN INDICATED. IF WALL IS LAID UP NO GREATER REINFORCING: 5. MORTAR DROPPINGS MUST BE KEPT OUT DEFORMED REINFORCEMENT EQUAL TO DURO-WALL IN BED JOINTS AT 16 OC UNO, THAN 5'-0" IN HEIGHT ABOVE THE ALL REINFORCING SHALL BE DOMESTICALLY PRODUCED WITH REBAR CONFORMING TO OF CELLS WHICH ARE TO BE GROUTED. REINFORCING 8" MIN. FOOTING OR PREVIOUS GROUT ASTM -615 FOR GRADE 60 STEEL, AND WELDED WIRE FABRIC (WWF) TO ASTM A-185. LIFT(S), A CLEAN-OUT HOLE SHALL SPLICES AND ANCHORAGE OF REINFORCING SHALL BE AS FOLLOWS UNLESS OTHERWISE 6• MAXIMUM WALL HEIGHT FROM TOP OF FOOTING OR PREVIOUS GROUT POURS NOT BE REQUIRED. OTHERWISE, PROVIDE CLEAN- OUT HOLE WITH Wi@b WIRE FABRIC 12" MIN. LAID UP AT ONE 71ME SHALL BE 12'-0". J ' MINIMUM SIZE OF 3"x3". POURED CONCRETE 36 X BAR DIA (12" MIN) OVERHANGING MORTAR AND DEBRIS GROUTED CELLS 48 X BAR DIA GROUTING DETAIL SHALL BE REMOVED THE CELL WALLS. SEAL PRIOR INSIDE REINFORCEMENT IN WALLS, FOOTINGS AND BEAMS SHALL BE GROUTING BUT AFTER INSPECTION. GROUT PLACEMENT STOPPED FOR (1) HOUR OR MORE SHOULD BE CONTINUOUS AND LAPPED AS SPECIFIED ABOVE, UNLESS NOTED OTHERWISE. HOOK AND LAP ALL CORNER AND STOPPED (1 1/2") BELOW THE TOP OF THE MASONRY UNIT TO PROVIDE INTERSECTING BARS. (SEE REINF DEVELOPMENT DTL BLW). A KEY FOR SUBSEQUENT GROUTING. PCO\ �\� � , c� STOPPING AND RESUMING WORK: RACK BACK 1/2 -UNIT LENGTH IN EACH Voo� ` COURSE. DO NOT TOOTH. CLEAN EXPOSED SURFACES OF SET MASONRY WET UNITS LIGHTLY (IF REQ'D) AND REMOVE LOOSE MAS UNITS AND MORTAR PRIOR TO LAYING FRESH MASONRY. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS. • • 48 BAR DIA. OR I'-6" MIN. DO NOT APPLY CONCENTRATED LOADS TO MASONRY WALLS FOR (7) DAYS. Q Z MAXIMUM CONTROL JOINT SPACING FOR CONCRETE MASONRY UNITS < = SHALL BE THREE (3) X WALL HEIGHT BUT NO FURTHER THAN 50FT. REFERENCE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS. o BACKER ROD AND LED CELL EA SIDE OF I RESILIENT CAULKING MCJ W/ TYP WALL REINF. CORNER REINF DEVELOPMENT DETAIL COVER FOR REINFORCING SHALL BE AS FOLLOWS: 1. a. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH b. CONCRETE EXPOSED TO EARTH OR WEATHER: 16 THRU #18 BARS #5 BAR, W31 OR D31 WIRE AND SMALLER c. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS: #14 AND #18 BARS #11 BAR AND SMALLER 3" 2" 1 1/2- 1 1/2- 3/4w /2"3/4' I >- J O zoo€" SEE SCHED FOR =1 N z z STIRRUP SPCG ¢ oQ � 3/8"x1" VERT (DU>B��EAM EACH SIDE OF TIE L. •r • .4 ` •A f 1--3/8 JOINT ADJUST STIRRUP REINF CONT O LOCATION SLIGHTLY CONTROL JOINT IN TO CLEAR THE CONIC TIE BEAM JOINT BY 2' (MIN) MCJ @ TIE BEAM JOB SITE MIXING OF GROUT SHALL NOT BE PERMITTED. TESTING SHALL CONFORM TO ASTM C1019. SEE TEST MOLD DETAIL BELOW. SEE SCHEDULE UNDER CONCRETE NOTES FOR COMPRESSIVE STRENGTH AND SLUMP REQUIREMENTS. NOTE- GROUT TEST PRISM (4) 8x8x16 CMU BLOCKS REQUIRED COVER UNITS USING ABSORPTIVE PAPER TOWELLING W/ TAPE 3"x3"x1 5/8" WOOD BLOCK FRONT BLOCK REMOVED FOR CLARITY DETAIL MASONRY GROUT TEST MOLD (ASTM C-1019. MASONRY QQNT TYPICAL MECHANICAL OPENING DETAIL: NOTE: GC TO CONTACT ENGINEER IF OPENING EXCEEDS SIZE AND AND SPACING SHOWN. VCONCRETE FILLED ADD TYP WALL PC "U" LINTEL W/ /-ADD TYP WALL REINF THIS (2) #5 & 8" BRG �/ REINF THIS LOCATION O EACH END LOCATION 4'* SCHED REINF NOTES: I . DETAIL HAS BEEN DESIGNED TO MEET ALL ANTICIPATED LOADING CONDITIONS OUTLINED IN THE 2017 EDITION OF THE FLORIDA BUILDING CODE FOR A 140MPH, RISK CATEGORY 11, EXPOSURE "C" WIND LOAD EVENT. 