Loading...
HomeMy WebLinkAbout419 W 19 St 18-3197; PERMIT & (A)11 I COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 18100006 BUILDING APPLICATION #: 18-10000679 BUILDING PERMIT NUMBER: 18-10000679 I - 11(q DATE: August 10, 2018 'Fa UNIT ADDRESS: 19TH STREET W 413 36-19-30-506-0000-1050 TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: NSP HOLDINGS LLC ADDRESS: 824 1 VIA BONITA SANFORD FL 32771 LAND USE: SINGLE FAMILY RESIDENCE TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES" 413 W 19TH'STREET / SANFORD HEIGHTS SFR FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUETYPEDISTSCHEDRATEUNITSTYPE ROADS-ARTERIALS CO -WIDE ORD Sing16 Family Housing 705.00 1.000 dwl unit 705.00ROADS -COLLECTORS Nl. single Family Housing .00 1.000 dwl unit .00FIRERESCUEN/A LIBRARY C07WIDE ORD . 00 SinEle Family Housing 54.00 1.000 dwl unit 54.00SCHOOSCO:WIDE ORD Single Family Housing 9,000.00 1.000 dwl unit 9,000.00PARKSN/A LAW ENFORCE' N/A '00 DRAINAGE N/A .00 00 AMOUNT DUE 9,75,9-00 PERSONS ARE -ADVISED THAT TRISIS, A STATEMENTCF FEES: DUEVNbER THESEMINOLECOUNTYROAD,-FIRE/RESCUE,, LIBRARY AND/OR:ED.1UCATIONAL ISSUANCE OF A BUILD ING PERMIT'. PERSONS ARE 'ALSO ADVISED THAT ANY RIGHTS:OF THE APPLICANT', OR OWNER, TO APPEAL THE CALCULATION OF ANYOFTHE ABOVRMENTIONEDIMPACT FEES, MUST BE'kXEkCISED BY FILING' A WRITTEN REQUESTWITHIN 45 -CALENDARDAYSOF'THE DATE ABOVEj,BUT NO-tATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FORREVIEW MUST MEET'THE REQUIREMENTS OF THE COUNTY'LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNINGAPPEALS MAY BE PICKED UPi OR REQUESTED, FROM THE BUSINESS OFFICE:' 1101'EAST FIRST STREET, SANFORD FL, 32771; 407-665-73-56. PAYMENT—SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDINGDEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 3'2771 PAYMENT SHOULD BE -BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE TOP LEFT OF'THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT ISSUED WITHIN 6'0 CALENDAR DAYS FROM THE DATE ABOVE 0 , Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County, FL Inst#2018122907 Book:9238 Page:1400; (1 PAGES) RCD: 10/25/2018 10:29:52 AM REC FEE $10.00 THIS INSTRUMENT PREPARED BY: Name: Miller Construction Sery Address: 8241 Via Bonita St. Sanford NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: Parcel ID Number: 36-19-30-506-0000-1050 The undersigned hereby gives notice that Improvement will b6 made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information Is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) 41 W. 19th St. in Sanford, FL LOT 105 SANFORD HEIGHTS PB 2 PG 63 GENERAL DESCRIPTION OF IMPROVEMENT: New Single Family Home OWNER INFORMATION: Name: NSP Holdings LLC Address: 8241 Via Bonita St. in Sanford, FL Fee Simple Title Holder (if other than owner) CONTRACTOR: Name: Miller Construction Services LLC Address: 8241 Via Bonita St. in Sanford, FIL Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(l)(b), Florida Statutes. Name: Address: In addition to himself, Owner Designates To receive a copy of the Lienor's Notice as Provided in Section 713.13(l)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is I year from date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR R ORDING YOUR NOTICE OF COMMENCEMENT. I Uni er pena ies 1111perjury, I d are that I have read the foregoing and that the facts stated In it are true to t best t m k owl go nd 6lief. I — ZA4 lj4ux" IS—mF:s-%nature Lvmer3 Printed NameLFI.r.d 13.i30)(g): 'The omer must sign the notice ofcommencement and no one else may be permitted to sign in Na orherstead.' State of County of L-IAJ A N)dve The foregoing instrument was acknowledged before me this lz-z) day of Oc;r - Z2- 1 by Ltuy . Who Is personally k to me Name of person making statement OR—p-ed—a-11 I If Identill [on produ d: PATRIM CASSERVIK My COMMISSION 0 FF22U69 EXPIRES May 0r. 2()19 ANT INIM - Notary Slgnatuht/ coul J- LCO)RI'DA oLpj-Ty CLE,9K e^% JUL 2 3 2018 om - Puilding & Fire Prevention Division PERMIT APPLICATION Application No. 31qj Documented Construction Value: $46 7-0-iggic'.. O'D W. 19th StreetJobAddress: Historic District: Yes F No Parcel ID: 36-19-30-506-0000-1050 ResidentialFv—(]CommercialF Type of Work: Neww] AdditionFlAlteration F Repair F Demo 11 Change of UseF Move 1:1 Description of Work: New Single Family Construction Plan Review Contact Person: Zachary Miller Phone: 407-222-0692 Fax: 407-264-6284 Title: Owner Email: millerconstruction@cfl.rr.com Property Owner Information Name NSP Holdings LLC Phone: 407-222-0692 Street: 8241 Via Bonita St. City, State Zip- Sanford, FL 32771 Resident of property?: No Contractor Information Name Miller Construction Services LLC Phone: 407-792-3955 Street: 8241 Via Bonita St. City, State Zip: Sanford, FL 32771 Name: Street: City, St, Zip: Bonding Company: Address: Fax: 407-264-6284 State License No.: CBC1251569 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6th Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application REQUMED !NSPECTION' Bpff- IF. 7. Irmspeefloni Descr Footer / Sethack I Electrfe Rough T.U.Q. Remwall Pre-P6wer Final 10 Fbundatfoii / Form Board..'Survey to Slab-fM-mio Sla-b-Ptepour I- SO Lintel / TiO Beath / Fill Down Ceff 3o j Sheathing -L, W- alls- 1 Sheathing -L, Raof Roof Dry hi So I Frame 60 Insulation 1 ough In - Firewall S*cr'ew Pattern brywall / Sheetrock LAo ,co Lath lnspe tion Final Solar Finar Roof . Final Stucc6. $idin. g Bastffation Final Final Utilit, Building - Final Door FinalWindc'mr 1 inal Screen.Room creFinal.. Pool S' en Enclosure. Mobile Honle Building- Final Pre: -Demo Final Demo. j Final Single V.ainiTy Resfdencet Final. Building (Other) RIEWSED.* Jbne 2C[14 Address: Max- 1=2 cdon D sc±2dom Electup Underground Footei [Slab Reel Bond I Electrfe Rough T.U.Q. Pre-P6wer Final min Electric Final I Gas Ro h 1 Gas. Final AVI, Ims MIA EPSOM Max. Imspe6dom DescA2120]m 7jju -mb in U09 , hdergTound J_M Plumbing Sewer 2.0 J'Plumbing Tub, Set 1000 Plumbing Final max Mecham'cal Rough Mech="cal. Final min 16RIX Imspectiom Descriodonn 71 Gas Unaerground I Gas Ro h 1 Gas. Final NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the pen -nit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual cohstruction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning, gnature of 0 ejUrg—ent Date ignature ofContr c r gen Date nt Owner/Agent's Name zSignature of Notary -State of Florida Date PATRWJA CASSERVIK My COMMISSION III FF2284% EP ftl?'-A%&,nOwn - s JW6? erson 168wn o Me or Pro Print Contractor/Agent's Name S ignatur fFlorida Date PA gA CASSEtVK My COMMISSION 0 FF2284W EXPIRES May 07. 201914i, Fbr , Serme.car Contracto /Agent is ' ersona y no n to Me or ProducedlD_ TypeoflD BELOW IS FOR OFFICE USE ONLY Permits Required: Building R Electrical Z Mechanical [R PlumbingE] Gas[-] Roof [] Construction Type: lq9.7 Occupancy Use: Flood Zone: X -5 -CE A: tkut p Total Sq Ft of Bldg: 20 Cl Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps I so Plumbing - # of Fixtures. Fire Sprinkler Permit: YesEl No S] # of Heads APPROVALS: ZONING: COMMENTS: UTILITIES: ENGINEERING:VA—t(- FIRE: fs Fire Alarm Permit: Yes [] No F] WASTE WATER: BUILDING: 'W- (Q-0Q- Revise& January 1, 2018 Permit Application CITY 1011` Jui FIREDEPARTMEW Building & Fire Prevention Division PERMITAPPLICATION A . p - plication No. 319 Documented Construction Value:$ 1601000 q i-; Job Address: W. 1 9th Street Historic District: Yes[] Now] Parcel ID: 36-19-30-506-0000-1050 ResidentiaIFZ CommercialEl Type of Work: NewW] AdditionFlAlteration E] Repair 0 Demo 1-1 Change of UseE] Move 1:1 Description of Work: New Single Family Construction Zachary MillerPlanReviewContactPerson. Phone: 407-222-0692 Fax: 407-264-6284 Name NSP Holdings LLC Street: 8241 Via Bonita St. Title: Owner Email: millerconstruction@cfl.rr.com Property Owner Information Phone: 407-222-0692 Resident of property?: No City, State Zip: Sanford, FL 32771 Contractor Information Name Miller Construction Services LLC Phone: 407-792-3955 Street: 8241 Via Bonita St. Fax: 407-264-6284 City, State Zip: Sanford, FL 32771 State License No.: CBC1251569 Architect/Engineer Information Name: Phone: Street: Fax: City, St Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS. TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code Revised: January 1, 2018 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual cofistruction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. gnatureofO eVrg7F.—t Date igna eofCon co gent Date Pnl,.Ccr/Agent's Name Print Contractor/Agent's Name Signature ofNotary-State ofFlorida Date S ignatur""IQ of Florida Date PA A 'SERVW FF22 r9SSCN S W y 07. 1 M "YE PATWIA CASSERVUC Y COMMISSION # FF228469PATRWAACAWERVOC EXPIRES May 07.2019MYCOMMISSION # FF228469 1A, 34n -C— F Swvwe..wr ES 7. A18, r t is V so v P6? errOw Y wn o Me or Contractor/Aggent is Persona y nown to Me or Pro, Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building[] Electrical[] MechanicaIE] PlurnbingF] GasE] Roof[] Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: YesE] NoF1 # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures, Fire Alarm Permit: YesF1 No [] UTILITIES: Ah 1- 7-Z7 WASTEWATER: FIRE: BUILDING: Revised: January 1, 2018 Permit Application Revision 0 Response to Commentsla OCT 0 h 2018 Project Address: Contact: Ph: YO 7- 6 2 - Fax: Email: Y14tWe(COA C -Q. fr. (00-1 Trades encompassed in revision: 3 Building El Plumbing El Electrical IT Mechanical El Life Safety El Waste Water Department El Utilities El Waste Water El Planning 0 Engineering El Fire Prevention 0 Building City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov General description of revision: Ilef-V Cq (C .5. ROUTING INFORMATION Approvals TO 0 1. Kg PLAN REVIEW COMMENTS Application Number: 18-3197 Date: 09/28/2018 Project Description: New SFR Contact Name: Zachary Miller Job Address: 413 W 19" Street Contact Email: millerconstruction(&cfl.rr.com This is a general overview for code compliance in accordance with the minimum plan review required by the Florida Building Code. It is not a complete detailed review. The comments noted in this review must be addressed before the plans can be approved. Changes to plans shall be submitted on the same size format as the original submittal — changes in letter form are not permitted. All references to FBC Chapter I are as amended by City of Sanford ordinance viewable on our website at www.sanfordfl.jzov. Provide two copies of affected plan sheets andlor supplemental information as requested. Permit submittals will not be accepted without two copies. COMMENTS: 1. Two (2) copies of a Truss Layout from the truss manufacturer are required to be submitted for review FBC 107 2. The Energy Calculations need to be printed out "portrait" orientation and I sheet per page for legibility. FBC 107 3. The Energy Calculations specify an "unvented" attic/roof. The plans are not designed for an unvented attic. Please revise FBC 107 4. The Energy Calculations specify R-20 insulation for the Attic while the plans specify R-30. Please revise the calculations to R-30 insulation for the attic space FBC 107 5. The Energy Calculations specify R4.1 for the CMU walls while the plans specify R4.2. Please revise as necessary FBC 107 6. Detail I/A2.1 "Typical Wall Detail" shows a sternwall foundation. The foundation page specifies a mono foundation. Please revise as necessary. FBC 107 7. The Electric plan page is required to show the smoke/carbon detectors as required by FBCR R314 & R315 FBC 107 8. A (GFCl) receptacle is required at the exterior Front Entry Porch. Please revise Sheet E. I to show this FBC 107 9. Plan page A2.2 Truss Layout is missing. Please provide an accurate truss layout on the plans, including truss locations and truss ids that match the Truss Layout from the truss manufacturer. All hold-downs shall be specified on the truss plan page. FBC 107 10. The Product Approval package is incomplete. Please provide two (2) copies of a corrected Specification Sheet, Florida Product Approval and corresponding installation instructions for the following products: BE 7 SirWIe hung windows (double hung approvals submitted) Fixed windows (none provided) Shingles (starter strip approvals submitted) Mullions (none provided) FBC 107 Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal ordinances of this jurisdiction. Office meetings with the plans examiner to discuss comments will require an appointment, arranged by phone or email prior to arrivaL Respectfully, Steve Florey, CBO Deputy Building Official 2- PLANNING & DEVELOPMENT SERVICES DEPARTMENT Flood Zone Determination Request Form Name: Zachary Miller Firm: Miller Construction Services LLC Address: 8241 Via Bonita St City: Sanford State: FL Zip Code: 32771 Phone: 407-222-0692 Fax- 407-264-6284 Email: millerconstructionC&O.rr.corn Property Address: 413 W. 19th Street Property Owner: NSP Holdings LLC Parcel identification Number: 36-19-30-506-0000-1050 Phone Number: 407-222-0692 Email: millerconstructionC&cfl.rr.com The reason for the flood plain determination is: W-1 New structure Existing Structure (pre -2007 FIRM adoption) F Expansion/Addition Existing Structure (post 2007 FIRM adoption) Pre 2007 FIRM adoption = finished floor elevation 12" above BFE Post 2007 FIRM adoption finished floor elevation 24" above BFE (Ordinance 4360) J;'n C lAL IFT lU-Sg1-r§ - _j NL -Y, Flood Zone: X Base Flood Elevation: N/A Datum: N/A FIRM Panel Number: 120294 0070 F Map Date: Sept. 28, 2007 The referenced Flood Insurance Rate Map indicates the following: F-1 The parcel is in the: F-1 floodplain El floodway F-1 A portion of the parcel is in the: 0 floodplain F-1 floodway The parcel is not in the: FE -1 floodplain E]floodway The structure is in the: 0 floodplain 0 floodway El The structure is not in the: E] floodplain 0 floodway If the subject property is determined to be flood zone 'A', the best available information used to determine the base flood elevation is: BP# 18-3197 Reviewed by: Michael Cash, CFM Date: September 17, 2018 5/30/2018 CFA Parcel Information SCPA Parcel View: 36-19-30-506-0000-1070 Pro e Record Card Parcel: 36-19-30-506-0000-1070 Property Address: W 19TH ST SANFORD, FL 32771 Parcel 36-19-30-506-0000-1070 Owner(s) NSP HOLDINGS LLC Property Address W 19TH ST SANFORD, FL 32771 Mailing 8241 VIA BONITA SANFORD, FL 32771 - Subdivision Name SANFORD HEIGHTS Tax District SI-SANFORD DOR Use Code 00 -VACANT RESIDENTIAL 1-11.11.1 . .............................................................. Value Summary Description I* ********* 2018 Working 2017 C rti ied Values Values Page Amount Valuation Method Cost/Market Cost/Market 0 1--l—I . . . . .. . ............ - ............. Number of Buildings 0 0 08911 Depreciated Bldg Value Yes Depreciated EXFT Value 1-11.11.1 . .............................................................. Land Value (Market) 16,995 $15,579 L a n d Va I u e Ag QUIT CLAIM DEED Just/Market Value 16,995 75 9 1014 Portability Adj No Vacant Save Our Homes Adj 0 $0 04243 Amendment 1 Adj 0 $1,246 No P&G Adj 0 $0 9/1/1998 Assessed Value 16,995 $14,333 Tax Amount without SOH: $281.10 2017 Tax Bill Aniount $281.10 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments Description Date Page Amount FRONT FOOT & DEPTH Qualified 0 WARRANTY DEED 5/1/2017 08911 0372 30,000 Yes Vacant 1-11.11.1 . .............................................................. I — --- 1 .. ... . . ...... . ...................... QUIT CLAIM DEED 1/1/2004 05173 1014 100 No Vacant QUIT CLAIM DEED 12/1/2001 04243 1106 100 No c n QUIT CLAIM DEED 9/1/1998 03512 1526 100 No 1 vacant WARRANTY DEED 1/1/1977 01132 100 No Land Method Frontage 5500 Depth Land FRONT FOOT & DEPTH U nits Un,t. 154.00 0 Pnc-e Val.. 300.00 11-1--- .............................. ..... . .......... . .................... ........ . .......................... .................. Building Information http://parr-eidetail.sepafl.org/PareelDetailInfo.aspx?PlD=361 93050600001070 1/2 0 CD Fnd. Re Cap.PSM 33 49.30 1/2 IRC PSM 338 F.1 0 to Lot 104 1.8' 3 4998 518" 1 RC 47 Fnd. 518* Reba Cap ZB 447 0.21'North 0.79'East 50'Right-of-Way - Asphalt Road) W. 19th Street (Field) T3 - - - - - - - - I H_ i -9- -h-1 -St F6 -et _(P I a 1-) 104ill).3911 SBM # 2 7 Miami Curb 47.694-, A#1ssm 8 50.00-(P) 50.00'(P) 11 "BB" 48557 49.300 255.00'(P) 1 IRC PSM 2259N90*00'00" E 50.00'(M) N 90-00-00" E 50.00'(M a 90*00'00* E 251.63'(MUCALCIF r 0 Set 1/1' Reb; Fnd. '/'Reber6 3 S M.' Rebar 48.689 18- 8 1/4 IP Cap "LB 76 48.796 C p 'LB 7623' cr) 7 0 10 49.300-F 114 IP 13 Fnd. 1W Iron Pipe 2 CALC 2 CA C Set %Rebar 25 Cap 'LS 7623' No Identilization) 'A 0.37South 51.330 51.330 106 Bldg env IF, 2 9 51.330 3.91'West 105 Bldg env P.01 5.Y 0 7.2'1107 Bldo env 7.8' Ot 0.00, OB' 000`0 0 0-00. 2222 2626 3 51 33051330 1.33051330 51.330 105 Bldg'anv05Idogan" d anI v106Bdgenv10 107 Bldg env c%i Y6B R IliEk 'OTx I Nrto U) U LLI P 5.01 L.. N posed FFE\=51' ProposedPrpoad FFE=51. sedroposed FFE=51.3 cr) 40.' 0._ 0., 0- C,4N 0 7.5. s.tf 24 28 VO Y K33 51.330 23 4 Lr. 51.330 27 51.330 CD. 105 Bldg env 51.330 .0 106 Bldg env 51.330- CD 107 Bldg env z 105 Bldg env ILL 106 Bldg env 31 x U) 51.330J 164 49.886 107 Bldg env TR Parcel 1 4q Parcel 2 Parcel 3 Lot 105 Lot 106 Lot 107 5 stat 7 15 14 5 12.2' 49300 49.300 r C LC Reber a 111a Reber C; 01 VP ap.LB 7623. Caj LB7623" vv,V 4 Z 1.5 Site Benchmark Information - Set Nall & Disk LB# 7623 In Asphalt. Elevation: 47.69' Set Nall & Disk LB# 7623 in AsphalL Elevation: 48.391 Benchniark Information- FDoT GPS Network Florida Department of Transportation GPS Network N.Trip Base 10 - Sanf Elevations are based upon NAVD 88 Datum) 0 Fnd. '/'Reber Cap "PSM 3382" 3 rlheast 48.689 Comer of Lot I 11 1/4 IP Site Benchmark Information - Set Nall & Disk LB# 7623 In Asphalt. Elevation: 47.69' Set Nall & Disk LB# 7623 in AsphalL Elevation: 48.391 Benchniark Information- FDoT GPS Network Florida Department of Transportation GPS Network N.Trip Base 10 - Sanf Elevations are based upon NAVD 88 Datum) Set W 50.00, < R-a 5061foo 0'00'(M 14' Platted Alleywaycap13--7 S 90,00100 CD10' Crushed Asphalt. CID 49.300 W CALZ 3 CD S :3 50,848 TR 1861n Lot 151 Graphic Scale Lot 154 Lot 153 Lot 162 4 3b'. 