2. SEE CIVIU51TE PLAN (BY OTHERS) FOR LOCATION OF DUMPSTER ENCLOSURE. 3. PROVIDE (2) FILLED CELLS AT DISCONTINUOUS ENDS AND (3) FILLED CELLS AT INTERSECTING CORNERS (TYP.). 4. SEE CIVIL/SITE PLAN (BY OTHERS) FOR REQUIRED, WIDTH, AND LENGTH OF DUMPSTER ENCLOSURE. 28 DAY STRENGTH MATCH FTG REINFORCING SCHEDULE FOUNDATION WALL H FOOTING SIZE (W X L) CMU WIDTH (NOMINAL) NEOPRENE PRE- FORMED GASKET II #-1/2" THRU-WALL VERTICAL WALL REINFORCING REINF S-0" x CONT '� �vPLAN (3) #5 CONT T&B, #4 TIES 0 16" T/ FTG EL EE OC 5'-5" NOTES: CONTROL JOINT 8 (3) #5 CONT T&B, #4 TIES 0 16' OC #5 0 48' OC 6'-9" TO 8'-0" 1. THRU-WALL JOINT SHALL BE CONTINUOUS WITHOUT INTERRUPTION FROM 8 �� OC CL OC i TO 8'-8" FOUNDATION TO TOP OF WALL. 8 (3) #5 CONT T&B, #4 TIES 012" o J OC 2. TERMINATE TYPICAL HORIZONTAL JOINT REINFORCING AT JOINT. TO 9'-4" 4'-4" x CONT 8 (4) #5 CONT T&B, #4 TIES 012' \ 3. MAXIMUM SPACING OF CONTROL JOINTS SHALL BE (3 x WALL HEIGHT) OR OC 9'-5" TO 10'-0" 4'-4" x CONT 8 50'-0", WHICHEVER IS LESS. OC ' OC SLAB ON GRADE FILLED CELL DETAIL MASONRY CONTROL JT (MCJ) MIN 3'-4" MAX S-4" MIN S-4" .!~ ��:-•:.•:.'~ BETWEEN OPNGS BETWEEN OPNGS FILL CORE SOLID W/ RESIL CAULKING TYP M E C H O P N G TH R U FTG MORTAR FOR FULL HT 15# BUILDING FELT VERTICAL REINFORCEMENT IN WALLS SHALL BE SECURED AND LATERALLY SUPPORTED BON BREAKER TEMPORARY BRACING AND SHORING OF WALLS TO PROVIDE STABILITY b.) COMPACTION OF THE SOIL IN THE FIELD SHALL BE MONITORED/CONTROLLED BY A :...,J REPRESENTATIVE OF A QUALIFIED LABORATORY. DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. t -CONTROL JOINT PROVIDE GROUT FILLED PRECAST U -LINTELS WITH (1) #5 CONT AT ALL OPEN(NGS WHERE c.) EACH LAYER OF FILL SHALL NOT EXCEED 12" THICK AND SHALL BE COMPACTED PRIOR TO CONCRETE BEAMS ARE NOT SHOWN OR NOTED. MINIMUM UNFILLED LINTEL CAPACITY = THE CONTRACTOR MAY USE CONTROL TYPE BLOCK W/ ARCH APPROVAL 400 Ib/LF FOR SPAN INDICATED. MASONRY CONTROL J T (MCJ) ALTERNATE HORIZONTALLY REINFORCE WALLS WITH LADDER TYPE (ASTM A-82, #9 GAGE WIRE) PATTERNS SHALL BE APPROXIMATELY SQUARE W/ RATIO OF LONG SIDE TO SHORT SIDE DEFORMED REINFORCEMENT EQUAL TO DURO-WALL IN BED JOINTS AT 16 OC UNO, NOT TO EXCEED 1.5 TO 1.0. MEASURED VERTICALLY. PLACE PER MFR INSTRUCTIONS. LAP ALL HORIZONTAL JOINT REINFORCING 8" MIN. NOTES: I . DETAIL HAS BEEN DESIGNED TO MEET ALL ANTICIPATED LOADING CONDITIONS OUTLINED IN THE 2017 EDITION OF THE FLORIDA BUILDING CODE FOR A 140MPH, RISK CATEGORY 11, EXPOSURE "C" WIND LOAD EVENT. 2. SEE CIVIU51TE PLAN (BY OTHERS) FOR LOCATION OF DUMPSTER ENCLOSURE. 3. PROVIDE (2) FILLED CELLS AT DISCONTINUOUS ENDS AND (3) FILLED CELLS AT INTERSECTING CORNERS (TYP.). 4. SEE CIVIL/SITE PLAN (BY OTHERS) FOR REQUIRED, WIDTH, AND LENGTH OF DUMPSTER ENCLOSURE. 0 i (2) #5 CONT IN KO BLK 0 T/ WALL - BRICK WHERE INDICATED, REF: ARCH DWGS NOTES: 1. PLACE THRU-WALL CONTROL JOINTS AT 50'-0" OC MAX AND 20'-0" FROM CORNERS. DO NOT CONTINUE HORIZONTAL REINF ACROSS CONTROL JOINTS. SEE CELL W/ MATCH OWLS 0 FDN. SEE SCH FOR SPACING EJ 6' SLAB -ON -GRADE REINF. W/ 6x6 �- W2.1 xW2.1 WWF SLAB BOT BARS EQ SEE EQ SCS: SECTION SEE SCH N.T.S. - � (TYPICAL DUMPSTER • ENCLOSURE WALL) CONCRETE. ALL CONCRETE SHALL HAVE THE FOLLOWING MIN. PROPERTIES: LOCATION 28 DAY STRENGTH DUMPSTER WALL REINFORCING SCHEDULE FOUNDATION WALL H FOOTING SIZE (W X L) CMU WIDTH (NOMINAL) FOOTING REINFORCING 3,000 psi WALL REINFORCING UP TO 5'-4" S-0" x CONT 8 (3) #5 CONT T&B, #4 TIES 0 16" OC #5 0 48" OC 5'-5" TO 6'-8" S-0" x CONT 8 (3) #5 CONT T&B, #4 TIES 0 16' OC #5 0 48' OC 6'-9" TO 8'-0" S-8" x CONT 8 (3) #5 CONT T&B, #4 TIES 012" OC 15 032" OC 8'-1" TO 8'-8" S-8" x CONT 8 (3) #5 CONT T&B, #4 TIES 012" OC #5 0 24" OC 8'-9" TO 9'-4" 4'-4" x CONT 8 (4) #5 CONT T&B, #4 TIES 012' OC #5 016" OC 9'-5" TO 10'-0" 4'-4" x CONT 8 (4) #5 CONT T&B, #4 TIES 0 12" OC #6 016- OC 0 i (2) #5 CONT IN KO BLK 0 T/ WALL - BRICK WHERE INDICATED, REF: ARCH DWGS NOTES: 1. PLACE THRU-WALL CONTROL JOINTS AT 50'-0" OC MAX AND 20'-0" FROM CORNERS. DO NOT CONTINUE HORIZONTAL REINF ACROSS CONTROL JOINTS. SEE CELL W/ MATCH OWLS 0 FDN. SEE SCH FOR SPACING EJ 6' SLAB -ON -GRADE REINF. W/ 6x6 �- W2.1 xW2.1 WWF SLAB BOT BARS EQ SEE EQ SCS: SECTION SEE SCH N.T.S. - � (TYPICAL DUMPSTER • ENCLOSURE WALL) CONCRETE. ALL CONCRETE SHALL HAVE THE FOLLOWING MIN. PROPERTIES: LOCATION 28 DAY STRENGTH SLUMP MAX AGGR. FOUNDATION 3,000 psi 4" f 1' 1 1/2 SLAB -ON -GRADE UP TO 4" THICK 3,000 psi i'±- 1 1 1 2 SLAB -ON -GRADE (OVER 4" THICK) 4,000 psi 4" f 1 1 1/2m GROUT FOR FILLED CELLS 2,500 psi 8" f 11" 3/8* SLAB THICKNESS IN - NOTES: 1• SLUMP FOR RAMPS AND SLOPING SURFACES SHALL NOT EXCEED 4'. 5 2. SEE MASONRY GENERAL NOTES FOR GROUT TESTING REQUIREMENTS. VERTICAL REINFORCING MUST HAVE A MINIMUM CLEARANCE OF 1/2" TO INSIDE FACE. CONCRETE PROPERTIES SHALL BE VERIFIED THROUGH INDUSTRY STANDARD TESTING VERTICAL BAR LAP = 48 x BAR DIAMETER. SEE FILLED CELL DETAIL BELOW FOR PROCEDURES BY A CERTIFIED TESTING AGENCY. MIN. TEST REQUIRED SHALL INCLUDE ADDITIONAL INFORMATION. SLUMP AND CYLINDER BEAKS FOR COMPRESSIVE STRENGTH. FINDINGS SHALL BE SUBMITTED 1121131151181201 TO THE ARCH./ENG. FOR REVIEW. NOTES: CONCRETE WORK SHALL CONFORM TO ACI 301 (LATEST EDITION) SPECIFICATIONS FOR 1 • SEE FOUNDATION PLANS FOR ALL ' i .: STRUCTURAL CONCRETE FOR BUILDINGS. VERT REINF. REQ. TYP VERTICAL STOP VERTS 2" FROM REINFORCING SIZE & SPACING ' TOP OF WALL & CONCRETE MIX DESIGN SUBMITTALS SHALL MEET THE FOLLOWING CRITERIA: SHALL BE ABOVE AND BELOW ALL PROVIDE STANDARD ACI :: HOOK (TYP) 1. EACH MIX DESIGN SHALL BE LABELED TO INDICATE THE AREA IN WHICH THE CONCRETE IS WALL OPENINGS. VERT BAR CENTERED IN TO BE PLACED. FAILURE TO DO SO WILL RESULT IN THE REJEC11ON OF SUBMITTALS. 2. EXTEND ALL VERTICAL WALL •` '� FILLED CELL 2. PROPOSED MIX DESIGN SHALL BE ACCORDANCE WITH ACI 301 METHOD 1 OR METHOD 2 . REINFORCEMENT TO WITHIN 2" DOWELS SAME AS VERT SUPPORTING DATA SHALL BE PROVIDED IN TABULAR FORM FOR EACH SEPARATE PROPOSED OF TOP OF WALL OR BEAM BARS MIX. UNLESS NOTED OTHERWISE. TERMINATE REINFORCING WITH -� HORIZ JOINT REINF ® 3. ENTRAPPED AIR CONTENT SHALL NOT EXCEED 37. STANDARD ACI 90 DEGREE 16" OC VERT SPACING 4. ADMIXTURES USED TO ENTRAIN AIR ARE NOT ACCEPTABLE. HOOK IF ROOF JOISTS AND/OR y W n �o TRUSSES BEAR ON TOP OF cn o STANDARD HOOK SITE ADDED WATER IS NOT ACCEPTABLE. ADDING WATER TO THE MIX WILL RESULT IN WALL AND THERE IS NO m ;� (ALTERNATE SIDES) REJECTION OF THE RESULTS BY THE ENGINEER OF RECORD., PARAPET. IF PARAPET EXISTS, Nod w HOOK IS NOT REQUIRED. � ILLJ ,' ' :` • " . SLAB ON GRADE FILLED CELL DETAIL Lu. UNLESS SPECIFICALLY STATED OTHERWISE IN THE GEOTECHNICAL SOILS REPORT, THE .!~ ��:-•:.•:.'