60' Scale: 1"=30' W, 0 ft n 06 0 cr) M U 13 N =3 49.300 CA C Set %Rebar j Cap 'LS 7623' D Set W 50.00, < R-a 5061foo 0'00'(M 14' Platted Alleywaycap13--7 S 90,00100 CD10' Crushed Asphalt. CID 49.300 W CALZ 3 CD S :3 50,848 TR 1861n Lot 151 Graphic Scale Lot 154 Lot 153 Lot 162 4 3b'. 60' Scale: 1"=30' W, 0 ft n 06 PLANNING AND DEVELOPMENT SERVICEs DEPARTMENT WVVW.SANFORDFL.GOV MAILING ADDRESS April'19, 2017 CITY OF SANFORD POST OFFICE Box 1788 SANFORD, FLORIDA 32772-1788 Mr. Zach Miller 8241 Via Bonita Street PHYSICAL ADDRESS Sanford, FL 32771 CITY HALL 300 NORTH PARK AvENUE SANFORD, FLORIDA 32771-1244 RE: Variance request for 411 and 413 W. 19'11 Street Parcel Numbers: 36-19-30-506-0000-1050 and 36-19-30-506-0000-10,60 TELEPHONE Dear Mr. Miller: 407.688.5140 FACSIMILE On,March 28, 2017, the Administrative Official, pursuant a recommendation made by the 407.688.5141 Development. Review Team, approved the Variance request for two variances on adjacent 0 lot to reduce the minimum area and dimension requirements to lotof record standards in order to subdivide the parcel into two lots 105 and 106 at 411 and 413 W. 19"' Street CITY COMMISSION subject to the following condition: JEFF TRIPLETT MAYOR I . The proposed single family homes shall utilize stem wall construction due to the reduced setbacks and minimum distance from adjacent property lines. ARTWOODRUFF 2. The proposed single family homes shall meet the infill lot gradingDISTRICT1 requirements (aitAched); all appropriate.spot elevations and grading shall be DR. VELIAA H. WILLIAMS included on the site plan for review. DISTRIcT2 3. All existing structures shall be demolished prior to construction. 4. A canopy tree shall be, provided in the front yard per Schedule J. In addition, PATRICK AUSTINI if any -existing trees are to be removed an arbor permit may be required. DI STRICT 3 5. A minimum 9' wide driveway meeting the requirements of Schedule N shall PAM MARANY be provided and a driveway permit must be obtained. DISTRICT4 0 Be on notice that, appeals of theabove decision may be made to the City Commission by any person aggrieved or by any officer, board or agency of the City including the City CITY MANAGER NORTON N. BONAPARTE, JR. Commission within thirty (30) calendar days of the Administrative Official's action. The applicant shall be required to withhold all action on the property until the 3 1 st day past the date noted above. If you have any questions please call this office. Respectfully, CITY OF SANFPWD Eileen Hinson, AICP Development Services Manager EH/jg City of Sanford Development Review Team Variance - Staff Recommendations Legal Description of the Property: F5]--oF6] I o I o I o 1 1 o 5 Fol Address of Property: 411 and 419 W 19th Street — Zoning District: SR -1A Name and Address of Owner as shown in the Public Records of Seminole County, Florida: Robert C. and Elizabeth J. Mason, 193 Lake Geneva Road Geneva, FL 32732 Application Submitted By: Zach Miller - Miller Construction Address 8241 Via Bonita Street Sanford, Florida 32771 Phone: 407.222.0692 Fax: 407.264.6284 E -Mail: Millerconstruction@cfl.rr.com Standards for Consideration for Variances. Before any variance may be granted, the Planning and Zoning Commission or Administrative Official shall find that the variance would relieve a practical difficulty or undue hardship caused by a strict application of the regulations provided that the variance is occasioned by: Special conditions and circumstances exist which are peculiar to the land, structure or building involved and which are not applicable to other lands, structures or buildings in the same district. The literal interpretation ofthe provisions ofthe land development regulations would deprive the applicant ofrights commonly enjoyed by otherproperties in the same district under the terms ofthe land development regulations. The special conditions and circumstances do not resultftom the actions ofthe applicant. Granting the variance will not confer on the applicant any special privilege that is denied by the land development regulations to other lands, structures, or buildings in the same district. The reasons setforth in the applicationjustify granting the variance, and that the variance is the minimum variance that will make possible the reasonable use ofthe land, building, or structure. The granting ofthe variance will be in harmony with the generalpurpose and intent ofthe land development regulations and will not be injurious to the neighborhood, or otherwise detrimental to the public we6rare. Variances Requested: consider two variances on adjacent lots to reduce the minimum area and dimension requirements to lot of record standards in order to subdivide the parcel into two lots at 411 and 413 W. 19th Street. Does this Request meet the Standards for Consideration? 51 Yes El No Site Specific Conditions: Per Schedule L, Nonconforming Lots of the City of Sanford Land Development Regulations lot of records standards can be applied to existing, unimproved parcels of records in the residential zoning districts includin)z the SR- I zoning. The applicant is requesting to subdivide the parcel into the original lots of record in order to construct two sinjzle familv homes; the applicant must apply for a variance to utilize lot ofrecord standards. Staff Recommendations: Staff recommends to approve the variance request to reduce the minimum area and dimension requirements to lot of record standards subject to the following conditions: 1. The proposed single family homes shall utilize stem wall construction due to the reduced setbacks and minimum distance from adjacent property lines. 2. The proposed single family homes shall meet the infill lot grading requirements (attached); all appropriate spot elevations and grading shall be included on the site plan for review. 3. All existing structures shall be demolished prior to construction. 4. A canopy tree shall be provided in the front yard per Schedule J. In addition, if any existing trees are to be removed an arbor permit may be required. 5. A minimum 9' wide driveway meeting the requirements of Schedule N shall be provided and a driveway permit must be obtained. N ...... Ve N - WXX0" NJX, Don ed X i XAdVeOffibl' K;", XX" A00 ........... ppro'. .......... -:%'V' X X%x ye!,,_emos\oAT N 46'66'; '_11JL,,A41SW,'1 W4 . M Of X44'N City of Sanford Development Review Team 1857Y%7i9_' 4kIi Variance - Staff Recommendations The Development Review Team (DRT) held a Public Meeting at 9 AM on March 28, 2017 to consider two variances on adjacent lots to reduce the minimum area and dimension requirements to lot of record standards in order to subdivide the parcel into two lots at 411 and 413 W. 191h Street. Although the proposed split is to return to the lots of record, both have non -conforming dimensions. As part of the evaluation, the standards for consideration were reviewed. Special conditions and circumstances exist which are peculiar to the land, structure or building involved and which are not applicable to other lands, structures or buildings in the same district. Per Schedule L, Nonconforming Lots of the City of Sanford Land Development Regulations lot of records standards can be applied to existing, unimprovedparcels of records in the residential zoning districts including the SR -IA zoning. The applicant is requesting to subdivide the parcel into the original lots of record in. order to construct two singlefamily homes; the applicant must applyfor a variance to utilize lot of record standards. The literal interpretation of the provisions of the land development regulations would deprive the applicant of rights commonly enjoyed by other properties in the same district under the terms of the land development regulations. The owner would like to subdivide the property to the original platted lots of record to construct two single family homes. The subdivision will result in two lots that do not meet minimum standards designatedfor the SR-lA zoning classification. The special conditions and circumstances do not result from the actions of the applicant. The parcel is made up of two platted lots of record. The applicant is requesting the variance in order to construct two new homes utilizing the existing nonconforming lot size andparcel ofrecord standards. Granting the variance will not confer on the applicant any special privilege that is denied by the land development regulations to other lands, structures, or buildings in the same district. Other properties in the area have been granted variances to utilize the parcel of record standards or are currently vacant and can utilize the standards by right. The reasons set forth in the application justify granting the variance, and that the variance is the minimum variance that will make possible the reasonable use of the land, building, or structure. The applicant has submitted a site plan showing that a proposed single family residence can be constructed utilizing the reduced standards on each lot. The applicant could not reasonably build a single family home on this lot without utilizing the lot of record setbacks. The granting of the variance will be in harmony with the general purpose and intent of the land development regulations and will not be injurious to the neighborhood, or otherwise detrimental to the public welfare. Based on existing neighborhood conditions, the structure as proposed will not be injurious to the existing surrounding improvements or to the public we fare. After deliberation of the standards a motion was made and an action taken as follows: Richard Blake made a motion to approve the variance request to reduce the minimum area and dimension requirements to lot of record standards subject to the following conditions: I . The proposed single family homes shall utilize stem wall construction due to the reduced setbacks and minimum distance from adjacent property lines. , 2. The proposed single family homes shall meet the infill lot grading requirements (attached); all appropriate spot elevations and grading shall be included on the site plan for review. 3. All existing structures shall be demolished prior to construction. 4. A canopy tree shall be provided in the front yard per Schedule J. In addition, if any existing trees are to be removed an arbor permit may be required. 5. A minimum 9' wide driveway meeting the requirements of Schedule N shall be provided and a driveway permit must be obtained. A Second was made by Jeff Davis. Discussion: There was no additional discussion. Those in favor: Mike Cash, Tim Robles, John Hamel, Jeff Davis, Richard Blake, Sabreena Colbert Motion approved 6 to 0. No public was present in favor or opposed. CITY Or SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Applic6ation Nio: COIIStRIC6011 VIIIUe: Job Addi-ess: 413 qtt, P.a i, c o I ti): Lsod to T N-po of Wo I, k-: Now ["Addirion A Ire i-ation Histoi-ic Disti-ict: )'cj Residn'tial 11- 1-, colllrnc.-ckal Demo 71 Change of t's. I , 0 -move F Man Reviow Cozitoct pel-son: 11 h o [1,: sn-eet Fax: Ertl a i I: Piropeirty Infomn---tion M,I ov h6yuc Pilone.. Ci.,. Sto,: zip: Ccntractcr Ticle: r" ,- s i c! t, t (, f p 1 - 0 p c-;- t-.\ - " : L s t :-e -1-t j ')k F.1 X: ik h-li-c-unati-on A c! ,! i -c ph') F .1-1 x E - .-I:t It 0 c)"\N[ 11,': YOUP I .\IL 1. i E T () I I- C icf-. v o I: i,, PAVING T\ I (-'E 1 0 P I ) 1 Pi 0 1, T S TO 0 L'i-1. I' P, () P E.- t""T '- A NOTICL 01. CO'\IMENCT IENT E, cc):, 11 I- ilo-FED ON .10i; TIT 1!.'FOPE Tt.! H!"S-1 INS -PEO ION. IF YOU IM 1. xf) I A' A-1-1*0,,.NEV !E!-Oi E R N U, T I L J, 1 CIA: f! jj: r NOTICE: [n additiop tc) ih PCOk- FZCT.-d (If Uhl; a v 1, dI tr;,C.Es, SIZIC or al cce; t i 5 \-; -i flica 6"; (""1! 1 \ i I I 0 f lh- ; ,;-Lj P or PC mn; 1 ; , of Fiold, Li r, FS 71 Th -_ C i o 1, fxd' L',,pui 5 r j ;:1! o I, In is ch:!.-o and v ill L)c valu.- of Lh-: i..-jb -W L)f Val_ v;m an,hod; to vo!—- P,-.,--,: v, is 4, 0\\-:\'I- WS A FF1 DAVIT: I urti fy Olat all o f tllo r()j.Q ()i 1 . L . I , ill 1`0 I'll' 'a CiOil iS RCCUl".1te ',!Tld be dolle it) Complionce with all apphc llhle 1.-IN\S il (I ,.a -_i n z 'S D T 1 D Q Z AMY R. MORRIS Notary Public -State of Floridi3 B.rded Commission -' GG 185209 a, 0MyComm. Expir`eshlars throuqh Natio nal 119,1111' Assn, at 91 yy BELOW JS FOR OFFICE USE UN -LY p Elr i". - ., d S l 1-1 (-,* f E', [,A 71 __ Mi. -I. I' I c. f I I V A I z C) F i 1-7- NT. T 1* 1 '1 i T J-1 FIRE INSPECTIONS CITY OF SANFORD 407.S62.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Application Number . . . . . 18-00003197 Date 10/29/18 Application pin number . . . 69993S Revision number . . . . . . . 1 Property Address . . . . . . 413 W 19TH ST Parcel Number . . 36.19.30.506-0000-1050 Application type description NEW SINGLE FAMILY HOME - DETACHED Subdivision Name . . . . . . SANFORD HEIGHTS Property Zoning . . . . . . . SINGLE FAMILY Application valuation . . . . 209996 Application desc need noc Owner Contractor NSP HOLDINGS LLC MILLER CONSTRUCTION SERVICES L 8241 VIA BONITA ST SANFORD FL 32771 407) 792-395S Structure Information 000 000 ---------------------- Construction Type . . . . . VB Occupancy Type . . . . . . RESIDENTIAL USE GROUP Flood Zone . . . . . . . . NONE Other struct info . . . . . ELEC - # AMPS 150.00 PLUMBING FIXTURES 15.00 NUMBER OF STORIES 1.00 SQUARE FOOTAGE 2017.00 Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Phone Access Code 1084789 Permit pin number 1084789 Sub Contractor . STRADA ELECTRIC & SECURITY Permit Fee . . . . 60.00 Issue Date . . . . 10/29/18 Valuation . . . 6200 Expiration Date . . 4/27/19 Qty Unit Charge Per Extension 150.00 .4000 AMP ELECTRICAL - NEW CONSTRUCTION 60.00 Special Notes and Comments All projects within the City shall use WastePro for debris removal. Please contact WastePro at 407.774.0800. Normal hours for inspections are from 7:30 through 4:30 Monday through Thursday. Please be aware you must contact the Building official to schedule a Friday or after hours inspection. This is required since not every inspector is licensed to do every type inspection. Communication is the key, so please contact the Building official if you have any questions at 407.688.5058 or at dave.aldrich@sanfordfl.gov Water im(pact fee $1343.00 Sewer impact fee $3025.00 Other Fees . . . . . . . . . 01-APPLCTN FEE -ELECTRIC 25.00 01-APPLCTN FEE -BUILDING 25.00 01 -BLDG PLAN REVIEW 855.00 02 -CURB CUT/DRIVE - SIF 40.00 01 -FIRE IMP -RS 9-2017 383.81 FAILURE TO COMPLY WITH MECHANIC'S LEIN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. NOTE: ALL FEES MUST BE PAID PRIOR TO C.O. BEING ISSUED. NOTE: PLEASE BE ADVISED ALL PERMITS MUST BE INSPECTED. FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Page 3 Application Number . . . . . 18-00003197 Date 10/29/18 Revision number . . . . . . . 1 Property Address . . . . . . 413 W 19TH ST Parcel Number . . 36.19.30.506-0000-1050 Application description . . . NEW SINGLE FAMILY HOME - DETACHED Subdivision Name . . . . . . SANFORD HEIGHTS Property Zoning . . . . . . . SINGLE FAMILY Permit . . . . . . ELECTRICAL PERMIT Additional desc . . Phone Access Code 1084789 Permit pin number 1084789 Required Inspections Phone Insp Seq Insp# Code Description Initials Date 10 221 SSB FOOTER/SLAB STEEL BOND 20 212 EL01 ELEC ROUGH 20-1000 216 TUGP TEMPORARY UNDERGROUND POWER 1000 213 EL02 ELECTRIC FINAL CITY OF PERMIT APPLICATIONSkNFORD BUILDING DIVISION Application No: (q 7 Documented Construction Value: $ 0 C Job Address: Historic District: Yes 11 No Parcel ID: Residential [I CommercialP Type of Work: New ErAdditionEl AlterationF] RepairEl DemoEl Change of UseEl MoveEl Description of Work: f"' tlll't 6 1;_- 53 Plan Review Contact Person: Phone: Fax: Name Street: City, State Zip: - Property Owner Information Phone: Title: Resident of property?: Contractor Information Name L z t_., d o,, (2K e__ (h, Phone: _`f 0 7 Street: Fax: C-/ 07 C2 f I City,StateZip: 6ft6l_46 9-0 State License No.: !f C 19 1 6 .2- Name: Street: city, St, Zip: Bonding Company: Address: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in,this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that maybe found in i1he public records of this county, and there may be additional permits required from other governmental entities such as water man gement districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Signature of Contractor/Agent Date Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID - Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building 0 Electrical 11 Mechanical [I Plumbing F1 GasEl Roof El Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: YesE]NoF] # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes E] No E] WASTE WATER: BUILDING: n OCT 3 0 2018P CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No:. N Gil Documented Construction Value:$ KINO -ou" Job Address: L Historic District: Yes D NoEl Parcel ID: Description of Work: Plan Review Contact Phone: Name Street: City, State Zip: Zoning: Title: Fax: E-mail: Property Owner Information Phone: Resident of property? : ntractor Information Name 10 (A A Phone: Street- MAO 1P, Fax: IV- ow- ol/o City, State Zip: Nalb, State License No.: frugaa Architect/Engineer Information Name: Street: City, St, Zip: Bonding Company: Address: Building Permit'IZ Square Footage: — Phone: Fax: E-mail: Mortgage Lender: Address: PERMIT INFORMATION Construction Type: No. of Stories: No. of Dwelling Units: Flood Zone: o. Electrical 0 Plumbing 2( New Service – No. of AMPS: New Construction - No. of Fixtures: Mechanical 0 (Duct layout required for new systems) Fire Sprinkler/Alarm 0 No. of heads: Applic tion is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee. A copy of the executed contract is required in order to calculate a plan review charge. If the -.executed contract is not submitted, we reserve the right to calculate the plan review fee based on past permit activity levels. Should calculated charges exceed the documented construction value when the executed contract is submitted, credit will be applied to your permit fees when the permit is released. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is ..Personally Known to Me or Produced ID Type of ID APPROVALS: ZONING: UTILITIES: ENGINEERING: FIRE: COMMENTS: Rev 11.08 I Si atureofContractor/Agent Dhte Signature of Notar+ale of Oi6ridan FlonClaStateof 1 ry b1i r ofrFlorida N-t-rY State Masey Rose Barger 4OnGG23118 y rr mission GG 231184 M 7'12212022 My 0E.Pir 07122/2022r Contractor/Agent is Y Personally Known to Me or Produced ID - Type of ID WASTE WATER: BUILDING: Tropical Plumbing & Septic, Inc. 19468 East Colonial Drive Orlando, FL 32820 P 407-568-0111 F 407-568-0119 CFC1425621 TO Miller Construction 8241 Vin Bonita Sanford, FL 32771 ForAll Your Plumbing Needs QUOTE www3ropicalPlumbing.cc DATI;' October 23, 2018 EXPIRATION 1/21/19 fli7 - - .- I "; BY, ]' ' ' - '__' _, ': , -,."6ATE -P s USED,-" S -;_:,WRI EJOON -PAYMENT, TERMPREP Lynette 19th Street, Cascadia House 4/26/2018 This q,uote is per the plans we received from your compan Bath I I Toilet Gerber Elongated Standard Height White I Lav Sink Gerber China Drop In White 19" Round I Faucet Moen Chateau Chrome 4" 1 Shower Pre -Sloped w/pan I Valve Moen Posi Ternp I Trim Moen Chateau Chrome Bath 2 1 Toilet Gerber Elongated Standard Height White I Lav Sink Gerber China Drop In White 19" Round I Faucet Moen Chateau Chrome 4" 1 Tub/Shower ProFlo Steel RH/LH White I Valve Moen Posi Temp I Trim Moen Chateau Chrome yjtchen I Sink ProFlo 50/50 SS Drop In I Faucet Moen Integra w/Pull Out Sprayer SRS I Disposal Badger 5, 1/2 HP I Dishwasher connection I Ice Maker Box w/ loop under sink Laundry I Washing Machine Box Water Heater 40 gallon electric, A.0. Smith/State Hose Bibs - 2 AC Chases - 1 Sewer & water within 50ft of Building. Sewer taps not over 4' Deep. All water lines are CPVC. All sanitary sewer lines are PVC. Add water hammer arresters as per code. Roof flashings/lead boots are not included. Water is required for all leak testing and inspections. Complete Plumbing Total $8,600.00 I " Backflow preventer if required $525.00 Multi valve shower set up may require 80 psi for fixtures to function properly $2,500.00 In-line booster pump if needed, supplied & installed, power not included Payment past 30 days Tropical Plumbing Ft Septic, Inc. has the right to charge thereafter a service charge of 1.5% of unpaid balance per month. (18% per annum) plus all f I'W r1on including attomey's fees if incurred. TropicalCos" of P warranty froPlumbingEtSeptic, Inc. gives a one year labor pi(5date7f c mpletion. To accept this quotation, sign here and retum: RECORD COPY 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cascadia Builder Name: Miller Construction Services 13 U7/4,0> Street: 413 19th Street Permit Office: City of Sanford City, State, Zip: Sanford , FL , Permit Number: 151() 8-- 3 19 7 0% Owner: Miller Construction Services Jurisdiction: 0 Design Location: FL, Orlando County: Seminole (Florida Climate Zone 2 7-ME I New construction or existing New (From Plans) 9. Wall Types (1304.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1116.00 ft2 b. Frame - Wood, Adjacent R=13.0 188.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1495.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1495.00 ft2 6. Conditioned floor area above grade (ft2) 1495 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft' 7. Windows(203.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 299 a. U -Factor: Dbl, U=0.34 203.33 ft2 SHGC: SHGC=0.29 b. U -Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 23.2 SEER:14.00 c. U -Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U -Factor: N/A ft2 a. Electric Heat Pump 23.2 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.290 14. Hot water systems a. Electric Cap: 50 gallons 8. FloorTypes (1495.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1495.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.136 Total Proposed Modified Loads: 46.31 PASSTotalBaselineLoads: 46.38 1 hereby certify that the plans and specifications covered by Review of the plans and Sr4 this calculation are in compliance with the Florida Energy specifications covered by this Vf14E Q - Code. Digitally signed by Luis Morales calculation indicates compliance Luis Morzdes Date: 2018.06.29 09:48:20 -04'00' with the Florida Energy Code. 1-4 lhw PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this buildinq, as d s in compliance Florida Statutes. 001) with the Florida En rg de WE OWNER/AGENT' BUILDING OFFICIAL: DA1 E. DATE: Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 6/29/2018 9:46 AM EnergyGauge) USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 6/29/2018 9:46 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 4 PROJECT Title: Building Type: Owner Name: of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Cascadia User Miller Construction Services 1 Miller Construction Services City of Sanford 691500 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 1495 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 413 19th Street County: Seminole City, State, Zip: Sanford , FL , CLIMATE V Design Location TMY Site Design Temp 97.5% 2.5% Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Orlando FL—ORLANDO—INTL—AR 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Blockl 1495 11960 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1495 11960 Yes 4 3 1 Yes Yes Yes FLOORS V# Floor Type Space Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 139.5 ft 1495 ft2 0.29 0 0.71 ROOF V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 1541 ft' 0 ft2 Dark 0.6 N 0.6 No 20 14 ATTIC V# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1495 ft2 N N CEILING Ceiling Type Space R -Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0.01 Blown 1495 ft2 0.1 Wood 6/29/2018 9:46 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 6/29/2018 9:46 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 3 of 4 WALLS 0 Adjacent m t To-Wall-Typie Space Cavity Width Height R=Value-F-t--In Ft-ln-----4-rea-R=Value-Fraction-Absor---Gj-ade%- Sheathing Framing Solar Below 1 2 3 4 5 N W S E Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Garage Frame - Wood Main 4.1 40 0 8 4.1 38 6 8 4.1 19 6 8 4.1 41 6 8 13 23 6 8 0 320.0 ft2 0 308.0 ft2 0 156.0 ft2 0 332.0 ft2 0 188.0 ft2 0 0 0.6 0 0 0.6 0 0 0.6 0 0 0.6 0 0.25 0.6 0 0 0 0 0u DOORS V Ornt DoorType Space Storms U -Value Ft Width Height In Ft In Areal 1 2 E Insulated Main Wood Main None None 6 3 6 3 6 8 6 8 20 ft2 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Ornt ID Frame Panes NFRC U -Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 N 1 Metal Low -E Double Yes N 1 Metal Low -E Double Yes W 2 Metal Low -E Double Yes S 3 Metal Low -E Double Yes E 4 Metal Low -E Double Yes 0.34 0.29 N 0.34 0.29 N 0.34 0.29 N 0.34 0.29 N 0.34 0.29 N 23.3 ft' 1 ft 0 in 60.0 ft2 1 ftO in 30.0 ft2 1 ft 0 in 30.0 ft2 1 ft 0 in 60.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds 1 ftO in Drapes/blinds 1 ftO in Drapes/blinds 1 ft 0 in Drapes/blinds 1 ft 0 in Drapes/blinds None None None None None GARAGE V# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 460 ft2 460 ft2 64 ft 8 ft 1 INFILTRATION Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1395.3 76.6 144.06 .2578 7 HEATING SYSTEM V System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 23.2 kBtu/hr 1 sys#1 COOLING.SYSTEM V System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 14 23.2 kBtu/hr 696 cfm 0.75 1 sys#1 6/29/2018 9:46 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPt1T RtIMMARY r.HFr-Kl IRT RFPORT Name: Rating Compant: Signature: Date: 6/29/2018 9:46 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 4 of 4 HOT WATER SYSTEM V System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model # Collector Model Area Volume FEF None None ft2 DUCTS V Supply -- Return -- Air CFM 25 CFM25 HVAC # Location R -Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 299 ft2 Attic 74.75 ft Proposed Qn Main cfm 44.8 cfm 0.03 0.50 1 1 TEMPERATURES Prograrnable Thermostat: Y Ceiling Fans: Cool ng an e Mar Aprr Jun Ju AugM:y Sep Oc No Dec Heat Janng1 Feb MarJX A y Jun Jul rj AugIrjri Seprl Octt Nov Dec Venting Jan Feb x Mar Apr May Jun Jul Aug Sep XOct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM ExhaustCFM FanWatts HRV Heating System Run Time Cooling System Runtime Vent 25 0 0 0 1 - Electric Heat Pump 1 -Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Main Name: Rating Compant: Signature: Date: 6/29/2018 9:46 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods 413 19th Street Permit Number: 77 Sanford , FL , MANDATORY REQUIREMENTS See individual code sections for full details. V, SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. F-1 R402.4.1 Building thermal envelcTom building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402 4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance withF1 the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones I and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Ej R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakageWindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm perr_1 square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 1 Ol/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 6/29/2018 9:46 AM EnergyGauge(@ USA - FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) F-1 R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R -value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8, Exceptions: 1 . Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary e lectric-resi stance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. EJ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or 7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manuf., air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handier enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105'F (41'C) or below 55'F (11 YC) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 6/29/2018 9:46 AM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 '/ inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100'F to 140oF (38'C to 60'C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM -1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. F-1 R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy.When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1 . The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-1 1 and the ceiling shall be insulated to a minimum of R-1 9, space permitting, or R-1 0 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM) MINIMUM EFFICACY a CFMfWATT) AIRFLOW RATE MAXIMUN CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 6/29/2018 9:46 AM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1 Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. F R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burnersF shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50*F (I O*C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40*F (4.8'C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal EJ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 6/29/2018 9:46 AM EnergyGauge@ USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory$e energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS F-1 R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 6/29/2018 9:46 AM EnergyGauge@) USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5 201.7 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R_ 6.0 2. Single-family or multiple -family 2. Single-fami y b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1- 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 3.2 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1495 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U -factor: (we ig hted average) 7a. 0.340 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.290 14. Heating system: Capacity 23.2 c) Area 7c. 203.3 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U -factor: (we ig hted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R -value) 9a. 0.0 b) Wood, raised (R -value) 9b. 15. Water heating system c) Concrete, raised (R -value) 9c. a) Electric resistance EF 0.92 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R -value) 1 OA1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R -value) 1 OA2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R -value) 10131. 13.0 2. Masonry (Insulation R -value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 1 1c. d) Multizone cooling credit d) Radiant barrier installed 1 Ild. No e) Multizone heating credit f) Programmable thermostat Yes Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Address of New Home: 413 19th Street City/FL Zip: Sanford, FL 6/29/2018 9:46:30 AM EnergyGauge@ USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary Job: 413 19th Street wrightsoft, Date: 06/29/2018 House By- XF/LM One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax:(407)629-9307 Web: www.OneStopCooling.com License: CAC032444 For: Miller Construction Services 413 19th Street, Sanford, FL Notes: Weather: Orlando Intl AP, FL, US Winter Design Conditions Outside db 42 'F Inside db 68 'F Design TD 26 'F Heating Summary Structure 15801 Btuh Ducts 2314 Btuh Central vent (25 cfm) 721 Btuh Outside air 11946 Humidification 0 Btuh pipigg 0 Btuh Equipment load 18836 Btuh Infiltration Heating Equipment Summary Method Simplified Construction quality Average Fireplaces 1 (Average) Summer Design Conditions Heatin C' i ing Area (ft) 149R 41 93 Volume (ft") 11946 11946 Airchanges/hour 0.55 0.23 Equiv.AVF (cfm) 110 46 Heating Equipment Summary Make Goodman Mfg. 49 grAb Trade GOODMAN; JAN ITROL; AMANA DISTI... Model GSZ140241K Airflowfactor 0.043 cfim/Btuh AHRI ref 7995055 0.052 dm/Btuh Summer Design Conditions Cooling Equipment Summary Outside db 92 F Inside db 74 F Design TD 18 F Daily range M Temperature rise 27 Relative humidity 50 Moisture difference 49 grAb Sensible Cooling Equipment Load Sizing Structure 13408 Btuh Ducts 1527 Btuh Central vent (25 cfm) 508 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Equipmentsensi . ble load 15041 Btuh Latent Cooling Equipment Load Sizing Structure 2312 Btuh Ducts 608 Btuh Central vent (25 cfm) 832 Btuh Outside air Equipment latent load 3752 Btuh Equipment Total Load (Sen+Lat) 18793 Btuh Req. total capacity at 0.75 SHR 1.7 ton Efficiency 8.2 HSPF Cooling Equipment Summary Make Goodman M Trade GOODMAN;..19A.NFrROL;AMANA DISTI... Cond GSZ140241K coil ARUF25B14A AHRI ref 7995055 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Hea ng input Sensible cooling 17400 Btuh Heat ng output 23200 Btuh @ 47-F Latent cool i ng 5800 Btuh Temperature rise 27 F Total cooling 23200 Btuh Actual air flow 773 cfim Actual air flow 773 cfim Airflowfactor 0.043 cfim/Btuh Airflowfactor 0.052 dm/Btuh Static pressure 0.50 in H20 Static pressure 0.50 in H20 Space thermostat Load sensible heat ratio 0.80 Capacity balance point = 37 'F Backuo: Input--OkW, Output= 0 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2018 -Jun -29 09:38:47 Q:– Pight-SuitelD Universal 201818.020RSU16793 Page 1 ACCK Services\Cascadia\413 19th Street\Cascadia.rup Calc = MJ8 House faces: N A . 9+ wrightsoft, Right -J@ Worksheet House One Stop Cooling and Heating Job: 413 19th Street Date: 06/29/2018 E r XF/LM 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC032444 1 Room name House BED2 2 Exloosedwall 139.5 ft 13.0 ft 3 Room height 8.0 It d 8.0 ft heat(bool 4 Room dimensions 11.0 x 13.0 ft 5 Room area 1493.3 fF 143.0 ft' TY Construction U -value Or HTIVI Area (ft2) Load Area 0e) Load number BtuhA?--F) B ) I or perimeter (ft) h) or perimeter (ft) Btuh) Heat cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W_ 4A5-2om 0.340 n,' 8.87 10.59 23 fsi 0 F7 202 0 0 0 q AN 2orh__._ 0.340 n 8.87 0.59 60 0 5 1 G1::::D 13A-4. 4A5-2orn 0.143 0.340 e e 3.73 8.87 2.90 29.09 332 60 252 0 3 939 535 729 1754 0 0 0 0 0 0 0 0 11jo 0.600 e 15.66 18.87 20 20 315 379 0 0 0 0 f A -4ocs f.§d 1 4 0 F65 30 266 0 8'9 0 t—G 13A-4ocs 4A5-2onn 0.143 w 3.73 2.90 308 278 iwo 805 104 332 Q 258 0.340 w 8.87 29.09 30 0 7771169 266 399 3.15 873 253 15 7'716___ 0 7'68 133 436 C 16X1 9:6 d_ 0.600. 0.408 n-. 15.66,__j8.87 1.48 1.63 2Q 1493 2Q 1493 2206 3Z9 2439 Q 143 143 211 234 7 9-QQ 14%3 T3_ 7— 7----- 777 7- N 7 6, c)AED excursion 0 178 Envelope loss/gain 12666 9864 1286 1238 12 a) Infiltration 3135 923 292 86 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 9201 1 230 Applianoeslother 1700 0 Subtotal (lines 6 to 13) 15801 13408 1578 1554 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 15801 13408 1578 1554 15 Ductloads 15% 11% 2314 1527 15% 11% 231 177 Total room load 18115 14934 18091 1731 Air required (cfm) 1 1 7731 773 77 90 Calculabons ar)proved NACCA to meet all recluirements of Manual J 8th Ed. 2018 -Jun -29 09:38.,47 FZight-Suite@ Universal 2018 18.0.20 RSU1 6793 Page I Services\Cascadia\413 19th Street\Cascadia.rup Calc= IVU8 House faces: N wrightsoft Rig ht -J@ Worksheet House One Stop Cooling and Heating Job: 413 19th Street Date: 06129/2018 By: XF/LM 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopGooling.com License: CAC032444 1 Room name LNDY MBTH 2 Exposedwall 0 ft 6.5 ft 3 Room height 8.0 ft heatl000l 8.0 ft heat/000l 4 Room dimensions 6.0 x 7.0 It 6.5 x 7.5 ft 5 Room area 42.0 fe 48.8 jt2 TY Construction U -value Or HTM Area (ft) Load Area (ft2) Load number BbjM-'F) 13tuh/It') or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat cool Gross NP/S Heat Cool Gross N/P/S Heat Cool 6 V- -'-'139 6 b G 4A5-2om 0.340 n, 8.87 10.59 0 0 0 0 0 0 0 0 0.340 nA 8.87 10.59 0 0 0 0 0 0 VL, 13A-4ocs 0.143 e 3.73 2.90 0 0 0 0 0 0 0 0 1. 1 4A5-2om 0.340 e 8.87 29.09 0 0 0 0 0 0 0 0 11jo 0.600 e 15.66 18.87 0 0 0 0 0 0 0 0 0 0 5 4A-5-2om'-'- o-w 8.8T Q la Q 13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2om 0.340 w 8.87 29.09 0 0 0 0 0 0 0 f f 5-1 2 46 11-4 12 4 i'd 6 0.600 n-, 15-06. 