~ FOLLOWING MINIMUM CRITERIA SHALL BE ADHERED TO. a.) INTERIOR FILL SHALL BE COMPACTED TO A MINIMUM OF 95% OF THE MODIFIED PROCTOR VERTICAL REINFORCEMENT IN WALLS SHALL BE SECURED AND LATERALLY SUPPORTED MAXIMUM DRY DENSITY TEST (ASTM D1557). t AGAINST DISPLACEMENT AT INTERVALS NOT EXCEEDING 192 x BAR DIAMETER OR 10 FT b.) COMPACTION OF THE SOIL IN THE FIELD SHALL BE MONITORED/CONTROLLED BY A WHICHEVER IS LESS WHENEVER A CLEANOUT IS REQUIRED. SEE GROUTING DETAIL NOTE REPRESENTATIVE OF A QUALIFIED LABORATORY. FOR CLEANOUT REQUIREMENTS. c.) EACH LAYER OF FILL SHALL NOT EXCEED 12" THICK AND SHALL BE COMPACTED PRIOR TO REINFORCE MASONRY OPENINGS GREATER THAN 1'-0" WIDE, WITH HORIZ JT REINF PLACED PLACEMENT OF THE NEXT LAYER. IN (2) HORIZ JOINT'S APPROXIMATELY 8" APART, IMMEDIATELY ABOVE THE LINTEL AND MAXIMUM SPACING OF CONTROL JOINTS SHALL BE AS SHOWN IN THE TABLE BELOW. IMMEDIATELY BELOW THE SILL EXTEND REINFORCING A MINIMUM OF 2'-0" BEYOND PATTERNS SHALL BE APPROXIMATELY SQUARE W/ RATIO OF LONG SIDE TO SHORT SIDE JAMBS OF THE OPENING EXCEPT AT CONTROL JOINTS. SEE PLAN FOR ADDITIONAL NOT TO EXCEED 1.5 TO 1.0. REQUIREMENTS. SLAB THICKNESS IN - 4 5 6 7 8 9 10 SPACING (FT) w 1121131151181201 F7( 23 2 MIX DESIGNS CONTAINING AGGREGATE LESS THAN 3/4" ARE NOT ACCEPTABLE CUT SLAB AS SOON AS AGGREGATE DOES NOT DISLODGE (MUST BE WITHIN THE SAME DAY AS THE CONC. WAS PLACED) CARE SHALL BE TAKEN BY THE GENERAL CONTRACTOR WHEN DETERMINING THE LOCATION OF SJ'S AND CSS TO ENSURE SLAB JOINTS DOES NOT READ THROUGH THE ARCHITECTURAL FINISHES. WAREHOUSE SLABS SHALL BE POWER -TROWELLED TO A HARD, SMOOTH BURNISHED FINISH. THE FINAL TROWEL PASS SHALL BE DONE BY MACHINE - NOT BY HAND. WITHIN 30 MINUTES OF THE FINAL TROWEL PASS, THE FLOOR SHALL BE CURED WITH EUCLID'S SUPER REZ-SEAL OR APPROVED EQUAL. SLAB THICKNESS SHALL BE INCREASED AS REQUIRED TO PROVIDE ADEQUATE SUPPORT FOR CRANE LOADS WITHOUT CRACKING SLAB. REVISIONS DUMPSTER ENCLOSURE 1 RINEHART 55 ASSOCIATES LLC 145 1 RINEHART ROAD, SANFORD, FL 32771 Is w �a � F7( m� ° 0r U ��� WW1. 3 �w ,fa as t- c O oZ � z z LLJ z qMu � a�Q oou ri0o iii <S ?u,p WBO�poic y W n �o m A oe� "fine..L Z Ov Nei 1i1 �.� IYI gU .� Ln Nod w � ILLJ �< . Lu. / • • • Un • • Is ```A,.. ..,,/'' �� M. gF�'�.,� No. 554 a ATE F _ N A 1. E DRAWN BY DATE EDJ 02-09-18 CHECKED BY DATE RMB 05-10-18 SCALE N.T.5. JOB NUMBER 2035 FILE NAME 2035-5TK.DWG SHEET D -I w �a � F7( m� ° 0r U ��� WW1. 3 �w ,fa as t- c O oZ � z z LLJ z qMu � a�Q oou ri0o iii <S ?u,p WBO�poic y W n �o m A oe� "fine..L Z Ov Nei 1i1 �.� IYI gU Nod w � ILLJ �< . ```A,.. ..,,/'' �� M. gF�'�.,� No. 554 a ATE F _ N A 1. E DRAWN BY DATE EDJ 02-09-18 CHECKED BY DATE RMB 05-10-18 SCALE N.T.5. JOB NUMBER 2035 FILE NAME 2035-5TK.DWG SHEET D -I FIELD VERIFY & CONNECT NEW 1" CW SERVICE LINE TO CW MAINS—FOR CONT. REFER TO CIVIL UTILITY PLAN CONNECT NEW 4 SAN.MAINS— REF UTILITY PLAN FO EWH-1 MC STAND. RE WATER HC DETAIL ON OFFICE PLUMBING FLOOR PLAN SCALE:1 /4" = 1'-0" VALVE HB -1 II FIELD VERIFY & CONNECT NEW 1" CW SERVICE LINE TO CW LL=1 MAINS—FOR CONT. REFER TO CIVIL UTILITY PLAN --i 1" 1" MARKUPS # I DATE I BY I 155UE I 05-07-18 1 J5V I PER MARKUPS. 