18-87 LQ O 0 0 o 0. C 16X1 9-0ad 0 .408 1.48 42 42 62 69 49 49 72 80 I 1.6 Q.M 42 I- - I-.. - -6 17-""----- jL 7-7 7 6 c)AED excursion 28 12 Envelope loss/gain 176 113 476 224 12 a) Infiltration 0 0 146 43 b) Roorriventlation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 176 613 622 267 Less external load 0 0 0 0 Lessransfer 0 0 0 0 Redistributon 0 0 0 0 14 Subtotal 176 613 622 267 15 Duct loads 1 15% 11% 26 70 15% 11% 911 30 Total room load 1 202 683 7131 297 Air required (dim) 9 351 30 15 Calculabons approved byACCA to meet all requirements of Manual J 8th Ed. flia- Vww-i&F"t:-.5"rt- 2018 -Jun -29 09:38.47 Right -Suite@ Universal 2018 18.0.20 RSU16793 Page 2ACCP' ... Services\CascadiaWl 3 19th Street\Cascadia.rup Calc = MA House faces- N J. V- wrightsoft, Right -J@ Worksheet House One Stop Cooling and Heating Job: 413 19th Street Date: 06/29/2018 By XIFILM 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.00m License: CAC032444 1 Room name BTH2 T012 2 Exposedwall 0 ft 0 ft 3 Room height 8.0 ft heatIoDol 8.0 ft heat/000l 4 Room dimensions 7.0 x 6.0 ft 5.5 x 6.0 ft 5 Room area 42.0 f12 33.0 ft' TY Construction U -value Or HTM Area (ft) Load Area (ft) Load number Btuhffi'-'F) Btuh/fl or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat cool Gross NP/S Heat Cool Gross NP/S Heat Cool 6 n 0 0 G 4A5-2om 0.340 in' 8.87 10.59 0 0 0 0 0 0 4?qrn 0.34.0 O q 0 0 0 0 0 0 13A-4ocs 0.143 h_ e 3.73 2.90 0 0 0 6 1,11 T:::G 4A5-2om 0.340 e 8.87 29.09 0 0 0 0 0 0 0 0 D MID 0.600 e 15.66 18.87 0 0 0 0 0 0 0 Vj 18A:4'6c—s--"'- 2-9-0 0 b 0 r'"-'-'o 0 0 s i—JMT t—G 13A4ocs 0.143 w 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2orn 0.340 w 8.87 29.09 0 0 0 0 0 0 0 0 6MM 77fN-, 777—,6 6 b 0 0 Q 0 0 0 16X19-0ad 0.408 1.48 1.63 42 42 62 69 33 33 49 54 jf' 7 77 6 c)AED excursion 3 2 Envelope losstgain 1 62 66 49 52 12 a) Infiltration 0 01 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 62 66 49 52 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redisbibubon 0 0 0 14 Subtotal 62 66 49 52 15 Ductloads 1 15% 11% 9 7 15% 11% 7 Total room load 71 73 56 57 Air required (ckn) 3 4 2 3 Calculabons approved byACCA to meet all requirements of Manual J 8th Ed. 2018 -Jun -29 09:38:47 F?jght-Suite@ Universal 2018 18.0.20 RSU16793 Page 314CC' Servioes\Cascadia\413 19th Street\Cascadia.rup Calc = MJ8 House faces: N wrightsoft, Right -M) Worksheet House One Stop Cooling and Heating Job: 413 19th Street Date: 06/29/2018 By- XF/LM 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www0neStopCooling.00m License: CAC032444 1 Room name MBED BED3 2 Exposedwall 31.5 ft 26.0 ft 3 Room height 8.0 ft heatt000l 8.0 ft heat/000l 4 Room dimensions 1.0 x 219.3 ft 11.0 x 15.0 ft 5 Room area 219.3 ft2 165.0 ft2 TY Construction LI -value Or HTM Area W) Load Area (ft2) Load number Btuh/ft2-'F) BtuhAl) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ocs 0 4A-201`11 0.346 0:340 n n 8.7 "`110 5'9 8.87 10:59 0 0 0 2 0 0 o To 0 0 0 0 Vl-::D 13A-4ocs 0.143 e 3.73 2.90 148 148 552 429 0 0 0 1 G 4A5-2om 0.340 e 8.87 29.09 0 0 0 0 0 0 0 0 11jo 0.600 e 15.66 18.87 0 0 0 0 0 0 0 0 Q Vfb 9 7, 3O 2-7-6, 214 AA -5,4.m- Q 3-49 s H 7 26 T—G 13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 120 105 392 304 4A5-2om 0.340 w 8.87 29.09 0 0 0 0 15 0 133 436 0 0 70 61 6 0.660 871,5'.66 —18' o 165 244C16Xl§:bad OA08 148 1.63 219 219 324 358 165 00 77%7- 7-, 1 7- 77-- J T.- 777- 1 31 7 7 6 c)AED excursio, 58 165 Envelope losstgain 2389 1266 1898 1430 12 a) Infiltration 708 208 584 172 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Applianoestother 0 0 Subtotal (lines 6 to 13) 1 3097 1935 2482 1832 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 3097 1935 2482 1832 15 Duct loads I % 11% 454 220 1 ol o 3CA 209 Total room load 3550 2155 1 2846 2041 Air required (cfim) 1 152 112 121 106 Calculatons approved byACCA to meet all requirements of Manual J 8th Ed. 2018 -Jun -29 09:38:47 Page 4 Ijrd Right -Suite@ Universal 2018 18.0.20 RSU1 6793 ServioesCascadiaWl 3 19th Street\Cascadia.rup Calc = MJ8 House faces: N wrightsoft, Right -A) Worksheet House One Stop Cooling and Heating Job: 413 19th Street Date: 06/29/2018 By-. XF/LM 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC032444 1 Room name KIT FAM/DINE 2 Exposedwall 0 ft 58.0 ft 3 Room height 8.0 ft heatIoDol 8.0 ft heaV000l 4 Room dimensions 1.0 x 251.3 ft 1.0 x 499.5 ft 5 Room area 251.3 ft2 499.5 V TY Construction U -value Or HTM Area M) Load Area (ft2) Load number Btuh/ft'217) Btuh/F) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 o 77-77-S 777-149 77- 6 7-11-4 il AA&2orh 0.340 r 8.87 0 0 0 0 0 23 d 241 0.340 n 8.87 10.59 0 0 0 202 535 638 VL, 13A4ocs 0.143 e 3.73 2.90 0 0 0 0 184 104 387 300 1. 1 4A5-2om 0.340 e 8.87 29.09 0 0 0 0 60 0 535 1754 11jo 0.600 e 15.66 18.87 0 0 0 0 20 20 315 379 I SA- 711-9 lgto 6 0 6-7 6 70 0- 0-34D LsLl 081— J'O-Tl 0 L-"o 0 0 0 I—G 13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 48 48 179 139 4A5-2om 0.340 w 8.87 29.09 0 0 0 0 0 0 0 0 I:L---- 1YC b-01' 7 77Y:I 28 66 742 777 -0 QD 11110-- - a -d -- - ---- 00' 4008Q h J 8.87 20 20 Ji---3-15 o o C 16X1 6:6 1 .48 1.63 251 251 371 410 500 500 738 816 Ko 0.Q0 f 71-L 7 T-- X- 6 c)AED excursion 89 141 Envelope lossigain 1 752 742 5233 1 4558 12 a) Infiltration 0 0 1303 384 b) Roo.rn ventilation 0 0 0 0 13 Internal gains, Occupants @ 230 0 0 0 0 Appliancestother 1200 0 Subtotal (lines 6 to 13) 752 1942 6536 4942 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 752 194 6536 4942 1 Duct loads 1 15%1 11%1 110 221 15% 11% 957 563 Total room load 862 21 64 7493 Air required (cfm) 37 112 320 Calculabons approved byACCA to meet all requirements of Manual J 8th Ed. 41- Vww-iw"t;!5C'rIt- 2018 -Jun -29 09:38'.47 Right -Suite@ Universal 2018 18.0.20 RSU1 6793 Page 5 Services\CascadiaA 13 19th Street\Cascadia.rup Calc = MJ8 House faoes: N J. I+ wrightsoft Right -J@ Worksheet House One Stop Cooling and Heating Job: 413 19th Street Date: 06/29/2018 By: XF/LM 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www0neStopCooling.00m License: CAC032444 1 Room name MWIC WIC2 2 Exposed wall 0 It 4.5 ft 3 Room height 8.0 ft heaV000l 8.0 ft heatl000l 4 Room dimensions 6.0 x 4.5 ft 5.0 x 4.5 ft 5 Room area 27.0 ft2 22.5 fF TTYy Construction U -value Or HTM Area OF) Load Area (ft2) Load number Btuh/ft2--F) Btuh/ft') or perimeter (ft) h) or perimeter (ft) Btuh) Heat cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 4A5-2om 0.340 8.87 10.59 0 0 o 0 b 0 0 0 0 4A 0.34b 87 10.59 0 q 0 0 0 0 0 0 0 1 t:!GD 13A-4ocs 4A5-2onn 0.143 0.340 e e 3.73 2.90 8.87 29.09 0 0 6 0 0 0 6 0 0 6 0 0 6 0 I'lio 0.600 e 15.66 18.87 0 0 0 0 0 0 0 0 Vt_G 13A -7466i 6.121:3 716 J 6 6 4A 5- M-- Q. 340 s-- 1 Q.T6 O 0 IL13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 36 36 134 104 G 4A5-2orn 0.340 w 8.87 29.09 0 0 0 0 0 0 0 0 12 -Ow W, 2 6 i.51 6 0 6 6 0 L—Q 0' 0 C 16X19-0 d------ 0.408 1.48 1.63 27 40 44 23 23 33 37 2,7 7 7 7' 2 "-L I 6 c)AED excursion 2 8 Envelope lossIgain 40 42 306 133 12 a) Infiltration 0 01 101 30 b) Roomventlation 0 0 0 0 13 Internal gains: Oocupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 40 42 407 163 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 40 421 407 163 15 Ductloads 15% 11% 6 5 15%1 11% 60 19 Total room load 46 47 4671 182 Air required (cfm) 2 2 20 9 Calculabons approved byACCA to meet all requirements of Manual J 8th Ed. www-iqftt w4:,1rt- 2018 -Jun -29 09:38.47 Right-Suite(D Universal 2018 18.0.20 RSU1 6793 Page 6 Services\Cascadia\413 19th Street\Cascadia.rup Calc = MJ8 House faces: N wrightsoft, Duct System Summary House One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com Lirense: CAC032444 P-' -. -111 0rojqdt, forma iow: For: Miller Construction Services 413 19th Street, Sanford, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H20 0.16 in H20 0.34 in H20 0.170 / 0.170 in H20 0.214 in/1 00ft 773 cftn 159 Job: 413 19th Street Date: 06/29/2018 By-. XF/LM Cooling 0.50 in H20 0.16 in H20 0.34 in H20 0.170 / 0.170 in H20 0.214 in/100ft 773 drn 14 Wll I- . - .%-, -'- I 5 - - - ' -. I r , - . . I I S'Upply,,iBreirich..'Detaill,,TAble' Name Design Btuh) Htg cfM) Clg cfrn) Design FIR Diam in) HxW in) Duct Mat Actual Ln (ft) Ftg.Eqv Ln (ft) Trunk BED2 1731 77 90 0.233 6.0 Ox 0 VlFx 30.8 115.0 SO BED3 h 2846 121 106 0.238 6.0 ox 0 VlFx 28.1 115.0 SO BTH2 c 73 3 4 0.249 4.0 Ox 0 VlFx 31.3 105.0 st2 FAM DINE h 2498 107 95 0.244 6.0 ox 0 VlFx 34.3 105.0 st2 FAM DINE -A h 2498 107 95 0.232 6.0 Ox 0 VlFx 31.6 115.0 stl FAM DINE -B h 2498 107 95 0.214 6.0 Ox 0 VlFx 38.5 120.0 stl Krr c 2164 37 112 0.240 6.0 Ox 0 VlFx 26.6 115.0 sti LNDY c 683 9 35 0.257 4.0 Ox 0 VlFx 32.5 100.0 st2 MBED h 3550 152 112 0.240 7.0 Ox 0 VlFx 31 A 110.0 st2 MBTH h 713 30 15 0.282 4.0 Ox 0 VlFx 25.6 95.0 st2 MWIC c 47 2 2 0.242 4.0 Ox 0 VlFx 30.3 110.0 st2 T012 C 57 2 3 0.274 4.0 Ox 0 VlFx 23.9 100.0 st2 WC2 h 467 1 20 1 9 1 0.230 1 4.0 1 Ox 0 VlFx 32.7 115.0 sti etai[labl&. BoWltafic values have been manuallyoveaidden wrightsoft- 2018 -Jun -29 09:38-.48 Pight-Suite@) Universal 2018 18.020 RSU16793 Page 1 C0k SerAces\Casradia\413 19th Street\Cascadia.rup Calc = MJ8 House faces: N Trunk Htg Clg Design Veloc Diam HxW Duct Name Type 011111) dm) FIR fpm) in) in) Material Trunk sti PeakAVF 469 507 0.214 645 12.0 0 x 0 VinlFlx st2 I PeakAVF I 305 I 267 I 0.240 I 689 I 9.0 I 0 x 0 I VinIFIx I I BoWltafic values have been manuallyoveaidden wrightsoft- 2018 -Jun -29 09:38-.48 Pight-Suite@) Universal 2018 18.020 RSU16793 Page 1 C0k SerAces\Casradia\413 19th Street\Cascadia.rup Calc = MJ8 House faces: N Name Grille Size (in) Htg CfM) CIg 0m) TEL ft) Design FR Veloc fpm) Diam in) HxW in) Stud/Joist Opening (in) Duct Mat! Trunk rb1 Ox 0 773 773 0 0 0 0 Ox 0 VIFx Pk wrightsoft 2018 -Jun -29 09:38-.48 Rght-Suite0 Universal 2018 18.020 RSU16793 Page 2 ACCK Services\CascadiM413 19th Street\Cascadia.rup Calc = MJ8 House faces: N Static Pressure and Friction Rate Job: 413 19th Street wrightsoft, Date: 06/29/2018 House %ir. XF/LM One Stop Cooling and Heating 7225 Sandsoove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC032444 For: Miller Construction Services 413 19th Street, Sanford, FL Available Static Pressure Heating Cooling in H20) (in H20) External static pressure 0.50 0.50 Pressure losses Cooling i n/1 00ft) Coil 0 0 Heatexchanger 0 0 Supplydiffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 supply Return ft) (ft) Measured length of run -out 18 0 Measured length of trunk 21 0 Equivalent length of fittings 120 0 Total length 159 0 Total effective length 159 Heating Cooling i n/1 00ft) i n/1 00ft) Supply Ducts 0.214 > 0.18 0.214 > 0.18 Return Ducts 0.214 > 0.18 0.214 > 0.18 Supply 4X=35, 11A=20, 11G=5, 11G=5, 1A=35, 11G=5, 11G=5, 11G=5, 11G=5:TotalEL=120 Return TbtalEL=0 wrightsoftl Nght-SuiteV Universal 2018 18.0.20 RSU1 6793 2018 -Jun -29 09:38:48 Page 1 Services\CascadiaA 13 19th StreeACascadia.rup Calc = MJ8 House faces: N 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cascadia Builder Name: Miller Construction Services Street: 413 19th Street Permit Office: City of Sanford City, State, Zip: Sanford , FL , Permit Number: Y 0 Owner: Miller Construction Services Jurisdiction: 691500 Lu Design Location: FL, Orlando C C) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between winclow/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind i)ioina and wirina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilinas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC -400. 6/29/2018 9:46 AM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 N EF1 = 50 CFIVI Fan EF2 = 80 CFIVI Fan EF3 = 110 CFIVI Fan EFL1 = 50 CFIVI Fan EFL2 = 80 CFIVI Fan EFL3 = 110 CFIVI Fan Lineset Chase — — Condensate— - — T = Thermostat 1 0 SRB = Small Reduction Box LRB = Large Reduction Box FBB = Field Built Box Job #: 413 19th Street Performed by)(F/LM for: Mier UnstrLicton Services 41319thStrest Sanford FL Level 1 One Stop Cooling and Heating 7225 Sandsoove, Court Winter ParK FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 wAw CneSto pCDol ing.a:)m Scale: 1 :62 Page 1 Rigtt-SdegUriversad2018 laC.2DRSU16793 2018-Juv28163518 dEM 0519th Street\Cascaclamp RECORD Copy POW----. ddd DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00—THERMAL INSULATION SECTION: 07 27 00—AIR BARRIERS REPORT HOLDER: JOHNS MANVILLE 71717 TH STREET DENVER, COLORADO 80202 EVALUATION SUBJECT: q TM0'o 1 0 - 3 19 7 JM CORBONDO oc SPF SPRAY FOAM 1CC ICC 1CC N o g Q" c '"" PMG C — Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council WSSPC) Award in Excellence" kM-kNSQ, 11 IL 4ILILNMau INTERNATIONAL A Subsidiary of CODECOUNCII! cc j ICGES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not MRS specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a C recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as IS011EC I M5 to anyfinding or other matter in this report, or as to any product covered by the report. Pmch Ce"=km I 410W Copyright'o 2017 ICC Evaluation Service, LLC. All rights reserved. if IMES Evaluation Report ESR -3776 Reissued November 2017 This report is subject to renewal November 2018. wwwJcc-es.orq_ 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Counci/15 DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation Section: 07 27 00—Air Barriers REPORT HOLDER: JOHNS MANVILLE 71717 TH STREET DENVER, COLORADO 80202 800) 654-3103 WWW.M.COM EVALUATION SUBJECT: JM CORBOND 8 oc SPF SPRAY FOAM 1.0 EVALUATION SCOPE Compliance with the following codes: N 2015, 2012 and 2009 International Building Code (IBC) E 2015, 2012 and 2009 International Residential Code IRC) 0 20i5, 2012 and 2009 Intemational Energy Conservation Codee (I ECC) 0 2013 Abu Dhabi Intemational Building Code (ADIBC)' tThe ADIBC is based on the 2009 113C. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Property evaluated: Surface -burning characteristics Physical properties Thermal resistance Attic and crawl space applications Air permeability Exterior walls in Types I through IV construction 2.0 USES JM Corbonde oc SPF open cell spray foam is used as a nonstructural thermal insulating material in Types 1, 11, 111, IV and V construction (113C) and dwellings under the IRC. The insulation is for use in wall cavities, floor assemblies, ceiling assemblies or attics and crawl spaces when installed in accordance with Section 4.4; and in Types I through IV construction when installed in accordance with Section 4.5. Under the IRC, the insulation may be used as air impermeable insulation when installed in accordance with Section 3.4. 3.0 DESCRIPTION 3.1 General: JM Corbondo oc SPF is a spray -applied cellular polyurethane foam plastic insulation installed as a component of wall assemblies, ceilings, floors, crawlspaces and cavities of roofs. The foam plastic insulation is a two -component, open -cell, one-to-one by volume spray foam system with a nominal density of 0.5 pcf (8 kg/M3). The insulation is produced in the field by combining a polymeric isocyanate (A component) with a polymeric resin blend (13 component). The insulation components have a shelf life of six months when stored in factory -sealed container at temperatures between 401F 40C) and 850F (291C) before installation. 3.2 Surface -burning Characteristics: The insulation, at a maximum thickness of 4 inches 102 mm) and a nominal density of 0.5 pcf (8 kg /M3) , has a flame spread index of 25 or less and a smoke -developed index of 450 or less when tested in accordance with ASTM E84. Thicknesses greater than 4 inches (102 mm) are recognized, based on a flame spread index of 25 or less, when the insulation is covered with a minimum 1/2 -inch -thick (12.7 mm) gypsum wallboard or an equivalent thermal barrier complying with and installed in accordance with the applicable code. 3.3 Thermal Resistance (R -values): The insulation has thermal resistance (R -value), at a mean temperature of 751F (240C), as shown in Table 1. 3.4 Air Permeability: JM Corbondo oc SPF, at a minimum thickness of 3.75 inches (95 mm), is considered air -impermeable insulation in accordance with 2015 and 2012 IRC Section R806.5 (2009 IRC Sections R806.4) and 2015 IBC Section 1203.3 based on testing in accordance with ASTM 2178. 3.5 TPR 2 Fireshelle JM -TC Coating: TPR2 Fireshelle JM -TC Coating is a one -component, water-based polymer inturnescent coating manufactured by TPR2 Corporation (ESR -3997). The coating is supplied in 5 -gallon (19 L) pails and 55 -gallon (208 L) drums and has a shelf life of one year when stored in factory -sealed containers at temperatures between 45'F (7.2'C) and 951F 35-C). 3.6 TPR 2 Fireshello F10E and TPR 2 FireShell TB: TPR 2 Fireshelle F10E and TPR 2 Fireshell Coating are identical to TPR 2 Fireshello JM -TC Coating and may be used wherever TPR 2 Fireshelle JM -TC Coating is specified. 3.7 TPR 2 Fireshelle JM -IC Coating: TPR 2 Fireshello JM -IC Coating is a one -component, water- based polymer inturnescent coating manufactured by TPR 2 Corporation. The coating is supplied in 5 -gallon (19 Q pails and 55 -gallon (208 L) drums and has a shelf life of one ICGES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed vice, LLC, express or heportorareconunendationforitsuse. There is no warranty by ICC Evaluation Setasanendorsementofthesuhjectofthet _00 to any.finding or other matter in this report, or as to any product covered by the report. Copyright @ 2017 ICC Evaluation Service, LLC. All rights reserved - Page 1 of 4 e ESR -3776 I Most WidelyAccepted and Trusted Page 2 of 4 year when stored in factory -sealed containers at temperatures between 45'F (7.2*C) or 951F (350C). 3.8 TPR 2 Fireshello 1134 Coating: TPR 2 Fireshello 1134 Inturnescent Coating is identical to TPR 2 Fireshello JM -IC Intumescent Coating and may be used wherever TPR 2 Fireshello JM -IC Inturnescent Coating is specified. 3.9 DC 315 Coating: DC 315 intumescent coating is manufactured by International Fireproof Technology, Inc. / Paint to Protect Inc. (ESR -3702) and is a water-based inturnescent coating supplied in 5 -gallon (19 Q pails and 55 -gallon (208 L) drums. The coating material has a shelf life of 12 months when stored in factory -sealed containers at temperatures between 501 F (1 O'C) and 801 F (270C). 4.0 INSTALLATION 4.1 General: JM Corbondo oc SPF insulation must be installed in accordance with the manufacturer's published installation instructions and this report. A copy of the manufacturer's published instructions must be available at all times on the jobsite during installation. 4.2 Application: The JM Corbondo oc SPF insulation is spray applied on the jobsite using a volumetric positive displacement pump as identified in the Johns Manville application guide. The insulation must be applied when the substrate temperature is between 450F (70C) and 120OF (490C) and must be protected from the weather during and after application. The insulation must not be used in areas that have a maximum service temperature greater than 1801F (821C). The substrates to which the insulation is applied must be clean, dry and free of frost, ice, loose debris, or contaminates that will interfere with adhesion of the spray foam insulation. The insulation must not be used in electrical boxes or junction boxes or in contact with rain, water or soil. The insulation is applied in passes having a maximum thickness of 12 inches (305 mm) per pass. Multiple passes can be applied to obtain the desired thickness. The cure time between passes is negligible where multiple passes are used. 4.3 Thermal Barrier: 4.3.1 Application with a Prescriptive Thermal Barrier: JM Corbondo oc SPF insulation must be separated from the interior of the building by an approved thermal barrier Of 1/2 -inch -thick (12.7 mm) gypsum wallboard or an equivalent 15 -minute thermal barrier complying with and installed in accordance with the applicable code, except where the installation complies with the requirements set forth in Section 4.3.2. When installation is within an attic or crawl space as described in Section 4.4, a thermal barrier is not required between the foam plastic and the attic or crawl space, but is required between the insulation and the interior of the building. There is no thickness limit when installed behind a code -prescribed thermal barrier except as noted in Section 4.4.2.1. 4.3.2 Application without a Prescriptive Thermal Barrier: 4.3.2.1 Application with TPR 2 Fireshell' JM -TC Coating (ESR -3997): The prescriptive 15 -minute thermal barrier may be omitted when installation is in accordance with this section. The insulation and coating may be spray -applied to the interior facing of walls and ceilings and may be left exposed as an interior finish without a code -prescribed 15 -minute thermal barrier. The thickness of the foam plastic insulation and intumescent coating applied to the vertical wall surfaces and underside of ceilings must comply with this section and Table 2. The JM Corbondo oc SPF insulation must be covered on all surfaces with the intumescent coating at a minimum wet film thickness and coverage rate indicated in Table 2 in accordance with the coating manufacturer's instructions and this report. Surfaces to be coated must be dry, clean and free of dirt, loose debris and other substances that could interfere with the adhesion of the coating. The coating is applied in a single coat by airless spray equipment at ambient temperatures between 55'F and 95*F (12'C and 35'C) and relative humidity of not more than 65 percent. 4.3.2.2 Application with DC 315 Inturnescent Coating ESR -3702): The prescriptive 15 -minute thermal barrier may be omitted when installation is in accordance with this section. The insulation and coating may be spray -applied to the interior facing of walls and ceilings and may be left exposed as an interior finish without a code -prescribed 15 -minute thermal barrier. The thickness of the foam plastic insulation and intumescent coating applied to the vertical wall surfaces and underside of ceilings must comply with this section and Table 2. The JM Corbondo oc SPF insulation must be covered on all surfaces with the inturnescent coating at a minimum wet film thickness and coverage rate indicated in Table 2 in accordance with the coating manufacturer's instructions and this report. Surfaces to be coated must be dry, clean and free of dirt, loose debris and other substances that could interfere with the adhesion of the coating. The coating is applied in a single coat by airless spray equipment at ambient temperatures between50*F (10*C) and 90'F (32'C) and relative humidity of not more than 60 percent. 4.4 Ignition Barrier - Attics and Crawl Spaces: 4.4.1 Application with a Prescriptive Ignition Barrier: When JM Corbond 0 oc SPF insulation is installed within attics or crawl spaces where entry is made only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 and IRC Sections R316.5.3 and R316.5.4, as applicable. The ignition barrier must be consistent with the requirements for the type of construction required by the applicable code, and must be installed in a manner so that the foam plastic insulation is not exposed. The attic or crawl space area must be separated from the interior of the building by an approved 15 -minute thermal barrier as described in Section 4.3.1. JM Corbondo oc SPF insulation, as described in this section, may be installed in unvented attics in accordance with 2015 and 2012 IRC Section R806.5 (2009 IRC Section R806.4) or 2015 IBC Section 1203.3 4.4.2 Application without a Prescriptive Ignition Barrier: Where the spray -applied insulation is installed in accordance with the requirements of this section, the following conditions apply: a) Entry to the attic or crawl space is to service utilities, and no storage is permitted. b) There are no interconnected attic or crawl space areas. c) Air in the attic or crawl space is not circulated to other parts of the building. d) Attic ventilation is provided when required by IBC Section 1203.2 or IRC Section R806, except when air -impermeable insulation is permitted in unvented attics in accordance with the 2015 IBC Section 1203.3 or 2015 and 2012 IRC Section R806.5 z ESR -3776 I Most Widely Accepted and Trusted Page 3 of 4 2009 IRC Section R806.4). Under -floor (crawl space) ventilation is provided when required by 2015 IBC Section 1203.4 (2012 and 2009 IBC Section 1203.3) or IRC Section R408.1, as applicable. e) Combustion air is provided in accordance with International Mechanical Codeo Section 701. 4.4.2.1 Application with TPR 2 Fireshello JM -IC Intumescent Coating: In attics, JM Corbond 0 oc SPF insulation may be spray -applied to the underside of roof rafters, and in crawl spaces, JM Corbond 0 oc SPF insulation may be spray -applied to the underside of floors as described in this section. The thickness of the foam plastic insulation and intumescent coating applied to the vertical wall surfaces and underside of ceilings must comply with this section and Table 2. The JM Corbondo oc SPF insulation must be covered on all surfaces with the inturnescent coating at a minimum wet film thickness and coverage rate indicated in Table 2 in accordance with the coating manufacturer's instructions and this report. The insulation may be left exposed without a covering or coating. The attic or crawl space must be separated from the interior of the building by an approved 15 -minute thermal barrier as described in Section 4.3.1. 4.4.2.2 Application with Paint to Protece DC315 Inturnescent Coating: In attics, JM Corbondo oc SPF insulation may be spray -applied to the underside of roof rafters, and in crawl spaces, JM Corbonde ocx SPF insulation may be spray -applied to the underside of floors as described in this section. The thickness of the foam plastic insulation and intumescent coating applied to the vertical wall surfaces and underside of ceilings must comply with this section and Table 2. The JM Corbondo oc SPF insulation must be covered on all surfaces with the intumescent coating at a minimum wet film thickness and coverage rate indicated in Table 2 in accordance with the coating manufacturer's instructions and this report. The insulation may be left exposed without a covering or coating. The attic or crawl space must be separated from the interior of the building by an approved 15 -minute thermal barrier as described in Section 4.3.1. 4.4.2.3 Use on Attic Floors: JM Corbondo oc SPF insulation may be installed at a maximum thickness of 16 inches (406 mm) between and over joists in attic floors' The JM Corbondo oc SPF insulation must be separated from the interior of the building by an approved thermal barrier. The coatings specified in Sections 4.4.2.1 and 4.4.2.2 and the ignition barrier in accordance with IBC Section 2603.4.1.6 and IRC Section R316.5.3 may be omitted. 4.5 Exterior Walls in Types 1, 11, 111 and IV Construction: When used on exterior walls of Type 1, 11, III and IV construction, the JM Corbondo oc SPF spray -applied polyurethane insulation must comply with IBC Section 2603.5 and this section, and the insulation must be installed at a maximum thickness indicated in Table 3. The potential heat of the JM Corbond5 oc SPF insulation is 12,385 Btu/Ibs (28802 MJ/kg). 5.0 CONDITIONS OF USE The JM Corbonde oc SPF insulation described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 This evaluation report and the manufacturer's published installation instructions, when required by the code official, must be submitted at the time of permit application. 5.2 JM Corbondo oc SPF insulation and applicable coatings must be installed in accordance with the manufacturer's published installation instructions, this report and the applicable code. The instructions within this report govern if there are any conflicts between the manufacturer's published installation instructions and this report. 5.3 JM Corbond@) oc SPF insulation must be separated from the interior of the building by an approved 15 -minute thermal barrier, as described in Section 4.3.1, except as noted in Section 4.3.2. 5.4 JM Corbond@ oc SPF insulation must be protected from the weather during and after application. 5.5 JM Corbondo oc SPF insulation must be applied by installers certified by Johns Manville or the Spray Polyurethane Foam Alliance (SPFA). 5.6 Use of JM Corbond (P oc SPF insulation in areas where the probability of termite infestation is "very heavy" must be in accordance with 2015 and 2009 IBC Section 2603.8 (2012 IBC Section 2603.9) or IRC Section R318A as applicable. 5.7 Jobsite certification and labeling of the insulation must comply with 2015 IRC Sections N1101.10.1 and N1101.10.1.1 (2012 IRC Sections N1101.12.1 and N1101.12.1.1 or 2009 IRC Sections N1101.4 and N1101.4.1) and 2015 and 2012 IECC Sections C303.1.1, C303.1.1.1, R303.1.1 and R303.1.1.1 2009 IECC Sections 303.1.1 and 303.1.1.1), as applicable. 5.8 JM Corbond@ oc SPF insulation is produced by Johns Manville under a quality control program with inspections by ICC -ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC -ES Acceptance Criteria for Spray -applied Foam Plastic Insulation AC377), dated April 2016, including reports of tests in accordance with Appendix X of AC377. 6.2 Reports of room corner tests in accordance with NFPA 286. 6.3 Report of air leakage testing in accordance with ASTM E2178. 6.4 Report of critical radiant flux test in accordance with NFPA 259. 6.5 Report on fire propagation characteristics test in accordance with NFPA 285. 7.0 IDENTIFICATION Components for JM Corbond V oc SPF insulation are identified with the manufacturer's name (Johns Manville), address and telephone number; the product trade name JM Corbonde oc SPF); product type (A or B component); use instructions; the density; the flame -spread and smoke -developed indices; the evaluation report number ESR -3776). Inturnescent coatings described in Sections 3.6, 3.7 and 3.8 are identified with the manufacturer's name and address, the product name and use instructions. International Fireproof Technology Inc. / Paint To Protect Inc. DC 315 coating is labeled with the manufacturer's name and address; the product name; the date of manufacture, the shelf life or expiration date; the manufacturer's instructions for application, and evaluation report number (ESR -3702). TPR 2 Corporation Fireshell JM -TC coating is labeled with the manufacturer's name and address; the product name; the date of manufacture, the shelf life or expiration date; the manufacturer's instructions for application, and the evaluation report number (ESR -3997). ESR -3776 I Most WidelyAccepted and Trusted Page 4 of 4 TABLE 1 -THERMAL RESISTANCE (R -VALUES) THICKNESS (inches) R -VALUE ff ft2 h/Btu) 1 3.8 2 7.4 3 11 3.5 13 4 14 5 18 5.2 19 5.5 20 6 22 7 25 7.5 27 8 29 9 33 10 36 11 40 12 43 13 47 14 51 15 54 16 58 For SI: 1 inch = 25.4 mm; 11F ft2 h/Btu = 0.176 110 k. M2[W. Calculated R -values are based on tested K -values at 1 - and 3.5 -inch thicknesses R -values greater than 10 are rounded to the nearest whole number TABLE 2 -ALTERNATE ASSEMBLIES WITHOUT A PRESCRIPTIVE THERMAL BARRIER OR IGNITION BARRIER 1 Coating2 Max. Insulation Max. Insulation Dry Film Wet Film Application Applicable Test 11 Thickness Thickness Thickness Thickness Rate Report Section Submitted Overhead Surfaces Vertical wall studs. minimum) Perimeter fire barrier system complying with 2015 and 2012 IBC Section 715.4 (2009 IBC Section 714.4) as Perimeter Fire Barrier AC377) System exterior wall assembly. Surfaces Full cavity depth or less of JM Corbond" oc SPF insulation applied using exterior sheathing as substrate and Cavity insulation covering the width of the cavity and inside of stud flange. Minimum 5/8 -inch -thick Type X exterior gypsum sheathing complying with ASTM C1 177. (for Base wall system 3 JM -TC, 9.5 inches 7.5 inches 12 mils, 18 mils 1.23 gal/1 00 W 4.3.2.1 NFPA 286 F10E or 241 mm) 191 mm) 0.30 mm) 0.51 mm) 0.508 L/M2) TB I DC 315 11.5 inches 7.5 inches 12 mils 18 mils 1. 12 gal/1 00 W 4.3.2.2 NFPA 286 292 mm) 191 mm) 0.30 mrn 1 m0.51 mm) 0.508 L/ M2) JM -TC or 9.5 inches 7.5 inches 3 mils 4 mils 0.27 gal/100 W 4.4.2.1 AC377 1134 241 mm) 191 mm) 0.08 mm) 0.10 mm010 0. 113 L/ M2) Appendix X DC 315 11.5 inches 9.5 inches 3 mils Is4mils4 0.25 gal/1 00 W 4.4.2.2 AC377 292 mm) 191 mm) 08 mm) _ 0 100.10mm) 0.112L /M2) Appendix X For SI: 1 inch = 25.4 mm; 1 mil = 0.0254 mm; 1 gallon = 3.38 L; 1 ft2 = 0.93 M2. See Section 4.3.2 and 4.4.2. 2 See Section 3.5, 3.6, 3.7, 3.8 and 3.9. TABLE 3-NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES WALL COMPONENT MATERIALS 1 - Concrete wall. 2 - Concrete Masonry wall. 3 - 1 layer of 5 /8 -inch thick Type X gypsum wallboard installed on the interior side of minimum 35/a inch deep, minimum No. 20 gage, yalvanized steel studs spaced a maximum of 24 -inch on center. Gypsum wallboard must be Base wall system - attached with No. 6, 1 /4 -inch -long self -tapping screws located 8 inches on center along the perimeter and 12 Use either 1, 2, or inches in the field of wallboard. Gypsum wallboard joints must be taped and treated with joint compound in accordance with ASTM C840 or GA -216. Lateral bracing installed minimum every 4 -ft vertically or as required. Wall stud cavities shall be filled at each floor line with minimum 4 IbS/ft3 density mineral wool, friction fit between steel wall studs. Perimeter fire barrier system complying with 2015 and 2012 IBC Section 715.4 (2009 IBC Section 714.4) as Perimeter Fire Barrier applicable, shall be installed to fill void between the edge of the concrete floors slab, and the interior surface of the System exterior wall assembly. Full cavity depth or less of JM Corbond" oc SPF insulation applied using exterior sheathing as substrate and Cavity insulation covering the width of the cavity and inside of stud flange. Minimum 5/8 -inch -thick Type X exterior gypsum sheathing complying with ASTM C1 177. (for Base wall system 3 Exterior sheathing above) 1 - Any noncombustible exterior wall covering material. Exterior Wall Covering 2 - Any noncombustible exterior wall covering system with a combustible water resistive barrier (WRB) that has Use either I or 2 successfully been tested in accordance with NFPA 285. Combustible material, other than the WRB, is not allowed on the exterior side of the exterior sheathing. cu u 4 A RECORD COPY1%.L. ALPINEM r. "CO". Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32837 Phone: (800)755-6001 alpineitw.com Site Information: istomer Accu -Span Truss Company Job Number- 21218 Wescription: Cascadia Home /CasGadia Home -MILLER CONSTRUCTION Jdress: lot 413 19th Street I City, State, Zip: SANFORD, FL 32771 Name, Address and License # of Structural EOR if one exists for the building: Name: License #: Address: city State, Zip: Job Engineering Criteria: Design Code: FBC 2017 RES Wind'Standard: ASCE7-10 Wind Speed (mph): 140 State: View Version: 17.02.01.1115.21 JRef #: 1Wce4080005 RoofLoad(PsO: 20.00-7.00-0.00- FloorLoad(psO: None 10.00 This package contains a job notes page, 8 truss drawings and 3 details. Item Seal # Truss 1 186.18.0952.16299 A01 3 186.18.1543.00309 A03 5 186.18.0952.16455 A05 7 186.18.0952.16284 B01 Florida Certificate of Product Approval #FL1 999 Item Seal # Truss 2 186.18.0952.16285 A02 4 186.18.0952.16392 A04 6 186.18.1543.00278 A06 8 186.18.0952.16330 B02 G) 7 Me 3 19 7 ATE O v. 0 R This document has been electronically signed and sealed using a Digital Signature. Printed copies without an original signature must be 07/05/2018 verified using the original electronic version, Printed 7/5/2018 3:56:26 PM 6 a Job Number: 21218 Ply: 1 SEQN: 142735 T7 GABL Cust: R408 JRef: 1Wce4080005 Cascadia Home /Cascadia Home -MILLER CONSTRUCTION Qty FROM: JB DrwNo: 186.18.0952.16299 Truss Label: A01 KM WHK 07105/2018 12 1 'j"4 2"' '8 31 2 0"12 4-- -- 4- 6' i 4 -- 5X6 P K 3 F— 1-3X4 Eo 3X4 F H N T4 5X65X6E z U4 –5X6 3X4 D 6X8 C B xA1AB T _1AQ 5X8 SX6 1.5 5k6 B2 12 40' 912"10 j 12 10, 1'4" 0. 30' 10 9'10"4 L 0 2 11 110 NNL) NNL) Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions (Ibs), or *=PLF TCLL: 20.00 Wind Std: ASCE7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U /Rw /Rh /RL /W AP -126 /38 /58 /4 /239TCDL: 7.00 Speed: 140 mph Pf: NA Ce: NA VERT(LL): 0.163 AD 999 24C BCLL: o.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.435 AD 793 180 AQ 622 / 195 1313 /- /7.6 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.042 C - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.077 C AP Min Brg Width Req = - Code / Misc CriteriaNCBCLL: 10.00 Mean Height: 15.00 ft Creep Factor. 