0 L 105-24-18 1 J5V I PER MARKUPS. STANCOR "JR" AND DIRECT WIRE ELEVATOR OIL—MINDER SYSTEMS 1. Stancor Model submersible effluent pump _HP, volt, 3600 RPM, _" discharge connection (shown as example) e' t 2. Check valve (2") R STANDARD CONTROL BOX a� -� 3. Stancor Oil -Minder V, 3d control system with built-in -' DIMENSIONS, SE -40, 5D SINGLE PHASE - 7.5"x 6.5"x 4" DEEP audible and visual alarm when pump Ao THREE PHASE 5TANDARD CONTROL BOK does not run due to oil in pit or high liquid or high amperage condition. Provide silencing button for audible go 14 x 12" x 6.5" DEEP REVISIONS alarm built into panel. Panel shall have two contacts for a remote alarm location (one each for oil and high water or amperage alert). 4. Junction box available as a factory option with or without a lockable pump disconnect switch 3 # DATE BY 55UE 5. All buried pump pressure discharge piping shall be protected with tapecont CT corrosion protection tape POWER IN 1 07-13-18 N5 I'ERtiLG.DtFT.COMM. G. Purnp cable, probe table, high liquid alarm cable, and pump ''on" float cable (16 ft. lengths standard) 7. High liquid alarm float with clamp device to mount to pump discharge piping "DRY" CONTACTS IN PANEL S. Pump On float TO BUILDING RMS 9. Oil sensing probe FOR HIGH WATER, AMPS AND SEPARATE OIL FAULT SIGNALS Items 1, 3, 6, 7, 8 and 9 provided by Stancor as a Standard Package STANCOR ELEVATOR PIT SYSTEMS (PRODUCT#SE-SE100 INSTALL WATER TEMPERATURE LIMITING DEVICE(S)WHERE REQUIRED PER SECTION 607 OF FBCP TO LIMIT TEMPERED WATER TO 1107 MAX. / / INSTALL VALVES WHERE REQUIRED PER SECTION 606 OF FBCP / OPTIONAL NE.h9A 4X 4 CONDUIT, PER NEC STANCOR J -BOX REQUIREMENTS WITH OPTIONAL LOCKPBLE SE -4D, 50, 1 D0, AHS -1 DOHH, 5E-200, AHS -250 HH, nuntn DISCONNECT (ALL MODELS} MIN. PIT SIZE 24" X 24" X 24" WITH STD FLOAT & PROBE ARRANGEMENT y MIN. PIT SIZE 12" X 12" X 18 D" (SE -40, 50) USING OPTIONAL OM -300 VERTICAL FLOAT & PROBE ARRANGEMENT NIN. PIT SIZE FOR PHYSICAL FIT, FINAL SIZE TBD BY PUMP FLOW RATE (ALL MODELS) AND MAXIMUM 10 STARTS PER HOUR VALVE COVER r— FLOOR EWH-1 MOUNT HIGH ON STAND. REFER TO TYPICAL WATER HOT WATER STAND DETAIL ON P-0 VENT TERMINATION THRU SIDE WALL SHALL BE IN ACCORDANCE TO SECTION 903.6 OF FBCP.PROVIDE ACCEPTABLE MESH SCREEN TO PREVENT BIRDS AND RODENTS INTRUSION i r1_1 \ \3"VTW 2"V 1 /� 1 INSTALL CLEANOUTS PER SECTION 2"V \ \ 708 OF FBCP I I � I L 1 12 V I \ 3n PVC WASTE LINE FROM RUN UNDERGROUND. REF 2"V P-2 FOR CONTINUATION � 1 2"V WC -1 1 2"V 3" > 2"V ECO / 2—WAY / 4" 5k__� 41 3" 00 4" 4" I MS -1 4" SAN.LINE. REFER I T / TO CIVIL UTILITY �/ v PLAN FOR CONT. 4" / WC -1 OFFICE DOMESTIC WATER RISER DIAGRAM SCALE: N.T.S. AAV I I WC -1 OFFICE SANITARY RISER DIAGRAM SCALE: N.T.S. f��n�l2a.r-f 72k AAV PERMIT #, 'P' I2V AAV I 12V I 4n WC TYP, WC -1 3n 2" PLUMBING FLOOR PLAN RINEHART 55 ASSOCIATES LLC 145 1 RINEHART ROAD, 5ANFORD, FL 32771 LEI J Puma INFUR.P"On pISCHARGE PIPE ,zO Type! ®Sump Pump{s) 030+ stoinleea Steal Wm3O?po' U p 5040 Galvanized Steel ❑ Sch80 PVC Pipe ¢i vu'iz a'�S PSti @�z ELEU ALARM FLOAT VOLTS: ❑ z., � N Bo oz rzui <s0 ;0a In R..a BHP -.1.0 D3 P� P °" FLOArOUTPUT 9 ELEu ---- -2 SR-1 FLA: 12 g4�o�o LRA:6O EWH-1 MOUNT HIGH ON STAND. REFER TO TYPICAL WATER HOT WATER STAND DETAIL ON P-0 VENT TERMINATION THRU SIDE WALL SHALL BE IN ACCORDANCE TO SECTION 903.6 OF FBCP.PROVIDE ACCEPTABLE MESH SCREEN TO PREVENT BIRDS AND RODENTS INTRUSION i r1_1 \ \3"VTW 2"V 1 /� 1 INSTALL CLEANOUTS PER SECTION 2"V \ \ 708 OF FBCP I I � I L 1 12 V I \ 3n PVC WASTE LINE FROM RUN UNDERGROUND. REF 2"V P-2 FOR CONTINUATION � 1 2"V WC -1 1 2"V 3" > 2"V ECO / 2—WAY / 4" 5k__� 41 3" 00 4" 4" I MS -1 4" SAN.LINE. REFER I T / TO CIVIL UTILITY �/ v PLAN FOR CONT. 4" / WC -1 