2.0 AQ Min Brg Width Req = 1.5 Soffit: 2.00 TCDL: 4.2 psf Bldg Code: FBC 2017 RES MaxTCCSI: 0.853 Bearings AP & AQ are a rigid surface. Load Duration: 1,25 BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.745 Bearing AQ requires a seat plate. Spacing: 24.0 C&C Dist a: 4.00 ft Rep Factors Used: Yes Max Web CSI: 0.514 Members not listed have forces less than 375# Loc. from endwall: not in 6.50 ft FT/RT:0(0)/O(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0. 18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. VIEW Ver'. 17.02.01A.1114.21WindDuration: 1.60 WAVE Lumber Top chord 2x4 SP #1 Dense :T4, T5 2x4 SP #2 Dense: Bot chord 2x4 SP #1 Dense :132 2x4 SP #2 Dense: Webs 2x4 SP #3:W2 2x4 SP #1 Dense: W3, W4 2x4 SP #2 Dense: Bracing a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS; with additional C&C memberdesign. Additional Notes See DWGS A14015ENC101014 & GBLLETIN01 18 for gable wind bracing and other requirements. B -C 475 -1065 K -N 858 -227 B -AP 368 -628 N -P 263 -655 C -D 482 -1047 P-0 519 -1145 D -E 510 -1024 Q -R 533 -1174 F -H 472 -134 AQ- R 791 -918 H -K 414 -67 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. unarus I eris. Uomp. B -AC 1030 -416 T -R 1109 -420 AC -AB 934 -365 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. E -AS 683 -1454 K -U 320 -787 H -X 365 -833 U -N 446 -1066 X -K 522 -222 N -T 701 -201 X_U 417 -790 T -P 354 -567 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. AS 416 -174AC- E 494 -240 - F 0;. 7ATE OF L 0 RVIQ X: 0 278 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, sh ping, installing and bracing. Refer to and follow the latest edition of BCS1 (BuildingComponentSafetyInformation, by TPI an SBCA) or sa ety practices pHor to performing these functions. Installers shall provide temporary bracing er BCSI. Unless noted citherwise,top chord shall have fattached structural sheathing and bottom chord §hall have a propefl attacheSid ceilin,?,. Locations shown forpermanent lateral re= webs shall have bracinp inslalled per BCSI sections B3 B7 or 131Vasapplicabe. App y tes to each face of truss and position as shown above and on the Join Details, unless noted otherwis6. Refer to drawings 160A -Z fbr sCrdard plate positions. Alpine, a division of ITW Buildi ALPINE tr.. hComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the wing or cove 6750 Forum DdvesinconformancewithANSIPI1, or for handlinj shippiny, installation and bracing of trussesA seal on this dra ' P AN M COMPANY listing this Prawin , inqica s accegVnce 9f pro) ession engineering responsibility solely for the design shown. The '..flTbilityanduseothisgrawing ?.r any s cture is me responsAibilitg of the uilding Designer per ANSUTPI I Sec.2. Suite 305 For more information see this ob's general notes Pge and these mb sites: ALPINE: .alpineitw.com; TPI: Aptnst.org; SBCA: .sbdndustry.com; ICC: J afe.org Orlando FL, 32821 0 Job Number: 21218 UI3 10, 10 ply:: 1 7"10 6'4"10 9 5"; FTI 10 SEQN: 142674 T6 / COMN Cust: R408 JRef: 1 Wce4080005 Cascadia Home /Cascadia Home -MILLER CONSTRUCTION Loading Criteria (psf) Qty 6 Snow Criteria (Pg.Pf in PSF) FROM: JB A Maximum Reactions (lbs) OR. DrwN 186.18.0952.16285 Truss Label: A02 WindStd: ASCE7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc; Udefl L/# Loc R / U /Rw /Rh /RL W TCDL: 7.00 Speed: 140 mph KM WHK 07/05/2018 VERT(LL): 0.836 P 572 240 S 1572 / 482 / 709 /75 7.6 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 2.235 P 311 180 T 1558 / 478 /720 / - 7.6 BCDL: 10 00 Risk Category: 11 4 20''. 6 4. 60:, J: g6: i 6 117 4 io 12 67 1'qO:"6 10 NCBCLL: 10.00 Mean Height: 15 ' 00 ft Code / Misc Criteria 8X16 T Min Big Width Req = 1.6 Soffit: 2.00 TCDL: 4.2 psf Bldg Code: FBC 2017 RES F Bearings S & T are a rigid surface. Load Duration: 1.25 12 3 1112X4 T2 E Max BC CSI: 0.961 Bearings S & T require a seat plate. 3X4 G Spacing: 24.0 C&C Dist a: 4.00 ft 3X4 Max Web CSI: 0.947 a Loc. from endwall: not in 6.50 ft FT/RT:0(0)/O(0) 5X8 IRS) D Ply (Ibs) GCpi: 0. 18 Plate Type(s): 5X65XHt- 3X8 Tens. Cornp. Wind Duration: 1.60 WAVE, HS VIEW Ver: 17.02.01A.1114.21 1X6'B7R) B T1 B -C 2164 -6235 F -G z-: 3X4 Lumber A C -D 2568 -7347 G -H N W6 j K 1564 -4359 32 2x6 SP #2: 7_12 Q E -F 2646 -7Z71 I -J 1559 -4387 Bot chord 2x4 SP #1 Dense:131 2x6 SP SS: R 3X4 E Webs 2X4 SP #3:W5 2x4 SP #1 Dense: e' S B 1 W6, W7 2x4 SP #2 Dense: B2 M L Chords Tens.Comp. Chords Tens. Comp. Rt Slider 2x4 SP #3: BLOCK LENGTH = 1.935' POH0912 6X10 5X6 5X8(El) Lt Wedge 2x4 SP #3: 1.5 1112X4 B -R 6024 -2038 M -L 3596 -1241 12 R -Q 6165 -2086 L -J 4186 -1460 Bracing 1112X4 a) Continuous lateral restraint equally spaced on 40' g'4; 519.. UI3 10, 10 1'4 7"10 6'4"10 9 5"; FTI 10 1 2'0' 39 40' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg.Pf in PSF) Defl/CSI Criteria A Maximum Reactions (lbs) TCLL: 20.00 WindStd: ASCE7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc; Udefl L/# Loc R / U /Rw /Rh /RL W TCDL: 7.00 Speed: 140 mph Pf: NA Ce: NA VERT(LL): 0.836 P 572 240 S 1572 / 482 / 709 /75 7.6 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 2.235 P 311 180 T 1558 / 478 /720 / - 7.6 BCDL: 10 00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.222 L - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.407 L S Min Brg Width Req = 1.8 NCBCLL: 10.00 Mean Height: 15 ' 00 ft Code / Misc Criteria Creep Factor: 2.0 T Min Big Width Req = 1.6 Soffit: 2.00 TCDL: 4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.815 Bearings S & T are a rigid surface. Load Duration: 1.25 BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to In TPI Std: 2014 Max BC CSI: 0.961 Bearings S & T require a seat plate. Spacing: 24.0 C&C Dist a: 4.00 ft Rep Factors Used: Yes Max Web CSI: 0.947 Members not listed have forces less than 375# Loc. from endwall: not in 6.50 ft FT/RT:0(0)/O(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0. 18 Plate Type(s): Chords Tens.Comp. Chords Tens. Cornp. Wind Duration: 1.60 WAVE, HS VIEW Ver: 17.02.01A.1114.21 B -C 2164 -6235 F -G 1144 -2985 Lumber C -D 2568 -7347 G -H 1430 -4040 Top chord 2x4 SP #2 Dense:T1 2x4 SP #1 Dense: D -E 2652 -7429 H -I 1564 -4359 32 2x6 SP #2: E -F 2646 -7Z71 I -J 1559 -4387 Bot chord 2x4 SP #1 Dense:131 2x6 SP SS: 132 2x4 SP #2 Dense: Webs 2X4 SP #3:W5 2x4 SP #1 Dense: Maximum Bot Chord Forces Per Ply (Ibs) W6, W7 2x4 SP #2 Dense: Chords Tens.Comp. Chords Tens. Comp. Rt Slider 2x4 SP #3: BLOCK LENGTH = 1.935' Lt Wedge 2x4 SP #3: B -R 6024 -2038 M -L 3596 -1241 R -Q 6165 -2086 L -J 4186 -1460 Bracing Q -N 7285 -2457 a) Continuous lateral restraint equally spaced on member. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Wind Wind loads based on MWFRS with additional C&C R -C 232 -587 N -M C -Q 1092 M -G 2705 -887 350 -845 memberdesign. 362 N -F 4661 1648 G -L 533 -75 J, fikT E 0 278 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, sh ping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponentSafetyInformation, by TPI an SBCA) or sa ety practices pHor to performing these functions. Installers shall provide temporary bracingser BCSI. Unless noted citherwise,top chord shall have etio attached structural sheathing and bottom chord shall have a prDpeflpro 0 attache rigid ceiliny,. Locations shown forpermanent lateral retrapin f webs shall have bracinp installed per BCSI sections B3 B7 or 1313asapplicabe. App y tes to each face of truss and position as shown above and on the Join Details, unless noted otherwis6. kefer todrawings160A -Z fbr st rdard plate positions. Alpine, a division of ITW Buildi ALPINE trus nhComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN 1 COMPANY s in conformance with ANSI PI 1, or for handli4 shippiny, installation and bracing bf trussesA seal on this dravving or covelistingthisdrawing, indicates accg nce 9f pro) essiona r 6750 Forum Drive e nfet in responsibility solely for the design shown. The spi'Mility and use of this rawing for any a cture is the respominbIVo heMilding Designer per ANSI/TPI I Sec.2. Suite 3054 For more infomation see this job's general notes page and 1hese web sites* ALPINE: .alpineitwcorn; TPI: .tpinstorg; SBCA: www.sbcindustry.com; ICC: Jccsafe.org Orlando FL, 32821 4 Job Number: 21218 ply:: 1 SEQN: 959640 / T4 / COMI Cust: RR408. 1 JRef* IWGe4080005 Cascadia Home /Cascadia Home -MILLER CONSTRUCTION Qty 11 FROM: JB DrwNo: 186 8.1543.00309 Truss Label: A03 KM / OF 07/05/2018 1 10'4"3 4 5'4"5 12 5X6 D 3X4 11 3X8 Z—-5XB(137R) C B A R A- 2 S 4X4 T 1112X4 1.5 12 15'3"2 1 20:. 4'10"14 14 3X4 5x6r 1) E T2 P Q 8X8 H0912 417 ' T'i 1 2972 3 '6"2 40: i 4 7'j 4 4.. 65'14 3X6 G 1112X4 6x(5 1 3X4 j T4 W10 N 11 K L 0 M U, 1[12X4 B4 --5X8(El) 3X10 NE O t 0 278'%; S/0 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANr* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS russesreq re extreme care in fabricating, handli% sh ping, inptalling.and bracing. Refer to and follow the latest edition of BCSI (Building omponent Safety Information, by TPI an SBCA) or sa Ety practices prior to performing these functions. Installers shall provide temporary bracing er BCSI. Unless noted otherwise,top chord shall have property attached structural sheathing and bottom chord shall have a progeny attache 6 id ceilin . Locations shown for permanent lateral restraint of webs shall have bracinp installed per BCS1 sections B3, 137 orsapp, a ap lica e. Appy e each face of truss and position asshownaboveand on the Join Details, unless noted otherwise. eferlto' ' AA4, drawings 160A -Z for sgantdasrdtoplate positions. Alpine, a division of ITW Buildi,$Components Group Inc. shall not be responsible for any deviation from this drawing,apy failure to build the ALPINE truss in conformance with ANSI PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawling or cover p AN rrW COMPANY listing this drawing, indicates acceptance 9f prOTessional . ee . ar 6750 Forum Driveerfiringuresponsibilitysolelyforthedesgpnshown. The sui bilityIWotaanduseofthisrarwingforanyaructureistheresponsibheildingDesigrierperANSUTPIIec.2. Suite 305 or mom information see this job's general notes page and these web sites: ALPINE: .alpineitwxom; TPI: www.tpinst.org; SBCA: .sbdndustrycom: ICC. Jccsafe.org Orlando FL, 32821 1 4r " 47-9 1 57"13 40' 14 1 9'-0"6 42 7:'8 1 1'4; 4'10"3 10 T.10 2 211- 1 34 4' 0 Loading Criteria (ps Wind Criteria Snow Criteria (Pg,Pf in PSF) DefVCSI Criteria A Maximum Reactions (lbs) TCLL: 20.00 Wind Std: ASCE7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U /Rw /Rh /RL 1W TCDL 7.00 Speed: 140 mph Pf: NA Ce: NA VERT(LL): 0.931 P 513 240 T 1571 / 481 /709 /73 7.6 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 2.493 P 279 180 U 1558 /476 /720 /- 7.6 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.310 M - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.570 M T Min Brg Width Req = 1.8 NCBCLL: 10-00 Mean Height: 15.00 ft Code / Misc Criteria Creep Factor: 2.0 U Min Brg Width Req = 1.6 Soffit: 2.00 TCDL: 4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.924 Bearings T & U are a rigid surface. Load Duration: 1.25 BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to In TPI Std: 2014 Max BC CSI: O 943 Bearings T & U require a seat plate. Spacing: 24.0 C&C Dist a: 4.00 ft Rep Factors Used: Yes Max Web CSI: 0.900 Members not listed have forces less than 375# Loc. from endwall: not in 6.50 ft FT/RT:0(0)/O(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0. 18 Plate Type(s): Chords Tens.Comp. Chords Tens. Curnp Wind Duration: 1,60 WAVE, HS VIEW Ver: 17.02.01A.1 115.21 B -C 2023 -5846 G -H 2767 -7833 Lumber C -D 2458 -7072 H - 1 2693 -7706 Top chord 2x4 SP #1 Dense :T2, T4 2x4 SP #2 D -E 2273 -6390 I -J 1503 -4294 Dense: E - F 1 929 -5422 J -K 1 500 -4323 Bot chord 2x6 SP SS B4 2x4 SP #2 Dense: F -G 1923 -5423 Webs 2x4 SP #3:Wl 0, W1 1, W1 2 2x4 SP #2 Dense: Rt Slider 2x4 SP #3: BLOCK LENGTH = 1.935' Lt Wedge 2x4 SP #3: Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Wind B -S 5634 -1902 Q -P 6196 -2071 Wind loads based on MWFRS with additional C&C S -R 5750 - 942 P -N1 6410 -2200 memberdesign. R -Q 6892 -2314 M -K 4121 -1402 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. S -C 209 -494 P -G 533 -1206 1151C - R -374 G -N 1406 -449 D -Q 251 -684 N -M E -P 416 -959 N - F -P 2363 -770 M - 4120 -1395 3362 - 11131 522 - 376 NE O t 0 278'%; S/0 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANr* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS russesreq re extreme care in fabricating, handli% sh ping, inptalling.and bracing. Refer to and follow the latest edition of BCSI (Building omponent Safety Information, by TPI an SBCA) or sa Ety practices prior to performing these functions. Installers shall provide temporary bracing er BCSI. Unless noted otherwise,top chord shall have property attached structural sheathing and bottom chord shall have a progeny attache 6 id ceilin . Locations shown for permanent lateral restraint of webs shall have bracinp installed per BCS1 sections B3, 137 orsapp, a ap lica e. Appy e each face of truss and position asshownaboveand on the Join Details, unless noted otherwise. eferlto' ' AA4, drawings 160A -Z for sgantdasrdtoplate positions. Alpine, a division of ITW Buildi,$Components Group Inc. shall not be responsible for any deviation from this drawing,apy failure to build the ALPINE truss in conformance with ANSI PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawling or cover p AN rrW COMPANY listing this drawing, indicates acceptance 9f prOTessional . ee . ar 6750 Forum Driveerfiringuresponsibilitysolelyforthedesgpnshown. The sui bilityIWotaanduseofthisrarwingforanyaructureistheresponsibheildingDesigrierperANSUTPIIec.2. Suite 305 or mom information see this job's general notes page and these web sites: ALPINE: .alpineitwxom; TPI: www.tpinst.org; SBCA: .sbdndustrycom: ICC. Jccsafe.org Orlando FL, 32821 Job Number: 21218 ply:: I SEQN: 959741 T9 GABL Cust: R408 JRef: 1Wce4080005 Cascadia Home /Cascadia Home -MILLER CONSTRUCTION City 1 FROM: JB DrwNo: 186.18.0952.16392 Truss Label: A04 KM / DF 07/05/2018 Z6"9 32' 36' q38.. "2 1-3711'21'14 4'11"15 10.1-8 15'3"2 20' 45"&10 29'2"5 3 Z 33'1 "A 3T 140' l 7 _ 1'3'11 2-61' 511,19 5111,10 4'8"14 4 4'8"l 1 '9'l V1 0'4 V5 115,14 40' g'4 47-10 571 11,110 2' 2' 4' 1 1A 10 4'10"4 1010.. 1 M 36' 40' 7" 11 14'11"10 26 29'016 2' H710 l`73 1 NNL) (NNL) 4-- -- 4' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defil/CSI Criteria A Maximum Reactions (Ibs), or *=PLF TCLL: 20.00 Wind Std: ASCE7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U /Rw /Rh /RL /W TCDL: 7.00 Speed: 140 mph Pf: NA Ce: NA VERT(LL): 0.517 E 680 240 AC -106 /33 /49 /7 /124 BCLL om Enclosure: Closed Lu: NA Cs: NA VERT(TL): 1.425 E 370 180 0' 186 56 /86 /131 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.136 T - - R /244 Des Ld: 37.00 EXP: C HORZ(TL): 0.250 T Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height: 15.00 ft Code I Misc Criteria Creep Factor: 2.0 AC Min Brg Width Req = - soffit: 2.00 TCDL: 4.2 psf Bldg Code: FBC 2017 RES MaxTCCSI: 0.886 0 MinBrgWidthReq= - BCDL: 5.0 psf Bearings AC & T are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.944 Spacing: 24.0 C&C Dist a: 4.00 ft Rep Factors Used: Yes Max Web CSI: 0.723 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:0(0)/O(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp Lumber Wind Duration: 1.60 WAVE, HS VIEWVer: 17.02.01A.1115.21 B -C 2003 -5049 F -G 829 -2179 B -AC 1503 -3623 G -H 820 -2174 Top chord 2x4 SP #2 Dense C -D 2008 -5031 H - 1 1724 -530 Bot chord 2x4 SP #1 Dense:B3, B4 2x4 SP #2 D -E 778 -4752 1 - L 977 -261 Dense: 1 Webs 2x4 SP #3 :W1 0 2x6 SP SS: E -F 1310 -3503 Bracing Maximum Bot Chord Forces Per Ply (Ibs) a) Continuous lateral restraint equally spaced on Chords Tens.Comp. Chords Tens. UU[TIP. member. B -Y 4901 -1908 W -V 3351 -1104 Plating Notes Y_X 4951 -1930 V -U 1181 -396 All plates are 2X4 except as noted. X -W 4591 -1616 Wind Maximum Web Forces Per Ply (Ibs) Wind loads based on MWFRS with additional C&C Webs Tens.Comp. Webs Tens. Comp. memberdesign. E -W 504 - 1204 V -H 969 -257 Additional Notes W -F 438 -145 H -U 1175 -3160 See DWGS A14015ENC101014 8, GBLLETIN01 18 for F -V 543 -1286 U -T 607 -1694 G -V 773 -231 T -L 239 -664 gable wind bracing and other requirements. Shim all supports to solid bearing. iflA T E 6: 6 0 278 - IVAL ki:t toomemoso 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANr* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, sh' ' ' istalling and bracing. Refer to and follow the latest edition of BCSI (BuildingTping, ir eComponentSafetyInformation, by TPI an SBCA) or sa ety practices phor to performing these functions. Installers shall provide temporary bracingser BCSI. Unless noted otherwise,top chord shall have property attached structural sheathing and bottom chord shall have a propedy attache rigidceiliny,. Locations shown for permanent lateral restraint 6f webs shall have brja.c np inslalled per BCS I sections P3,. B7 or 6 10, 3 Refer toasapplicabe. App y tes to each face of truss and position as shown above and on the in Details, unless noted otherwise drawings 160A -Z fbr st rdard plate positions. Alpine, a division of ITW Buildi ALPINE rhComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN M COMPANY truss in conformance with ANSI P1 1, or for handlin% shippiny, installation and bracing of trussesA seal on this drawing or coverspalistingthisdrawing, indicates acceptance 9f pro) essiona engmeen g responsibility solely for the design shown. The , Nbility 6750 Forum Drive and use of this rawing for any structure is the responstibilitg of the uilding Designer per ANSI/TPI 1 Sbc.2. Suite 305 For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPL Apinstorg; SBCA: www.sbcindustry.com; ICC: Jccsafe.org Orlando FL, 32821 5X6 12 G 3 co 3X4 z–z 4X6 HO510FH 1115X65X6 5X8 a , a I E 3X4V3X45 L 3 C D v 3X4 T X4 B A w 5x8 B3Xii 5X65X60 P3X4U AA, CWO _H0510 1.5 T1113X6 R 12 134 3X4 40' g'4 47-10 571 11,110 2' 2' 4' 1 1A 10 4'10"4 1010.. 