OFFICE DOMESTIC WATER RISER DIAGRAM SCALE: N.T.S. AAV I I WC -1 OFFICE SANITARY RISER DIAGRAM SCALE: N.T.S. f��n�l2a.r-f 72k AAV PERMIT #, 'P' I2V AAV I 12V I 4n WC TYP, WC -1 3n 2" PLUMBING FLOOR PLAN RINEHART 55 ASSOCIATES LLC 145 1 RINEHART ROAD, 5ANFORD, FL 32771 LEI J ,zO N U wu Wm3O?po' U rctiivW ¢i vu'iz a'�S PSti @�z w 9>yJ HE N Bo oz rzui <s0 ;0a In R..a -8 Blue N �R�wpt IM g4�o�o z OE u O xx U qua WW �o (GEa()) a LU LN am Hr r ``111111111►1��,' . BFgT gyp, •��(;ENS� No. 55428 ST /O N A G EOG\ '�'/1111111111`` �� DRAWN DY DATE EDJ 02-09-18 CHECKED DY DATE RMB 05-10-18 SCALE JOB NUMBER 2035 FILE NAME 2035-5TR. DWG SHEET P-1 AIR HANDLING UNIT DRAIN PAN —� DRAIN LINE SHALL BE SAME SIZE AS NIPPLE ON EQUIPMENT REMOVABLE CLEANOUT REMOVABLE CLEANOUT \ WITH 1/8" HOLE IN CAP PITCHED DOWN TOWARD DRAIN - 1 /4"/FT. MIN._ 1" MIN. EASILY REMOVABLE CONNECTION 4" MIN. DEPTH OF SEAL CONDENSATE DRAIN TRAP DETAIL NOT TO SCALE 60" MAX. DUCT HANGER STRAP 1" NOTE: SIZE AND RATING OF HANGERS AND SUPPORTS SHALL BE PER LATEST "SMACNA" STANDARDS. TYPICAL DUCT HANGER DETAIL SCALE: N.T.S NOTE: SEE ROOF FRAMING PLANS FOR SUPPORTING BEAM AND COLUMN SIZE AND GAGE. BOTH SUPPORTING BEAMS AND SUPPORTING COLUMNS SHALL BE MIN. 14ga. RTU TO STAND OPTION #2: FASTEN RTU TO STAND (1) SIMPSON LTT19 TENSION TIE (OR EQUAL) W/ (6; #14 TEK SCREWS TO UNIT AND (1) J"O BOLT TO STAND EACH CORNER (TOTAL OF 4 TENSION TIES) ROOF RACK — BY (4) J"0 BOLTS EACH LEG—TYP. MAXIMUM SPACING SHALL BE PER SMACNA DUCT CONSTRUCTION STANDARDS #12 SHEET METAL SCREW 2" MIN 22GA. DUCT STRAP #12 SHEET METAL SCREW (TYP.) 2" WIDE METAL METAL BRACKET STRAP AROUND THE AIR DUCT SUPPLY AIR DUCT SUPPLY AIR REGISTER SPIRAL DUCT WITH SIDE DISCHARGE DIFFUSER NTS ROUND DUCT SPECIFICATION EXPOSED ROUND DUCTWORK SHALL BE 24 GAUGE, SINGLE WALL GALVANIZED STEEL, SPIRAL LOCKSEAM. FITTINGS SHALL BE SINGLE WALL GALVANIZED STEEL, STANDING SEAM OR SOLID WELDED CONSTRUCTION. ELBOWS SHALL BE STANDING SEAM, GORED ELBOWS. GRILLE COLLARS SHALL BE ATTACHED TO THE DUCTWORK WITH POP RIVETS WITH A FINISHING FILLET OF ELASTOMER SEAL AT THE JUNCTION OF THE COLLAR TO THE DUCT. DUCT—TO—DUCT JOINTS SHALL BE MADE WITH THE SPIRAL SEAM ROTATED SO THAT THE STANDING SEAM FORMS A CONTINUOUS HELICAL PATTERN ACROSS THE JOINT. ALL DUCTWORK AND FITTINGS SHALL BE MANUFACTURED IN ACCORDANCE WITH 2005 EDITION OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS AS REFERENCED IN CHAPTER 15 OF FBCM. ALL EXPOSED ROUND DUCTWORK AND FITTINGS SHALL BE CLEANED OF ALL OILS AND COATINGS PRIOR TO INSTALLATION AND PROVIDED WITH A MILL PHOSPHITIZED FINISH ("PAINT GRIP% "ZINC GRIP", OR SIMILAR ETCH TREATMENT) TO ALLOW THE DUCTWORK TO BE PAINTED. SECTION A—A_ OTE: IBOTH OPTION #1 & OPTION #2 I ARE SHOWN, HOWEVER FOR INSTALLATION PURPOSES EITHER IOPTION #1 OR OPTION #2 MAY I BE USED, AS BOTH ARE NOT 1 NECESSARY. NEW RTU UNIT - (5001b MAX.) SEE SPECS __w_ o� to UNISTRUT ROOF RACK BASE PLATE-TYP. NOTEt THIS DETAIL HAS BEEN DESIGNED TO RESIST A 150M.PH, WIND EVENT. RTU TO STAND OPTION #1: FASTEN RTU TO STAND W/ (1) J"O BOLT EACH CORNER (TOTAL OF 4 BOLTS PER UNIT). MIN.STAND HEIGHT PER FBC TABLE:1510.10 A A (4) UNISTRUT P1000 — OR EQUAL — (TWO EACH END OF UNIT) FASTENED TO EXISTING RIBBED ROOF DECK EACH WIND CLAMP W/ (1) "O BOLT (TYP. W/ S-5 WIND CLAMPS—TYP. EACH RIB LOCATION) CON D EN SER UNIT ON STANDING SEAM ROOF DECK AIRFLOW TWORK 'RED ELBOW WITH BLE WALL TURNING VANES & FRAME MITERED ELBOW FITTING 9RANCH DUCTWORK AIRFLOW AIRFLOW )OUBLE WALL TURNING ✓ANES & FRAME SPLITTER DAMPER W/ ADJUSTMENT ROD MITERED TEE FITTING OSA DUCT TO AHU AUX.DRAIN PAN WITH OVER FLOW CUT OF SWITCH TIED INTO COOLING MODE PER 2017 FBCM 307.2.3 - , VOLUME DAMPER BEARING BRANCH DUCT LOCKING QUADRANT LEVER TAP COLLAR TRUNK DUCT BRANCH DUCT CONNECTION FITTING DUCTWORK FITTING DETAIL NOT TO SCALE AC MODEL PER UNIT SCHEDULE ROOF LEVEL COND. UNIT SUPPLY AIR SUPPLY AIR DUCT TO SPACE - ELECTRIC HEATER ON DISCHARGE - PROVIDE FULL SIZE SHEET METAL WITH OSA OPENING ON ONE SIDE & FASTEN OSA DUCT TO OPENING ON SHEET METAL AIR HANDLING UNIT REFRIGERANT AND VAPOR LINES FROM ABOVE ROUTED TO CONDENSER UNIT. REF. DWG. M200 C CONDENSATE DRAIN WITH TRAP NEOPRENE ISOLATION PAD C 2"X2"X1 /4" ANGLE WELDED SUPPORT FRAME UNDER UNIT r— FLOOR SLAB ON 3 SIDES REFRIG.PIPING THRU ROOF JACK. SEAL ALL AROUND WATER TIGHT ELEVATION OF FLOOR MOUNTED AHU SYSTEM SCALE: N.T.S MAXIMUM SAG 1/2" PER FOOT OF SUPPORT SPACING FLEX DUCT i of 5'-0" MAXIMUM FLEX DUCT SUPPORT DETAIL NOT TO SCALE METAL STRAP 2" MINIMUM NOTES: 1). DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM A CONNECTION BEFORE BENDING. 2). SUPPORT SYSTEM MUST NOT DAMAGE DUCT OR CAUSE OUT—OF—ROUND SHAPE. MARKU P5 # DATE 8Y ISSUE I 05 07 18 JSV PER MARKUPS, 2 05-74- 18 1 J5V PER MARKUPS. REVISIONS # I DATE I BY I 155UE I 07-13-18 1 N5 IPEP 81.G.DEPT.COMM. HVAC DETAILS RINEHART 55 ASSOCIATES LLC 145 1 RINEHART ROAD, 5ANPORD, FL 32771 0 w uj Z3 z g> NN u3 00 oarrararrrrr/ • �.ai�raarri, /.rrrrarri ; • M. 13 .554 ST E �0.� ' ORIOp' fit`' /I/ON A '11111'1 I►�►�` DRAWN 8Y DATE EDJ 02-09-18 CHECKED DY DATE RMB 05-10-18 JOU NUMDFR 2035 FILE NAME 2035-5TR.DWG SHEET oz, J rom �8 Oui; W U m�uFo... ri�z R� 9a.p g a ZVI go z o tem yt z °���o�ma 0 HE= �b�~zo� 0 6>_ cF, O ii N Vv � )�aN�g,= l) U' za3 k i Ud E �o ow d LU 59 z �u 2 M. 13 .554 ST E �0.� ' ORIOp' fit`' /I/ON A '11111'1 I►�►�` DRAWN 8Y DATE EDJ 02-09-18 CHECKED DY DATE RMB 05-10-18 JOU NUMDFR 2035 FILE NAME 2035-5TR.DWG SHEET AIR HANDLING UNIT DRAIN PAN —� DRAIN LINE SHALL BE SAME SIZE AS NIPPLE ON EQUIPMENT REMOVABLE CLEANOUT REMOVABLE CLEANOUT \ WITH 1/8" HOLE IN CAP PITCHED DOWN TOWARD DRAIN — 1 /4"/FT. MIN. 1" MIN. \ EASILY REMOVABLE CONNECTION 4" MIN. DEPTH OF SEAL CONDENSATE DRAIN TRAP DETAIL NOT TO SCALE 60" MAX. DUCT HANGER STRAP 10 1" NOTE: SIZE AND RATING OF HANGERS AND SUPPORTS SHALL BE PER LATEST "SMACNA" STANDARDS. TYPICAL DUCT HANGER DETAIL SCALE: N.T.S NOTE: SEE ROOF FRAMING PLANS FOR SUPPORTING BEAM AND COLUMN SIZE AND GAGE. BOTH SUPPORTING BEAMS AND SUPPORTING COLUMNS SHALL BE MIN. 14go. RTU TO STAND OPTION #2: 2" MIN 22GA: DUCT STRAP METAL BRACKET SUPPLY AIR REGISTER #12 SHEET METAL SCREW #12 SHEET METAL SCREW (TYP. ) 2" WIDE METAL STRAP AROUND THE AIR DUCT SUPPLY AIR DUCT SPIRAL DUCT WITH SIDE DISCHARGE DIFFUSER NTS ROUND DUCT SPECIFICATION EXPOSED ROUND DUCTWORK SHALL BE 24 GAUGE, SINGLE WALL GALVANIZED STEEL, SPIRAL LOCKSEAM, FITTINGS SHALL BE SINGLE WALL GALVANIZED STEEL, STANDING SEAM OR SOLID WELDED CONSTRUCTION. ELBOWS SHALL BE STANDING SEAM, GORED ELBOWS. GRILLE COLLARS SHALL BE ATTACHED TO THE DUCTWORK WITH POP RIVETS WITH A FINISHING FILLET OF ELASTOMER SEAL AT THE JUNCTION OF THE COLLAR TO THE DUCT. DUCT—TO—DUCT JOINTS SHALL BE MADE WITH THE SPIRAL SEAM ROTATED SO THAT THE STANDING SEAM FORMS A CONTINUOUS