1 M 36' 40' 7" 11 14'11"10 26 29'016 2' H710 l`73 1 NNL) (NNL) 4-- -- 4' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defil/CSI Criteria A Maximum Reactions (Ibs), or *=PLF TCLL: 20.00 Wind Std: ASCE7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U /Rw /Rh /RL /W TCDL: 7.00 Speed: 140 mph Pf: NA Ce: NA VERT(LL): 0.517 E 680 240 AC -106 /33 /49 /7 /124 BCLL om Enclosure: Closed Lu: NA Cs: NA VERT(TL): 1.425 E 370 180 0' 186 56 /86 /131 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.136 T - - R /244 Des Ld: 37.00 EXP: C HORZ(TL): 0.250 T Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height: 15.00 ft Code I Misc Criteria Creep Factor: 2.0 AC Min Brg Width Req = - soffit: 2.00 TCDL: 4.2 psf Bldg Code: FBC 2017 RES MaxTCCSI: 0.886 0 MinBrgWidthReq= - BCDL: 5.0 psf Bearings AC & T are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.944 Spacing: 24.0 C&C Dist a: 4.00 ft Rep Factors Used: Yes Max Web CSI: 0.723 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:0(0)/O(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp Lumber Wind Duration: 1.60 WAVE, HS VIEWVer: 17.02.01A.1115.21 B -C 2003 -5049 F -G 829 -2179 B -AC 1503 -3623 G -H 820 -2174 Top chord 2x4 SP #2 Dense C -D 2008 -5031 H - 1 1724 -530 Bot chord 2x4 SP #1 Dense:B3, B4 2x4 SP #2 D -E 778 -4752 1 - L 977 -261 Dense: 1 Webs 2x4 SP #3 :W1 0 2x6 SP SS: E -F 1310 -3503 Bracing Maximum Bot Chord Forces Per Ply (Ibs) a) Continuous lateral restraint equally spaced on Chords Tens.Comp. Chords Tens. UU[TIP. member. B -Y 4901 -1908 W -V 3351 -1104 Plating Notes Y_X 4951 -1930 V -U 1181 -396 All plates are 2X4 except as noted. X -W 4591 -1616 Wind Maximum Web Forces Per Ply (Ibs) Wind loads based on MWFRS with additional C&C Webs Tens.Comp. Webs Tens. Comp. memberdesign. E -W 504 - 1204 V -H 969 -257 Additional Notes W -F 438 -145 H -U 1175 -3160 See DWGS A14015ENC101014 8, GBLLETIN01 18 for F -V 543 -1286 U -T 607 -1694 G -V 773 -231 T -L 239 -664 gable wind bracing and other requirements. Shim all supports to solid bearing. iflA T E 6: 6 0 278 - IVALki:t toomemoso 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANr* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, sh' ' ' istalling and bracing. Refer to and follow the latest edition of BCSI (BuildingTping, ir eComponentSafetyInformation, by TPI an SBCA) or sa ety practices phor to performing these functions. Installers shall provide temporary bracingser BCSI. Unless noted otherwise,top chord shall have property attached structural sheathing and bottom chord shall have a propedy attache rigidceiliny,. Locations shown for permanent lateral restraint 6f webs shall have brja.c np inslalled per BCS I sections P3,. B7 or 6 10, 3 Refer toasapplicabe. App y tes to each face of truss and position as shown above and on the in Details, unless noted otherwise drawings 160A -Z fbr st rdard plate positions. Alpine, a division of ITW Buildi ALPINE rhComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN M COMPANY truss in conformance with ANSI P1 1, or for handlin% shippiny, installation and bracing of trussesA seal on this drawing or coverspalistingthisdrawing, indicates acceptance 9f pro) essiona engmeen g responsibility solely for the design shown. The , Nbility 6750 Forum Drive and use of this rawing for any structure is the responstibilitg of the uilding Designer per ANSI/TPI 1 Sbc.2. Suite 305 For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPL Apinstorg; SBCA: www.sbcindustry.com; ICC: Jccsafe.org Orlando FL, 32821 Job Number: 21218 Ply: 1 SEQN: 959646 1- R408 JRef: 1Wce4080005 Cascadia Home /Cascadia Home -MILLER CONSTRUCTION Qty FROM: JB No: 186.18.0952.16455 Truss Label; A05 / DF 07/05/2018 410'4"3 153 211::15 5'4"5 41'0""24 T l 4 441'71 1' 1 4X4G 3X4 12 F H 5X6 1112X4 E 3X4 a) 3X6 D M5X8 B3C N B A 0 3X4 ... 12 P _ 5x6 1113X6(E3) if2X4 — 1.5 1114X6 3X4(E3) 12 1 29'74 411 47-9 4 6 9'3"12 1'4"12 04'10"3 1 0 11 3 4 1!1 2'6' 29'3"12 8 7; 0 .74 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions (lbs) TCLL: 20.00 WindStd: ASCE7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R / U /Rw /Rh /RL /W TCDL: 7.00 Speed: 140 mph Pf: INA Ce: NA VERT(LL): 0.415 E 851 240 B 1173 /358 /541 /117 /7.6 BCLL: 0.00 Enclosure: Closed Lu: INA Cs: INA VERT(TL): 1.105 E 465 180 K 1189 /369 /534 /- /6.9 BCDL: 10.00 Risk Category: 11 Snow Duration: INA HORZ(LL): 0.131 L - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.240 L B Min Brg Width Req = 1.5 NCBCLL: 10.00 Mean Height: 15.00 ft Code / Misc Criteria Creep Factor: 2.0 K Min Brg Width Req = 6.9 Soffit: 2.00 TCDL: 4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.792 Bearings B & K are a rigid surface. BCDL: 5.0 psf Bearings B & K require a seat plate. Load Duration: 1.25 MWFRS Parallel Dist: 0 to h12 TPI Std: 2014 Max BC CSI: 0.912 Spacing: 24.0 C&C Dist a: 3.00 It Rep Factors Used: Yes Max Web CSI: 0.828 Members not listed have forces less than 375# Loc. from endwall: Any FT/RT:0(0)/O(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEWVer: 17.02.01A.1115.21 Lumber B -C 2556 -4300 E -F 2306 -3646 C -D 2537 -4257 F -G 1647 -2563 Top chord 2x4 SP #2 Dense D -E 2724 -4500 G -H 1662 -2563 Bot chord 2x4 SP #1 Dense :B3 2x4 SP #2 Dense: Webs 2x4 SP #3 Lt Slider 2x4 SP #2 Dense: BLOCK LENGTH = 2.757' Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Chords Tens. UQUIP. Bracing B -P 4090 -2504 N -M 3503 -2163 a) Continuous lateral restraint equally spaced on P-0 4121 -2528 M -L 1929 -1241 member. O -N 4366 -2668 Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply (Ibs) member design. Webs Tens.Comp. Webs Tens. Comp. Right end vertical not exposed to wind pressure. E -N 516 -848 G -M 973 -520 Drop leg not designed to support lateral loads from IN - F 376 -179 H - L 1477 -2219 wall enduced by wind. Provisions must be made to resist F -M 741 -1074 L -K 875 -1188 lateral loads from wall. Building designer must approve M -H 588 -291 prior to fabrication. e 40 0 278 101YAL 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponentSafetyInformation, by TPI an SBCA) or sa ety practices prior to performing these functions. Installers shall provide temporary bracing er BCSI. Unless noted o1herwise,top chord shall have properly attached structural sheathinq and bottom chord shall have a progedy aftachef n ' 'd 'I' Locations shown for permanent lateral restraint 6f webs shall have bracinp installed per BCSI sections B3 B7 or 10as applicab9lec. CeAlpin p,T gates to each face of truss and position as shown above and on the Join Details, unless noted otherwis6. kefer to' rdrawings160A -Z fbr s ndard plate positions. Alpine, a division of ITW Buildi ALPINE Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN N`W COMPANY truss in conformance with ANSI PI 1, or for handIA shippiny, installation and bracing of trussesA eal on this draviting or cove 6750 Forum Drivelistingthisdrawing, indicates acceptance 9f proession engineering responsibility solely ?or the design shown. The rspiMbilityanduseofthisrawingforanyaructureistherespons;kibilitg ofthe uilding Designer per ANSIITPI 1 Sec.2. Suite 305r For more information see this job's general notes page and these mb sites: ALPINE: .alpineitw.corn; TPI: Jpinst.orq: SBCA: www.sbcindustry.com; ICC: Accsafe.org Orlando FIL, 32821 a Job Number: 21218 ply:: I SEQN: 959737 1 T8 / GABIL Cust: R R408. 1 JRef: 1 Woe4080005 Cascadia Home /Cascadia Home -MILLER CONSTRUCTION Qty 1 FROM: JB DrwNo: 186 8.1543.00278 Truss Label: A06 KM / OF 07/05/201 T QlCI A L C 3 T_Wil I 1' 2 2; WG 2f"' 7' 217 U,1511-161:1 31 0 4 1 14P910 T 4X4 4-2-9 3X4 I 7X8 --7XB N3X6(--) 3 G 3X4 SC2 X' 3>4 L UX6:0X142(R) 3,X8 Nol 1 5 W(R) w 1-2 F 9 16' 1 479 1-1134_: Itl 4-11-1 NNQ 5W Loading Criteria (psri Wind Criteria TCLL: 20-00 Wind Std: ASCE7-110 TCDL: 7.00 Speed: 140 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: 11 EXP: C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 2.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 C&C Dist a: 3.00 ft Loc. from endwall: Any GC pi: 0. 18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Filler 2x4 SP #2 Dense Stack Chord SC1 2x4 SP #2 Dense: Stack Chord SC2 2x4 SP #2 Dense: Lt Slider 2x4 SP #3: BLOCK LENGTH = 3.426' Plating Notes All plates are 2X4 except as noted. 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins Laterally brace BC at 24" oc in lieu of rigid ceiling. Laterally brace BC above filler at 24" oc. Wind Wind loads based on MWFRS; with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes See DWGS A14015ENC101014 & GBLLETIN01 18 for gable wind bracing and other requirements. Stacked top chord must NOT be notched or cut in area (NNL). Attach stacked top chord (SC) to dropped top chord in notchable area using 3x4 tie -plates 24" oc. Center plate on stacked/dropped Q J :::::!a M 3X6 5X8 + 4X, 5X6 2974 20!" 12 29712 NNQ 54" T Snow Criteria (Pg,Pf in PSF) Defi/CSI Criteria A Maximum Reactions (Ibs), or *=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl L/# Loc R / U /Rw /Rh /RL /W Pf: NA Ce: NA VERT(LL): 0.040 W 999 240 AO -80 /25 /35 /- /4 /355 Lu: NA Cs: NA VERT(TQ: 0.107 W 999 180 Wind reactions based on MWFRS Snow Duration: NA HORZ(LL): 0.008 D AO Min Brg Width Req = - HORZ(TL): 0.015 D Bearing AO is a rigid surface. Code / Misc Criteria Creep Factor: 2.0 Bearing AO requires a seat plate. Bldg Code: FBC 2017 RES Max TC CSI: 0.351 TPI Std: 2014 Max BC CSI: 0.500 Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Rep Factors Used: Yes Max Web CSI: 0.413 Chords Tens.Comp. Chords Tens. Comp. FT/RT:0(0)/O(0) Plate Type(s): 01A.1115.21 B -C 617 -479 C -D 635 -463 WAVE Fy Laterally brace BC above filler @ 24" O.C. (or as Maximum Bot Chord Forces Per Ply (Ibs) designed) Including a brace on BC directly above Chords Tens.Comp. Chords Tens. Comp. both ends of filler (if no rigid diaphragm exists at B -W 470 -567 V -U 440 -538 that point) W -V 475 -571 Member to be laterally braced for horizontal wind load. Bracing system to be designed and Maximum Web Forces Per Ply (Ibs) furnished by others. Webs Tens.Comp. Gable -end profile does not match that of adjacent D -U 741 -567truss. Building designer is responsible for designing and providing adequate bracing. 7ATE 0 WD X48 chord interface, plate length perpendicular to chord #02 8 length. Splice top chord in notchable area using 3x6. 07/05/, WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, sh ping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponentSafetyInformation, by TPI an SBCA) or sa ety practices phor to performing these functions. Installers shall provide temporary bracingyer BCSI. Unless noted citherwise,top chord shall have propedy attached structural sheathing and bottom chord shall have a progerly aft h id iIi Locations shown for permanent lateral restraint of webs shall have brJa0c np installed per BCS] sections B3 B7 or 10acne' n ' 'in a. applicaMe. 'Ap Details, unless noted otherwis6. kefer to' p? plates to each face of truss and position as shown above and on the in drawings 160A -Z fbr standard plate positions. ALPINE Alpine, a division of ITW Buildi%omponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN ITW COMPANY russ in conformance with ANSI PI 1, or for handlia shipping, instpilatiqn and bracing of trussesA seal on this drawing or cover pa et essional engmeenn responsibility solely for the design shown. The sulabilitylistingthisdrawin , indicates accentance of pro), 6750 Forum Drive and use of this gram - . rucit re is the responsibilitg of the guild Ing Designer per ANSI/TPI 1 Sec.2. Suite 305 For more info ation see this IOUs general notes page and these web sites: ALPINE: alpineitwxom; TPI: wwwApinst.org; SBCA: .sbcindustry.com; ICC: Jccsafe.org Orlando FL, 32821 Job Number: 21218 ply:: 10 SEQN: 142723 / T1 / COMN Cust: R R408. 1 JRef: 1 Wce408OOO5 Cascadia Home /Cascadia Home -MILLER CONSTRUCTION Qty 1 FROM: JB DrwNo: 186 8.0952.16284 Truss Label: B01 KM / WHK 07/05/2018 I 6'10"B 6'10"8 10'4" 39"8 20'8" 3'5"8 13,5"8 6'10"8 04 12 D 20'8" M, 1113 1,0% VATE OF 1"Q: 0 278 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANr* FU RNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponentSafetyInformation, by TPI an SBCA) or sa ety practices pHor to performing these functions. Installers shall provide temporary bracingyer BCSI. Unless noted olherwise,top chord shall have property attached structural sheathing and bottom chord shall have a property attache rigid ceiliny,. Locations shown for permanent lateral restraint of webs shall have brja0c, 'np installed per BCSI sections P3,.B7 or B10, as applicab a. App y plates to each face of truss and position as shown above and on the n Details, unless noted otherwise kefer to drawings 160A -Z fbr standard plate positions. ALPINE Alpine, a division of ITW Buildi Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN COMPANY truss in conformance with ANSI PI 1, or for handlia shippin, installation and bracing of trussesA seal on this drawing or cover 6750 Forum Ddve listing this drawing, indicates acceptance 9f proessiona engin ign shown. The P.Stilityyjerigresponsibilitysolelyforthecles: and use of this rawing tor any structure is the responstibilitg o the uilding Designer per ANSI1TP1 I Sec.2. Suite 305 lFor more infonmation see this job's general notes page and these web sites: ALPINE: .alpineitw.com; TPI: Apinst.org; SBCA: .sbdndustry.corn; ICC: J safe.org Orlando FL, 32821 1 9'10"4 9'10"4 - 1'4" 1'4" 2 2 10'4" 20'2"4 5"12 F20'8.. Loading Criteria (psf) Wind Criteria Snow Criteria PgRf in PSF) Defl/CSI Criteria A Maximum Reactions (lbs) TCLL: 20.00 Wind Std: ASCE7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U /Rw /Rh /RL 1W TCDL: 7.00 Speed: 140 mph Pf: NA Ce: NA VERT(LL): 0.088 H 999 240 B 845 / 261 /389 /40 /7.6 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.232 H 999 180 1 845 /261 /389 / - /7.6 BCDL: lo.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.024 H - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.043 H B Min Brg Width Req = 1.5 NCBCLL: 10.00 Mean Height: 15.00 ft Code / Mise Criteria Creep Factor: 2.0 1 Min Brg Width Req = 1.5 Soffit: 2.00 TCDL: 4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.527 Bearings B & I are a rigid surface. Load Duration: 1.25 BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.811 Bearings B & I require a seat plate. Spacing: 24.0 C&C Dist a: 3.00 ft Rep Factors Used: Yes Max Web CSI: 0.222 Members not listed have forces less than 375# Loc. from endwall: Any FT/RT:0(0)/O(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.01A.111411 B -C 1252 -1850 D -E 996 -1476 Lumber C -D 995 -1476 E - F 1252 -1850 Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #1 Dense Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Lt Stub Wedge 2x4 SP 3::Rt Stub Wedge 2x4 SP #3: Chords Tens.Comp. Chords Tens. uornp. B-H 1742 -1135 H -F 1742 -1141 Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply (Ibs) member design. Webs Tens.Comp. Webs Tens. Comp. C -H 393 -395 H -E 393 -395 D -H 583 -311 M, 1113 1,0% VATE OF 1"Q: 0 278 07/05/2018 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANr* FU RNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponentSafetyInformation, by TPI an SBCA) or sa ety practices pHor to performing these functions. Installers shall provide temporary bracingyer BCSI. Unless noted olherwise,top chord shall have property attached structural sheathing and bottom chord shall have a property attache rigid ceiliny,. Locations shown for permanent lateral restraint of webs shall have brja0c, 'np installed per BCSI sections P3,.B7 or B10, as applicab a. App y plates to each face of truss and position as shown above and on the n Details, unless noted otherwise kefer to drawings 160A -Z fbr standard plate positions. ALPINE Alpine, a division of ITW Buildi Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN COMPANY truss in conformance with ANSI PI 1, or for handlia shippin, installation and bracing of trussesA seal on this drawing or cover 6750 Forum Ddve listing this drawing, indicates acceptance 9f proessiona engin ign shown. The P.Stilityyjerigresponsibilitysolelyforthecles: and use of this rawing tor any structure is the responstibilitg o the uilding Designer per ANSI1TP1 I Sec.2. Suite 305 lFor more infonmation see this job's general notes page and these web sites: ALPINE: .alpineitw.com; TPI: Apinst.org; SBCA: .sbdndustry.corn; ICC: J safe.org Orlando FL, 32821 Job Number: 21218 ply:: 1 SEQN: 142758 / T2 / GABL Cust, RR408 JRef: 1Wce4080005 Cascadia Home /Cascadia Home -MILLER CONSTRUCTION Oty 1 FROM: JB DrwNo: 186.18.0952.16330 Truss Label: B02 KM / WHK 07/05/2018 C4 7'12i _L Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 1000 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 2.00 Load Duration: 1.25 Spacing: 24.0 " 2'6"9 10-4" 2-6-9 T97 6-4" 2' -- 2 ( TYP) 4X4 F 18'1 "7 7-97 20-8" 2'6"9 V4" 5X6 i 2U8" NNL) 5'4" Wind Criteria Wind Std: ASCE7-10 Speed: 140 mph Enclosure: Closed Risk Category: 11 EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0. 18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Dense Bot chord 2x4 SP #2 Dense Webs 2x4 SP #3 Stack Chord SC1 2x4 SP #2 Dense: Stack Chord SC2 2x4 SP #2 Dense: Plating Notes Ail plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C memberdesign. Additional Notes See DWGS A14015ENC101014 & GBLLETIN01 18 for gable wind bracing and other requirements. Stacked top chord must NOT be notched or cut in area (NNL). Dropped top chord braced at 24" oc intervals. Attach stacked top chord (SC) to dropped top chord in notchable area using 3x4 tie -plates 24" oc. Center plate on stacked/dropped chord interface. plate length perpendicular to chord length. Splice top chord in notchable, area using 3x6. 298" 20-8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.056 1 999 240 Lu: NA Cs: NA VERT(TL): 0.148 1 999 180 Snow Duration: NA HORZ(LL): 0.013 C - - HORZ(TL): 0.024 C Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 2017 RES Max TC CSI: 0.405 TPI Std: 2014 Max BC CSI: 0.325 Rep Factors Used: Yes Max Web CSI: 0. 