HELICAL PATTERN ACROSS THE JOINT. ALL DUCTWORK AND FITTINGS SHALL BE MANUFACTURED IN ACCORDANCE WITH 2005 EDITION OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS AS REFERENCED IN CHAPTER 15 OF FBCM. ALL EXPOSED ROUND DUCTWORK AND FITTINGS SHALL BE CLEANED OF ALL OILS AND COATINGS PRIOR TO INSTALLATION AND PROVIDED WITH A MILL PHOSPHITIZED FINISH ("PAINT GRIP", "ZINC GRIP", OR SIMILAR ETCH TREATMENT) TO ALLOW THE DUCTWORK TO BE PAINTED. :O:li 1:0: UNISTRUT (4) J"0 BOLTS `— ROOF RACK BASE PLATE—TYP. EACH LEG—TYP. SECTION A—A_ F NOTE: IBOTH OP11ON #1 & OPTION #2 I ARE SHOWN, HOWEVER FOR INSTALLATION PURPOSES EITHER IOPTION #1 OR OPTION #2 MAY I BE USED, AS BOTH ARE NOT NECESSARY. FASTEN RTU TO STAND (1) SIMPSON fi_ NEW RTU UNIT ! LTT19 TENSION TIE (OR EQUAL) W/ (6) I_ (5001b MAX.) #14 TEK SCREWS TO UNIT AND (1) J"0 SEE SPECS BOLT TO STAND EACH CORNER (TOTAL OF 4 TENSION TIES) 001 to ROOF RACK — BY OTHERS N❑TEi THIS DETAIL HAS BEEN DESIGNED TO RESIST A 150M,PH. WIND EVENT, RTU TO STAND OPTION #1: FASTEN RTU TO STAND W/ (1) J"O BOLT EACH CORNER (TOTAL OF 4 BOLTS PER UNIT). MIN.STAND HEIGHT PER FBC TABLE:1510.10 A A (4) UNISTRUT P1000 — OR EQUAL — (TWO EACH END OF UNIT) FASTENED TO EXISTING RIBBED ROOF DECK WIND CLAMP W/ (1) "m BOLT (TYP. EACH W/ S-5 WIND CLAMPS—TYP. EACH RIB LOCATION) -------------------------------------------- CONDENSER UNIT ON STANDING SEAM ROOF DECK AIRFLOW TWORK -RED ELBOW WITH BLE WALL TURNING VANES & FRAME MITERED ELBOW FITTING 9RANCH DUCTWORK AIRFLOW )OUBLE WALL TURNING ✓ANES & FRAME SPLITTER DAMPER W/ ADJUSTMENT ROD AIRFLOW MITERED TEE FITTING OSA DUCT TO AHU AUX.DRAIN PAN WITH OVER FLOW CUT OF SWITCH 11ED INTO COOLING MODE PER 2017 FBCM 307.2.3 ---� VOLUME DAMPER BEARING --z BRANCH DUCT LOCKING QUADRANT LEVER TAP COLLAR TRUNK DUCT BRANCH DUCT CONNECTION FITTING DUCTWORK FITTING DETAIL NOT TO SCALE AC MODEL PER UNIT SCHEDULE ROOF LEVEL COND. UNIT SUPPLY AIR SUPPLY AIR DUCT TO SPACE — ELECTRIC HEATER ON DISCHARGE — PROVIDE FULL SIZE SHEET METAL WITH OSA OPENING ON ONE SIDE & FASTEN OSA DUCT TO OPENING ON SHEET METAL AIR HANDLING UNIT — REFRIGERANT AND VAPOR LINES FROM ABOVE ROUTED TO CONDENSER UNIT. REF. DWG. M200 C CONDENSATE DRAIN WITH TRAP Z/�::NEOPRENE ISOLATION PAD C 2"X2"X1 /4" ANGLE WELDED SUPPORT FRAME UNDER UNIT 7 FLOOR SLAB ON 3 SIDES ELEVATION OF FLOOR MOUNTED AHU SYSTEM SCALE: N.T.S MAXIMUM SAG 1/2" PER FOOT OF SUPPORT SPACING FLEX DUCT '-0" METAL STRAP 2" MINIMUM REFRIG.PIPING THRU ROOF JACK. SEAL ALL AROUND WATER TIGHT NOTES: 1). DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL FLEX DUCT SUPPORT DETAIL. INCHES FROM A CONNECTION BEFORE BENDING. NOT TO SCALE 2). SUPPORT SYSTEM MUST NOT DAMAGE DUCT OR CAUSE OUT—OF—ROUND SHAPE. kO5MARKUPS 155UE 8 JSV PER MARKUPS. 8 J5V PER MARKUPS. raw 7"0,1 PERMIT P PEV1510N5 # I DATE I BY 155UE I 107-13-181 NS PER BLG.DEPT.GOMM. HVAC DETAILS KINEHART 55 ASSOCIATES LLC 145 1 PINEHAPT ROAD, SANFOPD, FL 32771 0 L z62 �a Q2 LD2 O0 9Z 00 "•,poi/a�a�% � � .u. iiaiaaiaiai/ � • J 257 — ' ^ u.j 4� tD j �Ra N N W E V w ow i�°t. ri moi°� �'Y3 ��� N`y �o i71 t,�a<- amu =q5 B G8v8nn���' d0 Jr.0 �m0 aimQo ani`^ ft `t�NpErivSoi OK 0ou X190 <Q z �LLi�+� pv N� Ua��j 0 N�> �`�� �IL pn° HU act G -S L°N o�u� u1E 5 WLu 0 oC GW 7= 11WHu �w7 N o. 554 .o S TE F �O' S✓ONA1. , .. � r DRAWN 5Y DATE EDJ 1 02-09-18 GHEGKED by IDATE RMB O5- 2035 FILE NAME 2035-5T R. DWG SHEET M-0.1