106 FT/RT:0(0)/O(0) Plate Type(s): WAVE VIEW Ver: 17.02.01A.1114.21 E", li,o% VATE OF 0 278NZN IV AL 07/05/2018 F1 V4" -1 NNL) 5-4" 8' A Maximum Reactions (lbs), or *=PLF Loc R / U /Rw /Rh /RL 1W J* 82 /25 /37 /- /2 /248 Wind reactions based on MWFRS J Min Brg Width Req = - Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply,(Ibs) Chords Tens.Comp. 1-1 379 -423 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. L -H 405 -329 WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! IMPORTANr* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinp, sh ping, installing and bracing. Refer to and follow the latest edition of BCS] (BuildingComponentSafetyInformation, by TPI an SBCA) or sa ety practices pHor to performing these functions. Installers shall provide temporary bracingTer.BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro erlyattacherigidceiliny. Locations shown forpermanent lateral restraint of webs shall have bracing installed per BCSI sections B3 B7 or 910asapplical5e. Appy tes to each face of truss and position as shown above and on the Joint Details, unless noted otherwis. kefer to' drawings 160A -Z fbr s9ardard plate positions. Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformance with ANSI PI 1, or for handlina. shiDDinci. installation and bracina bf trussesA seal on this drawing or cove Ing this drawing, indicaWs acceptanceJuseofthisrawingforanystructure more information see this job's general notes page ani TPI: Fri. The suitability ALPINE AN COMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 Gabte Stud Reinforcement Detait ASCE 7-10: 140 mph Wind Speed, 15' Mean Height, Enctoseol, ExposUre C, Kzt = 1.00 Or- 120 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt LOD Or- 120 mph WInd Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 n— inn -N %ji-j z -ml i-;, Ili— wetri,+ rri,ir.-4 n v_+ inn Bracing Group Species and Grades, Group A, Pruce- ne-Fir Hem -Fir 1 #1 / #2 IStandard 1 #2 1 Stu 1 #3 1 Stud 1 1 #3 IStand9ard Duo (is Fir -Larch Southern Plnewwls 3 #3 i—tual Stud Group B, Hen -Fir 1 ki Btr Dpuqlas Fir -Larch Southern Pinewsw 2 Ix4 Braces shall be SRB (Stpess-Rated BoaroD. 4wwFor lx4 So. Pine use only Industrial or Industrial 45 Stress -Rated Boards. Gr up B11valuesmaybeusedwiththesegrades. babLe Truss Detalt Notes: Wind Load deflection criterion Is L/240, Provide uplift connections for 55 ptf over continuous bearing (5 psf TC Dead Load), Goble end supports load from 4' V outtookers with 2' 0' overhang, or 12' plywood overhang. wl;;." i IY_ Attach ILI braces with 10d (0.12Wx3,0' min> nails. ble Truss X For Q> ILI brace. space nails at 2' oc. a In 18' end zones and 4' o.c. between zones, K)KFw (2) ILI braces. space malts at 3' o.c. Diagonal brace option, In 19' end zones and S' o.c. between zones. vertical length may be T doubted when diagonal is, 3K 'L' bracing must be a minimum of 80% of web brace Is useoL Connect member length. diagonal brace for 450# ILI J_ at each end, Max web Br ce Gable Vertical. Plate Sizes total length Is 14 K I Vertical Lenoth No SpliceWX 2x4 DF -L *2 or Less than 41 01 IX4 or 2X3 1Z better diagonal T_ iGreater than 4' 01 X4 I Vertical length shown brace) single in table above. 1451* or double cut )K as shown) at n I Irl 4 Refer to common truss design for upper end. l_i u "a] u -q u Ill V j'r IL_peaLk, splice, and heel plates. 77 7 4 1 / A Refer to the Building Designer for conditionsIng Connect d1agon.T_.t__ low not addressed by this detail. Refer to chart a4e a a e tp. amidpointofverticalwell. '44d WARNDX3- READ AND FOLLOW ALL NOTES ON TMS DMVING a, REF ASCE7-10—GABI4015DrORTANT— FURNISH TMS DRAWFINCi To ALL cowntAcTaws ucLullm ThE =TmLEM f Truss— require extreme car* In fabricatimil, ho"Imo, shipping, lnst*LLW* and braeft, Refer to I oil ow the Latest edition of SCSI (BuIllingi Component Safety Information, by TPI and SBCAi for s*ffty 0 DATE 10/01/14 or. formthil, these funi tlom Installers shalt provide temporary brachil per BC .16 untcxtsic&mstp ciborthteorwiWseI too chord sl how property attached st—twat ii W* and bottom we it hw property tt..hd IgW —Kini). Loc.tlom. shown fair p—mont L.t.ral ... train* of DRWG A14015ENC101014 shall have lor—InG installed per BCSI sect$ons 23, B7 or DID, as appilc6ble. Apply plates to ch f.c wiaMpositlonasshoemaboveamidontheJointDetails, unless no-ttal otherwise. LJPD [F Rf. 4,-t. d-shl l"A-Z far tandard plot. poisitions. 10A&N OR\)- Alpine, . alllWon of ITV B.Noing Components Group I- halt not be —ponsibl. far my t f 44 AN rrw CC`k4PAW this dr—kno, ary failure to bLAd the tr"s in conformance with ANSI/TPI 1, or far handling, aaawasiell"' Inst.1l.tion & birachv of t—sts. TOT. LD. 60 PSF 13723 Riverport Dr— . A wiral an this d -.*V or cliver PM listing this drawling, hx4diastirs .—ptamor of prof I f2M-6=ponsIkAIU.w==y d.% shown, = I= M and —,a* this dra Sui e 2DO t.— is f B.R*V =YxTPI SOC2. Maryland Heights, MO 63D43 For — Information see this, jobS general notes page and these web sites- ALPINE- —.1pheltwzomi TPI. wwwApinilt.o,ll) SBC& —..t1Clnds1ry—Q) Icc. -kCsaftoro 07/05/20 8 AX. SPACING 24.0' BBracerace Gabte Verticat Spacing ISpecies I Grade No Braces W Ix4 ILI Brace is Group A Group B 1) 2x4 ILI Brace 0 (2) 2x4 ILI Brace wis (1) 2x6 ILI Brace 9 l 2x6 ILI Brace its Group A Group B Group A Group B Group A Group B Group A Group B 0) SPF# 1 2 3' 7' 3' 7' 7' 8' 7' 81 111 10' 3' 10, a, 13, 61 14' 0' 14' 0' 14' 0' 3 4' V 6' 7' 7' 1- S' 6' 81 10, 10, 11 10' 6' 13' 4' 13' 10' 14' 0' 14' 0' U HF stud 41 11 6' 7' 71 0' 8' 61 81 10, 10, 11 10, 61 13' 4' 131 10- 141 0' 14' 0' C 0 Standard 4' V 5, e, 6' 0' 7' 7' 81 11 10, 11 10' 61 111 10, 12' 81 14' D' 14' 0' 0) j S P 1 41 61 7' 4' 7' 8' a, a. 91 01 10' 4' 10, g. 13' 8' 14' 0' 14' 0' 14' D' L> 4' 3' 7' 3' 71 7' 81 71 al 111 10, 31 10, 81 13' 6' 141 0. —14-' D' 14' 0' 3 4' 2' 6' D' 6' 4' 71 111 8' 6' 10' 2' 10' 7' 12, 51 13' 4' 14' 0' 14' 111 DFL__Atud 4' 2' 6' D' 6' 4- 71 111 8' 6' 10' 2' 10' 7' 12, 51 13' 4' 14' D' 14' 0' d Standard 4' 0' 5' 3' 5' 7' 7' 0. 7' 6' 9' 6' 10, 21 111 01 11' ID' 14' D' 14' 0' U SPF 01 / #2 4' 11 8' 4' 81 8. 91 10, 10' 3' Ill 81 12, 21 14' 0' 14' 0' 141 D' 14' 01 3 4' 8' BI 1. 8' 8' 1 9' 8, 10' V 1 11' 7' 12' 1' 141 01 14' 0. 14' D' 14' 0' o) U 0 HF Stud 41 8- 81 1. 8' 6' 1 9' 8' 10, 11 11' 7' 12, 11 141 01 14' 0' 14' D' 14' D'_ Standard 4' S' 6' 11' 71 5' 91 3' 91 Ill Ill 71 12' 1' 14' 0' 14' 01 14' D- 14' 0' 1 5' 11 81 5- 81 9. 91 ill 10' 4' Ill 10, 121 41 14' D' 141 01 141 01 141 01 l,.D S P 2 41 111 81 41 91 10, 101 31 ill a, 141 DI 14' D' 141 01 141 111 3 41 91 7' 4' 71 91 91 91 10, 21 Ill 81 12, 11 141 01 141 01 141 01 141 01 DF Stud 4' 9' 7' 4' 7' 9'_ 9' 9' 10, 21 Ill 81-- 12' 1' T4—'—V--- F4 14' 0' 14' _0' Standard 1 41 81 61 51 61 IDI 81 71 91 a, Ill 71 121 11 131 61 141 01 14101 141 01 1 / #2 5' 5- 91 21 91 61 10, 10' 11' 3' 1 11' 8' 13' 5' 14' D' 14' 111 141 01 141 01 U o SPF HF 3 7 —1, 9, 0- 91 4' 10, 8;. ill 11 12, 91 13' 3' 14' 0' 141 01 14' D' 14' 0' Stud 5' 1- 91 0. 9' 4- 1 10' 8' Ill 11 12' 9' 13' 3' 14' 0' 14' 0' 14' D' 14' 0;'_ 51 11 81 0. Standard 8' 6' 10, 81 Ill 11 12, 91 13' 3'_ 14' 0' 14' 01 14' 0' 14' 0' X S P 1 51 8. 9' 3' 9' 81 10, Ill 11' 4' 13' D' 13' 6' 14' 0' 141 0' 14' 0' 14' 0' 2 5' 5' 9' 2' 91 61 10, 10, 11' 3' 12, ill 13' 5' 14' 0' 14' 0' 14' 0' 14' D' 3 1 2 91 0. 10, 9. Ill a, 12, 10, 13' 4' 14' 0' 141 01 14' 0' 23; :; 14' 0' ku DFL St d 52; 5; 91 0. 10, 9' 1 ill a- 12' 10. 131 41 141 01 14' 0' 14' 01 14' 01I—st-, Ulrcl 5' 1- 7' 5' 7' 11' 9' 111 1 10' 7' 79112 E; 3 1 1 14' 01 14' 0- 14' 0' 14' 0' Bracing Group Species and Grades, Group A, Pruce- ne-Fir Hem -Fir 1 #1 / #2 IStandard 1 #2 1 Stu 1 #3 1 Stud 1 1 #3 IStand9ard Duo (is Fir -Larch Southern Plnewwls 3 #3 i—tual Stud Group B, Hen -Fir 1 ki Btr Dpuqlas Fir -Larch Southern Pinewsw 2 Ix4 Braces shall be SRB (Stpess-Rated BoaroD. 4wwFor lx4 So. Pine use only Industrial or Industrial 45 Stress -Rated Boards. Gr up B11valuesmaybeusedwiththesegrades. babLe Truss Detalt Notes: Wind Load deflection criterion Is L/240, Provide uplift connections for 55 ptf over continuous bearing (5 psf TC Dead Load), Goble end supports load from 4' V outtookers with 2' 0' overhang, or 12' plywood overhang. wl;;." i IY_ Attach ILI braces with 10d (0.12Wx3,0' min> nails. ble Truss X For Q> ILI brace. space nails at 2' oc. a In 18' end zones and 4' o.c. between zones, K)KFw (2) ILI braces. space malts at 3' o.c. Diagonal brace option, In 19' end zones and S' o.c. between zones. vertical length may be T doubted when diagonal is, 3K 'L' bracing must be a minimum of 80% of web brace Is useoL Connect member length. diagonal brace for 450# ILI J_ at each end, Max web Br ce Gable Vertical. Plate Sizes total length Is 14 K I Vertical Lenoth No SpliceWX 2x4 DF -L *2 or Less than 41 01 IX4 or 2X3 1Z better diagonal T_ iGreater than 4' 01 X4 I Vertical length shown brace) single in table above. 1451* or double cut )K as shown) at n I Irl 4 Refer to common truss design for upper end. l_i u "a] u -q u Ill V j'r IL_peaLk, splice, and heel plates. 77 7 4 1 / A Refer to the Building Designer for conditionsIng Connect d1agon.T_.t__ low not addressed by this detail. Refer to chart a4e a a e tp. amidpointofverticalwell. '44d WARNDX3- READ AND FOLLOW ALL NOTES ON TMS DMVING a, REF ASCE7-10—GABI4015DrORTANT— FURNISH TMS DRAWFINCi To ALL cowntAcTaws ucLullm ThE =TmLEM f Truss— require extreme car* In fabricatimil, ho"Imo, shipping, lnst*LLW* and braeft, Refer to I oil ow the Latest edition of SCSI (BuIllingi Component Safety Information, by TPI and SBCAi for s*ffty 0 DATE 10/01/14 or. formthil, these funi tlom Installers shalt provide temporary brachil per BC .16 untcxtsic&mstp ciborthteorwiWseI too chord sl how property attached st—twat ii W* and bottom we it hw property tt..hd IgW —Kini). Loc.tlom. shown fair p—mont L.t.ral ... train* of DRWG A14015ENC101014 shall have lor—InG installed per BCSI sect$ons 23, B7 or DID, as appilc6ble. Apply plates to ch f.c wiaMpositlonasshoemaboveamidontheJointDetails, unless no-ttal otherwise. LJPD [F Rf. 4,-t. d-shl l"A-Z far tandard plot. poisitions. 10A&N OR\)- Alpine, . alllWon of ITV B.Noing Components Group I- halt not be —ponsibl. far my t f 44 AN rrw CC`k4PAW this dr—kno, ary failure to bLAd the tr"s in conformance with ANSI/TPI 1, or far handling, aaawasiell"' Inst.1l.tion & birachv of t—sts. TOT. LD. 60 PSF 13723 Riverport Dr— . A wiral an this d -.*V or cliver PM listing this drawling, hx4diastirs .—ptamor of prof I f2M-6=ponsIkAIU.w==y d.% shown, = I= M and —,a* this dra Sui e 2DO t.— is f B.R*V =YxTPI SOC2. Maryland Heights, MO 63D43 For — Information see this, jobS general notes page and these web sites- ALPINE- —.1pheltwzomi TPI. wwwApinilt.o,ll) SBC& —..t1Clnds1ry—Q) Icc. -kCsaftoro 07/05/20 8 AX. SPACING 24.0' CLR Reinf orcing Member Substitution T-Reinf orcement This detail. Is to be used when a Continuous Lateral Restraint (CLR) r T-Reinf. Is specified on a truss design but an alternative web L-Reinf orcementi or reinforcement method Is desired. L-ReIrif. Notes: This detail Is only applicable for changing the specified CLR shown on single ply seated designs to T -reinforcement or L-relnforecement or scab reinforcement. Alternative reinforcement specified In chart below may be conservative. For minimum alternative reinforcement, re -run design with appropriate reinforcement type. Web Member Specified CLR Alternative ReInforecement Size Restraint T- or L- Reinf. Scab Reinf. 2x3 or 2x4 I row 2x4 1-2x4 2x3 or 2x4 2 rows 2X6 2-2x4 2xG I row 2x4 1-2x6 2x6 2 rows 2x6 2-2x4GO 2x8 I row 2X6 1-2XB 2x8 2 rows 2x6 2-2x6OK> T -reinforcement, L -reinforcement, or scab reinforcement to be same species and grade or better than web member unless specified otherwise on Engineer's sealed design. 00 Center scab on wide face of web. Apply (1) scab to each face of web. Apply to either side of web narrow face. Attach with 10d (0,128'x3.0',min) nails at 6' o.c. Reinforcing member Is a minimum 80% of web member length. Scab Reinf orcement: Apply sccLb(s> to wide face of web, No more than (1> scab per face. Attach with 10d (0.128'x3.0',min) nails at 6' o.c. Reinforcing member Is a minimum 80% of web member length. Scab 7 T-ReInf. L-Reinf. WARNMliew RM AM FOLUW ALL NIMS ON MS DRAWDO - Tt*a PSF REF CLR Subst. D*MUANT rURNM TMS ]RAWING M ALL COMMCM112 DCLOM TK INST IT,-... r.*Ae w.t care In fabricatkio, ho"Ino, shippino, ImtolUno and br 5 . I /* follow the latest edition of BCSI UkAding Conp—d Safety lnf tlan, by TPI a ;n—., :1 Is D PSF DATE 10/01/14 practices prior to perforp*V these f—cti— linstalLers shall provide terporary brac Per III L PSF DRWG BRCLBSUB1014Lk-Aess ted otherwise, top chord shall how properly attached StriiiCtiuiral Sht6thkV =il tzwr. 0 d we shall =, properly attached far p—ront kater l.t— . 7ATE L33, ho" :ttr.,Int of Iseach Opxectj e. shall have :,Qchg iist6ted per X1 =*131-7VIII01 as 6WIcabL Apply a —d tion as sh— ba- —d — the J.It Details, -is.. —t.d otherwise. '# 00 PSF R:1*.,-to d .. = 16DA-Z fair t—l-d plot. p..Itl—. P. 10 Atpk., . a1hislon of ITW IhAdbV Cm.—M. G—p I— shall not be —p—lbl. for " d-lti., f-31. to R010 AN rrwCX)MPANY this drawft, QrW fakwe to bu d the triiass In conforname with ANSI/TPI 1, or fair hurdling, shopli'll), LD. PSF talla t L brackV of truss:.. A sa= this drawft or co—ir ~ tistft this dra,619, b1diCatrit aCceptance Of PrOf"91 1 13723 Riverport Drive =11 *Z-Zlznpo.rft jtY. = sho— = I=MP,7yilandalfg. Iof Oft dra N D U 1R.. FF A C. i e 200 S*cZ. M atryland Heights, MO 63043 ALP, F mor. linf—tl— ... this Job'. C—L —t.e page ..d these web It— 11a NErwww.alpl ettwzoni TPI- wreApinst.orlij SBC& —sbcWwIustry.or0) IM wwwJccsaft o ;m 97R 07/05/2 19 SPACING Gable Detail Fnr I Pt-iri Vpr+irnl_ Gobte Truss Plate Sizes T' ReinforcingMember Go bte Truss ppropriate Alpine gable detail for e sizes for vertical studs, Engineered truss design for peak, b, and heel plates. vertical plates overlap, use a Ae that covers the total area of topped plates to span the web. el 2 2X4 *2X8 rrovicie connections i:or uplift specified on the engineered truss design. Attach each 'T' reinforcing member with End Driven Nalls, 10d Common (0.148'x 3.',mln) Nails at 4' o.c. plus 0 nails In the top and bottom chords, Toenalled Nails, 10d Common (0.l48'x3',m1n> Toenalts at 4' o.c. plus 4) toenalls In the top and bottom chords. This detaft to be used with the appropriate Alpine gable detail for ASCE wind load. ASCE 7-05 Gable Detall. Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 & ASCE 7-16 Gable Detail Drawings A11515ENCIODIIB, A12015ENC100118, A14015ENC100118, A16015ENCI00119, A18015ENC100118, A20015ENC100118, A20DI51ENDI00118, A2001 A11530ENCID0118, A1203DENCIDDIIB, A14030ENCI00118, 01 A18030ENCI00118, A20030ENC1100118, A20030ENDIDO 3 00 S11515ENC100118, S12015ENCI00118, S14015ENC10 S18015ENCI00118, S20015ENCIOD118, S20015EN S11530ENCI00118, S12D30ENC100118, S1403DE SIBODENC100118, S20030ENC10011B, S20(13 DI S2 ED10 18 See appropriate Alpine gable detail for moLxl_ In u r4A forc . gabi - T' Reinforcement Attachment Detail T' Reinforcing 'T' Reinforcing Member Member Toe -nail Or End-nalt To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detail). Maximum allowable 'T' reinforced gable vertical length Is 14' from top to bottom chord. T' reinforcing member materlat must match size, specle, and grade of the 'L' reinforcing member, V/eb Length Increase w/ 'T' Brace IT' Reinf, 'T' Mbr, Size Increase 2x4 30 % Example, 2x6 20 X ASCE 7-10 Wind Speed = 12D mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Verticat = 24'o.c. SP #3 T' Reinforcing Member Size = 2x4 T' Brace Increase (From Above) = 30% = 1.30 W 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length wi 1.30 x 8' 7' = 11' 2' WARNIMM" RCAD ANII FOLLOW ALL NaTu ON THIS DRAVM REF LET -IN VERTANT" FURNISH THIS 11RAWING TO ALL CONTRACTORS MMLMMG THE Trusses require extreme care in fabricating, handling, shipping. Installing and br f allow the latest edition of RCSI (Building Component Safety Information, by TPI and SRCA) for s 0 DATE 01/02/201B p'a't t rt tk 41 WKINPORT we Installers &halt provide temporary bracing T lees prior to perfo-iing these functions. t XE 0 Untess noted otherwise, top chord shatt have property attached structural she& ..,r4i.-d.boi -mf Vor o+ st int ? 10 h*tl have a property attached rigid ceiling. L -tions shown for permanent later 'o DRWG GBLLETIND118 rghot[ have bracing Installed per RCSI sections 23, D7 or 1110, as applicable. Apply ptates to each f@ o :f.truss and position as shown above and on the Joint Details, unless noted othersise. -N R r to drawings ISDA-Z far stand -I ptat. positions. *,t 0 46. .010 e-. 0,WILCoMpAWAlpine, a division of ITV Ruildby Components Group Inc. sholl not be responsible far ant deviation f- ,fYANrrw ;" . this drawing, any failure to bull the truss In conformance with ANSI/TPI 1, or far hand. no, shipping, Installation & bracing of trusses. MAX. TOT, LD. 60 PSF A seat an this atrawwo - cover page Ut1mg this d'a Indicates acceptance of mme 13723 Riverport Dnve ;rq*werft responsiblift.soWy far the de shown. %-. suitability and use of t DUR. FAC, ANY S.it.,200 or any structure Is t responsibility of% bAding Designer W ANSLITPI I SecZ. #0 278 07/05/2018FormoreInformationseethisjob's general notes page and these web sitestM.ry -d Height., MO 63043 ALPINE, www.alpinaltw.com) TPI, wwwApInst.org) SRCA, w-slocindustry.oraj IM wwwJccsofe.o,g MAX. SPACING 24.0' Ir Product Approval qpecification Form g Permit # Project Location Address N ( 00- Scm()rdn -C, As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.or, q. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Florida Approval # Description (include decimal) 1. Exterior Doors 113 - a % N S7. 1'— Swinging OCISWS 44 014 9&t:2(K- Sliding Sectional Roll Up I -I . 0 Automatic Other 2. Windows C>(=( ?-. %Z - Single Hung 9649r-09 Horizontal Slider Casement Double Hung Fixed ?G: Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 or Category/ Subcategory Manufacturer Product Description Florida Approval # including decimal) 3. Panel Walls Siding Soffits CU e__s Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles M CU) 0 (A -U C, 15 - 0-7 2,1 Underlayments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal) 5. Shutters Accordion Bahama Colonial Roll up Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Please Print) June 2014